HomeMy WebLinkAbout37915 Eiland BlvdCHANGE OWNERSHIP OF AN EXISTING RESTAURANT GOLDEN PANDA RESTAURANT 37915 EILAND BLVD, ZEPHYRHILLS, FL 33542 `.SCALE: N.T.S. SHEET INDEX 1 01 COVER SHEET 2 D1 DEMOLITION PLAN 3 Al FLOOR PLAN 4 Al-1 EQUIPMENT PLAN 5 A2 LIFE SAFETY PLAN 6 A3 REFLECTED CEILING PLAN 7 A4 ARCHITECTURAL DETAIL 8 A5 ARCHITECTURAL DETAIL 9 M l HVAC PLAN 10 M2 ROOF TOP EQUIPMENT PLAN 11 M3 IHOOD DETAIL 12 E1 ELECTRICAL PLAN 13 E2 LIGHTING PLAN 14 E3 ELECTRICAL PANEL SCHEDULE 15 P1 SANITARY PLAN 16 P2 WATER SUPPLY PLAN 17 P3 PLUMBING RISER 18 P4 GAS RISER 19 P5 PLUMBING DETAIL CODE CLASSIFICATION: 2023 FLORIDA BUILDING CODE -BUILDING (8TH EDITION) 2023 FLORIDA BUILDING CODE -EXISTING BUILDING (8TH EDITION) 2023 FLORIDA BUILDING CODE -ACCESSIBILITY (8TH EDITION) 2023 FLORIDA BUILDING CODE -ENERGY CONSERVATION (8TH EDITION) 2023 FLORIDA BUILDING CODE -MECHANICAL (8TH EDITION) 2023 FLORIDA BUILDING CODE -FUEL GAS (8TH EDITION) 2023 FLORIDA BUILDING CODE -PLUMBING (8TH EDITION) 2023 FLORIDA FIRE PREVENTION CODE (8TH EDITION) 2020 NATIONAL ELECTRICAL CODE PROJECT DATA: 1. TOTAL SQUARE FOOTAGE: 2. CONSTRUCTION TYPE: 3. USE/OCCUPANCY CLASSIFICATION: 4. FIRE SPRINKLER SYSTEMS: 5. BUILDING OCCUPANCY (PER 2023 5,600 SQ.FT. III-B ASSEMBLY(A-II) NO FLORIDA BUILDING CODE(8TH EDITION)) OCCUPANT LOAD(PER FBC 1004.5) AREA PER CALCULATED SEAT SPACE DESCRIPTION SEATING TYPE AREA OCCUPANT OCCUPANT PROVIDED LOAD KITCHEN& SERVICE AREA 1451 SF 200 7 BUSINESS AREA(BUFFET AREA, RECEPTION) 1007 SF 150 7 BOOTH 168 LF 18" 112 84 DINING AREA UNFIXED TABLE 1504 SF 15 100 76 STORAGE 132 SF 300 1 WAITING AREA 42 SF 7 6 TOTAL 233 160 6. NUMBER OF EXITS (FBC SECTION 1006.3) REQUIRED: 2 PROVIDED: 4 7. EGRESS WIDTH (FBC SECTION 1005.1) EXIT CAPACITY CALCULATIONS (DOORS) 233 X 0.25 (UNSPRINKLED)=58.25" REQUIRED MAIN EXIT PROVIDED: 64" > 29.125" (58.25"/2) (50% OF THE REQUIRED CAPACITY) OTHER EXITS PROVIDED: 128" > 29.125" (58.25"/2) (50% OF THE REQUIRED CAPACITY) TOTAL EXIT PROVIDED: 192" > 58.25" REQUIRED B. MAXIMUM EXIT ACCESS TRAVEL DISTANCE (FBC SECTION 1016.2) MAX. TRAVEL DISTANCE ALLOWABLE MAX. TRAVEL DISTANCE TO FRONT 38'-10" 80'-5"(<200') 200'-0" TO SIDE 55'-1 1 " TO BACK 47'-7" DEFERRED SUBMITTAL: 1. HOOD FIRE SUPPRESSION: HOOD FIRE SUPPRESSION CONTRACTOR SHALL SUBMIT FIRE SUPPRESSION SHOP DRAWING' UNDER SEPARATE PERMIT. FIRE SAFETY NOTE: 1. FIRE EXTINGUISHER, PER 2019 N.F.P.A. #10. 2. KITCHEN SUPPRESSION SYSTEM PROTECTION, PER APPLICABLE, - PROVISIONS 2018 N.F.P.A. #96, AS MODIFIED. FINISH NOTES: 1. INTERIOR FINISH SHALL COMPLY WITH 2O23 FBC 801.2 & 2. EXIT ENCLOSURES AND EXIT PASSAGEWAYS: CLASS B CORRIDOR: CLASS B ROOMS AND ENCLOSED SPACES: CLASS C CLASS A: FLAME SPREAD 0-25, SMOKE DEVELOPED 0-450 CLASS B: FLAME SPREAD 26-75, SMOKE DEVELOPED 0-450 CLASS C: FLAME SPREAD 76-200, SMOKE DEVELOPED 0-450 3. ALL DECORATIVE MATERIALS SUSPENDED FROM WALLS OR 801.4 & 806. 4. WALL AND CEILING FINISH SHOULD MEET CLASS A, B, C, 5. FLOOR FINISH SHALL MEET EITHER: A) ASTM D 2859 FOR MATERIALS OR B) HAS A MINIMUM CRITICAL RADIANT FLUX CARPET FLOORING. PER NFPA. 101:12.3.3.5.3. 801 .3, 803 AND 804. CEILINGS SHALL MEET FBC PER NFPA 101:12.3.3.3 CARPET AND CARPET LIKE OF .1 W/CM2 FOR NON 6. FURNISHINGS, DECORATIONS AND SCENERY SHALL MEET NFPA.101:12.7.4 REVIEW DATE 5 CITY OF ZEPHYRHILLS FIRE AND LIFE SAFETY EXAMINERZ4�___ ALL WORK SHALL COMPLY WITH NFFA CODES AND STANDARDS GENERAL NOTES: I 3 m 5 6. 7. 8. 9. 10 11 THE CONTRACTOR SHALL FIELD VERIFY ALL CONDITIONS AND DIMENSIONS PRIOR TO ANY WORK AND SHALL BE RESPONSIBLE FOR ALL WORK AND MATERIALS INCLUDING THAT FURNISHED BY SUBCONTRACTORS. DIMENSIONS TAKE PRECEDENCE OVER DRAWINGS; DO NOT SCALE DRAWINGS TO DETERMINE ANY LOCATION. THE OWNER SHALL BE NOTIFIED IF ANY DISCREPANCY OCCURS PRIOR TO CONTINUING WITH WORK. ALL CONSTRUCTION SHALL COMPLY WITH THE APPLICABLE BUILDING CODES AND LOCAL_ RESTRICTIONS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO LOCATE ALL EXISTING MECHANICAL AND ELECTRICAL SERVICES AND DISTRIBUTION SYSTEMS WHETHER SHOWN OR NOT, AND TO PROTECT THEM FROM DAMAGE. THE CONTRACTOR SHALL BEAR ALL EXPENSE OR REPAIR OR REPLACEMENT OF UTILITIES OR OTHER PROPERTY DAMAGED BY OPERATIONS IN CONJUNCTION WITH THE PERFORMANCE OF THE WORK. ALL WORK SHALL BE ACCOMPLISHED WITH QUALITY WORKMANSHIP OF THE HIGHEST INDUSTRY STANDARDS. ALL MATERIALS SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURERS INSTRUCTIONS AND RECOMMENDATIONS. MATERIALS AND METHODS SHALL CONFORM TO THE APPROPRIATE NATIONAL TRADE BOOKS; I.E. TILE COUNCIL OF AMERICA, HANDBOOK FOR CERAMIC TILE INSTALLATION; ARCHITECTURAL WOODWORK INSTITUTE, "QUALITY STANDARDS." ETC. THE CONTRACTOR SHALL BE RESPONSIBLE FOR JOB SAFETY, AND SHALL TAKE ALL NECESSARY PRECAUTIONS TO ENSURE SAFETY OF WORKERS AND OCCUPANTS AT ALL TIMES. ALL ELECTRICAL, MECHANICAL, AND PLUMBING WORK SHALL CONFORM TO STATE AND LOCAL REQUIREMENTS. REMODEL WORK SHALL NOT OBSTRUCT, OR CAUSE TO BE INOPERATIVE, EXISTING FIRE PROTECTION SYSTEMS. MODIFICATION TO FIRE PROTECTION SYSTEMS SHALL BE PERFORMED BY A FIRE PROTECTION CONTRACTOR, WHO SHALL OBTAIN A PERMIT FROM FIRE LOSS MANAGEMENT PRIOR TO WORK. DECORATIVE MATERIALS, DRAPES, HANGINGS, ETC., SHALL BE NON FLAMMABLE OR FLAME -PROOF PER STATE FIRE MARSHALL REQUIREMENTS. MINIMUM FLAME SPREAD CLASSIFICATION OF INTERIOR FINISH SHALL CONFORM TO THE BUILDING CODE AND LOCAL GOVERNING BUILDING CODES/ORDINANCES. FIRE SUPPRESSION CONTRACTOR SHALL SUBMIT SEPARATE PERMIT APPLICATION FOR APPROVAL. PLUMBING FIXTURE CALCULATION (PER FBCP 403.1) SPACE DESCRIPTION ASSEMBLY-2(RESTAURANT) TOTAL OCCUPANCY LOAD 233 SEX MALE 117 FEMALE 117 WATER CLOSET REQUIREMENT MALE 75 PER 1 FEMALE 75 PER 1 REQUIRED 2 2 PROVIDED WATER CLOSET 2 2 URINAL 1 LAVATORY REQUIREMENT MALE 1 PER 100 FEMALE 1 PER 100 REQUIRED 2 2 PROVIDED 3 3 SERVICE SINK REQUIREMENT 1 REQUIRED 1 PROVIDED 1 REVIEW DATE: - 1e^2T- CITY OF ZEPHYRHILL BUILDING OFFICIALii�� ALL WORK SHALL COMPLY WITH PREVAILING CODES FLORIDA BUILDING CODE, NATIONAL ELECTRIC CODE, AND THE CITY OF ZEPHYRHILLS ORDINANCES p Zuj of�Li U O o w (n> w CD z Q o w m CD ^ u J O Q �¢Nz�o Z mZ�CDC,Of O M M L-j m o in w oop Q¢cn 0 cn mQw wwZ>- U 000�CQ z �J000 CD w ¢ .,� i p :p :� Q 0: Z.. �..> z •. �b �w •. .•�F.• z Q 0 Q W 0 J CIA �n Q z o M cn � cn z o M Lu Lu C� w W ►-� w w w w L7 M N cn U REVISION 1 1 L 1 3 4 1 s 1 6 1 7 PROJECT TYRE: RENOVATION SCALE AS SHOWN ISSUED DATE: 03_08-2024 DRAWN BY: A. FEN G CHECKED BY: A.LIANG SHEET 0 _ 1. __ I I ! - 1 D_AOLIT ON PLAN SC,.I ,E: 3/ 16"=1'-0" DEI, ;lLITION KEYED NOTES: I ) 1. REMOVE EXISTING PARTITION AND COUNTERS. TO REMOVE UNUSED ELECTRICAL WIRING BACK TO NEAREST JUNCTION BOX. 2. TO REMOVE EXISTING HOOD SYSTEM IN THE KITCHEN AREA 3. TO DEMOLISH EXISTING RESTROOM. 4� POWER PANELS TO BE REMAINED. 5.. NO STRUCTURAL WORK. 6. ACCUMULATION OF AMBULATION OF COMBUSTIBLE WASTE MATERIAL, DUST, AND DEBRIS SHALL BE REMOVED FROM THE STRUCTURE AND ITS IMMEDIATE VICINITY AT THE END OF EACH WORK SHIFT OR MORE FREQUENTLY AS NECESSARY FOR SAFE OPERATIONS. NFPA 1:16.2.2.1 7.. DURING DEMOLITION EXITS AND FIRE SAFETY EQUIPMENTS SHALL BE CLEARLY VISIBLE AND UNOBSTRUCTED. 8. EXISTING CEILING SYSTEM TO BE REMAINED 9, ANY STRUCTURAL WORK AND THE PROPOSED TEMPORARY BRACING TO MAINTAIN THE STRUCTURAL INTEGRITY DURING CONSTRUCTION. GENERAL DEMOLITION NOTE: -- - - --- --X 1. THE FOLLOWING REQUIREMENTS FOR DEMOLITION, CUTTING AND PATCHING APPLY TO ALL WORK WHICH IS ALTERED, WHETHER SUCH WORK IS NEW, EXISTING, RENOVATED OR REPLACED: 2. ASBESTOS SURVEY AND ABATEMENT: PRIOR TO DEMOLITION, CUTTING OR PATCHING WORK, ENGAGE A Ir LICENSED ASBESTOS CONTRACTOR TO PERFORM AN ASBESTOS SURVEY, WHICH IDENTIFIES SPECIFIC LOCATIONS WHERE ASBESTOS CONTAINING MATERIALS ARE FOUND, AND WHICH PRESCRIBES SPECIFIC Z o 0 ACTIONS REQUIRED FOR ABATEMENT. ENGAGE A LICENSED ASBESTOS ABATEMENT CONTRACTOR TO U ¢ a o � Q wUS W REMOVE OR ENCAPSULATE ALL ASBESTOS CONTAINING MATERIALS, ACCORDING TO THE w Z "Z `�' w AnoN I RECOMMENDATIONS OF THE ASBESTOS CONSULTANT. WHERE ASBESTOS CONTAINING MATERIALS ARE �'< � W w o Q m o 37wmi WALK—IN uFRMUt ENCAPSULATED IN THE BUILDING, PROVIDE THE OWNER WITH A DETAILED DESCRIPTION OF ALL N w `�'� Z >-Q-z� REMAINING MATERIALS, INCLUDING LOCATIONS, APPROXIMATE QUALITIES, AND METHODS OF ECAPSULATEDV p o W °' � �- N W AND INSTRUCTIONS FOR NOT DISTURBING THE ENCAPSULTED MATERIALS. Ol M M m o �' o o = W M--i O M �' ¢ WwwQw "o d' U 000�v>¢ • • • CD 3. PRIOR TO DEMOLITION, CUTTING AND PATCHING, THE CONTRACTOR SHALL LOCATE AND DISCONNECT Z z CD UTILITY SERVICES AND ELECTRICAL / MECHANICAL SYSTEMS, OR TEMPORARILY CAP OFF SUCH SERVICES w 00 V, o , 3 TO THE AFFECTED AREAS. GIVE NOTICE TO, a:Z = Z I.-0 AND COORDINATE WITH UTILITY COMPANIES. OBTAIN w p 00 WRITTEN APPROVAL FROM, AND COOPERATE WITH OTHER PARTIES WHO MAY BE AFFECTED BY A L7 a w 00 LN INTERRUPTION OF SERVICES. o 4. CLEARLY MARK THE AREAS AND LIMITS OF DEMOLITION, CUTTING AND PATCHING. IF FEASIBLE, 61*11111810, PRE—CUT THE LINE OF SEPARATION BETWEEN AREAS OF DEMOLITION AND AREAS TO BE PRESERVED. •. w x\` EXISTING ,'��� `G ,, .......:CL �/��/ .,. WALK—IN DEMOLITION AND CUTTING TECHNIQUES WHICH ARE LEAST LIKELY TO DAMAGE SURROUNDING OR �Q:•'' COMM - ADJOINING WORK. WHERE FEASIBLE, USE HAND TOOLS AND SMALL POWER TOOLS THAT ARE DESIGNED ; �:�, 0, U- �'•;v>; FOR SAWING AND GRINDING, NOT HAMMERING OR CHOPPING. DO NOT USE EXPLOSIVES. r2 Lu �� H 0: z x Q • - J 5. STRUCTURAL REQUIREMENTS: DO NOT CUT AND PATCH STRUCTURAL WORK IN A MANNER WHICH WILL ti:� z° U) �; o REDUCE LOAD -CARRYING CAPACITY OR LOAD -DEFLECTION RATIO. WHERE STRUCTURAL WORK MUST BE w •j•.,,.. ..,,.•'�`'',•` 2 1 CUT PROVIDE ADEQUATE TEMPORARY SUPPORT BRACING AND/OR SHORING TO RESIST VERTICAL ''•b Rest04 LATERAL AND DYNAMIC LOADS IN THE ENTIRE TRIBUTARY AREA OF THE AFFECTED STRUCTURAL '� EXISTING I ( / �mNc MEMBERS. WHERE REQUIRED, ENGAGE A LICENSED STRUCTURAL ENGINEER TO DESIGN SHORING / BUFFET TAB E / I I BRACING SYSTEMS AND JOINT OR CONNECTION DETAILS. --- - 6. OPERATIONAL AND SAFETY LIMITATIONS: DO NOT CUT AND PATCH OPERATIONAL ELEMENTS OR SAFETY ol RELATED COMPONENTS IN A MANNER WHICH WILL REDUCE INTENDED PERFORMANCE OR SAFETY FACTOR, OR WHICH WILL RESULT IN INCREASED MAINTENANCE OR REDUCED OPERATIONAL LIFE. -- -' 7. VISUAL REQUIREMENTS: DO NOT CUT AND PATCH WORK IN A MANNER WHICH WILL RESULT IN lo LESSENING OF THE AESTHETIC QUALITIES OF THE BUILDING OR SITE, OR THAT WILL RESULT IN VISUAL ' EVIDENCE OF CUT AND PATCH WORK. WHERE REQUIRED, EXTEND FINISH MATERIALS OVER ENTIRE UNBROKEN SURFACE AREAS AFFECTED BY CUT AND PATCH WORK. REMOVE AND REPLACE CUT AND 1 PATCH WORK WHICH DOES NOT MEET VISUAL REQUIREMENTS. o o Ix 1 lo I 8. PROTECTION: PROTECT OTHER WORK DURING CUTTING AND PATCHING OPERATIONS TO PREVENT DAMAGE. PROVIDE PROTECTION OF ALL WORK FROM ADVERSE WEATHER CONDITIONS. WHERE OPENINGS ARE CREATED IN ROOF OR EXTERIOR WALLS, PROVIDE TEMPORARY ENCLOSURE OF SUCH OPENINGS ON A DAILY BASIS, AND WHENEVER ADVERSE WEATHER THREATENS OR EXISTS. XII ELECTRICAL DEMOLITION NOTES 1. THE CONTRACTOR SHALL REMOVE ALL UNUSED AND ABANDONED WIRING AND CABLING FROM THE r CEILING THAT ISN'T LABELED FOR FUTURE USE AS REQUIRED BY THE NEC. THIS SHALL INCLUDE BUT �I r IS NOT LIMITED TO FIRE ALARM, POWER, SECURITY, CONTROLS, DATA, TELEPHONE, A/C ETC. 2.CIRCUITS MADE SPARE SHALL BE UPDATED ON PANEL SCHEDULES. DIRECTORY CARDS SHALL BE REPLACED WITH NEW TYPED DIRECTORIES, INCLUDING ALL NEW LOADS IN ADDITION TO SPARES.Lj HAND -MARKED NOTES WILL NOT BE ACCEPTED. 3.CARE SHALL BE TAKEN TO RELOCATE ALL EXISTING EQUIPMENT THAT IS BEING MOVED BUT REMAINING - :I AFTER COMPLETION OF WORK. THE CONTRACTOR SHALL BE RESPONSIBLE TO KEEP ALL EXISTING TO REMAIN OR RELOCATED EQUIPMENT AT THE SAME LEVEL OF FUNCTIONALITY FROM THE ACCEPTANCE OF THE CONTRACT OF FINAL COMPLETION. ANY DAMAGE OR LOSS OF FUNCTIONALITY SHALL BE REMEDIED BY THE CONTRACTOR AT NO ADDITIONAL EXPENSE TO THE OWNER. 4.EQUIPMENT INDICATED TO BE REMOVED AND NOT RE -USED SHALL REMAIN THE PROPERTY OF THE OWNER AND RETURNED OR STORED AS DIRECTED. 5.CONDUITS AND RACEWAY SYSTEMS MAY BE ABANDONED WHERE CONCEALED HOWEVER SHALL BE ^ M o REMOVED WHERE EXPOSED. REMOVED OUTLETS SHALL BE PROVIDED WITH BLANK COVERS, COLOR PER A M THE ARCHITECT'S DIRECTION. a z 1 o 6.EXISTING RACEWAYS AND WIRING ARE ALLOWED TO BE RE -USED PROVIDED THEY MEET THE A ^ SPECIFICATIONS FOR THE NEW SYSTEM(S). Z A ,.un.� z 7.ALL OUTAGES SHALL BE COORDINATED WITH THE OWNER. THE CONTRACTOR SHALL PLAN TO MINIMIZE ALL OUTAGES. Z &CIRCUITS SHALL STAY FUNCTIONAL WHERE DEVICES/FIXTURES ARE BEING DEMOLISHED THAT SHARE A 0 COMMON CIRCUIT WITH DEVICES/FIXTURES THAT ARE TO REMAIN. WIRING SHALL BE REMOVED AS FAR AS POSSIBLE WHILE MAINTAINING EXISTING TO REMAIN OPERATION. o O W W W 9.THE CONTRACTORS SHALL REMOVE ALL EXISTING ELECTRICAL EQUIPMENT NOT REUSED OR NOT cn N N ❑ NECESSARY FOR THE COMPLETION OF THIS PROJECT. REVISION 1 1 2 3 4 5 6 7 PROJECT TYPE: RENOVATION SCALE AS SHOWN ISSUED DATE: 03_08_2024 DRAWN BY: A•FENG CHECKED BY: A. LI AN G SHEET I I---- _ I _I 11 1 --]-_ _ I - f -- L- - 1 42' 7'-8 9'-7" 10, 8' f, —3 4'-2—, Mll 25' —3') EXISTING STORAGE x i x EXISTING 1 MECH ROOM x\ w1 _ II D3 D3 \� I v I) O7 CD — �\ 1 -9 � I I EXISTING CDm CD I KITCHEN D D D7 CD 00 00 f ff D� m m m — 8 .--- ,� I m x � ADA � N COUNTER-----------T---I Xj x I I f 15f S.S. TABLE j j I I I W m I I co I I x 6' W1 CONVECTION —7 N f f, �OVENx 4 3n I I I 1 .. co I I I I I I I w i I Ln ❑- NI x x -- I - I Q I xll I I m I - - --� - - In Ui L- ------ yl I -) I I N I I 1 x I I I I (�,, I I �yL-4 I I I �lz A E A E ^ i i Ld Lf71 c� X, cV Ew I i i Q I x I I Fm— /\����I I I I (n I I I I N I ------- --- O I I n I V� I I N rjL i I I ------------ { III I-� BUFFET illA E 1 u I TABLE I 1 m I I ------------ I I ~ N x I I cn I 1 �I � O I I w1 J - FE 0 0 0 wi I I I I I II � WAITRESS I I _ w - I STATION �___� 1 00 — --------- �-I x MI I -- x� --If [H .11 1" ---xl xxxx�xxx`xxx_ -x - D2 42' 71-81f 6'-8ff 21'-6f1 Fl.-.-)OR PLAN_ 78'-10" TAG LEGENDS D# DOOR TYPE TAGS(SCHEDULE SEE A3) W# WALL TYPE TAGS(DETAIL SEE M) WALL TYPE SCHEDULE - — - ===3 EXISTING FIRE WALL EXISTING WALL NEW WALL `\./ ^ w � � 0 z o ¢ w Q J � � Q �I.w UZ�N>�'-1 Old Z W¢ V �1 U Z m 0 -1 W U W Q ¢ N �� Nw;QS�2zRo U Or rf LZ mFc?NR� M M O v m� V) Li Q:f U wd 1- W N = EL C-D �� zw�A Z: Z U Z C-) o 0 O CD cm 2-1 W 0 CZ9 =) Ln oo 0 ••uu•• n �/� •� •• Ld �''•!c<iLL P.•' •. :co o O U Q O. Z J 4b ......... . 0 •��� z J 0 cl- w Q W ' M M o � ll z o u A� h� 7 h�l O r� o cr- U cn W N W J N L a- REVISION 1 2 3 4 5 6 7 PROJECT TYPE: RENOVATION SCALE AS SHOWN ISSUED DATE: 03_08_2024 DRAWN BY: A.FENG CHECKED BY: A. LI AN G SHEET A 1 �t t t , iN S ; ti i E�4:UIPMENT PLAN SC:AL-E: 1 /4"= V-0" - t t t 15 4 11 lit ! 1, ? Ly ;I I; 13 D ME L_,_ ME OEQUIPMENT SCHEDULE EQUIPMENT SCHEDULE NO OTY. DESCRIPTION MANUFACTURE MODEL U.L.N S.F. ELECTRICAL GAS WATER WASTE VOLT PHS. HP. KW. SIZE BTUH C.W. H.W. DIR. INO. 1 3 HOOD ECON AIRE U.L. 2 1 HOOD ECON AIRE 3 2 RICE WARMER AVANTCO RCSB60 N.S.F. 120 1 4 3 DEEP FRYER PTICO SG-16 N.S.F. 3/4" 110,000 BTU 5 1 RICE COOKER RINNAI RER-55AS N.S.F. 1/2" 35.000 BTU 6 1 CHINESE STOVE WIN SUPPLY WR-700 N.S.F. 1" 700,000 BTU 1" 3" 7 1 GRIDDLE COOKING PERFORMANCE G60-NG N.S.F. 3/4" 150,000 BTU 8 1 CONVECTION OVEN COOKING PERFORMANCE FGC-200-NK N.S.F. 3/4" 108.000 BTU 9 2 WORKTOP COOLER AVANTCO SS-WT-72R-HC N.S.F. 115 1 1/3 0.59 10 2 SANDWICH UNIT AVANTCO C-SP72-16-HC N.S.F. 115 1 1/3 0.59 11 2 HOT HOLDING UNIT DELFIELD N8887 N.S.F. 208 1 12 2 COLD HOLDING UNIT DELFIELD N8081 N.S.F. 120 1 13 1 COLD HOLDING UNIT DELFIELD N8056 N.S.F. 120 1 14 1 ICE MAKER EXISTING N.S.F. 115 1 1.75 15 6 HAND SINK EAGLE/EXISTING HAS-10-F-LRS N.S.F. 1/2" 1/2" 2" 16 1 3—COMP. SINK REGENCY N.S.F. 3/4" 3/4" 3" 17 1 2—COMP. SINK REGENCY N.S.F. 3/4" 3/4" 3" 18 1 REACH —IN COOLER AVANTCO GDC-23—HC N.S.F. 19 1 MOP SINK SELECTED BY OWNER N.S.F. 1/2" 1/2" 2" 20 2 SODA DISP. PROVIDE BY COCA —COLA N.S.F. 21 1 WALK—IN COOLER AMERICAKOOLER 19'-0" X8'-0"' N.S.F. 208 1 1/3 1.52 22 1 WALK—IN FREEZER AMERICAKOOLER 10'-0" X 10'-0" N.S.F. 208 3 1/3 1 23 1 REACH —IN COOLER AVANTCO SS-3R—HC N.S.F. 115 1 1/3 0.59 24 1 COUNTER CUSTOM 25 WALL MOUNTED SHELVE(Stainless Steel) EAGLE PWE-14-3S N.S.F. 26 LOT TABLE(Stainless Steel) EAGLE T3036. T3072 N.S.F. 27 LOT SHELVE(Stainless Steel) EAGLE 1842S N.S.F. 28 POS CUSTOM 29 1 1 DISH WASHER JACKSON N.S.F. 208 1 10.1 3/4" 3/4" 3" 30 1 SOLID TABLE EAGLE N.S_F. 31 1 CLEAN TABLE EAGLE N.S.F. 32 1 ICE CREAM FREEZER MASTER BILT MSF-71AN N.S.F. 115 1 1/3 0.59 33 2 DIP WELL 34 1 WATER HEATER RINNAI EU199 N.S.F. 3/4"' 1 199,000 BTU 1 3/4" 1 3/4" FINISH SCHEDULE TOE BASE COVING FLOOR CEILING WALL DINING AREA CERAMIC TILE. CERAMIC TILE. 2X2 LAY -IN ACOUSTICAL CEILING, NON -PERFORATED, NON -FISSURED, GYPSUM FIRECODE PAINTED W/2-COATS SMOOTH, WASHABLE, LIGHT -IN COLOR. VINYL FINISH. OF EPDXY PAINT. 2X2 LAY -IN ACOUSTICAL CEILING AND DRYWALL CEILING, GYPSUM FIRECODE PAINTED W/2-COATS BUFFET AREA CERAMIC TILE. CERAMIC TILE. NON -PERFORATED, NON -FISSURED, SMOOTH, WASHABLE, LIGHT -IN COLOR. VINYL FINISH. OF EPDXY PAINT. EXISTING DRYWALL CEILING, NON -PERFORATED, NON -FISSURED, CERAMIC TILE FINISHED 4 FEET A.F.F. TOILET ROOM CERAMIC TILE. CERAMIC TILE. SMOOTH, WASHABLE, LIGHT -IN COLOR. VINYL FINISH. ,GYPSUM FIRECODE PAINTED W/2-COATS OF EPDXY PAINT. KITCHEN AREA QUARRY TILE. QUARRY TILE. EXISTING DRYWALL CEILING, NON -PERFORATED, NON -FISSURED, STAINLESS STEEL BEHIND HOOD AREA SMOOTH, WASHABLE, LIGHT -IN COLOR. VINYL FINISH. AND FRP PANELING IN OTHER AREA. FINISH NOTES: 1. ALL FINISHED SURFACES SHALL BE SMOOTH, EASILY CLEANABLE AND NON ABSORBENT. 2. ALL DAMAGE CREATED OR DISCOVERED IN THE PROCESS OF THE CONSTRUCTION PHASE OF THE PROJECT SHALL BE PROPERLY REFINISHED IN AN APPROVABLE MANNER. ALL SURFACE PENETRATIONS, CRACKS AND CREVICES ARE TO BE SEALED TO ELIMINATE VERMIN HARBORAGE AREAS. 3. ALL PLUMBING PIPES, ELECTRICAL CONDUITS, GAS LINES, ETC. SHALL BE KEPT WITHIN THE WALL CAVITIES, ABOVE THE CEILING OR UNDER THE FLOOR. IF THE GAS LINE MUST BE RUN OUTSIDE OF THE WALLS, THEN A CLEANABBE BRACKET MUST BE USED THAT WILL BRACE THE PIPE AT LEAST 1 " OF THE WALL AND AT LEAST AT 12" OFF THE FLOOR. 4. UTILITY LINES SHOULD BE STUBBED OUT OF THE WALLS, FLOORS OR CEILINGS AT EACH PIECE OF EQUIPMENT SERVED, U Lu Lu �- 1 l 1 Q JpF-Q Wes' Z (2)M W N> N W W CD w ¢ = � m o U Z U JwoQI-'-) J<�V)o=U ►--I �i �(V L`'raNz�o m W S2 (n W O rV►1 M M (\ W m V) LA_ � U m LLJ '--I C) c:1 = J LLJ 1- 00 d r- M C/) QQV)=Qw Q wwwzj— wo_vEjaLoz � 000NNQA QoUz� Jo oz W O O - CZ7 O 0 �%'••. w .•••••� 4b N, • V 4u 0) LL �' i f� � J • :� � CD •� o �•Lu 0: it lks l lot c� 0 cl- w r— ¢ 0 w ^ � z AM Zz U H � W WWI a Aix Wei �--•1 ^ � � `_ _ O W �- ce �60w w a L`7c�N 0 REVISION 1 2 3 4 5 6 7 I PROJECT TYPE: RENOVATION SCALE AS SHOWN ISSUED DATE: 03_08_2024 DRAWN BY: A. FEN G CHECKED BY: A. LI AN G SHEET I LI F _ SAFETY PLAN KAI: 1 /4"=1'-0" LIFE SAFETY LEGEND MAXIMUM TRAVEL DISTANCE DIRECTION OF EGRESS FE1 FIRE EXTINGUISHER (FE) a FE1 SHALL HAVE MINIMUM RATING OF 3A-40BC FE1 TYPE ABC PROVIDE 10# MULTI -PURPOSE FIRE a EXTINGUISHER MOUNTED WITH WALL HOOKS AT 48" AFF AND CERTIFIED FE-K TYPE K PRIOR TO INSTALLATION. TRAVEL DISTANCE BETWEEN FE NOT TO EXCEED 75 FT ® EXIT SIGN ®1 DIRECTIONAL EXIT SIGN EMERGENCY LIGHTS STATEMENT: OUR DESIGN TO THE BEST OF OUR KNOWLEDGE COMPLIES WITH THE 8TH ED FFPC. u , p ¢ o�QW�W z W a Ef w¢=pMo UJWOQ~.0 ►--� dam' N W���o=z � o ►z 0°�_�c�-nw� r0� O v M M M p N p p w l�M� LLLLj ¢Wt—ww zooz0¢ 00 Q Q L) J O r/l-4 /� �p��.11 N LLJ p C.DZ W � ¢ (� 0 O c_Z9=a_ Z Q A� ar�00 N CD 0 , ; Q •LL .Z . J. W :CD .� o z Q o• Z. F . cn �c,: Ln Q a_ Q W Q 0 J L'i d 1� M � M ►-� z gz CD A Z A � a LL < A� ,-� a w F U � F- LL W � W U m N J REVISION 1 1 2 3 1 4 _I 5 6 1 7 I PROJECT TYPE: RENOVATION SCALE AS SHOWN ISSUED DATE: 03_08_2024 DRAWN BY: A. FEN G CHECKED BY: A,LIANG SHEET IREFLECTED CEILING PLAN SYMBOL SCHEDULE MAY NOT USE ALL THE SYMBOLS 2x4 SURFACE MOUNTED TROFFER FLUORESCENT LIGHT FIXTURE rz-1 2x2 SURFACE MOUNTED TROFFER FLUORESCENT LIGHT FIXTURE SUPPLY DIFFUSER ®RETURN DIFFUSER REFLECTIVE CEILING NOTES: 1. CEILING HEIGHT IS SET AT 10'-0" EXISITNG ROOF SYSTEM 40 -DETAIL "A2" 12GA GALVANIZED WIRE 0 48" O.C. 2X2 LAY -IN ACOUSTICAL CEILING `� 1/2" GYPSUM BOARD 3/8"0 ZINC THREADED ROD 0 60" O.C. 3 5/8" METAL STUDS 0 60" O.C. i i 3 5/8" METAL STUDS" 0 16" O.C. `1/2" GYPSUM BOARD DETAIL -Al EXISTING ROOF SYSTEM 40 I D "A2" 3/8"0 ZINC THREADED ROD 12GA GALVANIZED WIRE 060" O.C. ® 48" O.C. 3 5/8" METAL STUDS 3 5/8" METAL STUDS 0 16" O.C. 0 60" O.C. °D 3 5/8" METAL STUDS 0 16" O.C. Lo 1/2" GYPSUM BOARD - � R" � 2X2 LAY -IN ACOUSTICAL 3 5/8" METAL STUDS 0 16" O.C. �IUUNU 1/2" GYPSUM BOARD SOFFIT DETAIL SCALEAT.S. DETAIL "Al* NUT O CEILING MOUNTED LIGHT FIXTURE ® CEILING MOUNTED 6" DOWN LIGHT FIXTURE TRACK LIGHT FIXTURE EXHUAST DIFFUSER DETAIL -Al DETAIL—A2 NC THREADED I" O.C. ZINC THREADED i60" O.C. FENDER WASHER ^ w p o ¢W Zoe ¢ <c1t Lq UUmwLnn>W 1 yy "o � W ¢=pLo U Z m0 U rl V U J m O Q _j C=) = U LJ O W� Q N W mC7�tn W Ov m M to m LLAp N L. p p w � t/ 7 Q Q( N m cQ W Wi>�wwZ� zw A r� O � poC-) N QQ V JO W O c C=�z¢ oo `" °' 0 .• Ln * �3 •. w • ' :�c9 •. CD •v:� rn ••2: � 6:�• :� v •. :(D:w O �: J �c H Q: z . V • O W Z. -j cn 4c; �. ; Q J •� , )• •. b'••••...... ,!�•j(7� .• `` •• z J Q O Q W Q 0 _J W z a z M � ►=-1 Z Of � z o M V1 w Z� W w W A i x w O�W a F=! Ww a � REVISION 1 1 2 1 3 1 4 1 5 1 s 1 7 I PROJECT TYPE: RENOVATION SCALE AS SHOWN ISSUED DATE: 03-08-2024 DRAWN BY: A.FENG CHECKED BY: A. LI AN G SHEET A3 -_ �11iil:�iv1■�i _� -- e - BUFFET TABLE SNEEZE GUARDS REQUIREMENTS: (PER NSF STANDARD #2) — ALL BUFFET TABLES MUST BE COVERED TOPS, SIDES & FRONTS. — MINIMUM COVERAGE FRONT/SIDES 18" @ 30-45 DEGREE SLANTED GLASS — CAN NOT EXCEED 13" ABOVE COUNTER SLANT — BOTTOM LEADING EDGE OF THE FOOD SHIELD SHALL EXTEND A MINIMUM HORIZONTAL DISTANCE OF 7" BEYOND THE FRONT INSIDE EDGE OF A FOOD WELL TEMPERED GLASS & TEMPE STAINLESS STEEL GLASS SNEEZE GUARD Stainless Steel Channels TEMPERED GLASS TEMPERED GLASS & STAINLESS STEEL SNEEZE GUARD ,g 3/4" GRANITE m m 3/4" GRANITE ,g 'I COUNTER TOP COUNTER TOP s,M `f STAINLESS STEEL STAINLESS STEEL FOOD PA = FOOD PAN d — OVER 3/4" PLYWOOD = OVER 3/4" PLYWOOD — ' m C� STAINLESS �� 3/4 PLY. WOOD `'� " 3/4 PLY. WOOD STAINLESS STEEL cn STEEL 2"X3" WOOD STUD N N 2"XY WOOD STUD OVER 3/4 N N OVER 3/ 2"X4" WOOD STUD 2"X4" WOOD STUD- PLYWOOD PLYWOOD 024 O.C. 024 O.C. i STAINLESS STEEL LEG �0 STAINLESS STEEL LEG E UFFET TABLE DETAIL ::.ALE:N.T.S. DOOR SCHEDULE NO. MARK SIZE MATERIAL FRAME FINISH RATING REMARKS 1 STORE FRONT 3'-0" x 7'-0" x 1 3/4" EXISTING ALUMINUM& TEMPERED GALSS ALUM BRONZE — PANIC HARDWARE IS REQUIRED 2 STORE BACK, SIDE 3'-0" x 7'-0" x 1 3/4" EXISTING HOLLOW METAL METAL PAINT — PANIC HARDWARE IS REQUIRED STORAGE, RESTROOM, ADA COMPLIANT "MEN" 3 KITCHEN, 3'-0" x 6'-8" x 1 3/4" EXISTING HOLLOW CORE WOOD WOOD PAINT — &"WOMAN"SIGN MOUNTING MECHANICAL ROOM HEIGHT@ 48" AFF DOOR NOTES: 1. LATCH SIDE CLEARANCES AT ALL DOORWAYS SHALL BE IN ACCORDANCE WITH FBCA, SECTION 404.2.4 2. ALL EXITS TO BE LABELED. 3. INTERIOR DOORS TO BE LABELED AS TO INTENDED USE. 4. ALL EXIT DOORS SHALL BE PROVIDED WITH PANIC HARDWARE, EXCEPT FRONT DOOR, SEE REMARKS. 5. THE OPERATING DEVICE ON ALL DOORS SHALL BE CAPABLE OF OPERATION WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, TIGHT PINCHING OR TWISTING OF THE WRIST TO OPERATE. THE INTERIOR HINGED DOOR SHALL BE 5.0 POUNDS (22.2 N) MAXIMUM PER FBCA SECTION 404.2.9 6. ALL INTERIOR DOORS TO BE LEVER TYPE WITH DOOR CLOSERS AND 1 /2" THRESHOLD. 7. LANDINGS SHALL BE PROVIDED AT EVERY REQUIRED EXIT IF ABOVE OR BELOW GRADE AND THEY SHALL BE A MINIMUM OF 36 INCHES IN WIDTH AND 44 INCHES LONG IN THE DIRECTION OF TRAVEL PER FBCB SECTION 101.1.6 LOCKSETS WEATHERSTRIP(W) NO. TYPE MODEL FINISH BRAND 1 THRESHOLD 171A-36" AL PEMCO 2 THRESHOLD 171A-36" AL PEMCO 3 WEATHERSTRIP SET 303—AV AL PEMCO 4 DRIP CAP 346C-36" AL PEMCO 5 DOOR BOTTOM 216AV-36" AL PEMCO PANIC(C) NO. TYPE MODEL FINISH BRAND 1 SURF. MNT RODDED PANIC MANUF. STNDRD US32D KAWNEER 2 PANIC —RIM DEVICE 98/98 RIM US32D VON DUPRIN PUSH/PULL(P) NO. DIRECTION TYPE MODEL FINISH BRAND 1 LEAF PULL 98OP US32D HAGER 2 LEAF PUSH 1105 US32D HAGER 3 LEAF PULL MANUFACTURER'S STANDARD NOTE: 1. ALL INTERIOR DOOR HARDWARE TO BE SCHLAGE TYPE "AL -SERIES." REF. BUYER SPECIFICATIONS FOR FINISHES. 2. KEY ALL LOCKS TO MATCH ENTRANCE DOOR LOCKS. 3. IF NO EXISTING PANIC HARDWARE ON EXISTING EXTERIOR DOORS, USE C-1 FOR DOUBLE LEAF OPENINGS AND C-2 FOR SINGLE. VINYL FACE PULL SIDE PULL SIDE 24 I 20 GAUGE METAL STUD FACOUSTICAL CEILING ECD x co 14 pre erred ~ x ,� c @ 4- O = - r__ �'�IF 5TAINLE55 STEEL FINI5h1 5/8" GYPSUM WALL BOARS 3" AIR 5PACE 3 5/8" METAL STUE SELF -SERVE @ I E" O.C. 1 STAINLESS STEEL SNEEZE GRANITE FINISH TAR-, - CERAMIC TILE /8" GYPSUM WALL BOA$I — 3 5/8" METAL STUDS i11 @ I G" O.C. STAINLESS STEEL fIN15 E G" COVE BASE IUD' 3/8" DIATHREADED I ANCHO D TO TOP EXISTING STEEL BAR HOOD c� l T GRIDDLE N FIN OPEN KITCH E FINISHED WALL 5TAINLE55 STEEL LEG ,)ECTON THRU. OPEN KITCHEN AREA SCALE:N.T.S. EXISTING ROOF TRUST 3 5/8" STEEL STUDS 3 5/8" STEEL STUDS CEILING 10 -0 A.F.F. BUILDING STANDARD CEILING PANEL & GRID �4 FASTEN STUD RUNNER TO CEILING GRID @ 48' O.C. (MAX.) 3 548" STEEL STUDS 4 . @ 4" O.C. WITH RUNNER @ TOP & BOTTOM @ 22 GA. 1/2" GYPSUM BOARD EACH SIDE 4 BASE (SEE FINISH'SCHEDULE) GALV. STEEL FLOOR TRACK ATTACHED �jN�SH SCF{EDULE) W/FASTENERS 0 24" MAXIMUM SPACING t;;�WALL DETAILS SCALE:N.T.S. *93VI A TOP OF WALL 4*-6' A.F.F. L� CORNER BEAD, TAPED AND SPACKLED 3 548" STEEL STUDS @ 4° O.C. WITH RUNNER @ TOP & BOTTOM @22 GA. 2" GYPSUM E D EACH S(SCH HEDULE) SOHI SC9 LE) <� W2 WALL DETAILS, > SCALE:N.T.S. NEW 4" THICK CONCRETE SLAB MINIMUM OF 3000PSI 6 MILL VAPOR BARRIER ON 4" MIN. TERMITE TREATED COMPACTED FILL X p X .X p ' RE `� #3 REBAR�36"O.C. 2" EMBED WITH EPDXY 6 MIL POLYTHL VAPOR BARRIER PER FBC 1901.1 COMPACTED FILL 12" LIFTS TESTED TO 95% COMPACTION CAP BETWEEN 18" TO 30" CONCRETE SLAB ON GRADE SCALE:N.T.S. NOTE: x = 36 IN MINIMUM IF y = 60 IN NOTE: y = 54 IN MINIMUM IF THE DOOR (A) FRONT APPROACHES x = 42 IN MINIMUM IF y = 54 IN. HAS A CLOSER. (B) HINGE SIDE APPROACHES (C) LATCH SIDE APPROACHES x 54 min. PUSH SIDE �, PUSH SIDE PUSH SIDE 'E NOTE: x = 12 I IF THE OOR NOTE: y = IN IF DOOR HAS NOTE: y = 48 IN IN. IF E DOOR HAS A HAS BOTH A CLO R AN A LATCH. BOTH A LAT AN A CLOSER. CLOSER. PROVISIONS FOR BARRIER FREE DOORS) SCALE: NTS �� o ¢ M Z�►—¢[r V l ¢ C.7 W N > vi W 1.4 O ccU LAj Z m CO ON O [� Jul W=cam rV �N Q o w �¢Nz�C� w m��Nw ch U = N � !: CZUJ z wz (j 0 o zooz�Q �¢¢ooJC) oM ¢ =zzzoo conpob oo CL 0 Lj . z _. cD LLI :(D:W 0:: w :v o .y ;> Z i �� C) C0 4(•; �� Q G, • �'• fib►''••••......• �� �.. ire z c� Q 0 cl- 0- a w 0 J W Cr W N —j M Q z � M 0 of J Z 1Z a � ~ Z ►-- w W w C) WLLJ o LIMN <C REVISION 1 I 2 3 4 5 6 7 PROJECT TYPE: RENOVATION SCALE AS SHOWN ISSUED DATE: 03-08_2024 DRAWN BY; A.FENG CHECKED BY: A.LIANG SHEET A4 GRANITE COUNTER TOP OR 3/4 PLYWOOD W/ FORMICA FINISHED f _ FINISHED FLOOR - -EQ SERVICE COUNTER TOTAL LENGTH: 18'-9" ADA HEIGHT: 2'-10" TOTAL HEIGHT: 3'-6" TOTAL WIDTH: 4'-0" MATERIAL: 1 " THICK PLYWOOD W/ FRP COATING MIN. 36" S"°i 30LS OF ACCESSIBILITY AND THEIR BACKGROUND SHALL HAVE A N0 I -GLARE FINISH. SYMBOLS OF ACCESSIBILITY SHALL CONTRAST V� I - THEIR BACKGROUNDS, WITH EITHER A LIGHT SYMBOL ON A D� 1C BACKGROUND OR A DARK SYMBOL ON A LIGHT Bt'., KGROUND. WOMEN z MEN - - NOT IN 0 PICTOGRAM • •• AREA H: JNTING HEIGHT: CHARACTERS SHALL BE 48 INCHES MINIMUM /0 ; 60 INCHES MAXIMUM ABOVE THE ADJACENT FLOOR OR (, � .',UND SURFACE, MEASURED FROM THE BASELINE OF THE f ; -,A RACTERS. NI: JNTING LOCATION: WHERE A TACTILE SIGN IS PROVIDED AT A 'jR, THE SIGN SHALL BE ALONGSIDE THE DOOR ON THE LATCH (A) ELEVATION 8" MIN. 00 N, — 9" ' 230 6" MAX. 150 FIG. 306.2 TOE CLEARANCE 9" MIN. 230 11" MIN. 280 (A) ELEVATION NOTE: EACH DOOR TO AN EXIT SHALL HAVE A TACTILE SIGN, MOUNTING HEIGHT 48" MIN. AND 60" MAX. ABOVE ADJACENT FLOOR OR GROUND SURFACE. INCLUDING RAISED LETTERS AND BRAILLE, STATING: EXIT BRAILLE SHALL BE MOUNTED 48" MIN. -60" MAX. AFF. TO THE BASELINE OF THE BRAILLE. PER ANSI -Al 17.1-2012 SECTION 703.4.5 9" ON CENTER / FROM DOOR FRAME ICC/ANSI SECTION 703.3.10 & SECTION 703.4.5 O � m a z � 0 00 co 430 - 635 (B) PLAN 25" MAX. 635 (B) PLAN FIG. 306.3 KNEE CLEARANCE CEILING 8'-0" A.F.F. EXIT 4'-0" A.F.F. gas 1'-6" A.F.F. � pZH FEU- pE I 1 I / Q4 KNEE & TOE' CLEARANCE ✓_ I M 30"X48" CLEAR FLOOR SPACE, SERVICE COUNTER/BAR FRONLAPPROACH NOTE: HANDICAP ACCESSIBLE SEATING 5% OF TOTAL SEATING CAPACITY TOTAL SEATING 160 X 5% =8 EXIT SIGN 8 HANDICAP ACC. SEATS PROVIDED SWITCHES -RECEPTACLES FLOOR DEVICE MOUNTING HEIGHTS DETAIL N.T.S. co 1 TABLE HEIGHT: 28"-34" / - - 48" / X\ Io 30" / -- 36" MIN. CLEARANCE FOR SEATING AND TABLES FAC 308.2.1 UNOBSTRUCTED FORWARD REACH M f►L1,1,L��I (A) 255 255 (A) FAC 308.3.1 FAC 308.3.2 UNOBSTRUCTED SIDE REACH OBSTRUCTED HIGH SIDE REACH FAC 309.3 OPERABLE PARTS SHALL BE PLANED WITHIN ONE OR MORE OF REACH RANGES SPECIFIED IN 308 D N :V r FAC 308.2.2 (B) OBSTRUCTED HIGH FORWARD REACH O N_ u r— W C� pj � Z Q l� ` Q J = Q W p W V) > W O� w Q U Z LLJ m 0 ^ U J w O Q U UO�o WV)opZ W QDLLJ LLJm N p p� w LAJ J U LLJ = ���ozr V) Q W O Q �ocMc) C) < <c C) w o 2- F- o ° o N CL Q� aa�Ioo CL U- o O J: (� : w H : - 0 Q O: Z ' 6 Z -,: p . cn 4, ��. folosssss z Q Q L Q I N � Q M Q Q w r ui W �V W (. c LLLJCD Q REVISION 1 2 3 a I 5 6 7 I PROJECT TYPE: RENOVATION SCALE AS SHOWN ISSUED DATE: 03_08_2024 DRAWN BY: A.EENG CHECKED BY: A. LI AN G SHEET A5 EXISTING EXHAUST DUCT THROUGH THE WALL TO RESTROOM, IN 80 METAL DUCT(TYP.) 7T I EX. I� 8"0 �� I i I I ( o � II lii EX. M ~! 06M 606"0 NM 1050 EXISTING 8X6 EXISTING 12X10 EXISTING 1OX10 I g 00 ,FM 60 EXISTING 14X14 EXISTING 1OX8 x N Z EXISTING RETURN AIR EXCHANGE GRIDDLE(TYP.) 00 rrrm EXISTING AHU#1-4 �� EXiSS T ING EXISTING 18X16 5 TON ! WALK-IN 2000 COOLER CFM(EACH) r Z I-= I c in W c0 X X � O Z O N z F W EXISTING 16X14 400 f'4CFM10000 XISTING 20"X18" UA DUCT HROUGH ROOF O EXISTING MUA-1 400 cFM 000 4"X12" 400 400 400 GREASE DUCT CFM CFM CFM THROUGH ROOF 100 100 100 TO KEF-4 I � EXISTING 12X10 H_'�r K PLAN SC:_E: 1 /4' =1,-0" EXISTING 16X14 150 I 1 L.'---J MUA DUCT THROUGH ROOF TO MUA-2 12"0 EXHAUST DUCT THROUGH ROOF TO DEF-1 _O 16"X16" X GREASE DUCT 04 THROUGH ROOF TO KEF-1 O Z N w 6"X16" GREASE DUCT THROUGH ROOF TO KEF-2 6"X 16" GREASE DUCT THROUGH ROOF TO KEF-3 DESIGN NOTES: DESIGN AND INSTALLATION TO W/FBC 2023 8TH EDITION -WIND LOADING:140 MPH, -RISK CATEGORY: II -IMPORTANCE FACTOR: 1=1.0 -EXPOSURE: "B" -WIND LOADING: ROOF LIVE LOAD: 20 PSF r REPLACED w.aLX-Iry FREEZER 10' _ 0 "X I il' - 0' VENTILATION CALCULATIONS (BASED ON FBCM 8TH EDITION TABLE 403.3.1 .1 ) OCCUPANCY CATEGORY SQ FT SF/P P CFM/P CFM/SF CFM (P) CFM (AREA) TOTAL CFM NOTES DINING AREA 1997 160 7.5 0.18 1200 359 1559 KITCHEN&SERVICE AREA 1451 100 145 7.5 0.18 1088 261 1349 BUSINESS 1007 50 50 5 0.06 252 60 312 KITCHEN (COOKING) 140 20 3 -7.5 -0.12 -21 -17 -38 TOILET ROOMS(PUBLIC) 319 5 -50 0 -250 0 -250 TOTAL CFM REQUIRED: 2933 AC UNIT OUTSIDE AIR CFM PROVIDED 2000 MUA CFM PROVIDED 8400 TOTAL CFM PROVIDED 10400 NOTES: FOR ALL CATEGORIES: OCCUPANCY CATEGORY AND DENSITY FROM TABLE 403.3.1.1 FBCM 8TH ENTILATION GENERAL NOTES: 1. VENTILATORS & DUCT SHALL BE DESIGNED, CONSTRUCTED AND INSTALLED IN ACCORDANCE WITH SECTION 506.3.1 THROUGH 506.3.12 OF (2023 FBC-MECHANICAL 8TH EDITION), (NFPA 96 2017 EDITION CHAPTER 6 THROUGH CHAPTER 8) 2. EXHAUST HOOD SHA LL BE DESIGNED, CONSTRUCTED AND INSTALLED IN ACCORDANCE WITH 2O23 FBC-MECHANICAL, 8TH EDITION SECTION 507.2.5 THROUGH 507.2.9. AND NFPA 96 2017 EDITION CHAPTER 5. 3. TYPE I HOODS SHALL CONSTRUCTED OF STEEL NOT LESS THAN 0.043 INCH (1.09MM) (NO. 18 MSG) IN THICKNESS, OR STAINLESS STEEL NOT LESS THAN 0.037 INCH (0.94MM) (NO. 20 MSG) IN THICKNESS (5.1.1 NFPA 96 2017 EDITION). 4. EXHAUST FAN HOUSINGS SERVING A TYPE I HOODS SHALL BE CONSTRUCTED OF STEEL (2023 FBC-MECHANICAL SECTION 506.5) AND (8.1.4 NFPA 96 2017). EXHAUST FAN MOTORS SHALL BE LOCATED OUTSIDE OF THE EXHAUST AIRSTREAM (2023 FBC-MECHANICAL SECTION 506.5.1.1) AND (7.8.1 NFPA 96 2017 EDITION). 5. - GREASE DUCTS SERVING TYPE I HOODS SHALL BE CONSTRUCTED OF STEEL HAVING A MINIMUM THICKNESS OF 0.0575 INCH (1.463 MM) (NO. 16 GAGE) OR STAINLESS STEEL NOT LESS THAN 0.0450 INCH (1.14 MM) (NO. 18 GAGE) IN THICKNESS. (2023 FBC-MECHANICAL SECTION 506.3.1.1) AND (7.5.1 NFPA 96 2017 EDITION) - ALL SEAMS, JOINTS, AND PENETRATION OF GREASE DUCTS SHALL BE MADE WITH A CONTINUOUS LIQUID -TIGHT WELD OR BRAZE MADE ON THE EXTERNAL SURFACE OF THE DUCT SYSTEM (PER 2023 FBC-MECHANICAL, SECTION 506.3.2) AND (7.5.2.1 NFPA 96 2017 EDITION) - DUCT JOINTS SHALL BE BUTT JOINTS OR OVERLAPPING DUCT JOINTS OF EITHER THE TELESCOPING OR BELL TYPE. (PER 2023 FBC-MECHANICAL SECTION 506.3.2.1.) AND (7.5.5 NFPA 96 2017 EDITION) - DUCT -TO -HOOD JOINTS PER (2023 FBC-MECHANICAL SECTION 506.3.2.2) AND (7.5.2.2 NFPA 96 2017 EDITION). - DUCT -TO -EXHAUST FAN CONNECTIONS PER (2023 FBC-MECHANICAL SECTION 506.3.2.3) AND (7.5.1 NFPA 96 2017 EDITION) - VIBRATION ISOLATION CONNECTOR FOR CONNECTING A DUCT TO A FAN SHALL BE (2023 FBC-MECHANICAL SECTION 506.3.2.4.) - GREASE DUCT SUPPORTS (2023 FBC-MECHANICAL SECTION 506.3.3) 6. GREASE DUCT SYSTEMS SERVING A TYPE I HOOD SHALL HAVE A CLEARANCE TO COMBUSTIBLE CONSTRUCTION OF NOT LESS THAN 18 INCHES (457 MM) (2023 FBC-MECHANICAL SECTION 506.3.6) AND (SECTION 13-4.1 OF NFPA1 , THE FIRE CODE 2023 EDITION) 7. THE FIRE EXTINGUISHER SYSTEM MUST BE INSTALLED BY A LOCAL LICENSED COMPANY, SEPARATE PLAN MUST BE SUBMITTED TO LOCAL FIRE DEPT. FOR APPROVAL. (SECTION 13-2.1 THROUGH 13-3.9 OF NFPA1 , THE 2023 FIRE CODE) AND (SECTION 10.1 THROUGH 10.2.6 OF NFPA 96 2017 EDITION) 8. ALL ELECTRICAL WORK MUST BE DONE BY LOCAL LICENSED ELECTRICIAN. KEY NOTE: 1. GREASE HOOD FIRE SUPPRESSION CONTRACTOR SHALL SUBMIT SHOP DRAWING FOR APPROVAL AND PERMIT. 2. EXHAUST DUCT SHALL BE 18" AWAY FROM ANY COMBUSTIBLE MATERIAL 3. ACTIVATION OF FIRE SUPPRESSION SYSTEM SHUTS OFF ALL FUEL SOURCES, GAS AND ELECTRICITY UNDER THE HOOD INCLUDING SUPPLY AIR, LEAVES EXHAUST FAN RUNNING. 4. AN AUTOMATIC SUPPRESSION SYSTEM PROVIDING MANUAL ACTIVATION SHALL BE INSTALLED IN THE KITCHEN HOOD SYSTEM. 5. CONTRACTOR TO BALANCE THE AIR PER FBC 2023, SEC 601.4. PRESSURE DIFF. ACROSS CLOSED DOORS WHERE RETURNS ARE CENTRALLY LOCATED SHALL BE LIMITED TO 0.01 INCH WC OR LESS. 6. CONTRACTOR SHALL PROVIDED TEST AND BALANCE REPORT BEFORE FINAL MECHANICAL INSPECTION PER FECC 2023 SEC C408.2.2 NEW EXHAUST FAN & MAKE UP AIR UNITS SCHEDULE ELECTRICAL DATA SERVICE MFR. & MODEL EXT. NOTES (SEE ID LOCATION # TYPE CFM S.P. BELOW) W VOLTS PHASE KEF-1,2,3 KITCHEN ECON AIRE OR EQUAL ROOF 2700 1 - 208 1 1,2,3,4,5 KEF-4 KITCHEN ECON AIRE OR EQUAL ROOF 1800 1 - 208 1 1,2,3,4,5 FAN 1. NOTES: ALL FANS TO BE PROVIDED AND INSTALLED BY MECHANICAL CONTRACTOR. 2. PROVIDE FAN WITH CEILING TO INLINE CONVERSION KIT. 3. PROVIDE BACK -DRAFT DAMPER. 4. PROVIDE WEATHERHOOD 5. FAN SHALL OPERATE WITH LIGHT. AIR BALANCE SUMMARY ID LOCATION SUPPLY RETURN OUTSIDE I MAKE UP EXHAUST PRESSURE EX. AHU-1 2000 1500 500 EX. AHU-2 2000 1500 500 EX. AHU-3 2000 1500 500 500 EX. AHU-4 2000 1500 500 NEW KEF-4 -1500 KEF-1 -2700 KEF-2 -2700 DEF-1 -500 MUA-1 4000 -200 KEF-3 -2700 MUA-2 4400 EX. TEF-1 RESTROOM -250 -250 2000 8400 -10350 50 ^ w Z ~ w U ¢ Q I c ¢ Q C:f w "zc�owtw�cri w l w¢vzmo U w w-Qp L'7 O o w m��Nw� mLAJ �w J J � Fes- J Cr lr M (n "I--< == z w N �- w LLJJ Q U i Z r 000V) o c� Q °° � ���zz N 00 0) 0 • o O J c� n: Q z :v 2' Z O: Z- w Q JI - toF 'S: 10 • Q 0 Q w Q i I � M z � �I z o i Z WWI., a U W po w w> cL LIMN N= REVISION 1 1 2 3 1 4 5 6 1 PROJECT TYPE: RENOVATION SCALE AS SHOWN ISSUED DATE: 03-08-2024 DRAWN BY: A. FEN G CHECKED BY: A. LI AN G SHEET EXISTING TEF-1 SCALE: N.T.S. REPLACED - -- -` REPLACED DEF-1 KEF-1 NEW 0 KEF-4 REPLACED \ J / KEF-2 NEW KEF-3 1 _i-,_i_T I I_I - j l 7. NEW RI'' DE TOP EQUIPMENT PLAN S(:) _E: 1/4"=1'-0» MIN. 1 20" NEW NEW MUA-2 KEF 3 _ DISCHARGE OF FAN(TYP.) L. MIN. 120" REPLACED REPLACED KEF#2 KEF#1 NEW V 16X16 20"X20" 16X16 GREASE DUCT MUA DUCT CESS PANELS AT GREASE DUCT ALL CHANGE OF W/ FIRE WRAP / FIRE WRAP DIRECTION(TYP) CON ORM TO NFPA 96 A/P A/P � � a 14"0 b!U DUCT CN N MIN. " 00 Z M mm COOKER 0 Do FRONT Li'-6" 1;5I I`51 REPLACED MUA-1_ 4 EXISTING 20"X18" MUA DUCT 16X16 A/P GREASE DUCT W/ FIRE WRAP a Q 9'-01, 9'-0" `""OVEN M N.6" 7-CHME WOK DEEP DEEP DEEP FRYER FRYER FRYER BACK SLASH - -- WOK STOVE 15'-1" 1 jl'-4"jjl'-4"jj1'-4"jI 3'-2" KEF#4 DISCHARGE OF FAN z .0 Existing ACCESS PANELS AT ALL CHANGE OF DIRECTION(TYP) CONFORM TO NFPA 96 A/P 12"X12" GREASE DUC W/FIRE WRAP �r CEILING HOOD 6'-0" M16" M16" GRIDDLE FRONT 5'-0" HOOD SYSTEM ELEVATION SCALE: N.T.S. CEILING FLOOR KEF#4 DISCHARGE OF FAN z G*7 12"X12" - GREASE DUCT W/ FIRE WRAP Q CEILING tj N 3" AIR SPACE Gas Griddle & Sneeze Guard Char —Broiler Granite (non—charcaol( )S /5/8" Cement Board / -5/8" GYP. BD. 0 o Stainless 3/8" Ceramic Tile Floor 09 = Steel Tabl ` 3 5/8 metal studs SIDE INSULATED FLEXIBLE DUCT, INSTALL FLEX —DUCT AS STRAIGHT AS POSSIBLE. NO BEND OVER 90% NO CRUSHING OF FLEX —DUCT. 1" HANGER STRAPS i MAX. 10' SPACING SUPPLY DUCT \ I MANUAL VOLUME DAMPER I METAL COLLAR WITH BAND CLAMP, SCREWED (3) PLACES AND TAPE TYPICAL BOTH ENDS OF FLEX DUCT. MINIMUM RADIUS EQUAL i TO DUCT DIAMETER OR PROVIDE AN AIR j STRAIGHTENING GRID. INSULATION BOOT. L-- DIFFUSER SEE PLANS FOR TYPE DIFFUSER TAKEOFF DETAIL SCALE: N.T.S. ^ w o r ZLLJ� p W Q ` JpF—Q� CDMwCW>w U� w Q v Z m wp U U J �w U Q U F—I 1 O O O w m (_5_ ~ U5 w Ur M M n w � w m o cCD J J � J 00 [� en of w ww _ Z zw Q 000�NQ W Z U Z F- ¢¢M��CD 0000 w = F__ C_�ofZQ 00 w 6; 0 co qt O�:Q: :(D:w �c O z :U O: z. w z > Z F- -/; C) � U) k•C7�: Q 'S •• Q . F� LLJ z Q i I 0 Q CL QZ J N �— d' F- 0 Q M W a z O � Q ^ N C Uj w O O1 W LU U cn N N oC REVISION 1 1 2 3 4 5 6 7 PROJECT TYPE: RENOVATION SCALE AS SHOWN ISSUED DATE: 03_08_2024 DRAWN BY: A.FENG CHECKED BY: A. LI AN G SHEET M2 Op A►�GOORED 1O �o op IRON pIA TAR AN HOOD ISOMETRIC VIEW SCALEXT.S. 0 EXISTING ROOF SYSTEM G ANGLE S EA OGIOP j� G A00 OAGH #1GI HOOD SP S1 fE�pED PNLI, O DETAIL 3/8" DIA. ALL THREAD ROD CONNECTED TO ROOF JOIST THROUGH ANOTHER HANGING ANGLE 1.5" X 1.5" "U" CHANNEL NUT FENDER WASHER 3/8" DIA THREADED ROD TO KINDORF CHANNEL STEEL HANGING ANGLE EAVY DUTY NUT AND DNE ABOVE AND ONE ;ING ANGLE ROD, NUTS, AND WASHERS TO BE SUPPLIED BY INSTALLING CONTRACTOR HANGING ANGLE IS PRE -PUNCHED AT FACTORY (: ) B PSP HANGING ANGLE 3/8" DIA. ALL THREAD ROD CONNECTED TO ROOF JOIST THROUGH ANOTHER 1 5" X 1.5" U CHANEL HANGING ANGLE STEEL HANGING ANGLE TO TOP CORD OF ROOF JOISTS / _:(IST'G SUSPENE /8" DIA THREADED ROD ^ILING SYSTEM CLAM TO TO TOP CHORD OF EXISTING ROOF JOIST TYP. 3/8" DIA. HEAVY DUTY NUT ;stainless steel sheet.9 raj AND WASHER - ONE ABOVE n 5/8" gyp. wall board _ 16 GA STAINLESS STEEL AND ONE BELOW HANGING ANGLE from floor to Ceiling B Hoon CHANNEL CLIP FULL Lj WELDED TO HOOD TYP. ROD, NUTS, AND WASHERS TO BE SUPPLIED BY INSTALLING CONTRACTOR HANGING ANGLE IS PRE -PUNCHED AT FACTORY SECTION SCALEXT.S.0 CORNER HANGING ANGLE FLASHING RTU BASE RAIL 3/8" STAINLESS STEEL LAG SCREW THRU CURB AND RTU BASE RAIL ROOF CURB T 3/8" STAINLESS STEEL LAG STRUCTURAL SCREW THRU CURB JOIST ROOFS AND IRON BELOW ROOF FAN DISCONNECT, FACTORY WIRED TO MOTOR. CURB EXTENSION GALV. FU m WITCURBS Fin=E CM= THIS TYPICAL ASSEMBLY FR(�,�, �OPENI All SHALL OCCUR ON ALL FOUR OFROOFNG SIDES. MAX SPACING ON EACH SIDE SHALL BE 3'-0°. MIN 2 ASSEMBLIES PER SIDE. MIN. 1500' F GASKET ALL AROUND ANGLE BENDS A -A _ -12"----� EXHAUST DUCT A �` A ACCESS L-41 DOOR BOLTS ON 7" MAXIMUM CENTER NOTE: - ACCESS PANEL DOORS ARE CONSTRUCTED OF THE 16 GAUGE CARBON STEEL - GASKET IS RATED AT 1500 DEGREES F AND PANEL IS LIQUID -TIGHT - FASTENERS USED TO SECURE THE DOOR TO THE DUCT, DO NOT PENETRATE THE DUCT WALL EXHAUST SCALEXT.S. DUCT CLEAN OUT DOOR DETAIL GREASE DUCT AGENT SYSTEM CONTROL AUTO.._ WITH AGENT TANK ENCLOSED FireMasteraFastVVrap XL Commercial Kitchen Grease Duct Enclosure System Air Ventilation Duct Enclosure System 1 or 2 Hour Shaft Alternative / Zero Clearance to Combustibles Butt Joint / Overlap Butt Joint / Collar Option 3" (75) Overlap / 3" (75) Overlap Required for ULC Grease Duct Systems TWO LAYER INSTALLATION OPTIONS Telescope Wrap Option Butt Joint Option Checkerboard Wrap Option SINGLE LAYER OR OUTSIDE LAYER INSTALLATION OPTIONS System Details nr �N.u�i a Fx.n..w a�a sr.oen.. wNea a w wear aew „.wwm. FMXLM3 MANUAL PULL STATION W ¢QoL.LJ W _ I Z CD W N>N CL v O l� Ju� p=C.) I'-1 'ItN v d• O L..J ¢cnL�z w m��Nw� rOr►� O r� Oro M �p U w < C/)I¢—W Wa W = �'o ;Z �a zooz�Q z A �° QQDUJO (� !� 00 w pw Q W Z � o CZa�o:z¢ O L0 W z U_ 6• i J VA A•i 0 V•0 _J •. b'••••.....•• 0 ••. z CD col CD Of 0- Q CD J w Of o_ � M z � M Cn N Z o A � J a A kn W REVISION 1 1 2 3 4 I 5 6 7 I PROJECT TYPE: RENOVATION SCALE AS SHOWN ISSUED DATE: 03-08-2024 DRAWN BY: A. FEN G CHECKED BY: A. LI AN G SHEET M 3 E_==CTR CAE K. y rE: 1 /4„=1'-O„ P LA� I E i III I { IIi .i� iIl I f mbl r - i r jr_ B2� 'ItFCI B3 B2 J FCI /-B34 FCI KEF- B3 620 � FCI � KEF- B16,18 B3 B27 MUA-2 B22,24,26 FCI FCI WITRESS STATION j B3 FCI /-,B 3 4 0FCI B3 FCI �34 FCI EXISTING PANEL A O GENERAL ELECTRICAL NOTES: 1. ALL ELECTRICAL WORK SHALL BE DONE IN STRICT ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE EDITION 2020 2. WIRING SHALL BE INSTALLED IN METAL CONDUIT OR MC CABLE. WHERE SUBJECT TO PHYSICAL DAMAGE AND EXPOSE TO WEATHER, THE CONDUIT SHALL BE RIGID GALVANIZED. 3. ALL WIRES SHALL BE RATED FOR 600 VOLTS. MINIMUM CONDUCTOR SIZE SHALL BE AWG#12. COPPER WIRING UNLESS NOTED OTHERWISE. 4. PROVIDE GROUNDING IN ACCORDANCE WITH THE NEC. ALL BRANCH CIRCUITS SHALL CONTAIN EQUIPMENT GROUNDING CONDUCTOR. 5. ALL SWITCHES AND RECEPTACLES SHALL BE SPECIFICATION GRADE, IVORY COLOR. INSTALL 48" ABOVE FINISHED FLOOR AND OUTLETS AT 36" ABOVE FINISHED FLOOR. UNLESS NOTED OTHERWISE. 6. PROVIDE LIGHT FIXTURES PER THE FIXTURE SCHEDULE 7. PROVIDE ALL CIRCUIT BREAKER PER THE PANEL SCHEDULE. MULTI -POLE BREAKERS SHALL BE COMPLETE UNITS. 8. CONDUIT, ROOF AND WALL, PENETRATIONS SHALL BE SEALED AGAINST MOISTURE AND SHALL MAINTAIN THE REQUIRED FIRE RATING IN ACCORDANCE WITH UL SYSTEM 186. USE A UL APPROVED, FIRE RATED SEALANT SIMILAR TO DOW CORNING FIRE STOP 2000. 9. LIGHTNING PROTECTION AND BUILDING GROUNDING SYSTEM TO BE INSTALLED PER NEC, STATE AND LOCAL AMENDMENTS. ELECTRICAL SYMBOLS LEGEND MAY BE USED ON PROJECT NOTE - NOT ALL SYMBOLS SYMBOLS DESCRIPTION SYMBOLS DESCRIPTION DUPLEX RECEPTACLE, MTD. +18' AFF Q TRANSFORMER - SIZE AS NOTED 240 VOLT RECEPTACLE (HT. AS REQ.) PANEL - SIZE AS NOTED QUADRUPLEX RECEPTACLE, MTD. +18" F F-FAN M- MOTOR COUNTERTOP HT. RECEPTACLE +42'~_2 CKT. HOMERUN (B INDICATES PANEL) '2" DESIGNATES CIRCUIT NUMBER llVJP/GFI DUPLEX RECEPTACLE - IN WEATHER � EXIT/EMERGENCY LIGHT W. BATTERY BACK-UP. { PROOF ENCLOSURE OR COVER, GROUND FAULT INTERUPTER. EMERGENCY LIGHT W. BATTERY BACK-UP. SINGLE POLE SWITCH, MTD +47" q=p REMOTE HEAD �2 DUAL SWITCH, MTD +47' ® 2X4 FLUORESCENT LIGHTING FIXTURE A DESIGNATES FIXTURE TYPE DIMMER SWITCH, MTD +47" ® NL FLUORESCENT LIGHTING NIGHT LIGHT O JUNCTION BOX, FLUSH IF POSSIBLE O RECESSED LIGHTING FIXTURE 8 DESIGNATES FIXTURE TYPE DISCONNECT SWITCH W/ STARTER ¢ HOOD LIGHT Eli DISCONNECT SWITCH INCANDESCENT LIGHT W/ 1DOW BULB C DESIGNATES FIXTURE TYPE o OCCUPANCY SENSOR ® CEILING MOUNTED WINDOW OUTLET ! ®E EXISTING ELECTRICAL FIXTURE KEY NOTE: 1. EXISTING AC SYSTEM NO CHANGE 2. EXISTING ELEC. RISER NO CHANGE. 3. EXISTING ELECTRICAL PANEL: A; C; NO CHANGE. - TO RECONNECT REPLACED BUFFET TABLE CIRCUIT TO EXISTING BUFFET TABLE CIRCUIT, CONTRACTOR SHALL RE -VERIFY EXACT ELECTRICAL SYSTEM ON THE JOB SITE. - TO RECONNECT REPLACED EXHAUST FAN AND MUA TO EXISTING CIRCUIT, CONTRACTOR SHALL RE -VERIFY EXACT ELECTRICAL SYSTEM ON THE JOB SITE, r Zw�oo l Q� Q I m F Qly- Cfi g W Q U Z m 0 d U Vcwr p Q U J :S O r- N --D w }- Q cn z zp `2 Or►� d O z mzim-:2 W p N W O V M M � m o N w O � � Or0 ``'U cn Q Q � cn Q W LAJ LLIoz' =v' ¢ W o Q 0 ooC)cn QQ�__jp o W O o F_ (��zz ♦•� G 4K ��� •, • �� . Q.•. , 27 �. z w �• rn co o O :w * H Q: z to O: Z. LJ Q • -J Z U) wl 1>�., �• .���•• z J Q 0 0- Q . I LLJ Q 0 -J w cl- 0 Q M c� � ll z o M w � o CL �7MN U" NW � I C REVISION 1 I 2 3 4 5 6 7 PROJECT TYPE: RENOVATION SCALE AS SHOWN ISSUED DATE: 03-08-2024 DRAWN BY: A. FEN G CHECKED BY: A. LI AN G SHEET E 1 Y �2 i U I_ HT N G PLAN SO a._E: 1/4"=1'-0" LIGHTING NOTES: 1. PROVIDE A MIN. 50 FOOT— CANDLES OF LIGHT ON ALL WORKING SURFACES IN THE FOOD PREPARATION AREAS, EQUIPMENT AND UTENSIL WASHING AREAS, AT HAND WASHING LAVATORIES, AND IN TOILET ROOMS. 2. PROVIDE A MIN. 20 FOOT— CANDLES OF LIGHT AT A DISTANCE OF 30 INCHES ABOVE THE FLOOR IN WALK—IN COOLERS AND FREEZERS, DRY STORAGE AREAS, AND IN ALL OTHER AREAS. 3. ALL LIGHTING FIXTURES AND LIGHT BULBS LOCATED WITHIN FOOD PREPARATION AND STORAGE AREAS SHALL BE SHIELD OR SHATTERPROOF. 4. ALL THE EMERGENCY LIGHTS MUST BE CONNECTED TO NO SWITCHED LIGHTING CIRCUIT. 5. THE CONSTRUCTION DOCUMENTS SHALL SPECIFY THAT DOCUMENTS CERTIFYING THAT THE INSTALLED LIGHTING CONTROLS MEET DOCUMENTED PERFORMANCE CRITERIA OF SECTION C405 ARE TO PROVIDED TO THE BUILDING OWNER WITHIN 90 DAYS FROM THE DATE OF RECEIPT OF THE CERTIFICATED OF OCCUPANCY. 6. CONSTRUCTION DOCUMENTS SHALL REQUIRE THAT WITHIN 30 DAYS AFTER THE DATE OF SYSTEM ACCEPTANCE, RECORD DRAWINGS OF THE ACTUAL INSTALLATION SHALL BE PROVIDED TO THE BUILDING OWNER, INCLUDING: — A SINGLE —LINE DIAGRAM OF THE BUILDING ELECTRICAL DISTRIBUTION SYSTEM AND — FLOOR PLANS INDICATING LOCATION AND AREA SERVED FOR ALL DISTRIBUTION. PER FBCE 405.6.4.1 LIGHT FIXTURE SCHEDULE QUAN TITY DSCRIPTION STATUS WATT SYMBOL 2X4 LED TROFFER LIGHT, 120V, 18 8 WATT LAMP. 3500K RELOCATED 54 2X2 LED TROFFER LIGHT, 120V, 18 WATT/LAMP. 3500K NOT IN USE 36 62 6" RECESSED LED DOWNLIGHT 3500K. NEW 18 O LITHONIA TYPE: 65BEMW OR EQUAL HANGING LED LIGHT 3500K. NOT IN USE 18 TRACK LIGHT NOT IN USE 36 SCONCE, DESIGNHOUSE: 573154 OR gD EQUAL NOT IN USE 18 EXTERIOR BACK LIGHT W/ BATTERY NOT IN USE 60 BACKUP 4 DAY— BRITE MCPHILBEN CXXL3RW EXISTING/NEW 5 z EMERGENCY EXIT LIGHT 7 HUBBELL LIGHTING, CU2SQB EMERGENCY EXISTING/NEW 2 BATTERY LIGHT � p w Q� "V Ld W¢UZmO � � v�w� m Ld � w J J O � F J LLJ 00 M Q U Z cn w � LLJ = cn�nw zW Q w z U z � o 0 n CD Ld �Q ,— � � N LLJ = zzzoo F— W 0 V;'lv rn •� o LL. O J� . Z' J ��•.> z cn 4(- CD Q z QI 0 �I Q Q I w N � zl Q M U7 z 0 U l CL U w LLJ O U cn w N W �' Ln �I 1� REVISION 1 1 2 33 44 55 66 7 PROJECT TYPE: RENOVATION SCALE AS SHOWN ISSUED DATE: 03_08_2024 DRAWN BY: A. FEN G CHECKED BY: A. LI AN G SHEET 91 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - --- - I -------------- I I I I 1 I I I �i I I I I gi gi I I gi I I i I 1 L_ J T i i L_ J L_ J T T i L_ J T i I I I r---� I-- I-- �-- I EXISTING TRANSFORMER F- - - - r- J - - - L - - - L — — J - - - - - - - - - - —I F 7 F 7 F EXISTING 24 HOURS TIME r I I I I I SWITCH WITH MANUAL OVERRIDE I - I r - - - - - - - - - - - - - - - - I EXISTING METER CENTER 120/208 I 120/208 I L J FOR GENERAL LIGHTING 120/208 1 I I 1 1 3�,4W I 1 1 �,3W 1 -I 1 �,3W 1 I I I EXISTING L- - - - - - - - - - - - - - - - - - - - - - - J I 200A I I 200A I I I EXISTING 24 HOURS TIME 1 200A I I MAIN 1 I 10K A.I.C. I 1 10K A.I.C. I L J SWITCH FOR TENANT SIGN 10K A.I.C. L_ J I I I SERVICE I I I 1 I 1 i i i i i i I M.C.B. M.L.O. M.L.O. 1 I 120/208 I I I I t-----J L----� I �----� 1 I 3�,4W 1 I I 400A 1 I L—T—T—J ---------L I I I I I I I I I I I I L — — — — I — — — — — J I 1 I I L--------------- I I 1 i I --------------------------- ALL ELECTRICAL EQUIPMENT I I :INDICATED BY A DASHED LINE ISI - EXISTING INCOMING POWER ------� I ----- EXISTING - TO- REMAIN - _-11 I EXISTING POWER RISER D AGRAM I EXISTING SERVICE GROUND, -= CONTRACTOR SHALL VERIFY SCALEKT.S. IN ACCORDANCE WITH NFC. �A EXISTING PANEL B 1 O 120/240 VOLT FED BY 200 AMP BUS 136 AMPS M.L.O. BREAKER INTERRUPT RATING: EXISTING A.I.C. 144 AMPS NOTES: kVA kVA CKT CKT kVA kVA WIRE COND A 0 Bo C'B NO. NO. CJB A 0 B 0 LOAD DESCRIPTION SIZE SIZE 15.60 kVA (CONNECTED) )TAL 32.60 kVA (CONNECTED) )TALI 34.50 1 kVA (NEC220) DND SIZE WIRE SIZE LOAD DESCRIPTION 2 1 P-20 1.00 IXLGT-KITCHEN IX 4 1 P-20 RECEPTION 2#12 V2" 1_ EX EX STORAGE & RESTROOM 1 P-20 51.6 1 P-20 EX RECPT-SHOW WINDOW IX 1 8 n 1P-20 EX LGT-WALK-IN UNITS IX t EX IX LGT-HALLWAY 1P-20 �.10 2P-30 DISH WASHER 3#10 3/4" IX IX RECPT 1 P-20 12 - 3#10 3/4" 1/2" 2#12 LGT-DINING AREA 1P-20 n 14 EX LGT-EXTERIOR EX I/2" 2#12 LGT-DININGAREA 1P-20 16n 2P-20 KEF-3 3#12 3/4" rr 17 18 ,-� - 3#12 3/4" IX IX EMERGENCY LGT 1 P-20 ..... 19 20 ,---- 1 P-20 KEF-4 2#12 1/2" 2" 2#12 HOODCONTROL 1 P-20 n 21 22 2P-30 MUA-2 3#8 3/4" 23 24 3#8 3/4" EX IX STORE SIGN 1P-20 25 26 n 1P-2C - 2#12 1/2" 1/2" 2#12 RECPT- WAITRSS STATION 1 P-20 27 28 1 P-20 RECEPT-COOKING LINE 1 2#12 1/2" 1/2" 2#12 HIBACHIAREA 1P-20 29 30 1P-20 RECEPT-COOKING LINE 2 2#12 1/2" 1/2" 2#12 HIBACHI AREA 1P-20 n 31 32 1P-20 RECEPT-COOKING LINE 3 2#12 1/2" �1/2" 2#12 ICE CREAM FREEZER 1 P-20 33 34 1 P-20 RECEPT-COOKING LINE 4 2#12 1l2" v1/2" 2#12 BUFFETTABLE 1P-20 35 36/� 1/2" 2#12 SODA DISP. 1PL20 n 37 38 —1/2" 2#12 BUFFET TABLE 1P-20 n 39 40� / 41 42 / 43 44 En / / n 45 46 � ! 47 48 � / 49 50 - /� 51 52 F.T.L. CONNECTED LOAD: w)TAL FEEDER CALCS I FR NEC ARTICLE 220 LIGHT RECEPT KITCHEN COUNT 0 REFRIG FIRST 10 KVA@100% + 50% REMAINING 0/0 LOAD % LOAD 7.0 kVA CONTIN 125% 2.5 kVA 2.3 kVA NON-CONTIN 100% 0.0 kVA 14.3 kVA HVAC 100% 8.4 kVA 0.0 kVA TOTAL FEEDER LOADF 4.5 kVA 100% 100% w o QLi T l J Q Q Z 1� � z� (D w Q Z m 0 U U J U J U Q U O O Lim N w M M m o w CD w J J M¢ J U w<c w 0:: w Wo0oo �EsC)Z(nQ ¢QooJo CD Lj �zzoo C/) 00 u") W CD = Z ¢ 00 fA •� 0 0 : J% 'LU C7 1 Lij 01< -2: . U Q O. Z. % •� 0 .> z U) cc; ��; <5 6%•. . Q 0 ¢ w 0 w N d' W � J z M o M 0 U W 0 u p••, W M N V w REVISION 1 2 3 T 5 1 6 7 PROJECT TYPE: RENOVATION SCALE AS SHOWN ISSUED DATE: 03_08_2024 DRAWN BY: A.FENG CHECKED BY: A.LIANG SHEET ------------ , I+j _ 11; ; II I f I l � 4 1E4 I I 7�j if I I I( �a LitJl•- t F F FABLE "+..: FF"E-7 7A,,B_ E BlU I• t T iAi.j ILL 2' , et 3'_ �3./ EXISTIN T. I F U. i{ j 3 I 3' EXISTING! - - - HAND / - SINK I� ( Q3• 3'—� ! EY,f C'; 11 ! WA-iRESs I j H.D. 1 i j TO CONNECT TO EXISTING 3" GREASE LINE, CONTRACTOR AJ i SHALL RE -VERIFY EXACT LOCATION AND --- .TING EXISTING EXISTING SIZE ON THE JOB -- H.D. H.D. H.D. SITE TD. lll1� 3' I j --J ----- --- r IEj i !iI Ij i {ii I I !ff _-•'�1 S/'I'�ITARY PLAN SCALE: 1 /4"44' TO EXISTING 3" GREASE LINE 1[i f ppi`` I �_- ii{ ., SIZING FORMULA FOR RESTAURANTS USING FAC 64E-6.013(7) D1 & D2 VOLUME BASED ON SEATS: PUMP OUT FREQUENCY = 60 DAYS EFFECTIVE CAPACITY OF GREASE= S X GF X HR/12 X RF WHERE: S= # OF SEATS = 160 HR= 10 HOURS PER DAY GS= 25 GALLONS PER SEAT RF= 0.75 EFFECTIVE CAPACITY OF GREASE=1 60 X (10/ 12) X 25 X 0.75 —2500 GALLONS PROVIDED CAPACITY OF GREASE=1 X2500 =2500 GALLONS EXISTING 3' G.W. I I Nr 2" i� 2- 2'u TO EXISTING 4" SANITARY LINE, CONTRACTOR SHALL RE -VERIFY EXACT LOCATION AND SIZE ON THE JOB SITE 'TING; c001-ER STOR° -F J- VVi LK 1` rREU R X:5, ry , Kfl HG N i IRi11 ilfl I �� � I li ( 0m -_ - V) TO CONNECT TO I I m 0 EXISTING 4" GREASE 6 Z N LINE, CONTRACTOR I I m o SHALL RE-VERIFY----__—_j - T EXACT LOCATION AND I r 1 I SIZE ON THE JOB -_ f n, s _E SITE. EXISTING 4" GREASE LINE,CONTRACTOR p ' SHALL RE -VERIFY EXACT LOCATION AND SIZE ON THE JOB SITE L ' fl) I + EXISTING 3' G.W. nD N",'> CT!ON j EXO71NG 4" G.W. ea ; EXISTNrG 4" G.W.--- TO EXISTING 4" GREASE LINE � I -__� -'-- TO CONNECT TO 3' EXISTING 4" GREASE LINE, CONTRACTOR SHALL RE -VERIFY — EXACT LOCATION AND -- i6 - -' -- -+ -- I SIZE ON THE JOB EXI F.S. 3TI1G 2' SITE3. _ 2 w— O - 2sr PLUMBING SYMBOL SCHEDULE SANITARY WASTE LINE .............................. HOT WATER SUPPLY LINE -•-'-.- ................... COLD WATER SUPPLY LINE F.D. FLOOR DRAIN Q F.C.O. FLOOR/WALL CLEAN -OUT W.C.O. r�� F.S. FLOOR SINK H.D. HUB DRAIN ALL PLUMBING FIXTURES SELECTED BY OWNER SUBMIT CAT CUTS FOR APPROVAL (TO OWNER) WASTE PLUMBING NOTES 1. CONNECT NEW WASTE LINE TO EXISTING WASTE LINE BELOW FLOOR. CUT EXISTING FLOOR TO INSTALL, & PATCH FLOOR TO MATCH EXISTING CONSTRUCTION. 2. EACH WELL OF A MULTIPLE COMPARTMENT SINK SHALL DISCHARGE INDEPENDENTLY TO A WASTE RECEPTOR. 3. TO INSULATE DRAINS AT PUBLIC LAVATORIES. PER ACCESSIBILITY 606.5 NEW PLUMBING FIXTURE SCHEDULE ALL EQUIPMENT ARE TO BE INDIRECTLY DRAINED EXCEPT HAND SINKS, LAVATORY, MOP SINK FIXTURE MANUFACTURE TYPE MODEL DESCRIPTION PIPE SIZE REMARK TRAP WASTE VENT C.W. H.W. W.C. AMER STAND CAD 17"H EL 16/PA 3042.109 4086.800 P.A. FLUSH TANK 1.69 GPF 392 211 1 /2» 17" HIGH ELONGATE BOWL; TANK W/RIGHT HAND FLUSH LAV. AMER STAND LUCERNE 355.012 METERING FAUCET T&S B-0712 OR EQUAL 1-1/4" 2" 2" 1 /2" 1 /2" MTG. RIM 34" AFF. HOT WATER SUPPLIED TO LAVANTROY FIXTURES SHALL BETWEEN 85'F TO 109E HAND SINK REGENCY HAND SINK 600HS12SP FAUCET & DRAIN INCL. 1-1/4" 2" 2" 1/2" 1/2" 3-COMP SINK REGENCY 3-COMP SINK 60OS318242G 1-1/2" 3" 2" 3/4" 3/4" 2-COMP SINK REGENCY 2-COMP SINK 60OS218242G 1-1/2" 3" 2" 1 /2" 1 /2" DISH WASHER JACKSON DOOR TYPE CONSERVER XL DRAIN 2" 3" 2" 1 /2" 1 /2" C.O. J.RSMITH CLEAN OUT 4710-U 3" 2" F.D. J.RSMITH FLOOR DRAIN FD2370 1-1/4" 3" 2" F.S. ZURN FLOOR SINK FD2370 3" 2" r� W r a�¢oo , l 1��l Z U' OWN>W QCD r.l W mCD UJWOQFU O C7 M M m WNlOo�w � M d' Z U Q w~wwaw 0 �QQW)uJO oo O c� LLj 00 Ln aQ N 0 •7- •••......••••, Ln .iCD y� O uj •% O Z �•Q• ___I I �'•• ••��jj���! ,� •. b'••••.....••' `` .•` Ra•• some • z U cn Q 0 Q 0 J W d d' M M o U ZD 1.4 z o M CIO Q J A to 1•�1 � 0 11 d REVISION 1 I 2 3 4 5 6 7 PROJECT TYPE: RENOVATION SCALE AS SHOWN ISSUED DATE: 03-08-2024 DRAWN BY: A. FEN G CHECKED BY: A. LI AN G SHEET p 1 i 1/2' G.W. i i __jc /; 3 v; 3 /) I ki 1 1/2• H.N. C, -- 1C.W. 0_ 3 i A! 1 E-X I S TIIN! .: lIF F i 1431t x 3/4* H.W. MITER SUPPLY PLAN SCALE: 1/4"=1'-0" EX! c,-T I W, VVAI T RES's C.W. WOMIEN f 1/2- 1/2' 1/2' 1/2' 1/2' C.W. c.w. li H.W. C.W. H.W. - x i I j I x r _1 ' _ x _._ 1%'.W. ,1/2' C.W. 0''1/2' H.W. 314" H.W. /4',H.W. 13/4' C.W. 3/4' C.W. I 3s c;i s I cu 1/2- C.W. °E1H.- I I t ',;f rc t .j { t I -AB E i v i i { i� F R F E E 3 I s ci 1/2' C.W. 1/2' H.W. 3/4' C.W. �Il;lliillI O 3/4' H.W. I'11�lllii 3/4' C.W. 1/2" H.W. C 0 3/4' H.W. 1/2";C.W. 3/4' C.W. H.W. 0 3/4' H.W. 1' C.W. - CONNECTED TO EXISTING 1" I' COLD WATER SUPPLY LINE. - —" CONTRACTOR SHALL RE -VERIFY EXACT LOCATION AND SIZE ON THE JOB SITE I; 1/2' H.W. C 1/2' C.W. FF xI i1/2'IH.W.0 I :1/2"! C.w. j, i I' 1/2' H.W. C I 1/2' C.W. C ' 1/2' H.W. -- + 1/2' C.W. 1/2' C.W. _ 3'1/2' H.W. - 3/4' H.W. 1• C.W WATER PLUMBING NOTES 1. CONNECT NEW HW AND CW SUPPLIES TO EXISTING PIPING ABOVE CEILING. 2. PROVIDE INDIVIDUAL BACKFLOW PROTECTION FOR ALL WATER OUTLETS CONNECTIONG DIRECTLY TO ANY MIXING, BREWING, DISPENSING APPLIANCE, SODA, FILTER, ICE MAKER, DEVICE OR APPARATUS AS REQUIRED BY FLORIDA BUILDING CODE PLUMBING 608.3 AND 608.15 3. PLUMBING MATERIALS: COLD WATER-CPVC. PIPING HOT WATER- CPVC PIPING SANITARY- PVC PIPING GAS- METALLIC U¢ � o a Q Zo�¢WmW u V C7�WfWLLJ >W 'V O LZ��¢ ppm0 rr ll^ ^� V O [� �y�U� JWOQ ��--���m=O F�-1 cV O �t O ZU W >_¢Nz� w 00cZo�v�w� 0 cn ch m pNop�w a J 00 W c W N Z w '� apC-D� c) z�zin¢ ¢ ¢ p OJ l--I U O Ld Z ~ ¢ N Ld O6 Z Z rn O Ui P " v rn I.I.. 6-• J O; • :coO "w J• �, � • 'U • �c w O•• Z• W Q J •� ;Z zO � ;> . F vim• cn Q; � Q LJ •• 1 yI••• cf).• ••......•• ,� •••I . •• I .��'••.. 1 . , `..pR•', Z C7 V) 0 clf CL W Q W Q 0 mg J W CIA lqt ZZD zo M Z M o � J v I W W oC Lu O W a d REVISION 1 1 2 1 3 1 4 5 6 1 7 I PROJECT TYPE: RENOVATION SCALE AS SHOWN ISSUED DATE: 03-08-2024 DRAWN BY: A.FENG CHECKED BY: A. LI AN G SHEET S� OAS 09 xt G� 0PG ��Q1 Q � S�tiZO -'F s/29Zo 1 � ? V osoc. �c �Pei oor- t, 4� • \ O�\� .,yam J � ma's. per. 'S'.Jr. 1== 0113 NG SUPPLY RISER DIAGRAM ALE:N.T.S. so Ors O-sr p mot. '9f.. ojs \ y� }I �sy 4;' . V I/ �O / s i �? y s�y� o�A •�0. J+ si3�C' T •s ZD . y� T syT� � ti2��F`rS s O �20 < ai 2 "V. -,2 "V. Z. �L 2"V. i I I 1 2 "V. r.1.. 2"V. O ST O yF��"gICT� 2�F`C� 2"V. 2"V -quo sy s T � _ O s. voe �tio , 9 0 �9 TOE 2 "V. T 0 9�Q F lF G�Q�/STC'O o� F i 2 "V. �L FLUV,IIBIIJG SANITARY RISER DIAGRAM SCALEXT.S. J Q�Q fmuj 1�1 Q Jp�Q� Z c D pW(nvi W m O pQ�U I••-1 Fi''� �y O ``' >- Q z o W m U' ( W TO�hr•� enp�pp� n W m J l V) QQ(n�Q W Q W F-' W W N9a F7{ U zW 1—/]71 O � = eC-5 p p 0 cn N Q Z UZ Q Q cm V Q 1•„'1 W 0 0=�Z¢ N _ WZ~F- T� A V a w oo U) rn O d- Ln LL :C' o :(':W .V H O•z• W � •i O • �j% �. vO• W • . L¢ 11 •• •[r.Gj46 ,i • �% •. b''•••....••Rp .•` Z J 0 W a. W F- 1 0 mg J W W N pC P1 M � o '- M Q U o as W 1.4 F�•1 0 W J 0 CL L7cnNa W a_ REVISION 1 I 2 3 4 555 6 7 PROJECT TYPE: RENOVATION SCALE AS SHOWN ISSUED DATE: 03_08_2024 DRAM BY: A.FENG CHECKED BY: A.LIANG SHEET C,t,,S RISER SCALE: N.T.S. 0 �Qp do DIAGRAM SEDIMENT TRAP 7 GAS PIPING CALCULATION BASED ON TABLE 402.4(2) OF 2020 FBC—GC TOTAL RUN FROM POINTS OF DELIVERY TO THE REMOTE OUTLET(FT):115' TOTAL BTUH= 1,920K NOTE: (2020 FBC—FUEL GAS CODE, SECTION 410.2) 1. A TEE FITTING WITH ONE OPENING CAPPED OR PLUGGED SHALL BE INSTALLED BETWEEN THE MP REGULATOR AND ITS UPSTREAM SHUTOFF VALVE. SUCH TEE FITTING SHALL BE POSITIONED TO ALLOW CONNECTION OF A PRESSURE —MEASURING INSTRUMENT AND TO SERVE AS A SEDIMENT TRAP. 2. A TEE FITTING WITH ONE OPENING CAPPED OR PLUGGED SHALL BE INSTALLED NOT LESS THAN 10 PIPE DIAMETERS DOWNSTREAM OF THE MP REGULATOR OUTLET. SUCH TEE FITTING SHALL BE POSITIONED TO ALLOW CONNECTION OF A PRESSURE —MEASURING INSTRUMENT. GAS CALCULATION NO. QTY. DESCRIPTION BTUH(BTU) TOTAL (BTU) GAS SIZE 1 1 RICE COOKER 35K 35K 3/4" 2 1 7-CHINESE WOK 700K 700K 1-1 /4" 3 3 DEEP FRYER 110K 330K 3/4" 4 1 CONVECTION OVEN 108K 108K 3/4" 5 1 GRIDDLE 150K 150K 3/4" 6 3 EXISTING WATER HEATER 199K 597K 3/4" TOTAL 1,920K U (3. p W Z _ Q Q J O F- Q �' Z C.D p W N w Wy °v n n � Wa=pmO U Z J W O Q� U U O t� U p`p�U M�1 �r c `J c Ln z o W 0°��NW� rO►� O V M M m p N p p= W 00'* M N '� Q N m Q W Q (WE3W WZ>2 U . z w O Q = c��ac�Z : zooz�¢ � ¢ < C) O 0-0 1­4 W �, ¢ CD AU` a5400 rn C) 0 .•` bl� '•. �' C� •y:� z 4 N �•;�. Q . �'• w •sss • ��C. • z J Q d d Q W Q p mg J L.41 m M U C!) Z O U � a � � WW n F r- � wa a L`7 cn N REVISION 1 1 2 33 4 I 55 66 7 I PROJECT TYPE: RENOVATION SCALE AS SHOWN ISSUED DATE: 03-08-2024 DRAWN BY: A.FENG CHECKED BY: A.LIANG SHEET GWH GWH GWH HW CW HW CW HW CW I I i I i i E3h E3-i E)-i E�h @h E3h T HW I T T CW HWR WATER HEATER NOTES: HWR UP TO FAUCET CONNECTIONS THERMAL METER,,' i' _--- PROVIDE ESCUTCHEONS AT WALL \ I N I rl C PENETRATIONS. (TYPICAL) LL � � � U NOTE: rl� I 1.THE THERMOSTATIC MIXING VALVE THAT CSAB125.3. WATER TEMPERATURE SHALL NOT EXCEED 110 DEG F. WATTS MMV-M 1 (OR EQUAL) FOR SINGLE SINK APPLICATIONS. SUPPLIED WITH REMOVABLE POSITION AND THERMAL METER, SEPARATE CHECK STOPS, ROUGH BRONZE FINISH. INSTALL IN SUPPLY PIPING BELOW FIXTURE. SET TEMPERATURE AT 110'F MIXING. MIXING VALVE PIPING SCHEMATIC SCALE: NONE 1. WATER HEATERS SHALL BE INSTALLED PER MANUFACTURERS INSTRUCTIONS. 2. PROVIDE A TEMPERATURE AND PRESSURE RELIEF VALVE FOR EACH HEATER SIZED PER MANUFACTURER'S RECOMMENDATIONS. 3. COORDINATE INSTALLATION OF ELECTRICAL SUPPLY AND CONTROLLERS WITH THE ELECTRICAL CONTRACTOR. HWR COLD WATER SUPPLY 31ON TANK. L ST-25V. DASS BALANCING VALVE "B' BALANCING VALVE "A' BALANCING VALVE INSTRUCTIONS: 1. THERMOSTATIC MIXING VALVE DOES NOT OPERATE WHEN NO HOT WATER IS BEING DRAWN FROM THE SYSTEM. 2. TEMPERATURE CONTROL IN THE RECIRC LOOP IS ACCOMPLISHED WITH THE BALANCING VALVES. VALVES TO BE FULLY OPENED UPON SYSTEM SETUP AND CALIBRATED DEPENDENT UPON OWNER NEEDS. CLOSE VALVE 'A' IF THE HOT WATER IS SPIKING TOO HIGH, CLOSE VALVE "B" IF THE HOT WATER IS TOO COOL. GAS WATER HEATER PIPING DETAIL N.T.S WALI SAWANIFOLD-SEE PLUMB &OPT&S HOSE 1 BALL VALVE 3OW QUICK DISCONNECT EQUIP. GAS NIPPLE ELBOW RESTRAINING CABLE BOLT TO WALL STUD & EQUIP. FRAME GAS QUICK DISCONNECT DETAIL SCALE: NONE 3—COMPARTMENT SINK DETAIL SCALE: NONE HW ritil HWR�/ AQUASTATf CLOCK TIMER. LL VALVE TACO MODEL 563. \ I—,q—fit- HWR BALL VAL 1 TACO 0011#3 HOT HOSE BB WATER RECIRC. CHECKA A"E PUMP (T)O) \ (115 116 HP) AQUASTAT INSTRUCTIONS: \ / 1. THE TACO AQUASTAT MODEL 563 MOUNTS ON ANY "00" SERIES CIRCULATOR. REF MANUFACTURER FOR FURTHER INFORMATION. 2. SET AQUASTAT CLOCK TIMER TO RUN THE RECIRCULATION PUMP DURING FACILITIES HOURS OF OPERATION. COORD. W/ OWNER. 3. OPTIONAL TEMPERATURE CONTROL SETTING FOR THE AQUASTAT TO RUN THE RECIRCULATION PUMP WHEN TEMPERATURE IN THE PIPE IS BELOW 115" 4. THE CLOCK TIMER IS THE PREFERRED METHOD OF INSTALLATION FOR ALL HWR LINES AND THE ONLY OPTION OFR ALL HWR 140" LINES N v- 4" ROOF DECK ROUTE VENT PIPING IN CEILING SPACE TO TERMINATE VENT A MINIMUM DISTANCE OF 10' FROM FRESH AIR INTAKES • ' • - ' a ISHII �I ;I 1� VENT PIPE ROOF MASTIC ROOF DECK PACK W/ OAKUM OR EQUAL MATERIAL TO PREVENT ASPHALT DRAINAGE VENT THRU ROOF DETAIL SCALE: NONE CLEANOUT & ACCESS COVER TO BE FLUSH W/TOP OF FLOOR FINISHED FLOOR 1/8 BEND SOIL PIPE. Y BRANCH SOIL PIPE. C.O. NOT TO BE LOCATED IN CARPETED AREA. SANITARY CLEANOUT TO FLOOR SLAB SCALE: NONE AS NOTED HUB DRAIN AND STANDPIPE SCALE: NONE CAST BA"" TILE, 1/4' SLOPE N LATICRE WATERP MEMBRA EPDXY C DRAIN W COLLAR FLOOR SLEEVE SLAB(T FLOOR DRAIN DETAIL SCALE: NONE SELF PRIMING TILE, SLOPE 1/4"/FT. WATERPROOF MEMBRANE CAST IRON HALF GRATE - DOME STRAINER CLAMP RING ----i� FOR SINK SIZE AND TYPE, SEE PLUMBING FIXTURE SCHEDULE AND SPEC. FLOOR SINK DETAIL SCALE: NONE TYPICAL TRAP PRIMER DETAIL SCALE: NONE L o ►-� Q Jp!—QCL' zoWv W 8ma m�a-U U W pQ �;kj of ,- FN Uz 1-4 �NU' mM, ¢ �zCwl W C.DtW Ov M M m �N4pp�w [� M @ ¢QN�QLJ ¢ W W W rZ W X �_ U O 00 zooz�n¢ N QQ oV-JO (+1 0 W W �/ Q 0 c Qj a � AV Q,W,o0 Nj�Za rn C- 0 LLJ Im y O v ' J: cD * ~ p z: z w (1)(C,' i J loI %•• • J� W �I •• .• Lr) R •• z cn Q 0 Q W a 0 J W M U aC) 'Q Z U 1.4 ,1--11 V WW 64 L7c�N �a ❑ REVISION 1 1 2 3 4 1 5 1 6 1 7 1 PROJECT TYPE: RENOVATION SCALE AS SHOWN ISSUED DATE: 03-08-2024 DRAWN BY: A.FENG CHECKED BY: A.LIANG SHEET 5