HomeMy WebLinkAbout37915 Eiland Blvd (2)CHANGE OWNERSHIP OF AN EXISTING RESTAURANT GOLDEN PANDA RESTAURANT 37915 EILAND BLVD, ZEPHYRHILLS, FL 33542 ":.ALE: N.T.S. SHEET INDEX 01 COVER SHEET D1 DEMOLITION PLAN Al FLOOR PLAN Al-1 EQUIPMENT PLAN A2 LIFE SAFETY PLAN A3 REFLECTED CEILING PLAN A4 ARCHITECTURAL DETAIL A5 ARCHITECTURAL DETAIL M1 IHVAC PLAN M2 ROOF TOP EQUIPMENT PLAN I M3 HOOD DETAIL ' E1 ELECTRICAL PLAN '> E2 LIGHTING PLAN �Is E3 ELECTRICAL PANEL SCHEDULE > P1 ISANITARY PLAN '> P2 WATER SUPPLY PLAN ' P3 PLUMBING RISER P4 GAS RISER P5 PLUMBING DETAIL CODE CLASSIFICATION: 2023 FLORIDA BUILDING CODE -BUILDING (8TH EDITION) 2023 FLORIDA BUILDING CODE -EXISTING BUILDING (8TH EDITION) 2023 FLORIDA BUILDING CODE -ACCESSIBILITY (8TH EDITION) 2023 FLORIDA BUILDING CODE -ENERGY CONSERVATION (8TH EDITION) 2023 FLORIDA BUILDING CODE -MECHANICAL (8TH EDITION) 2023 FLORIDA BUILDING CODE -FUEL GAS (8TH EDITION) 2023 FLORIDA BUILDING CODE -PLUMBING (8TH EDITION) 2023 FLORIDA FIRE PREVENTION CODE (8TH EDITION) 2020 NATIONAL ELECTRICAL CODE PROJECT DATA: 1. TOTAL SQUARE FOOTAGE: 2. CONSTRUCTION TYPE: 3. USE/OCCUPANCY CLASSIFICATION: 4. FIRE SPRINKLER SYSTEMS: 5. BUILDING OCCUPANCY (PER 2023 [II 7 5,600 SQ. FT. III-B ASSEMBLY(A-II) NO FLORIDA BUILDING CODE(8TH EDITION)) OCCUPANT LOAD(PER FBC 1004.5) AREA PER CALCULATED SEAT SPACE DESCRIPTION SEATING TYPE AREA OCCUPANT OCCUPANT PROVIDED LOAD KITCHEN& SERVICE AREA 1451 SF 200 7 BUSINESS AREA(BUFFET AREA, RECEPTION) 1007 SF 150 7 BOOTH 168 LF 18" 112 84 DINING AREA UNFIXED TABLE 1504 SF 15 100 76 STORAGE 132 SF 300 1 WAITING AREA 42 SF 7 6 - TOTAL 233 160 NUMBER OF EXITS (FBC SECTION 1006.3) REQUIRED: 2 PROVIDED: 4 EGRESS WIDTH (FBC SECTION 1005.1) EXIT CAPACITY CALCULATIONS (DOORS) 233 X 0.25 (UNSPRINKLED)=58.25" REQUIRED MAIN EXIT PROVIDED: 64" > 29.125" (58.25"/2) (50% OF THE REQUIRED CAPACITY) OTHER EXITS PROVIDED: 128" > 29.125" (58.25"/2) (50% OF THE REQUIRED CAPACITY) TOTAL EXIT PROVIDED: 192" > 58.25" REQUIRED MAXIMUM EXIT ACCESS TRAVEL DISTANCE (FBC SECTION 1016.2) MAX. TRAVEL DISTANCE ALLOWABLE MAX. TRAVEL DISTANCE TO FRONT 38'-10" 80'-5"(<200') 200'-0" TO SIDE 55'-1 1 " TO BACK 47'-7" DEFERRED SUBMITTAL: 1. HOOD FIRE SUPPRESSION: HOOD FIRE SUPPRESSION CONTRACTOR SHALL SUBMIT FIRE SUPPRESSION SHOP DRAWING UNDER SEPARATE PERMIT. FIRE SAFETY NOTE: 1. FIRE EXTINGUISHER, PER 2019 N.F.P.A. #10. 2. KITCHEN SUPPRESSION SYSTEM PROTECTION, PER APPLICABLE PROVISIONS 2018 N.F.P.A. #96, AS MODIFIED. FINISH NOTES: 1. INTERIOR FINISH SHALL COMPLY WITH 2O23 FBC 801.2 & 2. EXIT ENCLOSURES AND EXIT PASSAGEWAYS: CLASS B CORRIDOR: CLASS B ROOMS AND ENCLOSED SPACES: CLASS C CLASS A: FLAME SPREAD 0-25, SMOKE DEVELOPED 0-450 CLASS B: FLAME SPREAD 26-75, SMOKE DEVELOPED 0-450 CLASS C: FLAME SPREAD 76-200, SMOKE DEVELOPED 0-450 3. ALL DECORATIVE MATERIALS SUSPENDED FROM WALLS OR 801.4 & 806. 4. WALL AND CEILING FINISH SHOULD MEET CLASS A, B, C, 5. FLOOR FINISH SHALL MEET EITHER: A) ASTM D 2859 FOR MATERIALS OR B) HAS A MINIMUM CRITICAL RADIANT FLUX CARPET FLOORING. PER NFPA. 101:12.3.3.5.3. 801.3, 803 AND 804. CEILINGS SHALL MEET FBC PER NFPA 101:12.3.3.3 CARPET AND CARPET LIKE OF .1 W/CM2 FOR NON 6. FURNISHINGS, DECORATIONS AND SCENERY SHALL MEET NFPA.101:12.7.4 GENERAL NOTES: 1. THE CONTRACTOR SHALL FIELD VERIFY ALL CONDITIONS AND DIMENSIONS PRIOR TO ANY WORK AND SHALL BE RESPONSIBLE FOR ALL WORK AND MATERIALS INCLUDING THAT FURNISHED BY SUBCONTRACTORS. 2. DIMENSIONS TAKE PRECEDENCE OVER DRAWINGS; DO NOT SCALE DRAWINGS TO DETERMINE ANY LOCATION. THE OWNER SHALL BE NOTIFIED IF ANY DISCREPANCY OCCURS PRIOR TO CONTINUING WITH WORK. 3. ALL CONSTRUCTION SHALL COMPLY WITH THE APPLICABLE BUILDING CODES AND LOCAL RESTRICTIONS. 4. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO LOCATE ALL EXISTING MECHANICAL AND ELECTRICAL SERVICES AND DISTRIBUTION SYSTEMS WHETHER SHOWN OR NOT, AND TO PROTECT THEM FROM DAMAGE. THE CONTRACTOR SHALL BEAR ALL EXPENSE OR REPAIR OR REPLACEMENT OF UTILITIES OR OTHER PROPERTY DAMAGED BY OPERATIONS IN CONJUNCTION WITH THE PERFORMANCE OF THE WORK. 5. ALL WORK SHALL BE ACCOMPLISHED WITH QUALITY WORKMANSHIP OF THE HIGHEST INDUSTRY STANDARDS. ALL MATERIALS SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURERS INSTRUCTIONS AND RECOMMENDATIONS. MATERIALS AND METHODS SHALL CONFORM TO THE APPROPRIATE NATIONAL TRADE BOOKS; I.E. TILE COUNCIL OF AMERICA, HANDBOOK FOR CERAMIC TILE INSTALLATION; ARCHITECTURAL WOODWORK INSTITUTE, "QUALITY STANDARDS." ETC. 6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR JOB SAFETY, AND SHALL TAKE ALL NECESSARY PRECAUTIONS TO ENSURE SAFETY OF WORKERS AND OCCUPANTS AT ALL TIMES. 7. ALL ELECTRICAL, MECHANICAL, AND PLUMBING WORK SHALL CONFORM TO STATE AND LOCAL REQUIREMENTS. 8. REMODEL WORK SHALL NOT OBSTRUCT, OR CAUSE TO BE INOPERATIVE, EXISTING FIRE PROTECTION SYSTEMS. MODIFICATION TO FIRE PROTECTION SYSTEMS SHALL BE PERFORMED BY A FIRE PROTECTION CONTRACTOR, WHO SHALL OBTAIN A PERMIT FROM FIRE LOSS MANAGEMENT PRIOR TO WORK. 9. DECORATIVE MATERIALS, DRAPES, HANGINGS, ETC., SHALL BE NON FLAMMABLE OR FLAME -PROOF PER STATE FIRE MARSHALL REQUIREMENTS. 10. MINIMUM FLAME SPREAD CLASSIFICATION OF INTERIOR FINISH SHALL CONFORM TO THE BUILDING CODE AND LOCAL GOVERNING BUILDING CODES/ORDINANCES. 11. FIRE SUPPRESSION CONTRACTOR SHALL SUBMIT SEPARATE PERMIT APPLICATION FOR APPROVAL. PLUMBING FIXTURE CALCULATION (PER FBCP 403.1) SPACE DESCRIPTION ASSEMBLY-2(RESTAURANT) TOTAL OCCUPANCY LOAD 233 SEX MALE 117 FEMALE 117 WATER CLOSET REQUIREMENT MALE 75 PER 1 FEMALE 75 PER 1 REQUIRED 2 2 PROVIDED WATER CLOSET 2 2 URINAL 1 LAVATORY REQUIREMENT MALE 1 PER 100 FEMALE 1 PER 100 REQUIRED 2 2 PROVIDED 3 3 SERVICE SINK REQUIREMENT 1 REQUIRED 1 PROVIDED 1 W-171 1 4, w( �w� o UJ Q�QLa Z Z�Lj Uj CD c) �¢ � U x o Ju�o�� z W �¢NZmID p w °°cZ'�cc-nw� �E) Ov M M m i-jNOo w QQV)O�w C, CYi Q N F- LJ W Z "E�c'Z QQcnU__jO �., O = z-zoo of Q� ar�oo N `n Q� �I :LLJ U p .z z ' 1' �/ J II Q 0 Q� w Q G -I w� OfI N 7t M � cn �ZW LV uj � Ln W W DC Q W LW U \ F / P= a- C7MN cn REVISION 1 1 2 3 4 5 6 7 PROJECT TYPE: RENOVATION SCALE AS SHOWN ISSUED DATE: 03-08-2024 DRAWN BY: A. F-EN G CHECKED BY: A.LIANG SHEET 01 - - _I ! I I I I It 7 1 GENERAL DEMOLITION NOTE: 1. THE FOLLOWING REQUIREMENTS FOR DEMOLITION, CUTTING AND PATCHING APPLY TO ALL WORK WHICH IS ALTERED, WHETHER SUCH WORK IS NEW, EXISTING, RENOVATED OR REPLACED: I 2. ASBESTOS SURVEY AND ABATEMENT: PRIOR TO DEMOLITION CUTTING TT NG OR PATCHING WORK, ENGAGE A LICENSED ASBESTOS CONTRACTOR TO PERFORM AN ASBESTOS SURVEY, WHICH IDENTIFIES SPECIFIC LOCATIONS WHERE ASBESTOS CONTAINING MATERIALS ARE FOUND, AND WHICH PRESCRIBES SPECIFIC I I ACTIONS REQUIRED FOR ABATEMENT. ENGAGE A LICENSED ASBESTOS ABATEMENT CONTRACTOR TO REMOVE OR ENCAPSULATE ALL ASBESTOS CONTAINING MATERIALS, ACCORDING TO THE EXISTING RECOMMENDATIONS OF THE ASBESTOS CONSULTANT. WHERE ASBESTOS CONTAINING MATERIALS ARE ENCAPSULATED IN THE BUILDING, PROVIDE THE OWNER WITH A DETAILED DESCRIPTION OF ALL ' °"Xio-°• REMAINING MATERIALS, INCLUDING LOCATIONS, APPROXIMATE QUALITIES, AND METHODS OF ECAPSULATED AND INSTRUCTIONS FOR NOT DISTURBING THE ENCAPSULTED MATERIALS. � I / 3. PRIOR TO DEMOLITION, CUTTING AND PATCHING, THE CONTRACTOR SHALL LOCATE AND DISCONNECT UTILITY SERVICES AND ELECTRICAL / MECHANICAL SYSTEMS, OR TEMPORARILY CAP OFF SUCH SERVICES 3 TO THE AFFECTED AREAS. GIVE NOTICE TO, AND COORDINATE WITH UTILITY COMPANIES. OBTAIN WRITTEN APPROVAL FROM, AND COOPERATE WITH OTHER PARTIES WHO MAY BE AFFECTED BY INTERRUPTION OF SERVICES. 4. CLEARLY MARK THE AREAS AND LIMITS OF DEMOLITION, CUTTING AND PATCHING. IF FEASIBLE, PRE—CUT THE LINE OF SEPARATION BETWEEN AREAS OF DEMOLITION AND AREAS TO BE PRESERVED. UTILIZE DEMOLITION AND CUTTING TECHNIQUES WHICH ARE LEAST LIKELY TO DAMAGE SURROUNDING OR w'wcR I'v ,s o°- ADJOINING WORK. WHERE FEASIBLE, USE HAND TOOLS AND SMALL POWER TOOLS THAT ARE DESIGNED FOR SAWING AND GRINDING, NOT HAMMERING OR CHOPPING. DO NOT USE EXPLOSIVES. S. STRUCTURAL REQUIREMENTS: DO NOT CUT AND PATCH STRUCTURAL WORK IN A MANNER WHICH WILL I 2 x REDUCE LOAD —CARRYING CAPACITY OR LOAD —DEFLECTION RATIO. WHERE STRUCTURAL WORK MUST BE X CUT, PROVIDE ADEQUATE TEMPORARY SUPPORT (BRACING AND/OR SHORING) TO RESIST VERTICAL, 1 I I LATERAL AND DYNAMIC LOADS IN THE ENTIRE TRIBUTARY AREA OF THE AFFECTED STRUCTURAL Rc"� X MEMBERS. WHERE REQUIRED, ENGAGE A LICENSED STRUCTURAL ENGINEER TO DESIGN SHORING / EXISTING EXISTING EXISTING BUFFET TABLE BUFFET TAB E BUFFET TAB E / / BRACING SYSTEMS AND JOINT OR CONNECTION DETAILS. --- - - 6. OPERATIONAL AND SAFETY LIMITATIONS: DO NOT CUT AND PATCH OPERATIONAL ELEMENTS OR SAFETY RELATED COMPONENTS IN A MANNER WHICH WILL REDUCE INTENDED PERFORMANCE OR SAFETY FACTOR, OR WHICH WILL RESULT IN INCREASED MAINTENANCE OR REDUCED OPERATIONAL LIFE. 7. VISUAL REQUIREMENTS: DO NOT CUT AND PATCH WORK IN A MANNER WHICH WILL RESULT IN II LESSENING OF THE AESTHETIC QUALITIES OF THE BUILDING OR SITE, OR THAT WILL RESULT IN VISUAL EVIDENCE OF CUT AND PATCH WORK. WHERE REQUIRED, EXTEND FINISH MATERIALS OVER ENTIRE N ,4 1XI UNBROKEN SURFACE AREAS AFFECTED BY CUT AND PATCH WORK. REMOVE AND REPLACE CUT AND PATCH WORK WHICH DOES NOT MEET VISUAL REQUIREMENTS. I 1 8. PROTECTION: PROTECT OTHER WORK DURING CUTTING AND PATCHING OPERATIONS TO PREVENT I� DAMAGE. PROVIDE PROTECTION OF ALL WORK FROM ADVERSE WEATHER CONDITIONS. WHERE OPENINGS ARE CREATED IN ROOF OR EXTERIOR WALLS, PROVIDE TEMPORARY ENCLOSURE OF SUCH OPENINGS ON A DAILY BASIS, AND WHENEVER ADVERSE WEATHER THREATENS OR EXISTS. ID 1 DE- O❑TON PLAN DEMl: _.ITION KEYED NOTES: I ) 1. _�'EMOVE EXISTING PARTITION AND COUNTERS. TO REMOVE UNUSED ELECTRICAL WIRING BACK 10 NEAREST JUNCTION BOX. 2. ' 0 REMOVE EXISTING HOOD SYSTEM IN THE KITCHEN AREA 3. -10 DEMOLISH EXISTING RESTROOM. 4. ='OWER PANELS TO BE REMAINED. 5. 10 STRUCTURAL WORK. 6. 1,CCUMULATION OF AMBULATION OF COMBUSTIBLE WASTE MATERIAL, DUST, AND DEBRIS SHALL ,E REMOVED FROM THE STRUCTURE AND ITS IMMEDIATE VICINITY AT THE END OF EACH WORK :.�HIFT OR MORE FREQUENTLY AS NECESSARY FOR SAFE OPERATIONS. NFPA 1:16.2.2.1 7. ,URING DEMOLITION EXITS AND FIRE SAFETY EQUIPMENTS SHALL BE CLEARLY VISIBLE AND ..iNOBSTRUCTED. 8. 7 XISTING CEILING SYSTEM TO BE REMAINED 9. =',NY STRUCTURAL WORK AND THE PROPOSED TEMPORARY BRACING TO MAINTAIN THE :TRUCTURAL INTEGRITY DURING CONSTRUCTION. ELECTRICAL DEMOLITION NOTES 1 . THE CONTRACTOR SHALL REMOVE ALL UNUSED AND ABANDONED WIRING AND CABLING FROM THE CEILING THAT ISN'T LABELED FOR FUTURE USE, AS REQUIRED BY THE NEC. THIS SHALL INCLUDE BUT IS NOT LIMITED TO FIRE ALARM, POWER, SECURITY, CONTROLS, DATA, TELEPHONE, A/C ETC. 2.CIRCUITS MADE SPARE SHALL BE UPDATED ON PANEL SCHEDULES. DIRECTORY CARDS SHALL BE REPLACED WITH NEW TYPED DIRECTORIES, INCLUDING ALL NEW LOADS IN ADDITION TO SPARES. HAND —MARKED NOTES WILL NOT BE ACCEPTED. 3.CARE SHALL BE TAKEN TO RELOCATE ALL EXISTING EQUIPMENT THAT IS BEING MOVED BUT REMAINING AFTER COMPLETION OF WORK. THE CONTRACTOR SHALL BE RESPONSIBLE TO KEEP ALL EXISTING TO REMAIN OR RELOCATED EQUIPMENT AT THE SAME LEVEL OF FUNCTIONALITY FROM THE ACCEPTANCE OF THE CONTRACT OF FINAL COMPLETION. ANY DAMAGE OR LOSS OF FUNCTIONALITY SHALL BE REMEDIED BY THE CONTRACTOR AT NO ADDITIONAL EXPENSE TO THE OWNER. 4.EQUIPMENT INDICATED TO BE REMOVED AND NOT RE —USED SHALL REMAIN THE PROPERTY OF THE OWNER AND RETURNED OR STORED AS DIRECTED. 5.CONDUITS AND RACEWAY SYSTEMS MAY BE ABANDONED WHERE CONCEALED HOWEVER SHALL BE REMOVED WHERE EXPOSED. REMOVED OUTLETS SHALL BE PROVIDED WITH BLANK COVERS, COLOR PER THE ARCHITECT'S DIRECTION. 6.EXISTING RACEWAYS AND WIRING ARE ALLOWED TO BE RE —USED PROVIDED THEY MEET THE SPECIFICATIONS FOR THE NEW SYSTEM(S). 7.ALL OUTAGES SHALL BE COORDINATED WITH THE OWNER. THE CONTRACTOR SHALL PLAN TO MINIMIZE ALL OUTAGES. 8.CIRCUITS SHALL STAY FUNCTIONAL WHERE DEVICES/FIXTURES ARE BEING DEMOLISHED THAT SHARE A COMMON CIRCUIT WITH DEVICES/FIXTURES THAT ARE TO REMAIN. WIRING SHALL BE REMOVED AS FAR AS POSSIBLE WHILE MAINTAINING EXISTING TO REMAIN OPERATION. 9.THE CONTRACTORS SHALL REMOVE ALL EXISTING ELECTRICAL EQUIPMENT NOT REUSED OR NOT NECESSARY FOR THE COMPLETION OF THIS PROJECT. U o Q� Zo�Q� 0p m O M M m w w J uj 00 d Cn ¢ U) uj ui 0 V) n¢ zw'�Q�wZ mEs Uz 00 ~ QQ JO Z W QC7aw� NNF�-ZZ < 0 �Q;.• ��2;� Q •�,; �(, of �• �. _ ul z :U O•LJ • I �i � y. O � -J Q ,'o Uj &all as U Q 0 Q Q 0 w � z Q M z z 0 U Z Q W z 0 W W J U O W tY w C� M N c REVISION 1 1 2 3 4 5 6 7 PROJECT TYPE: RENOVATION SCALE AS SHOWN ISSUED DATE: 03_08_2024 DRAWN BY: A.FENG CHECKED BY: A.LIANG SHEET ■yaw TAG LEGENDS D# DOOR TYPE TAGS(SCHEDULE SEE A3) 42, 7,-8„ 9,-7„ 1 0, 8,-3„ O WALL TYPE TAGS(DETAIL SEE A4) Z�Qw— IQ¢zwLLJ Q JpF—Q� wz<: : I I I� - - - WALL TYPE SCHEDULE U Q d W Q oo L - - - U /L� `"' x N w \ \ L_ / / — — — \ �— / ` - — - EXISTING FIRE WALL O M w o w cn w �.in—NOS EXISTING WALL 00 cf)m ¢ ¢ Ln Ld ¢ w ��-wwZ� _ Q U Ln EXISTING NEW WALL �C Q\.c W z U Z N WAITRESS I ID Cfl z W U 00 ~ O U O STATION 0--m= � 00 Cn LJ Q ¢ O J WOMEN - MEN EXISTING W O ¢ I CDN�ZZ III 1 :1 E :j E :1 EI' j ESTRQOM \ i _ _ RESTROOM STORAGE REPLACED 00 N a ¢ WALK-IN v FREEZER 5--J �_�� �� �� � �� 10'-O'x1o'-0• :1 E :1 c: O O I I •.,..t. \ \ ;, P•• �1, c �I :1 f D3 — � O O � — — � D3 D3 : ��� � • O V% : QI CD LLJ -11 L_ -- I G:) 46 E A E : •5 2 5 — 3 .,,17 * •_��,. goes n 4'-2 D3 x �x EXISTING W 1 i WALK-IN COOLER 19'-O" XS'-O" Z D2 Z EXISTING 1 MECH W 1 RO DM O .. I c c c Ti m m EXISTING ��� r- Cfl m m m- KITCHEN I O > I I co r- r r I 0 0 f ff CO m m m — 8 mm mn m ADA N ; COUNTER S.S. TABLE 3 f I I f I I J Q I I m I I 15 L co O 6' W1 c I I C I I Q f ,f , , „ , , » , n m I I Ji �— 5 5— 2 4 3— 6 4 3-6 g— 6 I CONVECTION �Tl OVEN i i I I ^ D I I I I CC) I I I I Q r I I I 6 m IF w i i Ln ^ —1 I I m I f QO A E III I il' � j ��� I :1 E :1 �-1 r r I II. I I O Ln! Q0 :1 W 0 LJ I I Ji !1 M U I I I —:1 E :1 --------- +--- N I I�L I I I �I III I :1 E :1 BUFFET10 :1 ETABLE mly-� h•�••I I I I I If'11 II""�"11 I c0ccco I I W1 = O ❑°' ❑°' ❑°' ❑°' W 1 cr a LIMN NL O I WAITRESS I ' REVISION STATION I I �W>- -----------------� 0 I d— 2 I 4 I D2 5 6 7 42' 7,-8„ 6,-8„ 21 f-6„ '— f, PROJECT TYPE: RENOVATION FL OR PLAN_ LAN 7810 SCALE AS SHOWN SICK.--L 1/4„1 1_011 ISSUED DATE: 03_08_2024 DRAWN BY: A.FENG CHECKED BY: A. LI AN G SHEET 1 I - -- I -- --� F wairRe STATION EL- EXISTING BUFFET TABLE ECG ., I P M ENT PLAN SCA..= 1 /4"=1'-0" EXISTING BUFFET TABLE EXISTING BUFFET TABLE WOMEN LRESTgQOM, I � 1 � , I ( 2 0 WAITRESS STATION MEN _ 1 RE STROOM 1 r y =EXISTING EXt� ST!NG�' STORAGE REPLACED ! WALK—IN FREEZER iO•_0„—xi 0_ _O" (i) EQLW" SCHEDULE EQUIPMENT SCHEDULE NO CITY. DESCRIPTION MANUFACTURE MODEL U.L.N S.F. ELECTRICAL GAS WATER WASTE VOLT PHS. HP. KW. SIZE BTUH C.W. 1H.W. DIR. INO. 1 3 HOOD ECON AIRE U.L. 2 1 HOOD ECON AIRE 3 2 RICE WARMER AVANTCO RCS860 N.S.F. 120 1 4 3 DEEP FRYER PTICO SG-16 N.S.F. 3/4"' 110.000 BTU 5 1 RICE COOKER RINNAI RER-55AS N.S.F. 1/2" 35,000 BTU 6 1 CHINESE STOVE WIN SUPPLY WR-700 N.S.F. 1" 700.000 BTU 1" 3" 7 1 GRIDDLE COOKING PERFORMANCE G60—NG N.S.F. 3/4" 150.000 BTU 8 1 CONVECTION OVEN COOKING PERFORMANCE FGC-200—NK N.S.F. 3/4" 108,000 BTU 9 2 WORKTOP COOLER AVANTCO SS—WT-72R—HC N.S.F. 115 1 1/3 0.59 10 2 SANDWICH UNIT AVANTCO C—SP72-16—HC N.S.F. 115 1 1/3 0.59 11 2 HOT HOLDING UNIT DELFIELD N8887 N.S.F. 208 1 12 2 COLD HOLDING UNIT DELFIELD N8081 N.S.F. 120 1 13 1 COLD HOLDING UNIT DELFIELD N8056 N.S.F. 120 1 14 1 ICE MAKER EXISTING N.S.F. 115 1 1.75 15 6 HAND SINK EAGLE/EXISTING HAS— 10—F—LRS N.S.F. 1/2" 1/2" 2" 16 1 3—COMP. SINK REGENCY N.S.F. 3/4" 3/4" 3" 17 1 2—COMP. SINK REGENCY N.S.F. 3/4" 3/4" 3" 18 1 REACH —IN COOLER AVANTCO GDC-23—HC N.S.F. 19 1 MOP SINK SELECTED BY OWNER N.S.F. 1/2" 1/2" 2" 20 2 SODA DISP. PROVIDE BY COCA —COLA N.S.F. 21 1 WALK—IN COOLER AMERICAKOOLER 19'—O" X8'-0"' N.S.F. 208 1 1/3 1.52 22 1 WALK—IN FREEZER AMERICAKOOLER 10'-0" X 10'-0" N.S.F. 208 3 1/3 1 23 1 REACH —IN COOLER AVANTCO SS-3R—HC N.S.F. 115 1 1/3 0.59 24 1 COUNTER CUSTOM 25 WALL MOUNTED SHELVE(Stainless Steel) EAGLE PWE-14-3S N.S.F. 26 LOT TABLE(Stainless Steel) EAGLE T3036, T3072 N.S.F. 27 LOT SHELVE(Stainless Steel) EAGLE 1842S N.S.F. 28 POS CUSTOM 29 1 DISH WASHER JACKSON N.S.F. 208 1 10.1 3/4•" 3/4" 3'" 30 1 SOLID TABLE EAGLE N.S.F. 31 1 CLEAN TABLE EAGLE N.S.F. 32 1 ICE CREAM FREEZER MASTER BILT MSF-71AN N.S.F. 115 1 1/3 0.59 33 2 DIP WELL 34 1 WATER HEATER RINNAI EU199 N.S.F. 3/4" 199.000 BTU 3/4" 3/4" FINISH SCHEDULE TOE BASE COVING FLOOR CEILING WALL DINING AREA CERAMIC TILE. CERAMIC TILE. 2X2 LAY -IN ACOUSTICAL CEILING, NON -PERFORATED, NON -FISSURED, GYPSUM FIRECODE PAINTED W/2-COATS SMOOTH, WASHABLE, LIGHT -IN COLOR. VINYL FINISH. OF EPDXY PAINT. 2X2 LAY -IN ACOUSTICAL CEILING AND DRYWALL CEILING, GYPSUM FIRECODE PAINTED W/2-COATS BUFFET AREA CERAMIC TILE. CERAMIC TILE. NON -PERFORATED, NON -FISSURED, SMOOTH, WASHABLE, LIGHT -IN COLOR. VINYL FINISH. OF EPDXY PAINT. TOILET ROOM CERAMIC TILE. CERAMIC TILE. EXISTING DRYWALL CEILING, NON -PERFORATED, NON -FISSURED, CERAMIC TILE FINISHED 4 FEET A.F.F. FIRECODE PAINTED W/2-COATS SMOOTH, WASHABLE, LIGHT -IN COLOR. VINYL FINISH. ,GYPSUM OF EPDXY PAINT. KITCHEN AREA QUARRY TILE. QUARRY TILE. EXISTING DRYWALL CEILING, NON -PERFORATED, NON -FISSURED, STAINLESS STEEL BEHIND HOOD AREA SMOOTH, WASHABLE, LIGHT -IN COLOR. VINYL FINISH. AND FRP PANELING IN OTHER AREA. FINISH NOTES: 1. ALL FINISHED SURFACES SHALL BE SMOOTH, EASILY CLEANABLE AND NON ABSORBENT. 2. ALL DAMAGE CREATED OR DISCOVERED IN THE PROCESS OF THE CONSTRUCTION PHASE OF THE PROJECT SHALL BE PROPERLY REFINISHED IN AN APPROVABLE MANNER. ALL SURFACE PENETRATIONS, CRACKS AND CREVICES ARE TO BE SEALED TO ELIMINATE VERMIN HARBORAGE AREAS. 3. ALL PLUMBING PIPES, ELECTRICAL CONDUITS, GAS LINES, ETC. SHALL BE KEPT WITHIN THE WALL CAVITIES, ABOVE THE CEILING OR UNDER THE FLOOR. IF THE GAS LINE MUST BE RUN OUTSIDE OF THE WALLS, THEN A CLEANALBE BRACKET MUST BE USED THAT WILL BRACE THE PIPE AT LEAST 1 " OF THE WALL AND AT LEAST AT 12" OFF THE FLOOR. 4. UTILITY LINES SHOULD BE STUBBED OUT OF THE WALLS, FLOORS OR CEILINGS AT EACH PIECE OF EQUIPMENT SERVED. U W J Q�¢Wim ¢ :3�1ZZ¢� C9pWN W S2 W o zQ-omuj U c t- Ju¢ �ppNU ICI (y V 0 c W = >- so W m A� S2 W O 0 M M m Ip�I��p� W JJ r� M zU W�—I ¢ IIam�roo Q—WLLJZ w = NC7rZ.pc9} 0 QQpoO (n W Z W � Q W 0 C=az cn 00 N °- ¢ L0 ••• sams• * •••� .'6•,cl- '��. �G •.. ... '•. CD • �v*� � • Q•�"�� J O• • U z O• z'LLJ k.- . ¢ • •. _j ILLj ••,fib''•••... : !. ••'pF�;.`. tis z ••..loss.••• C� cn J O 0 J W ' M o M Of h+�l zto Of O U 0-4 ~ z W w w � r� t= O� �w c w REVISION t 2 3 4 5 6 7 I PROJECT TYPE: RENOVATION SCALE AS SHOWN ISSUED DATE: 03_08_2024 DRAWN BY: A.FENG CHECKED BY: A.LIANG SHEET FE 15 EXISTING EXISTING EXISTiNC' Bt�FFET TABLE BUFh`E7 TABLE BUFFF TABL E E � / E ADA FE1 COUNTER o L, ww11- K E.T.D.=55'-11» ^` LIF= SAFETY PLAN v �at�rRe 51'ATIONs • LIFE SAFETY LEGEND — — — MAXIMUM TRAVEL DISTANCE DIRECTION OF EGRESS FE1 FIRE EXTINGUISHER (FE) a FE1 SHALL HAVE MINIMUM RATING OF 3A-40BC FE1 TYPE ABC PROVIDE 101 MULTI -PURPOSE FIRE a EXTINGUISHER MOUNTED WITH WALL HOOKS AT 48' AFF AND CERTIFIED FE-K TYPE K PRIOR TO INSTALLATION. TRAVEL DISTANCE BETWEEN FE NOT TO EXCEED 75 FT EXIT SIGN ®f DIRECTIONAL EXIT SIGN EMERGENCY LIGHTS STATEMENT: OUR DESIGN TO THE BEST OF OUR KNOWLEDGE COMPLIES WITH THE 8TH ED FFPC. ^ w U ll M�•i %w ¢ Q Z C 7 W N W_ W w¢�zm°d v`zp=U cn z �..� T N �� v 0 rI O w mo a—o w m_U' �cnW� OC7K,r, mW(ncma" WFW M u cn ¢J = to = o z z\o A o C05 Q¢oQ 0 oo ¢ N_ m (Duj W O CZ-=xzz '� AC7ar�00 �, a ¢ 0 t Ld .• 41, 0 ft �: % c� •:Z :(D:w Ul �Q: z .V z O.Z. w �. •. LLJ Sol s z sees J C) Of W rL Q w Q 0 J W Q' W ' M M o U Z Z CD O U n z z LL ww � a w O o r- � � 0- � C�MN �� ❑ REVISION 1 1 2 3 1 4 1 5 6 1 7 I PROJECT TYPE: RENOVATION SCALE AS SHOWN ISSUED DATE: 03_08_2024 DRAWN BY: A.FENG CHECKED BY: A.LIANG SHEET R..F---LECTED CEILING PLAN SCA..::: 1 /4"=1'-0" SYMBOL SCHEDULE MAY NOT USE ALL THE SYMBOLS ®2x4 SURFACE MOUNTED TROFFER FLUORESCENT LIGHT FIXTURE O CEILING MOUNTED LIGHT FIXTURE 2x2 SURFACE MOUNTED CEILING MOUNTED 6" DOWN LIGHT FIXTURE TROFFER FLUORESCENT LIGHT FIXTURE TRACK LIGHT FIXTURE SUPPLY DIFFUSER EXHUAST DIFFUSER RETURN DIFFUSER REFLECTIVE CEILING NOTES: 1. DROP CEILING HEIGHT IS SET AT 12'-0" 2. HARD CEILING HEIGHT IS SET AT 10'-3" 71� 12GA GALVANIZED WIRE I 0 48" O.C. 3/8"0 ZINC THREADED ROD 060" O.C. TYP, II � � I I y I 2X2 LAY -IN ACOUSTICAL CEILING 1/2" GYPSUM BOARD 3/8" METAL SCREW 024" 3 5/8" METAL STUDS O.C. TYP. 0 16" 0 C 1'-4" 4'-0" SOFFIT DETAIL 1 SCALEXT•S• EXISTING EXTERIOR WALL SOFFIT DETAIL 2 SCALEXT.S. EXISTING TRUSS P1000 UNISTRUT i EXISTING TRUSS, 3/8" DIA THREADED ROD TO UNISTRUT SEE DETAIL B DETAIL SCALEAT.S. P1000 UNISTRUT NUT FENDER WASHER ___3/8 yDIA THREADED ROD TO M ETALSTU D BDETAIL SCALEXT.S. ^ w M-� W z c�owcwn�w Of U Z Q U J U Q F- U J�� V V x I --I (� �N w ¢ N z 0 mCZ'���(J7F- O OLLj M M w m N O o� w 00 ct v� Q¢cn�~w w~ w w¢ W ooC-) QQoo ;o wzl-F O = z—zoo 00 0 d- ,,���� a .����• ••• J c> Ali LL �- : : J o . -cD;WLo �W �'Q- w - .0 Q O• Z: J I C-3 J Q 1 % ' W • :J z Q 0 a_ Q_ Q Q 0 Z J g a z ^: F—I M (D o Z M--i 0 QQ� w V Z � Z � � W r=W Ln O W W Ln REVISION I 1 2 1 3 4 1 5 6 7 I PROJECT TYPE: RENOVATION SCALE AS SHOWN ISSUED DATE: 03_08-2024 DRAWN BY: A.FENG CHECKED BY: A. LI AN G SHEET Er `� FOOD PAN m O STAINLESS STEEL N ',.OVER 3/. PLYWOOD BUFFET TABLE SNEEZE GUARDS REQUIREMENTS: (PER NSF STANDARD #2) - ALL BUFFET TABLES MUST BE COVERED TOPS, SIDES & FRONTS. - MINIMUM COVERAGE FRONT/SIDES 18" @ 30-45 DEGREE SLANTED GLASS - CAN NOT EXCEED 13" ABOVE COUNTER SLANT - BOTTOM LEADING EDGE OF THE FOOD SHIELD SHALL EXTEND A MINIMUM HORIZONTAL DISTANCE OF 7" BEYOND THE FRONT INSIDE EDGE OF A FOOD WELL TEMPERED GLASS & TEMPERED-- STAINLESS STEEL GLASS SNEEZE GUARD ,Ig 2 ro 3/4" GRANITE j cn COUNTER TOP STAINLESS STEEL - OVER 3/4" PLYWOOD _ 3/4" PLY. WOOD 2"X3" WOOD STUD N 2"X4" WOOD STUD @24 O.C. STAINLESS STEEL LEG I- ffET TABLE DETAIL. LE:N.T.S. - Stainless Steel Channels TEMPERED GLASS TEMPERED GLASS & STAINLESS STEED, SNEEZE GUARD m 3/4" GRANITE g COUNTER TOP J <c - STAINLESS STEEL _ OVER 3/4" PLYWOOD 3/4" PLY. WOOD N 2"X3" WOOD STUD- 2"X4" WOOD STUD @24 O.C. STAINLESS STEEL LEG FOOD PA STAINLESS STEEL OVER 3/4° PLYWOOD,_ N DOOR SCHEDULE NO. MARK SIZE MATERIAL FRAME FINISH RATING REMARKS 1 STORE FRONT 3'-0" x 7'-0" x 1 3/4" EXISTING ALUMINUM& TEMPERED GALSS ALUM BRONZE — PANIC HARDWARE IS REQUIRED 2 STORE BACK, SIDE 3'-0" x 7'-0" x 1 3/4" EXISTING HOLLOW METAL METAL PAINT — PANIC HARDWARE IS REQUIRED STORAGE, RESTROOM, ADA COMPLIANT "MEN" 3 KITCHEN, 3'-0" x 6'-8" x 1 3/4" EXISTING HOLLOW CORE WOOD WOOD PAINT — &"WOMAN"SIGN MOUNTING MECHANICAL ROOM I I I HEIGHT@ 48" AFF DOOR NOTES: 1. LATCH SIDE CLEARANCES AT ALL DOORWAYS SHALL BE IN ACCORDANCE WITH FBCA, SECTION 404.2.4 2. ALL EXITS TO BE LABELED. 3. INTERIOR DOORS TO BE LABELED AS TO INTENDED USE. 4. ALL EXIT DOORS SHALL BE PROVIDED WITH PANIC HARDWARE, EXCEPT FRONT DOOR, SEE REMARKS. 5. THE OPERATING DEVICE ON ALL DOORS SHALL BE CAPABLE OF OPERATION WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, TIGHT PINCHING OR TWISTING OF THE WRIST TO OPERATE. THE INTERIOR HINGED DOOR SHALL BE 5.0 POUNDS (22.2 N) MAXIMUM PER FBCA SECTION 404.2.9 6. ALL INTERIOR DOORS TO BE LEVER TYPE WITH DOOR CLOSERS AND 1 /2" THRESHOLD. 7. LANDINGS SHALL BE PROVIDED AT EVERY REQUIRED EXIT IF ABOVE OR BELOW GRADE AND THEY SHALL BE A MINIMUM OF 36 INCHES IN WIDTH AND 44 INCHES LONG IN THE DIRECTION OF TRAVEL PER FBCB SECTION 101.1.6 VINYL FACE 9 20 GAUGE METAL STUD . ACOUSTICAL CEILING E @4'OC_/ t�0 STAINLESS STEEL FIM5H 5/5" GYPSUM WALL BOARP 3" AIR SPACE 3 5/8" METAL STUDS SELF -SERVE @ 6" O.C. AREA, STAINLESS STEEL FINISH SNEEZE GUARD--,, 1 GRANITE FINISH TOP, { — CERAMIC TILE_ 618" GYPSUM WALL BOA:R500 — 3 5/5" METAL STUDS 3/8" DIA THREADED RO[ ANCHORED TO TOP COI EXISTING STEEL BAR JOI I HOOD nl 4' --- - OPEN KITCH E 1211O i m CERAMIC TILT FINISHED WALL I GRIDDLE N N @ I G" O.C. 6" COVE BA5E STAINLESS STEEL FINISHED 6 COVE BASE"k? PINI HED F IOOR 5TAINLE55 STEEL LEG ECTON THR❑. OPEN KITCHEN AREA :LJALE:N.T.S. EXISTING ROOF TRUST 3 5/8" STEEL STUDS 3 5/8" STEEL STUDS CEIUNG \ J. 10 —0 A.F.F. BUILDING STANDARD CEIUNG PANEL &GRID FASTEN STUD RUNNER TO CEILING GRID @ 48" 0C. (MAX.) 3 548" STEEL STUDS @ �4' O.C. WITH RUNNER @ TOP & BOTTOM @ 72 GA, BARD EAPHUM SIDE QBASE (SEE ,,—FINISH SCHEDULE) : ((ggEE GALV. STEEL FLOOR TRACK ATTACHED i� FLOI RI SCHEDULE) @ FASTENERS @ 24' MAXIMUM SPACING _i WALL DETAILS <` 'v 1 SCALE:N.T.S. TOP OF WALL 4'-6' A.F.F. CORNER BEAD, TAPED AND SPACKLED 3 5/8" STEEL STUDS @ 4" O.C. WITH RUNNER @ TOP & BOTTOM @22 GA. 1 /2,' GyPzUM BOARD EACH SIDE BASE (SEE FINISH SCHEDULE) F OORWG SEE FINISH SCHEDULE) W2 WALL DETAILS SCALE:N.T.S. D `I-- #3 REBAR@36"O.C. 2" EMBED WITH EPDXY 6 MIL POLYTHL VAPOR BARRIER PER FBC 1901.1 COMPACTED FILL 12" LIFTS TESTED TO 95% COMPACTION CAP BETWEEN 18" TO 30" CONCRETE SLAB ON GRADE NEW 4" THICK CONCRETE SLAB MINIMUM OF 3000PSI 6 MILL VAPOR BARRIER ON 4" MIN. TERMITE TREATED COMPACTED FILL Iko X •X D X X .X SCALE:N.T.S. 18 min. (A) FRONT APPROACHES X I I PUSH SIDE l LOCKSETS WEATHERSTRIP(W) NO. TYPE MODEL FINISH BRAND 1 THRESHOLD 171A-36" AL PEMCO 2 THRESHOLD 171A-36" AL PEMCO 3 WEATHERSTRIP SET 303-AV AL PEMCO 4 DRIP CAP 346C-36" AL PEMCO 5 DOOR BOTTOM 216AV-36" AL PEMCO PANIC(C) NO. TYPE MODEL FINISH BRAND 1 SURF. MINT RODDED PANIC MANUR STNDRD US32D KAWNEER 2 PANIC -RIM DEVICE 98/98 RIM US32D VON DUPRIN PUSH/PULL(P) NO. DIRECTION TYPE MODEL FINISH BRAND 1 LEAF PULL 980P US32D HAGER 2 LEAF PUSH 1105 US32D HAGER 3 LEAF PULL MANUFACTURER'S STANDARD NOTE: 1. ALL INTERIOR DOOR HARDWARE TO BE SCHLAGE TYPE "AL -SERIES," REF. BUYER SPECIFICATIONS FOR FINISHES. 2. KEY ALL LOCKS TO MATCH ENTRANCE DOOR LOCKS. 3. IF NO EXISTING PANIC HARDWARE ON EXISTING EXTERIOR DOORS, USE C-1 FOR DOUBLE LEAF OPENINGS AND C-2 FOR SINGLE. PULL SIDE PULL SIDE 24 min. E X T � NOTE: x = 36 IN MINIMUM IF y = 60 IN NOTE: y = 54 IN MINIMUM IF THE DOOR x = 42 IN MINIMUM IF y = 54 IN. HAS A CLOSER. (B) HINGE SIDE APPROACHES (C) LATCH SIDE APPROACHES 5. PUSH SIDE PUSH SIDE >. 24 mr x =' r E NOTE: x = 12 IR IF THE OOR NOTE: y = IN IF DOOR HAS NOTE: y = 48 IN HAS BOTH A CLO R AN A LATCH. BOTH A LAT AN A CLOSER. CLOSER. PROVISIONS FOR BARRIER FREE DOORN SCALE: NTS DOOR HAS A o Q JpF-Q� c�owcwn>vi w W w U Z m 0 Q U J O Q C-) >-Qcnz�20 CD m o cn L` w ►"�too � J O M ¢ ww;z Z N U = "E252 0 zoaz�Q QQoC) aso �Zw�Q W O F_ �N�zz Q ��. 0 V2, 0 �P.• v:tc, 0 Q a) 6 ;�: •vJ O �� J: c� c) O. z � O J z I •c J 1 .• LLJ'•, b'•••.....• ' F �•• J Q 0 Q w c G w N J M � z 0 Q M W J z o v REVISION 1 1 2 3 i 4 5 6 7 I PROJECT TYPE: RENOVATION SCALE AS SHOWN ISSUED DATE: 03-08-2024 DRAWN BY: AYENG CHECKED BY: A. LI AN G SHEET A4 I t SERVICE COUNTER TOTAL LENGTH: 18'-9" ADA HEIGHT: 2'-10" TOTAL HEIGHT: 3'-6" 3RANITE COUNTER TOP - TOTAL WIDTH: 4'-0" OR 3/4 PLYWOOD W/ MATERIAL: 1 " THICK PLYWOOD W/ FRP COATING FORMICA FINISHED 1; PLYWOOD W/ FORMICA FINISHED II QQ I 3/4 PLYWOOD W/ . r, FORMICA FINISHED 6" HEIGHT TAINLESS STEEL LEG f -E f ---- MIN. 36" -/ FINISHED FLOOR - - SYP ' :7LS OF ACCESSIBILITY AND THEIR BACKGROUND SHALL HAVE A NOI -- ;LARE FINISH. SYMBOLS OF ACCESSIBILITY SHALL CONTRAST WIT FHEIR BACKGROUNDS, WITH EITHER A LIGHT SYMBOL ON A DAF BACKGROUND OR A DARK SYMBOL ON A LIGHT BA( ROUND. Z I WOMEN MEN T NOT IN • • •• PICTOGRAM • • •. •• S. • S S •. AREA Ml' I,,71NG HEIGHT: CHARACTERS SHALL BE 48 INCHES MINIMUM AN 50 INCHES MAXIMUM ABOVE THE ADJACENT FLOOR OR GR ..ND SURFACE, MEASURED FROM THE BASELINE OF THE CH - ACTERS. M,. -STING LOCATION: WHERE A TACTILE SIGN IS PROVIDED AT A DO THE SIGN SHALL BE ALONGSIDE THE DOOR ON THE LATCH SIF I� 9„ 230 6" MAX. 150 (A) ELEVATION 8" MIN. 205 N FIG.- 3062 TOE CLEARANCE 9" MIN. 230 430 - 635 (B) PLAN 11" MIN. I 635 280 (A) ELEVATION (B) PLAN FIG. 306.3 KNEE CLEARANCE NOTE: EACH DOOR TO AN EXIT SHALL HAVE A TACTILE SIGN, MOUNTING HEIGHT 48" MIN. AND 60" MAX. ABOVE ADJACENT FLOOR OR GROUND SURFACE. INCLUDING RAISED LETTERS AND BRAILLE, STATING: DUT BRAILLE SHALL BE MOUNTED 48" MIN. -60" MAX. AFF. TO THE BASELINE OF THE BRAILLE. PER ANSI -Al 17.1-2012 SECTION 703.4.5 ICC/ANSI SECTION 703.3.10 & SECTION 703.4.5 CEILING 8'-0" A.F.F. 4'-0" A.F.F. 1'-6" A.F.F. E 0 0 M �Epit1 KNEE & T( CLEARANCE �O4 30"X48" CLEAR FLOOR SPACE- - SERVICE COUNTER,/BAR FRONT APPROAC EXIT }" Exir sicN SWITCHES a a I Q RECEPTACLES FLOOR DEVICE MOUNTING HEIGHTS DETAIL N.T.S. NOTE: HANDICAP ACCESSIBLE SEATING 5% OF TOTAL SEATING CAPACITY TOTAL SEATING 160 X 5% =8 8 HANDICAP ACC. SEATS PROVIDED FAC 308.2.1 UNOBSTRUCTED FORWARD REACH 00 KAAV N N r (A) FAC 308.2.2 (B) OBSTRUCTED HIGH FORWARD REACH 255 (A) 255 - 610 FAC 308.3.2 MIN. CLEARANCE FOR SEATING AND TABLES UNOBSTRUCTED SIDE REACH OBSTRUCTED HIGH SIDE REACH FAC 309.3 OPERABLE PARTS SHALL BE PLANED WITHIN ONE OR MORE OF REACH RANGES SPECIFIED IN 308 255 FAC 308.3.1 0 N ^ w o Ld � Uj r 1 ~ z -CC LLJ w ¢ C) I-- Q WQ� Z C��Wcn>(n W W Lu W ¢ C WO • U �Q � V �wOm QF— Q J u? � �= LLJ W mzF--U M M mLLJ N O w cn ¢acn�Qw ¢ LAJ �-- w w � U z >- z F-5ELQc5z zr�44 V O Q" 00 Zooz�¢ ¢ ¢ � O cn Lo � O -CC = m Z Z O H L7N— 00 0 v u� ssslovill .♦'$ C> •'•. J 46 _< �U Q O: Z: J ��; •/'��0, J • / • J Q 0 Q wl I Q N J � H z Q M W � J z �> Z Q OC q Z w ►-a W Q-, U ME w C. �.7MN Na � REVISION 1 I 2 3 I 4 5 6 7 PROJECT TYPE: RENOVATION SCALE AS SHOWN ISSUED DATE: 03-08-2024 DRAWN BY: A.FENG CHECKED BY: A.LIANG SHEET A5 GENERAL ELECTRICAL NOTES: 1. ALL ELECTRICAL WORK SHALL BE DONE IN STRICT ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE EDITION 2020 2. WIRING SHALL BE INSTALLED IN METAL CONDUIT OR MC CABLE. WHERE SUBJECT TO PHYSICAL DAMAGE AND EXPOSE TO WEATHER, THE CONDUIT SHALL BE RIGID GALVANIZED. 3. ALL WIRES SHALL BE RATED FOR 600 VOLTS. MINIMUM CONDUCTOR SIZE SHALL BE AWG#12. COPPER WIRING UNLESS NOTED OTHERWISE. 4. PROVIDE GROUNDING IN ACCORDANCE WITH THE NEC. ALL BRANCH CIRCUITS SHALL CONTAIN EQUIPMENT GROUNDING CONDUCTOR. 5. ALL SWITCHES AND RECEPTACLES SHALL BE SPECIFICATION GRADE, IVORY COLOR. INSTALL 48" ABOVE FINISHED FLOOR AND OUTLETS AT 36" ABOVE FINISHED FLOOR. UNLESS NOTED OTHERWISE. 6. PROVIDE LIGHT FIXTURES PER THE FIXTURE SCHEDULE 7. PROVIDE ALL CIRCUIT BREAKER PER THE PANEL SCHEDULE. MULTI -POLE BREAKERS SHALL BE COMPLETE UNITS. 8. CONDUIT, ROOF AND WALL, PENETRATIONS SHALL BE SEALED AGAINST MOISTURE AND SHALL MAINTAIN THE REQUIRED FIRE RATING IN ACCORDANCE WITH UL SYSTEM 186. USE A UL APPROVED, FIRE RATED SEALANT SIMILAR TO DOW CORNING FIRE STOP 2000. 9. LIGHTNING PROTECTION AND BUILDING GROUNDING SYSTEM TO BE INSTALLED PER NEC, STATE AND LOCAL AMENDMENTS. ELECTRICAL SYMBOLS LEGEND MAY BE USED ON PRUCT NOTE - W ALL SYMBOLS SYMBOLS DESCRIP110M SYMBOLS DESCRIPM DUPLEX RECEPTACLE MID. +18• AFF ID TPANVORM - SUE AS NOTED 240 VOLT RECEPTACLE (HT. AS REQ.) PANEL - SIZE AS NXTTED QUADRUPLEX RECEPTACLE, MID. +16• F-FAN M- MOTOR COIMfIERfOP ff. RECEPTACLE +42• CKT. FKNIF M (B UmICATTS PANW i• DESX;#UTES f2R ff NUMBER WP�Gf � DUPLEX RECEPTACLE - N WECHER 4ee E)QT/D ERGDICY LX#IT W. BATTERY BACK-UP. PROOF EIt2,.OSUF E OR COVER, GROLND FAULT NTEI&M. DARGDO LOU W. BATTERY BACK-UP. SIW POLE swlr H. MID +470 REMOTE HEAD 12 DUN. S 101, M@ +47' 03 2X4 niIOI§SCEIT LOW F IXIM A DESIGNATES FIXTURE TYPE DUO NO. L11D +4r 15A NL FLUORESCEIT LIGHTING MIGHT LPIT O ,RIN= BOX. FLUSH IF POSSIBLE O RECESSED LIGHING FIXTURE B DESIGNATES FTXIURE TYPE DWMCr SWRCH W/ STARTER HOOD LOff DI9OMNL:Cr SMM NCAI'OESM LIGHT W/ 10OW BULB C DESIGNATES FOX TYPE OCCUPANCY SENSOR ® CEILING MOUNTED OUTLET ® ExisnNG ELECTRICAL nMRE KEY NOTE: 1. EXISTING AC SYSTEM NO CHANGE 2. EXISTING ELEC. RISER NO CHANGE. 3. EXISTING ELECTRICAL PANEL: A; C; NO CHANGE. - TO RECONNECT REPLACED BUFFET TABLE CIRCUIT TO EXISTING BUFFET TABLE CIRCUIT, CONTRACTOR SHALL RE -VERIFY EXACT ELECTRICAL SYSTEM ON THE JOB SITE. - TO RECONNECT REPLACED EXHAUST FAN AND MUA TO EXISTING CIRCUIT, CONTRACTOR SHALL RE -VERIFY EXACT ELECTRICAL SYSTEM ON THE JOB SITE, u r(& Q a <:3m l Fes) Wy W�W z C.7 m W N > vi F..� `� n � 6)Z¢3CmCL � Lo m-c O rr ll� o 0­4 �uj NV CD U5 OM cn LL.Q L)m 65o �A =NCDa--cz�W zwcnU (7 O zooz�Q �G¢^OV= Z0 00 pq F� ,-I W Z F�-f `t W Q 000 U — � 0- A a w o0 C) 0 •��§111111•••• . �.•• . cl- . P . ♦ • •. �4j �4;� Q c� ZC? :(D:w J 0 4 Q: z :U 0 0 zi O: Z:ul vQ� J 11 %••• 0 • J .� N �•,�b•'••.... .• . fit`••• ss Z c� J 0 CL CL Q Q 0 _J W c' cl- M o M ►-� Z CD Z o M 1.4 a 1.4 J a � 10-1 Q V � w W OO1a' �w FW W L'7MN REVISION 1 107/17/24 REVISION 2 1 3 1 4 1 5 1 6 1 7 I PROJECT TYPE: RENOVATION SCALE AS SHOWN ISSUED DATE: 03-08-2024 DRAWN BY: A.FENG CHECKED BY: A. LI AN G SHEET LIGHTING NOTES: 1. PROVIDE A MIN. 50 FOOT— CANDLES OF LIGHT ON ALL WORKING SURFACES IN THE FOOD PREPARATION AREAS, EQUIPMENT AND UTENSIL WASHING AREAS, AT HAND WASHING LAVATORIES, AND IN TOILET ROOMS. 2. PROVIDE A MIN. 20 FOOT— CANDLES OF LIGHT AT A DISTANCE OF 30 INCHES ABOVE THE FLOOR IN WALK—IN COOLERS AND FREEZERS, DRY STORAGE AREAS, AND IN ALL OTHER AREAS. 3. ALL LIGHTING FIXTURES AND LIGHT BULBS LOCATED WITHIN FOOD PREPARATION AND STORAGE AREAS SHALL BE SHIELD OR SHATTERPROOF. 4. ALL THE EMERGENCY LIGHTS MUST BE CONNECTED TO NO SWITCHED LIGHTING CIRCUIT. 5. THE CONSTRUCTION DOCUMENTS SHALL SPECIFY THAT DOCUMENTS CERTIFYING THAT THE INSTALLED LIGHTING CONTROLS MEET DOCUMENTED PERFORMANCE CRITERIA OF SECTION C405 ARE TO PROVIDED TO THE BUILDING OWNER WITHIN 90 DAYS FROM THE DATE OF RECEIPT OF THE CERTIFICATED OF OCCUPANCY. 6. CONSTRUCTION DOCUMENTS SHALL REQUIRE THAT WITHIN 30 DAYS AFTER THE DATE OF SYSTEM ACCEPTANCE, RECORD DRAWINGS OF THE ACTUAL INSTALLATION SHALL BE PROVIDED TO THE BUILDING OWNER, INCLUDING: — A SINGLE —LINE DIAGRAM OF THE BUILDING ELECTRICAL DISTRIBUTION SYSTEM AND — FLOOR PLANS INDICATING LOCATION AND AREA SERVED FOR ALL DISTRIBUTION. PER FBCE 405.6.4.1 LIGHT FIXTURE SCHEDULE QUAN TITY DSCRIPTION STATUS WATT SYMBOL 2X4 LED TROFFER LIGHT, 120V, 18 8 WATT/LAMP. 3500K RELOCATED 54 2X2 LED TROFFER LIGHT, 120V, 18 WATT/LAMP. 3500K NOT IN USE 36 62 6" RECESSED LED DOWNLIGHT 3500K. NEW 18 0 LITHONIA TYPE: 65BEMW OR EQUAL HANGING LED LIGHT 3500K. NOT IN USE 18 TRACK LIGHT NOT IN USE 36 SCONCE, DESIGNHOUSE: 573154 OR EQUAL NOT IN USE 18 Z EXTERIOR BACK LIGHT W/ BATTERY NOT IN USE 60 BACKUP 4 DAY- BRITE MCPHILBEN CXXL3RW EXISTING/NEW 5 EMERGENCY EXIT LIGHT 7 HUBBELL LIGHTING, CU2SQB EMERGENCY EXISTING/NEW 2 BATTERY LIGHT Ll(__�--ITING PLAN ro W �- z +�-'n W J01--¢m � W cOz�N�W 3 m w U' �NW� M M W �NO��U Ed < ,O] t� M U Q WIawLu = v'c�—QC=D z w`� A 'c m Zo�Z�a LZ Q (� O CZ_')=�ZZ A 44 44 0000 d- 4- Lo ••••1. 2 "•4"r .•W •,� G •., CL �. • ... 0 J � Z % c� U O: 2: • i Q Z '4' J (('_�� Q •..47 NF 44 Id Q Q 0 J W Of � ' � M z O M U ZE ww Z O Z a � a Z Z P U O V \ F cr_ W El REVISION 1 107/17/24 REVISION 2 3 4 I 5 6 7 i PROJECT TYPE: RENOVATION SCALE AS SHOWN ISSUED DATE: 03-08-2024 DRAWN BY: A. FEN G CHECKED BY: A, LI AN G SHEET ------------------------------------------------------� r-----------------------------� I I I I I I I I I I I I I I I L J L_ J L_ J L_ r-_-� T T T T------I--� r� ,--�---, I I EXISTING TRANSFORMER r-------, r-1---1___L__J__________� EXISTING 24 HOURS TIME I A I I B I I I SWITCH WITH MANUAL OVERRIDE ( C I Mi j r - - - - - - - - - - - - - - - - 1 I 1120/208 I I 120/208 1 L J FOR GENERAL LIGHTING 1120/208 EXISTING METER CENTER I I I t I I � I I 1 3t,4W I I 1 t,3W I r -I 1 1 0,3w I I I EXISTING 1 L. _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ - I 200A I I 200A I I I EXISTING 24 HOURS TIME I 200A I I I I 1 I MAIN 1 1 1 OK A.I.C. I 110K A.I.C. I L J SWITCH FOR TENANT SIGN 110K A.I.C. L T J I I I SERVICE I I M.C.B. I I M.L.O. I I M.L.O. t l I I I I I 120/208 I L____J L____J L____J I I I I 3�,4W 1 I 400A I I I 1 I L-T-T--� I I I I I 1 1 1 L - - - -----� 1 I I I 1 I 1 1 L- - - - - - - - - J L--------- 1-------------- 1 i ALL ELECTRICAL EQUIPMENT I I EXISTING INCOMING POWER IINDICATED BY A DASHED LINE IS', 1 j--------------------J ,_____EXISTING TO REMAIN 1 EXISTING POWER RISER DIAGRAM I EXISTING SERVICE GROUND, CONTRACTOR SHALL VERIFY SC&EAT,S, IN ACCORDANCE WITH NFC. B0 5.90 A (OONNECTM) EXISTING PANEL B 1 O 120/240 VOLT FED BY: 200 AMP BUS 61 AM M.L.O. BREAKERINTERRUPTRATING: IXISTING A.I.C. 69 AW9 NOTES: kV WA CKT CKT WA WA WIRE COND A Bo C/B NO. NO. C/B A o B 0 LOAD DESCRIPTION SIZE SIZE OV80 ) TOTAL 14.70 WA (OONNECTED) 16. WA (NEC 220) RE ZE LOAD DESCRIPTION 1/2" 2#12 f�Pf-CPTG-1 1.00 1P-20 /ti 1 2 / 1FL20 1.00 IX LGT-KITCI-EN IX 112" 2#12 RECPT CEILING-2 1.00 1P 20 ,� 3 4 .� 1P-20 0.80 REC 7rION 2#12 11T IX EX STORAGE & RESTROOM 1•� 1P-20 r� 5 6 /"� 1PL20 0.80 EXRECPTSHOW WINDOW EX 112" 2#12 RECPT-CEILIM 1.00 1P-20 /ti 7 8 /1 11 0.80 IXLGT-WALK-IN UNITS IX IX IX LGT HALLWAY 0.80 1P-20 9 10 n 1P-20 1.00 RECPT-CEILING-4 2#12 1/2" IX IX RBCPt 0.50 1 R20 n 11 12 - 1/2" 2#12 LGT DN M AREA 1.00 1P-20 /� 13 14 /� 1 P•20 1.00 IX LGT IXTERK3R IX 1/2" 2#12 LGT DN M AREA 1.00 1P--20 15 16 - - n 17 18 - EX IX EuER AiNC:Y LGT 0.80 1P-20 /ti 19 20,-� - - 21 22 /r - - n 23 24 n - EX IX STORE SIGN 1.20 1 P 20 .� 25 26 ,-N - - 27 - - 29 30 /r - - n 31 32 / - - 33 34 / - - - n 35 36 ,, • - - n 37 38 /�• - - 39 40 - / - 41 42 n - I / - n 43 44 / - 45 46 ,-O�-*% - ! 50 52/� - ! F.T.L. CONNECTED LOAD: - - - TOTAL FEEDER CALCS PER NEC ARTICLE 220 LIGHT RECEPT KITCHEN COUNT 0 REFRIG 10 KVA@100% + 50% REMAINING % 125% LOAD 7.0 % LOAD kVA CONTIN 125% 2.5 kVA kVA NON-CONTIN 100% 0.0 kVA kVA HVAC 100% 0.0 kVA kVA TOTAL FEEDER LOAD 16.6 kVA ** 6.3 100% 0.8 100% 0.0 r l V r Z I+. a � W Q W V CDmWN�W LLi WZW U Z m O U cm W I-1 - 'IT N F., N W� Z >-a-5 o OM LLJ m ��` Nc)mLL- � 00 M cn Q En W Q W Q N H W W Z F' I,.{� O0 Ca o C) Q¢��-<0 00 LLJ = c/) a AC`�a:w00 00. V=a w Q • .� C Z; LLJ v0� Q N �•• fib•'•••.... .••.� ••. z 0 0 a 0 J W CIA ,d. W M = � M Q h-� = z 0 � �Z� J Z � A v� �a Fw W UcnN W REVISION 1 107/17/24 REVISION 2 1 3 1 4 1 5 1 6 1 7 I PROJECT TYPE: RENOVATION SCALE AS SHOWN ISSUED DATE: 03-08-2024 DRAWN BY: A. FEN G CHECKED BY: A. LI AN G SHEET EXISTING 12X10 H\ --.0 PLAN :4A 350 100 T EXISTING EXHAUST DUCT THROUGH THE WALL TO RESTROOM, IN 80 METAL DUCT(TYP.) 8"Pd�• � __ IC1OFOM �a , EX. CFM 6"Sp � s 100 E # CFM 60 60 E - A F l R jji _ .. r7.. E -.-••-�- -°'-.ter^ram _-,� EXISTING 14X14 EXISTING 1OX8 z EXISTING RETURN 250 cFM AIR EXCHANGE s� GRIDDLE(TYP.) OD EXISTING AHU# 1-4 EXISTING 18X16 5 TON 2000 CFM(EACH) to0 X CO c� z L xx EXISTING 16X14 AIR EXCHANGE GI 1090 DESIGN NOTES: DESIGN AND INSTALLATION TO W/FBC 2023 8TH EDITION -WIND LOADING:140 MPH, -RISK CATEGORY: II -IMPORTANCE FACTOR: 1=1.0 -EXPOSURE: "B" -WIND LOADING: ROOF LIVE LOAD: 20 PSF VENTILATION CALCULATIONS (BASED ON FBCM 8TH EDITION TABLE 403.3.1.1) OCCUPANCY CATEGORY SQ FT SF/P P CFM/P CFM/SF CFM (P) CFM (AREA) TOTAL CFM NOTES DINING AREA 1997 160 7.5 0.18 1200 359 1559 KITCHEN&SERVICE AREA 1451 100 145 7.5 0.18 1088 261 1349 BUSINESS 1007 50 50 5 0.06 252 60 312 KITCHEN (COOKING) 140 20 3 -7.5 -0.12 -21 -17 -38 TOILET ROOMS(PUBLIC) 319 5 -50 0 -250 0 -250 TOTAL CFM REQUIRED: 2933 AC UNIT OUTSIDE AIR CFM PROVIDED 2000 MUA CFM PROVIDED 8400 TOTAL CFM PROVIDED 10400 NOTES: FOR ALL CATEGORIES: OCCUPANCY CATEGORY AND DENSITY FROM TABLE 403.3.1.1 FBCM 8TH VENTILATION GENERAL NOTES: 1. VENTILATORS & DUCT SHALL BE DESIGNED, CONSTRUCTED AND INSTALLED IN ACCORDANCE WITH SECTION 506.3.1 THROUGH 506.3.12 OF (2023 FBC-MECHANICAL 8TH EDITION), (NFPA 96 2017 EDITION CHAPTER 6 THROUGH CHAPTER 8) 2. EXHAUST HOOD SHALL BE DESIGNED, CONSTRUCTED AND INSTALLED IN ACCORDANCE WITH 2O23 FBC-MECHANICAL, 8TH EDITION SECTION 507.2.5 THROUGH 507.2.9. AND NFPA 96 2017 EDITION CHAPTER 5. 3. TYPE I HOODS SHALL CONSTRUCTED OF STEEL NOT LESS THAN 0.043 INCH (1.09MM) (NO. 18 MSG) IN THICKNESS, OR STAINLESS STEEL NOT LESS THAN 0.037 INCH (0.94MM) (NO. 20 MSG) IN THICKNESS (5.1.1 NFPA 96 2017 EDITION). 4. EXHAUST FAN HOUSINGS SERVING A TYPE I HOODS SHALL BE CONSTRUCTED OF STEEL (2023 FBC-MECHANICAL SECTION 506.5) AND (8.1.4 NFPA 96 2017). EXHAUST FAN MOTORS SHALL BE LOCATED OUTSIDE OF THE EXHAUST AIRSTREAM (2023 FBC-MECHANICAL SECTION 506.5.1.1) AND (7.8.1 NFPA 96 2017 EDITION). 5. - GREASE DUCTS SERVING TYPE I HOODS SHALL BE CONSTRUCTED OF STEEL HAVING A MINIMUM THICKNESS OF 0.0575 INCH (1.463 MM) (NO. 16 GAGE) OR STAINLESS STEEL NOT LESS THAN 0.0450 INCH (1.14 MM) (NO. 18 GAGE) IN THICKNESS. (2023 FBC-MECHANICAL SECTION 506.3.1.1) AND (7.5.1 NFPA 96 2017 EDITION) - ALL SEAMS, JOINTS, AND PENETRATION OF GREASE DUCTS SHALL BE MADE WITH A CONTINUOUS LIQUID -TIGHT WELD OR BRAZE MADE ON THE EXTERNAL SURFACE OF THE DUCT SYSTEM (PER 2023 FBC-MECHANICAL, SECTION 506.3.2) AND (7.5.2.1 NFPA 96 2017 EDITION) - DUCT JOINTS SHALL BE BUTT JOINTS OR OVERLAPPING DUCT JOINTS OF EITHER THE TELESCOPING OR BELL TYPE. (PER 2023 FBC-MECHANICAL SECTION 506.3.2.1.) AND (7.5.5 NFPA 96 2017 EDITION) - DUCT -TO -HOOD JOINTS PER (2023 FBC-MECHANICAL SECTION 506.3.2.2) AND (7.5.2.2 NFPA 96 2017 EDITION). - DUCT -TO -EXHAUST FAN CONNECTIONS PER (2023 FBC-MECHANICAL SECTION 506.3.2.3) AND (7.5.1 NFPA 96 2017 EDITION) - VIBRATION ISOLATION CONNECTOR FOR CONNECTING A DUCT TO A FAN SHALL BE (2023 FBC-MECHANICAL SECTION 506.3.2.4.) - GREASE DUCT SUPPORTS (2023 FBC-MECHANICAL SECTION 506.3.3) 6. GREASE DUCT SYSTEMS SERVING A TYPE I HOOD SHALL HAVE A CLEARANCE TO COMBUSTIBLE CONSTRUCTION OF NOT LESS THAN 18 INCHES (457 MM) (2023 FBC-MECHANICAL SECTION 506.3.6) AND (SECTION 13-4.1 OF NFPA1, THE FIRE CODE 2023 EDITION) 7. THE FIRE EXTINGUISHER SYSTEM MUST BE INSTALLED BY A LOCAL LICENSED COMPANY, SEPARATE PLAN MUST BE SUBMITTED TO LOCAL FIRE DEPT. FOR APPROVAL. (SECTION 13-2.1 THROUGH 13-3.9 OF NFPA1, THE 2023 FIRE CODE) AND (SECTION 10.1 THROUGH 10.2.6 OF NFPA 96 2017 EDITION) 8. ALL ELECTRICAL WORK MUST BE DONE BY LOCAL LICENSED ELECTRICIAN. KEY NOTE: 1. GREASE HOOD FIRE SUPPRESSION CONTRACTOR SHALL SUBMIT SHOP DRAWING FOR APPROVAL AND PERMIT. 2. EXHAUST DUCT SHALL BE 18" AWAY FROM ANY COMBUSTIBLE MATERIAL 3. ACTIVATION OF FIRE SUPPRESSION SYSTEM SHUTS OFF ALL FUEL SOURCES, GAS AND ELECTRICITY UNDER THE HOOD INCLUDING SUPPLY AIR, LEAVES EXHAUST FAN RUNNING. 4. AN AUTOMATIC SUPPRESSION SYSTEM PROVIDING MANUAL ACTIVATION SHALL BE INSTALLED IN THE KITCHEN HOOD SYSTEM. 5. CONTRACTOR TO BALANCE THE AIR PER FBC 2023, SEC 601.4. PRESSURE DIFF. ACROSS CLOSED DOORS WHERE RETURNS ARE CENTRALLY LOCATED SHALL BE LIMITED TO 0.01 INCH WC OR LESS. 6. CONTRACTOR SHALL PROVIDED TEST AND BALANCE REPORT BEFORE FINAL MECHANICAL INSPECTION PER FECC 2023 SEC C408.2.2 NEW EXHAUST FAN & M ID SERVICE MFR. & MODEL TYPE LOCATION # KEF-1.2,3 KITCHEN ECON AIRE OR ROOF EQUAL KEF-4 KITCHEN ECON AIRE OR ROOF EQUAL FAN NOTES: 1. ALL FANS TO BE PROVIDED AND INSTALLED BY MECI 2. PROVIDE FAN WITH CEILING TO INLINE CONVERSION F 3. PROVIDE BACK -DRAFT DAMPER. 4. PROVIDE WEATHERHOOD 5. FAN SHALL OPERATE WITH LIGHT. AIR BALANCE SUMMARY ID LOCATION SUPPLY RETURN OUTSIDE MAKE UP EXHAUST PRESSURE EX. AHU-1 2000 1500 500 500 EX. AHU-2 2000 1500 500 EX. AHU-3 2000 1500 500 EX. AHU-4 2000 1500 500 NEW KEF-4 -1500 KEF-1 -2700 - 200 KEF-2 -2700 DEF-1 -500 MUA-1 4000 KEF-3 -2700 MUA-2 4400 EX. TEF-1 RESTROOM -250 -250 2000 B400 -10350 50 V Q Cr Q _JMHQCr � W moV _ W (J Z C) O (►, M M m LL J U5 � w �0LwF W 0O dk I-1l <\ M Q N Q Q N E2 LE Z W '� A `,�° 00 Zoo=V) Qa��JO �] Q P� W O O � w 0 0 Ln Ul cl- 4b • • i CD �; Z 1 V � � • ; J • o w 'q O• CD . J• z U O: Z: � •i 0 z •• �•O� J Q J • LLJ i !� cn .,� R 41 ••. J 0 0-1 cl- CL Q W Q 0 J W AMU o 1 l cn z o M M-I Z�J ll� H Z A U � LIMN �_ ❑ REVISION 1 1 2 3 4 5 6 7 PROJECT TYPE: RENOVATION SCALE AS SHOWN ISSUED DATE: 03-08-2024 DRAWN BY: A.FENG CHECKED BY: A.LIANG SHEET m I - - - , - -7 --i i . _ I j , : S -I I , -, , � r - 4 ; I --- - - I a r f , : _ I i _ - : : _ I� - i a I- I- : J f h 1 F- , : : T L - - - - +- EXISTING MUA-1 -- --, : : : i _.. _{ _ : '1 , . I : 1 RCI )F TOP EQUIPMENT PLAN SCA__; 1/4"=1'-0" EXISTING TEF-1 ,o REPLACED REPLACED DEF-1 KEF-1 NEW — KEF-4 I 1 I REPLACED \- �� J/ -I KEF-2 NEW KEF-3 NEW MUA-2 MIN. 120" CLEARANCE W/INTAKE AIR(TYP.) MIN. 120" AN -am MAKE UP AIR - DUCT MUA U A/P 4 3" AIR ® 16" O.C. 25 GA STAINLESS STEEL SHEET ADD ONE LAYER OF FIREGUARD ON EXISTING FIRE RATED WALL FROM FLOOR TO CEILING Iz Min. O° Floor HOOD SYSTEM ELEVATION SCALE: N.T.S. KEF MIN. 120" NEW NEW REPLACED REPLACED MUA-2 KEF 3 DISCHARGE KEF#2 KEF#1 �4 OF FAN(TYP.) Existing Roof i.\ NEW 20"X20" MUA DUCT CESS PANELS AT J 16X16 GREASE DUCT 16X16 GREASE DUCT W/ FIRE WRAP Q ALL CHANGE OF W/ FIRE WRAP CONFORM DIRECTION(TYP) TO NFPA 96 Np A/p ERE 16X16 GREASE DUCT W/ FIRE WRAP CEILING 14"0 DUCT Q N 9'-0" 9'-0" 9'-0" MIN. " o"01 M .6" 7-40M WOK F=9 � � � 00 z BACK SLASH 00 oo me WOK STOVE SIDE I FRONT Y-6" 15-1" 1'-4" 1'-4" V-4", I 3'-2" 1 KEF#4 z 4 ACCESS PANELS AT ALL CHANGE OF DIRECTION(TYP) CONFORM TO NFPA 96 C 12`X12" GREASE DUC W/FIRE W Q DISCHARGE OF FAN HOOD 6'-O" MI 6" MI . 6" GRIDDLE 0 0 I FRONT 5'-0" HOOD SYSTEM ELEVATION SCALE: N.T.S. Existing CEILING Floor REPLACED MUA-1_ KEF#4 4 CEILING SIDE 12"X12" GREASE DUCT W/ FIRE WRAP Q C'4 C a x Gas Griddle & o4 Char -Broiler al j 1 (non-charcli� o Stainless '� Steel Tat INSULATED FLEXIBLE DUCT INSTALL FLEX -DUCT AS STRAIGHT AS POSSIBLE. NO BEND OVER 90', NO CRUSHING OF FLEX -DI 1" HANGER STRAPS MAX. 10' SPACING SUPPLY DUCT � I MANUAL VOLUME DAMPER METAL COLLAR WITH BAND CLAMP, SCREWED (3) PLACES AND TAPE TYPICAL BOTH ENDS OF FLEX DUCT. EXISTING 20"X18" MUA DUCT CEILING FLOOR DISCHARGE OF FAN z 3" AIR SPACE Sneeze Guard -Granite 5/8" Cement Board -5/8" GYP. BD. 3/8" Ceramic Tile 3 5/8" metal studs MINIMUMRADIUS DIAMETER OR PROVIDE AN AIR STRAIGHTENING GRID. INSULATION BOOT. DIFFUSER SEE PLANS FOR TYPE DIFFUSER TAKEOFF DETAIL SCALE: N.T.S. W p r z Wpw Q �. 1�1 W Z C.7pWN>(N h--1 CD Q=pmO W l� _j F- U L> J< p p U U- 1 kr)N w>-z�zp m��MLi O �t O W M M O W pNl_ fy_C� m LLJ LLj Q—JpW�W 00 r- U Q NHW WZ'r W o noCDV) 00 poJo p Q (J� O O 0 NLd Z S2 Cr M En rn 0 L0 AMP 4 -4:10 0) A:-. i —j 6 :(D:w �, :U r •� O O: Z: --j LLJ V) J 0 CL w t- 0 _J W ZZ J ' M Z o Q M W v a Z o ~ a o w~ w o� �I �10 REVISION 1 1 2 3 1 4 I 5 1 6 7 1 PROJECT TYPE: RENOVATION SCALE AS SHOWN ISSUED DATE: 03-08-2024 DRAWN BY: A.FENG CHECKED BY: A,LIANG SHEET NGN ORED TO 14ED G�E ROD RpN ��>< 114 HOOD ISOMETRIC VIEW SCALE:N.T.S. EXISTING ROOF SYSTEM n G ANGLE �NGIN SEA Pl,fi1'E G ANGLE �AGN5TEE NAN PEP 1' NOOD A P OBI, 1 5" X 1. 5" U CHANEL TO TOP CORD OF ROOF JOISTS E:iTSVIS SUSPENE /8" DIA THREADED ROD i :::LING SYSTEM CLAM TO TO TOP CHORD OF EXISTING ROOF JOIST TYP. .winless steel sheet-0 1 n : 3" gyp. wall board 16 GA STAINLESS STEEL -cn floor to ceiling — HOOP CHANNEL CLIP FULL B WELDED TO HOOD TYP. ;ECTION 'zutxrs. O DETAIL 3/8" DIA. ALL THREAD ROD CONNECTED TO ROOF JOIST THROUGH ANOTHER HANGING ANGLE 1.5" X 1.5' "U" CHANNEL NUT FENDER WASHER 3/8' DIA THREADED ROD TO KINDORF CHANNEL STEEL HANGING ANGLE EAVY DUTY NUT AND ONE ABOVE AND ONE 'MG ANGLE ROD, NUTS, AND WASHERS TO BE SUPPLIED BY INSTALLING CONTRACTOR HANGING ANGLE IS PRE -PUNCHED AT FACTORY (: ) B PSP HANGING ANGLE 3/8" DIA. ALL THREAD ROD CONNECTED TO ROOF JOIST THROUGH ANOTHER HANGING ANGLE STEEL HANGING ANGLE 3/8" DIA. HEAVY DUTY NUT AND WASHER - ONE ABOVE AND ONE BELOW HANGING ANGLE ROD, NUTS, AND WASHERS TO BE SUPPLIED BY INSTALLING CONTRACTOR HANGING ANGLE IS PRE -PUNCHED AT FACTORY c CORNER HANGING ANGLE FLASHING RTU BASE RAIL 3/8" STAINLESS STEEL LAG a Z SCREW THRU CURB CID AND RTU BASE RAIL ROOF CURB a T 3/8" STAINLESS STEEL LAG STRUICNRAL SCREW THRU CURB JOIST ROOF-\ AND IRON BELOW ROOF FAN DISCONNECT, FACTORY WIRED TO MOTOR. «� ExTr:NSIaN GALV CURB k�FRLIIWFLEr. CMW THIS TYPICAL ASSEMBLY SHALL OCCUR ON ALL FOUR SIDES. MAX SPACING ON EACH SIDE SHALL BE 3'-0". MIN 2 ASSEMBLIES PER SIDE. MIN. 1500' F GASKET ALL AROUND ANGLE BENDS A -A 12"�• � EXHAUST DUCT A A L-41 ACCESS DOOR BOLTS ON 7" MAXIMUM CENTER NOTE: - ACCESS PANEL DOORS ARE CONSTRUCTED OF THE 16 GAUGE CARBON STEEL - GASKET IS RATED AT 1500 DEGREES F AND PANEL IS LIQUID -TIGHT - FASTENERS USED TO SECURE THE DOOR TO THE DUCT, DO NOT PENETRATE THE DUCT WALL EXHAUST scur:x.rs. DUCT CLEAN OUT DOOR DETAIL 71» MOM t •+�_` *1111A AGENT SYSTEM CONTROL A[rrr . WITH AGENT TANK ENCLOSED FireMaster FastWrap XL Commercial Kitchen Grease Duct Enclosure System Air Ventilation Duct Enclosure System 1 or 2 Hour Shaft Alternative / Zero Clearance to Combustibles Butt Joint / Overlap Butt Joint / Collar Option 3' (75) Overlap / 3" (75) Overlap Required for ULC Grease Duct Systems TWO LAYER INSTALLATION OPTIONS Telescope Wrap Option Butt Joint Option Checkerboard Wrap Option SINGLE LAYER OR OUTSIDE LAYER INSTALLATION OPTIONS System Details Tb. tdmy mFB.n•."rdW.V .-i. Mn Wd m tl. m.Wvtur WWM.n. FMXLM-3 (MANUAL PULL STATION U ro . UjoW rQ a =3o�QL�� Z C70Wcuni Wyy Z¢=�m0 U �LLJ O d• o LLJ }QNZ�O w °D��v w�= OM M L-im o (n (=) p CL z w A '° C7 0 00 ZoE3Z�Q aQW=VCO I--d Cc ) W 0 � F Z 00 Q O� 0 . #4 �,O' CZDzcDo .•L) .. :�•':•PZ�:•G�',.... i?O.i Z LLJ o z -Z 4 •�• Lj 0 V•' b•••• ••O ire U 0 0- lZ Q 0 w a dN' ' Q M o F= M Q w o J � W W Q� pew �O Fp w CL L`7MN= 4 REVISION I 1 2 3 1 4 5 6 7 I PROJECT TYPE: RENOVATION SCALE AS SHOWN ISSUED DATE: 03-08-2024 DRAWN BY: A. FEN G CHECKED BY: A. LI AN G SHEET t - _ Q 2 _. 2' S F.D. I :! 3 r`,3 '{ EXISTIN ,'� � , F IJ.3. 3. 4 ;!w q �3 : - _ t: � 3 a t i .,_ _ ..._. _ .. -. _ _ ...... _ __ _ ;° EXISTING; HAND s SINK 3.,. 4 s. 4 us ul : ®TINf. H.D. 24(1`7 , i : ti w I TO EXISTING 4" SANITARY LINE, ' CONTRACTOR SHALL RE -VERIFY EXACT LOCATION AND SIZE ON THE JOB SITE a - A U t , F' I S I � 1 ! i I i __ SA ITARY P LAN EXISTING H.D. TO EXISTING 3" GREASE LINE SIZING FORMULA FOR RESTAURANTS USING FAC 64E-6.013(7) D1 & D2 VOLUME BASED ON SEATS: PUMP OUT FREQUENCY = 60 DAYS EFFECTIVE CAPACITY OF GREASE= S X GF X HR/12 X RF WHERE: S= # OF SEATS = 160 HR= 10 HOURS PER DAY GS= 25 GALLONS PER SEAT RF= 0.75 EFFECTIVE CAPACITY OF GREASE=160 X (10/ 12) X 25 X 0.75 =2500 GALLONS PROVIDED CAPACITY OF GREASE=1 X2500 =2500 GALLONS , .1. 11 _ f k ---------- ILI= Siti.,�� �.i 7 TO CONNECT TO TO CONNECT TO EXISTING 3" GREASE EXISTING 4" GREASE LINE, CONTRACTOR € LINE, CONTRACTOR Y SHALL RE -VERIFY a -- SHALL RE -VERIFY - EXACT LOCATION AND - EXACT LOCATION AND SIZE ON THE JOB - ? SIZE ON THE JOB _ SITE. 3. - SITE. EXISTING 4" GREASE LINE,CONTRACTOR THD . ` SHALL RE -VERIFY EXACT LOCATION AND 3' - - SIZE ON THE JOB SITE $ 2' EXISTING 3" G.W. EXISTING 3' G.W. EXISTING 4" G.W. J EXISTM 4" G.W. : e i yr ! TO CONNECT TO �EX 3w EXISTING 4" GREASE F" 3 s p--" I IAIC tin K IT0 A r T n 0 IAkI 0 m �/ mz I I I I Z tv -I Cr 0O I I X 0 Mo I I 0r L___J TO EXISTING 4" GREASE LINE PLUMBING SYMBOL SCHEDULE SANITARY WASTE LINE ------.- - ...... - - HOT WATER SUPPLY LINE ....... --............... COLD WATER SUPPLY LINE F.D. FLOOR DRAIN Q F.C.O. FLOOR/WALL CLEAN -OUT W.C.O. F.S. FLOOR SINK OH.D. HUB DRAIN ALL PLUMBING FIXTURES SELECTED BY OWNER SUBMIT CAT CUTS FOR APPROVAL (TO OWNER) WASTE PLUMBING NOTES 1. CONNECT NEW WASTE LINE TO EXISTING WASTE LINE BELOW FLOOR. CUT EXISTING FLOOR TO INSTALL, & PATCH FLOOR TO MATCH EXISTING CONSTRUCTION. 2. EACH WELL OF A MULTIPLE COMPARTMENT SINK SHALL DISCHARGE INDEPENDENTLY TO A WASTE RECEPTOR. 3. TO INSULATE DRAINS AT PUBLIC LAVATORIES. PER ACCESSIBILITY 606.5 NEW PLUMBING FIXTURE SCHEDULE ALL EQUIPMENT ARE TO BE INDIRECTLY DRAINED EXCEPT HAND SINKS, LAVATORY, MOP SINK FIXTURE MANUFACTURE TYPE MODEL DESCRIPTION PIPE SIZE REMARK TRAP WASTE VENT C.W. H.W. W.C. AMER STAND CAD 17"H EL 16/PA 3042.109 4086.800 P.A. FLUSH TANK 1.69 GPF 3" 2" 1 /2" 17" HIGH ELONGATE IGHT BOW HAND FLUSH FLUSH LAV. AMER STAND LUCERNE 355.012 METERING FAUCET T&S B-0712 OR EQUAL 1-1/4" 2" 2" 1 /2" 1 /2" MTG. RIM 34" AFF. HOT WATER SUPPLIED TO LAVANTROY FIXTURES SHALL BETWEEN 85`F TO 109F HAND SINK REGENCY HAND SINK 600HS12SP FAUCET & DRAIN INCL. 1-1/4" 2" 2" 1/2" 1/2" 3-COMP SINK REGENCY 3-COMP SINK 60OS318242G 1-1/2" 3" 2" 3/4" 3/4" 2-COMP SINK REGENCY 2-COMP SINK 60OS218242G 1-1/2" 3" 2" 1 /2" 1 /2" DISH WASHER JACKSON DOOR TYPE CONSERVER XL DRAIN 2" 3" 2" 1 /2" 1 /2" C.O. J.RSMITH CLEAN OUT 4710-U 3" 2" F.D. J.RSMITH FLOOR DRAIN FD2370 1-1/4" 3" 2" F.S. ZURN FLOOR SINK FD2370 3" 2" J Z r ¢ W "�N�W � w¢ 2)mZ m O W�O¢ U m�(� O d O W C� Wr OM M m otnC) �w 00 d' V) ¢JU)LWI O Qp C) — GU-jp 0 U ¢ (/) Z Qn O N Z O n ��=�Z� AL`7awo M ,�4 d- w • .• .j . CD ''• �2'; �P'' Q •.Z O �• i� • (D J w :U O: Z: __j Ld cn z ••...��..•••'* J Q 0 w cl- 0 _J W d ' M o M z o M F�+-1 z '-' a•, z O V a C� M N REVISION 1 1 2 1 3 1 4 5 1 6 1 7 I PROJECT TYPE: RENOVATION SCALE AS SHOWN ISSUED DATE: 03-08-2024 DRAWN BY: A.FENG CHECKED BY: A.LIANG SHEET p 1 W/`---ER SUPPLY sck.:=: 1/4 11=1 $—on PLAN 3 CU N — 6) 1/2' C.W. —9 1/2' H.W. it II, 1/2' H.W. C 1/2' C.W. 3 V H.W. 3/4', H.W. - - --- 3/4' C.W. 1' C.W. n -01/2' C.W. —0 1/2' H.W. --9 3/4' C.W. 3/4' H.W. -03/4' C.W. 3/4' H.W. -0 3/4' C.W. 3/4' H.W. CONNECTED TO EXISTING 1" COLD WATER SUPPLY LINE. CONTRACTOR SHALL RE -VERIFY EXACT LOCATION AND SIZE ON THE JOB SITE WATER PLUMBING NOTES 1. CONNECT NEW HW AND CW SUPPLIES TO EXISTING PIPING ABOVE CEILING. 2. PROVIDE INDIVIDUAL BACKFLOW PROTECTION FOR ALL WATER OUTLETS CONNECTIONG DIRECTLY TO ANY MIXING, BREWING, DISPENSING APPLIANCE, SODA, FILTER, ICE MAKER, DEVICE OR APPARATUS AS REQUIRED BY FLORIDA BUILDING CODE PLUMBING 608.3 AND 608.15 3. PLUMBING MATERIALS: COLD WATER—CPVC. PIPING HOT WATER— CPVC PIPING SANITARY— PVC PIPING GAS— METALLIC � . W 1.4 Q J p F— Q at Z C-D a C > W W a o2j o wa=pLd ma- d J Q Q N C W Q U FBI r N 0 o W �¢�zm ,z m 80 V) O 0 M M m 'a N Lj p p� w ¢ w W ¢w z d U pooNV)Q z w ;� 0 N QQ �_jo CD a o ;_E Z? W p (.�U ww00 N= 0 Ln logo#.••''••� 2l •cl- ••'•.LLJ .. •.. �G,,. ,•.LLJ k. ;2> z Q )•. : 5 z O Of w 4 J W d. ' M Q M z o cr cr l N O J � J d � Q W w a �MN CL REVISION 1 1 2 3 4 I 5 6 7 I PROJECT TYPE: RENOVATION SCALE AS SHOWN ISSUED DATE: 03_08_2024 DRAWN BY: A.FENG CHECKED BY: AIIANG SHEET 'F- �L Gam. •�\ �,� V ice,; ZiJ. �c c, \ • .Z.�' c� � Jim • fi,Q�2q! J � ice• ; ! ti i All to- C� Go i f� s T Jr. 2"V. Q�`p��G �� c / sA�C� `' • ''� �T�ti !y �`�sS �syo�� �� �iL ""�� or ?y \ � / �• �� iy�`�`rs �"9iJi�9<< �qC� `�FG�j,T 2"V G �+ a.I• C, F TO • may. c-, T 2 "V. f-__UM BNG SUPPLY RISER DIAGRAM ��• �� �s+��T E 'JkLEXT.S. 2-A.A.V. Sim iJi� ti s � F- fj T SF�i C/ sT O \ s, ygCST2 < . � \�•G+ OOq OT�'9�'T 2"V. \ T O li o PLUMBING SANITARY RISER DIAGRAM SCALEXT.S. Q li V Q J 0O^2L Sj 8 W Q = m �O U Z ^ _ W Q a N U ��— 1— U M� O Qj W-QNZ�O W m C.D W 'Ors C} m l�i J p p W J l F--1 M Q =ciiFa-Woz�- zw Q o~o�' Zooz�Q QQoo�o LAi W c < QU awoo 6> �h O • �� ♦ w .•� �••' ''••tip'• C7 Z 8 p • �, .J. :(7;w 11 co J %••• QLLJ ♦ •• ••• J •• • cn z c2 J 0 d Q w Q 0 J W N pC ^ z 0 W CD z 0 ^ ce- z w w I-1 m Q � G � CL L'7MNa REVISION � I 2 3 4 5 6 7 PROJECT -TYPE: RENOVATION SCALE AS SHOWN ISSUED DATE: 03_08_2024 DRAWN BY: A. FEN G CHECKED BY: A. LI AN G SHEET O Gt G RISER DIAGRAM SCE?+N.T.S. SEDIMENT TRAP 7 GAS PIPING CALCULATION BASED ON TABLE 402.4(2) OF 2020 FBC-GC TOTAL RUN FROM POINTS OF DELIVERY TO THE REMOTE OUTLET(FT):115' TOTAL BTUH= 1,920K NOTE: (2020 FBC-FUEL GAS CODE, SECTION 410.2) 1. A TEE FITTING WITH ONE OPENING CAPPED OR PLUGGED SHALL BE INSTALLED BETWEEN THE MP REGULATOR AND ITS UPSTREAM SHUTOFF VALVE. SUCH TEE FITTING SHALL BE POSITIONED TO ALLOW CONNECTION OF A PRESSURE -MEASURING INSTRUMENT AND TO SERVE AS A SEDIMENT TRAP. 2. A TEE FITTING WITH ONE OPENING CAPPED OR PLUGGED SHALL BE INSTALLED NOT LESS THAN 10 PIPE DIAMETERS DOWNSTREAM OF THE MP REGULATOR OUTLET. SUCH TEE FITTING SHALL BE POSITIONED TO ALLOW CONNECTION OF A PRESSURE -MEASURING INSTRUMENT. GAS CALCULATION NO. CITY. DESCRIPTION BTUH(BTU) TOTAL (BTU) GAS SIZE 1 1 RICE COOKER 35K 35K 3/4" 2 1 7-CHINESE WOK 700K 700K 1-1 /4" 3 3 DEEP FRYER 110K 330K 3/41' 4 1 CONVECTION OVEN 108K 108K 3/41' 5 1 GRIDDLE 150K 150K 3/4" 6 3 EXISTING WATER HEATER 199K 597K 3/4" TOTAL 1,920K U Z oo Q L= Q JpH-Q= N Wyy O w Z Z m C) 4Z.I Q U Z m 0 U o O Q M U � ¢�� N� ~ (� O O w �QNZ�O W mz�NW� v M M W in �U m J O LLI j W 00 l� M Cn Q = tW~WQZr u 25 CUD z w Q° r� O � `d m z �`I QQQO� JO '-� O � � Q Z Z 0 Q W Q = Z m ~ C7�RZQ r-a oo N °' Cr) 0 Ln * tl3'••. .••• CD �P' • QCDO:LLJ t �••� ,.`, ••...�.�.�•• z CD cnl 0 Of CL m LLJ Q 0 .j W elf ' M M o � C) z LLI W W � 69 W F- LLJ REVISION 1 I 2 3 4 5 6 7 I PROJECT TYPE: RENOVATION SCALE AS SHOWN ISSUED DATE: 03_08_2024 DRAWN BY: A.FENG CHECKED BY: A.LIANG SHEET GWH GWH GWH HW CW HW CW HW CW T HW I T T cW HWR WATER HEATER NOTES: HWR — UP TO FAUCET CONNECTIONS THERMAL METER r-' PROVIDE ESCUTCHEONS AT WALL I N I rl C PENETRATIONS. (TYPICAL) � U CD O � NOTE: 1.THE THERMOSTATIC MIXING VALVE THAT CSAB125.3. WATER TEMPERATURE SHALL NOT EXCEED 110 DEG F. WATTS MMV—M 1 (OR EQUAL) FOR SINGLE SINK APPLICATIONS. SUPPLIED WITH REMOVABLE POSITION AND THERMAL METER, SEPARATE CHECK STOPS, ROUGH BRONZE FINISH. INSTALL IN SUPPLY PIPING BELOW FIXTURE. SET TEMPERATURE AT 110OF MIXING. MIXING VALVE PIPING SCHEMATIC SCALE: NONE 1. WATER HEATERS SHALL BE INSTALLED PER MANUFACTURERS INSTRUCTIONS. 2. PROVIDE A TEMPERATURE AND PRESSURE RELIEF VALVE FOR EACH HEATER SIZED PER MANUFACTURER'S RECOMMENDATIONS. 3. COORDINATE INSTALLATION OF ELECTRICAL SUPPLY AND CONTROLLERS WITH THE ELECTRICAL CONTRACTOR. '2 N COLD WATER SUPPLY 31ON TANK. iL ST-25V. BYPASS BALANCING VALVE "B" BYPASS BALANCING VALVE "A" BALANCING VALVE INSTRUCTIONS: 1. THERMOSTATIC MIXING VALVE DOES NOT OPERATE WHEN NO HOT WATER IS BEING DRAWN FROM THE SYSTEM. 2. TEMPERATURE CONTROL IN THE RECIRC LOOP IS ACCOMPLISHED WITH THE BALANCING VALVES. VALVES TO BE FULLY OPENED UPON SYSTEM SETUP AND CALIBRATED DEPENDENT UPON OWNER NEEDS. CLOSE VALVE "A" IF THE HOT WATER IS SPIKING TOO HIGH, CLOSE VALVE "B" IF THE HOT WATER IS TOO COOL. GAS WATER HEATER PIPING DETAIL N.T.S WA 1 80Gf ANIFOLD-SEE PLUMB &OPT&S HOSE ; BALL VALVE 30W QUICK DISCONNECT EQUIP. GAS NIPPLE ELBOW RESTRAINING CABLE BOLT TO WALL STUD & EQUIP. FRAME GAS QUICK DISCONNECT DETAIL SCALE: NONE 3-COMPARTMENT SINK DETAIL SCALE: NONE :Piyj -t-T-—i--•f-5 HWR AQUASTAT/ CLOCK TIMER. LL VALVE TACO MODEL 563. \ HWR' BALL VAL , HOSE BB TACO 0013-F3 HOT WATER RE IRC. CHECKrLVE PUMP (T)o) \ (115 1/6 HP) AQUASTAT INSTRUCTIONS: \ 1. THE TACO AQUASTAT MODEL 563 MOUNTS ON ANY "00" SERIES CIRCULATOR. REF MANUFACTURER FOR FURTHER INFORMATION. 2. SET AQUASTAT CLOCK TIMER TO RUN THE RECIRCULATION PUMP DURING FACILITIES HOURS OF OPERATION. COORD. W/ OWNER. 3. OPTIONAL TEMPERATURE CONTROL SETTING FOR THE AQUASTAT TO RUN THE RECIRCULATION PUMP WHEN TEMPERATURE IN THE PIPE IS BELOW 115' 4. THE CLOCK TIMER IS THE PREFERRED METHOD OF INSTALLATION FOR ALL HWR LINES AND THE ONLY OPTION OFR ALL HWR 140° LINES a 4" ROOF DECK ROUTE VENT PIPING IN CEILING SPACE TO TERMINATE VENT A MINIMUM DISTANCE OF 10' FROM FRESH AIR INTAKES VENT PIPE ROOF MASTIC ROOF DECK PACK W/ OAKUM OR EQUAL MATERIAL TO PREVENT ASPHALT DRAINAGE VENT THRU ROOF DETAIL SCALE: NONE CLEANOUT & ACCESS COVER TO BE FLUSH W/TOP OF FLOOR FINISHED FLOOR 1/8 BEND SOIL PIPE. Y BRANCH SOIL PIPE. C.O. NOT TO BE LOCATED IN CARPETED AREA. SANITARY CLEANOUT TO FLOOR SLAB SCALE: NONE AS NOTED__, HUB DRAIN AND STANDPIPE SCALE: NONE I1 CAST BA"" TILE, 1/4' SLOPE N LATICRE WATERP MEMBRP EPDXY C DRAIN w COLLAR FLOOR FLOOR DRAIN DETAIL SCALE: NONE SELF PRIMING TILE, SLOPE 1/4"/FT. WATERPROOF MEMBRANE CAST IRON HALF GRATE - DOME STRAINER CLAMP RING CONC.—,. FOR SI TYPE, FIXTUF AND SI FLOOR SINK DETAIL SCALE: NONE TYPICAL TRAP PRIMER DETAIL SCALE: NONE U ,cD w U "V � W¢Lu 0 LLJ U Z m 1--i rZ�zo NLLJK O M M m N p p� w Q W l" M N ¢ Q V) � ¢ N�wwZ} �i U= b a o" Z z w Q O m zooz(¢ ¢ ¢ p � 0 000 N = cy Q a w 00 CL rn 0 ''•. .• G CD ■ • co a ■ •.Z o � • C7 J■ O,w • • i O v• ■ J Q Uj ••,. fib'••. J ,.Ft ��• 48 z CD 0 Q W Q 0 J W ' M Q M o � a a J M r•--i Q z o Z kn I W '11l g o a V M W N W JLLJ N a REVISION 1 1 2 3 4 1 5 i 6 7 I PROJECT TYPE: RENOVATION SCALE AS SHOWN ISSUED DATE: 03_08_2024 DRAWN BY: A.FENG CHECKED BY: A.LIANG SHEET 5!j