GENERAL PROJECT NOTES
S even
,3pr
ings
Challenge
1. DO NOT SCALE DRAWINGS. CONTRACTOR SHALL R:::.Y ON WRITTEN DIMENSIONS AS GIVEN. DIMENSIONS SHOWN ARE TO CENTER OF STUD, FINISH FACE OF MASONRY/CONCRETE OR GRID LINES, UNLESS
NOTED OTHERWISE. ALL DIMENSIONS SHALL BE FIELD 'VERIFIED BY THE CONTRACTOR AND COORDINATED WITH ALL OF THE WORK OF ALL TRADES. IF DISCREPANCIES ARE FOUND, THE CONTRACTOR SHALL
NOTIFY THE ARCHITECT IN WRITING FOR CLARIFICATICJ BEFORE THE COMMENCEMENT OR RESUMPTION OF WORK.
2. ABBREVIATIONS THROUGHOUT THE PLANS ARE THOSE IN COMMON USE. NOTIFY THE ARCHITECT OF ANY ABBREVIATIONS IN QUESTION.
3. CONSULTANT DRAWINGS ARE SUPPLEMENTAL TO THE ARCHITECTURAL DRAWINGS. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO COORDINATE WITH THE ARCHITECTURAL DRAWINGS BEFORE THE
INSTALLATION OF ANY OF THE CONSULTANT'S WORK AND TO BRING ANY DISCREPANCIES OR CONFLICTS TO THE ARCHITECTS ATTENTION IN WRITING, FOR CLARIFICATION.
4. THE CONTRACTOR AND SUBCONTRACTORS SHALL PROVIDE ALL NECESSARY PERMITS AND INSPECTIONS. ANY FEES ASSOCIATED WITH, BUT NOT NORMALLY COVERED BY THESE ITEMS, WILL. BE THE
RESPONSIBILITY OF THE CONTRACTOR.
5. THE CONTRACTOR SHALL FURNISH ALL MATERIALS, LABOR, EQUIPMENT, TRANSPORTATION AND SERVICES NECESSARY FOR THE SATISFACTORY COMPLETION OF WORK UNLESS DESIGNATED AS "NOT IN
CONTRACT" (N.1.C.) OR "OWNER FURNISHED, OWNER INSTALLED" (O.F.O.I). ALL EQUIPMENT, WORK AND MATERIALS SHALL COMPLY WITH ALL CURRENT AND LOCAL APPLICABLE CODES AND GOVERNING
REGULATIONS, AND THE CONTRACT DOCUMENTS.
6. THE CONTRACTOR SHALL PROTECT ALL FINISH WORK AND SURFACES FROM DAMAGE DURING THE COURSE OF CONSTRUCTION AND SHALL REPLACE AND/OR REPAIR ALL DAMAGED SURFACES CAUSED BY
CONTRACTOR OR SUBCONTRACTOR PERSONNEL TO THE SATISFACTION OF THE OWNER AND ARCHITECT.
7. UNLESS IT IS SPECIFIED, ACCESS PANELS SHALL BE PROVIDED AND INSTALLED WHEREVER REQUIRED BY BUILDING CODE OR FOR THE PROPER OPERATION OR MAINTENANCE OF MECHANICAL OR ELECTRICAL
EQUIPMENT. WHETHER OR NOT INDICATED ON THE DRAWINGS THE CONTRACTOR SHALL COORDINATE SIZE, LOCATION, AND TYPE OF ACCESS PANEL WITH OTHER CONTRACTORS' WORK. NO ACCESS PANEL
SHALL BE LOCATED, FRAMED OR INSTALLED WITHOUT THE EXPRESSED APPROVAL OF THE ARCHITECT.
8. ANY WORK IMPROPERLY INSTALLED OR INSTALLED IN CONFLICT WITH THE CONTRACT DOCUMENTS SHALL BE CORRECTED BY THE CONTRACTOR AT HIS EXPENSE AND AT NO ADDITIONAL EXPENSE TO THE
OWNER, ARCHITECT, OR CONSULTANTS.
9. THE SIZE, TYPE, SHAPE AND LOCATION OF MECHANICAL EQUIPMENT, FIXTURES, EQUIPMENT PADS AND BASES CONTAINED WITHIN THE CONSTRUCTION DOCUMENTS ARE APPROXIMATE ONLY, UNLESS
SPECIFICALLY NOTED. THE CONTRACTOR SHALL VERIFY DIMENSIONS WITH OTHER TRADES AND/OR THE EQUIPMENT MANUFACTURER.
10. THE CONTRACTOR IS RESPONSIBLE FOR INITIATING, MAINTAINING AND SUPERVISING A REASONABLE AND PRUDENT SAFETY PROGRAM FOR ALL THOSE TRADES PERFORMING WORK ON THE PREMISES. THIS
SHOULD INCLUDE BUT NOT BE LIMITED TO THE ISOLATION OF WORK AREAS AND THE PROMPT REMOVAL OF ANY DEBRIS OR TOOLS WHICH MIGHT ENDANGER VISITORS AND STAFF OF THE OWNER OR ARCHITECT.
11. THE CONTRACTOR SHALL COORDINATE WITH REPRESENTATIVES OF ANY AND ALL UTILITY COMPANIES TO VERIFY AVAILABLE FACILITIES AND, IF APPLICABLE, TO ESTABLISH TEMPORARY FACILITIES.
ADDITIONALLY, THE CONTRACTOR SHALL COORDINATE THE REMOVAL, ABANDONMENT, AND/OR RELOCATION OF EXISTING UTILITIES BOTH ABOVE AND BELOW GRADE WITH THE RESPECTIVE UTILITY COMPANIES.
12. SUBSTITUTIONS: REFERENCE TO MAKERS, BRAND, MODELS, ETC., IS TO ESTABLISH THE TYPE AND QUALITY DESIRED; SUBSTITUTION OF ACCEPTABLE EQUIVALENTS WILL BE PERMITTED IF APPROVED BY THE
ARCHITECT AND OWNER PRIOR TO BID (UNLESS NOTED OTHERWISE).
13. ONLY NEW MATERIALS AND EQUIPMENT OF RECENT MANUFACTURE, OF QUALITY SPECIFIED, FREE FROM DEFECTS, WILL BE PERMITTED ON THE WORK.
14. SHOP DRAWINGS: SHOP DRAWINGS SHALL BE SUBMITTED FOR ALL EQUIPMENT AND MATERIALS WHICH MUST INTERFACE AND COORDINATE WITH OTHERS, WHETHER DETAILED OR NOT.
15. FINAL CLEAN UP AND DISPOSAL: THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REMOVAL OF CONSTRUCTION DEBRIS, RUBBISH AND WASTE MATERIAL FROM THE OWNER'S PROPERTY TO A LAWFUL
DISPOSAL AREA AND PAY ALL HAULING AND DUMPING COSTS. SECONDLY, THE CONTRACTOR WILL OBSERVE ALL TO PERTAINATE FEDERAL STATE AND LOCAL LAWS, REGULATIONS AND ORDERS REGARDING
COMPLETION OF WORK CLEAN-UP. FINALLY, ALL CONSTRUCTION AREAS SHALL BE LEFT VACUUM -CLEAN AND FREE FROM DEBRIS, INCLUDING, BUT NOT LIMITED TO: CLEAN ALL DUST, DIRT, STAINS, HAND MARKS,
PAINT SPOTS, DRIPPINGS, AND OTHER BLEMISHES.
ARCHITECT
DESIGN2907 State Road 590
STYLES Suite 7
Clearwater, FL 33759
ARCHITECTURE p 727.797.4420
f 727.797.9218
designstylesinc.com
OAA0003393
DEVELOPER
PASCO COUNTY
004U MAIN J 1 Ktt I, OUI I t LUU
NEW PORT RICHEY, FL 34652
P# (727) 834-3445
F# (727) 834-3450
I eyst(:) n e
Fund
TABLE OF CONTENTS
PAGE #
DESCRIPTION
SCALE
CS
COVER SHEET
N/A
Al
SITE PLAN
1/8" = 1'-O"
A2
FOUNDATION PLAN
1/4" = 1'-0"
A3
FLOOR PLAN
1/4" = 1'-0"
A4
ROOF FRAMING AND ROOF PLAN
1/4" = 1'-0"
A5
EXTERIOR ELEVATIONS
1/4" = 1'-0"
A6
ELECTRICAL PLAN
1/4" = V-O"
A7
INTERIOR ELEVATIONS
1/2" = 1'-0"
S1
STRUCTURAL DETAILS
SEE SHEET
S2
STRUCTURAL DETAILS
SEE SHEET
S3
STRUCTURAL DETAILS
SEE SHEET
S4
STRUCTURAL DETAILS
SEE SHEET
PA
PRODUCT APPROVAL SHEET 01
N/A
PA
PRODUCT APPROVAL SHEET 02
N/A
PA
PRODUCT APPROVAL SHEET 03
N/A
PA
PRODUCT APPROVAL SHEET 04
N/A
AFFORDABLE HOUSING
3 BEDROOM / 2 BATH
1254 LIVING SQUARE FEET
PROJECT REVISIONS
DESCRIPTION
SHEETS
NO.
AFFECTED
REV.
CODE UPL A ES
ALL
01
SHEETS
UPDATE SLAB NOTE, ADDED SLOPE FOR LANAI, UPDATED
A2
FOOTING SIZE FOR LANAI OPT., UPDATED FOUNDATION B W/
CMU BASE.
CHANGED LANAI DOOR FROM INSWING TO OUTSWING,
ADDED NOTE FOR EXTERIOR CEILINGS, CHANGES PC
A3
LINTELS ON TWO WINDOWS TO BE PC-3, ADDED NOTE FOR
AC TO BE SEER 14, ADDED DRYER VENT NOTE
UPDA1 ED :R1IJSS NOTE, ADDED SCHEMATIC NOTE, UPDATED
DTL 3
A4
UPDATED FLASHING NOTE, UPDATED SOFFIT DETAIL
A5
REMOVED ALL DIMMER FROM FANS, ADDED NOTE FOR
RANGE OUTLET
A6
UPDATED ALL STRUCTURAL NOTES
S1
REMOVED DTL 3, ADDED DTL 7.1
S2
UPDATED NOTE ON 1, ADDED DTL 9.1
S3
REV.
UPDATED SITE PLAN INDICATING SPOT ELEVATION HEIGHTS
Al
02
& SWALE LOCATIONS.
3bi�V JOG
�� -
l
w
0LLrn
o
- W
Q
to
w
owZ
w
N U
W
LL
W H Z
<
W = Q
H
w?�W
0
W V(n
N
0
= Q
zi Ix
w
0
p
rL
w
Q2�
=00
p
Q
FUU
>W
W
u_ZZC,
_
m o
wpz;
?p
p
QQ -
}�mw
wp<W
\
w
wz _j
0w
�z
w�0(L
2LLLLW
.E]
Q`
•
U)
•
C
C
L.L
0cn
•>
C
0
CUW
nC
E
_c
LO
U
M
�-
^♦
W
J
LL
0
uj
_o
cn
L
0
ti
Q
W
it
Na)
Q
C:
j
a
W
:3
O
a.
cn
Q
E
CD
ram•+
O
CD
N
CD
M
0
�
U
W
O
V ,
cn
W
L.L
9-M
ISSUE DATE: 05/06/10
JOB CAPTAIN: JMG
SCALE: AS NOTED
CHECKED BY: JMG/PF
PROJECT NUMBER: 0737
COVER SHEET
(A) - COLONIAL
cs
LIVING F.F.
P/L SWALE
I �
90
189.77'
Z�21
i
TYPICAL SWALE SECTION
N.T.S.
70.00' N 89°30'27" W
1
8" BAY
1
1
4" S
1
CAMPHOUR 0
LOT 5
LOT 18
100" REAR SETBACK
60BAY
I
- - - - - - UTILITY
1
POLE
-- -- --
1
1
1
1
1
1
1
LOT 4 1 o LOT 19
I �
+61� _1� w +
1 +
MI
1 0l
I o
O
z
1 Q 90.02' 90.27' Q 90.02' o
1 w X X im w x LO
MI
w 0 gg,52' DRAINAGE 89.77' DRAINAGE o 89.52'
o to X cn
of o REAR o ( 1
o a CONC. o a 1
z z
cn SLAB
o 75"
90.40 X
89.52' 0 0 CAMPHOUR
LO
89.52'
1 1
20'-0" 40'-0" 10'-0"
R�
+�0
LOT 3 I 90.40' — — — — — — — 90.40' LOT 20
1 I O
z
1
A I A
Al 1 89.27 I 89.27 I Al
-- -- -- 1 W
89.27 Q
PAD
I I �
LOT 2 I I CONC. LOT 21
PAD 1
CAMPHOUR
X
1 CLEAN
OUT
I 89.02' X0 40"
89.02' 89 02X Q i CAMPHOUR
w
30" o I z
CAMPHOUR 00 I o
1
1
q 20'-0"FRONT SETBACK -------------
1 "90.40'
1 q 1
1
x LOT 1 x 88.77' 88.77' LOT 22
1 4'-0" 4'-2" 16'-8" 2'4"
1 1
X
X 88.77' � �'
88.77' 88.77'
� NEW CONC. 88.77
20' A LEY I DRIVEWAY 1
1
I ssso'
70.00' S 89°31'12" E
c� 88.70' 88.60' 88.70' Q46
I
0
36" TREE TO BE
CAMPHOUR WATER REMOVED
OF 10' DIRT ROAD METER 48"
CAMPHOUR
UTILITY 5'-0" N
POLE
SWALE P/L
� I
z 1
90.04'
CO 89.77-1
89.27' 5'-0" h'3
I (MIN.)
ASPHALT R`� (b0b
APRON
4TH AVENUE
60' R/W
411 %l.
1 SITE PLAN
SITE LEGEND:
<— = INDICATES ROOF SLOPE
+-}: = EXISTING ELEVATION
= PROPOSED ELEVATION
SITE DATA BASED UPON SURVEY PROVIDED BY:
EDDIE P. JENKINS SURVEYING AND MAPPING, INC.
4030 HIGHWAY 41 NORTH, LAND 0 LAKES, FL 34639
PHONE: (813) 948-2666
DATE OF SURVEY: 11/06/2009
SITE DATA:
LEGAL DESCRIPTION:
THE EAST 1/2 OF LOTS 19, 20, 21 & 22, AND THE NORTH
1/2 OF THE EAST 1/2 OF LOT 18, BLOCK 178, OF CITY OF
ZEPHYRHILLS, ACCORDING TO THE MAP OR PLAT
THEREOF, AS RECORDED IN PLAT BOOK 1, PAGE 54, OF
THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA.
FLOOD ZONE = "X"
1ST FLOOR FIN FLR ELEV = 0'-0" (91.OT NAVD)
FRONT PORCH FLR ELEV = (-) 0'4" (90.73' NAVD)
REAR SLAB FLR ELEV = (-) 0'4" (90.73' NAVD)
GARAGE FLR ELEV = (-) 0'-6" (90.5T NAVD)
SITE DATA: (PERVIOUS OR GREEN AREA)
TOTAL AREA = 9,454 SQ. FT.
TOTAL BLDG COVERAGE = 1,794 SQ. FT.
(IMPERVIOUS)
DRIVEWAY (IMPERVIOUS) = 447 SQ. FT.
CONCRETE SLABS (IMPERVIOUS) = 140 SQ. FT.
GREEN SPACE REQUIRED = 40.00%
GREEN SPACE PROVIDED = 74.81%
DESIGN
J I Y L r✓J
c
I
li
O
w
t
bA
ARCHITECTURE
2907 State Road 590
Suite 7
Clearwater, FL 33759
designstylesinc.com
p 727.797,4420
f 727.797.9218
#AA0003393
LU
~
o
ZLLo
QON
w
N
0H
co
to
7
CZ0=
HH
in _
w
ow o
z
ToF5
W
LU
N J
wU
11
wX:?
J
<
w = Q
H
0
w�Z
�wLU
j
o
=gW
0
Lj
LL
QCL
=00
o
Q
�UU
u}-wz
_
wo��:
z
0
o
UHmZ
3:Z
pw
w
wow
m Z W J
O
�z
x
LL
O
Al
��
C
">
^C
W
cu
N
E
.c:
U
CM
co
^'
W
J
LL
0
N
O
L
Q
M
^�
W
N
Q
c
U
j
w
�
•o
Q
E
m
O
.c:CD
U
L
CL
N
co
♦>'+
Cn
M
c:
C
O
a)
U
�
o
cn
VJ
ISSUE DATE:
05/06/10
JOB CAPTAIN:
JMG
SCALE: AS NOTED
CHECKED BY:
JMG/PF
PROJECT NUMBER:
SITE PLAN
0737
Al
U
a
a
a
r
g
a
0
0
0
v
io
fV
0
v
0
v
!;tI
N
a-
0
fV
2
S2
1
8" THICKEN EDGE
W/ (1) #5 CONT
16'-0"X8'-0"
CONC. PAD _
7
--N _F
S2
40'-0"
5'-0" 3'-10" 2'-2" 2'-1" 4'-1" 5'-2" 3'-10" 5'-0" 3'-10" 5'-0"
S
Z o
1
I a�clj S2
ELEV
(-) 0'-4"
13 13 13 13 13 13 p 13
I it
ELEV. AT 0'-0" 8" MIN. ABV. GRADE) I
• 4" CONC. SLAB - 3000 PSI, W/ 6X6 p
W1.4/1.4 WELDED WIRE FABRIC I
• 6 MIL VAPOR BARRIER
• MECH. COMPACTED FILL TO 95% OF I
MAX. DRY DENSITY
• TREAT SOIL W/ TERMITE POISONING iv
I
I � p
M I2'-1" I 1'-51/2"
2'-6" 2'-6" 11'-10 1 /2" 8'-0" 2'-6 1 /2" 2'-8" 6'-4 1 /2"
I ( p
- - VERIFY TUB DRAIN
LOCATION WITH
MANUF SPECS
o I p
PROVIDE ELEC/
PLUMBING SERVICE I
THRU SLAB AT PONY I
- - - WALL LOCATION iv
VERIFY TUB DRAIN (REFER TO FLOOR & b
ELEC PLAN)
LOCATION WITH N - I p
Yam- -r
MANUF SPECS
O
6" PONY O � __ HANSEN
WALL ABV
n _
BOX ABV
I Ip
a
n
16"X16" CONC FTG W/ nV---1/4" COPPER WATER 0 W
(2) #5 RODS CONT co a LINE FOR REF I
n � o
" " 8" THICKEN 8'-10" 6'-1^
24 SQ X 12 DP CONC. REF.
FTG. W/ #5 RODS 6" EDGE W/ (1) Li
O
0
"v
0
A
0
v
4'-0"X4'-0"
AC PAD
O
� v
0
"v
O.C. E.W. 8
#5 CONT —
8" THICKEN EDGE W/ - - - - - - - - - - - - - - - - - N
S2 - p
(1) #5 CONT
CV
3'-0"X4'-0" N
p
p
p
p
p p
p
- _ �\ A H U I S2 ELEV.
p
CONC. PAD
13-
ao
ELEV �\ i (-) 0'-6" _
0'-4" i
7
(-) \ 6
\`\\
_
3'-0"
3'-10"
4'-10"
`o
4'-1"
I /�
I U \\ \ \ a S2
�� \
a Nor
8" THICKEN EDGE W/
PVC
o
p
00, 1'-2"
1
`
~
1'-2"
—
9
�,
DIMENSION T
9 DRAIN (1) #5 CONT
S3
FILLED CELL
S3 FOR AHU
6X6 P.T. WD POST
ABV. W/ SIMPSON
- - - - - - - - - - - -
ABU66 AT BASE
o
6X6 P.T. WD POST I I
CONTROL
o
9
8 "
6'-3"
8"
ABV. W/ SIMPSON
JOINT
ABU66 AT BASE
I
ao
13
1
p
N
ED
I
pl
Ip
3/4" DP X 13" WIDE RECESS
I (VERIFY DP W/ BUILDER) I
p
p
4
16"X16" CONC FTG W/
o
v
(2) #5 RODS CONT S2
J
O
HB o
"v
— _
o
pp
pp
p
p
N
11'-1"
7'-7"
1'-10"
10° 16'-0" 10"
1'-10"
18'-8" 21'-4"
0
0o
0
FOUNDATION LEGEND:
NOTE:
BUILDING SLABS SHALL HAVE CONTROL JOINTS IN
ACCORDANCE W/ ACI224-3R
p = FILLED CELL W/(1) #5 VERTICAL
® = FILLED CELL W/(1) #5 TURNED 2'-0" INTO SLAB
0 = FILLED CELL W/(2) #5 VERTICAL
O = FILL CELL TO ONE COURSE ABV PIPE (NO REBAR)
.�.' = (2) 24" #5 REBAR PLACED DIAGONAL AT CORNERS
w
cn
�
Q rn
—
H
o
LL
Q O o
w
N
(Z90Liu:
H
0
w
cn F_ H
w
owZ_
U) O Q
/may
i y
w
�_-NJ
w U
LL
W Z
J
U)
w = Q
H
L u Z
Ewa
O
>Zu)
04
to
= Q Zi �
_�
Q��
LL
Q
4*
_O0
�UU
Qw
Z
�wZ
SQ�
�ro-i
CDC
Z
O
I°mZ
�Z
i
a
m Q w
�a
W
Lu
w Z E J
Q
cn z
Lli O
=LLivi
Hv)
Q
LL
0
a)
��
0)
� >
0
Ac:
W
cu
N
E
Jc:
U
M
M
CL
a)
LL
0
Q)
c:
v�
-
>
a)
_0
V /
LL
^^
>
0
W
�
N
Q
�
U
�,�E�
�
�
�
•°i
O
cl)Q
E
cm
=
0
U
.c:
�
Q.
N
co
U
c*
C
0
4)
U
W
O
VJ
cn
co
a)
ISSUE DATE: 05/06/10
JOB CAPTAIN: JMG
SCALE: AS NOTED
CHECKED BY: JMG/PF
PROJECT NUMBER: 0737
FOUNDATION PLAN
MONO
FOUNDATION PLAN (A
1 /4„ = 1'-011
40'-0"
A2
`v
N
ti
M
16-0"XV-0"
CONC. PAD
40'-0"
5'-4" T-2" 2'-6" 2'-5" T-5" 5'-10" T-2" 5'-8" T-2" 5'4"
0�4
-2
PC-3 PC-2 1 PC-3
EGRESS c3 S2 EGRESS
SH 25 SH 25 SH 25
HD AT 6'-8" D AT 6'-8" HD AT 6'-8"
HB
O
BEDROOM #2 MASTER SUITE
11'-8" X 10'-1" 12'-0" X 14'-2"
I7 8'-0" CLG 8'-0" CLG
2'-10" 9'-10" 14'-4" 8'-4" 4'-8"
2
PC-2 +
SH 23
HD AT 6'-8"
OBSCURED
GLASS
S2
(2) 2668 BF
(1)R&S
10" WALL
24" T.B. A7
2"
A7 7
1 �
F-
__ (1)R&S —_
(2) 2668 BF
GREAT ROOM Lo
14'-2" X 20'-6"
8'-0" CLG I'l
M N
3os8 BATH #1
8'-0" CLG
BATH #2 "' 9'-10"
8'-0" CLG a
8'-8" 4'
BEDROOM #3
11'-8" X 10'-1"
8'-0" CLG
2 BEAMS TO C.M.U.
S2 W/ SIMPSON MGT —�
EGRESS
0 0
PC-3 10
SH 25 S3
HD AT 6'-8"
T-4" T-2" 6'-8"
(2) P.T. 2x12 BEAM'S /
ABV, BOTT AT 8'-0"—
10" SQ HB&G
COLUMN W/ TUSCAN 9
BASE & CAP S3
11
NOTE: S3
EXTERIOR CEILING
FINISHES PER SPECS
11'-1"
18'-8"
48" HIGH 6" PONY H w o
LOW WALL WALL 24" 3 A7Q �'p Z "'
s� LL:
o T.B. A7 LL
00 co 2"
C° 10" WALL
F.F. LINE - (5 16" 2068 BF O� - - LMI'DW
------�SH (5)3068 BF
I
12" DP
o A7 SH ABV
6 KITCHEN a HANSEN BOX
A7 8'-0" CLG CD
4'-5" 9'-11" M 41-2" 6'-1■
DRYE
R o
FOYER A7 5 VENTi�
8'-0" CLG REF �O7
• 0
M MICRO `�6" WALL(1) R & S
PC-2
3068 io AH U W H 6'J ' 5 LT
e V/, N n . INSULATED S2 N
�TI i �4-
S3
1 3'-5" 20
ENTRY
10" WD
SOFFIT ABV
(2) P.T. 2x12 BEAM'S
ABV, BOTT AT 8'-0"
g" 6'-3"
6X6 P.T. WD
POST W/
SIMPSON ABU66
AT BASE &
SIMPSON
ECCLL3 1/4 - 6
AT TOP OF POST
T-7"
WALL
p0
6' UTILITY RM —
d 6'-6" X 6'-6"
8'-0" CLG
4'-4" 16'-4"
BEAMS TO C.M.U.
W/ SIMPSON MGT F —" "
�6X6 P.T. WD POST W/ 22.5 X 54
SIMPSON ABU66 AT A TTIC ACCESS
AS3
BASE & SIMPSON
ECCLR3 1/4 - 6 AT
TOP OF POST
GARAGE
20'-0" X 23-0"
- 1 PC-4
16070
2'-8" 16'-0"
21'-4"
6
S2
0
O
N
lr
■
IDia ■
TIE BEAM
AT 8'-0"
IT
M
M
NOTE:
A/C UNIT W/ HEAT
PUMP TO BE 14 SEER
4'-0"X4'-0"
AC PAD
,-- W.I.C.
5'-0" X 8'-10"
8'-0" CLG
NOTE:
VENT DRYER
THROUGH THE
ROOF
PC-2
3068co
3'-0"X4'-0"
CONC. PAD
0
co
0
GENERAL NOTES:
ALL WINDOWS TO HAVE FLUSH SILLS. PITCH TOP SILL
FIN AWAY FROM WINDOW FRAME.
VERIFY ALL WINDOW AND DOOR ROUGH OPENING SIZES
WITH THE MANUFACTURER'S SPECIFICATIONS.
INSTALL RND DRYWALL BEADS AT HORIZ & VERT
CORNERS, EXCEPT AT EXT WALL OPENINGS OR AS
NOTED.
USE SQUARE CORNER BEAD AT DRYWALL NICHES &
REC CLG DETAILS; REC CLG SURFACES SHALL HAVE
SMOOTH FINISH.
LOCATE ALL PLUMBING & EXHAUST STACKS BEYOND
THE FRONT ELEV ROOF RIDGES, IF ALLOWABLE PER
CODE.
THE GARAGE IS TO BE SEPARATED FROM ADJACENT
LIVING AREA AND ATTIC SPACE BY 1/2" GYPSUM BOARD
AND HABITABLE ROOMS ABOVE BY NOT LESS THAN 5/8"
THK. TYPE "X" GYPSUM BOARD (OR EQUIVALENT)
APPLIED TO THE GARAGE SIDE.
TOWEL BAR - (T.B.) = 56" A.F.F.
TOWEL BAR ABV. TUB DECK = 36" ABV. TUB DECK
TOILET PAPER DISP. - (T.P.) = 20" A.F.F.
ROD AND SHELF (SGL)- (R/S) = 60" A.F.F.
ROD AND SHELF (DBL)- (R/S) = 40" & 80" A.F.F.
CORNER SHELF = 56" A.F.F.
MEDICINE CABINET - (M.C.) = 75" TO TOP OF
CABINET A.F.F.
• PROVIDE BLOCKING FOR OPTIONAL HANDRAILS
LOCATED IN ALL BATHROOMS. SEE BLOCKING
DETAIL FOR LOCATIONS PER INTERIOR ELEVATION
• ALL WINDOWS, EXTERIOR DOORS AND GARAGE
DOOR TO BE RATED AT 130 M.P.H. IMPACT
WALL LEGEND:
ALL EXTERIOR WALLS TO BE CONSIDERED SHEAR
RESISTANT COMPONENTS.
8" CMU W/ 1X2 FURRING STRIP, 3/4"
113 INSUL BOARD & 1/2" GYP
8" CMU
NON -BEARING 2X4 STUDS AT 16"
O.C. W/ 1/2" GYP. OR U.N.O.
BEARING WALL 2X4 AT 16" O.C.
W/ 1/2" GYP. OR U.N.O.
p = FILLED CELL W/(1) #5 VERTICAL
0 = FILLED CELL W/(1) #5 TURNED 2'-0" INTO SLAB
A = FILLED CELL W/(2) #5 VERTICAL
0 = FILL CELL TO ONE COURSE ABV PIPE (NO REBAR)
SQUARE FOOTAGE:
FIRST FLOOR LIVING = 1254 SQ. FT.
TOTAL LIVING SQ FT = 1254 SQ. FT.
ENTRY A = 32 SQ. FT.
LANAI SLAB = 128 SQ. FT.
GARAGE = 508 SQ. FT.
TOTAL SQ FT = 1922 SQ. FT.
w
Qoo
o
N
0 =
8
to
cn F-
w
OWZ
H
Now
1:
w
N J
U
Q
W Z
J
U
w = Q
H
O
w�lz
>Ufn
N
Lo
O
w
=OO
d
�wz
�u�
r,/
Z�
_
U 00
m~QLu
<a
w
z
o W
w
mo-15
E 9
%I
z
_ Il LL cn
mo
c
LL,
,0
(D
W
cu
E
.r.
M
U
co
^'
W
_1
LL
0
(1)
uj
_O
L
0
0
co
co
^^
0
W
�
".
Q
C
U
W
=
.o
cl)Q
E
0
.c:
CD
U
L
Q_
CV
co
�
Cn
m
c:
0
D
U
W
0
cn
VJ
^♦
W
^^cu
I..L
ISSUE DATE: 05/06/10
JOB CAPTAIN: JMG
SCALE: AS NOTED
CHECKED BY: JMG/PF
PROJECT NUMBER: 0737
FLOOR PLAN
FIRST FLOOR PLAN (A
1 /411 = 1'-0„
40'-0"
A3
a
EXTERIOR "
CEILING
FINISH PER
SPECS
STUCCO —
FINISH PER
EXT. ELEV.
3
SCHEMATIC DESIGN ONLY I
ROOF TRUSS LAYOUT IS A SCHEMATIC DESIGN ONLY.
TRUSS LAYOUT AND TRUSS SHOP DRAWINGS MUST BE
REVIEWED AND APPROVED BY DESIGN STYLES, INC. AND/
OR THE ENGINEER OF RECORD PRIOR TO CONSTRUCTION.
TRUSS NOTES: I
THE ROOF TRUSS LAYOUT ON THESE PLANS ARE
SCHEMATIC DESIGN ONLY. FINAL FLOOR AND ROOF
TRUSS LAYOUTS TO BE DEVELOPED BY TRUSS
MANUFACTURER. TRUSS LAYOUTS AND TRUSS SHOP
DRAWINGS MUST BE REVIEWED AND APPROVED BY
DESIGN STYLES, INC. AND/ OR THE ENGINEER OF
RECORD PRIOR TO CONSTRUCTION.
TRUSS MANUFACTURER TO VERIFY ADEQUACY OF
ALL SPECIFIED LVL BEAMS AND MAKE ANY
ADJUSTMENTS NECESSARY DUE TO FINAL TRUSS
DESIGN OR CALCULATED REACTIONS. ALL
MODIFICATION TO BE REPORTED TO DESIGN STYLES,
INC. AND THE ENGINEER OF RECORD PRIOR TO
CONSTRUCTION.
ELECTRICAL & HVAC LAYOUTS ARE BASED ON THESE
FRAMING LAYOUTS. ANY DEVIATIONS ARE TO BE
APPROVED BY DESIGN STYLES, INC. PRIOR TO
CONSTRUCTION.
TYPICAL TRUSS CONNECTORS
1. ALL CONNECTORS ARE "SIMPSON, STRONG -TIE".
2. USE MTS20'S FOR ROOF TRUSS TO FRAME
CONNECTIONS.
3. ATTACH ALL FRAMING ABOVE ROOF TRUSSES TO
TRUSSES W/ MTS16'S.
4. USE HHETA20 FOR ROOF TRUSS TO MASONRY
CONNECTIONS.
5. USE (2) HHETA20 FOR GIRDER TRUSS TO MASONRY
CONNECTIONS.
6. USE (2) HTS30 FOR GIRDER TRUSS TO FRAME
CONNECTIONS.
7. THE PREVIOUS CONNECTORS APPLY UNLESS
OTHERWISE NOTED.
8. SEE FLOOR PLAN AND FOUNDATION SHEETS FOR
OTHER CONNECTIONS.
DESIGN STYLES, INC. AND THE ENGINEER RESERVE
THE RIGHT TO MAKE ANY CHANGES AFTER FINAL
TRUSS INFORMATION IS SUPPLIED FROM TRUSS
MANUFACTURER.
TIE BEAM / PLATE LEGEND: I
= TIE -BEAM AT 6-0"
I ROOF VENT CALCULATIONS 11
NOTE: VERIFY WITH GENERAL CONTRACTOR ALL ROOF VENT
LOCATIONS, QUANITIES, AND SIZES. ROOF VENTS SHALL BE
INSTALLED FOR A MIN. OF VENTED AREA AS LISTED BELOW
OR EQUIVALENT SYSTEM PER F.B.C. 2007 SECTION R806
IATTIC AREA = 1762 1
IVENTILATION PROVIDED AT RIDGE = 432 1
IVENTILATION PROVIDED AT SOFFIT = 422 MIN.
IV[ 1 L. Vr[Ir" CLJVC
2X6 SUB -FASCIA
ALUMINUM OR
VINYL FASCIA
PERFORATED
ALUMINUM OR VINYL
SOFFIT VENT
TRUSS DETAIL AT ENTRY
1 11 = 1 '-011
(2) P.T. 2X12 BEAM
6X6 P.T. BEYOND
1X3 STUCCO BAND
10" SQ. HB&G COLUMN
BEYOND
w
cn
Orn
�
o
Q 0
N
w
N
F—
w
C-90=
0
`n
Fn H I•-
0 w Z
z
H
LoFn
w
N J
UJ U
Q
w Z
J
<
w = Q
H
O
wow
Iwo
j U U)
o
= Q w
0
Q�0
=00
�UU
-1
>J -
,w
>- z o
U- —z
- r
tn�
�m
Ovi ��;
O
UO65Z
�z
m~Q2
�a
z w
o w
cn z
=0_jD
H2LL
Q
C
c
L
"0
^♦
.0
">
c
0
cu
^C^'
W
E
M
U
M
J
u_
0
(1)
uj
�
O
�
_
LL
^�
C2.
W
�*
.�..�
N
Ix
Q
m
1
j
�
E
O
Q
E
��--+
0
.�
U
N
Cn
ch
=3
C
0
a)
CU
QD
o
U)
cn
co
Jc
F_
ISSUE DATE: 05/06/10
JOB CAPTAIN: JMG
SCALE: AS NOTED
CHECKED BY: JMG/PF
PROJECT NUMBER: 0737
ROOF FRAMING &
ROOF PLAN (A)
A4
ROOF FRAMING PLAN (A
1 /4" = 1'-0„
ROOF PLAN (A
1 /4" = 1 '-0"
v
0
00
ELEV AT 15'4"
TOP OF RIDGE
ELEV AT 10'-0"
ENTRY HEEL
_
0
"' ELEV AT 8'-0"
1ST FLOOR CLG
1" X 6" BAND
18" WD SHUT
0
00
1" X 3" BAND
DECORATIVE
CEMENTITIOI
COATING TYI
ELEV AT 0'-0"
1 ST FLOOR FF
F_
0
co
......••.•�.•..��.,._. IWINDOW TRIM
FRONT ELEVATION (A) - COLONIAL
1 /411 = 1'-0„
ELEV AT 15'-4"
TOP OF RIDGE
ELEV AT 8'-0"
1ST FLOOR CLG
A/C UNIT
ELEV AT 0'-0" A/C PAD
1ST FLOOR FF
12
5
ELEV AT 164"
TOP OF RIDGE
ELEV AT 8'-0"
1 ST FLOOR CLG
1" X 6" BAND SEE
DETAIL 7/A5
DECORATIVE
CEMENTITIOUS
COATING TYP., U.N.O.
ELEV AT 0'-0"
1 ST FLOOR FF
ELEV AT 15'-4"
TOP OF RIDGE
ELEV AT 8'-0"
1 ST FLOOR CLG
DECORATIVE
CEMENTITIOUS
COATING TYP., U.N.O.
ELEV AT 0'-0"
1 ST FLOOR FF
2 REAR ELEVATION A - COLONIAL
111
1/4 -1-0
ELEV AT 164" _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ ELEV AT 15'-4"
TOP OF RIDGE TOP OF RIDGE
�---INSIDE PITCH AT 4:12
ELEV AT 8'-0"
1ST FLOOR CLG - - - - - - -
0
DECORATIVE OBSCURED
CEMENTITIOUS GLASS
COATING TYP., U.N.O.
ELEV AT 0'-0" _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
1ST FLOOR FF
LEFT ELEVATION (A) - COLONIAL
1 /4„ — 1'-Oft
_ ELEV AT 164"
TOP OF RIDGE
ELEV AT 8'-0"
1 ST FLOOR CLG - - - - -
oa
DECORATIVE
CEMENTITIOUS
COATING TYP., U.N.O. CO
ELEV AT 0'-0"
1ST FLOOR FF
ELEV AT 10'-0"
ENTRY HEEL
ELEV AT 8'-0"
- - - - - - - 1 ST FLOOR CLG
1"X3"BAND
DECORATIVE
CEMENTITIOUS
COATING TYP., U.N.O.
-10" SQ HB&G COLUMN W/
TUSCAN BASE & CAP
ELEV AT 0'-0"
1 ST FLOOR FF
ELEV AT 15'-4"
TOP OF RIDGE
I�I�IIIr1�111�1■IDrI�l1�rI�111�1■111���.__12
11�I�11 1�1�11�111rlrlllrl�llr�i�.._ELEV AT 81
�Lll�linn
FLOOR LG
MY-4-
-A/C UNIT
A/C PAD _ _ _ _ _ _ _ _ _ _ ELEV AT 0'-0"
1 ST FLOOR FF
FLASHING NOTES:
DUE TO CLARITY NOT ALL REQUIRED FLASHINGS
ARE INDICATED ON DRAWINGS. REFER TO CURRENT FBC
RESIDENTIAL, SECTION R703.8. APPROVED
CORROSION -RESISTIVE FLASHING SHALL BE PROVIDED
IN THE EXTERIOR WALL ENVELOPE IN SUCH A MANNER
AS TO PREVENT ENTRY OF WATER INTO THE WALL
CAVITY OR PENETRATION OF WATER TO THE BUILDING
STRUCTURAL FRAMING COMPONENTS. THE FLASHING
SHALL EXTEND TO THE SURFACE OF THE EXTERIOR
WALL FINISH AND SHALL BE INSTALLED TO PREVENT
WATER FROM REENTERING THE EXTERIOR WALL
ENVELOPE. APPROVED CORROSION -RESISTANT
FLASHINGS SHALL BE INSTALLED AT ALL OF THE
FOLLOWING LOCATIONS:
1. AT TOP OF ALL EXTERIOR WINDOW AND DOOR
OPENINGS IN SUCH A MANNER AS TO BE LEAKPROOF,
EXCEPT THAT SELF -FLASHING WINDOWS HAVING A
CONTINUOUS LAP OF NOT LESS THAN 1-1/8 INCHES (28
MM) OVER THE SHEATHING MATERIAL AROUND THE
PERIMETER OF THE OPENING, INCLUDING CORNERS, DO
NOT REQUIRE ADDITIONAL FLASHING; JAMB FLASHING
MAY ALSO BE OMITTED WHEN SPECIFICALLY APPROVED
BY THE BUILDING OFFICIAL.
2. AT THE INTERSECTION OF CHIMNEYS OR OTHER
MASONRY CONSTRUCTION WITH FRAME OR STUCCO
WALLS, WITH PROJECTING LIPS ON BOTH SIDES UNDER
STUCCO COPINGS.
3. UNDER AND AT THE ENDS OF MASONRY, WOOD OR
METAL COPINGS AND SILLS.
4. CONTINUOUSLY ABOVE ALL PROJECTING WOOD
TRIM.
5. WHERE EXTERIOR PORCHES, DECKS OR STAIRS
ATTACH TO A WALL OR FLOOR ASSEMBLY OF
WOOD -FRAME CONSTRUCTION.
6. AT WALL AND ROOF INTERSECTIONS.
7. AT BUILT-IN GUTTERS.
GENERAL NOTES:
* LIGHT TEXTURED FINISH AT MAIN BODY TYP., U.N.O.
* ALL BANDING TO BE SAND FINISH TYP., U.N.O.
e
c') T-0"
ch
w
�
H
p 0>
o
Q O N
N
(Dp=
o
cc
to
F-
in -
w
0WZ
fop
w
w
N J
W U
Q
W = Z
-1�
W = Q
H
O
wow
�Wp
j Z to
-
o
=Qui
0
- a w
U-
Q
=00
zi _
L)
aW
�Zz
�� `'
w
w
w0��
C9cn �.
�p
O
p
m�mw
p 0
�a
p
w — —i
U) Z
=0o LL�
Q
H�
mo
C
C
LL.
0
"cl)
Al
",
0
^c:
W
c:
cu
N
QD
E
M
U
M
U-
0
a)
uj
-
_0
ZE
O
ti
0
W
N
Q
C
U
w
w.
�
E
•o
cf)
Q
E
0)a
0
CD
L
CL
N
co
Cn
M
=3
c:
0
0
0
^/
W
O
VJ
cn
Al
W
IZ-
ISSUE DATE: 05/06/10
JOB CAPTAIN: JMG
SCALE: AS NOTED
CHECKED BY: JMG/PF
PROJECT NUMBER: 0737
EXTERIOR
ELEVATIONS (A)
RIGHT ELEVATION (A) - COLONIAL
1 /4„ = 1'-0„
A5
2'-8 1 /2" �, 2'-8 1 /2"
ELECTRICAL PLAN
1 /4„ = 1'-011
ELECTRICAL LEGEND:
NOTE: ALL HEIGHTS ABOVE FINISH FLOOR
110V DUPLEX OUTLET AT 18" NOTE: ALL
110V DUPLEX OUTLET AT 39" RECEPTACLES
110V DUPLEX OUTLET AT 43" ABOVE
110V DUPLEX OUTLET AT 45" COUNTERS
SPLIT 110V DUPLEX OUTLET SHALL BE
AT 12" - TOP PLUG IS HOT MOUNTED
HORIZONTAL
110V QUAD OUTLET AT 12"
WEATHERPROOF GFCI OUTLET AT 12"
220V OUTLET AT 30"
110V DUPLEX FLOOR OUTLET
® OUTLET - VERIFY W/MANUF. SPECS
FOR LOCATION & TYPE
TELEPHONE OUTLET AT 12" OR AS NOTED
TELEVISION OUTLET AT 12" - WIRE FOR
CABLE & SATELLITE
® STRUCTURED WIRE OUTLET
SWITCH AT 48"
3 WAY SWITCH AT 48"
4 WAY SWITCH AT 48"
—0 PUSH BUTTON FOR GARAGE DOOR OPENER
--o DIMMER SWITCH AT 48"
--fl PUSH-BUTTON DOORBELL
-�- CLG MNT LT FIXTURE
} CLG MNT PREWIRE - FIXTURE BY OWNER
{} SURFACE MNT FIXTURE
{ WALL MNT FIXTURE
O 40W A 6" ROUND OPALEX - NOTE:
TUB/SHOWER ALTERNATE
50W PAR30 NFL 6" WHITE BAFFLE CANS MAY BE
USED IF
50W MR16 4" LOW VOLTAGE APPROVED BY
OWNER
®' 50W PAR20 NFL 4" MINI ROUND RECESS
io 50W PAR20 NFL 6" RD REGRESSED BAFFLE EYEBALL
} CLG FAN PREWIRE AND SWITCH
® COMBINATION CARBON MONOIXED DETECTOR/
SMOKE DETECTOR
°U-182 UNDER CABINET 18"
cS-18m SINGLE 18" FLUOR STRIP
=U-24- UNDER CABINET 24"
=S-24= SINGLE 24" FLUOR STRIP
=D-24= DOUBLE 24" FLUOR STRIP
U-36 = UNDER CABINET 36"
S-36 = SINGLE 36" FLUOR STRIP
— D-36 = DOUBLE 36" FLUOR STRIP
S-48 SINGLE 48" FLUOR STRIP
D-48 DOUBLE 48" FLUOR STRIP
24 24"CLG MNT WRAPPED FLUOR LIGHT
48 48"CLG MNT WRAPPED FLUOR LIGHT
= 24 = 24" VANITY LIGHTING
36 == 36" VANITY LIGHTING
_48- 48" VANITY LIGHTING
0 EXHAUST FAN/LIGHT
O EXHAUST FAN
VCp DOUBLE FLOOD LIGHT W/ COVERS AND
150W PAR 38 FL
INTERCOM SPEAKER AT 5'-0" ABV FINISH FLOOR
0 CEILING MNT SPEAKER
El CHIMES (DELETE W/ INTERCOM)
® MASTER STATION
N&3 ELEC PANEL
0 VACUM OUTLET AT 12"
® CEILING RETURN AIR
A/C REGISTER
® THERMOSTAT
® SECURITY PAD
ELECTRICAL NOTES:
1. GFCI'S ARE TO BE INSTALLED IN THE FOLLOWING
LOCATIONS AS SPECIFIED PER N.E.C. 210.8
A)BATHROOMS
B) GARAGES, AND ALSO ACCESSORY BUILDINGS THAT
HAVE A FLOOR LOCATED AT OR BELOW GRADE
LEVEL NOT INTENDED AS HABITABLE ROOMS AND
LIMITED TO STORAGE AREAS, WORK AREAS, AND
AREAS OF SIMILAR USE.
C) CRAWL SPACES AT OR BELOW GRADE.
D) KITCHENS - WHERE THE RECEPTACLES ARE
INSTALLED TO SERVE THE COUNTERTOP
SURFACES.
E) LAUNDRY, UTILITY, AND WET BAR SINKS - WHERE
THE RECEPACLES ARE INSTALLED WITHIN 6 FEET
OF THE OUTSIDE EDGE OF THE SINK.
2. ARCH FAULT OUTLETS ARE REQUIRED IN ALL
BEDROOMS AS SPECIFIED PER N.E.C. 210.12
3. ANY CONFLICTS BETWEEN LOCATION OF MECHANICAL
FIXTURES ON PLANS AND THE ABILITY TO LOCATE THEM
IN THE FIELD MUST BE REPORTED TO THE ARCHITECT
PRIOR TO INSTALLATION.
INTERCOM SPEAKER
ALIGNED W/ EDGE
OF SWITCH
SWITCH
DOOR
JAMB 41/2"
DUPLEX
OUTLET q
-v
TRIM
BASE
TRIM
NOTE:
ALL DIMENSIONS ARE FROM
ROUGH FRAMING
ELECTRICAL DETAIL
1/2 if = 1'-0"
73
C
L
"0
cn
">
0
^C
cu
E
U
CM
M
Q
W
"J
�.L
0
N
cn
0
Q
r�M
(
Q
W
♦..�
W
Q
CD
O
c:
U
i
CL
CD
c
C )
co
C
1
U
W
O
)
V
m
•
ISSUE DATE: 05/06/10
JOB CAPTAIN: JMG
SCALE: AS NOTED
CHECKED BY: JMG/PF
PROJECT NUMBER: 0737
ELECTRICAL PLAN
A6
0
00
5'-0" 6"
BATH #2
-0"
SHOWER
HEAD
ROD
33" X 37"
DECO
o MIRROR
3"
a0 BACKSPLASH 4.1
o A7
VALVE
As SPIGOT
P.
co
04 0
2" FILLER—,2'-6" 2'-6" 2'-6"
BATH #2
2 112" =1' 0"
"HANSEN" 220 VOLT
BOX
F_ o� F_ --�
I — I -- ° ---!
W D
14 1/2" X 16"
DRYER VENT
RECESS
UTILITY ROOM
5 112" =1' 0"
42"
24"
LX I MIN
MINIMUM
REINFORCED
AREA o0
N M
co
MINIMUM REINFORCING AT
SIDE OF TOILET
BLOCKING DETAILS
1/2" =1'-0"
v
0
0o
cn
2
0
6" 5'-0"
BATH !_O
13 1l2" =1 �-
NER
N
P
=
-
I
00
00
✓E o0
CID
OT
i-
SHOWER
HEAD
VALVE
SPIGOT
0
2'-6"00 2'-7"
BATH #1
1 /2" = 1'-0"
CO
I
4.1
4" A7 - -- o
BACKSPLASH 0°
= DO 00
o
DW o 0
c� cnLJ
Ll
6" 1'-3" 3'-0" 2'-0" 2'-9" 2 1/2" FILLER
2 1/2" FILLER
KITCHEN
6 1/2" = l'-0"
18"
12" I 12'
1. MINIMUM
MIN MIN REINFORCED
AREA
i
z_
c0
N CO
MINIMUM REINFORCING BEHIND TOILETS
LOCATED BESIDE A WALL
6" MAX
10 48" MIN
MINIMUM
REINFORCED
AREA
36" X 37"
DECO
MIRROR
3"
BACKSPLASH
T.P
Ll
1'-10" V-8"
2" 6° 1, 1
6.1 HIGHBAR SECTION
1/2' -1-0
BACK WALL HEAD WALL
REINFORCED AREAS REQUIRED AT
CONVENTIONAL BATHTUBS
2'-9"
ICED
0
m
2" FILLER
2" FILLER
2" FILLER-
IN ADJACENT WALL IN ADJACENT CABINET
NOTE: PROVIDE TOILET PAPER DISPENSER IN WALL WHENEVER POSSIBLE
TOILET PAPER DISPENSER DETAILS
1/2" =1'-0"
&16i -o
c -o
i- i v
J -J
,. /
0
MICRO REF.
0
4"
BACKSPLASH
0
2'-6"
1'-9"
T-5"
KITCHEN
1l2" =1'-0"
1
ICED
2" FILLER
MINIMUM
REINFORCED
AREA
BACK WALL SIDE WALL
MINIMUM REINFORCING FOR GRAB BARS IN SHOWERS (NOTE: GLASS
ENCLOSURE WALLS DO NOT REQUIRE GRAB BARS)
L
O
"
(D
V )
">
C
cu
N
E
M
U
M
^♦
W
J
�.L
0
0
(1)
-0-0 (1)
E
LL
0
ti
ti
>_c
a)
Q
0
W
�0
♦..r
0
N
Q
11
C:
=3
�
•O
v♦
Q
E
O
._
C
U
L-
N
00
�
Cn
ch
i
O
(1)
U
�
o
v ,
m
�
®
1
1: � 1•
ISSUE DATE: 05/06/10
JOB CAPTAIN: JMG
SCALE: AS NOTED
CHECKED BY: JMG/PF
PROJECT NUMBER: 0737
INTERIOR
ELEVATIONS
A7
FLORIDA BUILDING CODE REQUIREMENTS
ONE AND TWO FAMILY RESIDENTIAL STRUCTURES
s
x
THE STRUCTURES INCLUDED IN THESE DESIGN DRAWINGS SHALL CONFORM TO THE 2007 FLORIDA
29 8
RESIDENTIAL CODE PLUS ALL SUPPLEMENTS.
0
A. WINDOW AND DOOR REQUIREMENTS - FBC CHAPTER 6 R613
Q
A. 1. - ALL EXTERIOR WINDOWS AND GLASS DOORS SHALL BE TESTED IN ACCORDANCE WITH
ANSI/AMMA/NWWDA 101/IS2 STANDARDS AND SHALL BEAR AN AMMA AND WDMA LABEL
IDENTIFYING MANUFACTURER, PERFORMANCE CHARACTERISTICS AND APPROVED PRODUCT
F
TESTING ENTITY.
A.2. - WINDOW AND DOOR INSTALLATION SHALL BE AS SHOWN ON DETAILS AND SHALL INCLUDE
THE FOLLOWING:
A.2.1 - ANCHORING AS PER PUBLISHED MANUFACTURER'S RECOMMENDATIONS FOR THE
DESIGN PRESSURE STATED HEREIN.
A.2.2 - IF BUCK THICKNESS IS LESS THAN 1 1/2 INCHES, ANCHORING SHALL PENETRATE THE
JAMB INTO THE STRUCTURAL SUBSTRATE. ANCHORING SHALL BE INSTALLED WITH A
o
MINIMUM PENETRATION OF 1 1/4 INCHES INTO MASONRY OR CONCRETE WALLS OR AS
PER MANUFACTURER'S RECOMMENDATIONS.
A.2.3 - IF BUCK THICKNESS IS MORE THAN 1 1/2 INCHES, REFER TO WINDOW
ATTACHMENT DETAIL.
A.2.4 - WINDOW BUCK SHALL EXTEND BEYOND THE INTERIOR LIP OF THE WINDOW AS SHOWN
ON WINDOW ATTACHMENT DETAIL.
A.2.5 - MULLIONS AND ADJACENT DOOR ASSEMBLIES SHALL BE TESTED FOR 1.5 TIMES THE
DESIGN LOADS. MULLIONS SHALL BE INSTALLED IN ACCORDANCE WITH
MANUFACTURER'S RECOMMENDATIONS.
to
g
A.3. - SEE WINDOW AND DOOR SCHEDULE FOR MODEL NUMBER AND MANUFACTURER.
A.4. - GARAGE DOOR SHALL BE DESIGNED FOR THE WIND LOAD REQUIREMENTS. GARAGE DOOR
o
ANCHORING AS PER PUBLISHED MANUFACTURERS RECOMMENDATIONS FOR THE DESIGN
PRESSURE STATED HEREIN.
co
b
B. - A FOUNDATION SURVEY SHALL BE PERFORMED AND A COPY OF THE SURVEY SHALL BE ON THE SITE
FOR THE BUILDING INSPECTION USE, OR, ALL PROPERTY MARKERS SHALL BE EXPOSED AND A
STRING ATTACHED FROM MARKERS TO VERIFY REQUIRED SETBACKS.
co
m
C. - ALL PLUMBING, ELECTRICAL AND MECHANICAL ROUGH -INS MUST BE COMPLETE, INSPECTED AND
g
APPROVED BEFORE REQUESTING THE FRAMING INSPECTION.
m
D. TERMITE TREATMENT
SECTION R320 OF THE 2007 FLORIDA BUILDING CODE RESIDENTIAL
PROTECTION AGAINST TERMITES
R320.1 TERMITE PROTECTION SHALL BE PROVIDED BY REGISTERED TERMITICIDES, INCLUDING SOIL
APPLIED PESTICIDES, BAITING SYSTEMS, AND PESTICIDES APPLIED TO WOOD, OR OTHER APPROVED
METHODS OF TERMITE PROTECTION LABELED FOR USE AS A PREVENTATIVE TREATMENT TO NEW
CONSTRUCTION (SEE SECTION 202, REGISTERED TERMITICIDE). UPON COMPLETION OF THE APPLICATION
OF THE TERMITE PROTECTIVE TREATMENT, A CERTIFICATE OF COMPLIANCE SHALL BE ISSUED TO THE
BUILDING DEPARTMENT BY THE LICENSED PEST CONTROL COMPANY THAT CONTAINS THE FOLLOWING
STATEMENT: "THE BUILDING HAS RECEIVED A COMPLETE TREATMENT FOR THE PREVENTION OF
SUBTERRANEAN TERMITES. TREATMENT IS IN ACCORDANCE WITH RULES AND LAWS ESTABLISHED BY THE
FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES."
R320.1.1 IF SOIL TREATMENT USED FOR SUBTERRANEAN TERMITE PREVENTION, THE INITIAL CHEMICAL
SOIL TREATMENT INSIDE THE FOUNDATION PERIMETER SHALL BE DONE AFTER ALL EXCAVATION,
BACKFILLING AND COMPACTION IS COMPLETE.
R320.1.2 IF SOIL TREATMENT IS USED FOR SUBTERRANEAN TERMITE PREVENTION, SOIL AREA DISTURBED
AFTER INITIAL CHEMICAL SOIL TREATMENT SHALL BE RETREATED WITH A CHEMICAL SOIL TREATMENT,
INCLUDING SPACES BOXED OR FORMED.
R320.1.3 IF SOIL TREATMENT IS USED FOR SUBTERRANEAN TERMITE PREVENTION, SPACE IN CONCRETE
FLOORS BOXED OUT OR FORMED FOR THE SUBSEQUENT INSTALLATION OF PLUMBING TRAPS, DRAINS OR
ANY OTHER PURPOSE SHALL BE CREATED BY USING PLASTIC OR METAL PERMANENTLY PLACED FORMS
OF SUFFICIENT DEPTH TO ELIMINATE ANY PLANNED SOIL DISTURBANCE AFTER INITIAL CHEMICAL SOIL
TREATMENT.
R320.1.4 IF SOIL TREATMENT IS USED FOR SUBTERRANEAN TERMITE PREVENTION, CHEMICALLY TREATED
SOIL SHALL BE PROTECTED WITH A MINIMUM 6 MIL VAPOR RETARDER TO PROTECT AGAINST RAINFALL
DILUTION. IF RAINFALL OCCURS BEFORE VAPOR RETARDER PLACEMENT, RETREATMENT IS REQUIRED.
ANY WORK, INCLUDING PLACEMENT OF REINFORCING STEEL, DONE AFTER CHEMICAL TREATMENT UNTIL
THE CONCRETE FLOOR IS POURED, SHALL BE DONE IN SUCH MANNER AS TO AVOID PENETRATING OR
DISTURBING TREATED SOIL.
R320.1.5 IF SOIL TREATMENT IS USED FOR SUBTERRANEAN TERMITE PREVENTION, CONCRETE OVERPOUR
OR MORTAR ACCUMULATED ALONG THE EXTERIOR FOUNDATION PERIMETER SHALL BE REMOVED PRIOR
TO EXTERIOR CHEMICAL SOIL TREATMENT, TO ENHANCE VERTICAL PENETRATION OF THE CHEMICALS.
R320.1.6 IF SOIL TREATMENT IS USED FOR SUBTERRANEAN TERMITE PREVENTION, CHEMICAL SOIL
TREATMENTS SHALL ALSO BE APPLIED UNDER ALL EXTERIOR CONCRETE OR GRADE WITHi N 1 FOOT (305
MM) OF THE PRIMARY STRUCTURE SIDEWALLS. ALSO, A VERTICAL CHEMICAL BARRIER SHALL BE APPLIED
PROMPTLY AFTER CONSTRUCTION IS COMPLETED, INCLUDING INITIAL LANDSCAPING AND
IRRIGATION/SPRINKLER INSTALLATION. ANY SOIL DISTURBED AFTER THE CHEMICAL VERTICAL BARRIER IS
APPLIED SHALL BE PROMPTLY RETREATED.
R320.1.7 IF A REGISTERED TERMITICIDE FORMULATED AND REGISTERED AS A BAIT SYSTEM IS USED FOR
SUBTERRANEAN TERMITE PREVENTION, SECTIONS
R320.1.1 THROUGH R320.1.6 DO NOT APPLY; HOWEVER, A SIGNED CONTRACT ASSURING THE
INSTALLATION, MAINTENANCE AND MONITORING OF THE BAITING SYSTEM FOR A MINIMUM OF FIVE YEARS
FROM THE ISSUE OF THE CERTIFICATE OF OCCUPANCY SHALL BE PROVIDED TO THE BUILDING OFFICIAL
PRIOR TO THE POURING OF THE SLAB, AND THE SYSTEM MUST BE INSTALLED PRIOR TO FINAL BUILDING
APPROVAL. IF THE BAITING SYSTEM DIRECTIONS FOR USE REQUIRE A MONITORING PHASE PRIOR TO
INSTALLATION OF THE PESTICIDE ACTIVE INGREDIENT, THE INSTALLATION OF THE MONITC-'.ING PHASE
COMPONENTS SHALL BE DEEMED TO CONSTITUTE INSTALLATION OF THE SYSTEM.
R320.1.8 IF A REGISTERED TERMITICIDE FORMULATED AND REGISTERED AS A WOOD TREATMENT IS USED
FOR SUBTERRANEAN TERMITE PREVENTION, SECTIONS R320.1.1 THROUGH R320.1.6 DO NOT APPLY.
APPLICATION OF THE WOOD TREATMENT TERMITICIDE SHALL BE AS REQUIRED BY LABEL DIRECTIONS FOR
USE, AND MUST BE COMPLETED PRIOR TO FINAL BUILDING APPROVAL.
R320.2 PENETRATION.
PROTECTIVE SLEEVES AROUND METALLIC PIPING PENETRATING CONCRETE SLAB -ON -GRADE FLOORS
SHALL NOT BE OF CELLULOSE -CONTAINING MATERIALS AND, IF SOIL TREATMENT IS USED FOR
SUBTERRANEAN TERMITE PROTECTION, SHALL RECEIVE APPLICATION OF A TERMITICIDE IN ANNULAR
SPACE BETWEEN SLEEVE AND PIPE.
R320.3 CLEANING.
CELLS AND CAVITIES IN MASONRY UNITS AND AIR GAPS BETWEEN BRICK, STONE OR MASONRY VENEERS
AND THE STRUCTURE SHALL BE CLEANED OF ALL NONPRESERVATIVE TREATED OR NONNATURALLY
DURABLE WOOD, OR OTHER CELLULOSE -CONTAINING MATERIAL PRIOR TO CONCRETE PLACEMENT.
EXCEPTION: INORGANIC MATERIAL MANUFACTURED FOR CLOSING CELLS IN FOUNDATION CONCRETE
MASONRY UNIT CONSTRUCTION OR CLEAN EARTH FILL PLACED IN CONCRETE MASONRY UNIT VOIDS
BELOW SLAB LEVEL BEFORE TERMITE TREATMENT IS PERFORMED.
R320.4 CONCRETE BEARING LEDGE.
BRICK, STONE OR OTHER VENEER SHALL BE SUPPORTED BY A CONCRETE BEARING LEDGE OF SUCH
THICKNESS AS REQUIRED IN CHAPTER 14, WHICH IS POURED INTEGRALLY WITH THE CONCRETE
FOUNDATION. NO SUPPLEMENTAL CONCRETE FOUNDATION POURS WHICH WILL CREATE A HIDDEN COLD
JOINT SHALL BE USED WITHOUT SUPPLEMENTAL TREATMENT IN THE FOUNDATION UNLESS THERE IS AN
APPROVED PHYSICAL BARRIER. AN APPROVED PHYSICAL BARRIER SHALL ALSO BE INSTALLED FROM
BELOW THE WALL SILL PLATE OR FIRST BLOCK COURSE HORIZONTALLY TO EMBED IN A MORTAR JOINT. IF
MASONRY VENEER EXTENDS BELOW GRADE, A TERMITE PROTECTIVE TREATMENT MUST BE APPLIED TO
THE CAVITY CREATED BETWEEN THE VENEER AND THE FOUNDATION, IN LIEU OF A PHYSICAL BARRIER.
EXCEPTION: VENEER SUPPORTED BY A STRUCTURAL MEMBER SECURED TO THE FOUNDATION SIDEWALL
AS PROVIDED IN SECTION 1403, PROVIDED AT LEAST A 6-INCH (152 MM) CLEAR INSPECTION SPACE OF THE
FOUNDATION SIDEWALL EXTERIOR EXIST BETWEEN THE VENEER AND THE TOP OF ANY SOIL, SOD, MULCH
OR OTHER ORGANIC LANDSCAPING COMPONENT, DECK, APRON, PORCH, WALK OR ANY OTHER WORK
IMMEDIATELY ADJACENT TO OR ADJOINING THE STRUCTURE.
R320.5 PRESSURE PRESERVATIVELY TREATED AND NATURALLY RESISTANT WOOD.
HEARTWOOD OF REDWOOD AND EASTERN RED CEDAR, AND PRESSURE PRESERVATIVE TREATED WOOD
IN ACCORDANCE WITH THE AWPA STANDARD LISTED IN SECTION R319.1 SHALL BE CONSIDERED TERMITE
RESISTANT. PRESSURE PRESERVATIVELY TREATED WOOD AND NATURALLY TERMITE -RESISTANT WOOD
SHALL NOT BE USED AS A PHYSICAL BARRIER UNLESS A BARRIER CAN BE INSPECTED FOR ANY TERMITE
SHELTER TUBES AROUND THE INSIDE AND OUTSIDE EDGES AND JOINTS OF A BARRIER.
R320.5.1 QUALITY MARK.
LUMBER AND PLYWOOD REQUIRED TO BE PRESSURE PRESERVATIVE TREATED IN ACCORDANCE WITH
SECTION R320.1 SHALL BEAR THE QUALITY MARK OF AN APPROVED INSPECTION AGENCY WHICH
MAINTAINS CONTINUING SUPERVISION, TESTING AND INSPECTION OVER THE QUALITY OF THE PRODUCT
AND WHICH HAS BEEN APPROVED BY AN ACCREDITATION BODY WHICH COMPLIES WITH THE
REQUIRMENTS OF THE AMERICAN LUMBER STANDARD COMMITTEE TREATED WOOD PROGRAM.
R320.5.2 FIELD TREATMENT
FIELD CUT ENDS, NOTCHES AND DRILLED HOLES OF PRESSURE PRESERVATIVELY TREATED WOOD SHALL
BE RETREATED IN THE FIELD IN ACCORDANCE WITH AWPA M4.
R320.6 FOAM PLASTIC PROTECTION.
EXTRUDED AND EXPANDED POLYSTYRENE, POLYI SOCYAN U RATE AND OTHER FOAM PLASTICS SHALL NOT
BE INSTALLED ON THE EXTERIOR FACE OR UNDER INTERIOR OR EXTERIOR FOUNDATION WALLS OR SLAB
FOUNDATIONS LOCATED BELOW GRADE. THE CLEARANCE BETWEEN FOAM PLASTICS INSTALLED ABOVE
GRADE AND EXPOSED EARTH SHALL BE AT LEAST 6 INCHES (152 MM).
EXCEPTIONS:
1. BUILDINGS WHERE THE STRUCTURAL MEMBERS OF WALLS, FLOORS, CEILINGS AND ROOFS ARE
ENTIRELY OF NONCOMBUSTIBLE MATERIALS OR PRESSURE PRESERVATIVELY TREATED WOOD.
2. WHEN IN ADDITION TO THE REQUIREMENTS OF SECTION R320.1, AN APPROVED METHOD OF
PROTECTING THE FOAM PLASTIC AND STRUCTURE FROM SUBTERRANEAN TERMITE DAMAGE IS USED.
3. ON THE INTERIOR SIDE OF BASEMENT WALLS.
FLORIDA BUILDING CODE REQUIREMENTS
1. GENERAL REQUIREMENTS
1.A. CODES:
1.A.1. BEFORE FINAL DRAWINGS AND SPECIFICATIONS ARE ISSUED FOR CONSTRUCTION, THEY SHALL BE
SUBMITTED TO ALL GOVERNING AGENCIES TO INSURE THEIR COMPLIANCE WITH ALL APPLICABLE
LOCAL AND NATIONAL CODES.
1.A.2. IF CODE DISCREPANCIES ARE DISCOVERED DURING THE CONSTRUCTION PROCESS, THE
ARCHITECT SHALL BE NOTIFIED AND ALLOWED AMPLE TIME TO REMEDY SAID DISCREPANCIES.
1.6. ALL CONTRACTORS, SUBCONTRACTORS, SUPPLIERS AND FABRICATORS SHALL BE RESPONSIBLE FOR
THE CONTENT OF DRAWINGS, AND FOR THE SUPPLY AND DESIGN OF APPROPRIATE MATERIALS AND
WORK PERFORMANCE.
1.C. ALL MANUFACTURED ARTICLES, MATERIALS AND EQUIPMENT SHALL BE APPLIED, INSTALLED, ERECTED,
USED, CLEANED, AND CONDITIONED IN STRICT ACCORDANCE WITH MANUFACTURER'S
RECOMMENDATIONS.
1.13. ALL ALTERNATES ARE AT THE OPTION OF THE OWNER AND SHALL BE AT THE BUILDERS REQUEST,
CONSTRUCTED IN ADDITION TO OR IN LIEU OF THE TYPICAL CONSTRUCTION,AS INDICATED ON
DRAWINGS.
1.E. DESIGN LOADS:.
1.E.1. ROOF: LIVE LOAD ....... 20 PSF(MINIMUM). DEAD LOAD ..... 20 PSF(SHINGLE).
DEAD LOAD ..... 30 PSF(TILE)
1.E.2. FLOOR: LIVE LOAD ....... 40 PSF(MINIMUM). DEAD LOAD ..... 10 PSF
1.E.3. EXTERIOR BALCONIES: LIVE LOAD ....... 60 PSF DEAD LOAD ..... 10 PSF
1.E.4. GUARDRAILS & HANDRAILS: ........................ 20OPSF
1.E.5. SOIL PRESSURE: ........................................... 2000 PSF (ASSUMED MIN.).
2. SITEWORK
2.A. PERFORM EXCAVATION, ACCORDING TO GOOD COMMON CONSTRUCTION PRACTICES, TO THE LINES,
GRADES AND ELEVATIONS INDICATED ON THE DRAWINGS.
2.13. PROVIDE CONSISTENT COMPACTION OF THE TOP 8" OF SUBGRADE, FILL AND BACKFILL MATERIAL
BENEATH STRUCTURES, WALKS AND PAVEMENTS TO MEET THE STATED SOIL PRESSURE. COMPACTION
TEST SHALL BE PERFORMED.
2.C. PROVIDE BORA CARE SOIL TREATMENT FOR TERMITES AS REQUIRED.
3. CONCRETE
3.A. PROVIDE REINFORCEMENT OF THE SIZE AND SPACING SHOWN ON DRAWINGS. STEEL REINFORCING
SHALL COMPLY WITH THE FOLLOWING CRITERIA:
3.A.1. BARS.................ASTM A615, GRADE 60, DEFORMED BARS.
3.A.2. WELDED WIRE FABRIC ... ASTM A185.
3.13. PROVIDE CONCRETE COMPLYING WITH ASTM C94. CONCRETE SHALL HAVE THE FOLLOWING 28 DAY
MINIMUM COMPRESSIVE STRENGTHS:
3.13.1. CONCRETE FOOTINGS AND PIERS.............3000 PSI
3.13.2. CONCRETE HEADERS AND TIE BEAMS .......... 3000 PSI
3.13.3. CONCRETE SLABS ON GRADE.................3000 PSI
3.C. UNLESS OTHERWISE NOTED, ALL SLABS ON GRADE SHALL BE 3 1/2" THICK, REINFORCED WITH
6X6-W1.4/W1.4 WWM OR FIBERMESH AND PLACED OVER 4" MIN. COMPACTED FILL. ALL INTERIOR SLABS
SHALL BE OVER .006 POLYETHYLENE MOISTURE BARRIER.
3.D. FOOTING SIZES SHOWN ARE TYPICAL ONLY FOR STATED SOIL BEARING PRESSURE AND CONSISTED
COMPACTION. CONTRACTOR SHALL BE RESPONSIBLE FOR FOOTINGS COMPLYING WITH THE DESIGN
REQUIREMENTS OF SPECIFIC SOIL CONDITIONS.
3.E. PROVIDE 1/2" EXPANSION JOINT MATERIAL BETWEEN ALL CONCRETE SLABS AND ABUTTING CONCRETE
OR MASONRY WALLS OCCURRING IN EXTERIOR OR UNHEATED AREAS.
4. MASONRY
4.A. PROVIDE LIGHTWEIGHT HOLLOW 8" LOAD -BEARING CONCRETE MASONRY UNITS (CMU) COMPLYING
WITH ASTM C90, 1900 PSI, GRADE N, TYPE L.
4.8. STEEL REINFORCEMENT SHALL COMPLY WITH THE FOLLOWING:
4.6.1. BARS...................ASTM A615, GRADE 60, FORMED BARS.
4.6.2. WIRE JOINT REINF....... ASTM A82, GALVANIZEDZ
4.6.3. FOOTING DOWELS ......ASTM A615, GRADE 60, DEFORMED BARS WITH 90 DEGREE HOOK, 10"LONG #5
& 14"LONG FOR #7, WITH 6" MINIMUM EMBEDMENT AND 25" LAP #5, 35" LAP #7 AT:
4.13.3.1. BUILDING CORNERS.
4.13.3.2. EACH SIDE OF OPENINGS.
4.B.3.3. ENDS OF EACH SHEAR WALL SEGMENT.
4.B.3.4. ALL OTHER FILLED CELLS WITH VERTICAL REINFORCING.
4.C. PROVIDE MORTAR TYPE "S" IN ACCORDANCE WITH ASTM C270.
4.D. PROVIDE GROUT IN ACCORDANCE WITH ASTM C476. MINIMUM COMPRESSIVE STRENGTH SHALL BE 3000
PSI UNLESS OTHERWISE NOTED.
4.E. ALL ANCHOR BOLTS SHALL BE 1/2"D.X8"L. WITH 2" BEND AND 2" WASHERS, SPACING SHALL BE AS NOTED.
4.F. WIRE JOINT REINFORCEMENT SHALL BE CONTINUOUS AND EMBEDDED IN EVERY 3RD CMU COURSE.
(THIS ONLY APPLIES TO UNSUPPORTED WALLS.)
4.G. MASONRY LINTELS SHALL BEAR MINIMUM 4" ON EITHER SIDE OF OPENING.
4.H. BOND BEAMS OR TIE BEAMS SHALL BE PROVIDED AT THE TOP OF EACH FLOOR LEVEL OF EXTERIOR
MASONRY WALLS.
5. M ETALS
5.A. ALL STRUCTURAL STEEL SHALL COMPLY WITH APPROPRIATE ASTM SPECIFICATIONS AS FOLLOWS: ASTM
A36, ASTM A53, ASTM A501, ASTM A307 AND ASTM A325.
6. WOOD AND PLASTICS
6.A. LUMBER SHALL COMPLY WITH:
6.A.1. "PRODUCT USE MANUAL" OF THE WESTERN WOOD PRODUCTS ASSOCIATION FOR SELECTION
AND USE OF PRODUCTS INCLUDED IN THAT MANUAL.
6.A.2. "PLYWOOD SPECIFICATION AND GRADE GUIDE" OF THE AMERICAN PLYWOOD ASSOCIATION.
6.A.3. AMERICAN WOOD PRESERVERS ASSOCIATION STANDARDS AND RECOMMENDATIONS FOR FIRE
RETARDATE AND PRESERVATIVE PRESSURE TREATED LUMBER AND PLYWOOD.
6.6. PROVIDE LUMBER MEETING OR EXCEEDING THE FOLLOWING REQUIREMENTS:
6.6.1. FRAMING MEMBERS:
6.B.1.1. STUDS..................HEM-FIR, 19% SELECT STRUCTURAL
6.13.1.2. HEADERS AND BEAMS...... SOUTHERN PINE 2D KD AND BETTER.
6.13.2. ALLOWABLE STRESSES:
6.13.2.1. WOOD STUDS
6.6.2.1.1. BENDING............................1200 PSI (SINGLE)
6.13.2.1.2. HORIZONTAL SHEAR ........ 85 PSI
6.6.2.1.3. BEARING ............................405 PSI
6.6.2.1.4. COMPRESSION .................1000 PSI
6.13.2.1. WOOD HEADERS AND BEAMS
6.6.2.1.1. BENDING............................1550 PSI
6.13.2.1.1. HORIZONTAL SHEAR ........ 95 PSI
6.6.2.1.1. BEARING ............................660 PSI
6.6.2.1.1. COMPRESSION .................1400 PSI
6.13.3. ALL HEADERS AND BEAMS SHALL BE FREE OF SPLITS, CHECKS AND SHAKES. ALL HEADERS
SHALL BE (2)2X12 W/ 1/2" PLYWOOD AND 3 ROWS OF 10d NAILS AT 12"O.C.
6.13.4. SHEATHING:
6.13.4.1. ROOF............ 1/2" APA RATED 4 PLY PLYWOOD SHEATHING, NAILED W/ 8d RING SHANKS AT
4" O.C. (EDGE 6" O.C. (FIELD)
6.13.4.2. FLOORS ........... 3/4" T&G PLYWD GLUED & NAILED W/ 8d RING SHANK NAILS AT 6" O.C. AT
EDGE & 12" O.C. IN FIELD.
6.13.4.3. WALLS..............1/2" APA RATED 3 PLY PLYWOOD SHEATHING, NAILED W/ 8d COMMONS AT 4"
O.C. (EDGE), 6" O.C. (FIELD)
6.13.5. ROUGH HARDWARE AND CONNECTIONS:
6.13.5.1. STEEL ITEMS WILL BE BY SIMPSON STRONG TIE OR EQUAL, AND COMPLY WITH ASTM A7 OR
ASTM A36; USE GALVANIZED STEEL AT EXTERIOR LOCATIONS.
6.6.5.2. INSTALL JOIST OR BEAM HANGERS CAPABLE OF CARRYING THE MAXIMUM ALLOWABLE
LOAD OF JOIST OR BEAM BEING SUPPORTED:
6.6.5.3. INSTALL UPLIFT CONNECTORS AND HURRICANE TIE DOWNS AS NOTED ON DRAWINGS.
6.13.5.4. HURRICANE ANCHORING SHALL BE INSTALLED FROM FOUNDATION THROUGH ROOF.
6.C. PROVIDE WOOD TRUSSES ABLE TO SUSTAIN THE STATED LOADS FOR THE SPANS, TRUSS LAYOUT
IS SCHEMATIC ONLY. TRUSS MANUFACTURER AND/OR ENGINEER SHALL BE RESPONSIBLE FOR THE
DESIGN AND SPACING OF ALL TRUSSES AND SHALL SUBMIT SHOP DRAWINGS TO THE BUILDER AND
ARCHITECT FOR APPROVAL.
6.D. ALL WOOD PLATES BEARING ON, OR COMING IN CONTACT WITH, CONCRETE OR MASONRY SHALL BE
PRESSURE TREATED AND INSTALLED OVER 6 MIL POLYETHYLENE MOISTURE BARRIER.
6.E. PROVIDE 2" NOMINAL PRESSURE TREATED LUMBER OVER 6 MIL POLYETHYLENE MOISTURE
BARRIER BENEATH FULL BEARING OF WOOD BEAMS ON CONCRETE OR MASONRY. "X" BRACING
SHALL BE PROVIDED AT 4'-0" O.C. FIRST THREE FRAMING SPACES EACH END OF GABLE OR
GALVANIZED SEAT PLATE
7. DOORS AND WINDOWS
TA. PROVIDE DOORS AND SIDELITES OF THE SIZE, TYPE AND DESIGN ON THE DRAWINGS.
7.6. PROVIDE TEMPERED GLASS AT ALL HAZARDOUS LOCATIONS.
7.6.1. SLIDING GLASS DOORS SHALL BE SELECTED BY OWNER.
7.B.1.1. GLAZING SHALL BE SINGLE -PANE TEMPERED GLASS.
7.13.2. BUILDING DESIGNED TO BE ENCLOSED. PROTECTIVE SHUTTERS OR IMPACT RESISTANT
WINDOWS PREFERED.
8. FINISHES
8.A. GYPSUM WALLBOARD SHALL BE PROVIDED AS FOLLOWS:
8.A.1. INTERIOR PARTITIONS: ONE LAYER 1/2" REGULAR WALLBOARD EACH SIDE.
8.A.2. CEILING:
8.A.2.1. ONE LAYER 5/8" REGULAR WALLBOARD OR 1/2" DENSE CEILING BOARD WHEN SUPPORTING
MEMBERS ARE GREATER THAN 16" O.C.
8.A.2.2. ONE LAYER 1/2" WALLBOARD WHEN SUPPORTING MEMBERS ARE 16" O.C. OR LESS.
8.A.2.3. ONE LAYER 1/2" CEMENT BACKER BOARD BEHIND TILE WALLS FOR TUBS & SHOWERS
8.13. PROVIDE METAL CORNER BEAD AND TRIM AS RECOMMENDED BY GYPSUM WALLBOARD
MANUFACTURER.
8.C. TAPE, SAND AND FLOAT JOINTS AND FASTENERS OF GYPSUM WALLBOARD WITH THREE COATS OF
JOINT COMPOUND AS REQUIRED TO OBTAIN A UNIFORMLY SMOOTH SURFACE.
B.D. FINISHES SHOWN ON DRAWINGS SHALL BE SELECTED BY OWNER.
9. ROOF COVERING
9.A. ROOF COVERINGS SHALL BE PEEL AND STICK APPLIED IN ACCORDANCE WITH THE APPLICABLE
PROVISIONS OF FBC SECTION 1507 AND THE MANUFACTURER'S INSTALLATION INSTRUCTIONS.
10. MISCELLANEOUS
10.A. DO NOT SCALE DRAWINGS; WHERE DISCREPANCIES BETWEEN DIMENSIONS AND SCALE OCCUR,
DIMENSIONS
_ -I GENERAL STRUCTURAL SPECIFICATIONS FOR ENCLOSED STRUCTURES
1. WINDOW AND DOOR ASSEMBLIES SHALL BE ANCHORED IN ACCORDANCE WITH THE PUBLISHED MANUFACTURER'S RECOMMENDATIONS TO ACHIEVE THE DESIGN PRESSURE SPECIFIED. SUBSTITUTE ANCHORING SYSTEMS
USED FOR SUBSTRATES NOT SPECIFIED BY THE FENESTRATION MANUFACTURER SHALL PROVIDE EQUAL OR GREATER ANCHORING PERFORMANCE AS DEMONSTRATED BY ACCEPTED ENGINEERING PRACTICE.
2. WHERE THE WOOD SHIM OR BUCK THICKNESS IS LESS THAN 1-1/2 INCHES, WINDOW AND DOOR ASSEMBLIES SHALL BE ANCHORED THROUGH THE MAIN FRAME OR BY JAMB CLIP OR SUBFRAME SYSTEM, IN ACCORDANCE
WITH THE MANUFACTURERS PUBLISHED INSTALLATION INSTRUCTIONS. ANCHORS SHALL BE SECURELY FASTENED DIRECTLY INTO THE MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE MATERIAL. UNLESS
OTHERWISE TESTED, BUCKS SHALL EXTEND BEYOND THE INTERIOR FACE OF THE WINDOW OR DOOR FRAME SUCH THAT FULL SUPPORT OF THE FRAME IS PROVIDED. SHIMS SHALL BE MADE FROM MATERIALS CAPABLE OF
SUSTAINING APPLICABLE LOADS. ANCHORS SALL BE PROVIDED TO TRANSFER LOAD FROM WINDOW OR DOOR FRAME TO THE ROUGH OPEING SUBSTRATE.
3. WHERE THE WOOD BUCK THICKNESS IS 1-1/2 INCHES OR GREATER, THE BUCK SHALL BE SECURELY FASTENED TO TRANSFER LOAD TO THE MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE AND THE BUCK
SHALL EXTEND BEYOND THE INTERIOR FACE OF THE WINDOW OR DOOR FRAME. WINDOW AND DOOR ASSEMBLIES SHALL BE ANCHORED THROUGH THE MAIN FRAME OR BY JAMB CLIP OR SUBFRAME SYSTEM OR THROUGH
THE FLANGE TO THE SECURED WOOD BUCK IN ACCORDANCE WITH THE MANUFACTURERS PUBLISHED INSTALLATION INSTRUCTIONS. UNLESS OTHERWISE TESTED, BUCKS SHALL EXTEND BEYOND THE INTERIOR FACE OF
THE WINDOW OR DOOR FRAME SUCH THAT FULL SUPPORT OF THE FRAME IS PROVIDED. SHIMS SHALL BE MADE FROM MATERIALS CAPABLE OF SUSTAINING APPLICABLE LOADS, LOCATED AND APPLIED THICKNESS CAPABLE
OF SUSTAINING APPLICABLE LOADS. ANCHORS SHALL BE PROVIDED TO TRANSFER LOAD FROM THE WINDOW OR DOOR FRAME ASSEMBLY TO THE SECURED WOOD BUCK.
4. WHERE THE FRAMING MATERIAL IS WOOD OR OTHER APPROVED FRAMING MATERIAL, WINDOW AND GLASS DOOR ASSEMBLIES SHALL BE ANCHORED THROUGH THE MAIN FRAME OR BY JAMB CLIP OR SUBFRAME SYSTEM
OR THROUGH THE FLANGE IN ACCORDANCE WITH THE MANUFACTURER'S PBLISHED INSTALATION INSTRUCTIONS. SHIMS SHALL BE MADE FROM MATERIALS CAPABLE OF SUSTAINING APPLICABLE LOADS, LOCATED AND
APPLIED THICKNESS CAPABLE OF SUSTAINING APPLICABLE LOADS. ANCHORS SHALL BE PROVIDED TO TRANSFER LOAD FROM THE WINDOW OR DOOR FRAME TO THE ROUGH OPENING SUBSTRATE.
5. IF A GAP BETWEEN FRAME AND WALL IS LARGER THAN THE BUCK, THEN SHIMMING IS REQUIRED. SHIMMING SHALL BE DONE BY PLACING 1/4" P.T. PLYWOOD STRIPS BETWEEN THE FRAME AND THE BUCK. THE SHIMS SHALL
BE ATTACHED TOGETHER WITH THE BUCK TO HAVE IT AS ONE PIECE. HIGHER GAPS SHALL BE FILLED WITH ADDITIONAL 1X OR 2X BUCKS, ALL ATTACHED WITH MINIMUM #8 SCREWS.
_ A WINDOW & DOOR ASSEMBLIES ANCHORING REQ.
PRODUCT CATEGORY
SUB CATEGORY
MANUFACTURER
STATE OF FLORIDAAPPROVAL NUMBER
WINDOWS
SINGLE HUNG
CUSTOM WINDOW SYSTEMS, INC.
FL 5823
EXTERIOR DOORS
EXTERIOR INSWING/OUTSWING DOOR
THERMA-TRU CORPORATION
FL7347.1
EXTERIOR DOORS
SECTIONAL
OVERHEAD
FL8822.2
ROOFING
SHINGLE ROOF
GAF MATERIAL CORP
NOA 06-1211.02
STRUCTURAL COMPONENTS
ENGINEERED LUMBER
TRUSS JOIST, A WEYERHAEUSER BUSINESS
FL1630.2
STRUCTURAL COMPONENTS
ENGINEERED LUMBER
BOISE ENGINEERED WOOD PRODUCTS
FL1644.1
STRUCTURAL COMPONENTS
ENGINEERED LUMBER
GEORGIA-PACIFIC CORPORATION
FL2023.1
STRUCTURAL COMPONENTS
CONCRETE/PRESTRESSED LINTELS
FECP CORP., CAST-CRETE DIVISION
FL158.1
STRUCTURAL COMPONENTS
WOOD/MASONRY CONNECTORS
A34, ABU66, ECC, H6,HETA20,HTS30, HUC210,
HUS26,MSTA24, MST16, MST20, MGT, SP1, SS1,SS3
SIMPSON STRONG -TIE CO.
FL474.4, FL5808.1, FL5805.9, FL5805.28, FL474.59, FL474.68,
FL474.96, FL5808.150, FL3750.81, FL3750.82, FL474.188,
FL474.192, FL474.246, FL1423.15, FL474.281, FL474.312,
FL474.313
DESIGN PRESSURES - 130 MPH BASIC WIND SPEED - EXPOSURE C
Wind Velocity (mph) 130
Building Category II
Importance Factor 1
Exposure Category C
Internal Pressure Coefficient + 0.18
ENCLOSED
IMPACT RESISTANT WINDOWS
AND DOORS ARE REQUIRED
BASED ON THE FLORIDA BUILDING CODE 2007, RESIDENTIAL, SECTION R301.2
COMPONENT & CLADDING DESIGN PRESSURES (PSF) - 130 MPH BASIC WIND SPEED
DESCRIPTION 1 2 3 4 5
ROOF & WALL COMPONENTS &
CLADDING (INCLUDING WINDOWS 42.6 -82.2 -82.2 -39.93 49.25
AND DOORS)
GARAGE DOORS
- 1 -34.49
MAIN WIND FORCE RESISTING SYSTEM WIND LOADS
HORIZONTAL LOADS
LOAD DIRECTION
END ZONE
WALL
ROOF
TRANSVERSE
60.2
33.5
LONGITUDINAL
43.5
-22.5
VERTICAL LOADS
LOAD DIRECTION
END ZONE
WINDWARD ROOF
LEEWARD ROOF
TRANSVERSE
-52.2
-36.4
LONGITUDINAL
-52.2
-29.7
VERTICAL LOADS
WINDWARD OVERHANG
LOAD DIRECTION
END ZONE INTERIOR ZONE
TRANSVERSE -72.2 -57.3
LONGITUDINAL -73.2 -57.3
ROO
ANG
ON6`�
V
INTERIOR ZONE
WALL ROOF
40.2 26.7
28.8 -13.4
INTERIOR ZONE
WINDWARD LEEWARD
ROOF ROOF
-36.4 -27.6
-36.4 -23.0
MAXIMUM HORIZONTAL LOADS
ZONE
1E
4E
1
4
40.6
-34.3
30.9
-25.5
33.6
-25.5
24.2
-19.6
<:/ WIND DIRECTION1�
RANGE
=
c4
0
~
u
Q 0
N
z
�0=
FH
Uj
ow 0
z
U)oE
~ N U
w
ui
J
w=Q
�
O
wow
Iwo
WUF0
w
M
0
Ld
LL
=00
1
�Zz
Imo
0�
U��?
�Z
m~Quj
<a
MZM_j wpouj
Ow
cl)Z
wD0a
O
LL U)
H fn
of
N
0
L.L
. 0
->
0
^�
CU
E
M
U
M
�
_..I
L_
O
(1)
O-L
o0Cl)M
^�
W
Q
N
Q
4-0
W
Q
E
O
._
CD
U
s_
CL
C*
Cn
M
C:
O
�
U
>
p
(1)
U
W
0
CU
Mw
mMOM
M,
ISSUE DATE: 05/06/10
JOB CAPTAIN: JMG
SCALE: AS NOTED
CHECKED BY: JMG/PF
PROJECT NUMBER: 0737
STRUCTURAL
DETAILS 1
S1
J
PRE-ENGINEERED WD. TRUSSES AT 24"
O.C. MAX. W/ GALV. MTL. SEAT PLATES
SLOPE
PER 1/2" PLYWD SHEATHING NAILED W/ 8d RING SHANKS
ELEV. AT 4" O.C. (EDGE), 6" O.C. (FIELD) W/ GALV. CLIPS
ROOF FINISH PER ELEVATION
/ SIMPSON
TA20 AT EACH TRUSS U.N.O. -
SEE FRAMING
R-30 INSULATION MIN
ELEV AT 8'-0"
FIRST FLR CLG
1/2" CEILING BOARD CLG.
1X3 FURRING STRIP
1/2" DRYWALL, TYP. U.N.O
1X2 FURRING
STRIPS AT 24" O.C.
(R-5) 3/4" INSULATION BOARD
1X3 P.T. FURRING STRIPS ----
4" THICK CONC. SLAB W/6"X6" W1.4 X
W1.4 WIRE MESH OVER .006
POLYETHYLENE VAPOR BARRIER.
HOLD MESH IN TOP 1 1/2" OF SLAB. _
BASE TRIM PER SPECS —�
ELEV AT 0'-0"
1ST FLOOR FF °
� a
°
oa °
NOTE: REFER TO ELEVATION
SHEET FOR SOFFIT AND
FASCIA DETAILS
PER
ELEV.
(1) COURSE 8 X 8 KNOCK- OUT BLK
FILLED SOLID W/ (1) #5 BAR TYP.
STD. 90° HOOK W/
10" MIN. OVERLAP
(1) #5 BAR VERTICAL IN FILLED CELL
TYP. SEE FLOOR PLAN AND
FOUNDATION PLAN FOR SPACING.
DECORATIVE CEMENITIOUS COATING
TYP. U.N.O. AT EXT. MASONRY
WALLS. SEE ELEVATION SHEET FOR
TEXTURES
25" MIN LAP
8 X 8 X 16 C.M.U. TYP.
4" X 4" INSPECTION PORT AT
EACH FILLED CELL (TYP.)
SIZE & SPACING OF DOWN BARS
TO MATCH VERTICAL BARS WITH
25" MIN. LAP W/ VERT. REINFG
EXTEND PARGE COAT 4"
BELOW GRADE TYP.
GRADE
= z
a0 g
AV
0
CLEAN POISONED
AND COMP. SOIL
(2) #5 BARS CONT STANDARD 90° HOOK SEE
REBAR DETAIL
1 TYPICAL WALL SECTION AT FILLED CELL ONE STORY
3/411— 11-011
PRE-ENGINEERED WD. TRUSSES AT 24"
O.C. MAX. W/ GALV. MTL. SEAT PLATES
SLOPE
PER 1/2" PLYWD SHEATHING NAILED W/ 8d RING SHANKS
ELEV. AT 4" O.C. (EDGE), 6" O.C. (FIELD) W/ GALV. CLIPS
ROOF FINISH PER ELEVATION
SIMPSON HHETA20 AT EACH TRUSS U.N.O. -
SEE FRAMING R-30 INSULATION MIN
R-30 INSULATION MIN
NOTE: REFER TO ELEVATION
ELEV AT 8'-0" SHEET FOR SOFFIT AND VARIES
FASCIA DETAILS
FIRST FLR CLG SEE FLOOR PLAN -
1/2" CEILING BOARD CLG. •• PER 1J2" CEILING
ELEV.
WINDOWS ELEV 6'-8" BOARD CLG. -
WINDOW HEAD HEIGHT -
(1) COURSE 8 X 8 KNOCK- OUT BLK
1X3 FURRING STRIP FILLED SOLID W/ (1) #5 BAR TYP.
1X6, 20" BEYOND EACH 1/2" DRYWALL, TYP. U.N.O.
SIDE OF OPENING. 8 X 8 PRE CAST CONCRETE "U" LINTEL
FILLED PER CALL OUT ON FLOOR PLAN
P.T. BUCK GLUED AND NAILED 3 SIDES. 2X STUDS AT 16" O.C.
USE .097 DIA X 1 3/8" "T" NAILS AT 8" O.C. WINDOW PER SPECS (STUD WIDTH MAY -
P.T. BUCK TO BE NO MORE THAN 1" THICK ; (SINGLE HUNG SHOWN) VARY SEE PLANS) -
SILL (SEE SPECS) j CAULK ENTIRE UNIT PER -
1X4 AT JAMBS & SILL MANUFACTURER SPECS
INTERIOR
1/2" DRYWALL, TYP. U.N.O. FLUSH PRECAST
CONCRETE SILL
1X2 FURRING DECORATIVE CEMENITIOUS COATING
STRIPS AT 24" O.C. TYP. U.N.O. AT EXT. MASONRY
WALLS. SEE ELEVATION SHEET FOR (R-11) BATT INSULATION
(R-5) 3/4" INSULATION BOARD TEXTURES 5/8" X 10" A.B. W/ 2" X
1X3 P.T. FURRING STRIPS 2" X 1/8" STEEL
WASHERS AT 36" O.C. -
4" THICK CONC. SLAB W/6"X6" W1.4 X OR 5/8" X 8" SIMPSON -
W1.4 WIRE MESH OVER .006 8 X 8 X 16 C.M.U. TYP. TITEN HD OR EQUAL -
POLYETHYLENE VAPOR BARRIER. W/ 2" X 2" X 1/8"
HOLD MESH IN TOP 1 1/2" OF SLAB. STEEL WASHER AT
36" O.C. U.N.O.
BASE TRIM PER SPECS
EXTEND PARGE COAT 4" ELEV AT 0'-0"
BELOW GRADE TYP. 1 ST FLOOR FF =
ELEV AT 0'-0" GRADE
1ST FLOOR FF
° za
`v
a ° ar
d
a
a =
0
o ° o
(1) #5 REBAR CONT.
ON #3 WIRE CHAIRS 8"
CLEAN POISONED AT 6'-0" O.C. TYP.
AND COMP. SOIL
4" 1'-4"
(2) #5 BARS CONT
2 TYPICAL WALL SECTION AT WINDOW ONE STORY
3/411— 11-019
PRE-ENGINEERED WD. TRUSSES AT 24"
O.C. MAX. W/ GALV. MTL. SEAT PLATES
SLOPE
PER
1/2" PLYWD SHEATHING NAILED W/ 8d RING
SHANKS AT 4" O.C. (EDGE), 6" O.C. (FIELD) W/
ELEV.
GALV. CLIPS
ROOF FINISH PER ELEVATION
PTA20 EACH TRUSS U.N.O. -
SEE FRAM FRAMING
R-30 INSULATION MIN
ELEV AT 8'-0"
Y FIRST FLR CLG
THE GARAGE IS TO BE SEPARATED —
FROM ADJACENT LIVING AREA AND
ATTIC SPACE BY 1/2" GYPSUM BOARD
AND HABITABLE ROOMS ABOVE BY
NOT LESS THAN 5/8" THK. TYPE "X"
GYPSUM BOARD (OR EQUIVALENT)
APPLIED TO THE GARAGE SIDE.
FOR ALL GARAGE DR. WIDTHS PROVIDE
2X8 P.T. HEAD & JAMBS
FOR 8'-0" & 9'-0" WIDE DRS. PROVIDE (3)
1/2" DIA. X 6" "J"-BOLTS AT EA. JAMB
EQUALLY SPACED
FOR 16'-0" & 18'-0" WIDE DRS. PROVIDE (4)
1/2" DIA. X 6" "J"-BOLTS AT EA. JAMB
EQUALLY SPACED
FOR ALL GARAGE DR. WIDTHS FASTEN
HEAD W/ 2 1/2" PINS USING POWER
ACTUATED DEVICE
PROVIDE MIN. 3/4" EDGE DISTANCE TO
"J"-BOLTS IN 2X6 JAMBS TYP.
4" THICK
CONCRETE SLAB
GARAGE PITCH
1/8" PER FT
NOTE: REFER TO ELEVATION
SHEET FOR SOFFIT AND
FASCIA DETAILS
PER
ELEV.
(1) COURSE 8 X 8 KNOCK- OUT BLK
FILLED SOLID W/ (1) #5 BAR TYP.
4 X 8 X 16 PARTIAL BLOCK
8 X 8 PRE CAST CONCRETE "U"
LINTEL FILLED PER CALL OUT ON
FLOOR PLAN
DECORATIVE CEMENITIOUS COATING
TYP. U.N.O. AT EXT. MASONRY
WALLS. SEE ELEVATION SHEET FOR
TEXTURES
NOTE: SEE PLANS FOR FINISHES
AND TRIM WORK NOT SHOWN HERE
EDGE OF BLK.
WALL BEYOND
GARAGE DR.
COLD JOINT
CONCRETE DRIVEWAY
`v
cn
° a
a d °
Q °
v a
°
a a
0
_
a Q e M
CLEAN POISONED
AND COMP. SOIL (2) #5 BARS CONT
°
a
WD TRUSS SEE
FRAMING PLAN
(TRUSS TYPE MAY
VARY FROM TRUSS
SHOWN)
THE GARAGE IS TO BE
SEPARATED FROM
ADJACENT LIVING AREA
AND ATTIC SPACE BY 1/2"
GYPSUM BOARD AND
HABITABLE ROOMS ABOVE
BY NOT LESS THAN 5/8"
THK. TYPE "X" GYPSUM
BOARD (OR EQUIVALENT)
APPLIED TO THE GARAGE
SIDE.
2X CONT. TOP PLATE
eT1if—Tel A
2X BLOCKING. AT
MID POINT OF
WALL (4" O.C.
STAGGERED
MAX)
1/2" DRYWALL,
TYP. U.N.O.
—I 2X P.T. SILL PLATE
/1• GARAGE PITCH.
1/8" PER FT
4" THICK
GO CONCRETE
SLAB
5 PARTITION AT GARAGE
3/411— 11-011
ENTRY DOOR
SET THRESHOLD IN
FULL BED OF CAULK
VERIFY FINISH
MATERIALS W/
OWNER
FINISH FLOOR
ELEV AT 0'-0"
v a
a
4 °
_ ° 4
o a o
CLEAN POISONED
AND COMP. SOIL
4" 1'-4"
8 FRONTENTRY - MONO FTG
3/4 S — 1 -0
GARAGE
DOOR —
SERVICE DOOR
WOOD CASING
MT'L THRESHOLD IN 4 1/2"
FULL BED OF CAULK
GARAGE SLAB _ PITCH
d 1/8" PER FT
M
a a v
a
° d
a °
°
CLEAN POISONED)
AND COMP. SOIL
SERVICE PAD SEE
(2) #5 BARS CONT 1'-4" FLOOR PLAN FOR
SIZE AND LOCATION
COLD JOINT
D6 SERVICE �DOOR - MONO FTG.
3/4 — 1 -0
LANAI PITCH 4" THICK CONCRETE
SLAB
1" IN 12'-0" GRADE
v
_
a
8" THICKEN
4-1 g" EDGE W/ (1)
#5 CONT
7DLANAI DETAIL
3/411— 11-011
4" THICK CONCRETE
rlliiik LANAI PITCH SLAB
1" IN 12'-0" GRADE
°
da a v
e a a
a =
° - Y
a a °
0
16" X 16" FOOTING
W/ (2) #5 BARS CONT
7.1 LANAI DETAIL
3/4 — 1 -0
PITCH
`v
O
M 4" 41 8"
COLD JOINT
(2) #5 BARS
CONT
CONT. WEATHER STRIP �� ft
CONT.IN 14
••DTRIMJI
(5) 1/2" 0 X 8" "J" BOLTS
FILLED CELLS W/ #5 VERTICAL
EXTERIOR - C.M.U.
VERIFY FINISH
MATERIALS W/ OWNER
WALKWAY,
AS OCCURS
=v
° v
COLD JOINT
8" THICKEN
EDGE W/ (1)
#5 CONT
DOOR AND CONNECTION
PER GARAGE DOOR
MANUFACTURER, TYP.
#2 SYP P.T. 2 X 8
PT WD JAMB
°
w
=
cn
0u
Q°N
z
00=
p
w
0 W Z
H
Ln 00 _
N J
LU U
W
J
w 2 Q
H
O
w�W
�w0
75
� U�
w
_f
0
w
= 0 0
>w
0:
0 cn
z
wO-,Z
0
m~aLU
9a
a'ZQ'J
�w
=o°0=2
_ u. U. cn
E— cn
73
LL
,0
0
^c:
W
c:
cu
I_—
E
M
U
M
Q
^♦
W
J
LL
0
(1)
uj
OC)
—
u�
0
ti
ti
C)-
W
>0
W
a)
N
W
Q
—
�
U
j
w
�
-o
a.
v/
Q
E
C
0
.c:
CD
U
L
iz
N
co
-#- a
C�
M
�
c:
0
(1)
U
a)0
V)
c/)
^♦
WI..L.
^^cu
Jc
ISSUE DATE: 05/06/10
JOB CAPTAIN: JMG
SCALE: AS NOTED
CHECKED BY: JMG/PF
PROJECT NUMBER: 0737
STRUCTURAL
DETAILS 2
4" l'-4" 01
3 NOT USED 4113/411TYPICAL WALL SECTION AT GARAGE ONE STORY 9 GARAGE TRACK MOUNTING
N.T.S. —1 -0 N.T.S. �::j
S2
L _ —
KEYNOTE
LEGEND FOR DETAIL
#5 IN CELL
POURED SOLID
KEYNOTE
ANNOTATION
G
ENTRY PITCH
ENTRY PITCH 0.. 6X6 P.T. WD
CONCRETE SLABS ON GRADE SHALL BE
1/8" PER FT 6X6 P.T. WD
1/8" PER FT o POST OR U.N.O.
PROVIDED WITH JOINTS IN ACCORDANCE WITH
20" MIN. LAP
POST OR U.N.O.
SIMPSON ABU66
1O
ACI 224.3R OR OTHER APPROVED METHODS.
FILLED CELLS
LANAI PITCH SIMPSON ABU66
< OR U.N.O.
JOINTS ARE ONLY REQUIRED IN UNREINFORCED
1" IN 12'-0" OR U.N.O.
16" SQ CMU
PLAIN CONCRETE SLABS THAT COMPLY WITH
a
F.B.C. 2007, RES., SEC. R506.2.5
#3 OR #4 REINFORCING BAR
All
GRADE
BASE FILLED
SOLID W/ #5
#3 & #4 LAP SPLICE
a ` " ' °
p D D =
a (2)
a
° D
ELEV AT 0'-0" a a BARS CONT
1 1/4" DEEP SAWCUT CONTROL JOINT, TIME FRAME
WITHIN 4 TO 12 HOURS AFTER THE CONCRETE HAS
D °
1ST FLOOR FF GRADE
O
BEEN FINISHEDS (SEE PLAN FOR EXACT
25" MIN. LAP
#5 BARS
D o
D
LOCATIONS), CLEAN AND SEAL JOINT AGAINST
=
SOIL -GAS ENTRY (F.B.C.2007, SEC. F303.3)
e °
CONCRETE SLAB OVER VAPOR RETARDER OVER
#5 REINFORCING BAR
#5 BARS AT
1 v
SELECT WELL -GRADED, TERMITE TREATED FILL
COMPACTED TO 95% MAXIMUM DENSITY,
#5 LAP SPLICE
a ° Lu
6" O.C. E.W.
°� • ° •
4
REINFORCING AS DESIGNED BY ARCHITECT OR
Q
2'-0" 24" SQ X 12" DP
4 a
ENGINEER.
36" MIN. LAP
CONC FOOTING
#5 BARS AT
° a
°
U
6" O.C. E.W.
a
CONCRETE SLAB: SHALL BE 4" THICK AND SHALL
w
2,_0n 24" SQ X 12" DP
MEET MIN COMPRESSIVE STRENGTH AS
J
CONC FOOTING
ONE STORY POST DETAIL
ONE STORY POST DETAIL
4
O
SPECIFIED BY THE ARCHITECT OR ENGINEER.
#6 REINFORCING BAR
<
3 5 6
(F.B.C.2007, RES, SEC, R506.1, F303.4.5)
#6 LAP SPLICE
y
J3/4"=1'-0"
9' 1
3/4"=1'-0"
10"
VAPOR RETARDER: 6 MIL. POLYETHYLENE OR
5O
APPROVED EQUAL WITH JOINTS LAPPED NOT LESS
TOP OF
THAN 6". (F.B.C. 2007, RES, SEC. R506.2.3)
##55 REINFORCING
FLOOR
SIMPSON MGT. W/22-10d - <
BAR
7/8"
F
COMMONS W/ 5/8" DIA '• .�
'
ATR W/ 5"
w
w
.• ••
,• ,.
REINFORCING: REINFORCED PURSUANT TO ACI 318,
<
SEC. 22.3, WELDED WIRE REINFORCEMENT MESH
a
8" KNOCKOUT
PLACED IN THE MIDDLE OF THE UPPER THIRD OF
BLOCK SEE PLAN
6O
THE SLAB AND IN ACCORDANCE WITH THE PLAN
,
SPECIFICATIONS OR SYNTHETIC FIBER
FOOTING FOUNDATION 2'-0" MIN
REINFORCEMENT INSTALLED AS DIRECTED BY THE
MANUFACTURER OR SUPPLIER. (F.B.C.2007, RES,
WALL
-
SEC. 506.2.4
GIRDER BM. OR
RUSS(LVL
SLAB DETAIL
REBAR DETAILS
TYPICAL MASONRY SHEARWALL
1
SHOWN)
N.T.S.
±4jN.T.S.
5
N.T.S.
GIRDER/ MASONRY WALL
10
N.T.S.
SIMPSON HW W/ OFFSET
CONC. TIE BEAM W/ NOTCH LINTEL WHERE
TOP FLANGE SEE MANUF.
(1)#5 CONT. REQUIRED FOR
LANAI BEAM-
CATALOG FOR HEIGHTS
1 2 2 NOTES:
CONCRETE PLACEMENT
& WIDTHS MICRO -LAM OR
OTHER (SEE PLAN
4 .
° ,
MANUFACTURER'S
FOR SIZE)
OSEE
INFORMATION FOR WINDOW / DOOR
°
°
°
SEE BEAMS TO
° a
ATTACHMENT TO FRAME.
a e. o
MASONRY DETAIL
MASONRY SEE MANUF.
1X8 P.T. ANCHORED TO LINTEL AND
WALL SPECS FOR
NAILING REQ., S
4 O WALL W/ 1/4"X2" TAPCON AT 12"L
PRECAST LINTEL
3 O.C.
it
,
a..
8
BEAMS PER LANAI BEAMS
G 4 NAILED O P
ANGLED 2X NA T LATE W/(2)
PLAN °
3 16d NAILS AND COVER W/ 1/2"
-
- O
SIMPSON E E
O CC SE MANUF. CATALOG
-
PLYWD OR 7/16" OSB W/8d NAILS AT
FOR BEAM COMBINATIONS FOR
— 4" O.C. (EXTERIOR AND INTERIOR
1
LEFT HEIGHTS & WIDTHS
SIDES).
a
4
PLAN VIEW P.T. POST SEE
FILLED CELL W/ (1)#5
PLAN FOR SIZE
ANGLED 2X4 NAILED TO PLATE W/(2)
VERT.
a
SQUARE ARCH -CIRCLE TOP - LESS THAN 3' SPAN ROUND OPENING 4O 16d NAILS.
CORNER POST CONNECTION
11
N.T.S.
2X4 CRIPLE VERT STUDS AT 8" O.C.
50 AND ANGLES NAILED TO PLATE
°
BEAMS PER PLAN
NOTES:
W/(2) 16d NAILS AND COVER W/ 1/2"
SEE SPECS
PLYWD OR 7/16" OSB W/8d NAILS AT
4" O.C. (EXTERIOR AND INTERIOR
1. FILL LINTEL AND ALL CELLS ABOVE LINTEL
SIDES).
2. VERIFY THAT ALL REINFORCEMENT HAS BEEN PLACED PROPERLY
--- -
PRIOR TO POUR.
DOUBLE 2X4 VERT AT EACH SIDE
LSTA24
- __ _-_-_- __ - O OF WINDOW SHAPE CHANGES,
W/7-SP
Od TO BEAM &
ATTACHED TO TOP PLATE W/
7-10d TO COL.
2 5 6 2 7 SIMPSON MGT OR USP MUGT15 W/
SUPPORT COLUMN
5/8n X4a ANCHOR BOLT.
BUILT-UP (3)2XSi OR
4X4
�
TYP. LINTEL ASSEMBLY OPENING LESS THAN 9 —011
7
n
X.T.S.
2 4 CRIPLE VERT STUDS AT 8 O.C.0 C
� (1) USP HETA20
-- - _- - -
- -- - - - 7 NAILED TO PLATE W/(2) 16d NAILS
O
W/1110d X 1 1/2
AND COVER W/ 1/2" PLYWD OR 7/16n
a . TO COL.
OSB W /8d NAILS AT 4n O C
(EXTERIOR AND INTERIOR SIDES).
TIE BEAM
ARCH -CIRCLE TOP - MORE THAN 3' SPAN MULTI -VARIETY TOP O DOOR OPENING AREA (TYPICAL)
CONC. TIE BEAM W/ NOTCH LINTEL WHERE
(1)#5 CONT. REQUIRED FOR
CONCRETE PLACEMENT
MASONRY WALL
a
° .14
4
°a a�
a
a
a
MASONRY WALL
WINDOW AND DOOR MOUNTING — MASONRY
s
12
N.T.S. BEAM AT RAISED ENTRY
PRECAST
°
2
N.T.S.
LINTEL
a
8" H. KNOCKOUT
8" H. KNOCKOUT
8" H. KNOCKOUT
a
MASONRY WALL
°
BLOCK FILLED SOLID „
BLOCK FILLED SOLID a,
�
BLOCK FILLED SOLID
WI (1) #5 BAR
W/ (1) #5 BAR
W/ (2) #5 BAR
a
ATTACHMENT PER
MASONRY MANUFACTURES
4
WALL SPECIFICATIONS.
°.
FILLED CELL W/ (1#5
SEE MANUF.
8"X8" PRECAST CONC
8"X8" PRECAST
8"X8" PRECAST CONC
8"X8" PRECAST CONC
VERT.
•� SPECS FOR
"U" LINTEL FILLED
CONCRETE "U"
"U" LINTEL FILLED
"U" LINTEL FILLED
,
BEAMS .' NAILING REQ.
SOLID W/ (1) #5 BAR
LINTEL
SOLID W/ (1) #5 BAR
SOLID W/ (1) #5 BAR
PER
PLAN
°
4
SIMPSON MBHA NOTE:
SEE CORNER SEE MANUF. CATALOG
NOTES:
1. FILL LINTEL AND ALL CELLS ABOVE LINTEL
POST DETAIL FOR OTHER BEAM
RIGHT LANAI BEAM- COMBINATIONS FOR
MICRO -LAM OR OTHER HEIGHTS & WIDTHS
PC-1
PC-2
PC-3
PC-4
2. VERIFY THAT ALL REINFORCEMENT HAS BEEN PLACED PROPERLY
PLAN VIEW
(SEE PLAN FOR SIZE)
PRIOR TO POUR.
THE K.O. BLOCK ABOVE THE LINTEL IS THE MINIMUM REQUIRED. ADDITIONAL GROUT FILLED CMU BLOCKS CAN BE INSTALLED BETWEEN
THE K.O. BLOCK AND THE LINTEL FOR HIGH REQUIREMENTS. THE K.O. BLOCK ABOVE CAN BE THE SAME AS THE WALL TIE BEAM.
TYPICAL PRECAST LINTEL
TYP. LNTL. ASSEMBLY OPNG. GREATER THAN 9'-011
BEAM TO MASONRY WALL CONNECTION
3
8
13
3/411= 1 —O NOTE: PRECAST LINTELS SHALL BE CAST CRETE OR EQUAL.
"
N.T.S.
N.T.S.
LLI
°'
F=
zLL
"it g
CD
N
0 W
w
i?5
U)
w
ow 0
z
Ln to- Fn
w
w
� N J
W U
H
LL
W m Z
J
U)
W=Q
►_—
w?�W
�Wp
0
j Z
-
o
=Qw
Ix
§
J
0
=0O-
~00
>W
L}L�z
fnJ
w
zp
O
w0��
UHmz
3:z
Cl
LLJ��LU
w z ZE J
a w
(n z
0
=OJT
_(D
z
— LL LL U)
I— (n
Q
c
LL
, 0
",
^c
W
E
M
J
O
^'
W
LL
uj
0
�
Q>%
0
Ll.
0
I`
co
Q
>O
W
Q
N
W
Q
�--+
C:
w
j
IZ
�
=
•O
cn
Q
E
cm
E.
0
.c:
'1-
U
L
c
co
co
co
c:
C
0
(1)
U
W
O
VJ
^♦
^^cu
rm
BY
REVISION
DATE
JC
REV.01
08/24/09
JMG
REV.02
05/03/10
ISSUE DATE: 05/06/10
JOB CAPTAIN: JMG
SCALE: AS NOTED
CHECKED BY: JMG/PF
PROJECT NUMBER: 0737
STRUCTURAL
DETAILS 3
S3
I A I f. _. _
a
_
7
7/8" PARGE COAT OF
CEMENTITIOUS FIN. ON
MTL. LATH ON 15# FELT
1/2" PLYWD. SHEATHING
NAILED W/ 8D
COMMONS AT 4" O.C.
(EDGE), 6" O.C. (FIELD)
15# FELT
PAPER CONT.
SECURE MASONRY
WALL TO KNEE WALL
W/ SIMPSON H21
2 X TRUSSES AT 24" O.C.
SECURE TRUSS TO KNEE WALL
WITH SIMPSON H1
PER PLAN
ENTRY CLG
SECURE KNEE WALL TO TRUSSES W/
SIMPSON H2
SIMPSON HHETA20
USP HTA20
I �(1) COURSE 8 X 8 KNOCK- OUT BLK
:FILLED SOLID W/ (1) #5 BAR TYP.
4 X 8 X 16 PARTIAL BLOCK
LF
I
7/8" (3) COAT —
STUCCO FIN.
1 /4" METAL
LATH
1/2" SHEATHING
5/8" (2) COAT —
STUCCO FIN.
3/4"
I
NOTE: AT GABLE END AND
OTHER EXT. FRAME ON BLOCK
APPLICATIONS, INSET TRUSS OR
FRAMING 1/2" TO ALLOW FOR
SHEATHING
1 KNEE WALL ABOVE MASONRY - ENTRY
3/4 — 11-011
DOUBLE
TOP
PLATE
(3)-8d COM.
10d CORARMN
AT 12"
(4)-10d
COMM,
STUDS
AT 16"
-{2)-16d
COM.
4-
CI
16d COM.
AT 12" OC
(2)-8d COM.
PT BOTT.
PLATE
DOUBLE END STUD
(4)-16d
COMMON
(2)-16d
COMMON
(3)-10d
COMMON
EA. SIDE
OF JOINT
TOP PLATE FASTENERS
DOUBLE TOP
PLATE
12d COM. AT
12" OC
DOUBLE (3)-8d COM. —(6)-16d COM.
STUD
BOTT.
ATE
-8d COM.
16d COM. AT 12"
41 O.C. EA. STUD
(2) 2X12 W/ 1/2"
PLYWD. SPACER
12d COM.
AT 8" O.C.
USE SIMPSON HEADER
HANGERS HH4 OR USP HH44
EXT./BEARING WALL HEADER
IDUIT 1-1/2"
3REATER
STUD SHOE
IPSON SS3
DN SS1
(2) SIMPSON HHETA20 OR
USP HTA20 AT MASONRY OR
(2) SIMSPON MTS20 OR USP
MTW20 AT FRAME U.N.O.
K3 HIP FRAMING
N.T.S.
0
z
w
(L_
END JACK
11'-0" MAX
ti%4
Ala
CORNER JACK
Y
�
w
U
of
C7
w
z
a_
Of
0
=
U
20'-0" MAX
"X" BRACE SEE DETAIL
ON THIS SHEET —�
SIMPSON HETA20 OR USP HTA20 AT
MASONRY
SIMPSON H10 OR USP RT16 AT FRAME
WALLS(TYP)
20'-0" MAX
CONTINUOUS BOTT CORD
BRACING 1"X4" MIN. —�
d
w
0
0
0
0
C'1
w
---
ZL
NOTE:
1) SEE TRUSS MANUFACTURER'S TRUSS ENGINEERING
CUT SHEETS FOR ADDITIONAL PERMANENT BRACING
THAT MAY BE REQUIRED.
2) "T" BRACING MAY BE USED IN PLACE OF PERMANENT
BRACING PROVIDED IT EXTENDS OVER AT LEAST 90% OF THE WEB.
TOP & BOTTOM CORD
GABLE END BRACING AT
4'-0" O.C. MAX FOR
FIRST (4) ROWS OF TRUSSES
4 MINIMUM PERMANENT TRUSS BRACING PLAN
N.T.S.
BEARING WALL HEADER CHART
BEAM
TRUSS SPAN - SHINGLE ROOF
SPAN
24
28
32
36
40
44
48
6
2X8
2X8
2X8
2X8
2X8
2X10
2X10
7
2X8
2X8
2X10
2X10
2X10
2X10
2X10
8
2X8
2X10
2X10
2X10
2X12
2X12
2X12
9
2X10
2X10
2X12
2X12
2X12
2X12
-
10
2X10
2X12
2X12
2X12
-
-
-
11
2X12
2X12
-
-
-
-
-
12
2X12
2X12
-
-
-
-
-
BEARING WALL HEADER CHART
BEAM
TRUSS SPAN - TILE ROOF
SPAN
24
28
32
36
40
44
48
6
2X8
2X8
2X8
2X8
2X10
2X10
2X10
7
2X10
2X10
2X10
2X12
2X12
2X12
2X12
8
2X10
2X12
2X12
2X12
2X12
-
-
9
2X12
2X12
2X12
-
-
-
-
10
2X12
2X12
-
-
-
-
-
ALL RAFTERS SHALL BE #2 SOUTHERN YELLOW PINE.
SECTION SIZE SHALL BE DETERMINED ACCORDING
TO THE LENGTH OF SPAN AS FOLLOWS:
UP TO 8'-0" ........... 2X6
8'-0" TO 12'-0" ........... 2X8
12'-0" TO 15'-0" ........... 2X10
15'-0" TO 18'-0" ........... 2X12
1/2" 4 PLY CDX PLYWOOD
W/ GALV. CLIPS
HATCHING INDICATES
FRAMING AND
SHEATHING TO BE o
BUILT ON TOP OF
6 CONVENTIONAL FRAMING DETAIL
N.T.S.
BRACING 1"X4" MIN.
SECURE RAFTERS TO CLEAT USING SIMPSON MSTA24
TENSION STRAPS. SEE MANUFACTURERS
SPECIFICATIONS FOR FASTENER QUANITY.
CLEAT SHALL BE A #2 SOUTHERN YELLOW PINE 2X10.
IT SHALL BE FASTENED W/ SIMPSON MSTA24
TENSION STRAPS AT EACH TRUSS USING (18) 10d
NAILS. INSTALL THE STRAP BY CUTTING A HOLE INTO
THE SHEATHING AT EACH SIDE OF TRUSS AND
THREADING THE U-SHAPED STRAP FROM BOTTOM
OF TRUSS TOP CHORD TO TOP OF CLEAT.
RIDGE BEAM SHALL BE #2
SOUTHERN YELLOW PINE. SECTION
SIZE SHALL BE 2" (NOMINAL) LARGER
THAN RAFTERS W/ A MAXIMUM
RIDGE SIZE OF 2X12 FOR 2X12
RAFTERS.
SECURE RAFTERS TO RIDGE BEAM WITH
SIMPSON LSU AT EACH RAFTER. SEE
MANUFACTURERS SPECIFICATIONS FOR
FASTENER QUANITY.
2X4 COLLAR TIE MID -HEIGHT
AT RAFTERS. PROVIDE (5) 12d
NAILS EA END
NOTES:
RAFTERS SHALL BE #2 SOUTHERN
OALL
YELLOW PINE. SECTION SIZE SHALL BE
DETERMINED ACCORDING TO THE LENGTH
OF SPAN AS FOLLOWS:
UP TO 8'-0" ........... 2X6
8'-0" TO 12'-0" ........... 2X8
12'-0" TO 15'-0" ........... 2X10
15'-0" TO 18'-0" ........... 2X12
BEAM SHALL BE #2 SOUTHERN YELLOW
ORIDGE
2
PINE. SECTION SIZE SHALL BE 2" (NOMINAL)
LARGER THAN RAFTERS W/ A MAXIMUM RIDGE
SIZE OF 2X12 FOR 2X12 RAFTERS.
OCLEAT SHALL BE A #2 SOUTHERN YELLOW PINE
3 2X10. IT SHALL BE FASTENED AS SHOWN W/
SIMPSON MSTA24 TENSION STRAPS AT EACH
TRUSS USING (18) 10d NAILS. INSTALL THE STRAP
- SECURE RIDGE BEAM BY CUTTING A HOLE INTO THE SHEATHING AT EACH
TO GIRDER W/ USP SIDE OF TRUSS AND THREADING THE U-SHAPED
UH26 JOIST SEAT W/ (8) STRAP FROM BOTTOM OF TRUSS TOP CHORD TO
16d NAILS TO GIRDER & TOP OF CLEAT.
(3) 16d NAILS TO RIDGE
BEAM
2X4 COLLAR TIE SECURE RAFTERS TO CLEAT USING SIMP
MID -HEIGHT AT
4
SON
MSTA24 TENSION STRAPS. SEE
RAFTERS. PROVIDE (5)
MANUFACTURERS SPECIFICATIONS FOR
12d NAILS EA END
FASTENER QUANITY.
- CONTINUE SHEATHING
BELOW CONVENTIONAL
SECURE RAFTERS TO RIDGE BEAM USING
FRMG AT ATTACHED
5
SIMPSON LSU HANGER SLOPING JOIST SEAT.
STRUCTURES WHICH ARE
SEE MANUFACTURERS SPECIFICATIONS FOR
ONLY PARTIALLY
FASTENER QUANITY.
ENCLOSED SUCH AS
ENTRYWAYS AND PORCHES
INDICATES TRUSSES
16d PER JOINT —
00
41MUM 2"X4" OSS OVERHANG
ACING (SEE PLAN INDICATES 4X8
R LOCATIONS) USE 8d RING 4'-0" 4'-0" SHEATHING SHEETS
SHANK NAILS END ZONE END ZONE
® = 4" O.C. FIELD AND EDGE
= 4" O.C. EDGE 8" O.C. FIELD
~Cl
zu
Q0N
w
o
N
z0=
F-
co
`r'
w
w00
0 w Z
=
U)00
cr.
�NJ
U
F-
LL
WLU
m 4-U)
J
w=Q
j
z
wow
Wwo
O
Is
> Z U)
—
o
93
= Q �
w
=oo
LL
p
>W
w
>- z (9
�m
(90)
0
vomz
3:Z
m~Qg
la J
O'Zw-J
w� a
O
�w
��
o
Q
=U-U-cco
coH
C
C
U-
"0
c
cu
r.
clq
'wt
E
M
U
CM
C-
^'
W
J
LL_
0
0—
N
cn
j,
0
ti
Q
W
�
�--+
O
W
N
N
a-
U
>
a
:3
E
-
O
�a
E
��
0
._
(o
U
N
Cn
00
M
�
:3
C
0
0
U
�
O
VJ
Al
^^cu
ISSUE DATE: 05/06/10
JOB CAPTAIN: JMG
SCALE: AS NOTED
CHECKED BY: JMG/PF
PROJECT NUMBER: 0737
STRUCTURAL
DETAILS 4
WALL FRAME DETAILS BEARING WALL HEADER CHART CROSS BRACING NAILING DIAGRAM
2 N.T.S. L5 N.T.S. L� N.T.S. j8j N.T.S.
S4
P:\Projects\2007 Projects\0737-Pasco County - Affordable Housing\Keystone Challenge Fund\Seven Springs\Sheets\PA Sheets\PA Product Approval Sheet 01.dwg, 5/6/20101:46:20 PM, jcallahan, Oce TDS600 3.x.pc3, ARCH D (36.00 x 24.00 Inches), 1:1
11T
114" MAX, SHIM
(MIN. EMBEDMENT)
I (SEE NOTE 2 & 3 ON BHT. 2)
CAULK BETWEEN BUCK
I
1/4" MAX SHIM ���•jj(
1w
(I_urMIN.
AND OPENING BY OTHERS (MIN. EDGE asTJ
p •p
• ;
ANCHOR
(SEE NOTE 2 & 3
ON SHT. 2)
(MIN EMBEDMENT)
�'•
LIP
. .
A
21/r
gip•
• p; p• ANCHOR,
CONCRETE/MASONRY -�
(MIN. EDGE DIST.)
• ' •
p p
INSTALLATION ANCHOR,
DMA. MASONRY ANCHOR.
ANCHOR
p •10 SCREW
$10 WOOD r
BY OTHERS
. •
3118'
CUP
•
p D� • D p• p
p
M�-
a• •a
o •
• • p • • p • p •
• 06 D.
• • •
1 BY WOOD BUCK
• • i• CAULK BETWEEN BUCK
•p e
p D • ► p ' • p `
• •p • •
I_1w
p • p •
BY OTHERS
• 4 AND OPENING BY OTHERS
•. • • r 9• r P•. •
�• Q • p
WNEMBEDMEN
( T)
• •
• i
�
O e
•
. ►
s, •s•
• p
p
•�'
A ; A ;
. p p 2 BY SLICK
•
��� BY OTHERS
EXTERIOR FINISH
BY OTHE18
-4_ 1/4' MAX SHIM
• •
p . •p •
. •
• •
• 4. p• p
(SEE NOTE 2& 3
ON SHT. 2)
• • CONCRETEIMA30NRY
PERIETER CAULK
BY INSTALLER
1 BY WOOD BUCK
•
p •�
• p . p / BY OTHERS
p• f
Br OTHERS
p . p
• •
WINDOW FRAME
• •
. 6'
•QP•
•• JAMB
PERIMETER CAULK
Co.
WINDOW FRAME
ANCHOR
CLIP
• •
Oo PERIMETERCAULK
BY INSTALLER
qRY
HEAD"•
BY INSTALLER
_ nn -
INSTALLATION ANCHOR,
EXTERIOR FINISH -� �1
SECTION
3116"DIA. MASONRY ANCHOR.
(91 ►IDifI EONTAL SECTION
T CLW (MASONRY)
BY OTHERS
CUP (WOOD)HORIZONTAL
ANCHOR
CAULK BETWEEN BUCK
CLIP
AND OPENING BY OTHERS
WINDOW FRAME
SILL
INSTALLATION ANCHOR,
3116' DIA. MASONRY ANCHOR.
PERIMETER CAULK
BYINSTALLER
114" MAX. SHIM
�- (SEE NOTE 2 & 3
EXTERIOR FINISH
ON SHT. 2)
WINDOW FRAME
BY OTHERS D • • • • • '
D •
SILL
D
INSTALLATION ANCHOR,
3118' OIA MASONRY
• • D ► P • P
' • D • • • ► •
'
' D
1 17M
PERIMETER CAULK
ANCHOR
• �► ' i p • D • D D D
P •
(MN. EMBEDMENT)
BY INSTALLER
ANCHOR
CUP
► p • p . • D • ♦ _ •
D • p p
• D . •
114" MAX SHIM
• • D
D �• P•
D • D
EXTERIOR FINISH
(SEE NOTE 2 & 3
p D p •
211?•
BY OTHERS
ON SHT. 2)
OTHERS 30NRY
(MIN. EDGE DIST.)
•• •
BY
PRECAST
1 BY WOOD BUCK
(l3L LTERNATE SILL DETAIL
q UPDATED
PER NEW fBC REQUIREMENTS 07107108
•` i .
By OTHERS
\ CUP (MASONRY)
.� :• :
•; : ie
• . • . • . ► . •• ► .
w •
(MIN EMBEDMENT)
, •
.. • • ;�. • a , , ..
• • • • •
, •• , .Yi•
�\
v SW 44TH AYE.
°� ` FLORIDA 34474
,
CONCRETEILMSONRY
BY OTHERS
21w
(MIN. EDGE DIST.)
^'
, . I LATION DETAIL W LIP - IMPA T
'.:
PVC SINGLE HUN ADEATE* 7r7nooe
rAI VERTICAL SECTION
THE INFORMATION
PROPMETARY AND C01FIDEWTUL
CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY 4-MeAM
- }i • I s� ' L • E _t •
C. �4DEf(TOT•pf� :.. u 8100
NITS CWS-155
QLTCLIP(MASONRY)
WINDOW SYSTEMS. INC. ANY REPRODUCTION IN PART OR AS AW+IOLEWU1WLMv (E
FL. P.15030. 62514 -
%WTTFN PFR MISSION OF CUSTOM WINDOW SYSTEMS. INC. IS PROI�010171[) -
.. • ;.
Ar1IT -6 OF
l
•
(MIN EMBEDMENT) 114' MAX SHIM - Law
DRYWALL �\ (SEE NOTE 2 & 3 ON SHT. 2) (MIN. EMBEDMENT)
BY OTHERS \ 1 8Y WOOD BUCK
�\ BOTHERS Y • DRYWALL
DRYWALL ! I 'i' ' 1l4" MAX SHIM a ♦' BY OTHERS
BY OTHERS CONCRETE/MASONRY •f•A •f•1•' (SEE NOTE 2&30NSHT, 2) •1�„tip„
21/7" BY OTHERS
A•A•
(MIN EDGE DIST.) �♦ � ♦ -CAULK UNDER SCREW
INSTALLATION ANCHOR, 3/16• DMA. � HEAD BY INSTALLER
CONCRETEPMASONRy • '' MASONRY SCREW WT4EOPRENE
BY OTHERS •y BACKED WASHER THRU SCREW • • '
• . • 3L1PPgiT • 2 BY WOOD BUCK
CAULK BETWEENIFRA.
• ► • .� • %• • j • • • , '' ,•, ♦ A . • BY OTHERS
BUCK AND OPENI
BV OTHERS 1 BY WOOD BUCI( (MIN EMBEDMENT) • ' . ' WIND0MW FRAME • INSTALLATION ANCHOR, 010 DIA
BY OTHERS z 1n' JAMB
.WOOD WASH R NEOPRENE
EXTERIOR FINISH (MIN. EDGE DIET.) 4 • 1 ♦ SUPPORKEO WASHER THRUSCREW
BY OTHERSSUPPORT
L(SEE NOTE 2 & 3 ON SHT. Z) 114" MAX SHIM
PERIMETERCAULK PERIMETER CAULKPERIMETER CAUBYINSTALLER BY INSTALLERBYINSTALLER CAULK UN DER EXTERIOR FINISH EXTERIOR FINISH CAULK BETWEEN
SCREW HEAD BY INSTALLERS CAULK BETWEEN BY OTHERS BY OTHERS BUCK AND OPENING
BUCK AND OPENING BY OTHERS
WINDOW BY OTHERS HORIZONTAL SECTION HORIZONTAL SECTION
HEAD FRAME((MASONRY) 7 FRAME (WOOD)
INSTALLATION ANCHOR, 3116' DIA.
MASONRY SCREW wdNEOPRENE
BACKED WASHER THRU SCREW CAULK UNDER SCREW
SUPPORT HEAD BY INSTALLER
WINDOW FRAME INSTALLATION ANCHOR, 3116"DIA.
SQL MASONRY SCREW WWNEOPRENE
BACKED WASHER THRU SCREW
SUPPORT
INSTALLATION ANCHOR, 3716' DIA. PERIMETER CAULK j` 1/4' MAX SHIM
MASONRY SCREW WWNEOPRENE BY INSTALLER (SEE NOTE 2 & 3 ON SHT. 2)
WINDOW FRAME BACKED WASHER THRU SCREW
BILL SUPPORT
MIT. FINISH D • ' • • ' ' • D
BY OTHERS • D D
CAULK UNDER D D . • • II , •_ D
SCREW HEAD HIGH STRENGTH STRUCTURAL • ► • P . D • (MIN
T)
BY INSTALLER GROUT BY OTHERS D • i �. P•D • e D► D D' 6 • S •• ►p (MIN EMBEDMENT)
i . to
PERIBYINSTALLER CAULK •
LLER V4' MAX SHIM D • b i D D D• �• pD . i D' i
(SEE NOTE 2 & 3 ,•I z-
ON SHT. 2}
EXTERIOR FINISH EREAASCkIRV (MIN EDGE DIST.)
BY OTHERS
BY OTHERS BY OTHERS L'p1ALTERNATE PRECAST SILL DETAIL
�} ' , �! • SILL s7ool ' 7 FRAME (MASONRY) A UPDATED PER NEW FBC REQUIREMENTS 07107MS
►• • BY OTHERS
► ; ► . ► •► . , • • •. • ► ' USE SOLID WOOD Y� !
: ' t . , Ei.aw("••' -
'• • .. ' i • _•' .• i •• • ' SUPPORT TO MAKE SILL
• = .. �. � � •.. •� LEVEL BY OTHERS e SW 44TH AVE.
• ► • •• ► • - t t14• a b ,-:. y FLORIDA 34474
CONCRETEMIA60NRY (MIN EMBEDMENT) �v' R�-. IN TALLA N DE T L THRU FRAME - MPR T
BY OTHERS 2 r� ° y��{w� . °+ _ PVC SINGLEHU ADE Pt 7nr2OOS
(MIN. EDGE DIST.) *I �'o = ( C aN', r, a .,
iE\ VERTICAL SECTION PROIN THIS
CWFlIIENTML • .:.� o. L . NO.:
THE INFORMATION CONTAINED N T11S IXIANINfi IS THE SOLE PROPEIfriY• -- .:� - � � 8100 NITS CWS-155
7 FRAME (MASONRY) WINDOW SYSTEMS. RAC. ANY R�ROp()CTWN N PART OR AS A IMiOLEL FL A 66Z I- 0 : . L
WRITTEN PEAA•551ON OF CUSTOM WINDOW SYSTEMS. RTC. IS PRO ,,. ,. - � A ' 7 OF 6
4
SHEATHS
BY OTHffI
EXTERIOR FINISH
BY OTHERS
CAULK BEHIND FIN
BY INSTALLER
WINDOW WRAP
9Y INSTALLER
PERIMETER CAULK
BY INSTALLER
WINDOW FRAMI
HEAD
2 BY WOOD BUCK
BY OTHERS
INSTALLATION ANCHOR,
INS WOOD SCREW
1/4" MAX SHIM
(SEE NOTE 2 & 3ON SHT. 2)
2 BY WOOD BUCK
BY OTHERS
INSTALLATION ANCHOR,
"WOOD SCREW
1 112"
(MP EMBEDMENT)
SHEATHING
BY OTHERS 1 • . d
d• T•V
d• t••
EXTERIOR FINISH
�-j 1/4' MAX SHIM
f (SEE NOTE 2 & 3 ON SHT. 2)
WINDOW FRAME
JAMB
WINDOW FRAME
SILL
4
SHEATHS
BY OTHffI
EXTERIOR FINISH
BY OTHERS
CAULK BEHIND FIN
BY INSTALLER
WINDOW WRAP
9Y INSTALLER
PERIMETER CAULK
BY INSTALLER
WINDOW FRAMI
HEAD
2 BY WOOD BUCK
BY OTHERS
INSTALLATION ANCHOR,
INS WOOD SCREW
1/4" MAX SHIM
(SEE NOTE 2 & 3ON SHT. 2)
2 BY WOOD BUCK
BY OTHERS
INSTALLATION ANCHOR,
"WOOD SCREW
1 112"
(MP EMBEDMENT)
SHEATHING
BY OTHERS 1 • . d
d• T•V
d• t••
EXTERIOR FINISH
�-j 1/4' MAX SHIM
f (SEE NOTE 2 & 3 ON SHT. 2)
WINDOW FRAME
JAMB
WINDOW FRAME
SILL
BY OTHERS
WINDOW WRAP
BY INSTALLER
CAULK BEHIND FIN
BY INSTALLER
PERIMETER CAULK
BYINSTALLER
CAULK BEHIND FIN
1W MAX SHIM
(SEE NOTE 2 & 3 ON SHT. 2) L�1
HORIZONTAL SECTION
BY INSTALLER
LAB
FIN (WOOD)
PERRAETERCAULK
•�
BY INSTALLER
2 BY WOOD SUCK
•
314
BY OTHERS
•••
WINDOWWRAP
,t••
BY INSTALLER
; y
INSTALLATION ANCHOR,
•' ••
IM WOOD SCREW
-
EXTERIOR FINISH
•'r
BY OTHERSiL
ti •/ 800
,.-i.
SHEATHING-'
(INN EMBEDMENT)
BY OTHERS
'-
"-d N} �'•
VERTICAL SECTION
Y.."
IN (WOOD)
PROPMETARY MO COMFIOENTNL :-Is
THE INFORMATION CONTAINED IN T4S DRAWIND IS THE SOLE PROPERTY
" �S'1LIOB8w'1=0cvMM•MI .<.
WINDOW SYSTEMS. INC, ANY REPRODUCTION IN PART OR AS AYM/OLLEENMST�HOU7
FL PE.,Ib.A2614
CUSTOM PERMISSION OF CUSTOWIDOW SYSTBIS. INC. 6 PROFY&TED.
•ditBlf(ti��A`
SINGLE HUNG ELEVATION (IMPACT) PVC IMPACT REOUIR MENT:
(SHOWN W/ DIFFERENT OPTIONS) 1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH THE FLORIDA BUILDING
CODE, CURRENT EDITION
53 118' S3 t/6'
MAX. OVERALL MAX OVERALL 2. GLAZING OPTIONS: (SEE SHEET 3)
FLANGE WIDTH FLANGE WIDTH
51 7/r MAX. UNIT WIDTH 3. CONFIGURATIONS'. "O/X".
51 7/r MAX, UNIT WIDTH
47 11/1W GLASS OLO 41 11116' GLASS DLO 4. DESIGN PRESSURE RATING: (SEE TABLES -SHEET 3)
- i F__ F I -_ -NEGATIVE DESIGN LOADS BASED ON TESTED PRESSURE AND GLASS TABLES ASTM E 1300..
691re-POSITIVE DESIGN LOADS BASED ON, TESTED PRESSURE, WATER INFILTRATION TEST PRESSURE AND
76' MAX GLASS TABLES ASTM E 1300.
MAXOVERALL 7 O 3GLA S OVERALL 331 5. ANCHORAGE. THE 33 1/3% STRESS INCREASE HAS NOT BEEN USED 1N THE DESIGN OF THIS PRODUCT. SEE
FLANGE
FLANGE
DLO HEIGHT 114• Duo SHEETS 6-8 FOR ANCHOR DETAIL.
74 3/4• MAX 6. SHUTTERS ARE NOT REQUIRED.
MAX HEIGHT
HIGHT 7. ALL FRAMES AND VENTS FULLY WELDED. SMALL JOINT SEAM SEALANT USED AT FIXED MEETING RAIL AND
UNIT
E30 1/2"
3r 33 11116' MAX 27 3116' JAMB.
MAX. GLASS SASH GLASS
SASH X DLO HEIGHT A �O B. REFERENCE TEST REPORTS: NCTL-210-3168-2 , NCTL-2103168.2A , NCTL-210.31663 , NCTL-210-3168�
HEIGHT I lr
_____IL 9. SERIES ! MODEL DESIGNATION SHS100.
45 Illy
45111 GLASS DUD 10. WOOD BUCK OR STUD FRAMING TO BE DESIGNED AND ANCHORED TO PROPERLY TRANSFER ALL LOADS TO
GLASS DLO STRUCTURE, BUCK AND FRAMING IS RESPONSIBILITY OF ARCHITECT OR ENGINEER OF RECORD.
7 5 HI SASH ORIEL
7 11. THE DESIGNATION X AND 0 STAND FOR THE FOLLOWING' X =OPERABLE SASH, O =FIXED SASH
EQUAL SPLIT 12. SECTION CALLOUTS FROM EQUAL SPLIT ELEVATION APPLY TO ALL ELEVATIONS IN A SMRLAR LOCATION.
3r MAX OVERALL
53 I/r 53 Its" FLANGE WIDTH
MAX. OVERALL MAX. OVERALL 35 W4" MAX UNIT WIDTH
FLANGE WIDTH FLANGE WIDTH 31 9MG' GLASS OLD
51 7/8' MAX. LINIT WIDTH 51 71r MAX. UNIT WIDTH
47 11116' GLASS DLO 47 1 N16" GLASS OLD 6r
-7MAX
63618" 63Stir OVERALL O 27!
FLANGE GLASS
OERALL 33 Irr OVERALL. 33-W HEIGHT 61 3t4" OLO
FLANGE O GLASS FLANGE O GLASS MAX
HEIGHIT 52 31r DNA HEIGHT 62 1116' OLO UNIT
MAX MAX HEIGHT 30•
UNIT UNIT MAX G273116•
HEIGHT SHT SASH
24 S?r �/ 21 3/8" 24 511Ir 21• HEIGHT OLD
SASH x GLASS MAX. X GLASS
SASH
HEIGHT 4 OLOHEIGHT /� DLO
21 I&Ir
GLASS DLO
GLASS O GLASS ao E UAL SP IT UPDATED PER NEW FBC REQUIREMENTS 07/07/08
60/40 SPLIT ORIEL 4 HI SASH ORIEL
TABLE OF CONTENTS
GENERAL NOTES & ELEVATIONS.....I 44TH AVE.
e
ANCHOR SCHEDULE & NOTES .......... 2 ?- F' FLORIDA 34474
DP CHARTS & GLAZING DETAIL........3 •� `
SECTK)N VIEWS ............................. 4 ` .' 4 NOTES & EIII/ATIONS - IMPACT
EXTRUSIONS & B.O.M..................5 r , +. N �MQ s : 7p/2006
INSTALLATION DETAIL .............. .. 6-8 o • Ohl -. i' PVC SlINGLE ADE
PROMWTARYAW COMMOIEW"U. • �-b
THE INFORMATION CONTAINED IN TMSIIRAWMNo1s THE SOLE PR�4fM6TTOq _ LIMO OMAB-..a fl NITS .NO.: CWS-15S
WINDOW SYSTEMS INC. ANY REPRODUCTION N PART OR AS A TTff�� FL P 62514'
WRITTEN PERL•SFJON OF CUSTOM WINDOW SYSTEMS, INC. NS - • - . L A I OF 8
,� • c_ ,_r
SO 00.
.45•i/ell iyf•16{Pt\
SEE NOTE 2
1T
MAX. O.C. -7
(TYP.)
6"
AX
(T6yp) 1 1
9
MAX O.C.
(TYP)
INSTALLATION X
ANCHORS TYP.
4
ANCHOR LAYOUT- (FLAWX)
THRU FRAW & CLIP (MASONRY OPENING)
ISPECM FOR 75D-P )
4" 4"
MAX. MAX
4"
MAX
(TYP) f
w
MAX O.C.
(TYP)
r
MAX. O.C.
(TYP.)
-SEE NOTE
L
MAX
(TYP)
6'
MAX
(NIP)
Ir
MAX O.C.
X
4 INSTALLATION
ANCHORS TYP.
INSTALLATION
ANCHORS TYP.
ANCHOR LAYOUT - (FIN)
THRU NMIIM'i•IN IWW0 OPEN
(SPECIFIC FOR 750.P.)
SEE NOTE 2
ANCHOR LAYOUT - (FLANGE)
TNIAU FRAFAE & CU ()
(SPECIFIC FOR 67 5 D.P.)
NOTES:
1. INSTALL ONE ANCHOR AT EACH INSTALLATION LOCATION
2. SHIM AS READ AT EACH SET OF INSTALLATION ANCHORS USING LOAD BEARING SHIMS. MAX. ALLOWABLE SHIM STACK TO BE 1/4". USE
SHIMS WHERE SPACE GREATER THAN 1116" IS PRESENT.
3. LOAD BEARING SHIMS SHALL BE CONSTRUCTED OF HIGH DENSITY PLASTIC OR BETTER. WOOD SHM1S ARE NOT ALLOWED.
4. 3116" DNA. ELCO TAPCON MASONRY ANCHORS MUST BE OF SUFFICIENT LENGTH TO ACHIEVE A MIN. EMBEDMENT OF 1 114" INTO MASONRY
THRU FRAME OR THRU 1 BY WOOD BUCK INTO MASONRY. A MINIMUM EDGE DISTANCE OF 2 112" SHALL BE ACHIEVED.
5. 010 WOOD SCREW ANCHORS MUST BE OF SUFFICIENT LENGTH TO ACHIEVE A MIN. EMBEDMENT OF 1 318" INTO 2 BY WOOD BUCK.
6. 08 WOOD SCREW ANCHORS MUST BE OF SUFFICIENT LENGTH TO ACHIEVE A MIN. EMBEDMENT OF 1 1/2" INTO 2 BY WOOD BUCK FOR FIN
INSTALLATION
7. SEAL CORNERS WITH SMALL JOINT SEAM SEALANT.
S. ALL INSTALLATION ANCHORS MUST BE MADE OF A CORROSION RESISTANT MATERIAL OR COATING,
9. INSTALLATION ANCHORS SHALL BE IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS, AND ANCHORS SHALL
NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW, `L` '
10. INSTALLATION ANCHOR CAPACITIES FOR PRODUCTS HEREIN ARE BASED ON SUBSTRATE MATERIAL WITH THE FOLLOWING PROPERTIE2
A. WOOD - MINIMUM SPECIFIC GRAVITY OF G-0.42 '
S. CONCRETE - MINIMUM COMPRESSIVE STRENGTH OF 3,200 PS(.
C. MASONRY - STRENGTH CONFORMANCE TO ASTM C-90. GRADE N, TYPE 1 (OR GREATER). y
PROPRETMY MID CONRWNM - �� �of"
THE INFORMATION CONTAINED IN TMS O RAW1NG THE
E SOLE PROPERTY OF01IT
WINDOW SYSTEMS INC. AN/ REPRODUCTION IN PART OR AS A WHOLE VAT TI
E
WRTTEN PERMSSION OF CUSTOM W WDOW SYSTEMS. INC. IS PROMS 2 v
i
C '
4'
MAX (T
P
MAX (TIP)
6•
MAX O.C.
INSTALLATIO
ANCHORS TV
ANCHOR LAYOUT - (FIN)
THRU NNUNO FIN MOOD OPENING)
(SPECIFIC FOR 67.SO.P.)
TE 6
MOOMLARSIZ?'s IUMT - YWM DMVSMM
HOMINY tM
WIMTH
I"
GL.A$$
TYPE
27112
29112
31112
361/2
36l/2
41112
1 43112
47112
1 61112
13112
55112
69112
63112
66112
671/2
71112
74314
23112
A.B
+75/-75
-751-75
-751-75
+751-75
+7S/-75
+75/-75
+T51-75
+7S1-75
-751-75
+751-75
+751-75
•751-75
+67.51-67.5+67.5/-87.5+67.51-67.5+67.51-67.5+67.5/-67
27111
A,8
+75/-75
-751-75
+75/-75
+75/-75
+75/-75
+75/-75
+751-75
+75/-75
+751-75
+75/-75
+751-75
+751-75
+67.51-67.5+67.5/-67.5+57.5/-67.5+67.51-67.5+67.5/-67
29112
A,B
+751-75
+751-75
+751-75
+761.75
+751.75
+751-75
+751-75
+751-75
+751-75
+751-75
+751-75
+751-75
+67.5/-67.5+67.5/-67.5+87.51-67.5+67.51-67.5+e7.5/-67
31112
A,B
+75/-75
-751-75
+751-75
+751-75
+751-75
-751-75
+751-75
+751-75
+751.75
+751-75
-751-75
-751-75
+67.51-67.5
+67.5/-67.5
+67.51-67.5
+67.5/-67.5
+67.51-67
UV2
A.5
+75/-75
+751-75
+761-75
1 +75/-15
+75/-75
+761-75
+ISI-IS
+751-75
-751-75
+751-75
+75/-75
1 +751-75
+6751-67.5+67.51-671+57.51-67.5+67.51-67.5+67,51-67
39112
A. S
+67.51-67.5
+67.51.67.6
+6731-67.5
-67.51-675
+67.5/-67.5
+67.5/-67.5
+67.5/-67.5
+87.51-67.5
+67.5/-67.5
+67.5/-67.5
-67,51-67.5
+67.51.07.5
+67.51-67.5
+67.5/-67.5
+57.51-67.5
+57.5/-67.5
+67.51-87
41118
A, B
+67.51-67.5
+67.51-67.5
+67.5/-67.5
+67.51-67.5
+67.51-67.6
+67.51-67.5
+67.51-67.5
+67.51-67,5
+67.5/-67.5
+67.5/-67.5
+67.5/-67.5
+67.5/-67.5
+67.5/-67.5
+67.51-67.5
+67.51-67.5
+67.51-67.5
+47.51-67
43112
A, B
+67.5/-67.5
+67.51-675
+67.51-67.5
-67,51-67.5
+57.5/-67.5
+67.51-67.5
+67.5/-67.5
+67,5/-57.5
+67.51-675
+6751-67.5
+67.5/-E.5
+67.5/-67.5
+67.51-67.5
+67.51-67.5
+67.5/-67.5
+67.51-67.5
+67.51-67
47112
A, B
+67.5/-67.5
+67.61-67.5
+67.V-87.5
+67.51-87.5
-67.51-67.5
+67.51-67.5
+67.51-67.5
+67.5/-67.5
+67.51-67.5
+67.51-67.5
-67.51-67.5
+67.5/-67.5
+67.51-67.5
+67.51-67.5
+57.51-67.5
+67.5/-67.5
-67.51-67
glitz
A. B
+87.51-67.5
+87.5/-67.5
+67.5/-67.5
+E7.5/-67.5
+67.51-67,5
+67.51.67.5
+67.51-67.5
+67.51-67,5
+67,51-67.5
+67.51-67.5
+67.5/-67.5
+67.51-67.5
+67.5/-67.5
+67.51-57.5
+67.5/-67.5
+67.51-67.5
+67.51-87
COMMODITY sMo (Tip to M
HEKWtM
11910TH
(III
GLASS
TYPE
26
36 SA
6o 6A
66
63
T2
78
19118
A.5
+751-75
-751-75
-751-75
+T51-75
+751-75
+67.5l-67.5
+67.51-67.5
26112
A. B
+751-75
+751-75
+751-75
+751-75
+75/-75
+67.5/-07.5
+67.51-67.5
37
A,B
+751-75
+75/-75
+75/-75
+75/-75
+75/-75
+67.51.67.5+67.51-67.5
6314
A. B
+67.51-67.5
+67.51-67.5
+67,51-67.5
+67.51-67.5
+67.51-67.5
+67.51-67.5
+67.5/-67.5
314" OVERALL
W4" OVERALL
1/8' ANNEALED GLASS
1/r TEMPERED GLASS
5/1r AIRSPACE
5116" AIRSPACE
5 W LAMINATED
SI16' LAMINATED
11r ANNEALED GLASS
Itr ANNEALED GLASS
3132' DUPONT PVS INTERLAYER
3/32" DUPONT PVB INTERLAYER
I/6• ANNEALED GLASS
Itr ANNEALED GLASS
NOTE:
1.11F SIM INTENDED IS NOT SHOVYN,USE NEXT
LARGER SIZ
.
A UPDATED PER NEW FBC F
t _•
GLASS TYPE A GLASS TYPE B
��:�
r •�
000 SW 44TH AVE.
�..
o -
,ALA, FLORIDA 34474
,�"•
_
�' .
•
DP CHART & GLAZING D T
,"t`-
o
-
_
:saVc �N!FII•
PVC SINGLE HUN
PROPNETARY MID CONi06NTML
THE
,.
L ROQ
8100
THE INFORMATION CONTAIED IN THIS DRAWING IS SOLE
WINDOW SYSTEMS. INC. ANY REPRODUCTION IN PART OR AS A
•,
- FL P13 NO. 62514
_
WRITTEN PERMISSION OF CUSTOM WINDOW SYSTEMS. INC. IS
a-
�.
` 7n12000
L w NO.: CWS-155
A 3OF8
0 2010 BY DESIGN STYLES, INC. ALL RIGHTS RESERVED. ALL IDEAS, DESIGNS, ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THIS DRAWING AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE THE ORIGINAL AN UNPUBLISHED WORK OF DESIGN STYLES, INC. AND THE SAME MAY NOT BE DUPLICATED, USED OR DISCLOSED TO ANY PERSON, FIRM OR CORPORATION FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION OF DESIGN STYLES, INC.
T
0
0
D
-
W
6
'0 O
C_
m
n
r-
m
n
C
0-0 --1my
D
D O C
Z
m
0 ca
=n
m
>
Z
Cl
(� O
/L
V/
O
m
-4
!7
0
111111111mma
The Seven Springs - Keystone Challenge Fund
38826 4th Ave. Zephyrhills, FL 33542
PREPARED FOR:
Pasco County Community Development Division
Project: #0737
O. n.1
a o
v v d
•G N N �
'0 V
IO 0 w
s ^ w C o-
n ID A w
o -N• N LL-n q IO
V 10
(M^
VI
r••Ir
3 CC 6 0 .4 o KtgM TFOM every angle:- V A7
The Seven Springs - Keystone Challenge Fund
38826 4th Ave. Zephyrhills, FL 33542
PREPARED FOR:
Pasco County Community Development Division
Project: #0737
O. n.1
a o
v v d
•G N N �
'0 V
IO 0 w
s ^ w C o-
n ID A w
o -N• N LL-n q IO
V 10
(M^
VI
r••Ir
3 CC 6 0 .4 o KtgM TFOM every angle:- V A7
IHERMAITRU
THERMA TRU DOORS
1 1 8 INDUSTRIAL DR., EDGERTON, OH 4351 7
TEL. (41 9)298-1 740
"SMOOTH STAR" "FIBER CLASSIC"..
"CLASSIC CRAFT" & "CLASSIC CRAFT RUSTIC"
GLAZED FIBERGLASS DOOR
INSWING / OUTS WING
'IMPACT"
GENERAL NOTES
1. This product has been evaluated and is in compliance with the 2007 Florida Building Code (FBC)
structural requirements excluding the "High Velocity Hurricane Zone" (HVHZ).
2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment to base
material shall be beyond wall dressing or stucco.
3. When used in areas outside of the "HVHT'requiring wind borne debris protection this product
complies with Section 1609.1.2 of the 2007 FBC and does not require an impact resistant covering.
This product meets missile level "D" and includes Wind Zone 4 as defined in ASTM E1996.
4. For 2x stud framing construction, anchoring of these units shall be the same as that shown for 2x
buck masonry construction.
5. Site conditions that deviate from the details of this drawing require further engineering analysis by a
licensed engineer or registered architect.
TABLE OF CONTENTS
SHEET #
DESCRIPTION
1
Typical elevations, design pressures & general notes
2
Door panel construction details & glazing detail "Smooth Star'
3
Door panel construction details & glazing detail "Fiber Classic"
4
Door panel construction details & glazing detail "Classic Craft & Classic Craft Rustic"
5
Horizontal cross sections
6
Vertical cross sections
7
Buck and frame anchoring - 2X buck masonry construction
8
Frame anchoring - 1 X buck masonry construction
9
Bill of Materials & Components
V MIN. FROM 1" MIN. FROM
MASONRY EDGE MASONRY EDGE —
(TYP.) (TYP.)
L
0
'u
1 VERTICAL CROSS SECTION
6 Inswing configuration
50 60
40 32 1
z a 33
�C
CN
D D e D p
D p e D
e p D
D N D
2-1/2" MIN. FROM 2-1/2" MIN. FROM
• • MASONRY EDGE MASONRY EDGE --
(TYP.) (TYP.)
3 VERTICAL CROSS SECTION
6 Inswing configuration
FRAME WIDTH
36.W' MAX.
PANEL WIDTH
i
/
�_
_0
ut w
at Z
Q
oIL
X
O
i
N
00
"SMOOTH STAR", "FIBER CLASSIC"
"CLASSIC CRAFT' & "CLASSIC CRAFT RUSTIC"
ING
INSWING
37.75" x 82.0W
21.00" x 63.25"
+47,0
-53,0
OUTSWING
37.75" x 80.62"
21.00" x 63.25"
+50,0
-50.0
2-1/2" MIN. FROM 2-1/2" MIN. FROM
MASONRY EDGE MASONRY EDGE
(TYP.) (TYP.)
INTERIOR
2 VERTICAL CROSS SECTION
6 Shown w/1 X sub -buck substituting
concrete screws for wood screws per
Section 1714.5.4.2 of the FBC
EXTERIOR INTERIOR
50 60
z 18
40
E E
�- W
D
p o pD e
p D e e e
D e p D
e e D D p
D p
D e
2-1/2" MIN. FROM 2-1/2" MIN. FROM
MASONRY EDGE MASONRY EDGE — —
(TYP.) (TYP.)
4 VERTICAL CROSS SECTION
6 Outswing configuration
Z
— W
F
O
Off �
Z'� 1
V tn
r, M CM
-J Of W
W
6
O
F
z 0 oz
z
u of
F = O C
W
-' a t0 w +.
M >�? 0 o
ti
m o 0
o in
m U N a
(= z o
y z C
m
0 o -0
3
0. 6 o 0
_
aM (I a- M
v
a
o
y �
0
3
Et
�. U
u
0
0
�o
Z
�
W
oQ
D:
O Z
Lq
q(CD
J
1
w
WW
�N
W
QLO
VCk-
ow
o
a
O
a
CL
�11
DATE: 4117108
SCALE: N. T. S.
DWG. BY: AL
CHK. BY: WWH
DRAWING NO.:
FL-7347.1
SHEET 1 OF 9
e
0
3
u�
M
mM u00i
c
U M
z
toC\Z 7t
vi L �_
W
6 O
0 °i
o z z
c vO/i
o Li
N > M
0 .,
0
z M
0 C o
m U N ••
6 L
-0 Z x0 z
O
e �mi'
�w 3
a. JCi o
oU -
aMaLamo
E
L
t� U
3
O
0
a
o:
0
0
o
N
�
O
C �
V W
I O
w
5
1= V)M
M
W
o`
LAJ
Wm
d
U
U
0:
O
Q.
DATE: 4/ 17 08
SCALE N.T.S.
DWG. BY: AL
CHK. BY: WWH
DRAWING NO.:
FL— 7347.1
SHEET 6 OF 9
D °
° D
17
°
w
00
U_ >-
:z Z
C O — D
D
°
D
D°
w'n
V D
D
O W p °
U_>�
Z z D
0—
V) o
Q °
D
1-1/4" MIN.
EMB. (TYP.)
1 HORIZONTAL CROSS SECTION
§ Inswing configuration
MASONRY
OPENING
2X BUC
BUCK ANCHORING
NOTES:
INTERIOR
EXTERIOR
4„
LIVID. 11 Ir.)
HORIZONTAL CROSS SECTION
Shown w/1 X sub -buck substituting
concrete screws for wood screws per
Section 1714.5.4.2 of the FBC
HINGE JAMB
N
W W
to z Z
C14_
bLO
Inswing configuration
MASONRY
OPENING
FRAME
ne
LU
2X BUCK Lo U
F SEE NOTE 2 2 0
a 1 SEE NOTE 2
v
Q ° 1
< v
a v a V
o ' p
114" Elco Concrete screws anchoring 2x buck require a minimum 1" clearance to masonry edges, a 1-1/4" minimum embedment and a
minimum 4" clearance to adjacent concrete screws. Substitution of equal concrete screws from a different supplier may have different
edge distance and center distance requirements. Concrete screw locations at the comers may be adjusted to maintain the minimum
edge distance to mortar joints. If Concrete screw locations noted as 'MAX. ON CENTER" must be adjusted to maintain the minimum
edge distance to mortar joints, additional Concrete screws may be required to ensure the maximum on center dimension is not
exceeded.
2. 114" ITW concrete screws anchoring frame and/or sill require a minimum 2-112" clearance to masonry edges, a V 114" minimum
embedment and a minimum 3" clearance to adjacent concrete screws. Substitution of equal concrete screws from a different supplier
may have different edge distance and center distance requirements. Concrete screw locations at the comers may be adjusted to
maintain the minimum edge distance to mortar joints. If Concrete screw locations noted as 'MAX. ON CENTER" must be adjusted to
maintain the minimum edge distance to mortar joints, additional Concrete screws may be required to ensure the maximum on center
dimension is not exceeded.
FRAME ANCHORING
Masonry 2X buck construction
HINGE DETAIL
mM
N
M
Z M
0
r,c
\
W
N
0rn
oz
z
C
O C
0
W
.~,J tp
:P
0.
ZO M ao
O C
io
m UN••
ny
`0
Z p z
O Q
0
`o
V.
3
c,0
aJp00
-
aM (L (L
M
o0
v
C
0
o ^,
`o 0
0
0
0
�N
JO
Lil
J
OO(n
r
o0
o:
LU
Q
U
U
0
0
� o
a
�
w'^
a V
O
Uf
zz�
O
w
o
Q
Z
D
v a
Q
DATE: 4117108
SCALE: N.T.S.
\
/j
DWG. BY: AL
CHK. BY: WWH
1-1/4"MIN.
EMB. (TYP.)
DRAWING NO.:
FL-7347.1
SHEET 5 OF 9
STRIKE JAMB
LATCH & DEADBOLT DETAIL
k
ko
O
Z M
5 m
r.
1i � W
, uIti
0oz
tt
�1'z
rN 0C
w
> M a o
0
En
z M
O-C"•
UN 0. 0
r
z 00 Z O
e 9m��i;
`0
3
a Cj o
_
M L. m0
M-
a. d (u
�°
n .0 0
E LL U
N Z
O
O
O
Z
C-)�
o=)
�
I
QOU
J
UJi
2mw
Lu
pQ�
LLQ
�
z�
U
O
QY
O
0
a
n
r
�
' a
o
u
LL
C,
Q
Z
( �
: 4 17 08
a
E N.T.S.
BY: AL
i C
BY: WWH
a
ZING NO.:
LL
FL-7347.1
i a
c a
T 7 OF 9
—
C
LL,
O
•U)
(D
•>
0
C
0
W
N
Ln
UCM
M
Q
O
>
_O
cn
O
>1
_
W
N
Q
C
U
j
w
�
.o
V /
<
E
O
._
,�
U
L
CL
N
Cn
006
ch
�
U
a)
O
v ,
n�
ISSUE DATE: 05/06/10
JOB CAPTAIN: JMG
SCALE: AS NOTED
CHECKED BY: JMG/PF
PROJECT NUMBER: 0737
PRODUCT
APPROVAL SHEET 02
[> NOTES
1. DOOR QUALIFIES FOR HVHZ USE.
2. FOUR SECTION 7' HIGH DOOR SHOWN. 8' HIGH DOORS HAVE
FIVE SECTIONS.
3. SECTION HEIGHT OF 20.812, 19.00 & 16.75 ARE AVAILABLE
AND MAY BE USED IN COMBINATION TO ACHIEVE
VARIOUS HEIGHT DOORS.
4. EMBOSSMENT PATTERN OF 14.50 X 20.375 SHOWN. ALTERNATE
PATTERNS OF 12.50 X 43.375 AND 12.50 X 20.375 MAY BE
USED. DOOR WITHOUT EMBOSSMENTS ALSO AVAILABLE.
5. TORSION SPRINGS SHOWN. EXTENSION SPRINGS AVAILABLE.
6. RATED DESIGN LOAD +45/-49 P.S.F.
7. USE THIS BRACKET, REF. P/N 405964-0003, ON 16' X 8' HIGH DOORS.
8. TESTED IN ACCORDANCE WITH FLORIDA BUILDING CODE
PROTOCOLS TAS 201-94, TAS 202-94. & TAS 203-94.
9. DASH NUMBERS REPRESENT VARIOUS SECTION HEIGHTS.
10. GALVANIZED STEEL SKIN SHALL CONFORM TO
ASTM 653, 37,000 PSI MIN YIELD STRENGTH,
DOOR SKIN MATERIAL SHALL BE GALVANIZED ACCORDING
TO ASTM A525 TO G90 OR AN EQUIVALENT SURFACE COATING.
11. JAMB LOAD CALCULATIONS:
(1/2 DOOR WIDTH)(1 FOOT OF HEIGHT)(DESIGN LOAD)
(8 FEET)(1 FOOT)(49 PSF)=392 Ib/FT OF HEIGHT.
12. JAMB FASTENER REQUIREMENT:
(1/2 DOOR WIDTH)(1 FOOT)(DESIGN LOAD)
(8 FEET)(1 FOOT)(49 PSF)=392 lb.
13. FOR ANCHORING INTO WOOD, USE ONE 5/16" LAG SCREW PER
TRACK BRACKET WITH 1 1/2" EMBEDMENT INTO S.Y. PINE OR BETTER.
14. IF ANCHORED DIRECTLY TO CONCRETE OR GROUT FILLED CONCRETE
BLOCKS OR THRU A 2x6 WOOD JAMBS. USE ONE 5/16" POWERS LOK/BOLT
PER TRACK BRACKET WITH 1 1/2" EMBEDMENT INTO CONCRETE OR BLOCK.
15. DOUBLE STRAPS AT END STILE AND STILE LOCATED
AT MIDPOINT OF DOOR WIDTH.
PANEL
SECTION
WEATHERSE .�
SECTION "C-C"
SCALE: 1/2
2" X 6" WOOD JAMB
2" X 4" WOOD JAMB
3 1/8
OR EQUIVALENT
„D R
HORIZONTAL TRACK
& COUNTERBALANCE
I
OPTIONAL SPLICE IN
HORIZONTAL TRACK ATTOP
r
OF RADIUS964-0003„D„4-0003
7
405964-0003
IINUS1 "G�FX
1�® ( 615
55
45
F046450-000332
22
I
404043-0006 -�
TYP 4 PLACES
066341-0006
TYP 2 PLACES
404043-0005
TYP 4 PLACES
066341-0006
TYP 2 PLACES
035-0001 & 4
0585831-0002
TYP 4 PLACES
404043-0004
TYP 4 PLACES
066341-0006
TYP 2 PLACES
` 401124-0001
�3✓ 061 166-000;
STANDARD TRACK DETAIL FOR 16'
SCALE: 1/16" = 1" SERIES 180 THRU 189
ARE EQUIVALENT CONSTRUCTION
END HINGE
TTOM FIXTURE
DETAIL "F"
SCALE. 1/4
(16' WIDE)
2" X 6" WOOD JAMB
2" X 4" WOOD JAMB
OR EQUIVALENT
SEE NOTES 15 & 16
DETAIL "E"
SCALE: 1 /8
?011ER �•968
2.093
VIEW "D-D"
2" TRACK
.090 THK VERTICAL
.090 THK (HORIZONTAL)
/-P/N 046450-0003
,r-- 1/4" TRACK BOLT
SCREW P/N 605879-0002
BOTH SIDES OF STRUT AT CENTER STILE,
TOP SIDE OF STRUT AT CENTER OF PANEL. CENTER STILE a8
P/N 408680-0004,5,E
HEADPLATE r
SPRING ANCHOR T
400735-0001
BRACKET TYP 9 PLACES
rSHAFT
REVISIONS
DE9CFWnON I DATE
HS-3 STRUT
TOP
FIXTURE
0
TUBE STRUT
AND STRAP
SEE
NOTE 2
END HINGE
n _
066590-0000
TYP 4 PLACES
06116E-0003
TYP2P C S
I,
IIIfIN IIIIIIJ
r24 GA. f�i4 ... . ... .
SECTIONS
,II'I
FA
EA
ICI
ICI
ICI
ICI
l�Ill�l'`'
IIA�
0-
:. .
'• 6' ""
��I�I
I'IMlil
lilllil
lilllil
I--;
1i.wi�
��I�I
�I�I�I
Sri--
I�I�I�I
I�III�I
I�Ir•�
1�ffl
'-1a'C-r-T7'ss-a'«Ta'r-7'•:'tT7'
SEE
16'-0" MAX il
...
SERIES 180 - 46.7 PSF WINDLOAD
WIDTH
CENTER STILE
END STILE
ROLLERS�
BRACKDOOR
STRUTS/SECT.
ROLLER
TRACK
VEnCAGE
JAMB -HT)
(# PER FTCAL
HARDWARE
16'
7
DEL W/END CAP
NO
TUBE & HS3
2" X 5/8
392
STD. & FIVY DUTY
2"•090"
D NOTES 3 3/4 --
.106 MIN
0 0 o 0
3 5/8 ?ART DIM"H"
_ _ J__ 7 1/2 Q NUMBER (REF)
0 Lo
0 0 o I 404043-0004 1.34
--� �- .10E MIN I 404043-0005 1.59
--� 2 7/ 16 . - I 404043-0006 1.84
404043-0007 2.09
P/N 066590-000. TOP FIXTURE 0
2 5/8 "H"
.070 MIN
noo
P/N 404043-XXXX. END HINGHEAVY DUTY 5/8" STEM
1 3/4" 1 7/8
3 5/16 MAX
7 1/2 .150 MIN. �--
0
O
0 0 2 1/2" H
Q o 1 11/32 6"
T -� -►- .108 MIN 0 0 REF
2 1/2 l-- 5/8 P/N 405964 & 046.450. BRACKET. SCAB iI
I o
P/N 400735-0001, CENTER HINGE PART. NUMBER "L" o 0
405964-0001 3-1/4"
046450-0003 4" D P/N 401124-009, BOTTOM FIXTURE (RIGHT HAND SHOWN
)
P/N 401124-001, BOTTOM FIXTURE (LEFT HAND)
1/8 � 3.50 � LENGTH =DOOR WIDTH - 1"
5 8
1 7/8 ` .055
P/N 400650-0003..ROLLED HS-3 STRUT
CL OF
EMBOSSED
PANEL
I
5625"
0 �
E� 0
5.125" 1.125" TYP
E--
.9375" TYP
DETAIL "G"
SCALE= 1/4"
THE LOUVER IS AN OPTIONAL FEATURE AND
MUST BE SPECIFIED BY DISTRIBUTOR
UUOK WIUIH
INTERIOR ELEVATION
SCALE: 1 /16"=1 "
ODC GENIE EQUIVALENCE CHART
CDC SERIES
GENIE SERIES
188
COS 300
189
GDS 30 R
--{ 1 7/8" THK.
SECTION "A -A"
SCALE: 1/4
3WN)
HT
OVERHEAD DOOR CORPORATION
., 0
2501 S. STATE HWY 121, SUITE 200
LEWISVILLE, TX 75067
LeROY G. KRUPKE, P.E. #36580
MIME
DATE
OPANNOWM'
IM DWANO AND/OR TECHNICAL KFORWIM ON WE
SWEE*EnavnOPEWOFO%lM DOOR mNVRAMN
ar Rs su rMa E IANED N FUWOlES FOR
EMrAHEosID Arm urmwt AsarMxs PORPass ONLY .
+wowYNOT 9EMM OUCEOORUSED TO UF=UK
ANYmNa DrS�am WWOM WIIHOUTHc 0�
POOMMON OF DYERNEAD DOOR CORPOPATM *OCN VAll
RELW.L and 91EhTAr ANY ME. -
a
.m
A,eNwcaYanwoEOR
Na
�ma„m�.N
�,a -,�
�r«�o�
aria•
w.y�rf.N,.yr ® TM
9RMMI sr:
G.J. MOORE
6/22/94
SERIES 180 RESIDENTIAL
STEEL DOOR,+45/-49PSF,
16'-0" MAX WIDTH{
MaoDM
N/A
CWMWD 9Y,
P. VESSELS
7/20/94
Mvnva
.,r.-
mol
®- 408804
APP= aN91:
NONE
UW OF MEASURE:
EACH
APPWM BY:
S. BOUCHER
7/20/94
SCALE' 3/8 ,HEer 1 OF 2-
END STILE WITH
OPEN END CAP a CENTER STILE END STILE WITH
P/N 408441-0007,8,9 P/N 408680-0004,5,6 ag CLOSED. END CAP Qg
P/N 408794-0001,2,3
I I FFTI 1 I I
REVISIONS
DESCMPMaN DATE
CENTER STILE
P/N 408680-0004,5,6 ag
SCREW P/N 605879-0002 �P/N 605879-0002 _
P/N 40 650- 003 P/N 40 650 00 3'
SECTION "B-B" SECTION "B-B'
STEEL STRUTS STEEL STRUTS
(16' WIDE DOORS) END STILES SHOWN IN SECTIONS "B-B" (16' WIDE DOORS)
18 ARE EQUIVALENT CONSTRUCTION
CENTER STILE END STILE WITH CENTER STILE
END STILE WITH P/N 408680-004,5,6 a9 CLOSED END CAP ag P/N 408680-0004,5,6 a9
OPEN END CAP
P/N 408441-007,8,9 9 P/N 408794-0001,2,3
I I I I I
2" �+- 4"�-LENGHT= DOOR WIDTH - 1" - +� / I I / I I I I I 1
SCREW SCREW
__-__ - P/N 605879-0002 P/N 605879-0002
BE STRUT 607935-0001 TUBE STRUT 607935-0001
SECTION "G-G" AND STRAP 405831-0002 SECTION G-G AND STRAP 405831-0002
------- ----- - STEEL STRUTS EACH CENTER STILE STEEL STRUTS EACH CENTER STILE
(16' WIDE DOORS) (16' WIDE DOORS)
.083 15 END STILES SHOWN IN SF•Q'fj,QNS "G-G"
ARE EQUIVALENT CONSTRUCTION
P/N 607935-001, STRUCTURAL TUBING, RECTANGULAR. .083 THK.
5/8 DIA 9 1/2 REF
REF 7/16
4-
0 o 0 1/16" 1
OTHROW4.00 �3/4
ET2
� 1 13/16 DIA
4 5/8" o REF -Li
o
P/N 066341-0005. ROLLER ASSY, 2" TR-5 W/ 5/8" STEM 2.00
Tr -P/N 405831-0002 STRUT STRAP
1.06 16 GA, (.060) GALV. STEEL
P/N 061601-0000 SLIDE LOCK AS SY 47 REF
REF
�-- 1.81 DIA
REF i
I--- 5 1/8"� 1 3/4" A OVERHEAD DOOR CORPORATION
REFS 2501 S. STATE HWY 121, SUITE 200 7
2 3 8" LEWISVILLE, TX 75067
o �• / H
P/N 06116E-003. ROLLER AgSy 2" TR-3 W/ 7/16" STEM
0 LeROY G. KRUPKE, P.E. #36580
.108 MIN 'Ross me
sPEof•D r. DATE ORAVONOSERIES
TRLE
THE atw m Arm/OR TEE MAL NFDRDAMON ON mE D.asONs Me N naes. m °1LLi1S• aRARN eY: SEfiIES 180 RESIDENTIAL
SHM E THE PROPM OF D.sMHFAD mart OORPOUT N ow" •m . sf',.gPud ryw o 7Ofi� G.J. MOORE • 6/22/94 STEEL DOOR. +45/-49 PSF,
P/N 405964-0003. BRACKET. SCAB JOIN T OR nS SUBSIDDRY ANO IS LOANED N COWO MCE FOR wtETau � RY; 16'-0" MAX WIDTH
EMONEMC AND WRML ASSM&MCE PURPOSES ONLY,
ANO DAY NOT BE REPRODUCED ON USCOTo uMWFAMM n m u s,.Ae�mi maroN N/A P. VESSELS - 7/20/94 oRAWNO
ANYmNO 019MOSED HEREON WUWfT THE DFMS a, a so do.mt . V,P mmam ®- 408804
P004SMON OF OVU* Ml DOOR CORPODATCH WHCH WY m. a mf aw mc.mram AMMO MMSH: MR OF YEAS M AFPROVm m^
REML THS 94M AT MY THE NONE EACH S. BOUCHER - 7/22/94 . 3 g ;w 2 OF 2
L.L
10
�>
0
ni
cu
E
M
U
M
�
LL
O
a�
oZ0
C
>
cl)`
co
Q
W
4_I
�
\/
N
U
RZ.
�
�
• O
V♦
E
E�
O
.0
U
L
CL
CV
�
c:
O
(1)
U
>
n
W
O
c//)�
v /
,
W
i..�
1
ISSUE DATE: 05/06/10
JOB CAPTAIN: JMG
SCALE: AS NOTED
CHECKED BY: JMG/PF
PROJECT NUMBER: 0737
PRODUCT
APPROVAL SHEET 03
I. - - __—J - 11 ._ 1
M I A M I•DADE
BUILDING CODE COMPLIANCE OFFICE (BCCO)
PRODUCT CONTROL DIVISION
NOT!rr r-IF :_'.CC_EPTtti`;CE (NON
GAF Materials Corp.
1361 Alps Rd.
Wayne, NJ 07470
MIAMI-DADE COUNTY, FLORIDA
METRO-DADE FLAGLER BUILDING
140 WEST FLAGLER STREET, SUITE 1603
MIAMI, FLORIDA 33130-1563
(305) 375-2901 FAX (305) 375-2908
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. .
The documentation submitted has been reviewed by the BCCO and accepted by the Building Code and Product
Review Committee to be used in Miami Dade County and other areas where allowed by the Authority Having
Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The BCCO (In Miami Dade County) and/or the
AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality
assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur
the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or
material within their jurisdiction. BCCO reserves the right to revoke this acceptance, if it is determined by BCCO
that this product or material fails to meet the requirements of the applicahle huildim, code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code,
including the Hilgh Velocity Hurricane Zone.
DESCRIPTION: Timberline 30
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no
change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any
product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply
with any section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by
the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall
be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors
and shall be available for inspection at the job site at the request of the Building Official.
This NOA renews and revises NOA #05-1115.09 and consists of pages 1 through 4.
The submitted documentation was reviewed by Alex Tigeerra.
1
ROOFING SYSTEM APPROVAL
Category: Roofing
Sub -Category: 07310 Asphalt Shingles
Materials Dimensional
Deck '1'ype: Wood
1. SCOPE
This revises GAF Timberline 30 as manufactured by GAF Materials Corp described in Section 2 of this
Notice of Acceptance.
2. PRODUCT DESCRIPTION
Product Dimensions Test Product Description
Specifications
Timberline 30 13 L/4"x 393/8" TAS 110 Fiberglass reinforced heavy weight asphalt
roof shingle, with a laminate profile
3. EVIDENCE SUBMITTED:
Test Agency
Test Identifier
Test Name/Report
Date
Underwriters Laboratories, Inc.
TAS 107
OINK45803
04/13/94
Center for Applied Engineering
TAS 100
257989
04/01/97
Center for Applied Engineering
ASTM D3462
257989
05/13/97
PRI Asphalt Technologies, Inc.
ASTM D3462
GAF-101-02-02
11/02/05
PRI Asphalt Technologies, Inc.
TAS 100
GAF-044-02-01
01/13/04
PRI Asphalt Technologies, Inc.
TAS 100
GAF-101-02-01
11/09/05
PRI Asphalt Technologies, Inc.
TAS 100
GAF-116-02-02
03/23/06
Underwriters Laboratories, Inc. TAS 107 04NK04273 02/20/04
Underwriters Laboratories, Inc. Modified ASTM D3161 05CA42840 11/11/05
Underwriters Laboratories, Inc. TAS 107 06NK05159 08/09/06
Underwriters Laboratories, Inc. ASTM D3462 06NK05159 08/09/06
4. LIMITATIONS
4.1 Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials
Directory for fire ratings of this product.
4.2 Shall not be installed on roof mean heights in excess of 33 ft.
4.3 All products listed herein shall have a quality assurance audit in accordance with the Florida
Building Code and Rule 913-72 of the Florida Administrative Code.
5. INSTALLATION
5.1 Shingles shall be installed in compliance with Roofing Application Standard RAS 115.
5.2 Flashing shall be in accordance with Roofing Application Standard RAS 115
5.3 The manufacturer shall provide clearly written application instructions.
5.4 Exposure and course layout shall be in compliance with Detail 'A', attached.
5.5 Nailing shall be in compliance with Detail 'B', attached.
6. LABELING
6.1 Shingles shall be labeled with the Miami -Dade Logo or the wording "Miami -Dade County
Product Control Approved".
7. BUILDING PERMIT REQUIREMENTS
�)Ultliluo pCl'1111L _>all:� 'oC ICCO�l:li),,I;ICCI by' COple� of tl1C i1O14'lll":
7.1.1 This Notice of Acceptance.
7.1.2 Any other documents required by the Building Official or the applicable code in order
to properly evaluate the installation of this system.
8. MANUFACTURING PLANTS
8.1 Tampa, FL
8.2 Michigan City, IN
8.3 Mobile, AL
DETAIL A
NOA No.:06-1211.02 NOA No.:06-1211.02 o NOA No.:06-1211.02
_ Expiration Date: 02/21/12 — Expiration Date: 02/21/12 — Expiration Date: 02/21/12
Approval Date: 02/08/07 ' Approval Date: 02/08/07 Approval Date: 02/08/07
Page 1 of 4 Page 2 of 4 Page 3 of 4
DETAIL B
!' faFterers 72" -- 7
I
31
4 1 1
_
1
81 " ill
4
I
El El E:].-.
- -
5-
L
1 /i2"
T----
Front Side (Maximum Slope 12:12)
Front Side (Maximum Slope 21:12)
Tab Sealant
1
211 i
Back Side
END OF THIS ACCEPTANCE
Release
Tape
7
5/8"
l
Release
Tape
3/8°
i
NOA No.:06-1211.02
Expiration Date: 02/21/12
Approval Date: 02/08/07
Page 4 of 4
C
LL
0
�
•i
^C
W
C:
C
a)
E
Jc
�
U
M
CL
J
L.L
0
a)
uj
O
i
0
C)
CM
N
C
a.
•°'
O
ate-+
0
cc
L
C*
-�
Cn
CO
M
C:
C
0
a)
U
^>
W
O
V
Cn
J
^,
^^CU
9-M
ISSUE DATE: 05/06/10
JOB CAPTAIN: JMG
SCALE: AS NOTED
CHECKED BY: JMG/PF
PROJECT NUMBER: 0737
PRODUCT
APPROVAL SHEET 04
PA