Loading...
HomeMy WebLinkAbout39601 Kennedy AveCALIFORNIA LAW GROUP LLC TRUSTEE VICINITY MAP �^ KENNEDY AVE DRIVING DIRECTIONS FROM:14236 6th St, Dade City, FL 33523 Head south on 5th St. toward Live Oak Ave. Take US-301 and Wire Rd to 6th Ave/County Rd in Zephyrhills. Continue on 6th Ave/County Rd. Drive to Kennedy Ave. TO: 39601 Kennedy Ave Zephyrhills, FL 33542 Destination is on the left PROJECT DESCRIPTION SCOPE OF WORK EXISTING FOUR BEDROOMS, ONE BATHROOM BLOCK FRAME RESIDENCE WORKS UNDER THIS PERMIT TO REMODEL INTERIOR FLOOR PLAN IN ORDER TO CONVERT EXISTING UTILITY STORAGE INTO A MASTER BATHROOM AND LAUNDRY ROOM. NEW PLUMBING FIXTURES PROVIDED. WINDOWS AND DOORS TO BE REPLACED WITH 2017 FBC (6TH EDITION) COMPLIANCE SIZE BY SIZE. AC UNIT CHANGE OUT. NEW ELECTRICAL INSTALLATION AND NEW APPLIANCES PROVIDED. NEW PLUMBING INSTALLATION AND FIXTURES. NO NEW FOUNDATION, ROOFING OR SITE WORKS UNDER THIS PERMIT. HANDICAP REQUIREMENTS FACILITY IS DESIGNED TO ACCOMODATE DISSABLED ACCESS. OTHER REQUIREMENTS PROPERTY IS SERVED BY CITY WATER AND SEWER. RESIDENCE REMODELING 39601 KENNEDY AVE ZEPHYRHILLS, FL 33542 SHEETINDEX SHEET DESCRIPTION DATE REV. 'I PROJECT INFORMATION � 2 EXISTING & DEMOLITION AND FLOOR PLANS 0 3 ELECTRICAL PLNA AND FRONT ELEVATION 0 4 NOTES 0 5 DETAILS 0 S SITE PLAN 0 0 0 0 0 0 DO NOT SCALE DRAWINGS CONTRACTOR SHALL VERIFY ALL PLANS & EXISTING DIMENSIONS & CONDITIONS ON THE JOB SITE & SHALL IMMEDIATELY NOTIFY THE ENGINEER IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE WORK OR BE RESPONSIBLE FOR SAME. ***CAUTION*** THE UTILITIES SHOWN HEREON ARE FOR THE CONTRACTOR'S CONVENIENCE ONLY. THERE MAY BE OTHER UTILITIES NOT SHOWN ON THESE PLANS. THE ENGINEER ASSUMES NO RESPONSIBILITY FOR THE LOCATIONS SHOWN AND IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY ALL UTILITIES WITHIN THE LIMITS OF THE WORK. ALL DAMAGE MADE TO EXISTING UTILITIES BY THE CONTRACTOR SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR. PROJECT SUMMARY SITE NUMBER: 2018-0102 SITE NAME: CALIFORNIA LAW GROUP LLC TRUSTEE LOCATION ADDRESS: 39601 KENNEDY AVE ZEPHYRHILLS, FL 33542 FOLIO: 000000-0000 PARCEL ID.: 12-26-21-0280-00000-0070 OCCUPANCY TYPE: 0100 SINGLE FAMILY R ZONING CLASSIFICATION: REC-3 ZONING JURISDICTION: CITY OF ZEPHYRHILLS PROPERTY OWNER: CALIFORNIA LAW GROUP LLC TRUSTEE P.0 BOX 341077 TAMPA, FL 33694 ENGINEER: MARK RICHTER, PE RICHTER ENGINEERING, INC. 3014 US Hwy 301 N — Suite 700 Tampa, FL 33619 PH. 813-754-8148 FAX 813-752-0512 richter@engineer.com GENERAL NOTE CONTRACTOR TO CONSTRUCT THE PROJECT TO CONFORM WITH THE FLORIDA BUILDING CODE 6th EDITION (2017). ALL MEASUREMENTS ARE TO BE CONFIRMED PRIOR T0, DURING, AND AFTER CONSTRUCTION. ANY ERRORS ARE TO BROUGHT TO THE ENGINEER � AND OWNER'S ATTENTION. CONTRACTOR TO VERIFY THE PRESENCE OR LACK OF EXISTING BURIED UTILITIES. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR EACH SUBSEQUENT SUBCONTRACTOR'S FINISH 'I PRODUCT. CARE SHALL BE TAKEN SO AS TO NOT DAMAGE PREVIOUSLY FINISHED WORK. REVIEW BATE CITY of ZEPH F� 11L; $ PLAN 1=XAMINFF? i \ J � v _ �•w W _��rM--✓✓✓� A o i •• O iI Q W U W W O H w l— H J a aw�a 0 a.LO 0 Z Q w U M Z p w z p_ Z Z W o r O QC7�0 O d U,Zp? ww0(C a0 r m U C3p2w pwQor:z O CV U) O— cl z 6ya. w vn - Ucc p 0 W p O = ZwmU UI—O �wz0 O =0}� a LU �F-�z Q Lcn 0 7J�CC ro W Z rrw> — cn —Ozcn Q a J s H E T N O w w Cn D 1cJ J CND �. LL1 L M Z 0 0 Q J 0L ~ wU a CD z J � W �e 0 Q -o = LL Z Q MN Z W 0 0 LL oc � a Q CU rei \'Al 49'-7" 49'-7" EXISTING AND DEMOLITION PLAN SCALE 1 /4" = 1 FLOOR PLAN SCALE 1 /4" = 1, 6'-7" �7 10" 37151 10'-10" 375 I 5'-6" SQUARE FOOTAGE HEATED AREA 13GG 5f UST 1 10 5f PORCH 1 12 5f TOTAL AREA 1 588 5f LEGEND O EX15TING WOOD FRAME WALL ® CONCRETE BLOCK WALL ED TO BE DEMOL15HED NEW WOOD FRAME WALL 77 `X" STEP (5EE FROM BOTTOM * RIGHT) SQUARE FOOTAGE HEATED AREA 147G 5f PORCH 1 12 5f m X r- m m m X m DEMOLITION NOTES 1. VERIFY ALL DIMENSIONS AND ELEVATI❑NS BEFORE STARTING DEM❑LITION WORK, 2. PR❑VIDE TEMPORARY BRACING AND SH❑RING OF J❑ISTS AND BEAMS WHEN DEMOLISHING EXISTING WALLS, 3. ALL TERMITE AFFECTED AREAS AND/OR STRUCTURAL MEMBERS SHALL BE REPLACED WITH EQUAL OR BETTER STRUCTURAL NEW MEMBERS. 4. ALL DEM❑LISHING WORK SHALL BE PERFORMED IN ACCORDANCE WITH LOCAL LAWS AND REGULATIONS FOR SAFETY MEASURES AND C❑NSTRUCTION METHODS, 5, THE CONTRACTORS SHALL BE RESPONSIBLE FOR PROPER DISP❑SAL OF ALL DEMOLISHED MATERIALS AND EQUIPMENT, 6, ANY DEMOLITION THAT IS FOUND NECESSARY DURING THIS WORK AND THAT IS NOT NOTED IN THIS DRAWING SHALL BE INFORMED TO THE ENGINEER, Location min/max Horiz Distance From Windward Edge Oft 5 ft loft 20 ft Windward Roof Coefficient Normal to Ridge, CP Min -0.90 -0.90 -0.50 -0.30 Max -0.18 -0.18 -0.18 -0.18 Leeward Roof Coefficient Norma Ito Ridge,CP Min -0.90 -0.90 -0.50 -0.30 Max -0.18 -0. LB -0.18 -0.18 Roof Coefficient Parallel to Ridge, CP Min -0,90 -0.90 -0.50 -0.30 Max -0.18 -0.18 -0.1$ 1 -0.18 Structure_ Pressure Summary {Add Internal Pressure p,GC.,, or 9,,GC„, as Necessary Roof Figure 27.4-1 Neight,z K, qZ Walls Normal to Ridge Parallel to Ridge internal WW LW WW f LW Side WW LW Positive Negative 0 ft 0.57 26.3 psf 17.6 psf -9.3 psf 26.9 psf -1S.4 psf Min: 19.8 psf Min: -19.8 psf Min: -19.8 psf 4.7 psf -4.7 psf 1 ft 0.S7 26.3 psf 17.6 psf 26.9 psf 4.7 psf 2 ft O.57 26.3 psf 17.6 psf 26.9 psf 4.7 psf 3 ft 0.57 26.3 psf 17.6 psf 26.9 psf 4.7 psf 4 ft 0.57 26.3 psf 17.6 psf 26.9 psf 4.7 psf 5 ft 0.57 26.3 psf 17.6 psf 2&9 psf Max: -4.0 psf Max: -4.0 psf Max: -4.0 psf 4.7 psf 6 ft 0.57 26.3 psf 17.6 psf 26.9 psf 4.7 psf 7 ft 0.57 26.3 psf 17.6 psf 26.9 psf 4.7 psf 8 ft 0.57 26.3 psf 17.6 psf 26.9 psf 4.7 psf 9 ft 0.57 26.3 psf 17.6 psf 2&9 psf 4.7 psf 10 ft 0.57 26.3 psf 17.6 psf 26.9 psf 4.7 psf STRUCTURAL DESIGN CRITERIA PER FLORIDA BUILDING CODE 6TH EDITION (2017) (FBC) DESIGN WIND VELOCITY (3-SEC GUST) 150 MPH RISK CATEGORY II IMPORTANCE FACTOR 1.0 BUILDING CATEGORY II WIND FXPnSIIRF R STRUCTURE TYPE ENCLOSED INTERNAL PRESSURE COEFFICIENT +/- 0.18 COMPONENTS AND CLADDING DESIGN WIND PRESSURES: SEE TABLES ROOF LIVE LOAD 20 PSF ROOF DEAD LOAD 10 PSF FLOOR LIVE LOAD 40 PSF FLOOR DEAD LOAD (WOOD FLOOR TRUSSES) 15 PSF CONCRETE (AT 28 DAYS) 3000 PSI REINFORCING STEEL ASTM A615 GRADE 60 MINIMUM LAP -FOR No. 4-BARS = 20" - - No. 5 BARS = 25" No. 6 BARS = 30" No. 7 BARS = 35" STRUCTURAL STEEL ASTM A-36 LUMBER MINIMUM Fb 1150 PSI USE (MINIMUM) SOUTHERN PINE No.2 OR DOUGLAS FIR -LARCH No.2 FOR ALL STRUCTURES LOAD BEARING OR EXPOSED TO WIND SOIL BEARING PRESSURE (ASSUMED) 2000 PSF TO BE FIELD VERIFIED PRIOR TO PLACING OF FOOTING REINFORCEMENT OR CONCRETE POUR; NOTIFY DESIGNER IMMEDIATELY IF SOIL FAILS TO MEET REQUIREMENTS. STRUCTURAL DESIGN SHALL BE IN COMPLIANCE WITH CHAPTER 1609 OF FBC ALL WORK SHALL BE IN ACCORDANCE WITH THE FBC AND LOCAL ORDINANCES AND REGULATIONS. APPROVED PRODUCT LIST PRODUCT SUB MANUFACTURER STATE OF FLORIDA APPROVAL CATEGORY CATEGORY APPROVAL NUMBER DATE DOOR EXTERIOR DOOR JELD-WEN FL14111-R2 01/21/2015 Ply Gem WINDOW WINDOW Windows 14039-R2 04/25/2015 STRUCTURAL WOOD FL11473-R3 06/22/2015 COMPONENTS CONNECTORS SIMPSON FL10860-R3 06/21/2015 ROOFING ASPHALT FL10124-R19 10/13/2016 SHINGLES GAF (FL10124.1) EXTERIOR DOOR SECTIONAL EXTERIOR DOOR ASSEMBLY CLOPAY FL5678-R3 03/07/2015 ROOFING RIDGE VENT Florida Metal ACCESORIES Products Inc. FL2075-R7 03/09/2015 Panel Walls Soffits Mitten Inc. FL13275-R2 08/19/2015 ROOFING Modified Bitumen TAMKO Building FL735-R11 11/03/2016 Roof System Products, Inc. Structural Products Introduce os ResultofNew CAST-CRETE FL158-R9 05/21 /2017 Components P Technology USA, Inc. ROOFING Underloyments G.A.P. Roofing FL2894-R6 06/22/2015 OPTION DETAIL FOR NON SHUTTER PROOF WINDOWS NOT TO SCALE METAL 3/4" X 2" 2' IWALL ANCHORS EPDXYEDINTO MASONRY WALL g" W/1/2" X 2 2" N1 LAG SCREW W 2" 6„ DIA FLAT WACHER EA. CORNER & 1 EA ~ 1/2" ADX PLYWD 0 CENTER SPAN 6'0" SHIELD CUT TO FIT OR GREATER. LL ANCHORS EA OPENING. ATTACH ADDITIONAL PANEL &OXYEDINTO BILK. W/12" WIDE (6" BY SIDE) 1/2" PLYWOOD ATTACHED W/1" DRYWALL SCREW STAGGERED 0 10" O.C. IN BOTH SIDES o tp IF OPENING IS LONGER THAT 4' ALUM. FRAME WINDOW AS SPECIFIED 1/2" CDX PLYWOOD W/PRE - DRILLED >a I INSIDE MARBLE HOLES MATCHING CONCRETE SILL SILL W/ANCHORS TYP. EA I DOOR & WINDOW 6 OPEN. ALUM. FRAME * PLYWOOD PANELS WINDOW BEYONS (SEE DETAIL SHT EPDXY 3/4"x2" ANCHOR 8"x8"x16" CONC. SHALL BE MARKED FOR INSTALL INTO BILK C. BILK ACCORDING TO EACH SPECS.) CORNERS OPENING & ON SITE 0 TIME OF FINAL INSPECTION. \ •• wI Z .. •"•�J•, Z t .0 'l,y f)rOp�L - l��W - W o 0 s W � U W w b O�Ci H Iz� J cc cr_ Q LU CL aL�o 0 U Z aw�CU c) Z w z Uu _ Z Z W O r O_ I- ¢ o ,� c� o n_ cn z o ? WwOC ao r oC U Uj LUQ0 -5- Lu N LLI OCz J - CD zv0-iow wQ O Cr - W U� Z LU (.5 H 0 aa..w�0 0 20<LL C- LU 1- 2 z ¢ 0zZO cwi�av7 � O Z)m w Z o_W>-<n-OzW ¢ 0-1 J Lo W oCO q 0M Lq , E � O ° U. W \1/ C .� cm r �M @ �A Cn J -1 W _Ci C Z Co V q � � W � W Cn W Z V Z) a om O U O J 04 J J w LL QM 0 O >_J oLL Z a 000 z� Z V z� O LUM Q o= J O MN Q - W z o / 0. 06 O LL 0 J Z U Cn H E E T 02 N 0 TOTAL AREA 1 588 5f ;`�,� . • • Nip �., w =� IL �- co op • . WO -' •�oME g1- W PFo w o 0T-z�w J Q a a LLI CL LL = O CL 0 LIJ CD U z QwU ('') z ELECTRICAL RISER DIAGRAM N.T.S. o w o z p O z z_w r wwot- QC'J�_C'3 O a ,FI � oC WAS ER O ozw w N DRYER pW-��WEATHER HEAD AT 1 0'0" J z O TA wi 5 - MIN. ABOVE GRADE. Z LD ow w - - - - _ - - - - - - 21 RIGID CONDUIT 00 ui O O - ao�= cnwwU 41, 2" 2 HOLES 1111< 0 ~- a a)O 150 AMP STRAPS TYP. w w z 0 O =aQ� a w FUSED z ATTI DISCONNECT LL 0 In o Ozzc`n V O RAI TIGHT METER in M Fn a- 2 Z a lxw>—w—ozw O LIGHTING ARRESTOR #4 CU.WIRE #4 CU.WIRE O s) OWN.Mill h dk v A/C GALV. CONNECT TO r _----ROD---, NEAREST 51ONG WATER PIPE �J,4 N Lin.� TYP. c ca CM M n E O c0 0 0-0 ELECTRICAL NOTES L aw 4) � A- SMOKE DETECTORES SHALL BE INSTALLED IN ACCORDANCE W c 4> WITH NFPA 72, CHAPTEK2. THEY SHALL BE HARDWIRED INTO AN AC POWER SOURCE AND SHALL BE EQUIPPED WITH d MONITORED BATTERY BACK-UP. THEY SHALL BE WIRED IN SUCH CT, A MANNER THAT THE ACTIVATION OF ONE ALARM SHALL Cn C° ACTIVATE ALL THE ALARMS. U L J CoLL �..r B- AFCI PROTECTION IS REQUIRED FOR ALL CIRCUITS IN SLEEPING £ ❑O � ROOMS. W z Im L C- ELECTRICAL PLAN IS INTENDED FOR BID PURPOSES ONLY. ALL `" WORK SHALL BE DONE IN STRICT ACCORDANCE WITH THE ELECTRICAL PLAN NATIONAL ELECTRICAL CODE, LATEST EDITION, BY A LICENSED W U ELECTRICAL CONTRACTOR WHO SHALL BE RESPONSIBLE FOR SCALE 1/4" = 1' THE INSTALLATION AND SIZING OF ALL WIRING AND ACCESSORIES. ,Q! 9SCso b� ELECTRICAL NOTES: NEW WIRING PROVIDED NEW LIGHT FIXTURES PROVIDED THROUGHOUT THE PROJECT L j Z NEW ELECTRICAL SWITCHES (15 Amp. MIN.) PROVIDED THROUGHOUT Lj O THE PROJECT NEW ELECTRICAL OUTLETS (15 Amp. MIN.) PROVIDED THROUGHOUT U) THE PROJECT (GFCI AT WET LOCATIONS) D a NEW APPLIANCES PROVIDED THROUGHOUT THE PROJECT W ~ J uuC U w -� Lu M Z Qc� O O ZJ Z Y� a _ z TPU55 BEARING B'0' O = TOP LEVEL OF DOORS E WINDOWS G6 N a ❑❑ Z J a O F. F.ELEV. GO" F. F.ELEV. O'�8" Q W U � W FRONT ELEVATION S SCALE 1 /4" = I' H E E 03 T N O ELECTRICAL SCHEDULE SYMBOL DESCRIPTION SYMBOL DESCRI PiION INDICATES SWITCH LEG CIRCUITING CEILING MOUNTED INCANDESCENT LIGYIT o UNDER CABINET LIGm � 110 , CHANDELIER LIGHT FIXTURE DUPLEX RECEPi ACLE O O„R RECESSED MOJNIED INCAN OESC'_Nl uGHT / MOISIJRE RESISTANT DUPLEX RECEP7 ACLE MOUNTED ABOVE COUNTER Q 42' A.F.F. SWITCHED DUPLEX RECEPTACLE SURFACE MOJNIED INCANDESCENT LIGHT 220V RECEPTACLE y� {�} CEILING HUNG INCANDESCENT LIGHT (PENDANT) 220V RECEPTACLE MOUNTED ABOVE COUNTER Q 42' A.F.F. O� RECESSED DIRECTIONAL INCANDESCEN7 LIGriT x GROJND FA;1LT INTERRUPT RECEPTACLE WEATHERPROOF DUPLEX RECEPTACLE -- 4' STRIP FLOREBCENT ® SPECIAL PJRPOBE OU7LET 2' STRIP FLORESCENT FLOOR OUTLET W/ JVNCI ION BO% (=(yyi� 24' (4J BULB WALL MOUNItD LlGhll Sl RIP CEILING DULFT (rWyy.><yy.>rYy;1yn� 2LaLa(i[.lLafi 36' (6) BULB WALL MOUNTED UGHT STRIP WEATHER PROOF SOFFIT OUTLET � SECJRITY FLOOD LIGHT (MOTION SEN5.1 v WALL TELEPh10NE O EX HAJST FAN m FLOOR OUTLET FOR 7ELEPr10NE EXHA'JSl FAN W/ LIGHT 1 ELEVISION JACK SOFFIT FLOOD LIGHT DISCONNECT � INTERCOM f SINGLE POLE SWITCH e SECJRITv IOUCHPraJ $3 3-WAY SW1Cn � Pull -Chain fi.ture f< 4-WAY SWITCH 50 SMOKE DElEC70R $D DIMMER SWI7 CH 0 1'nERNO51A1 S DS DOOR SWITCH c5 CARBON MONOxIDE SENSOR 0 DOOR CHIME g Electnc Meter aPo PJSH BJITON FOR DOORBELL® 350 A Electric Panel a PUSH BUTTON FOR GARAGE DOOR OPENER ® SPEAKER PRE -WIRE JNDERGROJND CRCUITING (S) BLADE. (3) SPEED REVERBIBLE FAN W/LIGHT Meter (5) BLADE. (3) SPEED REVERSIBLE FAN O Gas Outlet PRE -WIRE f5) BLADE. (3) SPEED REVERSfBLE FAN TERMITE NOTES FLORIDA BUILDING CODE 6th EDITI❑N (2017) CHAPTER 3, SECTI❑N R318- PR❑TECTI❑N AGAINST TERMITE R318,1 TERMITE PROTECTION, SHALL BE PROVIDED BY REGISTERED TERMITICIDES, INCLUDING SOIL APPLIED PESTICIDES, BAITING SYSTEMS AND PESTICIDES APPLIED TO WOOD, OR OTHER APPROVED METHODS OF TERMITE PROTECTION LABELED FOR USE AS A PREVENTATIVE TREATMENT TO NEW CONSTRUCTION. See Section 202, Registered Termiticide, UPON COMPLETION OF THE APPLICATION OF THE TERMITE PROTECTIVE TREATMENT, A CERTIFICATE OF COMPLIANCE SHALL BE ISSUED TO THE BUILDING DEPARTMENT BY THE LICENSED PEST CONTROL COMPANY THAT CONTAINS THE FOLLOWING STATEMENT: 'THE BUILDING HAS RECEIVED A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN TERMITES, TREATMENT IS IN ACCORDANCE WITH RULES AND LAWS ESTABLISHED BY THE FL. DPT OF AGRICULTURE AND CONSUMER SERVICES', R31811IF SOIL TREATMENT USED FOR SUBTERRANEAN TERMITE PREVENTION THE INITIAL TREATMENT INSIDE THE FOUNDATION PERIMETER SHALL BE DONE AFTER ALL EXCAVATION, BACKFILLING AND COMPACTION IS COMPLETE. R31812IF SOIL AREA DISTURBED AFTER INITIAL CHEMICAL SOIL TREATMENT SHALL BE RETREATED WITH A CHEMICAL SOIL TREATMENT, INCLUDING SPACES BOXED OR FORMED, R31813SPACE IN CONCRETE FLOORS BOXED OUT OR FORMED FOR THE SUBSEQUENT - - INSTALLATION OF PLUMBING TRAPS, DRAINS OR ANY OTHER PURPOSE SHALL -BE CREATED- BY USING PLASTIC OR METAL PERMANENTLY PLACED FORMS OF SUFFICIENTE DEPTH TO ELIMINATE ANY PLANNED SOIL DISTURBANCE AFTER INITIAL CHEMICAL SOIL TREATMENT. R31814CHEMICALLY TREATED SOIL SHALL BE PROTECTED WITH A MINIMUM 6 MIL VAPOR RETARDER TO PROTECT AGAINST RAINFALL DILUTION, IF RAINFALL OCCURS BEFORE VAPOR RETARDER PLACEMENT, RETREATMENT IS REQUIRED. ANY WORK, INCLUDING PLACEMENT OF REINFORMENT STEEL, DONE AFTER CHEMICAL TREATMENT UNTIL THE CONCRETE FLOOR IS POURED, SHALL BE DONE IN SUCH MANNER AS TO AVOID PENETRATION OR DISTURBING TREATED SOIL, R31815CONCRETE OVERPOUR OR MORTAR ACCUMULATED ALONG THE EXTERIOR FOUNDATION PERIMETER SHALL BE REMOVED PRIOR TO EXTERIOR CHEMICAL TREATMENT, TO ENHANCE VERTICAL PENETRATION OF THE CHEMICALS, R318,1,%DIL TREATMENTS SHALL ALSO BE APPLIED UNDER ALL EXTERIOR CONCRETE OR GRADE WITHIN 1 FOOT OF THE PRIMARY STRUCTURE SIDEWALLS, ALSO, A VERTICAL CHEMICAL BARRIER SHALL BE APPLIED PROMPTLY AFTER CONSTRUCTION IS COMPLETED, INCLUDING LANSCAPING AND IRRIGATION/ SPRINKLER INSTALLATION, ANY SOIL DISTURBED AFTER THE CHEMICAL VERTICAL BARRIER IS APPLIED SHALL BE PROMPTLY RETREATED. R318,2 PENETRATION, PROTECTIVE SLEEVES AROUND METALLIC PIPING PENETRATING CONCRETE SLAB -ON -GRADE FLOORS SHALL NOT BE OF CELLULOSE -CONTAINING MATERIALS AND, IF SOIL TREATMENT IS USED FOR SUBTERRANEAN TERMITE PROTECTION, SHALL RECEIVE APPLICATION OF A TERMITICIDE IN ANNULAR SPACE BETWEEN SLEEVE AND PIPE. R318,3 CLEANING. CELLS AND CAVITIES IN MASONRY UNITS AND AIR GAPS BETWEEN BRICK, STONE OR MASONRY VENEERS AND THE STRUCTURE SHALL BE CLEANED OF ALL NONPRESERVATIVE TREATED OR NONNATURALLY DURABLE WOOD, OR OTHER CELLULOSE CONTAINING MATERIAL R AL PRIOR TO CONCRETE PLACEMENT, R318,4 CONCRETE BEARING LEDGE BRICK, STONE OR OTHER VENEER SHALL BE SUPPORTED BY A CONCRETE BEARING LEDGE AT LEAST EQUAL TO THE TOTAL THICKNESS OF THE BRICK, STONE OR OTHER VENEER WHICH IS POURED INTEGRALLY WITH THE CONCRETE FOUNDATION. NO SUPPLEMENTAL CONCRETE FOUNDATION POURS WHICH WILL CREATE A HIDDEN COLD JOINTS SHALL BE USED WITHOUT SUPPLEMENTAL TREATMENT IN THE FOUNDATION UNLESS THERE IS AN APPROVED PHYSICAL BARRIER. AN APPROVED PHYSICAL BARRIER SHALL ALSO BE INSTALLED FROM BELOW THE WALL SILL PLATE OR FIRST BLOCK COURSE HORIZONTALLY TO EMBED IN A MORTAR JOINT, IF MASONRY VENEER EXTENDS BELOW GRADE, A TERMITE PROTECTIVE TREATMENT MUST BE APPLIED TO THE CAVITY CREATED BETWEEN THE VENEER AND THE FOUNDATION, LIEU OF A PHYSICAL BARRIER, EXCEPTION: VENEER SUPPORTED BY A STRUCTURAL MEMBER SECURED TO THE FOUNDATION SIDEWALL IN ACCORDANCE WITH ACI 530/ASCE 5/ TMS 402, PROVIDED AT LEAST A 6 INCH (152 mm) CLEAR INSPECTION SPACE OF THE FOUNDATION SIDEWALL EXTERIOR EXIST BETWEEN THE VENEER AND THE TOP OF ANY SOIL, SOD, MULCH OR OTHER ORGANIC LANDSCAPING COMPONENT, DECK, APRON, PORCH, WALK OR ANY OTHER WORK IMMEDIATELY ADJACENT TO OR ADJOINING THE STRUCTURE, R318,5 FOAM PLASTIC PROTECTION. EXTRUDED AND EXPANDED POLYSTYRENE, POLYISOCYANURATE, AND OTHER FOAM PLASTICS SHALL NOT BE INSTALLED ON THE EXTERIOR FACE OR UNDER INTERIOR OR EXTERIOR FOUNDATION WALLS OR SLAB FOUNDATIONS LOCATED BELOW GRADE, THE CLEARENCE BETWEEN FOAM PLASTICS INSTALLED ABOVE GRADE AND EXPOSED EARTH SHALL BE AT LEAST 6 INCHES, EXCEPTIONS: 1, BUILDINGS WHERE THE STRUCTURAL MEMBERS OF WALLS, FLOOR, CEILINGS AND ROOFS ARE ENTIRELY OF NONCOMBUSTIBLE MATERIALS OR PRESSURE -PRESERVATIVE -TREATED WOOD, 2, WHEN IN ADDITION TO THE REQUIREMENTS OF SECTION R318,1, AN APPROVED METHOD OF PROTECTING THE FOAM PLASTIC AND STRUCTURED FROM SUBTERRANEAN TERMITE DAMAGE IS USED, 3, ON THE INTERIOR SIDE OF BASEMENT WALLS, R318,6 PROTECTION AGAINST DECAY AND TERMITES, CONDENSATE LINES AND ROOF DOWNSPOUTS SHALL DISCHARGE AT LEAST 1 FOOT AWAY FROM THE STRUCTURE SIDEWALL, WHETER BY UNDERGROUND PIPING, TAIL EXTENSION OR SPLASH BLOCKS. GUTTERS WITH DOWNSPOUTS ARE REQUIRED ON ALL BUILDING WITH EAVES OF LESS THAN 6 INCHES HORIZONTAL PROJECTION EXCEPT FOR GABLE END RAKES OR ON A FOOF ABOVE ANOTHER ROOF, ELECTRICAL NOTES 1. All work shall be in strict accordance with national electrical code all applicable local ordinances and in cooperation with the utility companies. 2. Coordinate all work with all trades. 3. Mount all outlets and receptacles plumb and flush with walls. 4. Receptacles shall be mounted 12" a.f.f unless shown otherwise. 5. Install electrical cable, wire and connectors as indicated in accordance with the manufacturer's written instruction, the applicable requirements of nec and the national electrical contractors association "standard of installation' and in accordance with recognized industry practices to ensure that production serve the intended functions. 6. All wire shall be std. #10 and #12 and shall be romex or nm cable Type "B" or approved equal. 7. Coordinate electrical requirements for A/C with A/C contractor. 8. R313.1 Smoke alarms. Smoke alarms shall be installed in the following locations: 1. In each sleeping room. 2. Outside each separate sleeping area in the immediate vicinity of the bedrooms. 3. On each additional story of the dwelling, including basements but not including crawl spaces and uninhabitable attics. In dwellings or dwelling units with split levels and without an intervening door between the adjacent levels, a smoke alarm installed on the upper level shall suffice for the adjacent lower level provided that the lower level is less than one full story below the upper level. When more than one smoke alarm is required to be installed within an individual dwelling unit the alarm devices shall be interconnected in such a manner that the actuation of one alarm will activate all of the alarms in the individual unit. The alarm shall be clearly audible in all bedrooms over background noise levels with all intervening doors closed. All smoke alarms shall be listed and installed in accordance with the provisions of this code and the household fire warning equipment provisions of NFPA 72. NOTES R309.1 Opening protection. Openings from a private garage directly into a room used for sleeping purposes shall not be permitted. Other openings between the garage and residence shall be equipped with solid wood doors not less than 1 3/8 inches (35 mm) in thickness, solid or honeycomb core steel doors not less than 1 3/8 inches (35 mm) thick, or 20-minute fire -rated doors. R309.1.1 Duct penetration. Ducts in the garage and ducts penetrating the walls or ceilings separating the dwelling from the garage shall be constructed of a minimum No, 26 gage (0.48 mm) sheet steel or other approved material and shall have no openings into the garage. R309.2 Separation required. The garage shall be separated from the residence and its attic area by not less than '/2-inch (12.7 mm) gypsum board applied to the garage side. Garages beneath habitable rooms shall be separated from all habitable rooms above by not less than 5/8-inch (15.9 mm) Type X gypsum board or equivalent. Where the separation is a floor -ceiling assembly, the structure supporting the separation shall also be protected by not less than 1/2-inch (12.7 mm) gypsum board or equivalent. R311.4.3 Landings at doors. There shall be a floor or landing on each side of each exterior door. Exception: Where a stairway of two or fewer risers is located on the exterior side of a door, other than the required exit door, a landing is not required for the exterior side of the door. The floor or landing at the exit door required by Section R311.4.1 shall not be more than 1.5 inches (38 mm) lower than the top of the threshold. The floor or landing at exterior doors other than the exit door required by Section R311.4.1 shall not be required to comply with this requirement but shall have a rise no greater than that permitted in Section R311.5.3. Exception: The landing at an exterior doorway shall not be more than 73/4 inches (196 mm) below the top of the threshold, provided the door, other than an exterior storm or screen door does not swing over the landing. The width of each landing shall not be less than the door served. Every landing shall have a minimum dimension of 36 inches (914 mm) measured in the direction of travel. R311.4.4 Type of lock or latch. All egress doors shall be readily openable from the side from which egress is to be made without the use of a key or special knowledge or effort. R311.5.2 Headroom. The minimum headroom in all parts of the stairway shall not be less than 6 feet 8 inches (2036 mm) measured vertically from the sloped plane adjoining the tread nosing or from the floor surface of the landing or platform. R311.5.3 Stair treads and risers. R311.5.3.1 Riser height. The maximum riser height shall be 73/4 inches (196 mm), The riser shall be measured vertically between leading edges of the adjacent treads. The greatest riser height within any flight of stairs shall not exceed the smallest by more than 3/8 inch (9.5 mm). R311.5.3.2 Tread depth. The minimum tread depth shall be 10 inches (254 mm). The tread depth shall be measured horizontally between the vertical planes of the foremost projection of adjacent treads and at a right angle to the tread's leading edge. The greatest tread depth within any flight of stairs shall not exceed the smallest by more than 3/8 inch (9.5 mm). Winder treads shall have a minimum tread depth of 10 inches (254 mm) measured as above at a point 12 inches (305) mm from the side where the treads are narrower. Winder treads shall have a minimum tread depth of 6 inches (152 mm) at any point. Within any flight of stairs, the greatest winder tread depth at the 12 inch (305 mm) walk line shall not exceed the smallest by more than 3/8 inch (9.5 mm). R311.5.3.3 Profile. The radius of curvature at the leading edge of the tread shall be no greater than 9/16 inch (14.3 mm). A nosing not less than 3/4 inch (19 mm) but not more than 11/4 inch (32 mm) shall be provided on stairways with solid risers. The greatest nosing projection shall not exceed the smallest nosing projection by more than 3/8 inch (9.5 mm) between two stories, including the nosing at the level of floors and landings. Beveling of nosing shall not exceed'/2 inch (12.7 mm). Risers shall be vertical or sloped from the underside of the leading edge of the tread above at an angle not more than 30 (0.51 rad) degrees from the vertical. Open risers are permitted, provided that the opening between treads does not permit the passage of a 4-inch diameter (102 mm) sphere. Exceptions: 1. A nosing is not required where the tread depth is a minimum of 11 inches (279 mm). 2. The opening between adjacent treads is not limited on stairs with a total rise of 30 inches (762 mm) or less. R312.1 Guards required. Porches, balconies or raised floor surfaces located more than 30 inches (762 mm) above the floor or grade below shall have guards not less than 36 inches (914 mm) in height. Open sides of stairs with a total rise of more than 30 inches (762 mm) above the floor or grade below shall have guards not less than 34 inches (864 mm) in height measured vertically from the nosing of the treads. Porches and decks which are enclosed with insect screening shall be provided with guards where the walking surface is located more than 30 inches (762 mm) above the floor or grade below. R314.1.2 Thermal barrier, Foam plastic, except where otherwise noted, shall be separated from the interior of a building by minimum 1/2-inch (12.7 mm) gypsum board or an approved finish material equivalent to a thermal barrier to limit the average temperature rise of the unexposed surface to no more than 250'F (121'C) after 15 minutes of fire exposure to the ASTM E 119 standard time temperature curve. The gypsum board shall be installed using a mechanical fastening system in accordance with Section R702.3.5. Reliance on adhesives to ensure that the gypsum board will remain in place when exposed to fire shall be prohibited. R401.3 Drainage. Surface drainage shall be diverted to a storm sewer conveyance or other approved point of collection so as to not create a hazard. Lots shall be graded so as to drain surface water away from foundation walls. The grade away from foundation walls shall fall a minimum of 6 inches (152 mm) within the first 10 feet (3048 mm). Exception: Where lot lines, walls, slopes or other physical barriers prohibit 6 inches (152 mm) of fall within 10 feet (3048 mm), drains or swales shall be provided to ensure drainage away from the structure. d. Three -eighths -inch -thick single -ply gypsum board shall not be used on a ceiling where a water -based textured finish is to be applied, or where it will be required to support insulation above a ceiling. On ceiling applications to receive a water -based texture material, either hand or spray applied, the gypsum board shall be applied perpendicular to framing. When applying a water -based texture material, the minimum gypsum board thickness shall be increased from 3/8 inch to 112 inch for 16-inch on center framing, and from 112 inch to 5/8 inch for 24-inch on center framing or 1/2-inch sag -resistant gypsum ceiling board shall be used. R703.7.5 Flashing. Flashing shall be located beneath the first course of masonry above finished ground level above the foundation wall or slab and at other points of support, including structural floors, shelf angles and lintels when masonry veneers are designed in accordance with Section R703.7. See Section R703.8 for additional requirements. WOOD NOTES 1. All framing members bearing interior & exterior shall be wood members with properties equal to or better than those given by the Southern Pine inspection bureau for surfaced dried Southern Pine no. 2 (minimum allowable bending stress -1290 psi for single members uses and 1400 psi for repetitive member uses, Modules of elasticity-1,600,000 psi). 2. All wood non -bearing exterior and interior walls to be #2 spruce pine fur (fb = 1,000 psi). 3. All wood girders shall have a min. of (4) - 2"x4" studs placed directly under the girder and double plate. 4. All lumber in contact with masonry or concrete shall be pressure treated. 5. All roof rafters and prefabricated wood trusses shall be securely fastened to their supporting wall or beams with hurricane clips or anchors as noted. it p 6. Prefabricated wood trusses shall be designed in accordance with the latest edition of the "national design specification for stress -grade lumber" and it's fasteners as recommended by the national forest products association. 7. Truss member and connections shall be proportioned (with a maximum allowable stress increase for load duration of 20% to withstand the load given in note. 8. Truss manufacturer shall submit shop drawings and design note with an engineers seal for approval. Design notes are to include the rated load capacity of the connectors used to secure the members, certification of the connector capacity's and manufacturers license to fabricate trusses utilizing the connectors system proposed. 9. Bridging for pre-engineered truss shall be as required by truss manufacturer in addition to member show on drawings. 10. Roof decks shall be 112" plywood or O.S.B. for fiberglass shingle roofs and 5/8" plywood for concrete or clay tile roofs. Use 8d nails with 4" spacing at all panel edges and 6" spacing intermediate supports. Provide plyclips at unsupported edges. 11. All wood frame details -shall be -in accordance with "NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION" latest addition, national forest products association, unless detailed otherwise on the structural drawings. 12. Roof live load =20 psf. Roof dead load =20 psf 13. Gable endwalls adjacent to cathedral ceilings are required to be continuous from floor to roof diaphragm. FBC 2004 2304.3.4.2. in r r other framing with common nails f I is hrams 14. Attach plywood sheathing to supporting trusses o g or gable d p only:(unless otherwise noted) 8d: a. 4" o.c. along edges of plywood panels. b. 6" o.c. along field of plywood panels. FOUNDATION NOTES Verify location of building at site using owners approved plot plan and adjust concrete footing, slab, landing, and steps, as grade requires. If conflicts between existing site conditions and approved plot plan arise contact T.G.C. 1. Prepare soil to receive 4" concrete slab min, w/ compressive strength of 3,000 p.s.i. @ 28 days w/ 6x6 10/10 w.w.m. or fiber mesh reinforced conc. barrier on clean, well compacted fill treated for termites. If fibermesh is used cut 1" joint every 15'-0" each way. 2. All footings to be 18" wide x 10" deep w/ (2) #5 rebar continuous (unless noted otherwise). 3. All thickened slabs (bell footing) to be 18" wide x 16" deep w/ (2) # 5 rebar continuos (place uplift strapping or anchors as may be required per code) unless noted otherwise. 4. All column pad to be 24" x 24" x 12" w/ #5 rebars @ 6" o.c. each way (unless noted otherwise). 5. All thickened edge slabs to be 12" x 12" w/ (1) #5 rebar (unless noted otherwise). 6, Thickened slab at floor elevation change is to be 8" deep x 16" wide w/ (2) #5 rebar continuous (unless noted otherwise). 7. Fill core with concrete and place (1) #5 rebar vertical from footing to tie -beam. 8. Pitch slab at grade at 1" in 1 U typical (in direction of arrow). unless noted otherwise 9. Recess floor slab 3/4" at all sliding glass doors and extend slab 1 112" past block face. unless noted otherwise 10. Extend slab edge at exterior doors 1 112" past block face. unless noted otherwise r r I min. u.n.o. w x #10 w.w.m. or fiber h. 11. Sunken shower to be 4 concrete recessed slab ( ) / 6 6 ( ber mesh). 12. Air conditioner compressor pad by mech. contractor to be placed 8" from wall, typical. 13. All stone or brick veneer footings to be 22" wide x 10" deep w/ (3) #5 rebars (min.) continuous (unless noted otherwise). 14. all footing for 2 story to be 24" wide x 12" deep w/ (3) #5 rebar continuous. (min.) 15. All thickened slab (bell footing) w/ two stories bearing to be 24" wide x 16" deep w/ (3) #5 rebars (place uplift strapping or anchors as may be required per code). 16. Thickened slab (bell footing) where at bearing wall occurs at change in floor elevation shall be a min. 16" deep x 16" wide continuous. 17. Assumed minimum existing soil bearing pressure = 2500 p.s.f. 18. Soil noted as compacted is 95% modified proctor, ASTM D1557. 6. The outer foundation bars shall be continuous around corners by bending the bar in accordance with 202.3.4 of the SSTD 10-93. In both cases the minimum bar lap shall be 40 bar diameter likewise, the bond beam reinforcement shall be continuous around all corners. 8. Provide 4" x 4" clean out for all concrete filled cells. at the base of wall. MASONRY/CONCRETE NOTES 2103.1 Concrete masonry units. Concrete masonry units shall conform to the following standards: ASTM C 55 for concrete brick; ASTM C 73 for calcium silicate face brick; ASTM C 90 for load -bearing concrete masonry units or ASTM C 744 for prefaced concrete and calcium silicate masonry units. CONCRETE NOTES: 1. All concrete shall have a minimum compressive strength of 3,000 psi at 28 days. 2. All reinforcing steel to be new domestic deformed billet steel conforming to astm a-615 grade 40 except that ties may be domestic steel conforming to astm A-615 grade 40. 3. Welded wire fabric shall conform to A-185. 4. Contractor shall verify locations of all openings, sleeves, anchor bolts, inserts, etc. as required by other trades before concrete is placed. No sleeves, openings pr inserts may be placed in beams or slabs unless approved by the architect and shown on shop drawings. 5. All reinforcing details to conform to "manual of standard practice for detailing reinforced concrete structures, ACI 315, unless detailed otherwise on structural drawings. 6. Provide spacers, chairs. bolts, etc. as required to assemble, place and support all reinforcing in place. 7. Provide corner bars for all footings. 8. All footing dowel bars shall have a standard 900 bend and shall be embedded 5" into -inch footings and a minimum of 6" into all others. Dowel bars lap vertical wall reinforcement a minimum of 40 bar diameters. 9, 2115.1 Gable endwalls. 2115.1.1 General. Gable endwalls shall be structurally continuous between points of lateral support, 2115.1.2 Cathedral endwalls. Gable endwalls adjacent to cathedral ceilings shall be structurally continuous from the uppermost floor to the ceiling diaphragm or to the roof diaphragm. 2. Steel reinforcement shall have a minimum yield strength of 40,000 psi in accordance with ASTM A-61.5. 3. Concrete Masonry Units, if any, shall be hollow core / load bearing in accordance to astm C90 or C145, 1,900 psi minimum. 4. Grout, if any, shall have 3/8" maximum aggregate, 8-11 inch slump 2,000 psi as per ASTM C476. 5. Mortar, if any, shall be Type M or S in conformance ASTM C270. PLUMBING NOTES 1. Provide plumbing fixtures, as selected by practical const. complete with all trim traps, stop valves, supplies and escutcheons. 2. All plumbing shall be is strict accordance with standard plumbing codes and local ordinances. 3. Soil waste and vent piping shall be schedule 40 pvc. 4. All water piping shall be type "I" with 95-5 soldered joints or c.p.v.c. 5. Copper piping underground and in contract with dissimilar metals shall be coated with tar enamel AWWA-C-203 or equal. 6. Provide individual water stops at all water closets, lavatories and kitchen sink installations. 7. Run all pipes concealed in wall, floors, above ceilings or below grade. 8. Verify all rough in requirements with the fixtures that are selected. 9. Coordinate all work with trades. 10. Provide full size piping from hot water p&t valve to exterior. 11. Water piping run through concrete or masonry shall be wrapped with 10-ml vinyl plumbing tape. 12. Hot water piping shall be insulated in accordance with county wide energy code. 13, gallon water heater (future). Unless noted otherwise. 14. Tank type water closet volume 1.5 gallons. 15. Water -flow rate. Shower heads 2.5 g. p. m. private facilities 2.2b gp m. 16. Plumbers must use a metal or plastic material to box out areas in concrete where drains are to be installed. 17, Thermal expansion protection is required when the water service is equipped with a back flow prevention device. 18. All back flow prevention devices are required to be tested and test results submitted to the building department before the certificate of occupancy is issued. GENERAL STRUCTURAL NOTES These plans meet the minimum requirements of the FLORIDA BUILDING CODE 6th EDITION (2017) . Concrete shall have a minimum compressive strength of 3,000 psi (unless noted otherwise) @ 28 days. 1. Pre -manufactured roof trusses to be designed in accordance with the latest tpi design requirements. The truss manufacturer is responsible to furnish all reaction loads for dead loads, live loads and wind loads. Manufacturer to submit truss layout and details signed by a florida registered engineer. 2. All exterior concrete block walls are designed as shear walls or shear wall segments with dur-a-wall reinforcement every other block as per the requirements of the National Concrete Masonry Institute. If dur-a-wall reinforcement is not used for the entire building, length of actual shear wall will be designated on the plans. The above can be omitted when a #5 down bar is installed @ each side of an opening. 3. All openings greater than 5 feet to have (1)45 bar on each side of opening and filled with grout. openings greater than 12 feet to have (2)-#5 bars on each side of opening. 4. Contractor to verify all dimensions and conditions in the field. 5, Any changes to sealed drawings must be approved by the professional engineer of record. 6. Structural design criteria: a. Basic Wind Speed =142 m.p.h. as per R301.2.1.5 Hurricane Map b. Applicable Internal Pressure Coefficient = Windward +0.18, Leeward -0.18 c. Components and cladding: refer to sheet A1.1 for design wind pressures in terms of psf (kn/m2) d. Building Catergory: II GENERAL NOTES 1. General contractor will verify all dimensions shown or implied before starting any work. 2. General contractor will comply with all building codes both state and local, and comply with all local authorities having jurisdiction. 3. It is the contractors sole responsibility to determine erection procedure and sequence to insure the safety of the building and component parts during erection this includes but is not limited to the addition whatever temporary bracing, guys, or tie downs that may be necessary, such material shall be removed and shall remain the property of the contractor after completion of the project. 4. All dimensions and elevations shown on the structural drawings shall be verified and shall conform to the architectural drawings. 5. Wall siding, including brick facing, painted block or stucco, must end 6 inches above the ground to allow for future termite inspections. the contractor can paint the bare band or apply a plaster -like finish less than 5/8" inch thick directly to the foundation wall. MECHANICAL NOTES 306.3.2 Air -handling units. Air -handling units shall be allowed in residential attics if the following conditions are met: 1. The service panel of the equipment is located within 6 feet (1829 mm) feet of an attic access. 2. A device is installed to alert the owner or shut the unit down when the condensation drain is not working properly. 3. The attic access opening is of sufficient size to replace the air handler, 4. A notice is posted on the electric service panel indicating to the homeowner that the air handler is located in the attic. Said notice shall be in all capitals, in 16-point type, with the title and first paragraph in bold: NOTICE TO HOMEOWNER A PART OF YOUR AIR-CONDITIONINGTEM THE AIR HANDLER I SYS S LOCATED IN THE ATTIC. FOR PROPER, EFFICIENT, AND ECONOMIC OPERATION OF THE AIR-CONDITIONING SYSTEM, YOU MUST ENSURE THAT REGULAR MAINTENANCE IS PERFORMED. YOUR AIR-CONDITIONING SYSTEM IS EQUIPPED WITH ONE OR BOTH OF THE FOLLOWING: 1) A DEVICE THAT WILL ALERT YOU WHEN THE CONDENSATION DRAIN IS NOT WORKING PROPERLY, OR 2) A DEVICE THAT WILL SHUT THE SYSTEM DOWN WHEN THE CONDENSATION DRAIN IS NOT WORKING. TO LIMIT POTENTIAL DAMAGE TO YOUR HOME, AND TO AVOID DISRUPTION OF SERVICE, IT IS RECOMMENDED THAT YOU ENSURE PROPER WORKING ORDER OF THESE DEVICES BEFORE EACH SEASON OF PEAK OPERATION. 5. Bathroom ventilation must me mechanically exhausted to building exterior, 6. Equipment disconnect must be within site. 7. All mechanical equipment including a/c condensers, pool pumps, pool filters and pool heaters shall be secured to resist location wind loads. GENERAL WINDOW & DOOR NOTES 1. Exterior front and back doors, windows, garage doors, cladding and components are submitted with the "Technical Manual" for installation and technical material specifications. 2. Nail and glue bucks, the wood between the door jamb and the wall. 3. The mullions - strips between a series of windows - must be certified to withstand the designed wind capacity. 4. Windows and glass doors must meet the impact standards. Window mfg, must have labels attached listing manufacturer, performance characteristics and certification that they have been tested. labels must stay on until the final inspection. 5. Any glazing within 36" horizontally and below 60" of the standing surface of a bathtub, shower, spa, etc., shall be safety glazed. FOUNDATION INSPECTION Notes: 1.) A foundation survey shall be performed and a copy of the survey shall be on site for the building inspector's use. or all property markers shall be exposed and a string stretched from marker to marker to verify required setbacks. FRAMING INSPECTION Notes: 1.) All Plumbing, Electrical, and Mechanical rough -ins smust be complete, inspected, and approved before requesting the framing inspection. w CC) w b oF_Z w= J d E EE aw3:IL �L0 0 U Z aw0 p w p Z z?w < E:0 wZEiK W W 0 w o� W<Crz 0- o ZcOo6yw Uppw U ~ Z w m U a w Z 0 =°QLL 2Z o°ZFn ° Cr n U)-:3g2 in Cr Q w a J �Z ry O L.L z (y) 0 0 0 T_ U Cn N 0 11111 0 z MW>-W-Ozcn CM 99 y1(1 O N O CV Ln E M "' O CD C Q� 0 r CO@ /�� roi LL E C� Z i S•�1 a v U ka CV WLO CM QM U_ WJ Z ZJ Y=(n CD a-O 0 MN Z S H E E T 04 N 0 FLAT CONCRETE TILE OVER SHEATHING W/ LONG DIMENSION 19 lb FELT PAPER OVER PERPENDICULAR TO FRAMING & 5/8" CDX PLYWOOD NAIILS 6 TO EDGESEAND 12ASATN W 8d OR INTERMEDIATE FRAMING. 3D FIBERGLASS SH► ]C ES OVER 15 LB. FELT P. ON 7 16 OSB SHEATHING OR 1/2' CDX PLYWOOD PITCH VARIES PER PLAN USP TA20 (SEE TRUSS DRAWING) HURRICANE ANCHOR 12" VARIE5I ELEVATION VARIES ALUM. FACIA -SOFFIT TRUSS z R H a > w w 5/8" STUCCO------- J w tiw TYPE "S" MORTAR w 0 8" C.M.U. TYPICAL z a w w R38 INSULATION 5/8" DRYWALL 1gg" XXX 4" PUTBNLAIILEDyy ¥5 R�q� CONT.B& FILLEDCWITFI ACRETE # 5 BAR CONT FROM FOOTER TO BOND BEAM W/ STD ® ea END SEE PLANS FOR LOCATION LAP SPLICE = 25" -8" X 8" X 16" CONC. BLOCK -1" PT FURRING STRIP ® 24" ox. -4.2_ ALFOIL INSULATION 1 /2" DRYWALL " x 4" PT NAILED IASE BOARD FLAT CONCRETE TILE OVER 19 Ib FELT PAPER OVER 5/8" CDX PLYWOOD OR WD, 3D FIBERGLASS SITYNG( ES OVER 15 LB. FELT P. ON ' 16 OSB SHEATHING OR 1/2 CDX PLYWOOD— USP TA20 HURRICANE ANCHOR ,---\ METAL MOISTURE BARRIER METAL DRIP EDGE ELEVATION VARIES VARIES 4"x4" INSPECTION POR °- AT EACH FILL CELL TYP. Z Ilk f in 0'-0" F.F. ELEV. a " a a FINNI5H GRADE ° STD.MHOOK° \ \�\ / /�\\1\ TI ICK .(3, 00 P.S.I. CONIC. SLAB W/ \\/� ` °\\�\\ W./ 1' LOVING FIBER ME H OR 6X6 1.4 x 1.J wwf ON 6 mm VAPOR BARRIER LAPPED 6 AND TAPED OVER CLEAN COMPACTED TERMITE NO VEGETAL MATERIAL ` TREATED FILL CLEAN POISONED 4 COMPACTED ' 2 #5 REDAR CONT. SOIL (COMPACTED TO 95%) 12' 123" MIN. COVER TYPICAL WALL SECTION O (TI i RU FILLED CELL) SCALE 3/4"= 1'-0" 20- MIN_ LAP #3 OR #4 REINFORCING BAR #3 & #4 LAP SPLICE 36" MIN_ LAP #6 REINFORCING BAR #6 LAP SPLICE 25- MIN_ LAP #5 REINFORCING BAR #5 LAP SPLICE #5 REINFORCING BAR R 1 7/8" 10" #5 STD. 90 HOOK OVERLAP REQU I REM ENT5 8 NOT TO SCALE 5/8" STUCCO SHEATHING W/ LONG DIMENSION PERPENDICULAR TO FRAMING END JOISTS STAGGERED. FASTEN W 8d NAILS G" @ EDGES AND 12" AT INTERMEDIATE FRAMING. PITCH VARIES PER PLAN (SEE TRU55 DRAWING) j 12" \\ VARIES 1 PRE—ENGINEF•RING WD. TRUSS O 24 O.C. R38 INSULATION DRYWALL 11g" XXX 4" PUTBNLApILEDyy #5 R�gq CONT.B& FILLEDC WITH/1CONCRETER I" X2" PT FURRING I" X 4" PT NAILED MARBLE STOOL w 1" X 2" PT FURRING x CONIC. SILL 4.2 ALFOIL INSULATION W 1 2" DRYWALL CQ 1" X 4" PT BASE NAILED BASE BOARD 4"x4" INSPECTION PORT___J AT EACH FILL CELL TYP. 0'-0" F.F. ELEV. ° A A G e a 'v FINNISH GRADE ° STUD LATERAL SUPPORTING ROOF AND SUPPORTING 1 FLOOR, SUPPORTING 1 FLOOR, SIZE UNSUPPORTED CEILING ONLY ROOF AND CEILING ROOF AND CEILING STUD HEIGHT (FT.) (IN) (IN) (IN) 2x4 10 24 16 — 3x4 10 24 24 16 2x5 10 24 24 — 2x6 10 24 24 16 MAXIMUM STUD SPACING 9 NOT TO SCALE SPECIE GRADE GENERAL LOCATION SOUTHERN YELLOW PINE 2 STRUCTURAL COMPONENTS (TRUSSES OR CONVENTIONAL FRAMMING) SOUTHERN YELLOW PINE (TREATED) 2 PARTITION AND FURRING (IN CONTACT WITH CONCRETE) SPRUCE 2 PARTITION AND DECORATIVE COMPONENTS RG02. I Identification. Load -bearing dlmenslon lumber for studs, plates and headers shall be Identified by a grade mark of a lumber grading or inspection agency that has been approved by an accreditation body that complies with DOC PS 20. In lieu of a grade mark, a certification of Inspection issued by a lumber grading or inspection agency meeting the requirements of this section shall be accepted. RG02. 1 .1 End jointed lumber. Approved end jointed lumber identified by a grade mark conforming to Section RG02. 1 may be used interchangeably with solid -sawn members of the same species and grade. RG02. 1.2 Structural glued laminated timbers. Glued laminated timbers shall be manufactured and identified as required in AITC A 190. 1 and A5TM D 3737. RG02.2 Grade. Studs shall be a minimum No. 3, standard or stud grade lumber. Exception: Bearing studs not supporting floors and nonbearing studs may be utility grade lumber, provided the studs are spaced in accordance with Table KG02.3(5) . 1— #5 BAR CONT. 3" MIN COVER 0 3 THICKENED EDGE N .T.5CALE MINIMUM VVALL ANl) HEADFR STUD REQUIREMENTS 2 15E18 rc Ira E �f - :der - F2] uIIJpl-, II7J �l( or , r'nGl I `_tuds IeiGlll Sp'l 1q, ()t_ Fi h Find cT 1-1eader a 2 _ i 4" THICK ( 000 P.S.I.) CONIC. SLAB W/ T III equl i i= t 1 W/ 1' LONG FIBER MESH OR 6X6 1.4 K 1.4 WWF ON 6 VAPOR BARRIER LAPPED 6 AND TAPED OVER CLEAN COMPACTED TERMITE NO VEGETAL MATERIAL TREATED FILL CLEAN POISONED & COMPACTED SOIL (COMPACTED TO 95%) 12• 12• 2 #5 REBAR CONT. 3" MIN. COVER TYPICAL WALL SECTION. O (TM RU WINDOW) SCALE 3/4"= 1'-0" HURRICANE CLIPS OR TRUSS ANCHORS - SEE ROOF TRUSS LAYOUT FOR SPECIFICATIONS STRAP TOP PLATE & HEADER TOGETHER W/2 RT18 MIN. U.N. 2x12 /�2 SYP W/1 /2" PLYWD OR 7 16" O.S.B. FLITCH 2x CRIPPLES UNDER HEADER AT END OF HEADER HEADER DETAIL 1- #5 BAR #5 BAR w/ STD 90-DEG HOOK EMBEDDED 6" INTO TOP LINTEL BLOCK, LAP SPLICE 25" #5 BAR VERTICAL REINF. IN GROUTED CELL #5 FOOTING DOWEL w/ STD 90-DEG HOOK EMBEDDED 6" MIN IN FOOTING (5" MIN IN 8" THK FOOTING) AND WITH 25" LAP LENGTH ABOVE SLAB BOND BEAM MIN COVER CLEANOUT REQUIRED FOOTING 6 VERTICAL REINFORCEMENT (AT EACH FILLED CELL) SCALE 3/4"= 1'-0" WOOD HEADER SCHEDULE FLOOR & ROOF SPAN = 36'-0" MAX WIND SPEED = 145 MPH LOCATION SIZE SPAN JACK STUDS UPLIFT ANCHORAGE EA. END (LBS)1 EXTERIOR BEARING WALLS SUPPORTING ROOF & CEILING ONLY 2 - 2x4 2'-10" 1 666 2 - 2x6 4'-2" 1 979 2 - 2x8 5'-4" 2 1253 2 - 2x10 6'-6" 2 1528 2 - 2x12 7'-6" 2 1763 3 - 2x8 6'-8" 1 1567 3 - 2x10 8'-2" 2 1919 3 - 2x12 9'-5" 2 2213 4 - 2x8 7'-6" 1 1763 4 - 2x10 9'-5" 2 2213 4 - 2x12 10'-11 " 2 2565 INTERIOR BEARING WALLS SUPPORTING ONE FLOOR ONLY 2 - 2x4 2'-5" 1 0 2 - 2x6 3'-6" 1 0 2 - 2x8 4'-5" 2 0 2 - 2x10 5'-5" 2 0 2 - 2x12 6'-3" 2 0 3 - 2x8 5'-7" 2 0 3 - 2x10 6'-9" 2 0 3 - 2x12 7'-10" 2 0 4 - 2x8 6'-9" 1 0 4 - 2x10 7'-10" 2 0 4 - 2x12 9'-1" 2 0 TIE DOWN SEE PLAN 8" C.M.U. SIMPSON SP2, EA. STUD TO - TOP PLATE (ONLY IF WALL IS SUPPORTING ROOF) IF ADJACENT TO MASONRI -- ATTACH END STUDS 1 WALL w/ 1 /4" x 4" TAPC INTO MASONRY 0 16" O.C. SIMPSON H2.5, EA. TRUSS TO TOP PLATE _—WOOD ROOF TRUSSES IMPSON SP4, JACK STUD TO TOP PLATE EA. END (ONLY IF WALL IS SUPPORTING ROOF) DOUBLE 2x4 TOP PLATE #2 SYP TUDS #2 0 16" O.0 ALUMINUM THRESHOLD SET IN FULL BED OF CAULK 4 WHEN BY—PASS ENTRY DOOR N .T.5CALE E STUD AT EACH END LL (#2 SYP) CEILING: 5/8" DR) 1/2" CEILING BOAF SP4, JACK STUD TO TOP A. END (ONLY IF WALL IS PING ROOF) BOTTOM PLATE (ONLY IF WALL IS SUPPORTING ROOF) FRAME WALL TO BLOCK WALL CONNECTION DETAIL 1'x4" P.T. WOOD BUCK W/ I*< TAPCON SCREWS 0 4 O.C. FROM THE ENDS & 15" O.C. MAX. ELSEWHERE EMBEDDED IN CAULKING FOR OPENING BETWEEN 3' & 8' J IMPACT RESISTING PROVIDE 1 #5 IN CONC. FILLED CELLS GLAZING OR STORM PROVIDE DOWELS AT FOOTING SHUTTER REQUIRED. OR THICKENED SLAB & EXTEND TOP OF BAR 8' INTO CONC. TIE BEAM ABOVE WI1H 6' HOOK. TIE DOWN DETAIL C (TD) SCALE 2" = 1'-0" EMBE SCALE 3/4"= I'-0" I ILI 0 4" LONG #5 REBAR GLUE `,N/EPDXY EVERY 3 BLOCKS �� PROPOSED FOOTER I EXISTING HOUSE ADDITION NEW TO EXISTING CONNECTION DETAIL N.T. s 1/2" DRYWAL )RYWALL TYP. IS 0 24" O/C 4TE TYPICAL NON -LOAD C]C A F-]IA 1/-% IA ITCF')In IA /A I I (THRU WINDOW) N.T.5CALE #5 BARS CONT. E.CL z STD 90-DEG HOOK TO VERTICAL REINFORCEMENT LO IT, BENT CORNER BAR 25 MIN LAP BOND BEAM CORNER REINFORCEMENT SCALE 3/4"= 1'-0" TE 5/8) STUCCO FINISH CONCRETE BLOCK WALL OR CONCRETE CONT. SEALANT. WOOD MOLD. 2" X 6" WOOD BUCKING AS REQ. ON ALL EXT. DOORS AND WINDOWS 1/4" X 5" LONG TAP CONS. 12" O.C. FOR JAMB AND HEAD NOA # 02-0503-07 WOOD SHIM WOOD FRAME. WOOD TRIM CONT. SEALANT WOOD FURRING. CORNER BEAD. 5/8" GYPSUM BOARD OVER 1" FURRING CHANNEL WITH INSULATION ® ALL EXTERIOR WALL WOOD BUCKS DETAIL (EXTERIOR DOOR) N.T.S. I III I rr,' % /,,II ` ) C) r O w U - o LLJ op N w0 LU w �rr/rlllll� w W'/^J 00 w c OI- IzI- 2 a zIaEFC Q W d aLLZ)o O U Z UQ w lS CU 0 w 0z M O Z O — z Z W Q 0 [L r o n. w w Z 5 c U C'3p�w WW Q =Z CV U) LU 0 Z U U` yW0W QOU= LU ZW m - wZ0 U a) gcc 0 =0}ILi CL LLI-2z 0 Q 0 0zg55 LU (n=,a2 O �m CC w z U,I U)-Oz0 (_ S E T 0 • h v CM in a, W c o . rNi E Pon' O " v- CO00 O v a i W O O «O 4) •� 3ci) r @) V , Ili J co LL Wz~ _ E ci A ^^�, 0 w U W W Cn 1..1.E U J CV LU > L0 CO t' J O >_J o'_ W (D ZJ zJ cn UJ Q O� = J O Mw W Q N Z 0. O 1 U 05 E S SCALE 1 ":30' North per Plat L e g d.- AIC - AIR CONDITIONER WPP - WOOD POWER POLE CALC - CALCULATED C&M - CALCULATED & MEASURED Z - CENTRAL ANGLE CBW - CONCRETE BLOCK WALL CLE - CHAIN LINK FENCE CENTERLINE C. M. - CONCRETE MONUMENT CMP - CORRUGATED METAL PIPE CONC - CONCRETE COVD COVERED CID - CONCRETE PAD CW - CONCRETE WALKWAY D&M - DEED/DESC & MEASURED DE - DRAINAGE EASEMENT DESC - DESCRIPTION DW - DRIVEWAY EB - ELECTRICAL BOX ESMT EASEMENT E/P - EDGE OF PAVEMENT FIRM - FLOOD INSURANCE RATE MAP F. F. E. - FINISHED FLOOR ELEVATION T. B. M. TEMPORARY BENCHMARK END - FOUND I. P. - IRON PIPE I. R. - IRON ROD L - ARC LENGTH - LIGHT POLE LSA - LANDSCAPED AREA MEAS MEASURED ID. - IDENTIFICATION I. R. C. - IRON ROD AND CAP N&D - NAIL & DISK NGVD - NATIONAL GEODETIC "-FN D %2" VERTICAL DATUM I. P. NTS - NOT To SCALE U OHE - OVERHEAD ELECTRIC . N 0 I D . OL ON LINE O.R.B. - OFFICIAL RECORDS BOOK Oo PC POINT OF CURVATURE O PG PAGE PI POINT OF INTERSECTION FIND z 0 %2" I.P. NO ID.Ln .� T.B.M. # 2 ELEV.=91.62' 1.00'(OF 2.26'(OF ) 5' WD.FC. 4.42' (OFF PARCEL ID: 12-26-21-0000-05200-0040 N89 056'531 169.43)(M) N89 056'53'E 169.48'(P) 6' C L. F. �10, U.E. 00 N LOT-7 Ln 70 5' C. L. F. ^� �' C, � LOT-6 �, Cod , IVC CN 19 1_3o CURVE 'C-2' o o RF S Tangent: 10.87 (C) o oo 0 10.9 8' Chord: 21.3 5' (P) z z F 96p Course: S 74°26' 10" W(P) �o �9 92 r Arc Length: 21.48' ( P ) 26 7O �0 1 00 Radius: 55.90'(P) Lj_j C� Delta: 22°0017" (C) � 7.69 (OF) v w oCP N89 °57'43"E 64.27 M) 9.61'(OFF ( / o N89 °59'30"E 64.41 ' P 5 C.L. F () C2 P. C. ISE 0 SET 1 /2"I.R. ° LB # 7615 D � a EDGE OF P A V EMEN T P&M PLAT & MEASURED Z�t - P.O.B. - POINT OF BEGINNING j� KENNEDY AVE P.O.C. POINT OF COMMENCEMENT O O WPP - WOOD POWER POLE 50' RAW (PER PLAT PT - POINT OF TANGENCY �- PVC - PLASTIC PIPE o o ASPHALT PAVEMENT R CURVE RADIUS o R/W OR R.O.W. - RIGHT OF WAY Z TV - CABLE TV RISER TYP - TYPICAL U.E. - UTILITY EASEMENT UNTO - UNDERGROUND TELEPHONE W WATER LINE WATER METER ►f - WATER VALVE # - NUMBER R - EASEMENT NUMBER P PLAT D - DEED F - FIELD C&G - CURB AND GUTTER NAVD - NORTH AMERICAN VERTICAL DATUM M - MEASURE N89059'30"E 89.41 '(C) N89 °58'00 "E 89.6 7'(M) LOT-58 SURVEY NOTES: - THERE ARE FENCES ALONG THE NORTHERLY AND SOUTHEASTERLY BOUNDARY LINES. - THERE ARE NO OTHER SIGNIFICANT OBSERVATIONS. 7 p vq0 \0� SITE PLAN FOR: CALIFORNIA LAW GROUP LLC TRUSTEE I,--, 00 6' C.L.F. RISE . 6), , \ rO �v LOT-8 X D� 'C- CURVE l' Tangent: 25.09' (C) Tangent:25.09' (M) Chord: 45.78' (P) WATER METER o SET 1 /2"I.R. Chord: 45.78' (M) RISE LB # 7615 Course: S 70°23'04" E(P) WPP Course: S 70°23'07" E(M) \ rO �,J Arc Length: 47.16 (P) Arc Length: 47.16'(M) Radius: 55.90'(P) Radius: 5 5.90' (M) Delta: 48°20'33" (C) I Delta: 48 20 33 (M) FIN D P. C. P. �--- 4 x 4 C. M. 11__1 E--- LB #827 U-J T.B.M.# 1 R/ 1: w w ELEV.=88.13' V J cl, (V W Qr4 �z - 5' C. L. F. RESIDENCE REMODELING 39601 KENNEDY AVE ZEPHYRHILLS, FL 33542 N FND P.R.M. ,�= °�w� 4x4 C.M. _2, e 1_13#827 Q W O �- U� _ 0 Uz < W ; z cd oWz OZ _0 0 � Q C7 go; III ww�� O 0 CL ID o U) �J occ - � C7 ZUww - - U o p w U W U Legal Description: CID W g W z :OE :-7 0 =�}LL Lot 7, LINCOLN HEIGHTS SUBDIVISION, according to the LL o z Z - map or Plat thereof as recorded in Plat Book 13, Pages U M a. 2 o 113-114, Public Records of Pasco County, Florida. _ Cr < a_ z �w>-U)-0ZU) r� 19"O Surveyor's Notes: W 1. AMLe al Description provided by others �o 2. The lands shown hereon were not abstracted for easements or 0 =� � �-•+ other recorded encumbrances not shown on the Plat. a" c 4> 3. Underground portions of footings, foundations or other improvements w 0 were not located. �i� •r-+ 4. Wall ties are to the face of the wall and are not to be used to ("co @ � reconstruct boundary lines. U R U.s�4.0 w 5. Only visible encroachments located. � 2 6. No identification found on property corners unless otherwise shown. w z~ � 7. Dimensions shown are Plat and Measured unless otherwise shown. A T 8. Fence ownership not determined. 9. This survey depicted here forms a closed geometric figure. w V 10. No underground improvements or visible installations have been located other than shown. bJ 11. This survey is prepared for the exclusive use and benefit of the parties listed hereon liability to third parties may not be transferred or assigned. 12. This drawing may not be scaled due to electronic transfer. W 13. This survey does not reflect or determine ownership. Lij 14. Fence corners and building corners are witness monuments to � obstructed corners, dimensions are as shown. U) 15. Subject to any dedication, limitations, restrictions, reservations, D and/or easement of record no examination of Title made by 0_00 Surveyor, I1NN__ 16, This Survey is not an ALTA/ACSM Land Title Survey, U 17. This Survey was prepared without the benefit of a commitment for Title Insurance. LU 18. The flood data provided is for informational purposes only. The D CO QM Surveyor mares no guarantees as to the accuracy of the >-U_ Information provided. The local E.E.M.A. Agency should be contacted O 0 - for verification. ZJ Z 19. Elevations shown hereron are based on the Benchmark COLLINS, with UjE Elevation 82.18 (NA&diB ied t0/for the exclusive use of.- 3: 2 California Law Group LLC Q C) a J cfl W Q `Y' N Cn R/ Q BCBIS of Beango Olf 1.Bearing shown hereon are based on NORTH THIS SURVEY MEETS THE "STANDARDS DE O property line Of Lot 7, being N8'56 53 E, per Plat. PRACTICE" AS REQUIRED BY CHAPTER 5J- 1 7, Lj_ BOARD OF PROFESSIONAL SURVEYORS AND MAPPERS, PURSUANT TO SECTION 472.027 OF THE FLORIDA STATUTB. U Blood Insurance Rate Map Community Dumber: 120235 Panel: 0456 Suffix n' Flood Insurance Rate Map Dated September 26, 2017 Flood Zone: X " H E T N 0 SITE Map ID: 12 7 01 CO456F