Loading...
HomeMy WebLinkAbout4330 20th St (45)EXISTING - EXIT DOOR A-C UNIT. SEE MECN PLANS 4'-0"± I EXIST C PARTS REC. A20 - ff� O_ ■ ' CONEW 3-00-0 MTL ■ ■' DOOR WITH 1/2 LITE W o 6" BOLLARDS ' TYP. 0 ■ ■ NEW 5'xq'-4" 0 HIGH COIL DOOR ■ 0 ----------------------- 3'-0" ■ 0 L ■ I II SOT AN REMOVE EXISTING EXIT CHAIN -LINK FENCE. CONSTRUCT NEW p r CA CMU WALL 1 /71xl� 31'-3"+ I ■ ■ REVISIONS: 225'-0"± j, DATE:9-25-08 - PER BLDG DEPT II ATE IL A I 200 C_l 42" GUARD c - I 1 RAIL � iILL ■ ■ Ott ASSUMED ELEVATION - 100'-0" ■ ■ c r O o �n -- - - ----- -------- -U3 U EXISTING TO REMAIN Ali n LLI I ■ p -CL� LL ■ O N I ■ ■ .� U O :3 O jj UP I, 1 I 0 o� o NEW 3-6 x 7-0 MTL LVV DOOR WITH I/2 LITE AND PRECAST GONG, LINTEL ABOVE (DESIGNATED EXIT) REMOVE EXISTING CHAIN LINK FENCE T14I5 AREA +1 I y I o —J ' IAPPROX LOCATION OF EXISTING ELECTRICAL SYSTEMS i � I I I i I i I t I i ■ �� L=- � I I I � I I I I I I ■ it I 40.� 1 �',AC�D'L ■_ EXISTING � I I I � I AB V � I I ■�' lu,' OFFICE SL LU III � l I I I I I i I I i I ■,�, I I I I I I I I I �■ 2 ■ ■ ■ ■■■■ter r■rT ■ ■ 200 > 1■ I I I I I I I I I I I ■ -� - li I I 22-Kl BAR JOISTS @ 3'-0" O.C. W/ (2) ROWS OF BRIDGING 100 PSF MAX LOAD ba' -oll FIELD VERIFY T14I5 DIMENSION W/ OWNER REP ON51TE FOR NEW DOOR LOCATION NOTCH IN DIAMOND PLATE FOR PUMP DIAMOND DISCHARGE LINE PLATE TOP 75-0" OR NEW MASONRY WALL BEYOND I"xl" ANGLE SUPPORT FOR DIAMOND TOP PLATE CONTRACTOR OPTION: 1 1 GONG. BOTT. 2'-0" SQUARE x 2'-0" 21-0" AND SIDES DEEP 10ga 304 S.S. BOX. SQUARE SECTION A -A Esc NLARGED PLAN DIAMOND PLATE TOP SEE MECHANICAL PLAN FOR DECK-TITE DETAIL 225' -0"± J^ � N PUMP 6" THICK 75'-0" OR MINIMUM TO HIDE 11 'I MINIMUM TO HIDE (3) CONDENSERS NEW 8x8 COIL DOOR. DOOR CONTROL ON BOTH LEVELS 6' LETTERING THAT READS "CHEMICAL - STORAGE ROOM" 1 'k 0 - I EXISTING SLAB EXISTING STEEL FRAME 5' -0" 1 FIRE EXTINGUISHER J Q �� o O ■ ■ FLOOR PLAN SCALE: 1/8" = V-0" A-C UNIT. SEE MECN PLANS (TYP) OL EXISTING ELEVATION - 112'-7-5/8"± If EXISTING STORAGE TO REMAIN REMOVE AND STORE (FOR OWNER) EXISTING HANDRAIL AT MEZZ MEZZ. ABOVE SCALE: 1/8" = V-0" DIAMOND 31_011 PLATE TOP HAND `SINK Q EMERGENCY cn SHOWER z -4'-011 )SLAB EXISTING ACCOMODATE = POURED FULL CELL NEW 3-0 NEW FIXTURES x 7-0 #5 VERTICAL REINFOREMENT IN POURED FULL CELL TIED INTO FOOTER AND TIE BEAM AT TOP OF WALL WITH 90° STANDARD HOOK AT V-0" O.C. MAXIMUM SPACING FOR ALL EXTERIOR WALLS AT BOTH SIDES OF OPENINGS, AND 6" BOLLARDS HE AS SHOWN ON TFOUNDATION PLAN (TYP.) _0_ �I I I I = I ogX I C) EXISTING W 0 I I SLAB i I O I ■ ■ I ■ P' A T 3-Ox7-0 MTL .L--L- DOOR WITH HALF LITE I m CN � N I 00 (O o � � 00 00 OX r rY 00 0 v A Q°0 Q OE CD ■■�■■ 200 Lv �m n -0 (U m�CNC� i NC) o II Z ■ ^, 0 O ■ � L J H 0 ■ _ z o ■ ■ I ■ 7 ■ L IN I Q ■ ■ 4211 I GUARD � O RAIL ■ ■ ■ ■ FIELD VERIFY THIS DIMENSION W/ STAIR LENGTH AND DOOR ABV. MIN 48". AND TO ALSO AVOID THE ELEC BOXES AND CONDUITS BELOW. FIELD VERIFY ALL STAIR DIMENSIONS EACH END ON WALL 411_811 �� MOUNTED MTL RACKS FLOOR PLAN "' N�� ROOF PLAN CHEMICAL STORAGE ROOM OVERALL PLAN SCALE: 1/32" = V-0" SCALE: 3/16" = V-0" SCALE: N.T.S. GENERAL PLANS REVIEW COORDINATION NOTES SYMBOL LEGEND WALL LEGEND Building D • CODE g OEW MIECIM THIS JOB CONSISTS OF AN INTERIOR CHEMICAL STORAGE ROOM ADDITION AND MEZZANINE REMODEL governing bldg code 2004 Florida Building Code IT 15 INTENT THAT ALL WORK SHALL CONFORM TO THE ADOPTED CODES, STANDARDS INFORMATION THAT MIGHT BE CONTAINED WITHIN THESE DRAWINGS PERTAINING # ALL REQUIRED EXITS; WAY OF APPROACH THERETO; AND WAY OF TRAVEL (EXISTING PARTS ROOM STORAGE AREAS WILL REMAIN SAME AFTER ENCLOSER) ROOM NAME ! RULES OF THE ADMINISTRATIVE AUTHORITY HAVING JURISDICTION TO APE PROTECTION, SPRINKLES AND/OR ALARM DEVICES (IF APPLICABLE) building use/occupancy BLDG- F-2 *HANDICAPPED A fil': ARE SOLELY FOR TINE PURPOSE OF COORDINATION OF THE ARCHITECT'S/ FROM THE EXIT INTO THE STREET SHALL BE CONTINUOUSLY MAINTAINED FLOOR COVERING, FURNISHINGS, PAINT COLORS, II � PROJECT S-2 TRIM MATERIALS AND OTHER ITEMS NOT SPECIFIED 8 CMU WALL W/ 5 REBAR @ 8 O.C. AND FREE FROM ALL OBSTRUCTIONS AND IMPEDIMENTS FOR UNOBSTRUCTED 205 ROOM NUMBER �-� IT 15 THE INTENT THAT ALL WORK SHALL CONFORM WITH THE LOCAL AND STATE DESIGNERS WORK. THESE ARE NOT ENGINEERING DRAWINGS, EGRESS IN THE CASE OF FIRE OR OTHER EMERGENCY. IN THESE SECTIONS ARE TO BE AS SELECTED direction of view FOAM FILLED CELLS construction type II 'two' B unprotected ACCESSIBILITY REQUIREMENTS HAVING JURISDICTION SPECIFICATIONS AND OTHER DOCUMENTS THAT ARE REQUIRED SHALL BE PROVIDED BY OWNER IN CONFORMANCE TO ALL FLOOR 5 C 1 A BY THE INSTALLING CONTRACTOR, (SIGNED AND SEALED BY A STATE REGISTERED #ALL WORK SHALL CONFORM WITH DRAWINGS AND SPECIFICATIONS APPLICABLE CODES. detail # wind speed 110 mph • AMEMANB WITH DIBARLITE3 ACT ° ENGINEER). SUBMIT COPIES TO OWNER FOR REVIEW AND ACCEPTANCE, (IN ADDITION BASE CEILING I N A I H ALL APPLICABLE GOVERNING MUNICIPAL AND stories N ACCOR D CE W 7 L PPL LE G VE G CONTRACTOR 70 VERIFY ALL EXISTING CONDITIONS AND 1 WHILE THE DESIGNER HAS TAKEN MUCH CARE AND IMPOSED PROCEDURAL TO THE LOCAL BUILDING AND FIRE DEPARTMENT REVIEW OFFICE. WALLS , s STANDARDS WITH THE INTENT OF ADA COMPLIANCE (LATEST EDITION) REGULATORY AGENCIES, CODES AND REQUIREMENTS. IT SHALL BE DIMENSIONS PRIOR TO STARTING CONSTRUCTION. SECTION 3-5/8" 20GA MTL STUD WALL @ 16" O.C. W/ sprinkler stem modify UNDERSTOOD THAT ALL INTENDED WORK I5 SUBJECT TO REVIEW AND P Y Y per NFPA 13 THESE DRAWINGS ARE PROVIDED WITH NO WARRANTY EITHER EXPRESSED OR • EXIBTNCi CONDIT10W8 ALL CONSTRUCTION SHALL CONFORM TO THE MARK I/2" GWB EACH SIDE AND R-II BATT INSULATION IMPLIED OF SAID COMPLIANCE AND THE ENGINEER/DESIGNER, STAFF AND/OR THE CONTRACTOR SHALL VERIFY EXISTING CONDITIONS AND FIELD COORDINATE INTERPRETATION BY THE ADMINISTRATIVE AUTHORITY HAVING JURISDICTION, AND IN NO CASE SHALL WORK BE PERFORMED WITHOUT THE REVIEW (OR EQUAL) ECHANICAL, exposure B RETAINED CONSULTANTS A55UME NO LEGAL RESPONSIBILITY FOR THE ACCURANCY CORRECTIVE ACTION AS REQUIRED. THE GENERAL CONTRACTOR SHALL NOTIFY WINDOW sheet loc tion importance factor 1 OF THE PRESENTATIONS, NOTES, OR OTHER INFORMATION CONTAINED HEREIN, THE DESIGNER OF ALL CONFLICTS AND D15GREPANCIES THAT AFFECT THE WORK AND WRITTEN APPROVAL OF SAID AUTHORITY, THE CONTRACTOR NEITHER 15 LIABILITY ASSUMED FOR THE OUTCOME OF DECISIONS, CONTRACTS PRIOR TO PROCEEDING, SHALL BE RESPONSIBLE FOR ALL FEES RELATED TO THE I55UE OF 0 TYPE III category 2 COMMITMENTS OR OBLIGATIONS MADE ON THE BASIS OF THIS INFORMATION. PERMITS, INSPECTIONS AND CERTIFICATES NECESSARY FOR THE EXECUTION INFORMATION. SEE STRUCTURAL DWGS FOR ALL MTL g window schedule ne 5 ■ A R AND COMPLETION OF THE WORK AND THE OCCUPANCY OF THE AREA OF WORK BLDG *ELECTRICAL AND MECHANCAL ENMEMNG DOOR applic. int. pressure coeff. 18 THE GENERAL CONTRACTOR SHALL ADHERE 70 THE INDOOR AIR QUALITY RULES ELECTRICAL AND MECHANICAL INFORMATION CONTAINED IN THESE DRAWINGS ARE #IN THE EVENT THAT THE ADMINISTRATIVE AUTHORITY HAVING k RULES OF THE ADMINISTRATIVE AUTHORITY 102 TYPE SOLELY FOR THE PURPOSE OF COORDINATION OF THE ENGINEER"/DESIGNER'S WORK, AND REGULATIONS ACCORDING TO THE NATIONAL HEALTH ASSOCIATION JURISDICTION WITHHOLDS IT'S APPROVAL FOR ANY CAUSE THE HAVING JURISDICTION see door schedule WALL design wind pressure all windows and doors shall meet ELECTRICAL, MECHANICAL, AND PLUMBING DRAWINGS SHALL BE PROVIDED BY OTHERS AND (LE. NO HEAVY BODY VOGS). worse case scenario of -30 ps.f. SUBMITTED TO THE ADMINI5TRATIVE AUTHORITY HAVING JURISDICTION. CONTRACTOR SHALL IMMEDIATELY INFORM DESIGNER OF THE TYPE SITUATION ALONG WITH CORRECTIVE ACTION TO BE TAKEN. REFERENCE (D NOTE T U W O Q Ln wQ � o �Fy Q O WN (n JO J r7 _ a_ O w M N W J O _J LL] � O IL w W 1z N d Z Z O U M r` D N O v 0 �^ v Z O X O �000 Z "^ U Plan ZEPHYRHILLS Job # 2924 Date 8- 20- 08 Sheet A-100 i 1 _-1 A I I - __L LI 1 I'III tip I�#''I ; .. FIELD VERIFY THIS DIMENSIC W/ STAIR LEN AND DOOR AB MIN 4B". AND ALSO AVOID 1 ELEC BOXES 4 CONDUITS BEL FIELD VERIFY STAIR DIMENS PROVIDE TRIM FLASHING COVER EXPOSED EDGE C CUT PANEL 6" PIPE BOLLARDS IB" LEVEL SURFACE A STAIR PLAN SCALE: 1/4"=1'-0" 14'-10"± EXISTING TILT WALL PANELIlk ELEVATION A SCALE: 1/4" = P-O" B" REINFORCED WALL/CURB TO FOLLOW SLOPE OF RAMP. WITH 4 36"NIGH HAND RAIL (42" IF F.F. 200 HEIGHT IS ABOVBY E 24") SUPPLIED — — — — —OWNER RAMP DOWN TO EXISTING 14'-6" EXISTING RAMP DRIVE ENLARGED C RAMP AREA SCALE: 1/4"=V-0" REUSE GUARD RAIL WALL REINFORCMENT (3) # 4's LONGITUDINAL WITH #5's DOWELS OUT / B OF FTG. @ V-0" O.C. :4 0.f: 42" HIGH GUARDRAIL (TYP AT ALL PRE-FAB STEEL STAIR SYSTEM. ELEV ABV 24" PREFAB STEEL MANUF TO PROVIDE SIGNED AND SEALED SHOP DWGS \. EXISTING WALL \ � 4'-0" 7'-211± �\ o FIELD VERIFY TO AVOID \ s ELEC BOXES / CONDUIT BELOW FIELD - VERIFY THIS co DIM W/ ACTUAL ,� ' GRADE ELEV. MODIFY AS NEEDED. MAX 7" RISER 7" RISERS MAX. 4'-0" 11" TREADS MAX. CUT AND REMOVE 8'x10' HIGH AREA OF PANEL FOR NEW DOOR. PROVIDE ADEQUATE SHORING AS NEEDED EXISTING DOOR — AND STAIRS WITH HANDRAIL TO REMIAN 0 6" THICK 3000 PSI ■ o a_ REINFORCED WITH _! 6X6XW2.9XW2.9 RAMP/SLAB ' REINFORCMENT #4 x 12"xI6'L INTO SLAB @ 2'-0" O.C. TIE w EXISTING 6x6xW2.9xW2.9 WWF TO THESE HORIZONTALS. GRADE a EXISTING ` CONC. SLAB CLEAN AND COMPACTED FILL AS REQUIRED �V �p co 1'-4" (3) # 5's LONGITUDUNAL AND #4's TRANSVERSE @ 4' O.C. L iY o w �Q w U- STAIR SECTION BSCALE:1/4"=V-0" EXISTING ROOF SYSTEM TO REMAIN EXISTING STEEL FRAME/SYSTEM TO REMAIN. SEALWALL UP TO ROOF STRUCTURE AS NEEDED 6" 24ga MTL STUD WALL @ 16" O.C. W/ 1/2" GWB EACH SIDE AND R-11 BATT INSUL B" K.O. BLOCK W/ (1) #5 mi'**��CONT POURED SOLID NEW CMU WALL. SEE WALL LEGEND ON A-100 DRILL AND EPDXY A #5x12" DOWEL W/ 4" MIN EMBEDMENT INTO EXISTING SLAB @ B' MAX. O.C. 4 SECTION (DWsc,/- FIELD VERIFY THIS DIM W/ ACTUAL GRADE ELEV. MODIFY AS NEEDED. MAX 7" RISER 1 1/2" SCH.40 STEEL PIPE :LD ALL AROUND (TYP.) :OUND OR SMOOTH A5 ST 1 1/2' SCH.40 STEEL PIPE 1 1/2" SCH.40 STEEL PIPE RAILING CROSS-SECTION RAILING ELEVATION N.T.S. N.T.S. TYP. GUARDRAIL DETAIL SCALE: N.T.S. STAIRS TO AVOID EXISTING ELEC BOXES AND CONDUITS. FIELD SEAL UP AROUND EXISTING CONDUIT PENETRATING THRU FLOOR LEVEL EXISTING WALL SYSTEM TO REMAIN OWNER/CONTRACTOR TO REUSE EXISTING HANDRAIL. MIN HT. 42" FLOOR SYSTEM. SEE A-100 EXISTING CONC. SLAB AND FOOTER SYSTEM 2 WALL SECTION SCALE: ' ' `" ne'' 40 STEEL PIPE d a- ccn /B" WELDNT.CE)_"4"xB"xl/2" \EW CONT AN \ 3/4" dia x 7 1/2" EXP \ BOLTS @ 12" O.C. \ (STOP/START ANGLE @ \ CONDUIT PENETRATIONS) \ MISTING FLOOR SYSTEM TO ZEMAIN EXISTING WALL SYSTEM TO REMAIN EXISTING CONC. SLAB AND FOOTER SYSTEM cc Lo N Z X nCMMa5'-' DATE: 9-25-08 PER BLDG DEPT DATE: EXISTING MASONRY TREAD WALUDOOR NEW TREAD TO JAMB BEYOND MATCH EXISTING u m v Lo c o y A r _ TRANSITION N TOPPING FOR _c Lo OIL 100.33' r STAIR / ELEV 100.00' T a ELEV a" � I ' o 0 0 Ir J 71 % fA � FOOTER c OJ I ft- BEYOND r L` SECTION A -A a3 c � v 0 N 0 4- c 0 ` o c N QO L c E +' U u w A/C UNITS ON METAL RACK. SEE MECH DWI ME UNITS ON METAL RACK. SEE MECH DWGS 5T RISER TO DIFFER RISER D 4sc LAN LE: EXISTING ROOF SYSTEM TO REMAIN CLOSE IN RAFTER AS REQUIRED. LEAVE VOIDS FOR EXISTING PIPING AS v co v r I 00 c0 o '� 000 -on - .-, V) On x 0to "o � � L° Lo 00 ,q- 0 N 00 -c Z Quo Q v L. w m �� Q -0 N cc � �1, 04 to — Z v � O- � J 0 � Q Z ii O NEEDED AT EXISTING STEEL CLG �- FRAME/SY5TEM TO REMAIN PARTS W 1>7 NEW CONT. STUD ~ o STORAGE OFROOF M SY 5-2 OCCUPANCY #4 DOWEL � � CONT. Q Ir n - \ O — — - J r d \ W O V) 3-5/B' 20go MTL / #4 DOWEL @ 24' O.C. 1 o — STUD WALL @ 16' O.C. W/ 1/2' GWB --_-­., 16'x4 I/2'xl/4' I } EACH SIDE AND PLATE W/ '\ d R-II BATT INSUL Y/B' WELD ®� O N \ II 3 I/2' CONC AND METAL DECK SYSTEM W/ 3000 P.S.I CONCRETE WITH L \ ° / 4X4XW2.9XW2.9, C24 / i Bzl6 BOND BEAM DECKING — / W/ (2) #5 TOP — —`3.> �— — — AND BOTT CONT W/ #3 TIES @ 7= , - m \ 16, O.C. O > / FL00R w i SYSTEM. SEE A-100 STORAGE 5-2 OCCUPANCY (DSC!ALE: EXISTING CONC. SLAB FACTORY F-2 OCCUPANCY I \� NEW CMU WALL. SEE WALL LEGEND ON A-100 NEW C)NT. FOOTER WITH 3000 PSI CONC. AND (3) #5's CONT. O L.L Ld N U Z Z O U M n D � N o qk c U Z ewe � x -b ° Z N cG M s 10 00 Go O ® W coo Job # 2924 Date 8-20-08 sheet A-200 CONDENSATE DISCHARG GRADE REFRIGERANT PIPING UP TO ROOF TO CU-6 (TYP AHU-1 TO AHU-6) --- ----------------- T AHU-2 li AHU-3 T AHU-4 T ANU-5 T AHU-6 T — — — — — — J ANU-3 REFRIGERANT PIPING FROM EACH AHU-4 AHU-5 AHU-6 DOWN TO AHU-2 it AHU UP TO CONDENSING UNITS ON FIRST FLOOR FRESH AIR DUCT 84 UP ROOF (SEE ARCH DWGS FOR RACK 2" CONDENSATE DRAIN LINE 12' ABV TO ROOF CAP LOCTION) PIPING FOR AHU 1,2, 43 ON FLOOR -SLOPE TOWARDS AHU-2. PROVIDE (TYP-AHU-2 AND AHU-6) RACK I AND AHU-4, AHU-5, AND PIPE SUPPORTS AS REQUIRED AND AHU-6 ON RACK 2 TWO-WAY CLEANOUT @ EVERY 20'-0" MEZZ. ABOVE SCALE: 1/8" = P-O" CONDENSATE DRAIN GD(IM MC77AMIAIC FLOOR PLAN SCALE: 1/8" = P-0" FRESCH AIR DUCT FRESCH AIR DUCT ROOF CAP - DUCT 10'-0" 10'-0" ROOF CAP - DUCT TO AHU-2 min min TO AHU-6 CU-1,2,43 \_(I) CONDENSERS EACH END ON CU-4,5,V6 ROOFTOP RACKS. PROVIDE ANCHORS TO MEET CURRENT BUILDING AND MECHANICAL CODE. A/C g ROOF LEVEL SCALE: 1/32" = 1'-O" OVERALL PLAN SCALE: 1/128" = P-0" J O I I � o � 1 I I I �00�� I I I �I RV ON ROOF RSF-I BRD IN CEILING AND ON ROOF 1-0) CONNECTED TO RV WITH GALV. 1 DUCT. (SET @ 0.05" WG TO O OPEN AND RELIEVE THE PRESSURE) 18x18 I 1 I DUCT. I I I I I(Ox16 SUPPLY GRILLE ( TYP 3 SIDES) II O I_ FLOOR PLAN @ STORAGE ROOM SCALE: 3/16" = 1'-O" SPLIT SYSTEM A/C SCHEDULE AIR HANDLING UNIT DATA MARK - AHU 1-6 COOLING CAPACITY BTUH 55000 SENSIBLE CAPACITY BTUH 39000 SUPPLY .AIR CFM 1970 OUTSIDE AIR(FOR AHU-2 & 6 ONLY) CFM 200 ENTERING AIR TEMP. DB/WB 'F/'F 80/67 EYT. STATIC PRESSURE IN, H2O 0,5" _ �I ELECTRIC HEATER KN✓!STAGES 7.5/1 MOTOR HP 1.0 HP/7.6 AMPS ELECTRICAL V/PH/HZ 203/1/60 FILTER TYPE - I" THROW AWAY BASIS OF DESIGN (1) - YORK MODEL - F5FP060H06T2C NOTES - 2,3,4,6 E.E.R. - 13.0 CONDENSING UNIT DATA MARK - CU-1 TO 6 OUTDOOR TEMPERATURE 'F 95 ELECTRICAL V/PH/HZ 205-230/3/60 COMPRESSOR RLA/LRA 17.3/123 MCA/MOCP - 25/40 BASIS OF DESIGN ("1) - YORK MODEL - HIRD060525 NOTES - 4, 5, 7 (1) OR APPROVED EQUAL. (2) VERTICAL UNIT. WITH HORIZONAL DISCHARGE. PROVIDE ANGLE IRON FRAME WITH NEOPRENE PADDING BETWEEN UNIT AND FRAME_ (3) PROVIDE WITH DISCHARGE GRILLE AND ON/OFF/AUTO DUAL BAND T'STAT (4) VERIFY THE SIZE OF REFRIGERANT PIPING BASED ON THE LAYOUT AND LENGTH BETWEEN EACH AHU AND ITS RESPECTIVE CU. (5) PROVIDE ANCHORS FOP. CONDENSING UNIT TO WITHSTAND WIND LOAD PER BUILDING/MECHANICAL CODE. (6) PROVIDE SINGLE POINT POWER CONNECTION n (7) FURNISH WITH CONVINIENCE OUTLET. HyA, ( H 0 TE FAN AIND D;���MPEP S-CHED!_iEE MARI, RSF-1 RV 1 BRD-1 CFM 2500 2500 1- - -- EXTERNAL S.P. DRIVE TYPE C 25 DIRECT 0_D94 - MOTOR H.P. 1 0 - - R.P.M- 994 - - ELECTRICAL 120/1/60 - - BASIS OF DESIGN (3) GREENHECK GREENHECK GREENHECK MODEL SAF-110-10 FGP BR-10 ACCESSORIES DS,RC,BD,F,BS RC,BS,BD - NOTES 1,2,3 4 (1) FURNISH WITH WEATHER PROOF OUTSIDE AIR INTAKE HOOD (2) FURNISH WITH DUCT COLLAR (3) APPROVED OR EOUAL (4) FURNISH WITH Iv1GDEL WD-100-PB GRAVIT'r' OPERATE DAMPER (5) DAMPER START TO OPEN @ 0.05 IN IWG. VELOC.TY NUT TO EXCEED 2000 FT/I•AINI ABBREVATIONS- RSF - ROOF SUPPLY FAN Rv - RELIEF VENT BRD - BAROMETRIC RELIEF DAMPER PIPE FLASHING MUST NOT BE SUBJECTED TO TEMPERATURES ABOVE 300'F. EXPOSURE TO TEMPERATURES ABOVE 300' WILL RESULT IN FAILURE OF FLASHING MATERIAL. PIPE FLASHING TR FASTENERS @ 2' O.C. MAXIMUM ' RV-1 (SHOWN FOR CONTINUOUS BEAD CLARITY. SEE FLOOR OF TUBE CAULKING /j PLAN FOR LOCATION) CURB BY VENTILATION CONTRACTOR Z BOTTOM VIEW OF PIPE FLASHING I� PROVIDE SUPPORTS AT REVERY 5'-0" TO PREVENT I VIBRATIONS TO RSF-I SET @ 80'F ROOF PANEL----% PROVIDE FULL SIZE FIELD CUTj DUCT BETWEEN BRD \ HOLE \ AND RV ERECTION PROCEDURES 1) OPENINGS IN THE ROOF FOR SMALL DIAMETER PIPING SUCH AS VENTS MAY BE LOCATED ONLY IN THE FLAT OF THE PANEL. DO NOT CUT PANEL RIBS FOR ROOF PENETRATIONS. 2) CUT A NEAT HOLE IN ROOF PANEL WITH I' CLEARANCE FOR PIPE AND INSTALL PIPE. 3) RUBBER SLEEVE SHOULD BE A WATERTIGHT FIT ON PIPE. IF RUBBER HAS TO BE CUT TO SUIT PIPE SIZE, USE A SHARP PAIR OF SCISSORS AND AVOID NICKS. 4) APPLY TUBE CAULKING TO THE UNDERSIDE OF BASE AND USING WATER AS A LUBRICANT, SLIDE FLASHING ALING PIPE UNTIL IT MEETS ROOF PANEL. 5) PRESS BASE OF PIPE FLASHING FIRMLY AGAINST PANEL. 6) DRILL TWO HOLES OPPOSITE EACH OTHER AND FASTEN. PROGRESSIVELY COMPLETE THE FASTENING BY PRESSING BASE FIRMLY AGAINST PANEL TO AVOID GAPS. CXP ROOF PANEL DETAILS PIPE FLASHING INSTALLATION SCALE: N.T.S. 8'0 DUCT TO ROOF T-CAP (FOR AHU-2 FULL SIZE GRILLE ON AIR AND AHU-6 ONLY) DISCOF AHU OPENING AN- LOCATE LOCATE ROOF CAP MIN 10'-0' AHU AWAY FROM CONDENSING UNITS FIRE STAT �- REFRIGERANT PIPING AIR HANDLING FILTER (FRONT ACCESS) UP CU ON ROOF I UNIT PO SCH. 40 PVC 1' CONDENSTATE DRAIN. 1' CONDENSDATE DRAIN LINE WITH P-TRAP. DISCHARGE INTO NEOPRENE PAD BETWEEN CONDENSATE PIPE ALONG THE UNIT AND ANGLE IRON WALL (SEE PLAN FOR PIPE FRAME. LOCATION) I `J DISCHARGE TO CONDENSATE VJ—F-i—Ir DRAIN PIPE. SEE PLAN FOR � ISOLATORS. TYP. OF 4 ON GALVANIZED STEEL STAND. ANGLE BRACING WfFEE PROVIDE ANGLE BRACING AS PIPE LOCATION REQUIRED TO SUPPORT AHU AHU DETAIL (TYP) r F PAPDETAIL NO 'r ALE NO SCALE 1. ALL 'dVORK SHALL BE ACCOPDAN"E WITH HFPA C?O—A & B, HR�L '.;UIDE "�IgAI_:J'Jti' DIH T C:OfJ�-PU1,TI 'Il Aid'FDS, NrPA. I0I, EL 1PIDA _TATE EivEF' L)DE rLUPID A BUILDING � C)DE AND ALL D-.CAL CODE HA VIr• G JURISDICTl' P_) _. %/IDE A TF'.Ar' AT C'_1iJDEF1S'-TE ERA.IrI L'I<JE �IaNsrJECT'Gr,l AT ALL AIR HANDLIII(_l UNITS DRAIF1 LIME, ,HALL RE r:H. AC) P r, _L'_P__ TO PAINT Or DlSiCHARGE AT MIIJIfIUIU ' PER FurT_ 3 :ALL __ IIIpIv1EFJ1 SHALL BE U.L. D_;TED AND A P ERTIFIED A,-L V ED H,ANI AL EJI III^.4ENd 1 RE01 (Pill ELECTPl- AL /JER r E L 1 L- H �I C� i11 'EC.T Ti E T E, ,CH 0 n I � �F rI,IPP EI T CO RU IJFTE TWITCH PtIIFEN1ENTs H HE ELF Tk,��L rT�IT� ACT P. IT H ",!,i l T� HE .P_I'1SIE'1-ITi 'D '_ _C'CILj4TE LL ELE-T,EI PE_ IIPEMEP.T'7. LI'STE' FIPE _ ... T 1[ 1 ='JFPL IP F AL ^I J THE G .TE.IP INDICATED Ji'd THE DPANIIJC HALL BF Vn✓IGFL�TOF lFt AHU rANI PC ETE ,IG,,-jU"E J HE jH_ h,!;_ RIPE 'I APIvl STE" PLI 4ri E F 7H F l ILI�IIJS H O FIPt ALARM �TENs THE t'EC'(-,F,'HALL v U H_F L PJ A UDIBLE ]D VISUAL ALARI I It -I A I JKNIti Lt CI I IP,E_ PEA IIJSTALL Ilk E \vI.H THE -FIFE MAP'SHA.LL. 5 L L,T CIMLNSIONS _HC NF! APE C LEAP•. HI_IDE DIIvIE',ISII rJS 6. I-Et_)VIDE A FLEXIBLE '01`,II`JECIICI�`J BETWEEN P�F 1, DU(_-7 C"Rk LIJD 4:HU FFE H AIP DUCT- -' PPL C U T FROP.4 P`�F—1 `.HALL BE FABRICATELD I IF ACCESSOPIES GALVAi'JIZED SHEETIv1ETAL, WITH ALL SEAMS AND JOII"JTS SEALED US — DGCONNE^T '��dTCH — LIEM3 ti FTI ;HT PROVIDE-,LIPP0RTS AND.'-`,PJCHOP TO ADJ''�ETJT 'J;A,LL A� FULLi INEATZ PROOF H Jwhvi'l n EVER( 5 BG - B A,KDRAFT DAMPER RC — PJOFCHRB H qL'� "1O I[TTED THERM✓ STATS SHALL BE FC)CATEU A. MiNlIC1LIV, LLF —0­ F - I" WASHABLE ALUMINUM FILiFRS ABO'✓E FINISHED FLCIOR_ BS - BIRD SCBEErJ �J A.LL MFC-HAi'",JICAL ErULIIPNIEJT AND SYSTEMS SHALL BE GUARANTEED FOR A PERIOD OF OPJE TEAR AFTER WPITTEN 'CCEP IANCE BY CA"I'lER. HVAC COMPRESCPS SHALL HAVE AN A,DDIT10'vJAL FOUR—lE'P 'V_`PPa,NT'( 'I CD L L PFRiGEPAN'JT FIPIN� _ SHALL BE IN`LILATED WITH THICK APMAFLE? E000 GE EC_UAL. pP00IDE ALUM JACKET OF,J THE PIPIILG 0C, RCnF 11- PRE=WIDE T'STAT FOP RSF-1 WIPE TO STAPT/'STOP_ SET i�) 80`F 6 FRAME TO BE ANCHORED TO THE WALL USING 3/8' DROPS 114 ANCHORS'-' ° I a \" °< FRAME°CONSTRUCTION 2 xl/4' ANGLE. ALL WELDED CONST. °< ACU WALL RACK SCALE: 1/4" = V-0" 4 BRD-1 SET @ 0.05'WG 18XIB DUCT DC FROM RSF-I SUPPLY GRILLE I(PA6 ON THREE SIDES AS SHOWN ON PLAN ANGLE VENTS DOWN I t s f SETION A -A SCALE: 1/2" = 1'-O" f BY I ER HARISH SHAH, P.E. HVAC, PLUMBING, FIRE PROTECTION CONSULTING ENGINEER P.E. NO. 19880 LAKELAND, FL. 33813 PHONE/FAX: 863-619-8258 EMAIL — HHSHAHI®YAHOO.COM SIGNATURE PLANS NOT VALID UNLESS RAISED SEAL AFFIXED. REVISIONS: DATE: 9-25-08 PER BLDG DEPT DATE: mot- C C N O N c y C14 O � c # Lac 00.0 C � Q- r W 050 LLI C J LL- ra"4) 3 rn � j c 4 o a� b V c O c Y W CL O L =cE' -U uw LY �04 � N I 00 cfl L4 o 0000 a`0o `9 ML2 00 0 a N�00� z 4 Q L O Q L • ,\ a EL w �m Q 0 (LI a. N S co �m O� J F- 00 ao � _c O Z Q 0 U W �- Q L0 w Q �o V)o L J .4� ILL- WO N (/j J O -� r7 = 0 Ld N N m a) J_ O LL J LLJ _ O a. :�E W w N U Z LL' O Z cD "0 N M co WI I W`' z O C) Ne i .0 00 lal l Plan ZEPHYRHILLS ob Job 2924 Date 8-20-08 Sheet M-100 DRAIN SCHEDULE MARK OUTLET SIZE STRAINER SIZE MANUFACTURER'S NUMBERS NOTES JOSAM WADE ZURN FD-1 3" 8"X8" 30000-S W-1100-G Z-415-S NICKEL BRASS TOP PLUMDIl�G LEGIEl�D WASTE PIPJvJG VENT PIPING ---------------------- COLD WATER PIPNG, HOT WATER WPT,]G WASTE Vv VENT \✓ VENT THRIJ ROOF V T R COLD WATER C�PJ HOT WATER HW STORAGE ROOM FLOOR PLAN - SUPPLY SCALE: 1/4" = 1'-0" PLUMBING FIXTURE AND CONNECTION SCHEDULE P-NO FIXTURE MOUNTING MIN. CONNECTIONS SPECIFICATION DESCRIPTION HEIGHT NOTES WASTE CW HW MANUFACTURER FIXTURE TRIM WASTE TRAP SUPPLY P-1 LAUNDRY TUB, FLOOR 1 1/4" 1 /2" 1 /2" KOHLER (*) K-2005 - - - K-7715 K-9000 K-7606 PROVIDE FLOOR MOUNTED CARRIER BY JOSAM, WADE, (*) FLOOR TO RIM 31 OR ZURN IF MOUNTED ON STUD WALL ELJER (*) EQUAL --- 803-0552 804-1180 802-0320 MOUNTED/STAINLESS PROVIDE PREMOLDED PREINSULATED COVER FOR TRAP & SUPPLIES - CHICAGO FAUCETS(*) ---- - - - - 2200-4 327 - - - 1008 STEEL 20"x18" PROVIDE DRAIN OFFSET TO PROVIDE HANDICAP CLEARANCE P-2 EMERGENCY FLOOR TO 1 1/ " 1/2" --- BRADLEY (*) S-19-310PVC --- --- - - - - - - PROVIDE 1-1/4" P-TRAP FOR EYEWASH SHOWER AND TOP OF & EYEWASH NOZZ. 42" HAWS EQUAL - - - --- 1, P-3 INSTANTANEOUS BELOW --- 3/8" 3/8" POWERSTREAM AE3.4 (RP3) - - - - - - - - - --- PROVIDE WITH 3.OKW - 120V-lPH-60HZ HEATING ELEMENT ELECTRIC WATER P-1 AND BALL VALVE IN CW INLET HEATER P-4 LIFT PUMP IN FLOOR "1 IIN4 - - - - - - HYDROMATIC (*) SHEF50 - - - - - - - - - --- PROVIDE WITH HYDROMATIC 224 BASIN, 224 SEAL KIT AND 224 1 COVER. PUMP CAPACITY 40 GPM @ 40 FT. HEAD. OUT 1/2HP-12OV-1PH-60 HZ-14.5 AMPS. PUMP SHALL HAVE INTERGAL FLOAT SWITCH. EX IEND 1 1/4-- SCHEDI 40 FORCE MAIN TO NE BUILDING DRAIN AND t CONNECTION. VERIFY E LOCATION IN FIELD 01 (*) OR CONTRACTORS CHOICE STORAGE ROOM FLOOR PLAN - WASTE SCALE: 1/4" = V-0" PLUMBING NOTES 1. ALL PLUMBING WORK SHALL BE IN ACCORDANCE WITH FLORIDA 2004 CODE (LATEST EDITION) INCLUDING THE 2005 AND 2006 SUPPLEMENTS AND ALL LOCAL CODES. 2. DOMESTIC WATER PIPING SHALL BE TYPE 'L' COPPER WITH 95-5 (TIN -ANTIMONY) SOLDER JOINTS. SCHEDULE 40 CPVC WITH SOLVENT JOINTS MAY BE USED WITH THE APPROVAL OF THE LOCAL BUILDING DEPARTMENT AND OWNER 3. WASTE AND VENT PIPING SHALL BE SCHEDULE 40 PVC WITH SOLVENT JOINTS EXCEPT PIPING IN RETURN AIR PLENUMS SHALL BE NO -HUB CAST IRON WITH NO -HUB SLEEVE AND CLAMP JOINTS. 4. LOCATE P-4 AT ACCESIBLE LOCATION FOR MAINTENANCE. 1-1,zl' MAll i WASTE RISER DIAGRAM NO SCALE HARISH SHAH, P.E. HVAC, PLUMBING, FIRE PROTECTION CONSULTING ENGINEER P.E. NO. 19880 LAKELAND, FL. 33813 PHONE/FAX: 863-619-8258 EMAIL - HHSHAH1®YAHOO.COM REVISIONS: DATE: 9-25-08 PER BLDG DEPT I1L•1I9 0 Col n N L o0 ® 0 Lo OO s t0 # 0 6 C �p CIL 0. �= — U U m u)O lJJ OL _ 3 O Op 13 J c _c O U a U c O � n Y N CL L UW -U � o� 0 LL J Ld 0 O 12 Ld af 1 q- I N 00 Qp (O ID 1, 4 1 O \v 00 CD (n 00 v 3v N O.E Z Q to v� w m ,�, Q a Iry N c a N V > \ V v r' 01) O v � U m Q F- S � z p' UI Z nQ LPL 2 O U o� w '04- F_ L u F-o 0 V)o ° s� w0 N (n J O � 2 a- 0 w N V♦ J o� r I.L w N U Z Z `o_ 1 U M r 04 N O U U n r U V/ Z O U or .. x 0 � w e p G Z v C� N 0 M to ®� f.w 'l W Lo� \ 0 UJ a0 v 0 ZEPHYRHILLS .lob # 2924 SIGNATURE DATE: PLANS NOT VALID UNLESS RAISED SEAL AFFIXED. Date 8-20-08 Sheet P-100- REVISIONS: DATE: 9-25-08 PER BLDG DEPT DATE: ABBREVIATIONS A AMPERE AF AMPERE FRAME AFF ABOVE FINISHED FLOOR AFG ABOVE FINISHED GRADE AHU AIR HANDLING UNIT AL ALUMINUM ATS AUTOMATIC TRANSFER SWITCH AWG AMERICAN WIRE GAUGE C CONDUIT CAT CATEGORY CB CIRCUIT BREAKER CH CHILLER CKT CIRCUIT CL CENTER LINE CLG CEILING CU COPPER DWG DRAWING EC ELECTRICAL CONTRACTOR EF EXHAUST FAN EM EMERGENCY EMT ELECTRICAL METALLIC TUBING ENCL ENCLOSURE EWH ELECTRIC WATER HEATER EXIST, EX EXISTING FA FIRE ALARM FCP FIRE ALARM CONTROL PANEL FACC FIRE ALARM COMMAND CENTER FATC FIRE ALARM TERMINAL CABINET FO FIBER OPTIC GFI GROUND FAULT CIRCUIT INTERRUPTER GND,G GROUND HOA HAND -OFF -AUTO HACR HEATING/AIR CONDITIONING -RATED HID HIGH INTENSITY DISCHARGE HPF HIGH POWER FACTOR HPS HIGH PRESSURE SODIUM HP HORSEPOWER IG ISOLATED GROUND JB JUNCTION BOX KCMIL THOUSAND CIRCULAR MILS KVA KILOVOLT AMPERE KW KILOWATT MCB MAIN CIRCUIT BREAKER MCC MOTOR CONTROL CENTER MDP MAIN DISTRIBUTION PANEL MH METAL HALIDE MLO MAIN LOAD ONLY MTD MOUNTED NC NORMALLY CLOSED NEC NATIONAL ELECTRICAL CODE NEMA NATIONAL ELECTRICAL MANUFACTURERS ASSOC. NF NON -FUSED NFPA NATIONAL FIRE PROTECTION ASSOCIATION NIC NOT IN CONTRACT NIL NIGHT LIGHT NO NORMALLY OPEN PNL PANEL 0 PHASE PB PUSHBUTTON PVC POLYVINYL CHLORIDE CONDUIT RGC RIGID GALVANIZED STEEL CONDUIT SW SWITCH SWBD SWITCHBOARD TVSS TRANSIENT VOLTAGE SURGE SUPPRESSOR TS TIME SWITCH XFMR TRANSFORMER TYP TYPICAL UG UNDERGROUND UH UNIT HEATER UPS UNINTERRUPTIBLE POWER SUPPLY LON UNLESS OTHERWISE NOTED VAV VARIABLE AIR VOLUME VFD VARIABLE FREQUENCY DRIVE V VO LT Ili9• g1_11a1:ia 101161411 LIGHTING LEGEND 1 a CEILING MTD. 2'x4' LIGHT FIXTURE (SEE SCHEDULE) A❑° a CEILING MOUNTED 2'x2' LIGHT FIXTURE (SEE SCHEDULE) A a CEILING MOUNTED LIGHT FIXTURE (SEE SCHEDULE) 1 a WALL MOUNTED LIGHT FIXTURE (SEE SCHEDULE) A O a CEILING MOUNTED LIGHT FIXTURE (SEE SCHEDULE) A Q ° WALL MOUNTED LIGHT FIXTURE (SEE SCHEDULE) 1 ❑ a CEILING MOUNTED LIGHT FIXTURE (SEE SCHEDULE) A pa WALL MOUNTED LIGHT FIXTURE (SEE SCHEDULE) A f---Q--{ a FLUORESCENT STRIP (SEE SCHEDULE) A-- 60 POLE MOUNTED LUMINAIRE (SEE SCHEDULE) 10-o-0 2 HEAD POLE MOUNTED LIGHT FIXTURE (SEE SCHEDULE) 1 3 HEAD POLE MOUNTED LIGHT FIXTURE (SEE SCHEDULE) A40 1 4 HEAD POLE MOUNTED LIGHT FIXTURE (SEE SCHEDULE) A EXIT LIGHT EXIT LIGHT AND EMERGENCY LIGHT COMBO A EMERGENCY LIGHTING FIXTURE WITH BATTERY BACK-UP (SEE SCHEDULE) A o 0 o a TRACK LIGHT. NUMBER OF HEADS AS SHOWN (SEE SCHEDULE). LIGHTING CONTROLS M ,a SINGLE SINGLE POLE SWITCH 20A 277V UON CENTERLINE MOUNTED 48" AFF K: KEY TYPE M: MOTOR RATED S2 DOUBLE POLE 20A 240V SWITCH - UON CENTERLINE MOUNTED 48" AFF S3 THREE WAY 20A 277V SWITCH - UON CENTERLINE MOUNTED 48" AFF S4 FOUR WAY WALL MOUNTED SWITCH - UON CENTERLINE MOUNTED 48" AFF Sp DIMMER SWITCH - UON CENTERLINE MOUNTED 48" AFF Ts I TIME SWITCH AS INDICATED. UON MOUNT TOP OF ENCLOSURE 66" AFF o5 CEILING MOUNTED OCCUPANCY SENSOR. SEE SPECIFICATIONS os WALL MOUNTED OCCUPANCY SENSOR. UON CENTERLINE MOUNTED 48" AFF GENERAL NOTES 1. TEXT SHOWN ON PLANS ADJACENT TO LIGHTING FIXTURES SHALL DENOTE THE FOLLOWING: LOWERCASE LETTER (BY FIXTURE OR SWITCH) INDICATES LIGHT SWITCH CONTROL. UPPERCASE LETTER INDICATES FIXTURE TYPE. NUMERAL INDICATES BRANCH CIRCUIT NUMBER. 2. SHADED LIGHTING FIXTURE SYMBOLS THAT APPEAR ON PLANS INDICATE EMERGENCY LIGHTING FIXTURES AND SHALL BE INTERPRETED AS FOLLOWS: LIFE SAFETY BRANCH CIRCUIT: CRITICAL BRANCH CIRCUIT: EMERGENCY LIGHT FIXTURE WITH BATTERY BACK UP: (THE ABOVE SHALL APPLY TO ALL LIGHTING FIXTURE SYMBOLS SHOWN ON LEGEND). 3. NUMERALS SHOWN ON PLANS ADJACENT TO WIRING DEVICES INDICATE BRANCH CIRCUIT NUMBER(S). 4. STANDARD SYMBOLS SHOWN ON LEGEND MAY NOT ALL APPEAR ON PLANS. WHERE SYMBOL APPEARS ON PLANS FURNISH AND INSTALL AS SPECIFIED. 5. ALL STANDARD SYMBOLS ON LEGEND THAT APPEAR ON PLANS WITH HIDDEN LINES SHALL BE EXISTING TO REMAIN (FOR REFERENCE ONLY). EXISTING SYMBOLS (AS DESCRIBED ABOVE) THAT APPEAR ON PLANS WITH AN ADJACENT ABBREVIATION SHALL BE INTERPRETED AS FOLLOWS: RL = EXISTING TO BE RELOCATED (SHOWN AT EXISTING LOCATION ON DEMOLITION PLAN), REFER TO INSTALLATION PLAN FOR NEW LOCATION. CONTRACTOR SHALL EXTEND WIRING TO NEW LOCATION AND RECONNECT. R = EXISTING TO BE REMOVED. CONTRACTOR SHALL REMOVE DEVICE AND/OR EQUIPMENT AND UNLESS OTHERWISE NOTED REMOVE ALL UNUSED CONDUIT AND WIRING. 6, ALL INSTALLATIONS SHALL COMPLY WITH LEED FOR NEW CONSTRUCTION VERSION 2.2 OCT. 2005 AND COMPLY WITH NEC AND APPLICABLE LOCAL CODES. POWER LEGEND HOMERUN TO PANEL INDICATED (CONCEALED). MINIMUM 3/4"C. UNLESS OTHERWISE NOTED PROVIDE #12 CONDUCTORS AS REQUIRED BY NUMBER OF CIRCUITS SHOWN. INCLUDE #12 GROUND AND #12 NEUTRAL LP- 1 CONDUCTORS. FOR HOMERUNS EXCEEDING 100' IN LENGTH PROVIDE #10 CONDUCTORS IN LIEU OF #12 AS INDICATED ABOVE, THERE SHALL BE A MAXIMUM OF 3 BRANCH CIRCUITS PER HOMERUN (AS INDICATED ON PLANS). TEXT SHOWN BY HOMERUN INDICATES PANELBOARD DESIGNATION AND CIRCUIT NUMBER(S). CONDUIT CONCEALED IN WALL OR ABOVE CEILING SPACE. UNLESS OTHERWISE NOTED PROVIDE #12 CONDUCTORS AS REQUIRED BY NUMBER OF CIRCUITS SHOWN. INCLUDE #12 GROUND AND #12 NEUTRAL. MINIMUM 1/2"C. UNDERGROUND CONDUIT OR BELOW SLAB. UNLESS OTHERWISE NOTED — - — PROVIDE #12 CONDUCTORS AS REQUIRED BY NUMBER OF CIRCUITS SHOWN. INCLUDE #12 GROUND AND #12 NEUTRAL. MINIMUM 3/4"C. - - - - - - EXISTING CONDUIT. AS INDICATED. P UNDERGROUND POWER DUCT BANK, AS INDICATED. C UNDERGROUND COMMUNICATIONS DUCT BANK. AS INDICATED. OH OVERHEAD LINE. AS INDICATED. MH i MANHOLE. SEE SPECIFICATIONS. HH HAND HOLE. SEE SPECIFICATIONS. i Q CEILING OR WALL MOUNTED JUNCTION BOX. UON SIZE AS REQUIRED BY NEC. FLOOR MOUNTED JUNCTION BOX. UON SIZE AS REQUIRED BY NEC. �. MOTOR. AS INDICATED. Tvss TRANSIENT VOLTAGE SURGE SUPPRESSION AS INDICATED El SINGLE PUSHBUTTON. UON CENTERLINE MOUNTED 48" AFF PP PUSH PLATE. UON CENTERLINE MOUNTED 48" AFF 480/277V, PANELBOARD. G 208/12OV, PANELBOARD. 208/12OV, DISTRIBUTION PANELBOARD. 480/277V, DISTRIBUTION PANELBOARD. 6 MISCELLANEOUS PANELBOARD, AS INDICATED. T DRY TYPE TRANSFORMER. AS INDICATED. HEAVY DUTY DISCONNECT SWITCH, NON FUSIBLE. SEE SPECIFICATIONS. UON MOUNT TOP OF ENCLOSURE 66" AFF HEAVY DUTY FUSIBLE DISCONNECT SWITCH. FUSED AS INDICATED ON PLANS. SEE SPECIFICATIONS. UON MOUNT TOP OF ENCLOSURE 66" AFF. HEAVY DUTY FUSIBLE COMBINATION STARTER/DISCONNECT SWITCH. SEE SPECIFICATIONS. UON MOUNT TOP OF ENCLOSURE 66" AFF. B MAGNETIC MOTOR STARTER. UON MOUNT TOP OF ENCLOSURE 66" AFF. SEE SPECIFICATIONS. ® VARIABLE FREQUENCY DRIVE AS INDICATED. UON MOUNT TOP OF ENCLOSURE 72" AFF ENCLOSED CIRCUIT BREAKER. AS INDICATED, SINGLE RECEPTACLE. 20A 120V LION CENTERLINE MOUNTED 18" AFF DUPLEX RECEPTACLE. 20A 120V UON CENTERLINE MOUNTED 18" AFF DUPLEX RECEPTACLE. 20A 120V UON CENTERLINE MOUNTED 42" AFF 50A 10 240V RECEPTACLE. UON CENTERLINE MOUNTED 18" AFF DOUBLE DUPLEX RECEPTACLE OUTLET. 20A 120V UON CENTERLINE MOUNTED 18" AFF. DOUBLE DUPLEX RECEPTACLE OUTLET. 20A 120V ION CENTERLINE MOUNTED 42" AFF. ® SPECIAL RECEPTACLE, AS INDICATED. UON CENTERLINE MOUNTED 18" AFF. ® FLOOR MOUNTED DUPLEX RECEPTACLE. FLOOR MOUNTED DOUBLE DUPLEX RECEPTACLE. 0 FLOOR MOUNTED COMBINATION (20A 120V) DUPLEX RECEPTACLE/DATA COMMUNICATION OUTLET. O 0 FLOOR MOUTNED COMBINATION (20A 120V) DOUBLE DUPLEX RECEPTACLE/DATA COMMUNICATION OUTLET. MULTI OUTLET STRIP OR POWER/DATA COMMUNICATION RACEWAY AS INDICATED. B B BUSWAY. SEE SPECIFICATIONS. DUCT HEATER. (FURNISHED UNDER DIV. 15). (WIRED UNDER DIVISION 16). i I RISER SYMBOLS LEGEND ELECTRICAL SPECIFICATIONS 1; ALL WORK SHALL BE IN ACCORDANCE WITH NATIONAL ELECTRICAL CODE AND SHALL ALSO COMPLY WITH ALL APPLICABLE RULES AND REGULATIONS OF LOCAL AND STATE LAWS AND ORDINANCES. GROUND FAULT SENSOR Lc) 2. ALL CONDUCTORS SHALL BE COPPER, CONDUCTOR INSULATION SHALL BE DUAL TYPE THHN/THWN 75'C. L (167' F.) FOR DRY, DAMP AND WET LOCATIONS. CONDUCTOR INSULATION WITH SINGLE TYPE MARKING L �' THHN 90' C. (194' F.) MAY BE USED FOR DRY LOCATIONS ONLY. ALL CONDUCTORS SHALL BE COLOR # b CODED AS REQUIRED BY NEC 3 ry co Jl CIRCUIT BREAKER. AS INDICATED THE COLOR CODE ASSIGNED TO EACH PHASE WIRE SHALL BE CONSISTENTLY FOLLOWED THROUGHOUT. co W �LL_ CC v� 3; UNLESS OTHERWISE NOTED ALL CONDUCTORS SHALL BE RUN IN ALUMINUM IN CHEM ROOM AREA AND a 3 a' AND RCS (RIDGID GALV. STEEL) IN MEZZ. AREA. CONDUIT SHALL BE UNDERWRITERS' APPROVED GALVANIZED 6 S ELECTRICAL METALLIC TUBING. COUPLINGS AND CONNECTORS SHALL BE STEEL, HEX -NUT, EXPANSION -GLAND MU c: o L o C / TYPE, ZINC OR CADMIUM PLATED. a o DRAWOUT CIRCUIT BREAKER. AS INDICATED E I C3 0 W 4O ; THE INTERIOR ELECTRICAL SYSTEMS SHALL BE COMPLETELY AND EFFECTIVELY GROUNDED AS REQUIRED BY NATIONAL ELECTRICAL CODE. ALL METALLIC RACEWAYS SHALL BE MECHANICALLY AND ELECTRICALLY SECURE AT ALL JOINTS AND AT ALL BOXES, CABINETS, FITTINGS AND EQUIPMENT. ALL RACEWAYS L SHALL BE PROPERLY ALIGNED, GROUPED AND SUPPORTED AT INTERVALS NOT EXCEEDING 8 FEET. T STARTER / CONTACTOR EXISTING RACEWAYS TO REMAIN SHALL BE RESUPPORTED WHERE RACEWAY SUPPORTS EXCEED 8 m r- FEET. ^ ono OG GENERATOR 5; COVER PLATES FOR FLUSH OR SURFACE MOUNTED WALL BOXES SHALL DUPLICATE EXISTING DEVICES IN SIMILAR PLANT AREAS. E co co b 6; ALL NEW OUTLET BOXES SHALL BE RIGIDLY MOUNTED AND SHALL BE EQUIPPED WITH SUITABLE SCREW Lo o x SWITCH FASTENED COVERS. � 0r ,° 00 0 3 N Z �l p • ' OUTLET BOXES SHALL TYPE FS CAST IRON. NEW AND EXISTING OUTLET BOXES INCLUDING k o E Q COVERPLATE OF DUPLEX RECEPTACLES SHALL BE IDENTIFIED WITH BRANCH CIRCUIT NUMBER OFcu w m m CIRCUIT TERMINATED WITHIN. N a v THERMAL OVERLOAD ELEMENT 7, THE CONTRACTOR SHALL REMOVE ALL EXISTING WIRING AND EQUIPMENT MADE UNNECESSARY BY THE Q�j "o O NEW INSTALLATION. ALL MATERIALS REMOVED SHALL BE DISPOSED OF BY THE CONTRACTOR. .Q � „ 8, UPON COMPLETION OF WORK CORRECT ALL PANELBOARD CIRCUIT DIRECTORY CARDS TO REFLECT j 00 Q RECORD CONDITIONS. s o a U TRANSFORMER 9; WHERE EXISTING RECEPTACLES ARE SHOWN TO BE REMOVED FROM PARTITIONS BEING REMOVED, CONTRACTOR SHALL MAINTAIN SERVICE TO REMAINING OUTLETS. 10. ALL RACEWAYS WITH NO. 10 OR 12 AWG PHASE CONDUCTORS FOR RECEPTACLES, LIGHTING FIXTURES AND SIMILAR CIRCUITS SHALL BE PROVIDED WITH A PARITY SIZED GREEN EQUIPMENT GROUND Z FUSE CONDUCTOR. GROUND CONDUCTOR SHALL BE INSTALLED IN ENTIRE RACEWAY SYSTEM INCLUDING WALL TT I SWITCHES AND FLEXIBLE CONDUIT TO LIGHT FIXTURES. EQUIPMENT GROUND CONDUCTOR SIZES FOR n CIRCUITS WITH PHASE CONDUCTORS LARGER THAN NO. 12 AWG ARE INDICATED ON DRAWINGS. GROUND GROUND CONDUCTORS SHALL BE CONNECTED TO GROUND BUSS IN PANELBOARDS. 11. LIGHTING FIXTURES: 0 Q­ RELAY COIL, NOTED WITH TEXT A, THE CONTRACTOR SHALL FURNISH AND INSTALL COMPLETE IN ALL RESPECTS ALL LIGHTING FIXTURES j U LISTED IN THE FIXTURE SCHEDULE. B. THE CONTRACTOR SHALL SUBMIT CATALOG CUTS OF ALL THE FIXTURES TO THE GENERAL '�' I b CONTRACTOR. W o FUSED SWITCH "' C, BALLASTS FOR FLUORESCENT LAMPS SHALL BE HIGH POWER FACTOR TYPE AND SHALL BEAR THE CBM, w ETL, AND UL LABELS. ALL BALLASTS SHALL BE UNDERWRITERS' CLASS P. BALLASTS SHALL BE w Q 0 TRIAD-UTRAD "BALLASTAR". ALL BALLASTS FOR FLUORESCENT FIXTURES SHALL BE INDIVIDUALLY ac FUSED. FUSES SHALL BE INSTALLED ON THE LINE SIDE OF THE BALLAST. Q o J �LL_ D, T-8 AND T-5 BULB FLUORESCENT LAMPS SHALL BE INSTANT START, OCTRON CR175 WITH A o AUTOMATIC TRANSFER SWITCH CORRELATED COLOR TEMPERATURE OF 3100K. ALL COOL WHITE LAMPS SHALL BE AS MANUFACTURED J N C BY SYLVANIA OR G.E. E, ALL FIXTURES SHALL BE PROPERLY AND CAREFULLY SUPPORTED AND ALIGNED, AND THE CONTRACTOR SHALL FURNISH AND INSTALL ALL NECESSARY STEEL SHAPES, ETC., FOR SUPPORT OF FIXTURES AS = REQUIRED AND DETAILED ON THE DRAWINGS. LIGHTING FIXTURES SHALL BE CLEAN AND LAMPED WITH w OM METER SOCKET NEW LAMPS AT THE TIME OF FINAL INSPECTION. 0 N m � r^ VJ TJ 2 O J Li ^_ O �.L w W N RICHARD P. CHRUSZCZ, P.E. FLTE LIC. #40080 U Z M r 04 N 0 U 0 U o (oco Q W NM t0 W °° °° O U � M c0 t0 °° ov Plan ZEPHYRHILLS Job # 2924 Date 8-20-08 Sheet E-100_ ANU-2 AHU-3 ANU-4 ADD EMERGENCY Al LITE I 4 1! 3 U -14,16 LI-6,8 2 L1-10,12 DOOR REQUIRES ELECTRIC CARD READER ANU-I DISCONNECT 60A 3 POLE, F 240 VOLTS NEMA I Li -2, 4 — L1-30 LI-36 cl III ill Mill IM111111111 11111 DOOR REQUIRES ELECTRICr 1 CARD READER. L1-32 �i DOOR REQUIRES ELECTRIC CARD READER NOTE: EXIT/EM LIGHTS SHALL BE NOTE: ELECTRICAL CONTRACTOR SHALL COORDINATE ELECTRICAL CONNECTED TO UNSWITCHED LEG OF REQUIRMENTS FOR (2) CARD READERS WITH SECURITY LOCAL LIGHT CIRCUIT CONTRACTOR. DOORS FOR EGRESS W/ ELECTRONIC LOCKS (SWIPE CARDS) SHALL RELEASE UPON FIRE ALARM ACTIVATION. 1 ELECTRICAL FLOOR PLAN SCALE: 1/8" = 1'-O" LI-26 u LI-34 DISCONNECT 30A I POLE NEMA 1120V FIELD LOCATE NOTES: 1) EXISTING 3000 AMP SWITCHBOARD #TI-MC5-080 2) NEW 75 KVA DRY TYPE TRANSFORMER #T3 3) NEW 225A PANELBOARD #LI-T3-DP-080 4) DISCONNECT (TYPICAL OF 6) 30 AMP, 2 POLE, 240 VOLT NEMA 1 NOTE: INSTALL CORD AND PLUG ON SINK RAIN LIFT PUMP LI-14 GFI (��C,�• 1 n - DISCONNECT 30 AMP 1-POLE NEMA I EA I I I I — I I = I I III I LI-3 I � LI-5 WP_ - _._ : I : T'r -_LLB T EMERGENCY/EXIT FIXTURE SHALL ON ROOF BE CONNECTED TO UNSWITCHED LIGHT OF IOCAL LIGHT CIRCUIT ELECTRICAL MEZZ. PLAN SCALE: 1/8" = V-0" CHEMICAL STORAGE ROOM POWER/LIGHTING PLAN SCALE: 1/8" = 1'-0" NOTE: RUN CONDUIT UNDER ROOF BETWEEN RECEPTICALES CU-1 CU-2 CU-3 LI-1,3,5 L1-13,15,17 AHU-5 LI-18,20 LTGHTTNG FIXTURE SCHEDULE iYPI �kAP1ii "Rk 1l�3LTAd� LAMPS(ea fixture) 'D SCSI _u._."1 ...... M . #40L.OPHANE HIGH A HOL OPPANE H4R64CTCACSX46k.MU 1210 V SAY FLUORESCENTS .................6;T,55,.... HdE.DP1dAh3� Hi�N $ HOi.OPHANkE HR$4X"T7•JNNUl044£P11 120 V 4=t8 $fY P3 L1fJS2ESCFh1? S _.. ... H�'}LC3PH�+Ik FX �� c HQLOPHANt m5ID L 30ININPSIM`NN 12G b' GG7-11.90 NOTE: ELECTRICAL CONTERACTOR PLEASE USE COOL WHITE LAMPS. CU-4 CU-5 CU-(o LI-25, 27, 29 LI-19,21,23 LI-31,33,35 NOTES: 1) DISCONNECT (TYP. OF 6) 60 AMP, 3 POLE, 250 VOLT5 RATED NEMA 3R 2) DECK TITES FOR 4 CONDUIT ROOF PENETRATIONS (TYP. OF 2) (REFER TO DETAIL) - (ELECTRIC CONTRACTOR SHALL FIELD COORDINATE PITCH AND PAN INSTALLATIONS NWP LOCATION WITH MECHANICAL CONTRACTOR) 3) SERVICE RECEPTACLES (2) DUPLEX WITH WEATHER PROECTED COVER 20A, 120V, GFI ELECTRICAL AND POWER ROOF PLAN SCALE: 1/8" - P-O" AHU-6 LI -22, 24 DOOR REQUIRES ELECTRIC CARD READER ol�f- 1 ADD EMERGENCY PIPE FLASHING MUST NOT BE SUBJECTED TO TEMPERATURES ABOVE 3007. EXPOSURE TO TEMPERATURES ABOVE 300' WILL RESULT IN FAILURE OF FLASHING MATERIAL. PIPE FLASHING TR FASTENERS @ 2" O.C. MAXIMUM CONTINUOUS BEAD OF TUBE CAULKING I ERECTION PROCEDURES 1) OPENINGS IN THE ROOF FOR SMALL DIAMETER PIPING SUCH AS VENTS MAY BE LOCATED ONLY IN THE FLAT OF THE PANEL. DO NOT CUT PANEL R155 FOR ROOF PENETRATIONS. 2) CUT A NEAT HOLE IN ROOF PANEL WITH I" CLEARANCE FOR PIPE AND INSTALL PIPE. 3) RUBBER SLEEVE SHOULD BE A WATERTIGHT FIT ON PIPE. IF RUBBER HAS TO BE CUT TO SUIT PIPE SIZE, USE A SHARP PAIR OF SCISSORS AND AVOID NICKS. 4) APPLY TUBE CAULKING TO THE UNDERSIDE OF BASE AND USING WATER AS A LUBRICANT, SLIDE FLASHING ALING PIPE UNTIL IT MEETS ROOF PANEL. 5) PRESS BASE OF PIPE FLASHING FIRMLY AGAINST PANEL. 6) DRILL TWO HOLES OPPOSITE EACH OTHER AND FASTEN. PROGRESSIVELY COMPLETE THE FASTENING BY PRESSING BASE FIRMLY AGAINST PANEL TO AVOID GAPS. CXP ROOF PANEL DETAILS PIPE FLASHING INSTALLATION SCALE: N.T.S. RICHARD P. CHRUSZCZ, P.E. FL.PE LIC. #40080 REVISIONS DATE: 9-25-08 PER BLDG DEPT DATE: r C T 3 c 0 .L N U C fA J C � 00 U c 0 c 0-0 c E1� oo�6 U UW n oD si- I 00 ID i 0 00 X 6 L� Z nQ {.L O U wo Q � Ld w¢ QO �o 4� W0 N Uj JJ O J O a_ LLJ N N m m J J O LL ` J W i O IEL w W Of N Z O F— Ln r D � a F— U C� ♦^ U Z O U or w Z w w �Job# 2924 Date 8-20-08 Sheet E-200 REVISIONS: DATE: 9-25-08 PER BLDG DEPT DATE: 160 MVA 13800V UTIL 13800 V/6.69 kfl 468 Vi5838 kA 446 V%3,16 kA N v MEZZANINE AREA ELECTRICAL DIAGRAM SCALE: N.T.S. 186 " 3126 kA 480 V- RISER DIAGRAM NOTES: FDRl, 1 Run, 1/C, THWN, Cu, 400 ' 208Y/120 V 1, EXISTING 15 KV PEC PRIMARY FEEDER. 3 - AWG 2. EXISTING PROGRESS ENERGY CORP (PEC) TRANSFORMER 1 - WG (2500 KVA PAD-MOUNT-58,388 AIC) (Ti PER INFO FROM MR. DALE KIBBY) PEC 12 MONTH LOAD HISTORY SHOWS PEAK OF 1 - WG 1083 KW (OR 1303 AMPS) ON 9/20/07 FLA FOR 2500 KVA IS 3015 AMPS FDR2, 1 Run, 1/C, THWN, Cu, 400 3. EXISTING SECONDARY FEEDER-3000 AMP FEEDER 480/277 3 - 4/0 AWG VOLT 3 PHASE 4 WIRE 4. EXISTING GE SPECTRA SWITCHBOARD 3000 AMPS WITH 1 - 4/0 AWG 3000 AMP MB,100 KAIC, TAG # T1-MCB-080 5. ADD 100 AMP FEEDER BREAKER TO SPARE SPACE 3 POLE 1 - 4 AWG 480 VOLTS 100 KAIC 4 .� PD r3-DPo82 6. NEW 100 AMP FEEDER 1-1 '/2 INCH EMT CONDUIT WITH 3- 174 kA #3 AWG CU AND 148 CU GRD 7. NEW 75 KVA DRY TYPE TRANSFORMER NEMA 1 480-120/208 VOLTS THREE PHASE INSTALL NEW TAG # T3 8. TRANSFORMER SERVICE GROUND CONDUCTOR #2 CU ATTACH TO EXISTING BUILDING STEEL. 9. NEW 225 AMP FEEDER 1-2 Yz " EMT WITH 4- #4/0 CU AND 1- #4 CU GRD 10, NEW 225 AMP MB GE SPECTRA PANEL 225 AMP MAIN BREAKER 42 SPACE 120/208 VOLTS 3 PH, 4 W.10 KAIC RATING, NEMA 1 SURFACE MOUNT WITH GROUND BAR KIT. ALL MEZZANINE AREA COPPER BUS. INSTALL NEW TAG # L1-T3-DP-080 11. INSTALL NEW TRANSFORMER T3 AND NEW PANEL SHORT CIRCUIT STUDY L1-T3-DP-080 AT NEW UPSTAIRS MEZZANINE WALL. SCALE: N.T.S. GENERAL NOTES: ALL INSTALLATIONS SHALL COMPLY WITH NEC AND ALL APPLICABLE LOCAL CODE AND LOCAL UTILITY REQUIREMENTS. 1 MONTH LOAD HISTORIES SUPPLIED BY MR. DARRYL FOSHEE OF PEC 813-789-6944 AE - 0.i "; 5'PE ::wr• } aLI ■ GE 3 -; �.tfe: %2 ,€ > r 7 ,i)'T ..YrQ.q a'twtj b .tl.tF...�{: .CfY Y 13 f...,�•%,'%v%`, �' ti: - s1143E E, 'OF, ... bj4➢F' Rta!% t,?I,.3b,:3!....... R.?s Ef+i A CKT fKON U3 U.Ra i f)K% d..J. < P $.- I A{ fir %,..a. ,.....� f y y{i 5 ' i'r 9 ���� t /�/ l•y t/��� L. ism ft J'/" Us' NQ� f f 3 Y> N / 4 J tr .„tr',u4 a. ;r, ': c$ 2 �I rL ;'%// / _ .... ✓'r «.......... ai, „ f.. 3 %. " � I f is<. �}3.1!,;Y(3}} 3 '•-ti I 1 � /% / / /� :?i `: f•:✓y� fi i�rr ,n «{. S {lri 4137} t3 Ym )£f:>. 4. ,;.t ll^ `(_{.. / ,s - / / .`is t&,:7 r ,., 3Y.;.x ftx;Y ,R,. 9.5.11-.i.,sE ,rs; <¢ . r ✓ � LA. 16 f / / 4 r. W.• j -.a i, i y • 7Y% a s1 20 r 2f' :. ?P, 'r / •/ �f%� ------------- F;., a- f c;.�ds'..c>'.,,P `4.. k i o f: CONNECrED DEMAND DEMAND LC`..D ✓VA. FAC70R L0AG KVA L.Grf C 1.4 1.25 3 I f; PER NEC ArE c, EQU RF,fE N 4 G $ 4.0 - LARGEST Afi7g; t 125 0Pr R „ 4 3 KVA Epv'a. c _ 0.0 10 .J 2D(,A PS MI,�'� :CrLLANEE.1.5- f:{ 0... $. 00. TOTAL 6.4 68 ';$.i A#l:c'3 CODE "•�w'.rs...s;{:.E :�`ti-:.i o✓G ,:G,.i,_i :REO : £Y re H<"Aw e 3j°S. T xe.,S E C, r,,x a~r;tAsr..,%Y . :Fo3 ESfMN' r'{r 3. aic.s1 Ca ;. g�al ': nr�!PG;; NEC 43 t AC F;J AC �bmuftr sClei NEC AC HT F�)f HNIAC :ire s `Y,. ?Yt r„ taf'i. � 4 'st ali k r,r„<E4?3r's ,Ely ,/ cf O NEW CHEMICAL STORAGE AREA ELECTRICAL DIAGRAM SCALE: N.T.S. RISER DIAGRAM NOTES: 1. EXISTING 12,470 V PROGRESS ENERGY CORP. PRIMARY FEEDER. 2.EXISTING PROGRESS ENERGY CORP (PEC) TRANSFORMER (1000 KVA PAD-MOUNT-26,984 AIC) (T5 PER INFO FROM MR. DALE KIBBY) PEC 12 MONTH LOAD HISTORY SHOWS PEAK OF 677 KW (OR 814 AMPS) ON 7/21/07 FLA FOR 1000 KVA IS 1205 AMPS 3.EXISTING SECONDARY FEEDER- 480/277 VOLT 3 PHASE 4 WIRE 4.EXISTING SWITCHBOARD (INFO FROM DALE KIBBY SHOWS 4000 AMP SWITCHBOARD) 5.EXISTING FEEDER TO EXISTING 480 V DISTRIBUTION PANEL LOCATED IN WAREHOUSE BREEZEWAY 6.EXISTING 480 V PANEL IN WAREHOUSE BREEZEWAY TEXISTING 480 VOLT FEEDER TO EXISTING T1 75 KVA TRANSFORMER IN WAREHOUSE BREEZEWAY &EXISTING 75 KVA DRY TYPE TRANSFORMER 480-120/208 VOLTS LOCATED IN WAREHOUSE BREEZEWAY 9.EXISTING 225 AMP FEEDER 10.PANEL #L1-T1-DP-020 EXISTING 225 A MAIN BREAKER PANEL 120/208 V 3 PH 4 W 11.ADD 1 POLE 20 AMP BREAKERS TO SPACE #1, SPACE #3, AND SPACE #5 AND ADD 1 POLE 30 AMP GFIC BREAKER TO SPACE #14. 12.FEED FOR NEW CHEM STORAGE ROOM LIGHTS-1414 INCH AL CONDUIT WITH 2#10 CU AND 1 #10 CU GRD NOTE: ROUTE CONDUIT WITH EXISTING CONDUIT RUNS IN SAME AREA. 13.FEED FOR VENT FAN TO BE LOCATED ON ROOF FOR NEW CHEM STORAGE ROOM--1-3/4 INCH AL CONDUIT WITH 2410 CU AND 1 #10 CU GRD NOTE: ROUTE CONDUIT WITH EXISTING CONDUIT RUNS IN SAME AREA. 14.FEED FOR CONVENIENCE RECEPTACLES IN CHEM ROOM (3) AND ROOF SERVICE RECEPTACLE GFCIMP (1) AND GFIC RECEPTACLE FOR SINK DRAIN LIFT PUMP (FIELD LOCATE AT SINK) 1-3/4 INCH AL CONDUIT WITH 2#10 CU AND 1#10 GRD 15.FEED FOR TO 30 AMP 1 POLE MOTOR RATED DISCONNECT FOR INSTA-HOT WATER HEATER (3000 WATTS) (FIELD LOCATE AT SINK) 1-3/4 INCH AL CONDUIT WITH 246 CU AND 1410 CU GRD GENERAL NOTES: ALL INSTALLATIONS SHALL COMPLY WITH NEC INCLUDING ALL APPLICABLE NESTLE WATERS CO SPECIFICATIONS AND LOCAL CODES AS WELL AS LOCAL UTILITY REQUIREMENTS. 12 MONTH LOAD HISTORIES SUPPLIED BY MR. DARRYL FOSHEE OF PROGRESS ENERGY CORPORATION 813-789-6944 AFFECTED SERVICES LOAD DATA ____ _....--- ________ _______--------------- _____ ------------------------------- TRAN F MERIPAN LLOCATIONS � ______.__ .- .... .. ...... . ...... . . . ............ ......... ......................................_. .. _------___ .._.___. .. TRANSFCRRMERIPANE" MAXCAPACITY i _QA� HtBT{RYfrom PROGRESS ENERGYR C RDEDL?AaS ........... .... L A}S TO �E ADDED UTILITY TRANSFORMER T1 (2600 KVA) 3fi ? i 19$3; KW,'2169 A'3 on. 9-20-07 541 KW i66 A tapeb V3 i t n•r 5 v 7 i PdtAtN SWITCHBOARD AMPS 30r3(. 424 KW .f� A �4$,.- v brF 9 $� 9 r S Big 3�itt & t t s Eir3LtTYTRANSFORMER75 roti0i#KitAt t re7K,N?81roAtanfy21.07 � Existtng L Pa net 225 t� "v Ktlf (37 A( 205 :f �.. r-'L1 Co t w PF. 't 1 K 54. dtii �a � rt�4$0 yr a 6AKAf(9Addt48f,'V) 6 4 Knf t E f :t7 08 VI .............---,------- ........................_.........,...................................,........................................ .........,...,........................,.......-......---...,-..„.............. «........... ,,„....,,,.......................... .,....................................... CONCLUSIONS: Additions of the new toads are insi riftant at bath Utility Services and to the exisiting Panels and Switchbords where they are being adder!, .... ......... ............. .,..........,......,,...,.., v 0 O Q S CV N N D .iCQ C 4O La r- #k 7 O C Ld 3 o O U 0. W w 0 LL.1 =vs 3 � O N = w- U C O SCE 0 016 o _U vL CC) � r- N oI W co CO CD \ O 00 0M0 ^ OO I-) x I-) � � D-' I � 00 3� z L O Q w m CU a- ^ o �r ,1 _j `Q H z O O W 0 O w O 0 Q F_ z 0 -17 1 w N U Z O d' Lf) wQ �o cno 0 J LL. 0 N j J O J n_ a_ L N O tD 00 N n to to 00Lo 00 00 CD CD rn 00 00 ZEPHYRHILLS 104% a 2924 Date 8-20-08 Sheet E-300 RICHARD P. CHRUSZCZ, P.E. FL.PE LIC. #40080 5