Loading...
HomeMy WebLinkAbout4939 20th Stu I X. ENGINEER'S NOTES: 1. DESIGN WIND SPEED: 140 MPH V 108 2. RISK CATEGORY PER Table 1604.5 II 3. EXPOSURE CATEGORY = "B" MPH V osd 3 sec gust 4. INTERNAL PRESSURE COEFFICIENT = +/— 0.18 5. COMPONENTS &CLADDING DESIGN PRESSURES (ROOF) ONE 1 b: +12/-20 ZONE 2a: +13/-35 ZONE 3a: +13/-52 (WALLS) ZONE4b: +21 /-23 ZONE 5b: +21 /-28 JOB DESCRIPTION: 24'X30' 6 ro 0 6 0 —2 0' 10' 10' (ENCLOSED BLDG) PER ASCE 7-10: COVERED CODES: FLORIDA RESIDENTIAL CODE, FLORIDA BUILDING CODE, 6TH EDITION 2017 ASCE 7-10 CONSTRUCTION TYPE: 5-13 BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE A I 318-11 SPECIFICATIONS FOR STRUCTURAL CONCRETE BUILDING �ACI 301 BUILDING CODE REQUIREMENTS FOR MASONRY STURCTURES (ACT 530-11) NATIONAL DESIGN SPECIFICATIONS FOR WOOD CONSTRUCTION, LATEST EDITION APA PLYWOOD DESIGN SPECIFICATION GENERAL CONTRACTOR AND SUBCONTRACTORS SHALL PERFORM THEIR WORK IN ACCORDANCE WITH ALL APPLICABLE CODES GOVERNING EACH TRADE. CARPORT 'W X 20"H MONOLITHIC CONC FOOTING W/ (2) REBAR CONT ON CHAIRS 48" O.C. MAX COMPACTED _ TERMITE TREATED BOTTOM OF FOOTER SHALL BE 12" BELOW GRADE CONCRETE (3000PS1) WITH #10 -6/10-10 WWM ON 6 MIL POLY �POR BARRIER OVER CLEAN )MPACTED POISON TREATED AL. VAPOR BARRIOR \TERIAL TO BE LAPPED WITH SEAMS TAPED 3ERMESH MAY BE SUBSTITUTED 4X4 PT POST Fu"UAVDATION PLAN 4" CONCRETE (3000PS1) SLAB 16X12 PIER FOOTER WITH (4) #5 =co REBAR REINF. MAT (TYPICAL) 1' '---------------- -I---------------- 1'-4" — 4„ _ 20' 12"W X 20"H MONOLITHIC CONC FOOTING W/ (2) PL REBAR CONT ON CHAIRS 48"O.C. MAX COMPACTED TERMITE TREATED BOTTOM OF FOOTER SHALL BE 12 BELOW GRADE a SLOPE SIDE ELEVA TI01\1 hereby certify that I have reviewed this plan and found it to be in compliance with ASCE 7-10 and the Florida Building Code 2017 6th Edition David W. Smith, P.E. #53608 TO'0111111111H I ®o: s A. was 0 mom g ATE ®F n 20' 10' 10' 0 F-1 L. J O F L J O FLU"ORA PLAI\\[ ELEVATION ALL WORK H ALL, ,-;QFA")LY }ab' TH PREVAILING CODES rLOR10A BUILDING CODE, NATIONAL EL ttT0IC CODE, AND_THE C! F-PHYRHILLS PARCEL: 14- 26- 21- 0010- 00100- 0030 00 BRIDGES CHR STOPHER 8c CR ST NA 4939 20TH STREET ZEPHYRH LLS, FLORIDA D.W. SMITH M.S.,P.E.#53603 FLORIDA PROFESSIONAL ENGINEER LICENSE NUMBER 53608 PROJECTS ENGINEERING CONSULTANT 9909 WALLASTON DRIVE—DADE CITY, FLORIDA 33525 PHONE: 813-469-2Z89 E-MAIL: dwsf 1p0earth l l nk, net DEC 2019 k Vt,,W �T PLAN EXAMINER RICK GOLLIIARDT - DRAFTSMAN 813- 781- 3651 Tgollhardt@tampabay.rr.com FLOOR PLAN SCALE DO NOT SCALE DESIGN/DRAWN R. GOLLHARDT DATE 15 JUL 2019 CHECKED D.W.S. SHEET OF 2 JOD NO L ENGINEER LICENCE #53608 2019-0613 M FASTEN 2X8 PT ROOF RAFTER TO DOUBLE 2X8 PT WOOD BEAM WITH SIMPSON SDWS WOOD SCREWS 1 /4"X6" (3) MIN PER CONNECTIONS TYPICAL EACH ENb FASTEN 4X4 PT POST TO DOUBLE 2X8 PT WO D BEAM WITH SIMPSON LCE4 RATED \ 1905 UPLIFT ATTACH PER MANUF. SPECS TYPI AL BOTH SIDES OF POST FL 10860 r,. 4X4 PT POST rA C -rr—K I MID 4X4 PT POST TO DOUBLE 2X8 BEAM WITH SIMPSON LPCZ RATED PLIFT ATTACH PER MANUF. SPECS BOTH SIDES OF POST FL 10860 DOUBLE 2X8 PT WOOD BEAM .4" KNEE BRACE FASTEN TO 4 4 PT POST 'ITH SIMPSON LSC RATED 755 UPLIFT 7ACH PER MANUFACTURERS ECS FL 10865 "-4X4 PT POST 24" KNEE BRACE FASTEN TO 4X4 PT POST ENLA RGED CIRCLE B � 9 WITH SIMPSON LSC RATED 755# UPLIFT ATTACH PER MANUFACTURERS SPECS FL 1086 ENLARGED CIRCLE "A" FASTEN 4X4 PT POST TO CONCR TE SLAB WITH SIMPSON PS44 RATED 1485# UPLIFT 4X4 PT POST ATTACHPER MANUF. SPECS —�' � � TYPICAL ALL POST FL 10860 ENLARGED CIRCLE "C" 2X8 ROOF RAFTERS SPACED 24" O.C. r A r'T F_ N I r-) \/ C] F)T TPO ROOFING MEMBRANE APPLYED PER MANUFACTURERS SPEC SHEATHING TO BE 15/32" 4 PLY CDX OR OSB W/8d RING SHANK NAILS 6" O.C. 4" O.C. DOUBLE 2X8 PT EDGE BEAM W 1 2" PLYWOOD SPLICE G LI D AND NAILED 48"MINIMUM OVERLAP SPLICE 4X4 PT POST TYPICAL 10' 'GOOF IS28 30TH RAFTER TO DOUBLE PT EGDE BEAM RATED 1165# ATTACH PER MANUF. ENDS. FL 10655 (2) 16d DEADWOOD MONONAILSYE��H SHEATHING C FASTEN MID 4X4 PT POST TO DOUBLE 2X8 PT WQOD BEAM WITH SIMPSON LPCZ RATED 1905 p UPLIFT ATTACH PER MANUF. SPECS TYPI AL BOTH SIDES OF POST FL 10860 ------------------ 10' 30' SLOPE 10' =//'rnr� -PO ROOFING MEMBRANE APPLYED PER MANUFACTURERS SPEC ;HEATHING TO BE 15/32" 4 PLY CDX OR OSB W/8d RING SHANK NAILS 3" O.C. 4" O.C. FASTEN 4X4 PT POST TO DOUBLE 2X8 PT WO D BEAM WITH SIMPSON LCE4 RATED 905 UPLIFT ATTACH PER MANUF. SPECS YPI AL BOTH SIDES OF POST FL 1086 -FASTEN MID 4X4 PT POST TO DOUBLE 2X8 PT W,QOD BEAM WITH SIMPSON LPCZ RATED 1905 q� UPLIFT ATTACH PER MANUF. SPECS TYPICAL BOTH SIDES OF POST FL 10860 co 4X4 PT POST TYPICAL 20' F-R.01VT E71 ]��,_'V A T 10" N DOUBLE 2X8 PT BOARD WITH 112" PLYWOOD SPLICE NAILED AND GLUED. MIN OVERLAP 48" NAIL WITH 8d COMMON NAILS SPACES 12" STAGGERED 4' ' 12' 12' 30' ROM hereby certify that I have reviewed this plan and found it to be in compliance with ASCE 7-10 and the Florida Building Code 2017 6th Edition David W. Smith, P.E. #53608 ENGINEER LICENCE #53608 IN. vULLI-1ANU I I U.VV.�. 4 FL # Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence FL10124-R20 Revision 2017 Approved GAF 1 Campus Drive Parisppany, NJ 07054 (800) 766-3411 mstieh@gaf.com Robert Nieminen lindareith@trinityerd.com William Broussard 1 Campus Drive Parsippany, NJ 07054 (800) 766-3411 TechnicalQuestionsGAF@gaf.com Roof i ng Asphalt Shingles Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Robert Nieminen PE-59166 UL LLC 10/20/2018 John W. Knezevich, PE ` Validation Checklist - Hardcopy Received FL10124 R20 COI 2017 01 COI Nieminen.pdf Referenced Standard and, Year (of Standard) standard Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved ASTM D1970 ASTM D3161 ASTM D3462 ASTM D7158 TAS 107 Method 1 Option D 09/20/2017 09/27/2017 09/28/2017 12/12/2017 Year 2015 2016 2010 2011 1995 TRINITY ERD 4.3 Accessory Starter Strips: 4.3-1 Pro -Start® Eave/Rake Starter Strip Shingles and WeatherBlocker- Premium Eave/Rake Starter Strip Shingles are starter strips for asphalt roof shingles. 4.3.2 QuickStart® Peel & Stick Starter Roll is a is a mineral -surfaced, fiberglass -reinforced, self -adhering SBS modified bitumen starter strip, nominal 9-inch x 33 ft roll, for use with asphalt shingles with exposure of 6- inch or less. 4.3.3 StarterMatch„„ Sharter Strip Shingles are color -coordinated starter strips for use with Grand Canyon® and Grand Sequoia® series asphalt shingles. StarterMatch'"' are installed as the second starter for Grand Canyon® and Grand Sequoia® series installations. S. LtMITATIONS- 5.1 This is a building code evaluation. Neither TrinitylERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in the HVHZ. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. SA Wind Classification: 5.4.1 The GAF asphalt shingles noted in Section 4.1 are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating the shingles are acceptable for use in all wind zones up to Vasd = 150 mph (V it = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.2 The GAF hip & ridge shingles noted in Section 4.2 are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the shingles are acceptable for use in all wind zones up to Vasd = 150 mph (V,,,t = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.3 Classification by ASTM D7158 applies only to exposure category B or C, as defined in FBC 1609.4.3, and a mean roof height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.5 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building Code and F.A.C. Rule 61G20-3. 6. INSTALLATION: 5.1 Underlayment: 6.1.1 Underlayment shall be acceptable to GAF and shall hold current Florida Statewide Product Approval, or be Locally Approved per Rule 61G20-3, per FBC Sections 1507.2.3, 1507.2.4 or R905.2.3. 6.2 Starter Shingles or Starter Strip: 6.2.1 Installation of Pro -Start Eave/Rake Starter Strip Shingles, WeatherBlocker Premium Eave/Rake Starter Strip Shingles and QuickStart Peel & Stick Starter Roll shall comply with the GAF current published instructions. 6.3 Asphalt Shingles: 6.3.1 Installation of asphalt shingles shalt comply with the manufacturer's current published instructions, using minimum four (4) nails per shingle in accordance with FBC Sections 1507.2 or R905.2, with the following exceptions: r Camelot, Camelot II, Grand Canyon, Grand Sequoia, Grand Sequoia IR, Grand Sequoia ArmorShield, and Woodland require minimum five (5) nails per shingle. Y Slateline requires minimum six (6) nails per shingle. Exterior Research and Design, I.I.C. Certificate of Authorization #9503 Evaluation Report 01506.01.08-R21 FL10124-8i9 Revision 21: 08/2612016 Page 4 of 6 TRINITY ERD EVALUATION REPORT EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization #9503 353 CHRISTIAN STREET, UNIT 413 OXFORD, CT 06478 PHONE: (203) 262-9245 FAX: (203) 262-9243 GAF Evaluation Report 01506,01.08-R21 1 Campus Drive FL10124-R19 Parsippany, NJ 070S4 )late of Issuance: 0I/03/200$ SCOPE: Revision 21: 08/26/2016 This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P-E. for use of the product Lender the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the Sth Edition (2014) Florida Building Code sections noted herein. DESCRIPTION: GAF Asphalt Roof Shingles LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinitylERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity] ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building official. This Evaluation Report consists of pages 1 through 6. Prepared by: Robert J.M. Nieminen, P.E. y,,�S "-•• "`p?•s•` Themflesea) appearing was authorizedbyRobentheminen, =' _� <<� P.E. on 08/26/2016. This does not serve as an electronically signed Florida Registration No. 59166, Florida DCA ANE1983 document. Signed, sea,ed hardcoples have been transmit ed to the CERTIFICATION OF INDEPENDENCE: Product Approval Administrator and to the named Gent 1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinityl ERD is not owned, operated or controlled by any company manufacturing ordistributing products it evaluates. 3- Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued, 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. S. This is a building code evaluation. Neither TrinitylERD nor Robert Nieminen, P-E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. TRINITY ERD 6.3.2 Fasteners shall be in accordance with manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.3.3 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required. Contact the shingle manufacturer for details. 6.4 Hip & Ridge Shingles: 6.4.1 Installation of Sea( -A -Ridge Ridge Cap Shingles, Seal -A -Ridge IR Impact -Resistant Ridge Cap Shingles and Seal - A -Ridge ArmorShield Ridge Cap Shingles shall comply with the manufacturer's current published instructions with a minimum two (2) nails, minimum 3/8-inch head diameter, per shingle and nominal 0.25-inch diameter beads of Henkel "Loctite PL 530 Roof & Flashing Sealant". 11.5' Sealant 1' (292 mm) 1" Sellanie (2o mm) (25 mm) Enduft d'etanch&6 i fl ( NI ! (305 mm) Ciavo 6518'-75,8' (3louer (168 - 194 mm) - 12" f305 Mal) 6A.2 Installation of Timbertex Premium Ridge Cap Shingles shall comply with the manufacturer's current published instructions with a minimum two (2) nails, minimum 3/8-inch head diameter, per shingle and beads of Sonneborn NPI Gun Grade Polyurethane Sealant or Henkel PL Roofing and Flashing Sealant. J* !2 211 :YipY. ;F 6A.3 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. Exterior Research and Design, LLC. Evaluation Report 01506.01.08-R21 Certificate of Authorizatian 0503 FL10124-R19 Revision 21: 08/26/2016 Page 5 of 6 TRINITY ERD ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Asphalt Shingles - Compliance Statement: GAF Asphalt Roof Shingles, as produced by GAF, have demonstrated compliance with the following sections of the Florida Binding Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.2.4, R905.23 Physical Properties ASTM D1970 2009 1507.2.5, R905.2.4 Physical Properties ASTM D3462 2009 1507.2.7.1, R905.2-6.1 Wind Resistance ASTM D3161 2009 1507.2.7A, R905.2.6.1 Wind Resistance ASTM D7158 2008 1507.2.7-1, R905.2.6-1 Wind Resistance TAS 107 1995 3. REFERENCES: gn!!bt Examination Reference Crate GAF (PDM 1915) Letter of Equivalency Seal -A -Ridge Impact Resistant IR 01/13/2012 PRI (TST 5878) Physical Properties GAF-025-02-01 03/27/2002 PRI (TST 5878) ASTM D3462 GAF-059-02-01 09/02/(2004 PRI (TST 5878) ASTM D3462 GAF-080-02-01 OS/25/2005 PRI (TST 5878) Physical Properties GAF-324-02-01 12/01/2011 PRI (TST 5878) Wind Driven Rain GAF-407-02-01 01/21/2013 UL(TST 1740) ASTM D3462 93NK629S 11/29/1993 UL (TST 17401 ASTM D3462 99NK43835 01/12/2000 UL (TST 1740) TAS 107 94NK9632 03/29/2000 UL(TST 1740) ASTM D3462 OINK06632 02/02/2001 UL (TST 1740) ASTM D3161, TAS 107 01NK9226 05/21/2001 UL (TST 1740) ASTM D3161 OINK37122 12/18/2001 UL (TST 1740) ASTM D3462 OINK37122 12/19/2001 UL (TST 1740) ASTM D3161, TAS 107 02NK12980 04/10/2002 UL (TST 1740) ASTM D3161, TAS 107 02 NK30871 09/09/2002 UL (TST 1740) ASTM D3161 03CAS367 03/11/2003 UL(TST 1740) ASTM D3462 03NK26444 10/17/2003 UL (TST 1740) ASTM D3462 04NK13850 06/07/2004 UL (TST 1740) ASTM D3161 04NK13850 06/23/2004 UL(TST 1740) ASTM D3161 04NK30546 03/10/2005 UL(TST 1740) ASTM D3462 04NK22009 05/06/2005 UL (TST 1740) ASTM D3161 04NK22009 05/09/2005 UL (TST 1740) ASTM D3462 05NK27924 02/10/2006 UL (TST 1740) ASTM D3161 OSNK27924 02/11/20015 UL (TST 1740) ASTM D3161, D3462 OGCA18077 06/05/2006 UL (TST 1740) ASTM D3161, D3462 06CA18074 06/16/2006 UL (TST 1740) ASTM D3161, D3462 06CA35251 10/18/2006 UL (TST 1740) ASTM D3462 06CA31603 12/01/2006 UL (TST 1740) ASTM D3161, D3462 06CA41095 12/27/2006 UL (TST 1740) ASTM D3161 07NKG5228 03/13/2007 UL (TST 1740) ASTM D3161 06CA31611 04/04/2007 UL(TST 1740) ASTM D3161 06CA61148 04/09/2007 UL (TST 1740) ASTM D3161, 03462 07CA31742 11/08/2007 UL (TST 1740) ASTM D3151, D7158, D3462 OBCA06100 03/13/2008 UL (TST 1740) ASTM D3161, D3462 07CA55908 04/01/2008 Exterior Research and Design, LLC. Evaluation Report 01506,01,08-R21 Certificate of Authorization #9503 FL10124-R19 Revision 21: 08/26/2016 Page 2 of 6 TRINITY ERD 7. LABELING: 7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2.7.1 / R905-2.6.1. 8. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the named QA entity for information on which plants produce products covered by Florida Rule 61G20-3 CIA requirements. 10. QUALITY ASSURANCE ENTITY: UL LLC —QUA9625; (847) 664-3281 Exterior Research and Design, LLC. Certificate of Authorization #9503 - END OF EVALUATION REPORT - Evaluation Report 01506.01.08-1121 F1.10124-1119 Revision 21: 08/26/2016 Page 6 of 6 TRINITY ERD Entity Examination Reference Date UL (TST 1740) ASTM D3161, D3462 09CA10592 03/26/2009 UL(TST 1740) ASTM D3161,D3462 09CA06856 05/15/2009 UL (TST 1740) ASTM D3161, D7158, D3462 09NK06647 08/01/2009 UL (TST 1740) ASTM D3161, D7158, D3462 09CA27281 08/27/2009 UL (TST 1740) ASTM D3161, D7158, D3462 1OCA35554 03/05/2010 U L (TST 1740) ASTM D3161, D7158, D3462 IOCA13686 05/15/2010 UL (TST 17401 ASTM D3462 10CA07264 05/27/2010 UL (TST 1740) ASTM D3462 IOCA12953 10/79/2010 UL (TST 1740) ASTM D3161,D7158, D3462 IONK11951 10/30/2010 UL (TST 1740) ASTM 03161,D7158, D3462 1UNK12070 11/04/2010 UL (TST 1740) ASTM D3161,D7158, D3462 08CA06100 01/30/2010 UL (TST 1740) ASTM D3161, D7158, D3462 IOCA53934 03/31/2011 UL (TST 1740) ASTM D3161, WIS8, D3462 11CA48924 10/22/2011 UL (TST 1740) ASTM D3161, D7158, D3462 11CA47919 12/03/2011 UL (TST 1740) ASTM D3161, D7158, D346Z IICA48408 12/08/2011 UL (TST 1740) ASTM D3161, D7158, D3462 11CA48725 12/09/2011 UL, LLC. (TST9628) ASTM D3462 12CA34891 10/12/2012 UL, U.C. (TST 9628) ASTM D3161, D7158, 03462 12CA58151 02/15/2013 UL, LLC. (TST 9628) ASTM D3161 12CA38083 02/26/2013 UL, U.C. (TST 9628) ASTM D3161 13CA32332 06/18/2013 UL, LLC (TST 9628) ASTM D3161 13CA37934 08/02/2013 UL, LLC. (TST 9628) ASTM D3161, D7158, D3462 4786875675 07/17/2015 UL, LLC. (TST 9628) ASTM D3161, D7158, D3462 4787434542 05/17/2016 UL, LLC. (QUA 9625) Quality Control inspection Report, R21, Mobile, AL 12/28/201S UL, LLC. (QUA 9625) Quality Control Inspection Report, R21, Myerstown, PA D2/23/2016 UL, LLC. (QUA 9625) Quality Control inspection Report, R21, Tuscaloosa, AL 02/26/2016 UL, LLC. (QUA 9625) Quality Control Inspection Report, R21, Michigan Cry, IN 03/02/2016 UL, LLC (QUA9625) Quality Control Inspection Report, R21, Shafter, CA 02/18/2016 UL, LLC. (QUA 9625) Quality Control Inspection Report, R21, Savannah, GA 02/24/2016 UL, LLC, (QUA 9625) Quality Control Inspection Report, R21, Minneapolis, MN 02/09/2016 UL, LLC. (QUA 9625) Quality control Inspection Report, R21, Mt. Vernon, IN 02/09/2016 UL, LLC. (QUA 9625) Quality Control Inspection Report, R21, Baltimore, MD D3/01/2016 UL, LLC (QUA 9625) Quality Control Inspection Report, R21, Tampa, FL 02/29/2016 UL, LLC. (QUA 9625) Quality Control Inspection Report, R21, Dallas, TX 02/17/2016 UL, LLC. (QUA962S) Quality Control Inspection Report, R21, Ennis, TX 02/03/2016 UL, LLC (QUA 9625) Quality Control Inspection Report, R21, Fontana, CA 03/03/2016 4. PRODUCT DESCRIPTION: 4.1 Asphalt Shingles: 4A.1 Marquis" WeatherMaxe, Royal Sovereign® and Sentinel° are a fiberglass reinforced 3-tab asphalt roof shingles. 4.1.2 Camelot®, Camelot" II, Fortitude", Glenwood'", Grand Canyon®, Grand Sequoia", Grand Sequoia° IR, Grand Sequoia" ArmorShield'", Monaco', Sienna", Timberline® American Harvest', Timberline® ArmorShield'" 11, Timberline® Natural Shadow®, Timberline HD®, Timberline' Cool Series®, Timberline Ultra HD® and Woodland® are fiberglass reinforced, laminated asphalt roof shingles. 4.13 Slateline° is a fiberglass reinforced 5-tab asphalt roof shingle. 4.2 Hip & Ridge shingles: 4.2.1 Seal -A -Ridge® Ridge Cap Shingles, Seal -A -Ridge° IR Impact -Resistant Ridge Cap Shingles, Seal -A -Ridge® ArmorShield»" Ridge Cap Shingles and Timbertexa Premium Ridge Cap Shingles are fiberglass reinforced, hip and ridge asphalt roof shingles. Exterior Research and Design, LLC. Certifuate of Authorization #9503 Evaluation Report 01506.01.08-R21 FL10124-R19 Revision 21: 08/26/2016 Page 3 of 6 METAL DRIP EDGE AT RAKE APPLIED OVER UNDERLAYMENT IN ASPHALT FELT RDILF SHEATHING NAIL DVTIMM UNDERLAYMENT _ _ 6d NAD-S SHANK) 6' O,C. RW *F T!`M NAIL 2 EDGES 6d NAILS CRINGSFYWO 4' O,C. METAL DRIP APPLIED OVER SHEATHING USE ONLY ENOUGH NAILS TO HOLD UNDERLAYMENT IN PLACE UNTIL SHINGLES ARE LAID ROOF UNDERLAYMENT APPLICATI❑N TYPICAL FOR GAF/LANDMARK SIMIGLES ETC. 1. ROOF COVERINGS SHALL BE APPLIED IN ACCORDANCE WITH THE APPLICABLE PROVISIONS OF SECTION 1507. FBC, 2010 2. FOR R®F SLOPES 2!12 UP TO 4!12 UNDERLAYMENT SHALL BE A MINIMUM OF 2 LAYERS APPLIED AS FOLLOWS, (SEE ABOVE) FBC 1507.3.8.1 3. FOR ROOF SLOPES 442 OR GREATER UNDERLAYMENT SHALL BE A MINIMUM OF ONE LAYER OF UNDERLAYMENT FELT APPLIED AS FOLLOWS, STARTING AT THE EAVE UNDERLAYMENT SHALL BE APPLIED SHINGLE FASHION PARALLEL TO THE EAVE, LAPPED 2' AND FASTENED SUFFICIENTLY TO STAY IN PLACE UNTIL SHINGLES ARE LAID. FBC 1507.3.8.2 4. DRIP EDGE, ➢RIP EDGE SHALL BE PROVIDE➢ AT EAVES AND GABLES OF SHINGLE ROOFS AND OVERLAPPED A MINIMUM OF 2 INCHES EAVE DRIP EDGES SHALL EXTEND 1/4' BELOW SHEATHING AND EXTEND BACK ON THE ROOF A MINIMUM OF 2 INCHES. DRIP EDGE SHALL BE MECHANICALLY FASTENED A MAXIMUM OF 12' ON CENTER. FBC 1507.3.8.3 9' STARTER STRIP OR COURSE OF INVERTED SHDJGLES 150 ASPHALT FELT UNDERLAYMENT �a..35 STEEL PLYCL 8d IRS NA PLYWOOD NAIL PATTERN (ROOF) 15/32' CDX SHEATHING SHALL BE NAILED W/ 8d IRS NAILS @ 6' ❑,C, @ EDGES AND 8' ❑,C, MAX, IN THE FIELD, USE 1/2' STEEL PLYCLIPS, METAL DRIP EDGE AT RAKE APPLIED OVER UNDERLAYMENT START TMORD COARSE WITH FILL STRIP HINDS FIRST TAB — START SECOND COURSE WITH FULL STRIP MINUS 1/2 TAB START FIRST COURSE WITH FULL STRIP R❑❑FING APPLICATI❑N 1. ROOF COVERINGS SHALL BE APPLIED IN ACCORDANCE WITH THE APPLICABLE PROVISIONS OF SECTION 1507 FBC AND THE MANUFACTURERS INSTALLATION INSTRUCTIONS. 2. ASPHALT SHINGLES SHALL BE USED ONLY ON ROOF SLOPES OF 2,12 OR GREATER, FOR ROOF SLOPES FROM 2,12 UP TO 4,12 DOUBLE UNDERLAYMENT APPLICATION IS REQUIRED. 3, UNLESS OTHERWISE NOTED, REQUIRED UNDERLAYMENT SHALL CONFORM WITH ASTM D 226, TYPE 1, OR ASTM 4869, TYPE I FBC 1507.3.3 4, SELF ADHERING BITUMEN SHEET SHALL COMPLY WITH ASTM D225 OR ASTM D3462, FBC 1507.3.4 5, ASPHALT SHINGLES SHALL HAVE SELF SEAL STRIPS OR BE INTERLOCKING, AND COMPLY WITH ASTM D225 OR ASTM 13462, FBC 1507.3.5 6. FASTENERS FOR ASPHALT SHINGLES SHALL BE GALVANIZED, STAINLESS STEEL, ALUMINUM, OR COPPER ROOFING NAILS MINIMUM 12 GA (0,105 INCH SHANK WITH A MINIMUM 3/8- DIAMETER HEAD, OF A LENGTH TO PENETRATE THROUGH THE ROOFING MATERIALS AND A MINIMUM OF 3/4' (19101101) INTO THE ROOF SHEATHING. WHERE THE ROOF SHEATHING IS LESS THAN 3/4' THICK THE NAILS SHALL PENETRATE THROUGH THE SHEATHING. FBC 1507.3.6 7. ASPHALT SHINGLES SHALL BE SECURED TO THE ROOF WITH NOT LESS FOUR FASTENERS PER STRIP OR TWO FASTENERS PER INDIVIDUAL SHINGLE. UNLESS OTHERWISE NOTED ATTACHMENT OF ASPHALT SHINGLES SHALL CONFORM WITH ASTM D3161 (MODIFIED TO 110 MPH) OR M-DC PA 107-95. FBC 15073,7