HomeMy WebLinkAbout5053 Gall Blvd5�2,�F2r� �002
Product Approval
USER: Public User
Product Approval Menu > Product or Application
Search > Application List > Application Detail
FL #
FL8791
Application Type
New
_ Code Version
2004
Application Status
Approved
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Certification Agency
Validated By
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Arch Aluminum and Glass Co., Inc.
10200 NW 67th Street
Tamarac, FL 33321
(800)432-8132 Ext198
fdeato@archaluminum.net
Bong Deato
fdeato@archaluminum.net
FROILAN BONG DEATO
10200 NW 67TH ST
TAMARAC, FL 33321
(800)432-8132 Ext198
fdeato@archaluminum.net
Exterior Doors
Swinging Exterior Door Assemblies
Certification Mark or Listing
Miami -Dade BCCO - CER
Standard
FBC 2411 3.2.1 / TAS 202-94 Force Entry
TAS 202 Air Infiltration/Uniform Static Air
Product Approval Method Method 1 Option A
Date Submitted 04/25/2007
Year
2004
2004
R
GENERAL NOTES:
PLAN NOTES;
(Q
HAZARDOUS L❑CATIONS
d
1, WIND DESIGN SPEED = 110 MPH (3 sec gust)
2, WIND IMPORTANCE FACTOR = 1,15 FOR ENCLOSED STRUCTURE
GROUP "B"
3. WIND EXPOSURE CATEGORY= "B"
4, INTERNAL PRESSURE C❑EFFICIENT = +18/-18 (ENCLOSED BLDG)
APPLICABLE CODES
THE FOLLOWING CODES WILL APPLY TO CONSTRUCTION
2007 FLORIDA BUILDING CODE w/2009 SUPPLEMENTS
2007 FLORIDA BUILDING CODE., PLUMBING w/2009 SUPPLEMENTS
2007 FLORIDA BUILDING CODE, MECHANICAL w/2009 SUPPLEMENTS
2007 FLORIDA BUILDING CODE,, FUEL GAS w/2009 SUPPLEMENTS
2007
FLORIDA
ENERGY EFFICIENCY CODE FOR
BUILDING
C❑NSTRUCTI❑N
2007
FLORIDA
ACCESSIBILITY CODE
BUILDING
CONSTRUCTION
2009
NATIONAL
ELECTRICAL CODE
2009
NFPA 101
LIFR SAFETY CODE
2007
FLORIDA
FIRE PREVENTION CODE
DESIGN CRITERIA;
ALLOWABLE SOIL BEARING=2000psf (VERIFY BY SOILS TESTING COMPANY)
CONCRETE FOR FOOTINGS, BOND BEAMS, FILLED CELLS AND CAST -IN -PLACE
COLUMNS SHALL HAVE MIN. C❑MPRESSIVE STRENGTH OF 3000 psi @ 28 DAYS.
CONCRETE FOR WALKS AND SLAB ON GRADE SHALL HAVE A MIN. C❑MPRESSIVE
STRENGTH OF 3000 psi @ 28 DAYS (CHECK LOCAL CODES ON PSI)
CONCRETE BLOCK Fm=2000psi (TYPE I)
MORTAR ASTM C270 Ft= 2000psl (TYPE S)
REINFORCING STEEL SHALL COMPLY WITH ASTM "A615
GRADE 40 (Fy=40,000psi)
ANCHOR BOLTS SHALL COMPLY WITH ASTM A36 STEEL
FOOTING SHALL BE PLACED IN UNDISTURBED SOIL OR CLEAN, WELL GRADED BACKFILL
MATERIAL, FIRMLY MAX DRY DENSITY COMPACTED TO 95%
DESIGN SHALL COMPLY WITH THE STANDARD FOR HURRICANE RESISTANT
RESIDENTIAL CONSTRUCTION (SSTD 10-99)
INTERIOR REQUIREMENTS
FLAME SPREAD/SMOKE DEV.-EXIT ACCESS UNSPRK+ TYPE 'B' FLAMESPREAD 26-75 SMOKE DEV, 0-450
FLAME SPREAD/SMOKE DEV.-EXIT ACCESS SPRK, TYPE 'C' FLAMESPREAD 76-200 SMOKE DEV, 0-450
FLAME SPREAD/SMOKE DEV.-OTHER SPACES UNSPRKI TYPE 'C' FLAMESPREAD 76-200 SMOKE DEV. 0-450
FLAME SPREAD/SMOKE DEV.-OTHER SPACES SPRKI TYPE 'C' FLAMESPREAD 76-200 SMOKE DEV. 0-450
THE CLIENT UNDERSTANDS THAT THE DESIGNER CARRIES NO LIABILITY INSURANCE AND
THEREFORE AGREES TO HOLD HARMLESS, MEMNITY, AND DEFEND DESIGNER FROM ALL
CLAIMS, LOSSES AND EXPENSES (INCLUDING REASONABLE ATTORNEY FEES) ARISING OUT
OF OR RESULTING FROM THE PROJECT. THE DESIGNER WILL IN GOOD FAITH ATTEMPT TO
PROVIDE ERROR FREE CONSTRUCTION DRAWINGS, BUT IN THE EVENT ERRORS OCCUR THE
DESIGNDER WILL NOT BE LIABLE FOR COST OF REPAIRS OR DELAY TO THE CONSTRUCTION.
6
1. ALL WORK SHALL BE EXECUTED IN ACCORDANCE WITH THE 2007 FLA. BLDG.
CODE, 2009 SUPPLEMENTS AND SHALL FOLLOW ALL LOCAL CODES,RULES,
REGULATIONS, AND ❑RDIANCES.
2. ALL WORK SHALL BE COMPLETED IN A NEAT AND CRAFTSMANLIKE MANNER
AND UPON COMPETITION SHALL BE INSPECTED BY THE GENERAL
REGULATIONS, AND ❑RDIANCES.
3. CONTRACTOR SHALL COMPLY WITH ALL OSHA REQUIREMENTS.
4. CONTRACTOR SHALL ARRANGE FOR AND PAY FOR ALL REQUIRED PERMITS.
5. ALL SUB -CONTRACTORS SHALL BE RESPONSIBLE FOR THE DISPOSAL OF
THEIR RELATED REFUSE.
6. ALL CONDITIONS, DRAWINGS, DIMENSIONS, ETC, SHALL BE FIRST VERIFIED BY
THE GENERAL BLDG, CONTRACTOR AND SUB -CONTRACTORS PRIOR TO THE
ORDERING OF MATERIALS AND CONSTRUCTION FOR DELETIONS, ERRORS,
AND/OR ❑MISSIONS. FAILURE TO NOTIFY THL ENGINEER SHALL RELIEVE THE
ENGINEER FROM RESPONSIBILITY AND ANY CORRECTIVE COSTS,
7. ANY ALTERATIONS OR DEVIATION FROM THESE DRAWINGS SHALL BE MADE
WITH THE COMBINED APPROVAL OF THE OWNER AND THE ENGINEER. ITEMS
NOT APPROVED SHALL RELIEF THE OWNER AND THE ENGINEER OF
RESPONSIBILITY AND ANY COSTS TO CORRECT THE ALTERATION OR
DEVIATION.
8. CONTRACTOR SHALL PROVIDE ALL NECESSARY AND REQUIRED BLOCKING,
BRACING AND SECURING OF ALL MATERIAL AND EQUIPMENT AS REQUIRED.
9, ALL WOOD SPECIFIED SHALL BE PINE, FIR OR SPRUCE NO. 2 GRADE OR
BETTER AND PRESSURE TREATED WHERE REQUIRED.
10. ALL PREFABRICATED BRACKETS AND CONNECTORS TO BE INSTALLED IN
ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS.
11. ALL WINDOWS AND DOORS TO BE INSTALLED PER MFR. INSTRUCTIONS/
SPECIFICATION AND MUST BE RATED TO SATISFY SPECIFIED WIND PRESSURES,
12. THE ENGINEER IS NOT RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS,
OR SCHEDULE.
13. WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALED DIMENSIONS.
LARGE SCALE DETAILS SHALL TAKE PRECEDENCE OVER SMALLER SCALE
DRAWINGS.
14. CONTRACTOR SHALL OBTAIN A CERTIFICATE OF OCCUPANCY FROM THE
AUTHORITY HAVING JURISDICTION UPON COMPLETION OF THIS WORK,
15. CONTRACTOR SHALL GUARANTEE ALL WORK FOR A MINIMUM OF ONE YEAR
AFTER COMPLETION OF WORK.
CODE REQUIREMANTS
FLORIDA BUILDING CODE
2007 ED, w/2009 SUPPLEMENTS
OCCUPANCY
GROUP "B" BUSINESS
SPECIAL OCCUPANCY
STORAGE SEPARATION (1) HOUR
REQUIREMENTS
CONSTRUCTION TYPE
TYPE II, UNPROTECTED
ALLOWABLE AREA
AREA; 2880 SF
& HEIGHT
HEIGHT; <20'
FIRE RESISTANCE -
C❑RRI (1) HOUR
SEPARATION p,
CORRI B-CLG, (1) HOUR
FIRE ALARM SYSTEM
MANUA ULL STATIONS @
EXIT D MOKE DECTECTORS
IN SUP D RETURN AIR DUCTS,ST❑RAG NNS
MS, RESTRO❑MS
EMERGENCY LIGHTING
BATTERY POWERED EMERGENCY
LIGHTING W/INTEGRAL CHARGER
IN ALL OCCUPIED AREA'S
EXIT LIGHTS
BATTERY POWERED EXIT
LIGHTING W/INTEGRAL CHARGER
& TEST LIGHT
FIRE SUPPRESSION
PORTABLE FIRE EXTINGUISHERS
KIDDE
MIN. NUMBER OF EXITS
(2) REQUIRED
(2) PROVIDED
MAXIMUM TRAVEL
75' W/ A 20 FT MAXIMUM
DISTANCE
DEAD END
MIN. CEIRRI-DOR
44"
MIN CLEAR OPENING
32"
OF EXIT DOORS (IN);
1. A FOUNDATION SURVEY SHALL BE PERFORMED AND A COPY OF THE SURVEY SHALL BE
ON THE SITE FOR THE BUILDING INSPECTORS USE. OR, ALL PROPERTY MARKERS SHALL BE
EXPOSED AND A STRING STRETCHED FROM MARKER TO MARKER TO VERIFY REQUIRED SETBACKS,
2. ALL PLUMBING, ELECTRICAL, MECHANICAL ROUGH -INS MUST BE COMPLETE,
INSPECTED, AND APPROVED BEFORE REQUESTING THE FRAMING INSPECTION.
3. A PERMANENT SIGN WHICH IDENTIFIES THE TERMITE TREATMENT PROVIDER AND
NEED FOR RE -INSPECTION AND TREATMENT CONTRACT RENEWAL SHALL BE PROVIDED.
THE SIGN SHALL BE POSTED NEAR THE WATER HEATER OR ELECTRICAL PANEL. FBC 104.2.6
4. CONDENSE AND ROOF DOWN SPOUTS SHALL DISCHARGE AT LEAST 1'-0' AWAY FROM
BUILDING SIDE WALLS, FBC 1503.4.4
5. IRRIGATION/SPRINKLER SYSTEMS INCLUDING RISERS AND SPRAY HEADS SHALL NOT
BE INSTALLED WITHIN 1'-0" OF THE BUILDING SIDE WALL. FBC 1503.4.4
6. TO PROVIDE FOR INSPECTIONS FOR TERMITE FOR INFESTATION, BETWEEN WALL COVERING
AND FINAL EARTH SHALL NOT BE LESS THAN 6 INCHES.
7. INITIAL TREATMENT SHALL BE DONE AFTER ALL EXCAVATION AND BACKFILL IS COMPLETE
FBC 1816.1.1
8. SOIL DISTURBED AFTER THE INITIAL TREATMENT SHALL BE RETREATED INCLUDING
SPACES BOXED OR FORMED, FBC 1816.1.2
9. BOXED AREAS IN CONCRETE FLOORS FOR SUBSEQUENT INSTALLATION OF TRAPS, ETC.,
SHALL BE MADE WITH PERMANENT METAL OR PLASTIC FORMS, PERMANENT FORMS
MUST BE OF A SIZED AND DEPTH THAT WILL ELIMINATE THE DISTURBANCE OF S❑IL AFTER
THE INITIAL TREATMENT. FBC 1816.1.3
10, MINIMUM 6 MIL VAPOR RETARDER MUST BE INSTALLED TO PROTECT AGAINST RAINFALL
DILUTION. IF RAINFALL OCCURS BEFORE VAPOR RETARDER PLACEMENT, RETREATMENT IS
REQUIRED. FBC 1816.1.4
11, CONCRETE ❑VERP❑UR AND MORTAR ALONG THE FOUNDATION PERIMETER MUST BE
REMOVED BEFORE EXTERIOR SOIL TREATMENT, FBC 1816.1.5
12. S❑IL TREATMENT MUST BE APPLIED UNDER ALL EXTERIOR CONCRETE OR GRADE
WITHIN 1'-0' OF THE STRUCTURAL SIDE WALL. FBC 1816.1.6
13, ALL EXTERIOR VERTICAL CHEMICAL BARRIER MUST BE INSTALLED AFTER CONSTRUCTION
IS COMPLETE INCLUDING LANDSCAPING AND IRRIGATION. ANY SOIL DISTURBED AFTER THE
VERTICAL BARRIER IS APPLIED, SHALL BE RETREATED. FBC 1816.1.6
14. ALL BUILDINGS ARE REQUIRED TO HAVE PRE -CONSTRUCTION TREATMENT. FBC 1816.1.7
WITHIN 1'-0' OF THE STRUCTURAL SIDE WALL. FBC 1816.1.6
15. A CERTIFICATE OF COMPLIANCE MUST BE ISSUED TO THE BUILDING DEPARTMENT BY
A LICENSED PEST CONTROL COMPANY BEFORE A CERTIFICATE OF OCCUPANCY WILL BE
ISSUED. THE CERTIFICATE OF COMPLIANCE SHALL STATE, 'THE BUILDING HAS RECEIVED
A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN TERMITES. THE
TREATMENT IS IN ACCORDANCE WITH THE RULES AND LAWS OF THE FLORIDA
DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES.' FBC 1816.1.7
16. AFTER ALL WORK IS COMPLETE, LOSE WOOD AND FILL MUST BE REMOVED FROM
BELOW AND WITHIN 1'-0' OF THE BUILDING. THIS INCLUDES ALL GRADE STAKES TUB
TRAP BOXES, FORMS, SHORING, AND OTHER CELLULOSE CONTAINING MATERIAL. FhC 2303.1.3
17. NO WOOD, VEGETATION, STUMPS, CARDBOARD, TRASH, ETC., SHALL BE BURIED
WITHIN 15'-0' OF ANY BUILDING OR PROPOSED BUILDING. FBC 2303.1.4
WINDOW AND DOOR NOTES;
1. ALL EXTERIOR WINDOWS AND GLASS DOORS ARE REQUIRED TO BE TESTED IN
ACCORDANCE WITH ANSI/AMMA/NWWDA 101 /IS2 STANDARD AND BEAR AN
AMMA OR WDMA LABEL IDENTIFYING THE MANUFACTURER PERFORMANCE
CHARACTERISTICS AND APPROVED PRODUCT TESTING ENTITY.
2 ALL EXTERIOR WINDOWS AND DOORS, SHALL BE ANCHORED PER PUBLISHED
MANUFACTURER'S RECOMMENDATIONS TO ACHIEVE THE DESIGN PRESSURE SPECIFIED.
THE FOLLOWING SHALL BE CONSIDERED SPECIFIC HAZARDOUS LOCATIONS FOR
THE PURPOSES OF GLAZING. (FBC 2403,2)
1, GLAZING IN SWINGING DOORS AND FIXED AND SIDING PANALS OF SLIDING (PATIO)
DOOR ASSEMBLIES AND OTHER FACILITIES WHERE SUCH GLAZING IS LOCATED 36'
INCHES OR LESS MEASURED HORIZONTALLY FROM A STANDING SURFACE.
2. GLAZING IN DOORS AND WALLS OF ENCLOSURES FOR HOT TUBS, WHIRL POOLS,
SAUNAS, STEAM ROOMS, BATH TUBS, SHOWERS OR WALKING SURFACE WITHIN THE
ENCLOSURE AND WHERE THE BOTTOM OF THE EXPOSED GLAZING IS LESS THAN
60 INCHES MEASURED VERTICALLY ABOVE SUCH STANDING OR WALKING SURFACES,
3. GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL ADJACENT TO A DOOR
WHERE THE NEAREST VERTICAL EDGE IS WITHIN A 24 INCH RADIUS OF THE DOOR
IN A CLOSED POSITION AND THE WHOSE BOTTOM EDGE IS LESS THAN 60 INCHES
ABOVE THE FLOOR OR WALKING SURFACE.
EXCEPTIONiGLAZING IN WALLS PERPENDICULAR TO THE PLANE OF THE DOOR IN A
CLOSED P❑SITI❑N IN GROUP R-3/R-2 SHALL BE SUBJECT TO 2405.2.1 (4)
4. GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL OTHER THAN THOSE
LOCATIONS IN ITEMS 2 AND 3 ABOVE, THAT MEETS ALL THE FOLLOWING
C❑NDITI❑NSA
4.1 EXPOSED AREA OF AN INDIVIDUAL FIXED OR OPERABLE PANE GREATER
THAN 9 S.F.
4.2 BOTTOM EDGE LESS THAN 18 INCHES ABOVE THE FLOOR
4.3 TOP EDGE GREATER THAN 36 INCHES ABOVE THE FLOOR
4.4 ONE OR MORE WALKING SURFACES WITHIN 36 INCHES HORIZONTALLY OF
THE PLANE OF THE GLAZING
5. ALL GLAZING IN RAILINGS REGARDLESS OF AREA OR HEIGHT OR AREA ABOVE A
WALKING SURFACE INCLUDING STRUCTURAL BALUSTER PANELS AND
NON-STRUCTURAL IN -FILL PANELS.
6. GLAZING IN WALLS AND FENCES ENCLOSING INDOOR AND OUTDOOR SWIMMING
POOLS AND SPAS WHERE THE BOTTOM EXPOSED EDGE OF THE GLAZING 18 (1)
LESS THAN 60 INCHES ABOVE A WALKING SURFACE ON THE POOL SIDE OF THE
GLAZING AND (2) THE GLAZING IS WITHIN 60 INCHES HORIZONTALLY OF THE
WATERS EDGE OF A SWIMMING POOL OR SPA. THIS SHALL
BE APPLY TO SINGULAR GLAZING AND ALL PANES IN MULTIPLE GLAZING.
SEE FBC 2405.2 FOR PRODUCTS, MATERIALS AND USES THAT ARE EXEMPT FROM
THE ABOVE HAZARDOUS LOCATIONS.
EXTERIOR WINDOWS & DOORS
1. ALL EXTERIOR WINDOWS AND GLASS DOORS ARE REQUIRED TO BE TESTED IN
ACCORDANCE WITH ANSI/AMMA/NWWDA 101 /IS2 STANDARD AND BEAR AN
AMMA OR WDMA LABEL IDENTIFYING THE MANUFACTURER PERFORMANCE
CHARACTERISTICS AND APPROVED PRODUCT TESTING ENTITY.
2. ALL EXTERIOR WINDOWS AND DOORS WHERE BUCK THICKNESS IS LESS THAN 1 1/2'
THICK, SHALL BE ANCHORED THROUGH THE JAM INTO THE STRUCTURAL SUBSTRATE.
3. ALL EXTERIOR WINDOWS AND DOORS WHERE BUCK THICKNESS IS 1 1/2' OR GREATER, THE
BUCK MUST BE ATTACHED IN A MANNER THAT TRANSFERS THE LOAD DIRECTLY TO THE
STRUCTURE, WINDOWS AND DOORS SHALL BE ANCHORED THROUGH THE JAM INTO THE WOOD BUCK,
4. THE WINDOW BUCK SHALL EXTEND BEYOND THE INTERIOR LIP OF THE WINDOW.
5. MULLIONS AND ADJACENT DOOR ASSEMBLIES ARE REQUIRED TO BE TESTED OR
ENGINEERED TO TRANSFER 1.5 TIMES THE DESIGN LOADS TO THE ROUGH OPENING SUBSTRATE.
INDEX
CONTRACTOR IS TO VERIFY ANY STRUCTURAL
OR CODE REQUIREMENTS PRIOR TO CONSTRUCTION, AND TO BUILD ACCORDINGLY.
CONTRACTOR TO VERIFY DIMENSIONING PRIOR TO CONSTRUCTION AND TO
NOTIFY OWNER & ENGINEER FOR ANY DIMENTI❑NAL CORRECTIONS PRIOR
TO CONSTRUCTION.
BUILD - OUT
SHT# ARCHITECTURAL
1 Al TITLE / GENERAL INFORMATION
2 A2 FLOOR PLAN - FIRE SAFETY PLAN
3 A3 PLUMBING - WALL SECTIONS
4 A4 ELECTRICAL PLAN
Please be advised this review of plans submitted is s
on" to assist the contractor in compliance wNh
applicable fee safety codes. This review is not intended
to be a final appcval of the submitted plans. It is the
cwtaclor's sole responsibility to ensure that the plans are in
cornpleb compliance with al applicable NFPA codes and
loaf adinences. In the went that further examination or
she inspection reveals areas of non -Compliancy:, it shall be
CM*acws sole responsibility, at their sole expense to
bring those areas in compliance. The City assumes no
regvm biMty for the contractor's failure to be in compliance
with aN applicable NFPA Codes and local ordinances.
iUBM=ED PLAN(S) HAV BEEN REVIEWED
BY ZEPHYRHILLS AL'S OFFI
Date:
Rediewer:
ALL WORK SHALL COMPLY WITH ALL
PREVAILING CODES, FLORIDA BUILDWG
CODE, NATIONAL ELECTRIC CODE AND
CITY OF ZEPHYR HILLS ORDINANCES
DESIGN PLANS BY RICK
813- 765-9793
ENGINEERS NOTES JOB NO.
2007-C10
SCALE DATE SHEET 1 OF 24
24 1 E 2997
DESIGN/DRAWN CHECKED A 1
R. GOLLHARDT
�I
N❑TEi FIRE EXTINGISHER MODEL 10MB-8H
BADGER 101b MULTI PURPOSE ABC OR EQUIL.
FE FIRE EXTINGUISHER
EDIRECTIONAL SYHMTBOLL
EXIT REEDRRR�MLFW T�KT
EMERGENCY LIGHTING
R
RFEEDAFR❑MLLIGHT TCKTY
FEEDDAFROMLLIGHT T�KT
I J
W
>m
Q6
_ aeo
I am
cd
aX
z
o.
sn
o�
U
LIFE SAFETY PLAN
1 LJnl 10 CIOC ACCCAAIDI V
EXISTING DOORS AND STOREFRONT WINDOWS I
0'-0
FLOOR PLAN
2880 S. F.
6
(2) 2'X4' TOP PLATE (C❑NT)
2X4 STUD WALL @ 16' O.C.
WITH 1/2' GYPSUM BD
2' X 4' PT BOTTOM PLATE
ATTACHED W/ C❑NC NAILS
2X4 CEILING @ 24' O.C.
W/ 1/2' CEILING TYPE GYPSUM BD,
R-30 BATT INSULATION (MIN)
1/2' GYPSUM WALLBOARD
R-11 INSULATION IN WALLS
CIF REQUIRED FOR SOUND PR❑❑FING)
EXISTING C❑NC FLOOR
TYPICAL WALL SECTION
(2) 2'X4' TOP PLATE (C❑NT)
2X4 STUD WALL @ 16' O.C.
WITH 5/8X' GYPSUM BD
CUL )
2' X 4' PT BOTTOM PLATE
ATTACHED W/ C❑NC NAILS
2X4 CEILING @ 24' O.C.
W/ 5/8X' CEILING TYPE GYPSUM BD,
CUL )
R-30 BATT INSULATION (MIN)
5/8X' GYPSUM WALLBOARD
R-11 INSULATION IN WALLS
CIF REQUIRED FOR SOUND PR❑❑FING)
EXISTING C❑NC FLOOR
TYPICAL WALL SECTION
FIRE WALL ASSEMBLY
rjsljifm�
ALL PLUMBING FIXTURE LOCATIONS ARE TO BE DETERMINED BY THE PLUMBING CONTRACTOR,
THE PLUMBING CODE REQUIRES THAT AT LEAST ONE 3' VENT STACK PIPE WILL BE
VENTED THROUGH THE ROOF,
IN ACCORDANCE WITH CHAPTER 471.003 (2) OF THE FLORIDA ADMINSTRATION CODE,
PLUMBING SYSTEMS SHALL BE DESIGNED BY THE
RESPECTIVE CONTRACTORS TO MEET ALL APPLICABLE CODES, THE SYSTEMS DRAWN
HEREON ARE BASED UPON THE HOMEOWNERS/CONTRACTORS REQUIREMENTS,
ALL FIXTURE LOCATIONS MUST BE VERIFIED FROM FLOOR PLAN AND IS THE RESPONSIBILITY OF
PLUMBING CONTRACTOR TO PLACE FIXTURES IN CORRECT L❑CATI❑N, PLUMBING DRAIN LAYOUT
WILL BE DETERMINED IN FIELD BY CONTRACTOR,
DESIGN PLANS BY RICK
813-765-9793
PLUMBING
WALL SECTION
SHEET OF
SCALE
1/4 pp= i $-Opp
DESIGN/DRAWN CHECKED
R. GOLLHARDT
JOB NO.
j