HomeMy WebLinkAbout5208 8th St8TH STREET O z m m 3' x 1 z G'1 z ec --�--- I EXISTING DIRT ALLEY C m z C m • SCOPE OF WORK 1- REMOVE EXISTING IMPROPERLY FRAMED WALL FLOOR TO CEILING 2- REPLACE WALL WITH NEW 2X4 STUDS @ 16" OC AND 1/2" DRYWALL EACH SIDE 3- PROVIDE NEW SUPPORT FOR EXISTING LOW CEILING JOISTS IN BACK ROOM AND REPAIR EXISTING DRYWALL CEILING AS REQUIRED 4- REPAIR SUSPENDED ACOUSTICAL CEILING IN LARGE FRONT ROOM 5- PROVIDE TOP BLOCKING AS REQUIRED TO SUPPORT TOP OF NEW WALL 6- FINISH AND PAINT NEW WALL 7- INSTALL ELECTRICAL IN NEW WALL PER SEPERATE PLAN TO BE SUBMI IT ED BY ELECURICIAN AND MADE A PART OF THIS PERMIT Happy Science Church 5208 8th Street Zephyrhills, Florida 33542 ,i LEGAL DISCRIPTION CITY OF ZEPHYRHILLS PB1PG54 LOTS 22 23 &24 BLK 183 OR 9616 PG 1510 ALL CODES F SHALLRIDA COMPLY WR NATIONAL ELEC BUILDING CODEPR�/AIUNG AND r rRIC COD, ORDINAN&ES OF ZEPNy�ILLS I-RCVIEW DATE DEC 14 2016 CITY OF zEpMYRILLS PLANS EXAMINER lir��c Cli5et OUR& DISH Or. 1,1TA ENGINEERING alssaH A. Ferllta P.E./ 47075 .:;GI N. norida Av. i I'A, FLORIDA 33803 IONIC (813) 234-5004 11 CHAPTER 1, SECTION 105.0 N ILNT. A paint owed sld be d W be a Ice— to poceedrih 0x 1 nd as euthorty 10 violate. cancel doer. Ile any of the pfovislons of Me Ld," or shell Imam. of a pains pwathe shn A hom dureaf ar'.9. p e n of en ues m ",". cadsadbn a . el Zcab scwnenls are nut o, NO Mm, dt re n,.Id.d to pubk ege— rs6receAe .vie, comments and tt�pdA— u,—ts niay e.b3eq-.1ybe(rAsedby woi to Wed resohAim ofb es MOM r epencles pane IC end echo try er hanpes, reml— and mWILA.. t may pompl addib-idocu m I We apeney approval aco. an Qw s.am unnenls shall not be fled lu pt* tl0-9 the engineer drewds pC an0 CMise1 03 z O F-- U I- U (10 M z "f n (� a (.) z J IY o E w � Ill J o " z 11J � w c J 0 Tb L. U L1J O• (n N) O L n DRAWING SETS DATE NOVEMDER I, 2018 I ENGINEERING kF _ kA1 � v w U Z Lu N, U w (n , '- N J = J I- F- _ (Y' o Q CL Z In N 1 IIGINEERS SEAI- �,,,,►,Tltlltt,,, J� I�O�HdE{ 2018 Al I SHEET NUMBER OF r) BACK ROOM I I I � i EXISTING I 2X10 I FLOOR JOISTS i I i I I @ 2' OC I 1 I �A I ' ' i I I I I 1• •i EXISTING CONCRETE SLAB -ON GRADE EXISTING FLOOR PLAN FLOOR FRAME PLAN SCALE 1/8" =1' SCALE 1/8" =1' 8111X 8" CONT BEAM i ACROSS PIERS I ' 'I I i i 'u F62 SDllIC10RAl. DEM 8Y: FEBLITA ENGNMG Russell A. Ferlito P.E.# 47075 4221 N. Florid, Av. A1lPA FLORIDA 33003 Tin (013) 256-5004 FBC2010 CHAPTER 1.6EC11DNMI PERIffrN19 . A pamk beuod dYlbe canebued IR bo a kwae to pomedeerkm wok and not uadm to vbblr, clod dr, oral add, aay d tlm prvdelau dMtrdelyd codes, nor ehal bwmce of pmrdpeeatb b i&V olkd ham Ihemdam4ttga wmdlon of em a In pmk caabraln m 'A' , eafftada Tlueo demarmab am rat In knd6nq btme be" bwmkbd to pdtkc spendsbWIW apeaayredewe,commentandbtap IN i The doamenb may edoepwn0/bamdmdby OW enpbeerb relied MOA Mdbarseer to pubk akmcMa pdar to Andedmbyh apends dunks, mdcbs mdmmem& eb a levied may prompt adbkoddlamat a bdwfarokencyepprwelmomanhemm peJed These doammb Ad ad be bdbrp6ke recadwthadMe onghwafrsadc baodedkoaNcaaat W O 1— U Cr U F-- J N z _j W rM O UZ o F Z wQ. t p oacooIn 0 __I _ O w Mc O.rnLt DRAWING SETS DATE NOVEMBER I, 2018 ENGINEERING DESIGr6R: DF DRAWN BY: R BY: PROJECT NO. LED V x U w z CIQ w Uj crLL U� IL co aco aIL Lo N Al SHEET NUMBER 0F j EXIS 2x4 SECTION 1-1 EXISTING FRAMING EXISTING FOUNDATION PIERS @ 101 OC TYP EACH WAY SCALE 1/411= 1' t .00K tA13I11417 L AL A lb LUNU FUUIVL)A I IUN NAU EXISTING ACOUSTICAL CIELING. REPAIR AS REQUIRD 2X4 FIREBLOCK FRONT ROOM O INSTALL NEW 2X8 LEDGER BOARD WITH SIMPSON LUS 2X8 HANGERS AT EA EXISTING JOIST _Y REPAIR EXISTING DRYWALL CEILING AS REQUIRED NEW WALL OF 2X4 @ 16"OC W/ 1/2" DRYWALL EA SIDE BACK ROOM I EXISTING 2X10 FLOOR JOISTS @ 2' OC L�--- EXISTING 20" SQ FILLED CONCRETE FOUNDATION BLOCK EXISTING 2'X2'X 16" CONC FOUNDATION PAD SECTION 1-1 NEW WALL SCALE 1/411= 1' K11432%2 STRUCTURAL DESIGN BY: ffUA ENGINEERING Russell A. Ferllta P.E., 47075 4221 N. Florida Av. TAMPA, FLORIDA 33003 PHONE (B13) 234-5004 FUC 2010 CHAPTER 1. SECMN 10i11 PERl4T 1NTEHT. A pe m4lseued Mdbe cat<sWed to be a Incense to 1•otted•A pre wmk end not m autharty to viotah%earn( der, or s4 aside my of the prmAslom dte IednlW cdn, nor 5he0 tesuence of a pmnl pe t0. bupdmg offiul from 1tweaftrYargA ge cortcNon of mon N plans, mnst dkn or dolebam of Nb ode These documeah mm not In ford fmn, hu m bring pansmftled to pubic ag,ad. bam6m agency rr ef—, commenb and kt patai The documents may subseque* be"sanfby me engineer to m9ect resohd an of k—tl the puh0c agencln pd., to find odm by It. egenclrs chmges, revisions and mwr-b nbs • projed maY Prompt adddord dmet ,utrmA' 1faregrncyappmvoladurmpresnnr pmJed These doaanenb shad nol be Ned brpt@ rtcnN w;ihatrt the enginetrdrrmds Imowedge and cma t 03 Z O U U () —J J n Z W M O U Z �o f W J o Z W _r O Q rn —I O j yU = / U J 00 Lu DRAWING SETS DATE NOVEMBER I, 2018 ENGINEERING Dell GN7R DF DRAWN BY: RF C.-aEo Br: PRo.rcr No. RAF U z U LLI Z � Lu U w TI � J [^L F 2 EL W Qm � s a IL CV W 2 IIJ fV `IU§HIJKT ZUI(b� X� SHEET NUMBER OF 4 I BLOCKING AS REQUIRED T( SIMPSON LUS 2X8 HANGERS INSTALL NEW 2XI F NE EXISTING 2X10 I 8' A( EXISTING 20" SQ FILLED CONCRETE FOUNDATION BLOCK EXISTING 2'X2'X 16" CONC FOUNDATION PAD ELEVATION A SCALE 1/4 =1' IR III WO 62 SMMR& DESIGN 8Y: FMA ENGIlVEERING Russell A. FeFllto P.E., 47075 4221 N. Florida Av. TAMPA. Fl40RMA 33003 PHONE (813) 234-60D4 FIC 2016 CHAPTER 1, /EC110N 101AI PERAUTORENL Apermkbweddelbe cmehuedto be • kmx topooeedolblm Work and flat uari to vbdete,emrorl ow ora1nlde&1ydl1pmebbmdlw, - coda, nor ehdl beuern de pemtpevmeb Wkim oftel hom Merakerm ofte cmmt0an demm In pane. omekdelor W dons of lbcode. These docmnenb erorot b rkrdkero,bdme heklp bemmNed topubk ependeslo epmgfvvW ,commembemdbkrpetelma The docunmb mmy eubsepuemyb@mbWby W er0wertomled reedrdlmdbmoovO 0m pubk e/enda pdmb Indedelbylm ependa chorlla, revblorre end madr�meb e plekd mey prompt addimd doomel abmltd br Mency opprowd odmonlmpme project Thm dommrmb dml not he bodkrplk record wMmd&o en&emdm ntf bmelodleondcemol '0 z _O V ZD cn --I J Z M O CD 4 V Z W J O LLJ u Z V w Q yim'D7 J =O V' U w n oD — LLJ _ � acoMo w1 3 av DRAWING SETS DATE NOVEMBER I, 2018 ENGINEERING DESIGNER: DF DRAWN BY: RF CMECNED BY: PROJECT No. RAF D U LU z UJ LU (� LU U- to J = J CL FY o Q � W ScV 1c7 N ENGINEERS SEAL N0VH4E-T 201E Aq SHEET NUMBER OF LIST OF ABBREVIATIONS = CONTROL JOINT O.F. C.J. CL. = CLEAR REINF. COL. = COLUMN SECT. CONST. JTCONSTRUCTION JOINT STL. DET. = DETAIL TEMP. DWG. = DRAWING U.O.N. E.W. = EACH WAY WWF EL. = ELEVATION qp F.F. = FINISHED FLOOR !l O.C. =ON CENTER B.O.B. =OUTSIDE FACE = REINFORCING = SECTION = STEEL =TEMPERATURE = UNLESS OTHERWISE NOTED =WELDED WIRE FABRIC =CENTERLINE OF SYMETRY = BOTTOM OF BEAM All Materials, Workmanship, Design and Construction Shall Conform to the Drawings, Specifications FBC 2017, 6th Edition. DESIGN LOAD CRITERIA Roof Live Load_ 20psf Floor Live Load 125psf Roof Dead Load 15psf Corridor Live Load 125 psf Structural Drawings Shall be Used in Conjunction With Architectural Drawings For Bidding And Construction. Contractor Shall Verify Dimensions and Conditions For Compatibility and Shall Notify Architect of Any Discrepancies Prior to Construction Contractor Shall Verify All Existing Conditions Prior to Commencing Any Work And Determine The Location of All Adjacent Underground Utilities Prior to Commencing Excavation, and Notify Architect of Discrepancies and Conflicts. Contractor Shall Provide Temporary Bracing for the Structure and Structural Components Until All Final Connections Have Been Completed in Accordance With the Plans. Contractor Shall be Responsible for All Safety Precautions And The Methods, Techniques, Sequences or Procedures Required to do The Work. Shop Drawings For Structural Steel, Roof Structure And Floor Structure Shall Be Submitted to The Architect And/or Structural Engineer For Review Prior to Fabrication of Approval of These Items. All Shop Drawings Shall Also be Submitted to The Building Department. Shop Drawings Review: Dimensions and Quantities are Not Reviewed by The Engineer of Record, Therefore Must be Verified by The Contractor. Contractor Shall Review and Stamp Drawings Prior to Review by Engineer of Record. Submittals Shall Include a Reproducible And One Copy. Reproducible Will be Marked And Returned. Shop Drawings Submittals Processed by The Engineer Are Not Change Orders. The Purpose of Submittal by The Contractor is to Demonstrate Understanding of the Design Concept, The Materials Intended to be Furnished and Installed, and to Detail The Intended Fabrication And Installation Methods. If Deviations, Discrepancies, or Conflicts Between Shop Drawing Submittal And The Contract Drawings Are Discovered Either Prior to, or After Shop Drawing Submittal Are Processed by The Engineer, The Design Drawings And Specifications Shall Control And be Followed. GEOTECHNICAL Foundation Notes: The Structural Engineer And Architect Assume no Responsibility For Geotechnical. Allowable Soil Pressure And Pile Capacity Listed Below Are Assumed Design Values. Verification by a Qualified Soils Engineer is Strongly Recommended. Allowable Soil Pressure _ Pile Compression Capacity Pile Lateral Capacity 2,000 psf 10 Tons 2 Tons CONCRETE Concrete Shall be Mixed, Proportioned, Conveyed and Place in Accordance With ACI 318-14 Chapter 19. Concrete Shall Attain a 28 Day Strength of F'c = 3,000psi And Shall be Proportioned to Produce a Slump of 6" or Less Reinforcing Steel Shall Conform To ASTM 1615, Grade 60, Fy = 60,000psi. Welded Wire Fabric Shall Conform To ASTM A-185. Reinforcing Steel Shall be Detailed (Including Hooks and Bends) in Accordance With ACI 315-80 and 318-83, Lap All Continuous Reinforcement 48 Bar Diameters or 27" Minimum. Lop Adjacent Mats of Welded Wire Fabric A Minimum of 8" at Sides And Ends. Concrete Protection (Cover) For Reinforcing Steel Shall be as Follows: Footings And Other Unformed Surfaces, Earth Face All Other Surfaces — 3" 1— 1 /2" Epoxy —Grouted Items Specified on The Drawings Shall be Grouted With HS-200 Bond Epoxy by Bond —It Fastening Systems, Adhesives Technology Corporation or Equal. Install in Strict Accordance With Manufactures Recommendations. MASONRY Masonry Shall be Constructed of Grade N, Type II Units, Laid up in Running Bond. Mortar Shall be Type M or S And Shall Attain a Minimum Compressive Strength of 2,000psi at 28 Days. Strength Shall be Verified by Prism Testing. Masonry and walls adjacent to cathedral or vaulted ceilings must extend to the ceiling. Unless Otherwise Noted, Reinforce Walls With #5 Rebar at Each Corner And at 8 Feet Minimum Vertical Spacing. Rebor Shall Extend From Footing to Lintel And Hooked at Each End. Horizontal Reinforcement, Such as DuroWoll, Shall be Used at 16" Vertical Spacing. Fill All Cells Containing Reinforcement or Embedded Items With Concrete Grout. Provide Clean Out And Inspection Holes at Bottom of All Masonry Wall CMU Cells Containing Reinforcement. Roofing Roofing must be strong enough to stay intact in the estimated highest winds of the area by the manufacture's installation instructions and test data that proves the strength of the shingle. STEEL Structural Steel Design, Fabrication And Erection Shall be Based on The Latest Editions of The AISC Specifications and Codes: 1. Specifications For Structural Steel Buildings — Allowable Stress Design 2. Code of Standard Practice For Steel Buildings and Bridges, Amended. 3. Specification For Structural Joints Using ASTM A325 or A490 Bolts. Structural Steel Including Plates And Rolled Shapes, Shall Conform to ASTM A50, Fy=50ksi. Steel Pipe Shall Conform to ASTM A53, Type E or S Grade B, Fy-35ksi. Structural Tubing Shall Conform to ASTM A500, Grade B, Fy=46ksi. Anchor Bolts and Connection Bolts Shall Conform to ASTM A307. All Welding Shall be in Conformance With ASIC and AWS Standards And Shall be Performed by WABO Certified Welders Using E70 Electrodes. Only Prequalified Welders (As Defined by AWS) Shall be Used. WOOD Dimensioned Lumber Shall be Dressed S4S And Shall Bear The Grade Stamp of the Suppliers Association. All Lumber Shall be Sound And Free From Warp. All Lumber Shall be Southern Pine Grade No. 2 or Better With The Following Minimum Properties (U.O.N.): Fb= 850psi Fv= 165psi GENERAL STRUCTURAL NOTES: WOOD CONTINUED Plywood Sheathing Shall be DFPA CD With Exterior Glue. All Roof Sheathing Shall be Installed With PlyClips Between Framing Members Spaced Greater Than 16"o.c. Install Bridging in All Floor And Roof Joists ® 8'— 0" o.c. Maximum. Install Blocking in All Wall Studs at Plywood Edges. All Nailing And Bolting Shall Comply With American Institute of Timber Construction Requirements. Provide a Single Plate at The Bottom And a Double Plate at The Top of All Bearing Stud Walls. Studs Shall be Doubled at All Angles And Around All Openings. Studs Shall be Tripled at All Comers. Install All Connectors And Ties as Per Manufacturer to Their Highest Capacity. If Wood Shows Evidence of Cracking From Fasteners, Pre Drill For Fasteners or Use Self —Tapping Fasteners PRE—ENGINEERED WOG, Codes And Standards: a. National Design Specification For Wood Construction Latest Edition. b. Design Specifications For Metal Plate Connection Wood Trusses, TPI-85, Published by The Truss Plate Institute. c. HIB — 01, Published by The Truss Plate Institute. d. All Requirements of Truss Plate Institute. Maximum Deflection: Live Load L/360 Dead Load _ L/240 Design Wood Trusses For The Loads Shall Meet Wind Loads Shown on The Drawings. Truss Erector is Responsible For The Temporary Bracing of The Trusses. Truss Manufacturer Shall Clearly Show The Size And Location of All Required Top And Bottom Chord Bracing. Truss Manufacturer Shall Provide All Connections, Hangers, Header, Beams, etc. in Order to Complete The Floor Framing as Shown on Drawings. Submittal: Detailed Shop Drawings Showing Layout, Bridging, Connection Details, And All Accessory Materials to to Safely Complete The Floor System. Provide Calculations and Drawings Signed And Sealed by a Licensed Florida Engineer Registered in The State of Florida. GLUE LAMINATED MEMBERS Shall be Fabricated in Conformance With FBC Standards. Each Member Shall Bear an AITC Identification Mark And Shall be Accompanied by an AITC Certificate of Conformance. All Simple Spans Beams Shall Be Douglas Fir Combinations 24F—V4, Fb=2,400 psi, Fv=165 psi. Laminated Veneer Lumber (LVL) Shall be Manufactured Under a Process Approved by The National Research Board. Each Piece Shall Bear A Stamp or Stomps Noting The Name And Plant Number of The Manufacturer, The Grade, The National Research Board Number, And The Quality Control Agency. All Laminated Veneer Lumber Shall be Manufactured in Accordance With NER-126 Using Douglas Fir Veneer Glued With a Waterproof Adhesive Meeting The Requirements of ASTM D2559 With All Grain Parallel With The Length of The Member. Fb=2,600 psi, E=1,800,000 psi Fv= 285 psi (For 1.8E Members) Fb=2,985 psi, E-2,000,000 psi, Fv=285 psi (For 1-3/4" Wide 2.0E Members) Fb-2,485 psi, E=2,000,000 psi, Fv=285 psi (For 3 1 /2" Wide 2.0E Members) Design Shown on Plans is Based on Lumber Manufactured by the Trus—Joist Corporation. Alternative Manufacturers May be Used Subject to Review And Approval by The Architect And/or Structural Engineer. Alternate Joist Hangers And Other Hardware May be Substituted For Items Shown Provided They Have I.C.B.O. Approval For Equal or Greater Load Capacities. All Joist Hangers And Other Hardware Shall be Compatible in Size and Loads With Members Provided. PARALLEL STRAND LUMBER (PSL) Shall be Manufactured Under a Process Approved by The National Research Board. Each Piece Shall Bear a Stamp or Stamps Noting The Name And Plant Number of The Manufacturer, The Grade, The National Research Board Number, And The Quality Control Agency. All Laminated Veneer Lumber Shall be Manufactured in Accordance With NER-126 Using Douglas Fir Veneer Glued With a Waterproof Adhesive Meeting The Requirements of ASTM D2559 With All Grain Parallel With The Length of The Member, Fb= 2,900 psi, E=2,000,000 psi, Fv=290 psi (For 2.0E Members Fb= 3,100 psi, E=2,100,000 psi, Fv=290 psi (For 2.1E Members Design Shown on Plans is Based on Lumber Manufactured by The Trus—Joist Corporation. Alternate Manufacturers May be used Subject to Review And Approval by The Architect And/or Structural Engineer. Alternate Joist Hangers And Other Hardware May be Substituted For Items Shown Provided They Have I.C.B.O. Approval For Equal or Greater Load Capacities. All Joist Hangers And Other Hardware Shall be Compatible in Size With Members Provided. PRE—ENGINEERED TRUSSES Pre —Fabricated Connector Plate Wood Roof Trusses Shall be Designed by the Manufacturer in Accordance With the Design Specification For Metal Plate Connected Wood Trusses, TPI-78, by The Truss Plate Institute for The Spans And Conditions Shown on The Plans. Wood Trusses Shall Utilize Approved Connector Plates, Submit Shop Drawings to The Architect And/or Structural Engineer For Review Prior to Fabrication, Submitted Documents Shall Bear The Stamp And Signature of a Registered Professional Engineer Registered in The State of Florida. Provide For Shapes, Bearing Points, Intersections, Hips, Volleys, etc. Shown on The Drawings. Exact Composition of Special Hip, Valley, And Intersection Areas (Use of Girder Trusses, Jack Trusses, Step —Down Trusses, etc.) Shall be Determined by The Manufacturer Unless Specifically Indicated on Plans. Provide All Truss to Truss And Truss to Girder Truss Connection Details And Required Connection Materials, Provide For All Temporary And Permanent Truss Bracing And Bridging. Exterior Plywood Sheathing Shall be Grade C—D, Exterior Glue or Structural II. Exterior Glue. Timber Connectors Indicated by Letters And Numbers Shall be Strong Tie by Simpson Company, as Specified in Their Catalog. Equivalent Devices by Other Manufacturers May be Substituted, Provided They Have I.C.B.O. Approval For Equal or Greater Load Capacities. Provide Number And Size of Fasteners as Specified by Manufacturer. Connectors Shall be Installed in Accordance With The Manufacturer's Recommendations. Bolts in Wood Members Shall Conform to ASTM A307. Provide Oversize Washers Under The Heads And Nuts of All Bolts And Lag Screws Bearing on Wood. Unless Noted Otherwise, All Nails Shall be Common, All Shims Shall be Seasoned And Dried And of The Some Grade (Minimum) as The Members Connected. All Joists Shall be Connected To Flush Beams With Joist Hangers, Unless Otherwise Noted. Wood Framing Notes: The Following Apply Unless Otherwise Noted on The Plans: All Wood Framing Details Not Shown Otherwise Shall be Constructed to The Minimum Standards of The 2017 Florida Building Code. Minimum Nailing, Unless Otherwise Noted, Shall be Common. Coordinate The Size And Location of All Openings With Mechanical And Architectural Drawings. Provide Washers Under The Heads And Nuts of All Bolts And Lag Screws Bearing on Wood. Fc= 565 psi FOUNDATION IN51'ECTION E= 1,200,000 psi FRAMING INSPECTION A FOUNDATION 5URVEY SHALL BE PERFORMED AND NOTE: TO THE BEST OF 7HE ENGINEERS KNC)MEDGE s 11 `% Maximum Moisture Content A COPY OF THE SURVEY 511ALL $E ON 171E 517E BELIEF, I TIE 5TRLK TURAL FLANS ! 51"ECIFICAI IONS All Wood in Contact With Concrete or Masonry Shall be Pressure Treated. ' NOTE: ALL PLUMBING, ELCCTRICAL ML) MECHANICAL ROUGH-IN5 FOR THE BUILDING INSPECIOR'S USE OR ALL COMPLY NTH THC PLORIDA BUILDING,, CODE, J Pressure Treated Lumber Shall be Impregnated With a CCA Salt Treatment in Accordance With F.S. TT—W-571 ALL W'OR.K SHALL COMPLY WITH PREVALING COOLS, LOCAL ML✓.iT BE COMPLEI E, IN5PECTOD AND APPROVm tJC1'ORE RCOUE511NG THE FRAMING IN5PEC7ION. FTX: 2017. LTH PROPERTY MARKCRS SHALL BE EXPOSED AND A 5TRLTC,HCD FROM MARKER TO MARKER lO FBC 2017, 6Th.LDITION, CATEGORY III And Bear The American Wood Preserves Institute Quality Mark LP-2. BUILDING t ALUMINUM. ELATION, CHAPTERS. 5MING CHAFTVIZ 5. ENFY URE'C' WIND ZONE 140 MPH WINDS. Wood Framing Notes Continued Wall Framing: All Studs Walls Shown And Not Otherwise Noted Shall be 2X4 Studs at 16"o.c. Two Studs Minimum Shall be Provided at The End of All Walls And at Each Side of All Openings, Solid Blocking For Wood Columns Shall be Provided Through Floors to Supports Below. Provide Solid Blocking Between Studs at Mid —Height of All Stud Walls Over 8 ft in Height. All Stud Walls Shall Have Their Lower Wood Plates Attached to Wood Framing Below With 16d Nails at 12"o.c. Staggered or Bolted to Concrete With 1/4"X 3-1/4" Top Cons at 16"o.c. Unless Otherwise Noted. Members of Built —Up Posts Shall be Nailed to Each Other With 16d at 12"o.c. Staggered. Refer to The Plans And Shear Wall Schedule For Required Sheathing And Nailing. When Not Otherwise Noted, Provide Gypsum Wallboard on Interior Surfaces Nailed to Al Studs, Top And Bottom Plates, And Blocking With Nails at 7"o.c. Use 5d Cooler Nails For 1/2" GWB And 6D Cooler Nails For 5/8" GWB. Provide 1/2" Plywd Sheathing on Exterior Surfaces Nailed at All Panel Edges (Block Unsupported Edges), Top And Bottom Plates With 8d at 4"o.c., And to All Intermediate Studs And Blocking With 8d at 8"o.c. Allow 1/8" Spacing at All Panel Edges And Ends. Floor And Roof Framing: Provide Double Joist Under And Around All Openings in Floors or Roofs Unless Noted Otherwise. Provide Bridging a 8 ft o.c. And Solid Blocking at All Bearing Points. Toenail Joist to Supports With Two 16d Nails. Attach Timber Joist to Flush Headers or Beams With Metal Joist Hangers in Accordance with Schedule. Nail All Multi —Joist Beams Together With 16d at 12"o.c. Staggered. Unless Noted Otherwise on The Plans, APA Rated Roof And Floor Sheathing Shall be Placed With Strength Axis Perpendicular to Supports And Nailed With 8d Nails at 6"o.c. to Framed Panel Edges And Over Stud Walls as Shown on Plans And at 12"o.c. to Intermediate Supports. Provide Approved Plywood Edge Clips Centered Between Joist/Trusses at Unblocked Roof Sheathing Edges. All Floor Sheathing Edges Shall Have Approved Tongue —And —Groove Joints or Shall be Supported With Solid Blocking. Allow 1/8" Spacing at All Panel Edges And Ends of All Roof And Floor Sheathing. Toenail Blocking to Supports With (2)-16d at Each End or at 12"o.c. Unless Otherwise Noted. 1816.1 TERMITE PROTECTION— Termite protection shall be provided by registered termiticides. Including soil applied pesticides, baiting systems and pesticides applied to wook. or other approved methods of termite protection labeled for use as a preventative treatment to new construction. See Section 202. Registered termiticide. Upon completion of the application of the termite protective treatment, a Certificate of Compliance shall be issued to the building department by the licensed pest control company that contains the following statement: "The building has received a complete treatment for the preventin of subterranean termites. Treatment is in accordance with rules and laws established by the Florida Department of Agriculture and Consumer Services." 1816.1.1 If soil treatment is used for subterranean termite prevention, the initial chamical soil treatment inside the foundation perimeter shall be done after all excavation, backfilling and compaction is compolete. 1816.1.2 If soil treatment is used for subterranean termite prevention, soil area disturbed after initial chemical soil treatment shall be retreated with a chemical soil treatment, including spaces boxed or formed. 1816.1.3 If soil treatment is used for subterranean termite prevention, space in concrete floors boxed out or formed for the subsequent installation of plumbing traps, drains or any other purpose shall be created by using plastic or metal permanently placed forms of sufficient depth to eliminate any planned soil disturbance after initial chemical soil treatment. 1816.1.4 If soil treatment is used for subterranean termite prevention, chemically treated soil shall be protected with a miimum 6 mil vapor retarder to protect against rainfall dilution. If rainfall occurs before vapor retarder placemennt, retretment is required. Any work, including placement of reinforcing steel, done after chemical treatment until the concrete floor is poured shall be done in such manner as to avoid penetrating or disturbing treated soil. 1816.1.5 If soil treatment is used for subterranean termite prevention, concrete overpour or mortar accumulated along the exterior foundation perimeter shall be removed prior to exterior chemical soil treatment, to enhance vertical penetration of the chemicals. 1816.1.6 If soil treatment is used for subterranean termite prevention, chemical soil treatments shall also be applied under all exterior concrete or grade within 1 foot (305mm) of the primary structure sidewalls. Also , a vertical chameical barrier shall be applied promptly after construction is completed, including initial landscaping and irrigation/sprinkler installation. Any soil disturbed after the chemical vertical barrier is applied shall be promptly retreated. 1816.1.7 If a registered termiticide formulated and registered as a bait system is used for subterranean termite prevention. Sections R320.1.1 through R320.0.6 do not apply; however, a signed contract assuring the installation, maintenance and monitoring of the baiting system for a minimum of 5 years from the issue of the Certificate of Occupancy shall be provided to the building official prior to the pouring of the slab, and the system must be installed prior to final building approval. If the baiting system directions for use require a monitoring phase prior to installation of the pesticide active ingredient, the installation of the monitoring phase components shall be deemed to constitute installation of the system. 1816.1.8 If a registered termiticide formulated and registered as a wood treatment is used for subterranean termite prevention, Sections R320.1.1 through R320.1.6 do not apply. Application of the wood treatment termiticide shall be as required by label directions for use, and must be completed prior to final building approval. 1816.2 PENETRATION: 1816.2.1 Protective sleeves around metallic piping penetrating concrete slab —on —grade floors shall meet the following materials. 1816.2.2 If Soil Treatment is Used for Subterranean Termite Protection, the Protective Sleeve Shall Meet the Following Minimum Requirements: 1. The Sleeve Shall Hove a Nominal Thickness of 0.025 inch. 2. The Sleeve Shall be Sized for the Pipe. 3. The Sleeve Shall be Sealed Within the Slab Using a Noncorrosive Mechanical Clamping Device to Eliminate the Annular space Between the Pipe and Pipe Sleeve. ^EKINEMNG _V11"'_W a2se STRLC7tW l BY: 1+'ERI.ITA ENGINEERING RUSSELL FERLITA P.E./ 47075 4221 N. Florida Ave. TAMPA, FIARIDA 33603 PHONE (813) 234-5004 ENGINEERING gner. o e: SIVI-LP )rawn By: scde: LP See Plan >ecked By. Project No. RAF ki My 18 STRUCTURAL NOTES REVISION Components do Cladding - Method 1 h < 60 ft. Figure 30.5-1 F Net Desigh Wind Pressures Walls & Roofs Enclosed Buildings ZONE EFFECTIVE MIND AREA (SO. FT.) Net Ultlmete Design WffW i'ne aim pw QnQ Pin s,a r rt no - u) A50- 0,01MIN hate OMW am) Basic Wind Speed V (mph) 130 140 145 150 160 1 10.0 14.3 -35.3 0 ^ 1 20.0 13.4 -34.4 1 50.0 12.3 -33.2 (3) C 1 100.0 11.4 -32.3 Q 2 10.0 14.3 -59.2 4- 0 O 2 20.0 13.4 -52.9 2 50.0 12.3 -44.5 2 100.0 11.4 -38.2 3 10.0 14.3 -89.0 3 20.0 13.4 -73.8 3 50.0 12.3 -53.5 3 100.0 11.4 -38.2 1 10.0 20.3 -32.3 t^u I 1 20.0 18.5 -31.4 IS 1 50.0 16.1 -30.2 d 1 100.0 14.3 -29.3 2 10.0 20.3 -56.2 '+- O 2 20.0 18.5 -51.7 IX 2 50.0 16.1 -45.7 2 100.0 14.3 -41.2 3 10.0 20.3 -83.1 3 20.0 18.5 -77.7 3 50.0 16.1 -70.5 3 100.0 14.3 -65.1 1 10.0 32.3 -35.3 v I 1 20.0 31.4 -33.5 i, CU 1 50.0 30.2 - 31.1 1 100.0 29.3 -29.3 d c 2 10.0 32.3 -41.2 < 2 20.0 31.4 -39.4 0 2 50.0 30.2 -37.1 2 100.0 29.3 -35.3 3 10.0 32.3 -41.2 3 20.0 31.4 -39.4 3 50.0 30.2 -37.1 3 100.0 29.3 -35.3 4 10.0 35.3 -38.2 4 20.0 33.7 -36.7 4 50.0 31.6 -34.6 4 100.0 30.0 -33.0 d 4 500 26.3 -29.3 5 10.0 35.3 -47.2 5 20.0 33.7 -44.0 5 50.0 31.6 - 39.8 5 100.0 1 30.0 - 36.7 5 500 26.3 -29.3 1"",,,III'■Il,ll,ll.11,Lill' TRANSVERSE ELEVATIM LONGITUDINAL ELEVATION APPLICATION OF MAIN WIND FORCE RESISTING SYSTEM LOADS FOR SIMPLE DIAPHRAGN BUILDINGS TABLE 1609.3.1 EQUIVALENT BASIC WIND SPEEDS 3 sec. gust 85 90 100 105 110 120 125 130 140 145 150 fastest 110 115 129 135 142 155 161 168 181 187 194 Mite 1 mph - 9.447 Ns Main Wind Force Resisting System - Method 2 h S 60 ft. Figure 28.6-1 Design Wind Pressures Walls &Roofs Enclosed Buildings p 31"'Pllfted Design Wind Pre5&"- 16 (p5f) f'ftr�f Al M M aoJ&, SM LA WM A4.0) A50- 0.Mftmate 0et+gn VM) Basic Roof Zones Wind Speed Angle o Horizontal Pressures Vertical Pressures Overhangs (mph) (dW.) A 8 c D E F G H G H 0 to 51 1 31.1 -16.1 20.5 -9.8 -37.3 -21.2 -26.0 -1&4 -52.3 -40.9 Icr 1 3A7 -14.5 213 -&5 -37.3 -22.8 -26.0 -17.5 -52.3 -40.2 15• 1 1 39.0 -129 26.0 -7.4 -37.3 -24.2 -26.0 -1&8 -523 -40.9 140 20' 1 43.0 -11.4 2&7 -6.3 -37.3 -26.0 -26.0 -19.7 -52.3 -40.9 2S• 1 2 39.0 ....... 6.3 ...... 2&2 ...... 6.4 ...... -17.3 -6.6 -23.6 -12.8 -125 -1.8 -19.0 -8.2 -32.3 ...... -27.5 ...... 3W I. 4W 1 2 35.0 35.0 23.9 23.9 27.8 27.8 19.1 19.1 27 13.4 -21-2 -10.5 0.9 11.7 -1&2 -7.5 -723 -123 -14.0 -14.0 Roof Overhang Net Design Wind Pressure, p .,Jp50 Yia•'•• r A. +°a. M - "I A50- 0.QUIb note Deelge MM) Basic Wind Speed V (mph) EFFECTIVE ZONE MIND AREA (30. FT.) 130 140 150 160 2 10 -50.8 I 2 20 -49.9 0 ^ 2 50 -48.7 Go 2 100 -47.8 a 3 10 -83.7 3 20 -65.7 O O IX 3 50 -41.9 3 100 -23.9 2 10 -65.7 to 2 20 -65.7 2 50 -65.7 Or ap 2 100 -65.7 a 3 10 -110.6 4- 8 3 20 -99.8 3 50 -85.5 3 100 -74.7 2 10 -59.8 2 20 -58.0 tu 2 50 -55.6 g, 2 100 -53.8 o� C 3 10 -59.8 3 20 -58.0 0 0 3 50 -55.6 3 100 -53.8 • a>_aaaa�aa>•aaa>•a>•a�a�a>• a>•��a>•a�aa>• aa>•a>_aw��aa>•aa>• , . • al•alalala1a1a1alaal��er a>•�a�aa>_�a>•�aa� �a1� a>_aaaa>•a>•a>_aa�s,aaw�a� a>_a>_a>•aaw�a��aa>•� � a>• aa>• a>• a1� a� aa>• �a>•aa�aa�aw��aa>•a>_a>• � a>. aaa� aa>• a>• aa� aa>• a>_aaaa�a>•a>_��aa>•� �aa�aa>•a�a�aa>•� i aaaa>_aa>• a>• a>• aa� a� aa>• � ��aaa>•aa>•a>.aa�a� i alaaaaraaaa� a>• �aa� s, aa>• a. • • ann>•aa�� Q siaal•aa1 a>•�a>. � -�•��al•al•aaa�aal , �� aa>• aa>_ aa� a>• aa>• a>• -al•��aal�aaal .7 A A50- 0.641Ibrrwte Dewy VM) NOTES: Adjustment Factor for Building Height and Exposurek MEAN ROOF height(fee) EXPOSURE B 15 1 1 21 20 1 1 29 25 1 1 35 30 1 1 40 35 1 5 1 45 40 1 9 1 49 45 112 153 50 116 1 56 55 1 119 1 59 60 1 1 2 1162 -IG N YY r.1- MIr M .eF� M Mlw NwIA wl 1. Fastners to Comply W/ 2017 FBC, 6th Edition, CHAPTER 5 Requirements for 140 mph winds. 2. Shaded area of Trusses Denotes Roof Sheating Diaphrom Fastner Requirement 0 Gable Ends 3. Refer to Gableend Section in Refernce to Diophram 4. All Connections From Fig. to Lintel to be in Compliance with FBC Section 1609 Requirements 5. Drawings Are Not to be Scaled 6. Contractor is Responsible For any Discrepencies in Drawings 7. If Lumber Shows Signs of Cracking When Nailing, Pre Drill For Nails or Use Self Tapping Fastners. 8. Contractor to Use The Greater of Loads of the Truss Manufacture's Colculactions or the Loads on These Drawings Calculated by the Engineer. 9. Structural Details and Plans Are For New Construction Only. These Plans Do Not Update Existing Conditions of The Existing Structure. Therefore Signing And Sealing of These Plans Are Restricted to New Construction. 10. Category II 11. Wind Exposue C, Low Rise Bulidings 12. Internal Pressure Coefficent GCpi = t0.18 13. Components do padding: Design With A Velocity Pressure qh based On Highest Wind Loads 0 The Site p=q(GCp)-gi(Gpi) (#/ft') 14. PANEL EDGE SUPPORT FOR NARROW WIDTH ROOF SHEATHING: For panels 16-24' wide, double ftlip the side adjacent to the full width of the panel, none required at ridge or hip. For Panels 12-16' wide, lumber only blocking (2x4) flat wise or edgewise on the side adjacent to the full width panel. None is required at a ridge or hip. For panels 12 wide or less, lumber only blocking (2x4) flat wise or edgewise on both panel edges. --1 10 20 30 100 200 wo 1000 UMTIVE NIND N"ft* WALL COEFFICIENTS, COMPONENTS & CLADDING (Enclosed Bulldincis) END ZONE NAILING AREAS N.T.S. ELT'rolzwlLol;lim'•• MAIN WIND FORCE LOADING DIAGRAM 00 IF325CWM FWA DFWA D62 SIKCRMDEM BY: FEELITA ENGINEERING RUSSELL FERUTA P.E./ 47075 4221 N. Florida Ave. PHONE (eA�� 500 ENGINEERING r9ner e: SWLP own By. Scale: LP See Plan ad By. Project No. RAF WIND CHARTS I REVISION I w z�$tli IrAf.Cc�+�T�d" �z�2aQYL �a �f}aoR Wall