Loading...
HomeMy WebLinkAbout5440 Gall Blvd (2)3 GENERAL NOTES 1. ALL ARCHITECTURAL, STRUCTURAL, ELECTRICAL, MECHANICAL, AND PLUMBING WORK SHALL BE PERFORMED IN STRICT ACCORDANCE WITH ALL APPLICABLE NATIONAL AND LOCAL CODES AND ORDINANCES, WHETHER LISTED HEREIN OR NOT. 2. ANY & ALL GOVERNING LOCAL LABOR LAWS, REGULATIONS & REQUIREMENTS AND THOSE SET AS BUILDING REQUIREMENTS SHALL BE OBSERVED & FOLLOWED AS THEY RELATE TO THIS PROJECT. 3. CONTRACTOR SHALL OBTAIN ALL REQUIRED BUILDING PERMITS AND CERTIFICATE OF OCCUPANCY PERMIT AS WELL AS SEPARATE MECHANICAL, ELECTRICAL, AND PLUMBING PERMITS PRIOR TO AND DURING CONSTRUCTION. 4. MATERIALS, DIMENSIONS, AND OTHER CONDITIONS NOT OTHERWISE INDICATED IN THESE DRAWINGS SHALL BE ASSUMED AS HAVING THE SAME MEANING AS THOSE ALL WORK SHALL COMPLY WITH MOST SIMILARLY DETAILED AND MORE FULLY DEFINED ELSEWHERE IN THE DRAWINGS. NFFA CODES AND STANDARDS CONTRACTOR TO VERIFY W/ ENGINEER IN WRITING. 5. THE EXTENT OF WORK SHALL BE LIMITED TO THAT INDICATED IN THE CONTRACT DOCUMENTS. NO ADDITIONAL WORK SHALL BE DONE WITHOUT WRITTEN APPROVAL OWNER. ANY ADDITIONAL WORK PERFORMED WITHOUT PRIOR WRITTEN AP 5440 GALL BLVD, ZEPHYRHILLS,.FL 33542 APPROVAL BY OWNER SHALL BE AT THE CONTRACTOR'S EXPENSE. 6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD MEASURING OF EXISTING REVIEW DATE CONDITIONS PRIOR TO START OF WORK & DURING CONSTRUCTION AS NECESSARY CITY OF ZEPHYRHILLS / TO ASSURE CONSTRUCTION ADHERENCE TO DRAWINGS. BY ENTERING INTO A FIRE AND LIFE SAFETY EXAMINER CONSTRUCTION CONTRACT FOR THIS WORK, GC SHALL INDICATE HIS FAMILIARITY WITH THE SITE/FIELD CONDITIONS. PLANS FOR PERMIT & CONSTRUCTION 7. FLOOR TOLERANCE: INLAYING OUT THE WORK TO BE COMPLETED, CONSIDERATION SHALL BE GIVEN TO VARIATIONS IN THE FLOOR LEVEL RESULTING FROM THE CONSTRUCTION QUALITY AND LIVE AND DEAD LOADS IMPOSED ON THE STRUCTURE. FIELD VERIFICATIONS SHALL BE MADE OF CONDITIONS TO VERIFY CONSTRUCTION TOLERANCES AND ALIGNMENT OF DOOR HEADS. OTHER 1 KEY PLAN SCALE: N.T.S. 2 LOCATION MAP SCALE: N.T.S. HORIZONTAL ELEMENTS SHALL BE MAINTAINED AT CONSTANT LEVEL AND SHALL NOT FOLLOW VARIATIONS IN FLOOR PLANE. LEVEL FLOORS AS REQUIRED BY USING AN ��yy y$5¢ y APPROVED LEVELING COMPOUND. " ` F Wge 8. THE CONTRACTOR SHALL BE RESPONSIBLE FOR TAKING ADEQUATE PRECAUTIONS - _. TO PROTECT BUILDING OCCUPANTS, MATERIALS, &EXISTING FINISHES THROUGHOUT � _ _•,,. _'<; ' '_ = ~ _ k " , , ALL PHASES OF CONSTRUCTION. NOISE, SECURITY AND DUST BARRIERS BETWEEN R'•', r,= -v -,'.., - _ ' "_ems :.: ., ,v.-." ,...,, , T' _]•,. - CONSTRUCTION AREAS AND OCCUPIED AND PUBLIC AREAS SHALL BE MAINTAINED _1 , YBY CONTRACTOR. r � OAKS 9. THE GC SHALL BE RESPONSIBLE FOR MAINTAINING BUILDING CORRIDORS CLEAR�H t: 111 x . rt'�� s � ,�, r -tea'- � ;, , - ` : <5i►� OF PROJECT MATERIALS AND EQUIPMENT. r4.-. La r i� c: •? e. r v rkTi - x 10. GC SHALL PROVIDE GENERAL CARPENTRY AS REQUIRED FOR WORK WHICH MAY �_, .• x WORK AREA phyrhi k .. , NOT FALL UNDER THE JURISDICTION OF A SPECIFIED TRADE BUT IS REQUIRED FOR6i t „s v., 0 PROPER JOB EXECUTION AND COMPLETION OF CONSTRUCTION. - 39,8 t 58 r: Tx 11. NO MODIFICATIONS/REVISIONS/CHANGES SHALL BE UNDERTAKEN UNLESS SPECIFICALLY SO INSTRUCTED & APPROVED BY CLIENT.;~ 12. CONTRACTOR IS RESPONSIBLE FOR CHECKING ALL CONTRACT DOCUMENTS, FIELD CONDITIONS AND DIMENSIONS FOR ACCURACY AND CONFIRMING THAT of LIVE OK v PRESERVE WORK IS BUILDABLE AS SHOWN BEFORE PROCEEDING WITH CONSTRUCTION. IF THERE s Kevstone l ARE ANY QUESTIONS, THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING ALake Fern Cheval j Peoble Creek Hilisbo ugh F� , CLARIFICATION FROM THE ENGINEER BEFORE PROCEEDING WITH WORK IN i a 4' i i f QUESTION. ., ., � .. '.§. r. f E ' �. �.. � " , w,, , , ' .;ARBOR,CIE_Sta 13. THE INTENT OF THE CONTRACT DOCUMENTS IS TO EXCLUDE ALL MATERIALS WHICH �, s,' a �i 9 I . Il , �i l CONTAIN KNOWN HAZARDOUS SUBSTANCES. THESE INCLUDE MATERIALS w CONTAINING ASBESTOS, POLYCHLORINATED BIPHENYL PCB , OR ANY OTHER KNOWN r•A, ~` 1 NEVr AMPA SUBSTANCES DETERMINED TO BE A HEALTH HAZARD BY THE UNITED STATES �; �_.- -- Ore .; 1� k �a T MP Northdale ENVIRONMENTAL PROTECTION AGENCY (EPA) AND OTHER RECOGNIZED AGENCIES.° " PALMS � IN STUDYING THE CONTRACT DOCUMENTS, AND AT ANY TIME DURING EXECUTION OF r: THE WORK, THE CONTRACTOR SHALL AT ONCE REPORT TO THE ENGINEER ANY : =, , is AT HE/SHE DISCOVER. D ,f. � �.. �,. - � , �; ��, � � ,_ MATERIALS CONTAINING HAZARDOUS SUBSTANCES TH HE/S ISCO O 1 it NOT PROCEED WITH INSTALLATION OF HAZARDOUS MATERIALS. = cyx _ r. -= �.. � � W K AREA �. � � OR Y 14. CONTRACTOR SHALL VERIFY PRESENCE OF HAZARDOUS MATERIALS WITH OWNER .r.- .� - _.:^ ,: "= . �,".. , ,. ,�-, . � ;. � f ,� �T .: t I I I) ., :.Greater ENGINEER AND ITS CONSULTANTS SHALL HAVE NO RESPONSIBILITY FOR THE EE��+x �`¢� l#{ qq//}}y/RR ?44: ,:.. Fyn -_Y. , „'':. �. -• .f `''^t 4.r1 TTad I elY'tJ W DISCOVERY PRESENCE HANDLING REMOVAL OR DISPOSAL OF OR EXPOSURE OF y -' r Y 584 .., .. . 4: PERSONS TO HAZARDOUS MATERIALS IN ANY FORM AT THE PROJECT SITE INCLUDINGT � .T _• � .�: -: •�-"z-_< , - i � = :. N � a I T LIMITED T ASBESTOS, P LYCHL RINA ED BIPHENYL PCB OR OTHER TOXIC BUT NO LIM D O, O O T BIPHENYL(PCB) _,f - _. _ . SUBSTANCES. .,.. .: ,.� w. , .., �_ , �.. E t f�. - FE STANDARD OR DESCRIPTIVE : , __ ". �., _ T T► . 15. WHERE PRODUCTS ARE SPECIFIED BY REFERENCE STA A O ESC M _.,. ._ - _ tI R � CountryMANNER WITHOUT MANUFACTURERS NAME MODEL NUMBER OR TRADE NAME - CONTRACTOR SHALL SELECT MATERIALS MEETING SPECIFIED REQUIREMENTS WHICH w :r• wyrY WSUBSTANCESI NY F RM AND SUBMIT DO NOT CONTAIN KNOWN HAZARDOUS N A O SU M O .,,. .�. �, ,_ r _ >< .� a-. Hope ARCHITECT FOR APPROVAL. �-. � _., �. � �.,:. .� .,, �, _ : _ � _ .. s AND EQUIPMENT IN STRICT 16. INSTALL ALL MANUFACTURED ITEMS, MATERIALS N EQU S C ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDED SPECIFICATIONS _ _ -� � _� , _ � - .: , , - j -�, •�,.�,_ , , I _ _mot. ._ - .:<• ._, f _ P EXCEPT THAT THE SPECIFICATIONS HEREIN HERE MORE STRINGENT,SHALL BE . -�.. v ..� - . ioo .. a COMPLIED WITH. z;. valoco _ e 17. IN MAKING REQUESTS FOR SUBSTITUTION, CONTRACTOR SHALL BE RESPONSIBLE ..: .�.H . . , . t,-• �. :.. � � , . .,, .. s _ - 6i FOR DETERMINING THAT MATERIALS REQUESTED FOR SUBSTITUTION ARE FREE OF ." , . � _, .�, _ -_, � . . , � � _ _. :� ,,.. �. �.- t ", ,.- s. t. -. . -� .. = �. _ _ , TAPS, _ .,. �. _„ a,Hop KNOWN HAZARDOUS SUBSTANCES IN ANY FORM. � r ... ....,� , ....,, r _ r .: „ ., � .,,�:, .,,, , .. , KITCHEN EXPANSION AT EXISTING HUNGRY HOWIES µ Palm 18. FIRE RATED PARTITIONS SHALL BE NOTED IN STENCIL ABOVE FINISHED CEILING PER e1 APPLICABLE CODE. h,.Durant 4 APPLICABLE CODES 5 ARCHITECTURAL SYMBOLS 6 INDEX OF DRAWINGS 7 BUILDING INFORMATION 8 PROJECT SCOPE ROOM BUILDING CODE: FLORIDA BUILDING CODE FDED ROOM NAME & NUMBER 8TH EDITION (2023) BUILDING PARTITION WALL TYPE EXISTING BUILDING CODE: FLORIDA BUILDING CODE 8TH EDITION (2023) EXISTING BUILDING D.XX DOOR TYPE ENERGY CODE: FLORIDA BUILDING CODE �/_X WINDOW TYPE 8TH EDITION (2023) ENERGY CONSERVATION MECHANICAL CODE: FLORIDA BUILDING CODE 1 ## EQUIPMENT TYPE 8TH EDITION (2023) MECHANICAL PAGE NOTES PLUMBING CODE: FLORIDA BUILDING CODE 8TH EDITION (2023) PLUMBING 1 REVISION NUMBER FUEL GAS CODE: FLORIDA BUILDING CODE 8TH EDITION (2023) FUEL GAS P-2 WALL ACCESSIBILITY CODE: FLORIDA BUILDING CODE BASE B-j FINISH SCHEDULE 8TH EDITION (2023) ACCESSIBILITY FLOOR VCT-2 LIFE SAFETY & FIRE CODE: FLORIDA FIRE PREVENTION CODE 8TH EDITION (2023) Xi SHT ELEVATION ELECTRICAL CODE: NFPA 70 (2020) NATIONAL ELECTRICAL CODE X DETAIL TAG SHT ARCHITECTURAL DRAWINGS A0.1 COVER SHEET A I A LIFE SAFETY PLAN A1.2 EXISTING & DEMOLITION FLOOR PLAN A1.3 PROPOSED FLOOR PLAN A1.4 REFLECTED CEILING PLAN A1.5 FINISH & EQUIPMENT PLAN A2.1 DOOR, WINDOW, AND WALL DETAILS PLUMBING DRAWINGS P0.1 PLUMBING NOTES & SCHEDULE PIA PLUMBING WATER PLAN P1.2 PLUMBING SANITARY PLAN P1.3 PLUMBING GAS PLAN MECHANICAL DRAWINGS M0.1 MECHANICAL NOTES & SCHEDULE M1.1 EXISTING MECHANICAL PLAN M1.2 PROPOSED MECHANICAL PLAN M1.3 MECHANICAL ROOF PLAN & DETAILS ELECTRICAL DRAWINGS E0.1 ELECTRICAL NOTES & SCHEDULE E1.1 ELECTRICAL LIGHTING PLAN E1.2 ELECTRICAL POWER PLAN E2.1 ELECTRICAL PANEL & DETAILS STRUCTURAL DRAWINGS S0.1 STRUCTURAL NOTES & DETAILS BUILDING ADDRESS: 5440 GALL BOULEVARD, INTERIOR RENOVATIONS AT AN EXISTING HUNGRY HOWIES RESTAURANT. ZEPHYRHILLS, FL 33542 CONVERT EXISTING SEATING AREA TO AN ADDITIONAL KITCHEN AND PREPARATION AREA. BUILDING TO BE USED AS TAKE OUT ONLY AND WILL JURISDICTION: PASCO COUNTY / CITY OF ZEPHYRHILLS HAVE NO INTERIOR DINING AREA. PARCEL ID: 11-26-21-0010-13200-0270 OCCUPANCY TYPE: BUSINESS (B) CONSTRUCTION TYPE: II-B TYPE OF WORK: INTERIOR RENOVATIONS ALL WORK SHALL COMPLY WITH PREVAILING PROJECT AREA: 3,131 SQ.FT. COVES FLORIDA BUILDING CODE, NATIONAL ELECTRIC CODE, FIRE PROTECTION: FIRE EXTINGUISHER AND THE CITY OF ZEPHYRHILLS NON -SPRINKLED ORDINANCES NUMBER OF STORIES: ONE BUILDING HEIGHT: MAX 25' / REVIEW DATE: CITY OF ZEPW BUILDING OFFS ENGINEERING & CONSTRUCTION AUSTIN CONSTRUCTION GROUP 2706 STALLONE DRIVE TAMPA, FLORIDA 33605 (813) 293-8883 FLORIDA PE 48917192169 - CGC1521407 - CUC1224196 - CFC 1430334 - FPC 15-4000052 PROJECT INFORMATION: CLIENT: RICHARD KAZBOUR PROJECT NAME: HUNGRY HOWIES RESTAURANT ADDITION PROJECT LOCATION: 5440 GALL BLVD ZEPHYRHILLS, FL 33542 SEAL: AT51 lei `�`J f.`G N g `•� 110 • w • W = �K OF Lu .; S ram` �� •• ��Ci `�� ��i ASS IOc1P �� Ilt FL COA NO. 30178 ENGINEER OF RECORD FL LICENSE NO. TO THE BEST OF THE ENGINEER'S KNOWLEDGE, THE PLANS AND SPECIFICATIONS COMPLY WITH THE APPLICABLE MINIMUM BUILDING CODES REVISIONS: NO. DATE COMMENTS SHEET TITLE: COVER SHEET SHEET INFORMATION: DRAWN: A.C. SHEET NO. DATE: 7/22/2024 CHECKED: K.C. DATE: 7/22/2024 AO* PROJECT NUMBER: SCALE: INDEX: AS SHOWN 1 1 LIFE SAFETY PLAN SCALE:3/16''=1'-0" 1 2 1 CODE CLASSIFICATION AND REQUIREMENTS: OCCUPANCY CLASSIFICATION B - BUSINESS CONSTRUCTION TYPE II-B BUILDING AREA 3,131 S.F. AUTOMATIC SPRINKLER SYSTEM NO FIRE -RESISTANCE RATING FOR BLINDING PRIMARY STRUCTURAL FRAME: 0 HRS ELEMENTS (HRS) NONBEARING WALL AND PARTITIONS EXTERIOR: 0 HR FIRE-RESISTANT SEPARATION (HRS) 0 HR REQUIRED 0 HR PROVIDED MAXIMUM AREA OF EXTERIOR WALL OPENINGS BASED ON FIRE SEPARATION NO LIMIT DISTANCE AND DEGREE OF OPENING PROTECTION OCCUPANT LOAD 12 OCCUPANTS, SEE TABLE MINIMUM REQUIREMENT EGRESS WIDTH REQUIRED = 17 * 0.2" = 3.4" PROVIDED = 34'' * 4 = 136'' MINIMUM REQUIREMENT OF EXISTS FOR REQUIRED = 2 EGRESS PROVIDED = 4 FIRE EXTINGUISHER HAZARD OCCUPANCY INDUSTRIAL GENERAL PURPOSE (ORDINARY HAZARD) MINIMUM RATED SINGLE EXTINGUISHER: A,B,C - 10 MAXIMUM FLOOR AREA FOR FIRE PROTECTION SYSTEM EXTINGUISHER: 11,250 SF NUMBER OF EXTINGUISHERS PROVIDED = 5 EXTINGUISHERS MAXIMUM TRAVEL DISTANCE TO EXTINGUISHER = > 75-0" 3 OCCUPANT LOAD CALCULATIONS: OCCUPANT LOAD CALCULATIONS TYPE AREA / NO. DESCRIPTION COUNT KITCHEN/PREP AREA 2,851 S.F. 200 SF PER PERSON 14.26 BUSINESS/SERVING 280 150 SF PER PERSON 1.87 TOTAL 3,131 S.F. 17 4 1 NOTES - ALL EXIT CORRIDORS AND HALLWAYS ARE TO BE PROVIDED WITH A MINIMUM OF 1-1/2" HOURS OF EMERGENCY LIGHTING. LIGHTING FACILITIES SHALL BE ARRANGED TO PROVIDE INITIAL ILLUMINATION THAT IS NOT LESS THAN THE AVERAGE OF 1 FT -CANDLE AND, AT ANY POINT, NOT LESS THAN 0.1 FOOT CANDLE, MEASURED ALONG THE PATH OF EGRESS AT FLOOR LEVEL. REFERENCE SECTION 7.9.2 NFPA 101 (2021 EDITION) ALL EMERGENCY LIGHTS AND EXIT SIGNS TO BE EQUIPPED WITH APPROVED BATTERY BACKUP - FIRE EXTINGUISHERS SIZE, TYPE AND LOCATIONS TO MEET NFPA 10 (2022 ED.) AND NFPA 30A (2021 ED.). 5 1 MEANS OF EGRESS REQUIREMENTS: UN -SPRINKLED PROVIDED MAX. COMMON PATH OF TRAVEL 75-0" 22'-0" MAX. DEAD END CORRIDOR 20'-0'' N/A MAX. TRAVEL DISTANCE TO EXIT 75-0" 27 4' NUMBER OF EXITS PER STORY N/A N/A MIN. EXIT SEPARATION 1 /2 DIAG. DIST = 36-5" 41 2" MIN. WIDTH OF EGRESS STAIRS 44'-0'' N/A NUMBER OF EXITS FOR OCCUPANT LOAD 2 3 EGRESS STAIR WIDTH/PERSON 0.3''/OCCUP N/A EGRESS COMPONENT WIDTH/PERSON 0.2" /OCCUP < MIN. REQ'D 1 6 1 INTERIOR FINISH REQUIREMENTS: l . FINISH REQUIREMENTS / OCCUPANCY: FBC TABLE 803.11 (UNSPRINKLED) 2. EXITS: CLASS -A, FLAME SPREAD 01-26; SMOKE DEVELOPED 0-450 3. EXITS ACCESS: CLASS-B, FLAME SPREAD 26-75; SMOKE DEVELOPED 0-450 4. OTHER SPACES: CLASS-C, FLAME SPREAD 76-200; SMOKE DEVELOPED 0-450 7 1 LIFE SAFETY LEGEND: SYMBOL DESCRIPTION MOUNTING/REMARKS FE 1 FIRE EXTINGUISHER WALL MOUNTED TYPE A,B,C -10 FE 2 FIRE EXTINGUISHER WALL MOUNTED TYPE 1-A : K MOUNTED ABOVE EXIT DOORS EXIT EMERGENCY EXIT SIGN W/ 90 MIN. BACKUP (TYP.) W/ LIGHT *UPGRADE AS REQUIRED* E_X_l TI EXIT SIGN CEILING MOUNTED W/ 90 MIN. BACKUP (TYP.) ----- COMMON PATH OF TRAVEL - - - - - - - MAX TRAVEL DISTANCE POINT OF DECISION (COMMON PATH) 1 8 1 ACCESSIBLE EXTINGUISHER: BRACKET MOUNTED FIRE EXTINGUISHER r\ N ACCESSIBLE EXTINGUISHER NOTE: FIRE EXTINGUISHERS TO MEET OR EXCEED THE LATEST NFPA 10 CODE. o �s ENGINEERING & CONSTRUCTION AUSTIN CONSTRUCTION GROUP 2706 STALLONE DRIVE TAMPA, FLORIDA 33605 (813) 293-8883 FLORIDA PE 48917 1 92169 - CGC 1521407 - CUC 1224196 - CFC 1430334 - FPC 15-4000052 PROJECT INFORMATION: CLIENT: RICHARD KAZBOUR PROJECT NAME: HUNGRY HOWIES RESTAURANT ADDITION PROJECT LOCATION: 5440 GALL BLVD ZEPHYRHILLS, FL 33542 SEAL: COATS,��`fffs e • N • e LU Cr Sl FL COA NO. 30178 ENGINEER OF RECORD FL LICENSE NO. TO THE BEST OF THE ENGINEER'S KNOWLEDGE, THE PLANS AND SPECIFICATIONS COMPLY WITH THE APPLICABLE MINIMUM BUILDING CODES REVISIONS: NO. DATE COMMENTS SHEET TITLE: LIFE SAFETY SHEET INFORMATION: DRAWN: A.C. SHEET NO. DATE: 7/22/2024 CHECKED: K.C. Alol DATE: 7/22/2024 PROJECT NUMBER: SCALE: INDEX: AS SHOWN I I EXISTING & DEMOLITION FLOOR PLAN SCALE: 1/4"=1'-0° 1 2 1 PAGE KEY NOTES MARK NOTES 1 BEVERAGE AREA TO BE REMOVED. 2 CUT COUNTERTOP AT CUSTOMER SERVICES AREA FOR NEW OPENING. 3 REMOVE AND REPLACE EXISTING STOREFRONT SECTION. SEE PROPOSED FLOOR PLAN. 4 - 5 - 6 7 - 8 - 9 - 1 3 1 WALL LEGEND <#> MARK NOTES 1 EXITING CMU WALLS WITH 3-5/8" STUD AND 5/8" GYP. BOARD. 2 EXISTING KNEE WALL 3 EXISTING INTERIOR PARTITION WALL 4 EXISTING WALK-IN FREEZER WALL ` . ` + + " om. t 5 NEW INTERIOR PARTITION WALL 3-5/8" 20GA. METAL STUDS 16" O.C. W/ 5/8" GYPSUM BOARD EACH SIDE 6 NEW WALK-IN FREEZER WALL BY MANUFACTURER. 7 - NOTE: USE MOISTURE RESISTANCE BOARD IN WET AREAS 4 1 DEMOLITION NOTES 1. THE CONTRACTOR TO FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO COMMENCING ANY WORK ON THE STRUCTURE. 2. THE CONTRACTOR IS TO ACCEPT FULL RESPONSIBILITY FOR THE STABILITY AND STRUCTURAL INTEGRITY OF THE EXISTING STRUCTURES WITHIN AND ADJACENT TO THE WORKS. 3. THE CONTRACTOR SHALL SUBMIT, AND HAVE AGREED WITH THE ENGINEER, HIS PROPOSALS FOR TEMPORARY SUPPORTS AD METHOD OF WORKING. THESE ARE TO INCLUDE ALL NECESSARY CALCULATIONS IF REQUIRED. 4. THE CONTRACTOR IS TO CARRY OUT ALL AGREED PROPPING TO WALLS AND FLOORS PRIOR TO THE REMOVAL OF ANY WALLS. 5. NO VARIATION IN THE STRUCTURAL DETAILS SHOWN ON THESE DRAWINGS WILL BE PERMITTED WITHOUT THE WRITTEN APPROVAL OF THE ENGINEER. ENGINEERING & CONSTRUCTION AUSTIN CONSTRUCTION GROUP 2706 STALLONE DRIVE TAMPA, FLORIDA 33605 (813) 293-8883 FLORIDA PE 48917 192169 - CGC 1521407 - CUC 1224196 - C F C 1430334 - F P C 15-4000052 PROJECT INFORMATION: CLIENT: RICHARD KAZBOUR PROJECT NAME: HUNGRY HOWIES RESTAURANT ADDITION PROJECT LOCATION: 5440 GALL BLVD ZEPHYRHILLS, FL 33542 SEAL: �r�ru�rrur r� 0AT S ••.� ''. NS E .. • FLO ` FL COA NO. 30178 ENGINEER OF RECORD FL LICENSE NO. TO THE BEST OF THE ENGINEER'S KNOWLEDGE, THE PLANS AND SPECIFICATIONS COMPLY WITH THE APPLICABLE MINIMUM BUILDING CODES REVISIONS: NO. DATE COMMENTS SHEET TITLE: EXISTING& DEMOLITION FLOOR PLAN SHEET INFORMATION: DRAWN: A.C. SHEET NO. DATE: 7/22/2024 CHECKED: K.C. DATE: 7/22/2024 A1,2 PROJECT NUMBER: SCALE: INDEX: AS SHOWN IN 1 I PROPOSED FLOOR PLAN SCALE: 1/4''= Y-0'' 1 2 1 PAGE KEY NOTES MARK NOTES 1 SHADED AREA IS OUT OF SCOPE OF WORK. APPROXIMATE LOCATION OF KITCHEN AND PREP AREA EQUIPMENT. 2 CONTRACTOR TO COORDINATE EXACT LOCATION IN FIELD WITH OWNER PRIOR TO INSTALLATION. 4"X4" HSS COLUMN FOR ROOF TOP LOAD. CONTRACTOR TO COORDINATE 3 EXACT LOCATION IN FIELD WITH CAPTIEVAIRE TO VERIFY LOCATION IS UNDER MUA-1 UNIT FOR NEW POINT LOAD ADDED TO ROOF. SEE STRUCTURAL PLAN FOR DETAILS. CONTRACTOR TO ADD OSHA COMPLIANT ROOF ACCESS LADDER WITH WITH CAGED WALKTHROUGH. CONTRACTOR TO FIELD VERIFY EXACT LOCATION IN 4 FIELD WITH OWNER AND HEIGHT OF BUILDING FOR LADDER HEIGHT REQUIREMENTS. CONTRACTOR TO PATCH EXISTING DAMAGED DRYWALL AT REAR OF 5 BUILDING. CONTRACTOR TO COORDINATE SCOPE AND COST WITH OWNER PRIOR TO FINALIZATION OF BID. 6 WALK-IN COOLER SUPPLIED BY OWNER AND INSTALLED BY GENERAL CONTRACTOR. CONTRACTOR TOO COORDINATE WITH OWNER. 7 - 8 - 9 - 1 3 1 WALL LEGEND <#> MARK NOTES 1 EXITING CMU WALLS WITH 3-5/8"STUD AND 5/8" GYP. BOARD. 1 2 EXISTING KNEE WALL 3 EXISTING INTERIOR PARTITION WALL 4 EXISTING WALK-IN FREEZER WALL + + + + + + + + + + 5 NEW INTERIOR PARTITION WALL 3-5/8" 20GA. METAL STUDS 16'' O.C. W/ 5/8" GYPSUM BOARD EACH SIDE 6 NEW WALK-IN FREEZER WALL BYE„t> MANUFACTURER. (RELOCATED UNIT)` 7 NEW INTERIOR KNEE WALL - 38" MAX. HT. 3-5/8'' 20GA. METAL STUDS 16" O.C. W/ 5/8" GYPSUM BOARD & FRP FULL HEIGHT NOTE: USE MOISTURE RESISTANCE BOARD IN WET AREAS 4 GENERAL FLOOR PLAN NOTES 1. GC MAY SUBSTITUTE ANY MANUFACTURER W/ AN EQUIVALENT. ALL SUBSTITUTIONS TO BE APPROVED BY THE OWNER. 2. ALL DIMENSIONS AND CONDITIONS SHOULD BE FIELD VERIFIED. THE ENGINEER SHOULD BE NOTIFIED OF ALL ERRORS, INCONSISTENCIES OR OTHER PROBLEMS IMMEDIATELY UPON DISCOVERY AND BEFORE PROCEEDING WITH THE WORK. 3. DIMENSIONS ARE TAKEN FROM FACE OF STUD AND COLUMN CENTER LINES UNLESS NOTED OTHERWISE. CLEAR DIMENSIONS ARE TO FINISHED FACE OF CONSTRUCTION AND SHALL TAKE PRECEDENCE OVER ANY OTHER DIMENSIONS. 4. GYPSUM BOARD SHALL HAVE CONTROL JOINTS AT 30'-0'' O.C. ENGINEERING & CONSTRUCTION AUSTIN CONSTRUCTION GROUP 2706 STALLONE DRIVE TAMPA, FLORIDA 33605 (813) 293-8883 FLORIDA PE 48917 192169 - CGC1521407 - CUC1224196 - CFC 1430334 - FPC 15-4000052 PROJECT INFORMATION: CLIENT: RICHARD KAZBOUR PROJECT NAME: HUNGRY HOWIES RESTAURANT ADDITION PROJECT LOCATION: 5440 GALL BLVD ZEPHYRHILLS, FL 33542 SEAL: G®ATS �• .�� �G 69 _ • 1p* • w 4 • s a V a• !` . U a• sly„ �)% ••4s ea ea•• � 0� FL COA NO. 30178 ENGINEER OF RECORD FL LICENSE NO. TO THE BEST OF THE ENGINEER'S KNOWLEDGE, THE PLANS AND SPECIFICATIONS COMPLY WITH THE APPLICABLE MINIMUM BUILDING CODES REVISIONS: NO. DATE COMMENTS SHEET TITLE: PROPOSED FLOOR PLAN SHEET INFORMATION: DRAWN: A.C. SHEET NO. DATE: 7/22/2024 CHECKED: K.C. DATE: 7/22/2024 A1.3 PROJECT NUMBER: SCALE: INDEX: AS SHOWN I I PROPOSED FLOOR PLAN SCALE :I/4"=,'-0" 1 2 1 PAGE KEY NOTES RI I MARK NOTES 1 SHADED AREA IS OUT OF SCOPE OF WORK. 2 EXISTING CEILING IN AREA TO REMAIN. 3 CUT HEADER OVER CUSTOMER SERVICE AREA 6" BELOW EXISTING CEILING GRID THE ENTIRE SERVICE BAR AREA. 4 CEILING IN WALK-IN COOLER BY MANUFACTURER. 5 CHANGE EXISTING 2X2 CEILING TILES PER LEGEND (TYP.). NOTE: CONTRACTOR TO PROVIDE OPTION TO OWNER TO PAINT EXISTING CEILING GRID WHITE. 6 FOR CEILING LIGHT INFORMATION, SEE ELECTRICAL LIGHT PLAN ON SHEET El .l (TYP.) 7 - 8 - 9 - 3 � WALL LEGEND EXISTING 2' x 2' CEILING TILE TO REMAIN. EXISTING 2' x 2' ACOUSTICAL CEILING GRID. REPLACE EXISTING TILES WITH DURACLEAN SMOOTH WHITE TILES (FOOD GRADE & FIRE RATED). Ell EXISTING 2 x 2 LED RECESSED LIGHT FIXTURE OQ EXISTING LED CAN LIGHT FIXTURE EXISTING 2 X 2 LED RECESSED LIGHT FIXTURE TO BE REMOVED. HT. CEILING HEIGHT TAG FROM FFE ENGINEERING & CONSTRUCTION AUSTIN CONSTRUCTION GROUP 2706 STALLONE DRIVE TAMPA, FLORIDA 33605 (813) 293-8883 FLORIDA PE 48917 192169 - CGC 1521407 - CUC 1224196 - CFC 1430334 - FPC 15-4000052 PROJECT INFORMATION: CLIENT: RICHARD KAZBOUR PROJECT NAME: HUNGRY HOWIES RESTAURANT ADDITION PROJECT LOCATION: 5440 GALL BLVD ZEPHYRHILLS, FL 33542 SEAL: \GOATS �I �N\ ••Neeee• � .•GIN S E •'•• �c `'. • � i•V ��g • s 4L • sL.0 1 of FL COA NO. 30178 ENGINEER OF RECORD FL LICENSE NO. TO THE BEST OF THE ENGINEER'S KNOWLEDGE, THE PLANS AND SPECIFICATIONS COMPLY WITH THE APPLICABLE MINIMUM BUILDING CODES REVISIONS: NO. DATE COMMENTS SHEET TITLE: PROPOSED CEILING PLAN SHEET INFORMATION: DRAWN: A.C. SHEET NO. DATE: 7/22/2024 CHECKED: K.C. DATE: 7/22/2024 Al • 4 PROJECT NUMBER: SCALE: INDEX: AS SHOWN I FINISH & EQUIPMENT PLAN SCALE: 1/4''=1'-0° 1 2 1 PAGE KEY NOTES MARK NOTES 1 SHADED AREA IS OUT OF SCOPE OF WORK. 2 - 3 - 4 - 5 - 6 - 7 - 8 - 9 - 4 1 FINISH SCHEDULE SYMBOL MATERIAL REMARKS WALL W-1 PAINT SHERWIN WILLIAMS - COLOR SELECTED BY OWNER W-2 FRP FRP PANELS IN KITCHEN AREA INSTALLED FULL HEIGHT W-3 STAINLESS STAINLESS STEEL BACKSPLASH UNDER HOOD AREA W-4 TILE EXISTING SERVICE COUNTER: SUBWAY TILE FINISH TO REMIAN BASE B-1 TILE EXISTING TILE BASE COVE TO REMAIN FLOOR F-1 TILE EXISTING TILE (PATCH AND REPAIR AS NEEDED) 5 1 EQUIPMENT SCHEDULE ### NO QTY MODEL DESCRIPTION 101 6 - NATURAL GAS DEEP FRYER 102 1 - TYPE 1 HOOD BY ECON-AIR 103 1 - ANSUL SYSTEM 104 1 - BREADING STATION 105 2 - 18'' HAND SINK 106 1 - CHEST FREEZER 107 1 - REFRIGERATOR, REACH -IN 108 2 - 72" WORK TABLE 109 1 - REFRIGERATOR, REACH -IN, GLASS DOOR 110 1 - WALK IN COOLER (EXISTING/RELOCATED) 1 1 1 1 - SINK, 3 COMP 96" 112 1 - SINK, 1 COMP 48" 113 1 - PRERINSE FAUCET 114 1 - DRAIN, LEVER HANDLE 115 2 - 36" WALL MOUNTED SHELF ® ®AIIIIIIIIIIIIII� Lff &I ENGINEERING & CONSTRUCTION AUSTIN CONSTRUCTION GROUP 2706 STALLONE DRIVE TAMPA, FLORIDA 33605 (813) 293-8883 FLORIDA PE 48917 192169 - CGC1521407 - CUC1224196 - CFC1430334 - F PC 15-4000052 PROJECT INFORMATION: CLIENT: RICHARD KAZBOUR PROJECT NAME: HUNGRY HOWIES RESTAURANT ADDITION PROJECT LOCATION: 5440 GALL BLVD ZEPHYRHILLS, FL 33542 SEAL: ``011111111111 �, G v ATS .�� 'tN •'• N S E •'•• • GJ ` - _ W FL COA NO. 30178 ENGINEER OF RECORD FL LICENSE NO. TO THE BEST OF THE ENGINEER'S KNOWLEDGE, THE PLANS AND SPECIFICATIONS COMPLY WITH THE APPLICABLE MINIMUM BUILDING CODES REVISIONS: NO. DATE COMMENTS SHEET TITLE: FINISH & EQUIPMENT PLAN SHEET INFORMATION: DRAWN: A.C. SHEET NO. DATE: 7/22/2024 /� CHECKED: K.C. DATE: 7/22/2024 ,�••1�` � • 5 PROJECT NUMBER: SCALE: INDEX: AS SHOWN I I DOOR SCHEDULE 2 1 STOREFRONT SCHEDULE: r.iG\ni ci DOOR NUMBER DOOR TYPE FRAME TYPE PROVIDED BY INSTALLED BY SIZE MATERIAL GLAZING JAMB DETAIL HARDWARE REMARKS DO] EX. EX. EX. EX. EX. EX. EX. EX. EX. EXT. ALUMINUM/GLASS STOREFRONT DOOR TO REMAIN D 02 EX. EX. EX. EX. EX. EX. EX. EX. EX. EXT. ALUMINUM/GLASS STOREFRONT DOOR TO REMAIN D 03 EX. EX. EX. EX. EX. EX. EX. EX. EX. EXISTING INTERIOR DOOR TO REMAIN D 04 EX. EX. EX. EX. EX. EX. EX. EX. EX. EXISTING INTERIOR DOOR TO REMAIN D 05 EX. EX. EX. EX. EX. EX. EX. EX. EX. EXT. ALUMINUM/GLASS STOREFRONT DOOR TO REMAIN MARK PROVIDED BY INSTALLED BY SIZE MATERIAL GLAZING REMARKS w— 1 G.C. G.C. GLASS/ALUMINUM TEMPERED/IMPACT WIN[Dow ON NOTE: STOREFRONT CONTRACTOR TO FIELD MEASURE AND VERIFY WINDOW DIMENSIONS PRIOR TO ANY FABRICATION AND INSTALLATION. SIZES PROVIDED ARE APPROXIMATE. HANDICAP ACCESSIBLE GUIDELINES:4.27.4 OPERATION CONTROLS AND OPERATING MECHANISMS SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST. THE FORCE REQUIRED TO ACTIVATE CONTROLS SHALL BE NO GREATER THAN 5 LBF (22.2 N). 5 KNEE WALL DETAIL 3 1 STOREFRONT NOTES 4 STOREFRONT TYPES STOREFRONT GENERAL NOTES: STONE WALL CAP OR 1. PROVIDE SAFETY GLAZING (TEMPERED) AS REQUIRED BY FLORIDA APPROVED EQUAL BY OWNER BUILDING CODE (FBC) SECTION 2405. 2. CONTRACTOR SHALL PROVIDE FLORIDA PRODUCT APPROVAL SUBMITTALS FOR THE FOLLOWING BUILDING COMPONENTS. 4-12 3-5/8" TOP TRACK 2.1. EXTERIOR HOLLOW METAL DOORS 2.2. STOREFRONT SYSTEMS EXISTING STOREFRONT 3. STOREFRONT ALUMINUM FINISH TO BE CLEAR ANODIZED. TO REMAIN 3-5/8" METAL STUDS 16" O.C. 4. CONTRACTOR TO PROVIDE (3) COPIES FOR REVIEW AND SUBMITTALS TO THE LOCAL JURISDICTION. f- 5/8" GYP BOARD EA. SIDE o MOISTURE RESISTANT FINISHED W/ FRP PANELS 0 CLARKDIETRICH PONY WALL N FINISH BRACING EVERY 48" O.C. FLOOR TYPE W-1(NEW SLIDING WINDOW) 3-5/8" BOTTOM TRACK TAPCON TO EX. CONC. EVERY 12" O.C. F NTERIOR PARTITION WALL TYPE 1 DETAIL 7 INTERIOR PARTITION WALL TYPE 2 DETAIL 8 FRAMING NOTES 9 FLORIDA PRODUCT APPROVAL LIST NOTES: l . FRAMING MATERIALS 1.1. STUDS AND TRACKS: ANSI ASTM C645: GALVANIZED SIZES AND SHAPES AS SHOWN ON THE DRAWINGS. PROVIDE 20 GA. C STUDS (3-5/8") UNLESS NOTED OTHERWISE. 1.2. BACKING: GALVANIZED SHEET METAL, 20 GA. 1.3. FURRING CHANNELS: 20 GA., 7/8" HAT SHAPED FORMED STEEL. STEEL CHANNEL 20 GA. GALV. STEEL CHANNEL 2. GYPSUM BOARD MATERIALS FASTEN 24" O.C. MAX. 2.1. GYPSUM BOARD: ANSI/ASTM C36: FIRE ASSEMBLIES UL RATED: 5/8" THICK, ENDS SQUARE CUT, TAPERED EDGES. D "T I K ND APPROVED PRODUCTS LIST PRODUCT CATEGORY SUB —CATEGORY MANUFACTURER APPROVAL # WINDOW PASS —THROUGH READY ACCESS FL5102.3 2.2. MOISTURE RESISTANT GYPSUM BOAR .ANSI/ASTM C630. 5/8 H C , E S EXTEND WALL TO UNDERSIDE OF SQUARE CUT, TAPERED EDGES. EX. ROOF DECK (OR) INSTALL 2.3. MOISTURE RESISTANT GYPSUM BOARD: ANSI/ASTM C630: 5/8" THICK, ENDS EXTEND WALL TO UNDERSIDE OF KICKERS 5-0" O.C. MAX. SQUARE CUT, TAPERED EDGES. EX. ROOF DECK. NOTE: GWB TO STOP 4'' DROP 3. ACCESSORIES CEILING OR TO UNDERSIDE OF FOR CEILING INFORMATION SEE 3.1. SEALANT: NON -HARDENING PERMANETLY RESILIENT AND NON -SKINNING, FOR ROOF DECK. SEE FLOOR PLAN. RCP USE IN CONJUNCTION WITH GYP BOARD. 3.2. CORNER BEADS: METAL 3.3. JOINT MATERIALS: ANSI/ASTM C475: REINFORCING TAPE, JOINT COMPOUND, ADHESIVE, WATER, FASTENERS. 3.4. TEXTURE MATERIALS: SPRAY APPLIED LIGHT TO MEDIUM FINE TEXTURE. 5/8" GYP. BOARD EA. SIDE. SEE 5/8" GYP. BOARD EA. SIDE. SEE 3.5. FASTENERS: TYPE S SELF TAPPING SCREWS IN SIZE AND SPACING AS REQUIRED FLOOR PLAN. FLOOR PLAN. BY FBC, OR UL RATED SYSTEM, NOTE: GWB TO STOP 4" ABOVE 4. INSTALLATION DROP CEILING U.N.O. 4.1. INSTALL METAL STUDS AND ACCESSORIES IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATION AND RECOMMENDED INDUSTRY PRACTICES. 4.2. ALIGN WALL ASSMEBLIES TO A TOLERANCE OF ONE IN 200 HORIONTALLY AND ONE IN 500 VERTICALLY. 4.3. PROVIDE THREES STUDS AT CORNERS, AND DOUBLE STUDS AT WALL OPENINGS. 4.4. COORDINATE WITH OTHER TRADES FOR PROPER LOCATIONS, SIZES, THICKNESS, AND ATTACHING REQUIREMENTS OF BACKING/BLOCKING. OPTIONAL BLANKET INSULATION OPTIONAL BLANKET INSULATION 4.5. COORDINATE WITH OTHER TRADES PIPES, DUCTS, CONDUITS WHICH ARE TO BE FOR SOUND PROOFING. SEE FOR SOUND PROOFING. SEE CONCEALED WITH WALL ASSEMBLIES. FLOOR PLAN. FLOOR PLAN. 4.6. EDGES OF DOOR IS LOCATED 4" OFF ADJACENT WALL EXCLUSIVE OF FAME. ALL OTHER DOOR OPENINGS ARE LOCATED TO ONE SIDE OF ROUGH OPENING, FRAME EXCLUSIVE. 4.7. GENERAL PLAN DIMENSIONS ARE FROM FINISH WALL SURFACE TO FINISH WALL SURFACE. AT CORRIDORS AND CRITICAL CLEAR DIMENSIONS WHERE 3 %" 20 GA. STEEL STUDS AT 16'' 3 A' 20 GA. STEEL STUDS AT 16" DIMENSIONS IS FROM FACE TO FINISHED GYPSUM BOARD ON SIDE WHERE O.C. (U.N.O.) O.C. (U.N.0.) CLEAR DIMENSION MUST BE HELD. 20 GA. GALV . STEEL CHANNEL 20 GA. GALV . STEEL CHANNEL FASTEN TO SLAB AT 24" O.C. FASTEN TO SLAB AT 24" O.C. EX. FLOOR SLAB CONCRETE FLOOR ENGINEERING & CONSTRUCTION AUSTIN CONSTRUCTION GROUP 2706 STALLONE DRIVE TAMPA, FLORIDA 33605 (813) 293-8883 FLORIDA PE 48917 192169 - CGC1521407 - CUC1224196 - CFC1430334 - FPC15-4000052 PROJECT INFORMATION: CLIENT: R►CHARD KAZBOUR PROJECT NAME: HUNGRY HOWIES RESTAURANT ADDITION PROJECT LOCATION: 5440 GALL BLVD ZEPHYRHILLS, FL 33542 SEAL: GOATS i .....E ��'•. ��i �o-- ,r_ � O ... FL COA NO. 30178 ENGINEER OF RECORD FL LICENSE NO. TO THE BEST OF THE ENGINEER'S KNOWLEDGE, THE PLANS AND SPECIFICATIONS COMPLY WITH THE APPLICABLE MINIMUM BUILDING CODES REVISIONS: NO. DATE COMMENTS SHEET TITLE: DOOR, WINDOW, AND WALL DETAILS SHEET INFORMATION: DRAWN: A.C. SHEET NO. DATE: 7/22/2024 CHECKED: K.C. DATE: 7/22/2024 A201 PROJECT NUMBER: SCALE: INDEX: AS SHOWN 0 w V) Q m c� z I I PLUMBING GENERAL NOTES 1 2 1 PLUMBING GENERAL NOTES 1 6 1 PLUMBING SCHEDULE I 1. ALL WORK UNDER THIS DIVISION WITH THE CODES AND STANDARDS AS LISTED ON THE PROJECT DRAWINGS AND TO OTHER PERTINENT CODES MADE A PART OF SUCH CODE BY REFERENCE. 2. TO THE BEST OF THE ENGINEERS KNOWLEDGE, THE PLANS COMPLY WITH THE APPLICABLE MINIMUM BUILDING CODES AND THE APPLICABLE FIRE -SAFETY STANDARDS AS DETERMINED BY THE LOCAL AUTHORITY IN ACCORDANCE WITH SECTION 110.8.4.4 OF THE FLORIDA BUILDING CODE AND 633 FLORIDA STATUES. 3. PLANS INDICATE THE SCHEMATIC LAYOUT AND LOCATION OF THE PLUMBING SYSTEM COMPONENTS. UNLESS SPECIFIC DIMENSIONS ARE NOTED, THE ACTUAL LOCATION OF THESE COMPONENTS SHALL BE DETERMINED IN THE FIELD IN COORDINATION WITH THE WORK OF OTHER TRADES, THE USE OF MANUFACTURER'S SHOP DRAWINGS AND SIMILAR CERTIFIED DATA. PLANS SHALL NOT BE SCALED. 4. NOTIFY THE ENGINEER OR HIS AUTHORIZED REPRESENTATIVE OF ANY DAMAGE TO THE EXISTING INSTALLATION BEFORE PROCEEDING WITH WORK. 24. ALL SANITARY, VENT AND WATER PIPING SHALL BE TESTED BEFORE CONCEALED IN ANY WAY. ALL JOINTS SHALL BE MADE DRIP TIGHT BEFORE BEING CONCEALED. DOMESTIC WATER PIPING SHALL BE TESTED AT 1-1 /2 TIMES OPERATING PRESSURE OR 100 PSI, WHICH EVER IS GREATER. 25. DISINFECT POTABLE WATER SYSTEM PER THE FBC. PROVIDE DOCUMENTATION IN THE CLOSE OUT DOCUMENTS. 26. PIPING TO THE INLET OF A WATER HEATER AND PIPING CONVEYING WATER HEATED BY A WATER HEATER SHALL BE INSULATED IN ACCORDANCE WITH SECTION C404.4 OF THE FLORIDA BUILDING CODE, ENERGY CONSERVATION. 1 3 1 CODE CRITERIA 5. WHERE THE CEILING SPACE IS USED AS A RETURN AIR PLENUM, ALL PLUMBING WORK IN THAT SPACE SHALL COMPLY WITH THE REQUIREMENTS OF NFPA-70 (NED) AS IT NOTE: RELATES TO THAT APPLICATION. THE USE OF PVC WITHIN THE PLENUM IS STRICTLY ALL CODES SHALL COMPLY WITH THE FLORIDA STATUES 69A-3.012 AND THE STATE FIRE PROHIBITED. COORDINATE WITH OTHER INSTALLERS TO PREVENT THE INSTALLATION MARSHALL'S RULE. THIS LIST IS NOT INCLUSIVE OF ALL CODES AND STANDARDS THAT OF PROHIBITED MATERIALS. MAY OR MAY NOT APPLY TO THIS PROJECT. 6. SUBMIT SHOP DRAWINGS OF ALL FIXTURES AND MATERIALS FOR REVIEW BY OWNER. INSTALL AND TEST ALL REQUIREMENT AND MATERIALS IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS AND RECOMMENDATIONS. SUBMIT DRAWINGS AND CUT SHEETS FOR ALL PRODUCTS ALL AT ONE TIME. INDEX ALL ITEMS TO THE PROJECT MANUAL OR DRAWINGS AS APPLICABLE. SHOP DRAWINGS THAT DEVIATE FROM THE REQUIREMENTS OF THE CONTRACT DOCUMENTS SHALL LIST ALL DIFFERENCES IN A COVER LETTER ATTACHED TO TOP OF T5HE SUBMITTAL. 7. PIPING AND OTHER ITEMS OF THE PLUMBING SYSTEM SHALL BE SUPPORTED DIRECTLY FROM THE BUILDING STRUCTURE AND NOT FROM THE CEILING, CEILING SUSPENSION SYSTEM, DUCTWORK, PIPING, OR ELECTRICAL SYSTEMS. 8. HANGERS, ANCHORS AND SUPPORTS SHALL SUPPORT THE PIPING AND CONTENTS OF THE PIPING HANGERS AND STRAFING MATERIALS SHALL BE OF APPROVED MATERIALS THAT WILL NOT PROMOTE GALVANIC ACTIONS. PROVIDE PIPE SADDLES BELOW INSULATED PIPES. 9. HANGERS AND ANCHORS SHALL BE ATTACHED TO THE BUILDING CONSTRUCTION IN AN APPROVED MANNER. 10. PROVIDE ALL OFFSETS AND FITTINGS REQUIRED FOR A FULLY FUNCTIONAL SYSTEM. MAKE CONNECTION TO SITE UTILITIES. COORDINATE WITH SITE UTILITY CONTRACTOR AS REQUIRED. 11. CONCEAL PIPING ABOVE CEILING, WITHIN WALL OR CHASES OR AS SPECIFICALLY NOTED. 12. ALL EXPOSED PIPE AND FITTINGS IN FINISHED AREAS SHALL BE CHROME PLATED. IF PIPING IS NOT AVAILABLE CHROME PLATED, PIPING SHALL BE PAINTED WITH CHROME COLORED PAINT. 13. COORDINATE PIPING WITH ALL ELECTRICAL EQUIPMENT (PANELS, TRANSFORMERS, ECT.) PRIOR TO ANY INSTALLATION. DO NOT ROUTE ANY PIPING OVER ANY ELECTRICAL DEVICES. 14. ALL WALL MOUNTED LAVATORIES SHALL BE ATTACHED TO FLOOR MOUNTED CARRIERS. 15. PRIOR TO ANY EXCAVATION OR DEMOLITION, THE CONTRACTOR SHALL COORDINATE HIS WORK WITH OTHER TRADES. 16. THE LOCATIONS OF ALL CLEANOUTS, VALVES, GAUGES, ECT. SHALL BE LOCATED FOR ACCESS AND/OR SERVICE IN REFERENCE TO THE FINISHED BUILDING. REFER TO THE DRAWINGS FOR APPLICABLE DETAILS. WALL CLEANOUT SHALL BE 18" A.F.F. 17. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LOCATION AND ROUGHING DIMENSIONS OF ALL PLUMBING FIXTURES, DRAINS, ECT. 18. DIELECTRIC UNIONS SHALL BE INSTALLED AT ALL CONNECTIONS OR DISSIMILAR METALS (SUCH AS COPPER TO GALVANIZED STEEL,) 19. WASTE AND SOIL PIPING SHALL BE PVC TYPE DWV AND SHALL CONFORM TO ONE OF THE FOLLOWING STANDARDS: ASTM D 2665, ASTM D 2949 OR CSA B181.2. FITING SHALL BE PVC AND SHALL CONFORM TO ONE OF THE FOLLOWING STANDARDS: ASTM D 2665, ASTM D 3311 OR ASTM F 1866. JOINTS SHALL BE SOLVENT CEMENTING. A PURPLE PRIMER THAT CONFORMS TO ASTM F 656 SHALL BE APPLIED TO JOINT SURFACES (CLEAN AND FREE FROM MOISTURE). SOLVENT CEMENT NOT PURPLE IN COLOR AND COFMING TO ASTM D 2564 OR CSA B137.3 SHALL BE APPLIED TO ALL JOINT SURFACES. JOINTS SHALL BE IN ACCORDANCE WITH ASTM D 2855. SLOPE ALL SANITARY PIPING 3" TO 6" AT A MINIMUM SLOPE OF g' PER FOOT 20. HOT AND COLD WATER PIPING SHALL BE CPVC AND SHALL CONFORM TO NSF 61 AND ONE OF THE FOLLOWING STANDARDS, ASTM B 75, ASTM B 88, ASTM B 251, OR ASTM B 447. FITTINGS SHALL BE COPPER OR COPPER ALLOY AND SHALL CONFORM TO NSF 61 AND ONE OF THE FOLLOWING STANDARDS ASME B16.15, ASME B16.18, ASME B16.23, ASME B16.23, ASME B16.26 OR ASME B16.29. SOLDERED JOINTS SHALL BE MADE IN ACCORDANCE WITH THE METHODS OF ASTM B828. THE JOINING OF WATER SUPPLY SHALL BE 95 LEAD FREE SOLDER AND THE SOLDER SHALL CONFORM TO ASTM B 32. 21. PROVIDE VALVES WHERE INDICATED ON PLAN AND NECESSARY FOR PROPER SYSTEM OPERATION AND COMPONENT ISOLATION. PROVIDE VALVES RATED FOR 125 PSI OR GREATER WORKING PRESSURE IN WATER PIPING. PROVIDE LEAD FREE BRONZE VALVES. BALL VALVES SHALL BE TWO-PIECE BODY, FULL PORT, WITH STAINLESS STEEL BALL. 22. SLOPE ALL SANITARY PIPING 3" TO 6" AT A MIN. SLOPE OF 1 /8" PER FOOT. ALL SANITARY PIPING 2-1/2" AND SMALLER SHALL BE SLOPED AT A MIN. OF 1 /4" PER FOOT. 23. ALL EXPOSED PIPING UNDER ACCESSIBLE LAVATORIES SHALL BE INSULATED WITH PROTECTIVE UNDER -SINK PIPE COVER AND PLUMBING ENCLOSURES AS MANUFACTURE SPECIFICATIONS. - FLORIDA BUILDING CODE (FBC), EIGHTH EDITION (2023) - ALL SECTIONS - FLORIDA BUILDING CODE (FBC), EIGHTH EDITION (2023) - PLUMBING - FLORIDA FIRE PREVENTION CODE 2023 NATIONAL FIRE PROTECTION ASSOCIATION (NFPA): - NFPA-70 (2020) NATIONAL ELECTRICAL CODE NFPA-72 (2019) NATIONAL FIRE ALARM CODE - NFPA-90A (2021) STANDARD FOR THE INSTALLATION OF AIR-CONDITIONING AND VENTILATING SYSTEMS NFPA-90B (2021) STANDARD FOR THE INSTALLATION OF WARM AIR HEATING AND AIR CONDITION SYSTEMS AMERICAN SOCIETY OF HEATING, REFRIGERATION AND AIR CONDITIONING ENGINEERS, INC (ASHRAE): - ASHRAE GUIDELINES 4-2019 - PREPARATION OF OPERATING AND MAINTENANCE DOCUMENTATION FOR BUILDING SYSTEMS - ASHRAE STANDARD 62.1-2019 AND APPROVED ADDENDA - VENTILATION FOR ACCEPTABLE INDOOR AIR QUALITY - ASHRAE STANDARD 126-2020 - METHOD OF TESTING HVAC AIR DUCTS - ASHRAE STANDARD 180-2018 -STANDARD PRACTICE FOR INSPECTION AND MAINTENANCE OF COMMERCIAL BUILDING HVAC SYSTEMS 4 1 ABBREVIATIONS SYMBOL DESCRIPTION AFF ABOVE FINISHED FLOOR CFM CUBIC FEET PER MINUTE CO CLEAN OUT BLDG BUILDING DIA DIAMETER ELEV ELEVATION EQUIP EQUIPMENT GPM GALLON PER MINUTE PVC POLYVINYL CHLORIDE PIPE FLEX FLEXIBLE GALV GALVANIZED VTR VENT THRU ROOF 5 1 PLUMBING LEGEND & SYMBOLS H W H W H W H W n COLD WATER (CPVC) HOT WATER (CPVC) SANITARY SOIL & WASTE (PVC) SANITARY SOIL & VENT (PVC) GAS LINE (BLACK IRON) PIPE DROP PIPE RISE HANGER SPACING MAXIMUM HORIZONTAL MAXIMUM HORIZONTAL PIPING MATERIAL SPACING (FEET) SPACING (FEET) COPPER OR COPPER -ALLOY TUBING 1-1/4" DIAMETER 6 10 AND SMALLER COPPER OR COPPER -ALLOY TUBING 1-1/2" DIAMETER 10 10 AND LARGER PVC PIPE 4 10 PLUMBING SCHEDULE MARK QTY ORDER BY SUPPLIED BY INSTALL BY DESCRIPTION MANUFACTURER MODEL # FAUCET WATER SUPPLY DRAIN COMMENTS P1 2 OWNER OWNER G.C. HAND SINK ATOSA USA, INC. MRS-HS-18(W) (OR EQUAL) INCLUDED 2' HOT AND COLD 2" INSTALL PER MANUFACTURER P2 1 OWNER OWNER G.C. THREE (3) COMPARTMENT SINK ATOSA USA, INC. MRSB-3-D (OR EQUAL) T&S 5PR-8W 12 2' HOT AND COLD 2" INSTALL PER MANUFACTURER P3 1 OWNER OWNER G.C. COMPARTMENT (1) SINK ATOSA USA, INC. MRSA-11 (OR EQUAL) T&S 5PR-8W12 2' HOT AND COLD 2" INSTALL PER MANUFACTURER P4 1 EX. EX. EX. GREASE TRAP EXISTING EXISTING - - - EXISTING +/- 1,000 GALLON CONCRETE TANK OUTSIDE OF BLDG. P5 1 EX. EX. EX. WATER HEATER EXISTING EXISTING - EXISTING - EXISTING GAS WATER HEATER OUTSIDE OF BLDG. P6 1 EX. EX. EX. MOP SINK EXISTING EXISTING - EXISTING EX. EXISTING MOP SINK TO BE UTILIZED P7 1 G.C. G.C. G.C. MOP SINK PROFLO PFMB2424 (OR EQUAL) PF1 119 HOT AND COLD 3" INSTALL PER MANUFACTURER F.S. 2 G.C. G.C. G.C. FLOOR SINK ZURN FD2376-NH3-H (OR EQUAL) - - 3" 12"X12" FLOOR SINK FOR 3 COMPARTMENT SINK F.D. 2 G.C. G.C. G.C. FLOOR DRAIN ZURN ZN415-2NL-5B-P (OR EQUAL) - - 3" 3" PUSH ON FLOOR DRAIN AM �® fiff AV ENGINEERING & CONSTRUCTION AUSTIN CONSTRUCTION GROUP 2706 STALLONE DRIVE TAMPA, FLORIDA 33605 (813) 293-8883 FLORIDA PE 48917 192169 - CGC1521407 - CUC1224196 - C F C 1430334 - F P C 15-4000052 PROJECT INFORMATION: CLIENT: RICHARD KAZBOUR PROJECT NAME: HUNGRY HOWIES RESTAURANT ADDITION PROJECT LOCATION: 5440 GALL BLVD ZEPHYRHILLS, FL 33542 SEAL: ```�1� i 1l I I I►I //4 Go ATS �� E ••.. �� .` •.• NS .�co.• •. �� :. • -- FL COA NO. 30178 ENGINEER OF RECORD FL LICENSE NO. TO THE BEST OF THE ENGINEER'S KNOWLEDGE, THE PLANS AND SPECIFICATIONS COMPLY WITH THE APPLICABLE MINIMUM BUILDING CODES REVISIONS: NO. DATE COMMENTS SHEET TITLE: PLUMBING NOTES & SCHEDULE SHEET INFORMATION: DRAWN: A.C. SHEET NO. DATE: 7/22/2024 CHECKED: K.C. DATE: 7/22/2024 Po . 1 PROJECT NUMBER: SCALE: INDEX: AS SHOWN 1 1 PLUMBING WATER PLAN SCALE: 1 /4" = l'-0" 2 PAGE KEY NOTES ❑# MARK NOTES 1 SHADED AREA IS OUT OF SCOPE OF WORK. NEW WATER LINE CONNECT TO EXISTING WATER LINE ABOVE CEILING. FIELD 2 VERIFY EXACT LOCATION IN FIELD. NEW HOT WATER LINE CONNECT TO EXISTING HOT WATER LINE ABOVE 3 CEILING. FIELD VERIFY EXACT LOCATION IN FIELD. EXISTING GAS WATER HEATER. CONTRACTOR TO INSTALL PROTECTIVE ANTI -THEFT CAGE AROUND HEATER. CONTRACTOR TO COORDINATE WITH 4 OWNER PRIOR TO ORDERING AND INSTALLING CAGE FOR CORRECT SIZE AND LOCATION. 5 - 6 - 7 8 - 9 - 1 3 1 PLUMBING WATER ISOMETRICS SCALE: N.T.S. 3/4" 3/4" / I 3 3/4'' / / 3/4" 1/2°1 I }, 1/2" 2 II I� i Pl 3/4" I i 3/4' j 3/4" 3/4" / I 1/2" 1/2" / 3/4" / I 1/2" 3/4'' 1/2" 3/4" 1 /2" P7 1/2"I 1/2" i 1/2" I P3 1 \ ENGINEERING & CONSTRUCTION AUSTIN CONSTRUCTION GROUP 2706 STALLONE DRIVE TAMPA, FLORIDA 33605 (813) 293-8883 FLORIDA PE 48917 192169 - CGC 1521407 - CUC 1224196 - CFC1430334 - FPC15-4000052 PROJECT INFORMATION: CLIENT: RICHARD KAZBOUR PROJECT NAME: HUNGRY HOWIES RESTAURANT ADDITION PROJECT LOCATION: 5440 GALL BLVD ZEPHYRHILLS, FL 33542 SEAL: t%%J11111111/1��` G®ATS ••NSE '•. �� •. �. J — - UJ cfr •�'• i F LO FL COA NO. 30178 ENGINEER OF RECORD FL LICENSE NO. TO THE BEST OF THE ENGINEER'S KNOWLEDGE, THE PLANS AND SPECIFICATIONS COMPLY WITH THE APPLICABLE MINIMUM BUILDING CODES REVISIONS: NO. DATE COMMENTS SHEET TITLE: PLUMBING WATER PLAN SHEET INFORMATION: DRAWN: A.C. SHEET NO. DATE: 7/22/2024 CHECKED: K.C. DATE: 7/22/2024 pI • PROJECT NUMBER: SCALE: INDEX: AS SHOWN 1 PLUMBING WATER PLAN SCALE: 1/4" 1'-0" 2 PAGE KEY NOTES = 6a p sQ a ag' ®a a� a .a as a ®a P6 s® e a A as P4 °� a a. �p p as as a ao a a a �p I I 1/7 AREA NOT IN PROJECT SCOPE 2 P7 F.S. F.S. O O O O a Pl F.D. F.D. 2' 2' V.T.R. 3 PLUMBING SANITARY ISOMETRICS SCALE: N.T.S. O 0 0 o P7 0 l / / 2" e 4„ P 1 4" ❑ ❑ - r I P3 F.D. 2' o � ` 2"i 4' ml I Pl 4" 2 4" F.D. MARK NOTES 1 SHADED AREA IS OUT OF SCOPE OF WORK. 2 CONNECT TO EXISTING 4" GREASE STUB -UP PER AS -BUILT PLANS. 4" SANITARY PIPING CONNECTED TO EXISTING CONCRETE GREASE TRAP. 3 - 4 - 5 - 6 - 7 - 8 - 9 -ojilillfilill ENGINEERING &CONSTRUCTION AUSTIN CONSTRUCTION GROUP 2706 STALLONE DRIVE TAMPA, FLORIDA 33605 (813) 293-8883 FLORIDA PE 48917 192169 - CGC1521407 - CUC1224196 - CFC 1430334 - FPC] 5-4000052 PROJECT INFORMATION: CLIENT: RICHARD KAZBOUR PROJECT NAME: HUNGRY HOWIES RESTAURANT ADDITION PROJECT LOCATION: 5440 GALL BLVD ZEPHYRHILLS, FL 33542 SEAL: 9a s r F~� S E � • 4L ram' � Oj % s •A�� P 1 1 PLUMBING GAS PLAN SCALE : N.T.S. PAGE KEY NOTES MARK NOTES 1 SHADED AREA IS OUT OF SCOPE OF WORK. 2 EXISTING GAS CONNECTION TO UNIT. FIELD VERIFY EXACT CONNECTION AND SIZE IN FIELD. FIELD VERIFY EXISTING METER AND REGULAR IN FIELD AND CONTACT GAS SUPPLIER AS NECESSARY. 3 CONNECT TO EXISTING GAS LINE WITH NEW 2" SCH40 BLACK IRON GAS PIPE. SUPPORT FROM CEILING 6' ON CENTER, MAXIMUM SPACING. TOTAL APPROXIMATE LENGTH = 75-0", 900,000 BTUH 4 CONNECT TO EQUIPMENT WITH FLEXIBLE HOSE CONNECTIONS PER DETAIL. COORDINATE WITH EQUIPMENT MANUFACTURER SPECIFICATIONS AND LOCATIONS. (TYP.) 5 - 6 - 7 - 8 - 9 - 3 FLEXIBLE GAS CONNECTION SCHEMATIC MECHANICAL VALVE NOTE: FURN. BY COOKING UTILIZE DORMONT CONNECTION EQUIPMENT F.P. CONTR. EQUIPMENT OR APPROVED EQUAL INSTALLED BY PLBG. CONTR. 1'-0" ABOVE CEILING RELEASE & CABLE BY COOKING EQUIPMENT FIRE PROTECTION CONTR. MOUNT ALONG WALL OR rA AT COLUMN GAS COCK DORMONT SSG-1675-BPQ- 3/4'' STAINLESS STEEL FLEXIBLE CONNECTOR 5-0" LONG (SEE SPEC.) DORMONT MODEL RDC-60 48'' LONG RESTRAINING DEVICE WOOD BLOCKING FOR DRY WALL ONLY 1 4 1 PLUMBING GAS ISOMETRICS SCALE: N.T.S. 2" G 3 2'' SHUT OFF VALVE 2" G ,,J ENGINEERING & CONSTRUCTION AUSTIN CONSTRUCTION GROUP 2706 STALLONE DRIVE TAMPA, FLORIDA 33605 (813) 293-8883 FLORIDA PE 48917 192169 - CGC 1521407 - CUC 1224196 - CFC 1430334 - FPC 15-4000052 PROJECT INFORMATION: CLIENT: RICHARD KAZBOUR PROJECT NAME: HUNGRY HOWIES RESTAURANT ADDITION PROJECT LOCATION: 5440 GALL BLVD ZEPHYRHILLS, FL 33542 SEAL: co ATS ..... d S E •••N 4009 add �� •Osa.aaaaa°a �/ �� FL COA NO. 30178 ENGINEER OF RECORD FL LICENSE NO. TO THE BEST OF THE ENGINEER'S KNOWLEDGE, THE PLANS AND SPECIFICATIONS COMPLY WITH THE APPLICABLE MINIMUM BUILDING CODES REVISIONS: NO. DATE COMMENTS SHEET TITLE: PLUMBING GAS PLAN SHEET INFORMATION: DRAWN: A.C. SHEET NO. DATE: 7/22/2024 CHECKED: K.C. DATE: 7/22/2024 PI • 3 PROJECT NUMBER: SCALE: INDEX: AS SHOWN 1 1 MECHANICAL GENERAL NOTES 3 1 CODE CRITERIA 0 MECHANICAL SCHEDULE 1. PLANS INDICATE THE SCHEMATIC LAYOUT AND LOCATION OF THE MECHANICAL NOTE: SYSTEM COMPONENTS. UNLESS SPECIFIC DIMENSIONS ARE NOTED, THE ACTUAL ALL CODES SHALL COMPLY WITH THE FLORIDA STATUES 69A-3.012 AND THE STATE FIRE MARSHALL'S RULE. THIS LIST IS NOT INCLUSIVE OF ALL CODES AND ROOFTOP UNIT SCHEDULE LOCATION OF THESE COMPONENTS SHALL BE DETERMINED IN THE FIELD IN STANDARDS THAT MAY OR MAY NOT APPLY TO THIS PROJECT. COORDINATION WITH THE WORK OF OTHER TRADES. THE USE OF MANUFACTURER'S EVAPORATOR SECTION HEATER ELECTRIC UNIT UNIT SHOP DRAWINGS AND SIMILAR CERTIFIED DATA. PLANS SHALL NOT BE SCALED. - FLORIDA BUILDING CODE (FBC), EIGHTH EDITION (2023) - ALL SECTIONS PLAN MANUF. MODEL # TOTAL SENS. WEIGHT EFF. NOTES - FLORIDA BUILDING CODE (FBC), EIGHTH EDITION (2023) ENERGY MARK SUPPLY OSA CFM E.A.T L.A.T COOLING COOLING HEATER ELECTRIC (LBS.) (IEER) 2. WHERE THE CEILING SPACE IS USED AS A RETURN AIR PLENUM, ALL ELECTRICAL CONSERVATION SOFTWARE: ENERGY GAUGE SUMMIT VERSION 8.00 CFM (DB/WB) (DB/WB) (BTUH) (BTUH) (KW) V/• WORK IN THAT SPACE SHALL COMPLY WITH THE REQUIREMENTS OF NFPA-70 (NEC) FLORIDA FIRE PREVENTION CODE 2023 RTU-1 EXISTING EXISTING +/- 10,000 800 EXISTING EXISTING EXISTING EXISTING EXISTING 208/3 EXISTING EXISTING 1 AS IT RELATES TO THAT APPLICATION. EXPOSED WIRE SHALL BE PLENUM RATED. THE NATIONAL FIRE PROTECTION ASSOCIATION (NFPA): MUA-2 CAPTIVEAIRE Al-15D-MPU 1,980 - 91/77 75/69.1 60,000 33,500 - - 1088 - 2 USE OF PVC WITHIN THE PLENUM IS STRICTLY PROHIBITED. COORDINATE WITH OTHER - NFPA-70 (2020) NATIONAL ELECTRICAL CODE - - - - - - - - - - - - - - INSTALLERS TO PREVENT THE INSTALLATION OF PROHIBITED MATERIALS. - NFPA-72 (2019) NATIONAL FIRE ALARM CODE NOTES: - NFPA-90A (2021) STANDARD FOR THE INSTALLATION OF 1. EXISTING ROOFTOP UNIT TO REMAIN, FIELD VERIFY EXISTING CONDITIONS AIR-CONDITIONING AND VENTILATING SYSTEMS 2. COORDINATE WITH CAPTIVEAIRE SHOP DRAWINGS FOR INSTALLATION INFORMATION AND DETAILS 3. DUCTWORK, AIR DEVICES AND OTHER ITEMS OF THE AIR DISTRIBUTION SYSTEM SHALL _ NFPA-90B (2021) STANDARD FOR THE INSTALLATION OF WARM AIR BE SUPPORTED DIRECTLY FROM THE BUILDING STRUCTURE AND NOT FROM THE HEATING AND AIR CONDITION SYSTEMS CEILING OR CEILING SUSPENSION SYSTEM. COORDINATE LOCATION OF AIR DEVICES WITH ELECTRICAL, ENGINEER, FIRE PROTECTION AND PLUMBING WORK. AIR DEVICES AMERICAN SOCIETY OF HEATING, REFRIGERATION AND AIR CONDITIONING FAN SCHEDULE ENGINEERS, INC (ASHRAE): SHALL BE SUPPORTED FROM THE BUILDING STRUCTURE FROM AT LEAST TWO POINTS. - ASHRAE GUIDELINES 4-2019 - PREPARATION OF OPERATING AND MARK AREA SERVED TYPE CFM HP FLA R.P.M. VOLTS/PH SONES MANUFACTURER & MODEL NO. NOTES MAINTENANCE DOCUMENTATION FOR BUILDING SYSTEMS KEF-2 KITCHEN ROOF TOP 2,200 2.0 8.3 1 151 208 / 3 13.7 CAPTIVEAIRE DU 180HFA 1 4. ALL DUCTWORK SHALL BE FABRICATED AND INSTALLED IN ACCORDANCE WITH THE - ASHRAE STANDARD 62.1-2019 AND APPROVED ADDENDA - VENTILATION - - - - - - - - - - LATEST EDITION OF "SMACNA" DUCT CONSTRUCTION STANDARDS AND COMPLY FOR ACCEPTABLE INDOOR AIR QUALITY WITH THE LATEST "NFPA" 90A REQUIREMENTS. ALL DUCTWORK SHALL BE LEAK TESTED - ASHRAE STANDARD 126-2020 - METHOD OF TESTING HVAC AIR DUCTS NOTES: IN ACCORDANCE WITH SMACNA AND ASHRAE STANDARDS, AND BE COMPLETED - ASHRAE STANDARD 180-2018 - STANDARD PRACTICE FOR INSPECTION 1. COORDINATE WITH CAPTIVEAIRE SHOP DRAWINGS FOR INSTALLATION INFORMATION AND DETAILS AND MAINTENANCE OF COMMERCIAL BUILDING HVAC SYSTEMS BY THE TEST AND BALANCE COMPANY, DUCTS WITH A LEAKAGE RATE MORE THAN 2% WILL BE REJECTED. AIR DEVICE SCHEDULE FABRICATED DUCTWORK TO THE FOLLOWING DUCT PRESSURE CLASS: MARK DESCRIPTION FACE SIZE NECK MATERIAL MANUFACTURER & MODEL NO. NOTES DUCT PRESSURE CLASS OPERATING PRESSURE 4 ABBREVIATIONS A LOUVERED FACE RETURN GRILLE 24"x24" SEE PLAN ALUMINUM VENT -AIR FILTER GRILLE 1,2 2" W.G. UP TO 2" W.G. B LOUVERED FACE SUPPLY DIFFUSER 24' x 24" SEE PLAN ALUMINUM VENT 1-AIR-HT3D081 1,2 1" W.G. OVER z" UP TO 1" W.G. _ - - - - - SYMBOL DESCRIPTION NOTES: DUCTWORK SHALL BE SEALED TO: AFF ABOVE FINISHED FLOOR 1. COORDINATE SURFACE FINISHES WITH OWNER. AHU AIR HANDLING UNIT 2. SUPPLY COMPLETE FACTORY INSTALLED 1 /2" THICK FOIL BACKED INSULATION. APPLICABLE DUCT PRESSURE CLASS SEAL CLASS 2" W.G. AND BELOW A BTU BRITISH THERMAL UNIT BLDG BUILDING 5. ALL DUCT DIMENSIONS SHOWN ON DRAWINGS ARE CLEAR INSIDE DIMENSIONS. CFM CUBIC FEET PER MINUTE FLEX DUCT OUTSIDE AIR CALCULATIONS DIA DIAMETER 6. SUPPLY AND EXHAUST AIR DUCTWORK SHALL BE DUCT BOARD (MINIMUM INSTALLED ELEV ELEVATION OCC. FACTOR AHRAE 62 VALUES PER SPACE SPACE SCHEDULE R = 6.0). SEAL ALL DUCT JOINTS WITH HARDCASE. DUCT INSULATION SHALL BE ) EQUIP EQUIPMENT CLASSIFICATION OCCUPANCY/ 1000 TABLE 6-1 AREA (SQFT) LOAD (PERSONS) OUTDOOR AIR REQUIRED (CFM) OUTDOOR AIR SUPPLIED(CFM) CFM FLEX SIZE LABELED AND MARKED AT REQUIRED INTERVALS PER THE FLORIDA BUILDING CODE. EA EXHAUST AIR SQFT. (PERSONS) Rp Ra Az Pz 0 - 50 • ••• EF EXHAUST FAN 51 - 100 • ••• KITCHEN 20 7.5 0.12 2800 56 756 800 7. ALL VOLUME DAMPERS SHALL BE OPPOSED BLADE TYPE. PROVIDE A ONE FOOT FLEX FLEXIBLE 101 - 200 • ••• LONG PLASTIC STRIP OF MATERIAL FROM ALL DAMPER HANDLES TO ASSIST TEST AND GALV GALVANIZED 201 - 400 • • •» BALANCE AGENCY IN THE IDENTIFYING ALL DAMPERS. IN AREAS WHERE THE FINAL RA RETURN AIR - 600 • • ••• TOTAL 2800 56 756 800 DAMPER INSTALLATION PROHIBITS ACCESS FOR TEST AND BALANCE, PROVIDE SA SUPPLY AIR NOTE: 601 01 - 900 • • ••• POWER BALANCING DAMPERS AS MANUFACTURED REQUIRED FOR A COMPLETE T THERMOSTAT REQUIRED OUTDOOR VENTILATION AIR VALUES TAKEN FORM ASHRAE 62, TABLE 6-1. 901 - 1,300 • • •» TYP TYPICAL VENTILATION BREATHING ZONE FORMULA: Vbz = Rp * Pz + Ra * Az AND OPERATIONAL SYSTEM. (PROVIDE MANUAL REMOTE CABLE CONTROLS EQUAL VD VOLUME DAMPER Pz = OCCUPANCY FACTOR * SPACE AREA TO YOUNG REGULATOR MODEL 830ACC/270-896. ACCESS TO END OF CABLE TO BE FLUSH IN CEILING NEATLY CONCEALED WITH THREADED CAP. PAINT CAP TO MATCH NOTE: AREA DOES NOT INCLUDE RESTROOMS AND SHOWER ROOMS. SHOP AREA NOTE: SHOP AREA WILL BE CEILING COLOR. REMOVE MATERIAL FROM EXPOSED DUCT DAMPERS AFTER NATURALLY VENTILATED DURING WORK HOURS. SEE SHEET M1.0 FOR CALCULATION & NOTES. SUBSTANTIAL COMPLETION). 8. PROVIDE CONICAL SPIN -IN FITTINGS AT ALL CONNECTIONS OF ROUND SHEET METAL OR FLEXIBLE SUPPLY AIR DUCTS TO RIGID RECTANGULAR DUCT. 5 PLUMBING LEGEND & SYMBOLS 9. ALL PIPING AND /OR DUCTWORK MUST BE INSTALLED b" AWAY FROM ANY FIRE RATED WALL. 10. FLEXIBLE DUCTS SHALL BE FACTORY INSULATED WITH 3/4" THICK GLASS FIBER AND "THERMAFLEX" SUPPLY DIFFUSER. (4-WAY) INCLUDE A VINYL VAPOR JACKET AND HELIX STEEL WIRE. TYPE M-KE OR APPROVED EQUAL. FLEXIBLE DUCT SHALL BE ATTACHED WITH "THERMAFLEX" RETURN OR OUTDOOR AIR GRILLE WRAP LOCK SERIES 0902 CLAMPS. MAXIMUM LENGTH OF FLEXIBLE DUCT SHALL BE 6-0". EXHAUST GRILLE 11. ALL WALL MOUNTED TEMPERATURE AND HUMIDITY SENSORS SHALL BE INSTALLED AT RECTANGULAR DUCTWORK WITH TAKE -OFF, A CENTER LINE ELEVATION OF 4'-0" ABOVE FINISHED FLOOR UNLESS OTHERWISE BALANCING DAMPER AND INSULATED FLEXIBLE NOTED ON DRAWINGS. LOCATION OF THE WALL MOUNTED THERMOSTAT SHALL BE A B ROUND DUCT. SAME SIZE AS DIFFUSER INLET UNLESS NOTED OTHERWISE. FIRST DIMENSION IS THAT OF SIDE COORDINATED WITH THE OTHER TRADES FOR A NEAT APPEARANCE. FINAL SHOWN. LOCATION OF THERMOSTAT SHALL BE SUBJECT TO THE APPROVAL OF THE ENGINEER OR THE OWNER IN THE FIELD. WHEN INSTALLED ON EXTERIOR WALLS, PROVIDE AN A ROUND DUCTWORK. INSULATED SUB -BASE. MANUEL DAMPER 12. RETAIN THE SERVICES OF A NEBB AND/OR AABC CERTIFIED TEST AND BALANCE AGENCY TO PERFORM FINAL TESTING AND BALANCING OF ALL HVAC SYSTEMS. RECORD ALL DATA ON STANDARD "AABC" OR OTHER APPROVED FORMS, AND FIRE DAMPER WITH ACCESS PANEL, SUBMIT TO THE ENGINEER FOR REVIEW. 13. ALL NEW DUCTWORK SHALL BE STORED IN CLEAN AREAS. PROTECT ALL DUCTWORK EXISTING DUCTWORK TO BE REMOVED (DASHED LINETYPE) FROM DUST AND DEBRIS WHILE IT IS STORED ON SITE. WHILE UNDER CONSTRUCTION, ALL INSTALLED DUCTWORK SHALL BE TEMPORARILY SEALED WITH VISQUEEN PRIOR DUCT MOUNTED SMOKE DETECTOR PROVIDED AND WIRED BY ELECTRICAL CONTRACTOR AND INSTALLED IN DUCT BY TO TEST AND BALANCE IN ORDER TO LIMIT ACCUMULATION OF CONSTRUCTION MECHANICAL CONTRACTOR. REFER TO SPECIFICATIONS FOR DUST INSIDE DUCTWORK SYSTEM. IF EITHER OF THESE PROCEDURES IS NOT CONTROL REQUIREMENTS. CONDUCTED, THE ENTIRE ASSOCIATED DUCTWORK SYSTEM AND MECHANICAL AIR DEVICE TAG EQUIPMENT SHALL BE CLEANED TO THE OWNER'S SATISFACTION. A-100 MARK-CFM SIDEWALL TRANSFER GRILLE 2 NOTES: �j IXII SIDEWALL SUPPLY REGISTER 1. THE NOTES SHOWN ON THIS SHEET APPLY TO GENERAL CONDITIONS OF HEATING, �-�y VENTILATING AND AIR CONDITIONING WORK REQUIRED FOR THIS PROJECT. TS WALL MOUNTED DDC TEMPERATURE SENSOR MOUNT 5-0" ABOVE FINISHED FLOOR. 2. SPECIFICATIONS,PROJECT MANUALS AND DRAWINGS, REFER TO THIS SHEET FOR APPLICABLE REFERENCES. O WALL MOUNTED THERMOSTAT MOUNT 48" ABOVE FINISHED FLOOR. 3. THE DESIGN DRAWINGS OF ALL CATEGORIES AND TRADES (ARCHITECTURAL, STRUCTURAL, PLUMBING, MECHANICAL, HEATING, VENTILATING AND AIR CONDITIONING, AND ELECTRICAL) AND ALL SPECIFICATIONS AND SHOP DRAWINGS MUST BE COORDINATED AND VIEWED IN CONNECTION AND CONJUNCTION WITH EACH OTHER TO INSURE THE PROPER LOCATION OF ALL DEVICES AND EQUIPMENT. MAKE PARTICULAR NOTE OF LOCATIONS AND DIMENSIONS SHOWN ON THE FLOOR PLANS AND ELEVATIONS. 4. TO THE BEST OF THE ENGINEER'S KNOWLEDGE, THE PLANS AND SPECIFICATIONS COMPLY WITH THE APPLICABLE MINIMUM BUILDING CODES AND THE APPLICABLE FIRE -SAFETY STANDARDS AS DETERMINED BY THE LOCAL AUTHORITY IN ACCORDANCE WITH SECTION 110.8.4.4 OF THE BUILDING CODE AND 633 FLORIDA STATUTES. ^Gap ENGINEERING & CONSTRUCTION AUSTIN CONSTRUCTION GROUP 2706 STALLONE DRIVE TAMPA, FLORIDA 33605 (813) 293-8883 FLORIDA PE 48917 192169 - CGC1521407 - CUC1224196 - CFC 1430334 - FPC 15-4000052 PROJECT INFORMATION: CLIENT: RICHARD KAZBOUR PROJECT NAME: HUNGRY HOWIES RESTAURANT ADDITION PROJECT LOCATION: 5440 GALL BLVD ZEPHYRHILLS, FL 33542 SEAL: GOATS',I�����i.r s r • •sosr^ttRL `� ""flat 1 FL COA NO. 30178 ENGINEER OF RECORD FL LICENSE NO. TO THE BEST OF THE ENGINEER'S KNOWLEDGE, THE PLANS AND SPECIFICATIONS COMPLY WITH THE APPLICABLE MINIMUM BUILDING CODES REVISIONS: NO. DATE COMMENTS SHEET TITLE: MECHANICAL NOTES & SCHEDULE SHEET INFORMATION: DRAWN: A.C. SHEET NO. DATE: 7/22/2024 CHECKED: K.C. DATE: 7/22/2024 moo I PROJECT NUMBER: SCALE: INDEX: AS SHOWN 1 1 EXISTING MECHANICAL PLAN SCALE: 1/4"= 1'-0" 2 PAGE KEY NOTES MARK NOTES 1 SHADED AREA IS OUT OF SCOPE OF WORK. 2 EXISTING RETURN AIR BANK TO REMAIN. REPLACE GRILLS WITH NEW PER SCHEDULE (TYP.) 3 EXISTING 12'' X 12" SUPPLY GRILLS TO BE REPLACED WITH NEW 24" X 24"GRILLS AND FIT TO EXISTING CEILING GRID. SEE SCHEDULE (TYP.) 4 5 - 6 - 7 - 8 - 9 - ENGINEERING & CONSTRUCTION AUSTIN CONSTRUCTION GROUP 2706 STALLONE DRIVE TAMPA, FLORIDA 33605 (813) 293-8883 FLORIDA PE 48917 192169 - CGC1521407 - CUC1224196 - CFC 1430334 - FPC 15-4000052 PROJECT INFORMATION: CLIENT: RICHARD KAZBOUR PROJECT NAME: HUNGRY HOWIES RESTAURANT ADDITION PROJECT LOCATION: 5440 GALL BLVD ZEPHYRHILLS, FL 33542 SEAL: 10%%j III I f ill/i ♦♦ �� . �N SE .�• ,� 2,60 S: d �• �pg • U1 _ • • � L1J F 0 _ FL COA NO. 30178 ENGINEER OF RECORD FL LICENSE NO. TO THE BEST OF THE ENGINEER'S KNOWLEDGE, THE PLANS AND SPECIFICATIONS COMPLY WITH THE APPLICABLE MINIMUM BUILDING CODES REVISIONS: NO. DATE COMMENTS SHEET TITLE: EXISTING MECHANICAL PLAN SHEET INFORMATION: DRAWN: A.C. SHEET NO. DATE: 7/22/2024 CHECKED: K.C. DATE: 7/22/2024 mI • PROJECT NUMBER: SCALE: INDEX: AS SHOWN I I PROPOSED MECHANICAL PLAN SCALE: 1/4"= 1'-0" 2 1 PAGE KEY NOTES MARK NOTES 1 SHADED AREA IS OUT OF SCOPE OF WORK. EXISTING RETURN AIR BANK. CONTRACTOR TO COORDINATE WITH OWNER ON 2 NEW LOCATION AND REPLACE GRILLS WITH NEW PER SCHEDULE. (TYP.) NEW 24"X24" GRILLS TO FIT IN EXISTING CEILING GRID. UTILIZE EXISTING FLEX 3 DUCT AND MAKE NECESSARY REPAIRS TO DUCT AS NEEDED. SEE SCHEDULE (TYP.) COMMERCIAL TYPE 1 HOOD. SEE MANUFACTURER PLANS AND 4 SPECIFICATIONS FOR DETAILS. SEE MECHANICAL ROOF PLAN ON SHEET M1.3. EXISTING RESTROOM EXHAUST FANS TO BE TESTED TO VERIFY PROPERLY 5 WORKING ORDER. IF EXHAUST FANS ARE NOT WORKING, CONTRACTOR TO COORDINATE WITH OWNER ON COST TO REPLACE WITH IN -KIND REPLACEMENT 6 - 7 - 8 - 9 - AM - - ENGINEERING & CONSTRUCTION AUSTIN CONSTRUCTION GROUP 2706 STALLONE DRIVE TAMPA, FLORIDA 33605 (813) 293-8883 FLORIDA PE 48917 192169 - CGC1521407 - CUC1224196 - CFC 1430334 - FPC 15-4000052 PROJECT INFORMATION: CLIENT: RICHARD KAZBOUR PROJECT NAME: HUNGRY HOWIES RESTAURANT ADDITION PROJECT LOCATION: 5440 GALL BLVD ZEPHYRHILLS, FL 33542 SEAL: `,`��titttt t r►rr����f GOATS �iee �J • ♦.....♦ti ee 'cb ♦ G g ♦ s �'//i///I O�• ;ESS;ov rrt FL COA NO. 30178 ENGINEER OF RECORD FL LICENSE NO. TO THE BEST OF THE ENGINEER'S KNOWLEDGE, THE PLANS AND SPECIFICATIONS COMPLY WITH THE APPLICABLE MINIMUM BUILDING CODES REVISIONS: NO. DATE COMMENTS SHEET TITLE: PROPOSED MECHANICAL PLAN SHEET INFORMATION: DRAWN: A.C. SHEET NO. DATE: 7/22/2024 CHECKED: K.C. DATE: 7/22/2024 M1,2 PROJECT NUMBER: SCALE: INDEX: AS SHOWN 1 1 MECHANICAL ROOF PLAN SCALE: 1/4"=1'-0° 1 2 1 PAGE KEY NOTES [#] MARK NOTES EXISTING RTU TO REMAIN. SEE ROOF TOP UNIT SCHEDULE AND VERIFY EXACT 1 LOCATIONS IN FIELD. ROOF TOP EXHAUST AND SUPPLY FAN FROM KITCHEN HOOD. INSTALL 2 CURBING FOR EQUIPMENT PER MANUF. WALK-IN COOLER EXTERNAL CONDENSING UNIT. INSTALL CURBING AND 3 EQUIPMENT PER MANUF. 4 FOR MUA-1 ROOF TOP EQUIPMENT INSTALL STRUCTURAL BRACING AND COLUMN. SEE STRUCTURAL PLAN FOR DETAIL. 5 - 6 - 7 - 8 - 9 - -® ^Gw ENGINEERING & CONSTRUCTION AUSTIN CONSTRUCTION GROUP 2706 STALLONE DRIVE TAMPA, FLORIDA 33605 (813) 293-8883 FLORIDA PE 48917 192169 - CGC1521407 - CUC1224196 - CFC1430334 - FPC15-4000052 PROJECT INFORMATION: CLIENT: RICHARD KAZBOUR PROJECT NAME: HUNGRY HOWIES RESTAURANT ADDITION PROJECT LOCATION: 5440 GALL BLVD ZEPHYRHILLS, FL 33542 SEAL: GOATS A?• ;SE .� Jam. `G� ,�69 •S d .. • LJ =: OF Z _ � lEs s'1P FL COA NO. 30178 ENGINEER OF RECORD FL LICENSE NO. TO THE BEST OF THE ENGINEER'S KNOWLEDGE, THE PLANS AND SPECIFICATIONS COMPLY WITH THE APPLICABLE MINIMUM BUILDING CODES REVISIONS: NO. DATE COMMENTS SHEET TITLE: MECHANICAL ROOF PLAN SHEET INFORMATION: DRAWN: A.C. SHEET NO. DATE: 7/22/2024 CHECKED: K.C. DATE: 7/22/2024 M13 PROJECT NUMBER: SCALE: INDEX: AS SHOWN I I ELECTRICAL GENERAL NOTES GENERAL: l . PROVIDE SHALL MEAN FURNISH AND INSTALL. 2. THE COMPLETE ELECTRICAL SYSTEM SHALL BE PROVIDED BY THE CONTRACTOR SHALL INCLUDE ALL WORK, MATERIALS AND APPARATUSES SPECIFIED HEREINAFTER AND INDICATED ON THE DRAWINGS. ALL WORKMANSHOP SHALL BE OF THE HGIHEST QUALITY AND NO SUBSTANDARD WORK WILL BE ACCEPTED, 3. PROVIDE ALL WORK AND ELECTRICAL SYSTEMS COMPONENTS REQUIRED TO SERVE LOADS AS SPECIFIED HEREINAFTER AND INDICATED IN THE DRAWINGS. THE WORK SHALL INCLUDE COMPLETE TESTING OF ALL ELECTRICAL SYSTEMS AT THE COMPLETION OF THE WORK AND MAKE ANY CHANGES AND ADJUSTMENTS NECESSARY FOR THE PROPER FUNCTIONING OF THE SYSTEMS. 4. MAKE A THOROUGH EXAMINATION OF THE SITE AND THE CONTRACT DOCUMENTS PRIOR TO EXECUTING THE CONTRACT. NO CLAIM FOR ADDITIONAL COMPENSATION WILL BE RECOGNIZED FOR DIFFICULTIES ENCOUNTERED WHICH AN EXAMINATION OF SITE CONDITIONS AND CONTRACT DOCUMENTS WOULD HAVE REVEALED. 5. ALL ELECTRICAL EQUIPMENT SHALL BE INSTALLED ABOVE THE FLOODPLAIN ELEVATION. CONTRACTOR SHALL COORDINATE FLOODPLAIN ELEVATION AND EQUIPMENT REQUIREMENTS WITH OWNER PRIOR TO ROUGH -IN. 6. THE PLANS ARE GENERALLY DIAGRAMMATIC. COORDINATE ALL WORK WITH OTHER TRADES AS REQUIRED TO AVOID INTERFERENCES BETWEEN TRADES (I.E. BEAMS, CONDUITS, EQUIPMENT, DUCTWORK, ECT.) WORK PERFORMANCE: 1. JOB SITE SAFETY AND WORKER SAFETY IS THE RESPONSIBILITY OF THE CONTRACTOR 2. ARRANGE, PHASE AND PERFORM ALL WORK DURING TIME PERIODS SCHEDULED WITH AND ACCEPTABLE TO THE OWNER BEFORE PROCEEDING, NO ADDITIONAL COMPENSATION WILL BE AUTHORIZED FOR WORK NECESSITATED BY ILL-TIMED, DEFECTIVE, OR NON -CONFORMING WORK. 3. THE CONTRACTOR SHALL ENSURE THAT ALL SYSTEMS OPERATE AS DESIGNED AND/OR REQUIRED AND SHALL REVIEW THEIR OPERATION WITH THE OWNER UPON COMPLETION OF CONSTRUCTION AND TESTING. COMPILE COMPLETE AND UPDATED AS -BUILT DRAWINGS/DOCUMENTS AND ISSUE ONE (1) SET TO THE OWNER. 4. ELECTRICAL WORK SHALL BE ACCOMPLISHED WITH ALL AFFECTED CIRCUITS OR EQUIPMENT DE -ENERGIZED, WHEN AN ELECTRICAL OUTAGE CANNOT BE ACCOMPLISHED IN THIS MANNER FOR THE REQUIRED WORK, THE FOLLOWING REQUIRED WORK, THE FOLLOWING REQUIREMENTS ARE MANDATORY: 4.1. ELECTRICIANS MUST USE AND WEAR FULL PROTECTIVE EQUIPMENT (PPE). WHILE WORKING ON ENERGIZED SYSTEMS IN ACCORDANCE W/ NFPA 70E. THE LEVEL OF PPE SHALL BE DETERMINED BY A COMPUTER GENERATED ARC FLASH CALCULATION PROVIDED AND PAID FOR BY THE CONTRACTOR. THE ARC FLASH DATA SHALL BE PRESENTED WITH THE SUBMITTAL BELOW. 4.2. WORK ON ENERGIZED CIRCUITS OR EQUIPMENT CANNOT BEGIN UNTIL PRIOR WRITTEN APPROVAL IS OBTAINED FROM THE OWNER. 5. ENSURE THAT ELECTRICAL SERVICE REMAINS UNINTERRUPTED FOR OTHER BUILDINGS AND FACTILITIES AT ALL TIMES. PERFORM ALL TEMPORARY WORK NECESSARY TO MAINTAIN CONTINUITY OF ELECTRICAL SERVICE WHEN CONNECTION IS MADE TO EXISTING SYSTEMS. 6. ELECTRICAL EQUIPMENT SHALL NOT BE STORED OUTDOORS. EQUIPMENT SHALL BE STORED IN AN OWNER/E3NGINEER APPROVED MEDIUM AND LOCATION. CODES & STANDARDS: l . PERFORM WORK IN COMPLIANCE WITH THE LATEST EDITION OF ALL APPLICABLE,FEDERAL, STATE AND LOCAL CODES, REGULATIONS AND STANDARDS, TO INCLUDE THOSE LISTED BELOW, ADOPTED BY THE AUTHORITY HAVING JURISDICTION. WHERE DIFFERENCES MAY OCCUR THE MORE STRINGENT REQUIREMENTS SHALL GOVERN. IN CASE OF CONFLICT PROVIDE WRITTEN NOTIFCATION AND OBTAIN A DECISION FROM THE ARCHITECT. 1.1. NFPA 70: NATIONAL ELECTRICAL CODE (2020) 1.2. NFPA 70E: STANDARD FOR ELECTRICAL SAFETY IN THE WORKPLACE (2018) 1.3. NFPA 72: NATIONAL FIRE ALARM CODE (2019) 1.4. NFPA 241: STANDARD FOR SAFEGUARDING CONSTRUCTION, ALTERATION AND DEMOLITION OPERATIONS (2019) 1.5. FBC: FLORIDA BUILDING CODE 8TH ED. (2023) 1.6. OASHA PART 1910: OCCUPATIONAL SAFETY AND HEALTH STANDARDS 1.7. OASHA PART 1926: SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION MATERIALS AND METHODS: 1. MATERIALS AND APPARATUSES SHALL COMPLY WITH ALL APPLICABLE TESTS, RATINGS, SPECIFICATIONS AND REQUIREMENTS OF THE IEEE,NEMA, NFPA, AND UL, SHALL BEAR THE UL LABEL OF APPROVAL AND BE LISTED FOR THE PROPOSED APPLICATION. 2. FINISHED PRODUCTS SHALL BE FACTORY PRIMED AND FINISH COATED WITH THE MANUFACTURER'S PRIME COAT AND STANDARD FINISH UNLESS SPECIFIED OTHERWISE BY THE ARCHITECT. 3. UNLESS OTHERWISE SPECIFIED, UNFINISHED PRODUCTS SHALL BE GALVANIZED, COATED OR PLATED TO RESIST CORROSION. 4. INSTALLATIONS SHALL BE IN ACCORDANCE WITH ALL APPLICABLE CODES, AS RECOMMENDED BY THE MANUFACTURER AND AS CLOSE AS PRACTICABLE TO LOCATIONS INDICATED ON DRAWINGS. 5. INSTALLATIONS SHALL FACILITATE MAINTENANCE AND REPAIR OR REPLACEMENT OF EQUIPMENT COMPONENTS. ACCESS, WORKING SPACES AND CLEARANCES SHALL NOT BE LESS THAN SPECIFIED BY THE NEC FOR ALL VOLTAGES SPECIFIED. 6. PROVIDE APPROVED FIRE STOPPING MATERIALS AT ALL CHASES TO PREVENT DRAFTS. 2 1 ELECTRICAL GENERAL NOTES 7. FIRE RATING: RESTORE FIRE RATING WHERE PIERCING OCCURS THROUGH FIRE RATED CEILINGS OR BETWEEN FIRE RATED WALLS. FIRE STOP MATERIALS SHALL BE AS MANUFACTURED BY 3M COMPANY AND UL LISTED FOR USE IN THE CONSTRUCTION ASSEMBLY IN WHICH IT IS TO BE USED. REFER TO ARCHITECTURAL PLANS FOR LOCATIONS OF FIRE RATED WALLS AND CEILINGS. IDENTIFICATION: 1. INSTALL LABEL TAGS ON ALL WIRE AND CABLE IN JUNCTION BOXES, WIREWAYS AND WIRING GUTTER OF PANELS. TAGS SHALL IDENTIFY WIRE AND CABLE CIRCUIT NUMBER AND/OR EQUIPMENT SERVED AS INDICATED ON DRAWINGS. 2. JUNCTION BOXES SHALL BE LABELED IN A PERMANENT MANNER REFLECTING PANELBOARD/CIRCUIT NUMBER OF BRANCH CIRCUIT WIRING CONTAINED WITHIN. 3. PANEL BOARD DIRECTORIES SHALL BE TYPEWRITTEN, REFLECTING RECORD CONDITION TO INCLUDE CIRCUIT NUMBER, TYPE AND LOCATION OF LOAD. RACEWAYS: 1. RACEWAYS: 1.1. INTERIOR EXPOSED, CONCEALED IN WALLS OR ABOVE CEILINGS: ELECTRICAL METALLIC TUBING (EMT) OR MC CABLE 2. ALL CONDUIT SHALL BE PROPERLY ALIGNED, GROUPED AND SUPPORTED. EXPOSED CONDUIT SHALL BE INSTALLED AT RIGHT ANGLES TO OR PARALLEL TO THE PRINCIPAL STRUCTURAL MEMBERS. PROVIDE SUPPORT A MINIMUM OF 18" FROM BENDS AND OUTLET BOXES AND ON INTERVALS NOT TO EXCEED 8'-0". CONDUIT IS NOT TO SPAN ANY SPACE UNSUPPORTED. ALL CONDUIT SHALL BE SUPPORTED FROM STRUCTURE AND NOT FROM CEILING SUPPORT SYSTEM. 3. PROVIDE NYLON PULL CORD AND LEAVE IN PLACE IN EACH EMPTY CONDUIT. BOXES: 1. ALL BOXES SHALL BE RIGIDLY MOUNTED AND SHALL BE EQUIPPED WITH SUITABLE SCREW FASTENED COVERS, OPEN KNOCK -OUTS OR HOLES IN BOXES SHALL BE PLUGGED WITH A SUITABLE BLANKING DEVICE. CONDUCTORS: 1. UNLESS OTHERWISE INDICATED, ALL BRANCH CIRCUIT CONDUCTORS SHALL BE NO. 12 AWG. BRANCH CIRCUITS RUN OVER 75-FEET IN LENGTH, MEASURING ONE WAY FROM THE FIRE OUTLET OF THE CIRCUIT TO THE PANEL, SHALL BE NO. 10 AWG FOR THE ENTIRE CIRCUIT. 2. CONDUCTORS SHALL BE COPPER WITH THHN/THWN-2 90 C INSULATION, THE FOLLOWING SYSTEMS OF COLOR CORDING SHALL BE STRICTLY ADHERED TO AND SHALL BE CONSISTENTLY FOLLOWED THROUGHOUT: 2.1. GROUND WIRES: GREEN 2.2. GROUNDED NEUTRAL WIRES: WHITE 2.3. 208/120 VOLT, UNGROUNDED PHASE WIRES: BLACK, RED AND BLUE 2.4. 480/270 VOLT, UNGROUNDED PHASE WIRES: BROWN, ORANGE AND YELLOW 2.4.1. WHERE EXISTING BASE BUILDING COLOR CODING DIFFERS FROM COLOR CODING ASSIGNED HERE -IN, USE EXISTING COLOR CODING AS REQUIRED TO MAINTAIN CONSISTENCY. 3. WIRING IN AIR PLENUMS OR PLENUM SPACES NOT IN CONDUIT SHALL BE UL LISTED AS SUITABLE FOR PLENUM USE. 4. CONDUITS AND WIRING PENETRATING RATED FLOORS AND WALLS SHALL BE SEALED TO MAINTAIN FIRE RATING AND INTEGRITY OF SEPARATION. 5. FOR NEW CIRCUITS, MULTIPLE CIRCUITS IN SAME CONDUIT SHALL NOT SHARE NEUTRAL CONDUCTORS. FOR EXISTING CIRCUITS, WHERE REQUIRED BY NEC, PROVIDE AND INSTALL HANDLE TIES ON EXISTING CIRCUIT BREAKERS. 6. INSTALL INSULATED SPRING WIRE CONNECTORS WITH PLASTIC CAPS FOR COPPER CONDUCTOR SPLICES AND TAPS, 10 AWG AND SMALLER. 7. "PUSH -IN" OR "STAB" TYPE CONNECTORS ARE NOT ACCEPTABLE. GROUNDING: 1. THE ELECTRICAL SYSTEMS SHALL BE COMPLETELY AND EFFECTIVELY GROUNDED AS REQUIRED BY THE NEC AND AS SPECIFIED HEREINAFTER. 2. ALL METALLIC RACEWAYS SHALL BE MECHANICALLY AND ELECTRICALLY SECURE AT ALL JOINTS AND AT ALL BOXES, CABINETS, FITTINGS, AND EQUIPMENT. METALLIC RACEWAYS SHALL BE CONNECTED TO A DIRECT GROUND AT THE POINT OF ELECTRICAL SERVICE ENTRANCE AND SHALL BE ELECTRICALLY CONTINUOUS THROUGHOUT THE ENTIRE SYSTEM. 3. ALL GROUND CONDUCTORS SHALL BE INSULATED COPPER UON. 4. ALL RACEWAYS WITH NO. 10 OR 12 AWG PHASE CONDUCTORS FOR RECEPTACLES, LIGHTING FIXTURES AND SIMILAR CIRCUITS (NEW BRANCH CIRCUITS) SHALL BE PROVIDED WITH A PARITY SIZED GREEN EQUIPMENT GROUND CONDUCTOR. GROUND CONDUCTOR SHALL BE INSTALLED IN ENTIRE RACEWAY SYSTEM INCLUDING WALL SWITCHES AND FLEXIBLE CONDUIT TO LIGHT FIXTURES. EQUIPMENT GROUND CONDUCTOR SIZES FOR CIRCUITS WITH PHASE CONDUCTORS LARGER THAN NO. 12 AWG ARE INDICTED ON DRAWINGS. GROUND CONDUCTORS SHALL BE CONNECTED TO GROUND BUS IN PANEL BOARDS. 5. TERMINATE FEEDER AND BRANCH CIRCUIT INSULATED EQUIPMENT GROUNDING CONDUCTORS WITH GROUNDING LUG, BUS OR BUSHING. CONDUCTORS LOOPED UNDER SCREW OR BOLT HEADS WILL NOT BE PERMITTED. 6. INSTALL CLAMP -ON CONNECTORS ON CLEAN METAL CONTACT SURFACES TO ENSURE ELECTRICAL CONDUCTIVITY AND CIRCUIT INTEGRITY. 7. TEST THE GROUNDING SYSTEM TO ASSURE CONTINUITY AND THAT RESISTANCE TO GROUND DOES NOT EXCEED 25 OHMS UNLESS OTHERWISE NOTED. TEST EACH GROUND ROD FOR RESISTANCE TO GROUND BEFORE MAKING CONNECTIONS TO THE ROD; THEN TIE ENTIRE GROUNDING SYSTEM TOGETHER AND TEST FOR RESISTANCE TO GROUND. MAKE RESISTANCE MEASUREMENTS IN NORMALLY DRY WEATHER, NOT LESS THAN 48 HOURS AFTER RAINFALL. MAKE GROUND RESISTANCE MEASUREMENTS WITH A GROUND RESISTANCE TEST METER CALIBRATED WITHIN THE LAST TWELVE MONTHS. 3 I ELECTRICAL GENERAL NOTES SWITCHES & RECEPTACLES: l . RECEPTACLES SHALL BE THE GROUNDING TYPE WITH GROUND CONNECTION MADE THROUGH AN EXTRA POLE WHICH SHALL BE PERMANENTLY CONNECTED TO GROUND CONDUCTOR. 2. CONNECT WIRING DEVICES BY WRAPPING SOLID CONDUCTOR AROUND SCREW TERMINAL. WHEN STRANDED CONDUCTORS ARE USED IN LIEU OF SOLID, USE CRIMP ON FORK TERMINALS FOR DEVICE TERMINATIONS. DO NOT PLACE BARE STRANDED CONDUCTORS DIRECTLY UNDER DEVICE SCREWS. 3. GFCI RECEPTACLES SHALL MEET CURRENT UL 943 REQUIREMENTS WITH AUTO -MONITORING OR SELF -TEST FUNCTIONALITY; IF THE SELF -TEST FUNCTION DETECTS A PROBLEMS, THE UNIT MUST DENY POWER OR PROVIDE VISUAL AND/OR AUDIBLE INDICATION. 4. GFCI RECEPTACLES LOCATED IN DAMP, WET OR EXTERIOR LOCATIONS SHALL BE WEATHER -RESISTANT TYPE TO COMPLY WITH NEC 406.9. 5. RECEPTACLES FOR 20 AMPERE, 120 VOLT APPLICATION SHALL BE SPECIFICATION GRADE, THREE -WIRE, TWO POLE, RATED 20 AMPERES AT 125 VOLTS, PASS AND SEYMOUR OR APPROVED EQUAL. 6. LIGHT SWITCHES SHALL BE SPECIFICATION GRADE, 120/277 VOLT, PASS AND SEYMOUR OR APPROVED EQUAL. 7. PROVIDE WALL PLATES FOR SINGLE AND COMBINATION DEVICES OR TYPES, SIZES AND WITH GANGING AND CUTOUTS AS INDICATED, SELECT PLATES WHICH MATE AND MATCH WIRING DEVICES TO WHICH ATTACHED. CONSTRUCT WITH METAL SCREWS FOR SECURING PLATES TO DEVICES; SCREW HEADS COLOR TO MATCH FINISH OF PLATES, WALL PLATES COLOR TO MATCH DEVICES, COLOR BY ARCHITECT. EQUIPMENT: CIRCUIT BREAKERS SHALL PLUG STYLE BREAKERS LIGHTING FIXTURES: 1. THE CONTRACTOR SHALL FURNISH AND INSTALL COMPLETE IN ALL RESPECTS ALL LIGHTING FIXTURES INDICATED ON THE PLANS. 2. FIXTURES SHALL BE SUPPORTED INDEPENDENTLY FROM CEILING AND SHALL BE PROPERLY AND CAREFULLY ALIGNED. FIXTURE BOTTOMS, EDGES, AND ENDS SHALL BE EVEN AND TRIM SHALL BE SNUG TO SURFACE. THE CONTRACTOR SHALL FURNISH AND INSTALL ALL NECESSARY HARDWARE, ECT, FOR SUPPORT OF FIXTURES AS REQUIRED. 3. RECESSED FIXTURES SHALL BE CONNECTED WITH A MAXIMUM 6 FOOT FLEXIBLE WHIP. 4. FIXTURES SHALL BE CLEAN AND LENSES SHALL BE CLEAR OF FINGERPRINTS. MANUALS: CONSTRUCTION DOCUMENTS SHALL REQUIRE THAT AN OPERATING MANUAL AND MAINTENANCE MANUAL BE PROVIDED TO THE BUILDING OWNER. THE MANUALS SHALL INCLUDE, AT A MINIMUM, THE FOLLOWING: 1. SUBMITTAL DATA STATING EQUIPMENT RATING AND SELECTED OPTION FOR EACH PIECE OF EQUIPMENT REQUIRING MAINTENANCE. 2. OPERATION MANUALS AND MAINTENANCE MANUALS FOR EACH PIECE OF EQUIPMENT REQUIRING MAINTENANCE. REQUIRED ROUTINE MAINTENANCE ACTIONS SHALL BE CLEARLY IDENTIFIED. 3. NAMES AND ADDRESSES OF AT LEAST ONE QUALIFIED SERVICE AGENCY. DOCUMENTATION REQUIREMENTS: THE CONSTRUCTION DOCUMENTS SHALL SPECIFY THAT DOCUMENTS CERTIFYING THAT THE INSTALLED LIGHTING CONTROLS MEET DOCUMENTED PERFORMANCE CRITERIA OF SECTION C405 ARE TO BE PROVIDED TO THE BUILDING OWNER WITHIN 90 DAYS FROM THE DATE OF RECEIPT OF THE CERTIFICATE OF OCCUPANCY. 4 1 LIGHTING FIXTURE &CONTROL SCHEDULE LIGHTING FIXTURE SCHEDULE TYPE PER MANUFACTURER CATALOG NO. MOUNTING QTY WATTS TYPE A EXISTING 2X2 LAY -IN LED EX. 21 EX. EX. B EXISTING 6" LED CAN LIGHT EX. 4 EX. EX. X EXISTING APCH7R APELH2 EX. 3 EX. - ELECTRICAL LEGEND SYMBOL DESCRIPTION DUPLEX RECEPTACLE: 20A, 125VAC *C CEILING DUPLEX RECEPTACLE: 20A, 125VAC {GFCI PROTECTED W/ GFCI BREAKER} DUPLEX RECEPTACLE: 20A, 125VAC {GFCI PROTECTED W/ GFCI BREAKER} ® 208V RECEPTACLE: PER EQUIPMENT {GFCI PROTECTED W/ GFCI BREAKER} Qo Qo ® LED LIGHT FIXTURE (SEE LIGHTING SCHEDULE) EXIT EMERGENCY EXIT SIGN W/ LIGHT EMERGENCY EXIT LIGHT G OCCUPANCY SENSOR (SEE CONTROL SCHEDULE) PP POWER PACK (SEE CONTROL SCHEDULE) VS WALL OCC SENSOR (SEE CONTROL SCHEDULE) 34 MANUAL SWITCH / THREE-WAY TOGGLE SWITCH / FOUR-WAY TOGGLE SWITCH fD DIMMER SWITCH (150D WATTS, U.N.O.) O JUNCTION BOX ZtE QUADRAPLEX RECEPTACLE OUTLET C/L 18" A.F.F. U.O.N 0� DISCONNECT SWITCH - 30A/3/NF LION WALL TELE/DATA OUTLET. PROVIDE MIN. 1" CONDUIT WITH PULL WIRES TO ABOVE CEILING. MTD. 18" A.F.F. U.O.N. ENGINEERING & CONSTRUCTION AUSTIN CONSTRUCTION GROUP 2706 STALLONE DRIVE TAMPA, FLORIDA 33605 (813) 293-8883 FLORIDA PE 48917 192169 - CGC1521407 - CUC1224196 - CFC1430334 - FPC15-4000052 PROJECT INFORMATION: CLIENT: RICHARD KAZBOUR PROJECT NAME: HUNGRY HOWIES RESTAURANT ADDITION PROJECT LOCATION: 5440 GALL BLVD ZEPHYRHILLS, FL 33542 SEAL: GOATS -'*1 ��� ���•••• S E•••` • v� 9 % dam: = • y�o Lo = s���111t11t1111��` FL COA NO. 30178 ENGINEER OF RECORD FL LICENSE NO. TO THE BEST OF THE ENGINEER'S KNOWLEDGE, THE PLANS AND SPECIFICATIONS COMPLY WITH THE APPLICABLE MINIMUM BUILDING CODES REVISIONS: NO. DATE COMMENTS SHEET TITLE: ELECTRICAL NOTES & SCHEDULES SHEET INFORMATION: DRAWN: A.C. SHEET NO. DATE: 7/22/2024 • CHECKED: K.C. 7/22/2024 IjDATE: EOO PROJECT NUMBER: SCALE: INDEX: AS SHOWN I I LIGHTING PLAN SCALE: 1/4"=l'-0" 2 1 PAGE KEY NOTES MARK NOTES 1 SHADED AREA IS OUT OF SCOPE OF WORK. 2 EXISTING WIREWAY AND PANELS A, B, AND C. NO WORK TO BE COMPLETED IN THIS AREA. 3 EXISTING LIFE SAFETY LIGHTING AND SIGNAGE TO REMAIN (TYP.). 4 EXISTING LIGHTS IN AREA TO REMAIN UN -CHANGED (TYP.). 5 EXISTING 2X2 LED LIGHTS TO REMAIN (TYP.). 6 EXISTING CAN LIGHTS TO REMAIN (TYP.). 7 EXISTING 2X2 LED LIGHT TO BE REMOVED. 8 LIGHTING AND POWER INSIDE FREEZER BY MANUFACTURER. 9 NEW ELECTRICAL SERVICE, SEE RISER DIAGRAM. 10 NEW PANEL'P1' -225A, 120/208V, 3P, 4W, 42 CIRCUIT 11 - 12 - 3 1 GENERAL NOTES LIGHTING NOTES: - OCCUPANCY SENSORS SHALL BE DESIGNED TO AUTOMATICALLY TURN OFF LIGHTING WITHIN 20 MINUTES OF ALL OCCUPANTS LEAVING THE SPACE AND BE EQUIPPED WITH MANUAL OVERRIDE SWITCH. - ENERGY -SAVING SENSORS, SWITCHES, TIMERS, OR CONTROLLERS SHALL BE APPROVED AND SHALL NOT COMPROMISE THE CONTINUITY OF ILLUMINATION OF THE MEANS OF EGRESS REQUIRED BY 7.8.1.2 OF THE NFPA 101 LIFE SAFETY CODE. DRAWING GENERAL NOTES: - COORDINATE WITH ARCHITECTURAL & MECHANICAL DRAWINGS FOR ADDITIONAL INFORMATION. - PATCH AND PAINT WALLS AS REQUIRED WHERE DEVICES, BOXES, ECT. ARE REMOVED AND REWORKED. - EXTEND CONDUIT AND CONDUCTORS AS REQUIRED. - COORDINATE NEW ELECTRICAL CIRCUITS IN FIELD WITH OWNER AND CONTRACTOR. LABEL ALL NEW CIRCUITS CORRECTLY. EXISTING CIRCUITS REMOVED TO BE MADE SAFE. ENGINEERING & CONSTRUCTION AUSTIN CONSTRUCTION GROUP 2706 STALLONE DRIVE TAMPA, FLORIDA 33605 (813) 293-8883 FLORIDA PE 48917 192169 - CGC1521407 - CUC1224196 - CFC 1430334 - FPC 15-4000052 PROJECT INFORMATION: CLIENT: RICHARD KAZBOUR PROJECT NAME: HUNGRY HOWIES RESTAURANT ADDITION PROJECT LOCATION: 5440 GALL BLVD ZEPHYRHILLS, FL 33542 SEAL: `` 011111111111��� ♦��� GOATS :Lu :.� °° C? = F`s+ti411iii1��� FL COA NO. 30178 ENGINEER OF RECORD FL LICENSE NO. TO THE BEST OF THE ENGINEER'S KNOWLEDGE, THE PLANS AND SPECIFICATIONS COMPLY WITH THE APPLICABLE MINIMUM BUILDING CODES REVISIONS: NO. DATE COMMENTS SHEET TITLE: ELECTRICAL LIGHTING PLAN SHEET INFORMATION: DRAWN: A.C. SHEET NO. DATE: 7/22/2024 CHECKED: K.C. DATE: 7/22/2024 E1.01 PROJECT NUMBER: SCALE: INDEX: AS SHOWN 1 1 POWER PLAN 2 PAGE KEY NOTES SCALE: 1 /4" = 1'-0" MARK NOTES 1 SHADED AREA IS OUT SCOPE OF WORK. EXISTING WIREWAY AND PANELS A, B, AND C. NO WORK TO BE COMPLETED IN 2 THIS AREA. 3 EXISTING RECEPTACLES IN AREA TO REMAIN. EXISTING RECEPTACLES ALONG EXISTING EXTERIOR WALL TO REMAIN AND BE 4 UTILIZED. RELOCATE AND REMOVE IF NEEDED IN FIELD. CONTRACTOR TO REPLACE EXISTING 20A BREAKER WITH GFCI PROTECTED BREAKER (TYP.) CORDINATE RECEPTACLE LOCATIONS WITH OWNER PRIOR TO INSTALLATION 5 (TYP.) FIELD LOCATE EXACT LOCATION OF WALK-IN FREEZER DISCONNECT. 6 COORDINATE WITH OWNER ON EXACT MODEL PRIOR TO INSTALLING WIRING/CONDUIT. FIELD LOCATE EXACT LOCATION FOR ALL HOOD AND EXHAUST EQUIPMENT 7 PER CAPITEVAIRE PLANS AND SPECIFICATIONS. (TYP.) 8 NEW PANEL 'P1' - 225A, 120/208V, 3P, 4W, 42 CIRCUIT 9 - 10 - 72" PREP TABLE fP-1#16 fP-1#19, PREP TABLE fP-1#18 P I ^&W &I ^&W &I ENGINEERING & CONSTRUCTION AUSTIN CONSTRUCTION GROUP 2706 STALLONE DRIVE TAMPA, FLORIDA 33605 (813) 293-8883 FLORIDA PE 48917 192169 - CGC1521407 - CUC1224196 - CFC 1430334 - FPC 15-4000052 PROJECT INFORMATION: CLIENT: RICHARD KAZBOUR PROJECT NAME: HUNGRY HOWIES RESTAURANT ADDITION PROJECT LOCATION: 5440 GALL BLVD ZEPHYRHILLS, FL 33542 SEAL: GOATS co•; �N •.• .� ui • I gFtd s• sk FL COA NO. 30178 ENGINEER OF RECORD FL LICENSE NO. TO THE BEST OF THE ENGINEER'S KNOWLEDGE, THE PLANS AND SPECIFICATIONS COMPLY WITH THE APPLICABLE MINIMUM BUILDING CODES REVISIONS: NO. DATE COMMENTS SHEET TITLE: ELECTRICAL POWER PLAN SHEET INFORMATION: DRAWN: A.C. SHEET NO. DATE: 7/22/2024 CHECKED: K.C. 7/22/2024 •i'�LDATE: El PROJECT NUMBER: SCALE: INDEX: AS SHOWN i 1 POWER RISER DIAGRAM PANEL NOTES: I0INTERSYSTEM BOND BAR. 2/0 GROUNDING ELECTRODE CONDUCTOR. CONNECT TO 2 - 8' GROUND RODS AND BUILDING FOOTER STEEL NOTE: AVAILABLE FAULT CURRENT TO BE LESS THEN 22K AIC CONTRACTOR TO VERIFY WITH POWER COMPANY PRIOR INSTALLATION. 3" RISE' (3) 3/0 AW( (1) 3/0 AWG NEUTRA METER 2" CONDUIT 1 I 2/0 CU I I 2 1 PANEL SCHEDULE I I I FINISH FLOOR PANEL'P1' 120/208V, 3P, 4W, 225A, MLO, NEMA 1 (LOCATED INDOORS) 22K AIC CKT DESCRIPTION LOAD BKR A B C BKR LOAD DESCRIPTION CKT 1 MUA-1 (FRYERS) 1344 20 2544 20 1200 KITCHEN RECEPTACLE 2 3 1344 2544 20 1200 KITCHEN RECEPTACLE 4 5 1344 2544 20 1200 KITCHEN RECEPTACLE 6 7 MUA-1 (FRYERS) 1373 20 1733 20 360 BREADING RECEPTACLE 8 9 1373 2093 20 720 PEPSI COOLER 10 11 1373 1873 20 500 REFRIGERATOR 12 13 MUA-2 MPU 660 20 1380 20 720 CHEST FREEZER 14 15 660 1020 20 360 PREP TABLE RECEPTACLE 16 17 660 1020 20 360 PREP TABLE RECEPTACLE 18 19 KEF-2 1245 20 1965 20 720 PREP TABLE RECEPTACLE 20 21 1245 1965 720 22 23 1245 1605 20 360 POS STATION 24 25 WALK-IN COOLER 2800 30 2800 SPACE 26 27 2800 2800 SPACE 28 29 2800 2800 SPACE 30 31 SPACE 0 SPACE 32 33 SPACE 0 SPACE 34 35 SPACE 0 SPACE 36 37 SPACE 0 SPACE 38 39 SPACE 0 SPACE 40 41 SPACE 0 SPACE 42 CONNECTED VA 10422 1 10422 9842 SYSTEM VOLTS 120/208, 3P PHASE AMPS 87 1 87 1 82 EQUIPMENT SERVED CONN. LOAD L.F. DEMAND LOAD NOTES LIGHTING 0 125% 0 RECEPTACLES - GENERAL 360 100% 360 AIR CONDITIONING 18531 100% 18531 HEATING 0 100% 0 MISC. NON-CONT. 3735 100% 3735 CONTINUOUS 0 125% 0 KITCHEN EQUIPMENT 12179 65% 7916.35 TOTAL DEMAND LOAD: TOTAL DEMAND AMPS: 30542.35 VA 85 A i SCALE: N.T.S ENGINEERING & CONSTRUCTION AUSTIN CONSTRUCTION GROUP 2706 STALLONE DRIVE TAMPA, FLORIDA 33605 (813) 293-8883 FLORIDA PE 48917 192169 - CGC1521407 - CUC1224196 - CFC 1430334 - FPC 15-4000052 PROJECT INFORMATION: CLIENT: RICHARD KAZBOUR PROJECT NAME: HUNGRY HOWIES RESTAURANT ADDITION PROJECT LOCATION: 5440 GALL BLVD ZEPHYRHILLS, FL 33542 SEAL: ``,0111111111111 f `Fl. •` ' � FL COA NO. 30178 ENGINEER OF RECORD FL LICENSE NO. TO THE BEST OF THE ENGINEER'S KNOWLEDGE, THE PLANS AND SPECIFICATIONS COMPLY WITH THE APPLICABLE MINIMUM BUILDING CODES REVISIONS: NO. DATE COMMENTS SHEET TITLE: ELECTRICAL PANEL & DETAILS SHEET INFORMATION: DRAWN: A.C. SHEET NO. DATE: 7/22/2024 CHECKED: K.C. DATE: 7/22/2024 E201 PROJECT NUMBER: SCALE: INDEX: AS SHOWN 1 1 1 GENERAL NOTES 1 3 1 CONCRETE NOTES (CONTINUED) 1 4 1 DESIGN LOADS 1 5 1 ROOF BRACING AND COLUMN DETAIL SCALE: N.T.S 1. THE STRUCTURAL DESIGN IS BASED ONLY ON THE STRUCTURE IN IT'S COMPLETED STATE. CONTRACTORS AND THEIR SUBS SHALL TAKE WHATEVER PRECAUTIONS THAT ARE NECESSARY IN THEIR OPINIONS TO WITHSTAND ALL HORIZONTAL AND VERTICAL LOADS THAT MAY BE ENCOUNTERED DURING THE CONSTRUCTION, PRIOR TO COMPLETION. 2. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS, ELEVATIONS, AND CONDITIONS AT THE JOB SITE AND BRING TO THE ENGINEERS ATTENTION OF ANY DISCREPANCIES. 3. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL EXCAVATION PROCEDURES, INCLUDING SHORING AND PROTECTION OF ANY ADJACENT PROPERTY, STRUCTURES, STREETS, AND UTILITIES IN ACCORDANCE WITH LOCAL BUILDING CODES. 4. CONSTRUCTION DEAD AND LIVE LOADS SHALL NOT EXCEEDS ACTUAL DESIGN LOADS FOR ANY STRUCTURAL COMPONENT. 5. TEMPORARY BRACING SHALL BE PROVIDED AS REQUIRED TO HOLD ALL COMPONENTS OF THE STRUCTURE IN PLACE UNTIL FINAL SUPPORT IS SECURELY ANCHORED. 6. ALL INSPECTIONS, SPECIAL OR OTHERWISE, THAT ARE REQUIRED BY THE BUILDING CODES, LOCAL BUILDING DEPARTMENT, OR THESE PLANS, SHALL BE DONE BY AN INDEPENDENT QUALIFIED TESTING COMPANY. 7. SHOP DRAWINGS SUBMITTED FOR STRUCTURAL REVIEW SHALL BEAR THE CONTRACTORS APPROVAL STAMP ACCEPTING RESPONSIBILITY FOR DIMENSIONS, QUANTITY AND COORDINATION WITH ALL DISCIPLINES. NO CHANGES OR DEVIATIONS FROM THE CONTRACT DOCUMENTS ARE ACCEPTED UNLESS EACH IS CLEARLY IDENTIFIED AS SUCH, AND EACH IS SPECIFICALLY ACCEPTED OR REJECTED. ANY ACCEPTED CHANGE OR DEVIATION FOR REVISION OF THE PERMITTED CONSTRUCTION DOCUMENTS OR VALUE ENGINEERING COST SAVINGS IS SUBJECT TO A REDUCTION OF THE CONTRACT LUMP SUM. ONLY ONE MARKED UP SET WITH THE STRUCTURAL ENGINEERS COMMENTS WILL BE RETURNED TO THE CONTRACTOR. ALLOW TWO WEEKS TIME FOR SHOP DRAWING REVIEW BY ACG. 8. THE CONTRACTOR SHALL COORDINATE THE STRUCTURAL DRAWINGS WITH THE ARCHITECTURAL, MECHANICAL, ELECTRICAL, PLUMBING, AND CIVIL / SITE WORK PLANS FOR DIMENSIONS AND DETAILS OF THE ITEMS WHICH PENETRATE OR ATTACH TO THE BUILDING STRUCTURE. 9. NO STRUCTURAL MEMBER SHALL BE CUT, NOTCHED OR REDUCED IN STRENGTH. 1 2 1 EARTH WORK NOTES A- QUALITY ASSURANCE: A.1. CODES AND STANDARDS: ACI-301, ACI-315, ACI-318, CRSI, COMPLY WITH APPLICABLE PROVISIONS EXCEPT AS OTHERWISE INDICATED. A.2. OWNER SHALL EMPLOY TESTING LABORATORY TO TEST AND EVALUATE CONCRETE DELIVERED TO AND PLACED AT SITE. THIS TESTING DOES NOT RELIEVE SUBCONTRACTOR OF RESPONSIBILITY OF PROVIDING CONCRETE IN COMPLIANCE WITH CONTRACT DOCUMENTS. A.3. SAMPLING FRESH CONCRETE: COMPLY WITH ASTM C 172, EXCEPT MODIFIED FOR SLUMP TO COMPLY WITH ASTM C 94. a) SLUMP - ASTM C143, ONE TEST FOR EACH LOAD AT POINT OF DISCHARGE. b) AIR CONTENT - ASTM C173, ONE FOR EACH SET OF COMPRESSIVE STRENGTH SPECIMENS. c) COMPRESSIVE TEST SPECIMEN - ASTM C 31, FOUR STANDARD CYLINDERS FOR EACH COMPRESSIVE STRENGTH TEST. MOLD AND STORE CYLINDERS FOR LABORATORY -CURED TEST SPECIMENS EXCEPT WHEN FIELD -CURED TEST SPECIMENS ARE REQUIRED. d) COMPRESSIVE STRENGTH TESTS - ASTM C 39, ONE SET FOR EACH DAY'S POUR EXCEEDING 5 CU. YD. PLUS ADDITIONAL SETS FOR EACH 50 CU. YD. MORE. ONE CYLINDER TO BE TESTED AT 7 DAYS, TWO CYLINDERS TESTED AT 28 DAYS, AND ONE CYLINDER RETAINED IN RESERVE FOR LATER TESTING IF REQUIRED. A.l. REPORT TEST RESULTS TO G.C., ARCHITECT AND OWNER IN WRITING ON SAME DAY TESTS ARE MADE. B) SUBMITTALS: A.l. CONCRETE MIX DESIGN -PER ACI 301. EACH MIX DESIGN SHALL BE LABELED TO INDICATE THE AREA IN WHICH THE CONCRETE IS TO BE PLACED (I.E. FOUNDATIONS, SLAB -ON -GRADE, COLUMNS, ETC. FAILURE TO DO SO WILL CAUSE DELAYS AND/OR REJECTION OF SUBMITTAL. A.2. REINFORCING STEEL FABRICATIONS AND PLACEMENT DRAWINGS - PER ACI 315 C) PRODUCTS: C.1 CONCRETE MATERIALS: a) PORTLAND CEMENT - ASTM C 150, TYPE 1 b) AGGREGATES - ASTM C33 (NORMAL WEIGHT) ASTM C330 (LIGHT WEIGHT). c) WATER - CLEAN, DRINKABLE C.2 REINFORCING MATERIALS: REINFORCING MATERIALS: a) DEFORMED REINFORCING BARS - ASTM A 615, GRADE 60. REINFORCING STEEL TO BE WELDED: ASTM A706 (FOR EMBED., ANCHORS, ETC.) b) WELDED WIRE FABRIC - ASTM A 185 MINIMUM YIELD STRENGTH OF 20,000 PSI. c) FIBER REINFORCEMENTS - ENGINEERED POLYPROPYLENE FIBERS DESIGNED FOR SECONDARY REINFORCEMENTS OF CONCRETE SLABS. C.3 CHAIRS, BOLSTERS, SPACERS, RUNNERS, OTHER SUPPORT DEVICES: CRSI CHAIRS, BOLSTERS, SPACERS, RUNNERS, OTHER SUPPORT DEVICES: CRSI CRSI STANDARDS. C.4 ADMIXTURES: PROVIDE ADMIXTURES THAT CONTAIN NOT MORE THAN 0.1% CHLORIDE IONS. ADMIXTURES: PROVIDE ADMIXTURES THAT CONTAIN NOT MORE THAN 0.1 % CHLORIDE IONS. PROVIDE ADMIXTURES THAT CONTAIN NOT MORE THAN 0.1 % CHLORIDE IONS. 1) AIR -ENTRAINING ADMIXTURES: ASTM C260 2) WATER -REDUCING, RETARDING, AND ACCELERATING CHEMICAL ADMIXTURES: ASTM C 494 C.5 RELATED MATERIALS: a) VAPOR RETARDER - CLEAN 10 MIL THICK POLYETHYLENE ASTM E 154 b) ABSORPTIVE COVER - BURLAP CLOTH MADE FROM JUTE OR KENAF, WEIGHING APPROXIMATELY 9 oz PER SQ. YD., COMPLY WITH AASHTO M 182, CLASS 2. c) MOISTURE - RETAINING COVER - WATERPROOF PAPER, POLYETHYLENE FILM, OR POLYETHYLENE -COATED BURLAP, COMPLYING WITH ASTM C 171. d) MEMBRANE - FORMING CURING COMPOUND - ASTM C 309, TYPE 1. e) EVAPORATION CONTROL - MONOMOLECULAR FILM -FORMING COMPOUND APPLIED TO EXPOSED CONCRETE SLAB SURFACES FOR TEMPORARY PROTECTION FROM RAPID MOISTURE LOSS. f) WATER STOPS: FLAT DUMBBELL OR CENTER BULB TYP, SIZE TO SUIT JOINTS, OF EITHER RUBBER OR PVC. g) NON SHRINK GROUT - 7,000 PSI CRD C 621 D. MIX DESIGN: D.1 PROPORTION MIXES COMPLYING WITH MIX DESIGN PROCEDURES SPECIFIED I ACI 301. D.2 PROVED READY -MIX CONCRETE COMPLYING WITH ASTM C 94. D.3 ALL CONCRETE SHALL BE NORMAL WEIGHT (139 PCF - 150 PCF), WITH MIXES DESIGNED TO MEET THE FOLLOWING CRITERIA FOR USE IN VARIOUS ELEMENTS OF THE STRUCTURE AS FOLLOWS: STRUCTURAL ELEMENT COMP (PSI) MAX. AGGREGATE SIZE SLUMP FOOTING, FOUNDATION WALLS 3000 1 2 4 +/- 1" SLAB ON GRADE 3500 1 2" 4 +/- 1" COLUMNS, BEAMS 4000 1 4 +/- 1" ELEVATED SLAB 3500 1 4 +/- 1" FILLED CELL GROUT 2500 3/8" 8" TO 11" NOTE: 1. WATER/ CEMENT RATIO = .58 MAX. (NON -AIR -ENTRAINED) WATER/ CEMENT RATIO= .46 MAX. (AIR ENTRAINED) 2. PEA ROCK PUMP MIXES NOT PERMITTED 3. ELEVATED SLABS ON METAL DECK TO USE LIGHT WEIGHT AGGREGATE (115 PCF MAX) E. EXECUTION: El. HOT WEATHER COMPLY WITH ACI 305 E2. REINFORCING STEEL PLACEMENT TO COMPLY WITH ACI 315, AND CRSI. a) WHERE SPLICE LENGTHS ARE NOT SPECIFIED, USE 48 BAR DIAMETER IN MASONRY AND 40 BAR DIAMETERS IN CAST CONCRETE. b) REINFORCING STEEL SHALL NOT BE TACK WELDED FOR ANY REASON. WELDED REINFORCING STEEL SPLICES ARE NOT PERMITTED. c) LAP ALL WELDED WIRE FABRIC A MINIMUM DISTANCE OF ONE CROSS WIRE SPACING PLUS 2 INCHES. d) ALL REINFORCING STEEL SHALL BE SUPPORTED ON STANDARD ACCESSORIES, HELD RIGIDLY AND ACCURATELY IN PLACE, AND PROTECTED AGAINST DISPLACEMENT BEFORE AND DURING PLACEMENT OF CONCRETE, SUPPORTING ACCESSORY LEGS THAT REST ON CONCRETE SURFACES THAT WILL BE EXPOSED IN THE FINISHED STRUCTURE SHALL BE FABRICATED ON STAINLESS STEEL. E3. CONCRETE COVER: CONCRETE COVER:: a) FOOTINGS AND FOUNDATION PADS PLACED AGAINST THE GROUND = 3". b) CONCRETE SURFACE AFTER REMOVAL OF FORMS EXPOSED TO WEATHER OR GROUND: No. 5 BAR or SMALLER =1 1\2" No. 6 BAR or LARGER = 2" c) CONCRETE NOT EXPOSED TO WEATHER OR GROUND: SLABS AND WALLS = 3/4" BEAMS AND GIRDER TIES = 1 1 \2" COLUMN TIES = 1 1 \2" E4. FOUNDATION REINFORCEMENTS SHALL BE CONTINUOUS WITH CORNER BARS (48 x BAR DIA. EACH LEG) AT INTERSECTIONS AND CORNERS, ONE FOR EACH EACH HORIZONTAL BAR. E5. PROVIDE KEYED CONSTRUCTION JOINTS (KCJ) IN EARTH OR FILL SUPPORTED SLABS AT LOCATIONS NOTED ON PLAN. PROVIDE CONTROL JOINTS (CJ) AT ALL LOCATIONS NOTED ON PLAN. IF 'CJ' IS SAW CUT, THE CUT MUST BE MADE AS SOON AS POSSIBLE, BUT NOT LATER THAN 18 HOURS AFTER THE POUR UNLESS OTHERWISE NOTED ON PLAN - PROVIDE CJ AT SPACINGS NOT TO EXCEED DIMENSIONS IN TABLE BELOW - PATTERNS SHALL BE APPROXIMATELY SQUARE WITH A RATIO OF LONG SIDE TO SHORT SIDE NOT GREATER THAN 1.5 TO 1 SLAB THICKNESS (IN) CJ SPACING (FT) 4 12 5 13 6 14 7 15 E6. SLAB FINISHES AS FOLLOWS: a) EXPOSED TO VIEW AND SLAB SURFACES TO BE COVERED WITH RESILIENT FLOORING, CARPET, PAINT, OR OTHER FILM, TO BE FINISH COATING SYSTEM, FLOAT AND TROWEL FINISH. b) SURFACES TO BE COVERED WITH CERAMIC TILES, TROWEL FINISH FOLLOWED IMMEDIATELY WITH FINE BROOMING TO SLIGHTLY SCARIFY SURFACE. 1. WIND DESIGN DATA: ULTIMATE WIND SPEED, VULT= 140 MPH NOMINAL DESIGN WIND SPEED, VASE= 108 MPH RISK CATEGORY = II WIND EXPOSURE = C Kzt = 1.00 Kd = 0.85 Ke = 1.00 COMPONENTS AND CLADDING PRESSURES = SEE TABLE BELOW 3. FLOOD DESIGN DATA: FLOOD HAZARD ZONE DESIGNATION = X ZONE POSITIVE WIND PRESSURE P+ (psf) NEGATIVE WIND PRESSURE P- (psf) 4 38.0 - 42.0 5 38.0 - 51.0 APPROVED PRODUCTS LIST CATEGORY SUB -CATEGORY MANUFACTURER APPROVAL # WINDOWS PASS -THROUGH READY ACCESS FL5102.3 r- - - - - - - - - - - - - - - - - - - - - - - i I I I I THE BOTTOM PROPOSED ROOFTOP UNIT MUA-1 EXISTING ROOF SYSTEM ENGINEERING & CONSTRUCTION AUSTIN CONSTRUCTION GROUP 2706 STALLONE DRIVE TAMPA, FLORIDA 33605 (813) 293-8883 FLORIDA PE 48917 192169 - CGC1521407 - CUC1224196 - CFC 1430334 - FPC 15-4000052 PROJECT INFORMATION: CLIENT: RICHARD KAZBOUR PROJECT NAME: HUNGRY HOWIES RESTAURANT ADDITION PROJECT LOCATION: 5440 GALL BLVD ZEPHYRHILLS, FL 33542 SEAL: GOATS,�����i�� o ••.•�,� S E •'•• • Q �G SzN d • t.\O' : W 0 i FL0 0�(,`� • ••..•• FL COA NO. 30178 ENGINEER OF RECORD FL LICENSE NO. TO THE BEST OF THE ENGINEER'S KNOWLEDGE, THE PLANS AND SPECIFICATIONS COMPLY WITH THE APPLICABLE MINIMUM BUILDING CODES REVISIONS: NO. DATE COMMENTS SHEET TITLE: STRUCTURAL NOTES & DETAILS SHEET INFORMATION: DRAWN: A.C. SHEET NO. DATE: 7/22/2024 CHECKED: K.C. DATE: 7/22/2024 soel PROJECT NUMBER: SCALE: INDEX: AS SHOWN