Loading...
HomeMy WebLinkAbout5542 Gall Blvd (4)P c>� OPEN AREA THE CLIENT UNDERSTANDS THAT THE DESIGNER CARRIES NO LIABILITY INSURANCE AND THEREFORE AGREES TO HOLD HARMLESS, IDEMNIFY, AND DEFEND DESIGNER FROM ALL CLAIMS, LOSSES AND EXPENSES (INCLUDING REASONABLE ATTORNEY FEES) ARISING OUT OF OR RESULTING FROM THE PROJECT. THE DESIGNER WILL IN GOOD FAITH ATTEMPT TO PROVIDE ERROR FREE CONSTRUCTION DRAWINGS, BUT IN THE EVENT ERRORS OCCUR THE DESIGNER WILL NOT BE LIABLE FOR COST OF REPAIRS OR DELAY TO THE CONSTRUCTION TOP OF EXISTING MASONRY WALL OF RETENTION AREA APPROXIMATE IS" ABOVE PARKING LOT XISTINCx � GAR WASH MASONRY BUILDING EX16TING RETENTION AREA APPROXIMATE -12" DEEP EXISTING PLANT AREA EDGE OF THE EXISTING CONCRETE PARKING LOT EX16TINCB FLOOR PLAN 1/411 _ 11 011 — -\— —\ —\— —\7- -\ —\— —\�—\ —\\7- —\ —\ —\ —\7- —\�— CAR IUASN MASONRY BUILDING \ 'k' 11\1 \ \ \ \ \ \ \ JAA B AT. TOP .OF SLAP AT THIS A f. . TO'SAME HEIGHT• AS ,RETgININCz ' : : � ?� : : ' : : ' : : ' : ,i PEN AREA . .. ..... . .. ... .. i.. I �.. . . .. . .. NEW O Cfi� OOR 'R OVER R rt, ON ,4R �4 .. .. ... .. ... .. ... ... ... .. ... .. .r`. .. ... ... .. ... .. ... ... .. ... .. ... .. ... ... ... .. ... .. �'...?-. .. ' q y'' . r,� .. ... .. ... ... .. f^� . ... ... ... A�•�/// .. , .. .. - . t ., 1. '. .. ... .. ... .. . .. ... .. ... .. ... .. .. CUT 6" TO 12" FROM TOP OF EXISTING MASONRY RETAINING WALL TO ALLOW FOR CONCRETE TO POUR OVER TOP OF WALL AS SHOWN, (VIF) EDGE OF THE EXISTING CONCRETE PARKING LOT NEW FLOOR PLAN 1/411 _ 11 011 REMOVE EXISTING PLANT AREA AND POUR NEW CONCRETE THAT WILL SLOPE UP FROM EXISTING PARKING LOT GRADE TO NEW CONCRETE AREA. THERE WILL BE APPROXIMATE 10" DIFFERENCE. TOP OF WALL AS THIS LOCATION 15 FLUSH WITH CONCRETE PARKING LOT n f 1COD r d �i i�'r '' T f t.� T TYR r, 04 Atv HILLS ARKAY ENGINEERING INC. STRU RAIL ENGINEERS e r RIGHA D L, 1<1POEY P.E, FLORIDA LICTENSE NUMBER 31296 I HERBY CERTIFY THAT THESE PLANS AND SPECIFICATIO NS WERE PREPARF_D BY ME OR UNDER MY DIRECT SUPERVISION ARE IN COMPLIANCE WITH CHAPTER 16, SECTION 1609 0 F THE FLORIDA BUILDING CODE 2001 FOR 120 MPH (3 SECOND GUST) WIND ZONE - 100 MPH FASTEST SPEED AND THE ENTIRE 2001 FLORIDA BUILDING CODE AND 200E SUPPLEMENTS \R v O a NQ V QO WooO�� M P �C4�MZ O rr C-4 �WM cos apMD M cQ V NJ Q) :3 L d1-g 0 �- - fa p Ul � o28-- co 00-0 W �Qu-J Ul n, QQQ��`QQQLx{{{ -- (La)QL z p � O O ao M O O z d u.i O Q Q O u- U� �a V ZZ O� U� �a L PIG 1 OF 3 ARKAY * /31.5^4 I a IT 011 ALL COLUMNS AT BUILDING TO HAVE ADDITIONAL FOOTINGS FAD, SEE CUT SECTION DETAIL CONCRETE STOPS HERE, FORM END WITH CURB AS SHOWN ON FLOOR PLAN ALL COLUMNS AT RETAINING WALL TO SET ON TOP OF EXISTING FOOTINGS, SEE CUT SECTION DETAIL 11,011 \\EXISTING\\\\\ CAR WASH MASONRY BUILDING \'�\ \\k 1 \0 1 \ \ \ \ \ \ \ 1111 IIIIIIIIIUL'Im I I I I I I I I I I I I 1-1-LI-IJ L I I I I I I I I I I I LI I I I I 11. 1. 1 -111111111 1.11111.111 ilaaL III 11111 1 1111111 Iij I i I i ! i i I I I I I I I i I I I IIIII I I I I [1j]= I I I I I III I I I I I I I I I I I I I I I I I I I F— i---------- f-------------------- f ------------------- i---I------------------ f----------------- --- f---------------------,-- if -------------------- ------------------- iE ---------------_ — — — tt ■ 1 1 1 I I I I I I - 1 ` - - - - L - - - j ` - - - - - - - - j- POWER STEEL LINTELS WITH DOUBLE ROW 8"X16" KNOCK OUT LINTEL BLOCK WITH (1) 1*5 REBAR EACH COARSE POURED 0 SOLID WITH 3000 PSI CONCRETE (TYP) 9' 4II 91 411 91 4II 91 411 91 111 c3I 411 el 4 11 1B1 11 r Q11 1 I 1 I I I I I I I I 1 I I I 1 1 1 1 I I I I 1 I I I I 1 I 1 I 1 ■ ■ I I ■ ■ 1 ■ — — — — — — — — — —7- — — — — 1— — — — -7 1 1 1 ■ I I 1 I 1 I I 1 I I 1 I I 1 I 1 1 1 1 I 1 1 I 1 I 1 1 I I I I 1 I 1 1 I POWER STEEL LINTELS WITH DOUBLE ROW 8"X16" KNOCK OUT LINTEL BLOCK WITH = (1) "5 REBAR EACH COARSE POURED Q SOLID WITH 3000 PSI CONCRETE (TYP) _ 1— ■ ■ — — — — �— — — — — — — — 1� — — — — — — — — — — — — — — — — — — — — — — — — — — — — ■ ■ ■ ■ ■ Nl .. .. ... .. ... .. ... .. ... .. ... .. ... .. CUT 8" TO 12" FROM TOP OF EXISTING MASONRY RETAINING WALL TO ALLOW FOR CONCRETE TO POUR OVER TOP OF WALL AS SHOWN, (VIF) EDGE OF THE EXISTING CONCRETE PARKING LOT - - 117711�- -\ -\ -\ -� -\ -\7 -\17 -\ -\ -\ - 8"X16" BLOCK COLUMNS WITH (1) 05 VERTICAL REBAR EACH CELL FROM 12"X3ro"X36" CONCRETE PAD BELOW WITH (4) "5 REBAR EACH WAY. SEE CUT SECTION DETAIL FOR HEIGHTS OF COLUMNS 1=OUNDATION PLAN 1/411 _ 11 p11 111111® REMOVE EXISTING PLANT AREA AND POUR NEW CONCRETE THAT WILL SLOPE UP FROM EXISTING PARKING LOT GRADE TO NEW CONCRETE AREA. THERE IS APPROXIMATE 8" DIFFERENCE. CAR WASH MASONRY BUILDINCx � \ i i 111111KINK IN roXro-W2.-BXW2.c3 WIRE MESH ----------------- IIIOK 17 5AR JOISTO 24 OC WITH - WITH 4" 4000 f=SI CONCRETE REINFORCE WITH roX(o-W2,cJXW2.'3 WIRE MESH ------------ 5AfR J016T PLAN 1/411 = 11 011 t THE CLIENT UNDERSTANDS THAT THE DESIGNER CARRIES NO LIABILITY INSURANCE AND THEREFORE AGREES TO HOLD HARMLESS, IDEMNIFY, AND DEFEND DESIGNER FROM ALL CLAIMS, LOSSES AND EXPENSES (INCLUDING REASONABLE ATTORNEY FEES) ARISING OUT OF OR RESULTING FROM THE PROJECT, THE DESIGNER WILL IN GOOD FAITH ATTEMPT TO PROVIDE ERROR FREE CONSTRUCTION DRAWINGS, BUT IN THE EVENT ERRORS OCCUR THE DESIGNER WILL NOT BE LIABLE FOR COST OF REPAIRS OR DELAY TO THE CONSTRUCTION ARKAY ENGINEERING INC. STRUCTURAL ENGINEERS RICHARD L. KIVDEY FLORIDA LICE!dSE NUMBER 31296 I HERBY CERTIFY TART THESE PLANS AND SPECIFICATIO NS WERE PREPARED" BY ME OR UNDER MY DIRECT SUPERVISION ARE IN COMPLIANCE WITH CHAPTER 16, SECTION 1603 O F THE FLORIDA BUILDING CODE 2001 FOR 120 MPH (3 SECOND GUST) WIND ZONE - 100 MPH FASTEST SPEED AND THE ENTIRE 2001 FLORIDA BUILDING CODE AND 2009 SUPPLEMENTS y Z W w 11ww v, Q WcoO� � M O�W � Lu W QMQM WH�Lu W O 1- �Wc� crj 2o° Z!l A tL L � L Z u Ow B1� lU A o t 8 (y- Ul�o� �b H z 0 Q cri � O z � o Q Q 1L U3: � Q hl � U� z z o� U� Q � uj id FIG 2OF3 o� EXISTING WALL OF BUILDING WITH 05 VERTICAL RODS iv 2' 4" OC WITH CELLS POURED SOLID DRILL 4" INTO EXISTING FOOTINGS AND EPDXY (3) 05 REBAR AS SHOWN THE CLIENT UNDERSTANDS THAT THE DESIGNER CARRIES NO LIABILITY INSURANCE AND THEREFORE AGREES TO HOLD HARMLESS, IDEMNIFY, AND DEFEND DESIGNER FROM ALL CLAIMS, LOSSES AND EXPENSES (INCLUDING REASONABLE ATTORNEY FEES) ARISING OUT OF OR RESULTING FROM THE PROJECT. THE DESIGNER WILL IN GOOD FAITH ATTEMPT TO PROVIDE ERROR: FREE CONSTRUCTION DRAWINGS, BUT IN THE EVENT ERRORS OCCUR THE DESIGNER WILL NOT BE LIABLE FOR COST OF REPAIRS OR DELAY TO THE CONSTRUCTION =^1.7 I IIYC: rVV 111`71.;0 11 411 WITH (2) #5 REBAR 31 OII A5 5UILT RETENTION CUT 6ECTION N, T. S, EX16TINC-4 FOOTINGS AND WALL INFORMATION DETERMINED FROM 48 IBUILT DRAWING5 FROM LOCAL 5UILDING DEPARTMENT s • 8K1 BAR JOIST -9 24" OC WITH VULCRAFT I,OC26 WITH 4" 4000 PSI CONCRETE REINFORCE WITH foX6-W2.9XW2.9 WIRE MESH, 114"X4"X6" STEEL PLATE WITH 518"X6" ANCHOR BOLT WELDED TO BOTTOM TO SET IN TOP OF WALL, WELD BAR JOIST TO PLATE AT EACH SIDE WITH I" PUDDLE WELD 8"X16" BLOCK COLUMNS WITH (1) "5 VERTICAL REBAR EACH CELL POURED SOLID WITH 3000 PSI CONCRETE FROM FOOTING PAD BELOW BOTTOM OF RETENTION AREA 12"X36"X36" 3000 PSI CONCRETE PAD BELOW WITH (4) 05 REBAR EACH WAY, m EXISTING FOOTINGS WITH (2) #5 REBAR • A\-TAC I DF I 0 jtj517S \A](V SKI BAR JOIST mat 24" OC WITH VULCRAFT 1,OC26 WITH 4" 4000 PSI CONCRETE REINFORCE WITH 6Xro-W2.SXW2.S WIRE MESH I14"X4"X6" STEEL PLATE WITH 5/8"X6" ANCHOR BOLT WELDED TO BOTTOM TO SET IN TOP OF WALL, WELD BAR JOIST TO PLATE AT EACH SIDE WITH 1" PUDDLE WELD POWER STEEL LINTELS WITH DOUBLE ROW 8"X16" KNOCK OUT LINTEL BLOCK WITH (1) #5 REBAR EACH COARSE POURED SOLID WITH 3000 PSI CONCRETE (TYP) 8"X16" BLOCK COLUMNS WITH (U "5 VERTICAL REBAR EACH CELL FROM PAD BELOW �I o 10"X16"X36" 3000 PSI CONCRETE 31 On PAD WITH (3) "5 REBAR EACH WAY NEW RETENTION CUT &ECTION N.T.S. 8"X16" BLOCK COLUMNS WITH (1) 1*5 VERTICAL REBAR EACH CELL POURED 50LID WITH 3000 PSI CONCRETE. DRILL 6" INTO EXISTING FOOTINGS AND EPDXY EACH "5 REBAR u :ETE REA JITH "5 WAY CUT 8" TO 12" FROM TOP OF EXISTING MASONRY RETAINING WALL TO ALLOW FOR CONCRETE TO POUR OVER TOP OF WALLAS SHOWN, (VIF) 4!5 FEW X' C44-r- (-rff �- EXISTING CONCRETE �— PARKING LOT AREA REMOVE EXISTING PLANT AREA AND POUR NEW CONCRETE THAT WILL SLOPE UP FROM EXISTING PARKING LOT GRADE TO NEW CONCRETE AREA. THERE IS APPROXIMATE 8" DIFFERENCE. EXISTING RETAINING WALL WITH "5 VERTICAL RODS 6 2' 0" OC WITH ALL CELLS OF WALL POURED SOLID EXISTING FOOTINGS WITH #5 REBAR 12" OC EACH WAY ARKAY ENGINEERING INC. STRU RAL E'O'NEERS RICHAF?D L. KODEY P.E. FLORIDA LICEN6E NUM1,3ER 312S& I HERBY CERTIFY" THAT THESE PLANS AND SPECIFICATIO NS WERE PREPARED Br ME OR UIIDER MY DIRECT SUPERVISION ARE IN COMPLIANCE WITH CHAPTER 16, SECTION 1609 O F THE FLORIDA BUILDING CODE 2001 FOR 120 MPH (3 SECOND GUST) WIND ZONE - 100 MPH FASTEST SPEED AND THE ENTIRE 2001 FLORIDA BUILDING CODE AND 200E SUPPLEMENTS �y 2 ^y W wy ZWMc�Q O > M V DO WooOtQi, � M �:svN W 2oNpQM W W W O r � � M z L &L � o L z 03 0 Uzl� Qo�ui LU Q&L OA) a z 0 a � O 4 0 � o � � � z Q Q O 1L U� `uj Z U� QQ Q� @Q i PG 3OF3 ,aRKAY # /31D�