HomeMy WebLinkAbout6512 Gall Blvd (5)STRUCTURAL NOTES W Q 0 U) N� it W a Ld 03 �r �o J 3 -6 a oZ < oZ �o �w o= w 0 < K° QLU ,W L � 0 �o � U �o �o �Cf CL mW -w sm : 0 so S Z o� fJ Z �U) �W �Z o� Z Ill dl < 00 wo � a O `-' oaf UJ W o a w T LL Z S o H 1. GOVERNING CODES: This design is based on the following codes: A. Florida Building Code, 2004 with 2006 additions. B. Building Code Requirements for Structural Concrete ACI 318 (2002 EDITION) C. Specification for the Design, Fabrication, and Erection of Structural Steel for Building, ASD Design method. D. Structural Welding Code D1.1 II. DESIGN LOADS: A. Wind load based on using the Florida Building Code methods of calculation for wind pressures and the following factors: 1. Mean Roof Height of less than 30'-0" 2. Wind speed of 110 MPH. 3. Exposure Category'B'. 4. Importance factor of 1.0 (Building Category II). 5. Internal Pressure Coefficient of +/- 0.18 ("Enclosed" building). 6. This building is NOT IN A WIND BORNE DEBRIS REGION as defined by Florida Building Code. B. Roof live load of 20 PSF with allowable load reductions based on area as outlined in the Florida Building Code. Roof drainage shall conform to the requirements of the Florida Plumbing Code Section 11. Overflow drains shall be located so that, in the event of the primary drains being blocked, no more than 3-1/2" of water can accumulate before entering the overflows. C. Roof dead load of 20 PSF. D. Allowable soil bearing of 2,000 PSF. III. DISCREPANCIES BETWEEN DRAWINGS & EXISTING CONDITIONS: These drawings were prepared based on field data gathered during the design process. However, as the demolition of the existing structure allows for better views of the existing structure, there may be discrepancies between the drawings & the actual conditions. These discrepancies should be brought to the attention of the architect immediately. Please confirm all dimensions to the existing structure before ordering, purchasing, or installing any new work. IV. SHOP DRAWINGS: A. Contractor shall allow for (10) ten business days for shop drawing review. B. Our office will accept shop drawings in both electronic and paper format. C. If the Shop Drawings are in a paper format, we will require (3) three copies minimum shall be submitted with (1) one copy to be retained by our office. D. If the Shop Drawings are in electronic format the following shall apply: 1. The only accepted electronic format shall be Adobe PDF format. 2. If the electronic files are e-mailed to our office, the e-mail address is Mail@Adams-Engineers.com and a faxed transmittal shall be sent to our office informing us of that the drawings were sent to our office by e-mail. 3. If the electronic files are sent to our office as copied on a CD or DVD a transmittal shall be included in the package. 4. The reviewed shop drawings shall be returned to Project Architect (or directed party) in either electronic format or paper format as directed by Client. If paper format is requested, it shall be blackline copies with any comments generated by our office in contrasting font or "boxed". Additionally we will invoice for the printing costs associated with the production of these drawings based on the prevailing prints costs in Tampa Bay Area. V. DRAWINGS AND SPECIFICATIONS: A. Do not scale these drawings for dimensions not given. Advise Project Architect of any conflicts between these drawings and the Architectural drawings. Verify all field conditions and confirm column locations in respect to architectural wall alignment prior to the start of work. B. These drawings are to be used in combination with the architectural, mechanical, plumbing and civil drawings. Refer to these other drawings for details that relate to structural components. C. These construction documents have been prepared from the most complete information available to the engineer. All data on existing construction conditions are approximate & shall be verified prior to commencing work. D. The contractor shall comply with the manufacturer's instructions & recommendations to the extent -printed information are more detailed or stringent than the requirements contained in the plans. E. The plans show the location of all fixtures & equipment & are intended to convey the general intent of the work in scope & layout. They are not intended to show in minute detail every & all of the accessories intended for the purpose of execution of the work, but it is understood that such details are part of this work. F. The Contractor shall perform no portion of the work at any time without Contract Documents or, where required, approved shop drawings, product data or supplemental details for such portion of the work. G. The Contractor is responsible for means and methods of construction to ensure the safety of the building until the structural system is completed. The structural system is unstable until all connections have been made and all concrete has reached the minimum design strength as specified in these drawings. H. The use of electronic files or reproductions of these contract documents by any contractor, subcontractor, erector, fabricator or material supplier in lieu of preparation of shop drawings signifies their acceptance of all information shown hereon as correct, and obligates themselves to any job expense, real or implied, arising due to any error that may occur hereon. VI. CONCRETE: A. Concrete strength requirement: 1. 3,000 psi: Foundations, slab -on -grade, sidewalks B. Maximum Slump: 4" (+/- 1 ") for all concrete, except use 8"-11" for filling cells in block. Fly ash, if used, shall not exceed 20% by weight of total cementitious content. Slump limits shall be strictly adhered to. C. The concrete shall contain the maximum size aggregate permitted by ACI Code up to 3/4" maximum. The guidelines for maximum aggregate size are not greater than 1/5 the narrowest opening in the forms, and/or 1/3 the depth of the slab. D. Concrete formwork: Concrete formwork shall be in a clean condition for use as finished surface forms. Forms shall not be removed until the concrete is of sufficient strength to support its own weight and proposed construction loads. E. Minimum Concrete Cover 1. Concrete cast against and permanently exposed to earth = 3 inches. 2. Concrete exposed to earth or weather = 1-1/2 inches 3. Concrete not exposed to earth or weather = 3/4 inches F. Concrete must be batched, mixed, and transported in accordance with The Specifications for Ready -Mixed Concrete ASTM C94. Concrete shall be placed with -in 90 minutes of batch time. G. A qualified testing laboratory shall be retained to perform the following concrete tests. The concrete samples shall be taken in accordance with ASTM C 172 and specimens made in accordance with ASTM C 31. Testing of specimens shall be in accordance with ASTM C 39. Each test shall consist of a minimum of 3 cylinders. One sample shall be tested at 7 days, and one at 28 days. Reports showing the results of testing shall be submitted at the earliest possible date following testing and shall indicate date, time, weather conditions (temperature), composition of mix (per delivery ticket), slump, location of concrete, compressive strength, type of break, and other pertinent information helpful in the evaluation of the tests. All tests shall be sequentially numbered for easy identification. The concrete test cylinders shall be taken for each type of class of concrete and not less than once per daily pour, nor less than the following intervals: 1. Footings and sidewalks: One set of samples for each 100 cubic yards of concrete placed, nor less than once per daily pour. 2. Floor slabs: One set of samples for each 50 cubic yards of concrete placed, nor less than once per daily pour. 3. Concrete beams & Columns: One set of samples for each 50 cubic yards of concrete placed, nor less than once per daily pour. 4. Tilt wall panels: One set of samples for each 50 cubic yards of concrete placed, nor less than once per daily pour. H. Expansion and Contraction Joints: Floor (contraction) joints shall be saw cut or prefabricated at a maximum spacing of 2 to 3 times the slab thickness in feet (i.e. 8'-12' o/c for a 4" thick slab). These contraction joints shall be approximately 1/8" wide and extend to a minimum depth of 1/4 the slab thickness. A 1/4" perimeter expansion (isolation) joint shall be used at floors adjoining walls and around all columns. These isolation joints shall be formed by installing an asphalt impregnated fiber sheet that extends the entire thickness of the slab. VII. CONCRETE REINFORCEMENT: A. Reinforcing steel bars shall be Grade 60 (60 KSI ASTM A615) steel and tied with drawn steel wire. B. Welded Wire Fabric shall conform to ASTM A185. C. Placement of reinforcing steel shall be as shown on plans and per the "Manual of Standard Practice for Detailing Reinforced Concrete Structures", ACI 315 manual on placing steel reinforcing. D. Provide minimum lap splice of 48 bar diameters, but not less than 18 inches, for all reinforcing bars, unless noted otherwise. Stagger splices in adjacent bars at least 24 inches, except in beams and columns. E. In wall footings, grade beams and bond beams, provide bent bars at corners and intersections of the same number and size as the straight bars. F. Provide for an allowance of 1 % of the total reinforcing steel for the project to be fabricated and placed during progress of the work as may be directed by the Structural Engineer, in addition to the reinforcing steel indicated on the drawings. A credit for any unused quantity of this material at the end of the project shall be given to the Owner. VIII. CAST IN PLACE CONCRETE: A. The concrete supplier shall provide mix designs of all concrete used in structural applications. B. When pouring against earth, the embankment shall be wetted first and all pours on direct sun days will be misted at least twice following initial set. Isolation joints shall be provided at all columns and expansion felt at the perimeter of the slab. C. Finish on the surface of floor shall be machined troweled followed by hand finishing as required. D. Exterior walks and parking areas to be light brushed finished. E. Curing of concrete shall be in accordance with ACI 318. IX. FOUNDATIONS: A. Maximum soil bearing pressure used for design ....... 2000 PSF B. Notify Engineer if footing excavation reveals unsuitable or unstable soils, or materials or conditions not anticipated in the area. C. Concrete placement shall occur immediately after footing excavation & placement of reinforcing steel. Any freestanding water shall be pumped out of footing excavation prior to concrete placement D. A qualified testing laboratory shall be retained to perform the following minimum in -place density tests: This suggested testing shall be used in absence of a testing program suggested by a soil engineer as contained in a soil report performed for this project. 1. One density test for each 2,500 square feet of compacted subgrade. 2. One density test at each column. 3. One density test per 50 feet of wall footing. X. STRUCTURAL STEEL: A. Fabrication and erection of structural steel shall be in accordance with AISC "Specification for the Design, Fabrication and Erection of Structural Steel for Buildings" (latest edition). B. Structural steel team qualifications shall be: 1. Fabricator Qualifications: A qualified fabricator who participates in the AISC Certification Program and is designated an AISC Certified Plant, Category "Standard for Steel Building Structures" (STD) at time of bid. 2. Erector Qualifications: A qualified installer who participates in the AISC Certification Program and is designated an AISC Certified Erector, Category "Certified Steel Erector" (CSE) at time of bid. C. Structural steel shapes (used as beams and columns) shall conform to ASTM A992 Grade 50 KSI unless otherwise noted on the contract drawings. D. Plates, channels, rods, anchor bolts and angles shall conform to ASTM A36 unless otherwise noted of the contract drawings. E. Steel pipe shall conform to ASTM A53 Grade B or ASTM A501. F. Structural tubing shall conform to ASTM A500 Grade B (46 KSI minimum). G. All bolts (except anchor bolts) shall be high strength (HSB) shall conform to ASTM A325, 3/4" diameter unless noted otherwise. High strength bolts shall be used unless specifically noted on the drawings. H. All welding shall be performed by certified welders in accordance with AWS "Code for Arc and Gas Welding in Building Construction" (latest edition). The minimum electrode used shall be E70xx Low Hydrogen electrodes unless otherwise specified. I. Structural steel shall be primed painted with one coat of light gray primer meeting the minimum requirements of Federal Specification TT-P-664 or Steel Structures Painting Council Specification 15-68T, Type I. All members to receive spray on fire proofing shall not be painted. J. All beams shall be fabricated and erected natural camber up K. Connections may be single shear plate (or double angle) framed beam connections per AISC unless noted otherwise. All bolts shall be 3/4" diameter A-325-N unless noted otherwise. Shop connections may be bolted or welded, with welded connections equal to bolted connections. All bolts shall be tightened snug tight with suitable nuts and hardened washers unless noted otherwise. Design connections for the larger of either the shear value shown on the drawings or 75% of the maximum shear listed in the tables for "Allowable uniform load in Kips for beams laterally supported" at the bottom of each page in the "Properties And Reaction Values" Part 2 of the latest edition of the AISC "Manual Of Steel Construction". L. Splicing of structural steel where not detailed is not permitted with out prior written approval of the structural engineer. M. Structural openings, supports, anchors, etc. around or affected by mechanical, electrical and plumbing equipment shall be verified with the equipment purchased before proceeding with structural work affected. N. Provide for an allowance of 1 % of the total structural steel for the project to be fabricated and placed during progress of the work as may be directed by the Structural Engineer, in addition to the reinforcing steel indicated on the drawings. A credit for any unused quantity of this material at the end of the project shall be given to the Owner. XI. LIGHT GAUGE STEEL FRAMING: A. The light gauge steel framing members specified are based on structural properties of Dale/Incor. Members may be supplied by other manufacturers provided the members meet or exceed the structural properties as specified in Dale/Incor catalog. B. Standards: 1. American Iron and Steel Institute (A.I.S.I.) "Design of Cold Formed Steel Structural Members". 2. American Welding Society (A.W.S.) D1.3, Structural Welding Code - Sheet Steel". C. Track shall be securely anchored to the supporting structures as shown using the specified fasteners. Concrete anchors shall be installed after full compressive strength has been achieved. D. Studs shall be plumbed, aligned and securely attached to the flange or webs of both upper and lower tracks. E. Wall studs bridging shall be attached in a manner to prevent stud rotation. F. Temporary bracing shall be provided until erection is completed. Cn w w U �"s .�, o Z wo°p•Oo Z C/5 w ° W 1 U7 Z ��D Q z< > Cho Q�DMo �w_ QQ Z UQ C co? c�4 U w 00 < x r� CCJJ ti 2 cL U Ln ,r, o w w o N oCM > '..� CD CO a m Z Q L � m � CC N Z V O 1Z IL N Nm0 #o� lu°p w � a =� o> "Z I CERTIFY TO THE BEST OF MY KNOWLEDGE THAT THE DRAWINGS & SPECIFICATIONS COMPLY WITH THE APPLICABLE MINIMUM BUILDING CODES ISSUE DATE 12-05-08 1 2 3 4 REVISIONS A SWET NUMBER S-0.1 S 0 0 X D m S, M STRUCTURAL NOTES XII. CONCRETE MASONRY UNITS: A. Concrete block work under this section shall be as per plans and shall be plumb, true to line with level courses accurately placed. Where no pattern is indicated, masonry shall be laid in a running bond. B. The masonry work preformed under this section shall be constructed under the quality assurance program meeting or exceeding "Level 2 Quality Assurance" as defined in the latest edition of the ACI 530 Building Code Requirements for Masonry Structures. The visual inspection portions of Level 2 shall be preformed by the local building code authority and / or a qualified testing laboratory. The verification of fm shall be preformed by the material supplier's laboratory or qualified testing laboratory. The cost of this testing shall be paid by the contractor and reports shall be distributed to the Owner, Project Architect and Structural Engineer of Record. C. All concrete blocks shall have a minimum fm of 1500 PSI and be of standard weight conforming to ASTM C-90 Type N-1. Concrete masonry units shall be dry when laid. D. Mortar shall be used within 2 1/2 hours after initial mixing. Mortar that has stiffened due to evaporation within this period shall not be retempered or restored to workability. Mortar shall be Type S Type S (fm = 1800 PSI at 28 days) for above grade work, and Type M (fm = 2500 PSI at 28 days) for below grade (and retaining walls). E. Hollow units shall be laid with full mortar coverage of horizontal and vertical face shells. Webs shall also be bedded in all courses of piers, columns, and pilasters, and in the starting courses on footings, and where adjacent to cells or cavities to be filled with coarse grout. Mortar joints shall be 3/8" thick except where otherwise indicated. Exterior walls to be covered shall have flush joints, and interior wall joints shall be tooled with a round jointer. F. Horizontal joint reinforcing (wire type with 9 gage equal to Dur-o-wal) shall be placed at 16" o/c. vertically and shall extend at least 6" into vertical columns or pilasters. Horizontal reinforcement shall not be continuous across control joints and shall be placed fully embedded in face -shell mortar beds for their entire length (minimum mortar cover of 5/8"). G. Vertical reinforcement (where required) shall be placed in the center of masonry cores unless shown otherwise. This reinforcement shall be lapped (where required) a minimum of 48 bar diameters or 2'-1" whichever is greater. Masonry cores shall be filled with coarse grout conforming to ASTM C476. 1. 3000 PSI at 28 days 2. 3/8" aggregate 3. 8" - 11" slump H. Bond beams shall consist of load -bearing units filled with coarse grout and reinforced as indicated unless noted other wise in contract drawings. Reinforcement shall be continuous except through expansion (control) joints. Where bond beam is not broken at control joint, a dummy control joint shall be formed in the bond beam. I. Unfinished work shall be stepped back for tooling with new work. Toothing may be employed only when specifically approved. Before laying new work, loose mortar shall be removed and the exposed joint thoroughly cleaned. J. Use masonry saws to cut block as required. K. If wall reinforcing is not shown plans, place one #5 bar in a cell filled with coarse grout at a maximum spacing of 48". Also fill the first cell adjacent to any opening, and located three filled cells at any wall corner or intersection. L. Provide clean -outs for filling cells in lifts exceeding 4 ft, but lifts shall not exceed 12'-0. M. At the completion of the work all holes in joints of masonry surfaces to be exposed or painted (except weep holes) shall be filled with mortar and suitably tooled. Masonry walls shall be dry brushed at the end of each day's work and also after final pointing, and shall be left clean and free from mortar spots and droppings. Any cracks in masonry shall be repaired. Defective joints shall be cut out and repointed. XIII. DELEGATED (SPECIALTY) ENGINEERING REQUIREMENTS: A. GENERAL REQUIREMENTS: 1. Definition of Delega►ed (Specialty) Engineer: A Professional Engineer, who is licensed in the same state as the Project, not the Structural Engineer of Record, who specializes in and who undertakes the design of structural components prepared for this Project. 2. Submittals for custom designed, manufactured or fabricated load -carrying items and custom fabricated items that are required by codes or standards to resist forces and stresses, including their connections, anchorages, and attachments require a Delegated Engineer. 3. For each category of submittal requiring input from a Delegated Engineer, the Contractor shall attach to the first submittal a signed and sealed letter from the responsible Delegated Engineer stating "I certify that the design and drafting of the shop drawings which are signed and sealed by me were prepared under my direct supervision and control and to the best of my knowledge the shop drawings comply with the applicable minimum building codes and contract drawings." 4. Review by the Structural Engineer of Record of submittals is LIMITED TO the following: a) The specified structural submittals have been furnished. b) The structural submittals have been signed and sealed by the Delegated Engineer. c) The Delegated Engineer has understood the design intent and has used the specified structural criteria. No detailed check of calculations will be made. d) The configuration set forth in the structural submittals is consistent with the contract documents. No detailed check of dimensions or quantities will be made. 5. SUBMITTALS NOT MEETING THE ABOVE CRITERIA WILL NOT BE REVIEWED. B. Exterior curtainwalls shall be designed by the vendor's Delegated Engineer and shall include frame, glazing, and connections. Shop drawings shall be submitted for review and be signed and sealed by a structural engineer licensed in the same state as the Project. Design loads shall be based on wind speed and factors listed above under building design criteria. XIV. EPDXY ANCHORS: A. The epoxy anchors shown on this plan are based on the properties of HILTI HY 150 Injection Adhesive Anchors. The Contractor may use other manufacturers provided that their anchors meet or exceed the allowable tension and shear loads for the size and depth anchors specified in these design drawings. Additionally the product data for the substituted anchors shall be submitted to the Structural Engineer of Record for our approval. No work shall be performed using any alternate anchors with out first receiving the approval of our office. B. Anchoring adhesive shall be a two-part component 100% solids epoxy based system supplied through a static -mixing nozzle supplied by the manufacturer. This requirement shall be met regardless of which epoxy product or manufacturer that is used on this project. C. The threaded rods to be used in combination with the HILTI HY 150 Injection Epoxy system shall be fabricated from steel meeting or exceeding the properties of ASTM A36. WIND ZONES ON STRUCTURE POSITIVE WIND PRESSURES ON GLAZING & WALL COMPONENTS LOCATION ON BUILDING POS, PRESSURE POS, PRESSURE POS, PRE POS. PRESSURE < 10 SCE. FT. < 20 SO. FT. < 50 SO. FT. < 100 SO. FT. FIELD AREA 4 21B PSF 20Z PSF 1S.5 PSF 16B PSF GORNER AREA ❑5 21.8 PSF 20.8 PSF 15.5 PSF 18B PSF NEGATIVE WIND PRESSURES ON GLAZING & WALL COMPONENTS LOCATION OWN BUILDING NEC. PRESSLRE NEC. PRESSURE NEG. PRESSURE NEC. PRESSURE < 10 SCE. FT. < 20 SCE, FT. < 50 SCE. FT. < 100 SCE. FT. FIELD AREA 23.6 PSF 22.6 PSF 213 PSF 20.4 PSF CORNER AREA El 2S.1 PSF 2-12 PSF 24.6PSF 22b PSF ROOF WIND UPLIFT PRESSURES ZONE UPLIFT PRESSURE UPLIFT � UPLIFT PRESSURE UPLIFT PRESSLJ12E NET UPLIFT PRESSURE < 10 SO. FT. < 20 SCE. FT. < 50 SCE. FT. < 100 SO. FT. ON BAR JOIST 0 21S PSF 212 PSF 20.5P6F 15.5 PSF 1.9 PSF 36.5 PSF 32-6 PSF 215 PSF 25.1 PSF 16.1 PSF M 55.0 PSF 45.5 PSF 33.1 PSF 28.1 PSF 16.1 PSF WIND LOAD BASED ON USING THE ASCE 1-02 "MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES" METHODS OF CALCULATION FOR WIND PRESSURES AND THE FOLLOWING FACTORS: 1. WIND SPEED OF 110 MPH. 2. BUILDING IMPORTANCE FACTOR OF 1.0 (BUILDING CATEGORY II PER ASCE-1). 3. "ENCLOSED" BUILDING CLASSIFICATION (GCpi = 10.18). 4, BUILDING EXPOSURE CATEGORY 'B' 5. MEAN ROOF HEIGHT LESS THAN 30'-0". 6. ROOF ANGLE OF LESS THAN 10 DEGREES. x 6 ZZ f°0 '0011, Z ¢ 00 U) Z ¢wz Q > Q�D�cD Cwo n W ¢z��QLJ M U w�¢� x��Q oa U o a 'r > w o to po04 j w _J a Z m _J LL aC14J v� m Q N z F- LY O IE �so w Iis �o \ UO z !� QQ �> V O I CERTIFY TO TN1 EST OF MY KNOWLEDGE THAT THE DRAWINGS & SPECIFICATIONS COMPLY WITH THE APPLICABLE MINIMUM BUILDING CODES JOB NO H2O8 DRAWN/REVE:WED: B.MM. ISSUE DATE 12-06-08 REVISIONS A 1 2 3 4 SMET NUMBER S-0.2 S m� ll-1 rYS lIJ O Q U) N � 1(. a w (1) r- OIs (V o � x F- -6 a N a 41 z o� o w 0 o� x Z U w I 0 a_ a w O x 0 z Q 0 o LL Q � _i U) 6 � i 0 0 o v U L O O EL EL w S M L 0 so S Z o_ Q N � N z �w �Z �z w w O Q O " O� LL w ° -w w N 0 IL �IL w cF �C/) LL Z s� o� a 1 FOUNDATION PLAN 51.1 SCALE: 114" - 11-011 COLUMN SCHEDULE MARK TYPE 5 ASE PLATE NOTE C1 HS5 6x.xY4" 10"x10"x3/4" THICK BASE PLATE. W/ (4) 3/4" DIA. EPDXY ANCHOR RODS REFER TO DETAIL, 2/5-2.1 4 3/5-2.1 FOOTING 50HEDULE MARK Fx 51 ZE RE I NFORGEMENT R�M�R�GS LENGTH WIDTH DEPTH TOP BOTTOM FI 4'-0" 4'-0" " 1'-0 - (5) #5 BAR EACH WAY - F2 CONT 2'-0" 1'-0" - (2) #5 BAR CONT - NOTES: 1. THE BOTTOM OF ALL FOOTINGS SHALL BE (1'-4") MIN. BELOW FINISHED EARTH GRADE. 2. THE TOP OF ALL INTERIOR FOOTINGS SHALL BE (8") BELOW FINISHED FLOOR U.N.O. (UNLESS NOTED OTHERWISE). 3. THE TOP OF ALL EXTERIOR FOOTINGS SHALL BE (1'-4") BELOW FINISHED FLOOR U.N.O. SEE DETAI FOR BLOC, BRIDGING TYPICAL HEADER SCHEDULE MARK ROUGH OPENING SIZE KING 5TUD5 TRIMMER STUDS REQUIRED 012 TEK 5CREW5 WIDTH (UN.O.) (UN.O.) (HDR. TO KING STD. CONN.) Hl 8'-0" OR LESS (2) C8" x IS GA. 1 2 6 EACH SIDE TS ST BE SE_ _. _ _-• •-_-- FOR * OF TEK SCREWS EQUALLY SPACED SECTION A -A FADER STUDS KING STUDS r=1 TEK SCREWS USE METAL TRACK m- TOP OF ALL TRIMMER STUDS TRIMMER STUDS HEADER DETAILS SCALE, N.T.S. SEE HEADER SCHEDULE FOR N OF TEK SCREWS EQUALLY SPACED a r-2-' FRAMING PLAN �11 SCALE: 114" - 1'-011 3/16" 3/4" AT 1/3 PT5, OF FULL 3/16" 3/4" HGT. WALL KING STUDS 2 I 5-I.I 5-I.I I I I I I I t � KEY PLAN tx WzUr° 6 Z O z w � M Z C/) Qwz z¢ > wo v� Q ►-� �D w a c.� o ¢ pCa�+@w x U °°<� U�oa o a w W O N O04 Q co) Q Fm m Z J ;� LL N J m Q W�W Q Z H U O J + C= Qmw lusnl lfl o �? m� o C'V 00 O QdQ LL C3 LL z 1 CERTIFY TO THE BE*-r OF MY KNOWLEDGE THAT THE DRAWINGS & SPECIFICATIONS COMPLY WITH THE APPLICABLE MINIMUM BUILDING CODES JIM NO: HM DRAW"EVE:WED: B.MM ISSUE DATE 12-05-08 REVISIONS Q 1 2 3 4 SWET NUM3M S-1.1 713 O rY� W s m � o du) N Lo w wa z o� N o m (A ?: x a 0 )_ O ? fL o w m 13Z w (V w 1 O d cr O= 0 (v O z � a K o w Q O i w O � L 0 � O V w j L p +' O N w w sm L ~O S Z S N z �of �W �Z �z �Z w �2 00 N a � a O OLL LL N 0 w .. w n 0 � a O w � x �u) i� Z S r) a� Q Ln H CONTRACTION JOINT Ys" WIDE SAW CUT TO BE MADE NO LATER THAN 24 HOURS AFTER PLACEMENT OF CONCRETE SLAB. CUT SHALL BE MIN, SLAB THICKNESS/4 IN DEPTH (I.E. I" FOR A 4" THICK SLAB) TOP OF SLAB ° d d ° .. ° ...d a SMOOTH DOWEL SCHEDULE SLAB DEPTH (IN.) DIAMETER (IN.) TOTAL LENGTH (IN-) SPACING C TO C (IN.) 4 Jai 18 12 5 % 18 12 6 3/4 18 12 1 yo 24 12 8 1 24 12 g 1YS 24 12 10 1Y4 24 12 CONSTRUCTION JOINT DOWELS SHALL BE SAW CUT NOT SHEAR (IF APPLICABLE) CUT TO PREVENT END DEFORMATION. CENTER ROD OVER JOINT. SEE SCHEDULE ABOVE FOR SIZE 4 SPACING e a 4,1 da d d- 4 CONTRACTION CONSTRUCTION JOINTS SCALE 1 1/7 - I'-O' EPDXY ANCHOR ROD SCHEDULE COLUMN MARK ANCHOR ROD LENGTH (L) REMARKS Gl (4) 3/4" DIA. g" ,gKTOP OF FOOTING ASTM A36 STEEL 3000 PSI CONIC. (MIN.) ANCHOR BOLT SCHEDULE SCALE: N.T.S. 8"x18 GA (8005162-43) STUD 6 24" O.G. 8"x18 GA TRACK (800TTD-54) w/ (2) 012 TEK SCREWS TO EACH STUD 4 (1) Y4" DIA TAPCON TO MASONRY -0 12" EXPANSION JOINT O.C. STAGGERED w/ MINIMUM MATERIAL 1Y4" EMBED NEW SLAB SAME THICKNESS EXISTING SLAB NEW SLAB � AS EXISTING. OTHERWISE PER PLAN w GONG. SLAB AS INDICATED U ON FND. PLAN. 6 - MIN. \ / d d X a -��i ill III I II_ 16" LONG 03 SMOOTH DOWELS EPDXY GROUTED a 2411 O.C. - DOWELS TO BE SAW CUT TO PREVENT END DEFORMATION. NEW TO EXISTING SLAB CONNECTION SCALE 1 1/7 - 1'-O' —III � III —III —III —I I _ � I =III 1III=IIIIIII I � (2) COURSE OF I=1 1= 8" CONCRETE —III d � III —I 1(— MASONRY BLOCK— =111 I 1 —1 (2) *5 BARS, 2' —0" CONTINUOUS PERIMETER STRIP FOOTING SCALE: 3/4'- 1'-0' 12" TYP. 0 0 \, o 1 0 0 / THICKENED EDGE BEYOND CONC. SLAB PER PLAN FOR COLUMN AND BASE M SIZE SEE FND. PLAN 1 1/2" LEVELINGc GROUT TYP. is COL. BASE IIII�II !SEE FOUNDATION PLAN FOR SIZE AND REINFORCING COLUMN FOOTING EXPANSION JOINT MATERIAL NEW SLAB PER PLAN d � x x :illl= (2) COURSE OF _ 8" CONCRETE MASONRY BLOCK I SCALE, 3/4' - I'-O' 8"x18 GA (6005162-43) STUD Q 24" O.C. 1/2" THICK — EXPANSION JOINT MATERIAL NEW CONC. SLAB PER PLAN 8„ EXISTING FOOTING NEW SLAB AT EXISTING BUILDING SCALE: 3/4' - I' -Ow 1 8"x18 GA TRACK (800TTD-54) 5-3.1 w/ (2) 012 TEK SCREWS TO (� EACH STUD 4 (1) Y4" DIA TAPCON TO MASONRY s 12" O.G. STAGGERED w/ MINIMUM V4" EMBED EXPANSION JOINT MATERIAL NEW SLAB NEW SLAB PER PLAN PER PLAN w J U d a X. - =1 (1) 05 BAR CONTINUOUS � I I— I I IIII—III--� a s— d III —III— I _ �—III—I—III III— I 11- 1 (u 45 BAR I I=1 I I=11 11 I I III=1 ,III, ;, I ,III=1 I �' _► I I , I I I=1 I I IF-(1) «5 BARS, 8 CONTINUOUS 05 BARS, CONTINUOUS PERIMETER STRIP FOOTING SCALE, 3/4' - I'-0' PERIMETER SLAB FOOTING SCALE, 3/4' - 1'-O' W (� z � OU0 Z Z 0 0o W 0. W x xzo C/)Zdw- F" C7 L1 > o ^� W o 52 , U zu4: O � §w T, ►T+ c� CD () -) ua o w W cr o to Q > T to M w c"' a z m J Q ILL Q a J L co N Z U O E ") 40 N-. m~ * Q 00 H O tu 3 d Q C-) v <�j G /ILO I CERTIFY TO THE BEST OF M KNOWLEDGE THAT THE DRAWINGS & SPECIFICATIONS COMPLY WITH THE APPLICABLE MINIMUM BUILDING CODES JOB NO H2O8 DRAWN/REVIEWED: BMM ISSUE DATE 12-05-08 REVISIONS Q 2 3 4 SWET NUMBER S-2.1 METAL STUD PER PLAN v� 1k4- VERIFY (5) 3/4" VIA �h BOLT CONNECTION 6XI8xi6 GA CONTINUOUS IN FIELD TRACK (6005162-45) w/' (I) Y4" VIA TAPGON Y4/ `%' EXI5TING W24x55 MINIMUM IY4" EMBED ` � � "' EXISTING WI2x26 w/ OLTOP OF STEEL 2"x2"xl2 6A x0'-(b" LONG 012 TEK SCREWS ®12" O.G. CONCRETE INFILL EL: IS'- '2 F-- , MIN (3) 0.145" DIA PDF ANGLE w/ (4) #12 TEK (TYPICAL) BETWEEN FLANGES { FASTENERS (OR #12 TEK 50REWS TO EACH STUD, PLYWOOD TO REMAIN 0 SCREWS) TO ANGLE TOP BOTTOM ll'4"xly4"xl6 GAUGE SHEATHING O 1 3/I6" ABOVE d BELOW ANGLE (MINIMUM) PER PLAN � EXISTING ANGLE ABOVE -- L 5"x5"xI6 6A CONTINUOUS 4 BELOW - TOP OF STUD EXISTING WI2x26 # - a ,� ANGLE w/ (1) 12 TEK (MIN 3 VERTICAL LEGS) COLD ROLLED LOCATE BRIC)GING AT x ,,r 1 • EL: 15 -O X x 50REW TO EACH STUD X "U" CHANNEL • • 4'-0" O.C. MAX. x x �, - -- 8"x8"xY2" GAP PLATE w/ 3/e" GU55ET PLATE PLYWOOD SHEATHING f BOTH 51VE5 PER PLAN STUD FRAMING ; - f PER PLAN NEW COLUMN C: PER PLAN EXISTING WI2x26 � EXISTING MASONRY X X i TO REMAIN 2"x2"xl2 GA xO'-6" LONG " WALL TO REMAIN NEW COLUMN ANGLE w/ (4) #12 TEK - 4 PER PLAN X X GEE 3�/8"x 18 GA STUD 3 X (5625162-45) w/ (4) #12 TEK 5GREW5 TO EACH STUD 8 /e GUSSET (U Y4" VIA TAPGON w/ PLATE X SCREWS TO EACH STUD MINIMUM V4" EMBED TO STUD FRAMING X GU55ET PLATE LAYOUT PER PLAN MASONRY (4) #12 TEK 5CREW5 FOR STUD TO ANGLE CONNECTION LIGHT GAUGE STUD LATERAL SL PPORT STUD TO MASONRY CONNECTION 3 FEW COLUMN TO EXISTING BEAM CONFECTION 4 NEW ROOF TO EXISTING BEAM S-3a SCALE N.T.S. s-al SCALE I' - 1'-V 3-3.1 SCALE I' - 1'-0' 5-3.1 SCALE 1 1/7 - 11-00 5"xI5 GA TRACK 8"xlb GA TRACK (BOOTTD-43) w/ (2) (500TTD-45) w/ (2) CEILING JOISTS SPACED #12 TEK 5CREW5 TO #12 TEK SCREWS TO PER PLAN EACH STUD EACH STUD L 5"x5"xl6 GA CONTINUOUS ANGLE w/ (1) #12 TEK GEE 5"x18 GA (5005162-45) PLYWOOD SCREW TO EACH STUD BLOCKING ®4'-O" O.G. w/ SHEATHING PER PLAN (4) #12 TEK 5CREWS PLYWOOD 5HEATHING (4) #10 TEK SCREWS TO PLYWOOD 5HEATHING �' FOR 5TUD TO 5710 PER PLAN STUD FROM SHEATHING 4 PER PLAN CONNECTION TYPICAL ROOF STUD LIGHT GAUGE STUD PER PLAN �\ GKIN6 i T.O. STUD -.,..... �..... , ^ — - r T.O. STUD -- wY�v r. Z� ... _...:: TO I REMAIDE EL: 14'-q" - - — --- - - --� — EL: VARIES L -- }' x Cl � 11/2 "xrY32"xl& GAUGE RUNNER CHANNEL AT BOTTOM 5 "x 18 6A 57 BU I LDOUT 24" O.G. (5005162-4! (4) #12 TEK 5CREW5 FOl STUD TO 5Tl GONNEGTIO1 (TYPICAL) MAIN b"x18 c (b005162-4; VERTICAL 5 a 24" O.G. :EWS TEK SCREWS. JOIST BLOCKING, BRIDGING DETAIL_ SCALE N.T.S. Y2" PLYWOOD SHEATHING YV/ #10 WOOD TO METAL 50REW5 ® 6" O.G. (TYPICAL) 6 "x 18 GA STUD BU I LDOUT ® 24" O.G. (6005162-45) 2 "x2 "x 12 6A xO'-(o" LONG ANGLE w/ (4) #12 TEK SCREWS TO EACH STUD W/ (4) #10 WOOD TO METAL TO PLYWOOD. LOGAT' CLIPS ® 4'-0" O.G. 5-5.1 Y2" PLYWOOD SHEATHING w/ #10 WOOD TO METAL 5GREW5 ® 6" O.G. STUD FRAMING (2) #12 TEK SCREWS f XX PER PLAN FOR STUD TO STUD CONNECTION TYPICAL I YI RUNNER CHANNEL s-31 STUD FRAMING PER DETAIL 5/5-5.1 PER PLAN _ 8 xl8 6A (8005162-45) VERTICAL STUDS ® 24" O.G. 8"xI5 SA (5005162-43) .� VERTICAL STUDS o 24" O.G. (4) #12 TEK SCREWS FOR STUD TO 5TUD CONNECTION STUD PARAPET CONDITION SCALE I* - I' -a Y2" PLYWOOD SHEATHING w/ #10 WOOD TO METAL SCREWS ® 6" O.G. STUD PARAPET CONDITION SCALE I" - 1'-0' GEE 6"x18 GA xl'-6" TALL, MIN VERTICAL STUD (6005162-45) W/ (8) 0.145 D I A PDF TO BEAM WEB COPE 4 BEND STUD AS REOUIRED TO ALLOW MIN 2" LAP AT TOP OF STUD FOR CONNECTION TO BEAM FLANGE. FASTEN TO BEAM W/ (2) 0.145" MIA PDF EXISTING STEEL BEAM TO REMAIN LIGHT GAUGE STUD TO BEAM CONNECTION SCALE 1 1/7 - 1'-0* G -- Oz Ur ., Li o°O, N K cri z , � oo Q C!) z w Z Q z¢ > o Q �Q o 2 x�o� U (� ;n r- o w W cr o to N O < > to M W 0 C7 a FEWm Z J cr JOJ LL N_ J 0 to m } c N Z U ly 0 R 1 ' .o ((1 Li m� � O �L � Q � Q � Q !x \ _ IL O I CERTIFY TO THE BEST OF MY KNOWLEDGE THAT THE DRAWINGS & SPECIFICATIONS COMPLY WITH THE APPLICABLE MINIMUM BUILDING CODES JOB B NO H2O8 DRAWN/REVEWED: BMM ISSUE DATE 12-05-08 REVISIONS Q 1 2 3 4 FACADE FRAMING SCALE 1 1/7 - I'-0• SHEET NUMBER S-3.1 ■ t V 4D I vo