HomeMy WebLinkAbout6638, 6634, 6646 Dairy RdGENERAL NOTES: THIS BUILDING HAS BEEN DESIGNED TO CONFORM TO THE 2020 FLORIDA BUILDING CODE 7 TH EDITION ARKAY ENGINEERING, INC.; A REGISTERED, LICENSED, FLORIDA PROFESSIONAL STRUCTURAL ENGINEERING COMPANY, HAS APPLIED 'RATIONAL ANALYSIS" FOR THE STRUCTURAL DESIGN OF THIS STRUCTURE. THE BUILDING (INCLUDING ALL COMPONENTS AND CLADDINGS) SHALL BE DESIGNED FOR THE FOLLOWING SUPERIMPOSED LOADS: FLOOR: LIVE LOAD - 50 P.S.F. DEAD LOAD - 10 P.S.F. ROOF - LIVE LOAD (TRUSS TOP CHORD) - 20 P.S.F. DEAD LOAD (TRUSS TOP CHORD) - 10 P.S.F. DEAD LOAD (TRUSS BOTTOM CHORD) - 10 P.S.F. ASSUMED TRUSS SELF WEIGHT (DEAD LOAD) - 7 P.S.F. WIND' BUILDING IS DESIGNED TO CONFORM TO ASCE 7-16, CHAPTERS 26 THRU 31; PER 2020 FLORIDA BUILDING CODE, 7 TH EDITION - SECTION R301.2.1.1. AND 2020 FLORIDA BUILDING CODE 7 TH EDITION SECTION 1609 WIND DESIGN ASSUMPTIONS: BUILDING EXPOSURE - B BUILDING RISK CATEGORY - II MEAN ROOF HEIGHT 30' OR LESS HEIGHT & EXPOSURE ADJUSTMENT COEFFICIENT = 1.0 ENCLOSED BUILDING INTERNAL PRESSURE COEFFICIENT = +/- 0.18 WIND SPEED SHOWN AT THE BOTTOM RIGHT CORNER OF THIS SHEET ALL STRUCTURAL ELEMENTS, EXTERIOR WALLS AND INTERIOR WALLS SHALL BE TYPE V CONSTRUCTION PER FBC 602.5 SOIL BEARING & COMPACTION: COMPONENT & CLADDING WIND LOADS ALL OTHER BUILDING ROOF OVERHANG COMPONENT 20NE LOADS LOADS 1 N/A +32.3/-35.3 2 -65.7 +32.31-56 2 3 -110.6 +32.3/-89.0 4 N/A t 35.3/-38.2 11 N/A +35.3/A7.2 THESE PLANS WERE DRAWN BASED UPON AN ALLOWABLE SOIL BEARING CAPACITY OF 2,000 P S F. (MINIMUM). THE CONTRACTOR/PROPERTY OWNER ARE RESPONSIBLE FOR VERIFYING THAT THE SOIL ON THE SITE IS PROPERLY PREPARED & COMPACTED SUCH THAT IT CAN SUPPORT A 2,000 P.S.F. FOUNDATION LOADING. ARKAY ENGINEERING, INC.; A REGISTERED, LICENSED, FLORIDA PROFESSIONAL STRUCTURAL ENGINEERING COMPANY; DESIGNED THESE FOUNDATIONS WITHOUT VISITING THE CONSTRUCTION SITE NOR PERFORMING ANY SOIL TESTING. ARKAY ENGINEERING, INC. SHALL NOT BE RESPONISIBLE FOR THE SITE SOILS ABILITY TO SUPPORT THE BUILDING LOADS. FOUNDATIONS & SLAB -ON -GRADE: BUILDING SITE SHALL BE SCRAPED TO REMOVE ALL ORGANIC MATERIALS WITHIN THE BUILDING AREA. ANY ADDITIONAL FILL PLACED ON THE BUILDING PAD AREA, SHALL BE COMPACTED SUCH THAT IT CAN ADEQUATELY SUPPORT A 2,000 P.S.F. FOUNDATION LOADING. SLAB SHALL BE PLACED OVER A 6 MIL VAPOR BARRIER ON CLEAN, ADEQUATELY COMPACTED AND TERMITE POISONED SOIL. CONCRETE UTILIZED IN THE FOUNDATIONS AND SLABS SHALL HAVE A MINIMUM 28 DAY COMPRESSIVE STRENGTH OF 2,500 P.S.I. REINFORCING STEEL SHALL BE GRADE 40 MINIMUM AND IDENTIFIED IN ACCORDANCE WITH ASTM A-615. LAP SPLICES, WHERE REQUIRED, SHALL BE A MINIMUM OF 25' FOR #5 REBAR, 30" FOR #6 REBAR & 35" FOR #7 REBAR. PLANS ARE ENGINEERED FOR A MAXIMUM STEMWALL HEIGHT OF 4 COURSES (AFTER FINAL SITE GRADING) THE CONTRACTOR OR BUILDING OWNER SHALL DETERMINE THE EXACT STEMWALL HEIGHT BASED UPON SITE CONDITIONS PRIOR TO POURING THE FOUNDATION AND CONTACT ARKAY ENGINEERING WHEN MORE THAN 4 COURSES ARE REQUIRED. A FOUNDATION SURVEY SHALL BE PERFORMED AND A COPY OF THE SURVEY SHALL BE ON THE SITE FOR THE BUILDING INSPECTORS USE, OR ALL PROPERTY MARKERS SHALL BE EXPOSED AND A STRING STRETCHED FROM MARKER TO MARKER TO VERIFY THE REQUIRED BUILDING SETBACKS. MASONRY WALLS: CONCRETE MASONRY UNITS SHALL BE HOLLOW UNIT MASONRY IN ACCORDANCE WITH ASTM C-90 AND SHALL HAVE A MINIMUM F'M OF 1,500 P.S.I. MORTAR SHALL CONFORM TO ASTM C-270 AND SHALL BE EITHER TYPE M OR S. REINFORCING STEEL SHALL BE GRADE 40 MINIMUM AND IDENTIFIED IN ACCORDANCE WITH ASTM A-615. LAP SPLICES, WHERE REQUIRED, SHALL BE A MINIMUM OF 25" FOR #5 REBAR, 30" FOR #6 REBAR & 35" FOR #7 REBAR. GROUT FOR THE POURED CELLS AND LINTELS SHALL HAVE A MAXIMUM COURSE AGGREGATE SIZE OF 3/8', PLACED AT AN 8 TO 11 INCH SLUMP AND HAVE A MINIMUM 28 DAY COMPRESSIVE STRENGTH OF 2,500 P.S.I. (WHEN TESTED PER ASTM C-1019), PROVIDE CLEAN -OUT OPENINGS (12 SO IN_) IN CELLS CONTAINING SPLICED REINFORCEMENT, WHEN THE GROUT POUR EXCEEDS 5 FEET IN HEIGHT. TIMBER MATERIALS ALL TIMBER MATERIALS SHALL BE AS FOLLOWS: ALL LUMBER IN CONTACT WITH MASONRY WILL BE PRESSURE TREATED MATERIALS INTERIOR STUD WALLS TO BE OF 2 X 4 #2 SPRUCE OR BETTER WITH SINGLE 2 X 4 P.T. PINE BOTTOM PLATE AND SINGLE 2 X 4 #2 SPRUCE TOP PLATE WITH STUDS SPACED MAXIMUM 24" OC. WALLS TO HAVE 112" GYPSUM BOARD EACH SIDE, WITH WALLS AT GARAGE TO HAVE MINIMUM R-11 INSULATION SOIL TERMITE TREATMENT: TERMITE PROTECTION SHALL BE PROVIDED BY REGISTERED TERMITICIDES, INCLUDING PESTICIDES APPLIED TO SOIL, OR WOOD, BAITING SYSTEMS, OR OTHER APPROVED PROTECTION LABELED FOR USE AS A PREVENTATIVE TREATMENT TO NEW CONSTRUCTION. A "CERTIFICATE OF COMPLIANCE" SHALL BE ISSUED TO THE BUILDING DEPARTMENT BY A LICENSED PEST CONTROL COMPANY BEFORE A "CERTIFICATE OF OCCUPANCY" WILL BE ISSUED. THE CERTIFICATE SHALL STATE "THE BUILDING HAS RECEIVED A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN TERMITES. THE TREATMENT IS IN ACCORDANCE WITH THE RULES AND LAWS OF THE FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES-" IF A REGISTERED TERMITICIDE BAIT SYSTEM IS TO BE USED FOR SUBTERRANEAN TERMITE PREVENTION, DO NOT APPLY. A SIGNED FIVE YEAR CONTRACT FROM THE ISSUE OF THE CERTIFICATE OF OCCUPANCY ASSURING INSTALLATION, MAINTENANCE AND MONITORING OF THE BAITING SYSTEM SHALL BE PROVIDED TO THE BUILDING OFFICIAL PRIOR TO THE SLAB POUR_ THE SYSTEM MUST BE INSTALLED PRIOR TO FINAL BUILDING APPROVAL. INITIAL SOIL POISONING TREATMENT SHALL BE DONE AFTER ALL EXCAVATION, BACKFILLING & COMPACTION ARE COMPLETE ANY SOIL DISTURBED AFTER THE INITIAL TREATMENT SHALL BE RE -TREATED (INCLUDING ANY BOXED OR FORMED AREAS) - BOXED AREAS IN THE CONCRETE SLAB FOR INSTALLATION OF TRAPS SHALL BE MADE WITH PERMANENT METAL OR PLASTIC FORMS. PERMANENT FORMS MUST BE OF AN ADEQUATE SIZE & DEPTH TO ELIMINATE ANY DISTURBANCE OF THE SOIL AFTER THE INITIAI TREATMFNI. A MINIMUM 6 MIL VAPOR BARRIER MUST BE INSTALLED TO PROTECT AGAINST RAINFALL DILUTION. IF RAINFALL OCCURS BEFORE VAPOR BARRIER PLACEMENT, RE -TREATMENT SHALL BE REQUIRED ANY CONCRETE OVERPOUR, MORTAR OR STUCCO MATERIALS ALONG THE FOUNDATION PERIMETER MUST BE REMOVED PRIOR TO EXTERIOR SOIL TREATMENT EXTERIOR SOIL TREATMENT MUST BE APPLIED UNDER ALL EXTERIOR CONCRETE OR GRADE WITHIN 12 INCHES OF THE STRUCTURE SIDE WALLS AN EXTERIOR VERTICAL CHEMICAL BARRIER SHALL BE INSTALLED AFTER CONSTRUCTION IS COMPLETE (INCLUDING LANDSCAPING AND IRRIGATION). ANY SOILS DISTURBED AFTER THE VERTICAL BARRIER IS APPLIED, SHALL BE RE -TREATED. CONDENSATE AND ROOF DOWNSPOUTS SHALL DISCHARGE AT LEAST 12 INCHES AWAY FROM THE BUILDING SIDEWALLS (PER FBC R318). AFTER ALL WORK IS COMPLETED, ANY LOOSE WOOD AND FILL MUST BE REMOVED FROM BELOW AND WITHIN 12 INCHES OF THE BUILDING. THIS SHALL INCLUDE ALL GRADE STAKES, TUB TRAP BOXES FORMS, SHORING AND ANY OTHER CELLULOSE CONTAINING MATERIALS. THE DISTANCE FROM THE EXTERIOR WALL COVERING (EXCEPTIONS: PAINT AND DECORATIVE CEMENTITIOUS FINISHES LESS THAN 5/8 INCH THICK ADHERED DIRECTLY ONTO THE FOUNDATION WALL) AND FINAL EARTH GRADE SHALL NOT BE LESS THAN 6 INCHES TO ALLOW FOR INSPECTION FOR FUTURE TERMITE INFESTATIONS TRUSSES IF THE CONTRACTOR, TRUSS MANUFACTURER OR ANY OTHER DESIGN PROFESSIONALS REVISE THE TRUSS SYSTEM LAYOUT FROM THOSE SHOWN ON THESE PLANS T_ L HANSON & ASSOCIATES IS REQUIRED TO REVIEW ALL FINAL CONSTRUCTION DOCUMENTS FOR COMPLIANCE WITH THE DESIGN INTENT PRIOR TO COMMENCEMENT OF THE PROJECT. EXTERIOR WINDOWS & DOOR ASSEMBLIES: ALL EXTERIOR WINDOW & GLASS DOORS SHALL BE TESTED IN ACCORDANCE WITH ANSI/AMMA/NWWDA 101/IS2 STANDARDS AND BEAR AN AMMA OR WDMA LABEL IDENTIFYING THE MANUFACTURER, PERFORMANCE CHARACTERISTICS AND APPROVED PRODUC I I ES I ING EN 11 I Y. ALI. MULLIONS AND ADJACENT DOORIWINDOW ASSEMBLIES SHALL BE TESTED OR ENGINEERED TO TRANSFER 1.5 TIMES THE DESIGN LOADS TO THE ROUGH OPENING SUBSTRATE. INSTALL ALL WINDOW & DOOR ASSEMBLIES PER THE MANUFACTURERS ANCHORING RECOMMENDATIONS TO ACHIEVE THE DESIGN PRESSURES SPECIFIED. ELECTRICAL, PLUMBING & MECHANICAL IN ACCORDANCE WITH CHAPTER 471.003(2)(1) OF THE FLORIDA ADMINISTRATIVE CODE, ELECTRICAL, PLUMBING AND MECHANICAL SYSTEMS SHALL BE DESIGNED BY THE RESPECTIVE CONTRACTORS TO MEET ALL APPLICABLE CODES. THE ELECTRICAL, PLUMBING AND MECHANICAL SYSTEMS DRAWN HEREON ARE BASED UPON A DESIGN PROVIDED BY THE OWNER TO ADDRESS HIS/HER REQUIREMENTS. ALL ELECTRICAL OUTLETS IN BATHROOMS, KITCHEN, GARAGE AND AT EXTERIOR LOCATIONS SHALL BE WIRED INTO A GROUND -FAULT INTERRUPTER "GFI" CIRCUIT. ALL ELECTRICAL OUTLETS IN HABITABLE SPACES SHALL BE WIRED INTO AN ARC -FAULT INTERRUPTER SAFETY GLAZING: THE FOLLOWING SHALL BE CONSIDERED SPECIFIC HAZARDOUS LOCATIONS FOR THE PURPOSES OF GLAZING PER THE FLORIDA BUILDING CODE, RESIDENTIAL - SECTION R308: (1) GLAZING IN SWINGING DOORS, FIXED AND SLIDING PANELS OF SLIDING DOOR ASSEMBLIES. (2) GLAZING IN DOORS AND ENCLOSURES FOR HOT TUBS, WHIRLPOOLS, SAUNAS, STEAM ROOMS, BATHTUBS, AND SHOWERS. GLAZING IN ANY PORTION OF A BUILDING WALL ENCLOSING THESE COMPARTMENTS WHERE THE BOTTOM EDGE OF THE GLAZING IS LESS THAN 60 INCHES ABOVE THE DRAIN INLET. (3) GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL ADJACENT A DOOR WHERE THE NEAREST VERTICAL EDGE IS WITHIN A 24 INCH RADIUS OF THE DOOR IN A CLOSED POSITION AND WHOSE BOTTOM EDGE IS LESS THAN 60 INCHES ABOVE THE FINISHED FLOOR OR WALKING SURFACE. (4) GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL, OTHER THAN THOSE LOCATIONS DESCRIBED IN ITEMS (2) AND (3) ABOVE THAT MEETS ALL OF THE FOLLOWING CONDITIONS: A) EXPOSED AREA OF AN INDIVIDUAL PANE GREATER THAN 9 SQ. FT. B) BOTTOM EDGE LESS THAN 18 INCHES ABOVE THE FLOOR. C) TOP EDGE GREATER THAN 36 INCHES ABOVE THE FLOOR. D) ONE OR MORE WALKING SURFACES WITHIN 36 INCHES HORIZONTALLY OF THE PLANE OF THE GLAZING. REFER TO THE FLORIDA BUILDING CODE, RESIDENTIAL - SECTION R308 FOR ADDITIONAL AREAS THAT MAY BE CONSIDERED A HAZARDOUS LOCATION FOR THE PURPOSE OF GLAZING. BUILDING DESIGNS 13821 U.S. HWY 98 BY PASS DADE CITY, FLORIDA 33523 OFFICE 352-523-2077 SHELL OFFICE BUILDING 6638 DAIRY ROAD ZEPHYRHILLS, FLORIDA JOB SITE LOCATION MAP FLORIDA FIRE PREVENTION CODE 7TH EDITION 7 TH EDITION 2020 FLORIDA BUILDING CODE 7 TH EDITION 2020 FLORIDA ACCESSIBILITY CODE BUILDING HAS WOOD ROOF SYSTEM LIGHT FRAME CONSTRUCTION SIGN REQUIRED BUILDING DATA TOTAL AREA 3242.2 SO. FT. USE AND OCCUPANCY: BUSINESS GROUP B CONSTRUCTION TYPE : VB FIRE PROTECTION : NON SPRINKLED RYMAN CONSTRUCTION INC 36413 STR RD 54 ZEPHYRHILLS, FL 33541 OFFICE 813-782-0825 6001u_1 REVIEW DATE:_�_�_2, / CITY OF ZEPHYRHILLS BUILDING OFFICIAL PLAN INDEX SITE PLAN BY OTHERS SHEET B 1: BUILDING FLOOR PLAN WINDOW AND DOOR SCHEDULE FLORIDA PRODUCT APPROVAL SHEET B 2: BUILDING ELEVATIONS SHEET B 3: BUILDING FOUNDATION PLAN DECK FOUNDATION PLAN LINTEL DETAIL LINTEL CHART DOOR BUCK DETAIL WINDOW BUCK DETAIL SHEET B 4: WALL SECTION DETAILS A & B DECK FRAMING PLAN DECK CUT SECTION DETAIL SOFFIT DETAIL WINDOW FLASHING DETAIL PLYWOOD DETAIL SHEET B 5: ROOF TRUSS PLAN TRUSS BRACE DETAIL VALLEY FRAMING DETAIL FLASHING DETAIL SHEET E 1 : ELECTRICAL PLAN RISER DETAIL ELECTRICAL LEGEND ALL WORK SHALL COMPLY WITH PREVAILING CODES FLORIDA BUILDING CODE, NATIONAL ELECTRIC CODE, AND THE CITY OF ZEPHYRHILLS ORDINANCES AFKAY EN(SINEERING INC,. structural engineers 1955 E. Edgewood Drive, Lakeland FI 33803 Phone 863-688-6500 Fax 863-688-655-1 State of Florida Certificate of Authorization " E86341 Richard L Kiddey P.E_ - Florida License M 31296 ARKAY JOB # 19870 9 I 47 UNIT #1 OFFICE AREA 1575.8 ENTRY 45.3 TOTAL 1621.1 APPROVED PRODUCT LIST N zcv)U z m O~ o o tn >0LL Q G5 Z U r� W ~O 101 8w Z W 0 o N N lt7 'ALL WILL SUPPORT THE BUILDING A Z p (A C11 a M .TAINING WALL OF RETENTION POND >- W :) my m ao u. 94.26' BOTTOM OF RETENTION POND 4' 4" LL 0)0 UJ c (V M 0 FLOOR PLAN 1 /4" = 1' O" ALL EXTERIOR WALLS ACT AS SHEAR WALLS STATE OF FL. PRODUCT CATEGORY SUB CATEGORY MANUFACTURER APPROVAL# STRUCTURAL COMPONENT HU26-2, U26 SIMPSON FL 10531 STRUCTURAL COMPONENT HETA20 SIMPSON FL 11473 STRUCTURAL COMPONENT LINTEL HEADER CAST CRETE CORP FL 158.1 ROOFING ASPHALT GAF SHINGLES ALL FL 10124.1 ROOFING UNDERLAYMENT GAF FL 10626.1 SINGLE HUNG WINDOWS NON IMPACT PLYGEM 1500 OR EQ FL 16103.1 SOFFIT & FASCIA TRIM SOFFIT AMERICAN CONSTRUCTION METALS FL 12019.1 ATTIC VENTS VENTS FLORIDA METAL PRODUCTS FL 21580.1 EXTERIOR DOOR STEEL SWINGING PREMIER PRODUCTS OR EQ FL 17460.4 EXTERIOR DOOR GLASS SWINGING YKAP AMERICA OR EQ FL 12892.7 UNIT #2 OFFICE AREA 1575.8 ENTRY 45.3 TOTAL 1621.1 DOOR AND WINDOW SCHEDULE PLAN OPENING TYPE A WINDOW 25 SINGLE HUNG VINYL INSULATED GLASS BRONZE OR WHITE FRAME T.B.V. 6'0"X8'0" INSULATED STORE FRONT GLASS DOOR PULL HANDLE EACH DOOR EXTERIOR, SOLID BAR INTERIOR EACH DOOR B DOOR CYL KEY LOCK WITH THUMB TURN ONE DOOR EDGE BOLTS ONE DOOR ALUMINUM FRAME WITH HINGES DOOR CLOSURE EACH DOOR OUTSWING ADA SILL 3'0"X7'0" 6 PANEL EMBOSSED STEEL DOOR ADA LEVEL KEY LOCK C DOOR METAL FRAME 3-4.5 HINGES OUTSWING ADA SILL ARKAY ENGINEERING INC. STRUCTURAL ENGINEERS 'Y RICHARD L. KIDDEY P.E. FLORIDA LICENSE NUMBER 37296 1 HERBY CERTIFY THAT THESE PLANS AND SPECIFICATIONS WERE PREPARED BY ME OR UNDER MY DIRECT SUPERVISION ARE IN COMPLIANCE WITH CHAPTER 16, SECTION 1609 OF THE FLORIDA BUILDING CODE 2020 7 TH EDITION AND ASCE 7-16 FOR 139 MPH WIND ZONE RISK CATEGORY II rr Ln C sn �m cq �p s caCA0 cnm�V V N� zL�IL z� do ill t] 'u a "M 00 o Y u1a°o� ua0i � u ui Q N O N Z _O (n N 5, O W a0 N N m O N N Z o O W Z Q m p p O U Z — r Z Lc) O M cV U��� ppLL04 F- W 0 (n �W U �Mw0 } N Q Z 0 0 � �QO �O-1 m Vof-i LL Q LL0� OMieo J (o W Lu U N SHEET B1 ARKAY # 19870 ►— SOUTH ELEVATION 1/411 = 1' 0" WEST ELEVATION 1/411= 1' 0" AREA VENTILATION REQUIRED - UPPER & LOWER VENTED PROVIDED 3730 S.F. ATTIC AREA / 300 = 12.44 S.F. X 144 = 1790 S.I. 1790 S.I. / 2 = 895 S.I. UPPER AND LOWER VENTILATION REQUIRED UPPER VENTILATION PROVIDED 7 OFF RIDGE VENTS AT 138 SIJEA = 968 > 895 SI. LOWER VENTILATION PROVIDED 270 FT. SOFFIT VENTS ( MIN ) AT 6.42 SI./FT = 1733 > 895 SI. 93.22' FROM SITE PLAN EAST ELEVATION 1 /411 = 1' 0" _ _ WALL HEIGHT Eo 10' 0" 99.00' ELEV BUILDING FINISH FLOOR _ 00" FROM SITE PLAN 94.29' ELEV APPROX BOTTOM OF RETENTION _ _ _ _ _ _ _ _ _ FROM SITE PLAN } Z Q 12 W H Q N 0 N Z r _O (n N 5; O W z u z 0" In z In ch N U') ch M Q O J LL Z (U r� (D w ~o cn o N W Q M N tt? Q� � } co � mV m co LL rnLL O 2 m N co M co N N } N m N i N Z o O NORTH ELEVATION 1 /4" = 11011 Q co 0 o O ARKAY ENGINEERING INC. STRUCTURAL ENGINEERS RICHARD L. KIDDEY P.E. FLORIDA LICENSE NUMBER 37296 I HERBY CERTIFY THAT THESE PLANS AND SPECIFICATIONS WERE PREPARED BY ME OR UNDER MY DIRECT SUPERVISION ARE IN COMPLIANCE WITH CHAPTER 16, SECTION 1609 OF THE FLORIDA BUILDING CODE 2020 7 TH EDITION AND ASCE 7-16 FOR 139 MPH WIND ZONE RISK CATEGORY 11 Z Z IRT Lo O M N 00 U, N 00 U)w Jcr OU=� � W U Q(DD(LLL �Mw0 } N (D Q Z_ 0 00It O m J W LL Vw-j u.Q= Ooo� J (o _ W w U N SHEET B2 ARKAY # 19870 Er a LINTELS ON THIS PROJECT ARE AS SPECIFIED ON THIS CHART UNLESS NOTED ON FLOOR PLAN BY OPENING LINTEL LOAD CHART ( 16" DEEP SECTION ) CLEAR SPAN CONCRETE U LINTEL 1' - 6" 4987 PLF (UNFILLED) 2' - 2" 3435 PLF (UNFILLED) 2' - 8" 2777 PLF (UNFILLED) T - 2" 2332 PLF (UNFILLED) 4- - 0" 1835 PLF (UNFILLED) 4V _ 6" 1624 PLF ( UNFILLED ) 5' - 2" 2739 PLF '* 6' - 2" 2271 PLF ** 7' - 0" 1987 PLF " 8'- 0" 1723 PLF ** 9' - 2" 1489 PLF ** 10, - 0" 1354 PLF ** 10, - 8" 1277 PLF ' 11' - 2" 1200 PLF ** 12' - 0" 1109 PLF ** 12' - 8" 1044 PLF ** 13' - 4" 1398 PLF " P DENOTES #5 REBAR X CONT. PLACED IN BOTTOM COURSE AND 16" DEEP BEAM POURED SOLID WITH 2500 PSI CONCRETE. ** P - DENOTES PRE STRESSED U LINTEL WITH #5 REBAR X CONT. PLACED IN BOTTOM COURSE 81 16" DEEP BEAM POURED SOLID WITH 2500 PSI CONCRETE zcf)U N In z 101, 8" O 1""1 0 O 0r%n'rIA1/l- AT rUIC IA/AI 1 IAIII 1 01 I00r%0'rTUC GI 111 f11A.1r_ rA 1.1 z � Q G7 z 0 I'- C7 w ~o wa Z M � 0 0 N Z Q Lo q o aW � mV m to fy LL 0-)LL O N co l'7 FOUNDATION PLAN 1 /411 = 1' 0" 8" X 8" X 16" KNOCK OUT BLOCK TOP COARSE WITH 1 #5 HORIZONTAL - — - — - - - - - - - - - - - REBAR TIED TO ALL VERTICAL RODS I I �8� I I I •; I I 8" PRECAST LINTEL BLOCK OVER ALL OPENINGS. 1 EACH \SIDEWALK\ll a #5 REBAR IN THIS COARSE WHENSPAN OF LINTEL OVER 57' STANDARD PRECAST DETAIL I SECURING PREHUNG TO BUCK STRIPS PER YOUR MANUFACTURES INSTRUCTIONS TO MEET WIND LOADS AND COMPRESSIONS ATTACH MINIMUM 3/4" P.T. BUCK RATINGS FOR YOUR JOB LOCATION. ALL STRIP THAT IS THE MINIMUM WIDTH ANCHOR SCREWS MUST PENETRATE BLOCK OF DOOR FRAME USING .097X1 3/8" WALL A MINIMUM OF 1 1/4" AND THERE SHALL T- NAILS MAXIMUM 10" OC. BE A MAXIMUM 1/4" SPACE BETWEEN BUCK AND DOOR JAMB CAULK DOOR FRAME PER YOUR MANUFACTURES RECOMMENDATIONS kelcm s••: ". a mol.,u rr z LL zm7 Qo ILL !' z ID ri z u' ill QQ� ua�m �a- « w Q N 0 N Z _O fn N 5; O W 00 N N N o N m 1 N Z CD O LLI Z ~ m p O -7 U z Z Nt Lo O MN UoD ��� :�LL.� p co OU=� W U ��w0 } N 1 1 1 1 I 1 6X6 PT POST EMBED IN 24"X24"X24" DEEP - -� - -' CONCRETE. POST TO EXTEND TO401/2" ; ABOVE FINISH FLOOR OF WOOD DECK TYPICAL ALL POST LOCATIONS a L 1 L 1 1 1 I 1 1 1 1 1 1 I I 1 I[..0 I N Z 0 ----------------------- ---- — — r------i---i--------------r----r----- r-- -- r �--------------- r-- - r--------------i-- SECURING WINDOW TO BUCK STRIPS PER ATTACH MINIMUM 3/4" P.T. BUCK STRIP YOUR MANUFACTURES INSTRUCTION TO MEET 4' 0" S' 9'/," ' 5' 97/a" 5' 9Y.- 5' 97/e" J < O THAT IS THE MINIMUM WIDTH OF YOUR WIND LOAD AND COMPRESSION RATINGS FOR J WINDOW FRAME USING .097 X 1 3/8" YOUR JOB LOCATION. ALL ANCHOR SCREWS M T- NAILS MAXIMUM 10" OC MUST PENETRATE BLOCK WALL A MINIMUM OF W 1 1/4" AND THERE SHALL BE A MAXIMUM 1/4" W r^ SPACE BETWEEN BUCK AND WINDOW FRAME v J V�� Q J LINT WOOD DECK NN I.L FOUNDATION PLAN 1/4" = 1' 0" J m _ w CO a 1 UJ N CAULKED WINDOW PER YOUR ARKAY ENGINEERING INC. U) WINDOW MANUFACTURES SPECIFIC STRUCTURAL ENGINEERS RECOMMENDATIONS TO MEET WIND I LOAD AND COMPRESSION RATINGS FOR YOUR JOB LOCATION , 1 t/a RICHARD L. KIDDEY P.E. BLOCK WINDOW ATTACHMENT DETAIL FLORIDA LICENSE NUMBER 37296 SHEET NOT TO SCALE I HERBY CERTIFY THAT THESE PLANS AND SPECIFICATIONS �] WERE PREPARED BY ME OR UNDER MY DIRECT SUPERVISION J ARE IN COMPLIANCE WITH CHAPTER 16, SECTION 1609 OF THE FLORIDA BUILDING CODE 2020 7 TH EDITION AND ASCE 7-16 FOR 139 MPH WIND ZONE RISK CATEGORY 11 ARKAY # 19870 zz M 01-0 Q 0 tn o 1/2" CDX OR 7/16" OSB ROOF SHEATHING NAILED 1/2" CDX OR 7/16" OSB ROOF SHEATHING NAILED z PER ROOF SHEATHING DETAIL WITH 8D NAILS, USE PER ROOF SHEATHING DETAIL WITH 8D NAILS, USE >0 cl) z U ti STEEL PLYCLIPS . USE GAF UNDERLAYMENT AND STEEL PLYCLIPS . U5E GAF UNDERLAYMENT AND r` APPLY HOP.20NTAL PEEL L C7 W CD STICK FLASHING OVER GAF SHINGLES GAF SHINGLES � r•l � p N FLANGE VERIFY NSTALL.W/ LU Q c, z 0 U SELECTED MANUFACT. RECOMMENDATIONS Z Q C14 WOOD FRAME OR OR CM FRAME A Q d (h CMU WALL OR CMU WALL ENGINEERED ROOF TRUSSES ENGINEERED ROOF TRUSSES W mElc BUILDING m U WRAP AT WOOD SEE ROOF TRUSS PLAN SEE ROOF TRUSS PLAN FRAME LOCATIONS iX4 #2 PINE @ 24" OC ATTACHED TO 1X4 #2 PINE @ 24" OC ATTACHED TO in rn LL WINDOW FLANGE SECURED TO WINDOW RANGE SECURED TOP OF BOTTOM CORD OF TRUSSES TOP OF BOTTOM CORD OF TRUSSES O WOOD BUCK AS PER WINDOW TO WOOD BUCK AS PER WITH 2-1 OD NAILS WITH 2-10D NAILS MANUFACTURES ^ WINDOW MANUFACTURES j� 2X4 #2 SPRUCE SUB FASCIA WITH 2X4 #2 SPRUCE SUB FASCIA WITH RECOMMENDATIONS (—/\J RECOMMENDATIONS I— \ WOOD FRAME ALUMINUM DRIP, FASCIA AND SOFFIT ALUMINUM DRIP, FASCIA AND SOFFIT = L-11/ OR CMU WALL SEE SOFFIT DETAIL SEE SOFFIT DETAIL APPLY SILL PEEL L STICK FLASHING N OVER FLANGE VERIFY 00 INSTALLATION W/SEIECTEb @7 MANUFACT. APPLY VERTICAL PEEL WINDOW FLANGE SECURED TO SINGLE KNOCKOUT LINTEL BLOCK WITH 1-#5 SINGLE KNOCK OUT LINTEL BLOCK WITH 145 RECOMMENDATIONS 6 STICK FLASHING OVER WOOD BUCK AS PER WINDOW - HORIZONTAL REBAR TIED TO ALL THE VERTICAL HORIZONTAL REBAR TIED TO ALL THE VERTICAL FLANGE VERIFY FACT.l. W/ MANUFACTURES RODS POURED WITH MINIMUM 2500 PSI CONCRETE RODS POURED WITH MINIMUM 2500 PSI CONCRETE SELECTED MANUFACT. RECOMMENDATIONS RECOMMENDATIONS - NOTE: STEP #1 STEP #2 STEP #3 r m � CONTRACTOR TO (LASH AND SEAL ALL �MINDOW AND DOOR OPENINCsS PER THE MANUFACTURER'S RECOMMENDATION AND SMALL PROVIDE A COMPLETE WATER TIGHT SEAL. 8" PRECAST LINTEL OVER ALL OPENINGS 8" PRECAST LINTEL OVER ALL OPENINGS ' m FLASHING NOTES:co o PROVIDE CORROSION-RESISTTVE FLASHING IN THE EXTERIOR WALL ENVELOPE TO PREVENT ENTRY OF WATER INTO THE WALL CAVITY OR PENETRATION OF WATER TO THE BUILDING F- STRUCTURAL FRAMING COMPONENTS. THE FLASHING SHALL EXTEND TO THE SURFACE OF THE EXTERIOR WALL FINISH AND SHALL BE INSTALLED TO PREVENT WATER FROM REENTERING CMU OPTION: N _ _ THE EXTERIOR WALL ENVELOPE. APPROVED CORROSION -RESISTANT FLASHINGS SHALL BE INSTALLED AT THE FOLLOWING LOCATIONS: SEAL FROM FACE OF BLOCK WALL EDGE TO o = 0 2 Z O 1[V FRAME EDGE OF WINDOW WITH DRYLOCK SEALANTLL 1. AT THE TOP Of ALL EXTERIOR �ND9WS AND DOOR OPENINGS IN SUCH A MANNER AS TO Be LEAK -PROOF, EXCEPT THAT SELFFLASHNG WINDOWS HAVING CONTINUOUS LAP NO FINISH ON INTERIOR OF � NO FINISH ON INTERIOR OF _j >L 70 OF NOT LESS THAN 1 1/8 INCH OVER THE SHEATHING MATERIAL AROUND THE PERIMETER OF THE OPENING. INCLUDING CORNERS, DO NOT REQUIRE ADDITIONAL WALL TILL BUILDING LEASED 0 ¢ WALL TILL BUILDING LEASED 0 Q v) L z 3 z 2 DECORATIVE a DECORATIVE 3 6 � FLASHING: JAMB FLASHING MAY ALSO BE OMInED W HEN SPECIFICALLY APPROVED BY THE BUILDING OFFICIAL. c a IL AT THE INTERSECTION OF CHIMNEYS OR OTHER MASONRY CONSTRUCTION WITH FRAME OR STUCCO WALLS. WITH PROJECTING LIPS ON BOTH SIDES UNDER STUCCO COPINGS. CEMENTITIOUS °D CEMENTITIOUS co CL +JO 3. UNDER AND AT THE ENDS OF MASONRY, WOOD OR METAL COPINGS AND SALE. FINISH U- FINISH U. Z 4.CON nN000SLYABOVE ALI PROJECTING WOOD TRIM. VINYL INSULATED WINDOWS a VINYL INSULATED WINDOWS d 5. WHERE R PORCHES. DECKS OR STAIRS ATTACH TO A WALL OR FLOOR ASSEMBLY OF WOOD -FRAMED CONSTRUCTION. MASONRY SILL 0 MASONRY SILL !D O Q.. 6. A WALL AND ROOF INTERSECTIONS. EXTERIOR DOOR & WINDOW FLASHING o �v #5 VERTICAL REBAR @ 48" OC WITH THE CELLS #5 VERTICAL REBAR @ 24" OC WITH THE CELLS POURED SOLID WITH MINIMUM 2500 PSI CONCRETE POURED SOLID WITH MINIMUM 2500 PSI CONCRETE tL MINIMUM 25" LAP MINIMUM 25" LAP UI PROPOSED F.F. 99.0' PROPOSED F.F. 99.0' (a u d I W- 2X2 WOOD VERTICAL BLOCKING ATTACHED TO FACE OF EACH TRUSS WITH (2) 12D NAILS AND EXTENDS DOWN TO SOFFIT LOCATION 4" TO 8" FASCIA INSTALL BEHIND EAVE DRIP SECURE SOFFIT TO BOTTOM OF FASCIA WITH 7/8" STAPLE. SECURE FASCIA WITH 1 3/4" TRIM NAIL 16" OC 2X2 CONTINUOUS BATTEN ATTACHED TO VERTICAL 2X2 BLOCKING WITH 1- 12D NAIL v -v ROOFTRUSS INSTALL CONTINUOUS F CHANNEL TO FACE OF BLOCK WALL WITH CONTINUOUS 1X2 WOOD BLOCKING WITH 1 5/8" MASONRY FASTENERS 12" OC BLOCK WALL ALUMINUM SOFFIT PANEL SECURE PANEL TO 2X2 BLOCKING WITH 7/8' STAPLE OR #8X1" SCREWS MAX 24" 8"OC 139 MPH WIND SPEED OR LESS BLOCK WALL SOFFIT DETAIL NOT TO SCALE 5/4X6 PT DECK BOARDS ATTACHED EACH JOIST WITH 348X2 1/2" GALV DECK SCREWS WOOD DECK FLOOR FRAMING PLAN 1/411= 1' O" v v 5/4X6 PT D SEE DECK 6X6 PT POST EMBE CONCRETE. POST 1 ABOVE FINISH FLO( TYPICAL ALL POST, KNOCK LINTEL BLOCK @ 24" OC WITH 1 - #5 REBAR HORIZONTAL TIED TO ALL VERTICAL RODS FILL ALL CELLS OF LOWER WALL SOLID WITH MINIMUM m 2500 PSI CONCRETE c v � TOP OF RETENTION 0 4 - #5 REBAR EQUALLY SPACED ON CHAIRS #5 VERTICAL REBAR @ 48" OC WITH 24" RETURN #5 REBAR @ 16" OC 3-0- WALL SECTION DETAIL "A" NOT TO SCALE 111C L rN I trt Ur I r1r rub I 2-0- DECK CUT SECTION DETAIL NOT TO SCALE 3 3/4" APART KNOCK LINTEL BLOCK @ 24" OC WITH 1 - #5 REBAR HORIZONTAL TIED TO ALL VERTICAL RODS E&M-MOM M� TOP 4 - #5 REBAR EQUALLY SPACED ON CHAIRS #5 REBAR @ 16' OC 3' 6" WALL SECTION DETAIL "B" NOT TO SCALE ROOF EDGE GABLE END PARTIAL ROOF PLAN ZONE O 1 8dRING SHANK NAILS AT 6" O.C. AT EDGES 8dRING SHANK NAILS AT 6" O.C. INTERMEDIATE ZONES 2O 3O SIRING SHANK NAILS AT 6" O.C., 4" O.C. AT ROOF EDGES, RIDGE LINE, OR GABLE ENDWALL NOTE: END JOINTS FOR SHEATHING SHALL BE STAGGERED AND OCCUR OVER A FRAMING MEMBER. ROOF SHEATHING NAILING NOT TO SCALE FILL ALL CELLS OF LOWER WALL SOLID WITH MINIMUM 2500 PSI CONCRETE 0 #5 VERTICAL REBAR @ 24" OC WITH 24" RETURN 5'-0' OI m W F- p N z �= _O TA c1 5; CD W 00 N N m O 04 04 z o z m o O A z qqt Lc) O M (V ULo-iC) J cM _ co O � W L) coU }_ �MLLI0 } N fY ti0 r� J� LU ARKAY ENGINEERING INC. STRUCTURAL ENGINEERS RICHARD L. KIDDEY P.E. 5-I FLORIDA LICENSE NUMBER 37296 1 HERBY CERTIFY THAT THESE PLANS AND SPECIFICATIONS WERE PREPARED BY ME OR UNDER MY DIRECT SUPERVISION ARE IN COMPLIANCE WITH CHAPTER 16, SECTION 1609 OF THE FLORIDA BUILDING CODE 2020 7 TH EDITION AND ASCE 7-16 FOR 139 MPH WIND ZONE RISK CATEGORY 11 V Q Z �0_/ 0 � N _ O 0 Co C LL C) J LL Q = O ap J ( _ W W V N SHEET B4 ARKAY # 19870 r�M zcr) z 0~ 101, 8" 0 1 W >N z Q G7 Z (!) ti W ~ o 0 MITZ � (n w f� N Q c;, 0 N q ZU) J 04 Lo aW =) m m U m Ly LL rnW �O OD ch 0 0 M M a En Lo M C USE lU SIMPSON HETA20 STRAP AT EACH SIDE USE (U SIMPSON HETA20 STRAP AT EACH SIDE OF TRUSS AT EACH END POURED IN BOND BEAM. OF TRUSS AT EACH END POURED IN BOND BEAM, FILL NAIL HOLES WITH IODXI In" NAILS FILL NAIL HOLES WITH IODXI 1/2" NAILS _7 71 1`� tt!_ ---- ----- --- ----- ---- USE (1) SIMPSON HETA20 STRAP AT ONE SIDE OF ALL ---- ----- --- ---- ROOF TRUSSES AT BLOCK WALL OR BEAM THAT DOES 11 NOT HAVE A SPECIFIC STRAP CALLED OUT 20' 4" 11' 4" 38' 4" 11' 4" 20' 4" 101, 8" Jv ROOF TRUSS PLAN 1 /411 = 1' O" 2x4 CROSS -BRACING @ RIDGE I 20'-0" MAX IIIIIIIy111� 11!�� ilk111�11�1��� milpolm. IN I��.��� ���11111��11�11��:= 1111111 II�1���_ SEE TRUSS SYSTEM ENGINEERING DRAWINGS FOR ANY ADDITIONAL BRACING OR CROSS BRACING REQUIREMENTS REQ. MINIMUM TRUSS BRACING TOPIBOTTOM CHORD GABLE TEND BRACING @ 48" O.C. MAX FOR THE FIRST 4 ROWS OF TRUSSES (MIN 2X4 ) w J m C� CONT. BOTTOM CHORD BRACING (1"x4" MIN.) @ 10'-0" MAX. 2" X 8" RIDGE CONT. 2"X4" USP "RT3" OR SIMPSON "H3" HURR. STRAP @ 48" O.C. TYP. 2"X4" NAILERS (TYP.) 2"X4" VERTICAL SCAB @ 48" O.C. (MAX.) CONN. W/ 4-16D NAILS @ TOP & USP "RT3" OR SIMPSON "H3" HURRICANE CLIP AT BOTTOM. F/� 2" X 6" (#2 YELLOW PINE) / RAFTERS @ 24" O.C. USP "RT3" OR SIMPSON "H3" HURR. STRAP @ EACH END END NOT EXPOSED TO WIND 2" X 8" RIDGE BOARD VERT. SCAB BEVEL CUT TYP. CONT.2"X4" - NAILER TYP. (2-16D NAILS PER TRUSS) USP "RT3" OR SIMPSON "H3" HURR. STRAP @ 48" O.C. TYP. ROOF VALLEY DETAIL NOT -TO -SCALE SIMPSON H3 FRAMING ANCHOR TYP. r— ROOF SHEATHING SECTION "A" -"A" RUSSES BELOW SHEATHED RIOR TO VALLEY FRAMING ISTALLATION. X 6" (#2 YELLOW PINE) VALLEY FRAMING (TYP.) COMMON TRUSS 4-16D TOE NAILS @ RIDGE BOARD END PROVIDE MINIMUM 16" 26 GA VALLEY FLASHING AT ALL ROOF CHANGES AND SIDE WALL AREAS PER FBC 107.2.5 /R703.7.5.703.8., 903.2 AND 905 PLACE ROOF CEMENT COATING AT ROOF DECKS EDGES OF FLASHING AND ALL LAPS. NAIL FLASHING WITH 1 1/2" ROOF NAILS 12" OC 0 0 ° 0 0 0 O O ° o O 0 ° o ° o 0 0 0 ° SIDE WALLS OR CHIMNEY WALLS MINIMUM 8"X8" 26 GA ANGLE FLASHING OR STEP FLASHING, SEE NOTE ABOVE ROOF DECK AT SIDE WALLS TYPICAL ROOF FLASHING DETAIL NOT TO SCALE ARKAY ENGINEERING INC. STRUCTURAL ENGINEERS 1n RICHARD L. KIDDEY P.E. 7j FLORIDA LICENSE NUMBER 37296 1 HERBY CERTIFY THAT THESE PLANS AND SPECIFICATIONS WERE PREPARED BY ME OR UNDER MY DIRECT SUPERVISION ARE IN COMPLIANCE WITH CHAPTER 16, SECTION 1609 OF THE FLORIDA BUILDING CODE 2020 7 TH EDITION AND ASCE 7-16 FOR 139 MPH WIND ZONE RISK CATEGORY 11 r M r c cq 2cqo U CA IL z '� o zmo to $ G :E 2ra ttoc W F- Q N 0 N Z O r- co N 5 O W co N !Y N N mCD N � N Z O LLI O Z H m p p Oo U Z Z O M N co L) Lf)LJLN cr JZ Go M_ 0 U) LLI U T } QabaLL } N V Q z �0_// O -1 m jX LL L) ui LL 0 O M J ( a w w N SHEET B5 ARKAY # 19870 zcv) z 0� Q 0 o >0LL cl G7 Z L) ti (� W p Vi W QDN z N pq 0 19 Z a� Q o aW oho U 00 M u- �O C6 N cc ch z� Oz a do wwcc r� �g N aZ aZ Ym t0 2a w �z 03 m A cli N LL21 3� /�zK r Lp \ MINIMUM TEMPORARY ELECTRICAL SHOWN j u ` \ TILL SPACES ARE LEASED. ELECTRICAL TO JU \ BE INSTALLED IN CONDUIT Q r Q 0 y(all(v- ou / ccC6 \ w 22 —ad)oc - w p N Z EXIT EXIT O El (4 N > O W FI , FI i MINI.`�------------------------- :'■ .`� ------------------------- co Of N N I I I I 0) CV CV SIDE WALK SIDE WALK I coN Ix Z O O I W Z I L- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - UNIT #1 UNIT #2 OFFICE AREA 1575.8 ELECTRICAL PLAN 1/4 go = 1 o On OFFICE AREA 1575.8 U ENTRY 45.3 ENTRY 45.3 Z Z d TOTAL 1621.1 TOTAL 1621.1 O cci C �U-)LJLN 0 00 OU)=� wW U Q(oal"i 2MWO } N ELECTRICAL RISER DIAGRAM GENERAL LOADS O� TYPE OF LOAD 3- 3/0 CU 1-1/0 CU LIGHTING LOAD 1621.1 SQ FT X 2 VA 4392 O 2" PVC OUTLET & MISC ALLOWANCE 15000 Q. HVAC HEAT 6000 320A K BASE SINGLE PHASE TOTAL VA 25392 PANEL M B TOTAL VA 25392 VA METER SOCKET 200 AMP CONVERT VA TO AMPS O ❑ 25392 DIVIDED BY 240 VOLTS =106 AMPS IL 0 0 30 ELECTRICAL LEGEND Z 0 42 CIR ��// Q ix SWITCH � EXTERIOR WALL LIGHT O �O-1 1/0CU 110V m ® FLUORESCENT WP 110 V U J WATERPROOF J OUTLET T ELECTRICAL PANEL LLco 2 RUNS EA WATER LINE - O 3- 3/0 CU FOOTER STEEL IF AVAILABLE GROUND ROD lloEXIT EMERGENCY /EXIT COMBO co 1- 1/0 CU LIGHT WITH BATTERY B.U. .I 2" PVC W CONCRETE ENCASED "UFER" GROUND WIRE FORM REBAR TO ELECTRICAL PANEL PER N.E.C. r 1 N ELECTRODE REQUIRED PER ARKAY ENGINEERING INC. U) CURRENT N.E.C. AND MUST STRUCTURAL ENGINEERS BE INSPECTED PRIOR TO CONCRETE PLACEMENT RICHARD L. KIDDEY P.E. FLORIDA LICENSE NUMBER 37296 SHEET I HERBY CERTIFY THAT THESE PLANS AND SPECIFICATIONS E 1 WERE PREPARED BY ME OR UNDER MY DIRECT SUPERVISION ARE IN COMPLIANCE WITH CHAPTER 16, SECTION 1609 OF THE FLORIDA BUILDING CODE 2020 7 TH EDITION AND ASCE 7-16 FOR 139 MPH WIND ZONE RISK CATEGORY 11 ARKAY # 19870 A. r,j, ap 6�96 6G58 6c32{ bb �� 2)ro-f 4 C�