HomeMy WebLinkAbout6911 Gall Blvd (4)ENPHASE IQ8 Commercial Easy to install ight • Lightweight and compact with Microinverters plug -and -play connectors Power line communication (PLC) between components The high-powered, smart grid -ready Enphase IQ8P-3P and Faster installation IQ8H-3P Microinverters are specifically designed for 208 V three- phase interconnection for small commercial solutions. High productivity and reliability Each microinverter integrates with the IQ Gateway Commercial 2 More than one million cumulative and the Enphase App monitoring and analysis software. hours of testing With simplified design, improved energy harvesting, and advanced Class II double -insulated enclosure monitoring, microinverters offer true peace of mind during operation Optimized for the latest high - and maintenance. powered PV modules Smart Grid Ready Complies with the latest advanced 'alsegrid support Remote automatic updates for the latest grid requirements Configurable to support a wide range of grid profiles The IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power -on testing, enabling Enphase to Meets CA Rule 21(UL 1741-SA) provide an industry -leading warranty of up to 25 years.' and IEEE 1547 (UL 1741-SB) requirements 25-year warranty is valid, provided an Internet -connected IQ Gateway is installed. © 2023 Enphase Energy. All rights reserved. Enphase, the e and CC logos, IQ and certain other marks listed at ht ps//enphase_com/t ademark-usa�e�uidelines are trademarks of Enphase Energy, Inc. in the US and other countries. Data subject to change. IQ8P-3P-H-DSH-00236-2.0-EN-US-2023-11-16 IQ8 Commercial Microinverters Commonly used modules for pairing' Module compatibility' Maximum input DC voltage Peak power tracking voltage Operating range Min./Max. start voltage Max. DC continuous current (module Imp) Max. input DC short-circuit current Max DC short circuit current (module IJ Overvoltage class DC ports DC port backfeed current PV array configuration Peak output power Maximum continuous output power Nominal (L-L) voltage/range' Maximum continuous output current Nominal frequency Extended frequency range Maximum microinverters per 20A 3 Phase branch circuit3 Overvoltage class AC port Power factor setting Power factor (adjustable) Peak efficiency CEC weighted efficiency Ambient temperature range Relative humidity range DC connector type4 Dimensions (H x W x D) Weight Cooling Approved for wet locations Enclosure Environmental category/UV exposure rating W V V V V A A A A VA VA V A Hz Hz 380-640 320-540 54-cell/108 half -cell, 60-cell/120 half -cell, 66-cell/132 half -cell and 72-cell/144 half -cell 63 35.5-53 28.5-45 16-63 21/63 14 25 20 I 0 1 x 1 ungrounded array; no additional DC side protection required; AC side protection requires max 20A per branch circuit 480 384 475 380 208/183-229 220/198-242 208/183-229 2.28 2.16 1.83 60 47-68 12 12 15 III 1.0 0.85 leading ... 0.85 lagging 97.8 97.7 97.5 96.5 220/198-242 1.73 15 -40'C to +65°C (-40'F to +149*F) 4% to 100% (condensing) Enphase EN4 bulkhead; ECA-EN4-S22-12: EN4 (TE PV4-S SOLARLOK)150 mm/5.9" to Staubli MC4 adapter cable pair (Default supply)= 265 mm x 200 mm x 35 mm (10.4" x 7.9" x 1.4") without bracket 1.6 kg (3.5 lb) Natural convection Yes Class 11 double -insulated, corrosion resistant polymeric enclosure Outdoor—NEMA Type 6AP67 Communication Power line communication (PLC) Monitoring Enphase App monitoring and analysis software. Both options require installation of an IQ Gateway Commercial 2. CA Rule 21(UL 1741-SB). UL 62109-1. UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO.107.1-01. This product is UL- Compliance Listed as PV rapid shutdown equipment and conforms with NEC 2014, NEC 2017, and NEC 2020 section 690.12 and C22.1-2018 Rule 64-218 rapid shutdown of PV systems for AC and DC conductors, when installed according to manufacturer's instructions. (1) Pairing PV modules with wattage above the limit may result in additional clipping losses. See the compatibility calculator at httks://lin_k_enphasernm/ module-con,paY_b_ 6ty. (2) Nominal voltage range can be configured if required by the utility. (3) Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. (4) Enphase IQ8P-3P and I08H-3P Microinverter bulkhead and adapter cable male, female DC connectors must only be mated with the identical type and manufacturer brand of male/female connector. (5) Qualified per UL subject 9703. 1Q8P-3P-H-DSH-00236-2.0-EN-US-2023-11-16 TAMPA BAY 0 �, RAVOWG'fK9_MHK 5TATE 6002 E. ADAMO DR., TAMPA, FL,33619 PH. NO.: (813) 398-3687 Email : info@tampabaysolar.com REVISIONS DESCRIPTION DATE REV LEC 1 CHANGES 01/15/2024 41 S GIVEN A 01/17/2024 #2 CHANGEDIN\/FPTrP TYPE 02/13J2024 #3 CALCULATION ADDED 02/15/2024 #4 SIGNATURE WITH SEAL DATE: 02/15/2024 PROJECT NAME & ADDRESS V N _Z LO J � M M i= > J Q m m LL J J J J �_ W U � C N O U SHEET NAME EQUIPMENT SPECIFICATION SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-8 ENPHASE DATA SHEET . IQ Gateway Commercial 2 Three-phase communications gateway with integrated, revenue -grade PV production metering (±0.5%) and ENV2-IQC2-AM3-3P — optional consumption monitoring (±2.5%). Includes three 400 A continuous rated Production CTs. This IQ Gateway Commercial 2 works only with the 108 Commercial Microinverters. Enphase Mobile Connect CE LLMODEM-M1-06-SP-O5 C E LLM ODE M-Mt-06-AT-05 Consumption monitoring CT-600-SPLIT (order three or six, as needed) Plug -and -play industrial -grade cellular modem with a five-year data plan (expandable to 12 years). Available in the — United States, Canada. Mexico, Puerto Rico, and the U.S. Virgin Islands, where there is adequate cellular service in the installation area. — Split -core current transformers enable consumption metering Number of microinverters polled MECHANICAL AND ELECTRICAL DATA — Up to 276 Power requirements — 208 Y/120 VAC three-phase Max 20 A overcurrent protection is required Typical power consumption W 5 Rated frequency Hz 60 Dimensions (W x H x D) cm 21.3 x 12.6 x 4.5 (8.4•' x 5" x 1.8") IQ Gateway Commercial 2 Smart Weight oz 17.6(498g) The IQ Gateway Commercial 2 delivers solar production and energy consumption data Enables web -based monitoring and Ambient temperature range C -40°C to 651C (-40°F to 149'0 control -40°C to 46°C (-40°F to 115°F) if installed in an enclosure to Enphase App, the monitoring and analysis software for comprehensive, remote maintenance and management of I08 Commercial Microinverter based PV systems. Supports bidirectional communications Environmental rating — IP30. For installation indoors or in an NRTL-certified, NEMA-type3R enclosure. for remote upgrades Altitude In Up to 2,000 (6,560 ft) With integrated revenue -grade production metering and optional consumption Supports power export limiting and monitoring, the IQ Gateway Commercial 2 is the platform for total energy management zero -export applications - Capable of measuring 400 A of continuous current with 0.5% accuracy - Accuracy of ±0.5% for revenue grade production metering (ANSI C12.20 certified) and integrates with the I08 Commercial Microinverters. Production CTs — - The internal aperture measures 43 mm and can support cables up to a maximum size of 1.000 KCMIL Simple conductors - UL2808 certified Easy system configuration using Enphase - For electrical services up to 600 A. with parallel runs up to 1200 A Installer App - Aperture of 50 mm x 50 mm and can support cables up to a maximum size of 300 KCMIL conductors Flexible networking with Wi-Fi and Consumption CTs _ - Service entrance rated with UL2808 certification Ethernet - Rated for pollution degree 3 - Accuracy of ±2.5% for consumption monitoring - CT wire insulation rating of 600 V Reliable COMMUNICATION Designed for installation indoors or Integrated Wi-Fi — 802.11b/g/n (2.4 GHz. 5 GHz). for connecting the Enphase Cloud via the internet IQ8 Commercial Series Microinverters outdoors in an enclosure Extra high-powered, smart grid -ready microinverters designed to match larger format 5-year warranty Wi-Fi range (recommended) ft 32.8 commercial PV modules. Optional, 802.3, Cat5E (or Cat 6) UTP Ethernet cable (not included) for connecting to the Enphase Cloud via the Ethernet _ internet Mobile Connect — CELLMODEM-Mt-06-SP-05, CELLMODEM-Mt-06-AT-05 (to be purchased separately) Digital 1/0 — Digital input/output for grid operator control USB 2.0 — For Mobile Connect Access point (AP) mode — For a connection between the IQ Gateway and a mobile device running the Enphase Installer App Metering ports — Up to two Consumption CTs and one Production CT Power line communication (PLC) kHz 90-110 (Class B) to microinverters Web API = Refer to httos://developer-v4.enpbase.com U Local API Refer to guide for local API LISTEDLED indicators — From top to bottom: Cloud connectivity. Wi-Fi access point mode. PV production state. PLC communications state Configured via — Enphase Installer App and Enphase Installer Platform IQ Gateway Commercial 2-DSH-00212-2.0-EN-US-2023-10-31 IQ Gateway Commercial 2-DSH-00212-2.0-EN-US-2023-10-31 TAMPA BAY 11jWMINI I IHE -'_ 1-"i SI i; ��- 6002 E. ADAMO DR., TAMPA, FL,33619 PH. NO.: (813) 398-3637 Email : info@tampabaysolar.com REVISIONS_ DESCRIPTION DATE` _ REV ELECTRICAL CHANGES 01l15I2024 #1 SE BAC GIVEN 01/1712024 #2 CHANGED 02/13/2024 #3 CALCUAD LATION 02/1512024 #4 SIGNATURE WITH SEAL DATE: 02/15/2024 PROJECT NAME & ADDRESS V N _z L(� 0 L0 J -M 0 C7 1 LL Q m J J W U (D = Q C 0) � N O U SHEET NAME EQUIPMENT SPECIFICATION SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-9 SCOPE OF WORK: TO INSTALL A ROOF MOUNTED SOLAR PHOTOVOLTAIC SYSTEM AT THE OWNER COMMERCIAL BUILDING LOCATED AT 6911 GALL BLVD., ZEPHYRHILLS, FL 33542, USA. THE POWER GENERATED BY THE PV SYSTEM WILL BE INTERCONNECTED WITH THE UTILITY GRID THROUGH THE EXISTING ELECTRICAL SERVICE EQUIPMENT. THE PV SYSTEM DOES NOT INCLUDE STORAGE BATTERIES SYSTEM SUMMARY 96 MISSION SOLAR MSE395SX9R (395W) MODULES 96 ENPHASE IQ8H-3P-72-E-US MICROINVERTERS PROJECT DESCRIPTION: 96 X 395 MISSION SOLAR MSE395SX9R (395W) MODULES ROOF MOUNTED SOLAR PHOTOVOLTAIC MODULES SYSTEM SIZE: 36.48 kW AC STC SYSTEM SIZE:37.92 kW DC STC ARRAY AREA: ROOF#1 - 1038.24 SQ FT ARRAY AREA: ROOF#2 - 1038.24 SQ FT AUTHORITIES HAVING JURISDICTION BUILDING : HILLSBOROUGH COUNTY ZONING : HILLSBOROUGH COUNTY UTILITY : N/A GENERAL NOTES: • THESE CONSTRUCTION DOCUMENTS HAVE BEEN BASED ON FIELD INSPECTIONS AND OTHER INFORMATION AVAILABLE AT THE TIME. ACTUAL FIELD CONDITIONS MAY REQUIRE MODIFICATIONS IN CONSTRUCTION DETAILS. • ARCHITECT HAS NOT BEEN RETAINED TO SUPERVISE ANY CONSTRUCTION OR INSTALLATION OF ANY EQUIPMENT AT SITE. • CONTRACTOR SHALL FURNISH ALL LABOR, MATERIAL, EQUIPMENT, TOOLS, OBTAINS ALL PERMITS, LICENSES AND PAY ALL REQUIRED FEES AND COMPLETE INSTALLATION. • CONTRACTOR HAS THE FULL RESPONSIBILITY TO CHECK AND VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS. ANY DISCREPANCIES SHALL BE REPORTED TO THE ENGINEER BEFORE PROCEEDING WITH THE WORK. ANY WORK STARTED BEFORE CONSULTATION AND ACCEPTANCE BY THE ENGINEER SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR AND SHALL BE SUBJECT TO CORRECTION BY THEM WITHOUT ADDITIONAL COMPENSATION. • DAMAGE CAUSED TO THE EXISTING STRUCTURE, PIPES, DUCTS, WINDOWS, WALL, FLOORS, ETC. SHALL BE REPAIRED TO THE ORIGINAL CONDITION OR REPLACED BY THE CONTRACTOR AT NO ADDITIONAL COST. • THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR THE PROPER INSTALLATION AND COMPLETION OF THE WORK WITH APPROVED MATERIALS. • NO CHANGES ARE TO BE MADE WITHOUT THE CONSULTATION AND APPROVAL OF THE ARCHITECT. • CONTRACTOR SHALL OBTAIN BUILDING PERMIT. NO WORK TO START UNLESS BUILDING PERMIT IS PROPERLY DISPLAYED. • ALL WORKMANSHIP AND MATERIALS SHALL BE OF FIRST QUALITY AND IN COMPLIANCE WITH THE REQUIREMENTS OF THE FL BUILDING CODE, THE DEPARTMENT OF ENVIRONMENTAL PROTECTION AND ALL PERTINENT AGENCIES. • IT IS ESSENTIAL THAT ALL WORK PROCEED WITH THE MAXIMUM COOPERATION OF ALL PARTIES AND WITH MINIMUM INTERFERENCE TO THE OCCUPANTS WITHIN THE BUILDING. THE OWNER'S DIRECTIONS IN THIS REGARD SHALL BE FULLY COMPLIED WITH. • ALL EXPOSED PLUMBING, HVAC, ELECTRICAL DUCTWORK, PIPING AND CONDUITS ARE TO BE PAINTED BY GENERAL CONTRACTOR. • THE CONTRACTOR SHALL PERFORM THE WORK IN STRICT CONFORMANCE WITH THE LOCAL LAWS, REGULATIONS AND THE NATIONAL ELECTRIC CODE. • THE CONTRACTOR SHALL OBTAIN ALL PERMITS, APPROVALS, AFFIDAVITS, CERTIFICATIONS, ETC. AND PAY ALL FEES AS REQUIRED BY THE LOCAL AUTHORITIES. • CONTRACTORS SHALL OBTAIN FIRE CERTIF. UPON COMPLETION OF WORK. APPLICABLE CODES & STANDARDS: 2023 FLORIDA BUILDING CODE: BUILDING 2023 FLORIDA BUILDING CODE: RESIDENTIAL 2023 FLORIDA BUILDING CODE: EXISTING BUILDING 2020 NATIONAL ELECTRICAL CODE (NEC) DESIGN CRITERIA WIND SPEED 138 MPH VULT EXPOSURE CATEGORY C RISK CATEGORY II MOUNTING METHOD ROOF MOUNT GROUND SNOW LOAD 3 PSF WIRING AND CONDUIT NOTES: • ALL CONDUIT SIZES AND TYPES, SHALL BE LISTED FOR ITS PURPOSE AND APPROVED FOR THE SITE APPLICATIONS • ALL PV CABLES AND HOMERUN WIRES BE #10AWG *USE-2, PV WIRE, OR PROPRIETARY SOLAR CABLING SPECIFIED BY M FR, OR EQUIVALENT; ROUTED TO SOURCE CIRCUIT COMBINER BOXES AS REQUIRED • ALL CONDUCTORS AND OCPD SIZES AND TYPES SPECIFIED ACCORDING TO [NEC 690.8 (A)(1) & (13)(1)], [NEC 240] [NEC 690.7] FOR MULTIPLE CONDUCTORS • ALL PV DC CONDUCTORS IN CONDUIT EXPOSED TO SUNLIGHT SHALL BE DERATED ACCORDING TO [NEC TABLE 310.15 (13)(2)(C)] BLACK ONLY** • EXPOSED ROOF PV DC CONDUCTORS SHALL BE USE-2, 900C RATED, WET AND UV RESISTANT, AND UL LISTED RATED FOR 60OV, UV RATED SPIRAL WRAP SHALL BE USED TO PROTECT WIRE FROM SHARP EDGES • 4-WIRE DELTA CONNECTED SYSTEMS HAVE THE PHASE WITH THE HIGHER VOLTAGE TO GROUND MARKED ORANGE OR IDENTIFIED BY OTHER EFFECTIVE MEANS • ALL SOURCE CIRCUITS SHALL HAVE INDIVIDUAL SOURCE CIRCUIT PROTECTION • VOLTAGE DROP LIMITED TO 2% • AC CONDUCTORS >4AWG COLOR CODED OR MARKED: PHASE A OR L1- BLACK, PHASE B OR L2- RED, PHASE C OR L3- BLUE, NEUTRAL- WHITE/GRAY ELECTRICAL NOTES: • THE EQUIPMENT AND ALL ASSOCIATED WIRING AND INTERCONNECTION SHALL BE INSTALLED ONLY BY QUALIFIED PEOPLE. A QUALIFIED PERSON IS ONE WHO HAS SKILLS AND KNOWLEDGE RELATED TO THE CONSTRUCTION AND OPERATION OF THE ELECTRICAL EQUIPMENT AND INSTALLATIONS AND HAS RECEIVED SAFETY TRAINING TO RECOGNIZE AND AVOID THE HAZARDS INVOLVED. (NEC 690.4(C), NEC 2020) • LOCAL UTILITY PROVIDER SHALL BE NOTIFIED PRIOR TO USE AND ACTIVATION OF ANY SOLAR PHOTOVOLTAIC INSTALLATION. FOR A LINE SIDE TAP CONNECTION, UTILITY NEEDS TO BE NOTIFIED WELL IN ADVANCE TO COORDINATE BUILDING ELECTRICAL SHUT OFF. • NEW CONDUIT ROUTING SHOWN IS ESSENTIALLY SCHEMATIC. SUBCONTRACTOR SHALL LAY OUT RUNS TO SUIT FIELD CONDITIONS AND THE COORDINATION REQUIREMENTS OF OTHER TRADES. • ARRAY WIRING SHOULD NOT BE READILY ACCESSIBLE EXCEPT TO QUALIFIED PERSONNEL. • ALL EXTERIOR CONDUIT, FITTINGS, AND BOXES SHALL BE WATERTIGHT AND APPROVED FOR USE IN WET LOCATIONS. (NEC 690), NEC 2020. • WIRING METHODS FOR PV SYSTEM CONDUCTORS AREN'T PERMITTED WITHIN 10 IN. OF THE ROOF DECKING OR SHEATHING EXCEPT WHERE LOCATED DIRECTLY BELOW THE ROOF SURFACE THAT'S COVERED BY PV MODULES AND ASSOCIATED EQUIPMENT WIRING • BACK -FED BREAKER MUST BE AT THE OPPOSITE END OF BUS BAR FROM THE MAIN BREAKER OR MAIN LUG SUPPLYING CURRENT FROM THE UTILITIES. • ALL CONDUCTORS AND WIRE TIES EXPOSED TO SUNLIGHT ARE LISTED AS UV RESISTANT. • CONTRACTOR SHALL FOLLOW ALL ELECTRICAL EQUIPMENT LABELING REQUIREMENTS IN NEC 690 • PV SOURCE, OUTPUT AND INVERTER CIRCUITS SHALL BE IDENTIFIED AT ALL POINTS OF TERMINATION, CONNECTION, AND SPLICES. THE MEANS OF ID CAN BE SEPARATE COLOR CODING, MARKING TAPE, TAGGING ETC. (NEC 690.4), NEC 2020. • MEASURE THE LINE -TO -LINE AND LINE -TO -NEUTRAL VOLTAGE OF ALL SERVICE ENTRANCE CONDUCTORS PRIOR TO INSTALLING ANY SOLAR EQUIPMENT. THE VOLTAGES FOR THE 208VAC RATED. N s 0 SHEET INDEX PV-0 PV-1 PV-2 PV-2A PV-3 PV-4 PV-5 PV-6 PV-7 to 13 COVER SHEET PLOT PLAN ROOF PLAN & MODULES BRANCH LAYOUT ATTACHMENT DETAIL ELECTRICAL LINE DIAGRAM WIRING CALCULATIONS WARNING LABELS & PLACARD EQUIPMENT SPECIFICATIONS 1 I COMMERCIAL BUILDING PHOTO PV-0 SCALE: NTS PROJECT SITE 'g8 Richland 6911 GALL BLVD., ZEPHYRMILLS, FL 33542 .000waft, (54) Zephyrhills LIJ)PHillsbor� Zephyrhills So�tti 2 I VICINITY MAP PV-0 Wildli SCALE: NTS TAM PA BAY Lj of,""4 rx POWERING THE SUNSHINE STATE 6002 E. ADAMO DR., TAMPA, FL,33619 PH. NO.: (813) 398-3687 Email : info@tampabaysolar.com REVISIONS DESCRIPTION DATE REV ELECTRICAL 01/15/2024 #1 CHANCES SETBACK 01/17/2024 #2 GIVEN CHANGED INVFRTFR TYPE 02/13/2024 #3 CALCULATION ADDED 02/15/2024 #4 SIGNATURE WITH SEAL DATE: 02/15/2024 PROJECT NAME &ADDRESS V Z N 0 � J _ �CY) Q M Q m CO� J J J J �_ _j w V Q w �� � w N 0 SHEET NAME COVER SHEET SHEET SIZE ANSI B 11 " X 17" SHEET NUMBER PV-0 SYSTEM SUMMARY 96 MISSION SOLAR MSE395SX9R (395W) MODULES 96 ENPHASE IQ8H-3P-72-E-US MICROINVERTERS SYSTEM SIZE:37.920 kW DC STC SYSTEM SIZE:36.48 kW AC STC RC (48) MISSION SOLAR MSE395SX9R (395W) MOt (E) MAIN SERVICE PANEL s 1 I PLOT PLAN PV-1 SCALE: 1 /25"=1'-0" 186 2" 0%^11 A e%t %r-jr%^ r% A T1 1I A / A \/ PROPERTY LINE NOTE ; VISIBLE, LABELED, LOCKABLE DISCONNECT LOCATED LESS THAN 10' FROM UTILITY METER NO ENCROACHMENT INTO EASEMENTS BY NEW SCOPE OF WORK (SOLAR PANELS, RACK/RAIL SYSTEMS & EQUIPMENT). #1 IISSION SOLAR MSE395SX9R � MODULES J J Q (E) DRIVEWAY TAM PA BAY :0 ""� SOLAR • POWERNG THE SUN%" STATE 6002 E. ADAMO DR., TAMPA, FL,33619 PH. NO.: (813) 398-3687 Email : info@tampabaysolar.com REVISIONS DESCRIPTION DATE REV ELECTRICAL 01/15/2024 #1 SETBA GIVEN 01/17/2024 #2 CHANGED 02/13/2024 #3 CALCULATION ADDED 02/15/2024 #4 SIGNATURE WITH SEAL DATE: 02/15/2024 PROJECT NAME &ADDRESS V ZL0 N " M J M Q m m L` _I J J WU �_ QW �a � N 0 SHEET NAME PLOT PLAN SHEET SIZE ANSI B 11" X 1711 SHEET NUMBER Pv-1 MODULE TYPE, DIMENSIONS & WEIGHT NUMBER OF MODULES = 96 MODULES MODULE TYPE = MISSION SOLAR MSE395SX9R (395W) MODULES MODULES MODULE WEIGHT = 48.5 LBS / 22 KG. MODULE DIMENSIONS = 75.08"x 41.5" = 21.63 SF UNIT WEIGHT OF ARRAY = 2.24 PSF SYSTEM SUMMARY 96 MISSION SOLAR MSE395SX9R (395W) MODULES 96 ENPHASE IQ8H-3P-72-E-US MICROINVERTERS SYSTEM SIZE: 37.920 kW DC STC SYSTEM SIZE: 36.48 kW AC STC W U z w w ry Q m LlJ Wl 1.1 s 4 ROOF #2 TILT - 200 AZIM. - 2700 (N) ENPHASE IQ8H-3P-72-E-US MICROINVERTERS ROOF #2 (48) MISSION SOLAR MSE395SX9R (395W) MODULES (N) LOAD CENTER (N) VISIBLE, LOCKABLE, LABELED AC DISCONNECT (E) UTILITY METER 1 I ROOF PLAN & MODULES PV-2 SCALE: 1/17"=V-0" NOTE ; VISIBLE, LABELED, LOCKABLE DISCONNECT LOCATED LESS THAN 10' FROM UTILITY METER NO ENCROACHMENT INTO EASEMENTS BY NEW SCOPE OF WORK (SOLAR PANELS, RACK/RAIL SYSTEMS & EQUIPMENT). W U z W W ry It 0 J J Q QD ROOF DESCRIPTION ROOF TYPE STANDING SEAM METAL ROOF ROOF AZIMUTH FRAMING FRAMING TILT SIZE SPACING #1 200 900 SEE STRUCTURAL LETTER #2 200 2700 ARRAY AREA & ROOF AREA CALC'S ROOF ARRAY ROOF AREA ROOF # OF AREA AREA COVERED MODULES (Sq. Ft.) (Sq. Ft.) BY ARRAY #1 48 1038.24 1133.44 92 #2 48 1038.24 1133.44 92 TOTAL ARRAY AREA WITH MOUNTING ROOF AREA TOTAL TOTAL ROOF TOTAL # ARRAY ROOF AREA ROOF OF AREA AREA COVERED MODULES (Sq. Ft.) (Sq. Ft.) BY ARRAY N #1 & #2 96 2076.48 4382.46 47 95SX9R (395W) MODULES D 'ILITY METER )LADECK kIN SERVICE PANEL ACD -VISIBLE, LOCKABLE, LABELED AC DISCONNECT 41.511 ,ok 00 O L6 MISSION SOLAR MSE395SX9R (395WW) MODULES ■-MICROINVERTERS - VENT, ATTIC FAN (ROOF OBSTRUCTION) l - ROOF ATTACHMENT - CONDUIT - LOAD CENTER ® - ZONE-2 ■ - ZONE-3 2W06 i 5 TAMPA BAY SOLAR • � PdWFRING Tl# SlI1V5FiN� SPATE 6002 E. ADAMO DR., TAMPA, FL,33619 PH. NO.: (813) 398-3687 Email : info@tampabaysolar.com REVISIONS DESCRIPTION DATE REV ELECTRICAL 01/15/2024 #1 SETBACK VEN 01 /17/2024 #2 CHANGED 02/13/2024 #3 CALCULATION ADDED 02/15/2024 #4 SIGNATURE WITH SEAL DATE: 02/15/2024 PROJECT NAME &ADDRESS V Z N qlqr u') cy) J M Q m m J J J wU �_ uj 0 SHEET NAME ROOF PLAN & MODULES SHEET SIZE ANSI B 11" X 1711 SHEET NUMBER PV-2 TALI PA BAY �i Pow�cT�susrA� 6002 E. ADAMO DR., TAMPA, FL,33619 PH. N0.: (813) 398-3687 Email :info@tampabaysolar.com SYSTEM SUMMARY �� NOTE_; 96 MISSION SOLAR MSE395SX9R (395W) MODULES 36 ACCESS PATHWAY VISIBLE, LABELED, LOCKABLE DISCONNECT LOCATED 96 ENPHASE IQ8H-3P-72-E-US MICROINVERTERS LESS THAN 10' FROM UTILITY METER SYSTEM SIZE:37.920 kW DC STC NO ENCROACHMENT INTO EASEMENTS BY NEW SCOPE OF SYSTEM SIZE:36.48 kW AC STC WORK (SOLAR PANELS, RACK/RAIL SYSTEMS & EQUIPMENT). CIRCUIT #2 T T SOLAR T � t T T CI CUIT #6 I i I I j T T 1 T � I 1 � T T � I I f uj SETBACK GIVEN IleT i U U w z j I ADDED i n w o + I + w 0 ♦ � UA i I I u __ --I oCD CIRCUIT #3 ,_1 _� t ; No 89MLL_ ; t t ,��•:rTAM CW 4ORIDP'� N� PROJECT NAME & ADDRESS CI RCUIT IT #7- C U/�llllll��� U I I CIRCUIT #8 u Q j .-- W uj cn V J �. �.... _ _J w O o� 0. co u) � J J Qm m� J J� - < �— Q— wv W a, _ Q CD � w N 0 U SHEET NAME N BRANCH LAYOUT w SHEET SIZE ANSI B s 11 " X 1711 SHEET NUMBER , „ PV-2A SCALE: 1/17 „_ -1 -0 BRANCH LAYOUT PV-2A CIRCUIT 1 CIRCUIT #4 CIRCUI #5CHANGES BILL OF MATERIALS EQUIPMENT QTY DESCRIPTION SOLAR PV MODULE 96 MISSION SOLAR MSE395SX9R (395W) MODULES MICRO -INVERTER 96 ENPHASE IQ8H-3P-72-E-US MICROINVERTERS LOAD CENTER 1 200A LOAD CENTER 3-PHASE, 4 WIRE, 208V/120V AC DISCONNECT 1 200A FUSED, (2) 130A FUSES, 3-PHASE, 208V/120V NEMA 3R, UL LISTED JUNCTION BOX 2 SOLADECKS 600 V, NEMA 3R UL LISTED RAILS 54 IRONRIDGE XR-100 RAILS 14' BLACK SPLICE KIT 48 BONDED SPLICE MODULE CLAMPS 180 UNIVERSAL MID CLAMP GROUNDING LUG 6 WEEB LUG W/ T-BOLT (96) MISSION SOLAR MSE395SX9R (395" MODULES MODULES (2) BRANCH f%lDt*%l ii--e nC I r, nnnni 11 CC Q (2) BRANCH 1 (4) BRANCH I SYSTEM S12 SYSTEM S12 BRANCH TERMINATOR (ET -TERM) BRANCH TERMINATOR (ET -TERM) BRANCH TERMINATOR (ET -TERM) BRANCH TERMINATOR (ET -TERM) BRANCH TERMINATOR (ET -TERM) BRANCH TERMINATOR (ET -TERM) BRANCH TERMINATOR (ET -TERM) BRANCH TERMINATOR (ET -TERM) ELECTRICAL LINE DIAGRAM SERVICE INFO �i Mr�ti/''%� No 89045 STATE OF • �Fs+S:c�ORIDPaG�2��� lzq ►ND L1 ►nlf.-o 5SX9R (395W) (In Inch) Tag # WIRE GAUGE # OF CONDUCTORS/COLOR *CONDUIT TYPE CONDUIT SIZE 1 PV WIRE #12AWG - 16 (8V+, 8V-) N/A -Free Air N/A -Free Air Bare Copper Ground (EGC/GEC) #8AWG - 1 BARE CU 2 PV-2 #10AWG - 16(8V+,8V-) B/R EMT 3/4 11 THWN-2 GND (EGC/GEC) #8AWG - 1 (GRN) 3 THWN-2 #1 AWG - 4 (1 L1, 1 L2, L3, 1 N) B/R/W PVC 1-1 /4 11 THWN-2 GND (GEC) #6AWG - 1 (GRN) 4 ITHWN-2 #1 AWG - 1 4 (1 L1, 1 L2, L3, 1 N) B/R/W PVC 1-1 /4" TAM PA BAY SOLAR �� annr�aucT�ssr►Ti= 6002 E. ADAMO DR., TAMPA, FL,33619 PH. NO.: (813) 398-3687 Email : info@tampabaysolar.com I REVISIONS I DESCRIPTION I DATE I REV 01/15/2024 1 #1 01/17/2024 1 #2 I(„.• CHANGED" 102/13/2024 1 #3 02/15/2024 1 #4 SIGNATURE WTH SEAL DATE: 02/15/2024 PROJECT NAME &ADDRESS V Z N qq" 0 L0 J " M M > j Q m Co �`' J J J < j W 0 Q w o, _ � CD a. N 0 U SHEET NAME ELECTRICAL LINE DIAGRAM SHEET SIZE ANSI B 11" X 1711 SHEET NUMBER PV-4 im SCALE: NTS MAX PV VOLTAGE & CURRENT CALC'S: BRANCH CIRCUIT MAX VOLTAGE: 208.OVAC MAX PV CURRENT PER NEC.690.8(A)(3) 1.25X MAX AC OUTPUT CURRENT X # OF INVERTERS PER STRING 1.25 X 1.83 X 15 = 34.31A 1.25 X 1.83 X 13 = 29.73A 1.25 X 1.83 X 10 = 22.87A AC CONDUCTOR AMPACITY CALCULATIONS: FROM ROOF TOP JUNCTION BOX TO LOAD CENTER: AMBIENT TEMPERATURE ADJUSTMENT FOR EXPOSED CONDUIT PER NEC 310.15(B)(2)(C): -10° EXPECTED WIRE TEMP (*C): 30° TEMP CORRECTION PER TABLE 310.16: 1 # OF CURRENT CARRYING CONDUCTORS: 16 CONDUIT FILL CORRECTION PER NEC.310.15(13)(2)(a): 0.5 CIRCUIT CONDUCTOR SIZE: 10AWG CIRCUIT CONDUCTOR AMPACITY: 40A REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC.690.8(A&B): 1.25 X MAX AC OUTPUT CURRENT X # OF INVERTERS PER STRING 1.25X1.83X15=34.31A 1.25 X 1.83 X 13 = 29.73A 1.25 X 1.83 X 10 = 22.87A DERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC TABLE 310.16 TEMP CORR. PER NEC TABLE 310.16X CONDUIT FILL CORR. PER NEC 310.15(B)(2)(a) XCIRCUIT CONDUCTOR AMPACITY = 1 X0.5X40=20A AC CONDUCTOR AMPACITY CALCULATIONS: FROM LOAD CENTER TO MSP: EXPECTED WIRE TEMP ('C): 30° TEMP CORRECTION PER TABLE 310.16: 1 CIRCUIT CONDUCTOR SIZE: 1 AWG CIRCUIT CONDUCTOR AMPACITY: 145A # OF CURRENT CARRYING CONDUCTOR: 3 CONDUIT FILL PER NEC 310.15(B)(2)(a): 1 OUTPUT CURRENT OF INVERTER X TOTAL NUMBER OF INVERTERS 1.25 X 1.83 X 96 = 219.60A DERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC TABLE 310.16 TEMP CORR. PER NEC TABLE 310.16 X CONDUIT FILL CORR. PER NEC 310.15(B)(2)(a) XCIRCUIT CONDUCTOR AMPACITY = 1 X 1 X 145 = 145A INTERNAL VOLTAGE RISE WITHIN THE ENGAGE CABLES: PER ENPHASE TABLE: BRANCH CIRCUIT OF 15 = 1.38% BRANCH CIRCUIT OF 13 = 1.06% BRANCH CIRCUIT OF 10 = 0.65% VOLTAGE RISE FROM THE ARRAY MOUNTED JUNCTION BOX TO LOAD CENTER: VRISE _ (AMPS/INVERTER * #OF INVERTER)* (RESISTANCE Q/FT) * (2 WAY WIRE LENGTH VRise = (1.83A*15) * (0.001290/ft)�2* (20ft X 2) VRise = 1.416V VRise = 1.416V/208V = 0.59% Vrise VOLTAGE RISE FROM LOAD CENTER TO MAIN SERVICE PANEL: Vrise = (SUM OF STRING CURRENT) * (RESISTANCE f2/FT) * (2 WAY WIRE LENGTH) VRise = (1.83 X96) * (0. 000 1 600/FT) * (20 X 2) VRise = 1.124 VRise = 1.124V/208V = 0.47% SUMMARY OF CALCULATIONS FOR 208VAC APPLICATIONS: 1.38 + 0.59 + 0.47 = 2.44% 2.44%<2%=OK -t s a NYr�S►��� * No 89045 STATE OF AL ������ III%I\ � VOLTAGE RISE FROM THE ARRAY MOUNTED JUNCTION BOX TO LOAD CENTER: VRISE _ (AMPS/INVERTER * #OF INVERTER)* (RESISTANCE.Q/FT) * (2 WAY WIRE LENGTH VRise = (1. 83A* 13) * (0. 00 1 290/ft) * (20ft X 2) VRise=1.227V VRise = 1.227V/208V = 0.511 % Vrise VOLTAGE RISE FROM LOAD CENTER TO MAIN SERVICE PANEL: Vrise = (SUM OF STRING CURRENT)'` (RESISTANCE Q/FT) * (2 WAY WIRE LENGTH) VRise = (1.83 X96) * (0.0001600/FT) * (20 X 2) VRise = 1.124 VRise = 1.124V/208V = 0.47% SUMMARY OF CALCULATIONS FOR 208VAC APPLICATIONS: 1.06+0.511 +0.47=2.0% 2.0%<2%=OK TAMPA BAY . " R • i POWU*C THESlNVSFI STATE 6002 E. ADAMO DR., TAMPA, FL,33619 PH. NO.: (813) 398-3687 Email : info@tampabaysolar.com REVISIONS DESCRIPTION DATE REV 01/15/2024 #1 SETBACK GIVEN 01/17/2024 #2 CHANGED 02/13/2024 #3 CALCULATION ADDED 02/15/2024 #4 ------------ SIGNATURE WITH SEAL DATE: 02/15/2024 PROJECT NAME &ADDRESS V Z N 0 Mt Lo "M J0 M LL Q m m J � J _j WU Q � �a � N 0 I SHEET NAME WARNING LABELS & PLACARDS SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-5 VOLTAGE RISE FROM THE ARRAY MOUNTED JUNCTION BOX TO LOAD CENTER: VRISE _ (AMPS/INVERTER * #OF INVERTER)* (RESISTANCE Q/FT) * (2 WAY WIRE LENGTH VRise = (1. 83A* 10) " (0. 00 1 290/ft) * (20ft X 2) VRise = 0.944V VRise = 0.944V/208V = 0.39% Vrise VOLTAGE RISE FROM LOAD CENTER TO MAIN SERVICE PANEL: Vrise = (SUM OF STRING CURRENT) * (RESISTANCE Q/FT) * (2 WAY WIRE LENGTH) VRise = (1.83 X96) * (0.0001600/FT) * (20 X 2) VRise = 1.124 VRise = 1.124V/208V = 0.47% SUMMARY OF CALCULATIONS FOR 208VAC APPLICATIONS: 0.65 + 0.39 + 0.47 = 1.51% 1.51%<2%=OK tT No 89045 V 131. STATE OF : w O • � • . � �� 3/► J2Y TAMPA BAY SOLAR • � POVVE�NG'niE SUNSFA� STATE 6002 E. ADAMO DR., TAMPA, FL,33619 PH. NO.: (813) 398-3687 Email : info@tampabaysolar.com REVISIONS DESCRIPTION DATE REV ELECTRICAL 01/15/2024 #1 SETBACK GIVLN 01/17/2024 #2 CHANGED 02/13/2024 #3 CALCULATION ADDED 02/15/2024 #4 SIGNATURE WITH SEAL DATE: 02/15/2024 PROJECT NAME &ADDRESS V ZLO N J "M M > -j Q m m L` � J J J WU �_ Qw �_ � a N 0 SHEET NAME WARNING LABELSI & PLACARDS I SHEET SIZE ANSI B 11" X 1711 SHEET NUMBER PV-5A SIGNAGE REQUIREMENTS: RED BACKGROUND WHITE LETTERING MINIMUM 3/8" LETTER HEIGHT ALL CAPITAL LETTERS ARIAL OR SIMILAR FONT REFLECTIVE WEATHER RESISTANT MATERIAL, UL969 AWARNIN ELECTRIC SHOCK HAZARD TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION PV WIRE �F MICRO INVERTER SOLAR ARRAY WARNINGDUAL POWER SOURCE 1, A ECOND SOURCE IS PHOTOVOLTAIC E j SYSTEM AD LABEL LOCATION: LABEL LOCATION: AC & DC DISCONNECT AND SUB PANEL (PER CODE: NEC 690.17(E) AWARNING ELECTRIC SHOCK HAZARD TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION DC VOLTAGE IS ALWAYS PRESENT WHEN SOLAR MODULES ARE EXPOSED TO SUNLIGHT LABEL LOCATION: DC DISCONNECT, POINT OF INTERCONNECTION (PER CODE: NEC 690.17(E) LABEL LOCATION: (PER CODE: NEC 690.5(C) NEC 690.54 MAIN SERVICE PANEL &NET METER (PER CODE: NEC 705.12(G)(3), NEC 705.12(B)(3-4) &NEC 690.59) A WARNING THE DISCONNECTION OF THE GROUNDED CONDUCTOR(S) MAY RESULT IN OVERVOLTAGE ON THE EQUIPMENT LABEL LOCATION: INVERTER (PER CODE: NEC 690.31(I) LABEL LOCATION: RAPID SHUTDOWN (PER CODE: NEC 690.56(C)(3) CFi LABEL LOCATION: MAIN SERVICE DISCONNECT / UTILITY METER (PER CODE: NEC 690.13(B)) JUNCTION BOX 0 s I lei I to] TLA Is LABEL LOCATION: NEC 690.13(B) LOAD CENTER �A F B - - H C N LABEL LOCATION: SERVICE PANEL IF SUM OF BREAKERS EXCEEDS PANEL RATING (PER CODE: NEC 705.12 (13)(2)(b) SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION SOPV pANELSRIC TO SHUTDOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN ARRAY LABEL LOCATION: (PER CODE: 605.11.3.1(1) & 690.56(C)(1)(a)) �� AC DISCONNECT METER MAIN SERVICE PANEL RC e ry � No 89045 r STATE OF 4u zz I111111 �� CAUTION: MULTIPLE SOURCES OF POWER POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN AT: MAIN SERVICE PANEL & UTILITY METER AC DISCONNECT LOAD CENTER 6911 GALL BLVD.,ZEPHYRHILLS, FL 33542 (E) MAIN SERVICE PANEL-3 (E) MAIN SERVICE PANEL-2 (E) MAIN SERVICE PANEL-1 (N) LOAD CENTER (N) VISIBLE, LOCKABLE, LABELED AC DISCONNECT (E) UTILITY METER PER CODE(S): NEC 2020 : 710.10 H TAMPA BAY .' SOLAR" •0 POWERING THE SI N ISHK STATE 6002 E. ADAMO DR., TAMPA, FL,33619 PH. NO.: (813) 398-3687 Email : info@tampabaysolar.com REVISIONS DESCRIPTION DATE REV ELECTRICAL 01/15/2024 #1 CHANGES SETBACK 01/17/2024 #2 GIVEN CHANGED LVFRTFR TYPE 02/13/2024 #3 CALCULATIONADD LD 02/15/2024 #4 SIGNATURE WITH SEAL DATE: 02/15/2024 PROJECT NAME &ADDRESS V Z N 0 � � _ Q co co Q m m Li- J J �J w U2i 2 a- 73 N 0 U SHEET NAME WARNING LABS! S� & PLACARDS SHEET SIZE ANSI B 11" X 1711 SHEET NUMBER PV-6 bp 7 706