HomeMy WebLinkAbout7333 Gall Blvd (3)11 11 _11 I I III I_ 1 11 1 - I GENERAL K 1 r- r_% 81 PROJECT NOTES C)ENERAL I 1\4 GENERAL NOTES: 1 INTERPRETATION, ERRORS AND OMISSIONS: SHOULD ANY OMISSION, DISCREPANCY, AMBIGUITY OR ERROR IN THE CONTRACT DOCUMENT DRAWINGS BE DISCOVERED OR SHOULD THERE BE ANY DOUBT AS TO THE MEANING OR INTENT THEREOF, REPORT SUCH FINDINGS TO THE ARCHITECT IN WRITING. WITHIN A REASONABLE TIME OF RECOVERY IF buklN6 THE— CURSE OF CONSTRUCTION, CONFLICTS ARE FOUND IN THE DRAWINGS OR EXISTING SITE CONDITIONS, THE ARCHITECT WILL INTERPRET OR CONSTRUE THE DRAWING(S) AND / OR EXISTING SITE CONDITIONS SO AS TO SECURE THE MOST SUBSTANTIAL AND COMPLETE PERFORMANCE OF THE WORK. 2. DIMENSIONS ON PLANS ARE TO FINISH FACE OF WOODIMETAL STUD PARTITIONS AND FACE OF CONCRETE MASONRY UNIT WALLS UNLESS NOTED OTHERWISE. 3. THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS PRIOR TO BEGINNING DEMOLITION AND/OR CONSTRUCTION- ANY DISCREPANCIES BETWEEN ACTUAL CONDITIONS AND THOSE REPRESENTED IN THE CONSTRUCTION DOCUMENTS SHALL BE BROUGHT TO THE ARCHITEcrs ATTENTION IMMEDIATELY. 4. THE CONTRACTOR SHALL VERIFY THE LOCATION OF ALL EXISTING UTILITIES PRIOR TO CONSTRUCTION SHOULD THE ASSISTANCE OF THE OWNER, ARCHITECT OR ENGINEER BE REQUIRED THE CONTRACTOR SHALL ALLOW FOR THE REQUIRED NOTIFICATION PERIOD IN THE CONSTRUCTION SCHEDULE- 5. STUD THICKNESS SHALL BE INCREASED AS REQUIRED AT PLUMBING HANGERS, ELECTRICAL PANELS, ETC., WHICH EXCEED 4° FROM FINISH WALL FACE TO BACK OF UNIT. 6. FURNISH ACCESS PANELS IN WALLS AND NON -ACCESSIBLE TYPE CEILINGS WHERE SERVICE OR ADJUSTMENT 70 MECHANICAL, PLUMBING OR ELECTRICAL EQUIPMENT IS REQUIRED. (SEE ENGINEERING DRAWINGS FOR ANY REQUIRED ACCESS PANEL(S) FOR THIS PROJECT) 7. PROVIDE CONTROL JOINTS IN GYPSUM WALLBOARD AT 30 FEET O.C. MAXIMUM PER MANUFACTURER'S RECOMMENDATION. WHERE POSSIBLE, LOCATE JOINTS ABOVE DOOR FRAMES. 8, GYPSUM WALLBOARD IN TOILETS, AND OTHER AREAS SUBJECT TO WETTING, SHALL BE MOISTURE RESISTANT TYPE GIN WALLS- ON WALLS TO RECEIVE CERAMIC TILE, FINISH GYPSUM WALLBOARD SHALL BE MOISTURE RESISTANT TYPE. 9, ALL GYPSUM WALLBOARD IN FIRE RATED WALLS SHALL BE FIRE RESISTANT UL CLASSIFIED MATERIAL APPLIED IN STRICT CONFORMANCE TO THE APPLICABLE FIRE TEST DESIGN WITH JOINTS ON OPPOSITE WALL FACES STAGGERED. FASTENERS SHALL BE OF APPROVED TYPE AND INSTALLED IN ACCORDANCE WITH APPLICABLE FIRE TEST. ALL WALLBOARD JOINTS SHALL BE TAPED AND FINISHED WITH JOINT COMPOUND, INCLUDING THOSE ABOVE CEILING, WHETHER FIRE RATED OR NOT PENETRATION FOR PIPES, CONDUIT, DUCTS, ETC. IN EXCESS OF 8' IN MAXIMUM DIMENSION SHALL BE FRAMED. PERIMETER OF PENETRATIONS SHALL BE TIGHTLY PACKED WITH MINERAL FIBER SAFING INSULATION. w CONTRACTOR SHALL VERIFY AND COORDINATE SPECIFIC REQUIREMENTS FOR OWNER -PROVIDED AND/OR INSTALLED EQUIPMENT- 11. ALL OTHER MAJOR TENANTS AND SHOP CONSTRUCTION IS DESCRIBED WITHIN SEPARATE WORKING DRAWINGS, 12. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING ALL WORK INCLUDED IN THE CONTRACT DOCUMENTS. ALL CORRESPONDENCE FROM SUBCONTRACTORS SHALL BE ROUTED THROUGH THE GENERAL CONTRACTOR 13 ADJACENT WORK, INCLUDED UNDER OTHER CONSTRUCTION CONTRACTS, WHICH IS DAMAMGED DURING EXECUTION OF THIS CONTRACT WORK, SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO REPAIR PRIOR TO FINAL ACCEPTANCE OF THE WORK 14 GENERAL CONTRACTOR SHALL REPLY WITH ALL REQUIREMENTS OF CURRENT SOILS REPORT. 15 GENERAL CONTRACTOR TO PROVIDE ALL GOVERNMENT -REQUIRED SIGNAGE NECESSARY FOR CERTIFICATE OF OCCUPANCY (FIRE LANE 5IGNAGE, 'DO NOT BLOCK DOOR-, ETC.) W ALL FIRE RATED CONSTRUCTION SHALL CONFORM WITH U.L. TESTED STANDARDS ANDIOR LOCAL REQUIREMD4TS_ 17. CONTRACTOR TO INCLUDE IN BID, ALL MISCELLANEOUS MATERIAL REQUIRED FOR A COMPLETE INSTALLATION PER THE DESIGN INTENT AS DEFINED BY THE CONTRACT DOCUMENTS. MISCELLANEOUSMATERIAL INCLUDES, BUT IS NOT LIMITED TO FASTENERS, HANGERS, FURRING STRIPS, BLOCKING, TRIM AND OTHER MATERIALS NOT SPECIFICALLY INDICATED ED BUT REQUIRED FOR A COMPLETE INSTALLATION. SITEWORK NOTES. I. FOUNDATIONS HAVE BEEN DESIGNED FOR ALLOWABLE SOIL BEARING AS NOTED ON STRUCTURAL DRAWINGS- THR GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING INSPECTION OF SOIL CONDITIONS AFTER EXCAVATION WITH OWNER',$ TESTING SERVICE TO DETERMINE IF BEARING CAPACITY IS SUFFICIENT AND MAINTAINING EXCAVATION IN SUCH AS A WAY THAT THE BEARING CAPACITY IS MAINTAINED UNTIL PLACEMENT OF FOOTING. 2. OVER -EXCAVATION OF FOUNDATIONS SHALL BE FILLED ONLY AS DIRECTED BY THE STRUCTURAL ENGINEER. 3. ALL CIVIL WORK IS DEFINED UNDER SEPARATE CIVIL DOCUMENTATION PROVIDED BY THE CIVIL ENGINEER. 4. UNLESS NOTED OTHERWISE, PROVIDE 18'x 24'CONCRITE SPLASH BLOCKS AT ALL DOWNSPOUTS WHERE DOWNSPOUTS SPILL ONTO ASPHALT PAVING 5, REFER TO CIVIL DRAWING FOR PAVING THICKNESS, CURB TYPES, LONGITUDINAL AND AND HORIZONTAL CONTROL. FOR BUILDING LOCATION SETBACKS REFER TO CIVIL DRAWINGS- 6. REFER TO LANDSCAPE DRAWINGS FOR LANDSCAPE REQUIREMENTS - (N-1 C) 7. COORDINATE WATER (DOMESTIC AND FIRELINE) AND GAS METER LOCATIONS WITH CIVIL ENGINEER- FIELD VERIFY ALL LOCATIONS. 8. FIELD COORDINATE TRANSFORMER PAD LOCATIONS WITH ELECTRICAL ENGINEER REFER TO ELECTRICAL & CIVIL DRAWINGS FOR GENERAL INFORMATION 9. REFER TO A100 FOR SIDEWALK REQUIREMENTS 10, THE CONTRACTORS AND SUBCONTRACTORS SHALL COORDINATE THE WORK AND PHASING OF WORK DESCRIBED HEREIN WITH THE CIVIL ENG NEERING AND LANDSCAPE PLANS ISSUED SEPARATELY BY: CIVIL; CDG ENGINEERS& ASSOCIATES, INC. LANDSCAPE: N I.C. 11 CONNECTIONS TO UNDERGROUND UTILITY LINES AT 6 OUTSIDE THE BUILDING SHALL BE MADE BY THE BUILDING CONTRACTOR. CONTRACTOR TO PROVIDE SECONDARY RADEWAY AND CONDUCTOR FROM THE TRANSFORMER TO THE PANEL AT EACH BUILDING PANEL AND LANDLORD PANEL- COORDINATE WITH CIVIL UTILI TY DRAWINGS. FIELD COORDINATE AS NECESSARY. CONCRETENOTES: 1. DESIGN LOADS AREAS SPECIFIED BY THE STRUCTURAL DRAWINGS, MASONRY NOTES: 1. ALL MASONRY VENEER SHALL BE 100% SOLID MATERIAL AT CORBEL AND/OR REVEAL TRIM WORK PRESENT ALTERNATE SOLUTION(S) TO ARCHITECT FOR APPROVAL. WOOD NOTES: 1. CONTRACTOR SHALL BE RESPONSIBLE FOR DETERMINING AND PROVIDING REQUIRED BLOCKING FOR ALL WALL MOUNTED EQUIPMENT AND FIXTURES FIELD COORDINATE. THERMAL & MOISTURE PROTECTION NOTES:. 1 . ALL FLASHING DETAILS ARE TO BE IN ACCORDANCE WITH SMACNA "ARCHITECTURAL. SHEET METAL MANUAL', MOST CURRENT EDITION PRESENT PROPOSED ALTERNATE TO ARCHITECT FOR APPROVAL- 2 ALL GUTTERS, DOWNSPOUTS, GRAVEL STOPS, FASCIAS, FLASHING, LOUVERS, SCREENS, METAL STRUCTURES AND ANY ROOF PENETRATIONS ARE TO BE INSTALLED AND FABRICATED AS PER SMACNA STANDARDS OR IN ACCORDANCE WITH ROOFING MANUFACTURE'S RECOMMENDATIONS AS REQUIRED TO OBTAIN MANUFACTURE'S WARRANTIES REOUIRED BY THE SPECIFICATIONS. PRESENT PROPOSED ALTERNATE(S) TO ARCHITECT FOR APPROVAL. 3. R-RATINGS FOR ASSEMBLIES ARE TO MEET OR EXCEED THE ENERGY EFFICIENCY REQUIREMENTS OF THE CURRENT ENERGY CODE OR TENANT REQUIREMENT, WHICHEVER IS GREATER. 4. CONTRACTOR SHALL PROVIDE FLASHING FOR ALL WINDOWS, STOREFRONT AND DOOR JAMBS, SILLS & HEADS, SUBMIT SHOP DRAWINGS FOR ARCHITECT'S APPROVAL PRIOR TO START OF CONSTRUCTION. 5 CAULK THE INTERIOR PERIMET ER AND SEAL THE EXTERIOR PERIMETER OF ALL DOORS. STOREFRONTS AND WINDOWS WITH APPROVED CAULKING AND SEALANT REFER TO SPECIFICATIONS FOR ACCEPTABLE MATERIALS 6 ALL EXTERIOR DOORS ARE TO BE WEATHERSTRIPPED WITH THRESHOLDS SET IN CAULKING BED. PROVIDE RAIN GUARDS AT HEAD AS REQUIRED- SUBMIT SAMPLES TO ARCHITECT FOR APPROVAL PRIOR TO BEGINNING THE WORK 7. GENERAL CONTRACTOR IS TO PROVIDE A THERMAL BARRIER BETWEEN THE ROOF DECK AND THE INSULATION. APPROPRIATE THERMAL BARRIER IS DICTATED IN THE FOAM PLASTICS INSULATION SECTION OF THE CURRENT BUILDING CODE, THERMAL BARRIER MAY BE OMITTED ONLY IF THE CONTRACTOR CAN PROVIDE TEST DATA WHICH STATES THAT THE INSULATION INTENDED FOR USE ON THIS PROJECT PASSES UL 1256 AND/OR FM 4450- GENERAL CONTRACTOR TO PROVIDE SILL FLASHING BY WINDOW WALL MANUFACTURER. FLASHING IS A REQUIRED INTEGRAL PART OF THE SPECIFIED WINDOW WALL SYSTEM. P, - GENERAL CONTRACTOR TO PROVIDE BITUMINOUS DAMPROOFING OVER ALL C.M.U. WHERE ARCHITECTURAL VENEER OR BRICK VENEER OCCURS. 0- GENERAL CONTRACTOPTO PROVIDE BITUMINOUS MEMBRANE WATER PROOFING AT ALL AREAS WHERE INTERIOR FINISH GRADE IS BELOW EXTERIOR FINISH GRADE. SEAL ALL PENETRATIONS AT EXTERIOR WALLS TO INSURE WEATHER TIGHTNESS. DOORNOTES I . HOLLOW METAL DOOR FRAMES LOCATED IN EXTERIOR BLOCK WALLS SHALL BE FILLED WITH GROUT. 2. EXTERIOR AND INTERIOR PASSAGE DOORS WHERE OPERABLE HARDWARE IS PROVIDED SHALL BE EQUIPPED WITH HANDLES, PULLS, LATCHES, LOCKS AND OTHER OPERATING HARDWARE DEVICES HAVING A SHAPE THAT IS EASY TO GRASP WITH ONE HAND AND DOES NOT REQUIRE TIGHT GRASPING, TIGHT PINCHING OR ANY WRIST -TWISTING MOTION TO OPERATE. 3. TO AID BLIND, VISUALLY IMPAIRED PERSONS OR PERSONS WITH LOW VISION CAPABILITIES, DOORS LEADING TO LOADING DOCKS OR PLATFORMS, BOILER ROOMS, STAGES, ELECTRICAL EQUIPMENT ROOMS, ETC- SHALL BE MADE READILY IDENTIFIABLE TO THE TOUGH BY A TEXTURED SURFACE ON THE DOOR HANDLE, KNOB, PULL OR OTHER OPERATING HARDWARE. PROVIDE ALL REQUIRED ADA COMPLIANT SIGNAGE AT AREAS LISTED ABOVE. FINISH NOTES: I. CLEAN AND PRIME ALL SURFACES PRIOR TO PAINTING IN ACCORDANCE WITH PAINTING MANUFACTURER'S RECOMMENDATIONS. PAINT ALL SIX SURFACES OF DOORS AS WELL 2. METAL ACCESS PANELS AND ELECTRICAL PANEL LOUVERS SHALL NOT BE PAINTED WITH LATEX PAINT. PAINT PANELS WITH OIL BASED GLOSS ENAMELS MATCHING MANUFACTURER'S RECOMMENDATIONS- 3, METAL STUD GAUGES (SEE DRAWINGS) AND BRACING REQUIREMENTS FOR INTERIOR PARTITIONS SHALL BE AS RECOMMENDED AND/OR REQUIRED BY THE STUD MANUFACTURER (AND ALL APPLICABLE CODES) FOR EACH SPECIFIC CONDITION UNLESS OTHERWISE NOTED. 4. PROVIDE DRAFT STOPPING IN CANOPIES AT INTERVALS NOT TO EXCEED 3,0o0 SF 9 HORIZ. AREA) AND WHERE SPECIFICALLY CALLED FOR ON DRAWINGS DRAFT STOPPING HALL BE V2" GYP. RD. ON ONE SIDE OF LIGHT GAUGE METAL FRAMING. PLUMBING NOTES: I TOILETS SHALL BE HANDICAP ACCESSIBLE AS REQUIRED BY APPLICABLE LAWS. CODES AND STATUTES- REFER TO TI DRAWINGS FOR EACH TENANT. Z THE ENTIRE STRUCTURE SHALL BE SPRINKLERED (WHEN REQUIRED) IN ACCORDANCE WITH TENANT SPECIFIC REQUIREMENTS AND WITH APPLICABLE CODES. FIRE DEPT NOTES: 1. EVERY BUILDING HEREAFTER CONSTRUCTED SHALL BE ACCESSIBLE TO FIRE DEPARTMENT APPARATUS BY WAY OF ACCESS ROADWAYS WITH ALL-WEATHER DRIVING SURFACE OF NOT LESS THAN 20 FT. OF UNOBSTRUCTED WIDTH, WITH ADEQUATE ROADWAY TURNING RADIUS CAPABLE OF SUPPORTING THE IMPOSED LOADS OF FIRE APPARATUS AND HAVING A MINIMUM VERTICAL CLEARANCE OF 13 FT. 6 IN, 2. WHERE EXIT LIGHTS, SIGNS OR THE EXITS THEMSELVES ARE NOT VISIBLE FROM THE EXIT APPROACH, DIRECTIONAL SIGNS INDICATING THE WAY OF EGRESS SHALL BE PROVIDED. COORDINATE LEVEL OF SIGNAGE WITH CIVIL DRAWINGS 3 AS REQUIRED, SEPARATE OR EMERGENCY SOURCE OF ILLUMINATION SHALL BE PROVIDED IN THE FOLLOWING OCCUPANCIES: a) WINDOWLESS BUILDINGS b) INTERIOR EGRESS CORRIDORS WITH NO NATURAL ILLUMINATION c) OCCUPANT CAPACITIES EXCEEDING 150 PERSONS, APPLICABLE CODE 5th ADDITION FLORIDA BUILDING CODE 2014 5th ADDITION FLORIDA PLUMBING CODE 2014 5th ADDITION FLORIDA MECHANICAL CODE 2014 ELECTRICAL CODE :2011 NATIONAL ELECTRICAL CODE 5th ADDITION FLORIDA EXISTING BUILDING CODE 2014 5th ADDITION FLORIDA ENERGY CONSERVATION CODE 2014 5th ADDITION FLORIDA FUEL GAS CODE 2014 BUILDING INFORMATION. TOTAL LEASED AREA 1,620 SQ. FT. TOTAL RETAIL AREA 803 SQ. FT. USE GROUP: M IBC SECTION 303.1 CONSTRUCTION TYPE: 2-B, PROTECTED IBC SECTION 602.5 ALLOWABLE AREA: 6,000 SQ. FT. IBC TABLE 503 ACTUAL AREA: 1,620 SQ. FT. FIRE PROTECTION: NOT REQUIRED, NOT PROVIDED IBC SECTION 903.2,1.2 FIRE ALARM: NOT REQUIRED, NOT PROVIDED IBC SECTION 907.2.1 OCCUPANCY: IBC TABLE 1004.1.1 AREA SQ. FT. SF/OCC OCC. LOAD SALES FLOOR 803 60 14 STORAGE/B.O.H. 817 300 3....... 17 EGRESS: REQ'D PROVIDED EGRESSWIDTH- DOORS 82 x 0.2" = 16.4" 114'' IBC SECTION 1005 NUMBER OF EXITS: 2 2 IBC SECTION 1015 EXIT ACCESS TRAVEL DIST. 'M'USE = 200'-0" IBC TABLE 1016.1 COMMON PATH OF TRAVEL 'M'USE = 75'-0" IBC SECTION 1014.3 PLUMBING FIXTURES: IBC TABLE 2902.1 FIXTURE RATIO (M/F) REQ'D PROVIDED WC 1:500/1:500 1/1 1/1 UR --- 0 1 LAV 1:750 1/1 1/1 0 EMobile 0 AT GALL BLVD & DAUGHTERY RD SAP # 511 D 7333 GALL BLVD, SUITE #7335 ZEPHYRHILLS, FL 33541 VICINITY MAP NOTES SALES FLOOR - SEE DESIGN DRAWINGS FOR SPECIFICS 0 NETWORKING (ONLY HALF OF THE REQUIRED RUNS) 0 FAX LINE RAN TO SC PRT FROM NETWORK WALL 0 ELECTRICAL EXACTLY AS INDICATED 0 LIGHTING EXACTLY AS INDICATED 0 CEILING GRID AND TILES AS INDICATED 0 FIXTURES TO BE INSTALLED BY GC OR TRIAD WILL DISCUSS) 0 FLOORING EXACTLY AS INDICATED (TO BE ORDERED BY GP MOBILE, - GC TO PROVIDE REQUIRED QUANTITIES AND REQUESTED DELIVERY DATE) 0 FINISHES EXACTLY AS INDICATED BACK OF HOUSE - REMOVE / BUILD WALLS AS NEEDED - COMMERCIAL GRADE VINYL FLOORING (IF NEEDED) - DUPLEX RECEPTACLE ON EACH WALL IN EVERY ROOM AND HALLWAY I X DUPLEX RJ45 JACK (CAT5E CABLE) IN EACH ROOM -WALL PAINT (SAME AS SALES FLOOR) -VINYL BASEBOARDS - FLUORESCENT LIGHT FIXTURES (IF NEEDED) - STEEL EXIT DOOR SECURITY BARS INSTALLED ON OUTSIDE BACK DOOR (LIKE THIS ONE HTTPS-/NVNW.DOORWARE.COM/SITE/PRODUCT.CFM?ID=181024) - ALL INSIDE DOORS AND FRAMES PAINTED WHITE (GLOSSY PAINT) NETWORKING - NETWORK WALL (4'X 4- PLYWOOD MOUNTED ON WALL NEAR ELECTRICAL PANEL) - 2 X FOURPLEX RECEPTACLES INSTALLED ON NETWORK WALL - SU WALL MOUNTED OPEN RACK INSTALLED ON NETWORK WALL 0 INSTALL NETGEAR PROSAFE JGS524NA 24-PORT GIGABIT RACKMOUNT SWITCH 10/100/1000 MBPS (JGS524NA) MOUNTED IN THE RACK 0 ETHERNET PATCH PANEL MOUNTED IN THE RACK - CAMERA SYSTEM 0 INSTALL 8 CAMERAS (PROVIDED BY GP MOBILE) 0 RUN BNC W/ POWER CABLES FROM CAMERA TO NETWORK WALL (PROVIDED BY GP MOBILE) TURNOVER - PERFORM SERVICE ON HVAC SYSTEM 0 CLEANING 0 FILTERS 0 CHANGE THERMOSTAT(S) (PROVIDED BY GP MOBILE) - CLEAN STORE 0 WASH FLOORS 0 CLEAN FIXTURES 0 CLEAN RESTROOMS 0 CLEAN WINDOWS ADDITIONAL CONTRACTORS (THAT WILL BE ON SITE DURING PROJECT) -ALARM SYSTEM (ADT OR PRECISION 1) - ROLL DOWN GATES (QMI) - INVENTORY SAFE (BLUE DOT) - SIGNS (MC SIGNS) - SHOPPER TRAK (SHOPPER I RAK) - INTERNET SERVICE PROVIDER KEY PLAN ADDRESS -. 7333 GALL BLVD QITEo73f; I ZEPHYRHILLS, FL.' PROJECT LOCATION PROJECT TEAM PROJECT OWNER I ARCHITECT Company: XXX Company: XXX Address : XXX Address : XXX City, State Zip XXXX City, State Zip XXXX P: XXX P: XXX F: F: Contact: XXX Contact: XXX STRUCTURAL CONTRACTOR pany: XXX Company: T.B.D. Addres xxx Address: XXX City, ity, State Zi xxx City, State Zip XXXX P: XXX P: XXX F: F Contact: XX Contact: XXX ALL WORK SHALL COMPLY WITH PREVAILING CODES IORIDA BUILDING CODE, I%ATIONAL ELEC-RIC CODE, AND CITY OF ZEPHYRHILLS ORIDINANC98 MEP I CIVIL ENGINEER Company: XXX \COM a Address: XXX dd r e�s , n YX" XXX XXX City, State Zip XXXX CiNState Zip XXXX P: XXX P: F: F: Contact: XXX Contact: N3NIVYVX3 INIVId qAHcl3Z �o Ailo � DRAWING INDEX A100 COVER SHEET Al 01 FIXTURE PLAN Alli FINISH PLAN All 21 REFLECTED CEILING PLAN A201 INTERIOR ELEVATIONS A501 DETAILS A601 SCHEDULES El 01 ELECTRICAL GUIDELINES PLAN E501 FIXTURE FEED WIRING DETAILS E511 FIXTURE FEED WIRING DETAILS E512 LIGHTING PLAN r_7 GC SCOPE OF WORK: SCOPE OF WORK INCLUDES THE FOLLOWING: • GC TO REPLACE ANY EXISTING FLOOR MATERIAL AS SHOWN ON PLANS • GC TO REMOVE EXISTING WALL PAINT AND RE -PAINT AS SHOWN ON PLANS. • GC TO INSTALL ALL DISPLAY FIXTURES AS SHOWN ON FIXTURE PLAN. • GC TO REPLACE GRIDS AND CEILING TILES AS SHOWN. • GC TO COORDINATE WITH CITY INSPECTOR REGARDING ANY ADDITIONAL WORK NEEDED TO MEET CITY/LOCAL CODE REQUIREMENTS. Proiect Owner: Consultant: rhaarclaitect Architect + Master Planner 16043 Barbarossa Drive Houston, Texas 77083 E-mail: RHAcirchitectsOoolkcom WebsIte: rhc3rris@rhaorchitects.net PNt 01 6E�� 94�w gzp� I 1 11 0144 C.11: (832) 545-6319 BussIness: (281) 564-7300 F­ (M) 564-7301 - florida - arkansas - oklahoma - texas - louislana - georgia - mississippi Copyright Protected 2017 Project Address: SAP # 511 D 7333 GALL BLVD SITE:7335 ZEPHYRHILLS, FL 33541 No.l Date Description Sheet Title: COVER SHEET Ill \AN O G� PN�� ,vw DRAWN BY: A DWG. DATE: 01-19-17 1 cu OX REVIEWED BY- AM / AM PROJECT NUMBER TMO 550 TEMPLATE TYPE XX SHEET: A100 EXTERIOR C1 FIXTURE PLAN 1 /8" = 1'-0" FIXTURES GRAPHIC FIXTURES SYMBOL DESCRIPTION SYMBOL DESCRIPTION AC3 ACCESSORY PANEL AF A FRAME SIGN ADA ADA COUNTER BFM BRAND FOCAL MONITOR B BENCH LB LED WINDOW FRAME SIGN CT CONSULTATION TABLE SS STANCHION SIGN DF DIGITAL FRONT WINDOW T DIGITAL FRONT WINDOW DS DIGITAL SIGNAGE WG WALL GRAPHIC DW SALES AREA - WOOD BASE - FT FEATURE TABLE PP POWER POLE STL STOOL SW SYSTEM WALL WB WALL BAY SEE SHEET A601 FOR FIXTURE SCHEDULE. Al FIXTURE SUMMARY NOT ALL USED AT THIS LOCATION NEW PARTITION WALL AND DOORS BY DEALER 3-5/8" METAL STUDS @ 16" O.C. WITH 1/2" GYP. EACH SIDE, TYP. 1. FIXTURES FURNISHED BY OWNER AND INSTALLED BY GENERAL CONTRACTOR OR FIXTURE VENDOR. REFER TO FIXTURE MANUFACTURER INSTRUCTIONS FOR ALL ATTACHMENTS TO WALL AND FLOOR. PROVIDE ALL BLOCKING AND ANCHORS AS REQUIRED. 2. FIXTURE QUANTITIES LISTED ARE FOR REFERENCE ONLY. IT IS OWNER'S RESPONSIBILITY TO VERIFY ALL QUANTITIES AND COORDINATE WITH CASEWORK VENDOR. 3. ALL SERVICE COUNTERTOPS TO COMPLY W/ ANSI / ADA / CHAPTER 11 B. 4. SEE SHEET A601 FOR BRANDED ELEMENT, EIT, EQUIPMENT, FIXTURE, AND GRAPHIC FIXTURE SCHEDULES. 5. G.C. TO FIELD VERIFY ALL DIMENSIONS AND NOTIFY ARCHITECTS IMMEDIATELY OF ANY DISCREPANCIES OR UNFORESEEN ITEMS NOT SHOWN ON DRAWINGS, B4 GENERAL NOTES 1 ,1> TOP OF COUNTER TO BE @ +34" A.F.F. MAX. 2 6x6 INTERNATIONAL SYMBOL OF ACCESSIBILITY AT CORNER OF SALES COUNTER. 3 30" X 48" CLEAR SPACE AT COUNTER. / 4 > DASHED LINES INDICATE 44" WIDE ACCESSIBLE PATH OF TRAVEL. A4 KEYED NOTES I\\.lVIVI I N.I.C. LAYOUT SUMMARY ADJACENTI TENANT TOTAL NUMBER OF POS STATIONS 4 TOTAL NUMBER OF REMOTE STATIONS 0 TOTAL OCCUPANTS 29 TOTAL SQUARE FOOTAGE: 1,620 SQ. FT. SALES AREA: 803 SQ. FT. BACK OF HOUSE: 628 SQ. FT. ACCESSORY: 189 SQ. FT. A6 LAYOUT SUMMARY ADJACENT TENANT CO OR QO POWER POLE. SEE ELECTRICAL DRAWINGS FOR MORE INFORMATION XXX FIXTURE TAG XXX GRAPHIC FIXTURE TAG XXX EQUIPMENT TAG / EIT TAG EXISTING AREA TO REMAIN. N.I.0 A9 SHEET SYMBOLS NOT ALL USED AT THIS LOCATION INTERIOR ELEVATION KEY EXISTING ENTRY DOOR EXISTING STOREFRONT SYSTEM AND GLAZING EXTERIOR_ EXISTING ENTRY DOOR EXISTING STOREFRONT SYSTEM AND GLAZING SEE SHEET A601 FOR SCHEDULES G.C. TO FIELD VERIFY ALL DIMENSIONS AND NOTIFY ARCHITECTS IMMEDIATELY OF ANY DISCREPANCIES OR UNFORESEEN ITEMS NOT SHOWN ON DRAWINGS. Proiect Owner: Consultant: rh aarcliitect Architect + Master Planner 16043 Barbarossa Drive Houston, Texas 77083 E—mail: RHAorchitects(kol.com Website: harris@rhciarchltects.ret Pft "�riR � ni Cell: (832) 545-6319 8—iness: (281) 554-7300 Fox: (281) 564-7301 — florida — arkansas — oklahoma — texas — louisiana — georgia — mississippi Copyright Protected 2017 Project Address: SAP #511D 7333 GALL BLVD SITE:7335 ZEPHYRHILLS, FL 33541 No.l Date Description Sheet Title: FIXTURE PLAN AR98583 C Al, V N 1 DRAWN BY: JN DWG. DATE: 01-19-17 REVIEWED BY: AM / AM PROJECT NUMBER: TMO 550 TEMPLATE TYPE: XX SHEET A101 ADJACENT TENANT 40'-10" 2'-0" T-5" ❑ L- - EXISTING ENTRY i _ \ DOOR (D - EXISTING STOREFRONT SYSTEM AND GLAZING A501 W Z EXTERIOR BACK OF HOUSE N.I.C. b---- N J SALES -- --- AREA _ _ WG-1 4 SIDES W P-2 — LEVEL 4 - B WB-2 --- F I RT-1 - - EXTERIOR I Q w J EXISTING ENTRY 0 DOOR J Z � Al ul W P-2 A5o1 LEVEL 4 ❑ J B F - q N 01 EXISTING STOREFRONT SYSTEM AND GLAZING N _ LEASE LINE TOILET ROOM N.I.C. 2'-0" 5'-2 1 /2" 46'-7" ADJACENT TENANT SEE SHEETA601 FOR SCHEDULES PROVIDE SIGN OVER DOOR STATING: "THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED" LETTERS TO 1" HIGH ON A CONTRASTING BACKGROUND. G.C. TO PROVIDE IF NOT EXISTING NOTE: FOR FLOOR FINISHES, COMPLY WITH THESE RECOMMENDATIONS AT MINIMUM OR NOT LESS THAN MANUFACTURER'S WRITTEN INSTRUCTIONS. REFER TO MANUFACTURER'S INSTALLATION SPECIFICATIONS FOR ALL FINISHES INCLUDING FLOOR LEVELING REQUIREMENTS, EXPANSION SPACES, VAPOR BARRIERS, UNDERLAYMENTS, SITE CONDITIONS, ETC. • SUBFLOOR PREPARATION: GRIND HIGH SPOTS AND FILL LOW SPOTS TO PRODUCE A MAXIMUM 1/8-INCH (3-MM) DEVIATION IN ANY DIRECTION WHEN CHECKED WITH A 10-FOOT (3-M) STRAIGHT EDGE. • EXPANSION: PROVIDE EXPANSION SPACE AT WALLS AND OTHER OBSTRUCTIONS AND TERMINATIONS OF FLOORING OF NOT LESS THAN DIRECTED BY MANUFACTURER. • PROTECTION: PROVIDE FLOOR PROTECTION UP UNTIL FINAL CLEANING. C1 FLOOR PLAN 1/8" = 1'-0" SYMBOL DESCRIPTION 1. MAINTAIN FIRE RESISTANCE RATING FOR ALL TENANT DEMISING WALLS. M— BRANDED ELEMENT - MURAL 2. 3. 4. WHERE EXISTING INSULATION IS REMOVED OR MISSING, PATCH AND REPLACE INSULATION TO MATCH EXISTING CONDITIONS AND MAINTAIN REQUIRED R-VALUES SEE SHEET A501 FOR FLOORING AND FINISH DETAILS PREPARE CONCRETE FLOOR SURFACE FOR INSTALLATION OF NEW FLOORING MATERIALS PER MANUFACTURERS INSTRUCTIONS. EXISTING PARTITION. PATCH AND REPAIR EXISTING DOOR. PATCH AND REPAIR TO TO "AS-NEW'CONDITION AS NECESSARY. — — — "AS-NEW"CONDITION AS NECESSARY. NEW PARTITION AND/OR FURRING TO BE PERMITTED AND INSTALLED BY OTHERS. / NEW 3'-0" X 7'-0" DOOR (UNLESS WR BRANDED ELEMENT - WINDOW WRAP CPT-4 ENTRANCE - WALK -OFF MAT LVT-1 SALES AREA - HARD FLOORING P-2 SALES AREA, TOILET ROOMS, HALLWAY, ETC. AS NOTED ON DRAWINGS - PAINT PT-1 SALES AREA - TILE 5. PROVIDE FIRE EXTINGUISHERS PER FIRE MARSHALL'S INSTRUCTIONS. l OTHERWISE NOTED) AND TRANSITION AS 6. RELOCATE ALL FIRE STROBES, THERMOSTATS AND OTHER WALL MOUNTED DEVICES AS PER LOCAL CODE AS REQUIRED PER NEW FIXTURE LAYOUT. COORDINATE WITH PROJECT MANAGER/ARCHITECT W P-2 WALL FINISH LEVEL 4 LEVEL FINISH B RB-1 BASE FINISH F LVT-1 FLOOR FINISH _ _ _ REQUIRED TO BE PERMITTED AND INSTALLED BY OTHERS. RT-1 SALES AREA - FLOORING RT-2 SALES AREA - FLOORING WB-2 SALES AREA - WOOD BASE 7. G.C. TO FIELD VERIFY ALL DIMENSIONS AND NOTIFY ARCHITECTS IMMEDIATELY OF ANY DISCREPANCIES OR UNFORESEEN ITEMS NOT SHOWN ON DRAWINGS. EXISTING AREA TO REMAIN. N.I.C. XXX BRANDED ELEMENT TAG WD-1 SALES AREA - WOOD FLOORING WG-1 SALES AREA - WALLGUARD *ALL FINISHES TO BE INSTALLED PER MANUFACTURER'S RECOMMENDATIONS. SEE SHEET A601 FOR FINISH AND BRANDED ELEMENT SCHEDULE. Al FINISH SUMMARY A4 GENERAL NOTES A9 SHEET SYMBOLS NOT ALL USED AT THIS LOCATION NOT ALL USED AT THIS LOCATION Project Owner: Consultant: rha$rchitect Architect + Master Planner 16043 Barbarossa Drive Houston, Texas 77083 E—mail: RHAarchitectsCaolxom Website: rharris@rhaarchitects.net � R ?1- Cell: (832) 545-6319 8usslness: (281) 564-7300 Fax: (281) 564-7301 florida — arkansas — oklahoma — texas — louisiana — georgia Mississippi Copyright Protected 2017 Project Address: SAP # 511 D 7333 GALL BLVD SITE:7335 ZEPHYRHILLS, FL 33541 Sheet Title: FINISH PLAN DRAWN BY: J N DWG. DATE: 01-19-17 REVIEWED BY- AM / AM PROJECT NUMBER: TMO 550 TEMPLATE TYPE: XX SHEET: A111 0 I ` L111111, I'111!"IFII q, I.11r. I III Jl': I : p111"Jnll1 111111r1I I 1 1ilvi i! '7wIII WWW11®1ng1impri I 1 1 i ADJACENT! TENANT EXTERIOR ADJACENT TENANT D1 T-MOBILE PREFERRED REFLECTED CEILING PLAN 1/8" = T-0" i I/\ i VI\L I \J ULV'u r\I IV\7 i VI\ J i PY Li LILP•11 IVIN. SEE SHEET A601 FOR SCHEDULES G.C. TO FIELD VERIFY ALL CEILING HEIGHTS AND NOTIFY ARCHITECTS IMMEDIATELY OF ANY DISCREPANCIES OR UNFORESEEN ITEMS NOT SHOWN ON DRAWINGS. 1. ELECTRICAL EQUIPMENT, HVAC EQUIPMENT, AND SPRINKLERS ARE TO BE MOUNTED AT POINTS IN ACP AS NOTED IN SYMBOL DESCRIPTION GRAPHIC BELOW UNLESS OTHERWISE DIMENSIONED ON RCP. REFER TO EDSS INSTALL GUIDELINES FOR LIGHTING. SYMBOL DESCRIPTION SYMBOL DESCRIPTION 2X2 ACT TILE 2X4 ACT TILE - - ____-. O ❑o SINGLE HEAD ADJUSTABLE SURFACE MOUNTED 2'x2' ARMSTRONG - FINE FISSURED SECOND LOOK- w DESIGNER SERIES 1761, Uw' COLOR: WHITE, 24"X48" TEGULAR EDGE, ARMSTRONG SINGLE HEAD ADJUSTABLE FOR PRELUDE XL 15/16" TEE GRID. Q, Q. EQ. EQ. EQ. EQ. ❑O EMERGENCY OPERATION — - - SURFACE MOUNTED 2'x2' FOR ACP-1 2. CENTER ACT GRID WITHIN EACH ROOM UNLESS OTHERWISE NOTED. EMERGENCY OPERATION ---— O O DUAL HEAD ADJUSTABLE 3. NO CEILING REQUIRED IN JANITORS CLOSET, IF APPLICABLE. 4. PLACEMENT AND NUMBER OF EMERGENCY LIGHTS, NIGHT LIGHTS, AND EXIT LIGHTS ALONG WITH MOUNTING HEIGHT EXISTING TILE AND 24"X48 TEE GRID. G.C. TO REPAIR AS NEEDED DUAL HEAD ADJUSTABLE FOR AND REPLACE INDIVIDUAL CEILING TILES WITH NEW. IF MORE TO BE CONFIRMED BY PARTNER'S ARCHITECT/ENGINEER. SPECIFICATIONS SHOWN ARE FOR REFERENCE ONLY. O O EMERGENCY OPERATION PENDANT MOUNTED 2'x2' THAN 25% OF CEILING TILES ARE DAMAGED, G.C. TO REPORT z CONDITION AND COORDINATE EXTENT OF REPLACEMENT WITH 5. GC TO ADJUST PERIMETER ADJUSTABLE LIGHTS TO BE TARGETED BETWEEN 5'-9" TO 6'-3" VERTICALLY FROM FLOOR PROJECT MANAGER/ARCHITECT TO WASH RETAIL WALL DISPLAYS. —---- ACP-2 6. G.C. TO FIELD VERIFY ALL DIMENSIONS AND NOTIFY ARCHITECTS IMMEDIATELY OF ANY DISCREPANCIES OR O O O TRIPLE HEAD ADJUSTABLE PENDANT MOUNTED 2'x2' FOR UNFORESEEN ITEMS NOT SHOWN ON DRAWINGS. r EMERGENCY OPERATION G.0 SHALL INSTALL CEILING _ IN ACCORDANCE WITH TRIPLE HEAD ADJUSTABLE FOR ARMSTRONG - DESIGNER SERIES 737, 5/8" THICK, ICC ESR 1308 O O O z CEILING MOUNTED VENTILATION FAN EMERGENCY OPERATION COLOR: WHITE, 24"X24" ANGLED TEGULAR EDGE, ICC ESR 1289 WITH LED LIGHT MOTION SENSOR. i ARMSTRONG PRELUDE XL 15/16" TEE GRID IBC SECTION 2508 GC TO CONTACT ARMSTRONG WORLD INDUSTRIES CUSTOMER - - SERVICE REP FOR T-MOBILE PREFERRED PRICING AND TO LOCATE EXIT SIGN WITH BATTERY BACKUP GENERAL CONTRACTOR SHALL FIELD VERIFY LOCAL DISTRIBUTOR OF ARMSTRONG PRODUCTS. GC TO CONFIRM RECESSED 2'x2' ACP-3 EXISTING EGRESS LIGHTING AND PROVIDE WITH LOCAL DISTRIBUTOR ORDER IS FOR T-MOBILE PROJECT: - -- -- — NEW EMERGENCY LIGHT FIXTURES AS REQUIRED BY FIRE MARSHALL CONTACT SHERRY BRUNT OR BETH RINEHART — EMERGENCY LIGHTING FOR NEW: 5/8" GYPSUM BOARD OVER 3 5/8" METAL CUSTOMER SERVICE REPRESENTATIVES FRAMING MEMBERS @ 16" O.C. FINISH TO BE P-2. GC TO CONTACT EDSS ENERGY DESIGN SERVICE ARMSTRONG WORLD INDUSTRIES, INC. RECESSED 2'x2' FOR EMERGENCY — SEE FINISH SCHEDULE SHEET A-7. SYSTEMS FOR T-MOBILE PREFERRED PRICING: PO BOX 3001 OPERATION LANCASTER, PA 17604 R D TRACK LIGHTING CONTACT MICHAEL NORDLOH PHONE: 800-442-4212 FOR EXISTING: 5/8" GYPSUM BOARD OVER EXISTING 810-227-3377 FAX: 800-233-5598 ' SEE G1/A601 FOR T-MOBILE PREFERRED LIGHTING SCHEDULE METAL FRAMING MEMBERS @ 16" O.G. FINISH TO BE MNORDLOH@EDSSENERGY.COM EMAIL: BPO_STRATEGIC ACCOUNTS@ARMSTRONG.COM AND D1/A601 FOR ALTERNATE LIGHTING SCHEDULE IACP-1 CEILING SYSTEM / FINISH GYP P-2 SEE FINISH SCHEDULE SHEET A-7. 10'-6" K. F. F.J CEILING HEIGHT Al CEILING SUMMARY A4 GENERAL NOTES _ A9 SHEET SYMBOLS NOT ALL USED AT THIS LOCATION NOT ALL USED AT THIS LOCATION Project Owner: Consultant: rh aarchitect Architect + Master Planner 16043 Barbarossa Drive Houston, Texas 77063 E-mail: RHAarchitects@aol.com Website: rharris®rhaarchitects. ret Cell: (832) 545-6319 Busslnese: (281) 564-7300 Fax: (281) 564-7301 - florida - arkansas - oklahoma - texas - louisiana - georgia - Mississippi Copyright Protected 2017 Project Address: SAP # 511 D 7333 GALL BLVD SITE:7335 ZEPHYRHILLS, FL 33541 No. Date Description Sheet Title: REFLECTED CEILING PLAN DRAWN BY: JN DWG. DATE: 01-19-17 REVIEWED BY: AM / AM PROJECT NUMBER: TMO 550 TEMPLATE TYPE: XX SHEET: A121 Proiect Owner: G1 1/8" = 1'-0" T T Q I INTERIOR ELEVATION RArlll IT i BACKLIT i D1 INTERIOR ELEVATION D7 INTERIOR ELEVATION 1 /8" = T-0" 1 /8" = T-0" Al INTERIOR ELEVATION 1 /8" = T-0" EXISTING STOREFRONT SYSTEM AND GLAZING-7 r-F WB-2 EXISTING ENTRY DOOR A7 EXISTING ENTRY DOOR DFW30 �11 i MAnin 1-r I 0 J W LL Z } LL ry W Consultant: rhaarchitect Architect + Master Planner 16043 Barbarossa Drive Houston, Texas 77083 E—mail: RHAarchitects(Pool.com Website: rharris@rhaarchitects.net ". 11R Ceil: (832) 545-6319 B-1..ss: (281) 564-7300 Fax: (281) 564-7301 — florida — arkansas — oklahoma — texas — louisiana — georgia — mississippi Copyright Protected 2017 Project Address: SAP # 511D 7333 GALL BLVD SITE-7335 ZEPHYRHILLS, FL 33541 Sheet Title: INTERIOR ELEVATIONS DRAWN BY: JN DWG. DATE: 01-19-17 PROJECT NUMBER: TMO 550 TEMPLATE TYPE: XX SHEET: A201 G.C. SHALL VERIFY THAT THE SHOWN METHOD OF ATTACHMENT IS ACCEPTABLE WITH THE ON -SITE COORDINATOR. IF NOT, CONTACT ARCHITECT FOR ALTERNATE DETAIL. EXISTING " X 2" X 1/4" METAL 'L' @ ROOF DECK 6'-0" O.C. ATTACH TO TOP CHORD OF EXIST, BAR EXISTING JOISTS. (VERIFY TRUSS. V.I.F. CONDITION) I I I I I I G.C. TO PROVIDE 1/2 i\`v \��\ i DIAGONAL PLYWOOD I BRACING TOP �` `` FOF I STUD TO BLOCKING I BOTTOM OF ATTACHED TO NEW I ` I OR EXISTING 3 5/8" X I �� �� l l ADJACENT STUD �`� 20 GA METAL STUDS i i i°`� FOR DECK TO STRUCTURE I I I °I HEIGHT OVER ABOVE. V.I.F. i i t� °i 14'-0" A.F.F. OR 1 AS REQUIRED. I I I I I I emc I PROVIDE ACCESS�EXISTING PANEL FOR 1A CEILING TYPE GYP. CEILING. VARIES \....d-BOXES DIGITAL FOR DISPLAY POWER/DATA. FIXTURE SEE E-1.4 E1 DFM/DFW ATTACHMENT N.T.S. FOR FULL HEIGHT FIXTURES ONLY A4 BASE FINISH DETAIL - WOOD A7 RESILIENT COVE BASE - SALES AREA N.T.S. 3" = 1'-0" OOR IN CLOSED POSITION SALES AREA EXTERIOR LOW PROFILE ALUM. THRESHOLD SMOKE GASKET SWEEP (PEMKO 156A - MILL FINISH OR SIM.) NOTCH WB-2 OVER EXISTING DOOR TRIM CARPET BACK TO EXISTING CONCRETE JAMBS, TYP. RUN CONTINUOUS LINE OF CAULK AT JOINT AND PAINT P-2 FINISH. LOWEST POINT TO ABUT SLAB ON GRADE EXISTING THRESHOLD. X X Q 1 4"�vl X2"MAX. SEE S INSTRUCTIONS FOR WD-1 EXPANSION V CV GYP. BD. 1 1.0 00 . VERIFY GYP. BD. EXISTING ENTRY THRESHOLD - EXTERIOR TO WALK -OFF MAT WOOD BASE SALES AREA SYSTEM WALL BOTTOM TRIM CPT HEIGHT VARIATION ANGLE X Q 0. 57� MAX. C MPRESSED CPT 0.1564 MAX.AS WOOD OR METAL BLOCKING A00 NECESSARY FORLO N BELOW THRESHOLD FASTENING OF BASE ©Q SEE MFR SEE MFR FACET FURSTRAIGHTTE CK ANDND 5 v /4 D Q SHIM CPT EDGE TO MATCH SPECIFICATIONS FOR FLOORING TOP OF FLOORING SPECIFICATIONS FOR FLOORING INSTALLED BY FIXTURE `O MFR. CUT TO LENGTH AND a TRANSITION HT. AS REQUIRED OR i SCHLUTER TRANSITION STRIP EXPANSION, TYP. EXPANSION, PAINT ENDS TO MATCH TRIM CPT BACK TO THICKER RIDGE RENO-V AEVT125B20 (112") TYP. WILSONART DESIGNER WHITE D354 TOP OF FLOORING X WALK OFF ENTRY MAT d D Q RT-1 ZW MAX. p NQ r7\7 N Q D D a D a a �? a EXISTING a D CONCRETE VAAREE PAD/SUBFLOOR VA1f R LVT-1 - TO - WALK OFF MAT Al FLOORING TRANSITION DETAILS A4 NOT USED A7 WOOD BASE A10 TOE KICK & FACE PLATE N.T.S. 3" = 1'-01, 3" = 1'-0" I Project Owner: Consultant: rhaarcliaect Architect +Master Planner 16043 Barbarossa Drive Houston, Texas 77083 E-mail: RHAarchitects@aol.com Webslte: rharris®rhaarchitects.net pkm w _ w n Cell: (832) 545-6319Cell: (832) 545-6319 Suss(ness: (281) 564-7300 Fax: (281) 564-7301s(281) 564-7300 Fax: (281) 564-7301 - florida - arkansas - oklahoma - texas - louisiana - georgia - mississippi Copyright Protected 2017 Project Address: SAP # 511 D 7333 GALL BLVD SITE:7335 ZEPHYRHILLS, FL 33541 Sheet Title: DETAILS _ pp DRAWN BY: J N DWG. DATE: 01-19-17 REVIEWED BY: AM / AM PROJECT NUMBER: TMO 550 TEMPLATE TYPE: XX SHEET: A501 Project Owner: CALLOUT SYMBOL DESCRIPTION MODEL LAMP INPUT WATTS BALLAST VOLTS MOUNTING NOTES LED-ML1 SINGLE HEAD ADJUSTABLE GIMBAL RING 358'H X 45'V, HOUSING M/N:NMRI-11 N1020 SATCO: 11 W ELECTRONIC 120V 1 P RECESSED COMPLETE ASSEMBLY INCLUDES: HOUSING, TRIM, AND (2) FO 40' LEDPAR30, FLUSH MOUNT FIXTURE TRIM MIN: NMRT-1 F1 652WW 11PAR30-SN-LED-40-4000K-120V-D C-CHANNEL BAR HANGERS C-CHANNEL MIN: NRA-38 LED-ML1-EM SINGLE HEAD ADJUSTABLE GIMBAL RING 358'H X 45'V, HOUSING M/N:NMRI-11 N1020 SATCO: 11W ELECTRONIC 120V 1 P RECESSED COMPLETE ASSEMBLY INCLUDES: HOUSING, TRIM, (2) C-CHANNEL �O 40' LEDPAR30, FLUSH MOUNT FIXTURE - WIRED TO TRIM MIN: NMRT-1F1652WW I IPAR30-SN-LED-40-4000K-120V-D BAR HANGERS, AND WIRED TO MINI -INVERTER FOR EMERGENCY MINI -INVERTER FOR EMERGENCY OPERATION C-CHANNEL MIN: NRA-38 OPERATION W/ 90 MINUTE BATTERY BACKUP LED-ML2 DUAL HEAD ADJUSTABLE GIMBAL RING HOUSING M/N:NMRI-12N1020 SATCO: 22W ELECTRONIC 120V 1 P RECESSED COMPLETE ASSEMBLY INCLUDES: HOUSING, TRIM, AND (2) O O 358'H X45'V, 40' LEDPAR30, FLUSH MOUNT FIXTURE TRIM MIN: NMRT-1F2652WW 11PAR30-SN-LED-40-4000K-120V-D C-CHANNEL BAR HANGERS C-CHANNEL MIN: NRA-38 LED-ML2-EM DUAL HEAD ADJUSTABLE GIMBAL RING 358'H X 45'V, HOUSING M/N:NMRI-12N1020 SATCO: 22W ELECTRONIC 120V 1 P RECESSED COMPLETE ASSEMBLY INCLUDES: HOUSING, TRIM, (2) C-CHANNEL O O 40' LEDPAR30, FLUSH MOUNT FIXTURE - WIRED TO TRIM MIN: NMRT-IF2652WW 11PAR30-SN-LED-40-4000K-120V-D BAR HANGERS, AND WIRED TO MINI -INVERTER FOR EMERGENCY MINI -INVERTER FOR EMERGENCY OPERATION C-CHANNEL MIN: NRA-38 OPERATION W/ 90 MINUTE BATTERY BACKUP LED-ML3 TRIPLE HEAD ADJUSTABLE GIMBAL RING 358'H X 45'V, HOUSING M/N:NMRI-13N1020 SATCO: 33W ELECTRONIC 120V 1 P RECESSED COMPLETE ASSEMBLY INCLUDES: HOUSING, TRIM, AND (2) O O O 40' LEDPAR30, FLUSH MOUNT FIXTURE TRIM MIN: NMRT-lF3652WW 11PAR30-SN-LED-40-4000K-120V-D C-CHANNEL BAR HANGERS C-CHANNEL MIN: NRA-38 LED-ML3-EM TRIPLE HEAD ADJUSTABLE GIMBAL RING 358'H X 45'V, HOUSING M/N:NMRI-13N1020 SATCO: 33W ELECTRONIC 120V 1 P RECESSED COMPLETE ASSEMBLY INCLUDES: HOUSING, TRIM, (2) C-CHANNEL 1000 40' LEDPAR30, FLUSH MOUNT FIXTURE - WIRED TO TRIM M/N: NMRT-1 F3652WW 11 PAR30-SN-LED-40-4000K-120V-D BAR HANGERS, AND WIRED TO MINI -INVERTER FOR EMERGENCY MINI -INVERTER FOR EMERGENCY OPERATION C-CHANNEL MIN: NRA-38 OPERATION W/ 90 MINUTE BATTERY BACKUP LED-LC2-R RECESSED 2'x2' LED EDGE -LIT FLAT DIMMABLE PANEL, NPD-E2243-40-W INTEGRATED LED 36W ELECTRONIC 120/277V RECESSED 4000K, WHITE PAINTED ALUMINUM FINISH RECESSED MOUNTING KIT MIN: NPD-22RFK-A LED-LC2-R-EM RECESSED 2'x2' LED EDGE -LIT FLAT DIMMABLE PANEL, NPD-E2243-40-W INTEGRATED LED 36W ELECTRONIC 120/277V RECESSED WIRED TO MINI -INVERTER FOR EMERGENCY OPERATION WITH 90 4000K, WHITE PAINTED ALUMINUM FINISH, WIRED TO RECESSED MOUNTING KIT MIN: MINUTE BATTERY BACKUP MINI -INVERTER FOR EMERGENCY OPERATION NPD-22RFK-A LED-LC2-S SURFACE 2'x2' LED EDGE -LIT FLAT DIMMABLE PANEL, NPD-E2243-40-W INTEGRATED LED 36W ELECTRONIC 120/277V SURFACE 4000K, WHITE PAINTED ALUMINUM FINISH SURFACE MOUNTING KIT MIN: NPD-22DFK-A LED-LC2-S-EM SURFACE 2'x2' LED EDGE -LIT FLAT DIMMABLE PANEL, NPD-E2243-40-W INTEGRATED LED 36W ELECTRONIC 120/277V SURFACE WIRED TO MINI -INVERTER FOR EMERGENCY OPERATION WITH 90 4000K, WHITE PAINTED ALUMINUM FINISH, WIRED TO SURFACE MOUNTING KIT MIN: MINUTE BATTERY BACKUP MINI -INVERTER FOR EMERGENCY OPERATION NPD-22DFK-A LED-LC2-P PENDANT 2'x2' LED EDGE -LIT FLAT FIXTURE MIN: NPD-E2243-40-W - 38W ELECTRONIC 120/277V PENDANT DIMMABLE PANEL, 4000K, WHITE PAINTED PENDANT MOUNTING KIT MIN: NPD-PK ALUMINUM FINISH LED-LC2-P-EM PENDANT 2'x2' LED EDGE -LIT FLAT DIMMABLE PANEL, FIXTURE MIN: NPD-E2243-40-W - 38W ELECTRONIC 120/277V PENDANT MINI -INVERTER WITH 90 MINUTE BATTERY 4000K, WHITE PAINTED ALUMINUM FINISH, WIRED TO PENDANT MOUNTING KIT MIN: NPD-PK BACKUP BOH INVERTER FOR EMERGENCY OPERATION INVERTER MIN: LV-3-R-1-B2002 LED-EF PANASONIC CEILING MOUNTED VENTILATION FAN FIXTURE MIN: FV-11-15VKL1 LED 14W ELECTRONIC 120V 1P RECESSED PROVIDE WALL MOUNTED OCCUPANCY SENSOR WITH LED LIGHT LED-EM NORA LIGHTING BEVELED INTEGRAL DUAL HEAD FIXTURE MIN: NE-806-W LED - ELECTRONIC 120/277V SURFACE CEILING/WALL MOUNTED EMERGENCY LIGHT WITH BATTERY BACKUP 90 MINUTE BATTERY BACKUP LED-EXT NORA LIGHTING WHITE LED EXIT SIGN WITH BATTERY FIXTURE MIN: NX-603-LEDR LED 2W ELECTRONIC 120V 1 P SURFACE 90 MINUTE BATTERY BACKUP BACKUP LED-TH = _ = SINGLE HEAD ADJUSTABLE TRACK HEAD NORA LIGHTING SATCO: 11 W ELECTRONIC 120V 1 P SURFACE NORA LIGHTING NT-300 SERIES ~ ~ ~ NTH-125-W 11PAR30-SN-LED-40-4000K-120V-D ONE -CIRCUIT TRACK BR301PAR30 CONE D1 LIGHTING SCHEDULE NOT ALL USED AT THIS LOCATION FIXTURE SCHEDULE COMPLETE LIGHTING PACKAGE IS OWNER FURNISHED, GC INSTALLED, CONTACT EDSS (ENERGY DESIGN SERVICE SYSTEMS) FOR COMPLETE LIGHTING PACKAGE INCLUDING ALL LIGHT FIXTURES, LCP, MINI -INVERTER, SWITCHES, SENSORS, TVSS AND FLOOR BOXES. REFER TO EDSS INSTALLATION INSTRUCTIONS. NAME QUANTITY DESCRIPTION NAME FT_4B FT_6B FT_MT PP 1 PP 2 SC-1 SC_1A SC-2 SC PRT STL_2 STL 3 SW SW1 2 QUANTITY DESCRIPTION NEW EXIST NEW EXIST AC3_6 1 0 ACCESSORY PANEL W/USB - APPLE 1 0 FEATURE TABLE - 4'-0" - METAL - POWER POLE AC3_7 1 0 ACCESSORY PANEL W/USB - SAMSUNG 0 0 FEATURE TABLE - 6-0" - METAL - POWER POLE AC3_8 1 0 ACCESSORY PANEL W/USB - FLEX/AUDIO 0 0 FEATURE TABLE - MULTI TIER AC3_9 1 0 ACCESSORY PANEL W/USB - ANDROID 2 0 POWER POLE LARGE AC3_10 1 0 ACCESSORY PANEL W/USB - TABLETS 1 0 POWER POLE SMALL AC3_11 1 0 ACCESSORY PANEL W/USB - OVERFLOW 0 0 SERVICE COUNTER, SINGLE ADA 1 0 ADA COUNTER 0 0 SERVICE COUNTER, SINGLE ADD -ON B1 0 0 BENCH - PRIMARY 4' W/ INSET 2 0 SERVICE COUNTER, DOUBLE B2 0 0 BENCH - SECONDARY 4' 1 0 SERVICE COUNTER, PRINTER CT-4 0 0 CONSULTATION TABLE - 4 SEATS 4 0 STOOL CT-6 0 0 CONSULTATION TABLE - 6 SEATS 1 0 ADA STOOL DFM 0 0 DIGITAL FRONT WINDOW - 6" 22 0 SYSTEM WALL PANEL - 47 1/4" DFM F 0 0 DIGITAL FRONT WINDOW - 6" FREESTANDING 0 0 SYSTEM WALL PANEL - 23 5/8" DFW 1 0 DIGITAL FRONT WINDOW - 8" DFW F 0 0 DIGITAL FRONT WINDOW - 8" FREESTANDING IDS 1 0 DIGITAL SIGNAGE DS_R 0 0 DIGITAL SIGNAGE - WITH REMO DWJ 1 0 DISPLAY WALL J - APPLE DWK 1 0 DISPLAY WALL K - SAMSUNG DWL 2 0 DISPLAY WALL L - FLEX/AUDIO DWM 2 0 DISPLAY WALL M - ANDROID DWN 2 0 DISPLAY WALL N - TABLETS DWP 1 0 DISPLAY WALL P - OVERFLOW Al I SALES AREA FIXTURE SCHEDULE NOT ALL USED AT THIS LOCATION BRANDED ELEMENTS NAME QUANTITY DESCRIPTION NEW EXIST M S 0 0 MURAL SMALL M_M 0 0 MURAL MEDIUM M L 0 0 MURAL LARGE WR 0 0 WINDOW WRAP GRAPHIC FIXTURE SCHEDULE NAME QUANTITY DESCRIPTION NEW EXIST AF1 1 0 A FRAME SIGN BFM 65NS 1 0 BRAND FOCAL MONITOR - 65" NO SHROUD BFM 82NS 0 0 BRAND FOCAL MONITOR - 82" NO SHROUD LB1 0 0 LED WINDOW FRAME SIGN SS1 0 0 STANCHION SIGN T89 0 0 WINDOW CABLE DISPLAY WG1 0 0 WALL GRAPHIC, 40x58 WG2 2 0 WALL GRAPHIC, 76x58 WG3 0 0 WALL GRAPHIC, 112x58 FIXTURES FURNISHED BY OWNER AND INSTALLED BY GENERAL CONTRACTOR OR FIXTURE VENDOR. REFER TO FIXTURE MANUFACTURER INSTRUCTIONS FOR ALL ATTACHMENTS TO WALL AND FLOOR. PROVIDE ALL BLOCKING AND ANCHORS AS REQUIRED. CONTACT: MICHAEL NORDLOH 810.227.3377 MNORDLOH@EDSSENERGY.COM EQUIPMENT SCHEDULE NAME QUANTITY DESCRIPTION NEW EXIST BWP 2 0 PRINTER MFP 1 0 COLOR MULTI FUNCTION PRINTER XCQ 0 0 XEROX COLOR CUBE XMFP 0 0 XEROX MULTI -FUNCTION PRINTER EIT SCHEDULE NAME QUANTITY DESCRIPTION NEW EXIST 13 1 0 BRAND FOCAL CONTENT 14 0 0 DIGITAL SIGNAGE - CORE CONTENT 30 1 0 DIGITAL FRONT WINDOW - COMBO 32 0 0 DIGITAL SIGNAGE - PRIMARY RIGHT 33 0 0 DIGITAL SIGNAGE - PRIMARY LEFT 34 1 0 DIGITAL SIGNAGE - PRIMARY COMBO 35 0 0 DIGITAL FRONT WINDOW - PRIMARY 36 0 1 0 DIGITAL FRONT WINDOW - SECONDARY 37 0 0 DIGITAL SIGNAGE - SECONDARY RIGHT 38 0 0 DIGITAL SIGNAGE - SECONDARY LEFT 39 0 0 DIGITAL SIGNAGE - SECONDARY COMBO FIXTURE QUANTITIES LISTED ARE FOR REFERENCE ONLY. IT IS OWNER'S RESPONSIBILITY TO VERIFY ALL QUANTITIES AND COORDINATE WITH CASEWORK VENDOR. FLAME SPREAD / SYMBOL DESCRIPTION SMOKE DEVELOPED CPT-4 ENTRANCE - WALK -OFF MAT: MATS INC. LEGACY NOP, FOOT GRILLE ROLL 9/16" THICK CLASS A COLOR: BLACK WALNUT INSTALLATION: RECESSED GLUE DOWN WITH MI MULTI -BOND ADHESIVE CHAPCO SAFE -SET 3 VESTIBULES: MATS INC. SUPREME NOP ROLL 7/16" THICK COLOR: BLACK WALNUT RECESSED GLUE DOWN WITH MI MULTI -BOND ADHESIVE CHAPCO SAFE -SET 3 LVT-1 SALES AREA - HARD FLOORING: ADORE LUXURY VINYL TILE NATURELLE (GLUE DOWN) PRODUCT# DW-1925 CLASS A WOOD EMBOSSING WITH 12 MILL WEAR LAYER SIZE: 7.2"X48", 3MM GAUGE USE WITH TAYLOR ADHESIVE FOR GLUE DOWN PRODUCT# TAY 209165 - 4GAL - AMOUNT VARIES BY STORE. PER MFR SPECS. P-2 SALES AREA, TOILET ROOMS, ETC. AS NOTED ON DRAWINGS - PAINT: CLASS A BENJAMIN MOORE & COMPANY COLOR:#OC-61 - "WHITE DIAMOND" FINISH WALLS: EGGSHELL FINISH CEILING: FLAT FINISH DOOR FRAMES: DTM LATEX SEMI -GLOSS PT-1 SALES AREA TILE: DALTILE - COLORBODY PORCELAIN INDUSTRIAL PARK, COLOR: CHARCOAL BLACK IP09 SIZE: 24" X 24" X 3/8" INSTALL PER MANUFACTURER RECOMMENDATIONS. GROUT: MAIPEI - 47 CHARCOAL, NO SUBSTITUTIONS RT-1 SALES AREA - FLOOR MOHAWK GROUP - HARD SURFACE CLASS A HOT & HEAVY - LOOSE LAY RESILIENT TILE SECOYA (C0009), COLOR: 872 PICTON PARK SIZE: (NOMINAL) 9" X 59" X 5MM INSTALL PER MANUFACTURER RECOMMENDATIONS, RT-2 SALES AREA - FLOOR MOHAWK GROUP - HARD SURFACE CLASS A HOT & HEAVY - LOOSE LAY RESILIENT TILE SECOYA (C0009), COLOR: 872 PICTON PARK SIZE: (NOMINAL) 9" X 59" X 5MM INSTALL PER MANUFACTURER RECOMMENDATIONS. WB-2 SALES AREA - WOOD BASE: 5 3/4"XV W/ RADIUS EDGE, PAINTED P-2. SEE A7/A501. CLASS C WD-1 SALES AREA - WOOD FLOORING: KAH 301116681640401 KAHRS SMOKE OAK HARDWOOD 3-STRIP, 14 MM THICK, +T X 7.4"W X 89.21 "L CLASS C MATTE FINISH 36.69 SF PER CTN (8 PLANKS) OVER VERSASHIELD (PER MANUFACTURER SPECIFICATIONS AND INSTALLATION INSTRUCTIONS). WG-1 SALES AREA - WALLGUARD: WALLGUARD - DEFENDER SERIES 2325.1 N/A 900 1-1/2" CORNER GUARD. RIGID VINYL, UNDRILLED, UNTAPED, 4' LENGTH COLOR: "WHITE" MOUNTED ON TOP OF WALL BASE. A10 I FINISH SCHEDULE NOT ALL USED AT THIS LOCATION ALL FINISHES TO BE INSTALLED PER MANUFACTURER SPECIFICATIONS AND INSTALLATION INSTRUCTIONS. Consultant: rha.architect Architect + Master Planner 16043 Barbarossa Drive Houston, Texas 77083 E—mail: RHAarchitectsQaol.com Website: rharris@rhaarchitects.net i CO: (832) 545-6319 Busslness: (281) 564-7300 Faa: (281) 564-7301 — florida — arkansas — oklahoma — texas — louisiana — georgia — Mississippi Copyright Protected 2017 Project Address: SAP # 511 D 7333 GALL BLVD SITE:7335 ZEPHYRHILLS, FL 33541 Sheet Title: SCHEDULE DRAWN BY: JN DWG. DATE: 01-19-17 REVIEWED BY: AM / AM PROJECT NUMBER: TMO 550 TEMPLATE TYPE: XX SHEET: A601 1O SHOW WINDOW RECEPTACLE(S). LOCATE 18" FROM TOP OF WINDOW (NEC 210.62), ONLY IF NOT EXISTING. 2O PROVIDE OVERHEAD AP CABLING ABOVE CEILING T-0" MIN. 3❑ LED BACK LIGHTING OUTLET MOUNTED AT 68-1/4" A.F.F. PROVIDE LOCK ON DEVICE ON BREAKER AT ELECTRIC ADJACENT PANEL. TENANT O GEARBOX (GB): FOR FIXTURES MOUNTED ON DRYWALL ELECTRICAL CONTRACTOR TO PROVIDE AND INSTALL PERIMETER MOUNTS (MODEL # GB-INWAVP IN WALL AV CABLE AND POWER GEAR BOX.) FOR ACC FIXTURES ONLY PROVIDE AND INSTALL LEGRAND TM8USB4 USB QUAD RECEPTACLE INTO IN -WALL GEAR BOX. 3 3/4" 11 3/4" 1'-2" 4 1/2' 2 3/4" 5'-7 1 /4" '-3 3/4" T-7 1/2" 2'-11 1 /4' 2'-9 1 /4" 3'-7 1/2" 1 -5 112 T-6 114" 3'-2" 2'-7 1 /4" 6'-1 3/4" ol O PROVIDE CIRCUIT(S) AND LOW VOLTAGE WIRING AS REQUIRED TO J-BOXABOVE CEILING FOR TRENCH TO - _ ~I �I ❑ FLOOR FIXTURES. �I � ap Yap oo co ap 6O FIELD VERIFY LOCATION OF EXISTING CONVENIENCE OUTLETS AND ADD ADDITIONAL AS REQUIRED. M "� '+ + + Q Q' N V '+ + p p U M (o p + p + p p + .( ❑7 POWER POLE TO SC-1/SC-2 — — — — q\-L�__J _ — _ — _ — — SEE WIRING DETAILS ON SHEET E501. 6 — — — L— — J • CONDUIT SCHEDULE: SC-1: (1) 3/4" DEDICATED POWER, (1) 3/4" GENERAL POWER. 4 DATA + 2 FUTURE SC-1 +ADA: (1) 3/4" DEDICATED POWER, (1) 3/4" GENERAL POWER. Q 6 DATA + 2 FUTURE L, SC-1 + SC PRT: (1) 3/4" DEDICATED POWER, (1) 3/4" GENERAL POWER. a� SALES — 8 DATA + 2 FUTURE o SC-1 +ADA + SC_PRT: (1) 3/4" DEDICATED POWER, (1) 3/4" GENERAL POWER. AREA N EXTERIOR 10 DATA + 2 FUTURE r SC 2: (1) 3/4" DEDICATED POWER, (1) 3/4" GENERAL POWER. 8 DATA + 4 FUTURE BACK OF HOUSE 10'-9 1/2" 7-I 3-� II 13'-3 1/2" -1 7 r — -I 2 FT_4B SC-2 +ADA: (1) 3/4" DEDICATED POWER, (1) 3/4" GENERAL POWER. I I I I II I I -- F — — -I 10DATA+4FUTURE + SC_PRT: (1) 3/4" DEDICATED POWER, (1) 3/4" GENERAL POWER. 12 DATA + 4 FUTURE N I C " II %—�� ——�SC2 --- _ III I II X2X2 I L — -J I I \ E SC_2+SC_PR++ADA: (1) 3/4" DEDICATED POWER, (1) 3/4" GENERAL POWER. 14 DATA 4FUTURE eo'N - -�� — — — — -—J----J #SC-2 f 8 �� I ��� I ❑ I SC-2 SC PRT ADA SC-2 + SC_1A: (1) 3/4" DEDICATED POWER, (1) 3/4" GENERAL POWER. - - 3 - - 12 DATA + 6 FUTURE 15'-6 1/2" SC-2 + SC_1A + ADA: (1) 3/4" DEDICATED POWER, (1) 3/4" GENERAL POWER. 19 + " —I 14 DATA + 6 FUTURE N p _ o II b SC_2 + SC_1A + SC-PRT: (1) 3/4" DEDICATED POWER, (1) 3/4" GENERAL POWER. 8 -_ - I 11 16 DATA + 6 FUTURE SC-2 + SC_1A + SC-PRT + ADA: (1) 3/4" DEDICATED POWER, (1) 3/4" GENERAL POWER.1O� 3 0) 18 DATA +6 FUTURE r'N 3 3 3 3 3 9 �-, O SC-2 + SC_1A + SC Al: (1) 3/4" DEDICATED POWER, (1) 3/4" GENERAL POWER. w 16 DATA + 8 FUTURE I r r- -1 r- DFW - o • ELECTRICAL CONTRACTOR TO PROVIDE: CONDUIT AND J-BOXES ABOVE CEILING FOR POWER POLE. — — _ — — — — L _J w� PROVIDE POWER FROM PANEL TO CEILING MOUNTED J-BOXES. LEAVE FLEX CONNECTION ASSEMBLY - - - - - - - - - - - - - - - - - - - - - - - - - - - - - COILED AND TAPED AS REQUIRED UNTIL FIXTURE INSTALLATION. AFTER FIXTURE INSTALLATION ELECTRICAL CONTRACTOR TO PROVIDE APPROVED FLEX CONNECTION ASSEMBLY TO POWER SOURCE �I Lo = III ao'= ROUTED THROUGH POWER POLE TO E.C. PROVIDED POWER RECEPTACLES IN PRE -INSTALLED BLANK _ e0 MI M 0�0 � 11 1/2" INSIDE PULL FROM BOARD TO SURFACE MOUNTED U p M LL ap Q p + p + JBOXES -BOXES F XTURE FOR CATSDE E DATA CABLING(S) AND RJ45 JACKS CKS BY OWNERS VENDOR. TOILET Q 1+ 1 • OWNER'S VENDOR TO PROVIDE: CAT5E DATA CABLING, RJ45 JACKS AND PLASTIC GROMMET TO FIT 3/4" ROOM 4'-3 3/4" 3'-7 1/2" T-10" m 6'-7 3/4' 7-10 1/4 1 -4 3-7 1/2' 2 1/2',T-10 KNOCK OUTS IN PRE -INSTALLED BLANK DUPLEX BOX BY FIXTURE MANUFACTURER AS REQUIRED. ROUTE CABLING THROUGH CASEWORK AND MAKE CONNECTIONS TO RJ45 JACKS, TYP. N.I.C. 1/4" 1'-2 1/2" 5" ❑8 POWER POLE TO FT_4B/FT_6B FIXTURE LEG. SEE WIRING DETAILS ON SHEET E511. • CONDUIT SCHEDULE: FT_4B/FT 613: (1) 3/4" DEDICATED POWER • ELECTRICAL CONTRACTOR TO PROVIDE: CONDUIT AND J-BOX ABOVE CEILING FOR POWER POLE. ADJACENT PROVIDE POWER FROM PANEL TO CEILING MOUNTED J-BOX. LEAVE FLEX CONNECTION ASSEMBLY COILED AND TAPED AS REQUIRED UNTIL FIXTURE INSTALLATION. AFTER FIXTURE INSTALLATION TENANT ELECTRICAL CONTRACTOR TO PROVIDE APPROVED FLEX CONNECTION ASSEMBLY TO POWER SOURCE ROUTED THROUGH POWER POLE TO PRE -INSTALLED J-BOX IN FIXTURE. INSTALL FIXTURE MANUFACTURER SUPPLIED POWER STRIP AND FINAL CONNECTION TO POWER SOURCE. O CEILING MOUNTED RECEPTACLES ABOVE DFW/DFM FIXTURE. SEE WIRING DETAILS ON SHEET E511. • CONDUIT SCHEDULE: DFW/DFM: (1) 3/4" GENERAL POWER 2 DATA • ELECTRICAL CONTRACTOR TO PROVIDE: CONDUIT AND J-BOXES ABOVE CEILING AND INSTALL DUPLEX POWER RECEPTACLES INSIDE CEILING MOUNTED J-BOX FOR POWER, PROVIDE POWER CIRCUIT FROM PANEL TO RECEPTACLE. PROVIDE PULL STRING FROM TELEPHONE BOARD TO JBOX ABOVE CEILING FOR DATA CABLING AND RJ45 RECEPTACLE BY OWNE'RS VENDOR. • VENDOR TO PROVIDE: CAT5E CABLING FOR DATA AS REQUIRED TO PRE -INSTALLED BLANK DUPLEX BOX ABOVE CEILING. PROVIDE RJ45 JACK AS REQUIRED AND MAKE FINAL CONNECTIONS. D1 SHEET NOTES D4 ELECTRICAL SCHEMATIC LAYOUT - REFERENECE FOR TYPE AND LOCATION ONLY NOT ALL USED AT THIS LOCATION 1/8" = 1'-0" TAG DESCRIPTION POWER DATA TAG DESCRIPTION POWER DATA GENERAL NOTES: AC3_6 ACCESSORY PANEL W/USB 20A -- DWJ DISPLAY WALL J 20A -- DUPLEX RECEPTACLE F ELECTRICAL SCHEMATIC LAYOUT IS FOR LAYOUT / REFERENCE ONLY. ARCHITECT IS 20A DUPLEX RECEPTACLE AC3_7 ACCESSORY PANEL W/USB 20A -- DWK DISPLAY WALL K 20A -- NOT RESPONSIBLE FOR ELECTRICAL DESIGN OR ENGINEERING. A. VERIFY POSSIBLE RE -USE OF EXISTING SALES AREA CIRCUITS WHERE POSSIBLE & REBALANCE PANEL AS REQUIRED. 18" A.F.F. U.N.O. AC3_8 ACCESSORY PANEL W/USB 20A -- DWL DISPLAY WALL L 20A -- AC3_9 ACCESSORY PANEL W/USB 20A -- DWM DISPLAY WALL M 20A -- B. ALL WORK SHALL COMPLY WITH THE CURRENTLY ADOPTED CODES, ORDINANCES, AND AMENDMENTS. C. ALL EQUIPMENT SHALL BE LISTED BY A RECOGNIZED TESTING LAB (i.e. U.L., JO JUNCTION BOX O AC3 10 - ACCESSORY PANEL W/USB 20A -- DWN DISPLAY WALL N 20A __ AC3_11 ACCESSORY PANEL W/USB 20A -- DWP DISPLAY WALL P 20A -- ETC.) BFM 65 BRAND FOCAL MONITOR - 65" 20A 2 FT 4B FEATURE TABLE - 4'-0" - METAL 20A __ - - D. PROVIDE PLENUM RATED WIRING WHERE REQUIRED. COMPLY WITH NEC FOURPLEX RECEPTACLE BFM_65NS BRAND FOCAL MONITOR - 65" 20A 2 FT_6B FEATURE TABLE - 6'-0" - METAL 20A -- 300.22. E. PROPERLY GROUND RECEPTACLES, BOXES AND COVER PLATES INSTALLED IN 20A FOURPLEX RECEPTACLE 18" A.F.F. U.N.O. F BFM_82 BRAND FOCAL MONITOR - 82" 20A 2 FT FEATURE TABLE - MULTI TIER 20A __ -MT FIXTURES PER NEC 250.146 AND 406. BFM_82NS BRAND FOCAL MONITOR - 82" 20A 2 LB1 LED ILLUMINATED FRAME 20A -- F. NO BX, AC OR ROMEX TYPE WIRING ALLOWED. G. ALL LOW VOLTAGE WIRING TO BE IN CONDUIT UNLESS OTHERWISE APPROVED SINGLE RJ45 JACK W/ CAT5e WIRE xi CT-4 CONSULTATION TABLE - 4 SEATS 20A 4 SC-1 SINGLE SERVICE COUNTER 20A 4 + 2 FUTURE BY AUTHORITY HAVING JURISDICTION. °"E A DUPLEX RJ45 JACK W/ 2 CAT5e WIRES CT-6 CONSULTATION TABLE - 6 SEATS 20A 4 SC-1A SINGLE SERVICE COUNTER 20A 4 + 2 FUTURE CONTRACTOR NOTES: 1) GC SHALL CERTIFY / EXAMINE EXISTING CIRCUITS ON EXISTING ELECTRICAL X2 TELEPHONE/DATA OUTLET °'" °`� X2 L[ QUADPLEX RJ45 JACK W/ 4 CAT5e WIRES DFM DIGITAL FRONT WINDOW - 6" 20A 2 SC-2 DOUBLE SERVICE COUNTER 20A 8 + 4 FUTURE DFM - F DIGITAL FRONT WINDOW - 6" FREESTANDING 20A 2 SC PRT - MULTI -FUNCTION PRINTER CABINET 20A 2 PANELS TO DETERMINE IF EXISTING ELECTRICAL PANEL RATED LOAD (SIZE) IS SUFFICIENT FOR NEW OUTLET / LIGHTING LOADS. 2) IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE AND PAY FOR ALL DESIGN, APPLICATIONS, PLAN REVIEW, AND PERMITS RELATED TO ELECTRICAL SCOPE OF WORK, AS REQUIRED BY THE AUTHORITY HAVING /X4 �� of OVERHEAD AP CABLEING DFW DIGITAL FRONT WINDOW - 8" 20A 2 SW SYSTEM WALL PANEL - 47 1/4" 20A -- DFW F DIGITAL FRONT WINDOW - 8" FREESTANDING 20A 2 WB_4 WALL BAY - 4 FEET 20A -- ® CEILING MOUNTED DUPLEX RECEPTACLE RECEPTACLE FOR SHOW WINDOW LIGHTING, IF NOT EXISTING. COLOR TO MATCH CEILING. JUNCTION BOX MOUNTING AND CONDUIT POLE JUNCTION BOX AND CONDUIT MOUNTING POLE DS DIGITAL SIGNAGE 20A 2 WB-6 WALL BAY - 6 FEET 20A -- DS R DIGITAL SIGNAGE - WITH REMO 20A 2 WB 8 WALL BAY - 8 FEET 20A -- - - JURISDICTION. BY E.C. BY E.C. WB2_4 2_4M WALL BAY 20A -- NOTE: RELOCATE ALL FIRE STROBES, THERMOSTATS AND OTHER WALL MOUNTED DEVICES AS PER LOCAL CODE AS REQUIRED PER NEW FIXTURE LAYOUT. 120V MC CAT5e CABLE CABLE BY VENDOR BY E.C. 120V MC CABLE BY E.C. ® POWER MAST JUNCTION BOXAND CONDUIT COORDINATE WITH PROJECT MANAGER/ARCHITECT MOUNTING POLE LAY -IN CEILING POLE POWER OEER ❑ LAY -IN CEILING POWPOLE ER ❑8 Al FIXTURE POWER & DATA REQUIREMENTS SUMMARY A6 GENERAL NOTES A8 SHEET SYMBOLS NOTE: NOT ALL FIXTURES MAY BE USED AT THIS LOCATION NOT ALL USED AT THIS LOCATION Project Owner: Consultant: OPTIMUS TECHNICAL, LLC 6250 MANTEO DRIVE DUBLIN, OHIO 43016 PHONE (614) 843-1831 Copyright Protected 2017 Project Address: SAP #511D 7333 GALL BLVD SITE:7335 ZEPHYRHILLS, FL 33541 No. Date Description Sheet Title: ELECTRICAL PLAN ,`��u �oserrrrr ``% opPNIEL �1'9li��� C E tt � �. ��, "o No 78049 S %1�- '; STATE O F% .. .,���ss� ry ❑\x .0 3�1 IIIi,111 DWG. DATE: 01-19-17 REVIEWED BY: AM / AM PROJECT NUMBER: TMO 550 TEMPLATE TYPE: XX SHEET: E101 ICI■ milam.lug amVV illimm., � J uuj l mu Proiect Owner: G1 NOT USED D7 ELECTRICAL CONTRACTOR TO PROVIDE CONDUIT AND J-BOXES ABOVE CEILING FOR POWER POLE: • (1) 3/4" CONDUIT FOR DEDICATED POWER • (1) 3/4" CONDUIT FOR GENERAL POWER • (2) HUBBELL-RACO 674 HANDY BOX (2"x4", 2-1/8"D) • 10 DATA + 4 FUTURE • PROVIDE PULL STRING FROM TELEPHONE BOARD TO PRE -INSTALLED BLANK BOXES INSIDE FIXTURE FOR DATA CABLING BY OWNER'S VENDOR --,-,-----I,T--------�--_� xz I II III I II J'X2 X2 Xz I I I III 8 xz II II III I II II I II III I X2 II --------- IL--------- --- �mm I *0 G5 SC-2 SECTION ACCESSIBLE COUNTERTOP AT 34" MAX. A. F. F. G7 NOT USED D1 SC-2 + ADA D7 SC_2 + ADA 1/2" = 1'-0" PLAN VIEW 1/2" = 1'-0" 1 SECTION VIEW A7 ELECTRICAL CONTRACTOR TO PROVIDE CONDUIT AND J-BOXES ABOVE CEILING FOR POWER POLE: • (1) 3/4" CONDUIT FOR DEDICATED POWER • (1) 3/4" CONDUIT FOR GENERAL POWER • (2) HUBBELL-RACO 674 HANDY BOX (2"x4", 2-1/8"D) • 12 DATA + 4 FUTURE • PROVIDE PULL STRING FROM TELEPHONE BOARD TO PRE -INSTALLED BLANK BOXES INSIDE FIXTURE FOR DATA CABLING BY OWNER'S VENDOR G5 Tr nr_ X zz I II III II II II I II III 4 5 II Xz I II III 7 8 xz 11 II I II III I II -I� ---�-- -- -- ----- hr -- --I x2 -Ifi II I II III I XZ II Lm 1O WD-1 OR HARD FLOORING, TYP. OPOWER POLE. OELECTRICAL CONTRACTOR TO PROVIDE CONDUIT AND J-BOXES ABOVE CEILING FOR POWER POLE 4O ELECTRICAL CONTRACTOR TO INSTALL POWER RECEPTACLES IN PRE -INSTALLED BLANK QUADPLEX BOXES INSIDE FIXTURE, PROVIDE POWER CIRCUIT FROM PANEL TO RECEPTACLES AND PROVIDE APPROVED FLEX CONNECTION ASSEMBLY TO POWER SOURCE AFTER FIXTURE INSTALLATION. ODEDICATED POWER. OGENERAL POWER. OELECTRICAL CONTRACTOR TO PROVIDE PULL STRING FROM TELEPHONE BOARD TO PRE -INSTALLED BLANK BOXES INSIDE FIXTURE FOR CAT5E DATA CABLING AND RJ45 JACKS BY OWNER'S VENDOR. OOWNER'S VENDOR TO PROVIDE CAT5E DATA CABLING, RJ45 JACKS AND PLASTIC GROMMET TO FIT 3/4" KNOCK OUTS IN PRE -INSTALLED BLANK DUPLEX BOXES INSIDE FIXTURE AS REQ'D. ROUTE CABLING THROUGH CASEWORK AND MAKE CONNECTIONS TO RJ45 JACKS, TYP. G11 SHEET NOTES t O 0 0 ®® 7 8 O O 7 8 ®® 0 O 0 0 O O 4 5 O 4 5 o 0 0 4 6 tl e° .4 •e d'a� a �'° ° a Al SC 2 + SC PRT A7 SC-2 + SC PRT 112" = 1'-0" PLAN VIEW 1/2" _=1'-0'_1 SECTION VIEW )P Consultant: OPTIMUS TECHNICAL, LLC 6250 MANTEO DRIVE DUBLIN, OHIO 43016 PHONE (614) 843-1831 Copyright Protected 2017 Project Address: SAP # 511 D 7333 GALL BLVD SITE-7335 ZEPHYRHILLS, FL 33541 Sheet Title: FIXTURE FEED WIRING DETAIL ,,,,1,1a,1s,,,,. ,o��� V p N I E L jV i �•. V.•• No 78049 -'A STATE OF t4✓� .0 :l: i4�; S,ON A�; �i "V 7� DRAWN BY: JN DWG. DATE: 01-19-17 REVIEWED BY: AM / AM PROJECT NUMBER: TMO 550 TEMPLATE TYPE: XX SHEET: E501 III'nl�'11!Y �7II11��'IIIIII�IIRItI If�1�9 1 '41a,lll'I MIL I�� �I' II'fl 'I� _ If 61"JI1 rP I'!�111'gI "jI OWD-1 OR HARD FLOORING, TYP. OPOWER POLE. ELECTRICAL CONTRACTOR TO PROVIDE CONDUIT AND J-BOXES ABOVE CEILING FOR POWER POLE. OPRE -INSTALLED J-BOX BY FIXTURE MANUFACTURER FOR CONNECTION TO POWER SOURCE BY ELECTRICAL CONTRACTOR AFTER FIXTURE INSTALLATION. OELECTRICAL CONTRACTOR TO INSTALL POWER RECEPTACLES IN PRE -INSTALLED BLANK DUPLEX BOX INSIDE FIXTURE, PROVIDE POWER CIRCUIT FROM PANEL TO RECEPTACLES AND PROVIDE APPROVED FLEX CONNECTION ASSEMBLY TO POWER SOURCE AFTER FIXTURE INSTALLATION. ELECTRICAL CONTRACTOR TO INSTALL OWNER SUPPLIED POWER STRIP AND FINAL CONNECTION TO POWER SOURCE AFTER FIXTURE INSTALLATION. I G1 NOT USED � G5 NOT USED � G7 � NOT USED � G11 � FT_46/FT_6B KEY NOTES I PLAN VIEW ELECTRICAL CONTRACTOR TO PROVIDE CONDUIT AND J-BOX ABOVE CEILING FOR POWER POLE: • (1) 3/4" CONDUIT FOR POWER • (1) APPROVED FLEX CONDUIT CONNECTION ASSEMBLY TO J-BOX FOR POWER G5 4 E511 .I 2 13 G7 E511 I D1 FT_4B (FEATURE TABLE) D5 FT_413 (FEATURE TABLE) D7 FT_4B (FEATURE TABLE) 1" = V-0" PLAN VIEW 1" = V-0" SECTION VIEW 1" = V-0" SECTION VIEW • ELECTRICAL CONTRACTOR TO PROVIDE CONDUIT ABOVE CEILING TO JBOXES AND CEILING MOUNTED RECEPTACLES. • (1) 3/4" CONDUIT ABOVE CEILING FOR POWER • (1) 3/4" CONDUIT ABOVE CEILING FOR DATA • PROVIDE PULL STRING FROM PANEL FOR FUTURE DATA CABLING BY OWNER'S VENDOR • (2) HUBBELL-RACO 674 HANDY BOX (4"x2", DEPTH: 2-1/8") W/ COVER PLATES 1O CEILING TYPE VARIES. 2O ALUMINUM EXTRUDED FIXTURE BY OWNERS VENDOR. EXACT HEIGHT CUT IN FIELD TO MATCH CEILING HEIGHT. O ELECTRICAL CONTRACTOR TO PROVIDE CONDUIT ABOVE CEILING TO J-BOXES AND INSTALL DUPLEX POWER RECEPTACLES INSIDE CEILING MOUNTED J-BOX FOR POWER. PROVIDE POWER CIRCUIT FROM PANEL TO RECEPTACLE. PROVIDE PULL STRING FROM TELEPHONE BOARD TO JBOX ABOVE CEILING FOR DATA CABLING AND RJ45 RECEPTACLE BY OWNERS VENDOR. 4O OWNER'S VENDOR TO PROVIDE CAT5E CABLING FOR DATA AS REQ'D FROM J-BOX ABOVE CEILING. THRU FLEX CONDUIT TO SURFACE MOUNTED J-BOX AND INTO FIXTURE AFTER FIXTURE INSTALLATION. PROVIDE RJ45 JACK AS REQ'D AND PLASTIC GROMMET TO FIT 3/4" TRADE SIZE KO AND MAKE CONNECTIONS TO PRE -INSTALLED BLANK DUPLEX BOX. I A4 � DFW/DFM (DIGITAL FRONT WINDOW/MALL) A7 DFW/DFM KEY NOTES � A10 � DFW/DFM (DIGITAL FRONT WINDOW/MALL) I 1 1" = V-0" I PLAN VIEW I I 1 1" = V-0" I SECTION VIEW Project Owner: Consultant: OPTIMUS TECHNICAL, LLC 6250 MANTEO DRIVE DUBLIN, OHIO 43016 PHONE (614) 843-1831 Copyright Protected 2017 Project Address: SAP # 511 D 7333 GALL BLVD SITE:7335 ZEPHYRHILLS, FL 33541 No. Date Description Sheet Title: FIXTURE FEED WIRING DETAIL ,,"I%JJ11111r1'"e' %0 ,0NNIEL% M 'P.-i No 78049 to 4 � � 0 -O + � e 4u • STATE OF • .� eo���5 �O IN A DRAWN DWG. DATE: • REVIEWED BY: c PROJECT• 550 CI • A '4=01:� E511 11111111111111 RII'iRl!I�Alll'I�I61 �111ILII'I'll!'il l Iu I_IIII''IU IIII,II�I I II !III, II I I !" �191!!IIII I RIIII III't IImlillli LIII EXTERIOR E 1/4" = 1'-01, ADJACENT' TENANT HEADER BEAM ACP-1 9'-11" A.F.F. �Ej____ —�_ �__ = —�__ _ -- —1= B= _ _ =—e--= B =__ - - - - Ti 97 I I /10I I / I I I 7r /1 Ii iIIT] -- i i r - - -- - - I---7 I IF-- -�—— ----, BACK OF I I' IJI----- II II I I II 'i I I li HOUSE N.I.C. I' I' �m LED-T \ _�---- --- �— --- ---- ---- II H I I --- --- 1 II N — SALES I I o AIII I II LDD-TH REA- - - - - L - I TOILET I , 3'-8" TYP. _ _ P - ROOM \ W W W W ❑ ❑ ❑ ❑ ❑ N. I. C. u�11 ❑ ❑ ❑ °I i i w w w w w J �- - � J J ao - _ �__ _ _ _ _ _ _ _ - -_- START ACP-1 LAYOUT ACP-1 !I_ INSTALL LIGHTING DIGITAL MONITOR DISPLAY FIXTURE. G.C. TO 9'-11"A.F.F. TRACKS 3'-8" FROM PROVIDE PLYWOOD BLOCKING ATTACHED WALL (TYP) TO STRUCTURE OR STUDS ABOVE CEILING. SEE E1/A501. FIXTURE INSTALLER TO PROVIDE ATTACHMENT HARDWARE TO SECURE DIGITAL MONITOR DISPLAY FIXTURE TO BLOCKING FOR STABILIZATION. — NOTE: CONTRACTOR SHALL USE/REUSE EXISTING CIRCUITS FOR LIGHTING, POWER AND SIGNAGE. VERIFY LIGHTING CONTROLS FOR REUSE. CONTRACTOR TO VERIFY CIRCUIT INTEGRITY AND CAPACITY, PROVIDE NEW ONLY AS NEEDED. GENERAL & RCP NOTES: 1.REFER SPECIFICATION SHEET FOR FINISHES 2. ALL DIMENSIONS TO BE FIELD VERIFIED BY GC. 3. THE REFERENCE HEIGHTS INDICATED ON PLAN ARE FROM APPROXIMATE FINISH FLOOR (A.F.F.) 4. GENERAL CONTRACTOR TO COORDINATE SALES FLOOR LIGHTING WITH APPROVED INTERIOR DECOR PLANS. 5. CONTRACTOR SHALL VERIFY FIXTURE QUANTITIES AND ALSO MAKE PROPER ADJUSTMENTS FOR ANY CHANGES IN PLAN DUE TO ADDITIONAL REQUIREMENTS, LOCAL CODES, ETC. 6. ALL FIXTURES SHALL BE LOCATED IN CENTER OF CEILING TILES UNLESS OTHERWISE NOTED. 7. ALL FIXTURES MARKED 'EM' (EMERGENCY) SHALL HAVE (2) LAMPS ON AN UNSWITCHED LEG OF THE ROOM LIGHTING CIRCUIT WITH AN EMERGENCY BATTERY INVERTER BALLAST. 8. ALL EMERGENCY CIRCUITS SERVING NIGHT / EMERGENCY LIGHTING SHALL BE MINIMUM #10 AWG CONDUCTORS FOR THE ENTIRE CIRCUIT ON 120 VOLT CIRCUITS OVER 100 FEET AND 277 VOLT CIRCUITS OVER 200 FEET. 9. PER SECTION 1013.6.3, 2015 IBC, EXIT SIGNS MUST BE PROVIDED WITH BACKUP POWER FOR A DURATION OF NOT LESS THAN 90 MINUTES IN THE EVENT OF PRIMARY POWER LOSS. 10.TIE ALL ELECTRICAL LIGHTING ETC. TO EXISTING PANELS. PANELS TO BE BALANCED. NEW SWITCHES TO BE INSTALLED IN EXISTING SWITCH BANK AREA. GENERAL CONTRACTOR TO VERIFY. 11. CONTRACTOR SHALL SUPPLY AND INSTALL ALL MATERIALS TO PROVIDE A COMPLETE INSTALLATION IN ACCORDANCE WITH THE CURRENT EDITION OF THE N.E.C. AND ALL STATE AND LOCAL CODES AND AMENDMENTS. ADJACENT TENANT SYMBOL DESCRIPTION E SINGLE HEAD ADJUSTABLE SINGLE HEAD ADJUSTABLE FOR EMERGENCY OPERATION 0701 DUAL HEAD ADJUSTABLE DUAL HEAD ADJUSTABLE FOR 070 EMERGENCY OPERATION O O O TRIPLE HEAD ADJUSTABLE O O O TRIPLE HEAD ADJUSTABLE FOR EMERGENCY OPERATION RECESSED 2'x2' RECESSED 2'x2' FOR EMERGENCY OPERATION * SEE G1/A601 FOR T-MOBILE PREFERRED LIGHTING SCHEDULE AND D1/A601 FOR ALTERNATE LIGHTING SCHEDULE A9 SHEET SYMBOLS NOT ALL USED AT THIS LOCATION SEE SHEET A601 FOR SCHEDULES G.C. TO FIELD VERIFY ALL CEILING HEIGHTS AND NOTIFY ARCHITECTS IMMEDIATELY OF ANY DISCREPANCIES OR UNFORESEEN ITEMS NOT SHOWN ON DRAWINGS. SYMBOL I DESCRIPTION SURFACE MOUNTED 2'x2' SURFACE MOUNTED 2'x2' FOR EMERGENCY OPERATION PENDANT MOUNTED 2'x2' P PENDANT MOUNTED 2'x2' FOR EMERGENCY OPERATION CEILING MOUNTED VENTILATION FAN WITH LED LIGHT MOTION SENSOR. EXIT SIGN WITH BATTERY BACKUP EMERGENCY LIGHTING D TRACK LIGHTING ACP-1 CEILING SYSTEM / FINISH 10'-6" A.F.F. CEILING HEIGHT Project Owner: Consultant: OPTIMUS TECHNICAL, LLC 6250 MANTEO DRIVE DUBLIN, OHIO 43016 PHONE (614) S43-1S31 Copyright Protected 2017 Project Address: SAP #511D 7333 GALL BLVD SITE:7335 ZEPHYRHILLS, FL 33541 No. Date Description _ Sheet Title: LIGHTING PLAN PNIEL 0 : No 78049 ; (P * :(r_ ;W- • STATE. OF 414 DRAWN BY: JN DWG. DATE: 01-19-17 REVIEWED BY: AM / AM PROJECT NUMBER: TMO 550 TEMPLATE TYPE: XX SHEET: E512