HomeMy WebLinkAbout7519 Gall Blvd (2)40l=III Ih mii 111E I.:���-11 ••r � JittiWi4�J._. L1.i4A= j...a . li.. _ 1. � _ GENERAL NOTES 1. ALL APPLICABLE PERMITS SHALL BE OBTAINED PRIOR TO STARTING WORK. 2. WORK SHALL COMPLY WITH ALL APPLICABLE CODES. 3. RECORD DRAWINGS (AS -BUILT) SHALL BE ACCURATELY MAINTAINED AND FORWARDED TO THE APPROPRIATE PARTY UPON COMPLETION OF PROJECT. 4. POWER (120VAC) TO ALL FIRE ALARM AND SECURITY PANELS SHALL BE SUPPLIED FROM DEDICATED, UNSWITCHED AND CLEARLY IDENTIFIABLE SOURCES. 5. ALL DOORS WHICH ARE CONTROLLED BY ELECTRONIC LOCKING DEVICES SHALL BE CONFIGURED TO MEET ALL CODES. 6. ALL DEVICES EITHER INSTALLED WITHIN THE SCOPE OF THIS PROJECT OR EFFECTED BY THIS PROJECT SHALL BE TESTED. 7. ALL CABLE SHALL BE RATED FOR THE ENVIRONMENT IN WHICH IT IS INSTALLED. 8. ALL WORK SHALL BE PERFORMED IN A PROFESSIONAL MANNER. 9. AREAS EFFECTED BY THE SCOPE OF THIS PROJECT SHALL BE KEPT CLEAN AND TRASH REMOVED DAILY. QTY. 1 1 2 2 1 IN QTY. 1 4 QTY. 1 1 28 QTY. 1 1 1 2 0 2 12 2 0 QTY. 3 1 1 2 0 RIONICS COVER SHEET - NOT ALL DEVICES DISPLAYED ON THIS LEGEND APPEAR ON DRAWINGS - INTRUSION (BURGLAR) ALARM (ES) DEVICES SYMBOL DEVICE DESCRIPTION © BURGLAR ALARM CONTROL PANEL FK_Pj KEYPAD (ALPHANUMERIC) USE 18-04 OAS Cable ❑O SIREN/SOUNDER / EXTERIOR HORN/STROBE ALARM NOTIFICATION USE 18-04 OAS Cable Oc DOOR CONTACT MOTION DETECTOR (Wide angle) 0 WIRELESS REPEATER ACCESS CONTROL (ES) DEVICES SYMBOL DEVICE DESCRIPTION Fc-Ac-P-1 _ ACCESS CONTROL PANEL rK-1 KEYPAD USE 18-04 OAS & 18-04 OAS DIRECT BURIAL Cable Oxx GATE OVERIDE SWITCH BACKGROUND MUSIC (BM) DEVICES SYMBOL DEVICE DESCRIPTION AMP 1 60 WATT AMPLIFIER WITH AM/FM/CD WITH AUX INPUT AND PAGING F-MI-cl DESK TOP MICROPHONE OOa CM SWAY SPEAKER, CEILING MOUNTED USE 18-02 OAS Cable CLOSED CIRCUIT TELEVISION (ES) DEVICES SYMBOL DEVICE DESCRIPTION NVR NETWORK VIDEO RECORDER FP-o-El POE NETWORK SWITCH - PORT AMOUNT AS NOTED uPs UNINTERRUPTED POWER SUPPLY / BATTERY BACK UP o CCTV MONITOR •" CAMERA (FIXED) USE 24-4P C5E Cable ��Dual CAMERA (Dual Lens) USE 24-4P C5E Cable OMD CAMERA (MINI -DOME) (Vari = VARIFOCAL LENS) USE 24-4P C5E Cable Q 120VAC/20A DEDICATED UNSWITCHED DUPLEX RECEPTACLE (BY OTHER) wAP WIRELESS ACCESS POINT (POC TO CUSTOMER PROVIDED WAP) CABLING PART # DEVICE DESCRIPTION 414104 18-02 OAS STIR CMR Org Stp (Background Music) 1000FT BOX 414302 18-04 OAS STIR CMR Blu Stp (Access)(Intrusion) 1000FT BOX 71431 CVNQ 18-04 OAS STIR DB TC Quad (Access DB) 1000FT BOX 8665610-10 24-4P UNS SOL CMR C5E Wht Jkt (CCTV) 1000FT BOX 665610-110DB 24-4P UNS SOL PE C5E Blk DB (CCTV DB) 1000FT BOX NOTE: DB = DIRECT BURIAL CABLE SHEET NAMING CONVENTION SHEET SHEET DESCRIPTION CS 1 .01 COVER SHEET(S) & NOTES ES ELECTRONIC SECURITY SYSTEMS FA - FIRE ALARM SYSTEMS 1.01 FLOOR PLANS / DEVICE LOCATION DRAWINGS 2.01 RISER DIAGRAM DRAWINGS 3.01 PRODUCT TYPICAL DRAWINGS 4.01 DEVICE DETAIL DRAWINGS 5.01 POWER CALCULATION SHEETS 6.01 PRODUCT DATA SHEETS 7.01 SEQUENCE OF OPERATIONS MATRIX & GRAPHIC ANNUNCIATOR IDENTIFIERS TYPE DEVICE DESCRIPTION RNx xxxx POINT OF PROTECTION IDENTIFIER / TYPE REFERENCE 0P1-3.2 POWER SUPPLY #1 / CIRCUIT 3 / SECOND DEVICE IN LINE 001-003 LOOP #1 / DEVICE #3 CABLE ID - SEE "CABLE LEGEND" FOR MORE INFORMATION A,B,c A-1.0 SHEET ID - SHEET DETAIL "A", "B", "C" / SHEET # FA-1.01 CABLE LEGEND ID AWG COND SHIELD CLASS* A 18 2 N FPLP B C 18 18 2 4 Y N FPLP FPLP D 16 2 N FPLP E 16 2 Y FPLP F 16 4 N FPLP G 14 2 N FPLP H 14 4 N FPLP 1 12 2 N FPLP J 12 4 N FPLP K 24 2 Y CL2P L 22 2 N CL2P M 22 4 N CL2P N 22 4 Y CL2P 0 22 4 Y** CL2P P 22 10 N CL2P Q 18 2 N CL2P R 18 2 Y CL2P S 18 4 N CL2P T 18 4 Y CL2P U 18 6 Y CL2P V 18 8 Y CL2P * SEE GENERAL NOTE #7 SHEET INDEX ID AWG COND SHIELD CLASS* W 18 10 N CL2P Z 18 12 Y CL2P Y 16 2 N CL2P Z 16 2 Y CL2P AA 16 4 N CL2P BB 16 4 Y** CL2P CC 16/19 4 N CL2P DID 14 2 N CL2P EE 14 1 N CL2 FF RG59 N CL2P GG RG59 & 18/2 N CL2P HH RG6 N CL2P II CAT5e N CL2P JJ CAT6 N CL2P KK PATCH -CABLE COPPER LL 62.5/125um MULTI MODE MM 9/125um SINGLE MODE NN PATCH -CABLE FIBER-OPTIC 00 PP QQ RR ** 2 PAIR - EACH PAIR WITH INDIVIDUAL SHIELD SHEET DESCRIPTION CS1.01 COVER SHEET, LEGENDS AND GENERAL NOTES SEC1.01 SITE SECURITY PLAN SEC1.02 FIRST FLOOR PLAN SEC2.01 SECOND FLOOR SECURITY PLAN SEC3.01 THIRD FLOOR SECURITY PLAN aid z °d A9 U T U. N coo o - oQ � �J 3:�r QU< z 1�5 `i_� 5lq Y� ATTENTION: THESE DRAWINGS MAY CONTAIN CONFIDENTIAL INFORMATION AND SHOULD NOT BE DISTRIBUTED DRAWING ACCEPTANCE: IT IS THE RESPONSIBILITY OF THE LOCAL Rionics SALES & SERVICE OFFICE (SSO) TO REVIEW THE CONTENT OF THESE DRAWINGS FOR ACCURACY AND COMPLIANCE WITH LOCAL AND STATE CODES PRIOR TO RELEASING THEM TO THE FIELD. RECORD DRAWINGS: ALL WORK PERFORMED IN THE FIELD SHALL BE ACCURATELY RECORDED ON THESE DRAWINGS AND RETURNED TO THE MAIN OFFICE CAD DEPARTMENT AT: RIONICS, LLC 2700 BRASELTON HWY. STE# 10-388 DACULA, GA, 30019 ATTN: AS-BUILTS NICET REVIEW PERFORMED BY: NAME: SIGNATURE: NICET #: RELEASE / REVISION LOG NO. DATE INT. DESCRIPTION R k WnF Q CC C y 0 N 0 J � c _CDco �$ , a N CO co o�alev a if iWk 4. C O Al �ZaL. y J LL PROJECT NORTH 0 CUSTOMER Flagship General Contractor, LLC. Zephyrhills Self Storage 7519 Gall Boulevard Zephyrhills, FL 33541 DRAWN BY CHECKED BY RELEASE SL GJ SHEET TITLE Rionics COVER SHEET This design including specifications, drawings, and design concepts is the property of Rionics, LLC., and is furnished on a confidential basis, with the expressed understanding that it will not be sold, transfered, copied, or used to the detriment of Rionics without written permission. The recipient further agrees not to disclose the contents to any other party except for the specific purpose contracted for with Rionics. Rionics makes no representations as to the operability or accuracy of any systems, subsystems, assemblies, or other information contained herein unless specifically identified for Construction. DATE I REF 4/1/24 1 - SCALE SHEET AS NOTED CS-01 NOTES: 1. 7' X 4' X 3' CONCRETE OPERATOR MOUNTING PAD BY OTHERS. 2. GATE CANNOT HAVE OVERHEAD OBSTRUCTIONS. 3. EQUIPMENT TO LIFT GATES FROM DELIVERY TRUCK AND SET ON OR NEAR CONCRETE PADS WILL BE PROVIDED. 4. RECEPTACLES FOR DEBRIS REMOVAL BY OTHERS. 5. GATE MEETS UL325 STANDARDS. 6. GATE OPERATOR HAS BATTERY BACKUP. 7. 110VAC, 20AMP CIRCUIT REQUIRED PER OPERATOR BY OTHER. 8. ELECTRICAL SERVICE TO OPERATORS AND LOW VOLTAGE CONDUIT RACEWAY BY OTHERS. 9. OPERATOR, GATE AND FENCE TO BE A PART OF APPROVED SITE PLAN. 10. WALK GATE HANDLE HARDWARE BY OTHERS. I 120VAC UNSWITCHED OUTLET PROVIDED BY OTHER. SEE NOTE #YC SOS-12 FOR EMERGENCY VEHICLE ENTRY (PASCO COUNTY FIRE RESCUE) M 1.5" PVC CONDUIT / (FROM STRUCTURE TO / THE BACK OF THE / OPERATOR / / EXIT GATE - 2 24FT GATE, OPERATOR _L 0 0 / I� ("A.2 EXIT GATE DETAIL ES Scale: 1/8"=1' SOS-12 FOR EMERGENCY VEHICLE ENTRY (PASCO COUNTY FIRE RESCUE) ;1 1" PVC CONDUIT FROM GATE v OPERATOR TO GOOSENECK 03 04 I q SAFETY LOOP CTE ENTRY - 1 24FT GATE, 0 ftm� OP SEE NOTE #1 ;: 1 i SAFETY LOOP 1.5" PVC CONDUIT FROM 120VAC UNSWITCHED STRUCTURE TO THE BACK OUTLET PROVIDED BY OF THE OPERATOR OTHER. A.1 ES A ES ENTRY GATE DETAIL Scale: 1 /8"=1' ELECTRONIC SECURITY DEVICE LOCATIONS -SITE PLAN Scale: 1/16"=1' FOR CONSTRUCTION This design including specifications, drawings, and design concepts is the property of Rionics. LLC., and is furnished on a confidential basis, with the expressed understanding that it will not be sold, tronsfered, copied, or used to the detriment of Rionics without written permission. The recipient further agrees not to disclose the contents to any other party except for the specific purpose contracted for with Rionics. Rionics makes no representations as to the operability or accuracy of any systems, subsystems, assemblies, or other information contained herein unless specifically identified for Construction. SEE NOTE #1 20VAC JNSWITCHED )UTLET 'ROVIOEO BY )THER. ATTENTION: THESE DRAWINGS MAY CONTAIN CONFIDENTIAL INFORMATION AND SHOULD NOT BE DISTRIBUTED DRAWING ACCEPTANCE: IT IS THE RESPONSIBILITY OF THE LOCAL Rionics SALES & SERVICE OFFICE (SSO) TO REVIEW THE CONTENT OF THESE DRAWINGS FOR ACCURACY AND COMPLIANCE WITH LOCAL AND STATE CODES PRIOR TO RELEASING THEM TO THE FIELD. RECORD DRAWINGS: ALL WORK PERFORMED IN THE FIELD SHALL BE ACCURATELY RECORDED ON THESE DRAWINGS AND RETURNED TO THE MAIN OFFICE CAD DEPARTMENT AT: RIONICS, LLC 2700 BRASELTON HWY. STE# 10-388 DACULAI GA, 30019 ATTN: AS—BUILTS NICET REVIEW PERFORMED BY: NAME: SIGNATURE: NICET #: RELEASE / REVISION LOG NO. DATE INT. DESCRIPTION , , , , * I PROJECT NORTH n CUSTOMER Flagship General Contractor, LLC. Zephyrhills Self Storage 7519 Gall Boulevard Zephyrhills, FL 33541 DRAWN BY I CHECKED BY I RELEASE ' SL GJ SHEET TITLE SITE SECURITY PLAN DATE REF#/JOB# 4/1 /24 SCALE SHEET AS NOTED SEC-1.01 col C 06 xvtw�yvvRvv ,._ vyk.vv�vvavv�rw�vv7ero © IIIIIII �� u a� m © >n a�■■a a IIIIIII � o I i hI I I I I I I j C05 l l l l l l l I N01ns S CM SO4 �o CM S03 g r �01 CO2 © s a02 (N o EXACT MONITOR o PLACEMENT \ TBD ON SITE / Col O4 AMP C14 MIC • NVR ATTENTION: -- PoE THESE DRAWINGS MAY CONTAIN CONFIDENTIAL ❑� FU —PS1 16 INFORMATION AND SHOULD NOT BE DISTRIBUTED DRAWING ACCEPTANCE: • IT IS THE RESPONSIBILITY OF THE LOCAL Rionics SALES &SERVICE OFFICE (SSO) TO IP CM S02 REVIEW THE CONTENT OF THESE DRAWINGS g ■ FOR ACCURACY AND COMPLIANCE WITH LOCAL AND STATE CODES PRIOR TO RELEASING THEM TO THE FIELD. 16 PORT PoE SWITCH: RECORD DRAWINGS: • TERMINATE THE g FOLLOWING CAMERAS. ALL WORK PERFORMED IN THE FIELD SHALL BE C01 CO2, CO3, C04, ACCURATELY RECORDED ON THESE DRAWINGS , • C05, C06, C07, C08, AND RETURNED TO THE MAIN OFFICE CAD DEPARTMENT AT: C091 C 10, C11, C 12, C13, C14. ONE PORT RIONICS, LLC S05 S,o CM DEDICATED FOR THE 2700 BRASELTON HWY. STE# 10-388 DACULA, GA, 30019 S DES S S NVR. ATTN: AS—BUILTS ■ NICET REVIEW PERFORMED BY: NAME: SIGNATURE: NICET #: RELEASE / REVISION LOG NO. DATE INT. DESCRIPTION ' C13 • 0 • • • o • • • • w C12 pp= r U �� N eQo Z 4 O y 04 -V � O p� a` N o 44 M � CM S06 cc` 0. �Z m to y S07 Sj O C09 CM LL - (N) S08 S PROJECT NORTH _. 0 02 _ Clo II IIIIIIII li I IIIIIIII C08 � Illlllj C11 CUSTOMER DUAL DUAL Flagship General Contractor, LLC. Zephyrhills Self Storage 7519 Gall Boulevard Zephyrhills, FL 33541 DRAWN BY CHECKED BY RELEASE SL GJ SHEET TITLE A ELECTRONIC SECURITY DEVICE LOCATIONS - 1ST FLOOR FOR CONSTRUCTION FIRST FLOOR SECURITY PLAN ES Scale: 1/8°= 1' DATE REF#/JOB# 4/1 /24 SCALE SHEET r x understanding that will not be old t nsf red copied, or used to the detriment of Rionics without written permission. The recipient further agrees not to disclose the contents to an other except for the specific purpose contracted for with Rionics. Rionics makes no representations ae to the o operability or accuracy of an stems subsystems,s mbliea or other information This design including specifications, drawings, and design concepts is the property of Rionics, LLC., and is furnished on o confidential basis, with the expressed underota d g of it wi a ro e p d, p p g y partype p rpop ty cy y systems, assemblies, contained herein unless specifically identified for Construction. AS NOTED C r SEC-1 •02 LL,i iiil, a -�La u _ li - Li,4iia-_ i - — . _ �11 e,. _ _LiII.LII iisy wAim 0 W.j ELECTRONIC SECURITY DEVICE LOCATIONS - 2ND FLOOR FOR CONSTRUCTION Scale: 1 /8"=1' This design including specifications, drawings, and design concepts is the property of Rionics, LLC., and is furnished on a confidential basis, with the expressed understanding that it will not be cold, transfered, copied, or used to the detriment of Rionics without written permission. The recipient further agrees not to disclose the contents to any other party except for the specific purpose contracted for with Rionics. Rionics makes no representations as to the operability or accuracy of any systems, subsystems, assemblies, or other information contained herein unless specifically identified for Construction. ATTENTION: THESE DRAWINGS MAY CONTAIN CONFIDENTIAL INFORMATION AND SHOULD NOT BE DISTRIBUTED DRAWING ACCEPTANCE: IT IS THE RESPONSIBILITY OF THE LOCAL Rionics SALES & SERVICE OFFICE (SSO) TO REVIEW THE CONTENT OF THESE DRAWINGS FOR ACCURACY AND COMPLIANCE WITH LOCAL AND STATE CODES PRIOR TO RELEASING THEM TO THE FIELD. RECORD DRAWINGS: ALL WORK PERFORMED IN THE FIELD SHALL BE ACCURATELY RECORDED ON THESE DRAWINGS AND RETURNED TO THE MAIN OFFICE CAD DEPARTMENT AT: RIONICS, LLC 2700 BRASELTON HWY. STE# 10-388 DACULA, GA, 30019 ATTN: AS—BUILTS NICET REVIEW PERFORMED BY: NAME: SIGNATURE: NICET #: RELEASE / REVISION LOG � W �t9a•� MA O i O a�C+ W,A U., a m �c J PROJECT NORTH CUSTOMER Flagship General Contractor, LLC. Zephyrhills Self Storage 7519 Gall Boulevard Zephyrhills, FL 33541 DRAWN BY I CHECKED BY I RELEASE SGJ ' SHEET TITLE SECOND FLOOR SECURITY PLAN DATE REF#/JOB# 4/1 /24 " SCALE SHEET SEC-2. 1 AS NOTED 0 A ES ELECTRONIC SECURITY DEVICE LOCATIONS - 3RD FLOOR FOR CONSTRUCTION Scale: 1 /8"=1' ATTENTION: THESE DRAWINGS MAY CONTAIN CONFIDENTIAL INFORMATION AND SHOULD NOT BE DISTRIBUTED DRAWING ACCEPTANCE: IT IS THE RESPONSIBILITY OF THE LOCAL Rionics SALES & SERVICE OFFICE (SSO) TO REVIEW THE CONTENT OF THESE DRAWINGS FOR ACCURACY AND COMPLIANCE WITH LOCAL AND STATE CODES PRIOR TO RELEASING THEM TO THE FIELD. RECORD DRAWINGS: ALL WORK PERFORMED IN THE FIELD SHALL BE ACCURATELY RECORDED ON THESE DRAWINGS AND RETURNED TO THE MAIN OFFICE CAD DEPARTMENT AT: RIONICS, LLC 2700 BRASELTON HWY. STE# 10-388 DACULA, GA, 30019 ATTN: AS—BUILTS NICET REVIEW PERFORMED BY: NAME: SIGNATURE: NICET #: RELEASE / REVISION LOG PROJECT NORTH c CUSTOMER Flagship General Contractor, LLC. Zephyrhills Self Storage 7519 Gall Boulevard Zephyrhills, FL 33541 DRAWN BY CHECKED BY RELEASE SL GJ SHEET TITLE THIRD FLOOR SECURITY PLAN This design including specifications, drawings, and design concepts is the property of Rionics, LLC., and is furnished on a confidential basis, with the expressed understanding that it will not be sold, transfored, copied, or used to the detriment of Rionics without written permission. The recipient further agrees not to disclose the contents to any other porty except for the specific purpose contracted for with Rionics. Rionics makes no representations as to the operability or accuracy of any systems, subsystems, assemblies, or other information contained herein unless specifically identified for Construction. DATE REF#/JOB# 4/1 /24 SCALE SHEET AS NOTED SHEET.