Loading...
HomeMy WebLinkAbout38422-38646 Valley OaksLEGEND/CATALOG NUMBERS SMOKE DETECTOR, PHOTOELECTRIC TYPE VISUAL INDICATING APPLIANCE L�J [�E AUDIO/VISUAL INDICATING APPLIANCE Ms MINI SOUNDER i MINI SOUNDER WITH STROBE ❑E MANUAL PULL STATION FFA`C_P1 ADDRESSIBLE FIRE ALARM CONTROL PANEL AA FIRE ALARM ANNUNCIATOR PANEL F-M-M-1 MONITOR MODULE ®M CONTROL MODULE S MINI HORN/SMOKE DETECTOR (PHOTOELECTRIC) FE-01-1 END OF LINE RESISTOR 0 HEAT DETECTOR a SPRINKLER SYSTEM FLOW SWITCH, NOT BY FIRE ALARM CONTRACTOR SPRINKLER SYSTEM VALVE TAMPER SWITCH, NOT BY FIRE ALARM CONTRACTOR L C Please be advised ft review of plans submitted is a Glremy review b assist the contractor in compliance with applicable fie safety codes. This review is not intended to be a final approval of the submitted plans. It is the contractor's sole responsibility to ensure that the plans are in complete compaance with all applicable NFPA codes and local ordinmces. In the event that further examination or site inspection reveals areas of non-compliance, it shall be the contractor's sob responsibility, at their sole expense to bring those areas in compliance. The City assumes no responsibility for the contractor's failure to be in compliance with all applicable WFPA Codes and local ordinances. ILMMITfEI2 PIL.ANfS) 1tK' VE BEEN RFMEWEM 3Y ZEPHYRHI L FIR4MARS'S OFFICE Date: COMMUNITY BUILDING/BUILDING TYPE 1 FIRE LITE 9200 TO SHUNT TRIP - CIRCUIT BREAKER OF ELEVATOR POWER CKT. ELEVATOR MACHINE B ROOM TOP OF ELEVATOR SHAFT WARNING LIGHT ACTIVATION BY MACHINE ROOM SMOKE DETECTOR (TYPICAL) ELEVATOR PIT �Ibl 2ND. FLOOR Tom/ 1 ST. FLOOR ._@WARNING LIGHT �J"DO NOT USE ELEVATOR" FIRE ALARM FLOOR ZONE FIRE ALARM FLOOR ZONE FIRE ALARM DETAIL FOR ELEVATOR FULLY SPRINKLED BUILDING NO SCALE NOTES: 1. DERIVE POWER FOR FLASHING WARNING LIGHT FROM VISUAL ALARM CIRCUIT IN FIRE ALARM CONTROL PANEL. 2. COORDINATE HEAT DETECTOR LOCATIONS WITH SPRINKLERS. DETECTORS SHALL BE LOCATED WITHIN 24" OF EACH SPRINKLER HEAD. 3. INITIATION OF ELEVATOR LOBBY, TOP OF SHAFT, OR MACHINE ROOM SMOKE DETECTOR LOOP SHALL PLACE ELEVATOR CONTROL INTO PHASE 1 RECALL MODE & RETURN ELEVATOR TO DESIGNATED SAFE PLACE. LEGEND 3A SMOKE DETECTOR(S) AND 135 DEG F FIXED TEMPERATURE HEAT DETECTOR(S) LOCATED IN ELEVATOR MACHINE ROOM. OB SHUNT TRIP CONTACT LOCATED IN HEAT DETECTOR TO SHUNT TRIP POWER TO ELEVATOR UPON ACTIVATION OF HEAT DETECTOR. O SMOKE DETECTOR LOCATED IN ELEVATOR LOBBY. 3p FLASHING WARNING LIGHTS LOCATED ADJACENT TO ELEVATOR CALL BUTTON AT PRIMARY & ALTERNATE ACCESS LEVELS EO SMOKE DETECTOR(S) AND 135 DEGREE F FIXED TEMPERATURE HEAT DETECTOR(S) LOCATED AT TOP OF SHAFT. SMOKE DETECTOR SHALL NOT BE INSTALLED IN AN UNSPRINKLERED HOISTWAY UNLESS IT IS FOR ACTIVATION OF HOISTWAY SMOKE RELIEF EQUIPMENT. FIRE LITE MS5 BUILDING TYPE 3 � i I- I BUILDING TYPE 2 FIRELITE MMF-300 ADDRESSABLE MONITOR MODULES TO MONITOR ALARM, TROUBLE AND SUPERVISORY CONTACTS ON PANEL. (TYPICAL) FIRELITE 1300 ISOLATOR MODULE. (TYPICAL) FIRE LITE MS5 FIRE ALARM SYSTEM COMMUNICATIONS DIAGRAM NO SCALE FIRE ALARM CONTROL PANEL - COMMUNITY BUILDING/BLDG TYPE DEVICE QTY STAND-BY CURRENT AMPS TOTAL STAND-BY CURRENT AMPS ALARM CURRENT AMPS TOTAL ALARM CURRENT AMPS FACP 1 0.1000000 0.10000 0.460000C 0.460000 REMOTE ANNUNCIATOR 1 0.2700000 0.27000 0.270000C 0.270000 MINI SOUNDER MINI SOUNDER W STROBE 84 0.0000000 0.00000 0.018000C 1.512000 19 0.000000C 0.0000C 0.177000C 3.363000 SMOKE DETECTOR AND BASE 5 0.010000C 0.000600C 0.000000 0.0500C 0.055000C 0.008000C 0. 11 0000 0.275000 0.096000 2.640000 PULL STATION 12 0.0072C O.0000C HORN STROBE 24 MONITOR MODULE 2 0.006000 0.0120(.0.060000C 0.120000 HEAT DETECTOR AND BASE 2 0.002000q 0.0040q 0.0080000 0.016000 STROBE 15cd 2 0.000000 0.0000 0.0550000 0.110000 TOTAL 0.44320 TOTAL 8.86200 BATTERY CALCULATIONS Required Standby Time Non -Alarm Load Am s 0.44 A x 24 Hours = I 10.64 AH Required Alarm Time 5 Minutes Alarm Load (Amps) 8.86 A x 0.084 = 0.74 AH Standby and Alarm Load Subtota 11.38 AH Derating Factor x 1.2 Total Ampere Hours Requirec 13.66 AH FIRE ALARM CONTROL PANEL - BLDG TYPE 2 DEVICE QTY STAND-BY CURRENT AMPS TOTAL STAND-BY CURRENT AMPS ALARM CURRENT AMPS TOTAL ALARM CURRENT AMPS FACP MINI SOUNDER 1 0.100000C 0.000000C 0.10000 0.00000 0.460000C 0.460000 _ 2.052000 114 0.018000C MINI SOUNDER W STROBE 5 O.000000C 0.00000 0.177000C 0.885000 SMOKE DETECTOR AND BASE 5 0.010000C 0.0500C 0.055000C 0.275000 PULL STATION 10 0.000600C 0.0060C 0.008000C 0.080000 HORN STROBE MONITOR MODULE HEAT DETECTOR AND BASE 12 0.000000C 0.0000C 0.110000C 1.320000 2 0.006000C 0.01 20C 0.060000C 0.120000 2 0.002000q 000400 0.00800oq 0.016000 TOTAL 0.17200 TOTAL 5.20800 BATTERY CALCULATIONS Non -Alarm Load (Amps) r 0.17 A x Alarm Load (Amps) I 5.21 A x Required Standby Time 24 Hours_ _ Required Alarm Time 5 Minutes - 0.084 = Standby and Alarm Load Subti Derating Fa( Total Ampere Hours Requ 4.13 AH 0.44 AH 4.57 AH x 1.2 5.48 AH FIRE ALARM CONTROL PANEL - BLDG TYPE 3 DEVICE QTY STAND-BY CURRENT TOTAL STAND-BY ALARM CURRENT TOTAL ALARM AMPS CURRENT AMPS AMPS CURRENT AMPS FACP 1 0.1000000 0.10000 0.4600000 0.460000 MINI SOUNDER 88 0.0000000 0.0000 0.0180000 1.584000 MINI SOUNDER W STROBE 8 0.0000000 0.0000 - 0.1770000 1.416000 SMOKE DETECTOR AND BASE 5 0.010000 0.0500 0.055000C 0.275000 PULL STATION 10 0.000600 0.0060 0.008000C 0.080000 HORN STROBE 12 0.000000 _ 0.0000 0. 11 0000 1.320000 MONITOR MODULE 2 0.006000 0.0120C.0.060000 0.120000 HEAL DETECTOR AND BASE 2 0.002000 0.0040 0.008000 0.016000 IOIAL 0.1/200 IOIAL 5.2/100 BATTERY CALCULATIONS Required Standby Time T 4.13 AH Non -Alarm Load (Amps) 0.17 A x 24 Hours Required Alarm Time 5 Minutes Alarm Load (Amps) 5.27 A x 0.084 = 0.44 AH Standby and Alarm Load Subtota 4.57 AH Derating Factor x 1.2 Total Ampere Hours Requirec 5.48 AH BUILDING TYPE 3 I FIRE LITE MS5 4,('Vrn (Veir� r4-f1 M',W fi��2�Le S✓ LZ Ud i/� "Oa �bU Ua[ 4- 3�� �� valbe Oak 38S ] b �&"f-y "I'_' � fM43 � ll1772 1// '40 �"' cb;' i�o 0 Mrot.0 fZ�12 David Hunter &Associates, Inc. 12291 Sumter Square Drive West Jacksonville, Florida 32218 Tel: 904.662.2445 Fax: 904.751.1205 EB #00009882 DHA Number: D010021 0 O LL_ J W z LU N ILL 0 c 0 .y G� m Cn rn a� a 0 0 .y CD Cr. h Cn Li Drawn By D. H. Checked By E. Y. Job Number D010021 FIRE ALARM LEGEND RISER AND CALCULATIONS FA-1 C,D 0— M3-03 M3-02 M3-01 THIRD FLOOR B,D F M2-03 M2-02 M2-01 SECOND FLOOR A,D - F F H H Mt-11 M1-10 M1-09 M1-08 M1-07 M1-06 Mt-05 M1-04 M1-03 Mi-02 Ig[Q ♦ M1-01 FIRST FLOOR C,D M3-03 M3-02 143-01 THIRD FLOOR B,D r r M2-03 M2-02 M2-01 SECOND FLOOR A,D - H H F M1-11 M1-10 M1-09 M1-08 M1-07 M1-06 M1-05 MI-04 M1-03 M1-02 Q ♦ M1-01 FIRST FLOOR THIRD FLOOR SECOND FLOOR FIRST FLOOR S3 S3-01 S3-02 S3-03 S3-04 S3-05 S3-06 S3-07 S3-08 S3-09 S3-10 S3-11 S3-12 S3-13 S3-14 S3-15 S3-16 S3-17 S3-18 S3-19 Sy 7-- C,D,S3 S2 S2-01 S2-02 S2-03 S2-04 S2-05 S2-06 S2-07 S2-08 S2-09 S2-10 S2-11 S2-12 S2-13 S2-14 S2-15 S2-16 S2-17 S2-18 S2-19 Si B,C,D,S2,S3 S1 5 S S S1-01 S1-02 S1-03 S1-04 S1-05 S1-06 S1-07 S1-08 S1-09 S1-10 S1-11 S1-12 S1-13 S1-14 S1-15 S1-16 S1-17 S1-18 S1-19 S1 FACP DEDICATED TELEPHONE CONNECTION FOR THIRD PARTY NOTIFICATION DIALER 0 S3 S S3-01 S3-02 S3-03 C,D,S3 S2 S3-22 S3-23 S3-24 S3-25 S3-26 S3-27 S3-28 S3-29 S3-30 S3-31 S3-32 S3-33 S3-34 -25 S1-26 St-27 S1-28 S1-29 S1-30 S1-31 S1 FIRE ALARM RISER DIAGRAM - BUILDING 3 NO SCALE S3-08 S3-09 S3-10 S3-11 S3-12 S3-13 S3-14 S3-15 S3-16 S3-17 S3-18 S3-19 S3-20 S3-21 S3-22 S3-23 S3-24 S3-25 S3-26 S3-27 S3-30 S3-31 S3-32 S3-33 S3-34 S3-35 S3-36 WIRE TABLE A - 16/2 TWISTED PAIR, NON -SHIELDED, ADDRESSABLE LOOP 'A' B - 16/2 TWISTED PAIR, NON -SHIELDED, ADDRESSABLE LOOP 'B' S1 - 14/2 JACKETED INDICATING CIRCUIT 'S1', POWER LIMITED S2 - 14/2 JACKETED INDICATING CIRCUIT 'S2', POWER LIMITED S3 - 14/2 JACKETED INDICATING CIRCUIT 'SS, POWER LIMITED S4 - 14/2 JACKETED INDICATING CIRCUIT 'S4', POWER LIMITED D - 14/2 TWISTED PAIR, NON -SHIELDED, 24 VOLT DC POWER FIRE ALARM RISER DIAGRAM NOTES 1. ALL CONDUIT TO BE 3/4" MIN. U.N.O. 2. SEE FLOOR PLANS FOR LOCATION AND QUANTITY OF DEVICES SHOWN ON F.A. RISER. 3. WIRE FIRE ALARM SYSTEM PER MANUFACTURERS RECOMMENDATIONS. 4. ALL FIRE ALARM DEVICES SHALL MEET ADA CODES. 5. ARE ALARM SYSTEM SHALL BE INSTALLED PER NFPA AND ALL LOCAL CODES. 6. PROVIDE 3 CONTROL RELAYS FOR ELEVATOR CONTROLLER. COORDINATE WITH ELEVATOR CONTRACTOR. 0 S2-01 S2-02 S2-03 S2-04 S2-05 S2-06 S2-07 S2-08 S2-09 S2-10 S2-11 S2-12 S2-13 S2-14 S2-15 S2-16 S2-17 S2-18 S2-19 S2-20 S2-21 S2-22 S2-23 S2-24 S2-25 S2-26 S2-27 S2-28 S2-29 S2-30 S2-31 S2-32 S2-33 S2-34 S2-35 S2-36 S2-37 S2-38 S2-39 S2-40 S2-41 S2-42 B,C,D,S2,S3 S1 S1-01 S1-02 S1-03 S1-04 S1-05 S1-06 S1-07 S1-08 S1-09 S1-10 S1-11 S1-12 S1-13 S1-14 S1-15 S1-16 S1-17 S1-18 S1-19 S1-20 S1-21 S1-22 S1-23 S1-24 S1-25 S1-26 S1-27 S1-20 S1-29 S1-30 S1-31 S1-32 S1-33 S1-34 S1-35 S1-36 S1-37 S1-38 S1-39 S1-40 S1-41 S1-42 FACP 0 0 C,D S3 FJ 143-03 M3-02 M3-01 S C,D,S3 DEDICATED TELEPHONE CONNECTION FOR THIRD PARTY NOTIFICATION DIALER FIRE ALARM RISER DIAGRAM - BUILDING 2 NO SCALE 1 S3-12 S3-13 S3-14 S3-15 S3-16 S3-17 S3-18 S3-19 S3-20 S3-21 S3-22 S3-23 S3-24 S3-25 S3-26 S3-27 S3-28 S3-29 S3-30 S3-31 S3-32 S3-33 S3-34 S3-35 S3-36 S3-37 B,D S2 F FJ F s s s s s s s s s s s s s 102-03 M2-02 M2-01 S2-01 S2-02 S2-03 S2-04 S2-05 S2-06 S2-07 S2-08 S2-09 S2-10 S2-11 S2-12 S2-13 S2-14 S2-15 S2-16 S2-17 S2-18 S2-19 B,C,D,S2,S3 A,D S1 H H F F S S S S S F S S S F F F M1-13 M1-12 M1-11 M1-10 M1-09 M1-08 M1-07 M1-06 M1-05 M1-04 M1-03 M1-02 Q ♦ M1-01 S1-01 S1-02 S1-03 S1-04 S1-05 S1-06 S1-07 S1-08 S1-09 S1-10 S1-11 S1-12 S1-13 S1-14 S1-15 S1-16 S1-17 S1-18 S1-19 S1-20 S1-21 S1- FACP DEDICATED TELEPHONE CONNECTION FOR THIRD PARTY NOTIFICATION DIALER FIRE ALARM RISER DIAGRAM - BUILDING i NO SCALE S2-35 S2-36 S2-37 S2-38 S2-39 S1-38 S1-39 S1-40 St-41 S1-42 S1-43 S1-44 S1-45 S1-46 David Hunter & Associates, Inc. 12291 Sumter Square Drive West Jacksonville, Florida 32218 ..#.r•" Tel: 904.662.2445 Fax: 904.751.1205 EB #00009882 DHA Number: D010021 WC/) 0 O O�z LL 1n [---I O r� 2 a N w O Drown By D.H. Checked By E. Y. Job Number D010021 FIRE ALARM SYSTEM RISER DIAGRAMS LFA=2 4 52-21 MO D® 52-22 S S2 -20 '%0 M2-03 —A l Ar y I z r--Tti D® S2-24 52-28 DQ 52-31 DL-] S2-29 52-30 [�}4 - 121111 �� 52-36� __..._ f -... S2-25 � P i._. r- ri � � PEI - ii J S2-2s© s2-27 L.J _ I r s _ 11112-02 • _ x \ .m. Fill _4 52-1 S2-011 1 S2-38 S2-377 i� YI' 00 1Y V V'I F� l ©Id \ � , , ,-�- i u - --. s2 03 ;I DE] S2-181 �= 52-17 -- S2 15 , 10 52-09 1 �W-04 '- - s2-19 [4 D® S2-,s lh U- S2- � 52-08 CIL- I T -4 LL — (y -- _ L — 2 2ND FLOOR - BUILDING 1 - FIRE ALARM FA-3j SCALE: 3/32" = 1'-0" ulfl �r�. _.. .j r�t�w _ '�-�?wl��s•�oww�e'., 4 r _ - I =�..-_. _ _ ❑ <s..o'�li L 51-21 04 24 I S1-28 Lj4 D(:] S1-31 --� ! � �- 4 _ �---.._.u�.,.., i� S1-29 i---_- _ 51-30 �}4 jj n.I S1 2fi S 2 Yip / u..�,�T � Y � Y [� � Y � I Y r I � �, n ri ���u,r.ull��'�� F •�'` � ��,... .,i � 1 a I�fi fi� -o :; � n � ,� it '`'-�(' _ 71p, o 0 _�� - ,�-- I 11 J YL-�1_ 0�5 �t _J - 7 LL 1 g- I o r> �^ IILI���IJII J yMI-05 t. 01-06 H �51-34 51-32 l ..-T S1 33 I INSTALL IN ELEVATOR PIT UNri61 II � Y Mi-07 `"- L - M1-08 lrl== I` E n� rr°I`f M1-04 51-20 Sl- r, si-01F - - --- �- _ .. _ - _ IT hL - ol Fri 13 ni- -5-t" h. • I�-. , •' _- _ -"'-- —'�1 dJ ��'. - - _ --_ i_ i`T '--11 L. YC /!k77I i1G J Ir _n p! ---- ILL . r I IL UNrr Sl 1 .- ---,1 Do r� 51-12 �51-11 ��� � .� I p M1-03 51-15 MO Y 51-133 DM S1-08 � 51-07 MO Sl-188 m416 D® S1-14 _ al:.. -, S1-09 Ell D® S1-06 Sl- r 77 o f-: ❑ o = S1-05 51-04 DIIIEN Ina -03 1ST FLOOR - BUILDING 1 - FIRE ALARM SCALE: 3/32" = 1'-0" W x Q II — cc z �M1-o2 - --� 51-02 2 M z Ito NOTES 1. DESIGNATED AS A UFAS UNIT 2. DESIGNATED AS A VISUAL/NEARING IMPAIRED UNIT. David Hunter &Associates, Inc. 12291 Sumter Square Drive West -�+� Jacksonville, Florida 32218 Tel: 904.662.2445 Fax: 904.751.1205 EB #00009882 DHA Number. D010021 0 ►-� o w LL- wNw LU N LL o U Drawn By _ D. H. Checked By E. Y. Job Number� D070021 1ST &2ND FLOOR BUILDING TYPE 1 FIRE ALARM FA-3 17' 1�;4- �- 53-21 MI � D® 53-24 D© S3-22 S3-23 (1114 53-20 a M3-04 53-19©043-18 53-1DEJ S3-16 I ---A. L - S3-25 Dal S3- 6©104 J � a .�L.L DIM 53-155 D® 53-31 53-30 CA 53-12 � ., :. ; •I � n`r � ��--ice_ . -,� CAI � F y 53-14 S3-13 r IN 1 1 1Nrf DO S3-10 I I« a S3-09 E)-j S3-11 04 + D© S3-08 r5�j F, _ II --T INSTAII AT 10P Of'SHM I �53-34 S3-� 53-38 53-32 53-33 S3-37 I Y\1 H M3-03 F UNIT Ei'2 r 53-39 M3-02 % E S3-35011111 S3-07 S3-06 D11:51 -05 3RD FLOOR - BUILDING 1 - FIRE ALARM SCALE: 3/32" = 1'-0" M3-01 e 53-02�W CC�.1 L �53-04 J pIrm I NOTES 1. DESIGNATED AS A UFAS UNIT 2. DESIGNATED AS A VISUAL/HEARING IMPAIRED UNIT. David Hunter & Associates, Inc. 12291 Sumter Square Drive West Jacksonville, Florida 32218 Tel: 904.662.2445 Fax: 904.751.1205 N M rv�w.NNo� Xuj'-o 3z�� zo�rn n u U Q W V1 con 0 O �w ILL J J �--� r O ram-, w N ILL O U 0 cc a� G� G c 0 y .g cc 0� N N Co R C Drawn By D.//. _ Checked By E. Y. Job Number D070027 3RD FLOOR BUILDING TYPE 1 FIRE ALARM FA-4 52-42_ DaIM4 S2-41 S2-401._._-___ o El �-- uNrrN 1 1r. S2-02 S2-03 S2-Old D0[�]O M 51-02 S2-390 DMID4 52-38 52-37 11W y q_winr".:uui" uu muu�.uwu L p S2- Dm[]4 -35 j r---- Y2- _____ a0 — ,_ r UNIT81. P-3- 1, 52-066 52-07 w �— 52-08 2 -09 DM DGIEW 52-05 S1-47_ T,`�-ip3[�l Sl- 46�S1-a5 '11�pM1-11 M0 51-04 51-03 51-05 11'ZM1-01 13 -02 pm St-06 St- � IN111DO 51-43 S1-42 51-10 8 St-08 51-09 O Si-07�[0O Ell MS2-10 52-33 [$]O D® 52-32 S2-, DM 52-12 52-11 ©O M2-02 ZE D® 52-30 52-31 Ml 52-15 S2-16 52-14M DMMQ 2ND FLOOR — BUILDING 2 — FIRE ALARM SCALE: 3/32" = V-0" �[�]O -39 ry Q 51-41 51-40 q � iJIVfI°k.: = t_ --c�.� , 51-11 St-12 Domq 11114 St-38 MO D® S1-37 M1-09 MM1-08 H INSTALL IN ELEVATOR PIT H M1-07 M1-06 I yE q 8I iN �... � ., � ... �52-27 S2-26� 52-29 S2-28 ` 52-25 52-24 _.I.w �-1 I�d 52-23 M2-03 — iL JE an, �: � t S2-1i S2-18 S2-20 52-21 DOIEN S2-19 DM� -22 ...__. _ �- I I S1- Doa -35 �(N M4 -32 S1-31M DMI1114 St-34 S1-33 51-30 51-29 4 51-28 S1-1fi M1-05 8 1 m 51-15 51-14 E)4 'MM1-03 51-17 S1-19 51-20 51-21 51-22 S1-1B© DMEN tame EN -23 1ST FLOOR -BUILDING 2 -FIRE ALARM SCALE: 3/32" = V-0" M1-04 34 51-24 S1-25 51-26 DMEN 04 -27 NOTES 1. DESIGNATED AS A UFAS UNIT 2. DESIGNATED AS A VISUAL/HEARING IMPAIRED UNIT. David Hunter &Associates, Inc. 12291 Sumter Square Drive West LJacksonville, Florida 32218 Tel: 904.662.2445 stt Fax: 904.751.1205 EB #00009882 DHA Number: D010021 WC/� ►--� Z o O w EL J a N IL h�'Ti�i N w 0 m >r aU CA Ch as c�C C C C G7 CD H CID M O By FD,a,wn . f 1. ke�d/By . / . Job Number D010021 1ST & 2ND FLOOR BUILDING TYPE 2 FIRE ALARM FA-5 S3- D �� 53-39 �� WI� 34 rts_t— S3-41 53-40 53-38 53-37 53-36 S3-35 IV III a 1i AL-, - � .,I 6-4L- , g I �� I L n lll, ::_. I, -- Ty;. LINO 4 I IL+ 10 l I L�J S3-33 []4 D© 53-32 M3-02 ZE D® 53-30 S3-31 ©4 INSTALL AT TOP OF SHAFT H M -03 L-pp I- _.; - �r S3-29© 53-28 ,! / 04 -27 S3-23 iq M3-04 IL�TD l - ��-� } S3-15 S3-16 53-1753-18 14 [$] � _1 53-19 3RD FLOOR - BUILDING 2 - FIRE ALARM SCALE: 3/32" = 1'-0" 53-26 I D®P41 53-25 S3-24 L_ 53-20 S3-21 S��o 67,110 NOTES 1. DESIGNATED AS A UFAS UNIT 2. DESIGNATED AS A VISUAL/HEARING IMPAIRED UNIT. David Hunter & Associates, Inc. 12291 Sumter Square Drive West Jacksonville, Florida 32218 Tel: 904.662.2445 Fax: 904.751.1205 EB #00009882 DHA Number: D010021 Q N M �nwtq z C7rir.o z v v zoZZ vU o W O � w 0 LL J_ [-� O Wz uj N W o r U Drawn By Checked By E. Y. Job Number D010021 3RD FLOOR BUILDING TYPE 2 FIRE ALARM FA-6 D® 52-30 52-23 ON S2-34 52-31 M4 -27 52-26 DIM52-22 DM DMMQ 1 �� 52-332 � -32 52-29 52-28 S2-25 S2-24 52-21��52-20 M4 52-01 A M2-01 52-02 [01 D® S2-03 52-04DMM52-05 EN S2-O6 52-09 a S2-08 S2-07 MO M2-02 ZE S2-11 52-10 m4 52-18 M2-03 DM S2-13 D® 52-15 DM 52-17 52-12 04 S2-14 M4 S2-16 ©4 2ND FLOOR - BUILDING 3 - FIRE ALARM SCALE: 3/32" = 1'-0" M1-10 .:. •., Mi-09 - �1-08 51-29 � 51-27�Q4 - Sl-3D[�[�jS1-33 51 S151-36 -31 ,1 -26 51-23 S1-39®1114 51-35�©$-34 51-30 I �_ L .., .I _ " i , S1--25�� -24 � J INSTALL IN� LLLVATOR II YNrI �4t - I� ` r PIT H Il� H M1-07 S1-32 M1-06 S1-28 i` E M1-11 ssssss������'''"' S1-01 a nzM1-01 11 51-22 S1-08 51-05 S1-06 401111 51-02 [ ' 11114 M-02 �� I51-07 �S1 09 DM51-14 pL] 51-16 p® 51-18 p[ S1-21 DUIS1-03 51-04 M1- 4 S1-13 MQ 51-15 � S1-17 ©O M1-0� S1-20 @4 51-11 Si-19 1ST FLOOR -BUILDING 3 -FIRE ALARM SCALE: 3/32" = 1'-0" M1-05 10 /9/0//0 e6�� NOTES 1. DESIGNATED AS A UFAS UNIT 2. DESIGNATED AS A VISUAL/HEARING IMPAIRED UNIT. C<�David Hunter & Associates, Inc. ' 12291 Sumter Square Drive West - 07 Jacksonville, Florida 32218 Tel: 904.662.2445 Fax: 904.751.1205 EB #00009882 DHA Number:D010021 W� 0 f� 0 a 1� W z WNw LU N LL 0 U Drawn By D.H. Checked By E. Y. Jab Number D010021 1ST & 2ND FLOOR BUILDING TYPE 3 FIRE ALARM LFA=7 S3-34— —�DM 53-30 S3-311 53-33�3 -32 J IN 53-29®3 -28 M INSTALL AT TOP OF SHAFT H M3-03 M3-02 ZE 53-266 Dal DM 53-253 -24 53-23 [O D{l S3-22 �� 04 -19 53-21 53-20 S3-18 S3-01 53-09 I 8 _ _.�—� M3-04 M. 5V' i —, .._� 53-04 S3-05 �� 06 53-02 [$]Q D[�J 53-08 p[5] 53-11 DM 53-13 -15 17 DO 53-03 S3-07 00 S3-10 � 53-12 MO 53-144 Q 53-16© SO4 3RD FLOOR - BUILDING 3 - FIRE ALARM SCALE: 3/32" = V-0" l �ryr� NOTES 1. DESIGNATED AS A UFAS UNIT 2. DESIGNATED AS A VISUAL/HEARING IMPAIRED UNIT. 0David Hunter &Associates, Inc. 12291 Sumter Square Drive West Jacksonville, Florida 32218 Tel: 904.662.2445 Fax: 904.751.1205 FB #00009882 DHA Number: D010021 W� 0 O w ILL. J WNw Uj N ° U Drawn �� D. H. Checked By E. Y. Job Number� D010021 3RD FLOOR BUILDING TYPE 3 FIRE ALARM FA-8 c O .N W W W N O c 0 y .j C7 N N 0O G Z Z J H H Q Q 0 M1-10 Sl —39 a -05I D❑F IND F M1-11 )6 S1-36 S1-37 F M1-09 51-40 S1-38 S1-41� F V Q S1-42 S1-35 a 4 S1-43 S1-49 F M1-12 ❑F S1-45 S1-44 M1-02 El S1-48 51-47 S1-46 � F a LFJ M1-13 F W W Z Z J J H H QQ 1 FLOOR PLAN - COMMUNITY CENTER - FIRE ALARM FA-9 SCALE: 1 /8" = V-0" NOTES 1. DESIGNATED AS A UFAS UNIT 2. DESIGNATED AS A VISUAL/HEARING IMPAIRED UNIT. David Hunter &Associates, Inc. Ito 12291 Sumter Square Drive West --..7 Jacksonville, Florida 32218 Tel: 904.662.2445 Fax: 904.751.1205 EB #00009882 DHA Number: D010021 0 � DC O O�w I J ti J WZ a Uj LL U c a .y a� ac m N m 0 0 .y as Cn a� c Drawn By D. H. Checked By E. Y. Job Number D010021 COMMUNITY CENTER BUILDING TYPE 1 FIRE ALARM