Loading...
HomeMy WebLinkAbout38439, 38659 Valley Oaks Lp (SW & NW)ARCHITECTURAL SHEETS Q m U Cn Q O LO u7 O O O O N M C O N 19 O d 3 -v 0 M O `b, Meetinghouse at Zephyrhills Senior Apartments Trash Compactor Enclosure Zephyrhills, FL mFORUME v r Q L 0, ARCHITECTURE & INTERIOR DESIGN, INC. .N PLANNING I ARCHITECTURE I INTERIOR DESIGN m 0 6 745 orienta avenue, suite 1121 altamonte springs, fl 32701 c phone: 407.830.1400 fax: 407.830.4143 AA0002731 www.forumarchitecture.com Meetinghouse at Zephyrhills Senior Apartments City of Zephyrhills, FL v �e m� Uj d SE DISTRIBUTIONS: EDITED BY: U i PROJECT NO. 09-2587 z 0 co W Trash Compactor o p Enclosure Title Sheet, LU z Drawing Index & LU Issue History U w U Al 9,30 0 LL CONCRETE MASONRY UNITS FOUNDATION GENERAL CODES 01 ALL CONCRETE MASONRY UNITS SHALL BE HOLLOW LOAD BEARING UNITS CONFORMING TO ASTM C90, GRADE N, TYPE I, WITH MINIMUM COMPRESSIVE STRENGTH OF UNITS =1,900 PSI ON NET AREA, WITH ASSUMED DESIGN COMPRESSIVE STRENGTH, F'M =1,500 PSI. UNITS MAY BE FABRICATED EITHER WITH NORMAL WEIGHT AGGREGATE (C33) OR WITH LIGHTWEIGHT AGGREGATE (C331). 02 ALL UNITS SHALL BE PLACED IN RUNNING BOND. 03 MORTAR SHALL BE TYPE M OR S. MIX 1 PART PORTLAND CEMENT,1/4 TO 1/2 PART HYDRATED LIME AND 2-1/4 TO 3 PARTS SAND, MIXED ON SITE. 04 STORE ALL UNITS OFF GROUND TO PREVENT CONTAMINATION. COVER MATERIALS TO PROTECT FROM THE ELEMENTS. 05 NO AIR -ENTRAINING ADMIXTURES OR ANTIFREEZE COMPOUNDS, SUCH AS CALCIUM CHLORIDE SHALL BE ADDED TO MORTAR. 06 ALL WALLS OR PILASTERS SUPPORTING STEEL AT BEARING PLATES SHALL BE GROUTED SOLID FOR FOUR COURSES IN DEPTH FOR A WIDTH OF 32". 07 DO NOT BACKFILL AGAINST FOUNDATION WALLS UNTIL MORTAR HAS ATTAINED MAXIMUM STRENGTH. WHERE BACKFILL IS PLACED AGAINST FOUNDATION WALLS BEFORE FLOOR CONSTRUCTION IS IN PLACE, PROVIDE TEMPORARY BRACING. 08 THE FIRST BLOCK COURSE ON FOOTING SHALL BE FILLED SOLID WITH CONCRETE, UNLESS NOTED OTHERWISE IN DRAWINGS. 09 VERTICAL CONTROL JOINTS SHALL BE PLACED SUCH THAT THE RATIO OF JOINT SPACING (L) DIVIDED BY WALL HEIGHT (H) DOES NOT EXCEED 3.0. IN NO CASE SHALL SPACING EXCEED 50 FEET. CONTROL JOINTS SHALL BE CONSTRUCTED USING SASH BLOCKS AND DUR-O-WALL PREFORMED REGULAR RAPID CONTROL JOINT (OR EQUAL OF EXTRUDED RUBBER). WALL REINFORCING SHALL BE DISCONTINUOUS AT JOINTS. VERTICAL JOINTS SHALL BE LOCATED AS FOLLOWS: A CHANGES IN WALL HEIGHT. B AT CONSTRUCTION JOINTS IN FOUNDATION, IN ROOF AND IN FLOORS. C AT CHASES AND RECESSES FOR PIPING, COLUMNS, FIXTURES, ETC. D AT ABUTMENT OF WALL AND COLUMNS. E AT RETURN ANGLES IN'L','T' AND'U' SHAPED STRUCTURES. F AT ONE OR BOTH SIDES OF WALL OPENING. 10 CMU WALLS SHALL BE REINFORCED WITH TRUSS TYPE REINFORCING OF 9 GAGE ASTM A82 WIRE, GALVANIZED AT 16" ON CENTER (VERTICALLY), AND AT THE FIRST AND SECOND BED JOINTS ABOVE AND BELOW WALL OPENINGS. 11 ALL MASONRY WALLS SHALL BE ADEQUATELY BRACED DURING CONSTRUCTION TO RESIST WIND LOADS OF 25 PSF. NOTE THAT FLOOR AND ROOF DIAPHRAGMS WILL PROVIDE ULTIMATE STABILITY FOR WALLS. UNTIL THESE ARE IN PLACE, MASONRY WALLS SHALL NOT BE BUILT HIGHER THAN 10 TIMES THEIR THICKNESS WITHOUT BRACING. a) 0 U) a M 0 cc o) CD 0 O N ti a 0 CD 0 d rn 3 M CD ti 00 U a� E g 0 U 7 0 n. co N a Q 01 FOUNDATIONS HAVE BEEN DESIGNED TO AN ALLOWABLE SOIL BEARING PRESSURE OF 2,000 PSF. SHOULD CONDITIONS VARY FROM THE ASSUMED, THE ARCHITECT SHALL BE NOTIFIED BEFORE CONTINUATION OF WORK. 02 ALL FOOTINGS SHALL BE PLACED DIRECTLY ON VIRGIN SOIL, OR CERTIFIED COMPACTED FILL. 03 CONCRETE FOR FOUNDATIONS: A 28 DAY COMPRESSIVE STRENGTH FOR CONCRETE SHALL BE AS FOLLOWS: FOOTINGS 3000 PSI SLAB ON GRADE 3000 PSI WALLS 3500 PSI B MAXIMUM CONCRETE SLUMP SHALL BE 4". C SLAB ON GRADE SHALL BE 5" THICK WITH WWF 6 x 6 -W1.4 x W1.4. SLAB SHALL BE FINISHED IN ACCORDANCE WITH ACI STANDARD 302 FOR CLASS 2 FLOORS. IN LIEU OF WWF, SLAB ON GRADE MAY CONSIST OF FIBER REINFORCED CONCRETE ACI 544.2R-89. D ALL CONCRETE SHALL BE MIXED, TRANSPORTED AND PLACED IN ACCORDANCE WITH ACI STANDARDS 318, 304 AND 301. E ALL REINFORCING BARS SHALL BE OF BILLET STEEL CONFORMING TO ASTM A615, GRADE 60. F ALL WELDED WIRE MESH SHALL CONFORM TO ASTM A185. G ALL VERTICAL SURFACES OF CONCRETE SHALL BE FORMED FOR WALLS AND FOOTINGS. H REINFORCING STEEL SHALL BE PLACED TO PROVIDE THE FOLLOWING MINIMUM CONCRETE COVER: SLAB ON GRADE 1-1/2" WALLS 2" FOOTINGS 3" I GRADE BEAMS SHALL BE FORMED ON SIDES. 04 ALL FILL SHALL BE PLACED IN 8 INCH LOOSE LIFTS (MAXIMUM) COMPACTED WITH VIBRATORY ROLLERS. FILL MATERIAL SHALL BE TESTED BY MODIFIED PROCTOR DENSITY METHOD (ASTM D1557) AND MUST QUALIFY AS SELECT, WITH LESS THAN 10% PASSING THROUGH THE NO.200 SIEVE. SOIL SHALL BE PLACED WITH MOISTURE CONTENT AND ENERGY TO PROVIDE 98% OF MAXIMUM DRY DENSITY BELOW SLABS ON GRADE, AND SOIL SHALL BE COMPACTED TO 98% 12" AND 24" BELOW STRIP FOOTINGS AND COLUMN FOOTINGS, RESPECTIVELY. IN PLACE DENSITY TESTS SHALL BE TAKEN FOR EACH 2,000 S.F. IN EACH LIFT. FOR ACCEPTANCE OF SOIL, AVERAGE OF DENSITY TESTS MUST EXCEED THE SPECIFIED COMPACTION. NO TESTS SHALL BE PERMITTED TO FALL BELOW 90% COMPACTION. 05 ALL EXTERIOR FOOTINGS SHALL BE PLACED A MINIMUM OF 2'-0" BELOW FINAL GRADE WHEN BEARING ON SOIL, UNLESS NOTED OTHERWISE ON THE FOUNDATION DRAWINGS. 06 WHERE NECESSARY, FOOTING STEPS SHALL BE CONSTRUCTED AT MAXIMUM SLOPE OF 1 VERTICAL TO 2 HORIZONTAL. 07 WHERE ROCK OUTCROPPINGS ARE ENCOUNTERED IN A BUILDING FOUNDATION BEARING ON SOIL, SUCH OUTCROPPING OR INTERFERENCE SHALL BE REMOVED TO A DEPTH 12 INCHES BELOW BOTTOM OF FOOTING AND REPLACED WITH CLEAN GRANULAR MATERIAL CONTAINING LESS THAN 5% SILT, COMPACTED TO 95% DENSITY PER MODIFIED PROCTOR METHOD. MAINTAIN A MINIMUM COVER OF 1'-6" TO BOTTOM OF CONCRETE. 08 WHERE SOLID UNFRACTURED ROCK IS ENCOUNTERED FOR A WALL LENGTH OF AT LEAST 25 FEET, WALLS MAY BE POURED WITHOUT FOOTINGS BY TRENCHING 6 INCHES INTO THE ROCK AND PINNING THE WALL TO ROCK WITH #6 x T-0" LONG DOWELS AT 2'-8" ON CENTER, GROUTED INTO ROCK, EXTENDING 1'-6" INTO ROCK. NO FROST PROVISIONS ARE REQUIRED FOR THIS DETAIL. PROVIDE CONTROL JOINT IN WALL AT ANY TRANSITION BETWEEN ROCK BEARING AND SOIL BEARING CONDITIONS. 09 EXCAVATIONS SHALL BE DEWATERED TO A DEPTH OF AT LEAST 2 TO 3 FEET BELOW THE BOTTOM OF THE EXCAVATIONS TO ALLOW INSTALLATION OF FOOTINGS IN DRY ATMOSPHERE. 10 DIFFERENTIAL BACKFILL AGAINST FOUNDATION WALLS SHALL NOT EXCEED FOUR FEET UNTIL TOP BRACING OR FRAMEWORK HAS BEEN IN PLACE FOR A MINIMUM OF THREE DAYS. CANTILEVERED RETAINING WALLS MAY BE BACK -FILLED WITHIN 14 DAYS OF CONCRETE PLACEMENT, BUT IN NO CASE SHALL DIFFERENTIAL OF BACKFILL, BETWEEN OPPOSITE SIDES OF THE WALL, EXCEED THE FINAL DESIGN DIFFERENTIAL. 11 ALL BOTTOM OF FOOTING ELEVATIONS ARE SUBJECT TO CHANGE UPON INSPECTION OF SOIL CONDITION. ELEVATION OF ADJACENT FOOTINGS SHALL VARY ON A SLOPE NOT STEEPER THAN ONE VERTICAL TO TWO HORIZONTAL. 12 THE CONTRACTOR SHALL NOTIFY THE ENGINEER WHERE BOTTOM OF FOOTING ELEVATION IS CHANGED AND OBTAIN REVISED DESIGN OF THE FOUNDATION AND RETAINING WALLS AS REQUIRED. 13 A MINIMUM 6-MIL POLYETHYLENE VAPOR BARRIER BETWEEN THE BOTTOM OF THE FLOOR SLAB AND THE TOP OF THE COMPACTED SUBGRADE SHALL BE INSTALLED. 01 CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLYING WITH ALL APPLICABLE CODES AND MUST NOTIFY ARCHITECT OF DISCREPANCIES INDICATED BY THESE DOCUMENTS FOUND DURING BIDDING AND PRIOR TO PROCEEDING WITH THE WORK. 02 DRAWINGS ARE DEVELOPED TO ILLUSTRATE SIZE, ASSEMBLY, RELATIONSHIP, QUANTITY, AND IDENTIFICATION OF BUILDING COMPONENTS. DOCUMENTS WORK IN CONJUNCTION WITH SPECIFICATIONS REGARDING EXACT REQUIREMENTS OF PRODUCTS, INSTALLATION QUALITY, STANDARD EXECUTION OF WORK, AND CLASSIFICATIONS. 03 ALL TRADES MUST REVIEW ALL CONSTRUCTION DOCUMENTS AND ARE RESPONSIBLE FOR ALL WORK ASSOCIATED WITH THEIR TRADES IN THESE DOCUMENTS. DO NOT BASE SCOPE OF WORK ONLY ON A REVIEW OF THE SHEETS TYPICALLY ASSOCIATED WITH THE TRADE'S SCOPE OF WORK. 04 DO NOT SCALE DRAWINGS. USE ONLY WRITTEN DIMENSIONS. 05 THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS, SHALL VERIFY EXISTING TOPOGRAPHY AND GRADE ELEVATIONS, AND SHALL NOTIFY ARCHITECT OF ANY DISCREPANCIES PRIOR TO PROCEEDING WITH THE PROJECT. 06 THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR AND HAVE CONTROL OVER CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES, INCLUDING ALL SAFETY PRECAUTIONS AND PROGRAMS, AND FOR COORDINATING ALL PORTIONS OF THE WORK. 07 ADDRESSES: APPROVED NUMBERS OR ADDRESSES SHALL BE PROVIDED FOR THE BUILDINGS SO THAT THE NUMBERS OR ADDRESS IS PLAINLY VISIBLE AND LEGIBLE FROM THE STREET OR ROADWAY. THE NUMBERS SHALL CONTRAST WITH THEIR BACKGROUND. ADDRESS NUMBERS SHALL BE DETERMINED BY THE OWNER. 08 DIMENSIONS SHOWN ARE TO FACE OF CONCRETE MASONRY UNITS, FACE OF STUD, MASONRY OPENING, OR ROUGH OPENING AT STUD WALLS. 09 THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING AND SUBMITTING PRODUCT APPROVAL SHEETS AND DATA TO THE BUILDING DEPARTMENT IN THE FORM THE BUILDING DEPARTMENT REQUIRES FOR ANY PRODUCT SELECTION THAT IS CHANGED BY THE OWNER AND/OR THE CONTRACTOR FROM THE PRODUCT ORIGINALLY SPECIFIED AND SUBMITTED BY THE ARCHITECT. THE CONTRACTOR MUST FIRST SUBMIT THE NEW PRODUCT DATA TO THE ARCHITECT FOR REVIEW AND APPROVAL BEFORE SUBMITTING THE REQUIRED PRODUCT APPROVAL SHEETS AND DATA TO THE BUILDING DEPARTMENT. E SITE WORK 01 SOIL BEARING VALUES. FOUNDATION DESIGNS ARE BASED ON AN ESTIMATED SOIL BEARING VALUE OR ACTUAL VALUE AS SPECIFIED BY A GEOTECHNICAL ENGINEER AND NOTED ON THE DRAWINGS. FOUNDATIONS AND SLABS ARE DESIGNED TO UNIFORMLY BEAR ON WELL COMPACTED, WELL DRAINED NON -EXPANSIVE SOILS. A CERTIFIED SOILS ENGINEER SHALL REVIEW FOUNDATION DESIGNS, BUILDING LOADS, AND COMPARE WITH SUBSURFACE SOIL INVESTIGATION RECOMMENDATIONS. SHOULD ON -SITE OBSERVATIONS SHOW THAT FOOTINGS SHOWN HERE ARE NOT SATISFACTORY, THE ARCHITECT SHALL BE CONTACTED IMMEDIATELY FOR REVISED DESIGNS. 02 THE CONTRACTOR SHALL PROVIDE ALL OF THE FOLLOWING SITE REQUIRED ITEMS, BUT NOT LIMITED TO: SITE UTILITIES, SLEEVES, CONDUIT, PULL BOXES, STRUCTURAL BASES, FOOTINGS, ETC. DESCRIBED OR REQUIRED AS PART OF A COMPLETE SYSTEM ON CIVIL ENGINEERING, LANDSCAPE, SWIMMING POOL, ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL OR PLUMBING DRAWINGS. COORDINATE FULLY WITH ALL UTILITY COMPANIES TO DETERMINE WHAT COMPONENTS ARE PROVIDED BY THE UTILITY COMPANIES. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR ALL ITEMS NOT SUPPLIED BY THE UTILITY COMPANY. 03 REFER TO CIVIL ENGINEERS SITE PLAN AND DETAILS FOR ACTUAL BUILDING LOCATIONS, FINISHED GRADES, FLOOR ELEVATIONS, UTILITIES, DRAINAGE, ETC. 04 REFER TO LANDSCAPE ARCHITECT AND/OR POOL DESIGNER'S PLANS FOR LANDSCAPING, FENCES, POOL DESIGN, IRRIGATION, EXTERIOR FURNISHINGS, TRAFFIC CONTROL, AND OTHER DECORATIVE LIGHT FIXTURES, ETC. 05 CLEARANCE BETWEEN EXTERIOR WALL COVERINGS AND FINAL GRADE ON THE EXTERIOR OF BUILDING SHALL NOT BE LESS THAN 6 INCHES, (U.N.O.) 06 NOTICE OF TERMITE PROTECTION. A PERMANENT SIGN WHICH IDENTIFIES THE TERMITE TREATMENT PROVIDER AND NEED FOR REINSPECTION AND TREATMENT CONTRACT RENEWAL SHALL BE PROVIDED. THE SIGN SHALL BE POSTED NEAR THE WATER HEATER OR ELECTRICAL PANEL. GENERAL - STRUCTURAL 01 THESE STRUCTURAL PLANS HAVE BEEN PREPARED IN ACCORDANCE WITH THE APPLICABLE STRUCTURAL CHAPTERS OF THE 2007 FLORIDA BUILDING CODE. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THIS CODE AND ALL LOCAL REQUIREMENTS. 02 DESIGN LOADS: A SEE DESIGN CRITERIA ON STRUCTURAL DRAWING. B FLOOR LIVE LOADS HAVE BEEN REDUCED IN ACCORDANCE WITH CODE FOR GIRDERS AND COLUMNS. C WIND LOAD: SEE REQUIRED DESIGN WIND PRESSURES ON STRUCTURAL DRAWINGS. D COMPONENTS AND CLADDING: SEE REQUIRED DESIGN WIND PRESSURES ON STRUCTURAL DRAWINGS. 03 ALL WORK SHALL BE COORDINATED WITH ARCHITECTURAL, MECHANICAL, ELECTRICAL AND PLUMBING DRAWINGS. CONFLICTS IN DIMENSION AND INTERFERENCE SHALL BE DIRECTED TO THE STRUCTURAL ENGINEER PRIOR TO CONSTRUCTION OF WORK. 04 THE CONTRACTOR SHALL CHECK THE BUILDING LOCATIONS WITH REGARD TO PROPERTY LINE AND VERIFY ALL EXISTING CONDITIONS PRIOR TO EXCAVATION AND SHOP DRAWING PREPARATION. NOTIFY THE ARCHITECT 1 ENGINEER OF ANY DISCREPANCIES. 05 IN CASE OF CONTRADICTION BETWEEN THE DRAWINGS, THE SPECIFICATIONS AND THE CODES, OR IF ANY CHANGE IS REQUIRED, THE CONTRACTOR SHALL INFORM THE ENGINEER IMMEDIATELY. NO CHANGE SHALL BE MADE WITHOUT WRITTEN APPROVAL OF THE ARCHITECT I ENGINEER. FLORIDA BUILDING CODE - BUILDING 2007 W/ APPLICABLE SUPPLEMENTS FLORIDA FIRE PREVENTION CODE 2007 EDITION NATIONAL ELECTRIC CODE 2008 EDITION ACCESSIBILITY IN ADDITION TO CODES LISTED ABOVE, ACCESS TO AND THROUGH THIS AMENITY IS DESIGNED TO CONFORM TO THE FAIR HOUSING ACT OF 1988 AND AMENDMENTS AND FLORIDA ACCESSIBILITY CODE. M SUMMARY BUILDING TYPE NO. OF BLDGS. A/C AREA NON A/C AREA TOTAL AREA TRASH COMPACTOR ENCLOSURE 1 908 SF 908 SF 0 CODE COMPLIANCE OCCUPANCY TYPE U UTILITY CONSTRUCTION TYPE V-B AREA & HEIGHT LIMITATION (FBC-B TABLE 503): REQUIRED/ALLOWED PROPOSED MEAN HEIGHT 40' 9'-4" MAXIMUM NUMBER OF FLOORS 1 STORY 1 STORY MAXIMUM AREA 5,500 SF 908 SF FIRE PROTECTION (FBC-B TABLES 601 & 602): INTERIOR BEARING WALLS 0 HR 0 HR INTERIOR NON -BEARING WALLS 0 HR 0 HR COLUMNS 0 HR 0 HR BEAMS, GIRDERS & TRUSSES 0 HR 0 HR FLOOR/CEILING ASSEMBLY 0 HR 0 HR ROORCEILING ASSEMBLY 0 HR 0 HR EXTERIOR BEARING WALLS 0 HR 0 HR EXTERIOR NON -BEARING WALLS 0 HR 0 HR aFORUME 13 r 0 ARCHITECTURE & INTFRIC)R DFSIGN_ INC_ PLANNING I ARCHITECTURE I INTERIOR DESIGN m 0 0 745 orienta avenue, suite 1121 m altamonte springs, fl 32701 c phone: 407.830.1400 fax: 407.830.4143 AA0002731 www.forumarchitecture.com r Meetinghouse at Zephyrhills Senior Apartments City of Zephyrhills, FL ti 0 CL / U m� F w EDITED BY: PROJECT NO. 09-2587 A 19.31 ■ Maximum Area of Exterior Wall Openings 0 SHEET NOTES Per Table 704.8 & Section 704.8.1 FBC 2007) A REFER TO SHEET A1.03 FOR GENERAL NOTES 3 Building Side or Portion Distance To % Opening % Opening Building Type of Building Property Line Allowed Provided 1 1 Rear Elev. 19'-9" 75% 36% 4 III Right Elev. 10, 10% 6% 4 111 Rear Elev. 21' 45% 30% 3 11 Right Elev. ....................................... 10'-6" . 15% 6.5% 3 11 Rear Elev. 2V-0" 45% 34% 2 111 Right Elev. 8'-10" 21' 10% 45% 6% 2 111 Rear Elev. 28% 1 1 Right Elev. 6-10" 25% 19% -- -- -- -= -- -- '-------+----i--��---i--i�--_i-- ���--��--��--��----- - --- -- -- -- --- -- � - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1 TRASH COMPACTOR I ENCLOSURE 1 — 10'-6 118" Lin I I I 1 Q I 3 I ll NIC II 42 ON POOL PA I \� I \ I I 1 1 I I I I I 1 1 I Architectural Site Plan 4 TRELLIS � I III 39 ® °p� I VAC PACK (BY OTHERS)/ 14 I I J I C I UFAS UNITS ON 2ND/ \/ 3R S. ONLY AT THIS ION MONUMENT SIGN (BY OTHERS) WIRE ROAD I -t I 1 I I I I I I 1 1 I 1 GARAGE TRASH COMPACTOR II ENCLOSURE 1 "=50'-0" NORTH B REFER TO CIVIL PLANS FOR ALL SIDEWALK LOCATIONS, HANDICAP PARKING AND ACCESSIBILITY DETAILS, AND BUILDING LOCATIONS C COORDINATE ENTRY GATE SYSTEM LOCATIONS AND REQUIREMENTS WITH SYSTEM MANUFACTURER D CONTRACTOR TO VERIFY CONDENSER PAD LOCATIONS WITH SITE CONDITIONS E FLORIDA YARDS & NEIGHBORHOOD CERTIFICATION IS REQUIRED ON ALL LANDSCAPING. LEGEND -- BUILDING NUMBER X _ - NO. OF UNITS X X BUILDING TYPE LOCATION OF UFAS UNITS SITE PLAN HAS BEEN REVISED TO COORDINATE WITH CIVIL DRAWINGS. 9 1 FORUME L 0 C_ ARCHITECTURE & INTERIOR DESIGN, INC. _rn PLANNING I ARCHITECTURE I INTERIOR DESIGN 745 orienta avenue, suite 1121 altamonte springs, fl 32701 phone: 407.830.1400 fax: 407.830.4143 AA0002731 www.forumarchitecture.com Meetinghouse at Zephyrhills Senior Apartments City of Zephyrhills, FL V Y U � m mo CD o' MQ SETIDISTRIBUTIONS: 11/25/09 Progress Set 12/09/09 60% Progress Set 12/17/09 Bid Set 03/02/10 Permit Set SHEET REVISIONS: 01125110 1 Misc. Coordination EDITED BY: U ? PROJECT NO. 09-2587 z t� 0 Architectural Site Plan U y W z u, .............. ......................... . U w U D! ry A2.01 0 LL SHEET NOTES A REFER TO SHEET A19.31 FOR GENERAL FOUNDATION NOTES FO UME Hinae Elevation Hinae Detail Plan Rear Elevation 3"=1'-0" 3"=1'-0" 1 /4"=1'-0" wow Left Elevation Riaht Elevation 36'-8" B REFER TO CIVIL DRAWINGS FOR CONTINUATION OF CONCRETE SIDEWALK OR PAVEMENT C ALL DIMENSIONS TO BE VERIFIED W/ TRASH COMPACTOR VENDOR PRIOR TO CONSTRUCTION D VERIFY RAMP & STEP ELEVATION REQUIREMENTS W/ CIVIL DRAWINGS E REFER TO SHEET S19.33 FOR STRUCTURAL PLANS & DETAILS F ALL COLORS TO BE SELECTED BY OWNER 0 KEY NOTES 91-41' 01 TRASH COMPACTOR TO BE INSTALLED BY OTHERS, CONTRACTOR SHALL SUPPLY REQUIRED ELECTRICAL, CONNECTIONS & STRUCTURAL FASTNERS PER MFR's SPECIFICATIONS, VERIFY COMPACTOR MFR PRIOR TO COMMENCEMENT OF CONSTRUCTION 02 1/2" FIBER REINFORCED TEXTURED CEMENT PLASTER W/ SAND FINISHED ACCENT BANDS AS SHOWN 03 1 1/2" THICK FIBER REINFORCED CEMENT PLASTER SAND FINISHED ACCENT BAND, SLOPE TOP TOWARDS OUTSIDE 0'-0" 04 PAINTED CMU ON INSIDE 1 /4"=1'-0" 1 /4"=1'-0" 7'-0" 281-8" ... fA e `— 6 19.3 04 4 -0'-31 /2" S19.33 -0'-0" 01 SLOPE 0 1'-8" i— N 1 1-011 if on 2'-2" fit -loll 8'-0" 6'-8" 12'-0" 4 1'-6" SLOPE UP 3,-6 4 O01�y 16 `- 0'-0" 0'-0" 05 06 4 SLOPE UP 13'-11" 12'-0" 6'-0" 31'-11" 05 1 1/2" STEEL HANDRAIL 06 STEEL GUARDRAIL W/ PICKETS TOP RAIL @ 42" AFF, BOT RAIL @ 2" MAX AFF, PICKET MAX SPACING 4" 07 TRASH COMPACTOR CONTROLS, TOP OF CONTROLS @ 48" MAX 08 6" DIA CONCRETE FILLED 42" BOLLARD, SEE SHEET S19.33 FOR FOOTING DETAILS 09 PT 2x6 10 PT 1 X6 11 3/4" DIA ANCHOR BOLT, 5" MIN EMBED INTO FILLED CELL 12 1/4"xl"x4" STEEL ANGLE GATE FRAME 13 3/8" STEEL PLATE 14 1" OD PIPE SLEEVE 15 3/4" OD PIN 16 REQUIRED 60" DIA TURNING SPACE 17 CANE BOLT, PROVIDE SLOTS IN SLAB @ OPEN & CLOSE POSITIONS 18 INDUSTRIAL GRADE STEEL WHEELS 19 STAINLESS STEEL LATCH 20 CHUTE DOOR W/ HANDLE @ 48" AFF MAX 0 0 0. 0 a ARCHITECTURE & INTERIOR DESIGN, INC. PLANNING I ARCHITECTURE I INTERIOR DESIGN 745 orienta avenue, suite 1121 altamonte springs, fl 32701 phone: 407.830.1400 fax: 407.830.4143 AA0002731 www.forumarchitecture.com Meetinghouse at Zephyrhills Senior Apartments City of Zephyrhills, FL SET ISTRIBUTIONS: EDITED BY: PROJECT NO. 09-2587 Front Elevation 1 /4"=1'-0" Trash Compactor Enclosure Floor Plan 1 /4"=1'-0" Al 9,32 0 DESIGN CRITERIA PER CODE (MINIMUM) 0 SHEET NOTES 00 v a� a L0 u; �o o) 0 0 N a 0 -o m 0 0'-0" BOT. OF STAIR SLOPE Wall Cap Detail Section 1 1 /2"= V-0" 5 S19.33 r T Section� Side Wall 1'-6" LANDING 3/4"=1'-0" 0 b 0 CV 30" Section Across Ram 1'-0"01 8'-011 I -v 28'-8" BASIC WIND VELOCITY IMPORTANCE FACTOR EXPOSURE CATEGORY INTERNAL PRESSURE COEFFICIENT VELOCITY PRESSURE = 110 MPH A REFER TO SHEET A19.31 FOR GENERAL FOUNDATION = 0.77 NOTES =C = 0.0 B REFER TO CIVIL DRAWINGS FOR CONTINUATION OF = 17.23 PSF CONCRETE SIDEWALK OR PAVEMENT C ALL DIMENSIONS TO BE VERIFIED W/ TRASH DESIGN CRITERIA FOR PROJECT COMPACTOR VENDOR PRIOR TO CONSTRUCTION BASIC WIND VELOCITY = 140 MPH IMPORTANCE FACTOR = 1.0 D VERIFY RAMP & STEP ELEVATION REQUIREMENTS W/ CIVIL DRAWINGS EXPOSURE CATEGORY = C INTERNAL PRESSURE COEFFICIENT = 0.0 VELOCITY PRESSURE = 27.91 PSF ■ KEY NOTES NOTE: COMPONENTS & CLADDING FOR OPEN 01 6" CONCRETE SLAB REINFORCED AS NOTED, PLACE STRUCTURE SAME AS MAIN WIND FORCE. RESISTING SLAB OVER WELL COMPACTED FILL, BROOM FINISH SYSTEM USE: +35.3 PSF/ 47.3 PSF. FOR COMPONENTS & ALL SLAB SURFACES 3000 PSI @ 28 DAYS CLADDING ADD FACTOR AS REQ'D. 02 CONCRETE APRON: EXTEND SLAB BEYOND ENCLOSURE AS REQUIRED BY TRASH COMPACTOR VENDOR 3/4"=1'-0" 03 6" DIA., CONCRETE FILLED, STL PIPE BOLLARD, W/ 24"x24"x24" POURED FOOTING W/ #5 @ 12" OC EACH WAY TOP & BOTTOM, VERIFY LOCATIONS 04 EXTENDED BOTTOM OF ALL FOUNDATIONS AT PERIMETER 24" MIN BELOW FINISHED GRADE 05 16" WIDE THICKENED EDGE WI (2) #5 REBAR, CONT 06 #5 REBAR @ 12" OC, EA WAY, UNO 07 (2) #5 REBAR, @ BOT, CONT., #3 STIRRUP @ 16" OC 08 #5 REBAR @ 12" OC EACH WAY, LOCATE AT MIDSLAB 09 WWF 6x6-W2.9xW2.9 10 8" CMU WALL 11 #5 REBAR VERITCAL @ FILLED CELLS, 16" OC TYP AND @ CORNERS, CENTER REBAR IN CELLS 12 DURAWALL LADDER TYPE REINFORCEMENT, 16"OC 13 CONT BOND BEAM W/ (2) #5 REBAR 14 5" CONCRETE SLAB REINFORCED AS NOTED, PLACE SLAB OVER WELL COMPACTED FILL, BROOM FINISH ALL SLAB SURFACES 3000 PSI @ 28 DAYS 15 STEEL GUARDRAIL W/ PICKETS, TOP RAIL @ 42" AFF, BOT RAIL @ 2" MAX AFF, PICKET MAX SPACING @ 4" OC 16 1 1/2" STEEL HANDRAIL @ 36" AFF 17 PAINTED CMU INSIDE 18 #3 STIRRUPS @ 12" OC 19 1/2" PRE -MOLDED JOINT FILLER ROD 20 1/2" FIBER REINFORCED TEXTURED CEMENT PLASTER W/ SAND FINISHED ACCENT BANDS AS SHOWN 21 1 1/2" THICK FIBER REINFORCED SAND FINISHED ACCENT BAND, SLOPE TOP TOWARDS OUTSIDE 22 1/8" HARD POLYMER KOROLATH SHIM SIZED TO CONNECTION 23 5'-0" PRECAST CONC LINTEL 24 #3 STIRRUPS @ 16" OC 25 #5 BAR (TYP) LEGEND - — - — - - EDGE OF FOOTING BELOW EDGE OF SLAB ❑ GROUTED CELL 1"TA McL;kTen NEERING �11=111'y� GROUP �q1 014P FL CofA #7992 5728 Major Blvd., Suite 603, Orlando, FL 32819 Tel. (407) 354-5411 Fax (407) 354-3466 Web Site: www.mgmclaren.com FORUME ARCHITECTURE & INTERIOR DESIGN, INC. PLANNING I ARCHITECTURE I INTERIOR DESIGN 745 orienta avenue, suite 1121 altamonte springs, 11132701 phone: 407.830.1400 fax: 407.830.4143 AA0002731 www.forumarchitecture.com Meetinghouse at Zephyrhills Senior Apartments City of Zephyrhills, FL SET DISTRIBUTIONS: EDITED BY: PROJECT NO. 09-2587 Section at Stairs 3/4"=1'-0" Trash Compactor Enclosure Foundation Plan 1 /4"=1'-0" U F. Oleck FL PE #5251 S19-33 FORUME PLUMBING FIXTURE / EQUIPMENT SCHEDULE MARK FIXTURE SOIL/ WASTEHB-1 VENT COLD WATER HOT WATER �� MODEL DESCRIPTION HOSE BIBB — — 3/4' — WOODFORD #24 t— WITH LOOSE KEY. NOTE: ALL FIXTURES SHALL COMPLY WITH TABLE 604.4 OF THE FLORIDA PLUMBING COIF FOR WATER CONSERVATION. SHUT—OFF VALVE IN VALVE BOX 3/4' WATER; SEE CIVIL ._"ils — DRAWINGS FOR CONTINUATION. I I - I ._.._.........................._......................................_...............,......, f.....::.:.....:.........................:.::: ...., /(0 JOSE R. UZASOAIN—FL60785 SGM ENGINEERING, INC. M E P C O N S U L T I N G E N GI N E E R S 935 Lake Baldwin Lane TEL-(407) 767-5188 Baldwin Park FAX:(407) 767-5772 Orlando, Florida 32814 is (As EB_00006208 Project number. 29122 www.egmenginearing.com Copyright c 2009 SGM Engineering, Inc. ARCHITECTURE & INTERIOR DESIGN, INC. PLANNING I ARCHITECTURE I INTERIOR DESIGN 745 orients avenue, suite 1121 altamonte springs, fl 32701 phone: 407.830.1400 fax: 407.830.4143 AA0002731 www.forumarchitecture.com Meetinghouse at Zephyrhills Senior Apartments City of Zephyrhills, FL SFT DISTRIRIITIONS: 0 SHEET REVISIONS: EDITED BY: PROJECT NO. 09-2587 Trash Compactor Enc­1111losure .Plumbinq....Pla.n.. P 19.34 LIGHTING FI3ffURE SCHEDULE TYPE DESCRIPTION VOLTAGE LAMPS REMARKS EXTERIOR LANTERN 120 1- P w TRASH COMPACTOR wm., ... µX COORDINATE LOCATION OF CONTROL CONTROL ; PANEL AND DISCONNECT WITH r,J 'T' PANEL T (NEMA 3R) SEKV C E 120/208V-30-4W MINIMUM BREAKER AIC 42,000 LO r A -p 0 NEXTERIOR OF COMPACTOR RATING 100 AMP, MCB M O U N I NO SURFACE BKR KVA CKT. KVA BKR LOAD DESCRIPTION N. LOAD DESCRIPTION TRIP POLES •A •B OC 4A 0B 0C TRIP POLES E-TRASH COMPACTOR 60 3 3.9 1 2 0.2 20 1 L-LIGHTS 1 E- - - 3.9 3 41 0.5 20 1 L-SITE LIGHTING (1) E- - - 3.9 5 6 0.4 20 1 S-SPARE SPACE - - - 7 8 - - - SPACE SPACE - - - 9 10 - - - SPACE SPACE - - - 11 12 - - - SPACE j •-.- a -� -y t - fX. SI 1 t `` + z � z. rt zr.1 is; t-. �..-..�..�..:� .-�^=_�,.-..-.-.,7 �.. ",�.-a,.+ 4++.sy ..X. Y +s,+ -r ,.,u,-f 7 t'^ - ,�•,-=y'.,..---•f•--}---:,-y �'?`i---.--F-.`T•-� ..t.--.�-,..-� .d--�'--"7 "f=3. ,---'7i--t= q..�,--,•�,-'-L X. `!�. '`.r�..+�r...,�,' Ty rr w.-. r % r f'Ii'"Ny,-.r. 1 "'r '1iT.. ,'�'as .^'. .. �- + 77 77,777. E , 71777 , .,. _. 6 Iv��74v I _ ` h f y1 1 € - 77,77 1 k y TOTALS 3.9 3.9 3.9 0.2 0.5 0.4 SERVES CONN. LOAD - KVA D.F. CALC. DEMAND - KVA NOTES: (1) PHOTOCELL CONTROLED LIGHTING 0.70 1.25 0.88 RECEPTACLES - 1ST 10 KVA 0.00 1.0 0.00 RECEPTACLES - ABOVE 10 KVA 0.00 0.50 0.00 MECHANICAL 0.00 1.00 0.00 EQUIPMENT 11.70 1.0 11.70 APPLIANCE 0.00 0.75 0.00 SPARE/SPACE 0.40 1.0 0.40 OTHER 0.00 1 1.0 1 0.00 TOTALS 12.80 1 1 12.98 CALCULATED AMPS:36 UTI UTY S ERVICE) �.w.r. T ELECTRICAL RISER - COMPACTOR (SEA) _ SGM ENGINEERING, INC. M E P C O N S U L T I N G E N G I N E E R S 935 Lake Baldwin Lane TEL: (407) 767-5188 Baldwin Park FAX:(407) 767-5772 J Orlando, Florida 32814 EB-00006208 / i;c Project number. 29122 I/ www.agmengineering.com NE OR D M/R�TI'NOEZ-FI-611756 Copyright c2009 SGM Engineering, Inc. ARCHITECTURE & INTERIOR DESIGN, INC. ' PLANNING I ARCHITECTURE I INTERIOR DESIGN 745 orienta avenue, suite 1121 altamonte springs, fl 32701 phone: 407.830.1400 fax: 407.830.4143 AA0002731 www.forumarrhitecture.com Meetinghouse at Zephyrhills Senior Apartments City of Zephyrhills, FL 0 SHEET REVISIONS: EDITED BY: z PROJECT NO. 09-2587 -772 11 0