Senior Apartments
Picnic Pavilion
Owner. FINLAY INTERESTS 13, LTD.
The Brandywine Center I.
580 Village Boulevard, Suite 360 I West Palm Beach . Florida . 33409
P: 561.242.4814 I F: 561.242.5304
Architect. FORUM ARCHITECTURE & INTERIOR DESIGN, INC.
745 Orienta Avenue. Suite 1121 I Altamonte Springs . Florida . 32701
P: 407.830.1400 I F: 407.830.4143 I E: jchue@forumarchitecture.com
Structural Engineer . MCLAREN ENGINEERING GROUP
5728 Major Boulevard, Suite 603 I Orlando . Florida. 32819
P: 407.354.54111 F: 407.354.5411 I E: roleck@mgmclaren.com
P.M.E. Engineer. SGM ENGINEERING, INC.
935 Lake Baldwin Lane I Orlando. Florida. 32814
P: 407.767.5188 I F: 407.767.5772 I E: victor@sgmengineering.com
Zephyrhills, FL
12/17/09 Bid Set
01/25/10 Misc. Coordination
03/02/10 Permit Set
............................. ;.................................-
FORUME
ARCHITECTURE &
INTERIOR DESIGN, INC.
PLANNING I ARCHITECTURE I INTERIOR DESIGN
745 orienta avenue, suite 1121
altamonte springs, fl 32701
phone: 407.830.1400
fax: 407.830.4143
AA0002731
www.forumarchitecture.com
Meetinghouse
at Zephyrhills
Senior
Apartments
City of Zephyrhills, FL
0
i PROJECT NO. 09-2587
z
c�
N
O
o Picnic Pavilion
W Title Sheet,
Z Drawing Index
LU
& Issue History
..............
U
w
x
0
Al 9,60
0
LL
0
WOOD STRUCTURAL PANEL (PLYWOOD) N FOUNDATION M GENERAL CODES
01 PLYWOOD USED FOR ROOF SHEATHING SHALL BE 5/8" APA RATED SHEATHING, EXP.1, APA IDENTIFICATION 01 FOUNDATIONS HAVE BEEN DESIGNED TO AN ALLOWABLE SOIL BEARING PRESSURE OF 2,000 PSF. SHOULD 01 CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLYING WITH ALL APPLICABLE CODES AND MUST NOTIFY FLORIDA BUILDING CODE - BUILDING 2007 W/ APPLICABLE SUPPLEMENTS
INDEX 32/16, OR BETTER. CONDITIONS VARY FROM THE ASSUMED, THE ARCHITECT SHALL BE NOTIFIED BEFORE CONTINUATION OF ARCHITECT OF DISCREPANCIES INDICATED BY THESE DOCUMENTS FOUND DURING BIDDING AND PRIOR TO FLORIDA FIRE PREVENTION CODE 2007 EDITION
WORK. PROCEEDING WITH THE WORK. NATIONAL ELECTRIC CODE 2008 EDITION
FORUME
02 PLYWOOD SHALL BE NAILED TO JOISTS AS PER ROOF FASTENING ZONE PLAN.
03 USE PLYCLIPS OR OTHER EDGE SUPPORTS FOR ALL PLYWOOD SHEATHING.
04 PLACE FACE GRAIN IN DIRECTION OF SPAN (TRANSVERSE TO JOIST OR TRUSS SPAN).
05 LEAVE 1/16" SPACE AT ALL PLYWOOD PANEL END JOINTS AND 1/8" SPACE AT ALL PANEL EDGE JOINTS.
MICROLL.AM® OR PARALLAMO BEAMS
01 MICROLLAMO OR PARALLAMO BEAMS ARE INDICATED ON DRAWINGS AS:LVL OR PSL.
02 MICROLLAMO BEAMS SHALL HAVE THE FOLLOWING MINIMUM PROPERTIES:
E =
1.9X10"6PSI
FB
= 2,600 PSI
FT
= 1,555 PSI
FC
= 750 PSI
FC, PARALLEL
= 2,510 PSI
FV
= 285 PSI
03 BEAMS MUST BE LATERALLY SUPPORTED AT TOP.
04 MINIMUM BEARING LENGTH SHALL BE MINIMUM OF 1-1/2" AT ENDS AND 3-1/2" AT INTERMEDIATE SUPPORTS.
05 MULTIPLE MEMBERS SHALL BE FASTENED TOGETHER IN ACCORDANCE WITH MANUFACTURER'S
SPECIFICATIONS.
TRUSSES
01 SHOP DRAWINGS SHALL BE SUBMITTED FOR APPROVAL OF ALL WOOD TRUSSES.
02 SHOP DRAWINGS SHALL SHOW CHORD AND WEB SIZES, STRENGTHS, STIFFENERS (AS REQUIRED), BEARING
DETAILS, BRIDGING, BRACING, ERECTION NOTES AND DESIGN CALCULATIONS. TRUSSES SHALL BE DESIGNED
TO MEET THE DESIGN LOADS SHOWN ON THE STRUCTURAL NOTES AND PLANS. MAXIMUM LIVE LOAD
DEFLECTION SHALL BE LESS THAN 1/240 OF THE SPAN. MAXIMUM DEFLECTION UNDER FULL DESIGN LOAD
SHALL BE LIMITED TO 1/180 OF THE SPAN.
03 ALL SHOP DRAWINGS, ERECTION DRAWINGS AND CALCULATIONS SHALL BEAR THE SEAL AND SIGNATURE OF A
PROFESSIONAL ENGINEER LICENSED IN THE STATE OF THIS PROJECT.
04 LATERAL BRACING OF WEB MEMBERS SHALL INCLUDE A DIAGONAL BRACE (2" THICK NOMINAL) AT SPACING
NOT TO EXCEED 20 FEET. ALL END BAYS SHALL BE DIAGONALLY BRACED.
05 BOTTOM CHORDS OF WOOD TRUSSES SHALL BE CONTINUALLY BRACED AT A SPACING NOT TO EXCEED 10
FEET, LOCATED AT OR NEAR A PANEL POINT. DIAGONAL BRIDGING SHALL BE INSTALLED AT END BAYS AND IN
INTERMEDIATE BAYS AT 20 FEET SPACING.
06 THE TRUSS ERECTOR IS RESPONSIBLE FOR PROPER TRUSS HANDLING AND FOR TEMPORARY BRACING.
ERECTION BRACING SHALL BE APPLIED AS EACH TRUSS IS PLACED IN POSITION. CARE MUST BE TAKEN TO
STABILIZE THE FIRST TRUSS AND DIAGONAL BRACING IS NECESSARY TO AVOID PROGRESSIVE COLLAPSE.
02 ALL FOOTINGS SHALL BE PLACED DIRECTLY ON VIRGIN SOIL, OR CERTIFIED COMPACTED FILL.
03 CONCRETE FOR FOUNDATIONS:
A 28 DAY COMPRESSIVE STRENGTH FOR CONCRETE SHALL BE AS FOLLOWS:
FOOTINGS 3000 PSI
SLAB ON GRADE 3000 PSI
WALLS 3500 PSI
B MAXIMUM CONCRETE SLUMP SHALL BE 4".
C SLAB ON GRADE SHALL BE 5" THICK WITH WWF 6 x 6 -W1.4 x W1.4. SLAB SHALL BE FINISHED IN
ACCORDANCE WITH ACI STANDARD 302 FOR CLASS 2 FLOORS. IN LIEU OF WWF, SLAB ON GRADE MAY
CONSIST OF FIBER REINFORCED CONCRETE ACI 544.2R-89.
D ALL CONCRETE SHALL BE MIXED, TRANSPORTED AND PLACED IN ACCORDANCE WITH ACI STANDARDS
318, 304 AND 301.
E ALL REINFORCING BARS SHALL BE OF BILLET STEEL CONFORMING TO ASTM A615, GRADE 60.
F ALL WELDED WIRE MESH SHALL CONFORM TO ASTM A185.
G ALL VERTICAL SURFACES OF CONCRETE SHALL BE FORMED FOR WALLS AND FOOTINGS.
H REINFORCING STEEL SHALL BE PLACED TO PROVIDE THE FOLLOWING MINIMUM CONCRETE COVER:
SLAB ON GRADE 1-1/2"
WALLS 2"
FOOTINGS 3"
I GRADE BEAMS SHALL BE FORMED ON SIDES.
04 ALL FILL SHALL BE PLACED IN 8 INCH LOOSE LIFTS (MAXIMUM) COMPACTED WITH VIBRATORY ROLLERS. FILL
MATERIAL SHALL BE TESTED BY MODIFIED PROCTOR DENSITY METHOD (ASTM D1557) AND MUST QUALIFY AS
SELECT, WITH LESS THAN 10% PASSING THROUGH THE NO.200 SIEVE. SOIL SHALL BE PLACED WITH MOISTURE
CONTENT AND ENERGY TO PROVIDE 98% OF MAXIMUM DRY DENSITY BELOW SLABS ON GRADE, AND SOIL
SHALL BE COMPACTED TO 98% 12" AND 24" BELOW STRIP FOOTINGS AND COLUMN FOOTINGS, RESPECTIVELY.
IN PLACE DENSITY TESTS SHALL BE TAKEN FOR EACH 2,000 S.F. IN EACH LIFT. FOR ACCEPTANCE OF SOIL,
AVERAGE OF DENSITY TESTS MUST EXCEED THE SPECIFIED COMPACTION. NO TESTS SHALL BE PERMITTED
TO FALL BELOW 90% COMPACTION.
05 ALL EXTERIOR FOOTINGS SHALL BE PLACED A MINIMUM OF 2'-0" BELOW FINAL GRADE WHEN BEARING ON SOIL,
UNLESS NOTED OTHERWISE ON THE FOUNDATION DRAWINGS.
06 WHERE NECESSARY, FOOTING STEPS SHALL BE CONSTRUCTED AT MAXIMUM SLOPE OF 1 VERTICAL TO 2
HORIZONTAL.
07 WHERE ROCK OUTCROPPINGS ARE ENCOUNTERED IN A BUILDING FOUNDATION BEARING ON SOIL, SUCH
OUTCROPPING OR INTERFERENCE SHALL BE REMOVED TO A DEPTH 12 INCHES BELOW BOTTOM OF FOOTING
AND REPLACED WITH CLEAN GRANULAR MATERIAL CONTAINING LESS THAN 5% SILT, COMPACTED TO 95%
DENSITY PER MODIFIED PROCTOR METHOD. MAINTAIN A MINIMUM COVER OF 1'-6" TO BOTTOM OF CONCRETE
08 WHERE SOLID UNFRACTURED ROCK IS ENCOUNTERED FOR A WALL LENGTH OF AT LEAST 25 FEET, WALLS MAY
BE POURED WITHOUT FOOTINGS BY TRENCHING 6 INCHES INTO THE ROCK AND PINNING THE WALL TO ROCK
WITH #6 x T-0" LONG DOWELS AT 2'-8" ON CENTER, GROUTED INTO ROCK, EXTENDING V-6" INTO ROCK. NO
FROST PROVISIONS ARE REQUIRED FOR THIS DETAIL. PROVIDE CONTROL JOINT IN WALL AT ANY TRANSITION
BETWEEN ROCK BEARING AND SOIL BEARING CONDITIONS.
09 EXCAVATIONS SHALL BE DEWATERED TO A DEPTH OF AT LEAST 2 TO 3 FEET BELOW THE BOTTOM OF THE
EXCAVATIONS TO ALLOW INSTALLATION OF FOOTINGS IN DRY ATMOSPHERE.
10 DIFFERENTIAL BACKFILL AGAINST FOUNDATION WALLS SHALL NOT EXCEED FOUR FEET UNTIL TOP BRACING
OR FRAMEWORK HAS BEEN IN PLACE FOR A MINIMUM OF THREE DAYS. CANTILEVERED RETAINING WALLS MAY
BE BACK -FILLED WITHIN 14 DAYS OF CONCRETE PLACEMENT, BUT IN NO CASE SHALL DIFFERENTIAL OF
BACKFILL, BETWEEN OPPOSITE SIDES OF THE WALL, EXCEED THE FINAL DESIGN DIFFERENTIAL.
11 ALL BOTTOM OF FOOTING ELEVATIONS ARE SUBJECT TO CHANGE UPON INSPECTION OF SOIL CONDITION.
ELEVATION OF ADJACENT FOOTINGS SHALL VARY ON A SLOPE NOT STEEPER THAN ONE VERTICAL TO TWO
HORIZONTAL.
12 THE CONTRACTOR SHALL NOTIFY THE ENGINEER WHERE BOTTOM OF FOOTING ELEVATION IS CHANGED AND
OBTAIN REVISED DESIGN OF THE FOUNDATION AND RETAINING WALLS AS REQUIRED.
13 A MINIMUM 6-MIL POLYETHYLENE VAPOR BARRIER BETWEEN THE BOTTOM OF THE FLOOR SLAB AND THE TOP
OF THE COMPACTED SUBGRADE SHALL BE INSTALLED.
LUMBER
01 ALL NEW LUMBER SHALL BE VISUALLY GRADED LUMBER, SOUTHERN YELLOW PINE NO.2 OR BETTER WITH
MAXIMUM MOISTURE CONTENT OF 19% AND MINIMUM E=1,600,000 PSI IN ACCORDANCE WITH THE NATIONAL
DESIGN SPECIFICATION (NDS) FOR WOOD CONSTRUCTION.
02 ALL LUMBER SHALL BEAR VISIBLE GRADE STAMPING.
03 ALL JOISTS BEARING ON MASONRY SHALL BE FIRECUT WITH MINIMUM BEARING LENGTH OF FOUR INCHES.
04 EXCEPT AS UPGRADED ON PLANS OR DETAILS, ALL LUMBER SHALL BE NAILED IN ACCORDANCE WITH THE
NAILING SCHEDULE IN TABLE 2304.9.1 OF CHAPTER 23 OF THE 2007 FBC.
05 JOISTS SHALL BE FASTENED TO STEEL GIRDERS BY EITHER OF TWO ACCEPTABLE METHODS AS FOLLOWS
EXCEPT AS NOTED AT'TIMBER CONNECTIONS' BELOW:
i) A CONTINUOUS 2 x 6 NAILER PLATE SHALL BE BOLTED TO THE TOP FLANGE OF STEEL WITH 1/2 DIA.
STAINLESS STEEL BOLTS AT 4'-0" ON CENTER, ON ALTERNATE SIDES OF WEB. JOIST SHALL BE TOENAILED
TO PLATE WITH 3 8d NAILS PER JOIST. JOISTS FRAMING FROM OPPOSITE SIDES SHALL LAP AT LEAST SIX
INCHES, AND BE SPIKED TOGETHER AND BLOCKED.
II) A CONTINUOUS 2 x 4 NAILER PLATE SHALL BE BOLTED ABOVE THE BOTTOM FLANGE OF STEEL MEMBER
WITH 1/2 INCH DIAM. BOLTS AT 4'-0" ON CENTER. JOISTS SHALL BE NOTCHED ON TOP TO PROVIDE
CLEARANCE OF TOP FLANGE AND TO PROVIDE A SPACE OF AT LEAST 3/4" BETWEEN STEEL AND SUBFLOOR.
MAXIMUM DEPTH OF NOTCH SHALL BE 1/4 THE DEPTH OF JOIST. 20 GAGE METAL TIE OR WOOD SCAB SHALL
BE USED TO FASTEN OPPOSITE JOISTS TO ON ANOTHER.
02 DRAWINGS ARE DEVELOPED TO ILLUSTRATE SIZE, ASSEMBLY, RELATIONSHIP, QUANTITY, AND IDENTIFICATION
OF BUILDING COMPONENTS. DOCUMENTS WORK IN CONJUNCTION WITH SPECIFICATIONS REGARDING EXACT
REQUIREMENTS OF PRODUCTS, INSTALLATION QUALITY, STANDARD EXECUTION OF WORK, AND
CLASSIFICATIONS.
03 ALL TRADES MUST REVIEW ALL CONSTRUCTION DOCUMENTS AND ARE RESPONSIBLE FOR ALL WORK
ASSOCIATED WITH THEIR TRADES IN THESE DOCUMENTS. DO NOT BASE SCOPE OF WORK ONLY ON A REVIEW
OF THE SHEETS TYPICALLY ASSOCIATED WITH THE TRADE'S SCOPE OF WORK.
04 DO NOT SCALE DRAWINGS. USE ONLY PRINTED DIMENSIONS.
05 THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS, SHALL VERIFY EXISTING
TOPOGRAPHY AND GRADE ELEVATIONS, AND SHALL NOTIFY ARCHITECT OF ANY DISCREPANCIES PRIOR TO
PROCEEDING WITH THE PROJECT.
06 THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR AND HAVE CONTROL OVER CONSTRUCTION MEANS,
METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES, INCLUDING ALL SAFETY PRECAUTIONS AND
PROGRAMS, AND FOR COORDINATING ALL PORTIONS OF THE WORK.
07 ADDRESSES: APPROVED NUMBERS OR ADDRESSES SHALL BE PROVIDED FOR THE BUILDINGS SO THAT THE
NUMBERS OR ADDRESS IS PLAINLY VISIBLE AND LEGIBLE FROM THE STREET OR ROADWAY. THE NUMBERS
SHALL CONTRAST WITH THEIR BACKGROUND. ADDRESS NUMBERS SHALL BE DETERMINED BY THE OWNER.
08 DIMENSIONS SHOWN ARE TO FACE OF CONCRETE MASONRY UNITS, FACE OF STUD, MASONRY OPENING, OR
ROUGH OPENING AT STUD WALLS.
09 THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING AND SUBMITTING PRODUCT APPROVAL SHEETS AND DATA
TO THE BUILDING DEPARTMENT IN THE FORM THE BUILDING DEPARTMENT REQUIRES FOR ANY PRODUCT
SELECTION THAT IS CHANGED BY THE OWNER AND/OR THE CONTRACTOR FROM THE PRODUCT ORIGINALLY
SPECIFIED AND SUBMITTED BY THE ARCHITECT. THE CONTRACTOR MUST FIRST SUBMIT THE NEW PRODUCT
DATA TO THE ARCHITECT FOR REVIEW AND APPROVAL BEFORE SUBMITTING THE REQUIRED PRODUCT
APPROVAL SHEETS AND DATA TO THE BUILDING DEPARTMENT.
E GENERAL - SITE WORK
01 SOIL BEARING VALUES. FOUNDATION DESIGNS ARE BASED ON AN ESTIMATED SOIL BEARING VALUE OR
ACTUAL VALUE AS SPECIFIED BY A GEOTECHNICAL ENGINEER AND NOTED ON THE DRAWINGS. FOUNDATIONS
AND SLABS ARE DESIGNED TO UNIFORMLY BEAR ON WELL COMPACTED, WELL DRAINED NON -EXPANSIVE
SOILS. A CERTIFIED SOILS ENGINEER SHALL REVIEW FOUNDATION DESIGNS, BUILDING LOADS, AND COMPARE
WITH SUBSURFACE SOIL INVESTIGATION RECOMMENDATIONS. SHOULD ON -SITE OBSERVATIONS SHOW THAT
FOOTINGS SHOWN HERE ARE NOT SATISFACTORY, THE ARCHITECT SHALL BE CONTACTED IMMEDIATELY FOR
REVISED DESIGNS.
02 THE CONTRACTOR SHALL PROVIDE ALL OF THE FOLLOWING SITE REQUIRED ITEMS, BUT NOT LIMITED TO: SITE
UTILITIES, SLEEVES, CONDUIT, PULL BOXES, STRUCTURAL BASES, FOOTINGS, ETC. DESCRIBED OR REQUIRED
AS PART OF A COMPLETE SYSTEM ON CIVIL ENGINEERING, LANDSCAPE, SWIMMING POOL, ARCHITECTURAL,
STRUCTURAL, MECHANICAL, ELECTRICAL OR PLUMBING DRAWINGS. COORDINATE FULLY WITH ALL UTILITY
COMPANIES TO DETERMINE WHAT COMPONENTS ARE PROVIDED BY THE UTILITY COMPANIES. THE GENERAL
CONTRACTOR IS RESPONSIBLE FOR ALL ITEMS NOT SUPPLIED BY THE UTILITY COMPANY.
03 REFER TO CIVIL ENGINEERS SITE PLAN AND DETAILS FOR ACTUAL BUILDING LOCATIONS, FINISHED GRADES,
FLOOR ELEVATIONS, UTILITIES, DRAINAGE, ETC.
04 REFER TO LANDSCAPE ARCHITECT AND/OR POOL DESIGNER'S PLANS FOR LANDSCAPING, FENCES, POOL
DESIGN, IRRIGATION, EXTERIOR FURNISHINGS, TRAFFIC CONTROL, AND OTHER DECORATIVE LIGHT FIXTURES,
ETC,
05 CLEARANCE BETWEEN EXTERIOR WALL COVERINGS AND FINAL GRADE ON THE EXTERIOR OF BUILDING SHALL
NOT BE LESS THAN 6 INCHES, (U.N.O.)
06 NOTICE OF TERMITE PROTECTION. A PERMANENT SIGN WHICH IDENTIFIES THE TERMITE TREATMENT
PROVIDER AND NEED FOR REINSPECTION AND TREATMENT CONTRACT RENEWAL SHALL BE PROVIDED. THE
SIGN SHALL BE POSTED NEAR THE WATER HEATER OR ELECTRICAL PANEL.
GENERAL - STRUCTURAL
01 THESE STRUCTURAL PLANS HAVE BEEN PREPARED IN ACCORDANCE WITH THE APPLICABLE STRUCTURAL
CHAPTERS OF THE 2007 FLORIDA BUILDING CODE (FBC). ALL WORK SHALL BE PERFORMED IN ACCORDANCE
WITH THIS CODE AND ALL LOCAL REQUIREMENTS.
02 DESIGN LOADS:
A. SEE DESIGN CRITERIA ON STRUCTURAL DRAWING.
B. FLOOR LIVE LOADS HAVE BEEN REDUCED IN ACCORDANCE WITH CODE FOR GIRDERS AND COLUMNS.
C. WIND LOAD: SEE REQUIRED DESIGN WIND PRESSURES ON STRUCTURAL DRAWINGS.
D. COMPONENTS AND CLADDING: SEE REQUIRED DESIGN WIND PRESSURES ON STRUCTURAL DRAWINGS.
03 ALL WORK SHALL BE COORDINATED WITH ARCHITECTURAL, MECHANICAL, ELECTRICAL AND PLUMBING
DRAWINGS. CONFLICTS IN DIMENSION AND INTERFERENCE SHALL BE DIRECTED TO THE STRUCTURAL
ENGINEER PRIOR TO CONSTRUCTION OF WORK.
04 THE CONTRACTOR SHALL CHECK THE BUILDING LOCATIONS WITH REGARD TO PROPERTY LINE AND VERIFY
ALL EXISTING CONDITIONS PRIOR TO EXCAVATION AND SHOP DRAWING PREPARATION. NOTIFY THE
ARCHITECT / ENGINEER OF ANY DISCREPANCIES.
05 IN CASE OF CONTRADICTION BETWEEN THE DRAWINGS, THE SPECIFICATIONS AND THE CODES, OR IF ANY
CHANGE IS REQUIRED, THE CONTRACTOR SHALL INFORM THE ENGINEER IMMEDIATELY. NO CHANGE SHALL BE
MADE WITHOUT WRITTEN APPROVAL OF THE ARCHITECT I ENGINEER.
ACCESSIBILITY
IN ADDITION TO CODES LISTED ABOVE, ACCESS TO AND THROUGH THIS AMENITY IS
DESIGNED TO CONFORM TO THE FAIR HOUSING ACT OF 1988 AND AMENDMENTS AND
FLORIDA ACCESSIBILITY CODE.
SUMMARY
BUILDING TYPE NO. OF BLDGS. A/C AREA NON A/C AREA TOTAL AREA
PICNIC PAVILION 1 697 SF 697 SF
N CODE COMPLIANCE
OCCUPANCY TYPE U UTILITY
CONSTRUCTION TYPE V-B
AREA & HEIGHT LIMITATION (FBC-B TABLE 503): REQUIRED/ALLOWED PROPOSED
MEAN HEIGHT 40' 14A 0"
MAXIMUM NUMBER OF FLOORS 1 STORY 1 STORY
MAXIMUM AREA 5,500 SF 697 SF
FIRE PROTECTION (FBC-B TABLES 601 & 602):
INTERIOR BEARING WALLS
0 HR
0 HR
INTERIOR NON -BEARING WALLS
0 HR
0 HR
COLUMNS
0 HR
0 HR
BEAMS, GIRDERS & TRUSSES
0 HR
0 HR
FLOOR/CEILING ASSEMBLY
0 HR
0 HR
ROORCEILING ASSEMBLY
0 HR
0 HR
EXTERIOR BEARING WALLS
0 HR
0 HR
EXTERIOR NON -BEARING WALLS
0 HR
0 HR
d;
ARCHITECTURE &
INTERIOR DESIGN, INC.
PLANNING I ARCHITECTURE I INTERIOR DESIGN
745 orienta avenue, suite 1121
altamonte springs, fl 32701
phone: 407.830.1400
fax: 407.830.4143
AA0002731
www.forumarchitecture.com
Meetinghouse
at Zephyrhills
Senior
Apartments
City of Zephyrhills, FL
SET DISTRIBUTIONS:
EDITED BY: JT
z PROJECT NO. 09-2587
z
0
to
LU
Picnic Pavilion
R General Notes
w
& Code Compliance
w
U
W
F-
U
X
d0: A 19.61
0
LL
0
MAL-row
0
0
co
u
m
ro
n
0
0
6i
m
0
0
N
r-
a
0
0
a
Architectural Site Plan
MONUMENT SIGN (BY OTH
"�.. :.
WIRE ROAD
GARAGE
TRASH COMPACTOR II
ENCLOSURE
1 "=50'-0"
NORTH
0 SHEET NOTES
A REFER TO SHEET A1.03 FOR GENERAL NOTES
B REFER TO CIVIL PLANS FOR ALL SIDEWALK
LOCATIONS, HANDICAP PARKING AND ACCESSIBILITY
DETAILS, AND BUILDING LOCATIONS
C COORDINATE ENTRY GATE SYSTEM LOCATIONS AND
REQUIREMENTS WITH SYSTEM MANUFACTURER
D CONTRACTOR TO VERIFY CONDENSER PAD
LOCATIONS WITH SITE CONDITIONS
E FLORIDA YARDS 8 NEIGHBORHOOD CERTIFICATION IS
REQUIRED ON ALL LANDSCAPING.
0 LEGEND
BUILDING NUMBER
0X NO. OF UNITS
X X
BUILDING TYPE
LOCATION OF UFAS UNITS
N OF VISUAL / HEARINC
IMPAIRED UNITS
SITE PLAN HAS BEEN REVISED TO
COORDINATE WITH CIVIL DRAWINGS.
9
1
FORUME
ARCHITECTURE &
INTERIOR DESIGN, INC.
PLANNING I ARCHITECTURE I INTERIOR DESIGN
745 orients avenue, suite 1121
altamonte springs, fl 32701
phone: 407.830.1400
fax: 407.830.4143
AA0002731
www.forumarchitecture.com
Meetinghouse
at Zephyrhills
Senior
Apartments
City of Zephyrhills, FL
SET DISTRIBUTIONS:
11/25/09
Progress Sit.,
--- __
12/09/09
60% Prog
Set
12117109
Bid Set
03/02110
........................
Permit t
_........ _......................_................................................. _...........
SHEET REVISIONS:
01/25/10 1 Misc. Coordination
.........
EDITED BY:
U
i PROJECT NO. 09-2587
z
U
N
LU
Architectural Site Plan
E
w
z
.........................
w
U
w
U
0
A2.01
LL
N ASSEMBLIES
E SHEET NOTES
Co
n
W
U
U)
a
M
0
N
cu
M
0
N
ti
N
c
0
a�
0
a
rn
CV
m
11 '-0"
TRUSS BRG
1x6
1 x4
aTy
olumn Detail &a@.
olumn Detail
3/4"=1'-0" 6"=1'-0"p. @ All Columns Siding To Trim
Pavilion Reflected Ceiling Plan
1 /4"=1'-0"
U
a
a
21
22
Pavilion Elevation
Pavilion Roof Plan V-4"TYP.
23
1 /4"=1'-0"
1 /4"=1'-0"
1x4L04
E15
1 x8 04
q
in
N
TYPE/RATING
DESCRIPTION
0
TYP
NON RATED
FIBER CEMENT PANEL / TRIM BOARD OVER BUILDING WRAP
7/16" EXTERIOR GRADE WALL SHEATHING (15/32" P.T. PLYWD SHEATHING FIRST 4'
2x WOOD STUDS AT 16" OC
i
RC-1
TYP
NON RATED
30 YEAR ARCHITECTURAL FIBERGLASS 1 ASPHALT SHINGLES ON 30# FELT
5/8" CDX EXTERIOR GRADE SHEATHING
ROOF TRUSSES @ 24" OC
(1) LAYER 5/8" EXTERIOR GRADE GYPSUM SHEATHING
[:
MAY NOT BE REFERENCED ON THIS SHEET
A REFER TO SHEET Al9.61 FOR GENERAL NOTES
B ALL TRIM TO BE SMOOTH TEXTURE, ALL HORIZONTAL
LAP SIDING TO BE WOOD GRAIN TEXTURE
C ROOF SLOPE 6:12, LINO
D ALL FLASHING TO BE 26 GA. GALV. METAL, U.N.O.
M KEY NOTES
MAY NOT BE REFERENCED ON THIS SHEET
01 ROOF SYSTEM PER SPECS.
02 TYPICAL FASCIA TRIM: 2X8 ALUM. CLAD CONT.
FASCIA BOARD W/ ALUM. DRIP EDGE ABOVE @ ROOF
PERIMETER.
03 CONTINUOUS PERFORATED FIBER CEMENT SOFFIT
AT EAVE OVERHANG WITH INSECT SCREEN
04 FIBER CEMENT TRIM BOARD. PROVIDE FLASHING AS
NECESSARY
05 HEAVY DUTY PARK GRILL, MIRACLE #1104-8, SET IN
CONCRETE FOOTING AS PER MFR's SPECS
BUILDING TYPE: PP ATTIC SPACE:
06
ADA 46" SQUARE HEAVY DUTY ALL STEEL PICNIC
REQUIRED NFA VENTILATION
TABLE, HIGHLAND #166-1099, ANCHORED TO SLAB
Attic area (Including Soffit):
765 SF
NFA reqd (Attic Area / 150):
5.1 SF
07
46" SQUARE HEAVY DUTY ALL STEEL PICNIC TABLE,
Total reqd ventilation area in SI (Net Free Area X 144):
Upper portion reqd (Total Reqd Vent Area X 50%):
734.4 SI
367.2 Sl
HIGHLAND #166-1007, ANCHORED TO SLAB
Lower portion reqd (Total Reqd Vent Area - Upper Portion):
367.2 SI
PROVIDED NFA VENTILATION - UPPER
08
ALUM. GUTTERS & DOWNSPOUTS WHERE INDICATED
(3 ) 4 Ft Tamco Off -Ridge Vents X 138 SI/vent =
414 SI
PROVIDED NFA VENTILATION - LOWER
09
22"X36" ATTIC ACCESS PANEL
MFR: Hardie Model: Perforated Cement Board Soffit
Total soffit material to be used:
105 LF
10
12" ROUND DECORATIVE FOAM LOUVER
NFA of soffit material per LF:
5 / LF
Total provided:
525 SI
11
FLUSH MOUNT EXTERIOR LIGHT
12
FIBER CEMENT STARTER STRIP
10
19
13
ONE-PIECE CORNER TRIM: lx4x4
14
FIBER CEMENT PANEL
15 FIBER CEMENT HORIZONTAL LAP SIDING: 6"
12 EXPOSURE
01
16
CONT. SEALANT
02
17
METAL FLASHING
18
SELF ADHERING MEMBRANE
08
.......... _
03
19
FIBER CEMENT SHINGLE SIDING
20
OFF RIDGE VENT W/ INSECT SCREEN AS LISTED TO
13
MEET CODE
08
21
BUILDING WRAP
22
ROOFING FELT UNDERLAYMENT
23
ROOF SHINGLES
24
2X P.T. BLOCKING
Pavilion Elevation
1'-0"
11'-0"
Pavilion Floor Plan
1'-0"
37'-0 1 /2"
11'-0"
V-0"
12'-0 1 /2"
1 /4"=1'-0"
� rp
1 /4"=1'-0"
FORUME
ARCHITECTURE &
INTERIOR DESIGN, INC.
PLANNING I ARCHITECTURE I INTERIOR DESIGN
745 orienta avenue, suite 1121
altamonte springs, fl 32701
phone: 407.830.1400
fax: 407.830.4143
AA0002731
www.forumarchitecture.com
Meetinghouse
at Zephyrhills
Senior
Apartments
City of Zephyrhills, FL
SET DISTRIBUTIONS:
6 EDITED BY: JT
t
0
? PROJECT NO. 09-2587
z
U)
0
Picnic Pavilion
..................................................................................................................
Plans, Elevations
z & Details
....... ........
w
U
W
F-
I
U
Al 9.62
0
LL
0
E FOOTING SCHEDULE
co
d
N
0
Cal
R
O
0
N
a
0
0
0-
CM
v
M
01
� °DST
w�
a UL-A. ` CNN?
PER 02
S HED LE
footing Detail
@ Slab Edge
1/2"
SEE PLAN
2if� I 63
co
w f
z
02 PER
SCHEDULE
F-1
Footing Detail
@ Column
3/4"=1'-0"
SLOPE GRADE
EXTEND TURNDOWN AS
REQ. PER GRADING PLANS
TO MAINTAIN MIN. DEPTH
BELOW FIN. GRADE.
COORDINATE W/ CIVIL DWGS.
3/4"=1'-0"
FOUNDATION PLAN DIMENSIONED
TO EDGE OF CONC. SLAB, TYP.
FLOOR PLAN DIMENSIONED
TO FACE OF STUD, TYP.
MARK
SIZE
REINFORCEMENTS
COMMENTS
BOTTOM
TOP
L
W
D
SHORT BAR
LONG BAR
SHORT BAR
LONG BAR
F-1
36"
36"
38"
MIN.
#3 TIES
@ 24" O.C.
3 #5
---
1 #5
F-2
CONT.
12"
20"
---
1 #5
---
---
r— F-2 —�
I
I
I
I I
I I
I I
I IU;
LL
I
I I
5'-111/2"
I I
1 4'-111/2"
10
I C.J. -
F-2 F-2 �I
— JILL
u- LL L — J LL
IT-1 F-1 1
I
I
I
01 I
I
LL I I UL
1 a I
I O I
1 U)4-1 I
I
0'-0" I
CENTER f --J
ILL SLOPE SLOPE— LLI
F-1 1
F
I
I
w I
a-
0 I
04
I I
U. LL
I
I I
I
-1 1/4" 1 -1 F-1 E.O.S., TYP. F-11I
------------w LU---— — — — — — —ILLJ
F-2 F-2
10'-11"
25'-1"
0
tV
\*
-0'-0"
T.O.S. TYP
SHEET NOTES
MAY NOT BE REFERENCED ON THIS SHEET
A. REFER TO SHEET A19.61 FOR GENERAL FOUNDATION
NOTES
KEY NOTES
MAY NOT BE REFERENCED ON THIS SHEET
01. CONCRETE SLAB: 4" THICK MIN W/ 6X6 W1.4 X W1.4
WWF ON 6 MIL. VAPOR BARRIER LAP AND TAPE OVER
TERMITE TREATED, WELL COMPACTED SOIL. BROOM
FINISH ALL
02. FOUNDATION REINFORCEMENT PER SCHEDULE
03. 2X P.T. BOT. PLATE. W/ 1/2" x 10" ANCHOR BOLT @ 24"
OC OR AS SHOWN
= EGEND
— — — — — — EDGE OF FOOTING BELOW
EDGE OF SLAB
-P"'h'
IVATA wren
=ul=ul ��
�I=III= �/ ENGINEERING
�Il=0-1,V GROUP
FL CofA #7992
5728 Major Blvd., Suite 603, Orlando, FL 32819
Tel. (407) 354-5411 Fax (407) 354-3466
Web Site: www.mgmclaren.com
FORUME
ARCHITECTURE &
INTERIOR DESIGN, INC.
' PLANNING I ARCHITECTURE I INTERIOR DESIGN
745 orienta avenue, suite 1121
altamonte springs, fl 32701
phone: 407.830.1400
fax: 407.830.4143
AA0002731
www.forumarchitecture.com
Meetinghouse
at Zephyrhills
Senior
Apartments
City of Zephyrhills, FL
SET DISTRIBUTIONS:
EDITED BY: JT
PROJECT NO. 09-2587
Picnic Pavilion
............................
Foundation Plan &
Details
. ..... .....
Slab Edge Detail.
1 1 /2"=1'-0"
Pavilion Foundation Plan
1 /4"=1'-0"
Oleck FL PE #52514
S19,63
BEAM / HEADER ANCHORAGE ROOF DESIGN FACTORS
co
can
a
L0
N
0
N
ti
N
0
v
0
a
3
v
rn
J,11'-Q"
SS BRG.
IYI11 Y.
r,"""*Framing Detail
3/4"=1'-0"
� 1 1
Soffit Section
1 1 /2"21'-0"
1
111-01,
TRUSS BRG.
4
19.64
SHEET NOTES
MAY NOT BE REFERENCED ON THIS SHEET
HEADER SIZE HEADER TO SUPPORT STUDS
ROOF SLOPE
= 70<RS<270
UP TO 4'-0" (2) SIMPSON MSTA15 ((1) ON EACH SIDE)
L
= 20.1 FT
A.
REFER TO SHEET A19.61 FOR GENERAL FRAMING
4'-l" TO 8'-0" (2) SIMPSON MSTI26 ((1) ON EACH SIDE)
B
= 20.1 FT
NOTES
> 8'-1" (2) SIMPSON MSTI27 ((1) ON EACH SIDE)
EAVE
= 10.0 FT
MEDIAN ROOF HGT
= 13.5 FT
B.
REFER TO SHEET Al9.62 FOR ASSEMBLIES
BEAM / HEADER LEGEND
END ZONE STRIP
= 3.0 FT
VELOCITY PRESSURE
= 27.91 PSF
KE Y NOTES
TAG SIZE DESCRIPTION
B-1 (2)1 3/4"xl 1 7/8" LVL
MAY NOT BE REFERENCED ON THIS SHEET
B-2 (2) 2X12 SYP#2 W/ CONT. 7/16" FLITCH
ROOF ZONE WIND PRESSURE
01
CONCRETE SLAB: 4" THICK MIN. W/ 6X6 W1.4 X W1.4
ZONE AREA (SQ FT)
COEFFICIENT DESIGN PRESSURES (+l-)
WWF ON 6 MIL. VAPOR BARRIER LAP AND TAPE OVER
**FASTEN PLYS W/ 2 ROWS OF 16d NAILS @ 12" OC, EA. PLY
TERMITE TREATED, WELL COMPACTED SOIL. BROOM
BEAM /HEADER SUPPORT SCHEDULE
10
1.0
20.3
-32.3FINISH
ALL
20
1.0
18.5
-31.4
JACK STUDS KING STUDS
ZONE 1 50
100
1.0
1.0
16.1
14.3
-30.2
02
PREFAB GABLE END TRUSS W/VERTIC ALS @ 16" OC
HEADER SIZE PER SIDE PER SIDE REMARKS
-29.3
UP TO 4'-0" 1 1 UNO
> 100
1.0
14.3
-29.3
4'-1" TO 8'-0" 2 2 LINO
......... ....... 10
1.0
20.3
.
-56.2 .
03
2X P.T. BOT. PLATE. W/ 1/2" x 10" ANCHOR BOLT @ 24"
> 8'-111 3 3 UNO
20
1.0
18.5
-51.7
OC OR AS SHOWN
**MAINTAIN NUMBER OF VERTICAL MEMBERS FROM TOP
ZONE 2 50
1.0
16.1
-45.7
LEVEL TO FOUNDATION
100
1.0
14.3
-41.2
04
REFER TO SCHEDULE FOR STUD REQUIREMENTS @
> 100
1.0
14.3
41.2
EA. END OF BEAMS
ROOF TRUSS LOADING
10
1.0
20.3
-83.1
TCLL = 20
20
1.0
18.5
-77.7
05
PREFAB WD. ROOF TRUSSES @ MAX. 24" OC,
TCDL = 25
ZONE 3 50
1.0
16.1
-70.5
SIMPSON H5 @ EA TRUSS BRG., (1) SIMPSON MTS12
BCLL = - - -
100
1.0
14.3
-65.1
OR (2) SIMPSON H5 @ GIRDERS, ROOF PITCH AS
> 100
1.0
14.3
-65.1
NOTED ON PLAN
BCDL = 10
TOTAL = 55
USI = - - -
ROOF OVERHANG WIND PRESSURE
06
(2) SIMPSON H5 EACH TRUSS (2) MTS12 @ GIRDER
SPACING = 24" OC
ZONE AREA (SQ FT)
COEFFICIENT DESIGN
PRESSURES (+l-)
TRUSS TO DOUBLE TOP PLATE CONNECTION (UNLESS
OTHERWISE NOTED)
10
1.0
-65.7
4'-0" 4'-011 4'-011
20
1.0
-65.7
07
(2) SIMPSON LTSA24S EACH END OF BEAM TO STUDS
*4
ZONE 2 50
1.0
-65.7
(@ TOP OF COLUMN SECTION)
100
1.0
-65.7
3 __ 3 3
3 3 3
> 100
1.0
-65.7
08
SIMPSON HTT16 W/ 1/2" A.B. W/ 7" MIN. EMBEDMENT
_
10
1.0
-110.0
-1
20
1.0
-98.0
09
(2) X 1/2" ANCHOR BOLT.W/ 7" MIN. EMBEDMENT
O i
ZONE 3 50
1.0
-81.3
100
> 100
1.0
1.0
-68.7
10
DOUBLE TOP PLATE, TYP.
3
-68.7
4'-0"
PANELEDGES PANEL FIELD
O 10d NAILS @ 4" O.C. 10d NAILS @ 8" O.C.
Q 10d NAILS @ 4" O.C. 10d NAILS @ 6" O.C.
Q 10d NAILS @ 4" O.C. 10d NAILS @ 6" O.C.
NOTE: USE 10D RING SHANK NAILS IN ZONE 3 IF MEAN
ROOF HGT. IS GREATER THAN 25'
Roof Fastenina Zone Plan
Typical
1 /16"=l'-O"
WALL OPENING PRESSURE
ZONE AREA (SQ FT)
COEFFICIENT
DESIGN PRESSURES
10
1.0
35.3
-38.2
20
1.0
33.7
-36.7
ZONE 4 50
1.0
31.6
-34.6
100
1.0
30.0
-33.0
> 100
1.0
30.0
-33.0
10
1.0
35.3
47.2
20
1.0
33.7
44.0
ZONE 5 50
1.0
31.6
-39.8
100
1.0
30.0
-36.7
> 100
1.0
........ .........
30.0
-36.7
*IF AREA FALLS BETWEEN TWO VALUES INTERPOLATE OR USE
PRESSURES ASSOCIATED WITH
SMALLER AREA
STRAPPING SCHEDULE
UPLIFT REQ
CONNECTOR
MODEL NO.
MAX LOAD
0-775 LBS
(1) LTS12
775 LBS
775-1000 LBS
(1) MTS12
1000 LBS
1000-1455 LBS
(1) MTS12 + (1) H5
1455 LBS
1455-2000 LBS
(2) MTS12
2000 LBS
2000-2455 LBS
(2) MTS18 + (1) H5
2455 LBS
SINGLE -PLY GIRDER
(1) HTS20
1450 LBS
DOUBLE -PLY GIRDER
(2) HTS20
2900 LBS
11 46 KNEE BRACE
12 CONT. PERFORATED FIBER CEMENT SOFFIT AT ALL
EAVE OVERHANGS W/ INSECT SCREEN
13 2x8 ALUM CLAD CONT. FASCIA BOARD WI ALUM DRIP
EDGE
14 BEAM OR HEADER AS PER SCHEDULE ON FRAMING
PLANS. SEE STRUCTURAL FOR DETAILS
15 CONT. 2 X 4 BLOCKING (P.T. WHEN USED ON EXT.)
16 FIBER CEMENT TRIM BOARD
17 (4) 3l8" DIA. LAG SCREWS; 3" PENETRATION
18 SIMPSON HETA18 @ BOTTOM
19 ONE PIECE CORNER TRIM 1x4x4
20 FIBER CEMENT PANEL
21 FIBER CEMENT HORIZONTAL LAP SIDING
22 CONT. SEALANT
23 CONT. NON -PERFORATED FIBER CEMENT SOFFIT AT
GABLES
24 FIBER CEMENT SHINGLE SIDING
LEGEND
HEADER OR BEAM
WALLS BELOW
DESIGN CRITERIA PER CODE (MINIMUM)
BASIC WIND VELOCITY = 110 MPH
IMPORTANCE FACTOR = 0.77
EXPOSURE CATEGORY = C
INTERNAL PRESSURE COEFFICIENT = 0.0
VELOCITY PRESSURE = 17.23 PSF
WDESIGN CRITERIA FOR PROJECT
BASIC WIND VELOCITY = 140 MPH
IMPORTANCE FACTOR = 1.0
EXPOSURE CATEGORY = C
INTERNAL PRESSURE COEFFICIENT = 0.0
VELOCITY PRESSURE = 27.91 PSF
_P"6'
M1 •����Mcipren
11111111111NGINEERING
41=111''�� GROUP
FL CofA #7992
5728 Major Blvd., Suite 603, Orlando, FL 32819
Tel. (407) 354-5411 Fax (407) 354-3466
Web Site: www.mgmclaren.com
FORUME
L
0
0 ARCHITECTURE &
INTERIOR DESIGN, INC.
PLANNING I ARCHITECTURE I INTERIOR DESIGN
m
0
0 745 odenta avenue, suite 1121
altamonte springs, fl 32701
phone: 407.830.1400
06 fax: 407.830.4143
2 AA0002731
www.forumarchitecture.com
Meetinghouse
at Zephyrhills
Senior
Apartments
City of Zephyrhills, FL
EDITED BY: JT
PROJECT NO. 09-2587
Picnic Pavilion
... ......... ..... .
Framing Plan &
Details
Column Section
1 "=1'-0"
1 Pavilion Section
1 /2"=1'-0"
Pavilion Roof Framing Plan
1 /4"=1'-0"
4
R.F. Oleck FL FE #52514
S19-64
FORUME
+78'
C-15
0
LIGHTING FIXTURE SCHEDULE
TYPE
DESCRIPTION
VOLTAGE
LAMPS
REMARKS
A
EXTERIOR CEILING MOUNTED FIXTURE
WHITE ACRYLIC DIFFUSER
120
2—CFT13W
GX23
RATED FOR WET LOCATION
(SEAL)
-�
SGM ENGINEERING, INC.
MEP CONSULTING ENGINEERS
935 Lake Baldwin Lane TEL• (407) 767-5188
Baldwin Park FAX:(407) 767-5772
Orlando, Florida 32814
$ A* EB-00006208
J/ /
l
NESTOR D KMMNEZ—FL61756
Project number. 29122
www.agmengineering.com
Copyright a 2009 SGM Engineering, Inc.
ARCHITECTURE &
INTERIOR DESIGN, INC.
PLANNING I ARCHITECTURE I INTERIOR DESIGN
n
9 745 orienta avenue, suite 1121
u altamonte springs, fl 32701
phone: 407.830.1400
d fax: 407.830.4143
AA0002731
www.forumarchitecture.com
Meetinghouse
at Zephyrhills
Senior
Apartments
i
City of Zephyrhills, FL
i
SHEET REVISIONS:
EDITED BY:
E 19,65
1
A r
c4
,VOL alkn
14'