HomeMy WebLinkAbout38450 Valley Oaks Cir (2)ARCHITECTURAL SHEETS v M of cc 0 0 N N M G O lam' 1' ri1 Meetinghouse at Zephyrhills Senior Apartments Owner. FINLAY INTERESTS 13, LTD. The Brandywine Center I. 580 Village Boulevard, Suite 360 1 West Palm Beach. Florida . 33409 P: 561.242.4814 1 F: 561.242.5304 Architect . FORUM ARCHITECTURE & INTERIOR DESIGN, INC. 745 Orienta Avenue . Suite 1121 1 Altamonte Springs . Florida . 32701 P: 407.830.1400 1 F: 407.830.4143 1 E: jchue@forumarchitecture.com Structural Engineer. MCLAREN ENGINEERING GROUP 5728 Major Boulevard, Suite 603 1 Orlando . Florida . 32819 P: 407.354.54111 F: 407.354.5411 1 E: roleck@mgmclaren.com P.M.E. Engineer . SGM ENGINEERING, INC. 935 Lake Baldwin Lane I Orlando. Florida. 32814 P: 407.767.5188 1 F: 407.767.5772 1 E: victor@sgmengineering.com Pool Trellis Zephyrhills, FL 12/17/09 Bid Set 01/25/10 Misc. Coordination 03/02/10 Permit Set FORUME ARCHITECTURE & INTERIOR DESIGN, INC. PLANNING I ARCHITECTURE i INTERIOR DESIGN 745 orienta avenue, suite 1121 altamonte springs, fl 32701 phone: 407.830.1400 fax: 407.830.4143 AA0002731 www.forumarchitecture.com Meetinghouse at Zephyrhills Senior Apartments City of Zephyrhills, FL / Y / g N m � m O W W SET DISTRIBUTIONS: 12117109 Bid Set .................................................................... 03/02/10 Permit Set EDITED BY: JT Pool Trellis Title Sheet, Drawing Index & Issue History Al 9.50 CONCRETE MASONRY UNITS E FOUNDATION & GENERAL CODES 01 FOUNDATIONS HAVE BEEN DESIGNED TO AN ALLOWABLE SOIL BEARING PRESSURE OF 2,000 PSF. SHOULD CONDITIONS VARY FROM THE ASSUMED, THE ARCHITECT SHALL BE NOTIFIED BEFORE CONTINUATION OF WORK. 01. CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLYING WITH ALL APPLICABLE CODES AND MUST NOTIFY ARCHITECT OF DISCREPANCIES INDICATED BY THESE DOCUMENTS FOUND DURING BIDDING AND PRIOR TO PROCEEDING WITH THE WORK. FLORIDA BUILDING CODE - BULIDING 2007 W/ APPLICABLE SUPPLEMENTS FLORIDA FIRE PREVENTION CODE 2007 EDITION FORUME 01. ALL CONCRETE MASONRY UNITS SHALL BE HOLLOW LOAD BEARING UNITS CONFORMING TO ASTM C90, GRADE N, TYPE I, WITH MINIMUM COMPRESSIVE STRENGTH OF UNITS =1,900 PSI ON NET AREA, WITH ASSUMED DESIGN COMPRESSIVE STRENGTH, F'M =1,500 PSI. UNITS MAY BE FABRICATED EITHER WITH NORMAL WEIGHT AGGREGATE (C33) OR WITH LIGHTWEIGHT AGGREGATE (C331). 02. ALL UNITS SHALL BE PLACED IN RUNNING BOND. 03. MORTAR SHALL BE TYPE M OR S. MIX 1 PART PORTLAND CEMENT,1/4 TO 1/2 PART HYDRATED LIME AND 2-1/4 TO 3 PARTS SAND, MIXED ON SITE. 04. STORE ALL UNITS OFF GROUND TO PREVENT CONTAMINATION, COVER MATERIALS TO PROTECT FROM THE ELEMENTS. 05. NO AIR -ENTRAINING ADMIXTURES OR ANTIFREEZE COMPOUNDS, SUCH AS CALCIUM CHLORIDE SHALL BE ADDED TO MORTAR. 06. ALL WALLS OR PILASTERS SUPPORTING STEEL AT BEARING PLATES SHALL BE GROUTED SOLID FOR FOUR COURSES IN DEPTH FOR A WIDTH OF 32". 07. DO NOT BACKFILL AGAINST FOUNDATION WALLS UNTIL MORTAR HAS ATTAINED MAXIMUM STRENGTH. WHERE BACKFILL IS PLACED AGAINST FOUNDATION WALLS BEFORE FLOOR CONSTRUCTION IS IN PLACE, PROVIDE TEMPORARY BRACING. 08. THE FIRST BLOCK COURSE ON FOOTING SHALL BE FILLED SOLID WITH CONCRETE, UNLESS NOTED OTHERWISE IN DRAWINGS. 09. VERTICAL CONTROL JOINTS SHALL BE PLACED SUCH THAT THE RATIO OF JOINT SPACING (L) DIVIDED BY WALL HEIGHT (H) DOES NOT EXCEED 3.0. IN NO CASE SHALL SPACING EXCEED 50 FEET. CONTROL JOINTS SHALL BE CONSTRUCTED USING SASH BLOCKS AND DUR-O-WALL PREFORMED REGULAR RAPID CONTROL JOINT (OR EQUAL OF EXTRUDED RUBBER). WALL REINFORCING SHALL BE DISCONTINUOUS AT JOINTS. VERTICAL JOINTS SHALL BE LOCATED AS FOLLOWS: A. CHANGES IN WALL HEIGHT. B. AT CONSTRUCTION JOINTS IN FOUNDATION, IN ROOF AND IN FLOORS. C. AT CHASES AND RECESSES FOR PIPING, COLUMNS, FIXTURES, ETC. D. AT ABUTMENT OF WALL AND COLUMNS. E. AT RETURN ANGLES IN'L','T' AND'U' SHAPED STRUCTURES. F. AT ONE OR BOTH SIDES OF WALL OPENING. 10. CMU WALLS SHALL BE REINFORCED WITH TRUSS TYPE REINFORCING OF 9 GAGE ASTM A82 WIRE, GALVANIZED , AT 16" ON CENTER (VERTICALLY), AND AT THE FIRST AND SECOND BED JOINTS ABOVE AND BELOW WALL OPENINGS. 11. ALL MASONRY WALLS SHALL BE ADEQUATELY BRACED DURING CONSTRUCTION TO RESIST WIND LOADS OF 25 PSF. NOTE THAT FLOOR AND ROOF DIAPHRAGMS WILL PROVIDE ULTIMATE STABILITY FOR WALLS. UNTIL THESE ARE IN PLACE, MASONRY WALLS SHALL NOT BE BUILT HIGHER THAN 10 TIMES THEIR THICKNESS WITHOUT BRACING. a� U U) a u; 0 o) 0 0 N a 0 0 a 3 o� 02 ALL FOOTINGS SHALL BE PLACED DIRECTLY ON VIRGIN SOIL, OR CERTIFIED COMPACTED FILL. 03 CONCRETE FOR FOUNDATIONS: A 28 DAY COMPRESSIVE STRENGTH FOR CONCRETE SHALL BE AS FOLLOWS: FOOTINGS 3000 PSI SLAB ON GRADE 3000 PSI WALLS 3500 PSI B MAXIMUM CONCRETE SLUMP SHALL BE 4". C SLAB ON GRADE SHALL BE 5" THICK WITH WWF 6 x 6 -W1.4 x W1.4. SLAB SHALL BE FINISHED IN ACCORDANCE WITH ACI STANDARD 302 FOR CLASS 2 FLOORS. IN LIEU OF WWF, SLAB ON GRADE MAY CONSIST OF FIBER REINFORCED CONCRETE ACI 544.2R-89. D ALL CONCRETE SHALL BE MIXED, TRANSPORTED AND PLACED IN ACCORDANCE WITH ACI STANDARDS 318, 304 AND 301. E ALL REINFORCING BARS SHALL BE OF BILLET STEEL CONFORMING TO ASTM A615, GRADE 60. F ALL WELDED WIRE MESH SHALL CONFORM TO ASTM A185. G ALL VERTICAL SURFACES OF CONCRETE SHALL BE FORMED FOR WALLS AND FOOTINGS. H REINFORCING STEEL SHALL BE PLACED TO PROVIDE THE FOLLOWING MINIMUM CONCRETE COVER: SLAB ON GRADE 1-1/2" WALLS 2" FOOTINGS 3" 1 GRADE BEAMS SHALL BE FORMED ON SIDES. 04 ALL FILL SHALL BE PLACED IN 8 INCH LOOSE LIFTS (MAXIMUM) COMPACTED WITH VIBRATORY ROLLERS. FILL MATERIAL SHALL BE TESTED BY MODIFIED PROCTOR DENSITY METHOD (ASTM D1557) AND MUST QUALIFY AS SELECT, WITH LESS THAN 10% PASSING THROUGH THE NO, 200 SIEVE. SOIL SHALL BE PLACED WITH MOISTURE CONTENT AND ENERGY TO PROVIDE 98% OF MAXIMUM DRY DENSITY BELOW SLABS ON GRADE, AND SOIL SHALL BE COMPACTED TO 98% 12" AND 24" BELOW STRIP FOOTINGS AND COLUMN FOOTINGS, RESPECTIVELY. IN PLACE DENSITY TESTS SHALL BE TAKEN FOR EACH 2,000 S.F. IN EACH LIFT. FOR ACCEPTANCE OF SOIL, AVERAGE OF DENSITY TESTS MUST EXCEED THE SPECIFIED COMPACTION. NO TESTS SHALL BE PERMITTED TO FALL BELOW 90% COMPACTION. 05 ALL EXTERIOR FOOTINGS SHALL BE PLACED A MINIMUM OF 2'-0" BELOW FINAL GRADE WHEN BEARING ON SOIL, UNLESS NOTED OTHERWISE ON THE FOUNDATION DRAWINGS. 06 WHERE NECESSARY, FOOTING STEPS SHALL BE CONSTRUCTED AT MAXIMUM SLOPE OF 1 VERTICAL TO 2 HORIZONTAL. 07 WHERE ROCK OUTCROPPINGS ARE ENCOUNTERED IN A BUILDING FOUNDATION BEARING ON SOIL, SUCH OUTCROPPING OR INTERFERENCE SHALL BE REMOVED TO A DEPTH 12 INCHES BELOW BOTTOM OF FOOTING AND REPLACED WITH CLEAN GRANULAR MATERIAL CONTAINING LESS THAN 5% SILT, COMPACTED TO 95% DENSITY PER MODIFIED PROCTOR METHOD. MAINTAIN A MINIMUM COVER OF V-6" TO BOTTOM OF CONCRETE 08 WHERE SOLID UNFRACTURED ROCK IS ENCOUNTERED FOR A WALL LENGTH OF AT LEAST 25 FEET, WALLS MAY BE POURED WITHOUT FOOTINGS BY TRENCHING 6 INCHES INTO THE ROCK AND PINNING THE WALL TO ROCK WITH #6 x T-0" LONG DOWELS AT 2'-8" ON CENTER, GROUTED INTO ROCK, EXTENDING 1'-6" INTO ROCK. NO FROST PROVISIONS ARE REQUIRED FOR THIS DETAIL. PROVIDE CONTROL JOINT IN WALL AT ANY TRANSITION BETWEEN ROCK BEARING AND SOIL BEARING CONDITIONS. 09 EXCAVATIONS SHALL BE DEWATERED TO A DEPTH OF AT LEAST 2 TO 3 FEET BELOW THE BOTTOM OF THE EXCAVATIONS TO ALLOW INSTALLATION OF FOOTINGS IN DRY ATMOSPHERE. 10 DIFFERENTIAL BACKFILL AGAINST FOUNDATION WALLS SHALL NOT EXCEED FOUR FEET UNTIL TOP BRACING OR FRAMEWORK HAS BEEN IN PLACE FOR A MINIMUM OF THREE DAYS. CANTILEVERED RETAINING WALLS MAY BE BACK -FILLED WITHIN 14 DAYS OF CONCRETE PLACEMENT, BUT IN NO CASE SHALL DIFFERENTIAL OF BACKFILL, BETWEEN OPPOSITE SIDES OF THE WALL, EXCEED THE FINAL DESIGN DIFFERENTIAL. 11 ALL BOTTOM OF FOOTING ELEVATIONS ARE SUBJECT TO CHANGE UPON INSPECTION OF SOIL CONDITION. ELEVATION OF ADJACENT FOOTINGS SHALL VARY ON A SLOPE NOT STEEPER THAN ONE VERTICAL TO TWO HORIZONTAL. 12 THE CONTRACTOR SHALL NOTIFY THE ENGINEER WHERE BOTTOM OF FOOTING ELEVATION IS CHANGED AND OBTAIN REVISED DESIGN OF THE FOUNDATION AND RETAINING WALLS AS REQUIRED. 13 A MINIMUM 6-MIL POLYETHYLENE VAPOR BARRIER BETWEEN THE BOTTOM OF THE FLOOR SLAB AND THE TOP OF THE COMPACTED SUBGRADE SHALL BE INSTALLED. LUMBER 01. ALL NEW LUMBER SHALL BE VISUALLY GRADED LUMBER, SOUTHERN YELLOW PINE NO.2 OR BETTER WITH MINIMUM E=1,600,000 PSI IN ACCORDANCE WITH THE NATIONAL DESIGN SPECIFICATION 2005 (NDS) FOR WOOD CONSTRUCTION. 02. EXCEPT AS UPGRADED ON PLANS OR DETAILS, ALL LUMBER SHALL BE NAILED IN ACCORDANCE WITH THE NAILING SCHEDULE IN TABLE 2304.9.1 OF CHAPTER 23 OF THE 2007 FBC. 02. DRAWINGS ARE DEVELOPED TO ILLUSTRATE SIZE, ASSEMBLY, RELATIONSHIP, QUANTITY, AND IDENTIFICATION OF BUILDING COMPONENTS. DOCUMENTS WORK IN CONJUNCTION WITH SPECIFICATIONS REGARDING EXACT REQUIREMENTS OF PRODUCTS, INSTALLATION QUALITY, STANDARD EXECUTION OF WORK, AND CLASSIFICATIONS. 03. ALL TRADES MUST REVIEW ALL CONSTRUCTION DOCUMENTS AND ARE RESPONSIBLE FOR ALL WORK ASSOCIATED WITH THEIR TRADES IN THESE DOCUMENTS. DO NOT BASE SCOPE OF WORK ONLY ON A REVIEW OF THE SHEETS TYPICALLY ASSOCIATED WITH THE TRADE'S SCOPE OF WORK. 04, DO NOT SCALE DRAWINGS. USE ONLY WRITTEN DIMENSIONS. 05. THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS, SHALL VERIFY EXISTING TOPOGRAPHY AND GRADE ELEVATIONS, AND SHALL NOTIFY ARCHITECT OF ANY DISCREPANCIES PRIOR TO PROCEEDING WITH THE PROJECT. 06. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR AND HAVE CONTROL OVER CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES, INCLUDING ALL SAFETY PRECAUTIONS AND PROGRAMS, AND FOR COORDINATING ALL PORTIONS OF THE WORK. ACCESSIBILITY IN ADDITION TO CODES LISTED ABOVE, ACCESS TO AND THROUGH THIS AMENITY IS DESIGNED TO CONFORM TO THE FAIR HOUSING ACT OF 1988 AND AMENDMENTS AND FLORIDA ACCESSIBILITY CODE. IIIIIIIIIIIIIIISUMMARY BUILDING TYPE NO. OF BLDGS. A/C AREA NON A/C AREA TOTAL AREA POOL TRELLIS 1 128 SF 128 SF CODE COMPLIANCE OCCUPANCY TYPE U UTILITY CONSTRUCTION TYPE V-B AREA & HEIGHT LIMITATION (FBC-B TABLE 503): REQUIRED/ALLOWED PROPOSED MEAN HEIGHT 40' 11'-8" MAXIMUM NUMBER OF FLOORS 1 STORY 1 STORY MAXIMUM AREA 5,500 SF 128 SF 07. ADDRESSES: APPROVED NUMBERS OR ADDRESSES SHALL BE PROVIDED FOR THE BUILDINGS SO THAT THE FIRE PROTECTION (FBC-B TABLES 601 & 602): NUMBERS OR ADDRESS IS PLAINLY VISIBLE AND LEGIBLE FROM THE STREET OR ROADWAY. THE NUMBERS SHALL CONTRAST WITH THEIR BACKGROUND. ADDRESS NUMBERS SHALL BE DETERMINED BY THE OWNER. INTERIOR BEARING WALLS INTERIOR NON -BEARING WALLS 08. DIMENSIONS SHOWN ARE TO FACE OF CONCRETE MASONRY UNITS, FACE OF STUD, MASONRY OPENING, OR COLUMNS ROUGH OPENING AT STUD WALLS. BEAMS, GIRDERS & TRUSSES FLOOR/CEILING ASSEMBLY 09. THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING AND SUBMITTING PRODUCT APPROVAL SHEETS AND DATA ROORCEILING ASSEMBLY TO THE BUILDING DEPARTMENT IN THE FORM THE BUILDING DEPARTMENT REQUIRES FOR ANY PRODUCT EXTERIOR BEARING WALLS SELECTION THAT IS CHANGED BY THE OWNER AND/OR THE CONTRACTOR FROM THE PRODUCT ORIGINALLY EXTERIOR NON -BEARING WALLS SPECIFIED AND SUBMITTED BY THE ARCHITECT. THE CONTRACTOR MUST FIRST SUBMIT THE NEW PRODUCT DATA TO THE ARCHITECT FOR REVIEW AND APPROVAL BEFORE SUBMITTING THE REQUIRED PRODUCT APPROVAL SHEETS AND DATA TO THE BUILDING DEPARTMENT. MSITE WORK 01. SOIL BEARING VALUES. FOUNDATION DESIGNS ARE BASED ON AN ESTIMATED SOIL BEARING VALUE OR ACTUAL VALUE AS SPECIFIED BY A GEOTECHNICAL ENGINEER AND NOTED ON THE DRAWINGS. FOUNDATIONS AND SLABS ARE DESIGNED TO UNIFORMLY BEAR ON WELL COMPACTED, WELL DRAINED NON -EXPANSIVE SOILS. A CERTIFIED SOILS ENGINEER SHALL REVIEW FOUNDATION DESIGNS, BUILDING LOADS, AND COMPARE WITH SUBSURFACE SOIL INVESTIGATION RECOMMENDATIONS. SHOULD ON -SITE OBSERVATIONS SHOW THAT FOOTINGS SHOWN HERE ARE NOT SATISFACTORY, THE ARCHITECT SHALL BE CONTACTED IMMEDIATELY FOR REVISED DESIGNS. 02. THE CONTRACTOR SHALL PROVIDE ALL OF THE FOLLOWING SITE REQUIRED ITEMS, BUT NOT LIMITED TO: SITE UTILITIES, SLEEVES, CONDUIT, PULL BOXES, STRUCTURAL BASES, FOOTINGS, ETC. DESCRIBED OR REQUIRED AS PART OF A COMPLETE SYSTEM ON CIVIL ENGINEERING, LANDSCAPE, SWIMMING POOL, ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL OR PLUMBING DRAWINGS. COORDINATE FULLY WITH ALL UTILITY COMPANIES TO DETERMINE WHAT COMPONENTS ARE PROVIDED BY THE UTILITY COMPANIES. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR ALL ITEMS NOT SUPPLIED BY THE UTILITY COMPANY. 03. REFER TO CIVIL ENGINEERS SITE PLAN AND DETAILS FOR ACTUAL BUILDING LOCATIONS, FINISHED GRADES, FLOOR ELEVATIONS, UTILITIES, DRAINAGE, ETC. 04. REFER TO LANDSCAPE ARCHITECT AND/OR POOL DESIGNER'S PLANS FOR LANDSCAPING, FENCES, POOL DESIGN, IRRIGATION, EXTERIOR FURNISHINGS, TRAFFIC CONTROL, AND OTHER DECORATIVE LIGHT FIXTURES, ETC. 05. CLEARANCE BETWEEN EXTERIOR WALL COVERINGS AND FINAL GRADE ON THE EXTERIOR OF BUILDING SHALL NOT BE LESS THAN 6 INCHES, (U.N.O.) 06. NOTICE OF TERMITE PROTECTION. A PERMANENT SIGN WHICH IDENTIFIES THE TERMITE TREATMENT PROVIDER AND NEED FOR REINSPECTION AND TREATMENT CONTRACT RENEWAL SHALL BE PROVIDED. THE SIGN SHALL BE POSTED NEAR THE WATER HEATER OR ELECTRICAL PANEL. 0 GENERAL - STRUCTURAL 01. THESE STRUCTURAL PLANS HAVE BEEN PREPARED IN ACCORDANCE WITH THE APPLICABLE STRUCTURAL CHAPTERS OF THE 2007 FLORIDA BUILDING CODE. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THIS CODE AND ALL LOCAL REQUIREMENTS. 02. DESIGN LOADS: A. SEE DESIGN CRITERIA ON STRUCTURAL DRAWING. B. FLOOR LIVE LOADS HAVE BEEN REDUCED IN ACCORDANCE WITH CODE FOR GIRDERS AND COLUMNS. C. WIND LOAD: SEE REQUIRED DESIGN WIND PRESSURES ON STRUCTURAL DRAWINGS. D. COMPONENTS AND CLADDING: SEE REQUIRED DESIGN WIND PRESSURES ON STRUCTURAL DRAWINGS. 03. ALL WORK SHALL BE COORDINATED WITH ARCHITECTURAL, MECHANICAL, ELECTRICAL AND PLUMBING DRAWINGS. CONFLICTS IN DIMENSION AND INTERFERENCE SHALL BE DIRECTED TO THE STRUCTURAL ENGINEER PRIOR TO CONSTRUCTION OF WORK. 04. THE CONTRACTOR SHALL CHECK THE BUILDING LOCATIONS WITH REGARD TO PROPERTY LINE AND VERIFY ALL EXISTING CONDITIONS PRIOR TO EXCAVATION AND SHOP DRAWING PREPARATION. NOTIFY THE ARCHITECT 1 ENGINEER OF ANY DISCREPANCIES. 05. IN CASE OF CONTRADICTION BETWEEN THE DRAWINGS, THE SPECIFICATIONS AND THE CODES, OR IF ANY CHANGE IS REQUIRED, THE CONTRACTOR SHALL INFORM THE ENGINEER IMMEDIATELY. NO CHANGE SHALL BE MADE WITHOUT WRITTEN APPROVAL OF THE ARCHITECT / ENGINEER. 0 HR 0 HR 0 HR 0 HR 0 HR 0 HR 0 HR 0 HR 0 HR 0 HR 0 HR 0 HR 0 HR 0 HR 0 HR 0 HR 10 ARCHITECTURE & INTERIOR DESIGN, INC. PLANNING I ARCHITECTURE I INTERIOR DESIGN 745 orienta avenue, suite 1121 altamonte springs, fl 32701 phone: 407.830.1400 fax: 407.830.4143 AA0002731 www.forumarchitecture.com Meetinghouse at Zephyrhills Senior Apartments City of Zephyrhills, FL U M� m� ms U� w� Q 0 SAT DISTRIBUTIONS: EDITED BY: JT PROJECT NO. 09-2587 Pool Trellis General Notes & Code Compliance A19,51 Maximum Area of Exterior Wall Openings = SHEET NOTES Per Table 704.8 & Section 704.8.1 FBC 2007) A REFER TO SHEET A1.03 FOR GENERAL NOTES 0 0 cD n a� U) a 00 o� T M 0 0 N t` N C O d O a rn 3 0 N 0 rl- Go LO C O U Co N Architectural Site Plan MONUMENT SIGN (BY OTHERS) WIRE ROAD Building Side or Portion Distance To % Opening % Opening Building Type of Building Property Line Allowed Provided 1 1 Rear Elev. 19'-9" 75% 36% 4 III Right Elev. 10, 10% 6% 4 III Rear Elev. 21' 45% 30% 3 II Right Elev. 10'-6" 15% 6.5%° 3 II Rear Elev. 21'-0" 45% 34% 2 III _ Right Elev. 8'-10" 10% - 6% 2 III Rear Elev. 21' 45% 28% 1 1 Right Elev. 11 6-10" 1 1 25% ................ 19% GARAGE TRASH COMPACTOR II ENCLOSURE 1 "=50'-0" NORTH B REFER TO CIVIL PLANS FOR ALL SIDEWALK LOCATIONS, HANDICAP PARKING AND ACCESSIBILITY DETAILS, AND BUILDING LOCATIONS C COORDINATE ENTRY GATE SYSTEM LOCATIONS AND REQUIREMENTS WITH SYSTEM MANUFACTURER D CONTRACTOR TO VERIFY CONDENSER PAD LOCATIONS WITH SITE CONDITIONS E FLORIDA YARDS & NEIGHBORHOOD CERTIFICATION IS REQUIRED ON ALL LANDSCAPING. 0 LEGEND BUILDING NUMBER NCO.OF UNITS X X X BUILDING TYPE LOCATION OF UFAS UNITS :❖:❖: WORK, LOCATION OF VISUAL / HEARING IMPAIRED UNITS SITE PLAN HAS BEEN REVISED TO COORDINATE WITH CIVIL DRAWINGS. 9 1 FORUME ARCHITECTURE & INTERIOR DESIGN, INC. PLANNING I ARCHITECTURE I INTERIOR DESIGN 745 orienta avenue, suite 1121 altamonte springs, fl 32701 phone: 407.830.1400 fax: 407.830.4143 AA0002731 www.forumarchitecture.com Meetinghouse at Zephyrhills Senior Apartments City of Zephyrhills, FL 11009.... ; .., Progress. Set......._ 12109109 60% Progress Se 12/17/09 Bid Set 0310?110 ....................................................... Permit Set EDITED BY: PROJECT NO. 09-2587 Architectural Site Plan A2,01 co �r a. O N cu O O O N (D a 0 0 0 a. 3 v MW'l 0 I `D 2 �t 3x6 Rafter End Detail 4x8 Ridge Beam End Detail I -11L- 1� L 81/4" a co 3"=1'-0" 3"=1'-0" C'V Pool Trellis Elevation s �.52 1 /4"=1'-0" Z10 . _...... .......... _..... 10'-41/4" TRUSS BRG. I I 7 A19.52 I I 8 08 Al9.52 I I o'-0" POOL DECK Pool Trellis Elevation 1 /4"=1'-0" Pool Trellis Roof Plan BB---C% BB �11-4"� ■■ m ■ ■r2 e■p U* 1 /4"=1'-0" SHEET NOTES A REFER TO SHEET A19.51 FOR GENERAL NOTES B REFER TO POOL DRAWINGS FOR POOL DECK C APPLY CLEAR SEALANT TO ALL ROUGH SAWN CEDAR KEY NOTES 01 8" CMU COLUMN, ALTERNATE EACH COURSE 02 2x2 ROUGH SAWN CEDAR AT 12" OC 03 2x4 ROUGH SAWN CEDAR AT 16" OC 04 3x6 ROUGH SAWN CEDAR AT 24" OC 05 48 ROUGH SAWN CEDAR RIDGE BEAM 06 4xl2 ROUGH SAWN CEDAR TRELLIS BEAM 07 2x6 ROUGH SAWN CEDAR ON EACH SIDE OF RAFTER W/ (2)1 /2"0 THRU BOLTS 08 FIBER REINFORCED CEMENT PLASTER FINISH 09 GALV MTL TRAY AT BEAM CEMENT PLASTER THICKNESS LEGEND 0 1/2" REINFORCED CEMENT PLASTER 1 3/4" REINFORCED CEMENT PLASTER 2 1" REINFORCED CEMENT PLASTER 3 mFORUME M L 0 ARCHITECTURE & INTERIOR DESIGN, INC. q PLANNING I ARCHITECTURE I INTERIOR DESIGN 0 0 g 745 orienta avenue, suite 1121 altamonte springs, fl 32701 c phone: 407.830.1400 ad fax: 407.830.4143 AA0002731 www.forumarchitecture.com Meetinghouse at Zephyrhills Senior Apartments City of Zephyrhills, FL SET DISTRIBUTIONS: EDITED BY: JT PROJECT NO. 09-2587 Pool Trellis Plans, Elevations & Details ii . Column Detail 3/4"=1'-0" 4x12 Beam End Detail 3"=1'-0" Pool Trellis Floor Plan 1 /4"=1'-0" A 19,52 ROOF DESIGN CRITERIA SHEET NOTES 3 co n. M Cn M o) 0 0 N CEO a O 0 a Rafter to Beam Connection Ridge Beam Connection 1 1 /2"=1'-O" 1 1 /2"=1'-O" 48" 4 0 ROOF SLOPE = 70<RS<270 L = 11'-4" FT B = 11'4" FT EAVE = 9'4" FT MEDIAN ROOF HGT = 11'-13/8" FT END ZONE STRIP = 3.0 FT VELOCITY PRESSURE = 36.25 PSF ROOF ZONE WIND PRESSURE ZONE AREA (SQ FT) COEFFICIENT DESIGN PRESSURES 10 1.0 20.3 -32.3 20 1.0 18.5 -31.4 ZONE 1 50 1.0 16.1 -30.2 100 1.0 14.3 -29.3 > 100 1.0 14.3 -29.3 10 1.0 20.3 -56.2 20 1.0 18.5 -51.7 ZONE 2 50 1.0 16.1 -45.7 100 1.0 14.3 -41.2 > 100 1.0 14.3 41.2 10 1.0 20.3 -83.1 20 1.0 18.5 -77.7 ZONE 3 50 1.0 16.1 -70.5 100 1.0 14.3 -65.1 > 100 1.0 14.3 -65.1 WALL COMPONENTS & CLADDING PRESSURES ZONE AREA (SQ FT) COEFFICIENT DESIGN PRESSURES (+l- 10 1.0 35.3 -38.2 20 1.0 33.7 -36.7 ZONE 4 50 1.0 31.6 -34.6 100 1.0 30.0 -33.0 > 100 1.0 30.0 -33.0 10 1.0 35.3 -47.2 20 1.0 33.7 -44.0 ZONE 5 50 1.0 31.6 -39.8 100 1.0 30.0 -36.7 > 100 1.0 30.0 -36.7 `IF AREA FALLS BETWEEN TWO VALUES INTERPOLATE OR USE PRESSURES ASSOCIATED WITH SMALLER AREA I I I I I L- r- I I I L-----i L----J 4'-0" 6-0" 4'-0" 14'-0" A REFER TO SHEET A19.51 FOR GENERAL NOTES B REFER TO POOL DRAWINGS FOR POOL DECK KEY NOTES 01 CONC FOOTING wl (5) #5 REBAR EACH WAY, TOP & BOTTOM 02 #5 DOWEL AT EACH CORNER CELL 03 8" CMU COLUMN, ALTERNATE EACH COURSE 04 FILL ALL CELLS w/ 2,000 PSI GROUT & (1) #5 VERTICAL REBAR 05 2x2 ROUGH SAWN CEDAR AT 6" OC w/ (2)8d NAILS TO 2x4 06 2x4 ROUGH SAWN CEDAR AT 16" OC wl (2)12d NAILS TO 3x6 07 3x6 ROUGH SAWN CEDAR AT 24" OC 08 48 ROUGH SAWN CEDAR RIDGE BEAM 09 4x12 ROUGH SAWN CEDAR TRELLIS BEAM 10 2x6 ROUGH SAWN CEDAR ON EACH SIDE OF RAFTER w/ 1/2"0 THRU BOLTS 11 3/4"0 HEADER ANCHOR BOLT, 4" MIN EMBED 12 COUNTERSINK NUT & WASHER, GLUE & PLUG 13 SIMPSON MTS12 AT 2x6 BEAM TO RAFTER, INSTALL STRAP BETWEEN RAFTER & BEAM 14 GALV MTL TRAY AT BEAM, SEAL AT STUCCO w/ URETHANE SEALANT 15 1 "xl 8" GALV MTL STRAP, RAFTER TO RAFTER DESIGN CRITERIA PER CODE (MINIMUM) BASIC WIND VELOCITY = 110 MPH IMPORTANCE FACTOR = 1 EXPOSURE CATEGORY = C INTERNAL PRESSURE COEFFICIENT = 0.0 DESIGN CRITERIA FOR PROJECT BASIC WIND VELOCITY = 140 MPH IMPORTANCE FACTOR = 1.0 EXPOSURE CATEGORY = C INTERNAL PRESSURE COEFFICIENT = 0.0 ROOF TRUSS LOADING TCLL = 20 TCDL = 10 BCLL- BCDL = --- TOTAL = 30 _ • Mcip ren 11=111 �..I1-III= �^/ NGI -1NEERING �Il��illl Y GROUP FL CofA #7992 5728 Major Blvd., Suite 603, Orlando, FL 32819 Tel. (407) 354-5411 Fax (407) 354-3466 Web Site: www.mgmclaren.com DFORUME V r r 0 q ARCHITECTURE & INTERIOR DESIGN, INC. 01 PLANNING I ARCHITECTURE I INTERIOR DESIGN 745 orienta avenue, suite 1121 altamonte springs, fl 32701 phone: 407.830.1400 fax: 407.830.4143 AA0002731 www.forumarchkecture.com Meetinghouse at Zephyrhills Senior Apartments City of Zephyrhills, FL EDITED BY: 0 d r PROJECT NO. Pool Trellis Structural Plans & Details JT 09-2587 Rafter to Beam Section 1 1 /2"=1'-0" Column Section 3/4"=1'-0" Foundation Plan 1 /4"=1'-0" R.F. Oleck FL PE #52514 S19-53 pa/, Txe //� cN f6?- C- 0Py 11 4-5D �all( ,53 �(�Isa�tf�> POOL ,Z,O (D 1 .,