Loading...
HomeMy WebLinkAbout38512-38646 Valley Oaks CirVICINITY MAP s2 !%7 i country A l_,, t s81 f 52 Ode C,ty SUMTER 471 35A f"' I i...., ram,. 33 `x c P A 6 C a mi � r Jay a Starkey 41 ' W ilderness Parr .' Zeptlyrh(t9a-� SITE a k R 7 Lr:ar�Cy ku 54 �' .. Wiss Park - a Rev �d ;n a ( l L H O R O tJ �# kSRO 8ndP 'rr c � R on Park 1t 4 597 i F GreekTrots _od V-S S,kr nt SR a , - Pa 'VA.ferno' ark 5" "a � 582A 587 41 4 ilk �noicsassa x 5A a�.� A.� W ° Temple St�t,n "'� -----`-� Terrace ►ke+9 park 5b4«t 583579 <,., a ,98- ?�- I 4i Pplegt "Y'vi-player , 301_- 574' 39 .. 565 47. 574 'f m- f art ipa Pale I LOCATION MAP F tvirr,w hicro,t5 F « iretty PureJ Rd F ak at )> Pry it Co S It f Nr; ca TsJn pkr , Ave v m Rutks>je Or 2 `g For, 3 0 3 �rr�e, �d •t �. 99 ai tx V �0 K 35A puff RAI .,,Kathleen 582 { �a, Git)Simr3a 5} LA* L go `SWrn 563 51.3 Medula t R4,....,..7 -c ►meter ."wr SITE rt� 41 CakpTict AUlie 54 Ms�r�y OfIr eath Zo ti gtlt�fr�tss "La' Rd , a� NUc Awee` +: t Y 121f, Avr, t q PeA u, "� f 1 It l Fir1e, _ t+i W P, � UETSLKAL TelMES: 1. Below is a list of supplier of the project utilities: Water & Sewer: Fire: Telephone: City of Zephyrhills Utilities Zephyrhills Fire Department Verizon Engineering 5335 8th. Street 6907 Dairy Road. 10402 North 56th Street Zephyrhills, Florida 33542 Zephyrhills, Florida 33542 Temple Terrace, Florida 33617 (813)780-0015 (813)780-0041 (813)989-7968 Ron Mixon Electrical: Cable: Progress Energy Private Solid Waste: City of Zephyrhills Sanitation Department 39421 South Avenue Zephyrhills, Florida 34542 (813)780-0022 2. The present zoning on the area of the preliminary plan is R-4 High Density Residential District. 3. Fire protection will be provided by onsite hydrants. Zephyrhills Fire Department Station 1. 4. All Utilities will be underground. 5. If during construction activities, any evidence of historic resources including, but not limited to, aboriginal or historic pottery, prehistoric stone tools, bone or shell tools, historic trash pits, or historic building foundations are discovered, work shall come to an immediate stop, and Pasco County and the State Historic Preservation Officer shall be notified within two working days. 6. Project Team: Survey: Property Owner Developer: Geotechnical Consultant: Simmons and Beall, Inc. King Investments, LLC. The Richman Group of Florida, Inc. Faulkner Engineering Service, Inc. P. O. Box 1297 3340 Crenshaw Lake Rd. 580 Village Boulevard, Suite 360 12904 Dupont Circle 12218 Hwy 301 South Lutz, Florida 33548-4752 West Plam Beach, Florida 33409 Tampa, FL 34626 Date City, FL 33526 Ph: (813) 963-7139 Ph: (561) 242-4814 Phone: (813) 818-8307 Construction Consultant: Contractor: Architecture: ConsTech Consultants, Inc. First Florida Forum Archittecture & Interior Design, Inc. 748 Navarre Avenue 1533 Sunset Drive Suite 150 745 Onenta Avenue Coral Gables, Florida 33134 Miami, Florida 33143 Altamonte Springs, FL 32701 Ph: (305) 461-0399 Ph: (305) 665-1146 Phone: (407) 830-1400 7. No known historic resources identified by the Pasco County Comprehensive Plan. 8. No Areas of Potentially Significant Habitat are shown on Map 3-1 of the Pasco County Comprehensive Plan. Phase 1 -Construction Plans ]Fort for King Section 3 Township 26 South Range 21 Ea,1114not Pasco County, Florida JUBMIT-fEV PLANT SKA E BEEN WBIs "%Y ZEPHYRHILL A� CE �,� Date: / Please be advised KingInvestments,. this review of plans submitted Is �; cursory review to assist the contractor in compliance with applicable fire safety codes. This review is not intended to be a final approval of the submitted plans. It is the contractor's sole responsibility to ensure that the plans are in complete compliance with all applicable NFPA codes and local ordinances. In the event that further examination or site inspection reveals areas of non-compliance, it shall be the contractor's sole responsibility, at their sole expense to bring those areas in compliance. The City assumes no responsibility for the contractor's failure to be in compliance with aU applicable NFPA Codes and local ordinances. Prepared for: Owner: 3340 Crenshaw Lake Rd. Lutz, Florida 33548-4752 Ph: (813) 963-7139 Developer: The Richman Group of Florida, 580 Village Boulevard, Suite 360 Site Data Phase 1 Description Acreage +/- Stormwater Pond 3.77 Apartment Buildings 1.14 Clubhouse 0.10 Garage 0.02 Compactor 0.04 Mail Kiosk 0.01 Picnic Pavilion 0.02 Pavement 2.32 Sidewalk 0.44 Curb 0.05 Air Conditioning Unit Pad 0.03 Pool 0.15 Pumping Station with Driveway 0.03 Open Space 5.11 Phase 1 Area = 13.23 Phase 2 Description Acreage +/- Wetland Conservation Area 0.85 Stormwater Pond 0.92 Apartment Buildings 0.96 Compactor 0.02 Pavement 1.89 Sidewalk 0.23 Curb 0.03 Air Conditioning Unit Pad 0.03 Wetland Buffer 0.37 Open Space 7.75 Phase 2 Area = 13.05 Total Site Area = 26.38 Acres vvest raim tseacn, rioriaa jj4uy Ph: (561) 242-9461 NOY. �nlCJ LaNi-, �561) 242-481-14�, i1\o 38G,�(� llaf�e:� paKsCr ��M� 9r1 34350- valle1 oak>cr- ��{Ppared by: y S fl 11 80 PCONSULTING Planners Engineers 18115 U.S. Hwy. 41 N., Suite 6 0 Lutz, FL 33549 Tampa Ph. (813) 949-7449 Fax 948-1712 www.sprinkleconsulting.com Property & Project Boundaries P -oject Boundary = Phase 1 = 13.23 Acres a `4; , I Phase 2 1 Project Boundary = Phase 1 + Phase ? = 26.38 Acres Inc. Land Use Analysk Total Apartment dwelling units = 240 DU Gross Density = 240 dwelling units + 26.38 Acres = 9.10 DU/Ac Maximum Building Height 35 Feet Maximum Percent Impervicus 30 Apartment Unit Mix in Phase 1 = 24 -1 B/1 B; 64 •- 2B/2B; 32 - 3B/2B Apartment Unit Mix in Phase 2 = 72- 1 B/1 B; 32 - 213/213; 16 - 3B/2B Parking Analysis Spaces Parking Required = 2 Spaces per dwelling unit = 2 x 240 = 480 Parking Provided Phase 1 = 248 Phase 2 = 242 Total = 490 Handicap accessible parking spaces Required = 9 Handicap accessible parking spaces Provided in Phase 1 = 11 Handicap accessible parking spaces Provided in Phase 2 = 10 Total = 21 Building Data Name First Floc r Area (sq.ft.) Gross Floor Area (sq.ft) Number of Floors Type 3 10,426 29,173 3 Type 3-A 10,426 29,173 3 7,795 22,343 Type 18 3 11,693 Type 24 33,515 3 Clubhouse 3,378 - - 1 - Picnic Pavilion 830 Garage, Porch 1,006 _ & AC -Pad - - Compactor 909 - - NOTE: Proposed development complies with the Comprehensive Plan. LEGAL DESCRIPTION: Tracts 15, 18 and 31 and all that part of tracts 14, 19 and 30 lying East of the S.A.L. right-of-way, per Plat of the Zephyrhills Colony Company lands recorded in Plat Book 2, Page 6 of the Public Records of Pasco County, said lands being in Section 3, Township 26 South, Range 21 East; and Commence at the Northwest corner of tract 2, in Section 3, Township 26 South, Range 21 East, Zephyrhills Colony Company lands, according to map or Plat thereof Recorded in Plat Book 2, Page 6, Public Records of Pasco County, Florida, and run thence South, 10 feet; thence East 10 feet for a point of Beginning; thence run East, 120 feet; thence South, 305.6 feet more or less, to the South boundary of said tract 2; thence West, 120 feet; thence North, 305.6 feet more or less to the Point of Beginning; and a strip of land 150 feet in width, i.e. being 100 feet wide on the East side and 50 feet wide on the West side of the center line of the roadbed of Grantor's former main track right-of-way; said strip of land to begin at the South line of Northwest. 1/4 of the Northeast. 1/4, Section 3, Township 26 South, Range 21 East and extend North Westwardly 1096 feet as measured along said centerline and constituting the Eastern most 150 feet of Grantors 200 feet right-of-way, which right-of-way is 100 feet wide on each side of said center line; said strip of land being bounded on the North and south by the respective property lines of Grantees, if extended; and that portion of that certain former 30 foot road right-of-way lying East of tracts 14, 19 and 30 and west of tracts 15, 18 and 31 as shown on the Zephyrhills Colony Company lands subdivision of Section 3, Township 26 South, Range 21 East as Recorded in Plat Book 2, Page 6 of the Public Records of Pasco County, Florida. and parcel "a": the East 15.00 feet of the West 145.00 feet of tract 2, Zephyrhills Colony Company lands subdivision of Section 3, Township 26 South, Range 21 East as Recorded in Plat Book 2, Page 6 of the Public Records of Pasco County, Florida. less and except the North 10.00 feet thereof for road right-of-way. and less and except; being a portion of the vacated railroad right-of-way as recorded in O.R. Book 687, Page 74, of the Public Records of Pasco County, Florida, lying within the Nnorthwest 1/4 of the Northeast 1/4 of Section 3, Township 26 South, Range 21 East, and being further described as follows: Commence at a p.k. nail and disk found at thenorth 1/4 corner f Section ; th n N 2" 4 rt co e o3 thence 89°58 0 E 16.07 feet along the North line of said section 3 to a p.k. nail and disk (Is5720) set on the centerline of survey for Fort King Highway (C.R. 41) (South); thence S 25'26'12" E, 365.60 feet along said centerline of survey to a point; thence N 89°37'32" E, 27.60 feet to a point at the Northwest property corner, being the Point of Beginning; thence N 89-37-32" E, 110.30 feet along the Northerly property line to a 3 inch by3in h concrete monument found on the proposed Easterlyri right - way line for Fort king Highway (C.R. 41); thence S 19°55'54" E, 51.22 feet along said proposed Easterly right-of-way line to an angle point; thence S 25°26'12" E, 245.00 feet along said proposed Easterly right-of-way line to an angle point; thence S 64°33'48" W, 95.00 feet along said proposed Easterly right-of-way line to a point; thence N 25'26'12" W, 342.71 feet along the Westerly property line to the Point of Beginning. Zoning, Future Land Use & Existing land Use DAUGHTERY ROAD ---� ---- North R-4 RES-6 I 26.38 AC. VACANT I X'G)� 1 Index of Plans # Name Revisons Date 1 Cover Sheet 12 09/30/10 2 Site Plan 6 09/28/10 3 Truck Wheel Tracking Plan 1 07/15/10 4 Overall Grading Plan 5 09/28/10 5 Phase 1 - Grading Plan 6 09/28/10 6 Phase 1 - Paving and Drainage Plan 5 09/30/10 7 Phase 1- Roof Drainage Collection System 1 07/15/10 8 Construction Stormwater Management Plan 5 98/24/10 9 Water Distribution and Fire Protection Plan 6 08/31/10 10 Sewage Collection and Transmission Plan 7 09/30/10 10A Phase 1 - Underground Utility Conflict Plan 2 09/30/10 10B Phase 1 - Underground Utility Conflict Details 1 07/15/10 11 Pumping Station Site Plan 4 08/31/10 12 Pumping Station Details 2 07/15/10 13 Fort King Road and Daughtery Road Improvements Plan 5 09/30/10 13A Fort King Road - Phase 2 Improvements Plan 1 09/30/10 14 Fort King Road Improvements Sections 5 09/30/10 15 Daughtery Road Improvements Sections 4 08/31/10 16 Notes and Testing Schedule 3 08/31/10 17 Pond Sections 4 08/31/10 18 Site and Drainage Details 3 07/15/10 19 Site and Drainage Details 2 _ 07/15/10- 20 Utility Details 3 09/30/10 21 Utility Details 2 07/15/10 22 Phase 1 - Traffic Signage and Marking Plan 3 08/31/10 23 Offsite Traffic Signage and Marking Plan 6 08/31/10 24 Offsite Sight Distances Plan 6 08/31/10 Stormwater Management System designed by: Bruce H. McArthur P.E No. 41119 These plans have been prepared in accordance with the current version `.•``•�� ''fit of the Manual of Uniform minimum +'* t��Ir °s, standards for design, Construction .° 0 and Maintenance for Streets and ' Highways, State of Florida and are Ivil Engineer y in compliance with the standards, Yi : Carlos A. Vasquez" therein except as noted on the �' P.E. No. 20.684 ` plans. Any deviations noted on the,��, q plans substantially comply with the `'. Novembite A1) 810 intent of the standards. `sg,® I *•` 1111D• SCI PROJECT NO. 1372-10 -i- I 1 11 W1 cp r- M M (L CY) C*4 E 0 z 3: '9 r n. to (L Ad a- C-4 r- c zq 40 3� t-anang U1 IV LXI1 IV %jI IV L.01 10 raring QIUOWCIIR 04C4 20/( 02 Type "13" Curb Notes: 20" Elevations & contours shown are 6- \2 6 referenced to NGVD 29 datum. i it 030" BENCHMARK 22" TOP OF IRON ROD CAP #3555 37 ELEVATION 87.59 16" 261) ij lic� 28"0 \'N COO•N' ka i� V, i 011h N &J A ope k, 47 71'of W"swala 0.5% slope % slope \ \ 151'of 'V" swalle @ 0.5 90'of %1 swale @ C6% sl 'Ok ANNEL-A 12" 230'of 'V" swalle @ 0.5% slope 057 NN' 'N - - - - - - - - - - RA 'k 0"6'\ -4 16 10" kkk 16i P 83 al 9 N, 7 1 Z- ro "N AB- 8 82.17'@1.0% 174.67'@l. % 191.39'@1.47% VA \ N' ' NN 1!nw: - - - 19 NN W ABI -- 421 1. 6\' 41 ♦ \ .\ \ a5t� \ i } \ \ i 1 / T s��� �p� 0 &\6 9 (8j, 9�' fy SHW 78.00 0- BI SHW =76 'N' /C 5 -NN NN N, It -----r 9 . 4j i FF EL.=D�J 0 87 % 4 NN`NN,' 050 71- FF EL.= 88.84 N. % % v 7" 12" LP 11 V B-18 B-1 9 CtN 0 B-20 1 1 2, A 'POND, C V N, FF EL.= 89.8 FF El-!= 89.9 87. NN 7C N, \\\\,\ \ \ 9 V"l NN �5.95 9 V %. , N 2 0 , \ , \\ \r- . . - NN' % 1/0)) 17)) N\ "N' PB-4 N, NN (0 B-17 A .61 0 \ \ ", VO SHW 80.25 602% ♦ \'9 Yet t2" TW B-3 03 •`'1 l,-�/ !r! � \� �; � � \� ` Bg J • \ /`2` j 1 �� .r/ 190 A % \ \ 0 89.63 "N`-\ v" A 8" 10" \J\ ♦ \8().389.90 5 $7 7 1) A O)y 1621 44" N POND B /PB-2 1Z \ \ \ , DHW25= 85.24 S, 1 2!� DHWioo_ 85.77 PB-5 B-4 TOP = 88.00 BOT = 84.00 SHW 83.50 FIRE HYDRA?0. i4 - 9.63 f2" B-13 04/11 % % LP' + 89.93 k :Ipp It 020 NN EDGE OF' WATEW OW 05-z02-'05 ♦ \0 1 f ELEVA'TION -74.91t B-5 0 R49- \'N' 0 32" B o B-6 *4� BENCHMARK 14 . . . . . . . . . . . . METLAND A CUT SET SQUARE NE CORNER OF Lit 9.93 0'8525,Kcret LIFT STATION ND ELEVATION 89.69 86. 21' . ...... . . . ..... ..... 9" ♦ \ \•. � �\ � $ °moo ;' / I ' 1 ' ' \ ! \ \ . d ,. ,. ., d , . a . '� k 9 - - - - - - - - - - - - 19" 9.10 9i 66" 0 5P N,X\ 1\ ... . . . . . . 89 '59 12" 16" 12"' % • 16�616" B-7 9"41 tiP040 2 5', 8 A0 24" 7W I N 89.93 L 25" 8 . . . .......... . .. .......... • 8.9 'N 1 6 7 7 N, 016" * 18" -1V 24" 14' 6 N % ak i i �* 351P NN-64 6 % 0"-'% , l.. n 4 %L 'N 00 4b6 0 636"\ I "N 5t' "x N, NN j 7 NT7 bl- "N 9" TWIN 'k W1 6" 26" 14 0\24 B-�12 Legend• 0 3�" Q 8" TWI X- Direction of Flow IN 0 23)* NN Z' B-7 Soil Boring % . . .... N, N ON�2" N, N1\ DHW Design High Water 030 0\2 *18 TWIN IN FFE Finish Floor Elevation sojka NN //' -- 10" TYPICAL AISLE (N.T.S.) 1\1 til- 4 2 6 161 22" 3 6," 24" 25 N' 5f 0 N 27 db A 0 6 Update per SWFWMD comments. 09/28/10 5 Added offsite ditch. 08/31/10 4 Update per new site plan. 07/15/10 3 Regradle phased plan. 06122/10 2 Update per SWFWMD comments. 09/24/08 1 Per city comments. 05/08108 No. Revisions i Date I CU >I Ito 0 C: C: LL O ICU C CU L) C) 0 ILL if 'q C) 0 U) U) CU 0 ca ICU 0 Cl) CU N LL L6 anos, :W84 ve ate hovQ0bW- Drawn: Yzy Checked: Scale: 1 11=50' Dwg: 1372-10 Grading Plan Job No: 72-10 Sheet Of 27 5 Sheets Type G DBI __ #13 FDOT Index #233 Top EL.= 87.63 INV (S)EL.= 84.62 3 titer ---- ��, 79.00 000 / Y ��• / / Y a ♦ Y � m 5e001 Qr�� e�' i 'YYY♦Y� �Qray J i�YY�Y♦r / YY♦Yw iti�/Y Y v a. Y a Y . ♦ < .' .f a Y Y a a, Y ,,, �♦ a♦ Y♦, a , a Y Y y Y ♦ Y .. ♦ Y . Y Y Y ♦ Y / /` Y♦♦♦♦ Y Y Y♦ Y a Y♦ Y♦ Y Y a Y Y♦ Y Y. Y Y♦. .. k♦ a a Y Y a V♦ a♦ Y a a a ,Y Y♦ Y Y Y a /♦ Y ♦ Y a V Y Y W Y ♦ Y Y Y ♦ Y♦ a Y♦ Y Y Y Y Y Y a ♦ Y Y♦ Y Y Y Y Y Y Y Y♦ a Y� iY ♦ Y ♦ Y Y Y Y .r Y Y Y Y Y Y Y a X I w a Y ♦ Y Y . ♦ � . Y Y Y Y Y Y a ♦ a I+ Y Y♦ Y♦ +; y♦♦ Y Y Y Y a. Y �\ Y YW Y Y Y Y Y . a. .♦ ♦ fTLA . a♦ a Y � Y X\ •p' Y i ♦ ♦ Y w Y ♦ ♦ ♦ ♦ a• Y Y \ � Y a a Y a Y Y Y Y .. ♦ Y Y a Y a a Y a♦ Y Y♦ Y W Y♦ Y a. � Y \ \•�.Y Y Y Y Y♦ Y♦ Y Y Y a Y a♦ Y Y Y Y Y Y Y W Y Y a♦ \ ♦ Y Y ♦ ♦ Y Y Y Y ♦ ♦ ♦ W L ` t �. ♦ i 'Y W .Y V Y Y r ♦ W \Y k� NOTES: 1) Speed bumps to be placed at Owner's direction during paving activities. 2) Bidding contractors to add a $5,000.00 allowance for the speed bumps. Base Header Curb Note: Materials and method of construction same as for Type"D" curb. ED 05 ZD 8" 2'-0" `Note: (1) When used on the high side of highways, the cross slope of the gutter shall match the cross slope of the adjacent pavement and the thickness of the lip shall be 6", unless otherwise shown on plans. Type "F" Curb Asphalt Path Section �._...._ _ , �• Asphaltic concrete (Type S-3) Subgrade = 12" of Type B Stabilization with compacted subgrade to 98% MP (LBR 40) I inht rlrity Dwomnn+ Cor+inn c.......,,....i �,.,,..... _ , 5. Asphaltic concrete (Type S-3) Base = 6" of crushed concrete Subgrade = 12" of Type B Stabilization with compacted subgrade to 98% MP (LBR 40) 1.5 x 0.44 = 0.66 6 x 0.18 = 1.08 Structural Number = 2.70 Heavy Duty Pavement Section — c...,,...,...i �,......,. _ �• Asphaltic concrete (Type S-3) T «A Base = 8" of crushed concrete Subgrade = 12" of Type B Stabilization with compacted subgrade to 98% MP (LBR 40) 1.5 x 0.44 = 0.66 8 x 0.18 = 1.44 12x0.08=0.96 Structural Number= 3.06 Property Line Proposed Storm Pipe Heavy Duty Pavement Light Duty Pavement 5 Added offsite storm pipe. 09/30/10 4 Added offsite DBIs. 08/31/10 3 Update per new Site Plan. 07/15/10 2 Update per SWFWMD comments. 09/24/08 1 Per City comments. 05/08/08 No. I Revisions Date M L 00 M M N 1� C O O CU LL tL N Yy 0� t � � Q C:)X O to f0 r— ILL O O N O U . i✓ 0) CID co Z Z 9 C) ,C Iq CM — J LLJ S o CD CO t i C 0 + 2 N m I` Z n aa C 1J O o u c LO CU 'D E o Iy � CC) CUm ICU C: `v I U) O C ` 0) CU o }' O o o �L2 (')= () C) L O 0) CU M C O . _ U vi '> s M ^, Cl) CL ' O CU 0 U. �_ O` V) CU IZ- U �� •�� 'Civil Eng 'Civil" arlos A. Vasquez 20684a / � �Z November0 Date Drawn: YZY Checked: Scale: 111=60' Dwg : Paving and Drainage Plan Job No: 1372-10 Sheet Of 27 6 Sheets �� �w��wwww� � ■wnu �iy�rr a�� -- 11 I II I --- -I - I I I I I S i1 o LTJ14 D 16" 12„ GGQ 57., 10„ '�� 1517 6 „ „ s1 \� Dumpster 42» 17„ "12 " %% \\ l F e\ ` 32" �: came \ L/f \ \ 14 7"W 12» rPond 5,> 6» 6„ 8„ 811 o \\ 14 12' Pool 8Y, 9„ 141) t. 12 \ \\\ �119" � TWI 0 o O � 12" A » �10 "r Q Q 0 60" %` \ \\ 12" TW Ica 17 \ Pond 1 8„ 9„ 10» 8„ �\ \ 5 7 10 16 0 44" 12 0) Pond ® 19„ � ;�•� y % \ \ \ 12" 1 1 \ \ 8 ' 693LFof2"drow ofSilt Fence ,- Wyyy_•.WvyW / n V �.� \ \ \ 1932" I WWW.y.`.'.`w`WW�yyyi+W-Wy ` \ \ \,\ \ 1 1 �� •48" y _ y y . . .wsr`L ID . W y _ WWWWW_W.W.W.WW_WW_W_W=� N `\\ \ 19" \ 9" 66)) WWWWWWWWWWWWWWW_WWW_WWW 1 12" � 16" •12" ®50 y +� 66" r 40 g„ 25" ® 8„ 24" TWIN 8 . 1 1�25pp > %� \ \ \ 16 19 2 •24 � �y } \\ \ ® 8 14 6 6 » 1 m \ \ \\ II 35 1 1 ! 46 34 i \ \ \ O 13" \— 3-2 0 l \ 30' 00 13" *36" 1 \ „ Lf N \ \ / 7» 1 1 » +Ii 54► 48" » \ \ 8Al 24» 1 26" 1 ♦ % \ \ 9„ TWIN 16)t 9" 24" \ \\ �\ 10 10" 33" \ \ `t 8" TVL'IP1 023" z° \ \ 8" TWIN 1 042" 1 027„ *300 18" 1" 8TWIN 1 o `1j\. \ \ \ 030" 1 \ 0 26" \� \ \\ \� • 1 22" 36" 24" 1 \ % a \ \ \ 0528" 30" 1 1 0 4226"� �27" 27" 32 20 27„ 1 `\ \ 027 \ � %22»� 21 i " 22°} 16» 17" I ti \0-, \18 28" 24" & ® 45" 33„ i36" 013",r O \ '� 36» \\ \ ti 8,> 17» 20„ 32"0 •38" 60"30" 25 �►t``' € %32 1311 0 18" 30» ° \ \ 20 » 02p y 21 " 1142 032 ®i91 �\ `', 7 015„ „ » \ \ \ �® 12$' 8" 21 » 48 21 ► » .� t \ �., ` „ 1136' 30" V 24" 25 TWIN 0 Frank Ripa t , \\ \\ 26 1 1 12 „ 18"* 021 „ Member �\ \ 12 +r18 24 \, 14 24 i 30 18 King Investments, LLC. \ \ \ \ 36's \ Ill 5" 7" 24" TWIN ®30" 34"0 17" 0 1409 Tech Boulevard, Suite 1 ` \\ 20" 7 23" 7" �► 36" TWIN 16 TWIN 24"* T Tampa, Florida 33619 17 34 " 34 » "% 1 Telephone: 813) 917-9518 ��\ \`\\ \ 7 52" 0 40" 20" 24'36 18 28' *24� s 30� 0 \ \ \ .,�'..o..r..wi.r�i..,.rrew.,.x..or,ew,r,r N The owner/agent is aware of and must assure 13" 20" 20 20'20'�18 7" 2g" 17 TWIN 19" TWIN 18" M maintenance of the erosion protection that is �% ` \\ \�% associated with the project during construction 3 v Optional Post Positions Filter Fabric (in Conformance With Sec. 985 FDOT Spec.) Principle Post Position (Canted 200 Toward Flow) Filter Fabric low Operation & Maintenance Instructions for Construction Surface Water Management System 1. Contractor is responsible for managing and implementing this Construction Surface Water Management Plan and Stormwater Management System. 2. The installation of temporary erosion control barriers shall be coordinated with the construction of the permanent erosion control features to the extent necessary to assure economical, effective and continuous control of erosion and water pollution throughout the life of the construction phase. 3. The type of erosion control barriers used shall be governed by the nature of the construction operation and soil type that will be exposed. Silty and clayey material usually require solid sediment barriers to prevent turbid water discharge, while sandy material may need only silt screens or hay bales to prevent erosion. Floating turbidity curtains shall be used in open water situations. Diversion ditches or swales may be required to prevent turbid stormwater runoff from being discharged to wetlands or other water bodies. It may be necessary to employ a combination of barriers, ditches and other erosion / turbidity control measures if conditions warrant. 4. Where pumps are to be used to remove turbid waters from construction areas, the water shall be treated prior to discharge. Treatment methods include and are not limited to, turbid water being pumped into grassed swales or appropriate vegetated areas, sediment basins, or confined by an appropriate enclosure such as turbidity barriers, and kept confined until its turbidity level meets state water quality standards. 5. The contractor shall schedule his operations such that the area of unprotected erodible earth exposed at any one time is not larger than the minimum area necessary for efficient construction operations, and the duration of exposed, uncompleted construction to the elements shall be as short as practicable. Clearing and grubbing shall be so scheduled and performed that grading operations can follow immediately thereafter, and grading operations shall be scheduled and performed that permanent erosion control features can follow immediately thereafter if conditions on the project permit. 6. The contractor and/or owner's representative shall provide routine maintenance of permanent and temporary erosion control features until the project is complete and all bared soils are stabilized. 7. Silt fence shall be located at the perimeter of construction limits, locations as shown hereon and at locations as defined by field conditions. 8. Inlet structures, pipes and stormwater basins shall be inspected for siltation accumulation every six months (minimum). Accumulated silt (greater than 3 inches) shall be removed. 9. Pond slopes to be sodded immediately upon establishment of finished pond stages. 10. All silt fences to be installed per the included details prior to any on -site clearing. 11. Where finished grade exceeds 4: 1, sod shall be fastened with wooden pegs spaced 3 feet apart and driven flush with the surface of the sod. 12. Protection around inlets shall be provided in accordance with FDOT Index #102. 13. Hay bales shall be used to protect fill slopes in accordance with FDOT Index #102. 14. All demolition debris shall be removed from site and legally disposed of. v v — — — — — 15. The soil erosion and sediment control devises shall be installed prior to construction, maintained throughout construction and until site is permanently stabilized. 16. All sodded slopes over 4 to 1, shall be installed with sod pegs. 17. Any off site disturbance shall be restored to the pre or better condition. D 1 Ditch Ditch NIIIIIIIIIIJIIIIIII IBIII JIIIIhIIJI� Anchor Bales With 2 - 2" x 2" x 4' Stakes Per Bale. DITCH BOTTOM INLET HAY BALE PROTECTION AROUND INLETS n .* Sin Fence Protecton Around Ditch Bottom Inlets SILT FENCE APPLICATIONS 5 Update per SWFWM comments. 09/24/10 4 Added notes 15 through 17. 08/20/10 3 Update per new site plan. 07/15/10 2 Update per SWFWMD comments. 09/24/08 1 Per City comments. 05/08/08 No. Revisions I Date rn ch Go 3 M tt c0 p a c 0 O N N o 3 � Q o o x c0 U- 0 cc a� rn E �. U � 8 r m E-, z 4)rn v r= 'i6 W 'T M 2 � ai rn w er=z La ui a c `O c : WCo n o u LO �' a ca C002 a 0 FM- m CU C O N LZ E O c cU O o CU 0 v v L V CD L 0) C CU CU O �C U D E L O fn s CL N O O O U J U c O U il��n!R3,. JB • •., -"` � wry ivfi, Enoe&r - rioi�,tA/qui@ - - 2(�.84 Novernb� ;kiq� Drawn: YZY Checked: Scale: 1 "=60' Dwg: 4MPs Job No: 1372-10 Sheet Of 27 8 Sheets I I I I I r I I 1 11 1_ 1111111. o+ c 0 } c 0 } } m 2 a di 0 0 0 a l u a E O 0 Z T 0 �i L 7 FS 0 O J a rn v c 0 a L m 3 0 N 13 C O L 3 0 IL rn a 0 1 N r M O_ I N n M 3 IL- I rn c 0 c 0 } m 2 d M M d O O O N E i 0 z 0 v a� L 7 FS 0 J a rn a v c 0 a 0 cn v c 0 m 0 3 0 a. rn a 0 i N n M O_ I N n M 3 I I ° I I i I I I I II 1 I IA F -- �. • ^.,, I I 1 -I- -. _ __- _ I. I I I I I 1 iiiiiiiiiiiiiiiiii y amen xlmuru Imina ��a+af�AJJI "UL6 aL, , 41"; d.. -UA l 1111[11LUM ��II�IY181■� ItI rn c } } r m a N O 0 0 N m a E ` 0 0 z 0 v FE 0 0 o_ v rd U i~ 0 0 a� m D c 0 0 c 0 4 0 a 0 N n r� 0 N n M 3 v au.0 89.0 88.0 87.0 86.0 85.0 84.0 83.0 82.0 81.0 80 0 Proposed Grade Existin 3 Grade 7-7 --- 8 Fire Main 4 Water Main _1b /514 18" ADS 83, Mf . / /-Proposed Grade Existin j Grade 8' F re Main 4 Water Main 18" ADS 84.33 / au.0 UU.0 aU.0 /-Pmposed Grade 89.0 E)dsbnl 3 Grade 89.0 ,-Pm posed Grade 89.0 Existi Grade 88.0 88.0 - - _ 88.0 jE 87.0 87.0 87.0 8" F re Mail 4 Water Main 86.0 86.0 86.0 85.0 85.0 85.0 84.0 84.0 84.0 83.0 83•0 8" Sanitary Sewer, 2"Min. 83.0 82.0 82.0 82.0 81.0 81.0 81.0 18" ADS Ann 180.44 Ann An n Pro posed Grade Existin 3 Grade - - 8" F re Main 4 Water Main /Z \xv8*kin. 18" ADS 83.60 Detail #1 Detail #2 Detail #3 Detail #4 Detail #5 Horizontal: 1 "=30' Horizontal: 1 "=30' Horizontal: 1'=30' Horizontal: 1 "=30' Horizontal: 1 "=30' Vertical: 1 "=3' Vertical: 1'=3' Vertical: 1 "=3' Vertical: 1 "=3' Vertical: 1 "=3' 90.0 ro re 8 Existin Grade 89.0 88.0 87.0 88.0 85.0 84.0 83.0 82.0 81.0 80 0 Proposed G de �Existin Grade 2 8" Fire Main 4" Water Main 8" Sanitary Sewer 81.55 Proposed Grade Existin j Grade c i ire aln Water Main c 74 90.0 89.0 89.0 88.0 Proposed Grade Existin Grade 88.0 87.0 _ - - 87.0 86.0 86.0 85.0 18" ADS 85.0 84.0 84.0 83.0 83. 83.0 82.0 8' Sanitary Sewei 82.0 81.0 24 ADS 81.0 80.0 An n 7n n 90.0 89.0 Proposed Grade7stin g Grade 88.0 c 87.0 8" F re Main 4 Water Main 86.0 85.0 84.0- 83.0- 82.0 81.0 8" Sanita 80.0 Sewer 79.73 790 Detail #6 Detail #7 Detail #8 Detail #9 Detail #10 Horizontal: 1'=30' Horizontal: 1 "=30' Horizontal: 1 "=30' Horizontal: 1 "=30' Horizontal: 1 "=30' Vertical: 1 "=3' Vertical: 1 "=3' Vertical: 1 "=3' Vertical: 1 "=3' Vertical: 1 "=3' 90.0 90.0 89.0 89.0 - - _ _ �Existin 90.0 89.0 0 ProG de Grade 88 0 Proposed ling Grade 89.0 88.0 - - - _ 87.0 87.0 Proposed G de 88.0 87.0 86.0 86.0 87.0 86.0 � 0 85.0 Existi Grade c 4 Water Main 86.0 i 85.0 84.0 84.0 8" Fire Main 8" Fire Main Water Main 85.0 741 84.0 ADS 83.0 83.0 83.67 84•0 83.0 82.0 82.0 18" 83.84 83.0 8'M n' 82.0 81.0 81.0 8' Sanitary Sewer 82.0 81.0 8' Sanitary r 80.0 80.0 81.0 80.0 79.0 79.0 an n 790 7A n 7a n Proposed GradeJ Existin Grade 8" ire Main 8" Sanitary Sewer "U.0 89.0 Proposed Gi adia] Existi _ Grade 88.0 87.0- 86.0 85.0 4" Wate r Main 84.0 83.0 82.0 81.0 80.0 8" Sanitary Sewer 79.0 78 0 --- Detail #11 Detail #12 Detail #13 Detail #14 Detail #15 Horizontal: 1"=30' Horizontal: 1'30' Honzon�ta:I 30' Horizontal--. -30' Honzonnta :I 30' Vertical: 1 "=3' Vertical: 1 "=3' Vertical: 1 "=3' Vertical: 1 "=3' Vertical: 1 "=3' 90.0 90.0 89.0 88.0 87.0 86.0 85.0 84.0 83.0 82.0 81.0 80.0 79.0 7a n Pposed Grade EAstin 3 Grade 18" ADS 83,46 8" Sanitary Sewe Proposed Grade Existin 3 Grade c 8" Fire Main 4 Water Main 18' ADS -U3.-4T- "N in. / 89.0 Existing G e-/ I -Proposed Grade 88.0 87.0 90.0 86'0 89.0 4" Wate r Main 85.0 88•0 84.0 87.0 83.0 86.0 82.0 85.0 81.0 84.0 80.0 83.0 8' E anitary Saws 79.0 82.0 78.0 81.0 77n Ann Proposed Grade Existin Grade Fire Main 4 Water Main A�j -Nor- �E'dsfing Grade 89.0 Proposed G e 88.0 87.0 86.0 85.0 18" ADS 84.0 83.0 8" S 3nitary Sewer 12'Min. 82.0 81.0 80 0 Detail #16 Detail #17 Detail #18 Detail #19 Detail #20 Horizontal: I" 30' Horizontal: 1`=30' Horizo�30' Horizontal: 1"=30' Horizontal: 1 =30' Vertical: 1 "=3' Vertical: 1 "=3' Vertical: 1 "=3' Vertical: 1 "=3' Vertical: 1'=3' 1 Updated per new Site Plan. 07/15/10 No. Revisions Date CO cM CM O � C O LL I, N O � ob � O � CO K Q O O 0) n48 0 cD E COu C Z I Cm U tldtitltlfltltl� F W 01 C rV co Q _c U) CO CU i1 C "� V C O a O _ � U o 0 U C.)o C "L Cu -- U0 N o Wv A' Q C15 s a V/ N �W U a. 0 U U) Cu d' m ii 'I Eiikoieerry arbsWsque7.•'� 84 November 11, 2010 Date Drawn: YZY Checked: Scale: As Noted Dwg: Underground Utility Conflict Job No: 1372-10 Sheet 10B Of 27 Sheets I li ' t j 11 mr� ..._ I "w r. NORTH cal r �I 0 rE 6 0 o_ rn 3 m 2 c 0 U r c 2 v+ 0 a a a 0 N n 0 3 v UU.0 89.0 88.0 87.0 86.0 85.0 84.0 83.0 82.0 81.0 80 0 proposed Grade Fyristin 3 Grade C 8 Fire Main 4 Water Main jai �C• / 18" ADS 83.30 Mi ./0/ Proposed Grade Existin 3 Grade -7 8" F re Main 4 Water Main EaD 18" ADS 84. "N in. / / UU.0 vv.0 Proposed Grade 89.0 E)dstin 3 Grade 89.0 88.0 88.0 C 87.0 87.0 8" F re Main 4 Water Main 86.0 86.0 85.0 85.0 84.0 84.0 83.0 83.0 82.0 82.0 81.01 1 1 81.0 18" ADS nn n W.44 An In /-Proposed Grade Existin Grade 8" Sanitary Sewer 83.56 2"Min. Pro posed Grade Existin 3 Grade 8" F re Main 4 Water Main lb 8" 18" ADS 83.60 in. Detail #1 Detail #2 Detail #3 Detail #4 Detail #5 Horizontal: 1 "=3V Horizontal: 1 "=30' Horizontal: 1 "=30' Horizontal: 1 "=30' Horizontal: 1 "=30' Vertical: 1'=3' Vertical: 1 "=3' Vertical: 1 "=3' Vertical: 1 "=3' Vertical: 1 "=3' au.0 89.0 88.0 87.0 86.0 85.0 84.0 83.0 82.0 81.0 80 0 Proposed Gi de '�-Existin g Grade i 8" Fire Main 4" Water Main 8" Sanita Sewer 81.55 Proposed Grade Existin j Grade i ire a n a r Main .b 83.74 90.0 P re e EAstin Grada au.0 - oa.0 89.0 88.0 ProposedGrade EAstin j Grade 88.0 _ _ _ 87.0 87.0 86.0 - 86.0 85.0 18" ADS 85.0 84.0 84•0 83.0 83.83 83.0 82.0 8" S enitary Sewei 82.0 81.0 24" ADS 81.0 1 80.0 an In 7a In 90.0 89.0 P_ roposed Grade _ �E Wn Grade 88.0- c ZD 87.0 8" F re Main 4 Water Main 86.0 85.0 84.0 83.0- 82.0- 81.0 8" Sanitary 80.0 79.73 7A n Detail #6 Detail #7 Detail #8 Detail #9 Detail #10 Horizontal: 1 "=30' Horizontal: 1 "=30' Horizontal: 1 "=3V Horizontal: 1 "=30' Horizontal: 1 "=30' Vertical: 1 "=3' Vertical: 1 "=3' Vertical: 1 "=3' Vertical: 1 "=3' Vertical: 1 "=3' 90.0 90.0 89.0 _ _ 89.0 90.0 on n ee n ProG de Existin I Grade no n 89.0 88.0 87.0 86.0 85.0 84.0 83.0 82.0 81.0 80 0 Proposed G de Existin j Grade 8" Fire Main 4" Water Main 7 �! 18" 83.84 Proposed GradeJ Existin Grade 8" 1 Ire Main 8" Sanitary Sewer Proposed G de Existin 3 Grade CID 4" Water Main 8" Sanitary Sewer Detail #11 Detail #12 Detail #13 Detail #14 Detail #15 Horizontal: 1 "=30' Horizontal: 1 "=30' Horizontal: Horizontal: -I 30' Horizontal: -I 1 30' Vertical: 1 "=3' Vertical: 1 "=3' Vertical: 1 "=3' Vertical: 1 "=3' Vertical: 1 "=3' 90.0 90.0 89.0 88.0 87.0 86.0 85.0 84.0 83.0 82.0 81.0 80.0 79.0 7a In Pposed Grade Existin g Grade 18" ADS 83.46 8" S nitary Saws Proposed Gi ado-\Existin j Grade g 8" Fire Main 4" Water Main Ax 18" ADS 83.41 7/7 *IV in. / 89.0 Existing Grade -/ Z-ProposDd Grade 88.0 o i .0 au.0 86•0 89.0 4" WateMain 85.0 88.0 84.0 87.0 83.0 86•0 82.0 85.0 81.0 84.0 80.0 83.0 8" Sanitary Sewe 79.0 82.0 78.0 81.0 77 In __ M In I -Proposed Grade Existin g Grade Fire ain 4" Water Main 18" \� in. / / sting Grade Proposed Grade - 18" ADS 8" Tnitary Sewe 12"Min. v Detail #16 Detail #17 Detail #18 Detail #19 Detail #20 Horizontal: 1 "=30' Horizontal:-0' Horizontal: 1 "=30' Horizontal: 1 "=30' Horizontal: 1 "=30' Vertical: 1 "=3' Vertical: 1 "=3' Vertical: 1 "=3' Vertical: 1 "=3' Vertical: 1 "=3' 1 Updated per new Site Plan. 07/15/10 No. Revisions Date 00 M M m -� C O N O ll tL N .- O ob o x Q O M O CO V- 4) +O� °D E Co � 8 �u N Z Z C �� •11 V M C T, w O ��m + CN L 0 C ■ ED Z to i2 C W `O c � m L o y 0. m Tr" E m Go 0 "0 V C IL O _ U � O U� 0 VJ C 0 -_ U m o rn N NCo O N a O U CD ^Cu C L xaL • aariosA. VEKqu6 - 06 NI le,`Zul u Date Drawn: YZY Checked: Scale: As Noted Dwg : Underground U614 Conflict Job No: 1372-10 Sheet 10B Of 27 Sheets --- l._ ---- -- - - l - - - ---- — ` L ----- --- ----11- ! a'.:.I_ rn c v c v r m m a m N O O O N m E m 0 z v v FE O J d O� 3 v c v n. m in c 0 0 fN O+ C 'a E a a 0 i N n M O_ I N n M 3 ALARM LIGHT _ HORN _ SILENCE HORN CONTROL PANEL MECHANICAL 0 INTERLOCK 0 H-� A R ALT. oR 8' CBM CBE WIRE WAY Cal C62 'CAPACITOR' PACK I N MOTOR STARTERS (IF REO D) B� VVIRE WAY OIL On. TB2 GRD 0 0 BACK PLATE LIGHTNING ARRESTOR EMER. GEN. O POURED O MOUNTING EYES SEAL OFF (GAS TIGHT) J BOX TEMINAL STRIP CABLE CLAMPS (STRAIN RELIEFS) PUMP AND FLOAT CORDS INTERLOCK RUN SEAL RUN /\/.�.� OETM n CBM CBE HOA HOA O O GFI RECP. DEAD FRONT REMOVED FOR CLARITY FLOAT PUMP CABLES POWER CABLES CONTROL PANEL 1.) Shall be a NEMA 3R fiberglass enclosure with attached junction box with gas tight poured seal -off. 2.) Shall conform to Florida DEP codes Chapter 62-604. 3.) Panel shall be UL listed. 4.) Required Components: (1) Main Breaker (1) Neutral Block (1) Emergency Breaker (2) Hand -Off -Automatic Switches (2) Motor Breaker (2) Run Lights (1) Lightning/Surge Arrestor (2) Elapsed Time Meter (2) Motor Starter w/Overload Protection (1) Alternator (1) Generator Receptacle (1) Phase/Voltage Monitor (1) GFI Duplex Receptacle (1) Ground Bar (1) Alarm Light (2) 20 Pin Terminal Strips (1) Alarm Horn (1) Capacitor Pack (single phase only) (1) Alarm Silence Button (1) Control Power Transformer (480 volt only) GENERAL CONSTRUCTION NOTES: 1.) STATION: Shall be manufactured and assembled to the following criteria and supplied complete and ready for installation or approved equal. 2.) WETWELL: Shall be a V-0" inside diameter fiberglass reinforced manhole, consisting of isopthalic polyester resin with fiberglass chopped, strand, and continuous reinforcements built up to a minimum wall thickness of 3/8". Joints and pipe openings shall be laminated to provide a monolithic structure. 3.) GOVERNING STANDARDS: ASTM D-3753 (Standard Specification for Glass Fiber -Reinforced Polyester Manholes), ASTM C-581 (Chemical Resistance Testing), and ASTM C-582 (Plastic Laminate Standards). 4.) PUMPS: Shall be submersible non -clog pumps. Each pump shall slide on stainless guide rails when hoisted by a 1/4" stainless steel lift cable for easy inspection or repair without personnel entering the wetwell. Pump must be capable of passing 3" solids. 5.) VALVES: Check valves shall be stainless steel spring or side weighted lever. Plug valves shall be Dezurik or approved equal. 6.) PIPE & FITTING: Shall be 4" DIP 7.) LEVEL SWITCHES: Shall be Anchor Scientific liquid level regulator with sewage resistant electric cable. 8.) WETWELL TOP AND ACCESS DOOR: (150 PSF Rated) Shall have a clear opening of 30" x 48" and sufficient clearance of all equipment installed in the wetwell. The wetwell top, access door, and supporting frame shall be fabricated of T-6061 Aluminum. Frame shall be of sufficient thickness and strength to support the pump guide rails and the 316 stainless steel float hanger. Covers shall be provided with a lifting handle and saftey latch to hold the door in the open position. Locking hasps shall be furnished. Stainless steel hinges and hardware shall be used throughout. 9.) VALVE BOX: H-10 loading 48" x 48" x 36" with 48" x 48" top. Shall be made of fiberglass composite construction, 10.) CONTROL PANEL: Shall be a NEMA 4X Fiberglass enclosure and securly mounted on an aluminum T-post. Control panel shall meet Florida DEP requirement, Zephrhills lift station requirements and UL listed. PUMP STATION OPERATION/ CONROL PANEL LOGIC This pump station is designed to operate on a standard 4 float system. (F1, F2, F3, F4). The control logic is as follows: 1) Float switches are placed in the wetwell at levels determined by engineer. We recommend Pump Off (F1) be set at approximately top of pump or above. This keeps pump motor submersed in fluid for cooling purposes. F4 High Water Alarm F3 Lag Pump On F2 Lead Pump On F1 Pump Off Fluid enters wetwell and level rises up to "Lead Pump On" (F2). As float F2 tips, contacts close and Lead Pump is turned on. Fluid is then pumped out until level reaches Off float(F1). Contacts in F1 open and pump shuts off . Alternator relay is energized and switches from Load 1 to Load 2. ( Pumps alternate each fill cycle) Fluid continues to fill wetwell and again rises to Lead Float (F2). This time pump in Load 2 position comes on and pumps down wetwell. If one pump running can not keep up with inflow, the fluid level continues to rise until it reaches Lag Float (173) This float turns on the 2nd pump and both pumps will run until fluid level reaches F1, and both pumps are turned off. If both pumps running do not pump down wetwell the fluid level rises to High Water Alarm level float (F4), This float turns on red alarm light and alarm horn. Alarm horn can be silenced by pushing in the "Alarm Silence Button" located just under the horn on side of enclosure. The alarm light will remain "on" until the fluid level is lowered. 6x6 CONC POST Electrical Control Alarm Lite Panel II it �I I Panel Rotated For Clarity Alarm Lite DO- Horn Silence Horn Junction Box w/Poured Seal off (Gas Tight) Alum. Post Placed - In Concrete INVERT ELEV. ALARM ELEV. LAG PUMP ON ELEV. LEAD PUMP ON ELEV. OFF ELEV. 72" Dia. Fiberglass Wetwell 77.0 76.5 75 72.5 BOTTOM ELEV. 70.0 30" x 48" Aluminum Hatch Cover With Stainless Hardware 6' Diameter Fiberglass Wetwell w/Hatch Control Panel ALUM. LID =LEV. TOP 90.5 Seal Stainless 11 Cable Holder 78" Round Alum Top 1 /4" Tread Plate 6' Dia. A � o 1 1 r° �2 2� ,. 2" 1 1 Grout fillet all around 4" PVC Vent w/Screen NOTES: 1) Control panel shall not face hatch cover of wetwell 2) Water service with hose bib and backflow prevention device shall be provided. 3) All wiring shall be copper and shall meet all NEC and manufacturers requirements. 4) Control panel and top slab shall be located above the 100 year flood elevation. 5) Wetwell access cover and control panel shall be padlockable. 6) Control shall have audible and visual alarm system, motor overload phase / voltage protection. 7) Electric service cable and conduit sized as per NEC and local requirements. 8) System shall be operated and maintained so as to provide uninterrupted service as require d by chapter 62-604.500 (FAC). 9) Approved operation and maintenance manual shall be kept available at a site acceptable to the Florida D.E.P. for use by operation and maintenance personnel and for inspection by D.E.P. personnel. 10) All fastners inside wetwell shall be stainless steel. 11) Pump station shall be constructed in accordance with City of Zephrhills Requirements. 48" x 48" x 36" CDR VALVE BOX ALUMINUM TOP 48" x 48" DOUBLE DOOR 300 P.S.F. LOADING + + ♦ + ♦ ELEV. FINISHED GRADE 90.5 FLANGED VALVES CHECK VALVES TO BE STAINELSS STEEL OR SIDE WEIGHTED LEVER PLUG VALVES TO BE DeZURIK OR APPROVED EQUAL Stainless Lift Cable 4" DIP Discharge Piping Concrete ballast is not required. Contractor to keep excavation dry until backfilling activities have been completed. 70,00 4" x 4" CONCRETE POST STEEL PIPE STRAP ATTACHED TO POST. 3/4" HOSE BIBB 3/4" REDUCED PRESSURE BACKFLOW PREVENTER WITH VAC. ASSEMBLY. BREAKER y t d 6 -ANION TOP OF SLAB WATER SERVICE DETAIL (BY OTHERS) DESIGN CONDITION Model Hydromatic S4P H.P. GPM 160 @ TDH Voltage 230 Phase Impeller 8.25" Peak Flow Into Station = 83.96 GPM PUMP CURVE 7.5 LOCKABLE BALL VALVE oporadna Fort 16D WM facet TDH I - SYS711*1111111 head Curv* K*ad Characftdsik Cu v i 10.00 I 0.00 jL 0 00 5000 10000 16000 20000 26000 FLOW (II) IFI(�l T.�eYm �7��FiF1R� E�1i �.�1♦1 2 Updated per new Site Plan. 07/15/10 1 Per City comments. 05/08/08 No. Revisions Date O o co A Cn tt cc C u_ I* N T_ c C J` J p�j Q o O cc 0 CD LL m rn •- �V N Z t r _ W 'CO c 8 + 2 N rn Z ` C C W `O c a o � � cc a (q -E au ■ cc E m CAa co m CU "0 C CO C LL O Q_ CU O O �+ O " 0 U tp � v O CU _ CU C a . _ U Cl) s "CL Cl) O .cU N � L O U CkA, Eno ; er ; Cerio. Vasquez A684 ., November �1=1,' 2010 Date Drawn: YZY Checked: Scale: As Shown Dwg: Pumping Station Job No: 1372-10 Sheet 12 Of 27 Sheets • Cb 0) 0 M �b 90 w/ C�) C�) Existing Fire Hydrant C coo� IN) eA) to be Relocated • 158' --------------- t 1 11 -------------- ---------- I ----- ------------- r T "'Y 40 C) (9- End Phase I Trail Property Line CIO 88 - 8 7 -8 6 - - 861 90 - 8 7 .. . ....... Q) • 135' 50' 88 - ----- -240L 32 LF of 10' Trail - 4427 SY of Turning Lane and Driveway Future East ROW asphalt pavement A q 16 0 0 . . . . ...... A;f�r) CO . .......... - ----- �0 cv� 0 Q Q j 9 80'swale @ 0.5% 0) 429 LF of 10'Trail swe 0 @ 0.,5 -86 61 Future East ROW 10'Shoulder- 0 7� (0 60'swale 2.0% Q; Q) - - - - - - - - - - - - - - a..._--- - - 114,- - - - - - - - - - - - - - --- - - - - - - - - A 015 CO • C, Q) Ji _c). E VL Q) (b ew - - - - - - - - - --- - --- - - - - -- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ad ------------- C) Proposed Edge of,*vement Existing East ROW C)- 1�k 0) CO CO CO 0) 40 Q) 0-45---- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- - - - - - •CO LI) t7 ('V Relocated Fire Hydrant 42 LF of 6" DIP 70 11 2 - 90' Elbows 0)" 7 clob' Existing 12 "Water Main Existing 4" Force Main Ramp & Detectable !2 Existing Right -of -Way 46.3 LF of 12" Steel Casing Pipe Warning per FDOT Existing Pumping Station Jack & Bore per Pasco County Standards Index #304 (Typ.) 11,1119 SY of Widening Existing Edge of pavement 30 LF of Future 8"Water Main in Right -of -Way (See Utility Sheets for Details) Pavement See OffsiteDownmnnf Widening Detail 1 1. 1 14 LF of Proposed Type "D" -1: �- "bi - See I urning Lane and 18 LF OT Proposed 8 Water Main in Right -of -Way Curb Wet Tap Contractor to install \- Provide temporary construction water 4"x4" tapping sleeve and 4" service per Pasco County detail 01 Gate Valve. - Wet Tap Contractor to install 8"x12" tapping sleeve and 8" Gate Valve. NORTH Existing 12" Oak tree to be removed (see landscaping plans for details) II In 118 SY of pavement in the Right -of -Way 1�89.4o , Widening Detail Existing Sidewalk c- 1.50 See Offsite Pavement 3ij O DO \ OHP - OHP - GHP 0HP 0HP QHP90--'9 41P - GHP 70hp OHP P OHP C; - - - - - - - - - - - - - - - - - - --- - --1 -17 89.79 ... ..... ........ . ..... .......... .. ........ .......... ... . ..... .... . 90.69 90.52 90.09 E 9 1.78 90-32 0 Z Existing Edge of pavement 90.08 0 (b 69 0 .30 0 Existing Right -of -Way $9.4� • C .33 CL Proposed Edge of pavement 0I 04 ly C14 Existing Water Valve add concrete collar & raise box to match pavement elevation II 89 Existing North Right -of -Way Existing Edge of pavement - - -- - - - -- - -- - -- Aso--- - --- HP OHP ��P Ohl QHF HP'--}- Lill UHP ------- alp GHP QHP OHP UHP OHP HP Ulf` OHP OHP 89.75 89.70 -89059 89.18 90.10 0 CP 89.86 89.55 T --N 89.23 Driveway Pavement Future Wet Tap Detail Overlay existing pavement with 1" of FC - 9.5 asphaltic concrete along this length FORT KING ROAD (County Road) - Phase 1 j DAUGHTERY ROAD §i (County Road) roperty Line 5' Sidewalk Existing South Right -of -Way • 88.06 Detectable Warning per FDOT Index #304Sheet 6 of 6 (Typ.) Sidewalk NOTES: 1. No track type equipment will be allowed on any asphaltic or concrete surfaces. I I NOTES: 1. Turnout shall bo constructed in accordance with FDOT Index #515 2. Right turn lane shall be constructed in phase 1. 3. No track type equipment will be allowed on any asphaltic or concrete surfaces. 4. Safe pedestrian will be maintained at all times. 5. Any sidewalk, v�hich becomes undermined, must be removed and replaced. 6. Sidewalk connections to roadways must meet current A.D.A. standards per F.D.O.T. index 304. 7. Pasco County shall have no maintenance obligation in this area. 8. All traffic contro devices, i.e.; Warning / Construction type signs will comply with F.D.O.T. standard:3 during the construction phase. 9. All existing drainage to be maintained and restored to design flow lines. 10. No work, exce )t for emergency type, will be preformed after sundown and before sunrise. 11. NO OPEN CU FS without specific approval from the County Engineer. Trail Pavement Section 101-01, Broom finish 4 8" Su:)grade = 12" of Type B Stabilization with compacted subgrade to 98% MP (LBR 40) Turning Lane and Driveway Pavement Structural Course = 2.5" Asphaltic concrete (Type S-3) 1* Base = 6" of crushed concrete For additional detail see sidewalk details on sheet 19 Structural Number Required = 3.00 - Subgrade = 12" of Type B Stabilization with 2.5 x 0.44 = 1.10 compacted subgrade to 98% MP (LBR 40) 6 x 0.18 = 1.08 12 x 0.08 = 0.96 Structural Number Provided = 3.14 Offs1te Pavement Widening Friction Course = 1" FC 9.5 Structural Course = 3" Asphaltic concrete (Type S-3) Base = 6" of crushed concrete Subgrade = 12" of Type B Stabilization with compacted subgrade to 98% MP (LBR 40) Structural Number Required = 3.70 1 x 0.44 = 0.44 3 x 0.44 = 1.32 6 x 0.18 = 1.08 12 x 0.08 = 0.96 Structural Number Provided = 3.80 5 Revised offsite storm 09/30/10 pipe. Added notes. 4 Changed 5' sidewalk 08/31/10 to 10' trail. Added ditch & DBI on west side of entrance of Fort King Road. 3 Updated per new Site 07/15/10 Plan. 2 Revised per County 10/30/08 comments. 1 Per City comments. 05108/08 No. Revisions Date co 0- Cl) co -0 .r E 0 (D yj LL C: C: O 0 EL E 0 C: =3 0 -0 0 ( co UL) 0 =3 C: C: o 0) ::3 C: 0 >1 -r- -0 0Co a) N Co -o LL 4- CO 0 0 C) 0 LL Civil Engineer Carlos A. Vasquez, 20684 o November 11, 2010 Date Drawn: YZY Checked: Scale: 1 91=30' Dwg: III 060�4*, �u Job No: 1372-10 Sheet Of 27 13 Sheets 11 i 1 111 u GENERAL NOTES: 1. The contractor shall verify control point for line and grade prior to construction. 2. Location, elevation, and dimensions of existing utilities, structures, and features are shown in accordance with best information available at the time of the preparation of the plans but do not purport to be absolutely correct. 3. The contractor shall verify the location, elevation, and dimensions of all existing utilities, structures, and other features affecting his work and shall comply with all state, county, and local ordinances and obtain any necessary work permits that may be required prior to construction. 4. The contractor shall be responsible for the complete coordination of construction scheduling between the contractor and all utility agencies. The contractor shall adjust his schedule to coincide with other required utilities. 5. The engineer reserves the right to perform quality assurance testing on all materials delivered to project. 6. In the event unsuitable material is encountered during excavation, it is to be removed from the site except that it may be used to flatten slopes in areas approved by the engineers. 7. Overall cleanup shall be accomplished by the contractor in accordance with county standards or as directed by the engineer. Any and all expenses incurred for this work shall be included in the unit price bid for other items. 8. The contractor shall endeavor to protect private property. Any damage caused by the contractor in the performance of his work shall be corrected to the satisfaction of the engineers at the contractor's expense. Payment shall not be made for this work. 9. Any damage to state, county, or local roads caused by the contractor's equipment and operators shall be repaired by the contractor to the satisfaction of the engineer. Payment shall not be made for this work. 10. Any U.S.C. and G.S. monument within limits of construction shall be protected by the contractor. If in danger of damage, the contractor shall notify: Director, Charting & Geodetic Service 6001 Executive Blvd. Attn. C172 Rockville, Maryland 20852 Phone, (301) 433-8319 11. Construction of potable water and sanitary sewage systems are to include connection to existing facilities as shown. 12. Whatever material or construction item specifications are not specifically covered by these plans, the County of Pasco, Florida, or directed by the engineer, "The Florida Department of Transportation Standard Specifications for Road and Bridge Construction" latest edition, shall apply. 13. All construction work, including roads, drainage, and utilities, shall be constructed in accordance with pasco County design standards and tested in compliance with the pasco County Engineering Services Department's Testing Specifications for Construction of Roads, Storm drainage, and Utilities. 14. The contractor shall coordinate with all utilities and any other contractors. 15. Florida statute requires a minimum of 2 days and a maximum of 5 days no ' e before a contractor may excavate. The contractor shall call Sunshin State One Call (811) before commencing excavation. 16. Compaction for pipe backfill shall comply with AASHTO and Pasco county. 17. All fill up to the spring line of the pipe must be hand tamped. 18. Contractor shall submit to the engineer and/or architect for review, 4 copies of shop drawing on bid items (fire hydrants, valves, pies, inlets, manholes, pumps, control panels, light fixtures, plumbing fixtures, etc.). The contractor shall allow a minimum of 7 days for review of shop drawings. Approval of shop drawings is required prior to installation or construction. Substitution of specified items, if requested, will be evaluated by the project engineer. 19. It shall be the contractor's responsibility to notify (48 hours in advance) the engineer, utility company and regulatory agency for all inspections. It shall be the contractor's responsibility to supply results of all tests, in accordance with the testing schedule to the engineer prior to commencing the next phase. The tests required shall be performed by an independent testing laboratory approved by the owner and cost for the testing shall be paid for by the contractor and said cost will be included in the bid price. 20. The contractor shall contact the engineer's office immediately on any conflicts between what is shown herein and actual condition discovered during construction of any improvements shown on the drawings. 21. Prior to beginning work, the contractor shall expose all existing utilities to be extended or crossed. Any conflicts and the contractor's proposed resolutions shall be brought to the engineer's attention for approval. 22. All practicable effort shall be taken during construction to control and prevent erosion and transport of sediment materials to inlets, surface drains, wetlands and lake areas. The contractor shall be responsible for all restoration efforts that may be required. 23. The contractor is to control all fugitive dust originating on this project by watering or other methods as required. 24. The contractor shall not enter upon or in any way alter the wetland/conservation areas that may be on site. All work in the vicinity of open water and/or wetlands is to be performed in compliance with the environmental regulations and/or permits for the wetland/conservation areas that may be on site. The contractor will be responsible for any fine resulting from his violation of any regulations or permit conditions. 25. All disturbed areas shall be seeded and mulched, unless otherwise. 26. Contractor shall provide a two feet wide strip of sod adjacent to curb or pavement installations. 27. It is the responsibility of the contractor to establish in the field right of way lines, base lines, bench marks (elev.), center lines, and stationing as required to construct the project. 28. Contractor shall coordinate and reimburse the appropriate overhead utility company for the required support of utility poles where construction may cause the pole to lose it's self supporting ability. 29. Special pipe foundations, if required, shall be determined in the field and the type required will be as directed by the engineer. 30. Finished grade for ground elevations on drawings refer to grade after sodding. 31. All elevations are NGVD (1929). 32. All testing shall be witnessed by the engineer and the utility company representative. 33. Handicap ramps are to be constructed at all comers. 34. The constructor shall arrange for a final site inspection approval by the Engineering Services Department prior to issuance of the Certificate of Occupancy (CO). 35. The constructor shall notify the Pasco County Engineering Services Department at least two working days prior to commencing any activity on the site. 36. If, during construction activities, any evidence of historic resources including, but not limited to, aboriginal or historic pottery, prehistoric stone tools, bone or shell tools, historic trash pits, or historic building foundation, are discovered, work shall come to an immediate stop, and the Florida Department of Historic Resources ( State Historic Preservation Officer) and Pasco County shall be notified within two working days of the resources found on the site. 37. If, during construction activities, any evdence of the presence of State and Federally protected plant and/or animal species are discovered, work shall come to an immediate stop, and pasco County shall be notified within two working days of the plant and/or animal species found on the site. 38. If a Pasco County Global Positioning System (GPS) network point is located within the boundary of the site or within 50 feet of the same, the point shall re-established using GPS methods and "Blue Booked" prior to the issuance of any Building Permits or the recording of any plat. Proof of the said Blue Booking shall be submitted to the County Surveyor prior to the issuance of the said permit or the recording of the said plat. If it is discovered that the said point has been destroyed by construction, then the owner/developer of the land will be responsible for payment to Pasco County in the amount of $5,000.00 each. 39. Two unique and/or independent comers on the boundary of the subdivision plat shall have State plane coordinates noted on them and shall be tied by bearing and distance to the current GPS network. The coordinates for the said comers shall be noted on the plat. STORMWATER NOTES: 1. Stormwater metal pipe will not be allowed on this project (as noted on plans). 2. All drainage detail are to be Pasco county current standards. Where the County has no standard, FDOT current standards shall be used. This includes, but is not limited to: inlets, manholes, endwalls, flared end section, etc.. Non-standard drainage detail ( if any) are shown on detail sheets in the plans. 3. Pipe material shall comply with ASTM C76, "specifications for reinforced concrete culvert, storm drain, and sewer pipe; class III. Provide bell and spigot type pipe. 4. Corrugated metal pipe shall be galvanied stall plate in accordance with AASHTO M 167, with 2%"xY2" corrugations and a thickness of 0.06". OPERATION AND MAINTENANCE NOTES: 1. Control structures shall be visually inspected and shall be kept free of of any obstructions. The inspections are to be performed prior to the start and at the end of the rainy season. 2. Concrete weirs shall be visually inspected and shall be kept free of any obstructions. The inspections are to be performed prior to the start and at the end of the rainy season. 3. Inlet structures and storm pipes shall be inspected for accumulation of silt at the start and at the end of the rainy season. If the silt is found to be 3 inches or larger in thickness, it shall be removed and placed in upland areas. 4. Removal of native vegetation, including cattails, shall be prohibited within the wet detention ponds. 5. Dredging of wet detention ponds shall be prohibited. 6. The application of herbicides in the wet detention ponds shall be prohibited. SANITARY SEWER NOTES 1. Where double wye connections will be used, it must not be less than six inch (6") pipe. 2. Sewer laterals will not be less than thirty inches (30") and no more than sixty inches (60") in depth unless property grade requires it. 3. All main trunk sewer lines will be no less than eight inches (8") in diameter. 4. All sewer lines that are P.V.C. must be no less than SDR 35, 3034 pipe. Any sewer line at depths of 12-18 feet must be SDR 26 and any sewer line below 18 feet must be C-900. 5. All sewer force mains shall be SDR 21, PR 200, DR25 or heavier wall pipe. 6. All sewer force mains shall be labeled with green stripes every two feet (7), have the word SEWER stenciled every two feet (7) or have detector tape marked SEWER LINE. Copper tracing wire #14, green in color, shall be installed on all Force Main sewer lines. 7. All sewer lines, valves and fittings on force main cannot be covered until it has been inspected. 8. When raising a Manhole to grade that is above top of existing Manhole, you must use clay brick k with portland cement, also when forming the invert in the bottom of Manhole you must use portiand cement along with clay brick if necessary. When a drop less than two feet (2') is inside of Manhole, you must make the invert so that there is sufficient slope, not to hold solids. 9. All manholes that are concrete shall be coated on the entire interior surface with epoxy coal tar Exterior coating can be Bitumastic coating. Fiberglass does not need coating. 10. Manholes shall be 4 feet in diameter, with a 5 inch wall minimum. 11. All pipe penetrations shall have rubber boots. WATER NOTES 1. All P.V.C. water pipe under two inches (2") in diameter will be Schedule forty (40), two inch (2"), can be CL200 SDR 21. All pipe four inches (4") and larger will be C-900, DRA8, bell & gasket. 2. All water meters for single service will be poly tubing, 200 PSI, no less than one inch (1"), no less than eighteen (18") and no more than twenty-four inches (240) in depth. 3. All water service lines will be terminate four feet (4') feet from the sidewalk. Each of these lines will have a gate valve or curb stop that is approved by the city no more than twenty-four inches (24") deep. 4. All six inch (6") gate valves for fire hydrants must be tied to the main water line for repair of fire hydrants. 5. P.V.C. tees and elbows will not be used on water main over two inches (2") located within the right -of --way. Any water line over two inches (2") located in the right-of-way will have cast iron or ductile iron fittings with mechanical joints and Meg-a4ug. 6. All water pipe lines will be tested at one hundred fifty (160) psi for no less than two (2) hours. 7. All main water lines will be a minimum of thirty inches (30") and a maximum of forty inches (400) deep. 8. All water lines will be labeled with blue stripes every two feet (2% have water line stenciled every two feet (2') or have detector tape marked waterline. Copper tracing wire #14, blue in color, shall be installed on all water lines. 9. Upon completion of construction, all water mains shall be flushed out, chlorinated and sampled for bacteria as per D.E.P. regulation. 10. All valves two inches (2") and larger will have a cement pad two feet by two feet by four inches (2' x 2' x 4") around top of valves for locating. 11. All thrust blocks for fittings will be pre -cast; poured in place thrust blocks will be considered on new lines. Meg -a -lugs can be used for restrainers as per A.W.W.A. Bell restrainers shall be used in accordance to size of pipe as to how many restraints are needed before each fitting. 12. Where fire hydrants are required, water lines cannot be less than eight inches (8"), F.H. (5 Y. opening). 13. All water line and fittings cannot be covered until inspected. 14. All fire sprinkler systems must have a double check detector assembly valve before fire sprinkler system goes into any building, as per D.E.P. Chapter 62.555.360. Acceptable types of double check detector assembly valves are: Febco Watts Hershey Ames Wilkins Conbraco SUBMERSIBLE LIFT STATIONS NOTES 1. Provide lightening arrester (G.E. or approved equal) ahead of the control panel. 2. NEMA 4 x weatherproof dead front electrical panel fabricated of aluminum, stainless steel of fiberglass mounted on reinforced concrete post using stainless steel or aluminum bracket.s Provide lock thumb twist and lock clip. Size of panel will be no less than 24" x 24". For larger starters, size of panel must accommodate with extra space around starters. 3. Install electrical junction box below control panel with gas tight seal; gas seal for motor leads and gas seal for floats. 4. Flashing red alarm light with guard shield. 5. Provide emergency generator receptacle with double throw switch. Receptacle shall be Leviton #460R9W for up to 60 amps. Receptacle shall be Leviton #4100R9W for 60 to 100 amps. 6. Provide reset and elapsed time meter for each motor in dead front control panel and running lights, HOA switches. Magnetic starters will be Square D. Altemating relays will be diversified #ARA-120 ACA. Phase monitor shall be diversified. 7. All electric wiring shall be copper, and identified. 8. An electrical schematic diagram shall be submitted with plans or shop drawings and manuals. 9. Wet well shall be concrete or fiberglass. When concrete is used, it must have coating of Sauereisen SewerGard that is an aggregate -filled epoxy material or equal Inside wet well. 10. Valve vault shall be concrete or concrete block with gravel floor or drain. 11. Provide continuous top slab over wet well and valve vault. (Expansion joint may be provided between wet well and valve vault top). In some cases a space can be provided between wet well and valve vault. 12. Provide aluminum (Bilco or equal) frame and access hatches large enough for pump removal. 13. Water tight seals shall be provided where pipes pass through the wet well wall. 14. A nipple and valve shall be mounted on each pump discharge line ahead of check plug valves. 15. Check valves shall be stainless steel spring or side weighted lever. 16. Plug valves shall be DeZurik or approved equal. 17. By-pass connection for auxiliary pump shall include a four inch (4") plug valve and Kamlok female adaptor and a plug for exposed connector. 18. Motors shall be three (3) phase, without phase converter. 19. Stainless steel nameplate for each pump shall indicate the capacity, TDH speed and efficiency. m (minimum) which m I f in t least three inch 3 20. There are two u u ch must be capable e o ass a s pumps ( ) P passing ( ) solids and pump a minimum of one hundred (100) GPM. 21. Provide stainless steel guide rails. 22. All chains for lifting pumps up side rails will be galvanized no less than 5/16" links. Stainless steel cable will be accepted. 23. Provide four inch (4") screened vent pipe or other approved means for wet well ventilation. 24. Proper grading and landscape. 25. Components must be available locally. 26. Meets electrical codes. (Phase and ground fault circuit protection) 27. All switches and components must be properly labeled. 28. Pull pump to check for proper removal and seating. 29. Check pump cycling and check back-up pump. 30. All steel or metal in wet well will be painted with a paint that resists rust. 31. All bolts on fittings in wet well shall be stainless steel including mounting bolts for pump bases. 32. Permanent wet wells shall be no less than six feet (6') in diameter. 33. Draw down in wet wells shall be no less than four (4) feet. 34. Install convenient 110 volt receptacle on inside door on a separate 20 amp. circuit breaker. TESTING SCHEDULE GUIDE ITEM TEST TEST INDENTIFICATION TEST REQUIREMENT TEST FREQUENCY EMBANKMENT MAXIMUM DENSITY AASHTO T180 N/A PER SOIL TYPE OPTIMUM MOISTURE ASTM D1557 FIELD DENSITY AASHTO T191, T204, 95% OF MAXIMUM ONE PER 500 L.F T238 DENSITY HORIZONTALLY; ASTM D1556, D2937, ALTERNATING LIFTS (1 FT) D2922 UTILITY MAXIMUM DENSITY AASHTO T180 N/A PER SOIL TYPE TRENCH BACKFILL OPTIMUM MOISTURE ASTM D1557 98% OF MAXIMUM ONE PER 500 L.F HORI- UNDER ROADWAYS AND FIELD DENSITY AASHTO T191, T204, ZONTALLY; EVERY 2' STRUCTURES T238 DENSITY VERTICALLY D2922 ASTM D1556, D2937, AT LEAST ONE FOR D2922 EACH PIPE RUN BACKFILL OF STRUCTURES MAXIMUM DENSITY AASHTO T180 N/A PER SOIL TYPE OPTIMUM MOISTURE ASTM D1557 FIELD DENSITY AASHTO T191, T204, 98% OF MAXIMUM EVERY Z VERTICALLY T238 DENSITY ASTM D1556, D2937, D2922 ROADWAY SUBGRADE BEARING VALUES LBR-FLA, D.O.T. LBR=40 MIN ONE PER SOIL TYPE CHECK POINT LBR AT 500 MAXIMUM DENSITY AASHTO T180 N/A L.F. HORIZONTALLY OPTIMUM MOISTURE ASTM D1557 ONE PER SOIL TYPE FIELD DENSITY & AASHTO T191, T238 98% OF MAXIMUM THICKNESS ASTM D1556, D2922 DENSITY ONE PER 500 L.F HORI- BUILDING PADS MAXIMUM DENSITY AASHTO T180 N/A PER BUILDING PAD OPTIMUM MOISTURE ASTM D1557 FIELD DENSITY AASHTO T191, T204, 95% OF MAXIMUM AS DIRECTED BY SOILS T238 DENSITY ENGINEER ASTM D1556, D2937, D2922 ROADWAY BASE BEARING VALUES LBR-FLA, D.O.T. 100% LBR-FLA, D.O.T. ONE PER SOURCE OR AS MATERIAL CHANGES CK. PT. MAXIMUM DENSITY AASHTO T180 N/A LBR AT 500 L.F. HORI- OPTIMUM MOISTURE, ASTM D1557 ZONTAL ONE PER SOURCE THICKNESS, AASHTO T191, T238 98% OF MAXIMUM FIELD DENSITY, ASTM D1556, D2922 DENSITY ONE PER 500 L.F GRADATION AASHTO T27, T89, T90 PER SPECIFICATIONS HORIZONTALLY ONE PER SOURCE ATTERBERG LIMITS ASTM C136, D423, D424 SOIL CEMENT BASE* MIX DESIGN PORTLAND CEMENT PER SPECIFICATIONS ONE PER SOIL TYPE ASSOC. SPECIFICATIONS MAXIMUM DENSITY AASHTO T134 N/A ONE PER SOIL TYPE DAILY OPTIMUM MOISTURE, (STANDARD) 300 PSI AT 7 DAYS ONE SET PER SOIL TYPE COMPRESSIVE PORTLAND CEMENT DAILY STRENGTH SPECIMENS ASSOC. SPECIFICATIONS TEST CORES PORTLAND CEMENT 450 PSI AT 21 DAYS ONE SET OF 3 CORES PER ASSOC. SPECIFICATIONS COMPRESSIVE STRENGTH SPECIMENS FIELD DENSITY & AASHTO T191, T238 95% OF MAXIMUM ONE PER 500 L.F THICKNESS ASTM D1556, D2922 DENSITY HORIZONTALLY ASPHALTIC CONCRETE MATERIALS QUALITY PER F.D.O.T SPECIFICATIONS BITUMEN CONTENT AASHTO T164, T30 PER SPECIFICATIONS ONE PER DAY GRADATION ASTM D2172 98% OF LAB DENSITY ONE PER 500 L.F FIELD DENSITY ASTM D02950-81 HORIZONTALLY LOS ANGELES AASHTO T96-77 ABRASION THICKNESS ASTM C131-81 PER SPECIFICATIONS ONE PER SOURCE N/A PER SPECIFICATIONS ONE PER 500 L.F CURB & ROADWAY SLUMP TEST AASHTO T119-82 PER SPECIFICATIONS AS DEEMED NECESSARY CONCRETE ASTM C143 BY SOILS ENGINEER. TESTS MAY BE RUN BY THE SOILS ENGINEER OR HIS REPRE- TIVE. COMPRESSIVE AASHTO T23-80 N/A SSENT ONE ONE SET 3 CYLINDERS STRENGTH ASTM C31.69 FOR 50 CUBIC YARD OF CYLINDERS 3000 PSI Q 28 DAYS FRACTION THEREOF PER DAY INCLUDES ONE SLUMP TEST ' CONTRACTOR SHALL NOT PAVE OVER SOIL CEMENT BASE UNTIL A 30 DAY CURING TIME HAS ELAPSED. •` TEST SPECIFICATIONS & FREQUENCY MAY BE ALTERED BY THE SOILS ENGINEER. ASPHALT PAVING NOTES: 1. The areas to be paved shall be graded to provided necessary drainage. 2. The subgrade shall be compacted to provide a minimum compacted densiyt of 98% of maximum density as determined by modified proctor (ASTM. subgrade). 3. The surface shall be clean and dry. Prime coat shall be approved cutback asphalt (RC-70 or RC-90) and temperature when applied by means of a pressure distributor at the rate of approximately 0.1 to 0.25 gallons per square yard. 4. An asphalt concrete analysis (to guarantee compliance with Pasco County specifications) shall be conducted by an independent laboratory, and the final report submitted prior to final acceptance. 5. All asphalt work shall conform to Pasco County standards. 6. All roadway construction ( including pavement marking and signage ) and material testing shall comply with roadway standards and specifications of the Pasco County Land Development Code. 7. Base and backfill materials shall be either of the same type and composition as the material removed, or of equal or greater structural adequacy. Material contaminated with deleterious substances during excavation shall not be used 8. The area above the trench above the pipe zone and below the base course must be backfilled and compacted in layers not to exceed twelve inches, except that the last two lifts shall not exceed six inches per lift. 9. If roadway section has a shoulder, the shoulder shall extend eight feet from edge of pavement. Use LBR 30 (or better) back fill material in the top 24 inches of trench. BIDDING NOTES: 1. Bids will be due in the office of The Richman Group of Florida, Inc. 2. The contractor shall supply all construction stakeout and as -built surveying of the project. As-builts shall consist of a complete set of record drawings prepared by a professional land surveyors (supplied by the contractor) and shall include, but not be limited to: storm sewer system; inlets; manholes; piping locations; all pipe invert; manhole and inlet tops; potable and refuse water line locations off r/w; service lateral locatoins; sanitary sewer manholes; pipe inverts; roadway center line elevations; curb flow line elevations. Owner's surveyor will supply horizontal and vertical controls, only. 3. The information provided in these plans is solely to assist the contractor in assessing the nature and extent of conditions which will be encounter during encountered du g the course of the work. The contractors are directed, prior to bidding, to conduct whatever investigations they deem necessary to arrive at their own conclusion regarding the actual conditions that will be encountered, and upon which their bids will be based. 4. The contractor is responsible for the coordination and cost of all required testing and inspections of the project. Contractor shall notify owner and engineer of all inspections requested from Pasco County, FDOT, or SWFWMD 24 hours prior to request. The contractor shall invite the owner and the engineer to all scheduled inspections required by any reviewing agency. 5. Questions on quantities, quality or materials which could change the contract price should be brought to the attention of the engineer prior to bidding. All questions will be answered and copied to all bidders. 6. The contractor shall contract with and direct a local testing laboratory for all required on on site tests such as: concrete strength, slump, densities, or LBR of roadbeds, etc. Copies of all tests shall be sent to the engineer and owner within 72 hours of the tests. 7. This is a lump sum bid. Schedule of values is required for additions and deletions to the scope of work or progress payments. 8. Seed & mulch will not be required on the lot areas. All slopes 4:1 or greater shall be sodded. Bahia will be used. 9. Contractor shall supply all the equipment, material and personnel required for all testing. 10. The site contactor shall grade lots within 0.5' tolerance. However, no area shall be allowed to be lower more than 0.2'. Site contractor shall provide an as -built survey of the graded lot with a minimum of two shots per lot at locations selected by the engineer. 11. The compaction of all lots in phases shall be tested at varying depths. The compaction testing of all lots shall be performed on 1/4 of the lots at locations selected by the engineer. All lot fill shall meet 95 percent of the modified proctor. 3 1 Revised notes. 000110 2 Updated per new Site Plan. 07/15/10 1 Per City comments. 05/08/OS No. Revisions Date i M ro 3 M � C o LL ti N ob L J o :3 X Q m N 0 � m M E InCS low N C Z � c .��w M N o4r- + CN .t32C Z ` rn a- C LU `O c n o u m a�?a t0 LL O CU CD O O O V CO U:r_- 0 0) :3CU U ch C O .� U N_ s C A CU O (Q _c N N N 4-' O 4- o Z U r' "v wlt q arios Vasquez 2 84 Novirmber+41;'�010 Date Drawn: YZY Checked: Scale: As Shown Dwg : Notes and Testing S( edi Job No: 1372-10 Sheet 16 Of 27 Sheets III i I i i I 1 1 1 1 1 W 111rrM111111111 Is Vim!' 1 1 11 I Prope�y line 90 NO V F"If PER 8 — — — — — — — Too Bank El. 86.00:, � � 4, x u m 85 84 83 82 81 80 79 92 91 90 89 88 87 88 85 84 83 82 81 C 1V1 1 Va aV I- 4 7 Scale: 1 "=6' 4 Added phase 2 construction water- marks update pond E. 08/31/10 3 Updated per new Site Plan. 07/15/10 2 Update per SWFWM comments. 09/24/08 1 Per City comments. 05IM08 No. Revisions Date Co "O oar Co U ) O L V U U) C i1 UCO) c o CL u a O CU = N LL 13' o U A ri&�,A esqu�. '20684 Novenits�i� b1; 010 Date Drawn: YZY Checked: Scale: As Shown Dwg : Pond Section and Details Job No: 1372-10 Sheet 17 Of 27 Sheets _ .. I L_ 11 7.. 1 --A_� o� C r a r r m EL 00 N M N 0 s N m a E 0 0 z FE 0 v O J a_ 3 ai 'o m 0 m rn 0 .o 0 v m o� a Jd a. 0 N r` M 0 N t` M 3 LOW A W A ►��� �T—ram Top View Note: All dimensions are nominal PE threaded rod with wing nuts and spacers see note Right Side View Front View PART # PIPE SIZE A B (Max) H L W 121ONP 12in 6.5in 10in 6.5in 251n 29in 151ONP 15in 6.5in 10in 6.5in 25in 29in 181ONP 18in 7.5in 15in 6.5in 32in 35in 241ONP 24in 7.5in 18in 6.5in 36in 45in 301ONP 30in 7.5in 12in 8.6in 58in 63in 736IONP 36in 7.5in 25in 7 8.6in 58in 63in 2" Raised Or Depressed Indentification Letter 2" Raised Or Depressed Indentification Letter (WT.) Bottom View Section 2" Top View 5" 8 Section Flared End Section N.T.S. Pick -Up Hole Non -Skid Surface Top View All Reinforcement No. 6 Bars Except 648 Bars Shown. Bars Spaced @ 6" Centers Both Ways Except Middle Bars Shown @ 7" Centers. All Bars With ACI Standard Hooks Canted Approx. 45", Or Embedded In Accordance With The Slab Reinforcement Detail Shown Under Optional Construction Joints. Sheet No. 3 Of 6, Except All #8 Ban; And #6 Bars Around Manhole Opening Shall Be Hooked. 2-#8 'ars 8" For 3'-6" & 4' Dia. 10" For 6' & 7' Dia. Structure Wall Section Type 7-T (Traffic) (H-20) Structure Top FDOT Index #201 NOTES (TOPS, FRAMES, AND COVER 1. All steel bars shall have 1 1/4" minimum cover unless otherwise shown and shall be hooked where indicated. 2. Manhole top Type 7 slabs shall be of Class II concrete. Concrete as specified in ASTM C-478 may be used for precast units; see General Note No. 2. 3. Manhole top Type 7 slabs may be of cast -in -place or precast construction. The optional key is for precast tops and in lieu of dowels. Frame and slab openings are to be omitted when top is used over a junction box. Frames can be adjusted with from one to six courses of brick. 4. Manhole top Type 8 may be of cast -in -place or precast concrete construction or brick construction. For concrete construction, the concrete and steel reinforcement shall be the same as the supporting wall unit. An eccentric cone may be used. 5. Manhole tops shall be secured to structures by optional construction joints as shown on Sheet 3 of 6. 6. The 212 lb. cover is to be used for all frames Types I, II & 111 and is the replacement cover for all previous frames with 1 1/2" deep seats (traffic type). The 185 lb. cover (non- traffic type), 1984 Roadway and Traffic Design Standards Index No. 201, is the replacement cover for existing frames with 1/2" deep seats. Installation of frames with 1/2" deep seats is not permitted. The 185 lb. covers are to be placed in existing 1/2" deep seated frames only when specifically called for in the plans or as specifically directed by the Engineer. Concrete Or 8" Brick. See Note 4. Section Type 8 Manhole FDOT Index #201 of curb or of pavement 0 ;t Line Post Corner Or End Post 12" 3' or 5' square MANDATORY White on Blue Background Chain Link Type "B" Fence 3 Updated per new Site Plan. 07/15/10 2 Update handicap detail. 06/13/08 1 Per City comments. 05/08/08 No. Revisions Date O) 00 M A M N C O .2 ILL LL ti N Cb o o cXo Q m LL o M E cc ` Cl)� mz0�v =mmmp C �— �� W ono c ♦ c a = La fin a c W u U-) a� cEo o y a -. p ,n „ ....CU ,^ O I` C LL '^ - Sidewalk ramp shall have ICU" C W Detectable Warnings per FDOT 1'-6" O a Standard Index 304. See "Florida O C 0 Accessibility Code for Building Construction, latest edition. International Symbol U (,) � 3-6" White 5' Sidewalk irk of Access 16- U CU Chevron Equally Spaced Per Aisle MAX- MAX- See Note 7 left. }' Cl)White NC: cc "IU on Blue Background �_ 0 NI o o o 0 0 0 Z„ c " PARKING BY DISABLE White background Black V— 0 4 PERMIT Message Lettering N ONLY tU 111, 3/8" holes with holes drilled on 0 a 1" centers full length in full O (0 N Z'Wt „ „ 2" - 12 -0 „ o VIOLATORS WILL BE length in metal post. (Mount with 5/16" x 2 1/4" bolts, top �` (n FINED $250.00 and bottom of sign) >% 6" white s s V 6" blue 6" blue DISABLED PARKING / MARKING TYPICAL DETAILS Notes: 1. Metal post to be galvanized. All bolts, nuts, washers and screws must be rustproof. 2. Concrete for footing shall be portland cement and have a minimum compressive strength of 3,000 P.S.I. 3. Signs will be fabricated by using reflecting coating in the symbol, message and border applied to a sheet aluminum backing (.080) in thickness. 4. Message lettering shall be upper case (black)(series c) 1.5" high in accordance with manual on uniform traffic control devices. Except as noted on sheet 2 of 2. 5. The symbol is composed of two elements, a white wheelchair figure (which should always face right) on a square background, international blue in color (fed. Std. 595a, color #15180). 6. Sign post shall be min. 2'-0" clear from back of curb. The use of properly located bollards in accessible parking spaces. 7. Are acceptable substitutes for regular bumper guard. 8. Minimum number of accessible parking spaces shall be per florida accessibility building code section 4.6.3. o .J1,J.L ti 1 „ „1 VY Concrete Footing N.T.S 5/8 3 1/8" METAL POST l2" WT. of Blank post shall be 2-21/2"#/FT. SECTION A - A DISABLED PARKING / SIGNING � s 7, `(� 0 i E rc_ dos, -A-, a 'qu6Z 4 Novemb , q.a @`�010 Date® 4 Drawn: YZY Checked: Scale: As Shown Dwg: Site and Drainage Details Job No: 1372-10 Sheet 18 Of 27 Sheets 6" * Contractor to use fiberglass, galvanized steel or aluminum material for baffle. 30" Baff 6 O M Cast Iron per FDOT Inuvx # 232 6" Baffle* Top El. 87.14 Inv. El. 84.50 " co Bottom Pond 84.00 30" RCP/�� Inv El.81.94 I fI L— — —'--- —J Grout I Section E-E _► 2 Wide strip of 4" thick Soil cement running the length of the baffle (TYp•) Type "D" Modified --- rr%r%-r t Plan View 6" 3'-1" 6" Outfall Structure for Pond B Scale: 1 "=2' 4 . -A 30" RCP F 7-3/8" 1-3/8" 3,000 psi 3" 3" at 28 days - - - - 3" 11 5" r l• 2" a 244 Bars Cont. Dowel hole cast in 3/4" 0, 2 req'd per wheel stop Plan #4 Bar 12" in length Anchor rod, 2 req'd per wheel stop Profile 9'-0" Installation Detail Wheel Stop Details N.T.S. 1'-6" 2'-6" NOTE VENTED ENCLOSURE TO BE COLOR CODED AS FOLLOWS: WATER MAIN — BLUE FORCE MAIN — GREEN REUSE MAIN — PURPLE 7 FINISHED GRADE NOTE: PASCO COUNTY SHALL HAVE OPTION OF REQUIRING THE AIR RELEASE VALVE ASSEMBLY WITH ODOR CONTROL SYSTEM (DETAIL 5) TO BE INSTALLED WHERE ODOR MAY BE A CONCERN M A T E R I A L S ITEM QUANT. DESCRIPTION 1 1 VENTED ENCLOSURE, WATER PLUS CORP. MODEL #131632 2 1 AIR RELEASE VALVE 2" NPT (SEE BELOW) SEWER AIR RELEASE VALVES SHALL BE ARI MODEL D-025 WATER AIR RELEASE VALVES SHALL BE VALMATIC OR EQUAL 3 1 1" CURB STOP, S.S. 4 1 2" x 4" NIPPLE, S.S. 5 1 2" BALL VALVE, S.S. 6 1 2" TEE, S.S. 7 1 2" X 1" REDUCER, S.S. 8 1 1" SHORT NIPPLE, S.S. 9 1 2" PIPE, S.S. LENGTH AS REQUIRED 10 1 2" DOUBLE STRAP TAPPING SADDLE, S.S. 11 1 4" & LARGER PIPE D.I. OR PVC DR-18 12 1 2" CORPORATION BRASS 13 2 1-1/2" PIPE, PVC, LENGTH AS REQUIRED 14 1 1-1/2" x 90' ELBOW, PVC 15 1 CONCRETE SLAB AROUND ENCLOSURE 16 1 1 1#57 WHITE ROCK Grout STANDARD AIR RELEASE VALVE ASSEMBLY Section F-F (VERTICAL PIPE LAYOUT) EXPANSION JOINTS @ 24' O.C. TOOLED JOINTS @ 8' O.C. 1/4" x 1/2" TOOLED JOINT 1/2" EXP. JOINT MATERIAL LONGITUDINAL SECTION 3,000 psi concrete, broom finish, and saw cut control joints at 10' on centers. Constructed by FDOT Index #310 5' Sidewalk " *4" 2% Slope 2" 2" BROOM FINISH Well compacted soil SMOOTH FINISH TYPICAL SIDEWALK INVERT A( PLANS/ 10" Inline Drain N.T.S. Nyloplast 10" Inline drain • "~ ' ^" Pedestrian Light Duty th Locking Device 10" ADS Adapter for corrugated Pipe or Approved Equal 10"x4" or 15"x4" ADS Tee Finished grade Downspout ADS 4"x4.25"x3" Downspout adapter inserted in riser pipe Injection molded Wr 90• bend ADS 4" perforated pipe w/ sock Roof Drain Connection Detail N.T.S. *4f Building face 2 Updated per new Site Plan. 07/15/10 1 Per City comments. 05/08/08 No. Revisions Date N �L O O a. a) O o 0 U 0 i 0 U C;) ICU ch CU C "Cu � C 0 . ve 0 CU 0 = N — O U eed) ° ado9;i(�'. V Pt qulbz 2%84 Sr Novernb • •on� DOW v u Drawn: YZY Checked: Scale: As Shown Dwg : Site and Drainage Details Job No: 1372-10 Sheet 19 Of 27 Sheets c C } r m C 0 N 0 m E 0 z 0 0 0 a a ai 'v m 0 T N a O N CL 0 N M 0 i N n M i 3 v N WILKINS MODEL 975XL 1 1/2" CLUBHOUSE POTABLE WATER REDUCED PRESSURE BACKFLOW ASSEMBLY STEEL PIPE CASING MECHANICAL JOINT CASING SPACERS, (BIT. COATED) SEE WITH MEGALUG RESTRAINER INSTALLED PER MFG. PLANS FOR SIZE, OR RESTRAINED PUSH -ON RECOMMENDATIONS LOCATION & LENGTH JOINT BRICK & 1/2" PLASTER SEALS AT EACH END OF PIPE CASING MATERIAL S ITEM QUANT. DESCRIPTION 1 1 2" BACKFLOW PREVENTER ASSEMBLY, REDUCED PRESSURE ZONE 2 1 2" METER FURNISHED BY PASCO COUNTY UTILITIES 3 2 BRASS -METER FLANGES OR ADAPTORS 4 2 2" ELBOWS - GALV. 90' 5 2 2" RISER - GALV. 6 ■ CONCRETE SLAB 7 1 2" VALVE - BRASS OR S.S. 8 2 TEE/ VALVES - BRASS OR S.S. 9 1 2" GATE VALVE - BRASS OR S.S. 10 1 PIPE STAND (SUPPORT) 11 2 M.J. CAP WITH 2" TAP 6" CONCRETE SLAB 3 Added Open Cut Restoration detail. 09/30/10 2 Update per new site plan. 07/15/10 1 Per City comments. 05/08/08 No. i Revisions Date DITCH WIDTH (TW) + 4'-0" GRADE NOTE: NOTE: - CONTRACTOR/CUSTOMER SHALL APPLY AT PASCO COUNTY UTILITIES CUSTOMER SERVICE - CARRIER PIPE FOR WATER & REUSE MAINS SHALL BE CEMENT MORTAR LINED D.I.P. FOR TEMPORARY WATER SERVICE AT LEAST THREE DAYS PRIOR TO REQUIRED SERVICE DATE. 4 q "4 d CD - CARRIER PIPE FOR SEWER/FORCE MAINS SHALL BE GLASS FLAKE EPDXY (PROTECTO 401) Go SAW CUT 6" SURFACE REPLACEMENT TWICE 6" SAW CUT - THE METER WILL BE FURNISHED, INSTALLED AND INITIAL READING TAKEN BY PASCO COUNTY UTILITIES. (� �j Q Q Go OR POLYETHYLENE LINED D.I.P. THE ORIGINAL THICKNESS ALL FITTINGS, PIPING, VALVES AND MATERIALS INCLUDING THE PASCO COUNTY APPROVED REDUCED �I i I —III- �=r —I ( I - CARRIER PIPE TO BE COLOR CODED WITH PAINT STRIPES: SAW NOTE 1 PRESSURE BACKFLOW PREVENTION DEVICE SHALL BE FURNISHED AND INSTALLED BY THE _ WATER - BLUE CONTRACTOR/CUSTOMER.-�I-IIIOld E�II,�I C REUSE - PURPLE - CONTRACTOR/CUSTOMER FURNISHED REDUCED PRESSURE BACKFLOW PREVENTION DEVICE i, SEWER - GREEN LL I` N - CASING SHALL EXTEND 8' MINIMUM BEYOND EDGE OF PAVEMENT. MUST BE INSTALLED BEFORE THE METER IS INSTALLED BY PASCO COUNTY UTILITIES. THE APPROVED DIRECTION OF FLOW BACKFLOW PREVENTION DEVICE SHALL BE TESTED AND CERTIFIED BY PASCO COUNTY � Q TREPLACEMENT BASE UTILITIES CERTIFIED BACKFLOW PREVENTION TECHNICIAN AT TIME OF METER INSTALLATION. ._.. JACK & BORE CARRIER DETAIL o- w w - CONTRACTOR/CUSTOMER SHALL PROTECT THE JUMPER/METER ASSEMBLY FROM DAMAGE. Uj Of J x Q w N v w - CONTRACTOR/CUSTOMER IS RESPONSIBLE FOR BACTERIOLOGICAL TESTING AFTER CONNECTION CcC < N = of OF TEMPORARY WATER SERVICE. £• . e .,,.g Q \SEE � 6„ WILKINS MODEL 350DACO" NOTE 2 < v_> - TEMPORARY CONSTRUCTION JUMPER/METER ASSEMBLY SHALL NOT BE REMOVED UNTIL O� E cc SYSTEM IS ACCEPTED AND DEPARTMENT OF HEALTH CERTIFICATION AND CLEARANCE FOR DOUBLE CHECK DETECTOR ASSEMBLY t/� �4f F OF OUTSIDE LANE 1 -6 SERVICE FORM HAS BEEN RECEIVED BY PASCO COUNTY UTILITIES. C OR OUTSIDE TRACK M TYP. - WHEN THE NEW SYSTEM IS ACCEPTED AND THE FINAL METER READING TAKEN BY PASCO COUNTY, V N Z C (� THE TEMPORARY CONSTRUCTION JUMPER/METER ASSEMBLY MUST BE COMPLETELY Z C4 :3 10 SEE NOTE 2 VARIES 25' MIN. N REMOVED FROM M.J CAP TO M.J. CAP AND A NEW WATER MAIN IS TO BE M C 4)c J CHLORINATED AND INSTALLED COMPLETING THE FINAL CONNECTION. .~.1 W C oo w C� C STABILIZED CURB Q N - BY APPLYING FOR SERVICE, CONTRACTOR/CUSTOMER AGREES TO TAKE WATER SERVICE N + SHOULDER SEE NOTE 2 FROM PASCO COUNTY UTILITIES IN ACCORDANCE WITH THE APPROPRIATE RATE SCHEDULE,:, N SEENOTE 3 a ._ , ,�. , ... �.. .., ,, ...., ....;.� : .. _ _ . ....�:...., � , -» 3, „ ,,. :, ,.... � . «... ,,•:: � _ ` ROADWAY RAIL AND IN ACCORDANCE WITH PASCO COUNTY UTILITIES RULES AND REGULATION. O _ 'Q C 3'-0" MIN. Vcc N -E Q. TEMPORARY CONSTRUCTION WATER SERVICE CA a 00 m 3'-0" MIN. a SEE NOTE 4 a DITCH SUBBASE z z DIAMETER (D) VARIES 0 Z o 0 is p TRENCH WIDTH (TW): MAX = D+3'-O" a n l a D MIN. = D+2'-O" ao o T = THICKNESS OF MAIN I w ORIGINAL BASE 2'-0" SQUARE CONC. N TW PAD. 3000 PSI 4" THICK 6" X 6" W1.4 X W1.4 111 II {i GENERAL NOTES: N 1. REPLACEMENT ASPHALT SHALL BE TWICE THE ORIGINAL PAVEMENT VALVE TYPE t x THICKNESS WITH OF TWO (2) INCHES AND SHALL BE TYPE S-1 OR S-3 NEPTUNE 3" COMPOUND ASPHALT. WATER, SEWER, METER W/CONCRETE BOX MANUFACTURER Ovflo� REUSE, ETC. AND CAST IRON LID 2. REPLACEMENT BASE SHALL BE NEW MATERIAL NOT REUSED FROM G.V. WATER 12" MIN. EXCAVATION. ACCEPTABLE BASE ALTERNATIVE SHALL BE TYPE ABC OR STEEL PIPE CASING BETTER ASPHALT PLACED AT A TOTAL THICKNESS PF SIX (6)INCHES. SIZE CLOW Q� �OQ 30" MAX. BRICK & 1/2" PLASTER SEALS (BIT. COATED) SEE 8 6" CONCRETE SLAB GRADE AT EACH END OF PIPE CASING PLANS FOR SIZE, 3. AREA 1-BACKFILL SHALL BE PLACED IN SIX (6) INCH LIFT WITH EACH TESTS SHALL BE SUBMITTED TO PASCO 27 TURNS BRASS MARKER W/ LOCATION & LENGTH LIFT COMPACTED TO 100% OF FM1-T238 USING MECHANICAL TAMPERS. COUNTY ENGINEERING INSPECTIONS TURNS TO OPEN VALVE TYPE, SIZE AND VERIFYING OPEN CUT RESTORATION IS LT. TO OPEN NUMBER OF TURNS Q <7 CU 4. AREA 2-BACKFILL SHALL BE PLACED IN TWELVE (12) INCHES LIFTS PER GENERAL NOTES BEFORE RELEASE RIGHT OR LEFT TO OPEN q _ CARRIER PIPE CASING PIPE CASING WALL THICKNESS WITH EACH LIFT COMPACTED TO 100% OF FMI-T238, USING APPROPRIATE OF PERMIT OR GUARANTEE IF '� 4 (INCHES) (INCHES) (INCHES) COMPACTING EQUIPMENT. APPLICABLE. MATERIAL AND THICKNESS OPENING DIRECTION �L VERIFICATION SHALL BE REQUIRED. ALL SHUT OFF f NOTE: 5. AREA 3-LIMEROCK (LBR 100) BASE SHALL BE CONSTRUCTED IN LIFTS TESTING SHALL BE PASCO COUNTY R VALVE PAD INLET �I (j I w O 1. VERTICAL DIMENSIONS ARE TYPICAL FOR MAINS. 4 12 1/4 NOT GREATER THAN (6) INCHES COMPACTED THICKNESS, AND HAVE A SERVICES DEPARTMENT TESTING TYPICAL CONCRETE L E j vI 2. CASINGS SHALL TERMINATE 8' MINIMUM BEYOND 6 16 1 /4 SPECIFICATIONS FOR CONSTRUCTION OF !+ DENSITY EQUAL TO 100% OF FMI-T238, METHOD A. I { II II EDGE OF PAVEMENT. 8 16 1 /4 ROADS, STORM DRAINAGE AND UYILITIES; CU 3. CASINGS SHALL HAVE 30" MINIMUM COVER UNDER 10 24 5/16 6. FLOWABLE FILL MAY BE PLACED ABOVE AREA 1 UP TO THE BOTTOM OCTOBER 2006. O DITCH BOTTOMS AND 36" ELSEWHERE. 12 24 5/16 OF THE RESTORED BASE. MIX DESIGN SHALL CONFORM TO FDOTSS, FINISH GRADE DIRECTION OF FLOW a 4. GRAVITY SEWERS SHALL BE PROPERLY ANCHORED 16 30 3/8 SECTION 121. VALVE BOX PAD TO PREVENT FLOATATION WITH SPACERS ADJUSTED SEE DETAIL ) O O 0 '^ TO PROVIDE THE SLOPE REQUIRED. 20 36 3/8 4" MIN. (TYP. � v/ 5. SEE SECTION 6.2 FOR CASING SIZE. 30 48 3�8 OPEN CUT RESTORATION CAST IRON SLIP TYPE VALVE BOX. U 36 54 1/2 42 60 1/2 � o U W W U p t0 48 66 1/2 O NOTE: OPERATING NUT TO BE WITHIN 12" OF s V -_m ... 0 GROUND LEVEL WHEN COVER 2 WILKINS MODEL 975XL to a EXCEEDS 4'-0' TYP. ALL VALVES) WITH AN CU JACK &BORE DETAIL EXTENSION AND CENTERING DISK. WATER METER & POTABLE WATER REDUCED PRESSURE BACKFLOW ASSEMBLY C: Q � M.J. GATE VALVE, WITH RESTRAINED 0 � ♦"� O JOINTS ON EACH SIDE OF VALVE CROWN TRENCH ■ 3" MINIMUM MAIN PAINTED RED 1 EXISTING GRADE av r� -' =ke'. ,s'S"+*a`p'Y.`P�'' f r M �. g � T Y°s �. PUSH ON JOIN o .i3;�4 , x . _ UNDISTURBED EARTH �:�,,. �., ��.,-�_.n: � � r � CONCRETE VALVE PAD �„ r°�''"'c # ''' >• r $'�''vr a : r •.cis �aEx ;"S12 ra ,ya pAA .,��+i� �s�^��� WITH I.D. TAG + �x , e; `�t s� q VALVE BOX DETAIL SLIP TYPE FINAL GRADE PIPE RESTRAINT LENGTHS IN FEET } , METALLIC `3�s . � X"�;r '� a , ey �.�� �"',:' ?�• ���' 3 MARKING TAPE'�`z'` COMMON FITTINGS a my af���'1 .�,';o .` x' ' COMMON FILL 12" DEPTH �� 'e�t�; � r' xg"t)`?''t'�5},? 9i.,1 z 7 � � � f�"j• � � •��� TNT LENGTHS I N FEET M A T E R I A L S ITEM QUANT. DESCRIPTION 1 1 HYDRANT, FIRE 5 1 4" VALVE MIN. , PAINTED YELLOW 2 * 6" PIPE, P.V.C. DR-18 3 1 BOX, VALVE SLIP TYPE 4 1 6" VALVE, GATE, M.J. RESILIENT WEDGE 5 1 TEE, ANCHORING, M.J. 6 * 6" RESTRAINER GLAND (MEGALUG) 7 * VALVE EXTENSION ROD, AS NECESSARY (3' MAX. BE�GRADE) PIPE RESTRA R°k� TEES (BRANCH SIDE) +;y,.P" .1�°}..� ,�,•,,tm`*]i'$�',�•Y�l'sa G; 'S; ��`3q�"•�.i'�✓�y�'Y�'L r� gte�ti{y�Jsq,�� �c,C 'i-�la$:�i��.f't�'"T.;Cy,�i�4�.�a^ ���f ��� Ne•2k��J.'JSJ.:ki.�t,. r 4" MINIMUM — IOOSF SOIL OR SELECT MATERIAL I�Nx �I �I��y�'+I`��10�1��l�~�10�����j���t��lL � I�►gs�Ig�I�,I WATER MAINS — TEST PRESSURE 150 PSI BRANCH SIZE 3" 4" 6" 8" 10" 12" 16" 20" 24" 3" 6' 14' 30' — — — — — — 4" 2' 11' 28' 44' — — — — — N 6" 1' 2' 22' 40' 52' — — — — CO) 8" 1' 1' 16' 35' 48' 62' — — — 10" 1' 1' 10, 30' 44' 58' 83' — — 12" 1' 1' 3' 26 40' 66 80' 103' — 16" 1' 1' 1' 14' 31' 48' 75' 98' 119, 20" 1' 1' 1' 2' 27 40' 69' 94' 116' 24" 1' 1' 1' 1' 11' 31' 63' 89' 111' UNDISTURBED EARTH RESTRAINT LENGTHS ARE MEASURED FROM THE CENTER LINE OF THE TEE ALONG THE BRANCH FOR THE DISTANCE INDICATED. A MINIMUM OF 5 FEET OF NOTES: -LOOSE SOIL OR SELECT MATERIAL IS NATIVE SOIL EXCAVATED FROM THE RESTRAINED PIPE MUST BE INSTALLED ON BOTH RUNS TRENCH FREE OF ROCKS AND FOREIGN MATERIAL. OF THE TEE. MEGALUG TYPE RESTRAINERS ARE -COMMON FILL TO BE PLACED AND COMPACTED IN 12" LAYERS. REQUIRED ON ALL JOINTS. ROLLING EQUIPMENT SHALL NOT BE USED FOR COMPACTION UNTIL A MINIMUM OF 18" OF COMMON FILL HAS BEEN PLACED AND COMPACTED FIRE HYDRANT OVER THE PIPE. THREE FEET OF FILL SHALL BE PLACED BEFORE A HYDROHAMMER MAY BE USED FOR COMPACTION RESTRAINED JOINT TABLE WATER MAINS — TEST PRESSURE 150 PSI FITTING TYPE 11-1/40 22-1/20 450 900 DEAD END 4" 2' 4' 8' 20' 45' 6" 3' 6' 12' 28' 63' N 8" 4' 7' 15, 36' 82' N W 10" 4' 9' 18' 43' 98' o- 12" 5' 10' 21' 50' 116' n. 16" 6' 13' 26' 63' 148' 20" 7' 15, 31' 76' 179' 24" 9' 17' 36' 87' 208' FORCE MAINS — TEST PRESSURE 100 PSI FITTING TYPE 11-1/40 22-1/20 450 900 DEAD END 4" 1' 3' 6' 13' 30' 6" 2' 4' 8' 19, 42' N 8" 2' 5' 10, 24' 55' cf) W 10" 3' 6' 12' 29' 66' a 12" 3' 7' 14' 34' 77' a 16" 4' 8' 18' 42' 99' 20" 5' 10, 21' 50, 119, 24" 6' 11' 24' 1 58' 1 139' PERPENDICULAR TO THE MAIN TEES (BRANCH SIDE) RESTRAINT LENGTHS ARE MEASURED FROM THE CENTER LINE OF THE FITTING ALONG THE PIPE IN BOTH DIRECTIONS (EXCEPT DEAD ENDS). PIPE LAYING CONDITIONS STANDARD UNPAVED AREAS RESTRAINED JOINT TABLE COMMON FITTINGS - il E 6 7 Novennw' .20; b ., Drawn: YZY Checked: Scale: As Shown Dwg: Utility Details Job No: 1372-10 Sheet 20 Of 27 Sheets _ __-_1_1 _ I I ' I _ _ I I I I I I I 1 11 11 I 'l'Igrrtl I I I 1. A minimum cover of 36" shall be used on all water mains. Water Main 10' Min. Separation 2. A minimum vertical separation of 18" shall be required between crossing water mains and \11C sanitary sewer lines. Sanitary Sewer Line INLET SEWER 1. All water lines that are parallel to OUTLET M sanitary sewer lines shall be separated SEWER ao by a minimum clearance of 10 feet. i Sanitary Sewer Line 2. All water lines that are parallel to w 6' X 6' X 4' X 4' :� fl- STD. P.V.C. sanitary sewer lines and are separated DOUBLE Y BRANC C.I. CLEANOUT COVER STREET WITHOUT CURB + STREET WITH CURB, 3. When vertical separation of 18" is not possible the by a distance of less than 10 feet Shall U.S. FOUNDARY & MANUFACTURING CORP. SINGLE SERVICE DOUBLE SERVICE TRENCH sewer line shall be either cased in steel casing or be constructed according to either Option c. USF 7621 REVERSIBLE HANDHOLE RING AND FE RING TRENCH 1 MAIN SEWER WIDTH concrete the full length of the Pipe, so as not "A", "B", or "C" as described below. AND C.I. COVER I to allow a joint to be within 10 of the water main. FLOW 6' P.V.C.-s0• BEND CURB 8' X 6' , (SHORT RADIUS) , Option A - Construct water line a minmum P.V.C. WYE of 18" above the sewer and to R/W OR EASEMENT LINE STREET, ALLEY, EASEMENT, ?;;, , , - •. Water Main �� one side. Water line and Sewer R/W OR PROPERTY LINE shall be constructed of D.I.P. 4' MIN. HOUSE CONNECTION _" _ and the water and sewer joints --- ,.� -- --- LINE PLUG 4 SEAL 6' P.V.C. 45' BE 10' Min. 10' Min. shall be Staggered. - C1 -' (SHORT RADIUS) 6' P.V.C. BEND i _--- AS REQUIRED 76, P.V.C. -- N --- MARKER, PAINTED GREEN ' SERVICE 0Option B - Case the sewer lines in steel �; 8' X 6' P.V.C. WYE. LATERAL Less than casing. _—_—_ _ _—_ —_ (BRANCHES TO BE 18' Sanitary Sewer Line g LOCATED IN THE FIELD) CONCRETE SIDEWALK FINISHED GRADE Separation Option C - Case the sewer lines in concrete. 6" TRENCH WIDTH ALL ENDS TO BE P �--�{ 6„ PLUGGED & SEALED TRENCH W/STD. STOPPERS Case 2— Water Mains and Sewer Case 1— Water Main and Sanitary Sewer • a. WIDTH 6'P.V.C. OR PLUGS NOTE: ROAD SURFACE a^•a • SERVICE LATERAL r� OF MAIN SEWER HOUSE CONNECT ON lines crossing. lines parallel. STEEL TROWEL FINISH DROP MANHOLE TO BE USED WHEN THE `, . POTABLE WATER AND SANITARY SEWER CONFLICT DETAIL DIFFERENCE BETWEEN INVERTS IS 2' PLAN OR MORE. CURB DROP MANHOLE Al (BENCH AND INVERTS) RIGHT OF WAY VARIES L SIDEWALK 24' 8" PVC PIPE z x¢ CURB g GUTTER MIN. 2 Update per new site plan. 07/15/10 1 Per City comments. 05/08/08 No. Revisions Date MIN. 12 LONG T STREET ALLEY EASEMENT, TEMPORARY BLOW -OFF ASSEMBLY RED BRICK M R/w, ❑k PR❑PARTY LINE MIN. TO BE REMOVED AFTER TESTING PVC CLEAN -OUT AT R/W LINE OR EASEMENT LINE TOP OF INLET TREATED WOOD MARKER PAVEMEN I DEPTH 7'-0' 3 SEWER WYE BRANCH STAKE, 2' X 4' OR GREATER M O TO BE DETERMINED IN TR?TCH CONCRETE VALVE PAD6' P.V.C. 0 J THE FIELD. MIN. WWITH I.D. TAG SERVICE PIPE SERVICE LATERAL6' P.V.C. SERVICENL� THE (TYPJ 1% MIN. SLOPE LATERAL CONCRETE CRADLE LL�WORD (WATER) ON COVER 6' MIN. R/W LINE 0 DEPTH LESS STREET ❑ 1�1 __—THAN 7'-Y +� A TO BE DETERMINED IN FINAL GRADE p I OUTLET THE FIELD 60• MAX. 6' X 6' X 4' X 4' ST X Q MIN. SLOPE 1/8' PE MAX O U- a n ' to SEWER 4 P.V,C. DOUBLE 'Y' BRANCH O PLUG SEAL 8 SLOPE WHERE UNDISTURBED t FOOT. USE GREATER EART CONNECTION BY CUSTOMER E (TYPJ 4' MIN. •'`••',.v �'r,;;�`+'•� 6 � 1 �;�l,t "ti>������ � POSSIBLE STREET WITHOUT CURB STREET WITH CURB 2" cALv. COUPLING WITH -_ SINGLE SERVICE CONNECTION DOUBLE SERVICE CONNECTION rn BPLUG ELOW NGRADEUNDISTURBED MATERIAL ED 4" _._ ..._.__._- ", _.:. I Co _ Z C DEPTH LESS THAN 7'-0' DEPTH 7'-0' ❑R GREATER It c J pip C VALVE BOX (TOP SECTION) UJ VALVE BOX FLOW SANITARY SEWER MAIN (TYPE 'A') I (TYPE 'B') t• M C 4) C.I. SLIP TYPE ♦ _ C c n SECTION aC z I* uj d W c `O (D w o p`" NOTE: - CONTRACTOR SHALL MAKE, ON A CLEAN SET OF PLANS, THE FINAL STATIONING OR C to rL E DISTANCE AND DIRECTION FROM MANHOLE OF EACH SERVICE LATERAL AND THEN GIVE co TO ENGINEER FOR RECORD PURPOSES. CA FL 00 i0 0 - INLET PROVIDE 2' x 4' PRESSURE TREATED WOOD MARKER STAKE AT ALL SANITARY SERVICES d !s (INCLUDE IN PIPE PRICE), TOP OF STAKE TO BE PAINTED WITH GREEN PAINT. WATER MAIN SEWER A ' �i A THE MINIMUM DIAMETER OF ALL SERVICE LATERALS SHALL BE 6 INCHES. STEEL TROWEL FINISH SANITARY SEWER - SINGLE WYE CONNECTION SEWER LATERAL TAPPED PLUG GATE VALVE OR REDUCER AND TYPICAL CLEAN -OUT CONNECTION STANDARD MANHOLE NOTES: (BENCH AND INVERTS) - MECHANICAL JOINTS/UNDERGROUND PIPING SHALL BE RESTRAINED AS SPECIFIED IN JOINT RESTRAINT TABLE (DETAIL 46) - VALVE EXTENSION ROD SHALL BE UTILIZED, AS NECESSARY, SO THAT VALVE OPERATING R NUT IS A MAXIMUM 0F 3 BELOW GRADE. PERMANENT CU BLOW -OFF DETAIL '0 NOTE: NOTE: CONNECTION BY CUSTOMER CU a NOTE: ECCENTRIC CONES PRECAST CONCRETE PRECAST CONCRETE ARE ACCEPTABLE, SET SHALL ATTAIN A MINIMUM IN LINE WITH FLOW. SHALL ATTAIN A MINIMUM C COMPRESSIVE STRENGTH EXTERIOR COATING COMPRESSIVE STRENGTH CONCRETE WALK O 0 V u) OF 4,000 p.s.i. AT 28 DAYS. KOPPERS BITUMASTIC OF 4,000 p.s.i. AT 28 DAYS. PRECAST CONCRETE MARKER, PAINTED GREEN V O •CU p C.I. MANHOLE FRAME & COVER BLACK SOLUTION, C.I. MANHOLE FRAME & COVER SHALL ATTAIN A MINIMUM V �A' 2 COATS. DOUBLE WYE BRANCH 05 W USF NO. 170-E ORS OR EQUAL OR USF NO. 170-E ORS OR EQUAL COMPRESSIVE STRENGTH C.I. CLEANOUT COVER Q I W/ WORD "SANITARY", TYPE II PORTLAND I W/ WORD "SANITARY", H-20 LOAD RATED. CEMENT MUST BE 4. H-20 LOAD RATED. OF 4,000 p.s.i. AT 28 DAYS. CAP co 4. USED IN THE C.I. MANHOLE FRAME & COVER O I..L. 2" BELOW MANHOLE FINISHED GRADE 2" BELOW MANHOLE FINISHED GRADE USF NO. 170-E ORS OR EQUAL (TYP. ALL MANHOLES) MANUFACTURING (TYP. ALL MANHOLES) I W/ WORD "SANITARY", r , C PROCESS NOTE: CENTER RING & COVER H-20 LOAD RATED. f- TO SANITARY SEWER MAIN - �/ BRICK LEVELING COURSE BRICK LEVELING COURSE TYPE ALL MANHOLE MANHOLES) FINISHED GRADE I P PL r ( SERVICE PIPE 12" MAX. 12" WIDE 12" MAX. CD WRAPID SEAL 12' WIDE WRAPID SEAL R/W OR EASEMENT LINE (n Q PRECAST ° �— 2 IA. ALL PRECAST 2' IA• • JOINTS TO BE BRICK LEVELING COURSE— ALL(� AQ�' UNITS MFG. T UNITS MFG. IN SEALED W/ 0-RING 12" WIDE 8" MAX. / MARKER, PAINTED GREEN O ' V ACCORDANCE W/ ACCORDANCE W/ SEALS OR SINGLE A.S.T.M. SPEC. JOINTS TO BE OFFSET SEAL WRAPID SEAL d O C-478 , •' , • A.S.T.M. . SPEC. °: ° • SEALED W/ 0-RING (ASTM C-443) ALL PRECAST ° 22)IA..�a a ` SEALS OR SINGLE UNITS MFG. IN ° �^ OFFSET SEAL j ." ACCORDANCE W/ (ASTM C-443) y WRAPID SEAL A.S.T.M. SPEC. CONNECTION BY CUSTOMER U WRAPID SEAL 3" MIN- . ° C-478 F ' 6" WIDE 5' OR LESS NOTE: 6" WIDE I • EXTERIOR COATING, PLAN ECCENTRIC CONES KOPPERS BITUMASTIC _ ARE ACCEPTABLE, SET w — — w BLACK SOLUTION, GROUT R/W OR EASEMENT LINE IN LINE WITH FLOW. 5" MIN. J 2 COATS. C.I. CLEANOUT COVER T m ° Q OR U.S. FOUNDARY & MANUFACTURING CORP. TYPE II PORTLAND USF 7621 REVERSIBLE HANDHOLE RING AND FE RING MARKER, PAINTED GREEN C_ > =sue' ,,3: 5" MIN. > > CEMENT MUST BE AND C.I. COVER WRAPID SEAL • USED IN THE • WRAPID SEAL MANUFACTURING CONCRETE SIDEWALK 6„ FINISHED GRADE ° ° • • ° EXTERIOR COATING, 6" WIDE • i w ° ° ° • ° e ° ° ° ° ° ° • °e• ° a ' a ° ° + o • • 10" MIN. 6" KOPPERS BITUMASTIC 6" WIDE NOTE: ° • e e ° ° o e ° ° ° e BLACK SOLUTION, INLET T ROAD SURFACE \ 2 COATS. I� SEWER • '• w ECCENTRIC CONES i a T Of ARE ACCEPTABLE, SET a.. `e a o '• a Y '�.•� OR 4'-0' DIA. FLEXIBLE BOOT W/ 0— IN LINE WITH FLOW. /f57 WHITE STONE a F a c� TYPE II PORTLAND S.S. STRAP CLAMPS a_— 4'-O" DIA. c,'• FLEXIBLE BOOT W/ UNDISTURBED •% �'• CEMENT MUST BE ° SOIL +, USED IN THE (ASTM C-923) S.S. STRAP CLAMPS CURB � MANUFACTURING N (ASTM C-923) • NOTE: - A BEDDING OF CLASS I, CLASS II, OR CLASS III MATERIAL SHALL BE REQUIRED WHEN THE MANHOLE BOTTOM CANNOT z a ]VI 91 P POURED IN s • •• ._ BE INSTALLED ON UNDIST REED SO OR IF THE NATIVE SOIL 8" PVC PIPE L U IL '., . IS CLASS IV OR CLASS V MATERIAL. CIO $UP.�; ' PLACE CONC. MIN. 12" LONG M i Vas 3' CLEAR OR PRE -CAST 3" CLEAR - THIS TYPE OF CONSTRUCTION SHALL BE LIMITED TO DEPTHS Ll 04 • - + • . • . • • • • ° ° ° OF (0-5) FEET. PVC CLEAN -OUT AT R/W LINE OR EASEMENT LINE • ' • •r s EXTERIOR COATING SHALL BE KOPPERS BITUMASTIC BLACK SOLUTION, / RED BRICK GROUT FILLET SERVICE PIPE raiberele�, NO. 4 REBAR AT 12" O.C. NO. 4 REBAR AT 12" O.C. SLOPE GROUT ON EACH 2 COATS. 1% MIN. SLOPE DOUBLE WYE BRANCH Nov 4, 2010 REINFORCE PER EACH WAY GROUT FILLET EACH WAY SLOPE GROUT ON EACH SIDE OF FLOW CHANNELS - WRAPID SEAL MUST BE USED ON ALL JOINTS, CASTINGS AND RISER RINGS. Date A.S.T.M. C-478 SIDE OF FLOW CHANNELS PIPE & REINFORCE PER WRAPID SEAL MUST BE USED IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. ASTM C-478 NOTE: 1. WRAPID SEAL MUST BE USED ON ALL JOINTS, CASTINGS AND RISER RINGS: ON ALL JOINTS FITTINGS - PASCO COUNTY SHALL HAVE THE OPTION OF SPECIFYING THE TYPE OF INTERIOR LINING ON AIR RELEASES, MANHOLES, GREASE/WATER, OIL/WATER SEPARATORS, AND WETWELLS. NOTE: 1. WRAPID SEAL MUST BE USED ON ALL JOINTS, CASTINGS AND RISER RINGS: ON ALL JOINTS TO BE INSTALLED FOR EACH INDIVIDUAL MANHOLE. 2. WRAPID SEAL MUST BE USED IN ACCORDANCE WITH MANUFACTURES RECOMMENDATIONS. ON AIR RELEASES, MANHOLES, GREASE WATER, OIL WATER SEPARATORS, AND WETWELLS. / / - PASCO COUNTY SHALL HAVE THE OPTION OF REQUIRING A NEGATIVE PRESSURE TEST / 3. PASCO COUNTY SHALL HAVE THE OPTION OF SPECIFYING THE TYPE OF INTERIOR LINING 2. WRAPID SEAL MUST BE USED IN ACCORDANCE WITH MANUFACTURES RECOMMENDATIONS. PER ASTM C-1244 TO BE INSTALLED FOR EACH INDIVIDUAL MANHOLE. 3. PASCO COUNTY SHALL HAVE THE OPTION OF SPECIFYING THE TYPE OF INTERIOR LINING - LIFT HOLES MUST NOT PENETRATE THE WALLS \ 4. PASCO COUNTY SHALL HAVE THE OPTION OF REQUIRING A NEGATIVE PRESSURE TEST TO BE INSTALLED FOR EACH INDIVIDUAL MANHOLE. CONNECTION BY CUSTOMER PER ASTM C-1244 4. PASCO COUNTY SHALL HAVE THE OPTION OF REQUIRING A NEGATIVE PRESSURE TEST 5. LIFT HOLES MUST NOT PENETRATE THE WALLS PER ASTM C-1244 UNDISTURBED MATERIAL SANITARY SEWER MAIN ELEVATION 5. LIFT HOLES MUST NOT PENETRATE THE WALLS MANHOLE STANDARD MANHOLE DROP MANHOLE SHALLOW CONSTRUCTION SANITARY SEWER -DOUBLE WYE CONNECTION (CLOSED BOTTOM) AND TYPICAL CLEAN -OUT Drawn: YZY Checked: Scale: As Shown Dwg: Utility Details Job No: 1372-10 Sheet 21 Of 27 Sheets NORTH _ _._ _._ _ - - -- - - - - MaIITERY -RO-AD - - - - - - - - - - - -.._ -.._....__._......_....-..._..__......_.._..._......--._....-.___....._....._,.._._---------------------- ---------___----------5------' I I \ -- r r�r"rr�rr®rrr�rrrstr�rr�w�r"rr ��rrwr�rr i I I I I I I I I I I I I ® I I I I I I i I D3-1 C I I - Notes for Traffic Control Devices in Private Streets 1. All traffic control devices shall be installed in conformance with the Manual on Uniform Traffic Control Devices and the Florida Department of transportation standards. 2. Street name signs shall be 9-inch on all road classifications. All signs shall have 6-inch series B letters. All street name signs on private roads shall be standard D3 street name signs with the colors reversed. White backgound with green letters and border. At intersections with county or state maintained roads; the county or state maintained road shall be green backround with white letters and border. 3. Any traffic control device for a private roadway placed in a county or state Right -of -Way shall be installed on the appropriate breakway post assembly. Pedestrain Crosswalk (Typ.) OhY See Sheet 23 D3-1 for Fot t King Road Signage Rp� r'(J R1-1 5�0� V, 24" Stop Bar \ \ R4-7 \ 00 O Pedestrain Crosswalk ♦ '. `� Yellow Nine Button Markers (OM-1). 4" White (Typ.) 7 \ \ I 24" Stop Bar � ; J I 1 I ' I , I i R4-7 I I 1 I I I I 00000 � �I Yellow Nine Button Markers (OM-1). I R , f I I \ i I 4 12' x 50' striped area 4" white (Typ.) ME 0 .� Detectable Warning per FDOT Index #304 (Typ.) 2 Red Nine Button Markers (OM-1) fastened to chain link fence � 000 000 00000 00000 O O / r pod eehsl°Pe Ds-1 Drl�e e� See Sheet 23 Daughtery Road OP Signage sT R1-1 2 Red Nine Button fastened to chain li Dlnnomnn# of Cinn Tabulation of Quantities Item Quantity Description R1-1 3 Stop Sign R4-7 2 Keep Right OM-1 2 Yellow Object Marker OM-1 4 Red Object Marker Street Name 2 24" White 52 Ft. Stop Bar 6" White 183 Ft. Pedestrian Crosswalk 6" White 739 Ft. Fire Zone Marking Arrow 14 4" White 4460 Ft. Stalls 4 White 920 Ft. Channelizing line 6" White 117 Ft. Channelizing line 6" Blue 240 Ft. Channelizing line Disabled Parking Sign 11 ,ole .0� 0 j i / y � L i ,LLL L L 4 L V L L L L V yr L V L L L v L L L / v W V L W L L L y L L d• W tlr' X I v w v .v w w .V w L . . L L L . L .Y vI v L L L L L Y w L L L L L L L W L L L l� L -WST'LAND- W � W X � v X \ W v Jr N W w w \ �� w' W� w W V W W W Vr W W W w W .✓ W III`\ Y J+ .Y V W W Y W W •Y W W � L W L W .L .Y W W w •V w \ \ \ W W \ k\ M r 3 Re-aligend crossing- walk 8 added signs. 08/31110 2 Updated per new Site Plan. 07/15110 1 Per City comments. 05/08/OS No. Revisions DateCo a- 'D � O o v ts�, it E eQr; -a �qUe� 1 tl 4 Date Drawn: n22 a YZY Checked: Scale: 1 "=50' Dwg: TrafkSig geaad Maddng Plan Job No: 1372-10 Sheet Of 27 Sheets L- — — !I 0 M O C s N m E m 0 z T v v v 0 O a 0 a 0 0 m 0 U w 0 N a Jd rn N a. 0 N n M 0 N n n - Specifications for Design and Installation of Traffic Control Devices on County Roads 1. Purpose: These specifications have been developed to provide developers with a uniform system for installation of traffic control devices on the County road system. A uniform system provides for reduced maintenance costs and a high standard of visibility for drivers. All required traffic control devices shall be installed by the developer of the project. 2. Florida State Statue 316.0745: 2.1) Any and all traffic control devices installed on the County road system shall conform to Florida State Statute 316.0745, uniform signals and devices. 2.2) This statute requires that all devices conform to Florida Department of Transportation (FDOT) Specifications. The FDOT has adopted the Federal Manual on Uniform Traffic Control Devices as the standards to be used in the State of Florida. 3. Pavement Markings: 3.1) All pavement markings shall be thermoplastic or preformed tapes; raised pavement markers shall be class "B". 3.2) Pavement markings and raised pavement markers shall be installed on all roads classified other than residential with an ADT greater than 500 vehicles, or if other conditions exist that require pavement marking,s (see M.U.T.C.D. section 313-1). 4. Traffic Control Signs: 4.1) All sign blanks shall be of a type currently certified by the FDOT for use in the State of Florida. 4.2) All sign faces shall be High Intensity grade and of a type currently certified by the FDOT for use in the State of Florida. 4.3) All signs shall be no less that the standard size as specified by the Federal Manual on Uniform Traffic Control Devices. No minimum size signing shall be accepted. Larger signs shall be used when required by design speed, etc. 4.4) All street name signs on private roads shall be standard D3 street name signs with the colors reversed, white background with green letters and border. At intersections with County, State or City maintained roads; the county or state maintained road shall be green background with white letters and border. The City maintained road shall be green background with white letters and border unless the city has adopted other colors. Street name signs shall be 6" on local roads and 9" on collector and arterial roads. Six inch signs shall have 4" series C letters and 9" signs shall have 6" series B letters. Street name sign brackets for 6" signs 30" long or less, or 9" signs 24" long or less, shall have 5 inch blade or cross. All other street name signs'shall be mounted with a 12 inch blade or 8 inch cross. All street name sign brackets shall be supplied with bolts, set screws will not be accepted. 4.5) On roads to be maintained by Pasco County, all signs other than street names shall be date coded with a yellow reflective label affixed to the back of the sign. It will be punched to show month, day, and year of installation (See Sample Label). Alternate label designs providing the date code information may be used if a sample is submitted and approved by Pasco County prior to installation. Sample Label: Size 2" x 4" DI'norr�or�f r%f Cirimin 1 1MVVv 1 awl 1% V■ .V Case II 6 Changed 5' sidewalk 08/31/10 to 10' trail, re-aligend crossing -walk on East side of Fort King Road 5 Updated per new Site 07/15/10 Plan. 4 Update per Pasco 10/09/08 County comments. 3 Update per Pasco 09/24/08 County comments. 2 Added Tabulation of 08/22/08 quantities table. 1 Per City comments. 05/08/08 No. Revisions Date WARNING' REMOVAL OF, OR DEFACING ANY TRAFFIC CONTROL DEVICE o' 00 IS PUNISHABLE BY FINE AND/OR IMPRISONMENT Pavement REPORT DAMAGE BY CALLING (727) 847-2411 Top of Ground Cover co INSTALLED Y y C O J F M A M J J A S O N D Tabulation of QuantitiesLL ,( N I- N 10's 20's 30's 1 2 3 4 5 6 7 8 9 a o - 01 02 03 04 05 06 07 08 09 Item Quantity Description 4.6) All post systems, mounting brackets, and hardware shall be of a type currently in use by the Pasco County Public Worsk Department and currently certified by the Florida Department of Transportation for use in Street Name Sign 4 9 inches o X Q u_ o the State of Florida. Altemative systems etc. shall only be used if approved by the County Engineer. Stop Sign 2 24" x24" goo m 6" white 1454 Ft. Channelizing Line The intent of This Standard is to provided A Window with Vertical � E 5. Certification of materials: 8" white 241 Ft. Channelizing Line Limits of not less than V above and 1'-6" below the sight line datum, ti o,q� 5.1) All traffic control devices and materials shall be on the current F. D. O. T. APPROVED PRODUCTS LIST. Proof of certification is required for all traffic control devices. 6" Double Yellow 2237 Ft. Channelizing Line and horizontal limits defined by the limits of clear sight. c s Z C) 5.2) A Traffic Control Devices Submittal Data Form shall be submitted for approval prior to installation of any traffic control devices. No traffic control device 6" White Skip (6-10') 72 Ft. Channelizing Line Z V.-. shall be installed until the certification submittal has been approved by the Traffic Operations Division. These forms are available from the Traffic 6" Yellow Skip (6-10') 126 Ft. Channelizing Line �■ -~+ r CIO r c co Operations Division. Copies of the approved Traffic Control Devices Submittal Data Form shall be sent to the contractor and the Engineering Inspection Division. 18" White 145 Ft. Chevrons C + 2 " m rn 24" White 36 Ft. Stop Bar Z L- j a a o 6. Traffic Control Devices Plan: 12" White 143 Ft. Crosswalk Note: `■ c cc 6.1) A detailed set of plans for required traffic control devices shall be submitted for all road construction site development, subdivision, and Right -of -Way Use Arrow 10 Site triangles are to a da cL -2 E 0 Permits. These plans shall be in conformance with FDOT design standards. All plans shall be signed and sealed b a registered professional engineer in the State of Florida. p g p g y e9 p g unobstructed and are to t y aco � m° 6.2) With the submittal of final plans to the Development Review Division, two additional sets of traffic control plan portion of the entire plan shall be submitted. These two sets will be forwarded to the Traffic Operations Division. Pictorial remain unobstructed. i 7. Cost Estimate: An engineer's cost estimate shall be required for all proposed traffic control devices. The estimate shall be provided in conjuction with the Traffic Control Devices Submittal Data Form (see Section 5.2). Window Detail 8. Inspection and acceptance: 8.1) Upon completion of the installation of the traffic control devices, the contractor shall call the Engineering Inspections Division for an inspection at (727) 847-8154. 8.2) The inspection shall be made by the Engineering Inspections Division 48 hours (two working days) of the request. 8.3) An inspection report shall be made by the Engineering Inspection Division. Copies of the report shall be sent to the Engineer and Developer. 8.4) No roadway shall be open to the Public until all traffic control devices have been inspected and accepted by Pasco County. i t' I �� II 415' II II ram 415' - - - �.a � b-m mm> - me gym, xKaax»«�ssx � a� - �a a..ex .4r �m � �'m � ,� � � ... ,m .�-. �+ mm•, �. �. ra» acm . a asa :� : tom. ��x.._ - 530' 530' Sight Distance at Fort King Road ' &kl,fiffiKfi..�u&" �e.i � •.....G.�.a2d'�Y+'»�Ea., �� -f,s5 awn �y. w.re .u.. Ms�s :.mow ix.++,d,.v,. «3e'u: �aauumpu'are :vatl. +L»a '�'R�aFa Sep, M� CU CO O LL � w O a: CL ViIA O o v C.)U t` NCU O .0 Uce� CO Cl)a) C s N co L.L O O U evil do's "A6 quer NovemWt 20°10 Date Drawn: YZY Checked: Scale: 1 "=60' Dwg: TmfkArlage and Mirk Plan Job No: 1372-10 Sheet 24 Of 27 Sheets 3 v