GENERAL NOTES SYMBOLS 8 IDENTIFICATION LEGEND FLORIDA 5UILDING GODS DATA I. ALL WORK SHALL CONFORM WITH THE LATEST ADOPTED EDITIONS OF THE FLORIDA BUILDING CODE, BUILDING (FBC-5) SEVENTH EDITION (2020), FLORIDA BUILDING CODE, PLUMBING (FBC-P) SEVENTH EDITION (2020), FLORIDA BUILDING CODE, MECHANICAL (FBC-M) SEVENTH EDITION (2020), FLORIDA BUILDING CODE, FUEL GAS (FBC-FG) SEVENTH EDITION (2020), FLORIDA FIRE PREVENTION CODE (FFPC) SEVENTH EDITION (2020), NATIONAL ELECTRICAL CODE (NEC) 2011 EDITION, NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) I - FIRE CODE (2018), NFPA 101 - LIFE SAFETY CODE 2010, FLORIDA ACCESSIBILITY CODE SEVENTH EDITION (2020) 4 ALL OTHER APPLICABLE LOCAL, STATE, 4 FEDERAL CODES 4 ORDINANCES 4 ALL AUTHORITIES HAVING LOCAL JURISDICTION. 2. THESE CONSTRUCTION DOCUMENTS HAVE BEEN PREPARED FROM THE MOST COMPLETE INFORMATION AVAILABLE TO THE ARCHITECT. ALL DATA ON EXISTING CONSTRUCTION CONDITIONS ARE APPROXIMATE 4 SHALL BE VERIFIED PRIOR TO COMMENCING ANY WORK. 3. IT SHALL BE THE SUBCONTRACTOR'S RESPONSIBILITY TO PERSONALLY FIELD INSPECT THE JOB SITE PRIOR TO SUBMITTING HIS BID. THE INSPECTION IS REQUIRED SO THAT THE CONTRACTOR SHALL BE TOTALLY FAMILIAR W/ THE EXISTING CONDITIONS 4 THEIR INTERFACE W/ THE NEW CONSTRUCTION AS DEFINED IN THESE CONSTRUCTION DOCUMENTS. 4. THE SUBCONTRACTOR SHALL PERFORM ALL WORK IN ACCORDANCE W/ THE LATEST EDITION OF THE GENERAL CONDITIONS OF THE CONTRACT, AIA DOCUMENT A201. A COPY OF THIS DOCUMENT IS AVAILABLE * THE CONTRACTORS OFFICE UPON REQUEST. 5. ANY ADJUSTMENT TO THE CONSTRUCTION CONTRACT, ADDITIONS, DELETIONS OR CHANGE ORDERS, SHALL BE APPROVED BY THE OWNER, GENERAL CONTRACTOR, 4 ARCHITECT IN WRITING. 6. DURING THE CONSTRUCTION PHASE, THE ADMINISTRATION OF THE CONSTRUCTION CONTRACT SHALL BE PERFORMED BY THE MCDONALDS CONSTRUCTION MANAGER -1. ALL WORK (EQUIPMENT, MATERIALS, 4 LABOR) SHALL HAVE A MINIMUM WRITTEN GUARANTEE FOR A PERIOD OF ONE (1) YEAR, UNLESS SPECIFIED OTHERWISE, FROM THE DATE OF SUBSTANTIAL COMPLETION AGAINST ANY DEFECTS IN SAID WORK, W/ APPROPRIATE REPAIR OR REPLACEMENT * NO ADDITIONAL COST TO THE OWNER S. ALL MATERIALS 4 EQUIPMENT SHALL BE INSTALLED IN A NEAT 4 FIRST CLASS WORKMANLIKE MANNER THE ARCHITECT RESERVES THE RIGHT t0 DIRECT THE REMOVAL 4 REPLACEMENT OF ANY ITEM, IN HIS OPINION, THAT DOES NOT PRESENT AN ORDERLY 4 REASONABLY NEAT OR WORKMANLIKE APPEARANCE. THE REMOVAL 4 REPLACEMENT SHALL BE DONE WHEN DIRECTED BY THE GENERAL CONTRACTOR, 4 W/OUT ADDITIONAL COST TO THE OWNER S. THE CONTRACTOR SHALL COMPLY W/ THE MANUFACTURER'S INSTRUCTIONS 4 RECOMMENDATIONS TO THE EXTENT PRINTED INFORMATION IS MORE DETAILED OR STRINGENT THAN REQUIREMENTS CONTAINED DIRECTLY IN THE PLANS. 10. CONTRACTOR SHALL MAINTAIN ORDERLY HOUSEKEEPING DURING THE PROCESS OF CONSTRUCTION 4 UPON COMPLETION SHALL THROUGHLY CLEAN ALL AREAS. FINAL CLEAN UP SHALL INCLUDE THE FOLLOWING: A. SWEEPING FLOORING. B. DUSTING 4 REMOVAL OF DIRT, PAINT DRIPPINGS, OIL, GREASE, 4 OTHER BLEMISHES FROM ALL SURFACES, INCLUDING PIPING 4 EQUIPMENT. C. WINDOWS, GLASS LIGHTS, 4 MIRRORS SHALL BE WASHED 4 CLEANED. D. PAINT OVERRUNS 4 PUTTY SMEARS SHALL BE REMOVED. E. HARDWARE SHALL BE CLEANED 4 POLISHED W/ FLANNEL CLOTH. II. WORK t0 BE DONE CONSISTS OF FURNISHING ALL MATERIALS, LABOR, EQUIPMENT, TOOLS, 4 ALL ITEMS 4 SERVICES REQUIRED FOR CONSTRUCTION IN CONFORMITY W/ GENERAL NOTES 4 PLANS. 12. THE PLANS SHOW THE LOCATION OF ALL FIXTURES 4 EQUIPMENT 4 ARE INTENDED t0 CONVEY THE GENERAL INTENT OF THE WORK IN SCOPE 4 LAYOUT. THEY ARE NOT INTENDED t0 SHOW IN MINUTE DETAIL EVERY 4 ALL OF THE ACCESSORIES INTENDED FOR THE PURPOSE OF EXECUTION OF THE WORK, BUT IT IS UNDERSTOOD THAT SUCH DETAILS ARE PART OF THIS WORW, 13. THE SUBCONTRACTORS SHALL REMOVE ALL CONSTRUCTION RUBBISH, SCAFFOLDING, EQUIPMENT, TEMPORARY PROTECTION, TEMPORARY FIELD STRUCTURES, 4 OTHER COMPONENTS WHICH WERE REQUIRED IN CONNECTION W/ THE CONSTRUCTION, BUT NOT A PERMANENT PART THEREOF. 14. THE CONTRACTOR SHALL OBTAIN ALL NECESSARY PERMITS 4 INSPECTIONS REQUIRED FOR THE WORK 4 PAY ALL CHARGES INCIDENTAL THERETO. 15. PROVIDE DOOR HARDWARE IN CONFORMANCE W/ ADA REQUIREMENTS. 16. THE SUBCONTRACTOR SHALL FURNISH ALL MISCELLANEOUS FACILITIES AS NEEDED, INCLUDING TEMPORARY STAIRS, TEMPORARY RAMPS, LADDERS, RUNWAYS, STAGING, SHORING, SCAFFOLDING, BRIDGES, RAILING, BRACING, BARRIERS, CLOSURES, PLATFORMS, TEMPORARY PARTITIONS, WASTE CHUTES, 4 SIMILAR ITEMS. THE SUBCONTRACTOR SHALL PROTECT ALL CONSTRUCTION COMPONENTS DURING THE COURSE OF PAINTING 4 SHALL PROMPTLY CLEAN ALL RESIDUE, SPLATTER OR OVERSPRAY UPON COMPLETION OF HIS WORW, THE CONTRACTOR SHALL USE DROP CLOTHS, MASKING, 4 OTHER SHIELDING DEVICES t0 THE GREATEST EXTENT PRACTICAL TO PROTECT ALL ITEMS NOT TO BE PAINTED OR THOSE ITEMS WHICH HAVE ALREADY RECIEVED FINAL FINISH COATS. 18. ALL PAINTING REQUIRED FOR THIS PROJECT SHALL BE PERFORMED IN ACCORDANCE W/ THE MANUFACTURER'S SPECS FOR PRODUCT HANDLING, SURFACE PREPARATION, PAINTING APPLICATION, CURING/DRYING TIME BETWEEN COATS, CLEANING 4 PROTECTION OF PAINTED SURFACES UNTIL THE SOURCE OF CONSTRUCTION IS COMPLETE. PAINT COLORS t0 BE SELECTED FOR THESE DOCUMENTS ARE AS MANUFACTURERD BY BY GLIDDEN DIVISION OF SCM CORP., ALTERNATE ACCEPTABLE MFR ARE AS FOLLOWS: BENJAMIN MOORE, D.P.I., RUSTOLEUM, PRATT LAMBERT, SHERWIN- WILL IAMS. 19, ALL DRYWALL PARTITIONS ARE DIMENSIONED CENTERLINE TO CENTERLINE UNLESS OTHERWISE NOTED. ALL MASONRY PARTITIONS ARE DIMENSIONED OUT TO OUT. 20. ELECTRICAL PANELS, FIRE EXTINGUISHER CABINETS, ETC., LOCATED IN RATED PARTITIONS SHALL BE BACKED W/ DRYWALL AS REQUIRED TO MAINTAIN RATING. CONTRACTOR t0 VERIFY WALL THICKNESSES REQUIRED FOR ALL ELECTRICAL PANELS, FIRE EXTINGUISHER PANELS, ETC. 21. PROVIDE DOUBLE STUDS 4 BLOCKING WHERE REQUIRED TO SUPPORT MISCELLANEOUS ITEMS, I.E. TYPICAL CASEWORK, CABINETS, GRAB BARS, ETC. CONTRACTOR SHALL FURNISH 4 INSTALL ALL BACK-UP SUPPORTS 22. DO NOT SCALE DRAWINGS. IF DIMENSIONS ARE IN QUESTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING CLARIFICATION FROM THE OWNER'S REPRESENATIVE BEFORE CONTINUING W/ CONST. 23. CONTRACTOR SHALL VERIFY ALL DIMENSIONS 4 COORDINATE ALL TRADES. 24. CONTRACTOR SHALL VERIFY ALL EQUIPMENT LOCATIONS 4 DIMENSIONS OF EQUIPMENT. 25, REVIEW ALL ELECTRICAL LOCATIONS W/ OWNER BEFORE SIGN OFF FOR DRYWALL. 26, ALL THRESHOLDS 4 FLOOR FINISH CHANGES TO BE PLACED UNDER CENTERLINE OF DOOR UNLESS OTHERWISE NOTED. 21. COORDINATE TELEPHONE 4 SECURITY W/ OWNER BEFORE PROCEEDING. 28. ROOF CONSTRUCTION IS NOT LIGHT FRAME TRUSS 29. A SEPARATE PERMIT SHALL BE REQUIRED FOR THE FIRE SUPPRESSION SYSTEM 30. ALL INSULATION MATERIALS TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 25 AND A SMOKE -DEVELOPED INDEX OF NOT MORE THAN 450 PER THE FBC 7192 31. CONCRETE FLOOR SLAB REPLACEMENT SHALL BE 5" CONC. SLAB W/ 6X6-W1.4XW1.4 WWF ON 6 MIL VAPOR BARRIER OVER 12" MIN. CLEAN COMPACTED FILL W/ TERMITE TREATMENT. TIE NEW SLAB INTO EXISTING SLAB/STRUCTURE W/ 03 • 2'-0". EPDXY W/ MIN. 6" EMBED. ROOM IDENTIFICATION DRAWING IDENTIFICATION INTERIOR/CASEWORK ELEVATION IDENTIFICATION SECTION CUT INDICATION PLAN OR SECTION DETAIL INDICATION ROOM NAME FLOOR / LEVEL 201 ROOM NUMBER 2 DRAWING NUMBER SHEET NUMBER DRAWING NUMBER 2-A4 INDICATION OF DIRECTION SHEET NUMBER 3 DRAWING NUMBER INDICATION OF DIRECTION ,4ro SHEET NUMBER 00, 3 \ DRAWING NUMBER DETAILED AREA ,44 \ j SHEET NUMBER SUPPLEMENTARY DRAWING INDICATION (BOUND IN PROJECT MANUAL). Ste' ELEVATION, SECTION CUT, 4 PLAN DETAIL NOTATIONS SIMILAR TO ABOVE 22 DOOR IDENTIFICATION 22 WINDOW/GLAZING IDENTIFICATION O SPECIFIC NOTES O GENERAL NOTES jam, FURNITURE 4/OR EQUIPMENT 101 IDENTIFICATION ELEVATION SYMBOL REVISION SYMBOL PARTITION TAG DRAWING NUMBER PAGE NUMBER SEE SCHEDULE SEE SCHEDULE NOTES WHICH APPLY TO SPECIFIC ITEM OR ITEMS ON THE DRWG WHERE INDICATED NOTES WHICH APPLY TO ALL DRAWINGS SEE SCHEDULE FIN FLOOR ELEVATION HEIGHT ELEV 100'-0" SURFACE DESCRIPTION Ql REVISION NUMBER DATE REVISED AI DRAWING NUMBER MATERIAL DE&IGNATIONS ELEVATION /FLAN SECTION ®CERAMIC ® GLAZING TILE/ QUARRY TILE ®MASONRY RUNNING ® CONCRETE BLOCK BOND CONCRETE/ STUCCO/ GROUT III-_ I EARTH ROCK ®WONT WOOD BLOCKING an,W, • • . CLASSIFICATION BY OCCUPANCY ASSEMBLY GROUP A-2 MIXED OCCUPANCY NO SEPARATION BY OCCUPANCY NONE TYPE OF CONSTRUCTION PROTECTED - HR UNPROTECTED V SPRINKLERED ❑ YES NO BUILDING VARIABLES REQUIRED 4 ALLOWED PROVIDED BUILDING HEIGHT 4 HEIGHT INCREASES 40' 1i'-211 NUMBER OF STORIES 1 1 BUILDING AREA / 3,9"19 GSFt + FLOOR AREA INCREASES (o,000 GSF 3511 GSF FREEZER/COOL OCCUPANT LOAD / FLOOR AREA / PERSON " OF FIXED SEATS 80 ERSONS ASSEMBLY TOTAL SEATING / PERSON N/A N/A EGRESS WIDTH / PERSON 1ST FLR 2 / 16" 108" LENGTH OF DEAD END 20' 0' MAXIMUM DISTANCE TO AN EXIT 200' S0' MINIMUM NUMBER OF EXITS 2 2 FIRE PROTECTION REQUIREMENTS STRUCTURAL FRAME - INCLUDING 0 0 COLUMNS, GIRDERS, TRUSSES BEARING WALLS - EXTERIOR 0 0 INTERIOR 0 0 NONBEARING WALLS AND PARTITIONS - EXTERIOR 2t30 0 0 NONBEARING WALLS AND PARTITIONS - INTERIOR 0 0 FLOOR CONSTRUCTION - INCLUDING SUPPORTING BEAMS 4 JOINTS 0 0 ROOF CONSTRUCTION - INCLUDING SUPPORTING BEAMS 4 JOINTS 0 0 FLORIDA PLUM51NG CODE DATA OCCUPANCY RESTAURANTS REQUIRED 4 ALLOWED FIXTURES MALE/FEMALE WATER CLOSETS 4 URINALS LAVATORIES 2 DRINKING FOUNTAINS i!i!i!i!i!i! _ ' r IIIIIIIIIIIII El PII I Wt% d rol. CUT STONE ®METAL (LARGE SCALE) ARCHITECTURAL ABBREVIATIONS EXTERIOR INSULATION J A^ v n^n� TERRAZZO PROVIDED MALE/FEMALE 3 I 4 Illilllillllllllll - r•; ''�"•� LIGHTWEIGHT '.,�.'�' •�• •�• GYPSUM BD./ CONCRETE PLASTER/ STUCCO a :g STRUCTURAL WOOD CONCRETE BLOCKING INDEX OF DRAWING5 ARCHITECTURAL CS COVER SHEET ARI AR SHEET DI DEMOLITION PLAN AND NOTES AID FLOOR PLAN ND NOTES ALL / 1 AI.2 PROPOSED SEATING PLAN A13 I T P ANS, ELEVATIONS, AND DETAILS AIA N/A A2.0 ELEVATIONS A2.1 ELEVATIONS ELECTRICAL E1.0 ELECTRICAL LIGHTING PLAN 4 SCHEDULE E2.0 ELECTRICAL POWER PLAN E3.0 ELECTRICAL SCHEDULE E4.0 ELECTRICAL DETAILS KITCHEN EaUIf=1"*lENT. KID KITCHEN COVER K2.0 EQUIPMENT PLAN K3.0 EQUIPMENT SCHEDULE ALL WORK SHALL COMPLY WITH PREVAILING CODES FLORIDA BUILDING CODE. NATIONAL ELECTRIC CODE, AND THE CITY OF ZEPHYRHILLS ORDINANCES REVIEW DATE: t- r2Z- CITY OF ZEPHYRHILLS BUILDING OFFICIAL AFF ABOVE FINISHED FLOOR CI CAST IRON DN DOWN FT FEET HC HANDICAPPED MECH MECHANICAL OD OUTSIDE DIAMETER SCH SCHEDULE TH THRESHOLD ADJ ADJUSTABLE CB CATCH BASIN DWG DRAWING FND FEMININE NAPKIN DISPOSAL HWD HARDWARE MT METAL SNT SEALANT TKBD TACKBOARD AC AIR CONDITIONER CLG CEILING OF DRINKING FOUNTAIN FNV FEMININE NAPKIN VENDOR HT HEIGHT MF METAL FRAME PBML PAPER -BACKED METAL LATH SHT SHEET TPH TOILET PAPER HOLDER ALT ALTERNATE CEM CEMENT FIN FINISH HRIZ HORIZONTAL MRO METAL ROOF DECK PTD PAPER TOWEL DISPENSER SHO SHOWER T 4 G TONGUE 4 GROOVE ALUM ALUMINUM C, CENTERLINE EA EACH FE FIRE EXTINGUISHER MIN MINIMUM PTH PAPER TOWEL HOLDER SHOO SHOWER CONTROLS TB TOWEL BAR AB ANCHOR BOLT CHBD CHALKBOARD E EAST FECR FIRE EXTINGUISHER INCL INCLUDE M MIRROR PLAS PLASTER SHOW SHOWER HEAD TYP TYPICAL UNLESS 4 AND CLO CLOSET ELEC ELECTRICAL CABINET RECESSED ID INSIDE DIAMETER MISC MISCELLANEOUS PLYWD PLYWOOD SIM SIMILAR OTHERWISE NOTED L ANGLE CH COAT HOOK END ELECTRIC HAND DRYER FH FIRE HYDRANT MR MOISTURE RESISTANT PT PRESSURE TREATED SD SOAP DISPENSER U URINAL APPROX APPROXIMATELY COL COLUMN EWC ELECTRIC WATER COOLER FL FLOOR JT JOINT M514 MOP 4 BROOM HOLDER SH SOAP HOLDER At CONC CONCRETE ELEV ELEVATION FD FLOOR DRAIN MTO MOUNTED R RADIUS S SOUTH VERT VERTICAL CONST CONSTRUCTION ENCL ENCLOSED / ENCLOSURE FTG FOOTING LAM LAMINATE RPtD RECESSED PAPER SPECS SPECIFICATIONS CONT CONTINUOUS EQ EQUAL FM FRAMED MIRROR LAV LAVATORY N NORTH TOWEL DISPENSER SQ SQUARE WR WASTE RECEPTICAL BD BOARD CONTR CONTRACTOR EQUIP EQUIPMENT NIC NOT IN CONTRACT RECT RECTANGULAR SS STAINLESS STEEL WC WATER CLOSET BM BEAM CJ CONTROL JOINT EXIST EXISTING GALV GALVANIZED MH MAN HOLE NITS NOT TO SALE REINF REINFORCEMENT STD STANDARD WH WATER HEATER BLK BLOCK EJ EXPANSION JOINT GA GAUGE MFR MANFACTURER NO NUMBER REQD REQUIRED STL STEEL W WEST BRK BRICK DTL DETAIL EXP EXPOSED GB GRAB BAR MO MASONRY OPENING RD ROOF DRAIN STIR STRUCTURAL W/ WITH Q �ld"G u D�N� �A11 1NET /0 GWB GYPSUM WALLBOARD IR RM _ SMS STRUCTURAL METAL W/O WITHOUT CPT CARPET DIIM DIIMENSION EGCB EXTERIOR GYPSUM GYP GYPSUM MAX MAXIMUM OPNG OPENING RO ROUGH OPENING DR DOOR CEILING BOARD y z 0 a 0 Li 0 z 0 Ln 0 U w 0 w w N t2 o 0 V 'may o • g a L M" .. a U 0 3 a + U • . „� 4� • • ¢e -' 00 w L -C M U. . �$ • p� a •zM U coi � 'Jpa�i tz .. Q 'c aa° w� U� o qx>tcu=) i-o ` o aoa�v° Sao cc ° oEg�c o N w o o .� 3 ;- to Q a a o o n U cci o 4v.c1.o N n ] - ,O C 2 O « y U° C° a c: O "_ °o L coa+0 N p U O poC O U y°c °c� �voo'mEIn ° C U C ° N O °-- co° N U CQ.. N •� c U� Lin O J C O p O N O .V Q C - V 'O 8 «Np•w°cio O U� arc N ° U C N U N a_rn .` w p t U C O N a) O � c � aV ° o � 0 C) w o U ::.T -C) ao °? -a - O p 3 p p° ® °� Qy a 0 > O N U U r ° `oa'Za' !- a3�c-ai_ a m p m � N N 3 j w tn N In T v o 0 0 C M 0 0 N m O f2 c� Qz N 0 o 1 0c � U L U W t13 o o N Ar- c) co W � qo - o J QQC N C w C� G D U N O 1802.31 z w AR 1 V) AA-0003276 IImi I - ____ _. Im 7 GENERAL NOTES: L ALL EXIT DOORS SHALL BE KEYLESS IN THE DIRECTION OF EGRESS. 2. THE OPENING FORCE OF ALL EXT. PUSH/PULL DOORS SHALL NOT EXCEED 8 IR LOS. 3. THE OPENING FORCE OF ALL INTERIOR PUSH/PULL DOORS SHALL NOT EXCEED 5 LBO. 4. PROVIDE PANIC HARDWARE FOR ALL EXTERIOR DOORS AS NOTED ON THE DOOR SCHEDULE. S. ALL DOOR I4ARDWA1W SHALL NOT REaJIRE TIGHT GRASPING, TIGHT PINCHING OR TWISTING OF THE WRIST TO OPERATE. DOOR h 1. 1 EA CLOSER LCN 4021 x 18 2. 3 EA HINGES OFFSET PIVOT ANSI -A-36A GRADE It PROVIDE EXPOSED PARTS OF CAST ALUMINUM ALLOY, AS SUPPLIED BY DOOR MANUFACTURER 3. 1 EA PUSH/PULL HANDLE KALtiNEER'CO-9 OR HAGER PUS MOULL SET 1640N/B. 4. N/A 5. 1 EA THRESHOLD NATIONAL. GUARD PRODUCTS, INC. SADDLE TYPE THRESHOLD 325, LU 36" WIDE x 10" RISE (ADA ACCESSIBLE). l 6, 1 EA WEAT14ER STRIPPING: PROVIDE COMPRESSION WEATHER STRIPPING AGAINST FIXED STOPS. AT OTHER EDGES PROVIDE SLIDING WEATHER STRIPPING RETAINED IN ADJUSTABLE STRIP MORTISED INTO DOOR EDGE. PROVIDE EPOM OR VINYL GASKET WEATHER STRIPPING IN BOTTOM DOOR RAIL ADJUSTABLE FOR CONTACT W/ THRESHOLD. I. I EA SIGN MOUNT ONTO DOOR TO READ "THIS DOOR MUST REMAIN UNLOCKED WHENEVER THE BUILDING IS OCCUPIED/DURING BUSINESS HOURS." 1�- DOOR w I. I EA HINGE 180-112HD 83" ALUM HAGER S. 1 EA TREADPLATE 24 X 34 UMCO 2. 1 EA CLOSER 1461 RW/PA ALUM LCN S. 1 EA VIEW FRAME LFRA100 6 X 21 3. 1 EA LOCK NDSOPD RHO 626 SCHLAGE DKB N,GUARD 4. 1 EA ELEC STRIKE 6211 24V DC FOE U6320 SCHLAGE 10.1 EA GLASS 5 X 26 X 1/4 UMCO 5. 1 EA PWR SUPPLY P8902 SCHLAGE IL I EA GLASS 5 X 26 X 1/4 UMCO O6. 1 EA DOOR BELL 06V-24P SURFACE MOUNTED 1. 3 EA PUSH BUTTON 621-RD-DA HDP 626 SCHLAGE 000 ------------- I I I I I I I 1 I � O I ° I I I 0 0 6 I I I I I ------------- o I I I ---------� D I I I I 1 A13 ® TL - IG - DF 61"A.F. 0 I I I I I I I I I M I I I I I I I 19,'-1 1/2" VERIFY RH 3 L CC TO INSTALL ACCESSIBILITY DOOR 81&* WHERE REQV BY LOCAL CODES 2. DETEX ALARM CONTACT SWITCHES SHALL BE RECESSED INTO THE TOP OF THE DOOR t HOLLOW METAL FRAME ADOVE. FRAMES, 1 3. DOORS, DOOR 14ARDWARE FOR DOORS 3, 3A 5, 6, 6A,1, SUPPLIED 5Y: UNIVERSAL MANUFACTURING I-SM-821-1414. 4. NOT USED 1 1 is. SEE ELEVATIONS AND WALL SECTIONS 6. ALL INTERIOR SOLID CORE WOOD DOORS TO HAVE A LAMINATED FINISH, AS INDICATED PER DECOR DWGB 1. NOT USED v & ALL EXTERIOR DOOM aRkL HAVE MAX W" LEAL C"4E PER MC IvtL6 MARK DOOR FRAME MATERIAL SIZE TYPE MATL SIZE n/ !� I ALUM. 3'-0"x1'-0"xl 3/4" A ALUM. (NOTE 6) O 10 H.M. 3'-0"04"A 3/4" C HM. 20JAMB 411HD Q w -ANODALUM. DOOR _ 1/4" TEMP. n/ GLAZING - Q 1011 STILE AT BOTTOM C 0 3 NOTES O I I I I I I I I I I I I I I I I ! II r! 0 I I 6' -1 3/4" TILE TILE cA 13 0 1 A 4LF J �� - i - I1 C 10 A 5 F�- A� 6 AI3 12 13 14 AI3 6 A13 1 0 0 0 0 0 0 / \ 00 00 00 NOTE: GENERAL CONTRACTOR SHALL VERIFY ALL SEATING AND DINING DIMENSIONS BEFORE PROCEEDING WITH DECOR INSTALLATION. NOTE: GENERAL CONTRACTOR SHALL INSTALL A POLYETHYLENE BARRIER IN AREAS OF REMODEL WORK THAT REQUIRE DUST PROTECTION. MEANS AND METHODS OF INSTALLING THIS POLYETHYLENE BARRIER SHALL BE PER THE GENERAL CONTRACTOR BASED ON EXISTING FIELD CONDITIONS. Z O a U cn w 0 Z 0 0) 0 L) d w W M N N2 Q 0 0 I I E �' • I • ch T I i 0m 4 15 i I a, I 1 0.�3 5'-0" I --4'-8 I/2" --40 •� F� w J L xM ----------- g a�U oQ 13 1 • z M 0- am I I 6 �.----------- J �-Co �N 3-0 °°J N U0-04) �: v0 >on oao L- v a O +O O Nfir w y u vj m U+C NU+ I N N _ c °°;o°ya 1 4 V C-0 O C O --� ° Q _. c , 0-0:5 crop°o°c p C U C r X _t+ ° J w Do o N O m ° C N '0 D " c a� v ') 0 0 Q 7 N 7 O d U a WALL LEGENF_,) 0 °'o0'av'��cwl"u NEW SERVICE POD COUNTER SEE SHEET AIA DETAILS. 2 FUTURE BAKED GOODS AREA 3 EXISTING EQUIPMENT 4. FULL HEIGHT WALL EXTENTION 5. KES TO PROVIDE NEW ABS 2.0 W/ TEA TABLE 6. NEW/RELOCATED HAND SINK. VERIFY WITH KES 1. NEW VALANCE WALL 8 MCCAFE BRTAND PANEL TO BE PLACED ADJACENT TO PICK UP PER USRD STANDARDS 9. ORB MONITOR TO BE CENTERED ON PICK UP COUNTER 10. KES TO PROVIDE NEW 14" X 30" LANDING CART 11. KES TO PROVIDE NEW 48" DIGITAL ASSEMBLY CART W/ FRIDGE 12. KES TO PROVIDE NEW BLZ 4 FINISHING STATION 13. RELOCATED EXISTING EQUIPMENT 14. NEW EQUIPMENT - VERIFY WITH KES 15. NEW AMENITY STATION 1 FLOOR PLAN 1.0 /4 11_ 1 1_ 0 I I GENERAL NOTES 1. EXTERIOR DIMENSIONS ARE TO COLUMN REFERENCE LINES AND/OR FACE OF FOUNDATION WALLS UNLESS NOTED OTHERWISE. 2. INTERIOR DIMENSIONS ARE TO FACE OF FINISH WALL. 3. DO NOT SCALE DRAWINGS. 4. MINIMUM INTERIOR FINISH CLASSIFICATION: OCCUPANCY A2 NONSPRINKLERED EXIT ENCLOSURES AND EXIT PASSAGEWAYS: A CORRIDORS: A ROOMS AND ENCLOSED SPACES: B 5. GYP BD TO BE USED ON DINING SIDE OF INTERIOR PARTITIONS UNO 6. MATCH EXISTING FINISHES UNO TYP. 1. GC TO REQUEST t FOLLOW ADA REPORT WHEN AVAILABLE S. AS -GUILTS BASED ON PLANS FROM HtK DALLAS INC. S. SEATING LAYOUT / DIMENSIONS BASED ON PLANS PROVIDED BY ISI 10. ADJUST LOCATION OF KIOSK SO TOP PLATE IS FULLY ON/OR OFF THE SOFFIT (AVOID CEILING CHANGE) I1, NEW FLOOR, CEILING AND DECOR, REFER TO DECOR PLANS 12. LOW VOLTAGE WIRING BY OWNER OPERATOR IF REQUIRED UNDER SEPARATE PERMIT TYP. 13. GC TO PROVIDE ADA SIGNAGE PACKAGE AND INSTALL SIGNS At LOCATIONS AND POSITIONS INDICATED IN PACKAGE OR AS REQUIRED BY LOCAL CODES. SIGNAGE PACKAGE SUPPLIED BY: FORREST PERMA-SIGN, 1-OM-214-8165 9292 1ST St, BOX 588, NEW ROCHELLE, NY 10802 www.Porreetpm mesign6,com w ® v o;° v v o 0 ° (u0 EXISTING CONSTRUCTION at��wuU W z °" ` 0 °' Z c cz tY H a3 aim a. _ NEW CONSTRUCTION A � wN _ ------- L---------------- J CONSTRUCTION ABOVE 3 M w 383 a- N 6 r CS1 W W C) N LATERAL BRACING TO I I CONT. RUNNER CHANNEL STRUCT. ABOVE ; i FIRESTOPPING AT EXTENT Or- 0 4-0" O.C. BACKUP (TYP) V _ = Z I I MTL STUD PARTITION TYPE: N 1/2" GYP BD OR CLG AS ALL PARTITIONS TYPE 'A' Q PLYWOOD BACKUP SCHEDULED UNLESS NOTED OTHERWISE O m EACH SIDE AS O INDICATED ON FINISH "A" 3 5/8" [ c SC 4ED "Al"■ 3 5/8" W/BATT INS. QZ 11511 i 9,11 "Bl"■ 6" W/BATT INS. 11r it . all "CI"• 8" W/BATT INS. LLI 0 04 :2STUD FLOOR AS SPACING: 16" O.C. Li SCHEDULED STUD GUAGE: wM LOAD BEARING: I6 w v • , . NON -LOAD BEARING: 20 O w w Q � o � �I J o Vf 2 INTERIOR PARTITION 1802.31 i 1.0 3/4II_II_OII _ru fL/ m AA-0003276 ❑A /� I PROPOSED SEATING PLAN A1.2 1/4II_I1_OII BEATING RATIO NUMBER OF SEATS SO SEATS HANDICAPPED SEATS REQUIRED 4 C� HANDICAPPED SEATS PROVIDED 4 NOTE: THIS DRAWING IS BASED ON THE DIMENSIONAL INFORMATION PROVIDED 5Y ISI, 5ASED ON THEIR FIELD VERIFICATIONS. CONTRACTOR TO VERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTION. m >- M z O H rZ U N W 0 z 0 N_ Ir cr 0 W 0 old N W M N Lv M Q O Q' .F. • e O Q U O 3 • 0. `n _ m U 00 �w a Q. 00 a . �e v G o v U O NCLCL)� o � o�ao O c N N O C c E � 00 °.�35—o m N o O O .y .N L vj ++ u c U Q) E ',N_+ v °°' o N N , 3 O•c ° c °, a O N . +, U . 0 O O'# y C O 0° U c L —+' C � Off+• O p U O p c 0 y 0 c C d 0 c r Lo ° C U'C ° y O O++ x— c° U C N t O c C U H � � i 7 0 J C O ° r U Q C U v).2 N ° c N° O U=� �c as-° U C O N fn y .u1 .` 4_ 0 _ U c O Q° O O O O D 0 0= o 7 0�� U ° aU UO ;' � � c T,i— 0 L� O O 0.0 ° p O W �' N -° N O = N Q1 0 7 Vf O O_ N O .L L �O N O W i H a3 c� ai5 a �o N W tn 3� O06 WV� 0 a a � m c a_ z N LLI U CO L W V �, '"` uo w Z N Q re C O W J 04 � 0I U 1802.31 0 rzA 1 .2 AA-0003276 _ __ liylu �ll�r•�..n .R 1-5/8" UNISTRUT w 12" O.G. 2 ROWS STAGGERED ATTACHED TO BOTTOM CHORD OF ROOF JOIST (2 MIN.) 1-5/8" UNISTRUT ATTACHED TO 1-5/8" UNISTRUT POST BASE. CONNECT TUBE STEEL BRACKET TO PLYWOOD WITH (4) 1/4 ZINC I" BOLTS. 3/4" PLYWOOD BACKING: CEILING AS SCHEDULED - CP CURATED PANEL MOUNT PROVIDED TO G.C. BY Sep VENDOR `1� CURATED i=',4NEL INST4LL DET,41L I" VENT HOLE 6" O.C. 6 MTL STUC ON 3/4" PLYWOOD '� A IFP DIGITAL MENU BOARD PEERLESS SMARTMOUNT PORTRAIT WALL MOUNT. INSTALL PER MANUFACTURER'S REQUIREMENTS. LOCATE CENTERED WITHIN NICHE RECESSED 4XI2 LOUVER - GC TO PROVIDE (1) LOUVER PER DMB. CENTER AROUND STUD SPACING. A ON 3/4" PLYWOOD 6 MTL MTL STUDS 0 16" 11 5ECTI0N 6 11: 1.5 III : 1'-mll QAl 17N I/A" N rL 1 F.R.P. OVER 1/2" PLYWO. ---'■ EXTEND (o" ABOVE CLG. LINE RECESSED FENDER -� WASHER 6" VERT. STRUT 0 16"OC W/ 1/2" THREADED ROD 4'-VOC MON BRAC CLIP' CEILING AS SCHEDULED ACCESS NEW VALANCE - ALIGN SY. WITH NEW DIGITAL MENU BOARD WALL ACCESSORY SYSTEM WITH LEVELING; CONTROL NEW TILE OVER )P W U U INSTALLATION CEMENT BOARD MOUNTING CONT, (2) 2x6 PLATE • _ ® SUPPORTS 14 V4LANCE 5ECTION �1.5 111 : 1'-mll ICG A PERFORATED PANEL t SUPPORTS BY DECOR ON 3/4" PLYWOOD BEHIND BRACKET A MTL STUDS +� 16" O.G. AT RECESS PEERLESS SMARTMOUNT PORTRAIT WALL MOUNT. INSTALL PER MANUFACTURER'S REQUIREMENTS. LOCATE CENTERED WITHIN NICHE DIGITAL BOARD 6 MTL STUD STUD PARTITION AND 15ER 10 PLAN 's MERCHAND 15ER U � Z w U u 4u-W ► 0 ° iu LLZW2 u- cn a XX w 901 Ira @A1.5 CURATED VIEW PANEL 1/411 = I'-mll KE'*I"' NOTE5 CORNER GUARD: 3/4" ANGLE BY DECOR x— COLOR: A = BLACK CORIAN: ® X_ COLOR: A = CORIAN CAMEO WHITE BY GC B CORIAN DEEP TITANIUM BY GC a 0 4'-01/4" 1]7 �- — — Fr � > CENTER 5LAND 41 -0II U _j Z w U u-Q u III _ 0 t-wLZ W~ u d) X QX w go CURATED VIEW PANEL A1.5 1/4" = I'-V I DIGITAL MERCHANDISER / MENU BOARD WALL BRACKET • SECURE TO STUDS OR 3/4" PLYWOOD BACKING FOLLOW MANUFACTURER'S INSTALLATION INSTRUCTIONS (13 D 1I TAL BOARD "RACKET 11.� III : 1'-mll g NOT U5ED 4RRY TILE COVE SE r: SCHLUTER EX-AHK KITCHEN ELEVATION WALL TILE: CROSSVILLE - COLOR BY NUMBERS cT COLOR: INTUITIVE GRAY. SIZE: 4"xi2", PATTERN: RUNNING B BOND GROUT: MAPEI 02 PEWTER - JOINT TO BE X(," MAX. USE THIS TILE WHEN HIGH LRV IS REQUIRED COORDINATE WITH THE McDONALD'S AREA CONSTRUCTION MANAGER FIBERGLASS REINFORCED PLASTIC (FRP) - PANOLAM, D GRAY SMOOTH, CLASS C, Z 15. REFER TO ROOM FINISH SCHEDULE SHEET A6.1 FOR INSTALLATION LOCATIONS. FOR ORDERING, CONTACT KIMBERLY LAWSON KfmberlylieLawson*panolamzom 1-866-S25-43-11 I] FRONT COUNTER ------ --- FURNISHED t INSTALLED BY DECOR I II VENDOR _ I ►I e I I I N I I I I II II REMOVABLE LAMINATE KICK PLATE QUARRY— DINING ROOM TILE I TILE 12 5ECTION f SERVICE POD g NOT USED I \A1.5/ III O II-mll ORDER READY BOARD. CENTER BETWEEN COUNTER (;Al AND F/ McCAFE WALL PICK-UP COUNTERt B CP DECAL 4 SERVICE AREA ELEVATION A1.5 1/4" = I'-m" LAMINATE: ® X_ COLOR: A - IDMB / DIG. MERCH., SMOOTH BLACK PLASTIC LAMINATE BY GC B = TRASH/ CONE), WHITE PLASTIC LAMINATE BY GC C = TRASH/ COND., LAMITECH GRAPHITE K MATTE FINISH BY GC D = SEE DECOR DRAWINGS. MFR BY DECOR. PURCHASE AND INSTALL BY GC E = McDELVIERY UNDERSCORE, LAMITECH GOLDEN F = BASE BOARD, FORMICA COMPACT LAMINATE MATTE BLACK BY GC DE McDELIVERY OR PICKUP DECAL BY GC ORDER FROM ANN BOWEN WITH VOMELA: ann bowenavomela com SERVICE POD OUTLINE -KNEE WALL BY GC F QUARRY TILE COVE BASE ALT: SCHLUTER DILEX-AHK 1 FRONT COUNTER PLAN ,41.5 1/2" = 1'-0" DIA PLAYER TALLED BEHIND REENt REFER TO INUF. INSTRUCTIONS BY GC :K-UP )UNTERt BY CP 3 PICKUP AREA ELEVATION A1.5 1/4" = 1'-0" GENERAL NOTES • ALL WALL LAMINATE PANELING MANUFACTURED BY DECOR PURCHASE AND INSTALL BY GC UNO • AtE TO VERIFY LOCATION AND QUANTITY OF LIGHTS AND DIFFUSERS AFTER SERVICE AREA WALL ADDITION 1-1 "" 'DECOR LINE OF COUNTERTOP (3411 A.F.F.) DDULAR FRONT COUNTER IRNISHED # INSTALLED Y 161 PICKUP COUNTER BY GC MET, PANEL t E C BY Gc F 2 SERVICE A A1.5 1/4" = r-0" A ELEVATION 1 ENTIRE SHEET CHANGED z O H U w 0 4.o U. • e • M L • • 0 U �. ' • C �a • F, �J./ • • • J —F—J • y 00 m • — • •cu w L c— x� M U. ~g W •Un M a � • . 2 d, • • � o U U O N J L 7-0 O N N � Col. 0 Q 'C a a. O a) V .�.. N J 0 oo °o�ov Uao ai o O O �► O •� 3 ._ p Q a a N N a1 0 O.O N -� _O 7 O •� tv O .2 — V� o C a N 0 0 0 3 .,, O �• OO U C O C L —+� C L O'V+. U C O t 2 p 0 O C N c c a am o C U p - Ox O p O y V C a) N O J ~' •C O O a c� (0, - (n O •N C C O O UD_� vo a) lo d_O U C F O to tn .�� pw U C o�o°' oooma=oa,p 0 O a U N U C N O t� -p O o o3Cc: 7000 ® v 2_ N y O N 7 U 8rn a O N n a) O � ` + N a) p W N N z� j W Q N U) �� N 6N �� 0 12 o o Lo M 0 cx N ry Sp O N W Get z N W N Z to o O 0 :20 U W U F' ry w= $ x N 0 O o m z U a us oC-1 W <p� G 0 8 8 1802.31 0 z A 1 5 rn AA-0003276 R1� ul-1!" GENERAL NOTES SYMBOLS & IDENTIFICATION LEGEND FLORIDA 5UILIDING CODE DATA 1. ALL WORK SHALL CONFORM WITH THE LATEST ADOPTED EDITIONS OF THE FLORIDA BUILDING CODE, BUILDING (FBC-B) SEVENTH EDITION (2020), FLORIDA BUILDING CODE, PLUMBING (FBC-P) SEVENTH EDITION (2020), FLORIDA BUILDING CODE, MECHANICAL (FBC-M) SEVENTH EDITION (2020), FLORIDA BUILDING CODE, FUEL GAS (FBG-FG) SEVENTH EDITION (2020), FLORIDA FIRE PREVENTION CODE (FFPC) SEVENTH EDITION (2020), NATIONAL ELECTRICAL CODE (NEC) 201"1 EDITION, NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) 1 - FIRE CODE (2018), NFPA 101 - LIFE SAFETY CODE 2018, FLORIDA ACCESSIBILITY CODE SEVENTH EDITION (2020) t ALL OTHER APPLICABLE LOCAL, STATE, t FEDERAL CODES t ORDINANCES t ALL AUTHORITIES HAVING LOCAL JURISDICTION. 2. THESE CONSTRUCTION DOCUMENTS HAVE BEEN PREPARED FROM THE MOST COMPLETE INFORMATION AVAILABLE TO THE ARCHITECT. ALL DATA ON EXISTING CONSTRUCTION CONDITIONS ARE APPROXIMATE t SHALL BE VERIFIED PRIOR TO COMMENCING ANY WORK 3. It SHALL BE THE SUBCONTRACTOR'S RESPONSIBILITY TO PERSONALLY FIELD INSPECT THE JOB SITE PRIOR TO SUBMITTING HIS BID. THE INSPECTION IS REQUIRED SO THAT THE CONTRACTOR SHALL BE TOTALLY FAMILIAR W/ THE EXISTING CONDITIONS t THEIR INTERFACE W/ THE NEW CONSTRUCTION AS DEFINED IN THESE CONSTRUCTION DOCUMENTS. 4. THE SUBCONTRACTOR SHALL PERFORM ALL WORK IN ACCORDANCE W/ THE LATEST EDITION OF THE GENERAL CONDITIONS OF THE CONTRACT, AIA DOCUMENT A201. A COPY OF THIS DOCUMENT IS AVAILABLE ® THE CONTRACTORS OFFICE UPON REQUEST. 5. ANY ADJUSTMENT TO THE CONSTRUCTION CONTRACT, ADDITIONS, DELETIONS OR CHANGE ORDERS, SHALL BE APPROVED BY THE OWNER, GENERAL CONTRACTOR, t ARCHITECT IN WRITING. 6. DURING THE CONSTRUCTION PHASE, THE ADMINISTRATION OF THE CONSTRUCTION CONTRACT SHALL BE PERFORMED BY THE MCDONALDS CONSTRUCTION MANAGER -1. ALL WORK (EQUIPMENT, MATERIALS, t LABOR) SHALL HAVE A MINIMUM WRITTEN GUARANTEE FOR A PERIOD OF ONE (1) YEAR, UNLESS SPECIFIED OTHERWISE, FROM THE DATE OF SUBSTANTIAL COMPLETION AGAINST ANY DEFECTS IN SAID WORK, W/ APPROPRIATE REPAIR OR REPLACEMENT 0 NO ADDITIONAL COST TO THE OWNER 8. ALL MATERIALS t EQUIPMENT SHALL BE INSTALLED IN A NEAT t FIRST CLASS WORKMANLIKE MANNER THE ARCHITECT RESERVES THE RIGHT TO DIRECT THE REMOVAL t REPLACEMENT OF ANY ITEM, IN HIS OPINION, THAT DOES NOT PRESENT AN ORDERLY t REASONABLY NEAT OR WORKMANLIKE APPEARANCE. THE REMOVAL t REPLACEMENT SHALL BE DONE WHEN DIRECTED BY THE GENERAL CONTRACTOR, 4 W/OUT ADDITIONAL COST TO THE OWNER S. THE CONTRACTOR SHALL COMPLY W/ THE MANUFACTURER'S INSTRUCTIONS t RECOMMENDATIONS TO THE EXTENT PRINTED INFORMATION IS MORE DETAILED OR STRINGENT THAN REQUIREMENTS CONTAINED DIRECTLY IN THE PLANS. 10. CONTRACTOR SHALL MAINTAIN ORDERLY HOUSEKEEPING DURING THE PROCESS OF CONSTRUCTION t UPON COMPLETION SHALL THROUGHLY CLEAN ALL AREAS. FINAL GLEAN UP SHALL INCLUDE THE FOLLOWING: A. SWEEPING FLOORING. B. DUSTING t REMOVAL OF DIRT, PAINT DRIPPINGS, OIL, GREASE, 4 OTHER BLEMISHES FROM ALL SURFACES, INCLUDING PIPING t EQUIPMENT. C. WINDOWS, GLASS LIGHTS, t MIRRORS SHALL BE WASHED 4 CLEANED. D. PAINT OVERRUNS t PUTTY SMEARS SHALL BE REMOVED. E. HARDWARE SHALL BE CLEANED t POLISHED W/ FLANNEL CLOTH. 11. WORK TO BE DONE CONSISTS OF FURNISHING ALL MATERIALS, LABOR, EQUIPMENT, TOOLS, t ALL ITEMS t SERVICES REQUIRED FOR CONSTRUCTION IN CONFORMITY W/ GENERAL NOTES t PLANS. 12. THE PLANS SHOW THE LOCATION OF ALL FIXTURES t EQUIPMENT t ARE INTENDED TO CONVEY THE GENERAL INTENT OF THE WORK IN SCOPE t LAYOUT. THEY ARE NOT INTENDED TO SHOW IN MINUTE DETAIL EVERY t ALL OF THE ACCESSORIES INTENDED FOR THE PURPOSE OF EXECUTION OF THE WORK, BUT IT IS UNDERSTOOD THAT SUCH DETAILS ARE PART OF THIS WORK 13. THE SUBCONTRACTORS SHALL REMOVE ALL CONSTRUCTION RUBBISH, SCAFFOLDING, EQUIPMENT, TEMPORARY PROTECTION, TEMPORARY FIELD STRUCTURES, t OTHER COMPONENTS WHICH WERE REQUIRED IN CONNECTION W/ THE CONSTRUCTION, BUT NOT A PERMANENT PART THEREOF. 14. THE CONTRACTOR SHALL OBTAIN ALL NECESSARY PERMITS t INSPECTIONS REQUIRED FOR THE WORK ! PAY ALL CHARGES INCIDENTAL THERETO. 15. PROVIDE DOOR HARDWARE IN CONFORMANCE W/ ADA REQUIREMENTS. 16. THE SUBCONTRACTOR SHALL FURNISH ALL MISCELLANEOUS FACILITIES AS NEEDED, INCLUDING TEMPORARY STAIRS, TEMPORARY RAMPS, LADDERS, RUNWAYS, STAGING, SHORING, SCAFFOLDING, BRIDGES, RAILING, BRACING, BARRIERS, CLOSURES, PLATFORMS, TEMPORARY PARTITIONS, WASTE CHUTES, t SIMILAR ITEMS. 11. THE SUBCONTRACTOR SHALL PROTECT ALL CONSTRUCTION COMPONENTS DURING THE COURSE OF PAINTING t SHALL PROMPTLY CLEAN ALL RESIDUE, SPLATTER OR OVERSPRAY UPON COMPLETION OF HIS WORK. THE CONTRACTOR SHALL USE DROP CLOTHS, MASKING, t OTHER SHIELDING DEVICES TO THE GREATEST EXTENT PRACTICAL TO PROTECT ALL ITEMS NOT TO BE PAINTED OR THOSE ITEMS WHICH HAVE ALREADY RECIEVED FINAL FINISH COATS. IS, ALL PAINTING REQUIRED FOR THIS PROJECT SHALL BE PERFORMED IN ACCORDANCE W/ THE MANUFACTURER'S SPECS FOR PRODUCT HANDLING, SURFACE PREPARATION, PAINTING APPLICATION, CURING/DRYING TIME BETWEEN GOATS, CLEANING t PROTECTION OF PAINTED SURFACES UNTIL THE SOURCE OF CONSTRUCTION IS COMPLETE. PAINT COLORS TO BE SELECTED FOR THESE DOCUMENTS ARE AS MANUFACTURERD BY BY GLIDDEN DIVISION OF SCM CORP., ALTERNATE ACCEPTABLE MFR ARE AS FOLLOWS: BENJAMIN MOORE, D.P.I., RUSTOLEUM, PRATT LAMBERT, SHERWIN-WILLIAMS. 19. ALL DRYWALL PARTITIONS ARE DIMENSIONED CENTERLINE TO CENTERLINE UNLESS OTHERWISE NOTED. ALL MASONRY PARTITIONS ARE DIMENSIONED OUT TO OUT. 20. ELECTRICAL PANELS, FIRE EXTINGUISHER CABINETS, ETC., LOCATED IN RATED PARTITIONS SHALL BE BACKED W/ DRYWALL AS REQUIRED TO MAINTAIN RATING. CONTRACTOR TO VERIFY WALL THICKNESSES REQUIRED FOR ALL ELECTRICAL PANELS, FIRE EXTINGUISHER PANELS, ETC. 21. PROVIDE DOUBLE STUDS t BLOCKING WHERE REQUIRED TO SUPPORT MISCELLANEOUS ITEMS, I.E. TYPICAL CASEWORK, CABINETS, GRAB BARS, ETC. CONTRACTOR SHALL FURNISH < INSTALL ALL BACK-UP SUPPORTS 22, DO NOT SCALE DRAWINGS. IF DIMENSIONS ARE IN QUESTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING CLARIFICATION FROM THE OWNER'S REPRESENATIVE BEFORE CONTINUING W/ CONST. 23. CONTRACTOR SHALL VERIFY ALL DIMENSIONS t COORDINATE ALL TRADES. 24. CONTRACTOR SHALL VERIFY ALL EQUIPMENT LOCATIONS 4 DIMENSIONS OF EQUIPMENT. 25. REVIEW ALL ELECTRICAL LOCATIONS W/ OWNER BEFORE SIGN OFF FOR DRYWALL. 26. ALL THRESHOLDS t FLOOR FINISH CHANGES TO BE PLACED UNDER CENTERLINE OF DOOR UNLESS OTHERWISE NOTED. 21. COORDINATE TELEPHONE t SECURITY W/ OWNER BEFORE PROCEEDING. 28, ROOF CONSTRUCTION IS NOT LIGHT FRAME TRUSS 29. A SEPARATE PERMIT SHALL BE REQUIRED FOR THE FIRE SUPPRESSION SYSTEM 30. ALL INSULATION MATERIALS TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 25 AND A SMOKE -DEVELOPED INDEX OF NOT MORE THAN 450 PER THE FBG -1192 31. CONCRETE FLOOR SLAB REPLACEMENT SHALL BE 5" CONC. SLAB W/ 6X6-WIAXW1.4 WWF ON 6 MIL VAPOR BARRIER OVER 12" MIN. CLEAN COMPACTED FILL W/ TERMITE TREATMENT. TIE NEW SLAB INTO EXISTING SLAB/STRUCTURE W/ 03 * 2'-0". EPDXY W/ MIN. 6" EMBED. ROOM IDENTIFICATION DRAWING IDENTIFICATION INTERIOR/CASEWORK ELEVATION IDENTIFICATION SECTION CUT INDICATION PLAN OR SECTION DETAIL INDICATION ROOM NAME FLOOR / LEVEL 201 ROOM NUMBER 2 DRAWING NUMBER SHEET NUMBER ,4(0 DRAWING NUMBER 2-A4 INDICATION OF DIRECTION SHEET NUMBER 3 DRAWING NUMBER INDICATION OF DIRECTION r4ro SHEET NUMBER / `\\ DRAWING NUMBER 3 DETAILED AREA SHEET NUMBER SUPPLEMENTARY DRAWING INDICATION (BOUND IN PROJECT MANUAL). ELEVATION, SECTION CUT, t PLAN DETAIL NOTATIONS SIMILAR TO ABOVE 22 DOOR IDENTIFICATION 22 WINDOW/GLAZING IDENTIFICATION O SPECIFIC NOTES O GENERAL NOTES 10. FURNITURE 4/OR EQUIPMENT F 101 IDENTIFICATION ELEVATION SYMBOL REVISION SYMBOL PARTITION TAG DRAWING NUMBER PAGE NUMBER SEE SCHEDULE SEE SCHEDULE NOTES WHICH APPLY TO SPECIFIC ITEM OR ITEMS ON THE DRWG WHERE INDICATED NOTES WHICH APPLY TO ALL DRAWINGS SEE SCHEDULE FIN FLOOR ELEVATION HEIGHT ELEV 100'-0" SURFACE DESCRIPTION pl REVISION NUMBER DATE REVISED a -DRAWING NUMBER MATERIAL DE5IGNATION5 ELEVATION /FLAN SECTION ®CERAMIC ® GLAZING TILE/ QUARRY TILE III-1 I - I EARTH MASONRY IIIIIIIIIIIIIIIIII Bill ll!iilii� III11ill� - [BLOCKBOND CONCRETE/ STUCCO/ GROUT ®ONT WOOD BLOCKING CUT STONE ®METAL (LARGE SCALE) CLASSIFICATION BY OCCUPANCY MIXED OCCUPANCY NO TYPE OF CONSTRUCTION PROTECTED - HR SPRINKLERED ❑ YES ASSEMBLY GROUP SEPARATION BY OCCUPANCY UNPROTECTED NO A-2 NONE V BUILDING VARIABLES REQUIRED t ALLOWED PROVIDED BUILDING HEIGHT t HEIGHT INCREASES 40' NUMBER OF STORIES I 1 BUILDING AREA / 3,9'19 GSFt + FLOOR AREA INCREASES 6000 G5F 3511 GSF FREEZER/COOLER A OCCUPANT LOAD / FLOOR AREA / PERSON " OF FIXED SEATS 80 ERSONS ASSEMBLY TOTAL SEATING / PERSON N/A N/A A EGRESS WIDTH / PERSON 1ST FLR I( 16" Joel, LENGTH OF DEAD END 20' o' MAXIMUM DISTANCE TO AN EXIT 200' So' MINIMUM NUMBER OF EXITS 2 2 FIRE PROTECTION REQUIREMENTS STRUCTURAL FRAME - INCLUDING 0 0 COLUMNS, GIRDERS, TRUSSES BEARING WALLS - EXTERIOR 0 0 INTERIOR 0 0 NONBEARING WALLS AND PARTITIONS - EXTERIOR >_30 0 0 NONBEARING WALLS AND PARTITIONS - INTERIOR 0 0 FLOOR CONSTRUCTION - INCLUDING SUPPORTING BEAMS t JOINTS o 0 ROOF CONSTRUCTION - INCLUDING SUPPORTING BEAMS s JOINTS 0 0 FLORIDA PLUM5ING CODE DATA OCCUPANCY RESTAURANTS FIXTURES WATER CLOSETS URINALS LAVATORIES DRINKING FOUNTAINS REQUIRED t ALLOWED PROVIDED MALE/FEMALE MALE/FEMALE 4 3 - 1 2 4 nv ^ v n^ ^ TERRAZZO IIIIIIIIIIIIIIIIII - • PLYWOOD (LARGE SCALE) QLIGHTWEIGHT � GYPSUM BD./ CONCRETE PLASTER/ STUCCO a STRUCTURAL WOOD CONCRETE BLOCKING INDEX OF DRAWING5 ARCHITECTURAL CS COVER SHEET ARI AR SHEET DI DEMOLITION PLAN AND NOTES AID FLOOR PLAN AND NOTES ALI / Q Al2 PROPOSED SEATING PLAN A13 I T P AN5, ELEVATIONS, AND DETAILS AIA N/A A2.0 ELEVATIONS ,42.1 ELEVATIONS ELECTRICAL. EI.o ELECTRICAL LIGHTING PLAN / SCHEDULE E2.0 ELECTRICAL POWER PLAN E3.0 ELECTRICAL SCHEDULE E4.0 ELECTRICAL DETAILS <ITCHEN EIQUIPMENT KID KITCHEN COVER K2.o EQUIPMENT PLAN K3.0 EQUIPMENT SCHEDULE ALL WORK SHALL CCP✓IpLY' vUITH PREVAILING CODES FLORIDA BUILDING CODE, NAT1014AL ELECTRIC CODE ANC.+ THE CITY OF ;lr_PHYRHILLS TYOF BU/LDING p F� RHI��S C/At ARCS1TECTURAL A55REVIATION6 AFF ABOVE FINISHED FLOOR Cl CAST IRON ON DOWN FT FEET PC HANDICAPPED MEGH MECHANICAL OD OUTSIDE DIAMETER SCH SCHEDULE TH THRESHOLD ADJ ADJUSTABLE CB CATCH BASIN DWG DRAWING FND FEMININE NAPKIN DISPOSAL HWD HARDWARE MT METAL SNT SEALANT TKBD TACKBOARD AC AIR CONDITIONER CLG CEILING OF DRINKING FOUNTAIN FNV FEMININE NAPKIN VENDOR HT HEIGHT MF METAL FRAME PBML PAPER -BACKED METAL LATH SHT SHEET TPH TOILET PAPER HOLDER ALT ALTERNATE GEM CEMENT FIN FINISH HORIZ HORIZONTAL MRD METAL ROOF DECK PTO PAPER TOLL DISPENSER SHO SHOWER T t G TONGUE < GROOVE ALUM ALUMINUM C. CENTERLINE EA EACH FE FIRE EXTINGUISHER MIN MINIMUM PTH PAPER TOWEL HOLDER SHOC SHOWER CONTROLS TB TOWEL BAR AB ANCHOR BOLT CHBD CHALKBOARD E EAST FECR FIRE EXTINGUISHER INCL INCLUDE M MIRROR PLAS PLASTER SHOP SHOWER HEAD TYP TYPICAL UNLESS t AND CLO CLOSET ELEG ELECTRICAL CABINET RECESSED ID INSIDE DIAMETER MISC MISCELLANEOUS PLYWO PLYWOOD SIM SIMILAR OTHERWISE NOTED L ANGLE CH COAT HOOK END ELECTRIC HAND DRYER FH FIRE HYDRANT MR MOISTURE RESISTANT Pt PRESSURE TREATED SO SOAP DISPENSER U URINAL APPROX APPROXIMATELY COL COLUMN EWC ELECTRIC WATER COOLER FL FLOOR JT JOINT MBH MOP t BROOM HOLDER SH SOAP HOLDER AT CONC CONCRETE ELEV ELEVATION FD FLOOR DRAIN MTD MOUNTED R RADIUS S SOUTH VERT VERTICAL CONST CONSTRUCTION ENCL ENCLOSED / ENCLOSURE FTG FOOTING LAM LAMINATE RPTD RECESSED PAPER SPECS SPECIFICATIONS CONT CONTINUOUS EQ EQUAL FM FRAMED MIRROR LAV LAVATORY N NORTH TOWEL DISPENSER SQ SQUARE WR WASTE RECEPTICAL BD BOARD CONTR CONTRACTOR EQUIP EQUIPMENT NIC NOT IN CONTRACT RECT RECTANGULAR SS STAINLESS STEEL WC WATER CLOSET BM BEAM GJ CONTROL JOINT EXIST EXISTING GALV GALVANIZED MH MAN HOLE NTS NOT t0 SALE REINF REINFORCEMENT STD STANDARD WH WATER HEATER BLK BLOCK EJ EXPANSION JOINT GA GAUGE MFR MANFACTURER NO NUMBER Rr=QD REQUIRED STL STEEL W WEST MIRK BRICK DTL DETAIL EXP EXPOSED GB GRAB BAR MO MASONRY OPENING RD ROOF DRAIN STIR STRUCTURAL W/ WITH E ldJG BI�I�FNV? DIA �oDIAMETER EXT EXTERIOR GWB GYPSUM WALLBOARD MATL MATERIAL OC ON CENTER RM ROOM SMS STRUCTURAL METAL W/O WITHOUT CPT CARPET DIM DIMENSION EGCB EXTERIOR GYPSUM GYP GYPSUM MAX MAXIMUM OPNG OPENING RO ROUGH OPENING STUD DR DOOR CEILING BOARD z 0 0 0 w 0 O, -. �to,0 ; ol , o • o O • M L nn�l W • � 3 • • � 3 �a + U• • >1 > T • N 00 • • • N i~ w m LmM C) • o� L. .zM w • U v Y O _I i' 73 'v w- N C N _jV -O O 2) -0 O O O Q •c Do- av 0 Q. v vs J N ua�Qvv � o � aaj� --Ova O O •p U O. O v (D �oOc Q 0 "J a U C N L U N a E+' O C.O N O O •- N Q O '3 0 O O Q O U C �E (11 C ) v 0 O 0 0 C 211 -a c v cvvoo 0 ocx._ O J .0 w O O �7 N U Q C � � V .•= (n O •(� O C � O O u�" �` N O U N (U N O_ N.Nw C Z.U- Q N O U O N oQ�m,oa,� V v n ao �, m � o - CL w O p 3 0 O O �d Vvmv ago t017 N 0 7 to O.0 V a a _ N > N I- aof- a c ?N N 3 j W d W� N Qc6 � 0 04 t � M M 0 w N Q 0 m O N O � gz N Ld � � d ch(o r� O o Q U LLJ U tc) ct w = �� N O a u � W. 00 Q L(A) o o� o 00 a v�i o 1802.31 6 z x AR1 V) AA-0003276 ." ❑ ❑ F!�_I Jam, ...r- rr �+� I , I I I I I 0 0 (------------, I I I I I I I I I O O I o I I I 5 i 9EI �\ SB - DPX 61"A.F.F. I I I 1 I I ❑ I I ------------� ---------F11 f-1 TL -IG - Di 61' A.F 0 ----'`-`-- 16'-1 1/2" VERIFY 3 3 :1�1= � I I I i I I I I I I � I I rat &L-I 1/2" �1/4- , 6'-�13/4" a 3 3 D HE o 0 0 0 0 a 0 I I 0 o 0 0 0 0 GENERAL NOTES: I. ALL EXIT DOORS SHALL BE KEYLESS IN THE DIRECTION OF EGRESS. 2. THE OPENING FORCE OF ALL EXP. PUGH/PULl- DOOR'S SHALL NOT EXCEED 81/2 LBB. 3. THE OPENING FORCE OF ALL INTERIOR PUSH/PULL DOORS SHALL NOT EXCEED 5 LB$. 4. PROVIDE PANIC HARDWARE FOR ALL EXTERIOR DOORS AS NOTED ON THE DOOR SCHEDULE. 5. ALL DOOR HARDWARE SHALL NOT REaJIRE TIGHT GRASPING, TIGHT PINCHING OR TWISTING OF THE WRIST TO OPERATE. DOOR m 1. 1 EA CLOSER LCN 4021 x 18 2. 3 EA HINGES OFFSET PIVOT ANSI-A-156.4 GRADE It PROVIDE EXPOSED PARTS OF CAST ALUMINUM ALLOY, AS SUPPLIED BY DOOR MANUFACTURER 3. 1 EA PUSWPULL HANDLE KAWNEER OCO-S OR HAGER PUSH/PULL SET 164D/V/6. 4. N/A 5. 1 EA THRESHOLD NATIONAL GUARD PRODUCTS, INC. SADDLE TYPE THRESHOLD 325, U 36" WIDE x I/2" RISE (ADA ACCESSIBLE). 6. 1 EA FEATHER STRIPPING: PROVIDE COMPRESSION WEATHER STRIPPING AGAINST FIXED STOPS. AT OTHER EDGES PROVIDE SLIDING WEATHER STRIPPING RETAINED N ADJUSTABLE STRIP MORTISED INTO DOOR EDGE. PROVIDE EPOM OR VINYL GASKET WEATHER STRIPPING IN BOTTOM DOOR RAIL ADJUSTABLE FOR CONTACT W/ THRESHOLD. nQ1. 1 EA SIGN MOUNT ONTO DOOR, TO READ "THIS DOOR MUST REMAIN UNLOCKED WHENEVER ,, THE BUILDING IS OCCUPIEDAXPM BUSINESS HOURS." 1E-- �G mme I. 1 EA HINGE 1W-112HO 83" ALUM HAGER 8. I EA TREADPLATE 24 X 34 UMCO 2. 1 EA CLOSER 1461 RbrA ALUM LON S. I EA VIEW FRAME LFRAI00 6 X 21 fl/ 3. 1 EA LOCK ND80PD RHO 626 SCR -AGE DKB NGUARD 4. 1 EA ELEC STRIKE 621124V DC FOE U5320 SCHLAGE 10.1 EA GLASS 5 X 26 X 1/4 UMCO 5. 1 EA PWR SUPPLY PM SCHLAGE It. I EA GLASS 5 X 26 X 1/4 UMCO O6. 1 EA DOOR BELL 5OV-24P SURFACE MOUNTED 1. 3 EA PUSH BUTTON 621-RD-DA HDP 626 SCHLAGE 9EI �\ SB - DPX 61"A.F.F. I I I 1 I I ❑ I I ------------� ---------F11 f-1 TL -IG - Di 61' A.F 0 ----'`-`-- 16'-1 1/2" VERIFY 3 3 :1�1= � I I I i I I I I I I � I I rat &L-I 1/2" �1/4- , 6'-�13/4" a 3 3 D HE o 0 0 0 0 a 0 I I 0 o 0 0 0 0 GENERAL NOTES: I. ALL EXIT DOORS SHALL BE KEYLESS IN THE DIRECTION OF EGRESS. 2. THE OPENING FORCE OF ALL EXP. PUGH/PULl- DOOR'S SHALL NOT EXCEED 81/2 LBB. 3. THE OPENING FORCE OF ALL INTERIOR PUSH/PULL DOORS SHALL NOT EXCEED 5 LB$. 4. PROVIDE PANIC HARDWARE FOR ALL EXTERIOR DOORS AS NOTED ON THE DOOR SCHEDULE. 5. ALL DOOR HARDWARE SHALL NOT REaJIRE TIGHT GRASPING, TIGHT PINCHING OR TWISTING OF THE WRIST TO OPERATE. DOOR m 1. 1 EA CLOSER LCN 4021 x 18 2. 3 EA HINGES OFFSET PIVOT ANSI-A-156.4 GRADE It PROVIDE EXPOSED PARTS OF CAST ALUMINUM ALLOY, AS SUPPLIED BY DOOR MANUFACTURER 3. 1 EA PUSWPULL HANDLE KAWNEER OCO-S OR HAGER PUSH/PULL SET 164D/V/6. 4. N/A 5. 1 EA THRESHOLD NATIONAL GUARD PRODUCTS, INC. SADDLE TYPE THRESHOLD 325, U 36" WIDE x I/2" RISE (ADA ACCESSIBLE). 6. 1 EA FEATHER STRIPPING: PROVIDE COMPRESSION WEATHER STRIPPING AGAINST FIXED STOPS. AT OTHER EDGES PROVIDE SLIDING WEATHER STRIPPING RETAINED N ADJUSTABLE STRIP MORTISED INTO DOOR EDGE. PROVIDE EPOM OR VINYL GASKET WEATHER STRIPPING IN BOTTOM DOOR RAIL ADJUSTABLE FOR CONTACT W/ THRESHOLD. nQ1. 1 EA SIGN MOUNT ONTO DOOR, TO READ "THIS DOOR MUST REMAIN UNLOCKED WHENEVER ,, THE BUILDING IS OCCUPIEDAXPM BUSINESS HOURS." 1E-- �G mme I. 1 EA HINGE 1W-112HO 83" ALUM HAGER 8. I EA TREADPLATE 24 X 34 UMCO 2. 1 EA CLOSER 1461 RbrA ALUM LON S. I EA VIEW FRAME LFRAI00 6 X 21 fl/ 3. 1 EA LOCK ND80PD RHO 626 SCR -AGE DKB NGUARD 4. 1 EA ELEC STRIKE 621124V DC FOE U5320 SCHLAGE 10.1 EA GLASS 5 X 26 X 1/4 UMCO 5. 1 EA PWR SUPPLY PM SCHLAGE It. I EA GLASS 5 X 26 X 1/4 UMCO O6. 1 EA DOOR BELL 5OV-24P SURFACE MOUNTED 1. 3 EA PUSH BUTTON 621-RD-DA HDP 626 SCHLAGE GENERAL DOOR NOTES: W J� W L 2. 3. 4. 5. 6. GC TO INSTALL ACCESSIBILITY DOOR SIGNS WHERE REGt'D BY LOCAL CODES DETEX ALARM CONTACT SWITCHES SHALL BE RECESSED INTO THE TOP OF THE DOOR 4 HOLLOW METAL FRAME ABOVE. DOORS, DOOR PRAMEB, t HARDWARE POR DOORS 3, 3A, 5, 6, 6A, i, SUPPLIED BY. UNIVERSAL MANUFACTURING 1-WO-821-1414. NOT USED 8E ELEVATIONS AND WALL SECTIONS ALL INTERIOR SOLID CORE WOOD DOORS TO HAVE A LAMINATED FINISH, AS INDICATED PER DECOR OWLS U1. a NOT USED ALL EXTERIOR DOORS SHALL HAVE MAX 114" LEVEL C"W PER MC hve" DOOR FRAME MARK MATERIAL SIZE TYPE MATL SIZE n, !- I ALUM. 3'-0"x1'-0"xl 3/4" A ALUM. (NOTE 6) O 10 HM. 3'-0"x1'-0"xl 3/4" C W.M. 2"JAMB 4"HD 0 Q Cn w // DOOR 1/4" TEMP. - �i N rl n/ GLAZING Q loll STILE - AT BOTTOM C NOTES O NOTE: GENERAL CONTRACTOR SHALL VERIFY ALL SEATING AND DINING DIMENSIONS BEFORE PROCEEDING WITH DECOR INSTALLATION. NOTE: GENERAL CONTRACTOR SHALL INSTALL A POLYETHYLENE BARRIER IN AREAS OF REMODEL WORK THAT REQUIRE DUST PROTECTION. MEANS AND METHODS OF INSTALLING THIS POLYETHYLENE BARRIER SHALL BE PER THE GENERAL CONTRACTOR BASED ON EXISTING FIELD CONDITIONS. j I--il N _ ----------- I I • e 1 �• •ge I I P.S. 1 O }1 I u I O I I �• •� � 20 -9 5 -® I --4=8 I/2 --- +-� --jF- F U 6�I I II �'•••E� xM A13 U 12 13 13 I I I �• .zM a Q • • , �a 14 A13 6 - - AI3 i �, � . A13-----------`° ° -N bi F-1 I I a °.= o L 03 8 -3 P D. \ N a aai ° ° N�jF 61 c 75 v 3 N E'o� v� 0 a C a)U 04 _ � C O cn� C.81. ° Ccx p° O N O _ A2.1 U' 0 -c :t'-- MFGO J~ C w O P U Q =tq,)-0 U� w V) O y = ch O C N O N 'o 7 7 0 7 0.o ° rn O O UUAL L LE G;END o 3- �� c 0 *�: � �u z O a w 0 z 0 D Of Ix 0 U w 0 Is W W M N M Qr r 0 r Q' N a. C-D� A II R� NEW SERVICE POD COUNTER SEE SHEET AIA DETAILS. 2. FUTURE BAKED GOODS AREA 3 EXISTING EQUIPMENT 4. FULL HEIGHT WALL EXTENTION 5. KES TO PROVIDE NEW ABS 2.0 W/ TEA TABLE 6. NEW/RELOCATED HAND SINK. VERIFY WITH KES "I. NEW VALANCE WALL 8 MCCAFE BRTAND PANEL TO BE PLACED ADJACENT TO PICK UP PER USRD STANDARDS S. ORB MONITOR TO BE CENTERED ON PICK UP COUNTER 10. KES TO PROVIDE NEW 14" X 30" LANDING CART 11. KES TO PROVIDE NEW 48" DIGITAL ASSEMBLY CART W/ FRIDGE 12, KES TO PROVIDE NEW BLZ t FINISHING STATION 13. RELOCATED EXISTING EQUIPMENT 14, NEW EQUIPMENT - VERIFY WITH KES 15. NEW AMENITY STATION 1 FLOOR PLAN 1.0) /itll_11-OII GENERAL NOTES 1. EXTERIOR DIMENSIONS ARE TO COLUMN REFERENCE LINES AND/OR FACE OF FOUNDATION WALLS UNLESS NOTED OTHERWISE. 2. INTERIOR DIMENSIONS ARE TO FACE OF FINISH WALL. 3. DO NOT SCALE DRAWINGS. 4. MINIMUM INTERIOR FINISH CLASSIFICATION: OCCUPANCY A2 NONSPRINKLERED EXIT ENCLOSURES AND EXIT PASSAGEWAYS: A CORRIDORS: A ROOMS AND ENCLOSED SPACES: B 5. GYP BD TO BE USED ON DINING SIDE OF INTERIOR PARTITIONS UNO 6. MATCH EXISTING FINISHES UNO TYP. 1. GC TO REQUEST t FOLLOW ADA REPORT WHEN AVAILABLE 8. AS -GUILTS BASED ON PLANS FROM H4K DALLAS INC. S. SEATING LAYOUT / DIMENSIONS BASED ON PLANS PROVIDED BY ISI 10. ADJUST LOCATION OF KIOSK SO TOP PLATE IS FULLY ON/OR OFF THE SOFFIT (AVOID CEILING CHANGE) 11, NEW FLOOR, CEILING AND DECOR, REPER TO DECOR PLANS 12. LOW VOLTAGE WIRING BY OWNER OPERATOR IF REQUIRED UNDER SEPARATE PERMIT TYP. 13. GC TO PROVIDE ADA SIGNAGE PACKAGE AND INSTALL SIGNS AT LOCATIONS AND POSITIONS INDICATED IN PACKAGE OR AS REQUIRED BY LOCAL CODES. SIGNAGE PACKAGE SUPPLIED BY: FORREST PERMA-SIGN, 1-SM-214-8165 43252 1ST ST., BOX 588, NEW ROCHELLE, NY 10802 www.Forre6tpermeelgno com LATERAL - BRACING TO STRUCT. ABOVE • 4-0" O.C. - 1/2" GYP BD OR PLYWOOD BACKUP EACH SIDE AS INDICATED ON FINISH SCHED * � s � 3 pnov,c �n��°i EXISTING CONSTRUCTION U) s ao�r ° `" °' c 0 a - NEW CONSTRUCTION m j N - �----------------� CONSTRUCTION ABOVE 3 w 0 ui N O G Q N M ii CONT. RUNNER CHANNEL FIRESTOPPING AT EXTENT OF BACKUP (TYP) _ MTL STUD PARTITION TYPE: CLG AS ALL PARTITIONS TYPE 'A' < SCHEDULED UNLESS NOTED OTHERWISE m "A" � 3 5/8" "At" 365/8" W/BATT INS. 0- $ 11511 ; N "BI"• roll W/BATT INS. W � � 11CH • 8" "Cl" ■ 8" W/BATT INS. O 0 FLOOR AS STUD SPACING: lro" O.G. :2 LijLo mks mks SCHEDULED STuIp GU,4GI-=; W M LOAD BEARING: 16 F NON -LOAD BEARING: 20 O 1Z N ao 04 o 8S 1802.31 2 IAl .0 NTERIOR PARTITION z SL/ ��'+ AA-0003276 mim 7— I I II II — J z 0 U W a z 0 N 0 U W 0 W M N W Q O — I�j of 4 4,• C) E � O c • s • M Q) • • � 3 y 3 F- � 4� • > �'—• 00 .Ex In M .erg o U. °� z • Q • M a . • -a v 20 a� o -0 J p �� y o• O o O Q d O C ++ 'C aav O O U am ya)o o�oo °'o a)-o ao v y E o o c C 'D a) o vy3�o N � o o- N U c N C N w � y E.� o.r o'o N 0 :2 o O - U � C 1-4c O '3 16 o N 0 C O U C t —+ c � O- y U p p C O t o'+, y o C +L+ co ��. U y — O cc.�CaC C U O,cU C om pU O ++ X rUi , O N U C O r N C 0 C L` U U)J~ C O Z0: O FD o w U QQ C .4: U O U O C a) 0 O V) U Cp .0-N y ,N N U a 0 7 O O a) U v � L o �aa vo c 3 O 0 O �] ® o 2 O u+ " 7� O O 'O 0� j N a) U_ U y a F- O; C+t+U)rt a GO 8 N ) g � SEATING RATIO HANDICAPPED HANDICAPPED o cn L (n o NUMBER OF SEATS SEATS REQUIRED SEATS PROVIDED � N 60 SEATS 4 4 NOTE: THIS DRAWING IS BASED ON THE DIMENSIONAL INFORMATION PROVIDED BY ISI, BASED ON THEIR FIELD � VERIFICATIONS. CONTRACTOR TO VERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTION. Q 0 �z 1 PfizOPOSED SATING fi ��4N Al-2 w�l o L d a U W M 0 Z fn N 00 Q U O W Jo (� O 1802.31 0 z A 1 .2 AA-0003276 m } M 1-5/8" UNISTRUT ® 12" O.G. 2 ROWS STAGGERED ATTACHED TO BOTTOM CHORD OF ROOF JOIST (2 MIN.) 1-5/8" UNISTRUT ATTACHED TO 1-5/8" UNISTRUT POST BASE. CONNECT TUBE STEEL BRACKET TO PLYWOOD WITH (4) 1/4 ZINC I" BOLTS. 3/4" PLYWOOD BACKING CEILING AS SCHEDULED - GP GURATED PANEL MOUNT PROVIDED TO G.G. BY S4D VENDOR 15 CU�'4TED PANEL INST,4LL DETAIL F.R.P. OVER 1/2" PLYWO. ---' EXTEND 6" ABOVE CLG. LINE RECESSED FENDER �\ WASHER I 6" VERT. STRUT * 16"OG _" W/ 1/2" THREADED ROD , 4'-O"OC n 1 ORDER READY BOARD (ORB) WALL BRACKET MONITOR ACCESSORY BRACKET a _ e SYSTEM WITH CLIPS TO 0 0 LEVELING CEILING AS SCHEDULED ACCESSORY - o o CONTROL SYSTEM B NEW VALANCE - ALIGN WITH NEW DIGITAL MENU m BOARD WALL 0 () NEW TILE OVER" _ lJ INSTALLATION CEMENT BOARD MOUNTING CONT. (2) 2x6 PLATE ®. J SUPPORTS DIGITAL MERCHANDISER / MENU BOARD WALL BRACKET 14 V4LANCE SECTION • SECURE TO STUDS OR 3/4" PLYWOOD BACKING • FOLLOW MANUFACTURER'S INSTALLATION INSTRUCTIONS Oup, I �• o I I FRONT COUNTER FURNISHED INSTALLED DECOR VENDOR I II N I II N I II I I� I II I Fw JJ REMOVABLE LAMINATE KICK PLATE QUARRY TILE DINING ROOM TILE 12 SECTION 6 SERVICE POD A1.5 "" 'DECOR LINE OF COUNTERTOP (34" AFF.) ODULAR FRONT COUNTER ISNISHED t INSTALLED Y ISI z O a U V) w z 0 0 cy- U w 0 43 w w M N M Q 0 0 T_� M 61 --1 • . 1 QP_ i I" VENT HOLE � 6" O.G. � (`t: W 6 MTL STU 8 Y'. o ON 3/4" PLYWOOD II '(W 0a , A A IFP DIGITAL MENU BOARD PEERLESS SMARTMOUNT PORTRAIT WALL MOUNT, INSTALL PER MANUFACTURER'S REQUIREMENTS. LOCATE CENTERED WITHIN NICHE RECESSED 4XI2 LOUVER, - GC TO PROVIDE (1) LOUVER PER DMB. CENTER AROUND STUD SPACING. a A ON 3/4" PLYWOOD 4 A 6 MTL STUD MTL STUDS 16" 4 z 00 0 z c) f i 11 SECTION a i" 1ERCHAND ISER -m" 0 p 4'-01/4" P-1 CURATED VIEW PANEL A1.5 1/4" = r-m" KENI' NOTES CORNER GUARD: 3/4" ANGLE BY DECOR q A = BLACK CORIAN: X— COLOR: A - CORIAN CAMEO WHITE BY GC B • CORIAN DEEP TITANIUM BY GC A PERFORATED PANEL 4 SUPPORTS BY DECOR ON 3/4" PLYWOOD ra„ BEHIND BRACKET MTL STUDS i 16" O.G. AT RECESSrL PEERLESS SMARTMOUNT PORTRAIT WALL MOUNT. INSTALL PER MANUFACTURER'S REQUIREMENTS. LOCATE CENTERED WITHIN NICHE DIGITAL BOARD 6 MTL STUD STUD PARTITION 10 PLAN 1" IERCHAND ISER A1.5 0 p e 4'-01/4011 V 7-7 C Z Q > lY U W = CP ii - .o- U H 0 � 0 aL -Lu �7 w? 0X w IIF CENTER ISLAND 4'-0" 0 f(1 co CURATED VIEW PANEL A1.5 1/4" = 1'-0" iv g NOT USED 70. 4RRY TILE COVE SE r: SCHLUTER EX-Al-K 5 KITC1-IEN ELEVATION A1.5 1/4" = 1'-0" ElWALL TILE: CROSSVILLE - COLOR BY NUMBERS COLOR: INTUITIVE GRAY. SIZE: 4"x12", PATTERN: RUNNING B BOND GROUT: MAPEI 02 PEWTER - JOINT TO BE X6" MAX. USE THIS TILE WHEN HIGH LRV IS REQUIRED COORDINATE WITH THE McDONALD'S AREA CONSTRUCTION MANAGER FIBERGLASS REINFORCED PLASTIC (FRP) - PANOLAM, aGRAY SMOOTH, GLASS C, .015. REFER TO ROOM FINISH SCHEDULE SHEET A6.1 FOR INSTALLATION LOCATIONS. FOR ORDERING, CONTACT KIMBERLY LAWSON KlmberIy'/&Lawaon*panolamzom 1-866-925-43"11 S \ NOT USED 1 \ A 1.5 / ORDER READY BOARD. CENTER BETWEEN COUNTER 13 AND F/ McCAFE WALL A1.5, PICK-UP COUNTERt B CP DECAL 4 SERVICE AREA ELEVATION A1.5 J 1/4" = I'-m" LAMINATE: D X— COLOR: A = IDMB / DIG. MERCH., SMOOTH BLACK PLASTIC LAMINATE BY GC B = TRASH/ COND., WHITE PLASTIC LAMINATE BY GC C s TRASH/ COND., LAMITECH GRAPHITE K MATTE FINISH BY GC D = SEE DECOR DRAWINGS. MFR BY DECOR, PURCHASE AND INSTALL BY GC E = MGDELVIERY UNDERSCORE, LAMITECH GOLDEN F = BASE BOARD, FORMICA COMPACT LAMINATE MATTE BLACK BY GC DE McDELIVERY OR PICKUP DECAL BY GC E Fo ORDER FROM ANN BOWEN WITH VOMELA: annbowen*vomelazom SERVICE POD OUTLINE -KNEE WALL BY GC F QUARRY TILE COVE BASE ALT: SCHLUTER DILEX-AHK &IFRONT COUNTER PLAN ' = I'-m" 3 PICKUPAREA GENERAL NOTES • ALL WALL LAMINATE PANELING MANUFACTURED BY DECOR PURCHASE AND INSTALL BY GC UNO • ATE TO VERIFY LOCATION AND QUANTITY OF LIGHTS AND DIFFUSERS AFTER SERVICE AREA WALL ADDITION DIA PLAYER TALLED BEHIND REENt REFER TO NUR INSTRUCTIONS BY GG :K-UP �UNTERt BY CP VAT I ON PICKUP COUNTER BY GC MET PANEL t 1 F 2 SERVICE ,AREA ELEVATION A1.5 J 1/4" = 1'-0" 1 ENTIRE SHEET CHANGED U • u • O c—• � ga • M • 0 3 a tV . • > -}-- • w 00 Ew L c �M in 00 a am Q . • . � v m U coi oa�i J L p p° N C N O O 2+ _ O O N o C Q 'C aao N p U.,L,, >> o to=)voo cn a o o a .r � �� � ao Q a a N N -- 0— O O N-dpLvc•o, U a C O CO �p o ; ° O L O U C p C +-+ C 0"' c N p U O o C O L L 2 t Q� O C Inc c :% o.N p - E- p C U •E o 0 o p o+ x. f/I O U C U L N — O J~ C N p 0 F ° C N 16 U N j,O N c,C c 0 O�.� o�(u c C� is o E °c vai ' `o - U0a cn U 0c O ; o . -' v — o o `3o-0oop w ® o T °'oU,rZ ° a y ° o FL- a'a ° c_c vvi - d c MN N z3: D w�- (nuj D s� �� � Q io6 N u) V) to M 0 J_ 2 a c W L N Q o � m N aJa 0 C� z N C O o O 0 zoa Ld U VF N Lo of w of Z dO w co w 7) 7X o a oc <o QWs 1802.31 0 z A 1 *5 AA-0003276 cruN GENERAL NOTES SYMBOLS 8 IDENTIFICATION LEGEND FLORIDA 5UILDING CODE DATA 1. ALL WORK SHALL CONFORM WITH THE LATEST ADOPTED EDITIONS OF THE FLORIDA BUILDING CODE, BUILDING (FBC-B) SEVENTH EDITION (2020), FLORIDA BUILDING CODE, PLUMBING (FBC-P) SEVENTH EDITION (2020), FLORIDA BUILDING CODE, MECHANICAL (FBC-M) SEVENTH EDITION (2020), FLORIDA BUILDING CODE, FUEL GAS (FBC-FG) SEVENTH EDITION (2020), FLORIDA FIRE PREVENTION CODE (FFPC) SEVENTH EDITION (2020), NATIONAL ELECTRICAL CODE (NEC) 2011 EDITION, NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) 1 - FIRE CODE (2018), NFPA 101 - LIFE SAFETY CODE 2010, FLORIDA ACCESSIBILITY CODE SEVENTH EDITION (2020) 4 ALL OTHER APPLICABLE LOCAL, STATE, 4 FEDERAL CODES a ORDINANCES 4 ALL AUTHORITIES HAVING LOCAL JURISDICTION. 2. THESE CONSTRUCTION DOCUMENTS HAVE BEEN PREPARED FROM THE MOST COMPLETE INFORMATION AVAILABLE TO THE ARCHITECT. ALL DATA ON EXISTING CONSTRUCTION CONDITIONS ARE APPROXIMATE 4 SHALL BE VERIFIED PRIOR TO COMMENCING ANY WORK. 3. IT SHALL BE THE SUBCONTRACTORS RESPONSIBILITY TO PERSONALLY FIELD INSPECT THE JOB SITE PRIOR TO SUBMITTING HIS BID. THE INSPECTION IS REQUIRED SO THAT THE CONTRACTOR SHALL BE TOTALLY FAMILIAR W/ THE EXISTING CONDITIONS 4 THEIR INTERFACE W/ THE NEW CONSTRUCTION AS DEFINED IN THESE CONSTRUCTION DOCUMENTS. 4. THE SUBCONTRACTOR SHALL PERFORM ALL WORK IN ACCORDANCE W/ THE LATEST EDITION OF THE GENERAL CONDITIONS OF THE CONTRACT, AIA DOCUMENT A201. A COPY OF THIS DOCUMENT IS AVAILABLE * THE CONTRACTORS OFFICE UPON REQUEST. 5. ANY ADJUSTMENT TO THE CONSTRUCTION CONTRACT, ADDITIONS, DELETIONS OR CHANGE ORDERS, SHALL BE APPROVED BY THE OWNER, GENERAL CONTRACTOR, 4 ARCHITECT IN WRITING. 6. DURING THE CONSTRUCTION PHASE, THE ADMINISTRATION OF THE CONSTRUCTION CONTRACT SHALL BE PERFORMED BY THE MCDONALDS CONSTRUCTION MANAGER. 1. ALL WORK (EQUIPMENT, MATERIALS, 4 LABOR) SHALL HAVE A MINIMUM WRITTEN GUARANTEE FOR A PERIOD OF ONE (1) YEAR, UNLESS SPECIFIED OTHERWISE, FROM THE DATE OF SUBSTANTIAL COMPLETION AGAINST ANY DEFECTS IN SAID WORK, W/ APPROPRIATE REPAIR OR REPLACEMENT * NO ADDITIONAL COST TO THE OWNER S. ALL MATERIALS 4 EQUIPMENT SHALL BE INSTALLED IN A NEAT 4 FIRST CLASS WORKMANLIKE MANNER THE ARCHITECT RESERVES THE RIGHT TO DIRECT THE REMOVAL 4 REPLACEMENT OF ANY ITEM, IN HIS OPINION, THAT DOES NOT PRESENT AN ORDERLY 4 REASONABLY NEAT OR WORKMANLIKE APPEARANCE. THE REMOVAL 4 REPLACEMENT SHALL BE DONE WHEN DIRECTED BY THE GENERAL CONTRACTOR, 4 W/OUT ADDITIONAL COST TO THE OWNER. S. THE CONTRACTOR SHALL COMPLY W/ THE MANUFACTURER'S INSTRUCTIONS 4 RECOMMENDATIONS TO THE EXTENT PRINTED INFORMATION IS MORE DETAILED OR STRINGENT THAN REQUIREMENTS CONTAINED DIRECTLY IN THE PLANS. 10. CONTRACTOR SHALL MAINTAIN ORDERLY HOUSEKEEPING DURING THE PROCESS OF CONSTRUCTION 4 UPON COMPLETION SHALL THROUGHLY CLEAN ALL AREAS. FINAL CLEAN UP SHALL INCLUDE THE FOLLOWING: A. SWEEPING FLOORING. B. DUSTING 4 REMOVAL OF DIRT, PAINT DRIPPINGS, OIL, GREASE, 4 OTHER BLEMISHES FROM ALL SURFACES, INCLUDING PIPING 4 EQUIPMENT. C. WINDOWS, GLASS LIGHTS, 4 MIRRORS SHALL BE WASHED 4 CLEANED. D. PAINT OVERRUNS 4 PUTTY SMEARS SHALL BE REMOVED. E. HARDWARE SHALL BE CLEANED 4 POLISHED W/ FLANNEL CLOTH. 11. WORK TO BE DONE CONSISTS OF FURNISHING ALL MATERIALS, LABOR, EQUIPMENT, TOOLS, 4 ALL ITEMS 4 SERVICES REQUIRED FOR CONSTRUCTION IN CONFORMITY W/ GENERAL NOTES 4 PLANS. 12. THE PLANS SHOW THE LOCATION OF ALL FIXTURES 4 EQUIPMENT 4 ARE INTENDED TO CONVEY THE GENERAL INTENT OF THE WORK IN SCOPE 4 LAYOUT. THEY ARE NOT INTENDED TO SHOW IN MINUTE DETAIL EVERY 4 ALL OF THE ACCESSORIES INTENDED FOR THE PURPOSE OF EXECUTION OF THE WORK, BUT IT IS UNDERSTOOD THAT SUCH DETAILS ARE PART OF THIS WORW, 13. THE SUBCONTRACTORS SHALL REMOVE ALL CONSTRUCTION RUBBISH, SCAFFOLDING, EQUIPMENT, TEMPORARY PROTECTION, TEMPORARY FIELD STRUCTURES, 4 OTHER COMPONENTS WHICH WERE REQUIRED IN CONNECTION W/ THE CONSTRUCTION, BUT NOT A PERMANENT PART THEREOF. 14. THE CONTRACTOR SHALL OBTAIN ALL NECESSARY PERMITS 4 INSPECTIONS REQUIRED FOR THE WORK 4 PAY ALL CHARGES INCIDENTAL THERETO. 15. PROVIDE DOOR HARDWARE IN CONFORMANCE W/ ADA REQUIREMENTS. 16. THE SUBCONTRACTOR SHALL FURNISH ALL MISCELLANEOUS FACILITIES AS NEEDED, INCLUDING TEMPORARY STAIRS, TEMPORARY RAMPS, LADDERS, RUNWAYS, STAGING, SHORING, SCAFFOLDING, BRIDGES, RAILING, BRACING, BARRIERS, CLOSURES, PLATFORMS, TEMPORARY PARTITIONS, WASTE CHUTES, 4 SIMILAR ITEMS. 11, THE SUBCONTRACTOR SHALL PROTECT ALL CONSTRUCTION COMPONENTS DURING THE COURSE OF PAINTING 4 SHALL PROMPTLY CLEAN ALL RESIDUE, SPLATTER OR OVERSPRAY UPON COMPLETION OF HIS WORK. THE CONTRACTOR SHALL USE DROP CLOTHS, MASKING, 4 OTHER SHIELDING DEVICES TO THE GREATEST EXTENT PRACTICAL TO PROTECT ALL ITEMS NOT TO BE PAINTED OR THOSE ITEMS WHICH HAVE ALREADY RECIEVED FINAL FINISH COATS. 18. ALL PAINTING REQUIRED FOR THIS PROJECT SHALL BE PERFORMED IN ACCORDANCE W/ THE MANUFACTURER'S SPECS FOR PRODUCT HANDLING, SURFACE PREPARATION, PAINTING APPLICATION, CURING/DRYING TIME BETWEEN COATS, CLEANING 4 PROTECTION OF PAINTED SURFACES UNTIL THE SOURCE OF CONSTRUCTION IS COMPLETE. PAINT COLORS TO BE SELECTED FOR THESE DOCUMENTS ARE AS MANUFACTURERD BY BY GLIDDEN DIVISION OF SCM CORP., ALTERNATE ACCEPTABLE MFR ARE AS FOLLOWS: BENJAMIN MOORE, D.P.I., RUSTOLEUM, PRATT LAMBERT, SHERWIN-WILLIAMS. 15. ALL DRYWALL PARTITIONS ARE DIMENSIONED CENTERLINE TO CENTERLINE UNLESS OTHERWISE NOTED. ALL MASONRY PARTITIONS ARE DIMENSIONED OUT TO OUT. 20, ELECTRICAL PANELS, FIRE EXTINGUISHER CABINETS, ETC., LOCATED IN RATED PARTITIONS SHALL BE BACKED W/ DRYWALL AS REQUIRED TO MAINTAIN RATING. CONTRACTOR TO VERIFY WALL THICKNESSES REQUIRED FOR ALL ELECTRICAL PANELS, FIRE EXTINGUISHER PANELS, ETC. 21. PROVIDE DOUBLE STUDS 4 BLOCKING WHERE REQUIRED TO SUPPORT MISCELLANEOUS ITEMS, I.E. TYPICAL CASEWORK, CABINETS, GRAB BARS, ETC. CONTRACTOR SHALL FURNISH 4 INSTALL ALL BACK-UP SUPPORTS 22. DO NOT SCALE DRAWINGS. IF DIMENSIONS ARE IN QUESTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING CLARIFICATION FROM THE OWNER'S REPRESENATIVE BEFORE CONTINUING W/ CONST. 23. CONTRACTOR SHALL VERIFY ALL DIMENSIONS 4 COORDINATE ALL TRADES. 24. CONTRACTOR SHALL VERIFY ALL EQUIPMENT LOCATIONS 4 DIMENSIONS OF EQUIPMENT. 25. REVIEW ALL ELECTRICAL LOCATIONS W/ OWNER BEFORE SIGN OFF FOR DRYWALL. 26. ALL THRESHOLDS 4 FLOOR FINISH CHANGES TO BE PLACED UNDER CENTERLINE OF DOOR UNLESS OTHERWISE NOTED. 21. COORDINATE TELEPHONE 4 SECURITY W/ OWNER BEFORE PROCEEDING. 26. ROOF CONSTRUCTION IS NOT LIGHT FRAME TRUSS 2S, A SEPARATE PERMIT SHALL BE REQUIRED FOR THE FIRE SUPPRESSION SYSTEM 30, ALL INSULATION MATERIALS TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 25 AND A SMOKE -DEVELOPED INDEX OF NOT MORE THAN 450 PER THE FBC 119.2 31. CONCRETE FLOOR SLAB REPLACEMENT SHALL BE 5" GONG. SLAB W/ 6X6-WI.4XW1.4 WWF ON 6 MIL VAPOR BARRIER OVER 12" MIN. CLEAN COMPACTED FILL W/ TERMITE TREATMENT. TIE NEW SLAB INTO EXISTING SLAB/STRUCTURE W/ 03 V-0". EPDXY W/ MIN. 6" EMBED. ROOM IDENTIFICATION DRAWING IDENTIFICATION INTERIOR/CASEWORK ELEVATION IDENTIFICATION SECTION CUT INDICATION PLAN OR SECTION DETAIL INDICATION ROOM NAME FLOOR / LEVEL 201 ROOM NUMBER 2 DRAWING NUMBER SHEET NUMBER DRAWING NUMBER 2-A4 INDICATION OF DIRECTION SHEET NUMBER 3 DRAWING NUMBER INDICATION OF DIRECTION A(o SHEET NUMBER DRAWING NUMBER 3 DETAILED AREA SHEET NUMBER SUPPLEMENTARY DRAWING INDICATION (BOUND IN PROJECT MANUAL). ELEVATION, SECTION CUT, 4 PLAN DETAIL NOTATIONS SIMILAR TO ABOVE 22 DOOR IDENTIFICATION 22 WINDOW/GLAZING IDENTIFICATION O SPECIFIC NOTES O GENERAL NOTES 10. FURNITURE 4/OR EQUIPMENT OFIDENTIFICATION ELEVATION SYMBOL REVISION SYMBOL PARTITION TAG DRAWING NUMBER PAGE NUMBER SEE SCHEDULE SEE SCHEDULE NOTES WHICH APPLY TO SPECIFIC ITEM OR ITEMS ON THE DRUG WHERE INDICATED NOTES WHICH APPLY t0 ALL DRAWINGS SEE SCHEDULE -0FIN FLOOR ELEVATION HEIGHT ELEV 100'-0" SURFACE DESCRIPTION �1 REVISION NUMBER DATE REVISED Al DRAWING NUMBER MATERIAL DESIGNATIONS ELEVATION /FLAN SECTION A� Bill IIIIIIIIIIIIII QCONCRETE/ STUCCO/ GROUT 1=1I I EARTH ROCK ®ONT WOOD BLOCKING w CLASSIFICATION BY OCCUPANCY ASSEMBLY GROUP A-2 MIXED OCCUPANCY NO SEPARATION BY OCCUPANCY NONE TYPE OF CONSTRUCTION PROTECTED HR UNPROTECTED V SPRINKLERED ❑ YES ■ NO BUILDING VARIABLES BUILDING HEIGHT 4 HEIGHT INCREASES NUMBER OF STORIES BUILDING AREA / FLOOR AREA INCREASES OCCUPANT LOAD / FLOOR AREA / PERSON ASSEMBLY TOTAL SEATING / PERSON EGRESS WIDTH / PERSON LENGTH OF DEAD END MAXIMUM DISTANCE TO AN EXIT MINIMUM NUMBER OF EXITS FIRE PROTECTION REQUIREMENTS STRUCTURAL FRAME - INCLUDING COLUMNS, GIRDERS, TRUSSES BEARING WALLS - EXTERIOR INTERIOR NONBEARING WALLS AND PARTITIONS - EXTERIOR >_30 NONBEARING WALLS AND PARTITIONS - INTERIOR FLOOR CONSTRUCTION - INCLUDING SUPPORTING BEAMS 4 JOINTS ROOF CONSTRUCTION - INCLUDING SUPPORTING BEAMS 4 JOINTS REQUIRED 4 ALLOWED 40' 1 " OF FIXED SEATS N/A IST FLR .2 / 16" 20' 200' 2 0 0 0 0 0 0 PROVIDED I-V-2" 1 3,9'113 GSF t + 3511 GSF FREEZER/COOL 80 ERSONS N/A 108" 0' 50' 2 FLORIDA PLUM51NG CODE DATA OCCUPANCY RESTAURANTS FIXTURES WATER CLOSETS URINALS LAVATORIES DRINKING FOUNTAINS REQUIRED 4 ALLOWED PROVIDED MALE/FEMALE MALE/FEMALE 4 3 - 1 2 4 RGD EXTERIORNI UI ATION INSULATION Av �^ v �� TERRAZZO CUT STONE ®METAL (LARGE SCALE) ARCHITECTURAL ABBREVIATIONS IIIIIIIIIIIIIIIIII - ===== LIGHTWEIGHT � GYPSUM BD✓ CONCRETE PLASTER/ STUCCO a :p STRUCTURAL WOOD 8 ° CONCRETE BLOCKING INDEX OF DRAWING6 ARCHITECTURAL CS COVER SHEET ARI AR SHEET DI DEMOLITION PLAN AND NOTES A1.0 FLOOR PLAN AND NOTES A1.1 /D A1.2 PROPOSED SEATING PLAN A13 I T PANS, ELEVATIONS, AND DETAILS AIA N/A A2.0 ELEVATIONS A2.1 ELEVATIONS ELECTRICAL. E1.0 ELECTRICAL LIGHTING PLAN 4 SCHEDULE E2.0 ELECTRICAL POWER PLAN E3.0 ELECTRICAL SCHEDULE E4.0 ELECTRICAL DETAILS KITCHEN EQUIPMENT. K1.0 KITCHEN COVER K2.0 EQUIPMENT PLAN K3.0 EQUIPMENT SCHEDULE NEVIEW DATE: CITY OF ZEPHYRHILLS LU!'I_DING OFFICIAL_ .ALL WORK SHAI ! COMPLY WITH PREVAILING CODES FLORIDA BU LDING CODE.. NATIONAL ELECTRIC CODE, AND THE CITY OF ZFPHyf�HILi S ) i INANCF AFF ABOVE FINISHED FLOOR CI CAST IRON DN DOWN FT FEET PC HANDICAPPED MECH MECHANICAL OD OUTSIDE DIAMETER SCH SCHEDULE TH THRESHOLD ADJ ADJUSTABLE CB CATCH BASIN DWG DRAWING FND FEMININE NAPKIN DISPOSAL HWD HARDWARE MT METAL SNT SEALANT TKBD TACK50ARD AG AIR CONDITIONER CLG CEILING OF DRINKING FOUNTAIN FNV FEMININE NAPKIN VENDOR HT WEIGHT MF METAL FRAME PBML PAPER -BACKED METAL LATH SHT SHEET TPH TOILET PAPER HOLDER ALT ALTERNATE GEM CEMENT FIN FINISH HORIZ HORIZONTAL MRD METAL ROOF DECK PTD PAPER TOWEL DISPENSER SHO SHOWER T 4 G TONGUE 4 GROOVE ALUM ALUMINUM C, CENTERLINE EA EACH FE FIRE EXTINGUISHER MIN MINIMUM PTH PAPER TOWEL HOLDER SHOC SHOWER CONTROLS TB TOWEL BAR AS ANCHOR BOLT CHBD CHALKBOARD E EAST FECR FIRE EXTINGUISHER INCL INCLUDE M MIRROR PLAS PLASTER SHOW SHOWER HEAD TYP TYPICAL UNLESS 4 AND CLO CLOSET ELEC ELECTRICAL CABINET RECESSED ID INSIDE DIAMETER MISC MISCELLANEOUS PLYWD PLYWOOD SIM SIMILAR OTHERWISE NOTED L ANGLE CH COAT HOOK EHD ELECTRIC HAND DRYER FH FIRE HYDRANT MR MOISTURE RESISTANT PT PRESSURE TREATED SD SOAP DISPENSER U URINAL APPROX APPROXIMATELY COL COLUMN EWG ELECTRIC WATER COOLER FL FLOOR Jt JOINT MBH MOP t BROOM HOLDER SH SOAP HOLDER AT CONC CONCRETE ELEV ELEVATION FD FLOOR DRAIN MTD MOUNTED R RADIUS S SOUTH VERT VERTICAL CONST CONSTRUCTION ENCL ENCLOSED / ENCLOSURE FTG FOOTING LAM LAMINATE RPTO RECESSED PAPER SPECS SPECIFICATIONS CONt CONTINUOUS EQ EQUAL FM FRAMED MIRROR LAv LAVATORY N NORTH TOWEL DISPENSER SQ SQUARE WR WASTE RECEPTICAL BD BOARD CONTR CONTRACTOR EQUIP EQUIPMENT NIC NOT IN CONTRACT RECT RECTANGULAR SS STAINLESS STEEL WC WATER CLOSET BM BEAM CJ CONTROL JOINT EXIST EXISTING GALV GALVANIZED MH MAN HOLE NITS NOT TO SALE REINF REINFORCEMENT STD STANDARD WH WATER HEATER BLK BLOCK EJ EXPANSION JOINT GA GAUGE MFR MANFACTURER NO NUMBER REQD REQUIRED STL STEEL W WEST BRK BRICK DTL DETAIL EXP EXPOSED GB GRAB BAR MO MASONRY OPENING RO ROOF DRAIN STR STRUCTURAL W/ WITH ENE CBldRNP E DIA �ODIAMETER EXT EXTERIOR GWB GYPSUM WALLBOARD MATL MATERIAL OC ON CENTER RM ROOM SMS STRUCTURAL METAL W/O WITHOUT DIM DIMENSION EGCB EXTERIOR GYPSUM GYP GYPSUM MAX MAXIMUM OPNG OPENING RO ROUGH OPENING STUD CPT CARPET OR DOOR CEILING BOARD z 0 0 V) w 0 JRz �r ' z I '- c 0 �• U • o 4 c- • s • M� L^. g • .O 3 • • � 3 + U • • �� U. g • o 0- w cc �a am Q �' V U . O N JoO7 OaO O Q •N d nC Q7 N v o .o+COU> pNO> j CD o S a o o-p -0� o� c a a U C O L U 'c NV) "O 0 (U U O �, . N 0 E - c o ).�5vcao N C O O '3 +J p 0 OU OU C� O C S _tc`0�+ _c p O 0 00 0 U, .N U N Q O O CO U O .0.� O (n y U O N N BE U L J~ .0 w O O N v V •O N o N N O 0 0 a_vl .� w CO U V C vOUu u- o o 0 D 0 n 0 � u o �� o0 N U C O N O- 0p 0 .3 O.0 C, O co :3 a)0 0 N 0 7 N (n .0 U Q L > W O .v LO 0 +LO. s H a3 C 0 a p m ? N N $ M w N N (/) o oo N M M 0 0 W N Q O m 0 cr0 � aZ N O Li (n to o 1 p ►0 U U w N ch w Z M N (i pO L) cz � O `� w 0 N w o �$ 0 U Q (n 1802.31 0 z A R 1 tz cn AA-0003276 f o cp 00 a❑ ❑ ❑ �_ --- 1 ❑❑❑o ❑❑❑❑ ❑❑❑❑ ❑❑❑❑ ❑❑❑❑ ! r GENERAL NOTES: I. ALL EXIT DOORS SHAD. BE KEYLESS IN THE DIRECTION OF EGRESS. 2. THE OPENING FORCE OF ALL EXT. PUSH/PULL DOORS SHALL NOT EXCEED 8 IR LBO. 3. THE OPENING FORCE OF ALL INTERIOR PUSH/PULL DOORS SHALL NOT EXCEED 5 LBO. 4. PROVIDE PANIC WARDUI.ARE FOR ALL EXTERIOR DOORS AS NOTED ON THE DOOR SCHEDULE. 5. ALL DOOR HARDWARE SHALL NOT REOUIRE TIGHT GRASPING, TIGHT PINCHING OR TWISTING OF THE WRIST TO OPERATE. DOOR I I. 1 EA CLOSER LCN 4021 x 18 2. 3 EA HINGES OFFSET PIVOT ANSI -A-56A GRADE It PROVIDE EXPOSED PARTS OF CAST ALUMHV ALLOY, AS SUPPLIED BY DOOR MANUFACTURER 3. 1 EA PUSWPULL HANDLE KAWNEER #ICO-9 OR WAGER PUSW/PUL.L SET 164D/V/B. 4. N/A 5. 1 EA THRESHOLD NATIONAL GUARD PRODUCTS, INC. SADDLE TYPE THRESHOLD 325, 36" WIDE x LO" RISE (ADA ACCESSIBLE). 6. 1 EA WEATHER STRIPPING: PROVIDE COMPRESSION WEATHER STRIPPNG AGAINST FIXED STOPS. AT OTHER EDGES PROVIDE SLIDING WEATHER STRIPPING RETAINED IN ADJUSTABLE STRIP MORTISED INTO DOOR EDGE. PROVIDE EPDM OR VINYL GASKET WEATHER STRIPPING IN BOTTOM DOOR RAIL ADJUSTABLE FOR CONTACT W/ THRESHOLD. 1. 1 EA SIGN MOUNT ONTO DOOR, TO READ "TWIS DOOR MUST REMAIN UNLOCKED WHENEVER nQ THE BUILDING IS OCCUPIED/DURNG BUSINESS HOURS." DOOR 90 L� 1. 1 EA HINGE 1W-112HD 83" ALUM WAGER S. I EA TREADPL.ATE 24 X 34 UMCO 2. 1 EA CLOSER 1461 RWA ALUM LCN 9. 1 EA VIEW FRAME L.FRAi 6 X 21 fl/ 3. 1 EA LOCK ND8040D RHO 626 SCWLAGE DKB NGUARD O4. 1 EA ELEC STRIKE 6211 24V DC FOE U0320 SCHLAGE 10.1 EA GLASS 5 X 26 X 1/4 UMCO 5. 1 EA PWR SUPPLY PNM SCHLAGE I1.1 EA GLASS 5 X 26 X 1/4 UMCO O 6. 1 EA DOOR BELL BSV-24P SURFACE MOUNTED Q 1. 3 EA PUSH BUTTON 621-RD-DA HDP 626 SC14LACoE t� I I I ------------� ----------� ■ I I 107 v C1 TL- IG -DPA 61"A.F.F, 0 0 lo, I I I I I I I I I I I I I I I W L CC TO INSTALL ACCESSIBILITY DOOR 6W* WHERE REo= 15Y LOCAL CODES QMANUFACTURING 2. 3. 4. DETEX ALARM CONTACT SWITCHES SHALL DE RECE66M INTO THE TOP OF THE DOOR 4 HOLLOW METAL FRAME ADOVE. DOORS, DOOR FRAMES, . HARDWARE FOR DOORS 3, 3A,15, 6, &A,1, SUPPLIED BY: UNIVERSAL I-800-821-1414. NOT USED W S. 6. SEE ELEVATIONS AND WALL SECTIONS ALL INTERIOR SOLID CORE WOOD DOORS TO HAVE A LAMINATED FINISH, AS INDICATED PER DECOR DWGS U1. SL NOT USED ALL EXTERIOR DOORS SFWLL HAVE MAX I/Z" LEAL CIWM PER MC WWJ6 (� DOOR FRAME MARK MATERIAL SIZE TYPE MATL SIZE n, LL I ALUM. 3'-00xl'-0"xl 3/4" A ALUM. (NOTE (p) O I0 WM 3'-0"x1'-0"xi 3/4" C WM. 20JAM5 411HD Q nw p' OR 1/4" TEMP. _ `v n/ GLAZING Q 1011 STILE _ I Q AT BOTTOM C 1fv'-1 1/2" VERIFY 3 NOTES O i I I , I , I , I , I , w- I------ - - - -1 1/2' 3'-10 1/4" , 000000 0 0 0 0 0 0 ((� I 20'-cJ" NOTE: GENERAL CONTRACTOR SHALL VERIFY ALL SEATING AND DINING DIMENSIONS BEFORE PROCEEDING WITH DECOR INSTALLATION. NOTE: GENERAL CONTRACTOR SHALL INSTALL A POLYETHYLENE BARRIER IN AREAS OF REMODEL WORK THAT REQUIRE DUST PROTECTION. MEANS AND METHODS OF INSTALLING THIS POLYETHYLENE BARRIER SHALL BE PER THE GENERAL CONTRACTOR BASED ON EXISTING FIELD CONDITIONS. z 0 a U w 0 Z 0 c/d I ir w 0 W 0 L1 A fN w M CV 17 Q 0 0 �. N 'm Lm ' •� 4 15 � � �• •�� 5'-011 1 i 4'-81/2"O ----------- �, 3 ❑❑ IF -1 ❑ I I . .Qm M 1 II ��! • H 00 �w J I ------------ L x M I I I W U • on 13 z sn- I 00 a IL �t -. • • -, JJ aU N o-AI3 -o U U O 4)T ���p�o•sZvwN TD D o aa,= N� 70 `- l a -ry I I o .0 --� ° °y' U0.0 ` N� I\p N c cv NE 0 3 •- 2 m .� N a �a O O U -- - 4 C N� OL y•� N N L O C p1 O_ .0 o C L C U a p o j� E m M p C U C O N O 301-011 �� ~ 1� C U U V _c 7 J C w O L7 U�L u C: a N .- C 4)V U) .r...0 � U O N_ N O12 ~ Q E "'�• C O j In :30 y O WALL�+�p0 LE` ENE) O aU 3 c ` o NEW SERVICE POD COUNTER SEE SHEET A1.4 DETAILS. 2 FUTURE BAKED GOODS AREA 3. EXISTING EQUIPMENT 4. FULL HEIGHT WALL EXTENTION 5, KES TO PROVIDE NEW ABS 20 W/ TEA TABLE 6. NEW/RELOCATED HAND SINK. VERIFY WITH KES 1. NEW VALANCE WALL 8 MCCAFE BRTAND PANEL TO BE PLACED ADJACENT TO PICK UP PER USRD STANDARDS 9. ORB MONITOR TO BE CENTERED ON PICK UP COUNTER 10. KES TO PROVIDE NEW 14" X 30" LANDING CART 11. KES TO PROVIDE NEW 45" DIGITAL ASSEMBLY CART W/ FRIDGE 12. KES TO PROVIDE NEW BLZ t FINISHING STATION 13. RELOCATED EXISTING EQUIPMENT 14. NEW EQUIPMENT - VERIFY WITH KES 15. NEW AMENITY STATION 1 FLOOR FLAN 1.0 1/4n_V_0 GENERAL NOTE5 1. EXTERIOR DIMENSIONS ARE TO COLUMN REFERENCE LINES AND/OR FACE OF FOUNDATION WALLS UNLESS NOTED OTHERWISE. 2. INTERIOR DIMENSIONS ARE TO FACE 012 FINISH WALL. 3. DO NOT SCALE DRAWINGS. 4. MINIMUM INTERIOR FINISH CLASSIFICATION: OCCUPANCY A2 NONSPRINKLERED EXIT ENCLOSURES AND EXIT PASSAGEWAYS: A CORRIDORS: A ROOMS AND ENCLOSED SPACES: B 5. GYP BD TO BE USED ON DINING SIDE OF INTERIOR PARTITIONS UNO 6. MATCH EXISTING FINISHES UNO TYP. 1. GC TO REQUEST t FOLLOW ADA REPORT WHEN AVAILABLE 6. AS -GUILTS BASED ON PLANS FROM HtK DALLAS INC. S. SEATING LAYOUT / DIMENSIONS BASED ON PLANS PROVIDED BY ISI 10. ADJUST LOCATION OF KIOSK SO TOP PLATE IS FULLY ON/OR OFF THE SOFFIT (AVOID CEILING CHANGE) Il. NEW FLOOR CEILING AND DECOR, REFER TO DECOR PLANS 12. LOW VOLTAGE WIRING BY OWNER OPERATOR IF REQUIRED UNDER SEPARATE PERMIT TYP. 13. GC TO PROVIDE ADA SIGNAGE PACKAGE AND INSTALL SIGNS AT LOCATIONS AND POSITIONS INDICATED IN PACKAGER OR AS REQUIRED BY LOCAL CODES. SIGNAGE PACKAGE SUPPLIED BY: FORREST DERMA -SIGN, i-800-214-8165 '32'32 1ST ST., BOX 588, NEW ROCHELLE, NY 10802 www.Porrestpermaeigne com lal O O 8 N-0CD0 y a O > fA y U L) EXISTING CONSTRUCTION s � � , 4)L N d ONSTRUCTION NEW CONSTRUCTION----------------- � m ---------------- L---------------- J CONSTRUCTION ABOVE g N L6 z NwN N_ S � 41 W 0 N M LATERAL BRACING TO i �`, i CONT. RUNNER CHANNEL STRUCT. ABOVE i FIRESTOPPING AT EXTENT OF * 4-0" O.G. - Z ,%i BACKUP (TYP) , MTL STUD PARTITION TYPE: N 1/2" GYP BD OR CLG AS ALL PARTITIONS TYPE 'A' < S PLYWOOD BACKUP SCHEDULED UNLESS NOTED OTHERWISE CD m EACH SIDE AS O INDICATED ON FINISH "A" 3 5/8" o SCHED "Al" ■ 3 5/8" W/BATT INS. !� Z Ilpll ■ 611 "BI"■ 6" W/15ATT INS. licit , all "CP - 8" W/BATT INS. W Q O 1 0 fl FLOOR AS STUD SPACING: ib" O.G. : W U SCHEDULED STUD GUAGE: w M LOAD BEARING: I6 i ti s ' ? .• °D •. NON -LOAD BEARING: 20 O 8 z Q U O 04 W �I �o 8 In I 1802.31 2 INTERIOR PARTITION z 1-0 3/41 = V -OII _ 1L/ x 1 6 N AA-0003276 I OLL I- �I �I I ram- J i i p 1 PROPOSED 5EATING PLAN AI-2 1/411 _ 11 _O11 An SEATING RATIO NUMBER OF SEATS SO SEATS HANDICAPPED SEATS REQUIRED 4 C� HAND ICAPPED SEATS PROVIDED 4 NOTE: THIS DRAWING IS 8A5ED ON THE DIMENSIONAL INFORMATION PROVIDED BY ISI, 8,4SED ON THEIR FIELD VERIFICATIONS. CONTRACTOR TO VERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTION. I z 0 U V) W 0 Z 0 Ln Q' 0 W 0 16 W W o o L —• • M • 0 a • O 3 • • � 3 4) 4-0 • _ 00 ti uo � l y • Vl M z" M am • <c • • M (L • . 0 a) p v L) J o v a> ° N'F o ° O v L-vc +� Q •� a a p 0� U .L a Q1 N 6> 0 O a )D O v a o 2 " 'o a.c'o c 6"ai 0(y0E� o �� o a .0 aU)o Qc r2 N N U C a) 173.0 0 N a a) C� �'-- C O INL0Cp, O U a p U C L —_++ c:Oar L O p o O p C N + C C �- to p -�0.� N U o C 0 c 0. °3 0 p 0— y c O O J C 0 0 0:3 N O O y O )� c,ccC N .N �E 0 4 U C O Q O N T a) E � p �av,�E 0 7 N O y 7 p p om•. ao o,mc o-av O to ;-ftLl-cap•3 -mo o O;°p o opo.� ® rz N a 0 > to 0 U U L O Q 2 4)I- 0 a3 ° c aim a. aP=J N Lr; T N r 00 M M N m I Q! Z o O U LLJ U U� W = N M Q Z Q C U O W J G pi L O U S 1802.31 0 rz A 1 2 cn AA-0003276 .. M 1-5/8" UNISTRUT 12" O.0 2 ROWS STAGGERED ATTACHED TO BOTTOM CHORD OF ROOF JOIST (2 MIN.) 1-5/8" UNISTRUT ATTACHED TO 1-5/8" UNISTRUT POST BASE. CONNECT TUBE STEEL BRACKET TO PLYWOOD WITH (4) 1/4 ZING 1" BOLTS. 3/4" PLYWOOD BACKING CEILING AS SCHEDULED - CP CURATED PANEL MOUNT PROVIDED TO GC, BY S4D VENDOR 15 CUi�ATED PANEL INSTALL DETAIL I" VENT HOLE 0 6" O.G. W 6 MTL $TUC ON 3/4" Ar PLYWOOD A I —FP DIGITAL MENU BOARD PEERLESS SMARTMOUNT PORTRAIT WALL MOUNT. INSTALL PER MANUFACTURER'S REQUIREMENTS. LOCATE CENTERED WITHIN NICHE GL RECESSED 4XI2 LOUVER. GC TO PROVIDE (1) LOUVER PER DMB. CENTER AROUND STUD SPACING. A ON 3/4" Al PLYWOOD A 6 MTL STUI MTL STUDS ® 16" 11 -SECTf ON 1"IERG1-SAND ISER 1.5 I" 2 I'-0" QAl it r/AII z w &A15 URATED VIEW PANEL KENr NOTE5 CORNER GUARD: 3/4" ANGLE BY DECOR x— COLOR: A = BLACK ® CORIAN: x— COLOR: A = CORIAN CAMEO WHITE BY GC B = CORIAN DEEP TITANIUM BY GC I� F.R.P. OVER 1/2" PLYWO. —' EXTEND 6" ABOVE CLG. LINE RECESSED FENDER WASHER IT 6" VERT. STRUT * 16"OC W/ 1/2" THREADED ROD 4'-0"OC CEILING AS SCHEDULED NEW VALANCE - ALIGN WITH NEW DIGITAL MENU BOARD WALL NEW TILE OVER V" CEMENT BOARD CONT. (2) 2x6 PLATE 14 VALANCE SECTION L A PERFORATED PANEL t SUPPORTS BY DECOR ON 3/4" PLYWOOD Ai BEHIND BRACKET A MTL STUDS 0 16" O.G. AT RECESS PEERLESS SMARTMOUNT PORTRAIT WALL MOUNT. INSTALL PER MANUFACTURER'S REQUIREMENTS. LOCATE CENTERED WITHIN NICHE DIGITAL BOARD 6 MTL STUD STUD PARTITION FP •► 10 PLAN MERCHANDISER ISER 0 p 4'-01/4" Z 1 F T1 T1 - aIhl _NTER 15LANO 4'-011 CURATED VIEW PANEL A1.5 1/4-1 = 1'-01' z F m r N MONI BRAC CLIP: ACCES& SY8 FA o u ORDER READY BOARD (ORB) WALL BRACKET ACCESSORY SYSTEM WITH LEVELING CONTROL li�; '� I I�I����u1111� • SECURE TO STUDS OR 3/4" PLYWOOD BACKING • FOLLOW MANUFACTURER'S INSTALLATION INSTRUCTIONS g NOT USED 41.5 1 = r-011 4RRY TILE COVE SE r: SCHLUTER EX-AI-K 5 KITCHEN ELEVATION A1.5 1/4,, = 1'-0" SWALL TILE: CROSSVILLE - COLOR BY NUMBERS COLOR: INTUITIVE GRAY. SIZE: 4"x12", PATTERN: RUNNING B BOND GROUT: MAPEI 02 PEWTER - JOINT TO BE X6" MAX. USE THIS TILE WHEN HIGH LRV IS REQUIRED COORDINATE WITH THE McDONALD'S AREA CONSTRUCTION MANAGER FIBERGLASS REINFORCED PLASTIC (FRP) - PANOLAM, GRAY SMOOTH, CLASS C, .0'15. REFER TO ROOM FINISH SCHEDULE SHEET A6.1 FOR INSTALLATION LOCATIONS. FOR ORDERING, CONTACT KIMBERLY LAWSON KImberV/,/Lawson*panolamzom 1-866-525-431-1 T I FRONT COUNTER ------ ---,� FURNISHED t INSTALLED I BY DECOR I II VENDOR Q I I N I II N I II I I II II J� F REMOVABLE LAMINATE KICK PLATE QUARRY DINING ROOM TILE TILE 12 SECTION -SERVICE POD g NOT USED 41.5 1" , I'-0" ORDER READY BOARD. CENTER BETWEEN COUNTER 13 AND F/ McCAFE WALL A1' PICK-UP COUNTERt B CP DECAL 4 SERVICE AREA ELEVATION A1.5 1/4" = 1'-0" LAMINATE: ® x— COLOR: A = IDMB / DIG. MERCH., SMOOTH BLACK PLASTIC LAMINATE BY GC B = TRASH/ COND., WHITE PLASTIC LAMINATE BY GC C = TRASH/ COND., LAMITECH GRAPHITE K MATTE FINISH BY GC D SEE DECOR DRAWINGS. MFR BY DECOR. PURCHASE AND INSTALL BY GC E = McDELVIERY UNDERSCORE, LAMITECH GOLDEN F BASE BOARD, FORMICA COMPACT LAMINATE MATTE BLACK BY GC DE McDELIVERY OR PICKUP DECAL BY GC ORDER FROM ANN BOWEN WITH VOMELA: ann.bowenevomela.com SERVICE POD OUTLINE KNEE WALL BY GC F QUARRY TILE COVE BASE ALT: SCHLUTER DILEX-AHK (j)= FRONT COUNTER PLAN 1/2° - 11-0" DIA PLAYER TALLED BEHIND REENt REFER TO NUF. INSTRUCTIONS BY GC ;K-UP )UNTERt BY CP 3 PICKUP AREA ELEVATION A1.5 GENERAL NOTE5 • ALL WALL LAMINATE PANELING MANUFACTURED BY DECOR PURCHASE AND INSTALL BY GC UNO • AtE TO VERIFY LOCATION AND QUANTITY OF LIGHTS AND DIFFUSERS AFTER SERVICE AREA WALL ADDITION e•'� A.11-1 DV �P"/ri1e9 OF COUNTERTOP AF.F.) 4R FRONT COUNTER 4ED 4 INSTALLED JP COUNTER C MET. PANEL t E c BY GC F 2 -SERVICE AREA ELEVATION A1.5 1/4" = 1' 1 ENTIRE SHEET CHANGED z O CL w U N w z 0 O 0 w 0 16 w V) w N M Q O r _ � h 0 Ort � M • 3 � , w a v Q.� . . > g w a � • o� � zM a . . w U + ° 0 U pC N.=O V wcanvv�V v c � o_ O - L ND N O to a„ C O `o N a U a o o a� -� � � 0 E•a�� c o o a Q N V C N cu U N N N =°�°'o N COa� L1°iE C L V .0 p OC •pi a C 0 UO V p C L U C p U N a v • c c cn o � � E v C p C U'0 p 0 0 O O p p O 7: N (/) U L _ N � ~ ° —J •� ..0.. 0 N L =0.°mvCin° O u � .w C a c u - rn .� ;' N 0 - ° L C �a pram TE O C c ch :3 :3 Qp p O° to O N p 0 o lcf m " ti u' Cv' a 030.0opv p o� w —��°�o o a�a�m�u° s o om�a) o t— a3 C- cn- a �p m ? N N o Lo M 0 0 _J r }x 2 w w N Q o m o 0 o sZ J N N 0 LJ I Z O 0 W 0 N w Qn Z M o N 5 Oa Q a n w �< c�i o a 0 :2�' 0 o 0 g to 1802.31 0 Z A 1 5 m V) AA-0003276 LIGHTING FIXTURES MANUAL SWITCH (if shown on drawings) LOW VOLTAGE CABLE MOTES: 1. REFER TO LIGHTING PLAN FOR OCCUPANCY SENSOR LOCATIONS AND QUANTITIES. OCCUPANCY SENSOR CONTROL DETAIL LIGHTING FIXTURE SCHEDULE NOTES: 1. ORDER LED EXIT SIGNS WITH LETTER COLORS THAT COMPLY WITH LOCAL CODES FROM SECURITY LIGHTING. FOR RED LETTERS USE #PRB (UNIVERSAL) FOR GREEN LETTERS USE #PGB (UNIVERSAL) OR IF THE ABOVE EXIT SIGNS DO NOT COMPLY WITH LOCAL CODES USE, LED SIGN WITH BATTERY BACKUP, LETTER SIZE, COLOR, TYPE AND DIRECTIONAL ARROWS AS REQUIRED BY THE LOCAL AUTHORITIES. 2. BEFORE ORDERING VERIFY WITH LOCAL MUNICIPALITY THAT THIS FIXTURE COMPLIES WITH ANY LOCAL LIGHTING ORDINANCE. EMERGENCY LIGHTING NOTES: CONNECT ALL EXIT SIGNS, EMERGENCY LIGHTS, INVERTER AND NIGHT LIGHTS TO THE EXISTING EXIT/EMERGENCY LIGHTING CIRCUIT. 2. CONNECT ALL EXIT SIGNS, EMERGENCY LIGHTS AND NIGHT LIGHTS TO ONE CIRCUIT BREAKER. 3. LIGHTING INDICATED WITH A "NL" ARE NIGHTLIGHTS AND SHALL BE CONNECTED TO THE UNSWITCHED LEG OF THE CIRCUIT. 4. EMERGENCY LIGHTING HAS BEEN DESIGNED PER NFPA 101 MAINTAIN 1 FC IN PATH OF EGRESS. IF FIELD CONDITIONS REQUIRE ANY CHANGES TO LIGHTING DESIGN, EMERGENCY LIGHTING, SHALL BE INSTALLED TO MEET THE ABOVE REQUIREMENTS. LIGHTING FIXTURE SCHEDULE SYMBOL DESCRIPTION MANUFACTURES CAT. NO. VOLTAGE LAMPS MOUNTING A LED DOWN RADIUS WALL SCONCE - SILVER FINISH SECURITY LIGHTING SYSTEMS NO.: RWSC-36LED-5K-DO-U-PS 120 14W WALL MOUNT E WALL WASHER SECURITY LIGHTING SYSTEMS NO.: RDA-00LM30-NF-S/RDA-60-H 120 16 CEILING RECESSED SEE LIGHTING FIXTURE SCHEDULE NOTE NO.2 LED CAN LIGHT SECURITY LIGHTING SYSTEMS NO.: 12W CEILING RECESSED F BLUE ROUND PENDANT SECURITY LIGHTING SYSTEMS NO.: 12 PENDANT HUNG B 0 RDA-136LM-30-FL-S/RDA-136-H 120 7652 BLE-EQL-306-45358-1-LED 120 REFER TO DECOR DRAWINGS FOR EXACT FIXTURE TYPE LED CAN LIGHT FED FROM SECURITY LIGHTING SYSTEMS NO.: 12W CEILING RECESSED G SLIM PENDANT GREY LARGE SECURITY LIGHTING SYSTEMS NO.: 20 CEILING RECESSED BE O UNSWITCHED INVERTER PANEL FOR USE AS NIGHT LIGHT AND RDA-136LM-30-FL-S/RDA-136-H 120 6797-BPS-1388-71 REFER TO DECOR DRAWINGS FOR EXACT FIXTURE 120 NL EMERGENCY LIGHT. TYPE 2x4, LED LAY -IN PRISMATIC SECURITY LIGHTING SYSTEMS NO.: 44W CEILING LAY -IN C ACRYLIC LENS LCAT24-35HLG-EDU-WP-GK 120 COMBO WITH BATTERY BACK-UP 120 UNIT 20, LED LAY -IN PRISMATIC ACRYLIC SECURITY LIGHTING SYSTEMS NO.: 44W CEILING LAY -IN EMERGENCY BATTERY AND DUAL LITE 2-5W SURFACE TO WALL CE LENS FED FROM UNSWITCHED LCAT24-35HLG-EDU-WP-GK 120 X 2 REMOTE HEAD EV4D-02L-0/EVODB 120 OR SOFFIT INVERTER PANEL FOR USE AS NIGH WHEN CONNECTED TO TWO REMOTE HEADS NL LIGHT AND EMERGENCY LIGHT. (I= (FOR SINGLE GANG JUNCTION BOX) DELIVERY POD LED LIGHT SECURITY LIGHTING SYSTEMS NO.: 9W CEILING RECESSED DENOTES EXISTING DEVICE TO DP 0 LB4-6LD-30K-9-GD/IBX4QL-120 120 EX REMAIN (PROVIDED WITH DELIVERY POD) D 2 HEAD DOUBLE GIMBALL SECURITY LIGHTING SYSTEMS NO.: 14 CEILING RECESSED CEILING -MOUNTED LIGHTING INVERTER WITH MAINTENANCE FREE SEALED (MULTIPLE 25 DEGREE) GM2-120-LM-30-SBS 120 O LEAD CALCIUM BATTERY. Co REFER TO DECOR DRAWINGS FOR EXACT FIXTURE SECURITY LIGHTING SYSTEMS LG1 SERIES TYPE INVERTER MAXIMUM OF FOUR 12.5 WATT CAN LIGHTS PER INVERTER DE 2 HEAD DOUBLE GIMBALL FED FROM SECURITY LIGHTING SYSTEMS NO.: 14 CEILING RECESSED m UNSWITCHED LIGHTING CIRCUIT GM2-120-LM-30-SBS 120 FOR USE AS NIGHT LIGHT AND REFER TO DECOR DRAWINGS FOR EXACT FIXTURE NL EMERGENCY LIGHT TYPE u REVIEW DATE: CITY OF ZEPHY__&__' µ_ RHILLS BUILDING OFFICIAL___ GENERAL NOTES EC SHALL FIELD VERIFY THAT ALL LIGHT FIXTURES SHOWN ON THIS PLAN DO NOT OBSTRUCT OR CONFLICT WITH THE WORK OF OTHER TRADES. IF A DISCREPANCY IS FOUND, THE EC SHALL IMMEDIATELY NOTIFY THE GC BEFORE THE INSTALLATION OF SUCH FIXTURE(S).. IF PC-POS CASH REGISTER SYSTEM IS INSTALLED, RELOCATE FIXTURES ABOVE FRONT COUNTER TO AVOID GLARE ON THE CASH REGISTER SCREENS. INSTALL CABLE WHIP TO FIXTURES SO THAT FIXTURE CAN BE RELOCATED FOUR FEET WITHOUT DISCONNECTING CABLE WHIP. 3. THE USE OF "MC" CABLE WHERE PERMITTED BY LOCAL CODES WILL BE ALLOWED FOR ALL WIRING TO THE LIGHT FIXTURES. "ROMEX" & "BX" ARE NOT ACCEPTABLE. 4. LIGHTING FIXTURES AND LAMPS HAVE BEEN CHOSEN TO ACHIEVE MAXIMUM ENERGY CONSERVATION WHILE MAINTAINING ADEQUATE LEVELS OF ILLUMINATION. LAMP SPECIFICATIONS MUST BE STRICTLY FOLLOWED. ANY DEVIATION FROM LAMP SPECIFICATIONS MUST BE APPROVED IN WRITING BY McDONALD'S CORPORATION. 5. ALL BRANCH CIRCUIT WIRING TO 120 VOLT LIGHTING FIXTURES AND RECEPTACLES SHALL BE AS FOLLOWS. MAXIMUM LENGTH 85FT. - 2 #12, 1 #12 E.G. MAXIMUM LENGTH 140FT. .2 #10, 1 #10 E.G. MAXIMUM LENGTH 225FT. - 2 #8, 1 #8 E.G. MAXIMUM LENGTH 350FT. - 2 #6, 1 #6 E.G. 6. ALL EXTERIOR J-BOXES AND RECEPTACLES SHOWN ON THIS PLAN SHALL BE WATERPROOF. IF SIGNAGE DOES NOT COME WITH DISCONNECT SWITCH PROVIDE TOGGLE SWITCH WITH WEATHERPROOF COVER. ORDER ALL LIGHT FIXTURES FROM: SECURITY LIGHTING SYSTEMS, INC. PHONE: 1-800-LIGHT-IT EMAIL: QUOTATIONS�SECURITYLIGHTING.COM NOTE: VERIFY LIGHTING FIXTURE CATALOGUE NUMBERS WITH INTERIOR DESIGNER PRIOR TO ORDERING FIXTURES. 1 WPi 9 J-BOX FOR McDONALDS FASADE SIGN O KEYNOTE -LEGEND._____ Y 1. CONNECT TO EXISTING CUSTOMER SERVICE LIGHTING CIRCUIT SERVING THIS AREA. 2. CONNECT TO EXISTING DINING AREA LIGHTING CIRCUIT SERVING THIS AREA. 3. CONNECT TO THE EXISTING EXIT/EMERGENCY/NIGHT LIGHTING CIRCUIT. 4. EXISTING LIGHTING AND EMERGENCY LIGHTING IN THIS ARE TO REMAIN AS IS. 5. CONNECT TO EXISTING TOILET LIGHTING CIRCUIT THAT WAS MADE SPARE BY DEMOLITION. 6. PROVIDE CEILING MOUNTED ULTRASONIC OCCUPANCY SENSOR IN RESTROOMS (HUBBELL ATU500C). AIM SENSOR IN DIRECTION INDICATED BY ARROW FOR MAXIMUM COVERAGE OF ROOM. REFER TO OCCUPANCY SENSOR DETAIL ON THIS SHEET. ORDER ALL OCCUPANCY SENSORS FROM, SECURITY LIGHTING LIGHTING SYSTEMS, INC. 7. EACH RESTROOM HAS ONE SENSORS THAT CONTROL ALL LIGHTS TOGETHER AT ONCE IN RESPECTIVE RESTROOM. 8. CONNECT TO UNSWITCHED LEG OF THE RESTROOM LIGHTING CIRCUIT TO FEED INVERTER. 9. CONNECT TO EXISTING KITCHEN/SUPPORT AREA LIGHTING CIRCUIT SERVING THIS AREA. 10. CONNECT TO EXISTING PHOTOCELL EXTERIOR SECURITY LIGHTING CIRCUIT. 11. EC SHALL INSTALL AND CONFIGURE REMOTE EMERGENCY LIGHTING AT AL L EGRESS EXTERIOR DOORS FOR MAXIMUM ILLUMINATION AT POINTS OF EGRESS. INS'TALL WP J-BOX WITH IN SOFFIT TO ALLOW A FLUSH INSTALLATION OF ANY EXTERIOR EMERGENCY EGRESS LIGHTING (TYPICAL). 12. CONNECT TO EXISTING EXTERIOR LIGHTING WALL SCONCE CIRCUIT. \ 13. REFER TO ARCHITECTURAL ELEVATIONS FOR HEIGHTS AND LOCATIONS OF WALL SCONCE AND CANOPY DOWNLIGHTS. 14. EXISTING FRONT FASADE SIGN CIRCUIT. LOAD SUMMARY NO ADDITIONAL LOAD ADDED. LOADS ADDED ARE OFFSET BY LOADS REMOVED BY DEMOLITION. mkiI M N O ' a O � L • ay + U' ' w L < � R 9 9 0 0 x a. _ J Ld a O Lv r' THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY ADAM T. EMERALD ���� 180 2.31 POWELL, PE USING A DIGITAL SIGNATURE AND DATE. PRINTED COPIES ENGINEERING I N IM OF THIS DOCUMENT ARE NOT E 1 CONSIDERED SIGNED AND SEALED AND 9942 CURRIE DAVIS DR. STE H., TAMPA, FL 33619 THE SIGNATURE MUST BE VERIFIED ON TEL (813) 995-0300 !jl .0 ANY ELECTRONIC COPIES. WWW.EMERALDMEP.COM EEI PROJECT* 22072M 88jj - -------- I EXISTING PANEL AP4 I E ISTING E ECTRICAL M P, AP1, AP2 D AP3 6-7 I V-7 I i i li i�I I� GENERAL NOTES: 1. ALL WORK SHALL BE IN ACCORDANCE WITH THE 2017 NATIONAL ELECTRICAL CODE AND SHALL ALSO COMPLY WITH ALL APPLICABLE RULES AND REGULATIONS OF LOCAL AND STATE LAWS AND ORDINANCES. 2. CONTRACTOR SHALL MAKE A THOROUGH EXAMINATION OF THE SITE AND THE CONTRACT DOCUMENTS. NO CLAIM FOR EXTRA COMPENSATION WILL BE RECOGNIZED IF DIFFICULTIES ARE ENCOUNTERED WHICH AN EXAMINATION OF SITE CONDITIONS AND CONTRACT DOCUMENTS PRIOR TO EXECUTING CONTRACT WOULD HAVE REVEALED. 3. ELECTRICAL CONTRACTOR SHALL ARRANGE FOR ALL NECESSARY PERMITS, LICENSES, UTILITY COORDINATION AND INSPECTIONS AS REQUIRED BY THE CITY OR UTILITY COMPANY. OWNER WILL PAY FEES. CONTRACTOR IS RESPONSIBLE FOR ALL EQUIPMENT REQUIRED BY UTILITY COMPANY AND SHOULD INCLUDE NECESSARY COSTS IN BID. 4. CONTRACTOR SHALL LEGIBLY MARK-UP A SET OF 24"x36" DRAWINGS TO REFLECT AS -BUILT CONDITIONS AND TURN OVER TO THE ARCHITECT. 5. PANELBOARD MANUFACTURER SHALL PROVIDE ARC -FLASH WARNING LABELES FOR MDP AND ALL BRANCH PANELBOARDS IN ACCORDANCE WITH NEC 110. GROUNDING: 1. THE INTERIOR ELECTRICAL SYSTEMS SHALL BE COMPLETELY AND EFFECTIVELY GROUNDED AS REQUIRED BY NATIONAL ELECTRICAL CODE ALL METALLIC RACEWAYS SHALL BE MECHANICALLY AND ELECTRICALLY SECURE AT ALL JOINTS AND AT ALL BOXES, CABINETS, FITTINGS AND EQUIPMENT. OUTLET BOXES/DEVICES: 1. ALL OUTLET BOXES SHALL BE RIGIDLY MOUNTED AND SHALL BE EQUIPPED WITH SUITABLE SCREW FASTENED COVERS. OPEN KNOCKOUTS OR HOLES IN BOXES SHALL BE PLUGGED WITH SUITABLE BLANKING DEVICE. 2. OUTLET BOXES SHALL BE 4 INCH SQUARE x 2-1/8" DEEP. OUTLET BOXES LOCATED ABOVE THE CEILING SHALL BE LEGIBLY IDENTIFIED WITH BRANCH CIRCUIT NUMBER OF CIRCUIT TERMINATED WITHIN BY MEANS OF BLACK PERMANENT MARKER. SWITCHGEAR: 1. PANELBOARD DIRECTORY CARDS SHALL BE TYPEWRITTEN WITH ACCURATE AND CURRENT INFORMATION BY THE CONTRACTOR AT THE END OF CONSTRUCTION. __..._._ _ . TP AP4-40 I � O s i I j1_.- I] II I i � f i j TP �....._..... 6 6 AP1-13 6 I , 8207.09 E 1 - 215.07 1 E1 ; � E ?I JEW EXISTING I i PANEL LP WIRE/RACEWAY: 1. ALL CONDUCTORS SHALL BE COPPER, CONDUCTOR INSULATION SHALL BE DUAL TYPE THHN/THWN 75°C. (167°F) FOR DRY, DAMP, AND WET LOCATIONS. CONDUCTOR INSULATION WITH SINGLE TYPE MARKING THHN 90°C (194°F) MAY BE USED FOR DRY LOCATIONS ONLY. ALL CONDUCTORS SHALL BE COLOR CODED AS REQUIRED BY NEC AND FURTHER IDENTIFIED AND CODED AS SPECIFIED HEREINAFTER. COLOR CODING SHALL BE BY MEANS OF COLORED INSULATING MATERIAL, COLORED BRAID OR JACKET OVER THE INSULATION OR BY MEANS OF SUITABLE COLORED, PERMANENT, NON -AGING, INSULATING TAPE APPLIED TO CONDUCTORS AT EACH CABINET OR JUNCTION POINT. THE COLOR CODING SHALL BE ACCOMPLISHED AS THE CONDUCTORS ARE INSTALLED. THE FOLLOWING SYSTEMS OF COLOR CODING SHALL BE STRICTLY ADHERED TO: A) GROUND LEADS: GREEN B) 120/208 VOLT UNGROUNDED PHASE WIRES: PHASE A: BLACK PHASE B: RED PHASE C: BLUE NEUTRAL: WHITE THE COLOR CODE ASSIGNED TO EACH PHASE WIRE SHALL BE CONSISTENTLY FOLLOWED THROUGHOUT 2. ALL BRANCH CIRCUIT WIRING TO 120 VOLT LIGHTING FIXTURES AND RECEPTACLES SHALL BE AS FOLLOWS. MAXIMUM LENGTH 85FT. - 2 #12, 1 #12 E.G. MAXIMUM LENGTH 140FT. - 2 #10, 1 #10 E.G. MAXIMUM LENGTH 225FT. - 2 #8, 1 #8 E.G. MAXIMUM LENGTH 350FT. - 2 #6, 1 #6 E.G. 3. UNLESS OTHERWISE NOTED ALL CONDUCTORS SHALL BE RUN IN THIN WALL CONDUIT AND THIN WALL CONDUIT SHALL BE UNDERWRITERS' APPROVED GALVANIZED ELECTRICAL METALLIC TUBING. COUPLINGS AND CONNECTORS SHALL BE STEEL SET -SCREW TYPE, ZINC OR CADMIUM PLATED. MC CABLE MAY BE USED WHERE CONCEALED IN WALLS. 4. ALL RACEWAYS SHALL BE PROPERLY ALIGNED, GROUPED, AND SUPPORTED BY MECHANICAL TYPE 'CADDY CLIPS AT INTERVALS NOT EXCEEDING 8 FEET. 5. ALL RACEWAYS WITH NO. 10 OR 12 AWG PHASE CONDUCTORS FOR RECEPTACLES, LIGHTING FIXTURES AND SIMILAR CIRCUITS SHALL BE PROVIDE WITH A PARITY SIZED GREEN EQUIPMENT GROUND CONDUCTOR. GROUND CONDUCTOR SHALL BE INSTALLED IN ENTIRE RACEWAY SYSTEM INCLUDING WALL SWITCHES AND FLEXIBLE CONDUIT TO LIGHT FIXTURES. EQUIPMENT GROUND CONDUCTOR SIZES FOR CIRCUITS WITH PHASE CONDUCTORS LARGER THAN NO. 12 AWG ARE INDICATED ON DRAWINGS. GROUND CONDUCTORS SHALL BE CONNECTED TO GROUND BUSS IN PANELBOARDS. 6. RACEWAY PENETRATIONS OF FIRE RATED WALLS AND/OR FLOORS SHALL BE SEALED TO MAINTAIN INTEGRITY OF CONSTRUCTION. ALL PRODUCTS, MATERIALS AND METHODS OF INSTALLATION SHALL BE UL APPROVED AND MEET NFPA. 7. ALL ELECTRICAL CONDUITS SHALL BE CONCEALED IN WALLS UNLESS AS -BUILT CONDITIONS PROHIBITS. GC TO NOTIFY ARCH/ACM OF AS -BUILT CONDITIONS. 004.20 E7 1� i I 039.15 E3 041.09 1 E1 j 216.00 E2 ------- 216.00 216.00 E3 213.00 E11 7 R�, , POWER PLAN SCALE: 1/4" = V-0" TP 210.00 E10 �215.00�lEl210 TP TP TP 0 O U o f yWy I W i Nri w r s /mow luj `.� It � .. •.- re f I vsr (3 . B I X8021.11 E1 8181.01 E2 E2 8203.02 E2 ( L El 8205.11 E2 3 E2 8216.00 E2 E2 8216.00 E7) E2 Lm _ 207.09 E 1 207.10 1 E1 - e `g 8025.02 E2 8039.09 E 1 i ram- _ -_ � �"` 1 I � ; �\ � E • 3 009.15 E1 8023.05 E2 8216.00 1 E2- a o 216.00 E2 8023.05 E2 8216.00 E7 > 246. E7 8024.01 E1ju 8217.13 E2 © � 217.00 E`t� - 8215. 8 E1 8219.00 E7 ca 3021.Q1 E2 8215.98 2 -821 E8 W21.98 82 �5 9 E2 7000.12 --- __ I _ ..._10 oil O KEYNOTE LEGEND 1. RACEWAY KIT PROVIDED WITH COUNTER, INSTALLED BY EC. a 2. IF OPTIONAL TABLE TRACKER SYSTEM IS TO BE USED. IF USED, PROVIDE 2 #12 AND 1 #12 GROUND TO AVAILABLE SPARE 20A/1 P BREAKER. CONNECT CIRCUIT TO (3) 5-20R RECEPTACLES, (1) RECEPTACLE FOR MODEM/GATEWAY (TYPICALLY LOCATED BEHIND VALENCE AT 7'-9" AFF), (1) RECEPTACLE FOR LOCATOR CHARGER (TYPICALLY LOCATED IN MANAGERS OFFICE) AND (1) RECEPTACLE FOR MONITOR (TYPICALLY LOCATED AT PICKUP COUNTER). COORDINATE EXACT LOCATION(S) IN THE FIELD. 3. COORDINATE LOCATION AND REQUIREMENTS OF HAPPY MEAL DISPLAY WITH DECOR COMPANY. TIE INTO LIGHTING CIRCUIT SERVING THIS AREA, 2 #12 AND 1 #12 E.G. IN 1/2' CONDUIT. 4. RELOCATED ORDERING KIOSK. COORDINATE EXACT LOCATION AND REQUIREMENTS WITH ARCHITECT AND OWNER PRIOR TO RELOCATIONS. EXTEND CIRCUITRY AND CONDUCTOR AS REQUIRED. VERIFY THAT EACH KIOSK IS POWERED BY A 1 POLE 20 AMP CIRCUIT BREAKER. 5. COORDINATE LOCATION AND REQUIREMENTS OF FUTURE CASH HANDLER WITH O 0 DECOR COMPANY. POWER IS FED FROM ORDERING KIOSK BASE PLATE, IF NOT LOCATED NEXT TO THE WALL. IF LOCATED NEXT TO TO A WALL THEN FEED FROM Q. _ WALL POWER. 6. COORDINATE LOCATION AND REQUIREMENTS OF J-BOX FOR DECOR ELEMENT WITH DECOR DRAWINGS. 2 #12 AND 1 #12 E.G. IN 1/2' CONDUIT. 7. CONNECT TO SPARE 20 AMP - 1 P, 120 VOLT BREAKER. FURNISH AND INSTALL BREAKER IF A SPARE IS NOT AVAILABLE. CONTRACTOR TO FIELD VERIFY CIRCUIT NUMBERS AND EXACT NUMBER OF SPARES AVAILABLE. SEE SHEET E3.0 FOR REQUIREMENTS THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY ADAM T. _ ���� POWELL, PE USING A DIGITAL SIGNATURE AND DATE. PRINTED COPIES ENGINEERING I N r OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND I DAVIS E 9942 CURRIDR. STE H., TAMPA, FL 33619 THE SIGNATURE MUST BE VERIFIED ON TEL (gU) ANY ELECTRONIC COPIES. WWW.EMERALDMEP.COM EEI PROJECT* 22072M .J 11 W 0 O m Ld cr 1802.31 E 2. 0 LOAD SUMMARY EXISTING MDP (1000 AMP MAIN BREAKER) EXISTING LOAD @ 125% PER NEC 220.87 180,500 VA NEW ADDITIONAL LOAD 16,512 VA NEW TOTAL 197,012 VA (547 AMPS) EXISTING PANEL "AP4" SQUARE D: NQ 208Y/120V, 30, 4W VOLTAGE/PHASE 200A MLO 200A BUS NEMA-1 SURFACE CKT AMPS POLE 2 20 1 4 20 1 6 20 1 1 SERIES RATED DESCRIPTION COPPER BUS SOLID NEUTRAL CKT AMPS POLE DESCRIPTION NOTES L� NOTES LOAAD 600 1200 1 3 20 20 1 EX REFRIG COUNTER X SILVER KING 720 EX ASS 1 960 EX SMDTHEE 5 1 20 1 EX ASS IN CHASE 600 _- EX CU MACHINE 7 30 2 EX SPECIALTY COFFEE 2246 8 20 1 EX INDOOR DIRECT 900 9 2246 10 20 1 3 1 EX RTI OUTLETS 900 1813 11 13 20 1 EX SAFE _ ._ _--- EX TEA BREWER 120 12 14 30 EX TOASTER EX TIME CLOCK 30 2 2246 1813 15 2246 2246 16 1813 17 19 21 30 --- 20 2 EX LOAD X PRINTER 18 20 120 1602 2246 20 - 1 22 30 2 1 EX C!ING OVEN 1 1000 1602 23 20 1 EX DIT 2 300 24 30 30 2 EX VIPER EX LOAD Q'ING OVEN Q'INGOVEN 1487 25 20 1 1 EX D/f 1 1 300 26 1487 27 29 31 20 - BAKED_GOODS/DCO 360 1356 768 28 2 2 2 _ t,2 1487 1487 1602 20 1 _- REACH -IN REFRIG 1,2 1,2 30 20 - 20 1 - 1 BASE REFRIGERATOR 32 - - - 34 20 33 35 FINISHING STATION - 1,2 960 528 1602 1602 20 1 CASH RECYCLER 1 36 20 1,2 37 20 1 DELIVERY TABLETS 1 720 39 20 1 KVS/POS/STICKY LABEL_ 1 1 40 20 1 DINING RECEPTACLES _ 1 720 184 42 20 1 DINING RECEPTACLES_ -_1 9DO LOAD C EC D MA D DESCRI ON OA0 (VA)' FA (VA) UGHT1NG 00.00 0 HVAC - COOL 0 0.00 0 HVAC - HEAT 0 0.00 0 RECEPTACLE 10,372 0.98 10,186 MISC 42,527 1.00 42,527 TOTAL 52,899 52,713 41 20 1 _ HOT WATER DISPENSER _ 1,2 NOTES: 1- NEW BREAKER TO MATCH TYPE AND AIC RATING OF EXISTING BREAKERS IN THIS PANEL. 2. GFI BREAKER PER NEC 210.8 3. 4_ 5. 6. TOTAL DEMAND CURRENT 0 208Y/120V 30 146.3 AMPS ALL SINGLE-PHASE RECEPETACLES RATED 150 VOLTS TO GROUND OR LESS, 50 AMPERES OR LESS AND THREE-PHASE RECEPTACLES RATED 150 VOLTS TO GROUND OR LESS, 100 AMPERES OR LESS INSTALLED SHALL HAVE GROUND -FAULT CIRCUIT -INTERRUPTER PROTECTION FOR PERSONNEL. r % ELECTRICAL SYMBOL LEGEND SYMBOL DESCRIPTION JUNCTION BOX WITH TWO (2) DUPLEX (20A; 125V.) RECEPTACLES JUNCTION BOX WITH DUPLEX (20A; 125V.) RECEPTACLE © JUNCTION BOX ® JUNCTION BOX WITH SPECIAL PURPOSE ® JUNCTION BOX WITH ISOLATED GROUND RECEPTACLE TP TAMPER RESISTANT GFCI DUPLEX RECEPTACLE/USB COMBO MOUNTED AT 18" AFF. IN PUBLIC AREAS. EC SHALL PROVIDE PASS AND SEYMOUR "SAFELOCK" 2095-TR-* ("*" I -IVORY, W=WHITE, GRY=GRAY, BK=BLACK, RED=RED, LA=LIGHT ALMOND). SPECIFIED RECEPTACLE BECOMES DE - ENERGIZED UPON FAILURE OF GFI DEVICE. NO SUBSTITUTIONS. (TYPICAL) RACEWAY CONCEALED IN WALL OR CEILINGS HOMERUN TO PANEL PB = Pullbox VIF =Verify in Field ELECTRICAL SCHEDULE JB = Junction Box EC = Electrical Contractor TAG # QTY DESCRIPTION VOLT/PH FLA BRK SIZE COND/WIRE PNUCCT RECEP TYPE HGT AFF REQUIREMENTS & REMARKS 004.20E6 1 MENU BOARD - DIGITAL 120/1 ISOLATED 2.6 20A 2 #12, 1 #12 IG AND 1 #12 EG - 1/2"C NOTE 1 IG5262 004.20E7 1 FREESTANDING DIGITAL MERCHANDISER 120/1 2.6 20A 2 #12, 1 #12 IG AND NOTE 1 IG5262 CLG - ISOLATED 1 #12 EG - 1/2"C 004.23E2 1 DIGITAL MERCHANDISER - MEDIA PLAYER DATA CABLE - - - JB 6'-5" JB W/ VC. TO FULL HEIGHT WALL AND TO ABOVE CEILING W/ BUSHING FOR DATA CABLES. SUPPLY W/ GROMMETED OPENING IN COVER PLATE 012.03E2 1 BAKED GOODS DISPLAY CASE 120/1 1.5 20A 2 #12, 1 #12EG - 1/2"C AP4-27 5-15R SEE RMKS PROVIDE RECEP. IN COUNTER -MOUNTED RACEWAY 009.14E1 1 UTILITY CHASE D/T BEVERAGE VERSION - - - - SEE RMKS CHASE AND RECEPTACLES BY KES 009.15E1 1 UTILITY CHASE D/T BOOTH - - - - - SEE RMKS CHASE AND RECEPTACLES BY KES 020.00E2 1 AUTOMATED BEVERAGE SYSTEM 120/1 5.0 20A 2 #12, 1 #12EG -1/2"C NOTE 1 5-20R 2'-0" EC TO BRING POWER DOWN WALL, PROVIDE/INSTALL RECEPTACLE 020.00E3 1 AUTOMATED BEVERAGE SYSTEM DATA CABLE - - - - - SEE RMKS CABLE FURNISHED/INSTALLED BY POS INSTALLER 020.99E2 1 ASS PRECOOLER 120/1 14.9 20A 2 #12, 1 #12EG - 1/2"C NOTE 1 5-20R YAW EC TO BRING POWER DOWN WALL, PROVIDE/INSTALL RECEPTACLE 039.15E3 1 ICE MACHINE - 1000 LB 120/1 1.1 15A 2 #12, 1 #12EG - 1/2"C NOTE 1 5-15R @ CLG CIRCUIT BREAKER SHALL BE HACR TYPE 041.09E1 1 ICE MACHINE REMOTE CONDENSER - 1000 LB 208/3 10.8 15A 3 #12, 1 #12EG - 1/2"C NOTE 1 SEE RMKS SEE RMKS EC TO PROVIDE WP 30A-31P NF DISC AT UNIT ON ROOF. CIRCUIT BRAKERS SHALL NE HACR TYPE. CONTROL WIRE TO ICE MACHINE LOCATION BY ACM 044.29E1 1 BREAKER PANEL 125 AMP - 3 PHASE EQUIPMENT MOUNTED 120-208/3 SEE RMKS 125A 4 #1, 1 #6 E.G. - 1 1/2"C NOTE 1 SEE RMKS EC TO EXTEND EXISTING SERVICE AS REQ & CONNECT TO PANEL 044.98E1 1 48" HLS TABLE 120/1 11.0 20A 2 #12, 1 #12EG - 1/2"C 044.29E1 - SEE RMKS EC TO EXTEND CIRCUIT TO KES OUTLET TO CHASE 129.00E2 2 Q'ING OVEN 208/1 20 20A 2 #12, 1 #12EG - 1/2"C AP4-(32,34)(36,38) 6-20R 5'-6" PLUGS INTO OVERHEAD RECEPTACLE #32OC6W(B) PROVIDE BY KES HEIGHT TO BOTTOM OF RECEPTACLE 178.13E2 1 REACH -IN REFRIGERATOR - SINGLE WIDE 120/1 11.3 20A 2 #12, 1 #12EG - 1/2"C AP4-29 5-20R SEE RMKS EC TO BRING POWER DOWN CHASE AND CONNECT TO CHASE MOUNTED RECEPTACLE 207.09E1 1 30" BASE REFRIGERATOR 120/1 3.2 20A 2 #12, 1 #12EG - 1/2"C AP4-31 5-20R 2'-0" EC TO BRING POWER DOWN WALL, PROVIDE/INSTALL RECEPTALE 207.10E1 1 FINISHING STATION 120/1 8.0 20A 2 #12, 1 #12EG - 1/2"C AP4-33 5-20R 2'-0" EC TO BRING POWER DOWN WALL, PROVIDE/INSTALL RECEPTALE 207.11 E4 1 BASE REFRIGERATOR 120/1 3.2 20A 2 #12, 1 #12EG - 1/2'C AP4-31 5-20R 2'-0" EC TO BRING POWER DOWN WALL, PROVIDE/INSTALL RECEPTALE 210.00E10 1 FUTURE CASH RECYCLER 120/1 ISOLATED 4.4 20A 2 #12, 1 #12 IG AND 1 #12 EG - 1/2"C AP4-35 (2) IG4700 SEE RMKS PROVIDE RECEPTACLE IN COUNTER -MOUNTED RACEWAY 211.00E6 2 DELIVERY TABLETS 120/1 3.0 20A 2 #12, 1 #12EG - 1/2"C AP4-37 (2) 5-20P 5'-6" - 213.00E10 1 TABLET BRACKET 120/1 ISOLATED 2.6 20A 2 #12, 1 #12 IG AND 1 #12 EG - 1/2"C NOTE 1 SEE RMKS SEE RMKS PROVIDE IG RECEPTACLE IN COUNTER -MOUNTED RACEWAY 213.00E1 I 1 TABLET BRACKET 120/1 ISOLATED 1.5 20A 2 #12, 1 #12 IG AND 1 #12 EG - 1/2"C SEE RMKS 5-20R SEE RMKS EXTEND NEARBY APPLIANCE PANEL CIRCUIT TO NEW RECEPTACLE 215.00E3 1 POS REGISTER - FRONT COUNTER DATA CABLE - - - - PB 10" EXTEND 2" CONDUIT TO ABOVE CEILING FOR POS DATA CABLES 215.00E12 1 POS REGISTER - FRONT COUNTER 120/1 ISOLATED 3.0 20A 2 #12, 1 #12 IG AND 1 #12 EG - 1/2"C NOTE 1 IG4700 SEE RMKS PROVIDE IG RECEPTACLE IN COUNTER -MOUNTED RACEWAY 215.00E15 1 POS REGISTER - FRONT COUNTER DATA CABLE - - - PB 10" EXTEND TWO 1" CONDUITS TO ABOVE CEILING FOR POS DATA CABLES 215.05E2 1 NEW KVS MONITOR DATA CABLE - - - - - SEE RMKS CABLE FURNISHED AND INSTALLED BY POS SUPPLIER 215.05E3 1 NEW KVS MONITOR 120/1 ISOLATED 1.5 20A 2 #12, 1 #12 IG AND 1 #12 EG - 1/2"C AP4-39 IG4700 SEE RMKS DOWN CHASE, POS INSTALLER TO MAKE FINAL CONNECTIONS 215.07E1 1 POS REGISTER - DELIVERY 120/1 ISOLATED 3.0 20A 2 #12, 1 #12 IG AND 1 #12 EG - 1/2"C AP4-39 IG4700 42" 215.07E3 1 POS - KVS MONITOR - - - PB 42" EXTEND 2" CONDUIT TO ABOVE CEILING FOR POS DATA CABLES 216.00E2 2 POS - VIDEO MONITOR DATA CABLE - - - - - - CABLE FURNISHED/INSTALLED BY POS INSTALLER 216.00E3 1 POS - VIDEO MONITOR W/ SUPPORTS 120/1 ISOLATED 1.5 20A 2 #12, 1 #12 IG AND 1 #12 EG - 1/2"C AP4-39 IG4700 @ CLG EC TO PROVIDE/INSTALL RECEPTACLE, POS INSTALLER TO CONNECT POS 216.00E7 1 POS - VIDEO MONITOR W/ SUPPORTS @ CHASE 120/1 ISOLATED 1.5 20A 2 #12, 1 #12 IG AND 1 #12 EG - 1/2"C AP4-39 IG4700 SEE RMKS EC TO BRING POWER DOWN CHASE AND CONNECT TO CHASE MOUNTED RECEPTACLE 216.00E11 1 POS - VIDEO MONITOR 120/1 ISOLATED 1.5 20A 2 #12, 1 #12 IG AND 1 #12 EG - 1/2"C AP4-39 IG4700 T-6" CABLE PROVIDED AND INSTALLED BY POS SUPPLIER 216.00E12 1 POS - VIDEO MONITOR DATA CABLE - - - 4x4x4 PB 5'-6" EXTEND 2" CONDUIT ABOVE CEILING. CABLE FURNISHED AND INSTALLED BY POS SYSTEM SUPPLIER 216.04E1 1 ORB MONITOR (MINI) 8 SCANNER 120/1 ISOLATED 1.5 20A 2 #12, 1 #12 IG AND 1 #12 EG - 1/2"C AP4-39 (2) IG4700 V-6" 216.05E4 1 ORB MONITOR 120/1 ISOLATED 1.5 20A 2 #12, 1 #12 IG AND 1 #12 EG - 1/2"C NOTE 1 IG4700 8'-1" - 216.05E5 1 ORB MONITOR 120/1 ISOLATED 1.5 20A 2 #12, 1 #12 IG AND 1 #12 EG - 1/2"C NOTE 1 IG4700 8'-1" JB W/ 1-1/2"C. TO TERMINATE ABOVE CEILING WBUSHINGS FOR DATA CABLE SUPPLY W/ GROMMETED OPENING IN COVER PLATE. 217.00E1 3 PARK/ROTATE/SERVE BUMP BAR DATA CABLE - - - - SEE RMKS POS TO COORD W/ MCD 0/0, RELCOATED EXIST AS REQUIRED 219.00E10 2 POS - RECEIPT PRINTER 120/1 ISOLATED 0.7 20A 2 #12, 1 #12 IG AND 1 #12 EG - 1/2"C NOTE 1 IG4700 SEE RMKS PROVIDE IG RECEPTACLE IN COUNTER -MOUNTED RACEWAY 219.02E2 3 CYT POS - RECEIPT PRINTER 120/1 ISOLATED 0.7 20A 2 #12, 1 #12 IG AND 1 #12 EG - 1/2"C NOTE 1 IG4700 TBD POS INSTALLER TO COORDINATE WITH MCD 219.05E3 1 STICKY LABEL PRINTER 120/1 ISOLATED 0.7 20A 2 #12, 1 #12 IG AND 1 #12 EG - 1/2"C AP4-39 IG4700 38" FOR DELIVERY STATION 700.09E1 1 ECONOMY OEP BOX W/ MOUNTING HARDWARE - - - SEE RMKS CEILING MOUNTED 701.13E16 1 DCO - GENERAL PURPOSE 120/1 1.5 20A 2 #12, 1 #12EG - 1/2"C AP4-27 5-20P SEE RMKS PROVIDE RECEPTACLE IN COUNTER -MOUNTED RACEWAY 7000.12E2 1 HOT WATER DISPENSER 120/1 15.4 20A 2 #12, 1 #12EG - 1/2"C AP4-41 5-20R SEE RMKS PLUGS INTO CENTER ISLAND BREAKER PANEL OR OUTLET HOUSING 8021.01E2 3 RELOCATED COFFEE BREWER - - - NOTE 1 - GC TO VERIFY AND REQORK ALL EXISTING UTILITES AS REQUIRED 8021.10E2 1 RELOCATED SPECIALTY COFFEE - - - NOTE 1 - - GC TO VERIFY AND REQORK ALL EXISTING UTILITES AS REQUIRED 8021.11E2 1 RELOCATED SMOOTHIE MACHINE - - - NOTE 1 - - GC TO VERIFY AND REQORK ALL EXISTING UTILITES AS REQUIRED 8021.98E2 1 RELOCATED SUGAR DISPENSER - - - NOTE 1 - - GC TO VERIFY AND REQORK ALL EXISTING UTILITES AS REQUIRED 8023.05E2 2 RELOCATED CREAM DISPENSER - - - - NOTE 1 GC TO VERIFY AND REQORK ALL EXISTING UTILITES AS REQUIRED 8024.01E1 1 RELOCATED ORANGE JUICE DISPENSER, DUAL FLAVO - NOTE 1 GC TO VERIFY AND REQORK ALL EXISTING UTILITES AS REQUIRED 8025.02E2 1 RELOCATED ICED TEA BREWER - - - - NOTE 1 - - GC TO VERIFY AND REQORK ALL EXISTING UTILITES AS REQUIRED 8039.09E1 1 RELOCATED ICE MACHINE - - - NOTEII - GC TO VERIFY AND REQORK ALL EXISTING UTILITES AS REQUIRED 6118.00E1 1 RELOCATED Q'ING OVEN - - - NOTE 1 - GC TO VERIFY AND REQORK ALL EXISTING UTILITES AS REQUIRED 8118.00E3 1 RELOCATED Q'ING OVEN - - NOTE 1 - GC TO VERIFY AND REQORK ALL EXISTING UTILITES AS REQUIRED 8118.00E5 1 RELOCATED Q'ING OVEN - - NOTE 1 - GC TO VERIFY AND REQORK ALL EXISTING UTILITES AS REQUIRED 8122.27E1 1 RELOCATED HRT TOASTER - NOTE 1 GC TO VERIFY AND REQORK ALL EXISTING UTILITES AS REQUIRED 8131.02E1 1 RELOCATED BISCUIT OVEN - - NOTE 1 - - GC TO VERIFY AND REQORK ALL EXISTING UTILITES AS REQUIRED 8178.08E1 2 RELOCATED REACH -IN REFRIGERATOR - NOTE 1 - GC TO VERIFY AND REQORK ALL EXISTING UTILITES AS REQUIRED 8181.01E2 1 RELOCATED REFRIGERATOR - SPECIALTY COFFEE - NOTEII - - GC TO VERIFY AND REQORK ALL EXISTING UTILITES AS REQUIRED 8203.02E2 1 RELOCATED COMBO SHAKE/SUNDAE MACHINE - - - NOTE 1 - - GC TO VERIFY AND REQORK ALL EXISTING UTILITES AS REQUIRED 8205.11E2 1 RELOCATED FROZEN CARBONATED BEVERAGE - - - NOTE 1 - GC TO VERIFY AND REQORK ALL EXISTING UTILITES AS REQUIRED 8207.09E1 1 RELOCATED BASE REFRIGERATOR - - NOTE 1 - - GC TO VERIFY AND REQORK ALL EXISTING UTILITES AS REQUIRED 8215.05E2 4 RELOCATED KVS MONITOR - - NOTE 1 - GC TO VERIFY AND REQORK ALL EXISTING UTILITES AS REQUIRED 8215.05E3 4 RELOCATED KVS MONITOR - - NOTE 1 - GC TO VERIFY AND REQORK ALL EXISTING UTILITES AS REQUIRED 8215.98E1 1 RELOCATED POS PC HARDWARE - 2 BOOTH D/T - - NOTE 1 - - GC TO VERIFY AND REQORK ALL EXISTING UTILITES AS REQUIRED 8215.98E2 2 RELOCATED POS PC HARDWARE - 2 BOOTH D/T - - NOTE 1 - - GC TO VERIFY AND REQORK ALL EXISTING UTILITES AS REQUIRED 8216.00E2 2 RELOCATED POS - VIDEO MONITOR - - NOTE 1 - GC TO VERIFY AND REQORK ALL EXISTING UTILITES AS REQUIRED 8216.00E7 2 RELOCATED POS - VIDEO MONITOR @ CHASE - NOTE 1 - GC TO VERIFY AND REQORK ALL EXISTING UTILITES AS REQUIRED 8217.00E1 2 RELOCATED PARK/ROTATE/SERVE BUMP BAR - - - NOTE 1 - GC TO VERIFY AND REQORK ALL EXISTING UTILITES AS REQUIRED 8217.13E2 1 RELOCATED MERGE POINT MONITOR - - NOTE 1 - GC TO VERIFY AND REQORK ALL EXISTING UTILITES AS REQUIRED 8219.00E7 1 RELOCATED POS-RECEIPT PRINTER - NOTE 1 - GC TO VERIFY AND REQORK ALL EXISTING UTILITES AS REQUIRED 8219.00E8 1 RELOCATED POS-RECEIPT PRINTER - - NOTE 1 GC TO VERIFY AND REQORK ALL EXISTING UTILITES AS REQUIRED 8327.00E1 1 RELOCATED PIE DISPLAY INOTE1 - GC TO VERIFY AND REQORK ALL EXISTING UTILITES AS REQUIRED NOTE: 1. USE EXISTING CIRCUITRY, CONTRACTOR TO VERIFY EXISTING CIRCUITS AND BREAKER SIZE. UPGRADE BREAKER AND CIRCUIT TO MATCH NEW EQUIPMENT REQUIREMENTS IF EXISTING CIRCUIT IS TOO SMALL. VERIFY EXISTING CIRCUIT NUMBERS AND RECORD ON AS -BUILT DRAWINGS FOR INSPECTORS REVIEW DURING ROUGH -IN INSPECTION. SEE SHEET E2.0 FOR REQUIREMENTS ELECTRICAL ROUGH -IN INFORMATION CONTRACTOR TO FIELD VERIFY CIRCUIT NUMBERS AND EXACT NUMBER OF SPARES AVAILABLE. M N rM O p Lm • fh • C 0 rA � 3 + U• • w C) • 9 THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY ADAM T. =M=RALD POWELL, PE USING A DIGITAL SIGNATURE AND DATE. PRINTED COPIES ENGINEERING I N Q OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND 9942 CURRIE DAVIS DR. STE H.,TAMPA, FL 33619 THE SIGNATURE MUST BE VERIFIED ON TEL (813) 995-0300 ANY ELECTRONIC COPIES. WWW.EMERALDMEP.COM EEI PROTECT* 22072M I LEI a 0 m w 1802.31 • 0 M-0003276 04.: PULLBOX FOR DATA PROVIM 2 IG5262 RECE PROVIDED BY E.11 Q004.211El 04. CONDUIT BY E.C. TO Elf LOCATION TO ALIGN WfTH ADJACENT DECOR WALL Pill ACCESS PANEL 1 TO ALLOW CABLE & CONDUIT ROU , INTERIOR ELEVATIONS 1 /2" = 1'-0" F • • • ►I F• 1 . r' , 1 7 1Ila in • SIDE BY •Cs,�S������ HANDI R JB WITH ONE (1) 1 1/2" CONDUIT TO Nwm- 11. TINR EXAMPLE 6 FOR A SIDE BY SIDE CASH HANDLER THAT DOES NOT NOR A OC FI AL. NOW WALL KHWD IT AND LR NE U TO A KIOSK. 2 EACH $WE BY SIDDE CASH HANDLER UTILIZES 3 PW6S AND ADDS 4.4 AMPi OF LOAD. FUTURE CASH HANDLER POWER DETAIL 1'-010 DATA CABLE ]F7 F7 F7 F • 1 • 7� MEDIA PLAYER mum= Boom SCRIM FAM 10 bmnlllJCR01i 1. DKK#L MERCHANDW CHANNELS ARE DESWNED TO REACH UP TO A 1O' CEILING. W CE1LMKi IS TAIMIR, E liffDDER KIT CAN EIE ORDERED TO REACH 12'. FUTURE CASH HANDLER POWER DETAIL 1 /4" = 1'-0" NOTES 1❑ THIS SLIP SHEET IS PROVIDED FOR ELECTRICAL ROUGH -IN PREPARATION AND GENERAL DIGITAL MENU BOARD MOUNTING GUIDELINES. EVALUATE EXISTING VALANCE WALL STRUCTURE AND BACKING MATERIALS TO ENSURE ADEQUATE SUPPORT OF Moul2m2am 02 ALL HEADER AND WALL PENETRATIONS FOR CONDUITS OR OTHER ELECTRICAL ROUTING MUST BE SEALED TIGHT. DIGITAL MENU BOARD (DMB) INSTALLATI • DMB SUPPORT EQUIPMENT INCLUDES: - NETWORK MANAGEMENT DEVICE (NMD) - 24 PORT ENHANCED WAYPORT SWITCH (EWS) THIS EQUIPMENT IS TYPICALLY MOUNTED IN TECHNOLOGY CLOSET OR IN MANAGER'S OFFICE. • DMB INSTALLERS TO ROUTE CONTROL WIRES FROM NMD/EWS ABOVE CEILING TO MENU BOARD VALANCE WALL. WIRES TO EXIT WALL VIA J-BOXES. • EACH DMB SECTION REQUIRES A DEDICATED MEDIA PLAYER. 1 1 RECESSED MENU BOARDS 1 " = 1'-011 z 0 rn 0 W W 12 N M O z 0 ff 0 I� 4 0 • M L M • • yea ,$ ' Q)00 00 w A C� 0 _ LEI 0 Ld O THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY ADAM T. _�-���� 1802.31 POWELL, PE USING A DIGITAL SIGNATURE AND DATE. PRINTED COPIES E ENGINEERING I N Q OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND 9942 CURRIE DAVIS DR. STE H., TAMPA, R. 33619 0 THE SIGNATURE MUST BE VERIFIED ON (813) 995-0300 • ANY ELECTRONIC COPIES. WWW.EMERALDMEP.COM EEI PROJECT* 22072M - ------+- 0 0 0 AD 0 0© 1 I; Neutral ■ ■ ■ ■ ■ ■ ■ ■ ■m1m UP TO - PHOTOCELL 10 ON ROOF. ®EX' A LIGHTING FIXTURES POWER L I MANUAL SWITCH PACK T (if shown on drawings) LOW VOLTAGE CABLE OCCUPANCY SENSOR NOTES: 1. REFER TO LIGHTING PLAN FOR OCCUPANCY SENSOR LOCATIONS AND QUANTITIES. OCCUPANCY SENSOR CONTROL DETAIL . .. ...... ........ . 6 _ _ .___._ __� �__ 7.. ...... .... ._.-__._ ... LIGHTING FIXTURE SCHEDULE NOTES: 1. ORDER LED EXIT SIGNS WITH LETTER COLORS THAT COMPLY WITH LOCAL CODES FROM SECURITY LIGHTING. FOR RED LETTERS USE #PRB (UNIVERSAL) FOR GREEN LETTERS USE #PGB (UNIVERSAL) OR IF THE ABOVE EXIT SIGNS DO NOT COMPLY WITH LOCAL CODES USE, LED SIGN WITH BATTERY BACKUP, LETTER SIZE, COLOR, TYPE AND DIRECTIONAL ARROWS AS REQUIRED BY THE LOCAL AUTHORITIES. 2, BEFORE ORDERING VERIFY WITH LOCAL MUNICIPALITY THAT THIS FIXTURE COMPLIES WITH ANY LOCAL LIGHTING ORDINANCE. EMERGENCY LIGHTING NOTES: 1. CONNECT ALL EXIT SIGNS, EMERGENCY LIGHTS, INVERTER AND NIGHT LIGHTS TO THE EXISTING EXIT/EMERGENCY LIGHTING CIRCUIT. 2. CONNECT ALL EXIT SIGNS, EMERGENCY LIGHTS AND NIGHT LIGHTS TO ONE CIRCUIT BREAKER. 3. LIGHTING INDICATED WITH A "NL" ARE NIGHTLIGHTS AND SHALL BE CONNECTED TO THE UNSWITCHED LEG OF THE CIRCUIT. 4. EMERGENCY LIGHTING HAS BEEN DESIGNED PER NFPA 101 MAINTAIN 1 FC IN PATH OF EGRESS. IF FIELD CONDITIONS REQUIRE ANY CHANGES TO LIGHTING DESIGN, EMERGENCY LIGHTING, SHALL BE INSTALLED TO MEET THE ABOVE REQUIREMENTS. LIGHTING FIXTURE SCHEDULE SYMBOL DESCRIPTION MANUFACTURES CAT. NO. VOLTAGE LAMPS MOUNTING A LED DOWN RADIUS WALL SECURITY LIGHTING SYSTEMS NO.: 14W WALL MOUNT E WALL WASHER SECURITY LIGHTING SYSTEMS NO.: 16 CEILING RECESSED ® SCONCE - SILVER FINISH RWSC-36LED-5K-DO-U-PS 120 RDA-60LM30-NF-S/RDA-60-H 120 SEE LIGHTING FIXTURE SCHEDULE NOTE NO. 2 LED CAN LIGHT SECURITY LIGHTING SYSTEMS NO.: 12W CEILING RECESSED E BLUE ROUND PENDANT SECURITY LIGHTING SYSTEMS NO.: 12 PENDANT HUNG P RDA- 1 36LM-30-FL-S/RDA- 1 36-H 120 ® 7652 BLE-EQL-306-45358-1-LED 120 REFER TO DECOR DRAWINGS FOR EXACT FIXTURE TYPE LED CAN LIGHT FED FROM SECURITY LIGHTING SYSTEMS NO.: 12W CEILING RECESSED G SLIM PENDANT GREY LARGE SECURITY LIGHTING SYSTEMS NO.: 20 CEILING RECESSED BE O UNSWITCHED INVERTER PANEL RDA-1 36LM-30-FL-S/RDA-1 36-H 120 6797-BPS-1388-71 120 NL FOR USE AS NIGHT LIGHT AND REFER TO DECOR DRAWINGS FOR EXACT FIXTURE EMERGENCY LIGHT. TYPE 2x4, LED LAY -IN PRISMATIC SECURITY LIGHTING SYSTEMS NO.: 44W CEILING LAY -IN ACRYLIC LENS LCAT24-35HLG-EDU-WP-GK 120 ® COMBO WITH BATTERY BACK-UP 120 UNIT 2x4, LED LAY -IN PRISMATIC ACRYLIC SECURITY LIGHTING SYSTEMS NO.: 44W CEILING LAY -IN EMERGENCY BATTERY AND DUAL LITE 2-5W SURFACE TO WALL E LENS FED FROM UNSWITCHED LCAT24-35HLG-EDU-WP-GK 120 X 2 REMOTE HEAD EV4D-02L-0/EVODB 120 OR SOFFIT INVERTER PANEL FOR USE AS NIGHT WHEN CONNECTED TO TWO REMOTE HEADS NI- LIGHT AND EMERGENCY LIGHT. (FOR SINGLE GANG JUNCTION BOX) DELIVERY POD LED LIGHT SECURITY LIGHTING SYSTEMS NO.: 9W CEILING RECESSED DENOTES EXISTING DEVICE TO DP LB4-6LD-30K-9-GD/IBX4QL-120 120 EX REMAIN (PROVIDED WITH DELIVERY POD) D 2 HEAD DOUBLE GIMBALL SECURITY LIGHTING SYSTEMS NO.: 14 CEILING RECESSED CEILING -MOUNTED LIGHTING INVERTER WITH MAINTENANCE FREE SEALED 00 (MULTIPLE 25 DEGREE) GM2-120-LM-30-SBS 120 �J LEAD CALCIUM BATTERY. REFER TO DECOR DRAWINGS FOR EXACT FIXTURE SECURITY LIGHTING SYSTEMS LG1 SERIES TYPE INVERTER MAXIMUM OF FOUR 12.5 WATT CAN LIGHTS PER INVERTER DE 2 HEAD DOUBLE GIMBALL FED FROM SECURITY LIGHTING SYSTEMS NO.: 14 CEILING RECESSED m UNSWITCHED LIGHTING CIRCUIT GM2-120-LM-30-SBS 120 FOR USE AS NIGHT LIGHT AND REFER TO DECOR DRAWINGS FOR EXACT FIXTURE NL EMERGENCY LIGHT TYPE �1!! 00, �po `,, Fs Rks CI VIEW GATE; r •C'� ;L.t._ ��P��)xx Z,_SO4e �c�i TY OF ZEPHYR ' `S - �Lq�cF� OFR/ccvi�� 'yirh BUILDING' HILLS - OFFICIAL /Ike--. .. - 12 � t X A 13 �. LIGHTING PLAN SCALE: 1/4" = V-0" GENERAL NOTES 1. EC SHALL FIELD VERIFY THAT ALL LIGHT FIXTURES SHOWN ON THIS PLAN DO NOT OBSTRUCT OR CONFLICT WITH THE WORK OF OTHER TRADES. IF A DISCREPANCY IS FOUND, THE EC SHALL IMMEDIATELY NOTIFY THE GC BEFORE THE INSTALLATION OF SUCH FIXTURE(S).. 2. IF PC-POS CASH REGISTER SYSTEM IS INSTALLED, RELOCATE FIXTURES ABOVE FRONT COUNTER TO AVOID GLARE ON THE CASH REGISTER SCREENS. INSTALL CABLE WHIP TO FIXTURES SO THAT FIXTURE CAN BE RELOCATED FOUR FEET WITHOUT DISCONNECTING CABLE WHIP. 3. THE USE OF "MC" CABLE WHERE PERMITTED BY LOCAL CODES WILL BE ALLOWED FOR ALL WIRING TO THE LIGHT FIXTURES. "ROMEX" & "BX" ARE NOT ACCEPTABLE. 4. LIGHTING FIXTURES AND LAMPS HAVE BEEN CHOSEN TO ACHIEVE MAXIMUM ENERGY CONSERVATION WHILE MAINTAINING ADEQUATE LEVELS OF ILLUMINATION. LAMP SPECIFICATIONS MUST BE STRICTLY FOLLOWED. ANY DEVIATION FROM LAMP SPECIFICATIONS MUST BE APPROVED IN WRITING BY McDONALD'S CORPORATION. 5. ALL BRANCH CIRCUIT WIRING TO 120 VOLT LIGHTING FIXTURES AND RECEPTACLES SHALL BE AS FOLLOWS. MAXIMUM LENGTH 85FT. - 2 #12, 1 #12 E.G. MAXIMUM LENGTH 140FT. - 2 #10, 1 #10 E.G. MAXIMUM LENGTH 225FT. - 2 #8, 1 #8 E.G. MAXIMUM LENGTH 350FT. - 2 #6, 1 #6 E.G. 6. ALL EXTERIOR J-BOXES AND RECEPTACLES SHOWN ON THIS PLAN SHALL BE WATERPROOF. IF SIGNAGE DOES NOT COME WITH DISCONNECT SWITCH PROVIDE TOGGLE SWITCH WITH WEATHERPROOF COVER. ORDER ALL LIGHT FIXTURES FROM: SECURITY LIGHTING SYSTEMS, INC. PHONE: 1-800-LIGHT-IT EMAIL: QUOTATIONS@SECURITYLIGHTING.COM VERIFY LIGHTING FIXTURE CATALOGUE NUMBERS WITH INTERIOR DESIGNER PRIOR TO ORDERING FIXTURES. 14 WP J-BOX FOR J McDONALDS I FASADE SIGN J _11x;� ^ • • cy 4 3 + +J U • K >1Q). .> Q^ } c- ii o0 •�4 ;E z ® CL Q �a o NL c �•S� V � �o 3 J e ea�� �v iv a 4N 0 = j c iL�ppc�`0°o0 aC g� v �IE Cr ° O KEYNOTE LEGEND _J 1. CONNECT TO EXISTING CUSTOMER SERVICE LIGHTING CIRCUIT SERVING THIS AREA. 2. CONNECT TO EXISTING DINING AREA LIGHTING CIRCUIT SERVING THIS AREA. 3. CONNECT TO THE EXISTING EXIT/EMERGENCY/NIGHT LIGHTING CIRCUIT. 4. EXISTING LIGHTING AND EMERGENCY LIGHTING IN THIS ARE TO REMAIN AS IS. 5. CONNECT TO EXISTING TOILET LIGHTING CIRCUIT THAT WAS MADE SPARE BY DEMOLITION. 6. PROVIDE CEILING MOUNTED ULTRASONIC OCCUPANCY SENSOR IN RESTROOMS (HUBBELL ATU500C). AIM SENSOR IN DIRECTION INDICATED BY ARROW FOR MAXIMUM COVERAGE OF ROOM. REFER TO OCCUPANCY SENSOR DETAIL ON THIS SHEET. ORDER ALL OCCUPANCY SENSORS FROM, SECURITY LIGHTING LIGHTING SYSTEMS, INC. 7. EACH RESTROOM HAS ONE SENSORS THAT CONTROL ALL LIGHTS TOGETHER AT ONCE IN RESPECTIVE RESTROOM. 8. CONNECT TO UNSWITCHED LEG OF THE RESTROOM LIGHTING CIRCUIT TO FEED INVERTER. 9. CONNECT TO EXISTING KITCHEN/SUPPORT AREA LIGHTING CIRCUIT SERVING THIS AREA. 10. CONNECT TO EXISTING PHOTOCELL EXTERIOR SECURITY LIGHTING CIRCUIT. 11. EC SHALL INSTALL AND CONFIGURE REMOTE EMERGENCY LIGHTING AT ALL EGRESS EXTERIOR DOORS FOR MAXIMUM ILLUMINATION AT POINTS OF EGRESS. INSTALL WP J-BOX WITH IN SOFFIT TO ALLOW A FLUSH INSTALLATION OF ANY EXTERIOR EMERGENCY EGRESS LIGHTING (TYPICAL). 12. CONNECT TO EXISTING EXTERIOR LIGHTING WALL SCONCE CIRCUIT. 13. REFER TO ARCHITECTURAL ELEVATIONS FOR HEIGHTS AND LOCATIONS OF WALL SCONCE AND CANOPY DOWNLIGHTS. 14. EXISTING FRONT FASADE SIGN CIRCUIT. LOAD SUMMARY NO ADDITIONAL LOAD ADDED. LOADS ADDED ARE OFFSET BY LOADS REMOVED BY DEMOLITION THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY ADAM T. POWELL, PE USING A DIGITAL SIGNATURE AND DATE. PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES. ENGINEERING INC. 9942 CURRIE DAVIS DR. STE H., TAMPA, FL 33619 r TEL(813) 995-0300 WWW.EMERALDMEP.COM EEI PROJECT# 22072M m 8 O LaiL0 N 8o a ix p 13- sZ Lv 0 0 W O Z 8� 1802.31 E 1 0 • AA-0003276 E N I _ ....... _ _ 1 a ' K;' 00= EXISTING PANEL AP4 EXISTING ELECTRICAL MDP, AP1, AP2 AND AP3 GENERAL NOTES: WIRE/RACEWAY: imm EXISTIN PANELL AP2 C 020.00 211.006 020.00 J J 020.99 J j { AP1-13 18207.09O 215.07 E1 •"� Iamnnnuumvr _.___.._�....... .. i 4 W � 216.00 E11 217.00 E1 219.05 E3 1. ALL WORK SHALL BE IN ACCORDANCE WITH THE 2017 NATIONAL ELECTRICAL CODE 1. ALL CONDUCTORS SHALL BE COPPER, CONDUCTOR INSULATION SHALL BE DUAL TYPE AND SHALL ALSO COMPLY WITH ALL APPLICABLE RULES AND REGULATIONS OF LOCAL THHN/THWN 75'C. (167°F) FOR DRY, DAMP, AND WET LOCATIONS. CONDUCTOR AND STATE LAWS AND ORDINANCES. INSULATION WITH SINGLE TYPE MARKING THHN 90"C (194-F) MAY BE USED FOR DRY LOCATIONS ONLY. ALL CONDUCTORS SHALL BE COLOR CODED AS REQUIRED BY NEC 2. CONTRACTOR SHALL MAKE A THOROUGH EXAMINATION OF THE SITE AND THE AND FURTHER IDENTIFIED AND CODED AS SPECIFIED HEREINAFTER. COLOR CODING CONTRACT DOCUMENTS_ NO CLAIM FOR EXTRA COMPENSATION WILL BE SHALL BE BY MEANS OF COLORED INSULATING MATERIAL, COLORED BRAID OR RECOGNIZED IF DIFFICULTIES ARE ENCOUNTERED WHICH AN EXAMINATION OF SITE JACKET OVER THE INSULATION OR BY MEANS OF SUITABLE COLORED, PERMANENT, CONDITIONS AND CONTRACT DOCUMENTS PRIOR TO EXECUTING CONTRACT WOULD NON -AGING, INSULATING TAPE APPLIED TO CONDUCTORS AT EACH CABINET OR HAVE REVEALED. JUNCTION POINT. THE COLOR CODING SHALL BE ACCOMPLISHED AS THE CONDUCTORS ARE INSTALLED. THE FOLLOWING SYSTEMS OF COLOR CODING SHALL 3. ELECTRICAL CONTRACTOR SHALL ARRANGE FOR ALL NECESSARY PERMITS, BE STRICTLY ADHERED TO: LICENSES, UTILITY COORDINATION AND INSPECTIONS AS REQUIRED BY THE CITY OR UTILITY COMPANY. OWNER WILL PAY FEES. CONTRACTOR IS RESPONSIBLE FOR ALL A) GROUND LEADS: GREEN EQUIPMENT REQUIRED BY UTILITY COMPANY AND SHOULD INCLUDE NECESSARY COSTS IN BID. B) 120/208 VOLT UNGROUNDED PHASE WIRES: PHASE A: BLACK 4. CONTRACTOR SHALL LEGIBLY MARK-UP A SET OF 24"x36" DRAWINGS TO REFLECT PHASE B: RED AS -BUILT CONDITIONS AND TURN OVER TO THE ARCHITECT. PHASE C: BLUE NEUTRAL: WHITE 5. PANELBOARD MANUFACTURER SHALL PROVIDE ARC -FLASH WARNING LABELES FOR MDP AND ALL BRANCH PANELBOARDS IN ACCORDANCE WITH NEC 110. THE COLOR CODE ASSIGNED TO EACH PHASE WIRE SHALL BE CONSISTENTLY FOLLOWED THROUGHOUT GROUNDING: 2. ALL BRANCH CIRCUIT WIRING TO 120 VOLT LIGHTING FIXTURES AND RECEPTACLES SHALL BE AS FOLLOWS. 1. THE INTERIOR ELECTRICAL SYSTEMS SHALL BE COMPLETELY AND EFFECTIVELY MAXIMUM LENGTH 85FT. - 2 #12, 1 #12 E.G. GROUNDED AS REQUIRED BY NATIONAL ELECTRICAL CODE ALL METALLIC RACEWAYS MAXIMUM LENGTH 140FT. - 2 #10, 1 #10 E.G. SHALL BE MECHANICALLY AND ELECTRICALLY SECURE AT ALL JOINTS AND AT ALL MAXIMUM LENGTH 225FT. - 2 #8, 1 #8 E.G. BOXES, CABINETS, FITTINGS AND EQUIPMENT. MAXIMUM LENGTH 350FT. - 2 #6, 1 #6 E.G. 3. UNLESS OTHERWISE NOTED ALL CONDUCTORS SHALL BE RUN IN THIN WALL CONDUIT OUTLET BOXES/DEVICES: AND THIN WALL CONDUIT SHALL BE UNDERWRITERS' APPROVED GALVANIZED ELECTRICAL METALLIC TUBING. COUPLINGS AND CONNECTORS SHALL BE STEEL 1. ALL OUTLET BOXES SHALL BE RIGIDLY MOUNTED AND SHALL BE EQUIPPED WITH SET -SCREW TYPE, ZINC OR CADMIUM PLATED. MC CABLE MAY BE USED WHERE SUITABLE SCREW FASTENED COVERS. OPEN KNOCKOUTS OR HOLES IN BOXES CONCEALED IN WALLS. SHALL BE PLUGGED WITH SUITABLE BLANKING DEVICE_ 4. ALL RACEWAYS SHALL BE PROPERLY ALIGNED, GROUPED, AND SUPPORTED BY 2. OUTLET BOXES SHALL BE 4 INCH SQUARE x 2-1/8" DEEP. OUTLET BOXES LOCATED MECHANICAL TYPE CADDY' CLIPS AT INTERVALS NOT EXCEEDING 8 FEET. ABOVE THE CEILING SHALL BE LEGIBLY IDENTIFIED WITH BRANCH CIRCUIT NUMBER OF CIRCUIT TERMINATED WITHIN BY MEANS OF BLACK PERMANENT MARKER. 5. ALL RACEWAYS WITH NO. 10 OR 12 AWG PHASE CONDUCTORS FOR RECEPTACLES, LIGHTING FIXTURES AND SIMILAR CIRCUITS SHALL BE PROVIDE WITH A PARITY SIZED GREEN EQUIPMENT GROUND CONDUCTOR. GROUND CONDUCTOR SHALL BE SWITCHGEAR: INSTALLED IN ENTIRE RACEWAY SYSTEM INCLUDING WALL SWITCHES AND FLEXIBLE CONDUIT TO LIGHT FIXTURES. EQUIPMENT GROUND CONDUCTOR SIZES FOR 1. PANELBOARD DIRECTORY CARDS SHALL BE TYPEWRITTEN WITH ACCURATE AND CIRCUITS WITH PHASE CONDUCTORS LARGER THAN NO. 12 AWG ARE INDICATED ON CURRENT INFORMATION BY THE CONTRACTOR AT THE END OF CONSTRUCTION. DRAWINGS. GROUND CONDUCTORS SHALL BE CONNECTED TO GROUND BUSS IN PANELBOARDS. 6. RACEWAY PENETRATIONS OF FIRE RATED WALLS AND/OR FLOORS SHALL BE SEALED TO MAINTAIN INTEGRITY OF CONSTRUCTION. ALL PRODUCTS, MATERIALS AND METHODS OF INSTALLATION SHALL BE UL APPROVED AND MEET NFPA. 7. ALL ELECTRICAL CONDUITS SHALL BE CONCEALED IN WALLS UNLESS AS -BUILT CONDITIONS PROHIBITS. GC TO NOTIFY ARCH/ACM OF AS -BUILT CONDITIONS. AP4-42 0 I' ......... TP TP TP I f 215.00 E3 _0 210.00 E10 215.00 E12 219.00 JE10 215.00 E12 i 219.00 E10 iQz. 012.03 E2 1 213.00 E10 216.04 E1 701.13 E16 004.20 E6 \,., j 004.23 El) V 004.23 E2 J 215.00 1 E 15 %Ly (11_039.15 J E3 041.0 E 1 216.000 E2 II 216.00 E3 213.00E-11 �QC 21�00E 21 ......... . ..... POWER PLAN SCALE: 1/4" = V-0" 4 O 4 0 TP us m I� Z O ff ir U W 0 Z 0 T 0 0 W W V) W M N 0 O pso c � !v +!miteofz, �E009.14 E1 8181.01 E2 171 E2 8203-02 E2cd i • a 217.00 E 1 k 8205.11 E2 i W a 5 3 219.02 E2 8216.00 EE 2 I i 0 5 8021.10 E2 8216.00 7 O 8021.11 E2) _______----I • 3 _ 1 v� ------------ L 207.09 E 1 _. __ �� i I -� , i • z $ 207.10 E1 I I I I o 8025.02 E2 8039.09 E1 Z' ° N J �C N ....._r . It 8216.00 E2 cl) .8 .8 0 5 Q CL 8216.00 E7 8217.13 E2 © $- °ro 8219.00 E7 ( o 0 0 o c 8219.00 E8 cc 7000.12 o$co � _.. 'Dcsit o m c ° $`o 3 V w oa� o _:8 3 �o a 0 KEYNOTE LEGEND; sg 1. RACEWAY KIT PROVIDED WITH COUNTER, INSTALLED BY EC. 8 N 2. IF OPTIONAL TABLE TRACKER SYSTEM IS TO BE USED. IF USED, PROVIDE 2 #12 AND 1 #12 GROUND TO AVAILABLE SPARE 20A/lP BREAKER. CONNECT CIRCUIT TO (3) 5-20R W C4 O RECEPTACLES, (1) RECEPTACLE FOR MODEM/GATEWAY (TYPICALLY LOCATED BEHIND N VALENCE AT T-9" AFF), (1) RECEPTACLE FOR LOCATOR CHARGER (TYPICALLY LOCATED IN MANAGERS OFFICE) AND (1) RECEPTACLE FOR MONITOR (TYPICALLY LOCATED AT PICKUP COUNTER). COORDINATE EXACT LOCATION(S) IN THE FIELD. 3. COORDINATE LOCATION AND REQUIREMENTS OF HAPPY MEAL DISPLAY WITH DECOR COMPANY. TIE INTO LIGHTING CIRCUIT SERVING THIS AREA, 2 #12 AND 1 #12 E.G. IN 112" CONDUIT. 4. RELOCATED ORDERING KIOSK. COORDINATE EXACT LOCATION AND REQUIREMENTS WITH ARCHITECT AND OWNER PRIOR TO RELOCATIONS. EXTEND CIRCUITRY AND CONDUCTOR AS REQUIRED. VERIFY THAT EACH KIOSK IS POWERED BY A 1 POLE 20 N AMP CIRCUIT BREAKER. < 5. COORDINATE LOCATION AND REQUIREMENTS OF FUTURE CASH HANDLER WITH O DECOR COMPANY. POWER IS FED FROM ORDERING KIOSK BASE PLATE, IF NOT LOCATED NEXT TO THE WALL. IF LOCATED NEXT TO TO A WALL THEN FEED FROM Z WALL POWER. J 04 o04 6. COORDINATE LOCATION AND REQUIREMENTS OF J-BOX FOR DECOR ELEMENT WITH DECOR DRAWINGS. 2 #12 AND 1 #12 E.G. IN 112" CONDUIT. 7. CONNECT TO SPARE 20 AMP - 1 P, 120 VOLT BREAKER. FURNISH AND INSTALL BREAKER IF A SPARE IS NOT AVAILABLE. CONTRACTOR TO FIELD VERIFY CIRCUIT NUMBERS AND EXACT NUMBER OF SPARES AVAILABLE. SEE SHEET E3.0 FOR REQUIREMENTS THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY ADAM T. _ = M= RALE POWELL. PE USING A DIGITAL • SIGNATURE AND DATE. PRINTED COPIES ENGINEERING I N CL OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND 994 CUR IE DAVISDA I 9942 CURRIE DR. STE H., TAMPA, FL 33619 THE SIGNATURE MUST BE VERIFIED ON TEL ANY ELECTRONIC COPIES- WWW.EMERALDMEP.COM EEI PROJECT# 22072M W O :2 Ldaf U ". 0C O z W -C� - W WG 1802.31 E2e0 AA-0003276 • LOAD SUMMARY EXISTING MDP (1000 AMP MAIN BREAKER) EXISTING LOAD @ 125% PER NEC 220.87 Ll0,500 VA NEW ADDITIONAL LOAD 6,512 VANEW TOTAL 7,012 VA 7 AMPS) EXISTING PANEL "AP4" SQUARE D: NQ 208Y/120V, 30 4W VOLTAGEIPHASE 200A MLO 200A BUS NEMA-1 SURFACE CKT AMPS POLE - .. .. 2 20 1 SERIES RATED COPPER BUS SCUD NEUTRAL NOTES LOAD --- VA 600 CKT AMPS POLE DESCRIPTION NOTES LOAD VA DESCRIPTION EX ABS 1 3 20 20 1 1 EX REFRIG COUNTER EX SILVER KING 720 960 4 6 20 20 1 1 EX SMOTHEE - _ EX OJ MACHINE 1200 5 20 1 EX ABS IN CHASE 600 1200 7 30 2 EX SPECIALTY COFFEE 2246 8 20 1 EX INDOOR DIRECT 900 9 2246 10 20 1 EX RTI OUTLETS EX TOASTER 900 1813 1813 1813 11 13 20 1 EX SAFE EX TEA BREWER 120 2246 12 14 30 3 30 2 15 2246 16 17 30 2 - EX LOAD 2246 18 20 1 EX TIME CLOCK 120 19 2246 __-._ 1000 20 22 30 2 EX Q'ING WEN 1602 1602 21 20 1 - £X PRINTER -. 23 20 1 EX D/T 2 300 24 30 2 EX VIPER EXLOAD 1487 25 20 1 EX D/T 1 300 26 1487 27 20 1 BAKED GOODs/DCO 1 360 28 30 2 1487- 1487 29 31 20 20 1 1 REACH -IN REFRIG_ - 1,2 1,2 1356 30 BASE REFRIGERATOR 768 32 20 2 GING OVEN 1,2 1602 1602 33 20 1 FINISHING STATION 1,2 960 34 35 20 1 CASH RECYCLER 1 528 36 20 2 Q'ING WEN 1,2 1602 37 20 1 DELIVERY TABLETS 1 720 39 20 1 KVS/POS/STICKY LABEL 1 14 40 20 1 DINING RECEPTACLES 1 720 _- 41 20 1 HOT WATER DISPENSER 1,2_ NOTES: - -- _. _ __ -_ 1. NEW BREAKER TO MATCH TYPE AND AIC RATING OF EXISTING BREAKERS IN THIS PANEL. 184 42 20 1 DINING RECEPTACLES 1 900 _ _ LOAD G EC D MA D DE8CRIP ON ___ (VA), FA (VA} LIGHTING 0 0.00 0 HVAC - COOL 0'' 0.00 0 HVAC - HEAT 0 0.00 0 RECEPTACLE 10,372 0.98 10,186 MISC - 42,527 - 1.00_ -- 42,527 TOTAL 52,89952,713 -- 2. GFI BREAKER PER NEC 210.8 3. 4. 5. 8. TOTAL DEMAND CURRENT 0 208Y/120V 30 146.3 Alps ALL SINGLE-PHASE RECEPETACLES RATED 150 VOLTS TO GROUND OR LESS, 50 AMPERES OR LESS AND THREE-PHASE RECEPTACLES RATED 150 VOLTS TO GROUND OR LESS, 100 AMPERES OR LESS INSTALLED SHALL HAVE GROUND -FAULT CIRCUIT -INTERRUPTER PROTECTION FOR PERSONNEL. jRAI ELECTRICAL SYMBOL LEGEND SYMBOL DESCRIPTION JUNCTION BOX WITH TWO (2) DUPLEX (20A; 125V.) RECEPTACLES JUNCTION BOX WITH DUPLEX (20A; 125V.) RECEPTACLE O JUNCTION BOX ® JUNCTION BOX WITH SPECIAL PURPOSE ® JUNCTION BOX WITH ISOLATED GROUND RECEPTACLE TP TAMPER RESISTANT GFCI DUPLEX RECEPTACLE/USB COMBO MOUNTED AT 18" AFF. IN PUBLIC AREAS. EC SHALL PROVIDE PASS AND SEYMOUR "SAFELOCK" 2095-TR-' ("`" I -IVORY, W=WHITE, GRY=GRAY, BK=BLACK, RED=RED, LA=LIGHT ALMOND). SPECIFIED RECEPTACLE BECOMES DE - ENERGIZED UPON FAILURE OF GFI DEVICE. NO SUBSTITUTIONS. (TYPICAL) / \ RACEWAY CONCEALED IN WALL OR CEILINGS HOMERUN TO PANEL PB = Pullbox VIF =Verify in Field ELECTRICAL SCHEDULE JB =Junction Box EC = Electrical Contractor TAG # QTY DESCRIPTION VOLT/PH FLA BRK SIZE COND/WIRE PNUCCT RECEP TYPE HGT AFF REQUIREMENTS & REMARKS 004.20E6 1 MENU BOARD - DIGITAL 120/1 ISOLATED ISOLATED 2.6 20A 2 #12, 1 #12 IG AND 1 #12 EG - 1/2"C NOTE 1 IG5262 6-5" 004.20E7 1 FREESTANDING DIGITAL MERCHANDISER 120/1 2.6 20A 2 #12, 1 #12 IG AND NOTE 1 IG5262 CLG - ISOLATED 1 #12 EG - 1/2"C 1 DIGITAL MERCHANDISER - MEDIA PLAYER DATA CABLE - JB 6'-5" JB W/ 1" C. TO FULL HEIGHT WALL AND TO ABOVE CEILING W/ BUSHING FOR DATA CABLES. SUPPLY W/ GROMMETED OPENING IN COVER PLATE 1 BAKED GOODS DISPLAY CASE 120/1 1.5 20A 2 #12, 1 #12EG - 1/2"C AP4-27 5-15R SEE RMKS PROVIDE RECEP. IN COUNTER -MOUNTED RACEWAY E020.00E2 1 UTILITY CHASE DR BEVERAGE VERSION - - - - SEE RMKS CHASE AND RECEPTACLES BY KES 1 UTILITY CHASE D/T BOOTH - - SEE RMKS CHASE AND RECEPTACLES BY KES 1 AUTOMATED BEVERAGE SYSTEM 120/1 5.0 20A 2 #12, 1 #12EG - 1/2"C NOTE1 5-20R 2'-0" EC TO BRING POWER DOWN WALL, PROVIDE/INSTALL RECEPTACLE 1 AUTOMATED BEVERAGE SYSTEM DATA CABLE - - - - - SEE RMKS CABLE FURNISHED/INSTALLED BY POS INSTALLER 1 ABS PRECOOLER 120/1 14.9 20A 2 #12, 1 #12EG - 1/2"C NOTE 1 5-20R 3'-10" EC TO BRING POWER DOWN WALL, PROVIDEANSTALL RECEPTACLE 039.15E3 1 ICE MACHINE - 1000 LB 12011 1.1 15A 2 #12, 1 #12EG - 1/2"C NOTE 1 5-15R @ CLG CIRCUIT BREAKER SHALL BE HACR TYPE 041.09E1 1 ICE MACHINE REMOTE CONDENSER - 1000 LB 208/3 10.8 15A 3 #12, 1 #12EG - 1/2"C NOTE 1 SEE RMKS SEE RMKS EC TO PROVIDE WP 30A-3P NF DISC AT UNIT ON ROOF. CIRCUIT BRAKERS SHALL NE HACR TYPE. CONTROL WIRE TO ICE MACHINE LOCATION BY ACM 044.29E1 1 BREAKER PANEL 125 AMP - 3 PHASE EQUIPMENT MOUNTED 120-208/3 SEE RMKS 125A 4 #1, 1 #6 E.G. - 1 1/2-C NOTE 1 SEE RMKS EC TO EXTEND EXISTING SERVICE AS REQ & CONNECT TO PANEL 044.98E1 1 48" HLS TABLE 120/1 11.0 20A 2 #12, 1 #12EG -1/2"C 044.29E1 - SEE RMKS EC TO EXTEND CIRCUIT TO KES OUTLET TO CHASE 129.00E2 2 Q'ING OVEN 208/1 20 20A 2 #12, 1 #12EG - 112"C AP4-(32,34)(36,38) 6-20R 5'-6" PLUGS INTO OVERHEAD RECEPTACLE #32006W(B) PROVIDE BY KES HEIGHT TO BOTTOM OF RECEPTACLE 178.13E2 1 REACH -IN REFRIGERATOR - SINGLE WIDE 120/1 11.3 20A 2 #12, 1 #12EG - 1/2"C AP4-29 5-20R SEE RMKS EC TO BRING POWER DOWN CHASE AND CONNECT TO CHASE MOUNTED RECEPTACLE 207.09E1 1 30" BASE REFRIGERATOR 120/1 3.2 20A 2 #12, 1 #12EG - 1/2"C AP4-31 5-20R 2'-0" EC TO BRING POWER DOWN WALL, PROVIDE/INSTALL RECEPTALE 207.10E1 1 FINISHING STATION 120/1 8.0 20A 2 #12, 1 #12EG -1/2"C AP4-33 5-20R 2'-0" EC TO BRING POWER DOWN WALL, PROVIDEANSTALL RECEPTALE 207.11E4 1 BASE REFRIGERATOR 120/1 3.2 20A 2 #12, 1 #12EG - 1/2"C AP4-31 5-20R 2'-0" EC TO BRING POWER DOWN WALL, PROVIDE/INSTALL RECEPTALE 210.00E10 1 FUTURE CASH RECYCLER 120/1 ISOLATED 4.4 20A 2 #12, 1 #12 IG AND 1 #12 EG - 1/2"C AP4-35 (2) IG4700 SEE RMKS PROVIDE RECEPTACLE IN COUNTER -MOUNTED RACEWAY 211.00E6 2 DELIVERY TABLETS 12011 3.0 20A 2 #12, 1 #12EG - 1/2"C AP4-37 (2) 5-20P 5'-6" 213.00E10 1 TABLET BRACKET 120/1 ISOLATED 2.6 20A 2 #12, 1 #12 IG AND 1 #12 EG - 1/2"C NOTE 1 SEE RMKS SEE RMKS PROVIDE IG RECEPTACLE IN COUNTER -MOUNTED RACEWAY 213.00E11 1 TABLET BRACKET 120/1 ISOLATED 1.5 20A 2 #12, 1 #12 IG AND 1 #12 EG - 1/2"C SEE RMKS 5-20R SEE RMKS EXTEND NEARBY APPLIANCE PANEL CIRCUIT TO NEW RECEPTACLE 215.00E3 1 POS REGISTER - FRONT COUNTER DATA CABLE - - - - PB 10" EXTEND 2" CONDUIT TO ABOVE CEILING FOR POS DATA CABLES 215.00E12 1 POS REGISTER - FRONT COUNTER 120/1 ISOLATED 3.0 20A 2 #12, 1 #12 IG AND 1 #12 EG - 1/2"C NOTE 1 IG4700 SEE RMKS PROVIDE IG RECEPTACLE IN COUNTER -MOUNTED RACEWAY 215.00E15 1 POS REGISTER - FRONT COUNTER DATA CABLE - PB 10" EXTEND TWO 1" CONDUITS TO ABOVE CEILING FOR POS DATA CABLES 215.05E2 1 NEW KVS MONITOR DATA CABLE - - - - SEE RMKS CABLE FURNISHED AND INSTALLED BY POS SUPPLIER 215.05E3 1 NEW KVS MONITOR 120/1 ISOLATED 1.5 20A 2 #12, 1 #12 IG AND 1 #12 EG - 1/2"C AP4-39 IG4700 SEE RMKS DOWN CHASE, POS INSTALLER TO MAKE FINAL CONNECTIONS 215.07E1 1 POS REGISTER - DELIVERY 120/1 ISOLATED 3.0 20A 2 #12, 1 #12 IG AND 1 #12 EG - 1/2"C AP4-39 IG47GO 42" - 215.07E3 1 POS - KVS MONITOR - - - - - PB 42" EXTEND 2" CONDUIT TO ABOVE CEILING FOR POS DATA CABLES 216.00E2 2 POS - VIDEO MONITOR DATA CABLE - - - - - - CABLE FURNISHED/INSTALLED BY POS INSTALLER 216.00E3 1 POS - VIDEO MONITOR W/ SUPPORTS 120/1 ISOLATED 1.5 20A 2 #12, 1 #12 IG AND 1 #12 EG - 1/2"C AP4-39 IG4700 @ CLG EC TO PROVIDE/INSTALL RECEPTACLE, POS INSTALLER TO CONNECT POS 216.00E7 1 POS - VIDEO MONITOR W/ SUPPORTS tQ CHASE 120/1 ISOLATED 1.5 20A 2 #12, 1 #12 IG AND 1 #12 EG - 1/2"C AP4-39 IG4700 SEE RMKS EC TO BRING POWER DOWN CHASE AND CONNECT TO CHASE MOUNTED RECEPTACLE 216.00E11 1 POS - VIDEO MONITOR 120/1 ISOLATED 1.5 20A 2 #12, 1 #12 IG AND 1 #12 EG - 1/2"C AP4-39 IG4700 5'-6" CABLE PROVIDED AND INSTALLED BY POS SUPPLIER 216.00E12 1 POS - VIDEO MONITOR DATA CABLE - - - - 4x4x4 PB 5'-6" EXTEND 2" CONDUIT ABOVE CEILING. CABLE FURNISHED AND INSTALLED BY POS SYSTEM SUPPLIER 216.04E1 1 ORB MONITOR (MINI) & SCANNER 120/1 ISOLATED 1.5 20A 2 #12, 1 #12 IG AND 1 #12 EG - 1/2"C A124-39 (2) IG4700 V-6" 216.05E4 1 ORB MONITOR 120/1 ISOLATED 1.5 20A 2 #12, 1 #12 IG AND 1 #12 EG - 1/2"C NOTE 1 IG4700 8'-1" - 216.05E5 1 ORB MONITOR 120/1 ISOLATED 1.5 20A 2 #12, 1 #12 IG AND 1 #12 EG - 1/2"C NOTE 1 IG4700 B.A. JB W/ 1-1/2"C. TO TERMINATE ABOVE CEILING W/BUSHINGS FOR DATA CABLE SUPPLY W/ GROMMETED OPENING IN COVER PLATE. 217.00E1 3 PARKlROTATE/SERVE BUMP BAR DATA CABLE - - - - - SEE RMKS POS TO COORD W/ MCD O/O, RELCOATED EXIST AS REQUIRED 219.00E10 2 POS - RECEIPT PRINTER 120/1 ISOLATED 0.7 20A 2 #12, 1 #12 IG AND 1 #12 EG - 1/2"C NOTE 1 IG4700 SEE RMKS PROVIDE IG RECEPTACLE IN COUNTER -MOUNTED RACEWAY 219.02E2 3 CYT POS - RECEIPT PRINTER 120/1 ISOLATED 0.7 20A 2 #12, 1 #12 IG AND 1 #12 EG - 1/2"C NOTE 1 IG4700 TBD POS INSTALLER TO COORDINATE WITH MCD 219.05E3 1 STICKY LABEL PRINTER 120/1 ISOLATED 0.7 20A 2 #12, 1 #12 IG AND 1 #12 EG - 1/2"C AP4-39 IG4700 38" FOR DELIVERY STATION 700.09E1 1 ECONOMY OEP BOX W/ MOUNTING HARDWARE - - - - SEE RMKS CEILING MOUNTED 701.13E16 1 DCO - GENERAL PURPOSE 120/1 1.5 20A 2 #12, 1 #12EG - 1/2"C AP4-27 5-20P SEE RMKS PROVIDE RECEPTACLE IN COUNTER -MOUNTED RACEWAY 7000.12E2 1 HOT WATER DISPENSER 120/1 15.4 20A 2 #12, 1 #12EG - 1/2"C A134-41 5-20R SEE RMKS PLUGS INTO CENTER ISLAND BREAKER PANEL OR OUTLET HOUSING 8021.01 E2 3 RELOCATED COFFEE BREWER - - NOTE 1 - GC TO VERIFY AND REQORK ALL EXISTING UTILITIES AS REQUIRED 8021.10E2 1 RELOCATED SPECIALTY COFFEE - - - NOTE 1 - - GC TO VERIFY AND REQORK ALL EXISTING UTILITIES AS REQUIRED 8021.11E2 1 RELOCATED SMOOTHIE MACHINE - - NOTE 1 - GC TO VERIFY AND REQORK ALL EXISTING UTILITIES AS REQUIRED 8021.98E2 1 RELOCATED SUGAR DISPENSER - - NOTE 1 - - GC TO VERIFY AND REQORK ALL EXISTING UTILITIES AS REQUIRED 8023.05E2 2 RELOCATED CREAM DISPENSER - - - NOTE 1 - GC TO VERIFY AND REQORK ALL EXISTING UTILITIES AS REQUIRED 8024.01E1 1 RELOCATED ORANGE JUICE DISPENSER, DUAL FLAVO - - NOTE 1 - GC TO VERIFY AND REQORK ALL EXISTING UTILITIES AS REQUIRED 8025.02E2 1 RELOCATED ICED TEA BREWER - - - NOTE 1 - - GC TO VERIFY AND REQORK ALL EXISTING UTILITIES AS REQUIRED 8039.09E1 1 RELOCATED ICE MACHINE - - - - NOTE 1 - - GC TO VERIFY AND REQORK ALL EXISTING UTILITIES AS REQUIRED 8118.00E1 1 RELOCATED Q'ING OVEN - NOTE 1 - - GC TO VERIFY AND REQORK ALL EXISTING UTILITIES AS REQUIRED 8118.00E3 1 RELOCATED Q'ING OVEN - - NOTE 1 - - GC TO VERIFY AND REQORK ALL EXISTING UTILITIES AS REQUIRED 8118.00E5 1 RELOCATED Q'ING OVEN - - NOTE 1 - GC TO VERIFY AND REQORK ALL EXISTING UTILITIES AS REQUIRED 8122.27E1 1 RELOCATED HRT TOASTER NOTE 1 - - GC TO VERIFY AND REQORK ALL EXISTING UTILITIES AS REQUIRED 8131.02E1 1 RELOCATED BISCUIT OVEN - - - - NOTE 1 - GC TO VERIFY AND REQORK ALL EXISTING UTILITIES AS REQUIRED 8178.08E1 2 RELOCATED REACH -IN REFRIGERATOR - NOTE 1 - GC TO VERIFY AND REQORK ALL EXISTING UTILITIES AS REQUIRED 8181.01E2 1 RELOCATED REFRIGERATOR - SPECIALTY COFFEE - NOTE 1 GC TO VERIFY AND REQORK ALL EXISTING UTILITIES AS REQUIRED 8203.02E2 1 RELOCATED COMBO SHAKEISUNDAE MACHINE - - - NOTE 1 - - GC TO VERIFY AND REQORK ALL EXISTING UTILITIES AS REQUIRED 8205.11E2 1 RELOCATED FROZEN CARBONATED BEVERAGE - NOTE 1 - GC TO VERIFY AND REQORK ALL EXISTING UTILITIES AS REQUIRED 8207.09E1 1 RELOCATED BASE REFRIGERATOR - - - NOTE 1 - GC TO VERIFY AND REQORK ALL EXISTING UTILITIES AS REQUIRED 8215.05E2 4 RELOCATED KVS MONITOR - - - NOTE 1 - - GC TO VERIFY AND REQORK ALL EXISTING UTILITIES AS REQUIRED 8215.05E3 4 RELOCATED KVS MONITOR NOTE 1 - - GC TO VERIFY AND REQORK ALL EXISTING UTILITES AS REQUIRED 8215.98E1 1 RELOCATED POS PC HARDWARE - 2 BOOTH DIT - - - - NOTE 1 - - GC TO VERIFY AND REQORK ALL EXISTING UTILITIES AS REQUIRED 8215.98E2 2 RELOCATED POS PC HARDWARE - 2 BOOTH DIT - - NOTE 1 - - GC TO VERIFY AND REQORK ALL EXISTING UTILITIES AS REQUIRED 8216.00E2 2 RELOCATED POS - VIDEO MONITOR - - NOTE 1 - - GC TO VERIFY AND REQORK ALL EXISTING UTILITIES AS REQUIRED 8216.00E7 2 RELOCATED POS - VIDEO MONITOR @ CHASE - - - NOTE 1 - - GC TO VERIFY AND REQORK ALL EXISTING UTILITIES AS REQUIRED 8217.00E1 2 RELOCATED PARK/ROTATE/SERVE BUMP BAR - - - NOTE 1 - - GC TO VERIFY AND REQORK ALL EXISTING UTILITIES AS REQUIRED 8217.13E2 1 RELOCATED MERGE POINT MONITOR NOTE 1 - - GC TO VERIFY AND REQORK ALL EXISTING UTILITIES AS REQUIRED 8219.00E7 1 RELOCATED POS-RECEIPT PRINTER - - - - NOTE 1 - - GC TO VERIFY AND REQORK ALL EXISTING UTILITIES AS REQUIRED 8219.00E8 1 RELOCATED POS-RECEIPT PRINTER - - NOTE 1 - GC TO VERIFY AND REQORK ALL EXISTING UTILITIES AS REQUIRED 8327.00E1 1 RELOCATED PIE DISPLAY - NOTE 1 - - GC TO VERIFY AND REQORK ALL EXISTING UTILITIES AS REQUIRED NOTE: 1. USE EXISTING CIRCUITRY, CONTRACTOR TO VERIFY EXISTING CIRCUITS AND BREAKER SIZE. UPGRADE BREAKER AND CIRCUIT TO MATCH NEW EQUIPMENT REQUIREMENTS IF EXISTING CIRCUIT IS TOO SMALL. VERIFY EXISTING CIRCUIT NUMBERS AND RECORD ON AS -BUILT DRAWINGS FOR INSPECTORS REVIEW DURING ROUGH -IN INSPECTION. SEE SHEET E2.0 FOR REQUIREMENTS ELECTRICAL ROUGH -IN INFORMATION CONTRACTOR TO FIELD VERIFY CIRCUIT NUMBERS AND EXACT NUMBER OF SPARES AVAILABLE. mI8i Z O N O W G 1 • • R 0 �• •CD Lm^• • �c+ 0 • F o +>wt U• W • • • > +J d w ' • (� • • o N' z "' 'zi I IN 1: 1 Immi e � a.I�Ld THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY ADAM T. EMERALD ���� �2..3� POWELL, PE USING A DIGITAL SIGNATURE AND DATE. PRINTED COPIES E ENGINEERING I N Q OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND 994 CU IE DAVISDA DR. STE H., TAMPA, FL 33619 0 THE SIGNATURE MUST BE VERIFIED ON TEL ( 13) 99 00 !�! • ANY ELECTRONIC COPIES. WWW.EMERALDMEP.COM EEI PROJECT`* 22072M 8j - -------- mki 004. PULLBOX FOR DATA PROVIDED CONDW BY E.C. TO DOT LOCA71ON TO ALIGN WITH ADJACENT DECOR WALL PA ACCESS PANEL 0 TO ALLOW CABLE & CONDUIT ROUT INTERIOR ELEVATIONS 1 /2" = 1'-O" DATA CABLE CONTRACIOR 70 UTILIZE CONDUCKM 111 10111t011MI WrIN RETROFIT KIT 7O REIWEII RECEPTACLES WITHIN BASE. NNS7�t011Q. NEIIIIIIIIIIIIIIII � SIDE BY WE CASH HANDLER J8 WITH ONE (1) 1 1 /2- CONDUIT TO NOTES: 1. 7NI EI(AIIPLE IS FOR A SIDE BY SIDE CASH HANDLER 7HAT DOES NOT NAME A SC P1M.L NENINT WALL UNIND IT AND I NEXT 70 A KIOSK. AMA . SDE CASH HANDLER UTLEM 3 PLUGS AND ADDS 4.4 FUTURE 1 �4►� — pAr' • Y �.� MEDIA PLAM INSTALLED N SCREEN. NNI111111R TO MANLFACTLIAM INSTALLAXION omymxmm IF CEILING IS ABOIME 12' TALL, PROVIDE 105M FAMORACLE ADD J— = WITH i • CONDUIT 70 A11611iE CELM DffA CAN AT LOCA74ON SHOWN CASH HAN 1'-0" N07E& 1. DIGITAL MERCHANDISER CHANNELS ARE DESIGNED TO REACH UP 70 A 10' CEILING. IF CUM 0 TA MR EXTDrDER KIT CAN BE ORDEtRED 70 RUCH 1Z'. FUTURE CASH HANDLER POWER DETAIL 1/4" - 1'-0" POWER DETAIL NOTES 1❑ THIS SLIP SHEET IS PROVIDED FOR ELECTRICAL ROUGH -IN PREPARATION AND GENERAL DIGITAL MENU BOARD MOUNTING GUIDELINES, EVALUATE EXISTING VALANCE WALL STRUCTURE AND BACKING MATERIALS TO ENSURE ADEQUATE SUPPORT OF EQUIPMENT. (MALL HEADER AND WALL PENETRATIONS FOR CONDUITS OR OTHER ELECTRICAL ROUTING MUST BE SEALED TIGHT i • DMBIML MSUPPORT EQUIPMENT VINCLUDES: lALLiAllUN Ivu I ta: - NETWORK MANAGEMENT DEVICE (NMD) - 24 PORT ENHANCED WAYPORT SWITCH (EWS) THIS EQUIPMENT IS TYPICALLY MOUNTED IN TECHNOLOGY CLOSET OR IN MANAGER'S OFFICE. • DMB INSTALLERS TO ROUTE CONTROL WIRES FROM NMD/EWS ABOVE CEILING TO MENU BOARD VALANCE WALL. WIRES TO EXIT WALL VIA J-BOXES. • EACH DMB SECTION REQUIRES A DEDICATED MEDIA PLAYER. z 0 R 0 0 0 W C W 12 M N O — I ii I o k 11111//of up * &aa' NA. 0 CL Q. � RECESSED MENU BOARDS 9 THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY ADAM T. - = M = KPALD POWELL, PE USING A DIGITAL SIGNATURE AND DATE. PRINTED COPIES ENGINEERING I N a OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND 994TEL CU IE DAVISDA I gg42 CURRIE DR. STE H., TAMPA, FL 33619 THE SIGNATURE MUST BE VERIFIED ON Ij! ANY ELECTRONIC COPIES. WWW.EMERALDMEP.COM EEI PROJECT# 22072M LLJ 0 w '` w • ll .. s 2t 0 :R I m I I lial 1802.31 • 0 M-0003276 or w UP TO PHOTOCELL ON ROOF. , 0 LIGHTING FIXTURES MANUAL SWITCH (if shown on drawings) LOW VOLTAGE CABLE NOTES: 1. REFER TO LIGHTING PLAN FOR OCCUPANCY SENSOR LOCATIONS AND QUANTITIES. OCCUPANCY SENSOR CONTROL DETAIL LIGHTING FIXTURE SCHEDULE NOTES: 1. ORDER LED EXIT SIGNS WITH LETTER COLORS THAT COMPLY WITH LOCAL CODES FROM SECURITY LIGHTING. FOR RED LETTERS USE #PRB (UNIVERSAL) FOR GREEN LETTERS USE #PGB (UNIVERSAL) OR IF THE ABOVE EXIT SIGNS DO NOT COMPLY WITH LOCAL CODES USE, LED SIGN WITH BATTERY BACKUP, LETTER SIZE, COLOR, TYPE AND DIRECTIONAL ARROWS AS REQUIRED BY THE LOCAL AUTHORITIES. 2. BEFORE ORDERING VERIFY WITH LOCAL MUNICIPALITY THAT THIS FIXTURE COMPLIES WITH ANY LOCAL LIGHTING ORDINANCE. EMERGENCY LIGHTING NOTES: 1. CONNECT ALL EXIT SIGNS, EMERGENCY LIGHTS, INVERTER AND NIGHT LIGHTS TO THE EXISTING EXIT/EMERGENCY LIGHTING CIRCUIT. 2. CONNECT ALL EXIT SIGNS, EMERGENCY LIGHTS AND NIGHT LIGHTS TO ONE CIRCUIT BREAKER. 3. LIGHTING INDICATED WITH A "NL" ARE NIGHTLIGHTS AND SHALL BE CONNECTED TO THE UNSWITCHED LEG OF THE CIRCUIT. 4. EMERGENCY LIGHTING HAS BEEN DESIGNED PER NFPA 101 MAINTAIN 1 FC IN PATH OF EGRESS. IF FIELD CONDITIONS REQUIRE ANY CHANGES TO LIGHTING DESIGN, EMERGENCY LIGHTING, SHALL BE INSTALLED TO MEET THE ABOVE REQUIREMENTS. LIGHTING FIXTURE SCHEDULE SYMBOL DESCRIPTION MANUFACTURES CAT. NO. VOLTAGE LAMPS MOUNTING A LED DOWN RADIUS WALL SECURITY LIGHTING SYSTEMS NO: 14W WALL MOUNT E WALL WASHER SECURITY LIGHTING SYSTEMS NO.: 16 CEILING RECESSED ® SCONCE - SILVER FINISH RWSC-36LED-5K-DO-U-PS 120 RDA-60LM30-NF-S/RDA-60-H 120 SEE LIGHTING FIXTURE SCHEDULE NOTE NO. 2 LED CAN LIGHT SECURITY LIGHTING SYSTEMS NO.: 12W CEILING RECESSED F BLUE ROUND PENDANT SECURITY LIGHTING SYSTEMS NO.: 12 PENDANT HUNG B 0 RDA-136LM-30-FL-S/RDA-136-H 120 ® 7652 BLE-EQL-306-45358-1-LED 120 REFER TO DECOR DRAWINGS FOR EXACT FIXTURE TYPE LED CAN LIGHT FED FROM SECURITY LIGHTING SYSTEMS NO.: 12W CEILING RECESSED G SLIM PENDANT GREY LARGE SECURITY LIGHTING SYSTEMS NO.: 20 CEILING RECESSED BE O UNSWITCHED INVERTER PANEL RDA- 1 36LM-30-FL-S/RDA-1 36-H 120 6797-BPS-1388-71 120 NL FOR USE AS NIGHT LIGHT AND REFER TO DECOR DRAWINGS FOR EXACT FIXTURE EMERGENCY LIGHT. TYPE 2x4, LED LAY -IN PRISMATIC SECURITY LIGHTING SYSTEMS NO. 44W CEILING LAY -IN ACRYLIC LENS LCA'T24-3.`iHLG-EDU-W['-GK 120 ® COMBO WITH BATTERY BACK-UP 120 UNIT 2x4, LED LAY -IN PRISMATIC ACRYLIC SECURITY LIGHTING SYSTEMS NO 44W CLILJNG LAY -IN EMERGENCY BATTERY AND DUAL LITE 2-5W SURFACE TO WALL Ck LENS FED FROM UNSWITCHED LCAT24-35HLG-EDU-WP-GK 120 X 2 REMOTE HEAD EV4D-02L-0/EVODB 120 OR SOFFIT INVERTER PANEL FOR USE AS NIGHT WHEN CONNECTED TO TWO REMOTE HEADS NL LIGHT AND EMERGENCY LIGHT. (FOR SINGLE GANG JUNCTION BOX) DELIVERY POD LED LIGHT SECURITY LIGHTING SYSTEMS NO.: 9W CEILING RECESSED DENOTES EXISTING DEVICE TO DP LB4-61 D-30K-9-GD/IBX4QL-120 120 EX REMAIN (PROVIDED WITH DELIVERY POD) D 2 HEAD DOUBLE GIMBALL SECURITY LIGHTING SYSTEMS NO.: 14 CEILING RECESSED CEILING -MOUNTED LIGHTING INVERTER WITH MAINTENANCE FREE SEALED (MULTIPLE 25 DEGREE) GM2-120-LM-30-SBS 120 O LEAD CALCIUM BATTERY. 00 REFER TO DECOR DRAWINGS FOR EXACT FIXTURE SECURITY LIGHTING SYSTEMS LG1 SERIES TYPE INVERTER MAXIMUM OF FOUR 12.5 WATT CAN LIGHTS PER INVERTER DE 2 HEAD DOUBLE GIMBALL FED FROM SECURITY LIGHTING SYSTEMS NO.: 14 CEILING RECESSED m UNSWITCHED LIGHTING CIRCUIT GM2-120-LM-30-SBS 120 FOR USE AS NIGHT LIGHT AND REFER TO DECOR DRAWINGS FOR EXACT FIXTURE NL EMERGENCY LIGHT TYPE f Y OF ZEPFiY HILLS- );,-D;NG OFFICIAL_ LIGHTING PLAN SCALE: 1/4" = 1'-0" GENERAL NOTES 1. EC SHALL FIELD VERIFY THAT ALL LIGHT FIXTURES SHOWN ON THIS PLAN DO NOT OBSTRUCT OR CONFLICT WITH THE WORK OF OTHER TRADES. IF A DISCREPANCY IS FOUND, THE EC SHALL IMMEDIATELY NOTIFY THE GC BEFORE THE INSTALLATION OF SUCH FIXTURE(S)_. 2. IF PC-POS CASH REGISTER SYSTEM IS INSTALLED, RELOCATE FIXTURES ABOVE FRONT COUNTER TO AVOID GLARE ON THE CASH REGISTER SCREENS. INSTALL CABLE WHIP TO FIXTURES SO THAT FIXTURE CAN BE RELOCATED FOUR FEET WITHOUT DISCONNECTING CABLE WHIP. 3. THE USE OF "MC" CABLE WHERE PERMITTED BY LOCAL CODES WILL BE ALLOWED FOR ALL WIRING TO THE LIGHT FIXTURES. "ROMEX" & "BX" ARE NOT ACCEPTABLE. 4. LIGHTING FIXTURES AND LAMPS HAVE BEEN CHOSEN TO ACHIEVE MAXIMUM ENERGY CONSERVATION WHILE MAINTAINING ADEQUATE LEVELS OF ILLUMINATION. LAMP SPECIFICATIONS MUST BE STRICTLY FOLLOWED. ANY DEVIATION FROM LAMP SPECIFICATIONS MUST BE APPROVED IN WRITING BY McDONALD'S CORPORATION. 5. ALL BRANCH CIRCUIT WIRING TO 120 VOLT LIGHTING FIXTURES AND RECEPTACLES SHALL BE AS FOLLOWS. MAXIMUM LENGTH 85FT. - 2 #12, 1 #12 E_G. MAXIMUM LENGTH 140FT. - 2 #10, 1 #10 E.G. MAXIMUM LENGTH 225FT. - 2 #8, 1 #8 E.G. MAXIMUM LENGTH 350FT. - 2 #6, 1 #6 E.G_ 6. ALL EXTERIOR J-BOXES AND RECEPTACLES SHOWN ON THIS PLAN SHALL BE WATERPROOF. IF SIGNAGE DOES NOT COME WITH DISCONNECT SWITCH PROVIDE TOGGLE SWITCH WITH WEATHERPROOF COVER. ORDER ALL LIGHT FIXTURES FROM: SECURITY LIGHTING SYSTEMS, INC. PHONE: 1-800-LIGHT-IT EMAIL: QUOTATIONS@SECURITYLIGHTING.COM w i.-%rr_ VERIFY LIGHTING FIXTURE CATALOGUE NUMBERS WITH INTERIOR DESIGNER PRIOR TO ORDERING FIXTURES. 14 WP J-BOX FOR J McDONALDS } FASADE SIGN J O KEYNOTE LEGEND 1. CONNECT TO EXISTING CUSTOMER SERVICE LIGHTING CIRCUIT SERVING THIS AREA 2. CONNECT TO EXISTING DINING AREA LIGHTING CIRCUIT SERVING THIS AREA. 3. CONNECT TO THE EXISTING EXIT/EMERGENCY/NIGHT LIGHTING CIRCUIT. 4. EXISTING LIGHTING AND EMERGENCY LIGHTING IN THIS ARE TO REMAIN AS IS- 5- CONNECT TO EXISTING TOILET LIGHTING CIRCUIT THAT WAS MADE SPARE BY DEMOLITION. 6. PROVIDE CEILING MOUNTED ULTRASONIC OCCUPANCY SENSOR IN RESTROOMS (HUBBELL ATU500C). AIM SENSOR IN DIRECTION INDICATED BY ARROW FOR MAXIMUM COVERAGE OF ROOM. REFER TO OCCUPANCY SENSOR DETAIL ON THIS SHEET. ORDER ALL OCCUPANCY SENSORS FROM, SECURITY LIGHTING LIGHTING SYSTEMS, INC. 7. EACH RESTROOM HAS ONE SENSORS THAT CONTROL ALL LIGHTS TOGETHER AT ONCE IN RESPECTIVE RESTROOM. 8. CONNECT TO UNSWITCHED LEG OF THE RESTROOM LIGHTING CIRCUIT TO FEED INVERTER. 9. CONNECT TO EXISTING KITCHEN/SUPPORT AREA LIGHTING CIRCUIT SERVING THIS AREA. 10. CONNECT TO EXISTING PHOTOCELL EXTERIOR SECURITY LIGHTING CIRCUIT. 11. EC SHALL INSTALL AND CONFIGURE REMOTE EMERGENCY LIGHTING AT ALL EGRESS EXTERIOR DOORS FOR MAXIMUM ILLUMINATION AT POINTS OF EGRESS_ INSTALL WP J-BOX WITH IN SOFFIT TO ALLOW A FLUSH INSTALLATION OF ANY EXTERIOR EMERGENCY EGRESS LIGHTING (TYPICAL). 12. CONNECT TO EXISTING EXTERIOR LIGHTING WALL SCONCE CIRCUIT. 13. REFER TO ARCHITECTURAL ELEVATIONS FOR HEIGHTS AND LOCATIONS OF WALL SCONCE AND CANOPY DOWNLIGHTS. 14. EXISTING FRONT FASADE SIGN CIRCUIT. LOAD SUMMARY NO ADDITIONAL LOAD ADDED. LOADS ADDED ARE OFFSET BY LOADS REMOVED BY DEMOLITION LK • '• .�� Lr z co i zvv o� r 5 j1 V♦ �p ocv�CL © oo OGCOC 1p v♦ o�$C E 0O� THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY ADAM T. -� RALD � = POWELL, PE USING A DIGITAL SIGNATURE AND DATE. PRINKED COPIES ENGINEERING I N Q OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND D E 9942 CURRIAVIS DR. STE H., TAMPA, FL 33619 THE SIGNATURE MUST BE VERIFIED ON TEL ANY ELECTRONIC COPIES- WWW.FMFRAI.DMEP.COM EEI PR0IECT# 22072M W04 8 N ap b .72 0 OL Z w 0 O 2 :LLJ W z << t Z O 1802.31 E 1 0 • AA-0003276 PANEL AP4 EXISTING ELECTRICAL MDP, AP1, AP2 AND AP3 GENERAL NOTES: WIRE/RACEWAY: JEW EXISTING PANEL LP 1. ALL WORK SHALL BE IN ACCORDANCE WITH THE 2017 NATIONAL ELECTRICAL CODE 1. ALL CONDUCTORS SHALL BE COPPER, CONDUCTOR INSULATION SHALL BE DUAL TYPE AND SHALL ALSO COMPLY WITH ALL APPLICABLE RULES AND REGULATIONS OF LOCAL THHN/THWN 75-C. (167-F) FOR DRY, DAMP, AND WET LOCATIONS. CONDUCTOR AND STATE LAWS AND ORDINANCES. INSULATION WITH SINGLE TYPE MARKING THHN 90-C (194-F) MAY BE USED FOR DRY LOCATIONS ONLY. ALL CONDUCTORS SHALL BE COLOR CODED AS REQUIRED BY NEC 2. CONTRACTOR SHALL MAKE A THOROUGH EXAMINATION OF THE SITE AND THE AND FURTHER IDENTIFIED AND CODED AS SPECIFIED HEREINAFTER. COLOR CODING CONTRACT DOCUMENTS. NO CLAIM FOR EXTRA COMPENSATION WILL BE SHALL BE BY MEANS OF COLORED INSULATING MATERIAL, COLORED BRAID OR RECOGNIZED IF DIFFICULTIES ARE ENCOUNTERED WHICH AN EXAMINATION OF SITE JACKET OVER THE INSULATION OR BY MEANS OF SUITABLE COLORED, PERMANENT, CONDITIONS AND CONTRACT DOCUMENTS PRIOR TO EXECUTING CONTRACT WOULD NON -AGING, INSULATING TAPE APPLIED TO CONDUCTORS AT EACH CABINET OR HAVE REVEALED. JUNCTION POINT. THE COLOR CODING SHALL BE ACCOMPLISHED AS THE CONDUCTORS ARE INSTALLED. THE FOLLOWING SYSTEMS OF COLOR CODING SHALL 3. ELECTRICAL CONTRACTOR SHALL ARRANGE FOR ALL NECESSARY PERMITS, BE STRICTLY ADHERED TO: LICENSES, UTILITY COORDINATION AND INSPECTIONS AS REQUIRED BY THE CITY OR UTILITY COMPANY. OWNER WILL PAY FEES. CONTRACTOR IS RESPONSIBLE FOR ALL A) GROUND LEADS: GREEN EQUIPMENT REQUIRED BY UTILITY COMPANY AND SHOULD INCLUDE NECESSARY COSTS IN BID. B) 120/208 VOLT UNGROUNDED PHASE WIRES. - PHASE A: BLACK 4. CONTRACTOR SHALL LEGIBLY MARK-UP A SET OF 24"x36" DRAWINGS TO REFLECT PHASE B: RED AS -BUILT CONDITIONS AND TURN OVER TO THE ARCHITECT. PHASE C: BLUE NEUTRAL: WHITE 5. PANELBOARD MANUFACTURER SHALL PROVIDE ARC -FLASH WARNING LABELES FOR MDP AND ALL BRANCH PANELBOARDS IN ACCORDANCE WITH NEC 110. THE COLOR CODE ASSIGNED TO EACH PHASE WIRE SHALL BE CONSISTENTLY FOLLOWED THROUGHOUT GROUNDING: 2. ALL BRANCH CIRCUIT WIRING TO 120 VOLT LIGHTING FIXTURES AND RECEPTACLES SHALL BE AS FOLLOWS. 1. THE INTERIOR ELECTRICAL SYSTEMS SHALL BE COMPLETELY AND EFFECTIVELY MAXIMUM LENGTH 85FT. - 2 #12, 1 #12 E.G. GROUNDED AS REQUIRED BY NATIONAL ELECTRICAL CODE ALL METALLIC RACEWAYS MAXIMUM LENGTH 140FT. - 2 #10, 1 #10 E.G. SHALL BE MECHANICALLY AND ELECTRICALLY SECURE AT ALL JOINTS AND AT ALL MAXIMUM LENGTH 225FT. - 2 #8, 1 #8 E.G. BOXES, CABINETS, FITTINGS AND EQUIPMENT. MAXIMUM LENGTH 350FT. - 2 #6, 1 #6 E.G. OUTLET BOXES/DEVICES: 3. UNLESS OTHERWISE NOTED ALL CONDUCTORS SHALL BE RUN IN THIN WALL CONDUIT AND THIN WALL CONDUIT SHALL BE UNDERWRITERS' APPROVED GALVANIZED ELECTRICAL METALLIC TUBING. COUPLINGS AND CONNECTORS SHALL BE STEEL 1. ALL OUTLET BOXES SHALL BE RIGIDLY MOUNTED AND SHALL BE EQUIPPED WITH SET -SCREW TYPE, ZINC OR CADMIUM PLATED. MC CABLE MAY BE USED WHERE SUITABLE SCREW FASTENED COVERS. OPEN KNOCKOUTS OR HOLES IN BOXES CONCEALED IN WALLS. SHALL BE PLUGGED WITH SUITABLE BLANKING DEVICE. 4. ALL RACEWAYS SHALL BE PROPERLY ALIGNED, GROUPED, AND SUPPORTED BY 2. OUTLET BOXES SHALL BE 4 INCH SQUARE x 2-1/8" DEEP. OUTLET BOXES LOCATED MECHANICAL TYPE 'CADDY' CLIPS AT INTERVALS NOT EXCEEDING 8 FEET. ABOVE THE CEILING SHALL BE LEGIBLY IDENTIFIED WITH BRANCH CIRCUIT NUMBER OF CIRCUIT TERMINATED WITHIN BY MEANS OF BLACK PERMANENT MARKER. 5. ALL RACEWAYS WITH NO. 10 OR 12 AWG PHASE CONDUCTORS FOR RECEPTACLES, LIGHTING FIXTURES AND SIMILAR CIRCUITS SHALL BE PROVIDE WITH A PARITY SIZED GREEN EQUIPMENT GROUND CONDUCTOR. GROUND CONDUCTOR SHALL BE SWITCHGEAR: INSTALLED IN ENTIRE RACEWAY SYSTEM INCLUDING WALL SWITCHES AND FLEXIBLE CONDUIT TO LIGHT FIXTURES. EQUIPMENT GROUND CONDUCTOR SIZES FOR 1. PANELBOARD DIRECTORY CARDS SHALL BE TYPEWRITTEN WITH ACCURATE AND CIRCUITS WITH PHASE CONDUCTORS LARGER THAN NO. 12 AWG ARE INDICATED ON CURRENT INFORMATION BY THE CONTRACTOR AT THE END OF CONSTRUCTION. DRAWINGS. GROUND CONDUCTORS SHALL BE CONNECTED TO GROUND BUSS IN PANELBOARDS. 6. RACEWAY PENETRATIONS OF FIRE RATED WALLS AND/OR FLOORS SHALL BE SEALED TO MAINTAIN INTEGRITY OF CONSTRUCTION. ALL PRODUCTS, MATERIALS AND METHODS OF INSTALLATION SHALL BE UL APPROVED AND MEET NFPA. 7. ALL ELECTRICAL CONDUITS SHALL BE CONCEALED IN WALLS UNLESS AS -BUILT CONDITIONS PROHIBITS. GC TO NOTIFY ARCH/ACM OF AS -BUILT CONDITIONS. POWER PLAN SCALE: 1/4" = 1'-0" O KEYNOTE LEGEND 1. RACEWAY KIT PROVIDED WITH COUNTER, INSTALLED BY EC. 2- IF OPTIONAL TABLE TRACKER SYSTEM IS TO BE USED. IF USED, PROVIDE 2 #12 AND 1 #12 GROUND TO AVAILABLE SPARE 20A/l P BREAKER. CONNECT CIRCUIT TO (3) 5-20R RECEPTACLES, (1) RECEPTACLE FOR MODEM/GATEWAY (TYPICALLY LOCATED BEHIND VALENCE AT T-9" AFF), (1) RECEPTACLE FOR LOCATOR CHARGER (TYPICALLY LOCATED IN MANAGERS OFFICE) AND (1) RECEPTACLE FOR MONITOR (TYPICALLY LOCATED AT PICKUP COUNTER). COORDINATE EXACT LOCATION(S) IN THE FIELD. 3. COORDINATE LOCATION AND REQUIREMENTS OF HAPPY MEAL DISPLAY WITH DECOR COMPANY. TIE INTO LIGHTING CIRCUIT SERVING THIS AREA, 2 #12 AND 1 #12 E.G. IN 1/2" CONDUIT. 4_ RELOCATED ORDERING KIOSK. COORDINATE EXACT LOCATION AND REQUIREMENTS WITH ARCHITECT AND OWNER PRIOR TO RELOCATIONS. EXTEND CIRCUITRY AND CONDUCTOR AS REQUIRED. VERIFY THAT EACH KIOSK IS POWERED BY A 1 POLE 20 AMP CIRCUIT BREAKER. 5, COORDINATE LOCATION AND REQUIREMENTS OF FUTURE CASH HANDLER WITH DECOR COMPANY. POWER IS FED FROM ORDERING KIOSK BASE PLATE, IF NOT LOCATED NEXT TO THE WALL. IF LOCATED NEXT TO TO A WALL THEN FEED FROM WALL POWER. 6. COORDINATE LOCATION AND REQUIREMENTS OF J-BOX FOR DECOR ELEMENT WITH DECOR DRAWINGS. 2 #12 AND 1 #12 E.G. IN 1/2" CONDUIT. 7. CONNECT TO SPARE 20 AMP - 1 P, 120 VOLT BREAKER. FURNISH AND INSTALL BREAKER IF A SPARE IS NOT AVAILABLE. CONTRACTOR TO FIELD VERIFY CIRCUIT NUMBERS AND EXACT NUMBER OF SPARES AVAILABLE. I I I I I I I I 1 I � I I I � I E7, SEE SHEET E3.0 FOR REQUIREMENTS z O F d U N w 0 z 0 0 0 W O W (n W N M a o � U' • E o O c • • r E p E L ^ O • • al ca a - O � � U w S THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY ADAM T. _� � ���� � POWELL, PE USING A DIGITAL SIGNATURE AND DATE. PRINTED COPIES ENGINEERING I N Q OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND 9942 CURRIE DAVIS DR. STE H., TAMPA, FL 33619 THE SIGNATURE MUST BE VERIFIED ON TEL (813) 995-0300 ANY ELECTRONIC COPIES. WWW.EMERALDMEP.COM EEI PROJECT# 22072M N W � � g0 a Q Q 0 Of I � � Ld *z 0 0 Ld z Milo n 0 z 1802.31 E2oO AA-0003276 a m LOAD SUMMARY EXISTING MDP (1000 AMP MAIN BREAKER) EXISTING LOAD @ 125% PER NEC 220.87 180,500 VA NEW ADDITIONAL LOAD 16,512 VA NEW TOTAL 197,012 VA (547 AMPS) Z O EXISTING Z O O W 0 W 12 N 0 y w �4ti1 rlr�/��, ._ fi Q u�- `. _ 1 ��R rir • • t? U• . • O • m a� L .. I. ao + U' • C M >1 .Q • = EXISTING 'Z3 w U• $ °W �• •zM a <c (Z ��� " J J� ; a all -1 co B o O 5 N NOTE: 1. USE EXISTING CIRCUITRY, CONTRACTOR TO VERIFY EXISTING CIRCUITS AND BREAKER SIZE. UPGRADE BREAKER AND CIRCUIT TO MATCH NEW EQUIPMENT CONTRACTOR TO FIELD VERIFY CIRCUIT NUMBERS REQUIREMENTS IF EXISTING CIRCUIT IS TOO SMALL. VERIFY EXISTING CIRCUIT NUMBERS AND RECORD ON AS -BUILT DRAWINGS FOR INSPECTORS REVIEW AND EXACT NUMBER OF SPARES AVAILABLE. g DURING ROUGH -IN INSPECTION. O ALL SINGLE-PHASE RECEPETACLES RATED 150 VOLTS Ld M TO GROUND OR LESS, 50 AMPERES OR LESS AND SEE SHEET E2.0 THREE-PHASE RECEPTACLES RATED 150 VOLTS TO FOR REQUIREMENTS 0 o GROUND OR LESS, 100 AMPERES OR LESS INSTALLED ' THIS ITEM HAS BEEN ELECTRONICALLY ���� SHALL HAVE GROUND -FAULT CIRCUIT -INTERRUPTER S1POWELL"PEU3IJGADIGTALT _M= 1e02.31 PROTECTION FOR PERSONNEL. ELECTRICAL ROUGH -IN INFORMATION SIGNATURE AND DATE. PRINTED COPIES ENGINEERING LNG, OF THIS DOCUMENT ARE NOT 9942 CURRIE DAVIS DR. STE H., TAMPA, FL 33619 CONSIDERED SIGNED AND SEALED AND TEL (813) 995-0300 !�! • THE SIGNATURE MUST BE VERIFIED ON �j 0 ANY ELECTRONIC COPIES. WWW.EMERALDMEP.COM EEI PROJECT* 22072M M-WO3276 PANEL "AP1" SIEMENS 208Y/120V, 3QJ, 4W VOLTAGE/PHASE 225A MLO 225A BUS NEMA-1 MODULAR SERIES RATED COPPER Bus SOLID NEUTRAL CKT AMPS POLE 1 DESCRIPTION NOTES LQVAAD CKT AMPS POLE DESCRIPTION I,p�g LOAD 1 3 20 Ex SALAD CASE 1224 2 20 1 1 EX a/HOT cHocoLATE 1440 0 20 1 EX BEVERAGE BAR RECEPT 360 2246 4 20 SPARE 5 30 2 EX ABS MACHINE 6 30 2 EX BLUE REAR OEP 2246 7 2246 8 2246 9 20 1 IX ICE DISP BEVERAGE BAR 132 10 20 2 EX BLUE REAR OEP 1602 11 20 1 IX ICE DISP BEVERAGE BAR 132 12 1602 13 20 1 DINING DECOR ELEMENT 1 600 14 20 1 EX FRY DISP 720 15 30 2 FJ( BLUE REAR OEP 2246 16 20 1 EX YELLOW REAR OEP 480 17 2246 18 20 1 IX FRY BAGGING STATION 1884 19 1602 20 20 1 IX PANEL "AP4" SQUARE D: NQ 208Y/120V, 3QJ, 4W VOLTAGEJPHASE 200A MLO 200A BUS NEMA-1 SURFACE CKT AMPS POLE 2 20 1 SERIES RATED COPPER Bus SOLID NEUTRAL NOTES L� 600 CKT AMPS POLE DESCRIPTION EX REFPoG COUNTER NOTES LVQ4AD DESCRIPTION EX ABS EX SMDTHEE 1 20 1 720 3 20 1 Ex. SILVER KING 960 4 6 20 ZO 1 1 1200 1200 5 20 1 EX ABS IN CHASE 600 EX OJ MACHINE 7 30 2 EX SPECIALTY COFFEE Ex SAFE 2246 8 20 1 EX INDOOR DIRECT 900 9 2246 10 20 1 EX RTl OUTLETS EX TOASTER EX TIME CLOCK 900 1813 11 13 20 30 1 2 120 2246 12 30 3 IX TEA BREWER 14 1813 1813 120 15 2246 16 17 30 2 EX LOAD EX PRINTER 2246 2246 18 20 20 30 1 2 19 FJCQINGOVEN 1602 21 20 1 1000 22 1602 23 20 1 EX DTT 2 300 24 � 2 EX VIPER Ex LOAD Q'ING OVEN 1487 25 20 1 Ex,DtT_1_ - BAKED G000sroco 1 300 26 1487 1487 27 29 20 20 1 1 360 1356 28 30 � 2 REACH -IN REFRIG - 1,2 1487 1602 31 33 20 -_- 20 1 _ 1 BASE REFRIGERATOR 1 2 768 960 32 - 34 20 2 t,2 FINISHING STATION CASH RECYCLER 1,2 1 1602 1602 35 20 1 528 36 20 Z Q'INGOVEN 1,2 37 20 1 DELIVERY TABLETS 1 720 38 20 1 KVS/PO61ST1CKY LABEL t 41 20 1 HOT WATER DISPENSER 1,2 _ NOTES: IDESCRIP 1 • NEW BREAKER TO MATCH TYPE AND AIC RATING OF EXISTING BREAKERS IN THIS PANEL. 134 40 20 1 DINING__RECEPTACLES 1 720 1 DINING RECEPTACLES 1 900 LOAD EC D MA D 184 "CND(VA -_- FA LIGHTING 0 0.00 0 HVAC -COOL 0 0.00 0 HVAC -HEAT 0 0.00 0 RECEPTACLE 10, 372 0.98 10,186 MISC _ 42,527 1.00 42,527 TOTAL 52, 899 52, 713 2. GFI BREAKER PER NEC 210.8 3. q_ 5. 8. TOTAL DEMAND CURRENT 208Y/120V 30 146.3-AMPS ELECTRICAL SYMBOL LEGEND SYMBOL DESCRIPTION JUNCTION BOX WITH TWO (2) DUPLEX (20A; 125V.) RECEPTACLES JUNCTION BOX WITH DUPLEX (20A; 125V.) RECEPTACLE Q JUNCTION BOX ® JUNCTION BOX WITH SPECIAL PURPOSE ® JUNCTION BOX WITH ISOLATED GROUND RECEPTACLE TP TAMPER RESISTANT GFCI DUPLEX RECEPTACLE/USB COMBO MOUNTED AT 18" AFF. IN PUBLIC AREAS. EC SHALL PROVIDE PASS AND SEYMOUR "SAFELOCK" 2095-TR--'` (""" I -IVORY, W=WHITE, GRY=GRAY, BK=BLACK, RED=RED, LA=LIGHT ALMOND). SPECIFIED RECEPTACLE BECOMES DE - ENERGIZED UPON FAILURE OF GFI DEVICE. NO SUBSTITUTIONS. (TYPICAL) RACEWAY CONCEALED IN WALL OR CEILINGS HOMERUN TO PANEL PB = Pullbox VIF =Verify in Field ELECTRICAL SCHEDULE JB =Junction Box EC =Electrical Contractor TAG # QTY DESCRIPTION VOLT/PH FLA BRK SIZE COND/WIRE PNUCCT RECEP TYPE HGT AFF REQUIREMENTS &REMARKS 004.20E6 1 MENU BOARD -DIGITAL 120/1 2.6 20A 2 #12, 1 #12 IG AND NOTE 1 IG5262 6'-5" ISOLATED 1 #12 EG - 1/2"C 004.20E7 1 FREESTANDING DIGITAL MERCHANDISER 120/1 2.6 20A 2 #12, 1 #12 IG AND NOTE 1 IG5262 CLG - ISOLATED 1 #12 EG - 1/2"C 004.23E2 1 DIGITAL MERCHANDISER -MEDIA PLAYER DATA CABLE - - JB 6'-5" JB W/ 1" C. TO FULL HEIGHT WALL AND TO ABOVE CEILING W/ BUSHING FOR DATA CABLES. SUPPLY W/ GROMMETED OPENING IN COVER PLATE 012.03E2 1 BAKED GOODS DISPLAY CASE 12011 1.5 20A 2 #12, 1 #12EG - 1/2"C AP4-27 5-15R SEE RMKS PROVIDE RECEP. IN COUNTER -MOUNTED RACEWAY 009.14E1 1 UTILITY CHASE DR BEVERAGE VERSION - - - - SEE RMKS CHASE AND RECEPTACLES BY KES 009.15E1 1 UTILITY CHASE DR BOOTH - - - - SEE RMKS CHASE AND RECEPTACLES BY KES 020.00E2 1 AUTOMATED BEVERAGE SYSTEM 12011 5.0 20A 2 #12, 1 #12EG - 1/2"C NOTE 1 5-20R 2' -VA 0 " EC TO BRING POWER DOWN WALL, PROVIDE/INSTALL RECEPTACLE 020.00E3 1 AUTOMATED BEVERAGE SYSTEM DATA CABLE - - - - - SEE RMKS CABLE FURNISHED/INSTALLED BY POS INSTALLER 020.99E2 1 ABS PRECOOLER 120/1 14.9 20A 2 #12, 1 #12EG - 1/2"C NOTE 1 5-20R 3'-10" EC TO BRING POWER DOWN WALL, PROVIDE/INSTALL RECEPTACLE 039.15E3 1 ICE MACHINE - 1000 LB 120/1 1.1 15A 2 #12, 1 #12EG - 1/2"C NOTE 1 5-15R � CLG CIRCUIT BREAKER SHALL BE HACR TYPE 041.09E1 1 ICE MACHINE REMOTE CONDENSER - 1000 LB 208/3 10.8 15A 3 #12, 1 #12EG -1/2•C NOTE 1 SEE RMKS SEE RMKS EC TO PROVIDE WP 30A-3P NF DISC AT UNIT ON ROOF. CIRCUIT BRAKERS SHALL NE HACR TYPE. CONTROL WIRE TO ICE MACHINE LOCATION BY ACM 044.29E1 1 BREAKER PANEL 125 AMP - 3 PHASE 120-208/3 SEE RMKS 125A 4 #1, 1 #6 E.G. - 1 1/2"C NOTE 1 - SEE RMKS EC TO EXTEND EXISTING SERVICE AS REQ 8 CONNECT TO PANEL EQUIPMENT MOUNTED 044.98E1 1 48" HLS TABLE 120/1 11.0 20A 2 #12, 1 #12EG - 1!2"C 044.29E1 - SEE RMKS EC TO EXTEND CIRCUIT TO KES OUTLET TO CHASE 129.00E2 2 Q'ING OVEN 208/1 20 20A 2 #12, 1 #12EG - 1/2"C AP4-(32,34)(36,38) 6-20R 5'-6" PLUGS INTO OVERHEAD RECEPTACLE #32006W(B) PROVIDE BY KES HEIGHT TO BOTTOM OF RECEPTACLE 178.13E2 1 REACH -IN REFRIGERATOR -SINGLE WIDE 120/1 11.3 20A 2 #12, 1 #12EG - 1!2"C AP4-29 5-20R SEE RMKS EC TO BRING POWER DOWN CHASE AND CONNECT TO CHASE MOUNTED RECEPTACLE 207.09E1 1 30" BASE REFRIGERATOR 120/1 3.2 20A 2 #12, 1 #12EG - 1/2"C AP4-31 5-20R 2'-0" EC TO BRING POWER DOWN WALL, PROVIDE/INSTALL RECEPTALE 207.10E1 1 FINISHING STATION 120/1 8.0 20A 2 #12, 1 #12EG - 1/2"C AP4-33 5-20R 2'-0" EC TO BRING POWER DOWN WALL, PROVIDE/INSTALL RECEPTALE 207.11E4 1 BASE REFRIGERATOR 120/1 3.2 20A 2 #12, 1 #12EG - 1/2"C AP4-31 5-20R 2'-0" EC TO BRING POWER DOWN WALL, PROVIDE/1NSTALL RECEPTALE 210.00E10 1 FUTURE CASH RECYCLER 120/1 4.4 20A 2 #12, 1 #12 IG AND AP4-35 (2) IG4700 SEE RMKS PROVIDE RECEPTACLE IN COUNTER -MOUNTED RACEWAY ISOLATED 1 #12 EG - 1/2"C 211.00E6 2 DELIVERY TABLETS 120/1 3.0 20A 2 #12, 1 #12EG - 1!2"C AP4-37 (2) 5-20P 5'-6" - 213.00E10 1 TABLET BRACKET 120/1 2.6 20A 2 #12, 1 #12 IG AND NOTE 1 SEE RMKS SEE RMKS PROVIDE IG RECEPTACLE IN COUNTER -MOUNTED RACEWAY ISOLATED 1 #12 EG - 1/2"C 213.00E11 1 TABLET BRACKET 120/1 1.5 20A 2 #12, 1 #12 IG AND SEE RMKS 5-20R SEE RMKS EXTEND NEARBY APPLIANCE PANEL CIRCUIT TO NEW RECEPTACLE ISOLATED 1 #12 EG - 1/2"C 215.00E3 1 POS REGISTER -FRONT COUNTER DATA CABLE - - - - PB 10" EXTEND 2" CONDUIT TO ABOVE CEILING FOR POS DATA CABLES 215.00E12 1 POS REGISTER -FRONT COUNTER 120/1 3.0 20A 2 #12, 1 #12 IG AND NOTE 1 IG4700 SEE RMKS PROVIDE IG RECEPTACLE IN COUNTER -MOUNTED RACEWAY ISOLATED 1 #12 EG - 1/2"C 215.00E15 1 POS REGISTER -FRONT COUNTER DATA CABLE - - - PB 10" EXTEND TWO 1" CONDUITS TO ABOVE CEILING FOR POS DATA CABLES 215.05E2 1 NEW KVS MONITOR DATA CABLE - - - - - SEE RMKS CABLE FURNISHED AND INSTALLED BY POS SUPPLIER 215.05E3 1 NEW KVS MONITOR 120/1 1.5 20A 2 #12, 1 #12 IG AND AP4-39 IG4700 SEE RMKS DOWN CHASE, POS INSTALLER TO MAKE FINAL CONNECTIONS ISOLATED 1 #12 EG - 1/2"C 215.07E1 1 POS REGISTER -DELIVERY 120/1 3.0 20A 2 #12, 1 #12 IG AND AP4-39 IG4700 42" ISOLATED 1 #12 EG - 1/2"C 215.07E3 1 POS - KVS MONITOR - - - - PB 42" EXTEND 2" CONDUIT TO ABOVE CEILING FOR POS DATA CABLES 216.00E2 2 POS -VIDEO MONITOR DATA CABLE - - - - - - CABLE FURNISHED/INSTALLED BY POS INSTALLER 216.00E3 1 POS -VIDEO MONITOR W/ SUPPORTS 120/1 1.5 20A 2 #12, 1 #12 IG AND AP4-39 IG4700 � CLG EC TO PROVIDE/INSTALL RECEPTACLE, POS INSTALLER TO CONNECT POS ISOLATED 1 #12 EG - 1/2"C 216.00E7 1 POS -VIDEO MONITOR W/ SUPPORTS (a� CHASE 120/1 1.5 20A 2 #12, 1 #12 IG AND AP4-39 IG4700 SEE RMKS EC TO BRING POWER DOWN CHASE AND CONNECT TO CHASE MOUNTED ISOLATED 1 #12 EG - 1/2"C RECEPTACLE 216.00E11 1 POS -VIDEO MONITOR 120/1 1.5 20A 2 #12, 1 #12 IG AND AP4-39 IG4700 5'-0" CABLE PROVIDED AND INSTALLED BY POS SUPPLIER ISOLATED 1 #12 EG - 1/2"C 216.00E12 1 POS -VIDEO MONITOR DATA CABLE - - - 4x4x4 PB 5'-8" EXTEND 2" CONDUIT ABOVE CEILING. CABLE FURNISHED AND INSTALLED BY POS SYSTEM SUPPLIER 216.04E1 1 ORB MONITOR (MINI) 8 SCANNER 120/1 1.5 20A 2 #12, 1 #12 IG AND AP4-39 (2) IG4700 1'-6" - ISOLATED 1 #12 EG - 1/2"C 218.05E4 1 ORB MONITOR 120/1 1.5 20A 2 #12, 1 #12 IG AND NOTE 1 IG4700- ISOLATED 1 #12 EG - 1/2"C 216.05E5 1 ORB MONITOR 120/1 1.5 20A 2 #12, 1 #12 IG AND NOTE 1 IG4700 8'-1" JB W/ 1-1/2"C. TO TERMINATE ABOVE CEILING W/BUSHINGS FOR DATA CABLE ISOLATED 1 #12 EG - 1/2"C SUPPLY W/ GROMMETED OPENING IN COVER PLATE. 217.00E1 3 PARK/ROTATE/SERVE BUMP BAR DATA CABLE - - - - - SEE RMKS POS TO COORD W/ MCD O/O, RELCOATED EXIST AS REQUIRED 219.00E10 2 POS -RECEIPT PRINTER 120/1 0.7 20A 2 #12, 1 #12 IG AND NOTE 1 IG4700 SEE RMKS PROVIDE IG RECEPTACLE IN COUNTER -MOUNTED RACEWAY ISOLATED 1 #12 EG - 1/2"C 219.02E2 3 CYT POS -RECEIPT PRINTER 120/1 0.7 20A 2 #12, 1 #12 IG AND NOTE 1 IG4700 TBD POS INSTALLER TO COORDINATE WITH MCD ISOLATED 1 #12 EG - 1/2"C 219.05E3 1 STICKY LABEL PRINTER 120/1 0.7 20A 2 #12, 1 #12 IG AND AP4-39 IG4700 38" FOR DELIVERY STATION ISOLATED 1 #12 EG - 1/2"C 700.09E1 1 ECONOMY OEP BOX W/ MOUNTING HARDWARE - - SEE RMKS CEILING MOUNTED 701.13E16 1 DCO -GENERAL PURPOSE 120/1 1.5 20A 2 #12, 1 #12EG - 1/2"C AP4-27 5-20P SEE RMKS PROVIDE RECEPTACLE IN COUNTER -MOUNTED RACEWAY 7000.12E2 1 HOT WATER DISPENSER 120/1 15.4 20A 2 #12, 1 #12EG - 1/2'C AP4-41 5-20R SEE RMKS PLUGS INTO CENTER ISLAND BREAKER PANEL OR OUTLET HOUSING 8021.01E2 3 RELOCATED COFFEE BREWER - NOTE 1 - GC TO VERIFY AND REQORK ALL EXISTING UTILITES AS REQUIRED 8021.10E2 1 RELOCATED SPECIALTY COFFEE - - NOTE 1 - - GC TO VERIFY AND REQORK ALL EXISTING UTILITES AS REQUIRED 8021.11E2 1 RELOCATED SMOOTHIE MACHINE - - NOTE 1 - GC TO VERIFY AND REQORK ALL EXISTING UTILITES AS REQUIRED 8021.98E2 1 RELOCATED SUGAR DISPENSER - - - NOTE 1 - - GC TO VERIFY AND REQORK ALL EXISTING UTILITES AS REQUIRED 8023.05E2 2 RELOCATED CREAM DISPENSER - - - - NOTE 1 - - GC TO VERIFY AND REQORK ALL EXISTING UTILITES AS REQUIRED 8024.01E1 1 RELOCATED ORANGE JUICE DISPENSER, DUAL FLAVO - - NOTE 1 - GC TO VERIFY AND REQORK ALL EXISTING UTILITES AS REQUIRED 8025.02E2 1 RELOCATED ICED TEA BREWER - - - NOTE 1 GC TO VERIFY AND REQORK ALL EXISTING UTILITES AS REQUIRED 8039.09E1 1 RELOCATED ICE MACHINE - - - NOTE 1 - GC TO VERIFY AND REQORK ALL EXISTING UTILITES AS REQUIRED 8118.00E1 1 RELOCATED Q'ING OVEN - - - NOTE 1 - GC TO VERIFY AND REQORK ALL EXISTING UTILITES AS REQUIRED 8118.00E3 1 RELOCATED Q'ING OVEN - - - NOTE 1 - GC TO VERIFY AND REQORK ALL EXISTING UTILITES AS REQUIRED 8118.00E5 1 RELOCATED Q'ING OVEN - - - NOTE 1 - GC TO VERIFY AND REQORK ALL EXISTING UTILITES AS REQUIRED 8122.27E1 1 RELOCATED HRT TOASTER - NOTE 1 GC TO VERIFY AND REQORK ALL EXISTING UTILITES AS REQUIRED 8131.02E1 1 RELOCATED BISCUIT OVEN - - - NOTE 1 - GC TO VERIFY AND REQORK ALL EXISTING UTILITES AS REQUIRED 8178.08E1 2 RELOCATED REACH -IN REFRIGERATOR - - - NOTE 1 - - GC TO VERIFY AND REQORK ALL EXISTING UTILITES AS REQUIRED 8181.01 E2 1 RELOCATED REFRIGERATOR -SPECIALTY COFFEE - NOTE 1 - - GC TO VERIFY AND REQORK ALL EXISTING UTILITES AS REQUIRED 8203.02E2 1 RELOCATED COMBO SHAKE/SUNDAE MACHINE - - - - NOTE 1 - - GC TO VERIFY AND REQORK ALL EXISTING UTILITES AS REQUIRED 8205.11E2 1 RELOCATED FROZEN CARBONATED BEVERAGE - - - NOTE 1 - GC TO VERIFY AND REQORK ALL EXISTING UTILITES AS REQUIRED 8207.09E1 1 RELOCATED BASE REFRIGERATOR - - - NOTE 1 - - GC TO VERIFY AND REQORK ALL EXISTING UTILITES AS REQUIRED 8215.05E2 4 RELOCATED KVS MONITOR - - - NOTE 1 GC TO VERIFY AND REQORK ALL EXISTING UTILITES AS REQUIRED 8215.05E3 4 RELOCATED KVS MONITOR - - NOTE 1 GC TO VERIFY AND REQORK ALL EXISTING UTILITES AS REQUIRED 8215.98E1 1 RELOCATED POS PC HARDWARE - 2 BOOTH DR - - NOTE 1 - GC TO VERIFY AND REQORK ALL EXISTING UTILITES AS REQUIRED 8215.98E2 2 RELOCATED POS PC HARDWARE - 2 BOOTH DR - - - - NOTE 1 - - GC TO VERIFY AND REQORK ALL EXISTING UTILITES AS REQUIRED 8216.00E2 2 RELOCATED POS -VIDEO MONITOR - - - NOTE 1 - - GC TO VERIFY AND REQORK ALL EXISTING UTILITES AS REQUIRED 8218.00E7 2 RELOCATED POS -VIDEO MONITOR � CHASE - - - NOTE 1 - GC TO VERIFY AND REQORK ALL EXISTING UTILITES AS REQUIRED 8217.00E1 2 RELOCATED PARK/ROTATE/SERVE BUMP BAR - - - - NOTE 1 - - GC TO VERIFY AND REQORK ALL EXISTING UTILITES AS REQUIRED 8217.13E2 1 RELOCATED MERGE POINT MONITOR - - NOTE 1 - GC TO VERIFY AND REQORK ALL EXISTING UTILITES AS REQUIRED 8219.00E7 1 RELOCATED POS-RECEIPT PRINTER - - - - NOTE 1 - GC TO VERIFY AND REQORK ALL EXISTING UTILITES AS REQUIRED 8219.00E8 1 RELOCATED POS-RECEIPT PRINTER - - NOTE 1 - GC TO VERIFY AND REQORK ALL EXISTING UTILITES AS REQUIRED 8327.00E1 1 RELOCATED PIE DISPLAY - NOTE 1 - GC TO VERIFY AND REQORK ALL EXISTING UTILITES AS REQUIRED a. co 0 004.21 PULLBOX FOR DATA G PROVIDED B (2) IG52a2 RECEFU PROVIDED BY E.C. 004.21 _ _1 04.20 CONDUIT BY E.C. TO EXIT WA LOCATION TO ALIGN WITH ADJACENT DEOOR WALL PASS thy.\ ] • i INTERIOR ELEVATIONS 1 /2N = V-0" DATA CAME CONOUCTONS 111NO00101D WIIH REtROM KIT Im 'OMWR RECEPTACLES WITNNi aim REFER 70 NEIRM NIT miniocima WORK RE1110Ff KIT. KIT REPLACES DMsiIN• KgSK LIM AND BASE. KIT wmum "Noun W pf CASH HANDLER J8 WITH ONE (1) 1 1 /2- CONDUIT TO 11. ron EXAMPLE IS FOR A SIDE BY SIDE CASH HANDLER THAT DOES NOIT NLALE A 4C FULL NNW MALL. 8000 IT AND LS NEXT TO A KIOSIL 2 EAICH SIDE BY SIDE CASH HANDLER UTILIZES 3 PLUGS AND ADDS 4.4 AILS OF LOAD. f11111111111;� 1'-0" cm iOI , PaMER 12TALL, PRO DE K*= IEM"ACLE AND J-BOK MCI 1" TO AMM CE�xNG�II R DATA CAMM AT LOOAELON Sam NOTM- 1. DWITAL MERCHANDISER CHANNELS ARE DESIGNED 70 REACH UP TO A 10' CEILING. V CUM 0 7AL1JliM. EXIENDER KIT CAN LLE ORDERED TD REACH 12'. FUTURE CASH HANDLER POWER DETAIL 1/4" = 1'-0" POWER DETAIL NOTES 0 - I &Ia --• 1 a I •- 1 Dom m Room M ;V' . I LlM -'. 0► 1 l Lem u' V . 1 6c 0 to]\ .It • --•• I: 1611Aja IV, 1: (lIm © ALL HEADER AND WALL PENETRATIONS FOR CONDUITS OR OTHER ELECTRICAL ROUTING MUST BE SEALED TIGHT. DIGITAL MENU BOARD (DMB) INSTALLATION NOTES: • DMB SUPPORT EQUIPMENT INCLUDES: - NETWORK MANAGEMENT DEVICE (NMD) - 24 PORT ENHANCED WAYPORT SWITCH (EWS) THIS EQUIPMENT IS TYPICALLY MOUNTED IN TECHNOLOGY CLOSET OR IN MANAGER'S OFFICE. • DMB INSTALLERS TO ROUTE CONTROL WIRES FROM NMD/EWS ABOVE CEILING TO MENU BOARD VALANCE WALL. WIRES TO EXIT WALL VIA J-BOXES. • EACH DMB SECTION REQUIRES A DEDICATED MEDIA PLAYER. Q rn 0 U W 1n M N O 3 �1 tr tr U. a a p L v u 4 ��• •ate +� 00 00 L U• 3� • •z� CL Q RECESSED MENU BOARDS 9 THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY ADAM T. = M = RPAL� POWELL, PE USING A DIGITAL SIGNATURE AND DATE. PRINTED COPIES ENGINEERING I N r OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND 9942 CURRIE DAVIS DR. STE H., TAMPA, FL 33619 THE SIGNATURE MUST BE VERIFIED ON TEL (813) 995-0300 ANY ELECTRONIC COPIES. WWW.EMERALDMEP.COM EEI PROJECT# 22072M Lu 0 w ea.. 1802.31 E4*0