Loading...
HomeMy WebLinkAbout39923 Harvest Grove Ctru i\X FTAI -01 am] am] avi FAA, Tki I AB or A.B. Anchor Bolt FIX or FXD Fixed PWDR or Pwd. PowderRoom ABV or Abv. Above FLR or Fir. Floor RA or RIA or R.A. Return Air AC or A/C Air -Conditioner FLR SYS or Fir Sys Floor System RAD or Rad. Radius ADJ or ADJ. Adjustable FOM or F.O.M. Face Of Masonry RAG or Rag. Return Air Grill AFF or A.F.F. Above Finished Floor FP or F.P. Fireplace REC or Rec. Recessed AHU orA.H.U. Air Handler Unit FIR DR French Door RECEPT Receptacle ALT or ALT. Alternate FRT Front REF or Ref. Refrigerator BC Base Cabinet FT or Ft. Foott Feet REINF Reinforcing BF Bifold Door FTG or Fig. Footing REQD or Req'd. Required BK SH or Bk Sh BookShelf FXD GL Fixed Glass RM or Rm, Room BLK or BLK. Block GALV or Galv. Galvanized RND or Rnd. Round BLW or BLW. Below GC or G.C. General Contractor RO or R.O. Rough Opening BM or Bm. Beam GFI or G.F.I. Ground Fault Interrupter RS, R/S, R/SH or R&S Rod and Shelf BOT or Bot. Bottom GT or G.T. Girder Truss SD or SD. Smoke Detector BP or B.P. Bypass(door) GYP BD or Gyp. Bd. Gypsum Board SGD Sliding Glass Door BRG or BRG. Bearing HB Hose Bibb SH or Sh, Shelves C Carpet HDR or Hdr. Header SHT Sheet CAB Cabinet HGT or Hgt. Height SHWR or Shwr. Shower CIR or Cir. Circle HH or H.H. Hand Held (plumbing faucet) SL or S.L. Side Lights CJ or C/J Control Joint HORIZ Horizontal SPECS or SPECS. Specifications CLG or CIg, Ceiling HS Hard Surface (flooring) SPF or S.P.F. Spruce Pine Fir CMU Concrete Masonry Unit ILO In Lieu Of SQ FT or SF or S.F. Square Foot (feet) COFF or Coff. Coffered or Tray Ceiling INSUL or Insul. Insulation SQ or Sq. Square COL or Col. Column INT or Int. Interior STO Storage COMM or Comm. Community KANALL or KIWall Kneewall SW or S.W. Shear Wall COMP or Comp. Compressor KS or K.S. Knee Space SYP or S.Y.P. Southern Yellow Pine CONN or CONN. Connection LAU N or Lau n. Laundry TB Towel Bar CONT or Cont. Continuous LAV or Lay. Lavatory TEMP or Temp. Tempered CT or C.T. Ceramic Tile LF or L.F. Linear Ft. THIKN or Thik'n. Thicken D or D. Dryer LL Lintel Length TOB or T.O.B. Top of Block DB Door Bell LT Laundry Tub TOM or T.O.M. Top of Masonry DBL or Dbl. Double MAS or Mas. Masonry TOP or T.O.P. Top of Plate DCF Decorative Cementitious Finish MAX or Max Maximum TP Toilet Paper Holder DEC or Dec. Decorative MC Medicine Cabinet TR Towel Ring DED or Ded. Dedicated (outlet) MFR or Mfr. Manufacturer TRANS WDW or Trans. Transom Window DIA or Dia. Diameter MGT Management (room) TYP or Typ. Typical DISP or Disp. Disposal MIN or Min Minimum LIC or u.c. Under Counter DIST or Dist. Distance MIR or Mir. Mirror UCL Under Cabinet Lighting DMF Decorative Masonry Finish ML or M.L. Microlam LINO or U.N.O. Unless Noted Otherwise DS or D.S. Drawer Stack MONO or Mono Monolithic V or v. Valve (shower or tub/shower) DTL Detail MW or MICRO or Micro. Microwave VB Vanity Base DV or D.V. DryerVent NTS or N.T.S. Not to Scale VERT or Vert. Vertical DVP or D.V.P. Diverter Valve (plumbing) OE or O.E. Owner's Entry VL or V.L. Versalam DW or D.W. Dishwasher OPNG or Opn'g. Opening VTR or VTE Vent through Roof / Exterior EA or Ea. Each OPT or Opt. Optional Worw Washer ELEC or Elec. Electrical PC Pull Chain W/ or w/ With ELEV or Elev. Elevation PED or Ped. Pedestal WA or W.A. Wedge Anchor EQ Equal PH Phone WC or WIC or W.C. Water Closet (toilet) EW or E.W. Each Way PKT or Pkt. Pocket (Door) WD or Wd Wood EXP or Exp. Expansion Pl. or P.L. Parallam VVDVV HDR or WDVV. HDR. Window Header EXT or Ext. Exterior PLF Pounds per linear foot WH or W.H. Water Heater FBC Florida Building Code PLNT SHLF or Pit. Sh. Plant Shelf WC or W. I.C. Walk-in Closet FDN or Fdn. Foundation PLT HT or Pit. Ht. Plate Height WM or W.M. Wall Mounted (plumbing fixture) FG Fiberglass (Shower Pan) PSF Pounds per square foot WP Water Proof(ing) FIN Finished PT or P.T. Pressure Treated WS Water Softener FIN FLR or FF or Fin. Fir, Finished Floor PW or P.W. Pre -wire WWF Welded Wre Fabric (Mesh) PLAN REVISIONS DATE VERSION DESCRIPTION 08-20-15 1.0 NEW BASE PLAN 12-8-15 2.0 FRAME -WALK REVISIONS 12-27-17 3.0 2017 FBC UPDATES 05-20-19 3. 1 ELEV. Al - REVISED BANDS BACK TO ORIGINAL DESIGN I 08-27-19 3.2 ENG. REVIEW FOR 150-C MPH 09-20-19 3.3 ADD 8'-8" ELEV. FOR TREVESTA 05-14-20 3.4 ELEV. B REV. ENTRY PER M.K. 12-15-20 3.5 OVERHANG OVER SGD REV. TO 3' PER C.M. 12-19-20 4.0 FBC 2020 CODE UPDATE 1551 INDEX OF DRAWINGS I SHEET DESCRIPTION I SHEET No. CS COVER SHEET 1 FLOOR PLAN 2 INTERIOR ELEVATIONS 3.1 EXTERIOR ELEVATIONS 3.2 EXTERIOR ELEVATIONS F1 FOAM DETAILS 4 ELECTRICAL PLAN 5 ROOF PLAN 6 FOUNDATION PLAN MONO 7 ROOF FRAMING PLAN 8 LINTEL PLAN AND DETAILS SN STRUCTURAL NOTES SN1 DETAILS S3M MONO DETAILS S4 DETAILS S5 DETAILS SS RETROFIT DETAILS D1 SECTIONS & DETAILS WP WATERPROOFING DETAILS PA1.0 PRODUCT APPROVAL NUMBERS PA1.1 PRODUCT APPROVAL NUMBERS PA1.2 PRODUCT APPROVAL NUMBERS MEAN ROOF 15 FT. HIGH TYPICAL FOR SINGLE STORY HOMES MEAN ROOF 30 FT. HIGH TYPICAL FOR 2 STORY HOMES I THIS DRAWING AND DESIGN IS VALID FOR 12 MONTHS AFTER THE DATE IT IS SIGNED AND SEALED OR WHILE CURRENT CODE IS VALID CODE REFERENCES ARE SUMMARIES OF CODE SECTIONS. SEE FBCR (CURRENT VERSION) FOR COMPLETE CODE INFORMATION. Notice to Builder & All Subcontractors It is the intent of Designer/Engineer listed in the titleblock of these documents that these documents be accurate, providing Licensed Professionals clear information. Every attempt has been made to prevent error. The Builder and all subcontractors are required to review all the information contained in these documents, prior to the commencement of any work. The Designer/Engineer are not responsible for any plan errors, omissions,or misinterpretations undetected and not reported to the Designer / Engineer prior to construction. All construction MUST be in accordance to the information found in these documents. Any questions regarding the information found in these plans should be directed to our Office at (407) 880-2333 immediately. No backcharges will be considered for reimbursement by the Designer/Engineer without advanced notification and approval by the Designer/Engineer. Payments will be made in accordance to the terms of the agreement. Control of Construction Site: The Designer/Architect and engineer of record (EOR) have no control over the construction site and shall not be responsible in any manner for control of the construction site including, but not limited to, scheduling and sequencing of work, jobsite safety, and ventilation of the building and thereby shall not be responsible for the indoor air quality, or the effects thereof, for any reason whatsoever. The Designer/Architect and EOR has no duty to protect, without limitation, the residence, construction site, materials, or equipment, from moisture, mold, fungus, fire, theft, vandalism, trespass, or any other peril or condition, at any time, expressly including, but not limited to, the period of time before construction, during the construction of the project, or after construction and the Designer/Architect and EOR has no duty to take any action or preventive measures to protect such property against any such peril at any time for any reason. L E V .......... 01 NO P" 7 5 0 To the best of the Engineers knowledge, information and belief, the structural plans and specifications contained within these drawings comply with the 2020 Florida Building Code - Residential 7th Edition. Engineers signature and seal is only for the structural engineering portions of the drawing pages bearing Engineers signature and seal. W E 08. c, c-, CD C LL 0 '.o M LL LL Z _J 0 M 0 �- = 0 W W 0 U) co � M < < Z 00 L0 Z a- U) 0 C14 0< <:) 0 U) Z W �2 < V) 0 4-1 U Ul) E 2 8 0 <3C C:, CC) Cl) Z < LL. E 0 Z @ C" 2� -0 CL C14 1Z '0 1, C/3 CZ . O� Z , Z .2 �Z < 1Z 0 E NJ Z < '0 0 .2 C:) 0 00 0 0 it > (1) N > 0 C) 0 (0 Co C r*1 0 E L_ C%4 Col CD Lo 2: CN LO co 0-) LO M 00 C14 M C14 1- E 0 ;Eca Z E cc E 0 0 0 _J 'a < _J JOB NO: 21-2029 SCALE : AS NOTED SHEET NO. C S 1. N -1 ommon U? LO (D 7- CN f A 1��) TYP @ 1 STORY QU5 do (0 C> Ln PATIO 4'-0" Q? G) LO Cl) H �� TYP @ 1 STORY 1 8 115'-8'2" OWNER'S F_ SUITE 8'-0" CLG. CARPET (3) 2x4 #2 SPF 00 w/ DTT2Z (0 00 C14 6-35." r lin"I I Al-n-11 1 9 4) di 8 CAFE1 VAULT. CLG! CARPET 2-12 SLOPE MILING (D 04 Cl) /L - - - - - - - - FAMILY RM 16-881" VAULT CLG. CARPET 00 j eli .0 I�V. k:j .1, FIBERGLASS SURROUND T-0" 0 BATH 60"x36" --_Oil. 8'-0'! CLd. 2068 B.F. TILE--T LINEN C 5-SH 00 16" DEEP (0 00 C14 8'-2" W. LC AHU 8'-0" CLG. CARPET ------------- R&S F_ D.W. El U), Z�k < 10 I'V-41 KIT. - .... k6' 1 CLI�,L2,, 1 216" ITIL 06K- - 7 PANTRY N_ 8*-0" CLG. Midi OPT, d �)0 Loz -PEE. z �R 5-SH 16- DEEP/ 36"A.F.F. r_z-r=z=-=t IT" 8" L _OPT� W 1AU-N. 8'-0" CLG.-- : 72a868 �T4LE JA S3 TYP @ 1 STORY 0 25-SH C, 1 4 (FIBERGLASS 11-URROUND 10-4- 8 09 T�- T 12' C;1 LO T LGI '9 o LO CN TIL qo BEDROOM 2 BEDROOM 3 r 8'-0" CLG. 9 8'-0" CLG. o? CARPET U') 8-4- CARPET 2'4' T-721. 4 2r) 8'-838" /"'A 2668 d 2668 80 -1 4068 B.F. 4068 B.F. TYP @ 1 STORY Z:L - - - - - - - - - - - - VJ ("I R&S z 166 Lu R&S-R - - - - r- - - - - - - - - - - - - - - - R&S 2068 B.F. H AT T-4" (3) 2x4 #2 SPF FO ER T TILE W/ DTT2Z it [o 6-1041" 1, 9'-113"�LG. 01, PA 3068 C� zo BUILDER TO PROVIDE W APPLIANCE Dwo-.,. CN PROTECTION WHEN .H REQUIRED PER FBC 2'-6" A- ip C-, JAU) I LO ILLI X 1. Q - I 00 9 _G)_ If 20'- L - - EDGE OF SLAB 2" BEYOND WALL 7�._T C F - - - S3 DRYER VENT THRU WALL CAR GARAGE LPI 8'-0" CLG. 20'-7k 54'-0" 5 �NTRY 8'-0" CLG. IS W uJ 0 0 r- 0 CD I TYP @ GARAGE OPENING K ------------- H.B. 24"x24" CMU BASE COLUMN w/ (4) #5 VERTICALS GROUT SOLID EE ELEV. FOR H(SEIGHT) 4x4 P.T. #2 SYP POST TO SIT DIRECTLY IN CENTER W/ SIMPSON ABU44 (2 TYP.) CD 5 C14 9 60 9 N HEADER SCHEDULE MARK HEADER SIZE REMARKS (2) - 2X6 #2 SYP W/ 1/2" FLITCH PLATE (2) - 2X8 #2 SYP W/ 112" FLITCH PLATE (2) - 2X1 0 #2 SYP W/ 1/2" FLITCH PLATE (2) - 2X 12 #2 SYP W/ 1/2" FLITCH PLATE (2) - 1 3/4" X 11 1/4 LVIL 2.OE Fb=2950 (2) - 1 314" X 9 1/4" LVL 2.OE Fb=2950 (2) - 1 3/4" X 16" LVL 2.OE Fb=2950 (2) - 1 3/4" X 7 1/4" LVL 2.OE Fb=2950 (2) - 2X4 #2 SYP W/ 1/2" Follow QJS4. See Plan for RAG FLITCH PLATE Bearing Wall Call Out When Straps are Required VERIFY W/ PLAN CORRECT LENGTH OF HEADER REQUIRED SEE PLAN FOR DETAIL CALL OUT FOR CONNECTIONS AND REQUIRED STUDS WINDOW SCHEDULE SIZE R.O. CMU (Flange) R.O. FRAME (Fin) TYPE 12 20 X 26 184X254 S.H. 13 20 X 381 18JX374 S.H. 14 20 X 501 18 JX 50 S.H. 15 20 X 63 18 JX 624 S.H. 16 20 X 72 184 X 714 S.H. 111-12 27 1/4 X 26 26 X 25 4 S.H. 11-13 27 1/4 X 38 J 26 x 374 S.H. 11-14 27JX 501 26 x 50 S.H. 11-15 27 J X 63 26 X 62 1/2 S.H. 11­16 27 J X 72 26 X 71 1/2 S.H. 22 37 J X 26 36JX25 1/2 S.H. 23 37 J X 38 J 36 J X 37 3/4 S.H. 24 37 J X 501 36 J X 50 S.H. 25 37JX63 36JX62 1/2 S.H. 26 37 J X 72 36 J X 71 1/2 S.H. DOUBLE 2 WIDE 75" TALL 73JWIDE S.H. 32 54 X 26 52 J X 25 4 S.H. 33 54 X 381 52JX 374 S.H. 34 54 X 501 52 J X 50 S.H. 35 54 X 63 52 4X 62 4 S.H. 36 54 X 72 52 4 X 711 S.H. 39X59 40 X 59 N/A S.H. DOUBLE 39X59 79X59 N/A S.H. General Notes R302.5 Dwelling/Garage Open ing/Penetration Protection Opening and penetrations through walls or ceilings separating the dwelling from the garage shall be in accordance with sections R302.5.1 through R302.5.3. R302.5.1 Opening Protection Openings from a private garage directly into a room used for sleeping purposes shall not be permitted. Other openings between the garage and residence shall be equipped with solid wood doors not less than 1-3/8" in thickness, solid or honeycomb -core steel doors not less than 1-3/8" thick, or 20-minute fire -rated doors. R302.5.2 Duct Penetration Ducts in the garage and ducts penetrating the walls or ceilings separating the dwelling from the garage shall be constructed of a minimum No. 26 gage (0.48 mm) sheet steel, 1 inch minimum rigid nonmetallic class 0 or classl duct board, or other approved material and shall not have openings into the garage. R302.5.3 Other Penetrations Penetrations through the separation required in Section R302.6 shall be protected as required by section R302.1 1, Item 4. R302.6 Dwelling/Garage Fire Separation The garage shall be separated as required by Table R302.6. Openings in garage walls shall comply with Section R302.5. Attachment of gypsum board shall comply with Table R702.3.5. The wall separation provisions of Table R302.6 shall not apply to garage walls that are perpendicular to the adjacent dwelling unit wall. R312.2.1 Window Sills In dwelling units, where the top of the sill of an operable window is located less than 24 inches (610 mm) above the finished floor and greater than 72 inches (1829 mm) above the finished grade or other surface below on the exterior of the building, the operable window shall comply with one of the following: 1. Operable windows with openings that will not allow a 4-inch-diameter (102 mm) sphere to pass through the opening where the opening is in its largest opened position. 2. Operable windows that are provided with window fall prevention devices that comply with ASTM F2090. 3. Operable windows that are provided with window opening control devices that comply with Section R312.2.2. Chapter 45 Private Swimming Pools Outdoor swimming pools shall be provided with a barrier complying with R4501.17. 1.1 through R4501.17.1.14. M1507.2 Re -circulation of Air Exhaust air form Bathrooms and toilet rooms shall not be re -circulated within a residence or to another dwelling unit and shall be exhausted directly to the outdoors. Exhaust air from bathrooms and toilet rooms shall not discharge into an attic, crawl space or other areas inside the building. GAS APPLIANCES G C to verify location of gas riser before commencement of work. Where gas water heaters are installed. Water heaters shall be installed a min. of 18" above fir. per FBCR G2408.2. Except where appl'iances that are listed as flammable vapor ignition resistant. OPENING PRESSURES ENCLOSED - EXPOSURE "C" +29.7 -32.2 +29.7 / -39.7 +28.3 -30.8 +28.3 / -37.0 ®r- +26.6 -29.1 +26.6 / -33.5 S EE S N SHEET SEE SN SHEET i NOTE: WIND SPEED INDICATED ABOVE IS AN "ULTIMATE" WIND SPEED. THE WIND PRESSURES LISTED ABOVE ARE ALLOWABLE PRESSURES SOFFIT DESIGN PRESSURE 1 +29.7 / -39.7 WALLLEGEND I I I 7MMASONRY HGT. @ 8'-0" A.F.F. TYP. 2x FRAME WALL BEARING WALL INTERIOR BEARING WALLS NOTED "FLOOR BEARING ONLY" ARE FLOOR SYSTEM SUPPORTING ONLY AND REQUIRES NO UPLIFT CONNECTORS TO FLOOR SYSTEM AREA TABULATION '1131 11 (TRB)_ 1ST FLOOR LIVING AREA 1555 LIVING TOTAL 1555 GARAGE 408 FRONT ENTRY 42 TOTAL AREA 2005 FLOOR PLAN - ELEV-B1 INSULATION REQ. LOCATION R-VALUE / TYPE EXT CONIC WALL R-4.1 HIGH PERM EXT FRAME 2 x 4 R-1 1 /R-1 3 KRAFT FACED EXT FRAME 2 x 6 R-19 KRAFT FACED CONDITIONED CEILING R-30 BLOWN -IN (INSTALL BAFFELS AT EAVE) SCALE: )/4"=V-131" GARAGE SEPARATION (GARAGE / LIVING) R-11/R-13 KRAFT FACED C14 C14 S AA C, '0� tx'. . To the best of the Engineer's knowledge, information and belief, the structural plans and specifications contained within these drawings comply with the 2020 Florida Building Code - Residential 7th Edition. Engineers signature and seal is only for the structural engineering portions of the drawing pages bearing Engineers signature and seal. W V E 00 0 C, 8 C� 04 (A 0 c: W, "n *t LU r- [-� I? L-, Lu a - No (L-- 4 C6: m LL LL z 0 0 - 19 = C0 0 F .- Lr y _J M 04 1U W P_ M 0 M M (0 < Z LL 00 C5 (L L5 C'J z R L0 0 Cl) 3 N < < 0 z W iz- :�c 0 V) 0 01 (L) 4-J U 0 ]k g 5 U) C) 6 E C0 < 0 C:, M C13 z 0 z __J LJ_ cd E ca- 0 E R 0 ca CL 0 3R < 00 C=) E " M <z 0 W, z 09 z z W z '0 Z5 0- z W C) Z CD CD 01< 0 0 z 0 .0 C:) _J 0 00 0 0 > Q) CN > 0 0 0 C: C 0 E 04 co CD LO 04 LO Cl) (M LO 00 CNI 04 E E CV) 0 z E 10 CU cc FL E 0 0 - 0 _J -0 1� < a 4) _J JOB NO: 21-2029 SCALE : AS NOTED SHEE7 NO. KITCHEN ISLAND 9 9 Lj 9 ZN 9 OPT. REF. KITCHEN VARIES, 2" LESS THAN CABINETS BELOW MIRROR VARIES W MEDICINE CABINET 00 02 0 z LL LL C) > (N > -1 - -1 = co N co 14t co M LJ HOOD 9 9 RANGE X 24" TOWEL BAR ON WALL ABOVE TOILET TOILET PAPER HOLDER C14 FIN. FLR. KITCHEN MIRROR _T 44­1 9 80 9 9 BATH 2 NOTE: THIS DIAGRAM DEPICTS TYPICAL INSTALLATION GUIDELINES TO BE FOLLOWED U.N.O. ON PLANS SHWR. SHWR. DOUBLE CURTAIN HEAD RODS ROD 0- TOWEL BAR IN TUB OR SHWR. n Uj TOWEL BAR ON BATHROOM WALL 3: SHWR. VALVES LU 00 9 I SOAP EO d r- - to 60 C DISH _j -1 C1 LO -1 U') C) C) 0 -1 CY) co 0 TUB BATHROOMS. SHOWERS AND TUBS 9 9 MIRROR ILL171 11il 110-1 LILl M__j OWNER'S BATHROOM 54-N, INTERIOR ELEVATIONS SCALE: 1/2"=l'-O" 42" H UPPER CABINETS 36" H UPPER CABINETS - 16" FOR LINEN 30" H UPPER 12" FOR PANTRY CABINETS ---------- OVERHANGS THAT SINGLE EXCEED12"MAY ROD REQUIRE A SUPPORT BRACKET 36" H BASE 0 FINISHED CABINETS - 0 a COUNTER TOP ln" W F1AQP CLOSETS / LAUNDRY C) - I 00 ILL 7 LO 0- 0 2x L? 0? FRAMING 1/2" GYP BOARD — FIN. FLR. 2x P.T. SHELVING CABINETS - C) (y) CN ISLAND COUNTER III C) 04 04 FIN. FLR.j' �L�jjj CABINET BLOCKING �K my BLOCKING AND MOUNTING DETAILS SCALE: 1/2"=l'-O" 1 zz� "�J%11111111111 C14 CD %0% �_p W K 'I 0 . ........ NSC CZZ LLJ To the best of the Engineers knowledge, information and belief, the structural plans and spedfications contained within these drawings comply with the 2020 Florida Building Code - Residential 7th Edition. Engineers signature and seal is only for the structural engineering portions of the drawing pages bearing Engineers signature and seal. u) Po co, C� 0, LL CC31 ICU: 0 co 'X Z8 _j *k `� L� -C' LL uj LL uj 0 0 C 0 0 0 W 05 1.31: co 9 z 00 0 1r) co z _j x L/) 0 < d U z W F U CD 20 2� i:z- 0 CS V) LLJ E 8 X0 0 CD z E z 0 E U C" z F_ CL E 5C 0 z C'j ru t 0 < 0. Z 0 < 8 CL 2. 0 < C:) CD to M 00 0 0 Nt (1) CN > 2 0 — (D C 0 r�_ E &_ C\1 co CD Lo x 04 LO Cf) 0.) Lf) 00 C%j 0) C3) E el CY) 0 ca z :3 E 42) M E 0 0 < L JOB NO: 21-2029 SCALE AS NOTED SHEEr NO. 2 III I I 1 1 1 1 1 1 1 1 1 1 1 1 11MI-1 1711 A I 1 111111 PRE -ENGINEER TRUSS 12 5 12 F5 12 5 �5 3 TAB SHINGLES. ROOF INSTALLED AS PER MANUF. SPECIFICATIONS 12 - - - - - - - - - - - - - - HEEL - - - - - - - - - - - - - - - - - T.O.M. - - - - - - - 7 - - - - - - HDR HGT 1 x 9" SMOOTH TEXTURED =7 1 2' EJ E FE11 7E] HEAD/BAND-Z 1 1 —TEXTURED CEMENTITIOUS FINISH ON C.M.U. (TYP.) ji FE71 2" x 4" SMOOTH TEXTURED SILL / BAND ------------- _74 11 L 1_1 ------------------------ F.FL. 12 5[�:� 11-01, 4'RIDGE VENT FRONT ELEVATION - B1 SCALE: 11/4"=V-0" 18'RIDGE VENT C? co 11-01, U) iLi 0) uJ U) W (D co LU I Fl". FLR.. 3 TAB SHINGLES. ROOF INSTALLED AS PER MANUF. SPECIFICATIONS T.O.M IlkT-O" TEXTURED TEXTURED CEMENTITIOUS 9 CEMENTITIOUS 0? FIN. ON C.M.U. BO FINISH ON C.M.U. (TYP.) (TYP.) 2" x 4" SMOOTH TEXTURED SILL / BAND t F.FL. LEFT ELEVATION - B1. SCALE: 1/4"=V-0" —REFER TO FRAMING PLAN FOR BEAM SIZE ---- 2"X4" TYP. 5/8" TEXTURED OVER MTL. LATH & 7/16" OSB SHEATHING & FRAMING AS REQ. REFER TO FLOOR PLAN FOR POST SIZE 2 2 —2x FRAMING AS REQ. POST TO CMU CONNECTOR - REFER TO FLOOR PLAN (1) 2"X4" TYP (2) 2"X6" TYP — — — — — — — — — — —SEE FOUNDATION PLANS FOR FOOTER SIZE General Notes ROOF CRITERIA: 12" OVERHANG U.N.O. PLUMB CUT FASCIA ROOF PITCH PER ELEVATION **G.C. VERIFY ROOF PITCH" ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE CONTRACTORS RESPONSIBILITY TO VERIFY ROOF SLOPE REQUIREMENTS WITH TRUSS MANUFACTURER. "ELECTRICAL SPECIFICATION NOTES" ELECTRICAL CONTRACTOR MUST VERIFY WITH THE SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT FIXTURES SHOWN ARE FOR LOCATION PURPOSES. Exterior Covering R703.7 Exterior Plaster. Installation of these materials shall be in compliance with ASTM C926 and ASTM C1063, or ASTM C1787 and the provisions of this code. R703.7.1 Lath. Lath and Lath attachments shall be of corrosion -resistant materials. Expanded metal or woven wire lath shall be attached with 1-1/2" long, 11 gage nails having a 7/16" head, or 1-1/2" long, 16 gage staples, spaced in accordance with ASTM C1 063 or C1 787, or as otherwise approved. R703.7.2 Plaster. Plastering with cement plaster shall be not less than three coats where applied over any type of code -approved lath and shall be not less than two coats where directly applied over masonry, concrete, clay brick, stone, or tile. If the plaster surface is completely covered by veneer or other facing material or is completely concealed, plaster application need be only two coats, provided total thickness is as set in Table R702.1 (1). Cement plaster shall be in accordance with ASTM C926 and material shall be in accordance with one of the types listed in R703.7.2. R703.7.3 Water -Resistive Barriers. Water -resistive barriers shall be installed as required in Section R703.2 and, where applied over wood -based sheathing, shall include a water -resistive vapor -permeable barrier with a performance at least equivalent to two layers of Grade D paper. The individual layers shall be installed independently such that each layer provides a separate continuous plane and any flashing (installed in accordance with Section R703.4) intended to drain to the water -resistive barrier is directed between the layers. R703.2 Water -Resistive Barrier. One layer of No. 15 asphalt felt, free from holes and breaks, complying with ASTM D226 for Type 1 felt or other approved water -resistive barrier shall be applied over studs or sheathing of all exterior walls. No. 15 asphalt felt shall be applied horizontally, with the upper layer lapped over the lower layer not less than 2 inches. Where joints occur, felt shall be lapped not less than 6 inches. Other approved materials shall be installed in accordance with the water -resistive barrier manufacturer's installation instructions. The No. 15 asphalt felt or other approved water -resistive barrier material shall be continuous to the top of walls and terminated at penetrations and building appendages in a manner to meet the requirements of the exterior wall envelope as described in Section R703.1. R703.4 Flashing. Approved metal flashing, vinyl flashing, self -adhered membranes and mechanically attached flexible flashing shall be applied shingle -fashion or in accordance with the manufacturer's instructions. Metal flashing shall be corrosion resistant. Fluid -applied membranes used as flashing shall be applied in accordance with the manufacturer's instructions. All flashing shall be applied in a manner to prevent the entry of water into the wall cavity or penetration of water to the building structural framing components. Self -adhered membranes used as flashing shall comply with AAMA 711. All exterior fenestration products shall be sealed at the juncture with the building wall with a sealant complying with AAMA 800 or ASTM C920 Class 25 Grade NS or greater for proper joint expansion and contraction, ASTM C1 281, AAMA 812, or other approved standard as appropriate for the type of sealant. Fluid -applied membranes used as flashing in exterior walls shall comply with AAMA 714. The flashing shall extend to the surface of the exterior wall finish. Approved flashings shall be installed at the following locations. Exterior window/door openings. Intersection of chimneys or other masonry construction with frame walls. Under and at the ends of masonry, wood or metal copings and sills. Continuously above all projecting wood trim. Where exterior porches, decks or stairs attach to a wall or floor assembly of wood -frame construction. At wall and roof intersection. At Built-in gutters. Coastal Flashings All flashing material for coastal locations (ex: within 3,000 feet of the ocean) shall be corrosion resistant material (ex: zinc and/or stainless steel) and shall be selected for compatibility with adjacent wood preservatives per the manufacturer's recommendations. C14 C� 2! A,\ 0 cc W 1F LJ - To the best of the Engineers knowledge, information and belief, the structural plans and specifications contained within these drawings comply with the 2020 Florida Building Code - Residential 7th Edition. Engineers signature and seal is only for the structural engineering portions of the drawing pages bearing Engineers signature and seal, W 'IT 00 c, E 8 (0 cc, U� 0 .0 ID LU U) t­ E I? Lu N 0 u_ (L 6 M u_ U_ CL Lu 3: _J - - - 0 Z :�. -. ;, 0 'IT M C, 0 'CU 04 CD LL —J W W Do 0 oo J < U) c� < Z LL 0 9L L0 Cl) Z L/) 0 a C14 < < D 0 b L) -i (f) Z W _5 0 v) B- (U V) C) Z�_ E 0 C) 2 C�� 6� 4) 0 < 2 0 0 cl� 0 Z Z < E 0 Z Z < E C1 CZ) 0 < 0 �z 0 0 < Z �z Z cli M < C: �z 0 ow Z' Z Z C', < -W Z Z 0 Z W U C=) 0 X 8. .2 0 0 00 > NT CL) N > 2 (D 0 C.0 0 E 04 LO M: 04 LO M 0) U-) ]LI 00 04 1 CD E CY) 0 CU Z E Cn co E 0 0 'a < JOB NO: 21-2029 SCALE : AS NOTED SHEEr NO. 3.1 I I -17'OFFRIDGE VENT 4'OFFRIDGE VE 12 12 5 3 TAB SHINGLES. ROOF INSTALLED AS PER MANUF. SPECIFICATIONS — - - - - - - - - - - - -------------- EXTENDED OVERHANG TO BE CENTERED ON DOOR--/ TEXTURED CEMENTITIOUS FINISH ON C.M.U. (TYP.) REAR ELEVATION - B1 4'RIDGE VENT 12 77' 5 3 TAB SHINGLES. ROOF 5 INSTALLED AS PER MANUF. 18'RIDGE VENT SPECIFICATIONS T.O.M. SCALE: 1/4"=1'-0" T.O.M. HDR L F.FL. 9 bD co (D HDRHGT -- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - V-01, TEXTURED CEMENTITIOUS TEXTURED FINISH ON C.M.U. CEMENTITIOUS C? (TYP.) FINISH ON C.M.0 Zo (TYP.) J F.FL . . . . . . . . . . . . A A RIGHT ELEVATION - B1 SCALE: 1/4"=V-0" General Notes ROOF CRITERIA: 0 12" OVERHANG U.N.O. 0 PLUMB CUT FASCIA ROOF 0 PITCH PER ELEVATION **G.C. VERIFY ROOF PITCH" ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE CONTRACTORS RESPONSIBILITY TO VERIFY ROOF SLOPE REQUIREMENTS WITH TRUSS MANUFACTURER. "ELECTRICAL SPECIFICATION NOTES" ELECTRICAL CONTRACTOR MUST VERIFY WITH THE SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT FIXTURES SHOWN ARE FOR LOCATION PURPOSES. Exterior Covering R703.7 Exterior Plaster. Installation of these materials shall be in compliance with ASTM C926 and ASTM C1063, or ASTM C1787 and the provisions of this code. R703.7.1 Lath. Lath and Lath attachments shall be of corrosion -resistant materials. Expanded metal or woven wire lath shall be attached with 1-1/2" long, 11 gage nails having a 7/16" head, or 1-1/2" long, 16 gage staples, spaced in accordance with ASTM C1063 or C1787, or as otherwise approved. R703.7.2 Plaster. Plastering with cement plaster shall be not less than three coats where applied over any type of code -approved lath and shall be not less than two coats where directly applied over masonry, concrete, clay brick, stone, or tile. If the plaster surface is completely covered by veneer or other facing material or is completely concealed, plaster application need be only two coats, provided total thickness is as set in Table R702. 1 (1). Cement plaster shall be in accordance with ASTM C926 and material shall be in accordance with one of the types listed in R703.7.2. R703.7.3 Water -Resistive Barriers. Water -resistive barriers shall be installed as required in Section R703.2 and, where applied over wood -based sheathing, shall include a water -resistive vapor -permeable barrier with a performance at least equivalent to two layers of Grade D paper. The individual layers shall be installed independently such that each layer provides a separate continuous plane and any flashing (installed in accordance with Section R703.4) intended to drain to the water -resistive barrier is directed between the layers. R703.2 Water -Resistive Barrier. One layer of No. 15 asphalt felt, free from holes and breaks, complying with ASTM D226 for Type 1 felt or other approved water -resistive barrier shall be applied over studs or sheathing of all exterior walls. No. 15 asphalt felt shall be applied horizontally, with the upper layer lapped over the lower layer not less than 2 inches. Where joints occur, felt shall be lapped not less than 6 inches. Other approved materials shall be installed in accordance with the water -resistive barrier manufacturer's installation instructions. The No. 15 asphalt felt or other approved water -resistive barrier material shall be continuous to the top of walls and terminated at penetrations and building appendages in a manner to meet the requirements of the exterior wall envelope as described in Section R703. 1. R703.4 Flashing. Approved metal flashing, vinyl flashing, self -adhered membranes and mechanically attached flexible flashing shall be applied shingle -fashion or in accordance with the manufacturer's instructions. Metal flashing shall be corrosion resistant. Fluid -applied membranes used as flashing shall be applied in accordance with the manufacturers instructions. All flashing shall be applied in a manner to prevent the entry of water into the wall cavity or penetration of water to the building structural framing components. Self -adhered membranes used as flashing shall comply with AAMA 711. All exterior fenestration products shall be sealed at the juncture with the building wall with a sealant complying with AAMA 800 or ASTIVI C920 Class 25 Grade NS or greater for proper joint expansion and contraction, ASTM C1281, AAMA 812, or other approved standard as appropriate for the type of sealant. Fluid -applied membranes used as flashing in exterior walls shall comply with AAMA 714. The flashing shall extend to the surface of the exterior wall finish. Approved flashings shall be installed at the following locations. • Exterior window/door openings. • Intersection of chimneys or other masonry construction with frame walls. • Under and at the ends of masonry, wood or metal copings and sills. • Continuously above all projecting wood trim. • Where exterior porches, decks or stairs attach to a wall or floor assembly of wood -frame construction. • At wall and roof intersection. • At Built-in gutters. Coastal Flashings All flashing material for coastal locations (ex: within 3,000 feet of the ocean) shall be corrosion resistant material (ex: zinc and/or stainless steel) and shall be selected for compatibility with adjacent wood preservatives per the manufacturer's recommendations. 2! x.EWK(:), N S,�'* A - ��+Z 1510 00, A 41Z % To the best of the Engineers knowledge, information and belief, the structural plans and specifications contained within these drawings comply with the 2020 Florida Building Code - Residential 7th Edition. Engineers signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. ij W E 8 C0 C, 04 0) 0 02 00 it W t-� �? 04 0 - a. u_ CL LL U_ LU Z r) 00: _r_ Co — -F, CZJ 0 M .J W W :3 0 U) M M LL Lo Cl) Z X D 0 0 C14 < 00 L) _j Z W [,7 1' 7 1 (D mn !�2 W V) .2 u- 4-J �F LLJ a. 0 M V) U) E 0 C_ U) 0 N F- CC) CMO co Z Z < LL_ C6 CL 0 E � 0 Z < Z a y 0 CL 0 '0 0 Z CD E CN t � 0 < Z 0 H--Z no C: < '0 0 Z Z Z 0 0� ZZ U W -Z C> 6 E 0� .0 C:) _J cc 00 0 > > 2 (0 C C 0 E L_ 04 co 0 Lo M: CN U U-) 00 CN E 0 W Z :3 E 2 cc C ca E 0 0 'a cc < 0 1 (D _J JOB NO: 21-2029 SCALE : AS NOTED SHEET NO. 3.2 V-1011 ill CAP CAP VARIES 2 1 6 2" *NOTE: 1" RADIUS Cl) —Ilk N FOAM TO BE USED I &D ONLY WHEN 1/2" RADIUS K REQUIRED BY 3 1/2" RADIUS - - J. COMMUNITY 3/4" RADIU 00 SPECS. IF NOT, L CD OPENINGVARIES 2- 2 DETAIL TO BE F- M r BUILT W/ STUCCO. 1/2" RADIUS — 111- 4" VARIES 1/2 :'RJ EDGE OF i OPENING VARIES VARIES 22 2 VARIES 4" 411, 2" 1 1/2" RADIUS — 4" 2 2 1/2" RADIUS 311, 4 (D MAI CD VARIES 321" 321" j" 11. BASE BASE 3" 2 4 4 4 4" fill '0:WK0 J"f U. ...... 2 N S *NOTE: VARIES 8" 2 FOAM TO BE USED 2 cc: ONLYWHEN UJZ 3- REQUIRED B Ui Y 01F COMMUNITY 4" 211) 3" 4 34) SPECS. IF NOT, OPENING VARIES 4. DETAIL TO BE BUILT W/ STUCCO. 2� EDGE OF OPENING 01 1 1-1/2" THICK 1-1/2" THICK To the best of the Engineer's knowledge, information and belief, E5 the structural plans and specifications contained within these M 101, drawings comply with the 2020 Florida Building Code - 4" Residential 7th Edition. Engineers signature and seal is only for z the structural engineering portions of the drawing pages bearing !;2 101, 6-1 Engineers signature and seal. 21 C14 c3 4 co E c:) c) Cc, U 0 2 LU T" 0 U5) , �. uj a- N 0 u_ a. 21 se ai ca L.L LL C14 (D 0 — Cl) WO —03 .24— '0 .5 .5 cN Co 4 6" W 0 0, C"4 Lij W C) !-.9 C2 < < 2- L4— 3- co 2 LL Wz LO 04 Z X Ln 0 0: 0 -.j C14 C14 c o < C) 00 z W M 1-1/2" THICK 31- 93 2 21" 4 iz� 2'-4" < 4" m- 51' 7" 2 V) 51" 1'-4" 3" W c�? 4 > NJ o Q) (D C-4 IN 4- ia VARI VARIES c5 C'4 0 Lu C) 4 C14 — Ln U C> Cn E LU < U > o VARIES VARIES < l.r, o -If I 4" 8" CD z 2 M o < co __j 6" 4" KEYSTONE F1 1 0 KEYSTONE Fl 1 r- U- 41" r---------- -- 0) ------- _o C OPTIONAL OPTIONAL ca po C) 00 3" o < C:3 E � c x z C> z -z 4" GARAGE DR c14 wo cL 3" 4" I — o. o E 4 GARAGE DR. OPENING z t 4" 4" WINDOW OPENING 4 42- ra C o =3 E �E 'o CJD z (D I NOTE: 'z E e INSTALL OVER STONE, TYP. (n < -w z cn 8. < cl * FIN. TO HAVE TRADITIONAL o z VARIES LOOK & SMOOTH FINISH o 11 W E FOAM/ EPS MATERIAL IS 'z C:1 ;� ACCEPTED to o. o NOTE: A E2 —0 e FIN. TO HAVE TRADITIONAL LOOK & 2--1 .0 C) SMOOTH FINISH 4, "a 14, 2 1. 5j" V-11' 53' 0 2" * FOAM/ EPS MATERIAL IS ACCEPTED 2 4 6 T-8" 7" 4" T-0" 4" (0 0 101, 1141, 101, t: L— :3 00 0 2" jk — /j a) 0 Nt > 00 0 N - r, zi ZP 0 0 v C ILL 0 E &- 04 CD co LO Z: 04 7 CY) cp U-) CK) CY) 0 E z o? 9 ca z E CL. E 0 0 'D CD C) 'Y70" 2 SCALE AS NOTED "'701 SHEET NO. GENERAL NOTES: CD 1.5 LBS DENSITY STYROFOAM POLYCOAT (HARD COAT) F ACRYLIC SAND FINISH ELECTRICAL SPECIFICATION NOTES: ELECTRICAL CONTRACTOR MUST VERIFY WITH THE SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT FIXTURES SHOWN ARE FOR LOCATION PURPOSES. GENERAL ELECTRICAL NOTES: Notes: unless otherwise noted, 1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). In a Flood Zone, all electrical equipment to be at or above DFE. Kitchen 44" AFF Bathroom 39" AFF Laundry Room 36" AFF Exterior Waterproof 12" AFF Garage - general purpose 44" AFF Range 2" AFF 2. All trim plates and devices to be ganged, where possible. 3. Electrical switches to be at 42" centerline above finished floor. 4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & sizing of all electrical, wiring & accessories. 5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. 6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in LIL 1699. 7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC 2017). 8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or LIL 2075, gas and vapor detector sensor, according to the installation. 9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a Nationally Recognized Testing Laboratory. 10. Keep all smoke detectors minimum of 36" from bathroom doors. 11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be equipped With a monitored battery backup. 12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not acceptable. 13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying with R4501.17.1.1 through R4501.17.1.14. 14. Add GFC1 protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in corner counters. ELECTRICAL KEY DUPLEX CONVENIENCE OUTLET FfF DUPLEX OUTLET ABOVE COUNTER I F3--W.P. WEATHERPROOF DUPLEX OUTLET K)G.F.I. GROUND FAULT INTERRUPTER DUPLEX OUTLET HALF -SWITCHED DUPLEX OUTLET F`,z-V SPECIAL PURPOSE OUTLET DUPLEX OUTLET IN FLOOR 220 VOLT OUTLET $ WALL SWITCH $3 THREE-WAY SWITCH �4 FOUR-WAY SWITCH $R RHEOSTAT SWITCH CEILING MOUNTED LIGHT FIXTURE HI -HAT - TO BE SURFACE MOUNTED ON J-BOX WALL MOUNTED LIGHT FIXTURE @) RECESSED LIGHT FIXTURE LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS TRACK LIGHT FLUORESCENT LIGHT FIXTURE 16) EXHAUSTFAN EXHAUST FAN/LIGHT COMBINATION ELECTRIC DOOR OPERATOR (OPTIONAL) KH] CHIMES (OPTIONAL) �D PUSH BUTTON SWITCH (OPTIONAL) HE9 PUSH BUTTON SWITCH - DOOR BELL @ SMOKE DETECTOR SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) TELEPHONE (OPTIONAL) USB TELEPHONIE/USB (OPTIONAL) TELEVISION (OPTIONAL) 2 (2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. THERMOSTAT ELECTRIC METER awl ELECTRIC PANEL DISCONNECT SWITCH ROUGH -IN FOR OPT. CEILING FAN CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR OPT. CEILING FAN (1) PHONE LINE, (1) DATA PORT 150AI200A INDOOR NEMA 1 150 AMPI 200 AMP METER n 200 amp 150 amp 14 copper to lights & outlets 12 copper to 20 amp ckts 10-2 copper to WH 10-3 copper to Dryer or 4/0 SER Alu isco t UNDERGROUND _jtnne ct POWER CO. FEED INTERSYSTEM 4 Bare Cu Ground C BONDING #4 GROUNDING WIRE TERMINATION PER WITH CODE APPROVI NEC 14, 250�94 CLAMP PER 250.50 AND 250.52 OF THE 2014 NEC. Typical 150-200 Amp Electrical Riser Diagram (updated 7-1-14) NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE PROVISIONS OF THE NFPA 70-17, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL CODES AND THE LOCAL POWER CO. H.B. DISC. b OWNER'S SUITE 12 ROUGH -IN FOR OPT. CLG. FAN/ LIGHT PRE -WIRE RECEPT111 FOR I ALARM V0SYSTEM C ------------- WP=@= GFI 80 -1 u') DEDICATED RECEPTACLE FOR MICROWAVE RANGE CAFE,,��, HOOD PER SPECS dbGFI r — --I --ill D.W.1 PATIO E)= =0 GFI I 0 V-Z V < I U.C. SWITCH KIT.) - SAL — FOR DISPOS QPGFI _j*N /L --OPT— C'\ REF ROUGH -IN FOR OPT.CLG.FAN/ LIGHT PRE -WI RE/ 6/ qp FAMILY RM GFI OT OPT. HAN� � PLUMBING RISER NOTE: PLUMBING RISER IS SCHEMATIC TO BE VERIFIED WITH PLUMBER VP ROUGH -IN FOR ,--'ROUGH-IN FOP'-, OPT. CLG. FAN/ OPT. CLG. FAN/ LIGHT PRE -WIRE LIGHT PRE -WIRE IF BEDROOM 2 BEDROOM 3 LIVOR ON (WW U P rbY ER- GFI GF1 @ 44" �W. JH A.F.F. I F — — — — — — — — — — — — 0 Cn GFI @ 44" r 0 U) GARAGE A.F.F. _j 0 Lli LLJ =&OOR (3 CL 1 IGF1 < (0 1 -2 CAR < LIJ t (M3 or- GARAGE lla/ VERIFY LOCATION L ELECTRICAL PANEL IL= AGFI 'R RI GATFON ----- 0 44" A.F.F. VERIFY METER H.B. LOCATION WITH BUILDER NTRY SCALE: NTS vf� \j ELECTRICAL PLAN - ELEV-B1 SCALE: Y4"=l'-O" CN CD C�4 C To the best of the Engineers knowledge, information and belief, the structural plans and specifications contained within these drawings comply with the 2020 Florda Building Code - Residential 7th Edition. Engineers signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. W CD 00 0 E - 8 "ll 0) _j 0 (0 C04 1, 0 C 0wo u- Lu' r-- r-L N C) '! LU 0- LL CL - �e '6' ra LL LL u:i to V) CL Lu Z _j 0 to 0 Lu X 0 w W 0 0, M _j M Z 00 Z N ce) _j (L X C) < Z W (D 00 < 0 �2 4-d Lij U to 0 V) IN! E 0 (n < 0 Z c" 0 LL_ E E CL c' 0 �i 0 01 0 < Z C�- E C'4 ro < 0 _(D .0 0 Z Z I Z < Cn < 0 Z zu Z C) C=) < < 0. A 0 0 0 C:) _17 C0 00 0 Q 0 L_ 0 0 E L_ 04 Cal 0 U') C14 LO (M oo 04 04 E 0 M Z E E 0 0 0 —1 'D cc < - 0 1 W _j JOB NO: 21-2029 SCALE : AS NOTED SHEErNO. 4 ATTIC VENTILATION CALCULATIONS - 131 (TRB) ATTIC VENTILATION REQUIRED UPPER VENTILATION PROVIDED 1/150 Rule 1/300 Rule Ridge Off -Ridge (No Upper Ventilators (Must Provide Upper Ventilators) Vent Amt Amt. Req.) (Ft.) Total Ventilation ATTIC Provided SPACE SQ. FT. Total SQ. SQ. FT. SQ. IN. of by Upper SQ. IN. of of vented IN. of of ventilation to SQ. IN. of SQ IN of Ventilators ventilation soffit ventilation vented be provided Ventilation ' ' Ventilation (See Elev) required needed required soffit by upper needed ventilators Main 22 2 Floor 1999 1919 274 960 69 480 606.0 330.0 276.0 (Zone 1) -NOTE** GENERAL CONTRACTOR MUST ENSURE THAT PROPER VENTILATION IS PROVIDED AT EAVES/SOFFITS AS REQUIRED BY FLORIDA BUILDING CODE 7TH EDITION (2020) RESIDENTIAL. ROOF PLAN — ELEV—B1 SCALE: Y4"=l'-O" Attic Ventilation Attic Ventilation to be in compliance with the Florida Building Code 7th Edition (2020) Residential R806. The Minimum net free ventilating area shall be 1/150 of the area of the vented space. The ventilating area may be reduced to 1/300 provided that at least 40% but no more than 50% of the required ventilation is provided in the upper portion of the space to be ventilated. Upper ventilators shall be located no more than 3 feet (measured vertically) below the ridge or highest point of the space, with the balance of the required ventilation provided by eave or cornice vents. -CALCULATIONS BASED ON THE FOLLOWING VALUES, SEE ROOF PLAN** (Values to be verified with Manufacturer Specifications) • OFF -RIDGE VENTS 138 SQ. IN, OF NET FREE AREA / UNIT • SOFFIT VENTS 7 SQ. IN. OF NET FREE AREA / SQ. FT. • STUCCO SOFFIT VENTS - 126 SQ, IN. OF NET FREE AREA / SQ. FT. *If not enough vented soffit is pirmAded due to fire protection, the contractor shall use the following approved vents: e LOMANCO DECK -AIR (Shingle Roof) - 9 SQ. IN. OF NET FREE AREA / FT. **Formula: (Sq. Ft. Soffit Needed) x 7 = (Sq. In. Needed) / 9 = (Linear Ft. of Deck -Air Needed) 7� C14 �_EWKOJ' C, 1pr ol To the best of the Engineers knowledge, information and belief, the structural plans and specifications contained within these drawings comply with the 2020 Florida Building Code - Residential 7th Edition. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineers signature and seal. 0 W 8 E co 8 00 * C�4 rT, 0 C) 00 Q) :1 LO oo w LL 0) (:0 '-_ 'Z _- 04 0 L-L L� a- a, C CU LL u_ u:' "i 1 (L uj 3: z 0 0 .5 0 l, LL — W (0 02- Y, 05 c�' _j o" c'3 < < Z IL 00 Ci LO C0 z _j CL w L/) 0 a N < d 3 < :D 0 0 in z W E3 0 .1 W U) Ln M E 8 co C13 W z z __j LL_ E 0 zP < , 0 E U 'z Z 0 0 r6 CL Mo. so CD E C'j ra t < z '0 < z :3 C/) z V 10 zo z z C' z Mj 0'. z < .0 C:) > M 0 00 0 0 > 0 C:) CD C r*.. 0 E CN z: 04 LL J cr) 0) LO 00 04 CSj 4i E r 0 z E cc cc E 0 0 'D < JOB NO: 21-2029 SCALE : AS NOTED SHEE7 NO. 5 I I T1 I . F� I I - I 1 11 1 1 111 11 1 1 if 1111111 111111 IRMIJI-11 I I I � I � 11 1 � 11 pill, - I I It I I I 111 11 v I I Irl I Irr-11 III , I I 3; C) CN -1 At C14 a) ck: C-) tl- 7N CD E E 0 LZ .2 LZ C> C14 C-4 C*4 U C> (D CIO 2'-q" , 6'-0" H.B.' M-11i 6'-0" T-1 0" 4'-2" 31-231, 8 L. Z-958" 6'-4" TYP @ 1 STORY U.N.O. ................ ......... ........ ........... ..... r u4- ................ .................... ............ 7;1�1 ... ............. I? CP 2'-9" 2'-8 10 it 01-0.1 co HVAC CHASE 0 IF vL C14 t tol I 1 BASED ON 10 EO LOCATION 10-107. .... ........... . CJ .......... 14-0 Ci - Ci Ci — - — - - 2'-6'W-6 -0 "xl' W/ (3) #TS E.W.--\ 17'-5Z' 8 36-6�1-- TYP @ 1 'STORY U.N.O. 0101, 1 7 60 A CP t �-j ... ....... S3 LO G ..................... ....... 7 ......... ... S3 3-1/2" MIN 3000 PSI CONU. 61-Ab t�-U TOP OF CONC./ PAVER TO BE 4- T-8" 4'-4" _4 HERNANDO COUNTY ONLY BELOW FIN. FLR. r. 3-1/2" MIN 2500 PSI CONC SLAB OVER 6 T-15' 8 4'-8" PROVIDE Y2" X 9' 2'-6'*x2-6"x1'-O" C� 3 1/2", I - Ir MIL VISQUEEN VAPOR BARRIER I RECESS FOR FRT. DOOR W/ (3) #5'S E.W ;t -3 1/2" SLOPE 8--63" 8 4 :I Jr I zo 4. LO —F �3 Ci I III D.W. III P 4 .3 III 111 1::',W.H./' I K cc S3 cc S3 % S3 STEPS AS REQUIRED PROVIDE 1 Y2" RECESS I I � F 7 I IL JiI3 PER FIELD FOR SGD. REFER TO -3. 1 1 � 11 r— — --111 1-§! 1:* MASON'S SLOPE FOR I I -,.z 7-4�" Lu 4L- �0 CONDITIONS I 1 11 lz WIDTH A 9) LO 4'-0" 25-6-1 1 111 20'-6'1 C14 1 EDGE OF r )LAB 2" (2) #5 VERTICAL = x 'y BEYOND WALL BARS M KITCHEN ISLAND LOW WALLS BUILDER TO PROVIDE I CHASETO ISLAND APPLIANCE PROTECTION t \. �3 WHEN REQUIRED PER FBC FILLED CELL 3000 PSI (D I NuiuATES W/ CJ CJ 19 19 rA CONC. GROUT FROM FT. TO BEAM 50 1`1 1,�,S3� W/ (1) #5 REBAR VERT ABOVE SLAB I C� I TYP @ ALL PLACES SHOWN zo U) TYP @ 1 STORY U.N.O. HOOKED FTG. DOWELS 5" EMBED W/ 25" EXT. ABOVE SLAB "GRADE 40 - 3 1/2" Q�- SLOPE, 1 I STEEL" 6PT I OPT. D 1:: 0, L--J I 20'-101-76" L J 4--7il-61" (2) #5 VERTICAL BARS un T 9 :r I DOOCKA T-529" 1 2- TYP @ 1 STORY U.N.O. 7-6" x 7-6" x 1'-0" W/ (3) #5'S E.W. - FOUNDATION PLAN MONO — ELEV-131 SCALE: Y4"= V-10" NOTE: • WHERE PROJECT IS TO BE LOCATED IN KNOWN RADON GAS PREVALENT AREAS, APPENDIX 7" OF THE FLORIDA BUILDING CODE 7TH EDITION (2020) RESIDENTIAL IS TO BE IMPLEMENTED. CONCRETE STRENGTH IN THESE AREAS TO BE A MINIMUM OF 3000 P.S.I. THEREFORE, ANY AND ALL NOTES ON THESE PLANS THAT INDICATED 2500 P.S.I. SHALL BE REPLACED WITH 3000 P.S.I. FOR THE CONCRETE STRENGTH • SEE SHEET SN FOR SOIL & TERMITE NOTES. BORATE / BORACARE TREATED LUMBER IS AN ALTERNATE TERMITE PROTECTION TO SOIL POISONING I V\/VVF PLACED IN —1/8" SAWCUT x 1/4 SLAB UPPER 1/3 OF SLAB THICKNESS WHERE OR FIBERMESH SHOWN ON REINF. SEE PLAN. FOUNDATION PLAN [17. LU v LU __j CONTROL JOINT DETAIL SCALE: 3/4" = V-0" —#5 CONTINUOUS REINF. SEE FND. FOR QUANTITY #5 X 25" X 25" CORNER BAR ONE FOR EA. HORIZ. REBAR, TYP. U.N.C. -Alternate: I he reinf. bars shall be cont. around corner by cold bending the bar w/ min. bar lap of 25". TYP. CORNER BAR DETAIL SCALE: 3/4" = V-0" Z::� CD 2! co k-EkA//fo�, N 4 Qj — OF W To the best of the Engineers knowledge, information and belief, the structural plans and specifications contained within these drawings comply with the 2020 Florida Building Code - Residential 7th Edition. Engineers signature and seal is only for the structural engineering portions of the drawing pages bearing Engineers signature and seaL CD W a co E r- 0 M 8 Cq C, C, U. Lo 0 62 - % u� - �; . r-_ p�_ _-Lu a- C14 0 (L M U_ LL L _j z 0 oi iffia C14 (c) LL W -i W W 0 ob < (D IL 00 z -i L0 Cl) U) 0 0 N < L) 0 (n z < CD U) V) CD 01 0 4�1 C") LU M 0 U) U E 8 UC21- < 0 t 14 CO 0 z U- E ca- 0 E Z< z co u q) E < 0- 0< E l5 0 0, I �z W. n:3 C/> -0 z Cn -0$ 0 z zu z W < .0 z C> CD co <1 X 0 % C:) 3: 00 0 0 (D 3� > 2 (.0 C: 0 r-1 %ft--o E 'qt Lo LO LO 00 CN 0) CN E Z� -E CN M z :3 E 0 V) 0) M C M FL 0 E 0 U -j a Co < a JOB NO: 21-2029 SCALE : AS NOTED SHEET NO. 6 RSH ENGINEERED ROOF PER ASCE 7-16 ROOF DESIGN ALLOWABLE COMPONENTS AND CLADDING WIND PRESSURES AND SUCTIONS FOR MEAN ROOF HEIGHT5 25 ft WIND SPEED (ULTIMATE) 140.0 MPH WIND SPEED (ALLOWABLE) 108.4 MPH EXPOSURE CATEGORY C EFFECTIVE WIND PRESSURE AND SUCTION (PSF) WIND AREA VALUE DENOTES PRESSURE H I P ROOF >20 TO 27 DEG. (SQ FEET) VALUE DENOTES SUCTION [4:12]-[6:12] a=4ft AREA ROOF 2e__ 2n 2r 3 3e 3r HIP -35.94 -49.57 -49.5 49.57 10 r GABLE -38.22 -38.22 60.99 -60.99 -60.99 -78.58 1 ----------- ROOF NAILING SCHEDULE/ NAILING ZONES (SHINGLE AND TILE): v ZONE 1: ASTM F1667 RSRS-01 (8d) NAILS @ 6" O.C. ON EDGE AND 6" O.0 IN FIELD ZONE 2e, 2n, 2r: ASTM F1667 RSRS-01 (8d) NAILS @ 4" O.C. ON EDGE AND 4"O.0 IN FIELD 611 ZONE 3, 3e, 3r: ASTM F1667 RSRS -01 (8d) NAILS @ 4" O.C. ON EDGE AND 4" O.0 IN FIELD ROOF SHEATHING: I G) SHINGLE: Y16" EXP. 1 (2y16) or 1Y32" EXP. 1 (33416) TILE: 1Y3j'EXP. 1 (3�116) NOTE: 1. PER CODE ASTM F1667 RSRS-01 REFERENCE TO 8d (2 %" x 0.113") NAILS 2. WHERE THE SHEATHING THICKNESS IS GREATER THAN 1V32", SHEATHING SHALL BE FASTENED WITH ASTM F1667 RSRS-03 10d (21/2" x 0.131") NAILS OR ASTM F1667 RSRS-04 (3"x.120") NAILS a=4ft 3. GABLES- DROP GABLE END & (1) ADDITIONAL DROPPED TRUSS 2x4 #2 SYP OUTLOOKER GABLE ROOF > 20 TO 27 DEG. RAFTER W/ BLOCKING @ 16- O.C. IF NO DROPPED GABLE END, ATTACH 2x4 #2 SYP BLOCKING [4:12]-[6:12] @ 16" O.0 FIRST 4 BAYS WITH (2) 12d NAILS EA. END, ATTACH ROOF SHEATHING TO RAFTERS W/ BLOCKING PER NAILING SCHEDULE. 3M D. IER 1SB -8" UPLIFT CONNECTION CROSS-REFERENCE MARK SIMPSON STRONG TIE USP MANUFACTURING, INC. 0 CONNECTOR CAPACITY FASTENERS CONNECTOR CAPACITY FASTENERS SYP SPF SYP SPF A META12 1420 9 - 10d x 1 1/2" HTA20 1870 1585 10 - 10d x 1 1/2" A (2) (2)META12 1875 (1)PLY 1795 (2)PLY 9 - 10d x 1 1/2" B HETA16 1810 9 - 10d x 1 1/2" HTA1 6 1870 1585 10 - 10d x 1 1/2" C H2.5A 565 535 10 - 8d RT7A 585 515 10 - 8d x 1 1/2" D H3 400 320 8 - 8d RT3 345 305 8 - 8d x 1 1/2" E META20 1450 7 - 1 Od x 1 1/2" HTA20-18 1625 1400 10 - 10d x 1 112" F HHETA20 2120 10 - 10d x 1 1/2" HTTA20 2375 11 - 10d x 1 1/2" G H10A 1040 1015 18 - 10d x 1 1/2" RT16A 1020 1160 9 - 1 Od x 1 1/2% 8-1 Old H FGTR 4725 3400 wl (18) 1/4" x 3" SDS WOOD SCREWS AND (2) 112" x 5"TITEN HD ACHOR BOLTS RFUS 7100 --- w/ (12) WS3 WOOD SCREWS AND (4) 3/4- x 6" WEDGE -BOLTS - J HTT5 4350 3740 5/8' ANCH. / (26) 10dxl-1/2" HTT5 5795 518" ANCH. /(26) 10d x1-1/2 K HD3B* 3130 3050 5/8"DIA. BOLTS TDX,2-TZ 3295 --- 2 - 5/8" DIA. BOLTS L VGT R/L 2225 1600 w/ (16) 1/4" x 3" SDS WOOD SCREWS AND HDU4-SDS2.5 w/ (10) 1/4" X 2 1/2" SDS WOOD SCREWS & (1) 5/8" ATR M VGT-F 4940 3555 wl (16) 1/4" x 3" SIDS WOOD SCREWS AND HDU4-SDS2.5 W/ (10) 1/4- x 2 1/2" SDS WOOD SCREWS & (1) 5/8' ATR LUS26 1165/1060 1005/915 8 - 1 Old x 3" JUS26 1000/1080** --- 8-10d P p HUS26 1320/3235 1335/2820 20 - 16d x 3 1/2" HUS26 2035/3400 --- (20)16d x 3-1/2" Q Q ]N HUS28 1760/4095 1720/3125 30 - 16d x 3 1/2" HUS28 2950/5090 --- 30d -1 6d x 3-1/2" R MTS12 990 860 14 - 10d x 1 1/2" MTW12 1195 1005 14-1 Od x 1-1 /2" S S VGT-M 4940 3555 w/ (16) 1/4" x 3" SDS WOOD SCREWS AND (1) 5/8" ATR EPDXIED W/ SIMPSON SET w/ 12" MIN. EMBEDMENT. T (2) LGT3 6570-M 6960-F 4730-M 5010-F w/ (24) 1/4" x 3" SDS SCREWS & (8) 3/8"x 5" TITEN HID (2 PLY) OR (52) 16D SINKERS FOR FRAME U MGT 3965 3330 22 -1 Od x (1) 5/8" ATR w/ 12" MUGT1 5 1 4175 1 122 -1 Od x (1) 5/8" ATR wl 12" EMBED W/ SIMPSON "SET" EMBED W/ USP CIA-7000C EPDXY EPDXY LGT2 14060-M 3770-FI3500-M 3240-F LUGT2 131 00-M 4520-F 131 00-M 3800-F 1 (14) 1/4" x 2 1/4" TITENS (2 PLY) OR (28) 16D SINKERS FOR FRAME (10) 1/4" x 3" WEDGE- BOLTS (2-PLY) OR (32) 16C SINKERS FOR FRAME "X" HTS 20 1310 1245 24-1 Od x 1 112" HTW20 1530 1285 24-1 Od x 1 1/2" Spi 555 535 10 - 10d SPT22 735 8 - 10d SP2 1010 1 605 1 12 - 10d SPT24 1090 1 1 12 - 10d HCP2 1 590 1 555 1 12-1 Old x 1 1/2" HHCP2 680 1 570 1 (20)1 Od x 1-1 /2" MINIMUM 3"MEMBER REACTIONS ARE FOR ROOF LOADS ONLY DO NOT DRIVE NAILS THROUGH THE TRUSS PLATE ON THE OPPOSITE SIDE OF THE TRUSS, WHICH COULD FORCE THE PLATE OFF OF THE TRUSS. ALL EPDXY ANCHORS SHALL USE SIMPSON "SET" OR USP CIA-7000C (SEE MANUFACTURES SPECS) NOTE: DOUBLE FELT REQ'D ON ROOF PITCHES 3/12 & LOWER. REVISED 12-02-20 LOADS - ROOF = L / 360 FLOOR = L / 480 W/ 3/8" MAX DEFLECTION FLOOR JOIST SPACING SHALL BE MAX OF 19.2" OC FOR HARDWOOD & TILE AREAS & 24" OC FOR CARPET AREA'S DROP HIP DETAIL, 2-0-0 MAXIUM SPACING ON VERTICALS OF (B) TRUSS 1-8-8 CLEAR GAP BETWEEN (B) TRUSSES (+/- 6-) 'FASTEN EACH (B) TRUSS WEB TO EACH (A) TRUSS TOP CHORD @ EVERY INTERSECTING POINT SHOWN ON THE HIP TRUSS SYSTEM BELOW. FASTEN TOP CHORDS OF EACH (B) TRUSS TO THE TOP CHORDS OF (A) TRUSSES AT EVERY OTHER INTERSECTING POINT ("). INTERSECTING POINT TO BE FASTENED WITH 2 - 16d COMMON NAILS OR 0.128" x 3" GUN NAILS. FASTEN BOTTOM CHORD OF (B) TRUSS TO TOP CHORD OF CARRIER TRUSS WITH THE SAME SPECIFIED COMMON NAILS OR GUN NAILS AT 48" OC. (+) IN LIEU OF PREFABRICATED HIP PLANING TRUSSES, (B) 2x4 SO. PINE #2 OR #2 PT, STICK LUMBER (LAID FLAT WISE) MAY BE USED. FOLLOW FASTENING SCHEDULE AS DEFINED FOR HIP PLANING TRUSSES. R1 STICK FRAMING SPLICING IS ALLOWED BETWEEN TRUSSES OR AT TRUSS INTERSECTIONS. SPLICING TO BE STAGGERED BETWEEN COMMON TRUSSES, NO CATS REQUIRED UNDER STICK FRAMING SPLICING. MINIMUM LENGTH OF STICK FRAMING TO BE 6-0" ON A HORIZONTAL PROJECTION. NOTE: SEE SHEET D1 FOR ROOF FRAMING DETAILS (2) - 12d TOENAILS EACH SIDE OF FLOOR TRUSS TO WALL OR BEAM BELOW. TYP. AT INTERIOR BEARING U.N.O. (A) OR 2 PLY ,ARRIER � 2 PLY CARRIER t -(A) x CONT LEDGER SEE SHEET D1 FOR ROOF FRAMING DETAILS FRAMING PLAN - ELEV-131 SCALE: Y4"=1'-O" % % 0 U.. 1� . it LU Ljj L 0 % % - 0 it, ;., To the best of the Engineers knowledge, information and belief, the structural plans and specifications contained within these drawings comply with the 2020 Florida Building Code - Residential 7th Edition. Engineers signature and seal is only for the structural engineering portions of the drawing pages bearing Engineers signature and seal. W CD 00 'ct, E co , CID 1- vt M 8 C, V _i C�l C6 U_ 0 C 0 coo u� u),-- rn r- r-L U- L� CL 04 CD 0- d - -! 11 _j LL LL u� M W _j C C) .13 it J 04, 0 P -5 -zz N 0 LL _j W W 0 cc (75 C� -;� 6 z IL a cc) _j u') ce) z 0: SQ 0 (14 < :3 L) < (L) U) z 0 1, _j W r I N C0 C, C14 < V) 0 al (1) 0 (a LU C) 0 LU C E U 8 < 0 tv, 4 C.0 co co z U_ c6 E C71- 0 E i 0 z< 0 CID U 0 a E 0 0 < X Z 04 M t 0 �z Cf) z 0. 0 10 z C/) 10- Z z 2. 2 < z z < 0 U z -0 C.0 01 0 C:) 00 0 0 "It > a) CN < > 0 C) 0 C co 0 E 04 C:) Lo LO LO 00 04 04 E E N 0 M z :3 E 0 In M E 0 0 0 _j _j JOB NO: 21-2029 SCALE : AS NOTED SHEET NO. 7 C'4 CN CD C14 C'4 C) C14 E 1.2 E 0 LZ E 49. C_.) 2 01 IV LZ C'4 CD 04 0 Cn GENERAL INSTALLATION N TES 1. Provide full mortar head and bed joints. 2. Shore filled lintels as required. 3. Installation of lintel must comply with the architectural and/or structural drawings. 4. J-Lintels are manufactured with 5-1/2" long notches at the ends to accommodate vertical cell reinforcing and grouting. 5. All lintels meet or exceed U360 vertical deflection, except lintels 17'-4" and longer with a nominal height of 8" meet or exceed 180. 6. Bottom field added rebar to be located at the bottom of the lintel cavity. 7. 7/32" diameter wire stirrups are welded to the bottom steel for mechanical anchorage. 8. Cast -in -place concrete may be provided in composite lintel in lieu of concrete masonry units. 9. Safe load ratings based on rational design analysis per ACI 318 and ACI 530 10. Product Approvals: Miami Dade County, Florida Nos.20-0630.16 and 20-0630.15. 11. The exterior surface of lintels installed in exterior concrete masonry walls shall have a coating of stucco applied in accordance with ASTM C-926 or other approved coating. 12. Lintels loaded simultaneously with veritcal (gravity and uplift) and horizontal (lateral) loads should be checked for combine loading with the following equation: Applied vertical load + Applied horizontal load Safe vertical load Safe horizontal load <1 .0 GENERAL CONCRETE LINTEL SCHEDULE 8F8-1B/1T 8F8-i i i Y.Y 11�� APPROVED LINTEL MANUFACTURERS: CASTE-CRETE, QUALITY, LOTTS JW It 8RF6-OB11T Q 0 0 0 0 0 0 0F14-113/1 8RF14-0B/1T 8F16-J 8F16-1B/1T 0 0 8F20-0B/1T 81`44 1B/1T8F40 1B/1T 8RF400B/1T 8F32 1B/1T (a e III \Z7 1 (9 FORM & GROUT SOLID r < 9 LU _J 0 0 #5 BAR CONT. 8F12-1B/1T 1:0 V' LINTEL DETAIL SCALE Jill iiiiii i Jill 1111 TYPE DESIGNATION REBAR IN. AT TOP (1) RECI'D ALTERNATE POWERS F = FILLED WITH GROUT/ U = UNFILLED R RECESSED -1/2" CLEAR STEEL LINTEL 4 A _i_'Lll QTY. OF #5 A REBAR @ BOTTOM OF LINTEL CAVITY 4 M.U. #5REBARATTOP v uJ MIN. (1) REJ 1-1/2" CLEAR B/1T 6t-16- M 0 Z GROUT > '6 ZD �7 L 1' QUANTITY OF tNOMINAL. -#5 REBAR AT o <1 X: ul WIDTH #5 REBAR AT BOTTOM OF L l K Lu Lu 0 TOP 0 "*-BOTTOM LINTEL CAVITY Lu Cn- 0 U l X W 'Er NOMIJ 0 L) 0 HEIGHT REINFORCING Ir <l < X 7-5/8"ACTUAL �PROVIDED IN LL d Lu > > Z 8" NOMINAL WIDTH ' LINTEL b 3: CN 1 0 'P L <1 #5 REBAR AT BOTTO AS INDICATED (VARIES) 0 Lin Cr I MATERIALS 16 GAUGE POWERS T_?c__prac­asT7nteIs = 3500 psi. STEEL BOXED LINTEL 2. fc prestressed lintels = 6000 psi. 3. grouted per ASTM C476 fg = 3000 psi w/ POWERS STEEL BOXED LINTEL NOTES (ALT.) 4. maximum 3/8" aggregate and 8" to 11" slump. 5. Concrete masonry units (CMU) per ASTM C90 w/ ONLY IF NOTED ON LINTEL PLAN minimum net area compressive strength = 1900 psi. 6. Rebar per ASTM A615 Grade 60. 1. Refer to manufacturers specifications for installation. Prestressing strand per ASTM A416 grade 2. Contractor to provide proper protection of lintel to prevent rusting. 7. 270 low relaxation. Refer to manufacturer's specifications. 7/32 wire per ASTM A51 0. 3. If lintel is scratched or damaged refer to Powers Steel for repair. 8. Mortar per ASTM C270 type M or S. 4. Lintel depth to match precast depth. One #5 Bar required at top see lintel plan/details for bottom steel required. 5. A bonding agent must be applied to the Steel Box lintels prior to L�NTEL MINIMUM DEPTHS ARE CALLED,OUT ON LINTEL PLAN. IF CONTRACTOR INSTALLS A DEEPER L NTEL THAN INDICATED ON THE PLAN DOING THIS INCREASES THE STRENGTH OF THE LINTEL AND IS applying the cementitil coating. See contractor specifications APPROVED WITHOUT ENGINEERING LETTER. IF A SMALLER LINTEL IS INSTALLED CONTACT E.O.R. FOR APPROVAL. (SEE LINTEL PLAN FOR SCHEDULE) LINTEL PLAN NOTES: 1. THIS PLAN IS TO BE USED FOR STRUCTURAL INFORMATION ONLY. 2. UNLESS NOTED OTHERWISE ALL LINTEL DEPTHS ARE TO BE ASSUMED TO BE 16" MINIMUM DEPTH. 3. THE NUMBER OF COURSES OF MASONRY REQUIRED BETWEEN THE LINTEL & THE BOND BEAM SHOULD BE COORDINATED WITH THE ELEVATION DRAWINGS 4. THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING THE PROPER LINTEL HEIGHT. 5. LINTELS AT GARAGE DOOR OPENING ARE MINIMUM DEPTH REQUIRED FOR THE DESIGN LOADS. THE DEPTH MAY BE INCREASED IF REQUIRED FOR PROPER LINTEL HEIGHT,G.C. COORDINATE. POWER STEEL LINTEL IS AN ADEQUATE SUBSTITUTION @ ALL LOCATIONS UNLESS NOTED OTHERWISE AT OPENING LOCATION F 4'-0" LL E 5'- 10" L L LINTEL PLAN - ELEV-Bl SCALE: Y4"=1i ic V Z::� CID a: J To the best of the Engineers knowledge, information and belief, the structural plans and specifications contained within these drawings comply with the 2020 Florida Building Code - Residential An Edition. Engineers signature and seal is only for the structural engineering portions of the drawing pages bearing Engineers signature and seal. 0 W 0 E M 8 Co Co (0 l l cc,:, C� -LL 0 W l lr�- 04 C) U- ul a- CL Lu _J 0 0 r- ca C:, C.� (0 0 J LL _J 0 r- (n G) Co M Z LL 00 d ') Z� , C') _J CL X S9 0 3 - < L 0 " W Z ' 27 10 27 0 Ci 0 ::D U3 E 0 0 < C:) W Z C13 0 55 Z < _J E E0 .0 " - ZO 0 � J M wl� �0 0� . U0 0 0� Z E cli M t 0 0 Z Z C < 0 < 0 0 Z Z 0 < Z <' om 50 0_ 2< �u W EE '0 CD OE Z 1< C:) > 0 00 0 0 ql:t a) C%4 0 J 0 C C 0 E L_ ill J J Lo 1: N LO co m LO 00 E CN 0 Z M Z E 10 CAI cn C ca E 0 Z cc FL - 0 _J < 0 JOB NO: 21-2029 SCALE : AS NOTED SHEE7 NO. 8 qu, -31- C> C14 C> M C14 C) C Q. E �2 0 LZ CS .2 LZ C14 CL C14 CE -2 C) E3 NOTE: BORATE/ SENTRA CON SYSTEM APPLIED TO ALL FRAME MEMBERS WITHIN 24" A.F.F. 1) METHOD OF TREATMENT SHALL BE APPROVED BY THE GOVERNING JURISDICTION "LIQUID BORATE OR BOR-A-COR" PRODUCT METHODS MUST BE DETERMINED AT PERMIT STAGE. 2) PRESSURE TREATED LUMBER THAT HAS BEEN CUT OR DRILLED THAT EXPOSES UNTREATED PORTIONS OF WOOD ARE REQUIRED TO BE FIELD TREATED TO PREVENTINSECT INFESTATION. ATTENTION: CHEMICAL CHANGES IN PRESSURE TREATED WOODS AS OF DECEMBER 31ST, 2003, CHROMATED COPPER ARSENATE CCA-C) WILL NO LONGER BE PRODUCED FOR RESIDENTIAL OR GENERAL CONSUMER USE. SEVERAL NEW PRESSURE TREATED WOOD ALTERNATIVES HAVE BEEN CREATED TO REPLACE CCA-C. MANY OF THE NEW PRESSURE TREATED WOODS USE CHEMICALS THAT ARE CORROSIVE TO STEEL. IT IS THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THE TYPE OF WOOD TREATMENT AND TO SELECT APPROPRIATE CONNECTORS THAT RESIST CORROSION. FOR EXAMPLE, ACQ-C, ACQ-D,CBA-A, ORCA-B REQUIRE HOT -DIPPED GALVANIZED OR STAINLESS STEEL FASTENERS. DOT SODIUM BORATE (SBX) DOES NOT. REQUIRED SAFETY GLAZING IN HAZARDOUS LOCATIONS (RE: FBRC R308.4) R308.3 HUMAN IMPACT LOADS. INDIVIDUAL GLAZED AREAS INCLUDING GLASS MIRRORS IN HAZARDOUS LOCATIONS SUCH AS THOSE INDICATED AS DEFINED IN SECTION R308.4 SHALL PASS THE TEST REQUIREMENTS OF SECTION R308.3.1. GLAZING SHALL BE TESTED IN ACCORDANCE WITH CPSC 16 CFR, PART 1201 CRITERIA FOR CATEGORY I OR CATEGORY 11 AS INDICATED IN TABLE R308.3.1(1). EXCEPTIONS: 1. POLISHED WIRED GLASS FOR USE IN FIRE DOORS AND OTHER FIRE RESISTANT LOCATIONS SHALL COMPANY WITH ANSI Z97.1-14 2. LOUVERED WINDOWS AND JALOUSIES SHALL COMPANY WITH SECTION R308.2 R308.4 HAZARDOUS LOCATIONS. THE FOLLOWING SHALL BE CONSIDERED SPECIFIC HAZARDOUS LOCATIONS FOR THE PURPOSE OF GLAZING: 1. GLAZING IN SWINGING DOORS EXCEPT JALOUSIES. 2. GLAZING IN FIXED AND SLIDING PANELS OF SLIDING DOOR ASSEMBLIES AND PANELS IN SLIDING AND BIFOLD CLOSET DOOR ASSEMBLIES. 3. GLAZING IN STORM DOORS. 4. GLAZING IN ALL UNFRAMED SWINGING DOORS. 5. GLAZING IN DOORS AND ENCLOSURES FOR HOT TUBS, WHIRLPOOLS, SAUNAS, STEAM ROOMS, BATHTUBS, AND SHOWERS. GLAZING IN ANY PART OF A BUILDING WALL ENCLOSING THESE COMPARTMENTS WHERE THE BOTTOM EXPOSED EDGE OF THE GLAZING IS LESS THAN 60 INCHES (1524MM) MEASURED VERTICALLY ABOVE ANY STANDING OR WALKING SURFACE. 6. GLAZING, IN AN INDIVIDUAL FIXED OR OPERABLE PANEL ADJACENT TO A DOOR WHERE THE NEAREST VERTICAL EDGE IS WITHIN A 24-INCH(610MM) ARC OF THE DOOR IN A CLOSED POSITION AND WHOSE BOTTOM EDGE IS LESS THAN 60 INCHES (1524MM) ABOVE THE FLOOR OR WALKING SURFACE. 7. GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL, OTHER THAN THOSE LOCATIONS DESCRIBED IN ITEMS 5 AND 6 ABOVE, THAT MEETS ALL OF THE FOLLOWING CONDITIONS: 7.1 EXPOSED AREA OF AN INDIVIDUAL PANE GREATER THAN 9 SQUARE FEET (0.836 M2). 7.2 BOTTOM EDGE LESS THAN 18 INCHES (457 MM) ABOVE THE FLOOR. 7.3 TOP EDGE GREATER THAN 36 INCHES (914 MM) ABOVE THE FLOOR. 7.4 ONE OR MORE WALKING SURFACES WITHIN 36 INCHES (914 MM) HORIZONTALLY OF THE GLAZING. 8. ALL GLAZING IN RAILINGS REGARDLESS OF AN AREA OR HEIGHT ABOVE WALKING SURFACE. INCLUDED ARE STRUCTURAL BALUSTER PANELS AND NONSTRUCTURAL IN FILL -PANELS. 9. GLAZING IN WALLS AND FENCES ENCLOSING INDOOR AND OUTDOOR SWIMMING POOLS, HOT TUBS AND SPAS WHERE THE BOTTOM EDGE OF THE GLAZING IS LESS THAN 60 INCHES (1524 MM) ABOVE A WALKING SURFACE AND WITHIN 60 INCHES (1524 MM) HORIZONTALLY OF THE WATER'S EDGE. THIS SHALL APPLY TO SINGLE GLAZING AND ALL PANES IN MULTIPLE GLAZING. 10. GLAZING ADJACENT TO STAIRWAYS, LANDINGS, AND RAMPS WITHIN 36 INCHES (914 MM) HORIZONTALLY OF A WALKING SURFACE WHEN THE EXPOSED SURFACE OF THE GLASS IS LESS THAN 60 INCHES (1524 MM) ABOVE THE PLANE OF THE ADJACENT WALKING SURFACE. 11. GLAZING ADJACENT TO STAIRWAYS WITHIN 60 INCHES (1524 MM) HORIZONTALLY OF THE BOTTOM TREAD OF A STAIRWAY IN ANY DIRECTION WHEN THE EXPOSED SURFACE OF THE GLASS IS LESS THAN 60 INCHES (1524 MM) ABOVE THE NOSE OF THE TREAD. EXCEPTION: THE FOLLOWING PRODUCTS, MATERIALS AND USES ARE EXEMPT FROM THE ABOVE HAZARDOUS LOCATIONS: 1. OPENINGS IN DOORS THROUGH WHICH A 3-INCH(76 MM) SPHERE IS UNABLE TO PASS. 2. DECORATIVE GLASS IN ITEMS 1, 6 OR 7. 3. GLAZING IN SECTION R308.4.2, ITEM 2-EXCEPTIONS, WHEN THERE IS AN INTERVENING WALL OR OTHER PERMANENT BARRIER BETWEEN THE DOOR AND THE GLAZING. 4. GLAZING IN SECTION R 308.4.2, ITEM 3, WHERE ACCESS THROUGH THE DOOR IS TO A CLOSET OR STORAGE AREA 3 FEET (914 MM) OR LESS IN DEPTH. GLAZING IN THESE APPLICATIONS SHALL COMPANY WITH SECTION R308.4.3. 5. GLAZING IN SECTION R308.4.3, ITEM 2-EXCEPTIONS, WHEN A PROTECTIVE BAR IS INSTALLED ON THESE ACCESSIBLE SIDE(S) OF THE GLAZING 36 INCHES ± 2 INCHES (914 ± MM 51 MM) ABOVE THE FLOOR. THE BAR SHALL BE CAPABLE OF WITHSTANDING A HORIZONTAL LOAD OF 50 POUNDS PER LINEAR FOOT KG/M) WITHOUT CONTACTING THE GLASS AND BE A MINIMUM OF 1 X INCHES (38 MM) IN CROSS SECTIONAL HEIGHT. 6. OUTBOARD PANES IN INSULATING GLASS UNITS AND OTHER MULTIPLE GLAZED PANELS IN SECTION R308.4.3, ITEM 3-EXCEPTIONS, WHEN THE BOTTOM EDGE OF THE GLASS IS 25 FEET (7620 MM) OR MORE ABOVE GRADE, A ROOF, WALKING SURFACES, OR OTHER HORIZONTAL [WITHIN 45 DEGREES (0.79 RAD) OF HORIZONTAL] SURFACE ADJACENT TO THE GLASS EXTERIOR. 7. MIRRORS AND OTHER GLASS PANELS MOUNTED OR HUNG ON A SURFACE THAT PROVIDES A CONTINUOUS BACKING SUPPORT. 8. SAFETY GLAZING IN SECTION R308.4, IS NOT REQUIRED WHERE: 8.1 THE SIDE OF STAIRWAY, LANDING OR RAMP HAS A GUARDRAIL OR HANDRAIL, INCLUDING BALUSTERS OR IN -FILL PANELS, COMPLYING WITH THE PREVISIONS OF; AND 8.2 THE PLANE OF THE GLASS IS GREATER THEN 18 INCHES (457 MM) FROM THE RAILING. 1. SPECIFICATIONS 1. 1. CONSTRUCTION: 1. 1. 1. ACI 318-14 BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE 1.1.2. ACI 530-13, ASCE 5/TMS 402-16 & ACI 530.1-13, ASCE 6/TMS 602-16 SPECIFICATIONS FOR MASONRY STRUCTURES, 1.1.3. ASTM C270-14A, C90-14 & C91-05 SPECIFICATIONS FOR MASONRY STRUCTURES 1.1.4. NATIONAL DESIGN SPECIFICATIONS (NDS) FOR WOOD CONSTRUCTION, 2018 EDITION, AND ALL ACCOMPANYING SUPPLEMENTS. 1.1.5. FLORIDA BUILDING CODE 7TH EDITION (2020) RESIDENTIAL 1.1.6. "MANUAL OF STEEL CONSTRUCTION, ALLOWABLE STRESS DESIGN', BY THE AMERICAN INSTITUTE OF STEEL CONSTRUCTION, (AISC) 15TH EDITION. 1.1.7. "DESIGN SPECIFICATION FOR LIGHT METAL PLATE CONNECTED WOOD TRUSSES" BY THE TRUSS PLATE INSTITUTE TR11-14. 1.2. DESIGN: 1.2.1. ACI 301-16 BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE 1.2.2. ACI 530-16, ASCE 5/TMS 402-16 & ACI 530.1-16, ASCE 6/TMS 602-16 SPECIFICATIONS FOR MASONRY STRUCTURES. 1.2.3. ASTM C270-14A, C90-14 & C91-05 SPECIFICATIONS FOR MASONRY STRUCTURES 1.2.4. NATIONAL DESIGN SPECIFICATIONS (NDS) FOR WOOD CONSTRUCTION, 2018 EDITION, AND ALL ACCOMPANYING SUPPLEMENTS. 1.2.5. PLYWOOD DESIGN SPECIFICATIONS (APA) 1.2.6. FLORIDA BUILDING CODE (FBC) 7TH EDITION (2020) AND FLORIDA BUILDING CODE 7TH EDITION RESIDENTIAL (FBCR) 1.3. SHOP DRAWINGS: 1.3.1. THERE SHALL NOT BE ANY DEVIATIONS FROM THESE DESIGN PLANS BY OTHERS DURING THE PREPARATION OF SHOP DRAWINGS WITHOUT WRITTEN APPROVAL FROM THE ENGINEER OF RECORD. 1.3.2. ALL SHOP DRAWINGS ARE TO BE SUBMITTED TO THE ENGINEER OF RECORD PRIOR TO THE COMMENCEMENT OF CONSTRUCTION. 1.3.3. ALL ROOF AND FLOOR TRUSS SHOP DRAWINGS ARE TO BE SIGNED AND SEALED BY A FLA. REG. PE. AND SHALL INCLUDE: DRAWINGS AND CALCULATIONS, REACTIONS AND BEARING POINTS, BRACING REQUIREMENTS, AND CONNECTIONS TO SUPPORTING TRUSS MEMBERS. 2. DESIGN LOADS 2.1. DEAD LOADS: 2.1.1. UNIT WEIGHT OF SOIL, COMPACTED: 120 PCF 2.1.2. UNIT WEIGHT OF REINFORCED CONCRETE: 150 PCF 2.1.3. UNIT WEIGHT OF 8" C.M.U. BLOCK: 55 PSF 2.1.4. 1ST FLOOR SUPERIMPOSED LOAD: 20 PSF 2.1.5. UNIT WEIGHT OF 2x4 PARTITION WALLS: 11 PSF 2.1.6. UNIT WEIGHT OF 2x6 BEARING WALLS: 12 PSF 2.1.7. BALCONIES & DECKS: 15 PSF 2.1.8. TILE ROOF TOPCHORD: 15 PSF BOTTOM CHORD: 10 PSF 2.1.9. SHINGLE ROOF TOPCHORD: 7 PSF BOTTOM CHORD: 10 PSF 2.1.10. FLOOR TRUSSES 15 2.2. LIVE LOADS: 2.2.1 SIDEWALK AND DRIVEWAY LOAD: 250 PSF 2.2.2 GARAGELOADS: 40 PSF 2.2.3 PARTITIONED ROOMS: 40 PSF 2.2.4. BALCONY AND DECKS: 60 PSF-UNDER 100 sq. ft. 2.2.5. STAIRWAYS AND LANDINGS: 40 PSF 2.2.6. SLEEPING ROOMS: 30 PSF 2.2.7. FLOOR TRUSS TOP CHORD MINIMUM: 40 PSF 2.2.8. ROOFTRUSS TOP CHORD MINIMUM: 20 PSF BOTTOM CHORD (ATTIC W/O LIMITED STORAGE): 10 PSF (NON -CONCURRENT) BOTTOM CHORD (ATTIC W/ LIMITED STORAGE): 20 PSF 2.3. RAILING LOADS: 2.11. ALL RAILING AND GUARD RAIL SYSTEM'S ARE TO BE DESIGNED TO WITHSTAND A CONCENTRATED LOAD OF 200 POUNDS APPLIED AT ANY POINT AND IN ANY DIRECTION ON THE RAILING. 2.3.2. ALL RAILING AND GUARD RAIL SYSTEM'S ARE TO BE DESIGNED TO WITHSTAND A HORIZONTAL LOAD OF 50 PLF ON THE GUARDRAIL AND A SIMULTANEOUS LOAD OF 100 PLF APPLIED VERTICALLY DOWNWARD AT THE TOP OF THE GUARDRAIL 2.3.3. GUARDRAIL SYSTEM SHALL BE DESIGNED TO WITHSTAND 2001b CONCENTRATED HORIZONTAL LOAD APPLIED ON 1 SQ. FT. AT ANY POINT IN THE SYSTEM. 2.3.4. 2.3.1.,2.3.2 & 2.3.3. ARE NOT REQUIRED TO BE APPLIED SIMULTANEOUSLY, BUT EACH SHALL BE APPLIED TO PRODUCE THE MAXIMUM STRESSES IN THE MEMBER COMPONENTS. 2.4. WIND LOADS: 2.4.1. WIND DESIGN TO BE CONDUCTED IN ACCORDANCE WITH SECT. R301.2 OF THE FLORIDA BUILDING CODE 7TH EDITION (2020) RESIDENTIAL, AND CONDUCTED BASED ON A 140 MPH 3 SECOND GUST, EXPOSURE "C", IMPORTANCE FACTOR "I" = 1.0. ENCLOSED BUILDING 2.4.2. NET UPLIFT DEAD LOADS - 10 PSF SHINGLE, 15 PSF TILE 2.4.3. WIND LOAD DETERMINATION BASED ON ASCE/SEI 7-16 2.5. DEFLECTIONS: 2.6.1. FLOOR TRUSSES SHALL LIMIT DEFLECTION TO U480TIMES THE SPAN FOR LIVE LOADS AND U240 TIMES THE SPAN FOR TOTAL LOAD. 3. DESIGN METHOD 3.1. LOAD FACTOR DESIGN: 3.1.1. THE LOAD FACTOR DESIGN METHOD WAS USED TO DESIGN: CAST -IN -PLACE CONCRETE SLABS AND FOOTINGS 3.2. SERVICE LOAD DESIGN: 3.2.1. THE SERVICE LOAD DESIGN METHOD WAS USED TO DESIGN: MASONRY WALLS AND LINTELS INTERIOR AND EXTERIOR WOOD FRAMING AND SHEATHING STAIRS AND FLOOR FRAMING ROOF FRAMING, SHEATHING AND UPLIFT 3.3. LOAD COMBINATIONS FOR LRFD DESIGNS: 3.3.1. THE FOLLOWING LOAD COMBINATIONS WERE DESIGNED FOR: TOTAL DL + FLOOR LL + ROOF LL TOTAL DL + FLOOR LL + WL TOTAL DL + WL 3.3.2. ALL ROOF AND FLOOR TRUSSES SHALL BE DESIGNED TO RESIST THE WORST LOAD COMBINATION RESULTING IN THE MAXIMUM STRESSES PLACED ON THAT COMPONENT. BOTH PARTIAL, FULL, AND ALTERNATING SPAN LOADING ARE TO BE CONSIDERED, 3.4. DESIGN ASSUMPTIONS: 3.4.1. ALL FOUNDATIONS ARE CENTERED UNDER SUPPORTED COLUMNS AND WALLS UNLESS SHOWN OTHERWISE IN THE DESIGN PLANS. 4. MATERIALS 4.1. REINFORCING STEEL: 4.1.1. REINFORCING STEEL SHALL BE ASTM A615 / A615M-12 MIN. GRADE 40, fy = 40 Ksi 4.1.2. LAP SPLICE SHALL BE AS FOLLOWS: #5 BAR 25", #4 BAR 20", #3 BAR 20". 4.1.3. ALL DIMENSIONS PERTAINING TO THE LOCATION OF REINFORCING ARE TO THE CENTERLINE OF EACH BAR EXCEPT WHERE THE COVER DIMENSION IS SHOWN TO THE FACE OF THE CONCRETE. 4.1.4. REINFORCING DETAIL DIMENSIONS ARE OUT TO OUT OF BARS. 4.1.5. REINFORCING MECHANICAL COUPLERS ARE TO DEVELOP 125% OF THE REQUIRED YIELD STRENGTH OF THE BAR AND ARE TO BE APPROVED BY THE ENGINEER OF RECORD. 4.1.6. DESIGN COVER REQUIREMENTS: C-1-P CONCRETE FORMED AGAINST EARTH: T' C-l-P CONCRETE EXPOSED TO EXTERIOR: 2" C-I-P CONCRETE NOT EXPOSED: 1 XF. GROUT FILLED MASONRY: Y4" 4.1.7. WELDED WIRE FABRIC (WWF): ASTMA-185/A185M-14 4.1.8. DETAIL REINFORCEMENT IN ACCORDANCE WITH ACI 318-14 (STRUCTURAL CONCRETE) ACI 530-16 (MASONRY STRUCTURES) 4.2. CONCRETE: 4.2.1. CONCRETETYPE MIN. 28 DAY DESIGN (fc) MODULES OF ELASTICITY DESIGN (E) C-1-P CONCRETE (NORMAL WEIGHT) 2,500 Psi 2,850 Ksi C-1-P CONCRETE (NORMAL WEIGHT) HERNANDO CO. ONLY 3,000 Psi 3,122 Ksi C-l-P GROUT 3,000 Psi 3,122 Ksi 4.2.2. CONCRETE SHALL CONSIST OF 1" MAXIMUM AGGREGATE CONCRETE MIX WITH SLUMP BETWEEN 6" AND 7" AT TIME OF PLACEMENT. SEE SPECIFICATIONS FOR ADDITIONAL CRITERIA. 4.2.3. GROUT SHALL CONSIST OF PEA ROCK (3/8' MAXIMUM AGGREGATE) CONCRETE MIX WITH SLUMP BETWEEN 8" AND 10" AT TIME OF PLACEMENT. SEE SPECIFICATIONS FOR ADDITIONAL CRITERIA. 4.2.4. CONSTRUCTION JOINTS WILL BE PERMITTED 4.2.5. METHOD OF CONCRETE FORMING, PLACEMENT AND CURING SHALL BE CONDUCTED IN ACCORDANCE WITH THE SPECIFICATIONS AS STATED. 4.2.6. EARTH SUPPORTED SLABS (EXCLUDING EXTERIOR WALKWAYS & DRIVEWAYS): 31/2" MIN. THICKNESS W/ MIN. REINFORCEMENT OF 6.0 x 6.0 W/ 1.4 x 1.4 WWF @ MID -DEPTH OF SLAB. FIBER MESH PER DESIGN MIX MAY BE USED I.L.O. WWF @ CONTRACTORS DISCRETION. 4.3. CONCRETE MASONRY: 4.3.1. FILLED CELLS W/ (1) #5 BAR SHALL BE LOCATED PER PLAN. 4.3.2. LOAD BEARING CONCRETE MASONRY BLOCK SHALL BE ASTM C90-14, TYPE 11 NON -MOISTURE CONTROLLED. 4.3.3. ALL CELLS & CAVITIES BELOW GRADE WILL BE FILLED W/ CONCRETE IN ALL STEM WALLS. 4.3.4. THE AGGREGATE STRENGTH OF THE BLOCK AND MORTAR SHALL BE F'm = 2,000 PSI MINIMUM. 4.3.5. METHOD OF CONCRETE MASONRY PLACEMENT AND CONSTRUCTION SHALL BE CONDUCTED IN ACCORDANCE WITH THE SPECIFICATIONS AS STATED. 4.3.6. MORTAR SHALL BE ASTM C270 TYPE "S" FOR ALL MASONRY CONSTRUCTION. 4.4. STRUCTURAL LUMBER: 4.4.1.1. INTERIOR LOAD BEARING WALLS SPF #2 ALL EXTERIOR FRAMING SPF #2 4.4.1.2. ALL FRAME WALLS TO BE CONSTRUCTED USING SPF #2, STUD QUALITY OR BETTER 4.4.1.2.1 ALL HEADER, BEAMS, COLUMNS ETC. TO BE SYP #2 OR BETTER 4.4.2. ALL PLYWOOD USED FOR EXTERIOR APPLICATIONS SHALL BE APA RATED STRUCTURAL SHEATHING 15132" EXP 1 OR 7/16" STRUCTURAL 1, U.N.O. 4.4.3. ALL PLYWOOD USED FOR INTERIOR APPLICATIONS SUCH AS SUB FLOORING AND SHEAR WALLS SHALL BE APA RATED SHEATHING EXP 1 U.N.O. 4.4.4. IF OSB BOARD IS TO BE USED IN PLACE OF PLYWOOD IS TO HAVE SIMILAR OR GREATER SECTION PROPERTIES, 4.4.5. ONLY STRUCTURAL LUMBER TO BE USED FOR AN EXTERIOR APPLICATION. WOOD IN CONTACT WITH CONCRETE IS TO RECEIVE A STANDARD GRADE PRESSURE TREATING. 4.4.6. WHEN PRE ENGINEERED TRUSSES ARE CALLED FOR ON THE PLANS THE MANUFACTURER IS TO SUBMIT SHOP DRAWINGS TO THE ENGINEER OF RECORD. 4.4.7. DESIGN, FABRICATE AND ERECT WOOD TRUSSES IN ACCORDANCE WITH THE -DESIGN SPECIFICATION FOR LIGHT METAL PLATE CONNECTED WOOD TRUSSES" BY THE ANSI/TPi 1-2014, BCSI 4.4.8. UNTREATED WOOD SHALL NOT BE IN DIRECT CONTACT WITH CONCRETE. SEAT PLATES SHALL BE PROVIDED AT BEARING LOCATIONS WITHOUT WOODEN TOP PLATES. 4.4.9. ALL EXTERIOR FRAME WALLS SHALL BE STUCCO FINISH- 7/8" STUCCO FINISH PER ASTM C. 926, APPLY 3 LAYERS W/ TOTAL THICKNESS 7/8" OVER METAL LATH. FIRST 2 LAYERS 3/8" THICK EACH. 3RD LAYER 1/8"THICK 4.4.10. INSTALLATION OF EXTERIOR LATHING & FRAMING SHALL COMPLY TO ASTM C 1063 PER FLORIDA CODE R703.7 4.5. FASTENERS AND TIE DOWNS: 4.5.1. FASTENERS AND TIE DOWNS SHALL CONSIST OF BUT ARE NOT LIMITED TO: SHAPES, ANGLES, CHANNELS: ASTM A36/36M 05 Fy = 36 Ksi ROUND METAL PIPE: ASTM A53, GRADE B Fy = 35 Ksi SQUARE METAL TUBING: ASTM A500, GRADE B Fy = 46Ksi HIGH STRENGTH BOLTS: ASTM A325 MACHINE BOLTS: GALVANIZED ASTM A307 4.5.2. SHEET METAL ACCESSORIES SHALL CONFORM TO: Fy = 33KsiWITH G90 GALVANIZED COATING IN ACCORDANCE WITH ASTM A525-87. 4.5.3. NAILS SHALL CONSIST OF: COMMON WIRE NAILS WITH MINIMUM DIAMETER AS FOLLOWS: 8d = 0.131", 10d = 0.148", 12d = 0.148", 16d = 0.162". 4.5.4. ALL FASTENERS AND TIE DOWNS EMBEDDED IN CONCRETE OR USED IN AN EXTERIOR APPLICATION ARE TO RECEIVE AN ANTI -CORROSIVE COATING BY MANUFACTURER PRIOR TO INSTALLATION. 4.5� 5. ALL FASTENERS AND TIE DOWNS ARE TO PROVIDE THE UPLIFT CAPACITY CALLED FOR IN THE PLANS ARE A MINIMUM. 4.5.6. ALL FASTENER TIE DOWNS, BEAM HANGERS, JOIST HANGERS, AND FLOOR TRUSS STRAPPING ARE TO BE INSTALLED IN ACCORDANCE WITH THE PLANS AND SPECIFICATIONS. 4.5.7. CONCRETE EMBEDDED'XBOLTS USED FOR UPLIFT ARE TO BE WET SET PRIOR TO INITIAL SET OF THE CONCRETE, SPACING AND ALIGNMENT ARE TO BE IN ACCORDANCE WITH THE DESIGN PLANS, U.N.C. ALTERNATES TO "J" BOLTS ARE NOTED ON PLANS. 4.5.8. CONCRETE EMBEDDED TIE DOWNS USED FOR TRUSS AND WALL UPLIFT ARE TO BE PLACED AROUND EMBEDDED REINFORCING PRIOR TO OR WHILE PLACING GROUT. 4.6. MICRO -LAM LUMBER: 4.6.1. MICRO -LAM STRESS GRADES SHALL PROVIDE THE FOLLOWING MINIMUM PROPERTIES: E = 2,000,000 PSI Fb= 2,950 PSI Ft 1,850 PSI Fc 500 PSI (PERPENDICULAR) Fc= 2,700 (PARALLEL) 4.7. STEEL: Fv = 285 PSI 4.7.1. INSTALLATION OF ALL STEEL TO BE PERFORMED BY AN EXPERIENCED, QUALIFIED STEEL ERECTOR. 4.7.2. FABRICATE AND ERECT ALL STRUCTURAL STEEL IN ACCORDANCE WITH A.I.S.C. "SPECIFICATION FOR THE DESIGN, FABRICATION, AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS". 4.7.3. STRUCTURAL STEEL: ASTM A36/36M 05. 4.7.4. STEEL TUBING: ASTM A500, GRADE B. 4.7.5. WELDED CONNECTIONS: E70XX ELECTRODES, MINIMUM SIZE FILLET WELDS 3/16", AWS CERTIFIED WELDERS. CERTIFICATION PAPERS TO BE SUBMITTED UPON REQUEST. 4.7.6. WHERE STEEL BEAMS ARE CONTINUOUS OVER COLUMNS, PROVIDE WEB STIFFENER PLATES ON EACH SIDE OF THE WEB, OF A THICKNESS EQUAL TO BEAM FLANGE THICKNESS, LOCATED AT THE CENTER LINE OF THE TUBE COLUMN. 4.7.7. THE STEEL FRAME IS "NON -SELF SUPPORTING". ADEQUATE TEMPORARY SUPPORT SHALL BE PROVIDED BY THE CONTRACTOR UNTIL REQUIRED CONNECTIONS OR 4.8. SOIL. ELEMENTS ARE IN PLACE. 4.8.1. MINIMUM SOIL BEARING PRESSURE CAPACITY OF 2,000 PSF. FOUNDATIONS HAVE BEEN DESIGNED WITH THE MIN. CAPACITY OF 2,000 PSF 4.8.2. ALL SOIL IS TO BE CLEAN & POISONED FOR TERMITES PER FLORIDA BUILDING CODE 7TH EDITION (2020) RESIDENTIAL SECTION R318. 4.8.3. SOIL IS TO BE COMPACTED TO 95% MODIFIED PROCTOR AS DEFINED BY ASTM D 1557-02EO1 TERMITE PROTECTION CONTRACTOR TO USE (1) OF THE TREATMENTS BELOW Borate / Boracore treated lumber Soil Chemical Barrier Method Other treatment - Must specify proposed method and submit documentation, which substantiates the proposed method, is an approved termite protection system or method. OR CHEMICAL SOIL TERMITE TREATMENT IS USED 1 FBC-R R318.1 - "A permanent sign which identifies the termite treatment provider and need for re -inspection and treatment contract renewal shall,be provid&d. The sign. shall be posted near the water heater or electric panel' 2. Condensate and roof downspouts shall discharge at least V-1)" away from the building side walls. 3. Irrigation/s grinkler systems includin aall risers and spray hea s shall not be installed wi hin V-0" of the building side wall. 4. FBC-R R318.7- To provide for inspection for termite infestation, between wall covering and final earth grade shall not be less than 6 inches. Exception: Paint or decorative cementitious finish less than 5/8" thick adhered directly to the foundation wall. 5. FBC-R R318.1.1 - Initial treatment shall be done after all excavation and backfill is complete. 6. FBC-R R318.1.2 - Soil disturbed after the initial treatment shall be retreated including spaces boxed or formed. 7. FBC-R R318.1.3 - Boxed areas in concrete floors for subsequent installation of traps, etc., shall be made with permanent metal or plastic forms. Permanent forms must be of a size and depth that will eliminate the disturbance of soil after the initial treatment. 8. FBC-R R318.1.4 - Minimum 6 mil vapor retarder must be installed to protect against rainfall dilution. If rainfall occurs befdre vapor retarder placement, retreatment is required. 9. FBC-Rb:3lm8bl a �ej �joncrete ov.erpg and mortar along the foundation perimeter must r re exterior sol treatment. 10. FBC-R R318.1.6 - Soil treatment must be applied under all exterior concrete or grade within V-0" of the structure sidewalls. 11. FBC-R R318.1.6 - An exterior vertical chemical barrier must be installed after construction is complete, including landscaping and irrigation. Any soil disturbed after the vertical barder is applied, shall be retreated, 12. FBC-R R318.1 - All buildings are required to have pre -construction treatment. 13. FBC-R R318.1 - A certificate of compliance must be issued to the building department b licensed pest control company before a certificate of occupancy willbe issued. TUcertificate of compliance shall state: "The building has received a complete treatment for the prevention of subterranean termites. The treatment is in accordance with the rules and laws of the Florida Department of Agriculture and Consumer Services". 14. FBC-R R318.6 - After all work is completed, loose wood and fill must be removed from below and within V-10" of the building, This includes all grade stakes, tub trap boxes, forms, shoring or other cellulose containing material. BUILDING DATA WIND SPEED (ULTIMATE) 140 MPH WIND SPEED (ALLOWABLE) 108 MPH WIND EXPOSURE -- "C" FBC-R 7TH EDITION (2020) R301.2.1.1 INTERNAL PRESSURE COEFFICIENT= 0.18 ENCLOSED BLDG) BUILDING CATEGORY = 11 DESIGN WIND PRESSURE: (COMPONENT AND CLADDING) WORSTICASE (10 SF - END ZONE) # END ZONE IS ONLY WITHIN 4'-0" OF ALL EXTERIOR BUILDING CORNERS WINDOWS AND DOORS CONSTRUCTION 140 MPH + 29.7 PSF / -32.2 PSF (INTERIOR) U.N.O.. TYPE: 5B + 29.7 PSF / -39.7 PSF (END) U.N.0 GARAGE DOORS (V = 140 MPH) SINGLE 90 +26.1 PSF / -29.9 PSF DOUBLE 160 +24.9 PSF / -28.0 PSF SOFFIT +29.7 PSF / -39.7 PSF NOTE: THE WIND PRESSURES LISTED ABOVE ARE ALLOWABLE PRESSURES. NOTE: IT IS THE CONTRACTORS RESPONSIBILITY TO REVIEW ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. FLORIDA DESIGN SOLUTIONS, INC. IS RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF THIS PROJECT ONLY. ANY DISCREPANCY BETWEEN FIELD CONDITIONS, OTHER DESIGN PROFESS IONALS'SHOP DRAWINGS, CONTRACTORS' BUILDING METHODS, AND THESE SIGNED AND SEALED DRAWINGS MUST BE BROUGHT TO THE ATTENTION OF FLORIDA DESIGN SOLUTIONS, INC. PRIOR TO THE COMMENCEMENT OF CONSTRUCTION. NOTE: GYPSUM BOARD MAY BE INSTALLED USING GWB54 NAILS TO SET IN PLACE. FIELD FASTENING SHOULD BE TYPE "W" 1Y4" DRYWALL SCREWS AT 12" O.C. FOR CEILINGS AND DRYWALL SCREWS AT 12" O.C. FOR WALLS. ALL ENDS AND EDGES OF WALLBOARD SHALL OCCUR OVER AND BE SCREWED TO SUPPORTS. MAXIMUM SCREW SPACING AT ENDS (EDGES IN VERTICAL APPLICATION) SHALL BE 6" O.C. AT EACH SUPPORT. MINIMUM SCREW NAIL DISTANCE FROM EDGE SHALL BE 3/8". THIS SHALL APPLY TO BOTH CEILING AND WALL INSTALLATION. DRYWALL SHIMS SHALL BE USED ONLY WHERE NECESSARY. OPENINGS CUT FOR OUTLETS, SWITCHES, ETC, SHALL BE OF A TOLERANCE THAT CAN BE COVERED ADEQUATELY WITH NORMAL SWITCH PLATES AND COVERS WITHOUT ADDITIONAL TAPING OR CAULKING. DRYWALL SHALL NOT BE INSTALLED WITHOUT PROPER BACKING. NOTE: ALL HEADERS, BEAMS, ETC ARE TO BE SYP #2 OR BETTER AND OR MICROLAM AS INDICATED ON THE DRAWINGS AND CAN NOT BE REVISED. IF C14 -�4 �NF J, P Z, To the best of the Engineer's knowledge, information and belief, the structural plans and specifications contained within these drawings comply with the 2020 Florida Building Code - Residential 7th Edition. Engineers signature and seal is only for the structural engineering portions of the drawing pages bearing Engineers signature and seal. CD W -V E cy) 8 Co r- N S, 0 0 2 u; Lu t- P-� CN 0 co U- Uj (L LL LL W z X 0 r_ Co 0 W W 0 rj) c� ca -J M L0 z 0: Ln 0 CN < b C) < z W 13 r-1 El 0 OC> IR 110 CIO 7T_ 13 V) 21- M 0 -25 Cn E u '0 _0 2 0 CAD z z z < LL- ce E CL 0 z , ZO 0� E U z 0 w CD < , U C) 0 < X C:) C-4 ro t 0 < z 0 . z n' z '0 CZ 0 01 Z z Q) z 0, 0 W < z C:) CD C.0 0 0 C:) 0 cc 0 00 0 0 > (3) oo---� > 0 0 0 C M C 0 E co C:) Lo M N -r-- LO 00 01) -- LO T- 7 00 C14 0") E CY) 0 M z E 10 M E 44 0 0 'D JOB NO: 21-2029 SCALE : AS NOTED_ SHEET NO. S N Backer and Filler Block Dimensions BCIOJoist Backer Block Thickness Filler Block Thickness Series 3/4" or 7/8" 5000s 1.8/1.7 wood panels Two 3/4" wood panels or 2 x 1-1/8" or two 1/2" 6000s 1.8/1.7 wood panels 2 x + 5/8" or 3/4" wood panel 1-1/8" or two 1/2" 6500s 1.8/1.7 wood panels 2 x + 5/8" or 3/4" wood panel 1-1 /8" or two 1/2" 602.0 wood panels 2 x + 5/8" or 3/4" wood panel 2 x — lumber Double 2 x — lumber 1 1 DOUBLE JOIST CONSTRUCTION (Not required if both loaded equally from above) Filler blocking 1/8" gap 1) Support back of web during nailing to prevent damage to web -flange connection. 2) Block solid between joists for full length of span. 3) Leave 1/8" gap between top of filler blocking and bottom of top flange. 4) Place joists together and nail from each side with 2 rows of 10d nails 2x CONTRACTOR TO PROVIDE 2x TO FILL THE HEIGHT at 12" o.c., clinched when possible. Stagger rows from opposite OF THE JOIST ASA REQUIRED LEAVING Y8" GAP @ TOP sides by 6". DOUBLE JOIST CONNECTION N.T.S. SQUASH BLOCKS AT INTERIOR BEARING Vertical load transfer =1900 plf max along load bearing wall, Load bearing wall must stack over squash=20 blocks and *Non -stacking walls wall or beam below.* require additional consideration. Check local building 116" code for appropriate details in One 1 Od box areas=20 of high or= 0 sinker 101 lateral load. nail each side -011 at bearing. TANK -LESS W/H 0, w 10 0" TANK -LESS W/H CORNER OF HOME H C G GARAGE SIDE 0 0 0 U) 5'41 0 - I STUB -OUT FOR 1 I -Off op 0 I LO GAS METER 0 f- 0 MEASUREMENTS ARE FROM FINISHED FLOOR ROUGH -IN GAS TO RIGHT (ALWAYS) - 12" OFF -CENTER ROUGH -IN ELECTRIC TO LEFT (ALWAYS) 12" OFF -CENTER GAS CONNECTION DETAIL "ONLY APPLIES TO HILLSBOROUGH AND PASCO COUNTY" RAFTER SPAN TABLE MEMBER SIZE AND SPACING MAXIMUM LENGTH MEMBER CONNECTIONS* 2" X 4" @ 16" O.C. T-5" (2) 16d TOENAILS 2" X 6" @ 16" O.C. 10'-8" (2) 16d TOENAILS 2- X 8" @ 16" O.C. 13'-9" (3) 16d TOENAILS 2" X 10" @ 16" O.C. 16-5" (1) SIMPSON HTS20 OR (3) 16d TOENAILS 2" X 12" @ 16" O.C. 191-31, (1) SIMPSON HTS20 OR (4) 16d TOENAILS 2" X 4" @ 24" O.C. (2) 16d TOENAILS 2" X 6" @ 24" O.C. 8'-6" (2) 16d TOENAILS 2" X 8" @ 24" O.C. (2) 16d TOENAILS 2" X 10" @ 24" O.C. 13'-0" (3) 16d TOENAILS 2" X 12" @ 24" O.C. 164" (1) SIMPSON HTS20 OR (3) 16d TOENAILS TOENAIL CONNECTIONS DESIGNED FOR SHEAR ONLY (i.e. RAFTER TO RIDGEBEAM). SOUTHERN YELLOW PINE, 55 PSF LOADING Boise Joist Blocking Use 3" (1 Od) nails at 6" o.c. L ad bearing walls I ii FILL CELL STD. 900 HOOK F BOND BEAM U.1 CONT. #5 > STD. 900t� 7, CONT. #5 HOOK BAR BAR #5 CONT. FROM FOUNDATION TO HIGHEST BOND BEAM BOND BEAM STEP SCALE: N.T.S. 2nd FLOOR —PLAN INTERIOR/EXT WALL SEE FOR MORE INFO CONT, BASE PLATE BEARING COLUMN PLYWOOD FLOOR SEE PLAN FOR REQ'D COLUMN AND SHEATHING PER PLAN CONNECTION TJI TO BE CUT TO ALLOW FOR BLOCKING/TJI -'—MASONRY WALL OR INTERIOR BRG. WALL TJI PER PLAN OTHERWISE SOLID BLOCKING TO MATCH # OF 2nd FLOOR Solid block all posts from STUDS above to bearing below. SECTION @ INT. BRG. WALL N.T.S. 1/8" min. }Small,gap 2"min. 2" max. 4" max. Web Stiffener Fastener Scheduile Joist Bearing Location - . I Series Depth End Intermediate 9-1/21, 2-8d 2-8d 7 1 7/- BCI 5000e, 11 -7/8" 2-8d 3-8d 14" 2_-8d____6-8d i Clinch nails 2-8d 2-8d i when possible I BCI 6000sf� 11-7/81, 2-8d 3-8d 2-8d 5-8d BCI 6500s6 10 16" 2-8d 6-8d 11-7/811 2-8d 3-8d 7 5-8�d BCI 60s8 Tight fit 16" 2-8d 6-8d 111-7/8" 3-16d 3-16d 2x4/Plywood/OSB web stiffener 2" min. 13CI 90se 14" 5-16d:E 4" max. 16" 6-16d 6-16d required when indicated or - Hangers with side nailing. - Hangers with sides not containing top flange of joist. WEB STIFFENER - Birdsmouth cuts. N.T.S. - Under 2nd floor column w/ loads higher than 15001b. BLOCKING PANEL, INTERIOR Vertical load transfer =1900 pif max. along bearing wall Required on interior walls : - for vertical load transfer when load bearing - for lateral support when joists meet over wall, or wall stacks directly over wall or beam below Load bearing wall must stack over blocking and wall or beam below.* Q� Provide adequate bearing for each lapped joist. Use 1 Odx3" nails at 6"o.c. for all joist blocking panel *Non -stacking walls Squash block Od nails quire additional consideration. (2x4 minimum) SECTION @ INT. BRG. WALL re N.T.S. Bearing wall, Versa -Lam LVL or Glulam Beam 7L,,LVL or ItAK, 0, NO HOLES (EXCEPT MINIMUM SPACING 2x GREATEST KNOCKOUTS) ALLOWED DIMENSION OF LARGEST HOLE IN BEARING ZONES D (KNOCKOUT EXEMPTS) (see table below) D LO (see table below) 'see \CT_ DO NOT cut, notch or drill flanges rl 6"^ A 1Y2" ROUND HOLE MAY BE CUT ANYWHERE IN THE WEB. PROVIDE AT CANTILEVER LEAST 3" OF CLEARANCE FROM OTHER HOLES MINIMUM DISTANCE FROM SUPPORT, LISTED BELOW, IS REQUIRED FOR ALL HOLED GREATER THAN ly2,. DO NOT CUT HOLES LARGER THAN ROUND IN CANTILEVERS. Any 16' joist Span (R) 8 T-9' I T-I " 11'-Z' 11 �-2" 1 11-3' T-3r' 1 V-7' T-111"I 2-4" 2-9' 1 3-2' 3-7' 12 T-O" T-11" T-2' V-2" T-3' T-9' 2-4' Z-111" 3-7- 41-Z' 4'-9' 6-41 16 l'-C' T-11" I'-Z' '-2" V-7 2-6' 3-2' 3-10" 4-9' 6-7- 6-4" 7-2- 20 I'A I'-Z' �1'-2" 2I-U' #�l 3-9' 4-a' 4-10" 6-11" 6-111" 7�111" 8'-111"� 24 "� . I -a' I , ". T-I I'-Z' I V-3" 7-6' 3-7' 4-9' 9-10" 7-7' 8-4" 9-6' - 10'-91 NOTES: 1. JOISTS MUST BE PROPERLY DESIGNED TO MEET BUILDING CODE REQUIREMENTS. 2. TABLE IS FOR UNIFORMLY LOADED MAXIMUM LOADS OF 40 PSL(LIVE) AND 15 PSF (DEAD) ON SIMPLE SPAN APPLICATIONS ONLY. 3. REFER TO JOIST SPECIFIER GUIDE FOR INSTALLATION AND OTHER INFO. 4. SELECT A TABLE ROW BASED ON JOIST DEPTH AND THE ACTUAL JOIST SPAN ROUNDED UP TO THE NEAREST TABLE SPAN. SCAN ACROSS THE ROW TO THE COLUMN HEADED BY THE APPROPRIATE ROUND HOLE DIAMETER OR RECTANGULAR HOLE SIDE. USE THE LONGEST SIDE OF A RECTANGULAR HOLE. THE TABLE VALUES IS THE CLOSEST THAT THE CENTERLINE OF THE NEAREST SUPPORT. 5. THE ENTIRE WEB MAY BE CUT OUT. DO NOT CUT THE FLANGES. HOLES APPLY TO EITHER SINGLE OR MULTIPLE JOISTS IN REPETITIVE MEMBER CONDITIONS. 6. FOR MULTIPLE HOLES, THE AMOUNT OF UNCUT WEB BETWEEN HOLES MUST EQUAL AT LEAST TWICE THE DIAMETER (OR LONGEST SIDE) OF THE LARGEST HOLE. 7. %" ROUND KNOCKOUTS IN THE WEB MAY BE REMOVED BY USING A SHORT PIECE OF METAL PIPE AND HAMMER. 2' 8. HOLES MAY BE POSITIONED VERTICALLY ANYWHERE IN THE WEB. THE JOIST MAY BE SET WITH THE 1Y - KNOCKOUT HOLES TURNED WITHER UP OR DOWN. 9. THIS TABLE WAS DESIGNED TO APPLY TO THE DESIGN TO APPLY TO THE DESIGN CONDITIONS COVERED BY TABLES ELSEWHERE IN HIS PUBLICATION. USE THE BC CALC SOFTWARE TO CHECK OTHER HOLE SIZES OR HOLES UNDER OTHER DESIGN CONDITIONS. IT MAY BE POSSIBLE TO EXCEED THE LIMITATIONS OF THIS TABLE BY ANALYZING A SPECIFIC APPLICATION WITH THE BC CALC SOFTWARE. HOLE CUTTING CHART N.T.S. When joists meet over wall, provide 13/4" minimum bearing for each. SIMPSC w/ (22) � NAILS 1 5/81 THRU BOLT SIMPS( w/ (22) � NAILS 1 R TRUSS 'OP PLATE J.0 TYPICAL SIMPSON MGT TO BUILT-UP COLUMN DETAIL TYPICAL SIMPSON LUS/HUS/HUC INSTALLATION MIN. EMBEDMENT SCHEDULE FOR AND QUANTITY )F FASTENERS TYPICAL SIMPSON META1 2 Plumbing META12 TSS INSTALLATION Joist I -Joist can be offset up to 3" to avoid vertical plumbing 3" max JOISTS OFFSET N.T.S Backer block (12" wide min.) Nail with 10- 1 Od nails. -,.Install tight to. top flange. Joist hanger Filler block. Nail with 10-10d nails. Backer block required where top mount hanger load exceeds 250 lbs. Install tight to top flange. 1/4"-2" gap ------------------------ __ - ____ Backer Block " "Top Mount" "Face Mount" Backer block shall be tight Backer block shall be tight to bottom of top flange with to top of bottom flange with 1/4"-2" gap at top of bottom 1/4"-2" gap at bottom of top flange. flange. eb stiffner as Web stiffeners are not required when top required if hanger flange is laterally supported by joist hanger. doesn't meet height _'J requirements 1 .0 6 X Joist T X c depth � L LOX .1-JOISTS BUCKETS N.T.S. A/C CHASE 4" PVC SLEEVE THRU STEM WALL SLEEVE THRU STEM-/ SEE PLAN FOR--" FOUNDATION INFO .!t 4' STEM FOUNDATION GRADE REINF. SEE PLAN i-vt, uni-xot,+ rvL, SLEEVE THRU FOOTING MONO FOUNDATION TYP. FND. PENETRATIONS SCALE: N.T.S. SIMPSON META12 META12 TSS INSTALLATION @ MID SPAN NOTE: UPLIFT VALUE IS BASED ON S.P.F. LOCATION OF SECOND H10A SIMPSON H10A 0 (WHEN REQUIRED) w/ (118) 1 Od x 11/2" NAILS UPLIFT= 1015# 10 1 /2' x 10151 TYPICAL SIMPSON H10A INSTALLATION TYPICAL SIMPSON MTS HTS INSTALLATION TOP (2) #5's x 4' 0" CENTERED @ PI�E� PENETRATION 12" BELOW GRADE PLUMBING LINE PVC OR SCH40 SLEEVE A. 4 SEE FND. PLN. SIZE & REINF. PIPE VERTICAL THRU FND. PENETRATION TOP (2) #5's 4'-0" CENTERED @ PIPE A PLUMBING LINE PVC OR SCH40 SLEEVE A ./e, 4'A A ;2� 0 4. 0 A A SEE FND. PLN. SIZ E & RE PIPE PERPENDICULAR TO FND. TOP (2) #5's x 4'-0" CENTERED @ PIPE PENETRATION A q A SEE FND. PLN. SIZE & REINF. PVC OR SCH40 SLEEVE PLUMBING LINE Aq. A . A' .4 C14 C=31 C14 C=0 'I.,, -.1% i_EWKO !" . *r-. - z 0 - 7b75 'D . % S-�Pl 1�1 1, -P �<) '. e To the best of the Engineers knowledge, information and belief, the structural plans and specifications contained within these drawings comply with the 2020 Florda Building Code Residential 7th Edition. Engineers signature and seal is only for the structural engineering portions of the drawing pages bearing Engineers signature and seal. W ot E co 8 U R 0 -9-.- 0) 0 rZ _01 Lu - (N C) CL M LL U_ (L w 0 z 0 I - CD M Co N _J ILI ILI 0 2 co 05 C� <e z LL co Z� Ci IL X 0 0 < 00 z 11:,� W F El I Cl) C) < 0 -2 U- C/_J LU 0 U0 Ln :::D fz U) E A 0 C.0 C13 z U_ E 14 E oy Z I-T E 04 o 0 00 0� 0< � .0 :9t =3 co 2 0, Z, Cn < 0, M z -� 0 CL 2< � 20 Z < CD C.0 0 .< 0 2 > 0 0 L_ t: 00 0 "94- < 3i > 0 C) 0- 0 (0 C 0 rl%.4 E — L_ 04 CIO C) Ln TZ 04 LO CY) LO T_ 0o (N 04 0 E C1114 co �i 0 z M z E 4D a n E 0 0 'a cc < a) JOB NO 21-2029 SCALE AS NOTED SHEE7 NO. SN 1 C" 1E C14 C=) 9 (:;n C"! C:) C'4 CD C14 C=� CN ck: C"I E E k2 CL C'4 4; (3- CD C'4 C> ROOF FLASHING AND ROOF FLASHING COMPONENTS TO BE IN ACCORDANCE w/ R903.2, FLORIDA BUILDING CODE 7TH EDITION (2020) RESIDENTIAL 12 (TYP.) VARIES I Fil 2x BLOCKING HORIZONTALLY@ 2x #2 SPF STUDS INTERVALS NOT EXCEEDING @16" O.C. W/ (2) 10'-0" (R302.1 1) 16d TOENAILS T & B v FOR UNDERLAYMENT REQUIREMENTS SEE R905.1.1 I r 1 1/2" GYP. WB (MIN.) @ GARAGE SIDE IF :;� PRE ENGINEERED WOOD APPLICABLE. TRUSS @ 24" O.C. U.N.O. 2x P.T. PLATE - 1/4" DIA X 3 1/4" TAPCONS @ 24" O/C & r_: HURRICANE ANCHOR @ EACH @ 6" MAX FROM END OF 2 x PLATE = E TRUSS (SEE UPLIFT SCHED.) W/ (2) #5 CONT. ON 3" 6 x 6 W1.4 x W1.4 METAL PL. UNDER EA. TRUSS CHAIRS (TYP.) WWF OR FIBERMESH Cl) MOISTURE BARRIER A SHINGLE ROOF, SHINGLES TO A t - BE IN ACCORDANCE w/ ASTM D7158-CLASS G or H, or ASTM D3161-CLASS F, IN ACCORDANCE w/ TABLE :AIVIL R905.2.6.1, FLORIDA BUILDING IV I -71 1 P11 III CODE 7TH EDITION (2020) 8" - RESIDENTIAL ROOF SHEATHING - SEE SCHEDULE - [RSH] - ON TYPICAL INTERIOR BEARING FRAMING SHEET FOR SHEATHING AND FASTENERS WALL w/ OUT UPLIFT ELEV. VARIESAii-"\ SEE TYP. WALL SECTION SCALE: 3/4"=V-0': 5/8" OR 1/2" HIGH-------'-- ALUMINUM DRIP STRENGTH CEILING EDGE BOARD PER CODE (OR 5/8" GYP. TYPE "X" @ GARAGE W/A HABITABLE ROOM LUMINUM FASCIA , \12' N.O. 2x SUB FASCIA ABOVE) W/DRYWALL EE STRUCTURAL SCREWS @ 7" O.C. SOFFIT SHEET SS CEILING & 8" O.C. WALLS x8"X16" KNOCK -OUT INSULATION PER BLOCK W/ 1#5 CONT. CHART ON FLOOR FILLED SOLID W/GROUT PLAN 1x2 P.T, HORIZONTAL NAILER C.M.U. TYPICAL STD. 90-HOOK (SEE DETAIL) "S" MORTAR ARCHITECTURAL ,-------FINISH 1x2 PTWD FURRING @24"O.C.-/ 1/2" GYPSUM WALLBOARD U.N.O. (1) #5 VERT. IN FILL CELLS(SEE FOUNDATION PLAN FOR LOCATIONS) 1x4 P.T. BASE NAILER 4"x4" INSPECTION 3 1/4" BASEBOARD PORT AT EACH FILLED CELL TYPICAL S MIN. 2500 PSI CONC. SLAB AT GARAGE CONTRACTOR MIN PSI MAY VARY PER PEI U) TO CUT BLOCK OR POUR MUNICIPALITY. CURB DUE TO SLOPE CONCRETE SLAB W/ 6X6 /—NOTE:EXTEND W1.4XW1.4 WW FOR DECO FINISH 4" to 6" "FIBERMESH" BELOW GRADE C14 A I, 00 Cl) 00 6 MIL VAPOR 2� BARRIER C> I> C14 COMP. SOIL. (COMPACTED TO 95% MODIFIED PROCTOR ASTM D1557) 3" MIN. CLR. (2) #5 REBAR CONT.-/ ON 3" CHAIRS TYP. 1'4" (1 STORY) STD. 90 HOOK (SEE U.N.O. 14" IV-8" (2 STORY)i DETAIL) TYPICAL WALL SECTION rA SCALE: 3/4" = V-0" Q3 OPT: DEPRESS SLAB 5 Y2" DEEP AND 6" BEYOND - LOAD BEARING OR EXTERIOR WALL SEE CC/S3 OR G/S3 FOR ANCHOR BOLTINFO. (IF NO UP LIFT ON WALL SEE GG/S3) *SIMPSON SP1 w/ (10) 10d NAILS TYP. MONO OR STEMWALL- FOOTING MONO SHOWN FOR CLARITY NOTE: *FOR BEARING WALL W/ UPLIFT ONLY GG S3 8"x8"xl 6" NOMINAL BLOCK WITH 3/8" MORTAR BETWEEN COURSES 3/8" MORTAR BETWEEN SLAB & BLOCK Cl) ELEV. U-0" ot A. F.F. ELEV. 4-3 1/2" 4 1 4 4 < 4 4 2x4 CONT�Z 1 4 A.F.F. 'o U- 04 GARAGE DEPTH VARIES 4 I I GARAGE SLAB AT STEP SCALE: 3/4"=V-0" 2x S.P.F. STU S @ 16" O.C. ,",,-2x STUD 81, C , M * U i,-x P.T. STUD #5 VERT. IN FILLED CELL 5/8"x6" "J" BOLTS BOLT @ 24" O.C. VERT. OR 5/8" x 6" EPDXY BOLT OR (6) 1/4"x3 1/4" TAPCONS SPACED EVENLY 2x P.T. PLATE ASSUMED FINISHED GRADE I r I rL m�=j 11-111-111- I �= FRAME WALL TO C.M.U. WALL CONNECTION SEE TYP. WALL SECTION FOR ADDITIONAL SCALE: 3/4"=V-0" SLAB INFORMATION. 6 x 6 W1.4 x W1.4 3 1/2" WWF OR FIBERMESH min.) 4"--, A GRADE 00 7 --I 1 11 1IILLiF - 11 11 X, Fir -_rr--7p =�. #5 REBAR w/ OPT. ... ... WISCREEN ENCLOSURE MIN. TYPICAL THICKENED SLAB EDGE SCALE: 314"=V-0" � S3 DOOR TO RECEIVE BLOCK WALL BEYOND - BLOCK WALL BEYOND PAVERS / DRIVEWAY EXPANSION JOINT I ­�, CONCRETE SLAB 14" O.H.D. RECESS "T 13" 0 H D RE CESS PAVERS� e A 4. :4" 50 OP 4 I I r SEE A/S3 OR J/S6 IT M I - SEE A/S3 OR J/S6 - FOR REINF. INFO. �3" MIN. CLEARANCE FOR REINF. INFO. 3" MIN. CLEARANCE 1'4" (1 STORY) / V-8" (1 STORY w/ DEPRESSED SLAB OPT.) V-4" (1 STORY) 1' 8- (2 STORY) V-8" (2 STORY) GARAGE DOOR SLAB RECESS GARAGE DOOR SLAB RECESS rT� SEE TYP. WALL SECTION FOR SCALE: N.T.S. SEE TYP. WALL SECTION FOR SCALE: N.T.S. �3 ADDITIONAL INFORMATION. ADDITIONAL INFORMATION. 1/2" OR 7/16" OSB MIN. PLYWOOD SHEATHING - NAILED W/ 8d COMMON NAILS @ 4" O/C BOUNDARIES, 6" O/C EDGES, AND 12" O/C FIELD. SHEAR WALL REQUIRES 2x BLOCKING @ SEAMS. 2x BLOCKING HORIZONTALLY@ INTERVALS NOT EXCEEDING 10'-0" (R302.1 1) 5/8"' x 10" "J" BOLT @ 24" OIC W/ 2"'X 3/16" PLATE WASHER TYPICAL MIN. 2500 PSI CONCRETE SLAB W/ 6 x 6 W1.4 x W1.4 WWF OR FIBERMESH E L =L r ffr 6 MIL VAPOR BARRIEFAM 2x STUDS @ 16" O/C 0� INSULATION PER FBC AND ENERGY FORM SUBMITTED WITH PERMIT APPLICATION 7/8" STUCCO FINISH PER ASTM C. 926 APPLY 3 LAYERS W/ TOTAL THICKNESS 7/8" OVER METAL LATH. FIRST 2 LAYERS 3/8" THICK EACH. CONTINUOUS TO FOOTER BELOW 90 HOOK DETAIL 3RD LAYER 1/8" THICK. @ K.O. BLOCK SIMPSON SP1 w/ (10) 10d NAILS @ EA. STUD 2X PT PLATE 20- MIN. LAP [24- MIN. LAP) #5 REINFORCING WEEP SCREED INSTALLED BAR PER MFR INSTRUCTIONS #3 OR -HA REINFORCING BAR ;i #3 & #4 LAP SPLICE GRADE 40 MIN. Fy= 40ksi FINISH GRADE 60 M L 25" MIN. LAP [30- MIN. LAP] [GRADE 6 7v= 60ksil 0? I �1 1- ;M77 ­14 1 s 11 - I #5 REINFORCING BAR R 17/8" #5 LAP SPLICE 36" MIN LAP 26" MIN LAP' COMP. SOIL. (COMPACTED TO A zzz==� 95% MODIFIED PROCTOR ASTM 101, D1557) . . - I - - - d,�xx­xxy ­X� ­­ XXX/,X -1- �xx/' 4" V-4" -'--#6 REINFORCING BAR #5 STD. 90 HOOK #6 LAP SPLICE TYPICAL EXTERIOR FRAME WALL FOOTING SEE TYP. WALL SECTION FOR ADDITIONAL SCALE: 3/4"=V-10" SLAB INFORMATION. 1/2" GYP. BD. P.T. 2x HOLD GYP. BD. 1/2" FROM SLAB CONT. BEAD SEALA� A, < INTERIOR 4. -3 1/2" CONCRETE NAILS W 1 1/2" EMBEDMENT @ 12" O.C. STAGGERED, FROM BOTTOM PLATE TO CONCRETE (MIN. SHEAR 180# MIN. TENSION 120#) CONCRETE SLAB----, 4— C? Cl) 6 MIL VAPO BARRIER 14" 14" INTERIOR WALL SLAB STEP NON-BRG SCALE: 3/4"=1'-0" -2X STUDS @ 24" O.C. U.N.O. GARAGE 1/2" GYPSUM WALLBOARD U. N.O. W/ DRYWALL SCREWS @ 8"O.C. -INSULATION PER CHART ON FLOOR PLAN CONT. BEAD SEALANT 6 x 6 W1.4 x W1.4 �WWF OR FIBERMESH Cl) K S3 REBAR DETAILS F SCALE: N.T.S. 1\.�3� SEE PLAN FRAME -DOWN FALSE BEAM w/ (3) 10d NAILS TO TRUSS TOP CHORD AT 24" O.C. MAX SEE PLAN FOR /-6, TOP OF BEAM (2) HTS20 SEE DETAIL 16/D1 FOR COLUMN TO PORCH SILL ATTACHMENTS & 18/D1 FOR COLUMN TO BEAM ATTACHMENTS U) � ZL) LLJ LU LU Uj V) NOTE: SEE SECTION C/S3 FOR ADDITIONAL INFORMATION SIMPSON SP1 w/ (10) "' " v' 10d NAILS 2x P.T. PLATE SPACE ANCHOR BOLTS 6" MAX FROM I AT END OF 2"x PLATE A U) CL LU 1-yar LLJ (n SEE ROOF PLAN FOR TRUSS CONNECTION INFO & LAYOUT DESIGN SEE ROOF PLAN =00 FOR STRUCTURAL BEAM SIZE & CONNECTION INFO 2x4 #2 SYP P.T. FRAMING w/ MIN 7/16" O.S.B. SHEATHING ATTACHED PER NAILING SCHEDULE SEE PLAN FOR STRUCTURAL COLUMN SIZE AND BASE CONNECTION INFO. SECURE 2x4 P.T. BTM. PLATE w/ 1/4"x3" TAPCONS AT 8" O.C. TRIM PER PLAN SQUARE CMU BLOCK BASE, SIZE VARIES PER PLAN w/ MIN. (2) #5 VERTICALS FILLED SOLID (SEE PLAN FOR SIZE AND REINFORCEMENT) BRICK PAVERS or SLAB PER COMMUNITY SPECS ---------- A SCALE: 3/4— V-0" (2) #5 CONT.-- ON 3"CHAIRS (TYP.) 8" V-4" 2x BLOCKING HORIZONTALLY@ INTERVALS NOT EXCEEDING 10'-0" (R302.1 1) 1/2' GYP. WB (MIN.) @ GARAGE SIDE IF APPLICABLE. 5/8"DIA. EXPANSION BOLT @24 O.C. W/ 7" EMBEDMENT (MIN. SHEAR 3500#, MIN. TENSION 2600#) 6 x 6 W1.4 x W1.4 WWF OR FIBERMESH co 8" TYPICAL INTERIOR BEARING WALL w/ UPLIFT G� SCALE: 3/4"=V-0" ���3 1 1/2" RECESS FOR VARIES 6 x 6 W1.4 x W1.4 S.G.D. (U.N.O.) F WWF OR FIBERMESH SEE A/S3/J/S6 -` 1 8" FOR REINF. INFO. OPTION #1 SEE TYP. WALL SECTION FOR ADDITIONAL SLAB INFORMATION. SLAB STEP & RECESS (@ S.G.D. //M SCALE: 3/4"=1'-0" \, S3 MASONRY WALL AND PAD FOOTING 8" MASONRY WALL EXTEND FILL CELLS TO FOUNDATION PAD CONT. FOOTING STEEL MAT REINFORCING. !Z�! Cl) z 00 GRADE 43 0 LU 5, = =-, LU LU LU 0 LLJ C/5 FT z 00 0 Cr (n C01 LL UJI I IF I E71 I I -I I 1=1 1 1 I= I I =1 I 1=I I �-11 FOOTING d I =--I I =1 I 1--I I - BEYOND PAD REINFORCEMENT-1 , 1-11 1=1 I =1 I I , 3" MIN. CLEARANCE (SEE SCHEDULE) FOOTING WIDTH SEE SCHEDULE PATIO COLUMN FTG. DETAIL (N SCALE: N.T.S. 1\ �3 *S -0� 7 LUZ O� .x To the best of the Engineer's knowledge, information and belief, the structural plans and specifications contained within these drawings comply with the 2020 Flodda Building Code - Residential 7th Edition. Engineers signature and seal is only for the structur I engineering po ons o e rawngpages eanng Engineer's signature and seal. W Go V- E 0 co CD 04 V -j C., 0 (D 6 :� , 5 'CO It- LU co - U, C, LL. s CC LL a. 0 0 E :3 Z 64 (0 LL -J W W 0 2 - ;; 03 -mj (n T < o z IL 6 fL r- 00 Z� C', L/) 0 < 0 C-) W < V) CD 4—J 0 5 di E U) < 00 0 r— LL- cd E 0 �z 0 ZR < Ka U cu 0 �, & 00 CL ,­ E => ru 0 T 8 '< . 0, z -z CN t 0 ru < z< �0 1, 0 z IC-5 U:) __j .0 , �z <� 0) 0 1 0 1z 0 CX �u z 0 �z 5 CD Cn C:) 00 0 > 0 0 E 16- CU C) 0) LO CY) LO T 00 CN E CY) 0 M z E cc E 0 0 0 —j JOB NO: 21-2029 SCALE : AS NOTED SHEEr NO. S3 (MONO) W T3 C�- co C14 :0� C'4 CD C , ' 1 4 :1� E3 z 0 1: Of 00 8 C'4 to CD 5�_ 9 0 CL E �2 E Cn E 20 0_ C) Z::Z- C*4 C) (2) 2x6 OR (2) 2x8 TOP PLATE SEE VENT OR 2ND FLOOR PLAN 1/2" MINIMUM CEMENT FINISH �/--TYPICAL C.M.U. WALL 2x6 / 2x8 WALL BEYOND (2) 2x HEADER TO SIT FLUSH TO THE OUTSIDE STANDARD 3" DIA. TEE 3/4" FURRING STRIPS SEE PLAN FOR HEADER SEE PLAN FOR SIZE THREADED 3" DIA. EXTENSION 1/2" GYPSUM BOARD CONNECTION SCREW OFF CAP (3" DIA.) W/ DRYWALL SCREWS 2x DEAD WOOD @ MID FOR CLEAN -OUT @ 8" O.C. OR 4d PO I NT w/ (3) 12d DRYWALL NAILS MIN. EXTENSION FROM DOUBLE 2x TOP TONEAILS SPACED EVENLY EXTERIOR FACE OF BLOCK 11/2" MAXIMUM PLATE 7 INTERIOR HEADER FLUSH TO OUTSIDE OPTION EXTENSION FROM EXTERIOR WALL FACE OF BLOCK WALL IS 2 1/4" vARIE5 2x BLOCKING @ EACH END W/ 1 Od @ 4" O.C. FROM EACH HEADER FACE TO BLOCKING _(2) 2x HEADER PER PLAN 2x BOTTOM PLATE W/ (1) 1 Od @ 8" O.C. TO EACH HEADER FACE 2 x 6 (MIN.) FRAME WALL HEADER DETAIL SCALE: N.T.S. �4 12 SEE TYPICAL WALL SECTION ,,----.-_—PRE-ENGINEERED WOOD SEE ELEV. TRUSSES @ 24" O/C UPLIFT CONNECTOR (SEE SCHEDULE) DOUBLE 2x4 SPF. #2 TOP PLATE 2x S.P.F. STUDS @ 16" O.C. SINGLE 2x CONT. TOP PLATE W/ (2) 12d INTO TRUSS ABOVE 2x CLOSURE WALL W/ STUDS @ 16" O.C. W/ SIMPSON SP2 W/ (12) 10d (3) 1 Od TOENAILS T&B NAILS AT EACH STUD AS REQ'D 2x BLOCKING @ MID POINT EVERY OTHER + + STUD W/ (3) 1 Od NAILS CRICKET AS REQUIRED SINGLE 2x CONT. BASE PLATE W/ (2) 16d TO TRUSS BELOW 1/2" EXTERIOR GRADE SHEATHING FASTENED TO TRUSSES WITH 8d COMMON WIRE NAILS (@ 4- O/C BOUNDARIES 6" O/C EDGES & 8" O/C FIELD v SIMPSON SP1 W/ (10) 10d NAILS AT EACH STUD 2x P.T. PLATE 5/8" x 10" "J" BOLT @ 24" O/C MAX W W/ 8" EMBEDMENT 8"X8"X16" K.O. BLOCK W/ 1 #5 CONT. AND FILLED SOLID W/GROUT 1 #5 VERT. IN CONC. FILLED CELL W/ 90A STD. HOOK IN K.O. BLOCK KNEE WALL ABOVE MASONRY WALL DETAIL MOUNTING BASE NOT SHOWN FOR CLARITY SEE DETAIL K/S4 SEAT FOR BLOCK IS POURED, IN PLACE CONCRETE GARAGE FLOOR SLAB TROWEL FINISH SEE GENERALNOTES SLOPE FORWARD FOR DRAINAGE BLOCKING (TYP.) TRUSS UPLIFT CONNECTOR (SEE SCHEDULE) MOISTURE BARRIER SCALE: N.T.S. SEE PLAN FOR FOOTING DIMENSIONS GARAGE ENTRY FINISHED MASONRY DETAIL SCALE: N.T.S. CL TO DRAIN EXTERIOR WALL WALL CLEAN -OUT A� SCALE: N.T.S. 1STCOURSE 2ND COURSE 3RD COURSE MASON TO LAY BLOCK AS SHOWN ABOVE. EVERY COURSE MUST BE BONDED TO THE REFER TO WINDOW PRODUCT APPROVAL COURSE BELOW. EVERY THIRD (3RD) COURSE THE 11" DOOR JAMB WALL IS TO BE SHEETS FOR INSTALLATION INFORMATION BY WOVEN INTO THE MAIN FRONT TO REAR WALL AS SHOWN. MANUFACTURER. TYPICAL SECTION THRU WINDOW (BN� MASONRYLAYOUT rD SCALE: N.T.S. 7 518" 8" 7 5/81, 8" 7 5/8" 8" KNOCK -OUT — NOTCH LINTEL WHERE REQUIRED BLOCK W/ (1) #5 FOR CONCRETE PLACEMENT 7 11 7� 11 47-- ­ 1 11 ii 4 4 4 1 4 STD. WHOOK LINTEL BEAM W/ (1) #5 CONT. IN OPENINGS GREATER THAN 6'-0" WIDE (U.N.O. ON PLAN) OPENING FILLED CELL W/ (1) #5 VERTICAL '1� SEE FDN. PLAN FOR LOCATION - - T NOTES: FILL LINTEL AND ALL CELLS ABOVE LINTEL. NOTE: FOR BEAM DEPTH 22", PROVIDE A 4"x 4" INSPECTION PORT @ EACH VERTICAL REBAR & DIRECTLY ABOVE THE LINTEL. VERIFY THAT ALL REINFORCEMENT HAS BEEN PLACED PROPERLY. SEE FLOOR PLAN FOR ADDITIONAL INFORMATION. @ OPENINGS LESS THAN OR EQUAL TO 6'-0" IN WIDTH DO NOT REQUIRE ADDITIONAL STEEL REINFORCEMENT UNLESS NOTED ON FLOOR PLAN. TYPICAL FILLED LINTEL ASSEMBLY SCALE: N.T.S. WIDTH OF OPENING VARIES 4" FORM CONCRETE INSET TO CREATE A SOLID BASE FOR 1/2"X9 1/2" PLYWOOD BLOCK WALL ABOVE. ERIAL AT SCRAP M MOUNTING BASE SHOWN IN POSITION -2x6 MOUNTING BASE < LU > 0 FORM CREATES CONCRETE RECESS TO 2X4 (NOM.) RECEIVE GARAGE DOOR AND TO ALLOW FOR WATER SHED. KEEP STIFFENER BACK FROM SIDES ENOUGH TO ALLOW SPACE FOR FLAT MASONS TOOLS (THIS IS A RECOMENDATION FOR CONSTRUCTION OF THIS FORM. ANY MATERIAL OR CONSTRUCTION METHOD MAY BE USED PROVIDED END PRODUCT MEETS THE SHAPE AND DIMENSIONS OF THIS DRAWING.) GARAGE ENTRY FORM DETAIL 8x8x 16 C. M. U. GARAGE DOOR GARAGE DOOR ROLLER NN, CONNECTION ASSEMBLY GARAGEFLOOR TRAVEL DIRECTION OF GARAGE DOOR MOUNTING BASE DETAIL SCALE: N.T.S. TRACK MOUNTING BRACKET GARAGE DOOR TRACK SCALE: N.T.S. 4 4 I POURED CONCRETE BASE FOR 'BOTTOM OF MOUNTING B) TO BE 2"ABOVE FINISHED BLOCK WALL. RECESSED SPACE GARAGE FLOOR. FOR GARAGE DOOR AND WATER SHED FORWARD THIS DRAWING. PARTIAL INTERIOR ELEVATION SCALE: N.T.S. � �IAI �,o OtI, 2x CRIPPLES @ 16" O.C. W/ (2) 12d TOENAILS T/B SIMPSON SP4 W/ (6) 1 Od x 1 1/2" AT EA STUD (USE SP6 FOR 2x6 WALL, USE SP8 FOR 2x8 WALL) 10d NAILS @ 8" O/C TYP. DOUBLE 2x CRIPPLE STUD TYPICAL (U.N.0 . ) � SOLID AREAS ARE STEELANDGROUT FULL 8x8x16 BLOCK DOOR OPENING VERTICAL JAM 5/8"DIA. x 8" J-BOLTS AT 6-3/4", 41-3/4", 71 AND 96-3/8" ABOVE GARAGE FLOOR. ALL J-BOLTS WILL BE IN FILLED CELLS (2,000 PSI MIN. CONCRETE). ANCHORS MAY BE COUNTERSUNK (BUT NOT REQUIRED) TO PROVIDE A FLUSH MOUNTING SURFACE. HORIZONTAL JAMBS DO NOT TRANSFER LOAD. 2 x 6 P. J-BOLT BRACKET TRACK rop 1ARAGE iOOR W/MOUNTING ANGLE NOTE: REFER TO GARAGE DOOR PRODUCT APPROVAL SHEETS FOR DOOR INSTALLATION INFORMATION PER MANUFACTURER TYPICAL GARAGE DOOR BUCK I( �K SCALE: N.T.S. �4 HEADER SUPPORT NO. OF JACKS & STUDS REQ. AT OPENINGS OPENING 2" x 4" WALL 2" x 6" WALL STRAPS JACKS STUDS JACKS STUDS SIZE EA END EA END EA END EA END SIMPSON 11 - 4' (1) (2) (1) (2) (1)LSTA30 4'- 9' (2) (3) (2) (2) (1)LSTA30 9'-16' (3) (4) (2) (4) (2) LSTA30 FLAT TRAPS PER CHART ABOVE TO BE BENT OVER TOP PLATE ** HOLD DOWN CONNECTIONS NOT REQUIRED @ BEARING WALLS NOTED WITHOUT UPLIFT SEE FLOOR PLAN NOTES FOR REQUIRED CONNECTION 2-ROWS 12d NAILS STAGGERED @ 12" O/C EACH FACE OR 3-ROWS 12d NAILS STAGGERED @ 12" O/C FOR 2"xl 0" OR GREATER HEADER \—(2) 2x HEADER SEE PLAN * INTERIOR HEADER: \_(1) 2x SILL PLATE W/ (2) 12d TOENAILS BOX HEADER EXTERIOR HEADERS: ONLY (1) 2x SILL PLATE W/ (2) 12d TOENAILS OPENING LARGER THAN 4 FT: (2) 2x SILL PLATE w/ SIMPSON LS30 w/ (6) 1 Od x 11/2" EACH SIDE "-2x STUDS TYP. SIMPSON HTT4 TYP. U.N.O. SEE N/S4 HOLD DOWN CONNECTIONS NOT REQUIRED @ P.T. BOT. PLATE BEARING WALLS NOTED WITHOUT UPLIFT WALL HEADER DETAIL rQ SCALE: N.T.S. � �4 SIMPSON SIMPSON SP2 SP4 2X STUDS @ 24" O.C. TRANSOM FRAMING SEE SECTION AA/S1 AND BB/Sl FOR ADDITIONAL DETAILS 12 (TYP.) SEE ELEV. I SEE TYPICAL WALL SECTION PRE-ENGINEERED WOOD UPLIFT CONNECTOR (SEE SCHEDULE) DOUBLE 2"x4" S.P.F. TOP PLATE 7/8" STUCCO FINISH PER ASTM C. 926 APPLY 3 LAYERS W/ TOTAL THICKNESS 7/8" OVER METAL LATH. FIRST 2 LAYERS 3/8" THICK EACH. 3RD LAYER 1/8" THICK OVER WATER RESISTIVE BARRIEZ� SIMPSON SP2 w/ (12) 10d NAILS AT EACH STUD T RUSS BOTTOM CHORD OR 2x4 1/2" EXTERIOR GRADE SHEATHING CRICKET [BLOCKING W/ 2-16d TOE NAILS EACH END FASTENED TO TRUSSES WITH 8d D:AS:::5�� REQUIREgD�� COMMON WIRE NAILS @ 4" O/C BOUNDARIES 6"O/C EDGES & 8" BLOCKING Lu 0 O/C FIELD J 2� < CL 2x TOP PLATE R to \!2-16d 2X4 PT STUDS @ 16" O.C. NAILS @ 24" O.C. OR (2) 2X4 PT STUDS UNDER HIP EQUAL TO TRUSS BOTTOM CARRIER/GIRDER TRUSS CHORD OR BLOCKING SIMPSON HETA20 w/ (8) 1 Odxl 1/2" EB NAILS AT EA. TRUSS VERTICAL WEB 2x STUD @ 24" ENT (24" O.C. MAX) w/ MIN. 4" EMBEDMENT LMAIN O.C. MAX. PROVIDE P.A.F. NAILS OR IN KO BLOCK AT EA. STUD A I SPAN 2x P.T. PLATE EQUAL @ 12" O.C. MOISTURE BARRIER ROOFTRUSS SEE A/S3 FOR STAG GERED FROM BOT. UPLIFT CONNECTOR REINF. INFO. PLATE TO CONCRETE 8"X8"X1 6" K.O. BLOCK W/ 1 #5 CONT. (SEE SCHEDULE) AND FILLED W/ GROUT 1 #5 VERT. IN CONC. FILLED CELL------ H I W/ STD. 90' HOOK IN K.O. BLOCK -min- ALT. KNEEWALL ABOVE MASONRY WALL DETAIL SCALE: N.T.S. PIPE OR DUCT w/ PENETRATION THRU TOP PLATE w/ MORE THAN 50% OF TOP PLATE WIDTH INSTALL SIMPSON PSPN516Z w/ (12) 16d NAILS r" ��ICE �A SP TOP 2 ROWS 1 Od @ 3" O.C. (14 SPLICE NAILS TOTAL) EA. SIDE OF 4&,, SPLICE STAGGERED 1 Od @ 8" O/C ATTACH ALL EXTERIOR STUDS W/ (4) 16d TOENAILS TO'TOP PLATE NOTE: BOTTOM SPLIC PLATE LENGTHS MUST BE OVER STUD AT LEAST 4'-0" LONG. TYPICAL TOP PLATE SPLICE DETAIL 6m� SCALE: N.T.S. � �4 F= 2240 LBS SIMPSON SIMPSON SP4 SP2 P.T. ATE SIMPSON SP4 TRANSOM FRAMING SEE SECTION AA/S1 AND BB/Sl FOR ADDITIONAL DETAILS SIMPSON SP2 - -------- NAILED INTO TRANSOM FRAMING RECESS LINTEL SIMPSON Spi SIMPSON SP4 ON�RECESS SIMPS LINTEL SP4 NAILED INTO TRANSOM FRAMING SIMPSON SP4 SIMPSON Spi SIMPSC SP4 TYPICAL INTERIOR NOW BEARING WOOD FRAME WALL/0" SIMPSON SP4 �_2X TOP PLATE OVERLAPPING 10d NAILS @ 6" STAGGERED J-BOLTS @ 24" O.C. MAX —2X P.T. PLATE SCALE: N.T.S. \�4 2"x BUILT-UP COLUMN, SOLID MEMBER OR SPF) (3075# SPF) - (4565# SPF) (5645# SPF) '(6970# SPF) G (9335# SPF) N. 8" :'OXIED A.T.R. & NUT OXIED A.T.R. t & NUT DXIED A.T.R. t & NUT 2X8 P.T. BOTTOM PrTE - (�)\-5/8"X`10" "J" BOLT @ 24" O.C. MAX. C (MIN. (2) PER BOTTOM PLATE) C SIMPSON SP4 " 4 2X8 P.T. BOTTOM PLATE 5/8"x10" "J" BOLTS @ 24" O.C. MAX. (MIN. (2) PER BOTTOM PLATE) ROOFTRUSSABOVE 2X BLOCKING (2) 16d TOE NAILS EA. BLOCKING 2X8 WALL ABOVE ENTRY K.O. BLOCK W/(1) #5 CONT. & FILLED 5/8"X10" J-BOLTS @ 2-4- O.C. -MASONRY WALL d NAILS@ 4 A 1 Od NAILS @ 6" O.C. STAGGERED STAGGERED TRANSOM FRAMING 0 M 0 6 BEYOND. N - - -1 -PLYWOOD FASTENED TO TRUSSES L WITH 8d COMMON WIRE NAILS @ 4" PLYWOOD O/C BOUNDARIES 6" O/C EDGES SHEATHING & 8" O/C FIELD 1 0 SIMPSON SP4 w/ (6) 1 Od x 1 12" (USE SP6 FOR 2x6 WALL, USE .—PLYWOOD SP8 FOR 2x8 WALL) SHEATHING S1 MPSON SP2 w/ (12) 1 Od NAI LS MASONR 0 SIMPSON SP1 W/ (10) 10d NAILS WALL BELOW o1_5/8"X10"J-BOLTS@24"O.C. MAX. (MIN. (2) PER BOTTOM TE) ALTERNATE: 5/8" DIA. ATR EPDXIED MIN. 6" INTO BOND BEAM @ 24" O.C. FRAMING DETAILS ABOVE ENTRY rR SCALE: N.T.S. C,4 .,.N � . ........ N S -�- , - .. /r/ -1., . .1 To the best of the Engineers knowledge, information and belief, the structural plans and specifications contained within these drawings comply with the 2020 Florida Building Code - Residential 7th Edition. Engineers signature and seal is only for the structural engineering portions of the drawing pages bearing ng nee s si n ure an sea. ­ I_. r, W co E r- s !a _j z N 6 S, _j u- 0 CMO ID U;- M UD) r'2 1Z uj EL o a. _j ul� U_ W 0 . I z :� -.0 ;; . r_ . C', Z W =, % ,� 0 _j _j W 0 r-;; q ce W U) 0) . z " �', r- U� C'I z of Ln 0 co N < d 0 z W 1-10 D 0 < 0 U 0 Ln CLI U E Av 8 i4 0 N M_ r- z 1! z _j E 0 E 55 0 z ru CD E M -0 0< CN LH O� '0 0 z U) __j .9 1 1z < '0 0 z 2 C:) 0 C:0 0§ .2 0 ca 00 0 0 > (D 10-1-1 < > 0 0- %_ .2 0 (.0 17— C 0 E L_ 04 co C) Lo _r N LO cv) a) LO 04 00 04 E N M z E 0 ca C E 0 '10 0 �0 ca _j I < 0 ID _j JOB NO 21-2029 SCALE AS NOTED SHEET NO. S4 SIMPSON HGAMV W/ (4) 1/4"xl 1/2" SDS SCREWS TO BLOCKING & (i 1/4"X2 3/4" TITEN TO CMU 2x4 #2 SYP BLK'G @ 16" O.C. w/ (2) 16d NAILS EA. END. SEE SCHEDULE - [RSH] - ON FRAMING SHEET FOR SHEATHING AND FASTENERS. (MIN. FIRST 4 BAYS) SEE STRUCTURAL NOTES AND NAILING TOENAIL w/ SCHEDULE FOR SHEATHING DETAIL-7 (2) 16d NAILS --- 2x4 #2 SYP BLK'G @ 16" O.C. w/ (2) 16d NAILS EA. END. SEE SCHEDULE - [RSH] - ON FRAMING SHEET FOR SHEATHING MAX. 9" AND FASTENERS. (MIN. FIRST 4 BAYS) IF >9" SEE 10/S5 UNSUPPORTED, BACKNAIL w/ (2) 16d NAILS 2x4 #2 SYP BLK'G @ 16" O.C. w/ (2) 16d NAILS EA. END. MAX. 9" SEE SCHEDULE - [RSH] - ON FRAMING SHEET FOR SHEATHING UNSUPPORTED, AND FASTENERS. (MIN. FIRST 4 BAYS) IF >9" SEE 10/S5 BACKNAIL w/ (2) 16d NAILS SEE STRUCTURAL NOTES AND NAILING t7N SCHEDULE FOR SHEATHING DETAIL 41'± 45'± z 7- 45* SEE STRUCTURAL NOTES AND NAILING SCHEDULEFOR 2x4 CRO 3 BRACE SHEATHING DETAIL--/ KI 2x4 KICKER 2x8 SYP#2 1" BRACE TO APPROX. 8" FROM RIDGE FASTENED AT SKER @4 8._O�O/C @ 8--o" O/C. EXTEND AT LEAST 90% OF EACH JOINT W/ (3) 10d 1" BRACE TO EXTEND 2x4 CROSS BRACE WEB LENGTH & NOTCH AT & (2)10d TOE NAILS @ AT LEAST 90% OF WEB APPROX. 8" FROM BOTTOM CHORD (SEE TABLE) EA. END @ 48" O.C. LENGTH (SEE TABLE) RIDGE FASTENED AT S I M PSON H2.5A w/ (10) 8d 2x8 P.T. GABLE TRUSS EACH JOINT w/ (3) 1 Od & FROM LEDGER TO SILL 1/2" CDX PLYWOOD OR (2)1 Od TOE NAILS @ EA. BLOCKING F7/16" OSB SHEATHING END GYPSUM WALL BOARD ATTACHEDW/10d GABLETRUSS NAILS @ 6" O.C. EDGES 2"x4" PANEL BLOCKING @ 48" O.C. FOR THE FIRST 1/2" CDX PLYWOOD OR 7/161, AND 12" O.C. FIELD (4) ROWS OF TRUSSES FROM EA. END TYP. BOTTOM OSB SHEATHING ATTACHED 1 OdX3" @ 3" O/C CORD ATTACHED W/ (2) 16d TOENAILS wl 10d NAILS @ 6" O.C. I r%n T E I W. 1. THROUGH CHORD 2"x4" LEDGER (MATCH BOTTOM CHORD EDGES AND 12" O.C. FIELD INTO 2"x6" P T PLATE SLOPE OF ADJACENT SCISSOR TRUSS) 2x4 #2 SYP BLK'G @ 16" O.C. w/ (2) 16d NAILS EA. END. SEE SCHEDULE - [RSH] - ON FRAMING SHEET FOR SHEATHING AND FASTENERS. (MIN. FIRST 4 BAYS) MAX. 9" UNSUPPORTED, BACKNAIL w/ (2) 16d NAILS MAX* 9" IF >9" SEE 10/S5 SEE STRUCTURAL NOTES AND UNSUPPORTED, NAILING SCHEDULE FOR SHEATHING� IF >9" SEE 1 O/S5 DETAIL DOUBLE TOP PLATE 2"x4" CROSS BRACE 2x4 CROSS BRACE APPROX. 8" APPROX. 8" FROM FROM RIDGE FASTENED AT RIDGE FASTENED AT L" BRACE TO EXTEND EACH JOINT w/ (3) 10d & (2) 10d EACH JOINT w/ (3) /-AT LEAST 90% OF WEB TOE NAILS @ EA. END 10d & (2) 10d TOE LENGTH (SEE TABLE) 2x FRAME WALL (SEE WALL NAILS @ EA. END GABLETRUSS SECTION FOR SIZE & SPACING) 2x4 PANEL BLOCKING //-1/2" CDX PLYWOOD OR 1/2" CDX PLYWOOD OR 7/16" @ 48" O/C FOR THE (2) 16d /-7/16" OSB SHEATHING OSB SHEATHING ATTACHED FIRST (4) ROWS OF NAIL ATTACHED w/ 10d NAILS W/ 10d NAILS @ 6" O.C. EDGES TRUSSES FROM Ek @ 6' O.C. EDGES AND 12" AND 12" O.C. FIELD END TYP. TOP & O.C. FIELD BOTTOM ATTACHED � (2) 16d NAILS W/ (2) 16d TOENAILS ' 2x4 "T" ON TOP OF PANEL I . . 1 2x4 "T" ON TOP OF PANEL BL KING WEEP SCREED 74" P.T. SILL NOTCH 1" BRACE HERE THE FIRST (4) ROWS OF TRUSSES 1 Odx3" @ 4" O/C Oc 2x4 PANEL BLOCKING @ 481, O.C. FOR 2x BLOCKING BLOCKING, FASTEN WITH FASTEN WITH 1 Odx3" @ 4" O/C SPACED 2x4 "T" ON TOP OF PANEL @ 48" O.C. INSTALLED PER MANUF. 1/2" x 8" "J" BOLT @ 48" O.C. \-WEEP SCREED FROM EA. END TYP. TOP & BOTTOM BLOCKING, FASTEN WITH SIMPSON HGA10KT w/ (4) 1/4"xl 1/2" SDS SCREWS TO SIMPSON METAII 2 w/ (7) 1 0dx1 1/2" NAILS AT 6'-0" INSTALLED PER MANUF. ATTACHED w/ (2) 16d TOENAILS TRUSS & (4) 1/4"x3" SDS SCREWS TO PLATES AT 24" O.C. MOISTURE BARRIER 1 Odx3" @ 4" O/C 1/2"x 8" "J" BOLT @ 32" O.C. MINIMUM 6" FROM O.C. MAX w/ MIN. 4" EMBEDMENT IN KO BLOCK - MOISTURE BARRIER PLATE SPLICES w/ 3/16"x2" 0 PLATE WASHER META12 w/ (7) ALTERNATE SIMPSON MSTAM24 w/ (7) 10d NAILS NOTE: IF EMBEDDED -SIMPSON 1 Odxl 1/2" NAILS AT EA. & (4) 1/4"x2 1/4" TITEN @ 4'-0" O/C ALIGNED WITH STRAP MISSED VERTICAL SECTION TRUSS VERTICAL WEB (24,- GABLE WEB SECTION r2 WEB, USE MSTAM36 wl (7) O.C. MAX) w/ MIN. 4" 1 Od NAILS & (4) 1/4"x2 114" SCALE: N.T.S. EMBEDMENT IN KO BLOCK SCALE: N.T.S. �5 TITEN ON OUTSIDE 2x4 #2 SYP BLK'G @ 16" O.C. w/ (2) 16d NAILS EA. END. SEE SCHEDULE - [RSHI - ON FRAMING SHEET FOR SHEATHING - REFER TO DETAIL J AND FASTENERS. (MIN. FIRST 4 BAYS) ON SHEET S5 FOR X -BRACING, AND TOP M SEESTRUCTURAL CHORD BLOCKING NOTES AND NAILING INFORMATION 00 00 SCHEDULE FOR SHEATHING DETAIL BACKNAIL W/ (2) 16d NAILS -WOOD TRUSSES 00 00 2"x4" CROSS BRACE APPROX. 8" FROM -2X4 RAT RUN BRACING 1 11 2" RIDGE FASTENED AT AT 24" O.C. ON TOP OF EACH JOINT W/ (3) BOTT. CHORD FOR 4 10d & (2) 10d TOE TRUSS SPANS NAILS @ EA. END ATTACHED W/ 2 - 16d AT EA. TRUSS JOINT (2) 2" x 4" LAMINATIONS W/ (1) ROW (3) 2" x 4" LAMINATIONS W/ (1) ROW (3) 2" x 6" LAMINATIONS W/ (2) ROWS OF 2X4 PANEL BLOCKING OF STAGGERED 10d COMMON WIRE NAILS OF STAGGERED 30d COMMON WIRE NAILS STAGGERED 30d COMMON WIRE NAILS @ 48" O/C FOR THE N(2),,16d NAILS (2) 16d NAILS - 2x4 BLOCKING @ 24" (D 0. 148", L 3") OR EQUAL (D 0.207", L 4 1/2") OR EQUAL (D 0.207", L 4 1/2") OR EQUAL FIRST (4) ROWS OF t O/C w/ (2) 16d TRUSSES FROM EA. TOENAILS @ EA. END NOTES: END TYP. TOP & I 1) ADJACENT NAILS ARE DRIVEN FROM OPPOSITE SIDES 4) FOR 4-PLY, PROVIDE 1/4" DIA. x 5 1/2" LAG SCREWS OR EQUAL BOTTOM ATTACHED MASONRY WALL OF THE COLUMN (SPACE AS SHOWN FOR 3-PLY) w/ (2) 16d TOENAILS -ARCHITECTURAL FINISH 2) ALL NAILS PENETRATE AT LEAST 3/4 OF THE THICKNESS 5) FOR 5-PLY, PROVIDE 1/4" DIA. x 7" LAG SCREWS OR EQUAL (SPACE AS SHOWN FOR 3-PLY) / 2x4 BLOCKING-, --2x4 "T" BLOCKING @ 48" O.C. 16d NAIL 11" BRACE ATTACHED W/ 10d NAILS @ 4" O.C. TYPICAL GABLE TRUSS WEB DOUBLE 1" BRACING DETAI'V,' s5 SCALE: N.T S 2X4 "T" BLOCKING 2x4 BLOCKING @ 48" O.C. ---16d NAIL 1" BRACE ATTACHED - W/ 10d NAILS @ 4" 0. TYPICAL 4� 4L GABLE TRUSS WEB SINGLE 1" BRACING DETAILr 6 SCALE: N.T.S. DIAPHRAGM NG @ 48" O/C GABLE TRUSS BLOCKI TRUSS VERTICAL SIMPSON SP2 w/ (12) 10d (2) 2"x8" 1" BRA --7-fl ­2x4 LEDGER (MATCH BOTTOM CHORD DBL. TOP PLATE CE SLOPE OF ADJACENT TRUSS) NAILS AT EACH STUD FASTENED WITH (3) STUD WALL (SEE TYP. SEC.) SECTION SECTION 16d PER SIDE ("3 r4 SCISSOR GABLE "T" BRACE SCALE: N.T.S. �5 SCALE: N.T.S. �5 AS PER HIB 91 SCALE: N.T.S. MAX. 9" UNSUPPORTED, 8d @ TO/C IF >9" SEE I O/S5 r-WOOD TRUSSES 1" BRACE TO EXTEND AT LEAST 90% OF WEB LENGTH (SEE TABLE) -GABLE TRUSS -1/2" CDX PLYWOOD OR 7/16" OSB SHEATHING ATTACHED W/ 1 Od NAILS @ 6" O.C. SIMPSON HGAM 1 OKTA W/ (4) E ES AND 12" O.C. FIELD 1/4"xl 1/2" SDS SCREWS TO BLOCKING & (4) 1/4"X2 3/4" JACKTRUSS TITEN TO CMU SEE PLAN FOR ,qq!NECTION OF THE LAST LA 2x4 "T" ON TOP OF PANEL­ 3) EACH 30d COMMON NAIL MAY BE REPLACED W/ (2) 16d 6) REFER TO NDS SECTION 15.3 FOR ADDITIONAL INFORMATION BLOCKING, FASTEN WITH L 2X4 BLOCKING W/ EXT. WALL CONN. (@ 1 Odx3" @ 4" O/C (2) 12d TOENAILS COMMON NAILS. (ONE INTO EACH OUTSIDE FACE OF NON - LOAD BEARIffG LOCATION rD B.U.C., SAME NUMBER OF ROWS, SAME SPACING) SECTION SEE TYP. WALL SECTION FOR SCALE: 3/4" V-0" TYPICAL NAILING SCHEDULES FOR BUILT-UP COLUMNS r8 (" 9 ADDITIONAL INFORMATION. 4INIMUM 2x 'ROSS BRACING SEE PLAN FOR OCATIONS) (2) 16d PER JOINT CONTINUOUS BOTTOM CORD BRACING 2"x4" MIN. SEE M/S5 CROSS BRACING DETAIL rj_"'� 12 6.9 MAX. SCALE: N.T.S. TOENAIL i (2) 16d NA 12" SEE RSH SCHEDULE FOR ATTACHMENT 2X4 #2 SYP BLK'G @ 16" O.C. (2) 10d x 0.131" TOENAILS EA. SIDE CONT. 2X4 #2 SYP W/ 1 Od XO. 131 @ 8" O.C. ALTERNATE NON -DROP GABLE END DETAIL SCALE: N.T.S. GABLE TRUSS S5 1" BRACE W/ 10d @ 4" O.C. /—(SEE SCHEDULE FOR SIZE AND LOCATION) S5 S5 J1 - 1� CONT. BEARING GABLE END BRACING DETAIL MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION SCALE: N.T.S. SCALE: N.T.S. PRE-ENGINEERED WOOD TRUSSES SCALE: N.T.S. OVERLAP TRUSS BRACING 6" OVERLAP AT LEAST TWO TRUSS SPACES \-MINIMUM (2)16d PERJOINT \-MINIMUM 2X4 TRUSS BRACING TRUSS BRACING OVERLAP DETAIL rM SCALE: N.T.S. S5 1' BRACE W/ 10d @ 4" O/C (SEE SCHEDULE FOR SIZE AND LOCATION) 2 x 4 BLOCKING wl (2) 10d 24" O/C (TYP) TOE NAILS AT EACH END @ z W \-BRACING w/ (3) 1 Od x 3" AT EACH CONN. @ 24 O/C -MOISTURE BARRIER -BOND BEAM - MASONRY WALL ARCHITECTURAL FINISH EXT. WALL CONN. @ NON LOAD BEARING LOCATION (UNEVEN CLG.) SEE TYP. WALL SECTION FOR SCALE: N.T.S. s5 ADDITIONAL INFORMATION. 1" BRACING REQUIREMENTS STUD SPACING NO 1" BRACE (1) 2"x4" (U.N.O.) 1" BRACE 2"x6" (U.N.O.) 1" BRACE 24" 0'0" - T-O" 31-0" - 6'-0" 6'-0" & GREATER SCISSOR GABLE — (1) 2"x8" #2 S.P.F. @ EACH VERTICAL AND (2) 2"x8" FULL HEIGHT @ DIAPHRAGM BLOCKING NOTE: 1) 1" BRACE MUST EXTEND AT LEAST 90% OF WEB LENGTH EXCEPT, SCISSOR GABLE WHICH REQUIRES BRACE TO EXTEND FULL HEIGHT OF GABLE. 2) 1" BRACE TO BE FASTENED TO GABLE STUD WITH 10dx3" NAILS @ 4" O/C. 3) SEE 6/S5 FOR MORE INFO. SIMPSON HGA10KT W/ (4) 1/4"xl 1/2"SDS SCREWS TO TRUSS & (4) 1/4"x3" SDS SCREWS TO PLATES (TYP.) /—CiABLE TRUSS \---STUDS @ 16"O.C. GABLE END BRACING DETAIL SCALE: 3/4"=V-0" MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION SIMPSON SP2 w/ (12) 10d NAILS AT EACH STUD ENDJACK 1 V-0" MAX. W 0 CORNERJACK < W z 0 HIP FRAMING REFERENCE PLAN 20'-0" MAX 20'-0" MAX "X" BRACE SEE DET. J/S5 n CONTINUOUS BOTTO� CHORD BRACING 2X4 MIN. bl'o. 1 um NOTE: ZTOP CHORD 2X4 #2 SYP BRACING 1) SEE TRUSS MANUFACTURER'S TRUSS ENGINEERING ZBOTTOM @ 16" O.C. MAX. FOR FIRST (4) CUT SHEETS FOR ADDITIONAL PERMANENT BRACING BAYS THAT MY BE REQUIRED CHORD GABLE END BRACING 2)"T" BRACING MAY BE USED IN PLACE OF PERMANENT @ 4'-0" O.C. MAX. FOR FIRST (4) BAYS BRACING PROVIDED IT EXTENDS OVER AT LEAST 90% OF THE WEB. REQUIRED MINIMUM PERMANENT TRUSS BRACING PLAN AS PER BCSI SCISSOR TRUSS SCISSOR TRUSS W/ DROP CEILING BRACING DETAIL SCALE: N.T.S. 2X4 BRACING @ 48" O.C. CONTINUOUS TO FIXED LOCATION ATTACHED W/ (2) 10d AT EA. TRUSS (NOTE: BRACING MAY BE PLACED ON EITHER TOP OR BOTTOM OF THE BOTTOM CORD) COSMETIC DROP CEILING FRAMING MEAN ROOF HEIGHT UP TO 30'-0" SCALE: NTS SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION WOOD FRAMED GABLE END BRACING DETAIL MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES SCALE: N.T.S. FOR WIND SPEED SPECIFICATION C14 CID C=> E�VKo- N v C_ k ...... To the best of the Engineers knowledge, information and belief, the structural plans and specifications contained within these drawings comply with the 2020 Flodda Building Code - Residential 7th Edition. Engineers signature and seal is only for the structural engineering portions of the drawing pages bearing Engineers signature and seal. 101' E In 00 C) M 8 cc C> Cq '. 6 ' Lo �! 2 --. 0 s 'm con) it L� Lu 0 to r- P-� 04 0 0 Irf ' '! W a- .4 M u_ (n a- Lu M 0 -, - z :�� _. . 0 � W I R 9 2 9 C' ow W W (n < < 00 z M Z _j CL w Ln 0 < a 0, 6 3 Loo z W -10 E R3 < draft GX U 0 un U) U E 8 a; - U) L 0 11 _2� — 0 CD CO U_ c6 E g- 0 H E z E 0 1 .0 D. 0, z t <� �O 2 .5 1 Cn C: < P! - .I '0 0" z -Z z 0M 0< 'z n 0 U CL — �z W C-3 < M c:) co 'z 0 M > 0 0) (D 00 C) > CD < > x -;.i 0 1 0 C: M C 0 E L_ CN co CD Lo z: CN CY) 0) T_ C14 00 0) N 0) c) 0 E cc z a E E 0 '6 JOB NO 21-2029 SCALE : AS NOTED SHEET NO. S5 C71 t2 C) C'4 CD C' 1 4 C=) (If q) C14 C> C14 =0 C14 C14 6 0- E E 0 2 15 C, 2 C1. E .2 t5 C> C14 0 C14 Co C/) 1X4 1 x4 1/2" DRYWALL DOOR JAMB (REFER 1x4 1/2" DRYWALL DOOR JAMB (REFER 1x4 1/2" DRYWALL F 4%# UNACCEPTABLE INSTALLTION 40 DOOR JAMB (REFER TO PRODUCT P.T. TO PRODUCT F P.T. F TO PRODUCT PROPER INSTALLATION MAX. 8" DO NOT DO THIS 2"x BOT. PLATE W/ (2) 10d @ 6" O.C.. E X/ APPROVAL FOR CONN. APPROVAL FOR CONN. X 4 APPROVAL FOR CONN. x4 TF #5 REBAR (TYP,) 3/4" PLYWOOD DECKING GLUED ATTACHED WALL SHEATHING TO )T/1 x4 P.T- 3/16"0 X 3" LONG FURRING FURRING FURRING (2) ROWS 3/16" x 3-1/2" #5 REBAR AND NAILED W/ 8d COMMON @ 6" O.C. EDGES AND 12" O.C. FIELD 2X BOTTOM PLATE W/ 8d @ 4" O.C., 2 ROWS STAGGERED 3-1/4" LONG X 3/16"0 TAPCONS TAPCON @ 16" O.C. &114"2X8 TAPCON. INTO (TYP,) STAGGERED @ 16" m 1 Y2 BLOCK@ SPACING O.C. 2-ROWS INTO 1x8 P.T. FROM EACH END w/ MIN. 1X8 4 PER MANUFACTURE 1" DETAIL 2" EDGE DIST. ATTACH MASONRYTHROUGH 1-1/2" DETAIL 1x8 w/ (2) ROWS 8d NALS 3" DETAIL 90- HOOK (TYP.) STD. 90^ 41%* 2x BAND JOIST W/ FACE NAIL 1 Od @ TOP & BTTM CHORD, AND (8) 1x4 P.T. & 1x8 P.T. STAGGERED @ 12" O.C. FILL SOLID HOOK (TYP.) BOTH CELLS FACE NAILS 10d @ TRUSS VERT. WEB 3/16" x 3 -1/2" TAPCON @ 16" 1x4 P.T. DOOR JAMB (REFER TO PRODUCT JLJI METAL SEAT PLATE O.C. & 4" FROM D OOR JAMB (REFER 1/2" DRYWALL 1/2" DI NOTE: N. 1 x4 APPROVAL FOR CONN. 1x EACH END W/ MIN, TO PRODUCT 4 E -1 ILV LAP SHEATHING TO DOOR JAMB (REFER APPROVAL FOR CONN. 2"EDGE Dl,,:S- �j 6". TO PRODUCT 2" EDGE DIST. 2x8 P.T. w/ (2) ROWS 3/16" BOTTOM OF BAND JOIST TYPICAL APPROVAL FOR CONN. (2) ROWS 3/16" x 3-1/2" x 3-1/2" TAPCON @ 16' 1x4 O.C. & 4" FROM EACH O.C. & FURRING TAPCON @16 END w/ MIN. 2" EDGE DIST. DIST 4" FROM EACH END wl L 2x8 P.T. ATTACH SECOND PLY w/ W/ 4111� 'MWEB 0) FIRST COURSE NOTC SIMPSON HGAM 1 OKTA @ 12 O.C. w/ (4) 1/4xl 1/2" SDS SCREWS 'n r MIN. 2" EDGE DIST. X8 x P.T. AS REQ'D (2) ROWS 10dx3" 2x 2 P T A" INTO BAND JOIST & (4) 1/4"x2 3/4" TITEN INTO K.O. STAGGERED @ 12" O.C. 2x DETAIL 2 1/4" DETAIL 3-1/4" DETAIL NOTCH WEB AT THE ±5" FIRST 2 COURSES BLOCK BUILDOUT OVER SIZE DOOR -WINDOW ROUGH OPENINGS� �CC LED CELL PER �H FOUNDATION PLAN FILLED CELL INSTALLATION � RETROFIT FOR MISSING EMBEDDED STRAP SCALE: N.T.S. SEE TYP. 2-STORY WALL SECTION FOR ADDL. INFO SCALE: N.T.S.- SCALE: N.T.S. 2x8 P.T. BUCK -CONNECT TO BLOCK SECTION A -A UPLIFT CAPACITY = 805 # FOR 1 STRAP SEE ARCH PLAN AND PRE-ENG TRUSS DESIGN W/ 1/4" x 3 1/4" TAPCON ( 1 1/4" M IN. = 1610 # FOR 2 STRAPS SEE NOTE 1 BELOW FILL 1 st 4 COURSES SOLID W/GROUT EMBEDMENT INTO BLK.) 1/4" MAX 2- 8" 1 PLY PRE-ENGINEERED TRUSS 1 X 4 FURRING SOLID BLKG. AT TOP BTWN. 1/4" x 3 1/4" TAPCONS ARCH BLKG. & BUCK BLOCK HEADER Z SIMPSON HM9KT w/ (4) 1/4"xl 1/2" SDS 1/2" DRYWALL SCREWS & (5) 1/4" x 2 1/4" TITEN (IF TRUSS IS 2 PLY INSTALL SIMPSON LGT2 w/ (16) 16d ALUM DRIP EDGE 8d NAILS AT 8" O.C. AT BUCK SINKERS AND (7) 1/4"x2 1/4" TITEN = 2150 #) BRG WALL TYPE 2 x 8 45' DIAGONAL (4) 10d NAILS INTO --LEAVE INTO A CUT OUT IN O.S.B. ON THE PER PLAN 2x SUB FASCIA BLKG BRACE(S) 2 x 8 BRACE/ BLKG. 7/16" OSB INSIDE TO ALLOW FOR INSULATION TO BE INSTALLED BOND BEAM OR CAST IN PLACE BEAM 2x2 #2 P.T. MIN, FOR OVERHANGS BETWEEN OVER 1 1/2" i BUILT UP PLWD. BUCK ARCH PANEL CUT HOLE IN O.S.B. FOR IN THIS AREA POLY CELL IN �H jS AREA 2 x 8 45 DrAGONAL BRACE AT EA. FASTENED PER NOTE 2 BELOW L CONTACT ENGINEER OF RECORD FOR FURTHER INSTRUCTIONS. � 1. . . ... ... ... Al -CELL SCRIBE (NOTCH) FACE OF ARCH W/ (3) 10d NAILS CONT VENTED OR SOLID SOFFIT L . — I n I td all 0 INTr) , e ) v Sz BACKSIDE TO FIT ARCH (4) 1 Od NAILS INTO 2 x 8 AT EA. END RETROFIT TRUSS DETAIL CONT 2x4 NAILED TO -1 9x BLOCKING NAILED TO TOP OVERHAN A CONNECT W/ 8d NAILS BRACE/ BLKG. BLOCKING w/ 2-12d NAILS CHORD EVERY OTHER TRUSS \-PROVIDE N.T.S. w/ 3-12d NAILS, TYP. \_2 x 4 SOLID BLKG. (FULL WIDTH OF WALL) BTWN. OSB INSTALL WDW. SCREW ANCHOR-' ARCH FACES W (4) 1 Od NAILS THRU OSB INTO 2 x 8 TAPCON WITHIN 1 . G.C./ BUILDER TO VERIFY/PROVIDE SOFFIT MATERIAL SPAN CAPACITIES BASED RETROFIT WALL OVERHANG DETAIL (NTS) INTO ARCH BLKG. PER 4" MIN. OF BRACE ON THE DESIGN PRESSURES SPECIFIED FOR COMPONENTS AND CLADDING INSTALLATION DETAILS A -A PROVIDE TAPCON PER WDW. INSTALLATION DETAILS OR THRU 2X6 SYP #2 CONT. (MATCH TRUSS DEPTH LISTED IN THE DESIGN CRITERIA ON SHEET SN. FOR OVERHANGS BETWEEN 3/4"TO 1 112" 1-1/2" THK. OR MORE BUCK WITHIN 6" MIN. OF START OF ARCH IF TRUSSES USED) W/ (3) #6 X 4%" WOOD 2. 2x2 #2 MIN. P.T. w/ J-CHANNEL SECURED @ 24" O.C. FASTEN TO: FNOTE FOR OVERHANGS LESS THAN 3/4" - NO REPAIR REQ'D. 77771 START OF ARC SCREWS @ 16" O.C. MAX. OR IF MASONRY WALL - CMU w/ 3" LONG T-NAILS @ 24" O.C. 4'MAX. RAD. USE (1) SIMPSON 1/2" HD TITEN (CENTERED) w/ - WOOD wl 0.148"x 3 1/4" @ 16" O.C. ARCH DETAIL MIN. 4" EMBEDMENT AT 16" O.C. 3. [F] CHANNEL APPLICATION: 2X2 NOT REQUIRED SEE (PA) INSTALLATION GUIDE 11-0" 51-011 SCALE: N.T.S. 1�11 �S 12 L , 11 JACK TRUSS PROVIDED BY SEE STRUCTURAL SOFFIT I I TRUSS COMPANY OR PLAN 2x6 #2 SYP @ 24" O.C. SF01 SCALE: 3/4" = V-0" (--) FOR SOFFITS V-4" & GREATER & OlLf IN ISH FLOQ 3 2 x 8 BUCK - CONNECT TO BLOCK SECTION ROOF SHEATHING ATTACHED REV. 02.01.2021 BLOCKING REQUIRED, FOR SOFFITS LESS A . =Kj= F WITH 1/4" x 3 1/4" TAPCON (11/4' MIN. B-B PER NAILING SCHEDULE LL THAN V-4" MID BLOCKING NOT REQUIRED __--#5 EMBEDMEN /4" MAX 2-4- 8" *REFER TO THE PRODUCT APPROVAL FOR INSTALLATION DETAILS.* A , A 1110 BAR BLOCK HEADER SOLID BLKG. AT TOP BTWN. ARCH (5) 12d NAILS SIMPSON . .0" V CENTERED W/ IN TOP 1 X 4 FURRING BLKG. & BUCK 2X6 TO 2X4 H2.5A w/ (10) 8d NAILS 2 X 4 #2 SYP SCAB TO SIDE OF A 9 KNOCKOUT/ N TRUSS AS SHOWN FOR O.H. UP TO 2'-6" CHAIR BLOCK 8d NAILS @ 8" O.C. AT BUCK DOUBLE 2x4 SCAB FOR 2'-6" TO 4'-0" O.H. A 2 x 8 VERT. W/ (2) 1 Od NAILS AT EA. END PROVIDE 2x r 0 (2) 10d NAILS @ 8" O.C. % MONO FOOTING 11 A. PROVIDE 2 x 8 DIAG. BRACE BTVVN,\ PROVIDE (2) MIN. : CONT. W/ (3) 4 TO TRUSS TOP CHORD — I C_ - . . SIZE AND REINF. PER PLAN E VERT. BRACES WHEN HGT. OF TAPCON AT EA. SIDE BUCK WITHIN 4" 12d NAILS + + �AtQ r + PLYWOOD SHEATHING AND SECTION DETAILS - - BRACE EXCEEDS 24" - (1) JACK TRUSS PROVIDED By—/ + S B ON T LEAVE A CUT OUT IN O.S.B. ON T MIN. OF START OF TRUSS COMPANY OR 2x4 + + CLEAN FILL A 2 x 8 VERT. BRACE(S) )0 1��ULATION INSIDE TO ALLOW FOR INSULATION ARCH #2 SYP @ 24" O.C. + + .0. . DIRT TO BE INSTALLED 00, 00, + BLOCKING AS 4'-0" MAX SEE PLAN + REQUIRED A. . CD BUILT UP PLWD. BUCK - SCRIBE (NOTCH) BACKSIDE 7/16" OSB ARCH PANEL 2X4 SYP #2 CONT. (MATCH TRUSS DEPTH + TO SUPPORT ffTANDARD i gy HOOK #5 BAR IN TO FIT ARCH CONNECT W/ !::I NOTE: IF TRUSSES USED) W/ (2) #6 X 4Y2' 'WOOD TRUSS + + SOFFIT + FILLED CELL 8d NAILS �-2 x 4 SOLID BLKG. (FULL WIDTH OF WALLS) START OF ARC 4'MAX. RAD' SHED ROOF ENDS TO BE SCREWS @ 16- O.C. MAX. OR IF MASONRY 2X4 Syp % INSTALL WDW, SCREW BTWN. OSB ARCH FACES W/ (4) 10d NAILS EQUAL EQUAL GABLE ONLY, CORNERS WALL USE (2) 1/4" X 3 1/2" TAPCONS AT 16" EACH TRUSS 273ta= !k THRU OSB INTO 2 x 8 _'N� SHALL NOT BE FRAMED AS O.C. '\\— ANCHOR INTO ARCH BLKG. rK HIP. STEMWALL FOOTING SIZE AND PER INSTALLATION DETAILS B-B ARCH DETAIL DESIGNED ONLY FOR THE SECTION Q ENTRY rL CONNECTOR REINF. PERLAN AND STEMWALL MONO TO STEMWALL FOOTING SCALE: N.T.S. �, INSTALLATION OF SHINGLE SCALE: 3/4" V-0" 1\ SECTION DETAILS �S I AND METAL ROOF FINISH �S SEE LINTEL SCALE: 3/4" = V-0" I SCHED. GLASS BLOCK INSTALLATION NOTES ENTER SOOIT NOTE: IF RETROFIT FILLED CELL CONDITIONS EXCEED (3) PER PROJECT, A) COVER SILL AREA WITH A HEAVY COAT OF ASPHALT EMULSION. ALLOW EMULSION TO DRY CONTACT ENGINEER OF RECORD FOR ADDITIONAL INSTRUCTION. AT LEAST 2 HOURS BEFORE PLACING MORTAR. PRECAST LINTEL IS% B) ADHERE EXPANSION STRIPS TO JAMBS AND HEAD. MAKE CERTAIN EXPANSION STRIP EE ELEVATION EXTENDS TO SILL. FOR OVER HANG EXISTING BOND BEAM. C) SET A FULL MORTAR BED JOINT, APPLIED TO SILL. MASONRY WALL. SEE PLAN FOR -(MAX. 4'-0") L�1� D) SET LOWER COURSE OF BLOCK. MAINTAIN A UNIFORM JOINT WIDTH OF 3/8" PLUS OR MINUS REINFORCING. PROVIDE LOWER HOOKED DOWEL lu� DRILL 3/4"x5" MIN. HOLE SET BAR IN 1/8". ALL MORTAR JOINTS MUST BE FULL AND NOT FURROWED. ALL MORTAR SHALL BE "S" "N't. EXPANSION STRIP SECTION Q ROOF EXTEN SION rM EPDXY CAP TO PREVENT LEAKAGE . LACE TYPE OR STEEL TOOLS MUST NOT BE USED TO TAP BLOCKS INTO POSITION (P A RUBBER CRUTCH TIP ON END OF TROWEL TO TAP BLOCK INTO POSITION.) DO NOT 20 ga. PANEL SCALE: 3/4" V-0" S TOP SPACE BETWEEN EXISTING GROUT & NEW GROUT REALIGN, TAP, OR OTHERWISE MOVE BLOCK AFTER INITIAL PLACEMENT. FOR SOLID GLASS ANCHOR - MUST BE PACKED WITH NON -SHRINK GROUT (USUALLY 2") BLOCK IT MAY BE NECESSARY TO USE WEDGES IN THE MORTAR JOINTS OF THE LOWER - W W M AT PERIMETER 1/ COURSES TO PREVENT THE MORTAR FROM BEING "SQUEEZED" OUT. 1/4" EXPANSION BOLT (2 (1) #5 BARS CONT. - WHERE THIS CONDITION #5x6'EMBEDDED INTO EXISTING BOND BEAM E) INSTALL PANEL REINFORCING IN EVERY OTHER MORTAR BED HORIZONTALLY AND IN JOINTS 9 ga. PANEL PER ANCHOR) - OCCURS TOP WITH MIN. 3" SEE SHEET D2 AND z IMMEDIATELY ABOVE AND BELOW ALL OPENINGS WITHIN PANELS. (THE SAME SPACING REINFORCING COVER 61-01, SIMPSON HTT4 w/ (18) 10d x 1 FLOOR PLAN FOR 0 U) SHALL APPLY TO PANEL ANCHORS WHEN USED AT JAMBS AND HEADS IN LIEU OF CHANNEL (EVERY OTHER 1/2" NAILS TO STUDS & (1) - A MORE INFO < M FILL CELL FULL HEIGHT W/ OR CHASE SURROUNDS.) RUN REINFORCING CONTINUOUSLY FROM END TO END OF PANELS. COURSE) EXPANSION STRIP LAP REINFORCING NOT LESS THAN 6 INCHES WHENEVER IT IS NECESSARY TO USE MORE %4 5/8" DIA. ALL THREAD ROD U_ 0 9 NON SHRINK GROUT. THAN ONE LENGTH. DO NOT BRIDGE EXPANSION JOINTS WITH REINFORCING. INSTALL EPDXIED w/ SIMPSON "SET" Uj rA REINFORCING AS FOLLOWS: EPDXY MIN. 6" EMBEDMENT & PLACE LOWER HALF OF MORTAR IN BED JOINT. DO NOT FURROW. .�:, SEALANT .. 3" MIN. EDGE DISTANCE ;� a_ F- :5 k #5x6'EMBEDDED INTO PRESS PANEL REINFORCING INTO PLACE. i" MIN. LAP SPLICE W/ EXISTING FOOTING (2) #5x6'IN CONC. COVER PANEL REINFORCING WITH UPPER HALF OF MORTAR BED AND TROWEL REINFORCING PANEL CO FILLED CELL SMOOTH. DO NO FURROW. C14 DRILL 3/4"x5" MIN. HOLE F) PLACE FULL MORTAR BED FOR JOINTS NOT REQUIRING PANEL REINFORCING - DO NOT GRADE SET BAR IN EPDXY FURROW. MAINTAIN UNIFORM JOINT WIDTH. 6" MIN. LAP G) SET SUCCEEDING COURSE OF BLOCKS. SPACE AT HEAD OF PANEL AND JAMBS MUST SPLICE NOTE: C14 REMAIN FREE OF MORTAR. SEE GLASS BLOCK INSTALLATION NOTES. <SEALANT z H) STRIKE JOINTS SMOOTH WHILE MORTAR IS STILL PLASTIC AND BEFORE FINAL SET. AT THIS ot, TIME RAKE OUT ALL SPACES REQUIRING SEALANT TO A DEPTH EQUAL TO THE WIDTH OF THE a SAW CUT SPACES. REMOVE SURPLUS MORTAR FROM FACES OF GLASS BLOCKS AND WIPE DRY. GLASS BLOCK DETAIL t'. \\�(2) #5 REBAR. MIN. T' TOOL JOINTS SMOOTH AND CONCAVE, BEFORE MORTAR TAKES FINAL SET. (REMOVE WEDGES FROM LOWER COURSES OF SOLID BLOCKS AND POINT THE VOIDS WITH MORTAR.) GLASS BLOCK SHALL BE INSTALLED PER THE FLORIDA BUILDING CODE RESIDENTIAL SECTION R160 16" MIN. 01 COVER EA. WAY SECTION 1) AFTER FINAL MORTAR SET (APPROX. 24 HOURS), INSTALL PACKING TIGHTLY BETWEEN EXISTING FOOTING GLASS BLOCK PANEL AND JAMB AND HEAD CONSTRUCTION. LEAVE SPACE FOR SEALING. SCALE: N.T.S. J) APPLY SEALANT EVENLY TO THE FULL DEPTH OF RECESSES IN ACCORDANCE WITH THE SECTION AT DEEP MONO FOUNDATION MANUFACTURER'S APPLICATION MANUAL AND INSTRUCTIONS. RETROFIT FILLED CELL DETAIL K) A MAXIMUM OF 60 SQUARE FEET OF GLASS BLOCK MAY BE INSTALLED IN ANY OPENING. SCALE: 3/4" = V-0" RETROFIT FOR MISSING MSTAM STRAP FOR WIND SPEEDS UP TO 110 MPH*, PER PITTSBURG CORNING RECOMMENDATIONS FOR SCALE: N.T.S. INSTALLATION OF GLASS BLOCK. I I SCALE: 3/4" = V-0" 1 6 Z::� CD. C�! to C14 C:) \,EWKO!vn fit Luz A To the best of the Engineers knowledge, information and belief, the structural plans and specifications contained within these drawings comply with the 2020 Florida Building Code - Residential 7th Edition. Engineers signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. W E it 0 (D 0 q 'o 4t Lu 1-4 cl U_ �LUI Q ca LL LL _j U, 0 z 0 C 9 W W 0 CP :e M < z LL OD z L0 M —1 cr D 0 < 04 Ci (.) < z W <C U) Ln CD Cz Q) cf3 0 V) V) CL_ U) E ca d 00 1 14 <3� 0 C13 Cl> 0 z z < E 0 < 0 E U CU r6 c,:) E 5R '. �0 U0 .. 0, W, �z 0. Q) MW U C> CD C.0 0. 0 031 ­ 0 2 C:) > M t: 00 0 0 11, > a) CN > C:) 0 C.0 M C 0 rl�l E 1- 04 CU C:) U-) 04 LO T 00 C14 0) . . "t CD (D E CY) 0 z C5 z E CD Ca CL E 0 0 _j 2 'a M < 0 (D _j 30B NO: 21-2029 SCALE : AS NOTED SHEET NO. SS ROOF SEE '-'u PLANF__� SHEATHING 2X4 BLOCKING BETWEEN TRUSSES SECT. A -A G.T. ADD 2X4 ALONGSIDE TOP CHORD WHEN REQ'D TO PREVENT PLYWOOD SPAN FROM EXCEEDING MAX 24" SPAN (EITHER SIDE OR BOTH IF REQ'D) PROVIDE 2X4 MIN. BLOCKING AT Q OF HIP/RIDGE, TYP.BETWEEN TRUSSES W/ (2) 12D NAILS EACH END TO TRUSS TOP CHORD TYP, TRUSS N (2) 12D NAILS — AT 12" O.C. MAX HIP G.T (2) 2x8 #2 SYP w, O.S.B. FLITCH PI TOP @ TRUSS E U.N.O. ON ROOF PLAN TYPIC WALL NOTE: PENDING BEAM BEARING LOCATION, THE BEAM CAN SIT ON TOP OF COLUMN w/ (2) SIMPSON HTS20 w/ (24) 1 Od x 1 1/2" NAILS EACH SIMPSON HU46/HUC46 w/ (8) 16d NAILS TO POST & (4) 1 Od NAILS TO BEAM SUPPORT COLUMN BUILT-UP (2) 2x4's OR 44 w/ (2) 1 Od NAILS @ 8" O.C. EACH PLY (SHOWN AS 4 x 4) (2) SIMPSON HETA20 w/ (8) 10d x 1 1/2" NAILS EACH - OR (2) SIMPSON MSTAM36 w/ (7) 1 Od & (4) 1/4"x2 1/4" TITENS EACH TIE BEAM VVI I vu I I I vv"� BEAM @ RAISED ENTRY CROSS BRACING DETAIL (TYP.) HIP/RIDGE BLOCKING DETAIL MASONRY WALL KNEEWALL ENTRY FRONT WALL �C_Y SCALE:NTS SCALE:NTS SCALE:NTS SCALE:NTS JACK TRUSS (AS SHOWN) OR GABLE END SEE TRUSS LAYOUT CLIP EACH TRUSS (SEE ROOF PLAN FOR TYPE) FRAME OUT TO BLOCK EDGE SEE PLAN FOR BEAM SIZE EXTERIOR SHEATHING ATTACHED PER NAILING SCHEDULE 2x SPF #2 AT 16" O.C. BUILDER FRAME RADIUS AS REQUIRED TRUSS NOTES: CONV. FRAMED RIDGE 1. WOOD TRUSS ERECTOR SHALL PROVIDE BRACING ACCORDING TO ANSI/TPl-2014 MAY BE NAILED (TRUSS PLATE INSTITUTE) NOTE THAT THE COMBINED WIND AREA IS GREATER w/ M IN. (4) 12d WHEN BEFORE THE ROOF SHEATHING IS APPLIED, AND BRACING SHALL THEREFORE BE IT LANDS NEXT TO INSTALLED AS THE TRUSSES ARE ERECTED. INADEQUATE BRACING IS THE MOST PRE-ENG. TRUSS COMMON CAUSE OF ACCIDENT IN WOOD TRUSS CONSTRUCTION. FULL BUNDLES OF PLYWOOD SHALL NOT BE PLACED ON TRUSSES. THIS CONSTRUCTION LOAD SHOULD BE LIMITED TO 8 SHEETS OF PLYWOOD ON ANY PAIR OF TRUSSES & SHALL BE LOCATED ADJACENT TO THE SUPPORTS. NO EXCESS CONCENTRATION OF ANY CONSTRUCTION MATERIAL (SUCH AS GRAVEL OR SHINGLES) SHALL BE PLACED ON THE TRUSSES IN ANY ONE AREA THEY SHALL BE SPREAD OUT EVENLY OVER A LARGE AREA SO AS TO AVOID OVERLOADING ANY ONE TRUSS. 2. ALL BRACING (DB,CB,BB) SHOWN ABOVE SHALL BE IN ADDITION TO CONTINUOUS LATERAL BRACING SPECIFIED BY THE TRUSS MANUFACTER ALL LATERAL BRACING SPECIFIED BY TRUSS MANUF. SHALL HAVE ADDITIONAL DIAGONAL BRACES AT 20'-0" O.C. MAXIMUM. 3. ALL BRACES SHALL BE 2X4 NOMINAL DIMENSION LUMBER & SHALL BE ATTACHED W/ (3) 12d NAILS AT EACH TRUSS INTERSECTION. CB 4. ADDITIONAL BOTTOM CHORD BRACING SHALL BE INSTALLED AS REQUIRED BY TRUSS DESIGN WHEREVER ADEQUATE STRUCTURAL CEILING ARE NOT ATTACHED DIRECTLY TO THE BOTTOM CHORD OF THE TRUSS. 5. PROVIDE TRUSS BLOCKING AT ALL TRUSS BEARING SUPPORTS WHERE TRUSS DEPTH EXCEEDS STANDARD HEEL HEIGHT SEE TYP TRUSS BLOCKING DETAILS TYP. HAND FRAMING ABOVE TRUSS 2X4 STUDS & PLATES AT 2'-0" O.C. EACH DIRECTION TYP. U.N.O. 2x8 BLOCKING NAILED @ EACH SIDE w/ (3) 12d NAILS WHEN REQUIRED w/ (2) S I M PSO N HTS20 w/ (24) 1 Od x 1 1/2" NAILS EACH TB . . PRE-ENG. TRUSS 2X4 DIAGONAL AT 8'-0" O.C. 2X4 BLOCKING BETWEEN EA. TRUSS CONT. ROOF SHEATHING AT TRUSS TOP MAX & EACH END ALTERNATE CHORD AT ALL HAND FRAMED AREAS TYP. DIRECTION TYP. DIAGONAL AT 8'-0" MAX 2X4 CONT. AT T & B CHORD TRUSS VERTICAL SCAB 2 x 6 #2 SPF 48" O.C. W/ (4) 1 Od TOP & BOTTOM OR SIMPSON H2.5A w/ (10) 8d NAILS COLLAR TIE EVERY 3rd RAFTER 2x4 SPF 2 (2) #7 x 3-1/2" WOOD SCREW EACH TRUSS OR SIMPSON H2.5A W/ (10) 8d NAILS AT 48" O.C. BEVEL CUTS (OPTIONAL) 2x8 #2 SPF RIDGE BEAM 2x6 #2 SYP RAFTERS FOR SPANS 4FT TO 8FT 2X4 RAFTERS FOR SPANS LESS THAN 4FT @ 2'-O"O.C. MAX. W/ (3) 1 Od COMMON TOENAILS TO TIE BEAM CONC.MASONRY STEEL OR WOOD BEARING SUPPORT A -A ALTERNATE BLOCKING DETAIL @ INTERIOR BEARING 3 SCALE:NTS ----Z—WOOD TRUSS —j A PROVIDE BLOCKING AT ALL TRUSS BEARING SUPPORT WHERE TRUSS DEPTH EXCEEDS STANDARD HEEL HEIGHT TYP. WOOD TRUSS BLOCKING DETAIL SCALE:NTS WOOD WALL OR TRUSS. SEE PLAN VARIES ROOF SHEATHING ATTACHED PER NAILING SCHEDULE 2X4 #2 SPF BRACING @ 16" O.C. W/ (4) 12d _41— COMMON TRUSSES. TOENAILS TO TOP SEE TRUSS PLAN 4"to-1 PLATE & (2) 12d END MIN. (2) 2x4! FOR CONNECTION STRUCTURAL SHEATHING NAILS TO TRUSS 1 ! ATTACHED PER NAILING SPF TOP INFORMATION. BOTTOM CHORD PLATE SCHEDULE ,�,VARIES SEE PLAN VARIES W/ FOR WALL LOCATION "zf�j ROOF SLOPE 2X4 CONT. W/ (2) 16d COMMONS NAILS EACH STUD TYP. T&B TRUSS OR ROOF SYSTEM SHEARTRANSFER EXTERIOR. WALL SCALE:NTS OIL SEE PLAN FOP TOP OF WALL MIN. 2X4 #2 SPF STUDS @ 16" O.C. W/ EXTERIOR SHEATHING ATTACHED PER NAILING SCHEDULE & (3) 12d TOENAILS TO PLATE BELOW M I N. 2X4 #2 SYP P. T. P LATE 4 H W/ 1/2"X8" EPDXY ANCHOR MASONRY WALL SEE @ 3" FROM EACH END & PLAN FOR MORE 16" O.C. MAX. INFO. SECTION @ ENTRY r8 SCALE:NTS SIMPSON LSTA18 w/ (12) 10d NAILS CENTERED AT SPLIT TO TIE BEAMS TOGETHER SEE FLOOR PLAN FOR COLUMN SIZE & ADDITIONAL INF( 3IMPSON HUC410 wl 6d INTO HEADER & Od INTO BEAM - SEE =F PLAN FOR MOI NFO SEE FLOOR PLAN FOR COLUMN SIZE& BASE CONNECTION INFO 7/16" OSB FLITCH PLATE SEE FLOOR PLAN FOR REQ'D ONLY WHEN COLUMN SIZE& BASE INDICATED ON BM. CONNECTION INFO OPTION A SCHEDULEIPLAN OPTION B. COMMON BM. TO POST ATTACHMENT SEE ROOF PLAN FOR BEAM SIZE & CONNECTION INFO. SIMPSON MTS1 8 W/ (14) 10d NAILS TYP. U.N.O. SEE FLOOR PLAN FOR COLUMN SIZE & ADDITIONAL INFO. (WOOD COLUMN SHOWN) CORNER A �� A SEE PLAN FOR SEE PLAN FOR CANTILEVER IF INDICATED SEE FOUNDATION L PLAN FOR MORE INFO SCALE: 3/4"=V-0" COMMON BM. ATTACHMENT rj�8 SCALE:NTS EXTERIOR SHEATHING ATTACHED PER 2X4 STUDS W/ SIMPSON NAILING SCHEDULE V SP1 W/ (10) 1 Od NAILS L� AT BASE SEE J/S6 FOR "I MORE INFO. 2x4 BASE PLATE W/ SIMPSON LSTA30 W/ (22) 10d NAILS OR SIMPSON MTS12 W/ (14) 10d x 1 1/2" NAILS TO FLOOR GIRDER BELOW @ 16" O.C. M 16" FLOOR SYSTE FLOOR GIRDER SEE PLAN FOR SEE PLAN FOR DIRECTION CONNECTION SECTION @ FLOOR �2 CONNECTION K"2 SCALE:NTS SEE 1/S5 FOR ADDITIONAL OUTLOOKER INFO. TRUSS (2) 16d NAILS TO EACH COMMON TRUSS/ FRAMING TYP TOP & BOTTOM kSEE PLAN FOR CANT 7/16" OSB FLITCH PLATE REQ'D ONLY WHEN INDICATED ON BM. SCHEDULE/PLAN OPTION C BM. SPLICE OVER CENTER OF POST MIDDLE SEE PLAN FOR 8d NAILS AT VALLEY TRUSS 4" O.C. INFO. MASONRY WALL BELOW: SIMPSON HETA1 6 w/ (9) 1 Od x 1 1/2" NAILS @ MASONRY WALL 4'-0" O.C. TO GABLE TRUSS OR BEAM A. . BEAM BELOW: SIMPSON HTS20 w/ SEE TRUSS PLAN (24) 10d x 1 1/2" NAILS @ 4'-0" O.C. TO GABLE TRUSS COMMON TRUSS SEE ROOF PLAN FOR CONNECTION SECTION AT HIP GABLE rl 2'� SCALE:NTS 2X4 #2 SYP NAILER. NAIL TO STUDS W/ (3) 16d AT EACH STUD - TOENAIL ROOF AND EXTERIOR EACH TRUSS TO NAILER SHEATHING ATTACHED W/ (3) 1 Od PER NAILING SCHEDULE SEE 2ND FLOOR WALL SECTION FOR ADDITIONAL INFORMATION IF 2x DOUBLE LEDGER, ATTACH FIRST PLY W/ (4) 16d NAILS TO EA. END OF TRUSS THEN ATTACH SECOND PLY W/ (3) ROWS OF 16d NAILS AT 24" O.C. SIMPSON LUS26 W/ (8) 10d NAILS OR IF 2 PLY TRUSS SIMPSON ZSEE LUS26-2 w/ (8) 16d NAILS TO FLOOR FRAMING PLAN LEDGER AND J/S6 FOR MORE INFO. 2X1 0 #2 SYP CONT. LEDGER W/ (3) VERIFY WITH PLAN FOR LOCATION AND DIRECTION 1/2" X 4 1/2" LAG SCREWS ATTACH (IF PARALLEL SEE 2/D2 FOR LAG SCREWS INTO END OF EACH BLOCKING INFO) FLOOR TRUSS, 24" O.C. MAX. (AT EACH SIDE OF G.T. INSTALL (4) LAG MASONRY WALL SCREWS EACH SIDE) (TYPICAL) SECTION AT LOW ROOF SCALE:NTS 2x STUDS @ 16" O.C. W/ SIMPSON SP1 W/ 0 0) 1 Od NAILS AT BASE & SIMPSON SP2 W/ (12) 1 Od NAILS AT TOP 2x BLOCKING BETWEEN STUDS TO TRUSS W/ (2) 12d TOENAILS EACH END (BETWEEN TRUSSES (2) 12d NAILS TO EACH VERTICAL LOW ROOFNVAL STUD) SHEATHING ATTACHE PER NAILING SCHEDULE 2x BASE PLATE W/ (2) 12d NAILS @ 16" O.C. ALONG W/ SIMPSON MTS1 2 W/ (14) 1 Od x 1 1/2" NAILS TO BLOCKING BELOW @ 16 0. C. AA PLYWOOD FLOORING LOW ROOF TRUSS W/--// (2) 2x6 BLOCKING UNDER FLOOR G.T. RAISED BOTTOM CHORD 2nd FLOOR WALL w/ SEE PLAN EXTENSION SEE TRUSS SIMPSON LUS24-2 W/ (16) MANUF. SPEC'S FOR 16d NAILS AT EACH END CONNECTIONS TO G.T. SECTION @ BUMP OUT('39 SCALE:NTS DETAILS & SECTIONS C"! C.0 S b-1 cr': Z Of o..' cy Z To the best of the Engineer's knowledge, information and belief, the structural plans and specifications contained within these drawings comply with the 2020 Florida Building Code - Residential 7th Edition. Engineers signature and seal is only for the structural engineering portions of the drawing pages bearing Engineers signature and seal. ... CD W -0T E co oo 0 N CD r U 0 D 'o L� V) con r-- i-L (D u- uj 13 m u- u- u, `� x 0 �01 at =gq- 5 -F, N w 0 P LL — W W 0 2 05 M < Z o 0 a- IZ u-) z N < W_ Lo 0 6 n 0 z d 0 W CD c' < V) C11 "2 - E o 0 6 C�' u) E U 9 < o z z o z < U_ 2[ 0 E o z� <N U M . o u o E z z W < < o o Fr z z C: C/) I .2 o". 1 1z < 2 cb < lo o z zo n� 1. Lz .11, WCL �_ 3: C-3 < A cD < <_ o mo z-11 .3: 0 C) 0) m — (D �6 00 > < 3i > 2 C) 0 0 co C 0 E co C) 1: CN L0 CY) LO T_ 1:00 C\j 0) . . "t 0) 0 E 4�_ CY) 0 z co z E C) 'A u) a. E 0 -�; 0 U _j 'a < JOB NO 21-2029 SCALE : AS NOTED SHEET NO. D 1 0 -0 :2 C'sl <:) C14 C:) C> C14 :F 7N CD, C'4 E E 0 LZ 0 CJ C�4 C:) C14 CN C) MEANT TO SHOW GENERAL FLASHING AND WATERPROOFING METHODS TO BE USED. 3/8" CEMENT PLASTER 12 MIL DRYLOK CMU - MASONRY BLOCK EXTREME WINDOW FASTENER 1) SEALANT AT 4) SEALANT JOINT WINDOWBUCKTO OUTSIDE EDGE OF MASONRY WINDOW BUCK --2) SEALANT JOINT 5) SEALANT FROM INSIDE EDGE OF WINDOW FRAME WINDOW BUCK ACROSS WINDOW BUCK AND EXTEND TO -WINDOW FRAME MASONRY ATTACHED PER CODE 6) TOOLED SEALANT REQUIREMENTS BEAD BRIDGING CLADDING AND WINE )OW FRAME 3) SEALANT WINDOW FRAME T( WINDOW BUCK ALL THE WAY AROUND, INCLUDING SILL. SCS 06 05 CMU INSTALLATION 6 POINT BUCK AND FENESTRATION INSTALLATION AND INTERFACE JAMB, SILL AND HEAD DETAIL APPROVED SHEATHING APPROVED HOUSEWRAP STRUCTALATH TWIN TRACK 2.5 3/4" CEMENT PLASTER 12 MIL (min) DRYLOK EXTREME APPROVED FLASHING TAPE 'V" SEALANT SOCKET WITH TOOLED APPROVED SEALANT WEATHER RESISITIVE BARRIER HEAD FLASHING TIE-IN INSTRUXTIC 1 . Cut, fold up & temporarily secure % resistive barrier above header to allow tor flashing installation 2. Self -adhered flashing plus head flashing under weather resistive barrier 3. Fold weather resistive barrier back over head flashing and sea] with tape DO NO- BOTTO G FOLD UP WEATHER RESISTIVE BARRIER & TEMPORARILY SECURE WOOD FRAME CONSTR. EXTERIOR SELF -ADHERED FLASHIN SHEATHING BY LAPPING DOWN OVER RIM JOIST AND UP WALL BY 6 IN. SELF -ADHERED FLASHING Scale: NTS FLANGED WINDOW FLASHING INSTALLATION AFTER WEATHER RESISTIVE BARRIER SELF -ADHERED FLASHING HALF ROUND WINDOW SCS 06 02 WINDOW FIN INTERFACE WITH SELF -ADHERED FLASHING EXTRUDED SHOULDER DECK JOIST 2x FRAMEWALL SELF -ADHERED FLASHING PRODUCTS DETAILS TILE FINISH WATER RESISTIVE BARRIERS ARE REQUIRED BEHIND STUCCO PER THE FBC RESIDENTIAL 7TH EDITION (2020) Detail Instructions Refer to the number marked as #9 in each detail that corresponds to the ) in numbered items in the list o instructions below: 1 Install self -adhered flashing in order as shown by numbers 2. Install flashing and weather resistive barrier to form water shedding laps 3. Self -adhered flashing can be substituted for building paper 4. Split the release paper using the ripcord (Split release on demand, embedded in the adhesive layer) - for ease of installation andto minimize scoring cuts 5. Remove all release paper per standard installation instructions and adhere to substrate using a square piece of flashing material (6" x 6" Minimum) 6. Fold as shown by arrows 7. Angle of corner may vary, adjust folding of the flashing accordingly to fit tight to corner 8. Mechanically fasten as necessary 1/2" DUROCK- 8" CMU WEATHER RESISITIVE BARRIER SEAL TOPS OF JOIc UNDER DECKING ED FLASHING (SEE DETAIL WP07) kSHING WEATHER RESISTIVE BARRIER SELF -ADHERED FLASHING EXTERIOR DOOR WITH DECK - SECTION A EXTERIOR SHEATHING 3/4"-l" BEAD OF CONSTR. ADHESIVE TO BE APPLIED UNDER - LA I ..... THRESHOLD OF DOOR AND RETURN UP JAMB 6". USE LIQUID NAIL BRAND OR EQUAL WEATHER PROOF CAULKING SECTION -A (SEE DETAIL SELF -ADHERED FLASHING Q 2 § I SEAL TOPS OF JOISTS UNDER DECKING 8 (SEE DETAIL WPO-1) SELF -ADHERED FLASHING EXTERIOR DOOR WITH DECK E AM Q 1'4" PER PLAN l'-O" PER PLAN 4" OR 8" CMU (PER SEAT DEPTH)­­--i FILL WITH GROUT Z SLOPED MUD BED 4 VINYL SHOWER PAN SL PE 4 SHOWER SEAT :�J SELF-ADHER SELF -ADHERED FLASHING OUTSIDE CORNER F_ < Lu > M Z Z 1 Z m Lu CL LU CL I-- 0 C/) Lu 0 LLI < LU Cn Lu 3: o U) WINDOW UNIT FLASHING REQUIREMENTS. DOOR ROUGH OPENING SLOPE 0.3 in: 12.0 in R703.1 General. Exterior walls shall provide the building with a weather -resistant exterior wall envelope. The exterior wall envelope shall 3/4"-1 "BEAD OF CONSTR. (0.6 cm: 30.5 cm) include flashing as described in Section R703.4. ADHESIVE TO BE APPLIED UNDER SELF -ADHERED FLASHING THRESHOLD OF DOOR AND RETURN UP JAMB 6". USE LIQUID EXTERIOR R703.1.1 Water resistance. The exterior wall envelope shall be designed and constructed in a manner that prevents the accumulation of water NAIL BRAND OR EQUAL WEATHER PROOF CAULKING CEMT. FIN. within the wall assembly by providing a water-resistant barrier behind the exterior cladding as required by Section R703.2 and a means of SELF -ADHERED FLASHING BUILDING PAPER draining to the exterior water that penetrates the exterior cladding. WIRE LATH R703.2 Water -resistive barrier. One layer of No. 15 asphalt felt, free from holes and breaks, complying with ASTM D226 for Type 1 felt or other SUBFLOOR a roved water -resistive barrier shall be a lied over studs or sheathin of all exterior alls N 15 as h lt f lt h ll b li d h i t ll pp pp g . p pp or z a y, with the upper layer lapped over the lower layer not less than 2 inches. Where joints occur, felt shall be lapped not less than 6 inches. Other approved materials shall be installed in accordance with the water -resistive barrier manufacturer's installation instructions. The No.15 asphalt RIM JOIST felt or other approved water -resistive barrier material shall be continuous to the top of walls and terminated at penetrations and building appendages in a manner to meet the requirements of the exterior wall envelope as described in Section R703. 1. R703.7.3 Water -resistive barriers Water -resistive barriers shall be installed as required in Section R703.2 and, where applied over wood -based A sheathing, shall include a water -resistive vapor -permeable barrier with a performance at least equivalent to two layers of Grade D paper. The A A V V individual layers shall be installed independently such that each layer provides a separate continuous plane and any flashing (installed in accordance with Section R703.4) intended to drain to the water -resistive barrier is directed between the layers. SELF -ADHERED FLASHING EMT. FINISH SILL] POTSHELF/ CHIMNEY SHOULDER Exception: Where the water -resistive barrier that is applied over wood -based sheathing has a water resistance Ai c equal to or greater than that of 60-minute Grade D paper and is separated from the stucco by an intervening, MECHANICALLY FASTEN IF RUBBERIZED RUBBERIZED ASPHALT substantially nonwater-absorbing layer or designed drainage space. NEEDED IN CORNERS ADHESIVE INSTALL SELF -ADHERED THROUGH SELF -ADHERED ASPHALT ADHESIVE FLASHING JAMB & HEAD R703.4 Flashing. Approved metal flashing, vinyl flashing, self -adhered membranes and mechanically attached flexible flashing shall be applied FLASHING, SEE FLASHING SELF -ADHERED FLASHING shingle -fashion or in accordance with the manufacturer's instructions. Metal flashing shall be corrosion resistant. Fluid -applied membranes FLANGED WINDOW (SEE DETAIL WP`01) used as flashing shall be applied in accordance with the manufacturer's instructions. All flashing shall be applied in a manner to prevent the SCORED entry of water into the wall cavity or penetration of water to the building structural framing components. RELEASE PAPER Self -adhered membranes used as flashing shall comply with AAMA 711. All exterior fenestration products shall be sealed at the juncture with (BEFORE FOLDING, SCORE SELF ADHERED FLASHING, RELEASE PAPER TO EXPOSE the building wall with a sealant complying with AAMA 800 or ASTM C920 Class 25 Grade NS or greater for proper joint expansion and EXT�ND A MINIMUM 6" ADHESIVE AS SHOWN) contraction, ASTMC1 281, AAMA 812, or other approved standard as appropriate for the type of sealant. Fluid -applied membranes used as VERTICALLY FROM BOTTOM OF flashing in exterior walls shall comply with AAMA 714. The flashing shall extend to the surface of the exterior wall finish. Approved flashings THRESHOLD shall be installed at the following locations: 1. 1. Exterior window and door openings. Flashing at exterior window and door openings shall extend to the surface of the exterior wall finish or to the water -resistive barrier complying with Section 703.2 for subsequent drainage. Mechanically attached flexible flashings shall comply with AAMA 712. Flashing at exterior window and door openings shall be installed in accordance with one or more of the 2 following: 5 1.1 The fenestration manufacturer's installation and flashing instructions, or for applications not addressed in the fenestration manufacturer's instructions, in accordance with the flashing manufacturer's instructions. Where flashing instructions or details are 4 I I not provided, pan flashing shall be installed at the sill of exterior window and door openings. Pan flashing shall be sealed or 6 sloped in such a manner as to direct water to the surface of the exterior wall finish or to the water resistive barrier for subsequent 7 drainage. Openings using pan flashing shall incorporate flashing or protection at the head and sides. 1.2 1.2. In accordance with the flashing design or method of a registered design professional. 1.3 1.3. In accordance with other approved methods. SELF -ADHERED FLASHING 1.4 In accordance with FMA/AAMA 100, FMA/ AAMA 200, FMA/WDMA 250, FMA/AAMA/ WDMA 300 or FMA/AAMAIWDMA 400. INSIDE CORNER 2.2.At the intersection of chimneys or other masonry construction with frame or stucco walls, with projecting lips on both sides under ISO AMN stucco copings. Ground 3.3.Under and at the ends of masonry, wood or metal copings and sills. 4.4. Continuously above all projecting wood trim. 5.5.Where exterior porches, decks or stairs attach to a wall or floor assembly of wood -frame construction. 6.6.At wall and roof intersections. I Water Resistant Barrier 7.7.At built-in Quitters. -LF-ADHERED FLASHING kTCH HERED FLASHING 2 4 5 FOUNDATION WEEP SCREED STRIP OF SAF DRAINAGE PLANE WRB BOND BREAK WRB SF LATH WRAP DP WRB ONTO THE VERTICAL SURFACE TO TOP OF FLANGE AS AN AIR BARRIER 3-1/2" INCH FLANGE THIS GAP IS A RESULT OF NATURAL SHRINKAGE. DO NOT SEAL. DRIP SCREED PLASTIC ACCESSORY SOFFIT/CANTI LEVER LEGEND SELF ADHERED FLASHING (SAF) DRAINAGE PLANE (DP) WEATHER RESISTANT BARRIER (WRB) BOND BREAK WEATHER RESISTANT BARRIER SELF FURRING (SF) LATH PLASTER ACCESSORY SHEATHING, 'OSB', PLYWOOD, DENSGLASS ER STOP kST NTINUOUS BACKER ROD EALANT vIENTITIOUS FINISH Lath Sheathing Stucco RUCTURAL FRAMING RUCTURAL SHEATHING RIP OF SAF AINAGE PLANE WRB ND BREAK WRB LATH Cement Plaster in accordance with ASTMC926 over wood 2nd floor THESE DETAILS ARE GENERIC AND MEANT TO SHOW GENERAL FLASHING AND WATERPROOFING METHODS TO BE USED. Cement Plaster er block ov 1 st floor 7/8" Cement Plaster in accordance with ASTMC926 Felt backed metal lathe in accordance with ASTMC 1063 Building Paper -7/16" O.S.B. sheathing - Metal Flashing Weep Screed Installed As Per Manufact. Specs. Maintain Bottom of Weep Screed 1 1/2" to 2" Above Roof Sheathing LIZ Note: The building paper and metal lath must be installed over the top of the weep screed. /0"N WEEP SCREED DETAIL SCALE: NOT TO SCALE 7/8" Cement Plaster in accordance with ASTMC926 Felt backed metal lathe in accordance with ASTMC 1063 Building Paper 7/16" O.S.B. sheathing Stampede or similar cauk bottom joint only Weep Screed Installed As Per Manufact. Specs. 1/2" Cementitious Decorative Finish All inside and outside corner will need to be miter cut and caulked all butt joints need to becaulked using Stampede or sim. caulk for all C14 To the best of the Engineer's knowledge, information and beflaf, the structural plans and specifications contained within these drawings comply with the 2020 Florida Building Code - Residential 7th Edition. Engineers signature and sea] is only for the structural engineering portions of the drawing pages bearing Engineers signature and seal. 4 -,ct E Q 8 co C-, 1.31 W 5 ID 0 1 20 00 :1 it it- W 0 0 '0 U) ". Z Z;? - LU U_ 0 M U_ U_ CL W Z _J - ;; :� -. - - 0 � 5 1 8. C�4 (D 0 P M y _J W < Z LLW 00 0 to Z _J Ln 0 < 0 Z 0 g < V) C1 CIO LU U 0 LU g - U) U a - 3 E C) W < cl� co 0� 4 U_ C6 E CL 0 Z E CU CL �O Z CD, E C,4 < Z W Z 0 < 2 wo 10 Z U3 Z I , W U) �5 Im < 1Z 0 CL Z. W XC CZ) to 8 .0 C) U) � 4 0 (0 0 00 0 > (D > 0 C) 0 (0 C: 0 r E C\l 0 U-) TZ CN U') M 0) U-) oo CN CN Cn E E N CV) .. 0 Z Z E c) U) 0 �5 r_ M E 0 0 'a < JOB NO: 21-2029 SCALE AS NOTED SHEET NO. W P I , � I I tog, � I ilimVw,l I - Mounting Brackets (10 Gauqe� 4-112'x 4- 1 .-*2'x 2-12" bKk Cross Support See Anchor Schedule (May be cut to W) Right Bracket (16 Gauge) Bolts 1/2" Dia. A325 Galv. (Typ') 414 Self-Dril ling Screws A/C Ill Bottom Edge HurricaneStralp Washers (Typical: 3 in front) Front Cross Support Self -Locking Nuts (May be cut to W) Left Bradclet 0 6 Ga ug.e) If 14 Sell"I Ing Sicrevirs Thru Brackets & BackCross Support Into AIC Unit Bottom Side (Typic& 3 each side for hurricane use) -4-d. thatialliet., W enith _h Huchrecuatc -Au atral- =z"llevallow upon "idaw fiw *a apply) Florida Department of Business & Professional Regulation Building Codes and Standards Product Approval Application Detall Page I al 1", 21 2& Enift car 292 20 7vp. veral Manufacturer Coal anghnixer a U-- Vaidatted By Vaildellid aubtrill FRC Appir-al ateacts Affirmul 2020 $rmln Verri Products. Inc MichatilGraham Hermes F himeto PE� Looks BMd" P E. 12MC42a2O 12/116=20 I M&7020 Apprell ca"'al sh"'I'll Component, flrr� 4414368 PF,13778 (334,300-1800 Subcategory; PI ch Introoluoixil it triptirmart-tcom Neir, TocibroI Compiler— "find E-luefixon Report from. Rord. Regavlad Architect .1. Licaread I'll fuitsm-nanickwa Pr.rattilonal Eigh-, 2ifil or 1420111, Product Dixecriatfin, Guilty Assurance Apgronddloruso In Hill ApproveldirctrUse Outside NvKZ know Reenacted Dealign P-, 1 ==-Ibl 01540-110 F.hctt. F] vi"dialron WIN 1111`111�12' Y. Y. WA '100 100 2 Strait Model 01540-511 = Due Function Flood tinct Venibbilloon Vent 2/31 f2 20 Y. Y. NJA " 0I 3 Smart MccNIS1540-120 dFlopti 2f , n020 Y- Yea NIA '1 .100 4 SmartVand M ISI140-521 �nsula -lated Food Vant I 2f If2020 Yet, Y. N .10I 5 murt Mocal M 540-524 15&qp1,G.ra9nD-FI.odVed 1 W3V2D2 Y. Y. N WA 6 S-Avent Madial #1541 , MR Insulated Flood! Vent I Mi f2020 yes, Y. N/A .10D -100 7 SmanVart Mocial Ari 14s&qI Gorilla Data il Vtat , 213 , /2020 yea, Y. 141A YA Flo India Dope rtme I of Business & Professional Regulation Building Codes and Standards Product Approval Application Detall page 1 .41 IM41.021 2991 1111111111 292 go Dabilixtridim 2111 TV" venetian lianr.A.- Contact EQln- 11, 11-conneei V.11darxid By Validated Submitted F11C Apploleal AW strituat R.'Asnon 2020 Drexel Metals 1. Jason Shumalu, Zachary R Prest LOCKA SoaI%lon P E Ofil10I 011,09V2020 oano(2020 IDA3=0 Appr..d Cateetery: Ropling f5O2) 303-1511 PF-74021 (334,300-111100 thuditalegorl Mftl Rooling ishurraterildrentmat Compilariev Allatlicid, E%aluation Rarpod from Foride Registered Architect ore Licensed Mince ordere.ital Fratineer ILi"78714tBP-d.ft gat Iturl or Name Quall Asateral Pnedud Description comw Expiration ode ApprigIno tor Use Audormand in NVHZ outside, for I know posim N1%Q gqslstam =Morring systions DMC 10ONS. DMIC 15083, 1 175S, OMC 200&t 12131=25 Y. No NIA +00410 011I Flo ridis De pa ament of Business & Professional R eguls flon Building Codes and Ste recta rds, Product Approval Application Detail P.D. I of 3 117/2021 It 21L. wt Data Pending TX22 Verificin MnufW,- Conted VNdtd Ev Vallichatud Submitted F6C Azonarral Apal Stat_ R-a- 20`20 Thermet-T.Corporala. Sierra Jearperson Lyndon F Schmid. P. E. Ryon J. II P.E. 07123n020 07M ZQII 07r-02020 1 Wl 3M20 AppI cat.gloryt acerar 0- (800) W-7624 PE-43409 ($13,761 subcategory: Swinging Extonot Door Aaaernict 'o Compliam.. 1110.1told: Evaluation Report torm a m Florida Registered Architect or a _k­ III Florida Euam[LgLnRam Proreall cial Entimear .11111" 11==ff 11 Name Product Deurbzo QualltilAssurancit Aparoyarg for Use Approntild In KMZ outside for Use Impact Resistant Derson PL"SUN 1 al and Smccth-Str hicarral 64#39�8 &quottimpeci9quot. Opawe 12P31 R021 No Yea Y., WA Composite Edge I'llnergettIe Single Door thentingrOutswing : X codgurarsul 2 b Therm.-Tru Fillber-Cimll and Smootti-Slar Nominal 6&439,111 &NdAmpact4liquot. Opal we 12/31 (1 No Y. Y. NIA Comporelta Edge Ft, -gil... Sungle Door al "Il XO' OX or OXo configurabons) 3 Theaml Filper-Chl.lo and S-th-Stal Nomir.163935i'li liquarricaptutuquoir Ool 1VW20211 No Y- Yes IWA Composite Edge FIberon-, D.Ipla Door -.ft or ,.,,th.t Sidelines iin­a(CI XX or OXXC configurallons 4 d. Thent-Tru Filbor-Classic and Smoolli-Star "..he 88"'l &I I.P.-tiliquot. Ope We 12/31fMI No Y. Yes NVA Composite Edge Footnote, Single Door im-9noutt-ing X onnnWrliboh, 5 a Thrimet-Tru Fbar-Classic and Smooth -Star N-h,.l luitil 11"I Impact4upt. Ope, que 12/31 �20211 No Y as Y. WA Composite Edge Fibergles, Single Door with Su'dialitoc"tur-hanDut"'Ang XO Oxoil 6 f "Iternal Flbw-Cll and Smooth -Star Will 84"Ill Opecul, 1261,2021 No Yes, Y. N?A Composite Edge Fiboraties Double Door -�* or without Sidelters (InswingrOunnering XX v OXX0 oonfiguutbon ) 7 g IrramI FlIber-Cleasic and Smoom-Ser NortunalaU39.6 GaI imi'2021 No Y. Y NIA Composite Edge Fiberalles Single Door itraraing'Cuta-Ing, X _11gumbon! h Th­*I Fibll,-Claei. and Srrocrm_�.r Nominal SAI ticculdtlaud3cuut: Geared lminoI No Y. Y. N/A Composite Ecill Fical... Single Door wim ScI.R.C.) (In-ingrOut-ing: XO 0 X or OXO config.retion.) 1, Thermil Floer-Canso and Smooth-Suar Normnal 6&03' 8 &WctImp*c1&quol Glued 12131,2021 No Y. Yes NIA Compoette Edge Fibaphies Dol Door with or 'rmoJI131,11 talthereingtounatingimpil -Va." :%) WR 12 1 rhearra-Tru Fl­Cemo and smooth-Ster Machine! 8&0139�0 SquWauxed4cl GaI l2nift2il No Year Y. NIA Composite Ed" Flicargue Dwole Door with or "ftcut sidebill itnewnwoull-4hic XX or OXXG onarlig.,abons) Florida Department of Business & Professional Regulation Building Codes and Standards Product Approval Application Detall P.9 I of 1 16=1 February 12, 2021 PRODUCT APPROVAL SPECIFICATION SHEET (2021) As required by Florida Statute 553.842 and Florida Administrative Code 913-72, please prWde the infbrmation and approval numbers on the building components listed below if they will be utilized on the construction project for which you are applying lbr a CategoryiSubeategory ManugMturer Product Description Approval Number(s) Test Pressures Expel. Date 1. EXTERIOR DOORS IThermaTru 1 1 I A. SWINGING Fiber -Classic and Sm ooth-Star (NON -IMPACT) FL20461.1 +67.01-67.0 psf 12/31/2021 ThermaTru Fiber -Classic and Sm ooth-Star (IMPACT) FL20468 +67.01-67.0 psf 12/31/2021 ThermaTru Fiber -Classic and Smooth -Star (IMPACT) FL20470 +80.01-80.0 psf 12/31/2021 B. SLIDING MI Windows and Doors Series 420 FL1 5332. 1 - F Ll 5332.5 +40.0140.0 psf 12/31/2024 PGT Series 5570 FL251.9 4/14/2021 C. SEC11ONAL Wayne -Dalton Series 8000/8100/8200 #1105 (8X7) FL8248.3 +31.0/-35.0 12/31/2023 Wayne -Dalton Series 8000/8100/8200 #1123 (16X7) FL8248. 10 +30.0/-33.5 12/31/2023 D. METAL LOUVERED DRS Curries Division of AADG, Inc 607,707,727,747,and 847 Single & Pairs of Doors FL11537.1 N/A (see inst sht) 12/31/2025 2. WINDOWS A. SINGLE HUNG MI Windows and Doors Series 185 FL1 7499.2 +60.01-60.0 psf 10/8/2023 PGT Series 5500 FL239.2 N/A 7/30/2025 B. HORIZONTAL SLIDER MI Windows and Doors Series 188 FL15351.1 +55.0/-55.0 psf 2/16/2024 C. FIXED MI Windows and Doors Series 185 FL15349.1 +60.0/-60.0 psf 4/3/2023 PGT Series 5520 FL243.5 N/A 4/30/2025 D. MULLION MI Windows and Doors Series 5764 FL1 5353.2 N/A 12/31/2024 PGT Series 5500 FL261.1 N/A 5/26/2026 E. OTHER 3. PANEL WALL James Hardie Building Prod. Cemplank Lap Siding and HardiePlank Lap Siding FL1 3192.1 - F Ll 3192.2 A. SIDING N/A 12/31/2023 B. SOFFITS Alside Solid and Vented SoMt FL1 5272.1 - F Ll 5272.2 +75.01-75.0 psf 12/31/2021 C. OTHER 4. ROOFING PRODUCTS A. ASPHALT SHINGLES GAF 3 Tab, Dimensional FL10124.1 N/A 12/16/2022 B. UNDERLAYMENTS Tam ko 151b Felt Underlayment FL12328 N/A 10/18/2021 C. ROOFING FASTENERS NOTUSED D. ROOF VENTILATORS Thompson Arch Metal Comp. 1171orida Off Ridge Vents FL16918.1 - FL16918.4 N/A 9/9/2026 Metal Products, Inc Vent RV10 FL21580.3 N/A 12/31/2024 Lomanco, Inc DA4 Exall Vent FL1 7202.1 +97.5/-97.5 psf 12/10/2025 E. ROOFING TILES Boral Tile Villa 900 FL7849.27 - FL7849.28 N/A 12131/2025 Boral Tile Saxony 900 FL7849.16 - FL7849.20 N/A 12/31/2025 F. METAL ROOF Drexel Metals, Inc. DMC 10ONS, DMC 150SS, DMC 175S, DMC 200S, DMC 5V FL17679.1 +0/-180 12/31/2025 5. SHUTTERS A. STORM PANELS Global Protection Products Galvanized Steel Storm Panels FL1 5076.1 - FL1 5076.2 N/A 12/31/2021 All American Shutters & Glass Galvanized Steel Storm Panels FL1 7869.1 N/A 12/31/2021 6. STRUCTURAL COMPONENTS A . WOOD CONNECTORS/ ANCHORS USP Structural Conn. see chart Simpson Strong -Tie see chart B. TRUSS PLATES ITW Building Components Alpine Truss Plates FL1999.1 - FL1999.4 N/A 12131/2024 MiTek Industries, Inc. Truss Plates FL2197.1 - FL2197.5 N/A 6/30/2021 C. ENGINEERED LUMBER Weyerhaeuser Rim Board, LVL, PSL, LSL FL6527.1 - FL6527.5 N/A 3/31/2021 D. MATERIAL Cast -Crete Corp. High Strength Concrete Lintels FL1 58.1 N/A 5/21/20222 :Commercial Concrete Products, Inc. High Strength Concrete Lintels FL1 774 N/A 5/25/2024 The products listed below did not demonstrate product approyal at plan re%Aew. I understand that at the time of inspection of these products, the lbilowing initirmation must be available to the inspector on the jobsite; 1) copy of the product approval, 2) APPLICANT SIGNATURE DATE Florida Department of Business & Professional Regulation P.O. 1 arl, Building Codes arid Standards larlw Product Approval Application Detail 92k Sal or JAU 2ft Dote Pindria Gas Mal vanultal Id-riectimor Coal Encil- & Li- validated 9, validated Submitted FOC A -,I A�,,d ama R.,4ai- 2020 Thermal corporation, Ill J.M- Lynclon F Schrind, P E. Ryan J King, P G 07r=m OT/12/2020 07`12W2020 1011312020 Apv-d canagely, exterior Oppre (9001843-7628 PE-43409 013) 767-6555 Subcategory: &*9mg Exterior Door Asearritale. suithapentionothermadru cc Compliance NOmd Exaluailon Raoul tom a in Floret a Regttred Archil or a L w. d Florida P'tirearacced Engineer FLA2§tM4t3 Product, Apormhad for Ul Amoyed for Vu knwl Denslon al Produm Modal. Nearrillew or N� 16M In HVI curbilde lit"Kant ler 1 a. Thenme-Tru Fib*�Classlc and Smooth -Star Nominal 6039.8 "ot;Ihorectilquot Opaque 1213112021 Yes Yea Yea WA Corrippaire Edge Flbol Since Door (linealngOulselhit; X contiturell.) 2 K Thermal Fib-Chisaic end linnooth-St. Norninal 61111 Opaque, i2131=21 Yen, Y.. Yer; WA Con"te, Edge Fbvi;%" ShIga Doorwith &ddkt�S) (Ine"ing"Ou"'Wrig: XO. Ox or OX0 conliguralorai 3 c Therml Fiber-Chert- &I Stirooll Norrinel 09*39.8 Opaque 12*112021 Yea Yea yea WA Compoeta Edge Fiberglass Double Doorwith or AthoutSidielph' (traxtingrOutlaing: XX or OXXC, configurational 4 d. TharmaI Fib-Oaasic end Strouth-Star O.P.08,cluct, oplaqu. 12/3112021 Yea Yet, Y" WA Composite Edge Rbargass Shole Door (In-rignOut-Ing. X.-Illituerbom 5 1 ThernwTirit Abvir-Clasec and sincom-Suat Nominal aillill alled:Irribectilti Opaque IM112021 Y. Yea yes; WA Composite, Edge FIblergleas Single Door win Bdald.(.) (minvireCul-hil XO OX or OXO "'figunitiontu 6 f Tlr�-Tru Fber-Classic and Smoolnftr Non"Imill 88011 alcupt:11"I'llitutiquot Ool 12J3112021 Yes Y.S Yes WA Composite, Edge Fiberglass Double, Door YrIth or .0thout Spirits �Ins-Ang,'Culaxfing; XX or OXKO configurations) 7 c. Thermal Fluar-Classic and Smooth-Slar Nominal 60N:8 OicitAnpacisq'ot Glazed 12`3112021 Yea Yea Yea NVA Composite Edge Fiberglass single Dcor ths.ingouta.migi; X,aniguration) 8 h. Therme,Tru Rbor-Cliell shot Smoom-Sta, Nominal 69439',g Gilized i2J31)2021 Y" Yea Yea WA Composite Edge Fiber" Single Dourvith SdOlmsi (Imp,InoQias�n9; XO OX or OXO _11g.r.tion.? 9 1 ThemI Filer-Itissi. and Surnallistar Norrined 09439.8 &wokipectil Glued 1213112021 Y. Y.. Ye, WA Composite Ecig. Fiberglass Double Door -AM or 'Ithourt tsditiblet (risx6rigrOurtairnit: XX or OXXO configurations, 10 J Therru-Tru Filb-CitsI Sexxoth,18t. Norrinal 8&A39,0 t6quat:Impectiquot. owed 12131r2021 Y. yea Y. WA Composite Edge FlIberght. &.We Door (haronlioulwing; X conliguretion) 11 l Therninei-Tru Floer-Cleasc and Smoothl Noll again Oliquot:"clarquot owed i2(31r2D21 Yes yc,' Y. I Computer Edge Fibergal State Door with Scialkine) fl-IneOut-ing. XO. OX or OXO configuration.) 12 1 ThenI and Sprecer-St. Nominal 8"39.0 Glazed QM112021 Y. Yes 1. WA Corporate Edge Filial Doulcier Doorwitri or .I,whout Sidelool, orsaingrout-Ing; XX or OXxo configuration.) 13 in Theril Ftbar.Clastrac and Smcamaintr Nail 64939 A 8,quat:11impectiquot Opaque 12/31n021 Yes Y. Y. WA Composite Edge Rbragh­ Surig. Door in ii,ceiat'NorrimpectI sidettiI (InsaringlOurphl XO. OX or OXO 14 n. Thermal Rb.,�Cunaxcranxd Smooth -St., Norind B&AII &qee*;"d&ql Clude 12/311201 Y. Y_ Y., WA Composite Edge Fibixglass Double Dorerwril, &I Sids4lies onsaingrOuWng: OW configural 15 Th.mal Fultai,Qatai, and Shnooth-St., Nommuld 6$*1 &Cpud;khppekMpL opal i2J3112021 Y. Y. Year WA Conneceft.Edg.tribiaglituSingi D--,kh (InsiringrOultial XO, OX or OXG comigurabothl 16 p. Th.-Tru Fiblu-Cleal-nedl arroom-S", Norninal all &WdArcadliquot, Opaque 12131r2021 Y. Y- Y., WA Comporaft Edge Fibergirela Deatter Door aith &q.d;N-Impad4cvof Sidelt. (InsxmgOxusihg. OXXO contillpemati 17 q. Thel-Tru Filter-Oil.l. shot Strocith-Stbur Nominal Siluill Opaque 12(3112021 Y. yea, No WA Conniucaft. Edge Mbergl Sl Door (InsnimiltOuriwing; X "prIgurshol 18 r Thermle-Tru Fbar-CluI and Srhoollh-St., Nammad 6&*M A 8,quaLN-Imprictliquot; Opq.. IT31/21021 Yea Yea No WA Compixert. Edge Fiberglass Qrol. Do. Ith Sidoldl thaxnIngOutinyrit, XO. OX a OXO colifigurationsl is a Therma-Tru Floar-Citilanc and Smoodil N orni n at 6 MM " "ot, Non-firipa" qua; Opaque 1213112021 Yes Y_ No WA Carotene Edge Flbergl­ Double Dooraith or Mm out Sidellbes (InseadinglOulull rg: XX or OXXO confil lons] 20 L Th-.Tu folar-Cl.,sic and Srhocm�Sua r N-m -18&939.0 Opaque lV3112021 Y. Y. No WA Composite Edge I'lluere.. Single Door C InexxingtOurt-Z. X tonlisimation) 71 u. Tha Imp. Tru Fiber-Cansic aW Sm oom.4ft, N arrin al 88" -.0 clud; Cpaq.. 1=1n(121 Y. yes No NIA Corporate Edge Fiberglass Singe Doorwith acted I �) ilmseingOul Who; XO. OX or OXO configunations) 22 v. Themel Fibet-Clasec and Smooth-Sper Nonlrad 8"39.10 Opaque 120112021 Yes Yea NO NIA Comiticel Edge Fiberglass Double Doorwth or .b out sh"alt. (Inwhorouhirwril. XX or OXXID configurilt"'I" 23 Th-Tru Rbee--4sac and SmocalShir l4cinrinal 09#39,8 ilroud:114-InVictlittruct; Glazed 121 Y. Y.. Nlo WA Composite Edge Inbrada- Smile Door , In-Ing(otsarmil X .-Iiiratom 24 x. Itancl Fiber-Classlo and $moct-Star Nominal 5"1 Glued 12`3112021 Y. Yes No WA Compoeft, Edge Fibitrorrea 0.91. Door with Social (IminxingiQuionfing: XO. OX or OXO configunalone) 25 y Therma-Tru Foor-Chisil and Smooth -Star Nominal 66#39.8 Glazerd 12131(2021 Y. Y. NO NIA Compul Edge Rbargla. Double Door atth or Y41rcut Sidezee 0meMrWOut9Wng, XX a OXX0 configurational 26 z. Therml Floar-Clasida lend Smoddr-Star Nominal 88"g "M�N-IrT1pcnl Olazed 1=112021 Y. Y.9 No WA Compoill Edge Fiberglass Single Door X c�lgumtm) 77 ce Thatine-Tru Fiber -Classic and Stnooth-Slar N."Imad 41943CO &QUaNcri-Iripactill Glazed 12131/2021 Y.9 Yea No WA, Composite Edge Fiberglass Single D=Vkh 5ftWI) fl-winginOuturarrit. XO, OXor OXO conligunational 28 rh-Jru Fiber-Olissic and Sm..M.St., Norrinal II&MO QW12021 Y. Y. No WA Corporate Edge Fiberglass Double Doorwith witch put adelites (InixinnilrOuta,,ing, XX or OZ. configuration.) Florida Department of Business & Professional Regulation PaII &2 Building Codes and Standards Product Approval Application Detall Q1ft EntK� car 21111 Data Faced- A& MM Verel Omnfaft- Contact In,],,& License VAdMid 0, vall" Stibrilted FOC Approval Amarl R.Iiaxpr 2020 ThermaJwCarperaticI R-AW.- Lyrd" F S""m P E Ryan J King. P E 1OMN2020 07112n020 07r4W020 1GM31M20 Appr"d Caltaill Extror Door. (800) 8,34628 PE-43409 (8133 767-6655 SubC.Nearr- Swinging Exterior Door Assalmollia slatipersonothernatruco compliance WAthD&. SxuJOI Report torn . m Flonda Regill't"red Architect we Licanted Florida Prof. sectral Engn.. PLA20M-IgPrad,- Quallity Alineurancia Aloarcheatincerthi, Aicitercl for Use N.� Dandon Nismear I No- leodul Description Cgotul�t=.Qiiij jaj= Oubdid, HPAU R,dt" I Fiber -Classic and Smooth-Shar Nominal 68ul &quorNon-lumbacNicluct. Opaque No YIa No N/A Composite Edge I'llte-glithire Single Dopt (InarincrOutstaing; X configuration) C&k I= variation R-.i- 2020 Mt Wind-iind Door. Category sIderor 0- SeebCareattiln ending Exhar Ow Assemblies CornpIlarce Metal Enustion Report tom a Flori Registered ArchR.0 cra Licareed Florida Pirpnernsionill EnSim.. N'U'MIS W'" UMM"l 2 SERIES 420ALUMINUM SGO 3 SERIES 420ALUMINUM SGO REINFORCED 4 SERIES 420ALUMINUM SOID REINFORCED 5 SERIES 420ALUMINUM SGO REINFORCED 9mb UctLz 2a 20 Data lasandiree so, W-1 299 ZUg` Version &UnufKturw cmtact validated By Vidid&M submitted PlIC AWMVW Aboroved @tans _A1211. version Illarturfacturair ReI 2020 PIGTInd-I Jene R-AA Misiml-Dild. SCCO - CER Ifiar-i-Dd.115000-VAL 11/191 101261 1 V24r"20 AWO-A ReAsion 2020 Winal a-D.R., a dWsion or Overhead Door category; Exithip, D­ J941) 4811 (7116) 315-25K Corporation Subcategory; Sitting Extrnar Door Aninniblas pos-ld"nell... Category: Exterior Door, compliance MthoO: C"cabon Mark or Ual ulacalactchil sections] Et- Door Asixamblers Corripilance 1111.1111did! Elaituatlor, Report ft" I FLOMAMPtad..h Flodds RegisterindArchdrector a Licensed ,.do. Professional Engineer Quality Assurande, Acorte"Aforlull Amroved for Usa acted Health, or Name lanaltict D.-Ital Ccirill Data "Vwz Duteld, Hl Iterehatent P-, 0 70 (Larger Milial fiall Vir,,4 Sitting Glune Door Year Y" Yea WA =ll odl liumther or� Kim 01MI200411105 10 8000,111OW200#1123 Florl& Department of Business & Professional Regulation Building Codes a red Sta riclairds Product Approval Application Detail Page i of 2 1 6=1 Intity or a" 2" 13.1. P,,I- 20 validated 0, submitted F9C Approval A,- ALIWL Eir-1911- Lure Robeft Lomee Sternan M I Pr 10)(3812021) ioxI 10AW1020 12,1512020 App-I (717) 365" 330 FI 4 (7171317-6454 binfling.'armtrd.cohn, Prodeact D-kffi,� SERIES 420 ALUMINUM SGID OXO Qualft A,,,- 12011121024 A-,-d for Us, A-,,d I, HVKz outside No to, the HVNZ Y. Imixed fl-khant No Dealon preseu. N/A 145-31"quotulWpual: NON -REINFORCED SERIES 420 ALUMINUMSGD OX XO' XX 1W1n024 No yea No N/A 96&qu.t;x80&cucc NO�REINFORCED SERIES 420 ALUMINUM SGO REINFORCED OXO 12/311=24 No yee No I'l 145�314&quotx95".ct, SERIES 420 ALUMINU M SOD REINFORCED OX 125112024 No Yes No N/A XO. )D(Wquot:x96&qr"' SERIES 420 ALUMINUM SOD REINFORCED X" 12MV2024 No yee No WA 143ticeia;x9as'licuol Floril Department of Business & Professional Regulation Bui Idi ng Codes and Stands rds Product Approval Application Dettall contact Engineer & uctursel Dartlyn. K-I,h John r. SC21M (W) 763-8121 PE-51737 dconishilit�yn'taruch c m laroduct Description M#315. Max *il 14&039: Max, height GII inaitable in top or section 1 611,038, MU Width, 1481 Mm helight. Glang 6�14bixl In top or hlemnedlide, section. Page 1 (2 I&M1 291 DO Data Pendinto mt Valldst,ld By VAIldlatend SLtENted FDIC Apprenral Approved am Jalmair P� Annenct, PS 10/12M20 DMIV2020 10111 1211512020 APPI (904) 821-5200 Quality Approved for U, hourciveld for Use Impact Dardan In HVHZ ouladdir Resistant lentersure 2131Q02: No Ye: Y. 131001-35 00 213 1 r202 No Y. Y. -3Q.001-33.50 (D -Cu > C) =3 CL 0 0 a) CL CU -0 L_ CL- Cn CD -0 CU 0 -cu -0 Fn �M = 0 2 CU 0 CU 0 CU > (n .- Cn E -0 (D E " 42 2 ca- cuu) -0 C/) 0- Z Z W mi cn E C_ (n co CU > 0 > L CL 0 CL < 0 0 CU cn < CIO LU __J SHEET NO. PA 1.0. I I'll I I III- .. Per , I I —1 —1 "111, 1 U, 111 11 !mqi Florida Depertment of Business & Professional Regulation Page I oil I Florida [)apartment of Business & Professional Regulation Page I f2 Florida Department of Business & Professional Regulation Page I art Florida Dope rtmW of Business & Professional Regulation Paget oil Building Codes and Standards 1 &2021 Building Codes and Standards 1 Build rig Codes arid Standards Building Codes " Standards Product Approval Application Detail Product Approval Application Detail Product Approval Application Detail Product Approval Application Detail Ml.m QQI V— NMI Wo.161111ho I !I 'I I !!,III tn*v or cortaot, find-,& Lk—, VAdgd 81 I NIP! 11% 1 I I VAL ]MI YARdmid likerafflad Dow, Istaging FRC AguraVal Ausimervad Version RUhfW,, Entity w Carried Emaki—A.11— Veldialoll 8, Cat Panama Submitted FBC A-havol Agona-d Q& MM version anutw,ta !!1 feallt. CQWad 0,,Mtm & UcMwinIe Vagiftid By am 2" Voilddtd Submitted Door P-d— am P&C AWFOVal Approved awn mm varthan NW,4,=- Entity or Contact taggAKAUmm wa� m 21k Dot DK* Persolno YWLWAtd Submitted LIL&MG" A,--d Re,~ 2020 Curres Clylision of AADG, I.. CalloW. Exterior DoNs "Catoprr. Exterior Dox Components Carritillarist Method, Cwtftffhm Nkrk oi� LWhg Tw Rafty UL LLC Troy Bishop, P.E� �&I 494-2613 f954)947-06110 am. tiffirya—Mmy— 12MV2020 12101r:2020 1212V2020 Applosed RaMeM ZD20 hill Wndmswd Dome cattrow. wndvs "LloCamilorli Birds Hung orriollarre, Method: Cortitod. Mork or Lisbng Breht shimor AnWm Antiftedural Steven I U60 PE (TIT)361,3311 M—fied.—A—WIN (717) 311-6454 oubmilaternharo'corm Quotas A'sares- IIJ1712D20 11117/2020 ANnormul fist the, Auor .. d for the 11127r2020 ahead APPI parean Affirmation 2020 P(IT Industries Catisgaril: Wind—, SubCaftoorr. single Hung cei arshe M�ad: C ardlimuce Mark w UI Jan. R—.W ilboral-Daider SCC0- CER lillarri-Di SCCO - VAL (941)4N-0109 (786) 315-261011 ji-owskillitiogilindusides.t; om ilMi?D20 i1P5r202Q 1 Ili MAX Appro�d RI 20M fill WrI end Door, calergidar. what" 3ulaCattegorf. Hateomel Sid. Compiliari Method Cwflffcwgw 11I a Lisung BrentS10111.0, Amer— Archke,otural St— K UrIch, Pr (717) 365-33DO llhhurft�turai Association f?17)31r-5454 b'NkUaQ.1md_ 10MV2020 10manom 10,19=20 Appecx,ml FL#Iua7lu Product, 1w - In HYHZ 0"dis Ming Resistant Prawturat FLOTsm4teptodut" Quality Amr� AparoNedforksy Anoro"d for Use Impact Dedon 2 185 SH 52.72 FINFlares, Feres, IGI Single Hung IDA38,2023 NO Yes NA, �60[40 A,— Anoothad for U, A—cmad f. Us. ligaila peeks, QUWMV Assuranot Anorosedfor use Antroyed fm Un knmt Dardon SAIL9 in Hui ould" wdw Resistant P I wou - Leirnirmhad Glass aw BE* Pro*id Vestriouthri Cpruad EmiallmDat in HVICE OLM& MVKZ Roewmt p�m canbnad EkAh� D" I, HVII Quit0do H`VMZ assistant larsusturts 1 607, 70T, ?V, 747.757.777 end 547 Single and Pairs al Fl. sh. GI.W. and L—wed ashilk, mul pairs of iwla(125 yes yes Yes WA 2 8145500 (Large whole "Pod) Vinyl %"Is Hung Wndw 07Mr-1025 Ifes Yes yse NJA HS 1116 Fln and FI Frame 73.02 nsulaml Glass 02118)2024 N. Y. No -M-53 Doors III metal dcons, Florida Dope itrinant of Business & Professional Regulation PINK I or2 Florida Department of Business & Professional Regulation Page I &I Florida Department of Business & Professional ReguistiI Pop I (I Florida Deportment of Business & Professional Regulation Pq. I of I Building Codes and Standards I FV.wl Building Codes and Standards 16=1 Building Codes and Standards I&MI Building Codes and Standards 115=1 Product Approval Application Detail Product Approval Application Detail Product Approval Application Detail Product Approval Application Detall ____ .QM ___ ___ — i I I I � 111 � '' 1111! 1111 111 KIM! 1111 !;, 111 I I I ;I - — - — V — -_ - --- - - Entry or gat 20 I - - - Dft P"Xlm MEOW AD --- Ca& Eni w Data Fortall— 20 rdo 11111111101 lintor 11 ill I Ili 1 1 , 1111iiiiiiii i 2" 2da 1 11 od, Pmd- Etft ar- 2" 2" Data feemblina 292 im V,,V— N,,uftt,— Conled Submitted FBCAEara%qW A,—,d SAIrL vession manufwwrw C.*.d Endow & 111ohns, VIiddd W Vaiddiall &JEIW FIBC Awmall Aggrurvvid VW- co"doel Vid,,d a, VA",d Stibrafted F&C Awroyal A,,,,d VNI mmurwtuw corstact - - _.. 91 Valifted By SL&Mlltd FISC Awroyal Aparoyed am RI 2020 111 Whoi— and DNI Category, Wookhet; $LibC&t*Vfr. Axed BrandIstimper �Mrl­Armlthsduftl Shemn K LI PE t717) 385-33M Minf.Mrars A —hart- (717)317-8454 bsulinge.Wd— 1117=020 1112=020 1112am2o Appro-d Afflonsift 2D20 PGT Mckistrass colegai Wind—s SubCatagair. Fired Jam. R�� Nwhill-Dade RCCO - CER h%mI 131 -VAL (9-4114WOJOD (786) 315-25M InoBmidepiltindusalesto 1 IM)2D20 1105n)20 11111r2020 Approed R-- 2020 AR Whd­s and Doorm Cidegant, Whd-, gbCAt.WF. W.O.. amastflinger Luis R Lomas. PE St- kt WIN. Pr (717) 365-3300 PE-62514 (717) 317-8454 blittingthillithii Ims*M 1010I 10AW020 12M5i%20 App—d AMmetion 2D20 PGT Inwalros Category: wr� SLOCalthouthry: V.111on. J., R.%..W lAant-Daw 61 CER Mlans-Dade BCCO VAL (941) 486-0100 (786) 315-25N Jinbectimidillipiltindustri 11M5M20 1110512020 11111=0 Appr"d Complinn. OwhPt Carlifiimon NO&* or Liating C"Il�Ndbod! Cortireali Man, m Lftling Compiler" Mothod, Entuartim 1`14port tom a Compiler- MM.A: Ciettlesdion Me* et Using Ne Fl.d& Registered Arthlto�t .. U—sed Florida FLO'lS&6"14 Flpdmd. Queelft. A-- Arshanowdfortlaa, pirdeasi-al agi... PrAdutt model. "UmbK "am ProdukI Deetalptho ALILtttdlgLau In RVKZ out" HVHZ xa= it4smKlt ggwm 121A ChAK� A,— Pdd Domflation AmmayadfatrUme A-,—,df,U, In HVK outside WDad Ratimord 229an P—ns Ilia Product Model. Mumbw or New Qu&ft A,,� Product Dwriallon CorlxmLmAradlmom ANNovied for Usts Abounded for thus it] NVHI Oulaildle ftoad nodKm Dersion p�m 1 185 Pw 73.72finsul.t.dGJas. 04AI No yes No +601-60 5 PVV-5620 ILI Mai fmpw)) \AnYl Fhed Wrid— 04M/2025 Y" yes Y. N/A Magi �yut Me". Number or th— Qualflor Asouramem 'an" [We Aniannod for Us& AgREQUAla.Un In HVI 0.1.1d. Named RVAZ R,,Wt Deal, Pramaure Mullions for A41 Doom ah d VI Aluirrinum W.9— 05r26W28 yes yes y" WA 2 Vertical Aluminum lAullon IM117024 No yes Y" MIA Florida Depertment of Business & Professional Regulation Pois 1 fl Floricke Deportment of Business & Professional Regulation Pole I or I Florida Deportment of Business & Professional Regulation Page I III Florida Dopeftment of Business & Professional Regulation pwifl Building Codes and Standards i19=1 Building Codes and Standards fAI Building Codes and Standards 1&,021 Building Codes and Standards I Product Approval Application Detail Product Approval Application Detail Product Approval Application Detail Product Approval Application Detail coo Entity or Data Pmldm Aut Q& 21ft JIM& Chate Pending no EnMv or aft 2ft Dab lamidints Clam scow "It 2a oat Fmdm JW& varm- magglaiggim Candea Vabdatd submitted FaCAMIYW A .. �Isd atm. _7k= varsloc N.,Agd.— contsd firmalroKA Licarts, vmdw IN Yaw" steftw LAZAOZMII Asivari &an TVPa Vero— Mnuf-wr. Contact Enalinver & I.Somme Valldhithed k voild" SbmWd FSC Approved APW,%,d at". mm VKW- nwfrach— CNdwt Emol—LUcans, VRdgd IN Validated BLOmr"d FBC Awraym Aimehod gig, Rental- 2020 immam Hands Building Produtts VI Catergor5r. Panel Wells Chad DeI V Andr," Tan John Soultard, P. E (909)545-6359 PE-81862 1352) 387-2-326 01105M21 1WV2020 01,011/2(121 ding FBC Apr. Ren.4— 2D2o Alsift cae2w. Re" Wells Nick Thompson Lyndon F ScbtyWdt. P E� Ryan J, Ift. P, E (330) 922-2399 PII B13)T67-SMS 10125,2020 1012111 1110MG20 1211 5=20 Apprisaml R—lon 2020 CALF Categoarif Robing Morthwill Sfith Robert NiBrI John W. Knerm-AM. RE CaDO)TOS-34111 PIE-541166 4954)7T2-5224 ok2u2o2o OW21r2020 1W20020 1211&-420 Appl—d RA"Asu,, 2020 TAMKO Building loroucts LLC CategI Rooting Kohl Ede Robot Mentrion John W KrobI RE (417) 624-8544 PE-59166 i954)T12-M4 I(YOV2020 091 I0n2n= 12,15r2020 AW.Aidl "Caleighti Sloing "catopow. sons nth—Pson4ahilsi SubCaftgorr. Wet Shinglore -timiciser... subcaosigow. Undemayments kam1_�mI-4Rtam1m­ Cornplion" MOMO* E�Rlustiori Report tom a a— Cornitillones Method E�Iustw Report Irm a Consollamm Nohod; Eymumim Report from a CornpIMrhMs li@Mod: EYVIuI Report tont a Fl.rid.R.0 redAhthiftect—U—sedIFINda Floods RegishersdArchiteetma Uomsa� Florid, Floods Registered Architect or a U—sed Flhddis Froddis Registered N&ftd o, a Umsed Flonda Promme—al Engine. Professional Enginew Engineer Pcifiesimial Eneramer FLAnsismapraduct, Q"Itv AM pubibrowedforuss, AM[owd for Uss ImDwl pedw Imbixt vldm mranm Awrovisid for Use Aborcyrd for Use b= posion FL*1212M%Pmdub inition comw 129LP Prodwit NoM. Nwbw or Ham Protaht Coronado 0 In HI out" Him Rothtwd Proxmire Ink Prpdmt Model. Nurribm or lNume Prodluct compilation CCI*W gxpkllftl out In Hwz out" III ]tedstat Prossure Room mwk Hurieff or Nmy a2a In HVHZ Outside HVHZ Reskt&tt laressure Ant Isrollml Model. Number or Him Proolud Dearledon commi Lotdkn Date In HVHZ outwtltm ROMIM9 Pressurt 1 Carriplank Lip Siding 111so-mmont staking InItim yea yes NIA INA 1 e. &quot:27&wPL SoNk Vant or Solid Mryl Sdffl 12130021 No Y. No HIA I GAP Asphaft Roof Shingles Ftwerew. refiriteroad 3-talb, leminsted, "tend 1 21116=2 No Yes M fA MIA I TAMKO ReO UNdmiyrnents (HI Rof.nddyrranlsfor... in F 9C HVHZ 101IW2021 Y. No MIA NA 2 Hmd.Pkk Lap Sidirg liber—mart lap alking 1201112M yet Y. MIA MIA 2 &q..tAin- T"qitot. Sdffl Vwt w Sold %Any] SoM IM0021 No Y. No WA hlpftkiW Asphalt shingles pridtoes. 2 TAIVIKO R.& I.I.druiphent. thh()N�II Roof undirdayments for use In F BC nI 101181 No yes NA NA juirosobots. Florida Departmerit of Business Professional Regulation Fair, I oil Florida Deparliniont of Business & Professional Regulation Par I it Florida Department of Business & Professional Regulation page I of I Florida Departniont of Business & Professional Regu lation Par 1 o Building Codes and Standards Building Codes and Standards lffl=1 BLdl&V Codes and Standards iffr.021 Building Codes and Standards 1,7=1 Product Approval Application Detail Product Approval Application Detail Product Approval Application Detail Product Approval Application Detail Pat 20 Vater Pending ft2 Goh Eray M 2m 20 ast, lawholina 20 QdI =a.— DID go Dab IsMidno 20 C90 EnI or� a" 2" 09, Pandinds coned Subsedmid FING Amoraval A,,,,W mm version Manufacturer & Uiperwer Validdid 3kjbmYad PBCAMMVW Aborp =M LM version miligUlgigum rdEm XILMam xdwod Subff~ FOC A-surrial A-1ad ZAU zm Vw*iw Manufactures cooled Val"ard W Validated submitted FBIC Anshimsal A,,,-,d sib& R.4.i.n 2020 I.M. Thon"oh. In. We Irompom Amriftwural Metal. Company (TAIMCOt Calwaorr. Fooling Twy Chd*r.n Zadeary R. Preat Slesen K U1.11I PE IhIT)248-345$ PE-74021 .717)3174454 owl ?rl= OW612020 091 12M&M20 Appr—d Rommon 7.020 F[Wde Makell Products I- Calegary, Rolhil SubCostilturr. Roollrig A —sores that are an Clark k... James L BuiNkm, Is E.Q S1— AI thich. PE (904) 7&1-W0 CSUCK Engineering (?17) 317-8454 ciw*v�� PE-31242 092712IDN 094257120 101"1 12MI52020 Approml RI 2OW Lomenoo Cadegorr- Rhsi SubCallegarr. Reuling Acoonaorkins that we an Kistrins, Mey Jamee L S.�khm, PE Stahmn as III PE (501)9"163 PE-31242 (717)317-8454 obisi 1 U23=20 11/2SrM ilrmm dro FBC Appr- RoMoon 2D2a 8-1 Rooting Calogissir Rci�*rg gLi".g.,r- heeling Tle. Anderson Robin LAPAND uniferry, F�lu.w Gary W. Water (801)380-6091 S.M., 11 (205) 854-0160 RdAnAnde"bonal.co i 1133r2D20 I II IIM-%W20 Approved "Category. Roolng Accoareares thet No An himeral Pan offlid, Rooling System lide" Part Brine RoNrigIlysterfin Comple-e Mdffiod! Evalustion Report from a integral Part orthe Fooling SYmorn CarVii�gothDd: Evaluation Report it= a Compliance method: Eaiijalks, Resport turn 2 Produot Ealisadon Fray C�lVllanC4 Method Emitiatiort Report from a Floods Registered Architimt or a Licensed Florida Florida RegisteredArcliftect or a Licensed Florida FtodftRV radArdiftectoraLlomsedFloridi, Professional Engine. Professional Engineer Professional Entarees FUMOR&OP�n�,k PLA172814&Pndmts Quaft Outerwear Anbrowd for Use Awronsid far Um know pedw PL*ISMSM lanodda aw Cogged liagired M HVINZ Out" HvKZ Resistant Ish—ra QudRy Assuraii Aultheyeril far Us* fluagroyed for Use MW 2tft ANA Product Model. Number or N� QuiWKwAsur� P'Natot Deserted- Contract Excirabors Anai for Use ADDMVIW foLu" I in Mwz Outold, HvHz know R.#Ftt D"km Prassuirs NEI Product DmrktWn Contract Exultation Date Accraniod for Us# ApproWd in HVMZ outsia, for LWO Israeli I Resistant Chastan F4� is S;Qg:fttk,h,,N,— . Shake, Cbuntry SIN SPIN Old Endish Th&I &—p; limped Fiat Profile - N—, CO 1 ?13112020 No Yes MIA MIA Aga I 2 3 4 ZMMLIMgdvjkmwLauum TANICO Flat Top OftReg. Vent ft Smile tor TN. TAMI Gmoi Vans TAMCO CIFT-Ridgro Roof Vart �fth Bafk TAMCO Roumd Top 0,11-Rial Vent vAth BI for Tile Product Descrinflon contract Emaintion Oak, 26 Us. Auto. rhf..MM. wits taffle 0SM9I 2691 011091206 20 9L italic roofv"Ithator win Integrated tauffle, O&MM 20 ga. Mato fwf vordiattor vefth baffle 091001 1, HVHZ Oubdide yes No yos yes HVW yes Y. y" yes fl,9stmt N/A NAA MIA Nhk leressure WA -0�52.5 WA N/A 3 3- FLAI &QLki 10 Ridge Ventitituct: AJumhum Ridge Varts for pitmed! rooft fabricated 12131=24 "in 0.025'Alumir— He Yes No WA I =Mj=ft'I DA-4 L— Profit, Policiropylawas Pamt, Rod Vant 12flOt2025 hilsNewitchisly Afhadw to Pil D.,k No yet No -975�97.5 17 16 9 20 27 28 Booby 600 - Skate. Shake Aamp; SON Shake SamI - Shia. Shake &—p. SON Shake SONY 700 - Shake, Sea &—P: SON Shake Sekxw=SII State A.mo; SPIN Shake Tell 1 B .. hon. 'Alla Fituftfle-Slockt. CA 12131202D Flat Profile - Riskil. CA 12t3lrMD Fiat Profilar - Stockton, CA 12131r"D Fist Pmflai RI CA r"o i 2131 Men Pratte - Katy. TX 213 1 Q020 LoI Proft - Katy. rX inim" No Yes No Yet No yes No Y.: No Y. No Yes NA MIA MIA MIA NfA NIA MIA WA WA N/A WA M/A Florida Departhrent of Business & Professional Regulation Pass I al Florida Department: of Business & Professional Regulation Paris I at Florida Department of Business & Professional Regulation Part al Florida Dspartniant of Business & Professional Regulation Page I rI Building Codes and Standards WrA21 Building Codes and Standards 1,7=21 Building Codes and Standards 1,71=1 Building Codes and Standards Irumi Product Approval Application Dealt Product Approval Application Detail Product Approval Application Detail Product Approval Application Detail mm Version MnLfrKwra Brubt, or Called BrAhmff & Ue,msma Validated N KiTmillillillillill 2" 2" valiakw 3Ld3mktod will DA, Issandino F&C Awmal 20 Althonoved Status mm Vani magLaGglIm er4gy CErtact N&ad" 20 adt Dale Pandina validated Subenfitsel FBC AnUAWS 2n A—,d MAU Small MM Version Manufa=r� gmt, Conted bxb,m a lJoNithe Vallithitild By all 211 VW[dd" aultnitted luds, Pentsmat FBCADID[OVII Awasm,%sid ateA Ilia vertion P"ufutuf� 'Iffillil EfktW w cort.01 Valittated W 1111111 29& 2" Data P-d- Vglddd &AnktA P13C Aniumbrall 20 RtIlson 2D2a Global Protect. Prdcts, LLC. Category: Shutters S.IoCal.g.ty, Stoms Panel. r—pl]—MWhod: E-luall. Report from Tim Robin— Walter A, TVIR J�. RE. John W. Kh-ti PE (954) OW7545 PE-44167 (04) ?72-8224 OSAMM20 09mno2o 1=1/2020 12115M20 Aqpr�d fmftorn 2020 All Areadosto Shutter. and Glass Colossi. shutters likulloCiamilairr. eta. panels Co"ftnw Mdhod! Lveluation Report thorn, a Mike Gabon Fmnk L, Bernardo, RE Troy Bishop. P'L (5611712-9862 PE-0048541ir ii)554o 947-000 iliell,@.lemaricanshutle, 3.4 Am 1012armzu 1 M V2020 110=020 IV1512020 Approd ReAsion 2020 A1pInv tategiory-. Stixtuml Comp—rts Subcategory; Truss Flat" C.Mil— Method: Report from St—t Upis ICC E-IN ANN S-4., LLC Wilion I R.rII PE k321) 710-3377 (407� 31 10ISIQ020 1 ora=20 11005=20 11IW2020 AppI Re%49W 2020 C ornmearcal Concreas ProdLI Category, Strodural Camison.," S.IsCothiliI. Prdutl, trt,.du.d .1. Result .1 Not Technology Robert Gill, Samel A. Grombeirli John Way (1913)M-3707 PE-34245 (352) 581 I2tI6I 12/16=20 12r,'WB20 ding FBC Appi Fiodda Realstored Archrled or a Limsed Florida Pro(assrorw Enginw Flondis Registered Arhitt or is LiI sed Florida Profthalwo Eight— Prod= Eahuatkon lirtity Caorillance Ndhw: Evaluation Report it= a Fordat RelifirthriedArdifted or a Uftraed Florlde ELtimmaLaat= tuanstainiam FL"904yptodmm professional Engineer Chadhe As— A,,,,d for U- Asa -red for use hijust peak. QW, A—, A,,,,d fie, Use Aussroesel for us, knotest ohamms 11111.1 PrIalm MocbL Kuntw of k� duties Ae— prouluat Dishmistion Amend for Use Aushroamal In HYHZ otxsfcb for U, owed R"NM 20" Prehowne F1.11117Y44M AMA 1 Produst Model. Number or M— 20 Gage Gainntud Red Storm Parms/HVHZ Product 0—rhadoin srs CA, Corrugated GO—IbIed Steel Storm P—lamitimstl 17nl,2021 1. HVHZ CLAsId, yes HVHZ Yes assistant Y. Pres-rat MJA AW 1 Preset MdL Murather or it— 24U. Ge-rizod Steel Storm Panels C,*,d Eavirration 09, 24oa Gainvinkeed Steel Storm Panels 1MIrIO21 In KVMZ Outoolle HVHZ Y_ Y. Resistant Pres— Y. NVA I 2 MW BCGhNo. MUM, Str-gth tH &..p; S) ITW SCGAsom Hinge Plate Metal comessor Plate 17J 1=24 Metal connertor Plate 1131=4 Y. Y- yqs MIA Yet NfA N/A MIA it" ==w"C1.*MwWMQNuCQnI ckwiw A,-- Product Camerlittlor, cmram EJMA,atim AnimayadfurUsia Attorowed for Use ca. an MvHz Outside lastrat assistant pask. PrehishI 2 24 Gage Galywizod Steel St�m PaftaIs1NHVHZ or rot y"Fles 1. pI hun". pnot-bon. CNI Gsbmnumd Slawal Storm Panels retained I V31,2021 NO Yes yes WA 3 4 rrW BCG/Aoim Tways ITW BCGffiom Wanm Metal C—ort. Plate V3, 2024 hdd.l C—actor Plate IZ(31=24 Yes V. Yes MIA Yes MIA N/A N/A 1 Products Precast And Presetresse d Controls LII 051 N. Yes NIA, WA a not by trade to proOtle hu hicame proittdor. FWda Deportment of Business & Professional Regulation Pepsi Pit Florida Departmard of Business & Professional Regulation Page I (I Florida Departrinent of Business & Professional Regulation Page I IN 1 Building Codes and Standards ir=21 Building Codes and Standards frl2D21 Building Codas and Standards 117re.1 Product Approval Application Detail w�l!itillivilillem Product Approval Application Detail : : ;'1 1 1 1 1 w 11 1 1 Product Approval Application Detail Entftv 2a 20 DI Nn(im mt SAft 1, 1! 1 � i! 111 111, i i EMENNIMMENWAMMEMIN me 20 [1 Pan 20 Qk —_ —_ �I= I or I I I I I 101 ii 299 a" DAPmg, a" mm version kUnufactumr Sulornittad FBC Awroyal VW- Submitted F&C A,,U,,# Athernoved Aligiall BM vwdo UiPhim 3ukNrk1N*d FBC Approval ADIXO Revision 2020 Mrrk In. Oln Waken ICC r-l-bern &.,A., LLC ICC svw.mi- a—, I W=20 OW3&020 10mit"20 App,-.d R.I ZD20 Welmdratuslis Rob B@Jo*n ICC Evaluation SaI LLC lan L#II P.E. I W1 W2020 Applied For Rer,,alon 2020 CAST-CRETE USA LLC Craig Perri hllwm�D.d. SCCO - CER MI-him-Dd. BCC0 - VAL iiam2o lOf2712020 I JJ27.M20 Appro-d CalhagW Strukturat Camison ntse IVI 8g"635 LIC categiew. smural compoter" (253)W4.6478 (BOB) 839-3288 Category: SUIW.ral Cmapmeha, L813162i44641 (7861315.2590 SubCalegory: IN" Pat" —adai com (205) 599-OON SubCategoirr. Enginomed Lumber Subcategory, ProdI Introduord as a Result of qn1n.&.%1cnI Comilphance; Method: Evalvieft Report from a Corriallaroo Method: EVoluation Report from a New T.Nn.I.V FLM2741IPh,by�ft P—luct E,,%I 1I PLAM?4t" Product E-lustion Eh* prpalds Cornplia— Method: Cohdombon kbrk or DOI AW CMWKVAR—amt M"l Awrohnad for Ows Aborovied lmvwz OLdd& for Un HVNZ imow Resistant DIS[W Pressure it" RUN I= Q"UV A,—, Product Dwithation C Atioloned for the Awroyed for Use In NVHK outside 1m.Nt lt#dgw oftedon PRlmro an& NKD* 0,M� A—, A —said 1, 11- Aneer—t In KM outside for Ifte bm,,a flewshus Dission Pr"sum 1 MI I a ga wpm h Igh strenoth trust 0—ax plate 061 yes Yes MIA MIA I N. Lim-driewd V.— I.—b., 0"1=1 No yes MIA WA I High Strength Camels I-Intes 4, 0, 8. and 12 lh *dq III 05nIfXQ2 Yes yes NIP, NA 2 111 16 ga. truss =noo" plate QSMR021 yes ya: NfA MIA 2 Isirrill.. PSL Faster Strand Lumber 03/3i=l No Yet MIA WA 3 MT 1" 1 a Us. high su"Ilth trust t,woedff plate 01hrJV021 Yes ye MIA MIA 3 Thrmerfibra no L! Larrmated Strand Lurnber 0=1=1 No Yes MIA WA 4 MT20 20 ga- trith" connector the e ON300021 yes Yes MIA N/A 4 TJ Film Board Molural Composite Lurnber a oriented Strand G3131/2021 No Yes HIM NJA 5 NII 20 g. high Strength ". corimedor Plate 06/30=1 yes yes MIA MIA 5 WOymneau-1illm III b .. d Rk. Board oriented Strand Beard Rim Board ami=l No Yet MIA WA cn -a —Cu > 2 0 cu —0 cn -.0 CU 0 0-0-0 - CU (n 2 I C) .0 a 0 CU U_ "_ 0 CU > ci 0 L- cuu) -0 co z z w mi ICU C: 0 I CIO U U) _tf 0 (1) C/) CU 0 Smom CL co CL -4--illill < C/) 0 LN Cl) CU w __j a_ SHEET NO. PA 1.1 , I , , , I 1�� "I I Simpson Strong -Tie 2020 FBC Approved Products Updated 12IM020 Simpson Strong -Tie 2020 FBC Approved Pro -ducts Updated 1213012020 Simpson Strong -Tie 2020 FBC Approved Products Updated 12rJ012020 Simpson Strong -Tie 2020 FBC Approved Products Updated 12130,172020 For direct Inks to all SST approvals listed below: CLICK HER For direct Inks to all SST approvals listed below, CLICK HER For direct Inks to all SST approvals listed below, CLICK HER For cirect Inks to all EST approvals Ned betow, CLICK HER For additional Information regarding Flori Statewide Product Approval SySleM and Man i-Dade County Notice ofAcceptance NOA), CLICK HER For additional Information regarding Florida's Statewide Fro(luct Approval System and Manii-Decle County Notice ofAcceptance INCA). CLICK HeR For additional Information regarding Floircla's Statewide Product Approval System and Marni-Dade County Ncitice or Acceptance (NOA), CLICK HER For additional Information regarding Flonda's Statewide Product Approval System and Marri-Dade County Notice of Acceptance INCA). CLICK HEIR FL#23W-R7 FL#1 0446-RG FL#I 0456-1115 11 HUS, HUSC series hangers Face -mount hangers available in Wdths ranging from 1.518" to 3. 9/16" and heights ranging from 4-5116'to 11". Concealed flange Ig" Product Model, Number or Name Product Descrintion 22" Product Description JW Product Model, Number or Name Product Description version (HUSC) available for models having width equal to or 1 Titan Stainless Steel Concrete & Masonry Screw (TTN-SS) 1/4" diameter Titan stainless steel masonry screw 1 A21, A23, A33, A34, A . A44 Angles I BT,BTB.BTH Brick Ties greater than 3-9116" 2 APA21, APA4, APA6, APVA21, APVA4, APVA6 Outdoor Accents Angles 2 CMST12� CMST14, CMSTC18 Coiled Straps 12 IUS series hangers Face -mount hangers available in widths ranging from 1-718" to 3. 3 APE344 , APB"R, APVB86, APBOOR, APB88. APB88R. APB1 010, APB1 01 OR, APVB44, Outdoor Accents Post Bases 3 C514, CS16, CS18, CS20, CS22 Coiled Straps 59" and heights ranging from 9-1/4" to IS' FL#958i APVB44R, APVB66 APVB66R, APVBB8, APV988R, APVB1010, APV8101 OR 4 CSHPIS, CSHP20 Coiled Straps 13 LGU3.25-SOS, LGU383-SDS, LGUS.25-SOS Face -mount hangers 4 APDJT2A. APDJT2R-4, APDJT2-6, APDJ72R-6, APVDJT2-4, APVDJT2RA. APVDJT24 Outdoor Accents Dock Joist Ties 5 CTS218 Compression/Tonsion Strap 14 LU24. LU26, LU28, LU210 Face -mount hangers Product Model, Nufn bar or Name Product Descrittillon APVDJT2R-6 a DSP, SSP, TSP Stud to Plate tie 15 LUC26Z, LUC21 OZ Face -mount hangers I SDI 01 12DBB Outdoor Accents Conn ecto r Screw 5 APHl APHH46R. APHH61 0, APHH61 OR Outdoor Accents Heavy Hanger 7 H1, HIOA, H2.5A, H3. H6, H7Z, H16, H18S, H16-2, H16-2S Hurricansi 16 LUS series hangers Face -mount hangers available in widths ranging from 1-91161c, 4- 2 SD91 12, SD92112, SDI 0112, SDl 0212 Strong -Drive SD Connector Screw 8 APL4, APLO, APT4, APT8, APVL4, APVL6, APVT4, APVT8 Outdoor Accents L and T Bearn-to-Column Ties 8 HGT-2, HGT-3, HGT-4 Heavy Girder Tiecloym 518" and heights ranging from 3" to 10-1 Sh 6' 3 SD9112SS. SD9212SS Sitrong-Drive SD Connector SS Screw 7 APLH24. APLH24R, APLH26. APLH26R, APLH210. APLH21OR Outdoor Accents Light Hangers 9 HS24 HurricansTie 17 MGU3.63-SDS, MGU5.25-Sl MOU5.50-SDS. MGU5.62-SE)S, MGU7.00-SDS Face -mount hangers 4 SDCF22434, SDCF22512. SDCF22614, SDCF22700, SDCF22858. SDCF221014, Strong -Drive SDCP Timber-CF Screw 8 BVLZ Brick Veneer Ledger Connector 10 HSS2-SDSI 5, HSS2-2-SDS3, HSS2-3.SDS3. HSS4-SDS3 Heavy Stud Shoe IS MIU series hangers Face -mount hangers available in wdths rangingfrom 1-9/16"to 5- SDCF2211$4, SDCF221334. SDCF271958. SDCF272358 9 CBT2Z CBT4Z Concealed Beam Ties 11 HST2. HST3. HST5. HSTO Straight Straps 1/8" and heights ranging from 6-15116"to 19-10. 5 SDCP22434. SDCP22512, SDOP22614, SDCP22700, SDCP22&58. SDCP22912, Strong -Drive SDCP Timber-CP ScrLvv 10 CJT3Z. CJT42, "5Z, "6Z Concealed Joist Ties 12 HTS116� HTS20, HTS24. HTS28, HTS30, HTS30C Heavy Twist Strap 19 MUS26, MUS28 Face -mount hangers SDCP221100, SDCP221134. SDCP271400 11 DJT14 Deck JorsitTie- 13 HTS01 6KTZ, HTS020KTZ Heavy Twat Strap 20 SUR. SUL. SURC, SULC senes hangers Skewed face -mount hangers available in wklths ranging from 1 - 6 SDHR27400, SDHR27614. SDHR31400, SDHR31614 Strong -Drive SDHR Combo -Head Screw 12 DS Dry Wall Stop 14 LFTA Light Floor Tie Anchor Off 8" to 3-9/16'and heights ranging from 3-111 &'Ito 13-314"� 7 SDS25112 SDS25134, SDS25200, SDS252112, SIDS25300, SDS253112, SDS25412 Strong-Drrve SIDS Heavy -Duty Connector Screw 13 FC4 FCS Framing Clips 15 LSTA9, LSTA12. LSTA15, LSTA18, LSTA21 LSTA24, LSTA30, LSTA36 Straight Straps Concealed flange version (SURC, SULC) available for all double SOS25500 SDS25500, SDS25800 14 FWANZ Foundation Wall Angles 16 LSTI49, LST173 Straight Straps 2X and 4X models; on ly a"e flange is cono"Ied. 8 SDS25112SS, SDS252OCSS, SDS25212SS, SDS2530OSS, SDS25312SS Strong -Drive SIDS Heavy -Duty Connector SS Screw 15 GAI. GA2 Gusset: Anges. 17 LTB20, LTB40 Bridging 21 U series hangers Face -mount hangers ayeilable in wdths ranging from 1-9116" to 9 SDWF2716, SDWF2720, SDWF2724, SDWF2726, SDWF2730 Strong -Drive SDWF Floor -to -Floor Screw 16 H2A, H2.5T, HIS, HlOA-2, HICS, H14, HGA10 Hurricarl 18 LTS12, LTS16, LTS18, LTS20 LightTwistStrap Wand heights ranging from 2-5/8" to 11-114" 17 HCJTZ Heavy Concealed Joist Tie 19 MGT MediurriGirderTleclown 18 HH41 HHS Header Hangers 20 MST27, MST37, MST48. MSTOO, MST72 Straight Straps FL#1DD07wlR8 19 KBSIZ Knee -Brace Stabilizer 21 USTAP, MSTA12. MSTA15, MSTA18, MSTA21, MSTA24, MSTA30, MSTA36 MSTA49 Straight Straps FIL810967-RIS 20 1_30,1_50,1_70,1_90 Angles 22 MSTC28. MSTC40, MSTC52. MSTC66, MSTC78 Straight Straps Product Model, Number or Name Product Description 21 LCG4 Post Cap 23 MSTC48B3,MSTC6883 Pre -Bent Straps Sea 9 Product Model, Num ber or Name Product Description I ATR�18. ATRIiZ ATR5/8. ATR314 Threaded Rods 22 LS30, 1.550, LS70, LS90 Skewable Angles 24 MSTI26, MSTI30, MST148, NtSTIOO, MST172 SIF*ht Steps I BA series hangers Top flange hangers available in Wdths ranging from 1-9116" to 7- 2 ATUD5. ATUDO-2, ATUD9, ATUM2, ATUD9-3, ATUD1 4, ATUD14-2 Aluminum Take -Up Device 23 LSCZ Adjustable Stair Stringer Connector 25 MTS12, MTS18, MTS18, MTS20, MTS24C, MTSSO, MTS30C Medium Twist Strap 118" and heights ranging from 7-118"to W'� 3 Bl BP112, BP1/2-3, BP5/8-2, BPEVS-3t BPW4, SP314-3, BPRTU03-4 Bearing Plates 24 LSSJ26LZ. LSSJ20RZ, LSSJ28i LSSJ28RZ, LSSJ21OLZ, LSSJ210RZ Field Adjustable Jack Hanger 26 NCA2x1O­12, NCA2X12-12, NCA2x8-16, NCA2x1O-IO, NCA2xl2-16 Bridging 2 DGBF series hangers Top flange hangers available in widths ranging from 3-518"tc, 7- 4 CNW318. CNW1t2. CNW518 ONW314, CNW5f8-1/2, CNW3/4-518 Coupler Nuts 25 LSSRI.81, LSSR2.1, LSSR2.37, LSSR2.56. LSSR210-2, LSSR410 Field Adjustable- SlopeableiSkewable Hanger 27 RCW1312, RCW814 Wall Bracing 115" and heights ranging from 9-114" to 24", 6 CTUD55, CTUD65, CTUD65, CTUD75, CTUD76, CTUD77, GT UDST CTUD88. CTUD97, Coupling Take -Up Device 26 LTP4,LTP5 Tie Plates 28 RPSIS, RPS22, RPS28 Repair Plate Strap 3 DGF series hangers Top flange hangers available in widthis ranging from 1 -1 rZ'to 3- CTUD98, CTUD99 27 ML23Z, ML24Z, ML262, ML28Z. ML21OZ Angles 29 RSP4 Stud to Plate Connector 5/8" and heights ranging from 7-114" to 24" 6 N3. N4, N5. NO Heavy Hex Nuts 28 Mli RoofTie-Dcwr 30 SP1, SP2. SP4, SP6, SP8 Stud Plato Tie 4 DGHF ashes hangers Top flange hangers available invividths ranging from I -W4" to 3- 7 RTUD3, RTUD313, RTUD4, RTUD4B. RTUD5. RTUD15, RTUD7, RTUD6 Ratcheting Take -Up Device 29 MMHG Hinged Roof Connector 31 SPH4, SPHOI, SPF18 Heavy Stud Plate Tre 518" and heights ranging from 9-114" to 24"� 8 TUD9, TUD10 Take -Up Device 30 MMLU26, MMLU26-2, MMLU2S, MMLU28.2, MMLU210, MMLU121 1, MMLU139, MMUU13I1 Face -Mount Hangers 32 SS1.5, SS2.5, SS3, SS4.5 Stud Shoe 5 EG5� EG7, EG9 sores hangers Top flange hangers available in wdths ranging from 5-114" to S. 9 TUW38 Take-UpWasher 31 RBC.RBCP Roof Boundary Clips 33 ST9, ST12, ST18 ST22, ST292, ST2122, ST2115. ST2215, ST5215, STO224, ST6236 Straight Straps WS" ard heights ranging from 11" to 32-1rZ'. 10 URS3 WS" Uplift Rod Run Tedown System 32 RST-3 RootTie-Down 34 T820. T1327, TB30 TB36, TB42, T848. TB54, TB56 TB60 Tension Bridging 6 EGO series hangers Top flange hangers available in wdths ranging from 3-518" to 7- 11 URS4 lf2" Uplift Rod Run Tledown, System 33 RTC227. RTC42, l RTC44 Rigid Tie Connectors 35 TWBIO, TWB12, TWB14 Wall Bracing 1M" and heights ranging from I 1-1WAto 32". 12 URS5 5f8` Uplift Rod Run Tedown System 34 STC. STCT, OTC. HTC4 TrussClips 36 VGT, VGTR,VGTL Variable Pitch Girder Tiedown 7 GLS series hangers Saddle hangers available in widths ranging from 3-1/4" to 6-7JIT' 13 URSO 314" Uplift Rod Run Tiedown System 35 TJC37, TJC57 Truss Jack Clips 37 W61 00, WBI 08C, W81 26, WBI 26C; WB143C Wall Bracing and heights ranging from 8- 1/2" to 28"_ 36 Z2, Z4, Z44 Panel Stiffener Clips 8 GLTV series hangers Top flange hangers available in wdths ranging from 3-1/4" to 7- 1 /8" and heights ranging from I I " to 32". FL#10441-R6 FL#10531-R5 9 HS series hangers Top flange hangers available in widths ranging from 1 -911 5"Itto 7- FL#1 0447-RS 1 J2" a nd heights ranging from 8" to 39'. Product Model. N um bar or Name Product Description ProduCt Model. NUMber or NaMe Product Description 10 HGLS series hangers Saddle hangers available in widths ranging from 5-114" to 8-7f8" 1 DTT2 Hold-down Sag If Product Model, Nurn bar or Name Product Description 1 CeH2,37x5 5, CBH2.37x7 $3. C61-12.374-75 Concealed hangers and heights ranging from 10-1/7'to W'. 2 HDC10/4, HDC10122 Hold-dow 1 AHEP Adjustable Hip -End Connector 2 DU. DHU, DHUTF series hangers Face -mount (DU, DHU) and top -flange (DHUTF) hangers 11 HGLT series hangers Top flange hangers available in wdths ranging from 3-114" to 8- 3 HDO8. HHDO11, HHDO14 Hold-down 2 DSC2R-SDS3, DSC2L-SDS3, DSC5R-SDS3, DSC5L-SDS-3 Drag Strut Connectors 2vailable in widths ranging from 1-9flff'to 3-9/18" and heights 718" and heights ranging from 7-112'to 32' 4 HDU2. HDU4 HDU5. HDU8, HDU 11. HDU1 4 Hold-dow 3 GBC Gable Brace Connector ranging from 9-1/8" to 23-15116". 12 HGLTV series hangers Top flange hangers available in widths ranging from 3-114" to 7- 5 HPA28, HPA35 Strap -style purlin anchor 4 HCP1.81, HCP2. HCP4 Hip Corner Plate 3 HGU3.63-SDS, HGU5.25-SI)S, HGU5,50-SOS, HGU5.62-SL)S, 1-IGU7.00-SIDS, HGU7.25- Face -mount hangers 118" and heights ranging from 14" to 33", 6 LSTHD8 LSTHD8RJ Strap -style hold-down 5 HHRC2-2, HHRC42, HHRC42-2 HHRC411 81, HHRC", HHRCS.2".25 HHRC5,37t3.IZ Heavy Hip to Ridge Connectors SDS, HGU9.00­5l 13 HIT series hangers Top flange hangers avaitable nwidths ranging from 2-5116'to 3- 7 MASA,MASAP Foundation anchor Strap HHRC86 4 HGUS series hangers Face -mount hangers available in widths ranging from 1-518"to 7. 9116" and heights ranging from 16" to 26' 8 MPA132, MPAI" Strap-s" purlin anchor a HRC1,81, HRC22 Hip Ridge Connector 318" arid heights ranging from 5-5/1 O"to 12-718". 14 HUSTF series hangers Topflangeloist hangers available in widths ranging from 3-1/8"to 9 PA18, PA23, PA28, PA35 PA51, PA68 Strap -style purlin anchor 7 URU26. LRU28. LRU210. LRU212 Rafter Hanger 5 HHGU5 25-SDS, HHGU5.5O-SDS, HHGU5 62-SDS, HHGU7 OO-SDS. HHGU7 25-SDS, Face -mount hangers 3-911 6'and heights ranging from 5-18" to 13-1/8" 10 PA118, PA123. PA128 PA135 Strap -sty* purlin anchor 8 LSU26, LSSU28 LSSU210 Light Skildeable/Skewable U Hanger HHGU9.00-SDS 15 HUTF HUCTF series hangers Top flange hangers available in widths ranging from 1 -9116'to 5- 11 STHD1 0. STHD1 ORJ Siraid-stryle hold-clavvin 9 TBE-4. TBE6 Truss Bearing Enhancer 6 HHUS26-2, HHUS28-2, HHUS210.2F HHUS46, HHUW HHUS41 0, HHUS5.WIO Face -mount hangers 1f2" and heights ranging from 3-7116" to 15". Concealed flange 12 STHD1 4. STHDI 4RJ Strap -style hold-down 10 TC24 TC26. TC28 Truss Clip HHUS7 25110 version (H LICTF) available for all models having ww& equal to or 11 THA29, THA213, THA21 8, THA218-2, THA222.2, THA413, THA41 B, THAC418, THA422, Adjustable Truss Hanger 7 HSUR, HSUL, HSURC, HSLILC series hangers Skewed face -mount hangers available in widths ranging from 3- greater than 2-9116". THAC422 THA426, THA422-2, THA426-2 118" to 5-IJ13" and haights ranging from 4-314" to 15-314"- 16 HWP series hangers Top flange hangers available in widths ranging from 1 -9116" to 7- 12 THAI 1.81/22, THAl2 M22, THAl2.1122, THA1222, THA1322, THAI3522, THA1422 Adjustable Truss Hanger Sized for 1-iolists Concealed flange version (HSURC, HSULC) available for all If8" and heights ranging from 5.31&'to 28"� 13 THAL422, THAR422 Skewed Truss Hanger double 2X and 4X models; only acute flange is concealed. 17 HWPH series hangers Top flange hangers available in widths ranging from 1-9116" to 7- 14 THJA26, LTHJA26, LTHMA Multiple Truss Hangers 8 HTU26. HTU28, HTU210, HTU26-2. HTU28-2. HTU210-2 Face -mount hangers 1f2" and heights ranging from 5-3/8" to 32'� 15 THJM2-"DS3, THJM2-5-SDS3, THJU28, THJU26-W Multiple Truss Hangers 9 HU. HUC series hangers Face -mount hangers available in widths ranging from 1-9116" to 7- 18 ITS series hangers Top flange hangers available in widths ranging from 1-9/1 61c 3- 16 TSBR2-24 Truss Spacer -Restraint 112" and heights ranging from 2.718:'to 19-114"- Concealed flange Sf!3" and heights ranging from 9-118" to 16' 17 VPA2, VPA25, VPA3, VPA35, VPA4 Variable Pitch Connectors version (HUC) available for all models having width equal to or 19 JF3 series hangers Top flange hangers available in width of 1�9116" and heights 18 VTCR Valley Tru as Clip greater than 2-9116" ranging from 5.318" to 7-VAl" 10 HUCOI 81/9-SOS, HUCC1.81111-SDS, HUCQ210-2-SDS, HUCQ210_�_SDS, HUCQ310- Face -mount hangers 20 JSA series hangers Top flange hangers available in width of I -9116'and heights SDS, HUC0410-SDS, HUC0412-SOS; HUCQ5.25g-SDS� HUC05 25/11-SDS, HUCQ610- ranging fromig-MO" to 13-1/8" SDS, HUCQ612-SDS Simpson Strong -Tie 2020 FBC Approved Products Updated 12/3"20 Simpson Strong -Tie 2020 FBC Approved Products Updated 12rWA20 Simpson Strong -Tie 2020 FBC Approved Products Updated 12rJW2020 Simpson Strong -Tie 2020 FBC Approved Products Updated 1Z50rA20 For direct Inks to all SST approvals Ned belom. CLICK HER For direct Inks to all SiST approvals listed below, CLICK HERE For direct Inks to all SST approvals Ned balum, CLICK HER For direct Inks to all WT approvals Ned below, CLICK HER For additional information regarding Florida's Statewide Product Approval System and Marti -Dade County Notioe of Acceptance INCA), LLQLbifag. For additional Information regarding Floricla's Statewide Prockict Approval System and Marni -Dade County Notice of Acceptance (NOA). CLICK HERE. -For additional information regarding Flonda's Statewide Product Approval System and Mam -Dade Ownty Notice CfAcceptance INCA), CLICK HERE, For additional information regarding FloncWs Statewide Product Approval System and Marti -Dade County Notice of Acceptance (NOA). CLICK HERE, 21 LB series hangers Top flange hangers available in wdth of I -9/16'and heights FL#1 14WRO 18 SILBV1,56, S/LBV1.81.S1LBV2,06, StLEV2,37, S&BV2.56, S&BV2.68, S/LBVS.12. Top Flange Joist Hangers 5 SET-XP Adhesive Anchor for concrete ranging from 5-3/8" to 15-118" SfLBV3.56, SJLBV3.62. VLBV4.06 StLEV412, SfUBV4.28, SILBV4.75. S/LBV5.50 8 Strong -Bolt 2 (ST02, STB24SS, Srl Strongi-Boft 2 Wedge Anchor for concrete available in carbon 22 LBAZ series hangers Top flange hangers available in wdth of 1-9116" and heIghts 4jill" Product Model, Number or Name Product Description 19 SfLTT20, WTT2Z, S/HTT14. HTT4, HTT5 Holdmvns stoeland Types 304 and 316 stainless steel ranging from 9-3116" to 13-118". 1 HHUS210-3, HHUS210-4 Joist Hanger 20 SIMST60, MST72 Straps 118 mil (10 ga) 7 Titan HO (THD-H, THD-HMG, THD-H4SS, THD-H6SS, THD-CS, THD-CSSSS) Titan HD Heavy Duty Screw Anchor for concrete and masonry 23 LEG3. LEG5, LEG7 series hangers Top flange hangers available in widths ranging from 3-1X'tto 6- 2 HRS6. HRS8, HRS12 Strap Ties 21 SP4,SPS Stud %to Ties avallable with hex head in carbon steel and Types 304 and 316 718" and heights ranging from 9" to 33-1 r2' 3 HUCO210-2-SDS, HUC-0210-3-SDS, HUC0310-SDS Joist Hanger 22 SSP, DSP; TSP Stud Plate T *a stainless steel, or with countersunk head in carbon steel and 24 MEG6, MEG7 series hangers Top flange hangers available in widths ranging from 5-1/4" to 6- 4 THGB2, THGB3. THGBH2, THGBH3, THQBH4 Joist Hanger 23 STC,DTC TrussClip Type 316 stainless steel 718" and heights ranging from 9" to 32-1 /7' 5 THGC2-SDS3, THG03-SDS4 5, THGOH2-SDS3, THGCH3-SDS4 5, THGQH4-SDS8 Joist Hanger 24 TBD22 Truss Brace Diagonal 8 Titen HID Rod Coupler (TH037634RC, THD50934RC) Titan HD Threaded Rod Coupler for concrete 25 MIT senes hangers Top flange hangers available in widths ranging from 1-9/1 6"Ito, 5- 6 THGW3-3, THGW3-4, THGW4-3, THGW41A Joist Hanger 25 TJC37 Truss Jack Connector 9 TrIen HD Threaded Rod Hanger (THDB25158RH, THDB37158RH. THD37212RH Titan HD Threaded Rod Hanger for concrete 1/8" and heights ranging from 9-1/4" to 24' THD50234RH, THD10212RH) 26 PF, PFB, PFDB, PFDSB sores hangers Top flange hangers available in width ofl-9116" and heights 10 Wedge -All (WA) Wedge -All Anchor for masonry ranging from 3-318" to 7- 11IT' FILIIII1473-115 FL#13904-RS 27 FIR Ridge rafter connector 28 WP series hangers Top flange hangers available in widths ranging from 1-9116"to 7- Product Model, Num bar or Name Product Descd= JW Prod uct Model. N u m bar or Narril Product Dewriation FL#1 6230-118 118" and heights ranging 9-114"to 32". 1 DETAL20 Double Embedded Truss Anchor I OCQM3.52-SDSHDG, CCOM4.62-SDSHDG, CCQM5-50-SDSHDG, CCTQM3.62-SOSG. Masonry Pet Caps 2 FGTR, FGTRHL, FGTRHR Girder Retrofit Anchor CCTOM4.82-SDSG CCTQMS.50-SOSG, CCCOW.62-SOSG: CCCQM4.62-SDSG, Product Model. Number or Name Product Description 3 H10, H15S. H15-2 H16-2S HurticaneTie CCCQW.50_SDSG 1 AT-XP AT-XP High -Strength Acrylic Adhesive for concrete or masonry FL#10060-R5 4 HETA12, HETA16, HETA20, HETA24, HETA40 Embedded Truss Anchor 2 ECCLQM3.62G4CT. ECCLQM4.62G-KT. ECCLOM5.50G-KT, ECCLLQMD3.62G.KT. Masonry Per Caps 2 ET -HP ET -HP Epoxy Adhesive for masonry 5 HETAL112, HETAL16, HETAL20 Embedded Truss Anchor ECCLLQME)4.62G-KT, ECCLLGMD5.50G-KT, ECCLROM03.62G-KT, ECCLROMD4.62G- 3 SET_XP SET-XP High -Strength Epoxy Adhesive for masonry Product Model. Number or Name Pmduct Descri2WM 6 HGAM10, HM9 Masonry retrofit con rectors Kr, ECCLROMD5 5OG-KT 4 Strong -Bolt 2 (ST62) Strong-Boilt 2 Wedge Anchor for masonry I ABA44. ABA44R, ABA46, ABA413R, ABA66. ABA66R Adjustable Post Base 7 HHETA16, HHETA20, HHETA24, HHETAQ Heavy Embedded Truss Anchor 3 HGUM5 25. HGUM5.50, HGUM7.00, HC3UW.25, H(3UM9.DO Heavy Masonry Hangets 5 Titen 2 (TTN2) Then 2 Screw Anchor for Concrete 2 ABU44, ABU44R. ABU46, ABU46R. ABU5.5, ABU5-6, ABU65, ABU66, ABU66R, ABU88, Adjustable Post Base 8 LGT2, LGT3-SDS2 5, LGT4-SDS3 Girder-riedown 4 LGUM26-2, LGUM26-3. LGUM264, LGUM28-2. LGUM2&-3, LGUM28-4, LGUM21O-2, Masonry Beam Hangers 6 Titen HD (THD-H4SS. THID-HOSS, THD.CSOSS) Titan HD Heavy -Duty ScrewAnchor forconcrete available in 304 ABU88R, ASU1010. ABU10IOR. ABU1212, ABU1212R 9 LTA2 Lateral Truss Anchor LGUM210-3, LGUM210-4, LGUM46 LGUM48, LGUM410 or 316 stainless steel with hex head, arid 316 stainless steel with 3 ABW44Z. ABW44l ABW46Z, ABW46RZ, ABW66Z. ABW66RZ ABW7-7 Adjustable Post Base 10 META12, META16, METAIB, META20, META24. META40 Embedded Truss Anchor 5 MBHA3.12/9 25, MBHA312f1 1.25, MBHA3_5617.25, MBHA3.5619.25, MBHA356/111.25� Masonry Top Flange Beam Hangers countersunk head 4 AC4, AC4R, ACE4, ACO. ACeR, ACS6 Post Cap 11 MSTAM24, MSTAWO, MSTCM40, MSTCMOO Stap Tie for Masonry UBHA3.56111 88, MBHA3 56114, MBHA3.5SfI6, MBHA3.58il 8. MBHA5.5017 25, 7 Titen Turbo (TIM Then Turbo Screw Anchor for concrete or masonry 5 BC4, BC46, BC4R, BCS, BC6R. BC8� BCS2-2Jt� SCS2-316 Post Cap 12 MTSM16, MTSM213, HTSM16, HTSM20 Twist Strap for Masonry MBHA5.5019.25, MBHA5.50/1 1 25, MSHA5-50/11.88. MBHA5 50114, MBHA5 50118, 6 CB44, C1346, CB48, C13615. COSS Embedded Column Base MBHA5,50118 7 CBSQ44-SOS2. CBSQ46-SDS2. CBSQOS-SDS2, CBSQft-SDS2, CBSQ88­SDS2 Embedded Column Base 6 MBHU3.56/9.25, MBHU3.56/11,25, MBHU3.5&1 1.88, MBHU3.56114, MBH U3.56/16, Masonry Beam Hangers FL#16937-R3 8 CC, ECC, ECCU Series Boiled column caps with W1 ranging from 3-114" to 9-11t2" and FLO114WRS MBHU3.56118, MSHU5 60tg 25, MBHU6.50111.25, MBHU5.50111 88. MBHU5 50114, W2 ranging from 3.5f8" to 7-1/2" MBHU5 50/16, MBH U5 50118 AW ProduCt Model, NUM Der or Name Product Description 9 CCO-SDS2-5, ECCQ-SOS2 5 Series Saevved column caps with Wil ranging from 3-1/4" to 9-1/Z'and 10dal Product Descrintlon 1 X34B1016-5K, XISI016, XI BI 018-4K X01S1018, XQI BI 016-4K #10-16 Strong -Drive X Metal Self -Drilling, Tapping Screws with #3 W2 ranging from 3-5/8" to 7-1f2" 1 DTTIZ Deck Tension Tie Drill Point 10 CPT44Z, CPTeSZ, CFIT88Z Concealed Post Tie ease 2 HD12, HDI9 Bolted Holdlowns FL*M 3975-RO 2 XL0114TI224, XL0114BI224-2K #12-24 Strong -Drive XL Large -Head Metal Self -Drilling, Tapping 11 EPB44A, EPB44, EPB46, EPBe6 Embedded Post Base 3 HD36, HD5B, HD713. HD9B Botted Holdowns Screws with #5 Drill Point and Large Diameter Hex Washer Head 12 EPS47 Embedded Post Base 4 HTT4, HTTS, l Tension Ties Sag 0 Product Model, Number or Name Product DescdRiLga 3 XM01 14SI224, XMQI 14BI224-21< 912-24 Strong -Drive XM Medium -Head Metal Self -Drilling, 13 LC844. LCBN Embedded Column Base 5 LTT19, LTT206. LTT131 Lig ht Tension Ties I SDW22300, SDW22338, SQW22438, SOW22458. SDW22500, SDW22600, SE)W22638, Strong -Drive SDW EWP-PLY and TRUSS -PLY Screws Tapping Screws with #5 Drill Point and Medium Diameter Hex 14 U`C4Z, LPCOZ Light Post Cap SDVM634 4 XQ1 I 4S1 224� XQI I 481224-2.5K X1 14S1 224, XQl I 2SI 224, XQ1 12B1 224-2K #12-24 Strong-Onve X Metal Self -Drilling, Tapping Screws with #6 15 MP13"Z, MPBSez, MPB88Z Moment Post Base 2 SOWC15450 SDWC1SSOO Strong -Drive SDWC TRUSS Screw Drill Point 16 PB44, PB44R, PB46 P886, P866R Embedded Post Base FL*13626-R5 3 SDWH19300DK SL)WH19400DB, SDWHIPOWDB, SDWHI98OODS, SI)WHIGIDOODB Strong-Durve SDWH TIMBER-H EXScrew 5 XL134S1016. XU34BI010-5K #10-16 Strong -Drive XU Metal Sol -Drilling. Tapping Screws with 17 PBS44A, PBS46 PBS65 Embedded Post Base 4 SDWH274OOG. SOWH27BOOG. SDWH271300G, SDWH2710DOG, SDWH2712DOG Strong -Drive SDWH TIMBSR-HEX HDG Screw #1 Drill Point is PSV6. PBVIO Round Post Base A&W Product DescriWan 5 SDWS16212, SDWSI6300, SDAG16312, SDWS1 6400 Strong -Drive SDWS FRAMING Screw 19 P044-16. PC46-116, RC48-16. PC64-18. P065-16 EPC44-I& EPC46-16, EPC48-115i, Post Cap 1 SB&8x24, SB7/8x24, SE31x30 SB Anchor Botts a SDWS19800, SDWS119712, SDWS22400,SDWS225OO SDWS22512, SDWS22600. Striong-Dirrve SDWS TIMBER Screviv (interior Grade) EPC84-16, EPCOO-18 2 SST816. SST820, SSTB24, SSTB28, SST834, SSTB36. SSTS16L, SST820L,SSTB24L. SSTS Anchor Bolts SDWS22800, SDWS22900, SDVvG221 000, SDWS221 100, SOWS221200, SOWM1 500 FL#353MRO 20 PC4Z. PC4R7_ PC8Z, PCSRZ, Pr_8Z, PC8RZ. EPC4Z, EPC4RZ. EPCaZ, EPC6RZ. EPC8Z, Postcap SST526L 7 SDWS223000B SDWS2240008, SDWS225OODB� SOWS2260ODB, SDWS228OODB. Shrong-Drive SOWS TIM13ER Screw (Extenor G rade) EPCBRZ SDWS221 OOODB kW Product Model, Num ber or Name 21 PPB44-4Z PPB"-6Z Post Base a SDVVS22312OBB, SDWS22512DBB Outdoor Accents Structural Wood Screw 1 DSSCB43.5. DSSCB4B, DSSC848. DSHS Bypass Framing Drift Strut Connector 22 RPBZ Retrofit Post Base FIL111113872-114 9 SDWS273COSS, SDWS274OOSS, SDWS275COSS, SDWS276DOSS, SDWS278WSS, Strorl SDWS TIMBER SS Screw 2 FC843.5. FCB45.5. FCB47.5, FCB49�5, FCB411 5 Bypass Framing Fixed -Clip Connector SDWS27100OSS, SDWS27120OSS 3 FPHSD34S1O1O, FPHS034E31018, FPHSD34BI016-5K. FPHSD34S1214, #10-16 and #12-14 Strong -Drive FPHSO Framjng-to�CFS Sell - Sag X Product Model, Num bar or Name Product Descriotion 10 SDWV13400 Strong-Dirive SDWV SOLE -TO -RIM Screw FPHSD34B1214, FPHSD34BI214.5K Drill". Tapping Screws FL#10966-R5 I CMST12; CMST14, CMSTC16, CS14, CS16. CSIS� CM, CS22 Coiled Straps 11 STN22 Outdoor Accents Hex -Head Washer 4 LSFC2.25, LSFC4.25, LSFC6.25, SFC2,25, SFC4 25, SFC6.25 Steel Fram Ing ConnoMr 2 HRS6. HRS8 HRS12, FHAS, FHA9, FHA112, FHAI8. FHA24. FHA30, MSTI26, MST136, Straps R7 mil (12 go) 6 LSSC4.25, LSSC6 25, SSCZ25, SSC4,25 SSC6.25. MSSCZ25, MSSC4.25. MSSC6.25, Steel Stud Connectors 12a Prod uct Model, N u m bar or Name Product Description MST148 MSTI60, MST172, SIMST27, SIMST37, VMST48 MSSC4.25KW, MSSC6.25KW 1 FJA, FSA Foundation Anchor 3 HTSI6, FrrS20,14TS24, HTS28. HTS30, HTS30C Heavy Twat Straps FL*1 5363-R3 6 RCKW3, RCKW5.5, RCKW7 5, RCKW3S, RCKW5.5S Rigid Knee Wall Connector 2 FRFIP Flat Retrofit Foundation Plate 4 LSTA30, LSTA30, LST]49, L5773, VISTA9, MS7Al2, MSTA1 5, MSTAI 8, MSTA211, MSTA24 Straps 43 mil (IS g a) 7 SCS43.5, S0845.5, SCS47 5,SCS49 5, SOB411.5, MSCBA5.5, MSCS47.5 Bypass Framing Slide -Clip Connector 3 GH46-6. GH46-8, 01-14", 1731-148-8, GH410-6, GH410-8, GHM6. GH66-8, GH68-O,QHOS- Girder Hanger 5 LSTA9, LSTA12T LSTA15, LSTA18, LSTA21. LSTA24, ST292, ST2122, ST2115. ST2215 Straps 33 mil (20 ga) §2" Product Model. Number or Name Product Description 8 SCS32-5197. SCS62-5197, SCS62-5fl 18, SCS82-51118 Bypass Framing Connector B, GH610-6, GHBIO-8 6 LSLISH3.25. SUBH3 25, MSUBH3 25 Bridging Connector 1 AS 18, AS 18S5, AS I 8S8 18 ga Truss Plates 9 SCM 25, SCW5.5 Head -of -Wall Slide -Clip Connector 4 GLBSA, Gl GLI35C, GLB50, GUS7A, GL8713, 01.137C, GLB7D Glulam Bearing Plate 7 LTP5 Lateral Tie Patte 2 AS 20HS 20 ga. High Strength Truss Plate 10 SJC8.25, SJC10.25, MSJC8,25, MSJCIO,25 Steel Joist Connectors 5 GLBI`512, GBLTS12, GL13T518, GBLT616, GLBT520, GBLT820 Glulam Bearing Plate 8 LTS12, LTS16, LTSIS, LTSM Light Twist Straps 3 AS-20 20 Us. Truss Plate 11 SSB3,51 a Bypass Framing Slide -Clip Strut Connector 6 HGLBA, HGLB3, l HGLBD Heavy Gfulam Bearing Plate 9 11 MSTA36. ST6215, ST6224, ST9, ST12. STI8. ST22, MSTC28, MSTCAO. MSTC52 Straps 54 mii (16 g a) 4 ASHP Hinge Plate Connector 12 XLSH34B1 414, XLSH78BI 414 #14-14 Strong -Drive XLSH Shouldered Self -Drilling, Tapping 7 HGT-2, HGT-3, HGT-4 Heavy Gird w Tiedown 10 MSTC66, MSTC78, STS236 Straps 68 mil (14 go) Sorews, 8 UFP10-SDS3 Universe I Foundation Plate 11 MTSI 2, MTS1 8, MTSI S. MTS20 MTS30, MTS24C, MTS30C Medium Twist Straps 13 XQ1SIOI 8, X01 B1016-4K X0181214, X01B1214-3 SK, X07881224, X07981224-3K, 410-16 V1 2-14 and 012-24 Strong -Drive X Metal Self -Drilling, 9 URFP Universal Retrofit Foundation Plate 12 SIB1.56, S1131.81, SIB2.06, S/52,37, SfB2.56, VBZ68, SIB3,12. SA33.56, S1133.62, S184.06, Top Flange Joist Hangers FL#15730-R4 XQ1 I 4SI 224, XQ1 1411311224-2 5K, XQI 12SI 224, XQI I 2BI 224-2K, X34BI 01 6-51<� Tapping Screws SIE412. S1134,28, SfB4.75, S1135,50 X181016, X18101&4K, XISI214, X1131214.3 5K 13 SfBA21U, SIBA2.12/10. SABA2.12/12, SOA2.112/114, S/BA4.18/81 SIBA4.18/10, Top Flange Joist Hangers ki" Product Model. Number or Name Product Descricition 9BA4.18/12, VBA4,18114 I ET -HP Adhesive Anchor for concrete 14 SfHIA Hurricane Tie 2 GAC. GDP, GDPM-50, GDPl GORM-100, GDPS, GW-50, GW-75, OW-100, GTH Gas -actuated fasteners and assemblies 15 S/HDSS, SfHC)8B, SIl Sil�DIOB, S!HDISS, SIHD1513 Holdowns 3 PDPA, PDPA-K, PDPA-MG, POPAT, PDPAT-K, PINW, PINWP, PINWP-W, PDPAWL, Powder -actuated fasteners threaded studs, and assemblies 16 SMDU4, SfHDUO, S1HDU9, S1HDU1 I Holdowns PDPAWL-MG, PSVL3, PSVL3-K. POLDPA, PECLOPA, PTRHA3, PTRHA4 IT SfJCT, S/HJCT Joist Hangers 4 SET-3G Adhesive Anchor for concrete -6-0 (D 0) -Cu > 0-1- C D IF- (D Cl) CD- Q_ 0 CU CD -6-, U) CD -1.-0 0 0 CU C:) - CU 0 CIO 0 0 =,- CU LL- ,- 0 CU > M Cn -0 a) U) E C (D -0-i CU "0 am. U) C:) < Z Z W mi Cin CIO 0 -4--a CIO cm) C/) _tf -6., 0 C_ U) CC 0 L_ CL CL < 2- U) ICU Cn LU Z _J a - SHEET NO. PA 1.2 ri f r