Loading...
HomeMy WebLinkAbout4626 Krusen FieldI NMI I 1 fl, ry, q, ry. ry n­ Al I A'- r (T' r S, N' IN n'. MAXIMUM 1/4" STEP FROM INTERIOR FINISH FLOOR OF BUILDING TO CORRIDOR AND ALL SIDE WALK AREAS 3" THICK CONCRETE POURED COUNTER if 110111 TOP AND EDGES TO BE POLISHED AND ROOM FINISH SCHEDULE FLOOR PLAN 1/4 SEALED TO ALLOW FOR SAFE FOOD ROLL UP DOOR CONTACT ROOM INTERIOR WALLS BLOCK WALLS CEILING FLOOR 2 LAYERS GALV STUCCO WIRE LATH 1 " FROM TOP AND 1 " FROM 3 5/8" STEEL STUD WITH 1/2" DURA ROCK STRUCK BLOCK WALLS BOTTOM OF CONCRETE COUNTER CONCESSION 48" ABOVE FINISH FLOOR AND 1/2" GYPSUM PAINTED, ONE COAT PRIMER 1/2" CEILING GYPSUM KNOCK DOWN FINISH CONCRETE POUR PAINTED ONE COAT ALKYD PRIMER SEALER PRO INDUSTRIAL PRE CATALYZED ----------- ------- ---------- TO CEILING IF PAINTED ONE COAT ALKYD PRIMER SEALER SEALER LATEX, TWO COATS ALKYD TWO COATS ALKYD ENAMEL LATEX SEMI GLOSS WATER BASE EPDXY GRAY COLOR MEETING ROOM ENAMEL LATEX SEMI GLOSS SHERWIN WILLIAMS SLIP RESISTANT ADDITIVE ClTV07ZfYff ARIL TWO COATS ALKYD ENAMEL LATEX SEMI GLOSS SHERWIN WILLIAMS SHERWIN WILLIAMS Cl SHERWIN WILLIAMS i WILDING OFFICIAL 110" 1- 4" RESTROOM N/A STRUCK BLOCK WALLS PAINTED, ONE COAT PRIMER SEALER LATEX, TWO COATS ALKYD ENAMEL LATEX SEMI GLOSS SHERWIN WILLIAMS 1/2" CEILING GYPSUM KNOCK DOWN FINISH PAINTED ONE COAT ALKYD PRIMER SEALER TWO COATS ALKYD ENAMEL LATEX SEMI GLOSS SHERWIN WILLIAMS QUARRY 6"X6"XI/2" TILE AMERICAN OLEAN Q03 SAHARA WITH ABRASIVE GRAIN SLIP RESISTANT SURFACE. GROUT COLOR SILVER OR EQUAL 3 5/8" STEEL STUD WITH 5/8" Tl -11 PINE STRUCK BLOCK WALLS 1/2" BC PINE PLYWOOD CONCRETE STORAGE SIDING TO CEILING PAINTED, ONE COAT PRIMER PAINTED ONE COAT ALKYD PRIMER SEALER PRO INDUSTRIAL PRE CATALYZED ROOMS PAINTED ONE COAT ALKYD PRIMER SEALER SEALER LATEX, TWO COATS ALKYD TWO COATS ALKYD ENAMEL LATEX SEMI GLOSS WATER BASE EPDXY GRAY COLOR TWO COATS ALKYD ENAMEL LATEX SEMI GLOSS ENAMEL LATEX SEMI GLOSS SHERWIN WILLIAMS SHERWIN WILLIAMS SHERWIN WILLIAMS SHERWIN WILLIAMS DECORATIVE CEMENTITIOUS FINISH 8" SPLIT FACE BLOCK RESTROOM CORRIDOR N/A PAINTED, ONE COAT PRIMER lX4 #2 SPRUCE @ 16"OC ATTACHED TO BOTTOM OF TRUSSES WITH 2-8D NAIL CONCRETE BROOM FINISH SEALER LATEX, TWO COATS ALKYD VINYL VENTED SOFFIT CEILING SIDE WALK ENAMEL LATEX SEMI GLOSS SHERWIN WILLIAMS AS SHOWN ON ELEVATIONS DECORATIVE CEMENTITIOUS FINISH 8" SPLIT FACE BLOCK EXTERIOR PAINTED, ONE COAT PRIMER BLOCK WALLS SEALER LATEX, TWO COATS ALKYD ENAMEL LATEX SEMI GLOSS SHERWIN WILLIAMS AS SHOWN ON ELEVATIONS EXTERIOR OME ONE COAT ZINC CHROMATE PRIMER STEEL DOORS I TWO COATS ALKYD ENAMEL SEMI GLOSS EXTERIOR OPENING SCHEDULE SCHLAGE 6 PIN SATIN CHROME LEVER KEY LdCK LOW BUMPER THRESHOLD A 3'0"X710.1 FLUSH HOLLOW METAL 3- 415 BB SATIN CHkOME HINGES AMWELD OR EQUAL WELDED METAL FRAME STAIN KICK PLATES EACH SIDE OFDOORS HEAVY DUTY DOOR CLOSURES ROLL UP GARAGE DOOR B 8'0"X7'0" OVER HEAD DOOR CORP N/A EXTERIOR KEY LOCK SYSTEM OR EQUAL ROLL UP BAR COUNTER DOOR C 8'0"X4'0" OVER HEAD DOOR CORP N/A INTERIOR KEY LOCK SYSTEM OR EQUAL CHAIN LINK BY PASS GATE UNIT 4'0"X8'0" FIXED PANEL / 4'0'X8'0" SLIDING GATE N/A LOCK SYSTEM TO BE D FIELD MEASURE AND VERIFY OPENING COORDINATE WITH OWNER BLACK PVC COATED FENCING WITH BLACK HARDWARE 24"X32" CONCRETE FIXED LOUVER E ATLANTIC COAST PRECAST 520 NE 34TH STREET NIA NIA OAKLAND PARK, FL 33334 954-564-6245 LIGHT GAUGE 3 5/8" STEEL TRACK SECURED TO STUDS WITH #8Xl/2" DWS AT EACH SIDE. SECURE TRACK TO WOOD TRUSS OR WOOD BLOCKING WITH #8XV DWS OPENING SOLID SYNTHETIC SURFACE COUNTER WITH SEAM IN CENTER OF WALL OR TO BE CHOSEN BY THE CITY OF -IYRHILLS EQUALLY SPACE 1/4"Xl 1/2"WIDE STEEL ANGL TH 16" LEG EACH WAY BELOW COUNTER TO PPORT TOP. SECURE TO STEEL STUDS AS ,EDED T GAUGE 3 5/8" STEEL STUDS @ 16" OC IT GAUGE 3 5/8" STEEL TRACK SECURED ;TUDS WITH #8Xl/2" DWS AT EACH SIDE. URE TRACK TO SLAB WITH 1 "SHOT PINS PASS THRU WALL (cD- CONCESSION AREA NOT TO SCALE 00 N TYPICAL CONCESSION PASS THRU COUNTER DETAIL NOT TO SCALE :,HT GAUGE 3 5/8" STEEL TRACK SECURED STUDS WITH #8X1/2" DWS AT EACH SIDE. CURE TRACK TO WOOD TRUSS OR WOOD OCKING WITH #8Xl" DWS TU D PACK AT EACH END OF 2'TALL WALL TO BRACE WALL IX6 PAINTED COMPOSITE CAP AT TOP OF WALL .IGHT GAUGE 3 5/8" STEEL TRACK SECURED -0 STUDS WITH #8X1/2" DWS AT EACH SIDE. =_E ROOM FII"41SH SCHEDULE FOR WALL COVERING _IGHT GAUGE 3 5/8" STEEL STUDS @ 16" OC GHT GAUGE 3 5/8" STEEL TRACK SECURED ) STUDS WITH #8Xl/2" DWS AT EACH SIDE. :-:CURE TRACK TO SLAB WITH V SHOT PINS SHORT WALL (d)- CONCESSION AREA NOT TO SCALE Q) :;3 Q) 6 N x o Q) u- m Z Q) c Q) u- r- Z Q) co Q) -p Q) to Lu (3 :3 Cj 9) S_ omca-g Q) U, \D LL Q) cu co cr) < z 0 c:) 0 cl� U) c:) w rl_ 00 cy) co C6 75 z c:) 6i d z 0 3 / /0 ( I U) IGE 3 5/8" STEEL TRACK SECURED TO STUDS /2" DWS AT EACH SIDE, SECURE TRACK TO JSS OR WOOD BLOCKING WITH #8Xl " DWS ui N LL ,UGE 3 5/8" STEEL STUDS @ 16" OC 0 F_ M FINISH SCHEDULE FOR WALL COVERING LIGE 3 5/8" STEEL TRACK SECURED TO STUDS 1/2" DWS AT EACH SIDE. SECURE TRACK TO rH V SHOT PINS RKAY ENGINEERING INC. RKAN FULL INTERIOR WALL SECTION UCTURAL ENGINEERS NOT TO SCALE RI D L. KIDDEY P.E. FLORIDA LICENSE NUMBER 37296 1 HERBY CERTIFY THAT THESE PLANS AND SPECIFICATIONS WERE PREPARED BY ME OR UNDER MY DIRECT SUPERVISION ARE IN COMPLIANCE WITH CHAPTER 16, SECTION 1609 OF THE FLORIDA BUILDING CODE 2017 6TH EDITION AND ASCE 7-10 FOR 139 MPH WIND ZONE RISK CATEGORY 11 Ali (D z 0 z 0 U) U) w z 0 C) 0 _j w LL z III cf) ct v ARKAY 17996 t- 7/8" STUCCO FINISH OVER I- "t & GALV PAPER BACK WIRE LATH it) cq (p 7/8"STUCCO FINISH OVER OVER FRAME CONSTRUCTION %D C,4 GALV PAPER BACK WIRE LATH r- ca cf) OVER FRAME CONSTRUCTION R METAL ROOF PANELS In COLORED PBR METAL ROOF PANELS COLORED PB 12 12 4 c', 4 [ . . . I . .. ... .. ... .. ... .. .. .. ... . ... .. ... .. ... .. ... .. .. to U X N:] LL_ 'a z --o (u .. .. ... .. ... .. .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. 9'4' WALL HEIGHT - - �o � . ........... _ --------- ------------------------------------------------------------- ------------- I ------------------------------------------------------------ -WALLHEIGHT 9'4" ------------------------------- --------- ------ - ---------------------------------- --------------------------- -------------- .. .. ... .. ... .. ... .. z Q) .. .. ... .. ... .. ... .. .. .. ... .. ... .. ... .. ... .. ... .. .. i� c: Q) U- 4' 0" 4- 0" -9 L 4'0" 4'0" tu to . .. . .. . .. . .. . .. . .. . .. . .. . .. . Lu —1 Q) Z Q) , Z TO'CANTILEVER WITH 12"OVERHANG Q) 37CANTILEVER WITH 12" OVERHANG AT NORTH AND SOUTH AREA ROOFS \�-L'DEC'O'R*ATIV'E'CEM'E'N*TITIO*U'SFI'N'IS'H--*-.'-\ DECORATIVE CEMENTITIOUS FINISH' AT NORTH AND SOUTH AREA ROOFS z tu Lu . ... .. ... ... .. ... .. ... .. ... .. ... .. .. .. ... .. ... .. ... .. ... .. ... .. ... FORMED CONCRETE COUNTER (J 1101, TOP, SEE DETAIL SHEET 131 'a 3 .. .. ... .. ... .. ... .. ... .. ... .. ... Q) .. .. ... .. ... ... .. ... . ... .. ... .. ... .. ... .. .. .. ... ..... ... tu vo t:.:;,: f:,: f 1:,: f�: f T FACE ta BLOCK� Q) co BUILDING FINISH FLOOR ASSUMED 0' 0" SPLIT FACE BLOC ASSUMED 0'0" FINISH FLOOR BUILDING Q_A w EAST ELEVATION 1/411 11 off WEST ELEVATION 1/41111 11 Oil . SOUTH ELEVATION 1/411 = 1 1 off NORTH ELEVATION 1/411 = 19 Oil ARKAY ENGINEERING INC. STRUCTURAL ENGINEERS RICHARD L. KIDDEY P.E. FLORIDA LICENSE NUMBER 37296 I HERBY CERTIFY THAT THESE PLANS AND SPECIFICATIONS WERE PREPARED BY ME OR UNDER MY DIRECT SUPERVISION ARE IN COMPLIANCE WITH CHAPTER 16, SECTION 1609 OF THE FLORIDA BUILDING CODE 2017 6TH EDITION AND ASCE 7-10 FOR 139 MPH WIND ZONE RISK CATEGORY 11 co 0') z 1,� A 0 c:) c:) A > c:) w elf 00 CIS z C) < 0 z 03 (D z r) _j Z U) LL1 Ld z N 0 U- 0 00 I F_ LU C) LL z Li U) ARKAY 17996 C' n" LINTELS ON THIS PROJECT ARE AS SPECIFIED ON THIS CHART UNLESS NOTED ON FLOOR PLAN BY OPENING LINTEL LOAD CHART ( 16" DEEP SECTION) CLEAR SPAN CONCRETE U LINTEL 11-61, 4987 PLF (UNFILLED) 2' - 2" 3435 PLF ( UNFILLED 2' - 8" 2777 PLF (UNFILLED 3'- 2" 2332 PLF ( UNFILLED 4'- 0" 1835 PLF (UNFILLED) 4' - 6" 1624 PLF (UNFILLED) 5' - 2" 2739 PLF 6- - 2" 2271 PLF 7' - 0" 1987 PLF 81-01, 1723 PLF 9'- 2" 1489 PLF 101-01, 1354 PLF DENOTES #5 REBARX CONT. PLACED IN BOTTOM COURSE AND 16" DEEP BEAM POURED SOLID WITH 2500 PSI CONCRETE. P - DENOTES PRE STRESSED U LINTEL WITH #5 REBAR X CONT. PLACED IN BOTTOM COURSE & 16" DEEP BEAM POURED SOLID WITH 2500 PSI CONCRETE 8" X 8" X 16" KNOCK OUT BLOCK TOP COARSE WITH 1 #5 HORIZONTAL REBAR TIED TO ALL VERTICAL RODS 8" ...... .. ......... . . .. ... .... 8" PRECAST LINTEL BLOCK OVERALL OPENINGS. 1 EACH 7--.7 U-�- #5 REBAR IN THIS COARSE WHEN SPAN OF LINTEL OVER 5'2" STANDARD PRECAST DETAIL NOT TO SCALE 1/2" CDX PLYWOOD NAILED PER ROOF SHEATHING DETAIL. COVER WITH GAF UNDERLAYMENT AND PBR ROOF PANELS INSTALLED PER MANUFACTURE 2X4 PT LEDGER ATTACH TO FACE OF BLOCK WALL WITH 1/4"X3 1/4" TAP CONS 12" OC TOE NAIL 2X4 #2 SPRUCE TO 2X4 WITH 2-12D NAILS 2X4 #2 SPRUCE BLOCKING FROM FACE OF EACH ROOF TRUSS AND WILL EXTEND BACK TO FACE OF BLOCK WALL. 36'8" 8'0" 36'8" SIDE WALK EDGE SIDE WALK EDGE C� 19,01, LD or m 211 \mr [N Jq -- m . . . . . — — — — — — — — — — — — — ----------------------------------------------------------------------------------- F -I- ---------------- . . . . — — — — — — — — — — — — — — — — - I --------------------------------------------------------------------------------------------------- I [Al cl) 7'6Ya" 7'6Ys" cr) cn uj ui w Ld C) 04 C) C14 "S"��C) a C) cl) Lu cn :T FAI cl) ----------------------------------------------------------------------------—------- ---------------- --—--------------- ---- —----------------—----------------------------------------------------—-------- \0 L - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Lo -m-k F81 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ET Tw- i (TOF m 0 m 0 m m #5 VERTICAL RODS FROM FOOTINGS ELOW TO TOP OF WALL. PLACED AT 4- 4" B.O.. 6' 8", 8' 0" ALL CORNERS, EACH SIDE OF ALL 3'4" 24' 8" OPENINGS AND SPACED MAXIMUM 4'0"OC SIDE WALK EDGE SIDE WALK EDGE C-5- 0" 36'8" 8' 0" 36'8" 5-0" 91'4" 12 ENGINEERED ROOF TRUSSES R-30 FIBERGLASS INSULATION IN ALL ATTIC AREAS SEE PLUMBING FIXTURE LOCATION PLAN PRIOR TO POURING SLAB TO LOCATE FIXTURES AND ELECTRICAL CONDUITS IN SLAB FOUNDATION PLAN 1/411 = 11 off HATCHED CONCRETE AREAS DENOTE MAXIMUM 1/4" STEP FROM INTERIOR FINISH FLOOR OF BUILDING ] t— t—'T \D %'D In LU Q) ct) \D:;-, M 6 x j-L- ` Z Qj — U4 Q) Q) Z' Qj co Z IU uj CIS 70 MiT-1 tu \Q Qc- ul Q) 93 w co 0) z c:) c:) 0 A C/) C:) LU I, - T— L6 T— co It CIS T— 2 L6 z 0 b z 0 L Is ZD 3-12D NAILS TO FACE OF TRUSS Z 0 9'4" WALL HEIGHT 7- ry U) ALUMINUM EAVE DRIP SEE ROOM FINISH SCHEDULE w 2X4 #2 SPRUCE SUB FASCIA 3'0" SEE ROOM FINISH SCHEDULE WITH ALUMINUM FASCIA SINGLE ROW KNOCK OUT LINTEL BLOCK WITH w z VINYL VENTED SOFFIT TO" CANTILEVER WITH 12" OVERHANG 145 HORIZONTAL REBAR TIED TO ALL VERTICAL SINGLE ROW KNOCK OUT LINTEL BLOCK WITH N 0 AT NORTH AND SOUTH AREA ROOFS RODS AND POURED SOLID WITH 2500 PSI CONCRETE 145 HORIZONTAL REBAR TIED TO ALL VERTICAL U RODS AND POURED SOLID WITH 2500 PSI CONCRETE LL 0 8" PRECAST LINTEL OVER ALL OPENINGS 8" PRECAST LINTEL OVER ALL OPENINGS t u- 8" MASONRY BLOCK WALLS WITH z DECORATIVE CEMENTITIOUS FINISH SEE ROOM FINISH SCHEDULE w SEE ROOM FINISH SCHEDULE 1 X4 #2 SPRUCE @ 16" OC ATTACHED BOTTOM OF TRUSSES WITH 2-8D NAIL TO U) FOAM FILL ALL CELLS OF BLOCK VINYL VENTED SOFFIT CEILING WALL NOT FILLED WITH CONCRETE It FOAM FILL ALL CELLS OF BLOCK WALL NOT FILLED WITH CONCRETE 4 COARSE 8" MASONRY SPLIT FACE BLOCK SIDE WALK TO BE MAXIMUM 1/4" BELOW BUILDING FINISH FLOOR BUILDING ASSUMED 0'0" FINISH FLOOR #5 VERTICAL REBAR AT THE LOCATIONS SHOWN ON FLOOR PLAN 00 N BOTTOM OF FOUNDATION 1- 4" MINIMUM 12" BELOW GRADE -1 2500 PSI CONCRETE OVER 6/6 10/10 WIRE MESH 6 MILL VISQUEEN AND CLEAN COMPACT TERMITE TREATED SOIL SEE ROOM FINISH SCHEDULE 16"X16" MONO FOOT!NG WITH 345 REBAR ON CHAIRS AT THE ON FLOOR 500 PSI CONCRETE OVER 6/6 10/10 WIRE MESH MILL VISQUEEN AND CLEAN COMPACT TERMITE REATED SOIL OM FINISH SCHEDULE DOTING D t-)Kl rWAID(Z — I 1 1 —v lx— CORRIDOR SECTION DETAIL NOT TO SCALE ARKAY ENGINEERING INC. STRUCTURAL ENGINEERS RICHARD L. KIDDEY P.E. FLORIDA LICENSE NUMBER 37296 I HERBY CERTIFY THAT THESE PLANS AND SPECIFICATIONS WERE PREPARED BY ME OR UNDER MY DIRECT SUPERVISION ARE IN COMPLIANCE WITH CHAPTER 16, SECTION 1609 OF THE FLORIDA BUILDING CODE 2017 6TH EDITION AND ASCE 7-10 FOR 139 MPH WIND ZONE RISK CATEGORY 11 BUILDING CUT SECTION DETAIL NOT TO SCALE INTERIOR BLOCK WALL SECTION DETAIL NOT TO SCALE ARKAY 17996 ELECTRICAL LEGEND & FIXTURE SCHEDULE G.F.I. 110V LITHONIA WALL PACK LIGHTING SWITCH GROUND FAULT TWH LED ALO 40K 70 WAT OR S (b RECEPTACLE EQUAL TIMER CONTROLED oc OCCUPANCY SENOR (b 1110V WP 110V (D WATERPROOF OUTLET 4=A 110VQUAD GF GROUND FAULT I" RECEPTACLE ELECTRICAL PANEL 11 OV 180 CFM'S BROAN NUTONE 505 BATH FAN METER +52" HUNTER MODEL 53323 INDOOR SMOKE ALARM OUTDOOR BRONZE CEILING FAN WITH BATTERY NO LIGHT KIT S BACK UP LITHONIA LIGHTING FMLWL LED WRAP SURFACE MOUNT FIXTURE 40.77 W 2900 LM OR EQUAL ELECTRICAL NOTES LITHONIA LIGHTING XVML LED VAPOR TIGHT SURFACE MOUNT FIXTURE 33 W 3500 LM OR EQUAL 1. All work to be done in accordance with all current national and local codes and ordinances. 2. Notify Engineer of any discrepancies between these drawings and the actual field conditions. Obtain clarifications from the Engineer or Owners prior to commencing work. 3. Contractor will visit site prior to bidding, no allowances for any extra expenses will be granted as a result of not visiting site. 4. Wire to be THHN/THWN Copper, min. size 14 AWG, unless shown otherwise. 5. RACEWAYS: RIGID STEEL CONDUIT: full weight galvanized threaded pipe, EMT CONDUIT: compression fittings, PVC: schedule 40, all as allowed by local codes. Seperate raceways shall be used for each voltage system. 6. Any installation conflict with other trades shall be brought to the attention of the Engineer for clarification before proceeding. 7. Contractor will verify location of equipment and connect as required for clearances and connections. 8. All ourdoor electrical equipment to be NEMA 3R rated. CONDUIT TO BE EXPOSED FLUSH MOUNT ON FACE OF INTERIOR BLOCK WALLS ELECTRICAL SPECIFICATIONS 1.1 SCOPE A. WORK INCLUDED: Include the following Work in addition to items normally part of this Section: 01 Wiring for lighting and power. 02 Installation of lighting fixtures with lamps. 03 Lighting panelboards and distribution panelboards. 04 Connection of equipment shown. 05 Control wiring. 06 Disconnection and removal of existing fixtures and wiring not to be reused. 1.2 MINIMUM COMPLIANCE STANDARDS A. All work shall be done in accordance with the requirements of the following: 01 Latest adopted issue of the National Electrical Code, NFPA 70. 02 Other applicable NFPA Codes. 03 Regulation of local authorities having jurisdiction. B. Furnish and install all labor, material and equipment and services necessary for complete and safe installation of the electrical system indicated on the drawings and noted in the specifications hereinafter. Electrical systems and equipment shall in general include the following: 01 General provisions for electrical work. 02 Wiring, distribution equipment and devices. 03 Lighting fixtures and lamps. 04 Grounding system. 1.3 GENERAL PROVISIONS FOR ELECTRICAL WORK A. DRAWINGS: Electrical drawings considered diagrammatic and indicate general arrangement of work and systems. Refer to other drawings to verify location of equipment, etc. Check drawings of other trades to verify exact space condition or underground lines. Drawing Scales prohibit the indication of all offsets, fittings and accessories required, however these items will be provided by this subcontractor at no extra cost to the owner. B. QUALITY OF MATERIALS: New, best of their respective kind, free from defects, and listed by Underwriter's Laboratories, Inc. or bearing their label. C. SHOP DRAWINGS: Submit four (4) copies of shop drawings for lighting fixtures and panelboards. Obtain approval before equipment is ordered, built or installed. D. EXCAVATION AND BACKFILLING: Excavate, backfill and restore surfaces for all electrical work. E. Visit site and inspect existing facilities before bid in order to ensure proper evaluation of working conditions and location of existing equipment. 1.4 WIRING, DISTRIBUTION EQUIPMENT AND DEVICES A. CONDUCTORS: Copper, in accordance with ASTM Standards, size references AWG. Conductors No. 10 and smaller size solid, No. 8 and larger stranded. Insulation of conductor thermoplastic, type THHN (min. size: No. 12) any wire installed outside, underground, in slabs, or exposed to moisture shall have THWN insulation. B. RACEWAYS: RIGID STEEL CONDUIT, full weight pipe galvanized, threaded, and minimum 1/2 inch except as noted or required for wiring. ELECTRICAL METALLIC TUBING (EMT), thin wall pipe, galvanized, threadless, comiression fittings, and minimum 1/2" except as noted or required for wiring. FLEXIBLE STEEL CONDUIT, continuous singlestrip, galvanized, and minimum 1/2" size except as noted or required for wiring. PVC CONDUIT, heavy duty type, size as indicated. Type AC or MC cable where permitted. Separate raceways shall be used for each voltage system. C. DISCONNECT SWITCHES: General Duty, horsepower rated for motor loads 600 or 250 volt rating, fused or non -fused as noted; number of poles as indicated, cover interlocked with switch. Enclosure NEMA 1 for indoor use and NEMA 3R for weatherproof applications. Switch to be Square "D" or equal. D. CIRCUIT BREAKERS: Molded case, thermal -magnetic quick -make, quick -break, bolt -on type with manually operated insulated trip -free handle. Multi -pole types with internal common trip bar. Terminals suitable for copper or aluminum conductors. Interrupting capacity minimum 10,000 RMS symmetrical amperes circuit breakers to be Square "D" or equal, type as required. E. PANELBOARDS: Voltage, phasing and ampere ratings as indicated, circuit breaker type as indicated, busbars of hard drawn copper, minimum 98% conductivity, galvanized steel back box, door and trim. All corners lapped and welded, hardware chrome plated with flush lock and catch. Hinges semi - concealed, 5 knuckle steel with nonferrous pins, 180 degree openings. Minimum gutter space 5- 3/4" sides, top and bottom. Increase size where required by code. Directory holder complete with clear plastic transparent cover indicating typewritten list of feeder cables, conduit sizes, circuit numbers, outlets of equipment supplied, and their location. Circuit breaker type panelboards to be Square "D" type NQOD or I -Line, or equal. A plastic label shall be located on exterior of panelboard identifying the system voltage, phase, and current rating. F. WIRING DEVICES: All devices the product of the same manufacturer. Wall switches sin le pole, 20 _g ampere, 120 volt. Wall switches three-way, 20 ampere, 120 volt. Receptacles duplex, 2 wire; 3 pole grounded, 20 ampere, 120 volt. G. DEVICE PLATES: Provide for all outlets where devices are installed. Provide engraved marking for special outlets. Provide blank plates for empty or future outlet boxes. DEVICE AND DEVICE PLATES COLORS TO BE VERIFIED WITH INTERIOR DESIGNER AND OWNER. 1.5 LIGHTING FIXTURES AND LAMPS A. Furnish and install complete system of lighting fixtures, lamps, accessories and supports as specified and indicated. Submittals of equal quality are allowed. 1.6 GROUNDING SYSTEM A. EQUIPMENT: Ground non -current carrying metal parts of panelboard, raceways and all lighting fixtures. All conduits shall have equipment grounding conductors. 1.7 INSTALLATION A. Secure all supports to building structure. Support horizontal runs of metallic conduit not more than 10 feet apart. Run exposed raceways parallel with or at right angles to walls. B. Pass raceways over water, steam or other piping when pull boxes are not required. No raceway within 3 inches of steam or hot water pipes, or appliances, except crossings where raceway shall be at least 2 inches from pipe cover. C. Cut conduit ends square, ream smooth. Paint male threads of field threaded conduit with graphite base pipe compound. Draw up tight with conduit couplings. D. Leave wire sufficiently long to permit making final connections. In raceways over 50 feet in which wiring is not installed, furnish pull wire. E. Verify locations of outlets and switches. F. Support panel, junction and pull boxes independently to building structure with no weight bearing on conduits. G. Connect conduit to motor conduit terminal boxes with flexible conduit; minimum 18 inches in length and 50% slack. Do not terminate in or fasten raceways to motor foundation. H. Contractor to remove and salvage all abandoned electrical equiment. 1. This contractor shall warrant all labor and materials for one year from date of final written acceptance. ELECTRICAL PLAN 1/491 = 1 1 off 200 AMP 30 CIRC PANEL 1 DED CIRCUIT I P2o 2 DED CIRCUIT 1 P20 3 DED CIRCUIT I P20 4 DED CIRCUIT 1 P20 5 DED CIRCUIT 1 P20 6 DED CIRCUIT 1 P20 7 DED CIRCUIT 1 P20 8 DED CIRCUIT 1 P20 9 DED CIRCUIT 1 P20 1 10 DED CIRCUIT 1 P20 11 DED CIRCUIT 1 P20 12 DED CIRCUIT 1 P20 13 DED CIRCUIT I P20 14 DED CIRCUIT 1 P20 15 DED CIRCUIT 1 P20 16 DED CIRCUIT 1 P20 17 CONCESSION LIGHTS/SMOKE ALARM 1 P20 18 EMERGENCY EIXT COMBO 1 P20 19 EQUIP STORAGE &WATER FOUNTAIN 1 P20 20 WOMENS RESTROOM LIGHTS 1 P20 21 RESTROOM GFI OUTLETS 1 P20 22 RESTROOM HAND DRYERS 1 P20 23 MENS RESTROOM LIGHTS 1 P20 24 STORAGE LIGHT 1 P20 25 OUTDOOR LIGHTS TIMER 1 P20 26 WATER HEATER 2P40 271 OPEN 28 1 1 291 MEETING ROOM LIGHTS/OUTLETS 1P20 . 30 1 MINI SPLIT UNIT I BUILDING LOAD CALCULATIONS LOAD DESCRIPTION DEMAND FACTOR TOTALS LIGHTING 1952 VA X 3 5856 VA RECEPTACLES ALLOWANCE 40 @ 180VA 7200 VA WATER HEATER 4500 VA TOTAL VA 17556 VA 17556 74 AMPS 240 TYPICAL ELECTRICAL RISER DIAGRAM 3 - 4/0 ALUMN 2" GALV RISER METER SOCKET GROUND PER N.E.C. 2- 4/0 #6 GROUND 2" GALV NIPPLE CONCRETE ENCASED "LIFER" ELECTRODE REQUIRED PER CURRENT N.E.C. AND MUST BE INSPECTED PRIOR TO CONCRETE PLACEMENT ARKAY ENGINEERING INC. STRUCTURAL ENGINEERS RICHARD L. KIDDEY P.E. FLORIDA LICENSE NUMBER 37296 I HERBY CERTIFY THAT THESE PLANS AND SPECIFICATIONS WERE PREPARED BY ME OR UNDER MY DIRECT SUPERVISION ARE IN COMPLIANCE WITH CHAPTER 16, SECTION 1609 OF THE FLORIDA BUILDING CODE 2017 6TH EDITION AND ASCE 7-10 FOR 139 MPH WIND ZONE RISK CATEGORY 11 CZ lu 01 0 * Cq "o * Z Q) cil %D Q) C() M 19 0 X.N -1 W U_ b M L_ %5 Q) LU C Z Q) W 4_1 s- Q) tu Ot fJ Q) 10 6i < C) Z JCb I A 0 C) LD I cf) W rl- co 00 00 L6 Ob L6 Z 0 bi Z I-- co < 0 (D Z Z 0 0 W LIJ CL Z Ili N 0 U_ 0 00 Z W U) D E 1 ARKAY 17996 MOUNT EACH UNIT 7'4" A.F.F. PIONEER MINI SPLIT SYSTEM MODEL WYS009AMFI 17RL -14-0��iT�U�;0--12.dVTPR-lf-SE-ER - - - - - - - - - - - - - - - - - - - - - - 7 — — — — — — — — — — — -=7= :1- — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — - — — -- — — — — — — 250 _350 SQ FT. CAPACITY 25 1 METER I THt FEM- — ------------------------- TD 25 200 A P T.C. ELEC N — 48" STORAGE — — 30 SHELVES 36" STORAGE — 18 TIT L WATER — E� SHELVES — 63" COM DE =_P FREEZER REFRIG K =1 L36- iEATER — 30" ICE 7 IKO 22 28 — MACHINE ri 20 19 29 18 E=- GF HAND DRYER 443 22 19 2 30" STORAGE U 16 X SHELVES 4a 14,22 UJ 9 1 19 r LU 1 18- 29� 0][ 23 C 17 18 0 17 C) 15 0"5 R3 18 19-4 0 14 12 10 21 0i X LU TAVL WALL 2:;L X LLI 17 F` 30" ICE MACHINE T 18 8 6 4 36" STORAJ SHELVES 48" STORAGE 36" R�FFRIG 63" COM D�P FREEZER \Irq 0- O_ :� 0=1C)_1 F 7 7717,17 7 ------------------------ A MV L L----------- --------- --------------------------- ---------------------------------- ---------------------------- --------------- J ELECTRICAL SPECIFICATIONS 1.1 SCOPE A. WORK INCLUDED: Include the following Work in addition to items normally part of this Section: 01 Wiring for lighting and power. 02 Installation of lighting fixtures with lamps. 03 Lighting panelboards and distribution panelboards. 04 Connection of equipment shown. 05 Control wiring. 06 Disconnection and removal of existing fixtures and wiring not to be reused. 1.2 MINIMUM COMPLIANCE STANDARDS A. All work shall be done in accordance with the requirements of the following: 01 Latest adopted issue of the National Electrical Code, NFPA 70. 02 Other applicable NFPA Codes. 03 Regulation of local authorities having jurisdiction. B. Furnish and install all labor, material and equipment and services necessary for complete and safe installation of the electrical system indicated on the drawings and noted in the specifications hereinafter. Electrical systems and equipment shall in general include the following: 01 General provisions for electrical work. 02 Wiring, distribution equipment and devices. 03 Lighting fixtures and lamps. 04 Grounding system. 1.3 GENERAL PROVISIONS FOR ELECTRICAL WORK A. DRAWINGS: Electrical drawings considered diagrammatic and indicate general arrangement of work and systems. Refer to other drawings to verify location of equipment, etc. Check drawings of other trades to verify exact space condition or underground lines. Drawing Scales prohibit the indication of all offsets, fittings and accessories required, however these items will be provided by this subcontractor at no extra cost to the owner. B. QUALITY OF MATERIALS: New, best of their respective kind, free from defects, and listed by Underwriter's Laboratories, Inc. or bearing their label. C. SHOP DRAWINGS: Submit four (4) copies of shop drawings for lighting fixtures and panelboards. Obtain approval before equipment is ordered, built or installed. D. EXCAVATION AND BACKFILLING: Excavate, backfill and restore surfaces for all electrical work. E. Visit site and inspect existing facilities before bid in order to ensure proper evaluation of working conditions and location of existing equipment. 1.4 WIRING, DISTRIBUTION EQUIPMENT AND DEVICES A. CONDUCTORS: Copper, in accordance with ASTM Standards, size references AWG. Conductors No. 10 and smaller size solid, No. 8 and larger stranded. Insulation of conductor thermoplastic, type THHN (min. size: No. 12) any wire installed outside, underground, in slabs, or exposed to moisture shall have THWN insulation. B. RACEWAYS: RIGID STEEL CONDUIT, full weight pipe galvanized, threaded, and minimum 1/2 inch except as noted or required for wiring. ELECTRICAL METALLIC TUBING (EMT), thin wall pipe, galvanized, threadless, comiression fittings, and minimum 1/2" except as noted or required for wiring. FLEXIBLE STEEL CONDUIT, continuous singlestrip, galvanized, and minimum 1/2" size except as noted or required for wiring. PVC CONDUIT, heavy duty type, size as indicated. Type AC or MC cable where permitted. Separate raceways shall be used for each voltage system. C. DISCONNECT SWITCHES: General Duty, horsepower rated for motor loads 600 or 250 volt rating, fused or non -fused as noted; number of poles as indicated, cover interlocked with switch. Enclosure NEMA 1 for indoor use and NEMA 3R for weatherproof applications. Switch to be Square "D" or equal. D. CIRCUIT BREAKERS: Molded case, thermal -magnetic quick -make, quick -break, bolt -on type with manually operated insulated trip -free handle. Multi -pole types with internal common trip bar. Terminals suitable for copper or aluminum conductors. Interrupting capacity minimum 10,000 RMS symmetrical amperes circuit breakers to be Square "D" or equal, type as required. E. PANELBOARDS: Voltage, phasing and ampere ratings as indicated, circuit breaker type as indicated, busbars of hard drawn copper, minimum 98% conductivity, galvanized steel back box, door and trim. All corners lapped and welded, hardware chrome plated with flush lock and catch. Hinges semi - concealed, 5 knuckle steel with nonferrous pins, 180 degree openings. Minimum gutter space 5- 3/4" sides, top and bottom. Increase size where required by code. Directory holder complete with clear plastic transparent cover indicating typewritten list of feeder cables, conduit sizes, circuit numbers, outlets of equipment supplied, and their location. Circuit breaker type panelboards to be Square "D" type NQOD or I -Line, or equal. A plastic label shall be located on exterior of panelboard identifying the system voltage, phase, and current rating. F. WIRING DEVICES: All devices the product of the same manufacturer. Wall switches sin le pole, 20 _g ampere, 120 volt. Wall switches three-way, 20 ampere, 120 volt. Receptacles duplex, 2 wire; 3 pole grounded, 20 ampere, 120 volt. G. DEVICE PLATES: Provide for all outlets where devices are installed. Provide engraved marking for special outlets. Provide blank plates for empty or future outlet boxes. DEVICE AND DEVICE PLATES COLORS TO BE VERIFIED WITH INTERIOR DESIGNER AND OWNER. 1.5 LIGHTING FIXTURES AND LAMPS A. Furnish and install complete system of lighting fixtures, lamps, accessories and supports as specified and indicated. Submittals of equal quality are allowed. 1.6 GROUNDING SYSTEM A. EQUIPMENT: Ground non -current carrying metal parts of panelboard, raceways and all lighting fixtures. All conduits shall have equipment grounding conductors. 1.7 INSTALLATION A. Secure all supports to building structure. Support horizontal runs of metallic conduit not more than 10 feet apart. Run exposed raceways parallel with or at right angles to walls. B. Pass raceways over water, steam or other piping when pull boxes are not required. No raceway within 3 inches of steam or hot water pipes, or appliances, except crossings where raceway shall be at least 2 inches from pipe cover. C. Cut conduit ends square, ream smooth. Paint male threads of field threaded conduit with graphite base pipe compound. Draw up tight with conduit couplings. D. Leave wire sufficiently long to permit making final connections. In raceways over 50 feet in which wiring is not installed, furnish pull wire. E. Verify locations of outlets and switches. F. Support panel, junction and pull boxes independently to building structure with no weight bearing on conduits. G. Connect conduit to motor conduit terminal boxes with flexible conduit; minimum 18 inches in length and 50% slack. Do not terminate in or fasten raceways to motor foundation. H. Contractor to remove and salvage all abandoned electrical equiment. 1. This contractor shall warrant all labor and materials for one year from date of final written acceptance. ELECTRICAL PLAN 1/491 = 1 1 off 200 AMP 30 CIRC PANEL 1 DED CIRCUIT I P2o 2 DED CIRCUIT 1 P20 3 DED CIRCUIT I P20 4 DED CIRCUIT 1 P20 5 DED CIRCUIT 1 P20 6 DED CIRCUIT 1 P20 7 DED CIRCUIT 1 P20 8 DED CIRCUIT 1 P20 9 DED CIRCUIT 1 P20 1 10 DED CIRCUIT 1 P20 11 DED CIRCUIT 1 P20 12 DED CIRCUIT 1 P20 13 DED CIRCUIT I P20 14 DED CIRCUIT 1 P20 15 DED CIRCUIT 1 P20 16 DED CIRCUIT 1 P20 17 CONCESSION LIGHTS/SMOKE ALARM 1 P20 18 EMERGENCY EIXT COMBO 1 P20 19 EQUIP STORAGE &WATER FOUNTAIN 1 P20 20 WOMENS RESTROOM LIGHTS 1 P20 21 RESTROOM GFI OUTLETS 1 P20 22 RESTROOM HAND DRYERS 1 P20 23 MENS RESTROOM LIGHTS 1 P20 24 STORAGE LIGHT 1 P20 25 OUTDOOR LIGHTS TIMER 1 P20 26 WATER HEATER 2P40 271 OPEN 28 1 1 291 MEETING ROOM LIGHTS/OUTLETS 1P20 . 30 1 MINI SPLIT UNIT I BUILDING LOAD CALCULATIONS LOAD DESCRIPTION DEMAND FACTOR TOTALS LIGHTING 1952 VA X 3 5856 VA RECEPTACLES ALLOWANCE 40 @ 180VA 7200 VA WATER HEATER 4500 VA TOTAL VA 17556 VA 17556 74 AMPS 240 TYPICAL ELECTRICAL RISER DIAGRAM 3 - 4/0 ALUMN 2" GALV RISER METER SOCKET GROUND PER N.E.C. 2- 4/0 #6 GROUND 2" GALV NIPPLE CONCRETE ENCASED "LIFER" ELECTRODE REQUIRED PER CURRENT N.E.C. AND MUST BE INSPECTED PRIOR TO CONCRETE PLACEMENT ARKAY ENGINEERING INC. STRUCTURAL ENGINEERS RICHARD L. KIDDEY P.E. FLORIDA LICENSE NUMBER 37296 I HERBY CERTIFY THAT THESE PLANS AND SPECIFICATIONS WERE PREPARED BY ME OR UNDER MY DIRECT SUPERVISION ARE IN COMPLIANCE WITH CHAPTER 16, SECTION 1609 OF THE FLORIDA BUILDING CODE 2017 6TH EDITION AND ASCE 7-10 FOR 139 MPH WIND ZONE RISK CATEGORY 11 CZ lu 01 0 * Cq "o * Z Q) cil %D Q) C() M 19 0 X.N -1 W U_ b M L_ %5 Q) LU C Z Q) W 4_1 s- Q) tu Ot fJ Q) 10 6i < C) Z JCb I A 0 C) LD I cf) W rl- co 00 00 L6 Ob L6 Z 0 bi Z I-- co < 0 (D Z Z 0 0 W LIJ CL Z Ili N 0 U_ 0 00 Z W U) D E 1 ARKAY 17996 MOUNT EACH UNIT 7'4" A.F.F. PIONEER MINI SPLIT SYSTEM MODEL WYS009AMFI 17RL -14-0��iT�U�;0--12.dVTPR-lf-SE-ER - - - - - - - - - - - - - - - - - - - - - - 7 — — — — — — — — — — — -=7= :1- — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — - — — -- — — — — — — 250 _350 SQ FT. CAPACITY 25 1 METER I THt FEM- — ------------------------- TD 25 200 A P T.C. ELEC N — 48" STORAGE — — 30 SHELVES 36" STORAGE — 18 TIT L WATER — E� SHELVES — 63" COM DE =_P FREEZER REFRIG K =1 L36- iEATER — 30" ICE 7 IKO 22 28 — MACHINE ri 20 19 29 18 E=- GF HAND DRYER 443 22 19 2 30" STORAGE U 16 X SHELVES 4a 14,22 UJ 9 1 19 r LU 1 18- 29� 0][ 23 C 17 18 0 17 C) 15 0"5 R3 18 19-4 0 14 12 10 21 0i X LU TAVL WALL 2:;L X LLI 17 F` 30" ICE MACHINE T 18 8 6 4 36" STORAJ SHELVES 48" STORAGE 36" R�FFRIG 63" COM D�P FREEZER \Irq 0- O_ :� 0=1C)_1 F 7 7717,17 7 ------------------------ A MV L L----------- --------- --------------------------- ---------------------------------- ---------------------------- --------------- J TYPICAL ELECTRICAL RISER DIAGRAM 3 - 4/0 ALUMN 2" GALV RISER METER SOCKET GROUND PER N.E.C. 2- 4/0 #6 GROUND 2" GALV NIPPLE CONCRETE ENCASED "LIFER" ELECTRODE REQUIRED PER CURRENT N.E.C. AND MUST BE INSPECTED PRIOR TO CONCRETE PLACEMENT ARKAY ENGINEERING INC. STRUCTURAL ENGINEERS RICHARD L. KIDDEY P.E. FLORIDA LICENSE NUMBER 37296 I HERBY CERTIFY THAT THESE PLANS AND SPECIFICATIONS WERE PREPARED BY ME OR UNDER MY DIRECT SUPERVISION ARE IN COMPLIANCE WITH CHAPTER 16, SECTION 1609 OF THE FLORIDA BUILDING CODE 2017 6TH EDITION AND ASCE 7-10 FOR 139 MPH WIND ZONE RISK CATEGORY 11 CZ lu 01 0 * Cq "o * Z Q) cil %D Q) C() M 19 0 X.N -1 W U_ b M L_ %5 Q) LU C Z Q) W 4_1 s- Q) tu Ot fJ Q) 10 6i < C) Z JCb I A 0 C) LD I cf) W rl- co 00 00 L6 Ob L6 Z 0 bi Z I-- co < 0 (D Z Z 0 0 W LIJ CL Z Ili N 0 U_ 0 00 Z W U) D E 1 ARKAY 17996 MOUNT EACH UNIT 7'4" A.F.F. PIONEER MINI SPLIT SYSTEM MODEL WYS009AMFI 17RL -14-0��iT�U�;0--12.dVTPR-lf-SE-ER - - - - - - - - - - - - - - - - - - - - - - 7 — — — — — — — — — — — -=7= :1- — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — - — — -- — — — — — — 250 _350 SQ FT. CAPACITY 25 1 METER I THt FEM- — ------------------------- TD 25 200 A P T.C. ELEC N — 48" STORAGE — — 30 SHELVES 36" STORAGE — 18 TIT L WATER — E� SHELVES — 63" COM DE =_P FREEZER REFRIG K =1 L36- iEATER — 30" ICE 7 IKO 22 28 — MACHINE ri 20 19 29 18 E=- GF HAND DRYER 443 22 19 2 30" STORAGE U 16 X SHELVES 4a 14,22 UJ 9 1 19 r LU 1 18- 29� 0][ 23 C 17 18 0 17 C) 15 0"5 R3 18 19-4 0 14 12 10 21 0i X LU TAVL WALL 2:;L X LLI 17 F` 30" ICE MACHINE T 18 8 6 4 36" STORAJ SHELVES 48" STORAGE 36" R�FFRIG 63" COM D�P FREEZER \Irq 0- O_ :� 0=1C)_1 F 7 7717,17 7 ------------------------ A MV L L----------- --------- --------------------------- ---------------------------------- ---------------------------- --------------- J ARKAY ENGINEERING INC. STRUCTURAL ENGINEERS RICHARD L. KIDDEY P.E. FLORIDA LICENSE NUMBER 37296 I HERBY CERTIFY THAT THESE PLANS AND SPECIFICATIONS WERE PREPARED BY ME OR UNDER MY DIRECT SUPERVISION ARE IN COMPLIANCE WITH CHAPTER 16, SECTION 1609 OF THE FLORIDA BUILDING CODE 2017 6TH EDITION AND ASCE 7-10 FOR 139 MPH WIND ZONE RISK CATEGORY 11 CZ lu 01 0 * Cq "o * Z Q) cil %D Q) C() M 19 0 X.N -1 W U_ b M L_ %5 Q) LU C Z Q) W 4_1 s- Q) tu Ot fJ Q) 10 6i < C) Z JCb I A 0 C) LD I cf) W rl- co 00 00 L6 Ob L6 Z 0 bi Z I-- co < 0 (D Z Z 0 0 W LIJ CL Z Ili N 0 U_ 0 00 Z W U) D E 1 ARKAY 17996 MOUNT EACH UNIT 7'4" A.F.F. PIONEER MINI SPLIT SYSTEM MODEL WYS009AMFI 17RL -14-0��iT�U�;0--12.dVTPR-lf-SE-ER - - - - - - - - - - - - - - - - - - - - - - 7 — — — — — — — — — — — -=7= :1- — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — - — — -- — — — — — — 250 _350 SQ FT. CAPACITY 25 1 METER I THt FEM- — ------------------------- TD 25 200 A P T.C. ELEC N — 48" STORAGE — — 30 SHELVES 36" STORAGE — 18 TIT L WATER — E� SHELVES — 63" COM DE =_P FREEZER REFRIG K =1 L36- iEATER — 30" ICE 7 IKO 22 28 — MACHINE ri 20 19 29 18 E=- GF HAND DRYER 443 22 19 2 30" STORAGE U 16 X SHELVES 4a 14,22 UJ 9 1 19 r LU 1 18- 29� 0][ 23 C 17 18 0 17 C) 15 0"5 R3 18 19-4 0 14 12 10 21 0i X LU TAVL WALL 2:;L X LLI 17 F` 30" ICE MACHINE T 18 8 6 4 36" STORAJ SHELVES 48" STORAGE 36" R�FFRIG 63" COM D�P FREEZER \Irq 0- O_ :� 0=1C)_1 F 7 7717,17 7 ------------------------ A MV L L----------- --------- --------------------------- ---------------------------------- ---------------------------- --------------- J rl- co 00 00 L6 Ob L6 Z 0 bi Z I-- co < 0 (D Z Z 0 0 W LIJ CL Z Ili N 0 U_ 0 00 Z W U) D E 1 ARKAY 17996 MOUNT EACH UNIT 7'4" A.F.F. PIONEER MINI SPLIT SYSTEM MODEL WYS009AMFI 17RL -14-0��iT�U�;0--12.dVTPR-lf-SE-ER - - - - - - - - - - - - - - - - - - - - - - 7 — — — — — — — — — — — -=7= :1- — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — - — — -- — — — — — — 250 _350 SQ FT. CAPACITY 25 1 METER I THt FEM- — ------------------------- TD 25 200 A P T.C. ELEC N — 48" STORAGE — — 30 SHELVES 36" STORAGE — 18 TIT L WATER — E� SHELVES — 63" COM DE =_P FREEZER REFRIG K =1 L36- iEATER — 30" ICE 7 IKO 22 28 — MACHINE ri 20 19 29 18 E=- GF HAND DRYER 443 22 19 2 30" STORAGE U 16 X SHELVES 4a 14,22 UJ 9 1 19 r LU 1 18- 29� 0][ 23 C 17 18 0 17 C) 15 0"5 R3 18 19-4 0 14 12 10 21 0i X LU TAVL WALL 2:;L X LLI 17 F` 30" ICE MACHINE T 18 8 6 4 36" STORAJ SHELVES 48" STORAGE 36" R�FFRIG 63" COM D�P FREEZER \Irq 0- O_ :� 0=1C)_1 F 7 7717,17 7 ------------------------ A MV L L----------- --------- --------------------------- ---------------------------------- ---------------------------- --------------- J Z 0 0 W LIJ CL Z Ili N 0 U_ 0 00 Z W U) D E 1 ARKAY 17996 MOUNT EACH UNIT 7'4" A.F.F. PIONEER MINI SPLIT SYSTEM MODEL WYS009AMFI 17RL -14-0��iT�U�;0--12.dVTPR-lf-SE-ER - - - - - - - - - - - - - - - - - - - - - - 7 — — — — — — — — — — — -=7= :1- — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — - — — -- — — — — — — 250 _350 SQ FT. CAPACITY 25 1 METER I THt FEM- — ------------------------- TD 25 200 A P T.C. ELEC N — 48" STORAGE — — 30 SHELVES 36" STORAGE — 18 TIT L WATER — E� SHELVES — 63" COM DE =_P FREEZER REFRIG K =1 L36- iEATER — 30" ICE 7 IKO 22 28 — MACHINE ri 20 19 29 18 E=- GF HAND DRYER 443 22 19 2 30" STORAGE U 16 X SHELVES 4a 14,22 UJ 9 1 19 r LU 1 18- 29� 0][ 23 C 17 18 0 17 C) 15 0"5 R3 18 19-4 0 14 12 10 21 0i X LU TAVL WALL 2:;L X LLI 17 F` 30" ICE MACHINE T 18 8 6 4 36" STORAJ SHELVES 48" STORAGE 36" R�FFRIG 63" COM D�P FREEZER \Irq 0- O_ :� 0=1C)_1 F 7 7717,17 7 ------------------------ A MV L L----------- --------- --------------------------- ---------------------------------- ---------------------------- --------------- J HOSE BIB 1 81' 4" 8'8" 8' 8" 36' 8" 8' 0" 36' 8" CE MACHINE TO CONNECT NDIRECT TO BUILDING DRAIN 3' 0" WITH AN AIR GAP TYP. co PLACE CONDUIT IN SLAB CD AT THIS LOCATION FOR 11- 8" ELECTRICAL 3" I'D C) 13'7" 1'4" — - — - — - — - — - — - — - — - — - — 3-COM—PAR-TME—NTSI-NKT—OCO-NNEC—TIN-DIREC—T TO BUILDING DRAIN WITH AN AIR GAP TYP. A 3"FD I PLUMBING FIXTURE LOCATION PLAN 1/411 = 1 foil M'M 14" CO — — — — — — — — — — — - - - - - - - - - - 3" I'D 3" I'D 3 COMPARTMENT SINK TO CONNECT INDIRECT TO BUILDING DRAIN WITH AN AIR GAP TYP. NFD �' 177�— — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — -------------- -------- 3" I'D COMP 37 COMPARTMENT SINK TO CONNECT INDIRECT T T 0 BUILDING DRAIN WITH AN AIR GAP TYP. 3" FD 3" I'D 3" Fj —j-FD L LLLk- 3' FD1 1 1/2" VTR 1 1/2" VTR I 11/2" VTR I 1/2"VTR 4" 4" 3' FID LAV 3 rV3 3" HW SK 3COMPSK 3" VTR 2" 1 z 12- jkq I Wc F D 3" ji 3 1 Y 1 3" SANITARY DRAIN LINE PLAN 1/491 = if off LAV �C WF 3" Z4' FD - 1 1/2" VTR 3' /3 1 1/2" VTR U IN 1 1/2" VTR 2" URINAL L- 2" LAV Wc 3" L-v ALL SANITARY PIPING TO BE SCHL 40 PVC ALL FLOOR DRAINS TO HAVE PRIMERS SANITARY RISER DIAGRAM NOT TO SCALE 1 1/2" VTR SK 1 1/2" LAV 1 1/2" VrR �W SK i 3 COMP 1 1/2" 4" 1 CONNECT INDIRECT TO FID DRAIN WITH AIR GAP 3" 1 3" 4- m FID 4" FD 4" �O S ICE h /I -- - - - - - - - - - - - - - - - 6" MAX. TOE CLEARANCE C) 17" MAX LAV DEPTH '-- 8" MIN KNEE CLEARANCE HANDICAP SINK DETAIL SINK 1. SINK SHALL BE MOUNTED WITH THE COUNTER OR RIM NO HIGHER THAN 34" FROM THE FINISH FLOOR. EACH SINK SHALL BE MINIMUM OF 6 1/2" DEEP. UNOBSTRUCTED SPACE OF AT LEAST 60" IN DIAMETER OR 52" BY 72" FINISH INSIDE DIMENSIONS ADJACENT TO THE LAVATORY AREA. SUCH CLEAR FLOOR SPACE SHALL ADJOIN OR OVERLAP AN ACCESSIBLE ROUTE AND SHALL EXTEND A MAXIMUM OF 19" UNDERNEATH THE LAVATORY OR SINK FRONT VIEW 3' 21/2" ,Ole MINIMUM CLEAR OPENING TOP VIEW =co FINISH FLOOR HI LOW A.D.A. WATER FOUNTAIN DETAIL NOT TO SCALE PLUMBING FIXTURE SCHEDULE FLOOR MOUNT AMERICAN STANDARD 2857.016.02 ADA TOILET WATER CLOSET WITH MANUAL FLUSH CHROME FITTINGS OR EQUAL AMERICAN STANDARD 0321.023.020 COLOR: WHITE WALL MOUNT SGL LEVER HANDLE 6114.110.002 LAVATORY WITH TEMP CONTROL FAUCET, P TRAP WRAP KIT OR EQUAL AMERICAN STANDARD WHITE MODEL 6590.001.020 URINAL MANUAL FLUSH VALVE MODEL 6045.101.002 OR EQUAL ELKAY MODEL WATER FOUNTAIN EZSTL8LC MOP SINK MUSTEE MODEL 12C POLY TUB WITH METAL LEGS AND FAUCET ELECTRIC PRO LINE 40 GALLON HAND WASH SINK REGENCY WALL MOUNT 17X1 5 WITH GOOSE NECK FAUCET ADVANCE TABCO FE-3 -1014 SINK 3 COMPARTMENT SINK REGENCY 8" OC 12" SWING OUT FAUCET OR EQUAL GRAB BARS 18 GA SATIN FINISH STAINLESS STEEL 1 1/4" MANUFACTURE BOBRICK SATIN FINISH 40 FL OZ MODEL BOB 2112 SOAP DISPENSER MANUFACTURE BOBRICK TOLIET TISSUE SATIN FINISH B 2888 DISPENSER MANUFACTURE BOBRICK HAND DRYER B 7125 AUTOMATIC HAND DRYER MANUFACTURE BOBRICK B 293-1830 FIXED POSITION MIRRORS TILT MIRROR MANUFACTURE BOBRICK EZ FLO 20182 MALE LOCK HOSE B LEVER HOSE BIB SOLID CORE REINFORCED COMPOSITE RESTROOM PARTITIONS SIERRA SERIES 1090 OVER HEAD BRACED FLOOR ANCHORED MANUFACTURE BOBRICK 54" MIN TOILET 18" MIN F 18" MIN PAPER 24" MIN 42" MIN HOLDER 7 7 LAV z C? 7 CLEAR FLOOR co SPACE HANDICAP TOILET DETAIL --------------- GRABBARS 60" MIN A GRAB BAR SHALL BE PROVIDE. LOCATED 33" INCHES FROM AND PARALLEL TO THE FINISHED FLOOR. MEASURED VERTICALLY TO THE TOP OF THE RAIL 1. SHALL HAVE AN OUTSIDE DIAMETER OF 1 1/2 INCHES 2. SHALL PROVIDE 1 1/2 INCHES OF CLEARANCE BETWEEN THE RAIL AND THE WALL. 3. SHALL BE SO DESIGNED AND SUPPORTED AS TO WITHSTAND A LOAD OF NOT LESS THAN 250 LBS APPLIED AT ANY POINT. DOWNWARD OR HORIZONTALLY. 4. SHALL BE CONTINUOUSLY GRASPABLE ALONG THE ENTIRE LENGTH. SPECIAL NOTE: GRAB BAR MEETING THE APPLICABLE ANSI STANDARDS ARE DEEMED TO BE IN COMPLIANCE WITH THE INTENT OF THE LAW WHETHER CENTER SUPPORTS EXIST OR NOT. 5. SHALL BE AT LEAST 42 INCHES LONG AND SHALL BE CENTERED AT THE LEADING EDGE OF THE WATER CLOSET. MAIN WATER LINE 1" BRANCH LINE TO FIXTURES 3/4" HOT WATERLINE FROM HEATER TO FIXTURES 3/4" 1. ALLWATER PIPING TO BE CPVC OR EQUAL 2. CIRCULATING PUMP REQUIRED TO BE 3/4" LINE TO ALL HOSE BIBS AT LOCATIONS SHOWN LOCATED BY PLUMBING CONTRACTOR ON FLOOR PLANS AND FIXTURE LOCATION PLAN WATER RISER DIAGRAM NOT TO SCALE WATER HEATER 11, sov I AETER No kCHINE GINEERING INC. :ZAL ENGINEERS �-/[CHARD L. KIDDEY P.E. FILORIDA LICENSE NUMBER 37296 1 HERBY CERTIFY THAT THESE PLANS AND SPECIFICATIONS WERE PREPARED BY ME OR UNDER MY DIRECT SUPERVISION ARE IN COMPLIANCE WITH CHAPTER 16, SECTION 1609 OF THE FLORIDA BUILDING CODE 2017 6TH EDITION AND ASCE 7-10 FOR 139 MPH WIND ZONE RISK CATEGORY 11 r- (P c6l w Q) cq 2 N L x to s- d) IL o -z Z Q) Q) u- -v w Mu w c Z Q) -1 Q) uj Q) cz Q) 0 M, W OIL _I LU Q) Q) co c-A), 0 T- T- Z CIS cl� 0 0 0 C'6 c) 0 w x I I p- co 00 L6 L6 ce) 00 OIS z 0 6i z 0 3 (D z U) —j Z 0 U) W r (-) z 0 u- C) 00 —i w u— z w cf) :D p I ARKAY 17996