SCOPE:
INTERIOR RENOVATION OF NEW BATHROOM, KITCHEN AND NEW BEAMS/COLUMNS
Hynes Discount V i i i
Apollo Mediation
MobileHome.
Moody's Hardwar'e
1,7!vT dve a r v- a t o e
El
V,
j
11-annoz food rnarket',
Sa i g o n C
1 k I
c cj s, Z -3
Metro by T-Mobile
CeV', Phone
SITE
In Due Season
-IN Bitth Cf_'mter Farnily-,
5006 8th St.
03
Zeprhyrhills, FL,33542
F? J F r d C;'.
Angels Prest::hool
Whiffield Funeral
DHome & Crmtri
Sou u I I -i Av e South Ave
C3
Big Me c
0 199 Cleariers
PROPERTY LOCATION
INDEX:
ITEM
DRAWING #
DESCRIPTION
1
T-1
-TITLE, PROPERTY LOCATION, AND NOTES
2
A-1
-LAYOUTS
3
S-1
-STRUCTURAL DESIG AND DETAILS
4
N-1
-NOTES
5
----
-----
6
----
-----
7
----
-----
8
----
-----
9
----
-----
10
11
----
-----
ABBREVIATIONS;
ITEM
DESCRIPT10N
ABBREMA11ON
ITEM
DESCRIPTION
ABBREVIATION
1.
DIAMETER
DIAM.
18.
NEW
N
2.
ELEVA11ON
EL
19.
MAXIMUM HEIGHT
M.H.
3.
EXISTING GROUND
20.
WATER PROOF
WP
ELEVA11ON
E. G. EL.
21.
EACH WAY
E.W.
4.
FLOOR ELEVATION
F. EL.
22.
HEXAGON
HEX.
5.
ROOF ELEVATION
R. EL.
23.
PRESSURE TREATED
P.T.
6.
INVERT ELEVATION
1. EL.
24.
ALUMINUM
ALUM.
7.
TOP ELEVATION
T. EL.
25.
TYPICAL
TYP.
8.
THICKNESS
TH.
9.
TOP OF WALL
T.W.
10.
FINISHED FLOOR
ELEVA11ON
F.F.
11.
NOTIN CONTRACT
N.I.C.
12.
CENTER TO CENTER
C.C.
13.
NOT TO SCALE
N.T.S.
14.
EXISTING
EX.
15.
TOP & BOTTOM
T&B
16.
MAIN DISTRIBUTION
PANEL
MDP
17.
GRAPHIC SCALE
G.S.
NOTE:
THE STRUCTURAL INTEGRITY OF THE BUILDING SHOWN ON THESE PLANS IS DEPENDENT
UPON COMPLETION ACCORDING TO PLANS & SPECIFICATIONS. STRUCTURAL MEMBERS ARE
NOT SELF-SUPPORTING DURING CONSTRUCTION & REQUIRE TEMPORARY BRACING UNTIL
PERMANENTLY AFFIXED TO STRUCTURE AS DIRECTED. THE ENGINEERS ASSUME NO
LIABILITY FOR THE STRUCTURE DURING CONSTRUCT10N UNLESS THE CONSTRUCTION
METHOD & BRACING ARE INCLUDED IN THE PLANS & SPECIFICATION, OR ARE
SUPERVISED BY THE ENGINEER DURING CONSTRUCTION.
THIS DRAWING IS SEALED ONLY FOR THE STRUCTURAL PORTION OF THE DETAILS &
SPECIFICATIONS. NON-STRUCTURAL INFORMATION, SUCH AS ELECTRICAL, MECHANICAL,
ARCHITECTURAL & PROPERTY SURVEY, IF SHOWN, ARE NOT COVERED UNDER THIS SEAL
THIS DRAWING IS VAUD FOR 12 MONTHS AFTER THE DATE OF THE SIGNATURE.
GENERAL NOTES:
1. ALL STRUCTURAL LUMBER & EXTERIOR FRAMING TO BE #2 SOUTHERN YELLOW PINE
OR EQUIVALENT EXCEPT AS SHOWN ON DRAWINGS.
2. ANY WOOD BELOW THE REQUIRED BASE FLOOD ELEVATION SHALL BE 0.40 CCA
TREATED (FLOOD RESISTANT)
3. FOU OW ALL REQUIREMENTS OF FLORIDA BUILDING CODE, 7th EDITION, 2020,
(CURRENT EDITION) FOR ALL WOOD FRAMING INCLUDING BUT NOT LIMITED TO
CONNECTIONS, BRACING BRIDGING & NAILING.
4. BUILDING CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS, DIMENSIONS, ROUGH
OPENINGS, AND DETAILS & MATCH EXISTING CONDITIONS AS CLOSELY AS POSSIBLE.
NOTIFY ENGINEER OF ANY DISCREPANCIES FOUND PRIOR TO STARTING OR DURING
CONSTRUCTION
AL!
Sri
C_ VV L-)
"EIPH Y
P L AINI E /X, A Nil I NE Pl,
2810 NORTH 10TH STREET
TAMPA, FL 33605
Office: (813) 616-3301
Mobile (970) 703-3284
LeoOBerylProjectEngineeringxorn
F&EVINONS
No. DESCRIPTION DATE
01--i
Nt
0
L0
<
LLJ
LLJ
>
3:
11�
0
0
z
a_
U)
LLJ
ry
C/)
0
00
ry
C)
0
(.0
ry
ck�
<
CD
LLJ
Q:�
Q
I—
m
Ln
CL
Ld
r*`�
BUILD IN ACCORDANCE WITH:
FLORIDA BUILDING CODE,
7TH EDITION, 2020
(CURRENT EDITION)
DESCRIPTION
TITLE,
PROPERTY LOCATION, AND NOTES
'00�
C16-f-
CIL-
Richard Leon Cannyn, PMP, P.E.
P.E. # 65994
SCALE DRAVANG No.
AS -SHOWN T- 1
PROJECT No. DRAFTER: BRMDESIGNER: LG
15558 REMEWER: LV
TO BE CHECKED BY -LC
DATE SHEET No.
8/18/2021 1 OF 4
0
13 9
f I , 50-3"
23-11 1
17'-7j"
L' 29 11"2' 11"2' 11
,OX-31-1 . 1 1 1 1 %.# —2j
40'-6j"
3 9 —2j"
40 A"
22 P-11"
-2'-14 "
29-6"
30-84" .4 X-30 _ 1 100' 4'-3"--7f-3-3"-,
EXISTING LAYOUT
1/8 "=1 $—on
33 0 —94 "
SCOPE NOTES: 2
F- -T-
NEW LAUNDRY
NEW MASTER BATH
NEW OPENING BETWEEN NEW LAUNDRY ROOM AND MASTER BEDROOM
NEW LVL BEAM IN KITCHEN AND DINING ROOM
CLOSE EXISTING DOOR ACCESS
PROPOSED LAYOUT
1/8 ft=is—ost
BERYL
ii z 4 � 0,11 z IV- I
2810 NORTH 10TH STREET
I TAMPA, FL 33605 1
Office: (813) 616-3301
Mobile (970) 703-3284
Leo0BerylProjectEngineering.com
W"
0
In
LLJ
r"-)
<
LLJ
I'l
>
3:
ry
0
0
1--
z
n
(J�
LL]
0:�
7,
=
V)
0
1--
00
—1
—j
ry
0
Q0
ry
<
0
Li
ry
0
F--
m
Ln
n
7r
III
N
BUILD IN ACCORDANCE WITH:
FLORIDA BUILDING CODE,
7TH EDITION, 2020
(CURRENT EDITION)
DESCRIPTION
LAYOUTS
EN
No. 65994 0 gas
go a
STATE 0 F :4rft
44/
,020$
OR\ 00
ONAL
#*'1881112sto
Richard Leon Cannyn, PIVIP, P.E.
P.E. # 65994
SCALE DRAVANG No.
AS —SHOWN A-1
PROJECT No. DRAFTER: BRM DESMER:LG
15558 REMEWER: LV
TO BE CHECKED BY- LC
DATE SHUT No.
8/18/2021 2 OF 4
Ll 11 Low I?
TOP PLATE ATTACHED TO 2x4
WALL STUD WITH SIMPSON SP1 (TYP.)
2x4 STUDS (TYP.) _
2x4 STUDS 016" O.C.-
BOTTOM PLATE ATTACHED TO 2x4
WALL STUD WITH SIMPSON SP1 (TYP.)
3/8"0 x 4" 01 2n TAPCON SCREWS _
11F
=a -
TYPICAL NON —LOAD BEARING WALL DETAIL (CONC. BASE
1/4 "=1 $—on
R-19 INSULATION
1/2" DRYWALL
TYPICAL INTERIOR WALL SEC11ON
5/8 "=1 t—O"
TOP PLATE ATTACHED TO 2x4
WALL STUD WITH SIMPSON SP1 (TYP.',
(2)2x8 HEADER FIXED WITH (2) SIMPSON MSTA2
(2)2x4 STUDS ATTACHE
TOGETHER TO SUPPORT HEADE
2x4 BLOCKIN
2x4 STUDS 016" O.0
BOTTOM PLATE ATTACHED TO 2xA
WALL STUD NTH SIMPSON SP1 (TYP.'
1/4"0 x 4" 012" SIMPSON SDS (TYP.'
TYPICAL NON —LOAD BEARING WALL DETAIL W/ DOOR (WOOD B
1/4 "=1 $—on
BERYL
2810 NORTH 10TH STREET
I TAMPA, FL 33605 1
Office: (813) 616-3301
Mobile (970) 703-3284
LeoOBerylProjectEngineeringxom
5j
Nt
L0
7FEXISTENT DRYWALL DRYWALL 1 11 11 _j LLJ 1"�")
LINTEL LLj LLJ N')
L#4012
PANEL INSULATION L45 3�: af
PANEL INSULATION
v
w
f'-. 8" LINTEL TO EXTEND _j
SEE NOTE "A" SEE NOTE "A" 8" LINTE N 0
12] PAST OPENING 8" ON
L
2"x4" TOP 2"x4" FIXED 8"x8"xl 6" CMU "A" 48 EACH SIDE 7p n V)
PLA TO CMU WITH _"'H 1 11 0%
Lij
I 4"x:rOl 6" BLOCK WALL; 100% A. GLUE THICK RIGID FOAM PANELS 9 �7 V)
FILLED CELLS JINNER WALLI DIRECTLY TO THE INSIDE FACE OF THE CMU. I
TAPCON HOOK (TYP.)
BOLTS (TYP.) USE FLASHING TAPE TO SEAL ALL JOINTS. 0 00 _j
THEN FASTEN 1"xl" WOOD FURRING STRIPS
r TO THE CMU AT 16" CENTERS & FASTEN
2"x4" STUD SHEET ROCK
(TYP.) LLJ 0
I EXIS�TING -- 8"X8"X1 6" m Ln
2"x4" _TCMU 5� TYPICAL INTERIOR CMU WALL SECTION
WALL "=1 $—on CMU BLOCKS LLJ
BOTTOM 1/4
�LATET'
#5, 100% N
FILLED
CMU WALL
DETAIL WITH DOOR FILL IN
1/4 "=1 $—on
SIMPSON MSTA1
ON BOTH SIDE
NEW 4x4 DSS COLUMN
CUT EXISTING BOTTOM PLATE
TO CONNECT NEW 44 COLUMN
DIRECTLY TO SLAE
EXISTING CONCRETE '.
t'F�'\CMU DOOR DETAIL
� U_' N. T. S.
'6'OUT 2" NOTCH IN
qEW` 44 COLUMN
TO SEAT BEAM
EXISTING CMU WALL
NEW 4x4 DSS COLUMN
BUILD IN ACCORDANCE WITH:
FLORIDA BUILDING CODE,
7TH EDITION, 2020
(CURRENT EDITION)
DESCRIPTION
STRUCTURAL DESIGN AND DETAILS
L EpAj
east,
C\c E N
.00,
� to**
to
to
No. 65994 1
so STATE OF
os 0
*�Z 0 R
#10NAL
188811111112900
Richard Leon Cannyn, PMP, P.E.
P.E. # 65994
SCALE DRAVANG No.
AS —SHOWN S-1
PROJECT No. DRAFTER: BRM DESIGNER: LG
15558 REVIEWER: LV
TO BE CHECI(ED BY- LC
DATE SHUT No.
8/18/2021 1 3 OF 4
I i L 1 11 1�
GENERAL NOTES:
1. BEFORE STARTING THE WORK ON THE PROJECT, THE CONTRACTOR WILL HAVE TO VERIFY THE EXISTING
CONDITIONS & DIMENSIONS.
2. ANY DISCREPANCIES SHALL BE REPORTED TO THE ENGINEER.
3. THE CONTRACTOR NEEDS TO COMPLY NTH ALL CONSTRUCTION CODES AND REGULATIONS ESTABLISHED
BY FLORIDA STATE.
4. THE CONTRACTOR NEEDS TO APPLY A GROUND TERMITE TREATMENT ACCORDING TO FLORIDA BUILDING
CODE.
5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR REPAIRING TO ORIGINAL CONDITIONS, ANY DAMAGES TO
BUILDING SURFACESt EQUIPMENT, ETC. CAUSED DURING THE CONSTRUCTION.
6. THE CONTRACTOR SHALL KEEP ALL AREAS WHERE WORK IS BEING PERFORMED FREE FROM DEBRIS AT
ALL TIMES. AREA SHALL BE LEFT BROOM CLEAN AT THE END OF EACH WORKING DAY.
7. ALL LUMBER (INTERIOR) SHALL BE COVERED WITH GYPSUM BOARD, r THICKNESS.
8. THE CONTRACTOR NEEDS TO COORDINATE WITH THE ELECTRICIAN FOR THE ELECTRICAL WORKS.
9. THE CONTRACTOR NEEDS TO COORDINATE WITH THE PLUMBER FOR THE PLUMBING WORKS.
10.THE CONTRACTOR NEEDS TO COORDINATE WITH HIS CONSULTANTS FOR THE A/C SYSTEM, ENERGY
CALCULATION, ETC.
11. THE CONTRACTOR NEEDS TO COORDINATE WITH THE OWNER THE FINISHED FLOOR PRODUCT OF HOUSE.
12. THE CONTRACTOR NEEDS TO COORDINATE WITH THE OWNER FOR THE CABINET DIMENSIONS, LAYOUT, OR
OTHER INFORMATION. THE CONTRACTOR HAS TO RELOCATE THE HOT & COLD WATER PIPE, THE
DISCHARGE PIPES AND THE ELECTRICAL RECEPTACLES ACCORDING TO THE OWNERS LAYOUT. THE
CONTRACTOR WILL HAVE TO VERIFY THE EQUIPMENTS (REFRIGERATOR, SINK, DRYER/WASHER) THAT THE
OWNER WILL PROVIDE TO DETERMINE THE EXACT LOCATION OF WATER SUPPLY, DISCHARGE PIPE OR
ENERGY SUPPLY.
13. THE CONTRACTOR NEEDS TO INSTALL IN THE WALL A FIBERGLASS INSULATION R-19
14. THE ROOF CEILING WILL BE 1/2"GYPSUM BOARD AND INSULATED WITH FIBERGLASS INSULATION R-30
(FLAT ROOF).
15. ANY LUMBER IN CONTACT WITH CONCRETE SHALL BE PRESSURE TREATED OR SHALL NEED A SILL
GASKET TO AVOID MOISTURE INTRUSION.
STRENGTH OF MATERIALS
1.
CONCRETE FOOTINGS, SLAB & BEAM
f c
3,000 psi
2.
REINFORCING STEEL
fy
60,000 psi
3.
REINFORCED MASONRY
fm
1,500 psi
4.
MASONRY GROUT
fc
3,000 psi
5.
SOIL BEARING (ASSUMED, TO BE VERIFIED)
2,000
psf
6.
BOLTS FOR STEEL & WOOD CONNEC11ONS
A307
7.
FRAMING LUMBER
#2 SYP
8. SHEATHING DIAPHRAGM (ROOF)
8.1. UNBLOCKED DIAPHRAGM
9. SHEATHING DIAPHRAGM (WALLS)
9.1. UNBLOCKED DIAPHRAGM
10. DECK DIAPHRAGM (FLOORS)
10.1. UNBLOCKED DIAPHRAGM
B APA RATED SHEATHING
ALLOWABLE SHEAR=285 POUNDS PER FOOT 10d
DEFORMED NAILS 06" O.C. AT ALL ENDS, EDGES,
CUTS & TERMINATIONS & 0 12" O.C. AT INTERIOR
SUPPORTS.
!j APA RATED SHEATHING
ALLOWABLE SHEAR=310 POUNDS PER FOOT 10d
DEFORMED NAILS 06" O.C. AT ALL ENDS, EDGES,
CUTS & TERMINATIONS & 0 12" O.C. AT INTERIOR
SUPPORTS.
!a APA RATED SHEATHING
ALLOWABLE SHEAR=825 POUNDS PER FOOT
CONSTRUCT10N ADHESIVE & (2) ROWS OF 10d
DEFORMED NAILS 06" O.C. AT ALL ENDS, EDGES,
CUTS & TERMINA11ONS & 0 12" O.C. AT INTERIOR
SUPPORTS.
COMPONENTS & CLADDING WIND PRESSURE CHART
TERMITE NOTES.-
1. A PERMANENT SIGN WHICH IDEN11FIES THE TERMITE TREATMENT PROVIDER AND NEED FOR
RE-INSPEC11ON & TREATMENT CONTRACT RENEWAL SHALL BE PROVIDED. THE SIGN SHALL BE
POSTED NEAR THE WATER HEATER OR ELECTRIC PANEL.
2. CONDENSATE AND ROOF DOWN SPOUTS SHALL DISCHARGE V-0" AWAY FROM BUILDING SIDE WALLS.
3. IRRIGATION/SPRINKLER SYSTEM INCLUDING ALL RISERS AND SPRAY HEADS SHALL NOT BE INSTALLED
WITHIN V-0" OF THE BUILDING SIDE WALLS.
4. TO PROVIDE FOR INSPECTION FOR TERMITE INFESTATION THE DISTANCE BETWEEN WALL COVERING &
FINAL EARTH GRADE SHALL NOT BE LESS THAN 6". EXCEPTION: PAINT OR DECORA11VE CONTEN11OUS
FINISH LESS THAN 5/8" THICK ADHERED DIRECTLY TO THE FOUNDATION WALL.
5. INITIAL TREATMENT SHALL BE DONE AFTER ALL EXCAVA11ON AND BACKFILL IS COMPLETE. IN
ACCORDANCE WITH FLORIDA BUILDING CODE 7th ED111ON 2020 SECTION 1816.1.1
6. SOIL DISTRIBUTED AFTER THE INITIAL TREATMENT SHALL BE RE -TREATED INCLUDING SPACES BOXED
& FORMED. IN ACCORDANCE WITH FLORIDA BUILDING CODE 7th EDITION 2020 SECTION 1816.1.2
7. BOXED AREAS IN CONCRETE FLOORS FOR SUBSEQUENT INSTALLATIONS OF TRAPS, ETC., SHALL BE
MADE WITH PERMANENT METAL OR PLASTIC FORMS. PERMANENT FORMS MUST BE THE SIZE AND
DEPTH THAT WILL ELIMINATE THE DISTURBANCE OF SOIL AFTER THE IN111AL TREATMENT. IN
ACCORDANCE WITH FLORIDA BUILDING CODE 7th EDITION 2020 SECTION 2304.11
8. MINIMUM 6 MIL RETARDER MUST BE INSTALLED TO PROTECT AGAINST RAINFALL DILUTION. IF
RAINFALL OCCURS BEFORE VAPOR RETARDER PLACEMENT, RETREATMENT IS REQUIRED. IN
ACCORDANCE WITH FLORIDA BUILDING CODE 7th EDIT10N 2020 SECTION 2304.11.
9. CONCRETE OVER POUR AND MORTAR ALONG THE FOUNDA11ON PERIMETER MUST BE REMOVED
BEFORE EXTERIOR SOIL TREATMENT. IN ACCORDANCE WITH FLORIDA BUILDING CODE 7th ED11ION
2020 SEC11ON 2304.11.
10. SOIL TREATMENT MUST BE APPLIED UNDER ALL EXTERIOR CONCRETE OR GRADE WITHIN V-0" OF
THE STRUCTURE SIDEWALLS. IN ACCORDANCE WITH FLORIDA BUILDING CODE 7th ED111ON 2020
SECTION 2304.11.
11. AN EXTERIOR VER11CAL CHEMICAL BARRIER MUST BE INSTALLED AFTER CONSTRUC11ON IS COMPLETE
INCLUDING LANDSCAPING & IRRIGATION ANY SOIL DISTRIBUTED AFTER THE VERTICAL BARRIER IS
APPLIED, SHALL BE RETREATED. IN ACCORDANCE WITH FLORIDA BUILDING CODE 7th EDITION 2020
SECT1 ON 2304.11.
12. ALL BUILDING ARE REQUIRED TO HAVE PRE -CONSTRUCTION TREATMENT. IN ACCORDANCE WITH
FLORIDA BUILDING CODE 7th ED11ION 2020 SEC11ON 2304.11.
13. A CER11FICATE OF COMPLIANCE MUST BE ISSUED TO THE BUILDING DEPARTMENT BY A LICENSED
PEST CONTROL COMPANY BEFORE A CERTIFICATE OF OCCUPANCY WILL BE ISSUED. THE CERTIFICATE
OF COMPLIANCE SHALL STATE: "THE BUILDING HAS RECEIVED A COMPLETE TREATMENT FOR THE
PREVENTION OF SUBTERRANEAN TERMITES THE TREATMENT IS IN ACCORDANCE WITH THE RULES &
LAWS OF THE FLORIDA DEPARTMENT OF AGRICULTURE & CONSUMER SERVICES." IN ACCORDANCE
WITH FLORIDA BUILDING CODE 7th EDITION 2020 SECTION 2304.11.
14. AFTER ALL WORK IS COMPLETED, LOOSE WOOD AND FILL MUST BE REMOVED FROM BELOW AND
WITHIN V-0" OF THE BUILDING. THIS INCLUDES ALL GRADE STAKES, TUB TRAP BOXES, FORMS,
SHORING OR OTHER CELLULOSE CONTAINING MATERIAL.
15. NO WOOD, VEGETATION, STUMPS, CARDBOARD, TRASH, ETC., SHALL BE BURIED WITHIN 15'-0" OF
ANY BUILDING OR PROPOSED BUILDING.
COMPONENTS & CLADDING ULTIMATE PRESSURE SCHEDULE
WALLS, DOORS & WINDOWS ENCLOSE BUILDING
GCp, = +/- 0.18
INDICATES OUTWARD; (+) INDICATES INWARD
COMPONENTS & CLADDING ULTIMATE PRESSURE SCHEDULE
ROOFS & WINDOWS ENCLOSE BUILDING
GCpj = +/- 0.18
INDICATES OUTWARD; (+) INDICATES INWARD
EFFEC11VE AREA
COMPONENT
4' OF EAVE OR
TRANSITION
WITHIN 4!
CORNER
TRANSITION
NOT WITHIN 4'
CORNER
EFFECTIVE AREA OF
COMPONENT
WITHIN 4'
CORNER
NOT WITHIN 4' OF
CORNER BUT WITHIN
NOT WITHIN 4' OF
CORNER, EAVE OR
0 SF<AREA<20 SF
+36.2 -48.5
+36.2 -39.3
0 SF<AREA<20 SF
+20.9 -57.7
+20.9 -57.7
+20.9 -33.2
2U_7ZQMW<7U_7_
+34.7 --45.7
+34.7 -37Y.-
20 SF<AREAZU_9F_
+19.0
+19.0
+19.0 -32.2
30 SF<AREA<-40 SF
+33.8 -43.3
+33.8 -36.8
30 SF<AREA<40 SF
+17' .8 -50.3
+17.8 -50.3
-31.6
40 SF<AREA<50 SF
+32.8 -42.1
+32.8 -35.9
40 SF<AREA<50 SF
+17.2 -48.5
+17.2 -48.5
_+17.8
+17.2
-31.3
50 SF<AREA<75 SF
+32.5 -40.8
+32.5 -35.6
50 SF<AREA<75 SF
+16.6 -47.0
+16.6 -47.0
+16.6
-31.0
75 SF<ARF-A<100 SF
+31.6 -N.7U-
+31.6 -34.7
75 SF<AREA<100 SF
+15.4 -
+15.4 -
+15.4 -30.4
.
100 SF<AREA<125 SF
+30.7 -37.8
+30.7 -33.8
100 SF<AREA<125 SF
+14.7 -42.4
+14.7 -42.4
+14.7 -30.1
125 SF<AREA<150 SF
+30.4 -36.5
+30.4 -33.5
125 SF<AREA<150 SF
+14.7 -42.4
+14.7 -42.4
+14.7 -30.1
AREA>150 SF
+29.8 -35.6
+29.8 -32.8
AREA>150 SF
+14.7 -42.4
+14.7 -42.4
+14.7 -30.1
NOTE: ALL BUILDING ELEMENTS EXPOSED TO WIND SHALL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS TO RESIST THE WIND
PRESSURES INDICATED & TO MEET OTHER CODE REQUIREMENTS FOR AIR & WATER INTRUSION. WIND LOADS ABOVE ARE ULTIMATE LOADS.
USE UL11MATE WIND PRESSURE W/ ASCE-7/16 LOAD COMBINATIONS. MULTIPLY LOADS BY 0.6 TO OBTAIN NOMINAL LOADS.
PRODUCT APPROVAL LIST HARDWARE
11EM
PRODUCT
mnnFl
SUB
CATEGM
MANUFACTURER
FLORIDA
APPROVAL
EXPIRATION
DATE
-
1
HUCQ412
FACE -MOUNT HANGER
SIMPSON STRONG TIE
I
FLF10531.1-R5
12-23-23
2
MSTA12/MSTA24
STRAIGHT STRAP
SIMPSON STRONG TIE
FLfI3872.9-R4
12-31-21
3
ABU44Z/ABU66Z
ADJUSTABLE POST BASE
I SIMPSON STRONG TIE
FL#10860.2-R5
12-17-23
STRUCTURAL NOTES:
1. BEFORE STARTING CONSTRUCTION, THE CONTRACTOR NEEDS TO VERIFY THE
EXIS11NG COND111ON & DIMENSIONS.
2. ALL VERTICAL, HORIZONTACOR DIAGONAL MEMBERS SHALL BE CONNECTED
USING STRAP CONNECTORS.
3. ALL CONCRETE WORK SHOULD COMPLY NTH ACI 301, ACI 318, ACI 315
LATEST EDITION
4. THE REINFORCING STEEL SHALL BE GRADE 60, ASTM A-615
5. THE CONCRETE MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI & W/C
0.55 FOR 28 DAYS FOR REINFORCE CONCRETE WALLS
6. CONCRETE MASONRY BLOCKS SHALL COMPLY WITH THE REQUIREMENTS OF
ASTM C90. MORTAR FOR MASONRY CONSTRUCTION SHALL CONFORM TO THE
REQUIREMENTS OF ASTM C270. FILL ALL MASONRY CELLS WITH CONCRETE.
7. CONSTRUCTION JOINTS SHALL BE SPACED NO GREATER THAN 20' O.C.
8. ALL JOINT REINFORCEMENT, TIES & OTHER ACCESSORIES SHALL BE
RESISTANT TO CORROSION.
9. THE CONTRACTOR SHALL USE A HOT -DIPPED ZINC -COATED GALVANIZED
STEEL BOLTS FOR PRESSURE TREATED WOOD.
10. GLUE J" THICK RIGID FOAM PANELS DIRECTLY TO THE INSIDE FACE OF
THE CMU. USE FLASHING TAPE TO SEAL ALL JOINTS. THEN FASTEN
1"xl" WOOD FURRING STRIPS TO THE CMU AT 16" CENTERS &
FASTEN SHEET ROCK
11. THE CONTRACTOR NEEDS TO INSTALL A "365 BENT GRIPSTAY CHANNEL SLOT
ANCHOR TIES" (OR EQUAL), GA 16 WITH A "362 GRIPSTAY CHANNEL SLOr
(OR EQUAL) ON BOTH SIDES OF THE OPENINGS. THE WALL TIES WILL BE
INSTALL ON EACH LINE OF THE CMU BLOCKS.
12. THE BATHROOM SIDE WALL NEEDS BE COVERED WITH HARDIEBACKER 500
CEMENT BOARD WITH INSULATION. ALWAYS LAY THE HARDIEBACKER BOARD
IN A STAGGERED PATTERN. FILL ALL JOINTS WITH THIN SET CEMENT, THEN IN
BED 2" WIDE HIGH STRENGTH ALKALI RESISTANT GLASS FIBER TAPE.
13. 8"x8" LINTEL BY CAST-CRETE CORP, ADD A #5 REBAR (HORIZONTAL) &
#4012- (VERTICAL), FILL WITH CONCRETE & VIBRATE. FILL & VIBRATE ALL
CELLS ABOVE LINTEL 'NTH CONCRETE. (EQUAL OR SIMILAR)
14. THE CONTRACTOR SHALL PLACE CONCRETE ON THE BATHROOM &
DINING ROOM FLOOR UNTIL THEY REACH THE SAME LEVEL OF THE
HOUSE. THE CONTRACTOR SHALL COORDINATE WITH THE OWNER
THE FINISHED FLOOR PRODUCT/HARDWARE BEFORE PLACING THE
CONCRETE TOPPING IN THE LIVING ROOM AREA. THE CONTRACTOR
NEEDS TO USE "SIKALATEX R" AS A BOUNDING AGENT BEFORE
PLACING CONCRETE TOPPING.
15. THE CONTRACTOR SHALL DRILL A J"O HOLE (5") AND FILL WITH
EPDXY TYPE HILTY.
DESIGN CRITERIA
CODE
APPLIED = FLORIDA BUILDING CODE 7th EDITION (2020)
1.
LI VE LOAD
ROOF
20 PSF
FLOOR
40 PSF
2.
DEAD LOAD
ROOF
15 PSF
3.
WIND LOADS
140 MPH (ULTIMATE)
RISK CATEGORY
11
EXPOSURECATEGORY
wB"
INTERNAL PRESSURE
COEFFICIENTS; GC
*±0.18, ENCLOSED
STRUCTURE
*0.55, PARTIALLY
ENCLOSED STRUCTURE
*0.0 OPEN STRUCTURE
BASIC WIND PRESSURE
q=50.1 PSF
4.
SOIL BEARING
(ASSUMED TO BE VERIFIED)
Sb=2000 PSF
5.
CLASSIFICATION OF WORK
ALTERA11ON LEVEL 2
6.
TYPE OF CONSTRUCTION:
TYPE V-B
APPLICABLE CODES
FLORIDA BUILDING CODE 7TH EDITION (2020)
2020
FLORIDA BUILDING CODE, PLUMBING
2020
FLORIDA BUILDING CODE, MECHANICAL
2020
FLORIDA BUILDING CODE FOR
BUILDING CONSTRUCTION
2020
FLORIDA BUILDING CODE EXISTING
BUILDING
2020
FLORIDA ENERGY EFFICIENCY
CODE FOR BUILDING
CONSTRUC11ON
2017
NATIONAL ELECTRICAL CODE
0
oil MR$
Eli i
1Y ii L, # =� 0, �: L A
2810 NORTH 10TH STREET
I TAMPA, FL 33605 1
Office: (813) 616-3301
Mobile (970) 703-3284
Leo@Ber�ProjectEngineering.com
IFE'VKNONS
No. DESCRIPTION DATE
Ak I - - - -
N
0
LC)
Lj
n
<
LLJ
LLJ
>
3:
0:�
0
0
z
n
Ld
ry
z
0
00
_j
ry
0
(.0
ry
<
0)'__
LLJ
ry
0
m
In
N
BUILD IN ACCORDANCE NTH:
FLORIDA BUILDING CODE,
7TH EDITION, 2020
(CURRENT EDITION)
DESCRIPTION
NOTES
L EP/V
kC E N
%
No. 65994
STATE OF
10
0
pe $ 44
OXN (4
�Z
to
0 R
0 NA L
8888111112111,01
Richard Leon Cannyn, PMP, P.E.
P.E. # 65994
SCALE 0.
AS -SHOWN N-1
PROJECT No. DRAFTER: BRM DESIGNER: LG
15558 REVIEWER: LV
To BE CHECKED BY- LC
DATE SHUT No.
8/18/2021 1 4 OF 4