Loading...
HomeMy WebLinkAbout5039 1st St.k%_ I TOILET -ROOM BUILDING, 5039 1st St, Zephyrhills, FL 33 Consider= ItmDone General Contracting Keith Owens 218 East Bears Avenue, Tampa, FL 33613 813.955.0367 M A- Md M h- ............... .... . .. . .. .. 61& 1# # ................. . . OWN A- . . . . . . . . . . LOCATION MAP 17' NORTHN SCALE:NTS ISSUED FOR REVIEW: 04.26.19 ISSUED FOR REVIEW: 06.24.19 ISSUED FOR REVIEW: 07.16.19 ISSUED FOR PERMIT: 07.29.19 1 Iti El El El 0 El El El 1­71 El EJ El El El El El EJ El El El 1771 El El El El M" -If@ 130 S MASSACHUSSETTS AVE. SUITE 212, LAKELAND, FL 33801 863.450.4514 863.255.7033 victor@vprebor.com AA26003300 A95639 ID5865 KO Consulting Keith Owens, PE — 58497 218 East Bears Avenue, Tampa, FL 33613 813.955.0367 Drawing Index Cover Sheet - Site Plan S-100 Structural & Life Safety Plan G-100 General Notes A-100 Architectural Site Plan A-1 01 Floorplan &Elevations A-201 Exterior Elevations & Detail E-101 Electrical Plan P-101 Plumbing Plan REVIEW DATE 4r11121 CITY OF y -S = I S �AMINER FIRE AND IFEZ�y ALL WORK SHALL COMpLy WITH ES AND ST NFFA COD ANDARDS j, VC ;SC' r3 ALL VORK SHALL (;OM, PLY VV,T, CODES 'LORD UILDING PRr NATIONA )A 8 IC CODE, L ELECTR CODE, AND THE CITY OF ZEPHYRHILLS ORDINANCES A'- � , Victor M. Prebor AIA NCARB ID LEED AP Floddo A95639 ID5865 i�� 20'-0" I - X-M-Al M�Tki�nM�Tki� I 8" CMU BEMING W&L NORTH FOUNDATION PLAN 1/4 to = 1 $-of$ 4/ 0 2/ 4/ FOUNDATION NOTES 1. INSTALL CLEAN SAND FILL IN MAXIMUM 12' COMPACTED LIFTS. 2. STEM WALLS TO BE 8' CMU - GROUT SOLID - SEE PLAN FOR DOWEL LOCATIONS. 3. SAW CUT SLAB 1/4'Xl' WHERE SHOWN ON PLAN - ALL SLABS TO BE SEALED. 4. 4' FIBER REINFORCED CONCRETE SLAB NATURAL COLOR - CURE AND SEAL FINISH CLEANOUT OPENINGS SHALL BE PROVIDED FOR CELLS CONTAINING SPLICED REINFORCEMENT WHEN THE GROUT POUR EXCEEDS 5 FEET IN HEIGHT. CLEANOUT OPENINGS SHALL HAVE A MIN. AREA OF 12 SO. INCHES & A MINIMUM OPENING DIMENSION OF 3' FOOTING DOWELS SHALL BE PROVIDED AT ALL CORNERS AND VERTICAL REINFORCEMENTS MIN. 10' HOOK FOOTING MUST BE 12' BELOW STARTING GRADE OR COMPACTION TEST IS REO. 5. NOTICE OF TERMITE PROTECTION SHALL BE PREMANENT SIGN WHICH IDENTIFIES PROVIDER & NEED FOR REINSPECTION & TREATMENT CONTRACT RENEWAL SIGN SHALL BE POSTED NEAR THE ELECTRIC PANEL THIS PROPERTY WILL RECIEVE EITHER PRE-TREATMENT OR WOOD BORON TREATMENT W/ BORA-CARE AS ALLOWED BY THE F.B.C. 1816.1.8 & CHAPTER 482 OF THE FL STATUES. J L C14 6i C) z U) Ld of L LIFE SAFETY PLAN 1 1/4 of 1 $-off 4f 0 21 4' PROJECT DATA: PROJECT NAME: THE GREAT CATCH HARBOUR VILLAGE SHOPPING CENTER CONSIDER -IT -DONE CONTRACTING PROJECT LOCATION: 5039 1st St, Zephyrhills, FL 33542 ARCHITECT'S PROJECT NUMBER: 19CO29 PROJECT DESCRIPTION: 1U BEMNG W&L TENANT IMPROVEMENTS OF EXISTING, 1 STORY CMU AND STEEL ROOF STRUCTURE. EXISTING SPACE IS BUSINESS AND WILL REMAIN BUSINESS. NORTH ROOF FRAMING PLAN h" N 1/4 of 1 I -off 4/ 0 2' 4' ROOF FRAMING NOTES 1. TRUSS TYPES SHOW TRUSS PROFILE ONLY. TRUSS WEB DESIGN, BRACING, HANGERS, ETC. TO BE BY TRUSS MANUFACTURE. TRUSS MANUFACTURE TO PROVIDE ENGINEERED DESIGN AND ERECTION DRAWINGS. DIMENSIONS ARE NOMINAL. TRUSS MANUFACTURE TO VERIFY ALL DIMENSIONS, LAYOUT AND TRUSS CONFIGURATIONS. TRUSSES SHALL BE DESIGNED IN ACCORDANCE WITH THE TPI DESIGN SPECIFICATION FOR METAL PLATE CONNECTED WOOD TRUSSES. 2. ROOF SHEATHING TO BE 15/32' EXPOSURE I COX PLYWOOD STAGGER ENO JOINTS - USE PLY CLIPS ON ALL UNSUPPORTED EDGES FASTEN WITH Bd RING -SHANK NAILS AT 6' D.C. AT EDGES AND INTERMEDIATE FRAMING. 3. DIMENSIONS ARE NOMINAL. TRUSS MANUFACTURER TO VERIFY ALL DIMENSIONS, LAYOUT AND TRUSS CONFIGURATIONS. 4. TRUSSES SHALL BE DESIGNED IN ACCORDANCE WITH THE TPI DESIGN SPECIFICATION FOR METAL PLATE CONNECTED WOOD TRUSSES. 5. VERIFY ALL BEARING CONDITIONS WITH TRUSS MANUFACTURER 6. PROVIDE BRIDGING /BRACING AS REQUIRED BY TRUSS ERECTION DRAWINGS 7. ROOF SHEATHING TO BE 15/32' EXPOSURE 1 COX PLYWOOD STAGGER ENO JOINTS - USE PLY CLIPS ON ALL UNSUPPORTED EDGES FASTEN WITH Bd RING -SHANK NAILS AT 6' O.C. AT EDGES AND INTERMEDIATE FRAMING. LEGEND: M EXIT SIGN WITH BATTERY PACK #E FIRE EXTINGUISHER & WALL BRACKET DIRECTION OF TRAVEL PATH OF EGRESS WALL MOUNTED EMERGENCY LIGHT SCOPE OF WORK INCLUDES DEMOLITION OF EXISTING INTERIOR WALLS, INSTALLATION OF NEW NEW INTERIOR WALLS, NEW ELECTRICAL RUNS, NEW CEILING GRID, NEW PLUMBING, NEW FIXTURES, NEW FLOORING AND NEW DOORS. BUILDING DATA: SQUARE FOOTAGES: NEW BUILD SQUARE FOOTAGE: 480 SQ FT EXISTING BUILDING SQUARE FOOTAGE: XXXXX SQFT CODE DATA: FLORIDA BUILDING CODE, SIXTH EDITION 2017 FLORIDA ACCESSIBILITY CODE, SIXTH EDITION 2017 FLORIDA MECHANICAL CODE, SIXTH EDITION 2017 FLORIDA PLUMBING CODE, SIXTH EDITION 2017 FLORIDA EXISTING BUILDING CODE, SIXTH EDITION 2017 FLORIDA FIRE PREVENTION CODE, SIXTH EDITION 2017 NFPA 70, NATIONAL ELECTRICAL, 2017 This plan has been reviewed using the currently adopted Florida Building Code (FBC) 2017, 6th Edition. This plan has been reviewed using the currently adopted Fire Prevention Code (FFPC) 6th Edition, Florida Administrative Code (FAC) and Florida State Statute (FSS) FLORIDA EXISTING BUILDING CODE SIXTH EDITION, 2017 SECTION 301 COMPLIANCE 301.1 GENERAL, Exception: 1 Subject to the approval of the code official, alterations complying with the laws in existence at the time the building or the affected portion of the building was built shall be considered in compliance with the provisions of this code OCCUPANCY (FBQ CHAPTER 3): ASSEMBLY - GROUP A-2 BUILDING HEIGHT LIMITATIONS (FBQ TABLE 504.3): TYPE Ill -A (NON -SPRINKLED) ALLOWABLE: PROVIDED: 65' 15-0" E N/A N/A 3 1 E MAX HEIGHT HEIGHT INCREAS (SECTION 504.2) MAX STORIES STORY INCREAS (SECTION 504.2) BUILDING AREA LIMITATIONS (FBC TABLE 504.3L MAX AREA 1 480 sf 14,000 sf I N/A TYPE OF CONSTRUCTION (FBC CHAPTER 6): TYPE 111-A FIRE -RESISTANCE RATING FOR BUILDING ELEMENTS: (TABLE 601) BUILDING ELEMENT TYPE III - PRIMARY STRUCTURAL FRAME BEARING WALLS EXTERIOR 2 INTERIOR NA NON -BEARING WALLS AND PARTITIONS (INTERIOR) 0 FLOOR CONSTRUG-HOW-TRD-- SECONDARY MEMBERS 1 ROOF CONSTRUCTION AND 1 SECONDARY MEMBERS A MINIMUM PLUMBING FACILITIES (FPC CHAPTER Al ASSEMBLY, XX PERSONS - PER FLOOR (TABLE 403.1) OCCUPANCY: (Section 309) ASSEMBLY A-2. OCCUPANT LOAD (Table 1004.1.2) OCCUPANCY CLASSIFICATION PER OCCUPANT AREA OCCUPANT LOA ASSEMBLY 15 NET XXXX SF XX 1: OCCUPANT LOAD BASED ON ATTACHED RESTAURANT MEANS OF EGRESS (FBC CHAPTER 10) SPRINKLERED, A-2 OCCUPANCY VIDED t�lm 1 r_%.7Vr11 1 mr-wUlmr-u rMu MAXIMUM TRAVEL 200 FT 21 F_ DISTANCE (TABLE 1017.2) MAXIMUM DEAD-END 50 FT N/A CORRIDOR (FBC 1018.4) TOTAL # OF EXITS (SECTION 1006.3.1) COMMON PATH OF EGRESS TRAVEL 75' N/A (SECTION 1014.3, EXCEPTION 1) EGRESS STAIR WIDTH PER N/A N/A LEVEL (SECTION 1005.1) OTHER EGRESS WIDTH PER 18" N/A LEVEL (SECTION 1005.1) 87x(O.2)=18" MINIMUM CORRIDOR AISLE WIDTH 44" N/A (TABLE 1018.2) EXIT PASSAGE WAY FIRE N/A N/A RATING (SECTION 1023.3) 1 C MINIMUM CLEAR OPENING OF EXIT 32" 32" DOORS (SECTION 1008.1.1) INTERIOR FINISHES (TABLE 803.9): OCCUPANCY EXIT ENCLOSURES CORRIDORS1 ROOMS AND AND PASSAGEWAYS ENCLOSED SPACES GROUP A CLASS A CLASS A I CLASS B CORRIDOR FIRE RESISTANCE RATING: (FROM TABLE 1018.1) OCCUPANCY OCCUPANT FIRE RESISTANCE CLASSIFICATION LOAD RATING (SPRINKLERED ASSEMBLY 92 PERSONS NA 4TEGORY MALE WATER CLOSETS 1: 75 FEMALE WATER 1 CLOSETS 1: 75 LAVATORIES 1:200 DRINKING FOUNTAINS SERVICE ISINK REQU IREDIPROVIDEDIREQUI REDIPROVIDED REQUI REDI PROVIDED REQU IREDIPRO\,A DEDIREQU IREDI PROVIDED 1 4 3 2 5 0 0 • URINALS- SUBSTITUTION OF URINAL FOR WATER CLOSET (FPC SECTION 419.2) • WATER FOUNTAINS - 0 REQUIRED (FPC SECTION 410.4) M 0 M co E 0 0 0 0_ U > 00 Pr) UJ �- re) cz) M U) r�_ U') U-) LL� C14 Cn CP C:) m C�l V) V) C) 0 L.0 0N n'_ C5 V) L0 "d: C) C:) 00 1J_ (7) C_ 0 0 7D Cn 0 C-) Li-i LJ_ I Cn CN 4- LO C_ U LL_ !E L_ CL Q) CD (D m C- r*0 C) Lr) 8d LLJ P _J < n < pe) C14 ir F- X.: .0 LLI LL _J OW CL �! 0 0 C-) Cr F_ LLI C-) 0 (n 1 "1" U-) (A 5: _J W 19CO29 review approval permit 07-29-2019 revision revision S-100 GENERAL NOTES 1. THE CONTRACTOR SHALL VISIT THE SITE AND BECOME FAMILIAR WITH SITE CONDITIONS AS THEY MAY AFFECT CARRYING OUT THE WORK AS DESCRIBED IN THESE CONTRACT DOCUMENTS. THE CONTRACTOR SHALL INVESTIGATE, VERIFY, AND BE RESPONSIBLE FOR ALL CONDITIONS OF THE PROJECT, AND NOTIFY THE ARCHITECT OF ANY CONDITIONS THAT REQUIRE MODIFICATION BEFORE PROCEEDING WITH THE WORK. 2. ARCHITECTURAL DRAWING NOTATION INCLUDES SPECIFICATION SECTION REFERENCE NUMBERS IN CONJUNCTION WITH MATERIAL DESCRIPTIONS. THIS INFORMATION IS PROVIDED FOR THE CONVENIENCE OF THE CONTRACTOR ONLY AND IS NOT INTENDED TO INDICATE SPECIFIC TRADES TO BE UTILIZED FOR THE WORK. IN CASE OF DISCREPANCIES BETWEEN THE REFERENCE NUMBER AND THE VERBAL DESCRIPTION, THE VERBAL DESCRIPTION SHALL TAKE PRECEDENCE, UNLESS OTHERWISE DIRECTED. DISCREPANCIES BETWEEN SPECIFICATION NUMBER REFERENCES AND WRITTEN DESCRIPTIONS OF MATERIALS OR SYSTEMS IN NO WAY RELIEVES THE CONTRACTOR OF RESPONSIBILITY FOR THE COMPLETING OF THE WORK AS SHOWN. 3. DIMENSIONS INDICATED ARE TO FACES OF STRUCTURE AND GRID LINES (TYPICAL), UNLESS NOTED OTHERWISE. 4. REFER TO ENLARGED PLANS FOR DIMENSIONS, DETAIL REFERENCES, AND INTERIOR ELEVATION REFERENCES WITHIN THOSE AREAS. 5. REFER TO STRUCTURAL, MECHANICAL, PLUMBING, AND ELECTRICAL FOR ADDITIONAL GENERAL NOTES, ABBREVIATIONS, AND SYMBOLS. ALL NOTES ARE TO BE REVIEWED, AND APPLIED TO RELATED BUILDING COMPONENTS. DETAILS NOT SHOWN ARE SIMILAR IN CHARACTER TO THOSE THAT ARE SHOWN. WHERE SPECIFIC DIMENSIONS, DETAILS, OR DESIGN INTENT CANNOT BE DETERMINED OR REASONABLY INFERRED, CONSULT THE ARCHITECT BEFORE PROCEEDING WITH THE WORK. REFER TO STRUCTURAL DRAWINGS FOR STRUCTURAL COLUMN AND BEARING WALL LOCATIONS AND SIZES. 6. REFER TO DETAIL SHEET FOR PARTITION TYPES, DETAILS, AND DESCRIPTIONS. 7. REFER TO REFLECTED CEILING PLANS FOR SOFFIT LOCATIONS AND CEILING DETAIL REFERENCES. B. WHERE DOORS IN METAL STUO/GYPSUM BOARD PARTITIONS ARE NOT SPECIFICALLY LOCATED ON THE PLANS WITH DIMENSION STRINGS, PROVIDE A MINIMUM HINGE -SIDE JAMB DIMENSION OF 6' FROM DOOR OPENING TO ADJACENT PERPENDICULAR WALLS. WHERE DOORS APPEAR TO BE CENTERED WITHIN CORRIDORS, LOCATE THE DOORS IN THE CENTER OF THE CORRIDOR. 9. TOP OF CONCRETE FINISH FLOOR (LEVEL ONE) IS ASSUMED AT EI. 100'-0. 10. DRAWINGS ARE PREPARED USING DIMENSIONS AND PRODUCT CONFIGURATIONS OR DETAILS OF SPECIFIC MANUFACTURERS (TYPICALLY THE FIRST MANUFACTURER LISTED UNDER 'ACCEPTABLE MANUFACTURERS' IN THE SPECIFICATIONS). DIMENSIONS AND DETAILS FOR SPECIFIC PRODUCTS MAY CHANGE BEFORE THEY ARE ACTUALLY INCORPORATED INTO THE WORK, AND PRODUCTS BY OTHER MANUFACTURERS MAY ALSO BE ACCEPTABLE. THEREFORE, ACTUAL INSTALLATION DETAILS AND DIMENSIONS MAY DIFFER FROM THOSE SHOWN. CONTRACTOR SHALL VERIFY INSTALLATION REQUIREMENTS FOR ALL PRODUCTS TO BE INCORPORATED IN THE WORK (INCLUDING PARTITION THICKNESSES FOR RECESSED OR SEMI -RECESSED PRODUCTS), AND IS RESPONSIBLE FOR ACCOMMODATING AND COORDINATING CHANGES TO OTHER MATERIALS OR PRODUCTS THAT ARE NECESSARY BECAUSE OF THESE DIFFERENCES. 11. PARTITION TYPES CONTINUE AROUND CORNERS UNLESS INDICATED OTHERWISE. 12. THE DRAWINGS AND SPECIFICATIONS ARE SEPARATED INTO DISCIPLINES FOR THE CONVENIENCE OF THE ARCHITECT AND THE CONTRACTOR. THE SEPARATIONS USED HEREIN ARE USED ONLY FOR THE PURPOSES OF CONVENIENCE AND REFERENCE AND IN NO WAY DO THEY DEFINE OR LIMIT THE SCOPE OR INTENT OF ANY PART OF THE DRAWINGS, OR OF THE DRAWINGS AND SPECIFICATIONS AS A WHOLE. THE FACT THAT THE DRAWINGS ARE SEPARATED IN NO WAY SUGGESTS THAT THE WORK IS NOT TO BE CONSTRUCTED AS A COMPLETE, INTEGRATED AND UNIFIED WHOLE. 13. THE DRAWINGS AND SPECIFICATIONS, INCLUDING DRAWINGS PREPARED BY SPECIFIC ENGINEERING DISCIPLINES (SUCH AS CIVIL, STRUCTURAL, MECHANICAL, ELECTRICAL, ETC.) ARE COMPLEMENTARY; ITEMS SHOWN IN ANY ONE LOCATION IN THE DRAWINGS SHALL BE CONSIDERED TO BE REQUIREMENTS OF THE CONTRACT FOR CONSTRUCTION. IN THE EVENT OF AN INCONSISTENCY BETWEEN THE DRAWINGS AND SPECIFICATIONS, OR WITHIN EITHER DOCUMENT, THE CONTRACTOR SHALL SEEK CLARIFICATION OR INTERPRETATION FROM THE ARCHITECT PRIOR TO BIDDING. WHERE INCONSISTENCIES ARE NOT CLARIFIED PRIOR TO BIDDING, AND WHERE THE ACTUAL SOLUTION OR INTENT CANNOT BE REASONABLY INFERRED, THE CONTRACTOR SHALL INCLUDE THE BETTER QUALITY OR GREATER QUANTITY OF WORK IN THE BID PROPOSAL. 14. WALL, CEILING, BASE, AND FLOOR FINISHES ARE TO BE PROVIDED IN EVERY ROOM UNLESS THE DRAWINGS SPECIFICALLY INDICATE THAT A ROOM OR PORTION THEREOF IS TO REMAIN 'UNFINISHED.' IF ROOM FINISHES ARE NOT SPECIFICALLY INDICATED, PROVIDE THE SAME FINISHES AS ARE PROVIDED IN THE ROOM ADJACENT TO THE ROOM IN QUESTIONS, OR OBTAIN CLARIFICATION FROM THE ARCHITECT PRIOR TO BIDDING. 15. FIRE-RATEO CORRIDOR PARTITIONS INDICATED ON FLOOR PLANS ARE COMPONENTS OF CONTINUOUS RATED CORRIDOR ASSEMBLIES CONSISTING OF WALLS, FLOOR, AND CEILING. SEE REFLECTED CEILING PLANS AND PARTITION TYPES FOR SPECIFIC METHODS OF ACHIEVING THE NECESSARY RATINGS. WHERE THE SPECIFIC METHOD OF ACHIEVING THE RATING IS NOT INDICATED, OBTAIN CLARIFICATION FROM THE ARCHITECT PRIOR TO BIDDING. THE RATING OF THE ENTIRE CORRIDOR MUST BE MAINTAINED. PROVIDE RATED PARTITIONS, FLOORS CEILINGS, AND DOOR OR OTHER OPENING ASSEMBLIES TO MAINTAIN THE CONTINUITY OF THE FIRE RATING. PROVIDE FIRE SAFING AND FIRE -RATED SEALANTS TO MAINTAIN THE CONTINUITY OF THE FIRE -RATED SYSTEM. IF A CEILING RATING IS NOT SPECIFICALLY INDICATED, OBTAIN CLARIFICATION FROM THE ARCHITECT PRIOR TO BIDDING; OTHERWISE, ASSUME A RATING TO MATCH THE RATING OF THE CORRIDOR WALLS. WHERE MECHANICAL WORK PENETRATES ANY COMPONENT OF THE FIRE -RATED ASSEMBLY, PROVIDE THE APPROPRIATE FIRE ANO/OR SMOKE DAMPERS. IF IT IS NOT CLEAR WHETHER OUCTWORK PENETRATES A PORTION OF THE RATED ASSEMBLY, OBTAIN CLARIFICATION FROM THE ARCHITECT PRIOR TO BIDDING. 16. DOOR ASSEMBLIES IN I -HOUR RATED PARTITIONS ARE TO BE 20-MINUTE RATED UNLESS A HIGHER RATING IS INDICATED IN THE DOOR SCHEDULE. 17. DOOR ASSEMBLIES IN 2-HOUR RATED PARTITIONS ARE TO BE 90-MINUTE RATED UNLESS A HIGHER RATING IS INDICATED IN THE DOOR SCHEDULE. le. USE TEMPERED GLASS IN ALL OPENINGS WITHIN 18' OF THE FLOOR OR A DOOR, UNLESS ANOTHER FORM OF SAFETY GLAZING IS SPECIFICALLY INDICATED ON THE DRAWINGS. 19. USE WIRE -GLASS IN ALL GLAZED OPENINGS WITHIN FIRE -RATED CORRIDORS. 20. CAULK ALL JOINTS OR CRACKS WHICH OCCUR WHERE DISSIMILAR MATERIALS INTERSECT PERPENDICULAR TO EACH OTHER, AND THE INTERSECTION IS EXPOSED TO VIEW, UNLESS INDICATED OTHERWISE ON THE DRAWINGS. 21. PROVIDE SLIP JOINT CONNECTIONS AT THE TOPS OF ALL PARTITIONS WHICH INTERSECT THE STRUCTURE ABOVE; PROVIDE FIRE-SAFING AT ALL SLIP -JOINT CONNECTIONS IN FIRE-RATEO PARTITIONS. SEE PARTITION TYPES FOR TYPICAL SLIP -JOINT CONNECTION DESIGN. IF AMOUNT OF DEFLECTION TO BE ACCOMMODATED IS NOT INDICATED, OBTAIN CLARIFICATION FROM THE ARCHITECT PRIOR TO INSTALLATIONS. 22. PAINT ALL EXPOSED STEEL OR WOOD (UNLESS NOTED OTHERWISE). 23. ALL MATERIAL COLORS TO BE SELECTED BY ARCHITECT, UNLESS NOTED OTHERWISE. 24. M.O. (MASONRY OPENING) REFERS TO NOMINAL MASONRY OPENING DIMENSIONS IN MASONRY CONSTRUCTION. 6"n-ax 36" min 1* J* J* 54"min .00 10 .4 0* �04# 0* 18 - -,-\ 09� 42"Min 70e .0 GENERAL NOTES MEP MOUNTING HEIGHTS ABBREVIATIONS 1. INFORMATION CONTAINED ON THESE DRAWINGS WITH REGARD TO EXISTING ELECTRICAL GENERAL: A.B. ANCHORBOLT K.O. KNOCK OUT CONDITIONS OF CONSTRUCTION IS PROVIDED FOR THE CONVENIENCE OF THE MOUNTING HEIGHTS INDICATED APPLY FOR GENERAL CONDITIONS UNLESS NOTED OTHERWISE A.C.T. ACOUSTICAL CEILING TILE LAB. LABORATORY GENERAL CONTRACTOR IN EXECUTING THE WORK. EVERY ATTEMPT HAS BEEN (DIMENSIONS REPRESENT DISTANCE ABOVE FINISH FLOOR TYPICAL). IF CONFLICTS ARISE, A/C AIR CONDITIONER LAM. LAMINATE(0) MADE TO PROVIDE COMPLETE AND ACCURATE REPRESENTATIONS OF SUCH REVIEW WITH ARCHITECT PRIOR TO INSTALLATION OF BACK BOXES OR FRAMING; MODIFY ADJ. ADJUSTABLE LAV. LAVATORY EXISTING CONDITIONS. THIS INTERPRETATION HAS BEEN TAKEN FROM RECORD THESE HEIGHTS AS NECESSARY TO CONFORM TO ADA REQUIREMENTS, LOCAL CODE. A.F.F. ABOVE FINISH FLOOR LB.(s) POUNO(S) SETS OF 'AS -BUILT' DRAWINGS ON FILE FROM THE OWNER AND HAS BEEN ALT. ALTERNATE L.F. LINEAR FOOT FURTHER SUPPLEMENTED BY FIELD -MEASUREMENT AND OBSERVATIONS. THE ELECTRICAL ITEM MOUNTING HEIGHT: ALUM. ALUMINUM LGT. LENGTH ARCHITECT CANNOT AND DOES NOT GUARANTEE THE ACCURACY OF ANY SUCH A.P. ACCESS PANEL L.H. LEFT HAND INFORMATION AND ASSUMES NO LIABILITY THEREFORE. ACCESS PANEL @ WATER WALLS: 2'-0 AFF TO CENTER OF UNIT APPROX. APPROXIMATE LIN. LINEN DRINK FOUNTAIN OR ELECTRIC WATER COOLER: ARCH. ARCHITECTURAL LKR. LOCKER 2. THE INFORMATION CONTAINED ON THESE DRAWINGS WITH REGARD TO EXISTING @ ACCESSIBLE: 3'-0' TO SPOUT A.S. ABOVE SLAB LT. LIGHT CONDITIONS OF CONSTRUCTION IN NO WAY RELEASES THE GENERAL CONTRACTOR @ STANDARD: 3'-6' TO SPOUT AUTO. AUTOMATIC MAINT. MAINTENANCE FROM THE RESPONSIBILITY FOR VERIFYING COMPLETELY ALL FIELD CONDITIONS MARKERBOARDS/TACKBOAROS: 3'-0 TO BOTTOM RAIL B/ BOTTOM OF MAS. MASONRY RELATING TO AND AFFECTING THE EXECUTION OF THE WORK, AS DESCRIBED IN THERMOSTATS: 5'-0' AFF TO CENTER BO. BOARD MATL. MATERIAL THESE CONTRACT DOCUMENTS. ELECTRICAL RECEPTACLE: 1'-6', OR 4' ABOVE COUNTER AND BLDG. BUILDING MAX. MAXIMUM BACKSPLASH, OR CENTER IN SPACE BKL. BLOCK MECH. MECHANICAL 3. IT IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO FIELD VERIFY AND PROVIDED WHEN USED WITH BKLG. BLOCKING MEZZ. MEZZANINE DOCUMENT ALL EXISTING DIMENSIONS, ELEVATIONS AND BENCHMARKS, MATERIALS COUNTERTOP & CABINETS ABOVE. BM. BEAM MFR. MANUFACTURER AND METHODS OF CONSTRUCTION THAT MAY AFFECT OR BE AFFECTED BY NEW B.M. BENCH MARK MGMT. MANAGEMENT WORK, AND TO COORDINATE SUCH FIELD VERIFICATION WITH THE CONTRACT ELECTRICAL AND COMMUNICATIONS RECEPTACLES: BOT. BOTTOM MIN. MINIMUM DOCUMENTS AND THE EXECUTION OF THE WORK. DISCREPANCIES AND/OR @ WALL MOUNTED TV: 7'-B' TO CENTER B.S. BOTH SIDES misc. MISCELLANEOUS CONFLICTS INVOLVING ANTICIPATED EXISTING CONDITIONS SHALL BE 13ROUGHT @ COMMUNICATIONS RECEPTACLE: l'-6', OR 4' ABOVE TOP OF COUNTER OR B.T.B. BACK TO BACK M.O. MASONRY OPENING TO THE ARCHITECT'S ATTENTION IMMEDIATELY. BACKSPLASH, TO CENTER B.U.R. BUILT UP ROOFING M.R. MOISTURE RESISTANCE CAB. CABINET MTO. MOUNTED 4. FIELD- VERIF IC ATI ON OF EXISTING CONDITIONS RELATED TO SPECIFIC PORTIONS C.B. CATCH BASIN MTG. MOUNTING OF THE WORK SHALL BE UNDERTAKEN IN ADVANCE TO ALLOW FOR THE TIMELY ELECTRICAL SWITCH: 3'-B' TO CENTER CCTV. CLOSED CIRCUIT TELEVISION MTL. METAL IDENTIFICATION OF EXISTING CONDITIONS THAT MAY AFFECT THE SCHEDULED FIRE ALARM PULL STATION: 3'-B' TO CENTER C.G. CORNER GUARD MUL. MULLION INSTALLATION OF NEW WORK AS DESIGNED AND DETAILED, AND TO AVOID UNDUE FIRE EXTINGUISHER CABINET: 3'-4' TO BOTTOM C.J. CONTROL JOINT N.I.C. NOT IN CONTRACT AND UNREASONABLE DELAYS TO THE PROJECT SHOULD SUCH CONDITIONS BE FIRE HORN DEVICE: 7'-B' TO CENTER C.L. CENTER LINE NO. NUMBER DISCOVERED. TIMELY IDENTIFICATIONS OF SUCH CONDITIONS SHALL PROVIDE CLOCK & WALL MOUNTED SPEAKER: 7'-0' AFF TO CENTERLINE OF UNITS CLG. CEILING NOM. NOMINAL FOR A MINIMUM PERIOD OF TEN (10) WORKING DAYS DURING WHICH TIME THE AUTOMATIC DOOR OPERATOR: 3'-0' TO CENTER CLO. CLOSET N.T.S. NOT TO SCALE ARCHITECT WILL EVALUATE THE CONDITIONS AND MAKE RECOMMENDATIONS FOR MAGNETIC DOOR HOLDER: 6'-4' TO CENTER CLR. CLEAR O.A. OVERALL ACCOMMODATING NEW WORK. PANIC HARDWARE: 3'-0' TO CENTER CLS. CLOSURE D.C. ON CENTER ROOM SIGNAGE: 60' TO CENTER, 2' AWAY FROM LATCH SIDE C.M. CONSTRUCTION MANAGER 0.0. OUTSIDE DIAMETER 5. IT IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO ASSIST THE JAMB C.M.U. CONCRETE MASONRY UNIT OFF. OFFICE ARCHITECT IN MAKING THEIR EVALUATIONS AND RECOMMENDATIONS BY PROVIDING PLUMBING GENERAL: COL. COLUMN OH. OVERHEAD IN A TIMELY MANNER, AT NO ADDITIONAL COST TO THE OWNER, ACCURATE AND CONC. CONCRETE OPP. OPPOSITE COMPLETE DRAWINGS, SKETCHES, AND PHOTOGRAPHS SUFFICIENT TO CLEARLY MOUNTING HEIGHTS INDICATED APPLY FOR TYPICAL CONDITIONS UNLESS NOTED OTHERWISE CONF. CONFERENCE OPP.H. OPPOSITE HANG DESCRIBE DISCREPANCIES, CONFLICTS, AND CONCEALED OR OTHERWISE (DIMENSIONS ARE ABOVE FINISH FLOOR (AFF) TYPICAL). IF CONFLICTS ARE DISCOVERED CONT. CONTINUOUS O.T.O. OUT TO OUT UNANTICIPATED EXISTING CONDITIONS AFFECTING NEW CONSTRUCTION. THE REVIEW WITH ARCHITECT PRIOR TO INSTALLATION OF BACK BOXES OR FRAMING. CONFIRM' C , P , CONTROL PANEL P.A. PUBLIC ADDRESS GENERAL CONTRACTOR SHALL FURTHER ASSIST THE ARCHITECT BY PROVIDING IN AND MODIFY THESE HEIGHTS AS NECESSARY TO CONFORM TO ADA REQUIREMENTS OR, LOCAL CPT. CARPET PART. PARTITION A TIMELY MANNER PREPARED SOLUTIONS TO UNANTICIPATED EXISTING CODES. CORR. CORRIDOR PAV. PAVEMENT CONDITIONS. C.T. CERAMIC TILE P.C. PRECAST cu. CUBIC PFB. PREFABRICATE(D) 6. THE ARCHITECT HAS ENDEAVORED TO IDENTIFY AS COMPLETELY AS POSSIBLE IN PLUMBING ITEM MOUNTING HEIGHT C.W. COLD WATER PFN. PREFINISHED THE DRAWINGS AND SPECIFICATIONS EXISTING ITEMS OF EQUIPMENT AND LAVATORY: 34' TO RIM OR COUNTER DBL. DOUBLE PL. PLATE CONSTRUCTION THAT ARE REQUIRED TO BE REMOVED OR OTHERWISE DEMOLISHED WATER CLOSET: DEMO. DEMOLISH PLWO. PLYWOOD SO AS TO ALLOW THE EXECUTION OF NEW WORK. THIS INFORMATION IS @ ACCESSIBLE: 17' TO 19' TO TOP OF SEAT DEPT. DEPARTMENT PR. PAIR PROVIDED FOR THE CONVENIENCE OF THE GENERAL CONTRACTOR, AND IS IN NO @ STANDARD: 14' - 15' TO RIM OET. DETAIL PROP. PROPERTY WAY INTENDED TO MEAN THAT DEMOLITION IS LIMITED ONLY TO THOSE ITEMS URINAL: O.F. DRINKING FOUNTAIN P.S. PULL STATION SPECIFICALLY IDENTIFIED. IT IS THE GENERAL CONTRACTOR'S RESPONSIBILITY @ ACCESSIBLE: 17' TO RIM OIA. DIAMETER P.S.F. POUNDS PER SQUARE FOOT TO EXECUTE DEMOLITION WORK AS REQUIRED TO ALLOW THE EXECUTION OF NEW @ STANDARD: 24' TO RIM OIAG. DIAGONAL P.S.I. POUNDS PER SQUARE WORK. MIRROR: 40' TO BOTTOM DIM. DIMENSION INCHES SOAP DISPENSERS AT LAVATORIES: 40' TO BOTTOM OISP. DISPENSER P.T. PRESSURE TREATED 7. ALL AREAS ABOVE OR ON THE EXISTING CEILING THAT ARE AFFECTED BY PAPER TOWEL DISPENSER: 40' TO BOTTOM Div. DIVISION PTO. PAINTED INSTALLATION OF NEW WORK SHALL BE REPAIRED COMPLETELY WITH MATERIALS HAND DRYER: 40' TO OPERATIONAL CONTROLS ON. DOWN Q.T. QUARRY TILE AND PRODUCTS TO MATCH EXISTING INSTALLATION AND FIRE -RATED ASSEMBLIES. NAPKIN DISPENSER: 40' TO OPERATIONAL CONTROLS 0.0. DOOR OPENING OTY. QUANTITY NAPKIN DISPOSAL: 24' TO CENTER OP. DAMPPROOFING R. RISER B. ALL ITEMS INDICATING CONTRACT LIMITS AND LINES OF DEMARCATION ARE HAND HELD SHOWER HEAD: 6'-6' TO CENTER, ON 60' HOSE DR. DOOR RAO. RADIUS SHOWN FOR THE CONVENIENCE OF THE GENERAL CONTRACTOR, AND ARE NOT TO SHOWER SEAT: 17' OTL. DETAIL R.C.P. REFLECTED CEILING PLAN BE TAKEN LITERALLY. ACTUAL CONTRACT LIMITS ARE TO BE DETERMINED BY SHOWER CONTROL: 42' TO CENTER OW. DISH WASHER R.O. ROOF DRAIN THE GENERAL CONTRACTOR PRIOR TO BID OPENINGS BY FIELD VERIFICATION. SHOWER ROD: 6'-G' TO CENTER OWG. DRAWING REC. RECESSED THE GENERAL CONTRACTOR IS RESPONSIBLE FOR ENSURING PROPER INTERFACE GRAB BAR: 36' TO CENTER EA. EACH RECEP. RECEPTION BETWEEN EXISTING AND NEW WORK. MOP HOLDER: 72' TO TOP E.F.S. EXTERIOR FINISH SYSTEM REF. REFERENCE E.I.F.S. EXTERIOR INSULATION FINISH REFR. REFRIGERATOR 9. THE GENERAL CONTRACTOR MUST BE AWARE THAT CONSTRUCTION IN SOME AREAS SYSTEM REINF. REINFORCED SURROUNDING THE LIMITS OF THIS CONTRACT IS CURRENTLY IN PROGRESS. FOR MATERIAL & FINISH NOTES E.J. EXPANSION JOINT REO'O. REQUIRE THIS REASON, ACTUAL EXISTING CONDITIONS MAY VARY FROM CONDITIONS ELEV. ELEVATION REV. REVISION INDICATED ON THESE DRAWINGS. ALL SUCH DISCREPANCIES SHALL BE 1. REFER TO CIVIL DRAWINGS FOR SITE GRADING; REFER TO ARCHITECTURAL SITE ELEV. ELEVATOR R.H. RIGHT HAND ACCURATELY AND THOROUGHLY RECORDED BY THE GENERAL CONTRACTOR AND PLAN AND ENLARGED SITE PLANS FOR CONCRETE PAVING PATTERNS AND SPOT ELEC. ELECTRICAL RM. ROOM PROMPTLY REPORTED TO THE ARCHITECT. ELEVATIONS. EMER. EMERGENCY R.O. ROUGH OPENING ENCL. ENCLOSURE S.C. SOLID CORE 10. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR IDENTIFYING ALL SIGNAGE AND 2. STRUCTURAL STEEL OR PRECAST CONCRETE SHAPES ARE SHOWN FOR DETAILING ENT. ENTRANCE SCHED. SCHEDULE OTHER ASSEMBLIES THAT MAY BE AFFECTED BY DEMOLITION OR INSTALLATION OF OF ARCHITECTURAL FINISHES ONLY; REFER TO STRUCTURAL DRAWINGS FOR E.P. ELECTRICAL PANEL S.D. SOAP DISPENSER NEW WORK. SUCH PROJECT ELEMENTS SHALL BE REMOVED AND STORED PRIOR STRUCTURAL DIMENSIONS, SIZES, SHAPES, AND DETAILS OF CONSTRUCTION FOR EQ. EQUAL SECT. SECTION TO THE PERFORMANCE OF ANY WORK. THE CONTRACTOR IS RESPONSIBLE FOR SPECIFIC CONDITIONS. EQUIP. EQUIPMENT S.F. SQUARE FOOT(FEET) CATALOGING EACH ELEMENT AND ITS LOCATION IN THE BUILDING, AND IS EXH. EXHAUST SHR. SHOWER RESPONSIBLE FOR REINSTALLING EACH ELEMENT IN ITS ORIGINAL LOCATION 3. REFER TO FINISH SCHEDULE AND INTERIOR ELEVATIONS FOR ALL WALL, EXIST. EXISTING SHT. SHEET AFTER ALL WORK IN THE AREAS HAS BEEN COMPLETED. CEILING, FLOOR, AND BASE MATERIALS AND FINISH DESIGNATIONS. EXP. EXPANSION Sim. SIMILAR EXT. EXTERIOR SPEC. SPECIFICATION 11. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR IDENTIFYING ANY UNFINISHED 4. REFER TO REFLECTED CEILING PLANS AND CEILING DETAILS FOR CEILING F/ FACE OF S.S. STAINLESS STEEL WALL AREAS THAT MAY BE EXPOSED AS A RESUL- OF ADJUSTING FINISHED HEIGHTS, SOFFIT HEIGHTS, AND MATERIALS OF CONSTRUCTION. F.A. FIRE ALARM STO. STANDARD CEILING HEIGHTS. THE CONTRACTOR IS RESPONSIBLE FOR FINISHING THESE F.D. FLOOR DRAIN STL. STEEL AREAS TO MATCH EXISTING ADJACENT FINISHED AREAS AND FIRE -RATED 5. FLASHING, DAMPPROOFING, AND INSULATIONS SHOWN ON WALL SECTIONS F.E. FIRE EXTINGUISHER STOR. STORAGE ASSEMBLIES. INDICATE VERTICAL LOCATIONS ONLY; PROVIDE CONTINUOUS SYSTEMS. F.F. FINISH FLOOR STRUC. STRUCTURAL F.H. FULL HEIGHT SUSP. SUSPENDED 12. THE GENERAL CONTRACTOR AND AFFECTED SUBCONTRACTORS SHALL VISIT THE 6. PROVIDE SEALANT AND BACKER ROOS (TYPICAL) AT ALL EXTERIOR DOOR AND F.H.C. FIRE HOSE CABINET SYM. SYMMETRICAL PROJECT SITE PRIOR TO SUBMITTING A PROPOSAL. THE CONTRACTOR SHALL WINDOW FRAMES AND LOUVERS. FIN. FINISH T/ TOP OF BECOME GENERALLY FAMILIAR WITH THE PROJECT, AND WITH THE IMPACT OF THE FL. FLOOR T. & B. TOP & BOTTOM NEW WORK ON THE EXISTING CONDITIONS. ANY AREAS OF CONCERN SHALL BE 7. REFER TO WINDOW SCHEDULE AND ELEVATIONS FOR WINDOW AND GLAZING FLASH. FLASHING T. & G. TONGUE & GROOVE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO SUBMITTING A TYPES. FLUOR. FLUORESCENT T.B.D. TO BE DETERMINED PROPOSAL. NO ADDITIONAL CHARGE TO THE OWNER WILL BE APPROVED WHICH FP FIRE PROOF TEL. TELEPHONE IS ATTRIBUTABLE TO THE CONTRACTOR'S FAILURE TO 00 THIS. B. PROVIDE FIRE -RETARDANT WOOD WHEREVER WOOD BLOCKING IS SHOWN ON THE FT. FOOT (FEET) TEMP. TEMPERED DRAWINGS. F.T.F. FACE TO FACE TER. TERRAZZO 13. THE PROJECT IS CURRENTLY OCCUPIED, AND MUST REMAIN COMPLETELY FTG. FOOTING T.O.B. TOP OF BEARING OPERATIONAL DURING NORMAL BUSINESS HOURS (7.00 A.M. TO 6:00 P.M. WEEKDAYS). 9. REFER TO MECHANICAL AND ELECTRICAL DRAWINGS FOR INTERFACES WITH THESE GA. GAUGE T.O.P. TOP OF PLATE COORDINATE WITH THE OWNER ANY CONSTRUCTION ACTIVITIES WHICH MAY SYSTEMS NOT SHOWN ON WALL SECTIONS. GALV. GALVANIZED TOPO. TOPOGRAPHY IMPEDE NORMAL OPERATIONS, INCLUDING ANY ACTIVITY WHICH OPERATES G.C. GENERAL CONTRACTOR T.O.S. TOP OF SLAB EXCESSIVE NOISE, AIRBORNE DIRT, OR WHICH DISRUPTS THE NORMAL FUNCTION 10. CONTRACTOR OR WINDOW MANUFACTURER TO DESIGN, PROVIDE AND INSTALL GEN. GENERAL T.O.STL. TOP OF STEEL OF THE SPACE. PROTECT ANY ADJACENT SPACE WITH DUST PARTITIONS OR COMPLETE ATTACHMENT OF WINDOW TO STRUCTURAL STEEL OR STRUCTURAL GNO. GROUND T.V. TELEVISION CURTAINS FROM ACTIVITIES WHICH WILL CREATE OUST. NOTIFY ANY OCCUPANTS CONCRETE, OR STRUCTURAL CONCRETE MASONRY PER SPECIFICATIONS AND GVL. GRAVEL TYP TYPICAL OF THE BUILDING OF ANY CONSTRUCTION ACTIVITIES WHICH MAY AFFECT THEIR WINDOW MANUFACTURER'S REQUIREMENTS AND IN ACCORDANCE WITH APPLICABLE GYP. GYPSUM UNF. UNFINISHED ABILITY TO OPERATE NORMALLY. CODES. GYP. 80. GYPSUM BOARD U.N.O. UNLESS NOTED OTHERWISE H. HIGH U.O.N. UNLESS OTHERWISE NOTED H.C. HOLLOW CORE UR. URINAL HDCP. HANDICAPPED V. VINYL HOW. HARDWARE VAC. VACUUM HDWO. HARDWOOD V.B. VINYL BASE H.M. HOLLOW METAL V.C.T. VINYL COMPOSITION TILE H.O. HOLD OPEN VENT. VENTILATION HORIZ. HORIZONTAL VERT. VERTICAL HR. HOUR VEST. VESTIBULE HT. HEIGHT V.I.F. VERIFY IN FIELD HTG. HEATING V.T. VINYL TILE H.V.A.C. HEATING, VENTILATING, AIR V.W.C. VINYL WALL COVERING CONDITIONER W/ WITH H.W. HOT WATER W/o WITHOUT H.W.H HOT WATER HEATER W.C. WATERCLOSET IN. INCH(ES) WD. WOOD INCAND. INCANDESCENT WDT. WIDTH INCL. INCLUDE(D) W.F. WIDE FLANGE INFO. INFORMATION W.H. WATERHEATER MOUNTING HEIGHTS INSUL. INSULATION WIN. WINDOW INT. INTERIOR W.M. WIRE MESH NOTES INV. INVERT WPFG. WATERPROOFING 1. ALL MOUNTING HEIGHTS INDICATED ABOVE ARE BASED ON 'FLORIDA BUILDING J.B. JOIST BEARING WSCT. WAINSCOT CODE, ACCESSIBILITY 2010' J.C. JANITOR'S CLOSET 2. MOUNTING HEIGHTS FOR WATER CLOSETS ARE SAME REGARDLESS IF WALL JT. JOINT MOUNTED OR FLOOR MOUNTED K.O. KNOCK DOWN KIT. KITCHEN x 0 _E bottom of ref Lective surface :z WATER GRAB WATER GRAB LAVATORY MIRROR LAVATORY CLOSET BAR CLOSET BAR x 0 E 0 E :z URINAL 36" min C TOILET TISSUE DISPENSER at GRAB BAR x 0 E 00 TOILET TISSUE DIAPER DISPENSER CHANGING STATION x 0 E DRINKING FOUNTAIN x C) E 0 E L PLAN SYMBOLS E_ WALL TYPE CED MILLWORK LABEL F00110 ROOM NUMBER LABEL DOOR NUMBER LABEL WINDOW TYPE LABEL (REVISION NUMBER AND CLOUD COLUMN BUBBLE PROPERTY LINE eLevation number 2 4 INTERIOR ELEVATION 3 drawing number eLevation number EXTERIOR ELEVATION drawing number DETAIL LOCATED ON SAME SHEET AS REFERENCE detal number DETAIL, ENLARGED PLAN, ETC. REFERENCE drawing number - section number WALL SECTION REFERENCE A-310 <5- drawing number section number BUILDING SECTION REFERENCE A-301 i - drawing number MOUNTING HEIGHTS TO BE INSTALLED AT EACH UNISEX TOILET ROOM (1 REQUIRED EACH TOILET ROOM) TYPICAL AOA COMPLIANT TOILET ROOM SIGN VENDOR SUPPLIED ITEMS - FOR REFERENCE ONL-'l` x 0 E El 00 ;:d- SOAP SANITARY DISPENSER NAPKIN DISPOSAL SANITARY NAPKIN/ TAMPON VENDORS ME 0 LO cn -0 cu L_ CL C:) 00 1`0 Ca Uj -2 Lo to C-Z 00 U-) M Uj Cr) 1`0 to L0 Lj >- M < V) C:) C:) ry V) Z:) C:) C) 0 co C14 Lrl C) L0 V) _. Elf 4� 1`10 1`0 co C) I 00 LL_ 0 Q) 0 Q.) co -4- Cn 04 .4- U-) rl") c- LL_ f- E 0- U) Cl) Q) C- C) U-) !E L) CY) 0 Pr) 04 0- �j 0 Q Ld L) Zn CD5 Ld _j ir 19CO29 review approva permit 07-29-2019 revision revision PAPER TOWEL TOILET SEAT HAND DRYER DISPENSER COVER DISPENSER G-100 0 0 0 0 SETBACK LINE 0 . ..... . ...... . . .... . . .. . . ........ ...................... . .... .... ..... ....... wo, wo, 000 d0V OOV Nb moo dOo dOO' 4ow dOo 0 oov wool wop 0 0 doop .ov oov oap 40-P mosp woo moo 0ow 000 Wow dOo soop doop dOo' 0 0 awo aoop Woo sow Wow wool woo <1 wow dow o** ow soo 0 awo doop d000 awo IN 0 0 SETBACK LINE 0 0 < > EXISTING ONESTORY MAS. & FRAME BLDG. / S . 11 ARCHITECTURAL SITE NOTES EXISTING GENERAL: PAVED PARKING SURVEY TAKEN FROM DAVID L. SMITH SURVEYING AND MAPPING INC. FIELD DATE: 05/28/19 JOB NUMBER: 1904-083 00 10 %K 0 ALL DIMENSIONS ON THIS SHEET 4.1 . : .1). CONSTRUCTION. 0 14 0 EXISTING BRICK PAVERS 0 0 Cb, <0 1 0// 0 N. 0 PROPOSED NE STORY EXISTING CMU BLD WOOD DECK cp Ae 'Pa NtrOuFR4T, SITE PLAN & PROJECT SITE 1/16 of 1 $—off 4' o 1, e, 16, EXISf ING PAVED PARKINjG' <\ MUST BE FIELD VERIFIED BEFORE "Av R 0 L_ 0 0 F�" ILWA 0 (3) pe) cc Lr) M C) 00 `0 E 0 0 10D CL > uj 0 -4.4 04 C14 W C> (n L6 LO C-4 (n cp L M (n V) Z:) U-) C:) U-) V) -4- C) �2 ao LO to 00 LO M co LO cn C) c:, C) C) co _j L.L. L U) 0 C14 L0 r1r) (a) LL_ !E L_ L 00 Q) CD -6- cf) Q-) g-- = 1c":)) 0 LO V) Lj (1) cr < F- cr c� 0 C14 WM 0 it 0 cr LLJ V) Ld cr 19CO29 review approval permit 07-29-2019 revision revision A-100 Z > LU x UWj Lun U III 0 -i M Z LLI > 20'-0" LOU 114 u l _0 - r LEI NORTH Z 0 > x Ld En 0 M Z -J LU > FLOOR PLAN LEGEND: 8' CMU WALLS TO BE CONSTRUCTED CMU VENT BLOCK 4xBx16 6' CMU PARTITION BLOCK (g=door number 103A DOOR TAG JUbd door size FLOOR PLAN it I -Off 4/ 0 21 4/ 1/4 1 20'X42 MIRROR - BOTTOM OF MIRROR TO BE 40' AFF, CENTER ON LAVATORY 00 a 1� 10 'r- 'C'4 i j 1 EXPOSED PIPES TO BE INSULATED 24'X 60' SOLID PLASTIC URINAL SCREEN FLOOR MOUNTED W/ CONTINUOUS DOUBLE EAR WALL BRACKET 28' SOLID PLASTIC STALL DOOR WITH MENS SELF CLOSING HINGES HEAVY DUTY HARDWARE L - 0 '0 I M� W 1 1 1111= 5/8' MOISTURE RESISTANT GYPSUM DRYWALL TO BOTTOM CORO OF WOOD TRUSS '00 00, LO 6"WX8"H PRECAST LINTEL— REINF W/ 1 #4 GROUT SOLID S TO BE STAINLESS STEEL, 1 1/2' SOLID PLASTIC A[ 4' TILE COVE BASE L GRAB BAR Z INA 61 CMU DIAMETER WITH TEXTURED SURFACE. GRAP BARS STALL DOOR WITH PARTITION BLOCK TO SUPPORT 250 LB VERTICAL OR HORIZONTAL 32' CLEAR OPENING LOADS. SEE SHEET A-100 FOR GRAB BAR SELF CLOSING HINGES DIMENSIONS, MOUNTING HEIGHTS AND LOCATIONS 20'X42 MIRROR - BOTTOM OF MIRROR TO BE MENS WOMENS 40' AFF, CENTER ON LAVATORY F 6"WX8"H PRECAST LINTEL REINF W/ 1#4 GROUT SOLID HM DOOR AND FRAME 12"mc]x 42"min r 0 7 Lj LGRAB BARS TO BE STAINLESS STEEL, 1 1/2' �-28' STALL DOOR WITH EXPOSED PIPES DIAMETER WITH TEXTURED SURFACE. GRAP BARS SELF CLOSING HINGES TO BE INSULATED TO SUPPORT 250 LB VERTICAL OR HORIZONTAL HEAVY DUTY HARDWARE LOADS. SEE SHEET A-100 FOR GRAB BAR DIMENSIONS, MOUNTING HEIGHTS AND LOCATIONS WOMENS TOILET ROOM ELEVATIONS __j----L 0 1/ NTS T 0 CMU VENT BL OCK w/ PAINT FINISH EXPOSED PIPES TO BE INSULATED MENS WOMENS si m i I a r NOTE: SOAP DISPENSERS, TOILET TISSUE DISPENSERS, PAPER TOWEL DISPENSERS TO BE -I PROVIDED AND INSTALLED BY OTHERS. INSTALLATION TO COMPLY WITHH ADA 3" GUIOLINES SEE SHEET A-100 0 2' 1 4' SOLID PLASTIC ADA STALL DOOR WITH 32' CLEAR OPENING SELF CLOSING HINGES 1 X 4 32W SURFACE MOUNTED LED LIGHTING FIXTURE EXIT SIGN EMERGENCY LIGHTS 0 DAYLIGHT HARVESTING CONTROLLER CEILING MOUNTED REFLECTIVE CEILING PLAN NOTES: NOTE: DRYWALL CEILING @ 10'-0' AFF SOLID PLASTIC N L REMOVABLE PANEL- SOLID PLASTIC WITH CONCEALED CLEAT Vanity Detail i"-V-0" SOLID PLASTIC TO MATCH PARTITION DOORS COUNTERTOP L SPLASH: SOLID PLASTICj X' BEVEL EDGE PROFILE. SEAL ALL EDGES AT CUTOUTS. A/C POWERED AUTOMATIC SOAP DISPENSER; LOCATED IN THE LAVATORY DECK. RAKKS COUNTER SUPPORT FACE OF FINISHED WALL 7'-3"MIN. 5'-0" clear 5'-0' cLear f r6m edge of Lavatory tq, wal.l. SEE INSTALLATION 1 6 V-1, DIMENSIONS FOR GRAB BARS AND '1 ACCESSORIES BELO'% - 0 C14 R L -p 48'X30' 0 L- 0 ,cLe r -2 c 0'0 in Aron L +o qtoifT -/- -J 0 Lov t 0 ADA TOILET ROOM PLAN e-,*) LJ Lj 0 0 U --- NORTH REFLECTED CEILING PLAN It = I -off 4/ 0 2' 4' 1/4 1 1 0 area- 1 N"�. 5'- 0 GENERAL NOTES: GENERAL: 1. THIS STRUCTURE HAS BEEN DESIGNED IN ACCORDANCE WITH THE FLORIDA BUILDING CODE 6TH EDITION 2017. 2. GENERAL CONTRACTOR IS RESPONSIBLE FOR MEETING PREVAILING BUILDING CODES, DISABILITY LAWS & CODES, FIRE CODES, MECH. & ELEC. CODES & LIFE SAFETY STANDARDS AS SHOWN ON THE PLAN. 3. SITE DIMENSIONS ARE TO BE FIELD VERIFIED. SCOPE OF WORK: 1. CONSTRUCT NEW TOILET ROOM BUILDING TO ACCOMADATE EXISTING RESTAURANT INDOOR AND OUTDOOR DINING AREAS. BUILDING TO BE CONSTRUCTED OF 8' CMU WALL AS SHOWN, CONCRETE SLAB ON GRADE AND WOOD ROOF TRUSSES WITH METAL ROOF TO MATCH EXISTING. 2. INTERIOR WALLS TO BE 8' AND 6' CMU. PARTITION DOORS TO BE SOLID PLASTIC. VANITIES TO BE SOLID PLASTIC. 3. PLUMBING AND ELECTRICAL AS SHOWN. THIS BUILDING WILL NOT BE AIR CONDITIONED. EXHAUST FANS TO BE CONTROLED WITH THERMOSTATS AND HUMIOASTATS DIMENSIONS 1. DIMENSIONS ARE NOMINAL 2. DIMENSIONS ARE SHOWN FROM FACE OF CMU WALL AND FACE OF STUD WALL 3. COORDINATE SHOWN DIMENSIONS WITH APPLIANCE DIMENSION REQUIREMENTS 4. COORDINATE SHOWN DIMENSIONS WITH FIXTURE DIMENSION REQUIREMENTS 5. COORDINATE DOOR AND WINDOW ROUGH OPENING REQUIREMENTS WITH MANUFACTURER 6. STRUCTURE TO BE FIELD VERIFY PRIOR TO MANUFACTURING OF STRUCTURAL COMPONENTS 7. WALL DIMENSIONS TO BE FIELD VERIFY PRIOR TO CONSTRUCTION OF CASEWORK WOMENS MENS simi I a r TOILET ROOM CMU PARTITIONS NTS ASS BATTS MOUNTED IN ATTIC co U-) 0 -0 !9! 2 co 0 U- 0 CL 0 - > C4 00 C14 LU LO t: C�l r- cy) Uj Lri LO C,4 NO cn >- < (n �q M c) C:) cr-- r�o r1r) C/) C) '0 C14 0 C<-' 'n L�_j Ln (n LO C) U-) CM Cle q- E 0 C) __j co Ll- 0 C-) Q.) 0 cf) C) -4- c() C14 U-) ro c- r-) ILL- = !E L- >11 _9_- cn Q) r1e) c:) U-) c/) LLJ C> -J < 0- 0 X: 'M 2 am 95 ao 00W W 0 _j Lj-- 5; W 19CO29 review 04-26-2019 approval permit 07-29-2019 revision revision A-101 c .00— rOP OF CMU WALL CMU 00 &LIMED FINISH FLOOR NORTH ELEVATION to I -Off 1/4 1 L-BRACING HEIGHT I (2) 2X4 6'-2* TO 8'-4" (1) 2X4 3'-2" TO 6'-2" NOT REQ. LESS THAN 3'-3" 2-2X6 TOP PLATE 5V CRIMP METAL ROOFING (2) 2X6 L-BRACING NAILED TO GABLE END TRUSS FOR HEIGHT - UP`rO 13'-2- (2) 2X6 L-BRACING FOR HEIGHT = uFro 9'-6" (2) 2X4 L-BRACING OR 1-2X6 30# FELT UNOERLAYMENT, FOR HEIGHT = UPTO 7' ; (1) 2X4 L-BRACING INSTALL PARALLEL TO EAVE, START AT EAVE - LAP TOP LAYER FOR HEIGHT UPTO 3'-8*; NO L-BRACE REQUIRED FOR HEIGHT < 3'-8" OVER BOTTOM 4' MIN. W/16d NAILS 0 3- O.C. ENDLAP 6' OFFSET 6' GABLE END TRUSS (HELD DOWN 3 1/2- FOR OUTLOOKER) PLYWOOD SHEATHING INSTALL 15/32- CDX PLYWOOD/11/2- OBS/ WOOD SIDING NAILED PERPENDICULAR TO WALL, W/8d NAILS 6" O.C. 0 EDGE & STAGGER JOINTS, 8D RING SHANK NAILS 6" O.C. 0 INTERMEDIIATE SUPPORTS SEE ROOF SHEATHING NAILING ZONE DETAIL L BRACING D ETAI L NTS 2X4 OUTILOOKER NOTE DROP FIRST TRUSS 0 24" O.C. 3 1/2- FOR 2X4 OUTILOOKERS X-BRACING TO BE NAILED TO 2/4 BLOCKING BRACING TO BE GRADE 2 LUMBER W/ 4-16d NAILS ON EA END 0 5- O.C. MAX ALONG GABLE END FIRST 2 FRAMING SPACES PRE ENGINEERED WD - TRUSSES 0 24* O.C. 3 TAB FIBERGLASS SHINGLES 30 LB ROOFING FELT 2X4 BLOCKING W/ 2-16d -zz_-NAILS EA END (TYP) 1/2" CDX PLYWOOD 2'-0" GABLE END 3/4 1 ALUMINUM FASCIA ON 1XIS BACKING 2X4 SUB FASCIA ALUMUNIM SOFFIT VENTED Ilk 110.9.0 ��TOP OF CMU WALL 100.00 `-FASSUMED FINISH FLOOR — — — — — — — — — — — — — — — — — — — — — — — — — - SOUTH ELEVATION _1 to $—off 4/ 0 21 4/ 1/4 1 IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY ALL DIMENSIONS & CONDITIONS PRIOR TO COMMENCING CONSTRUCTION. THIS STRUCTURE HAS BEEN DESIGNED IN ACCORDANCE WITH THE FLORIDA BUILDING CODE 7TH EDITION 2017 AND WITH ALL REVISIONS. 12 —0)) 2 4 2X4 HORZ SCAB NAILED W/ 2-16d NAILS BEYWEEN OUTLOOKERS 2 HURRICANE ANCHOR SIMPSONS H2.5 W/ 10-8d NAILS --TYP. c) METAL DRIP EDGE 'CONTINUOUS 2X4 ALUMN COVERED -VENTED SOFM 2X6 L-BRACING NAILED TO GABLE END TRUSS W/ 16d NAILS 0 3" O.C. 15/32 - CDX PLYWOOD / 7/16- OBS /WOOD SIDING NAILED W/ 8d NAILS 0 3- O.C. EDGE & 6- O.C. 0 INTERMEDIATE SUPPORTS GABLE END TRUSS (HOLD DOWN 3 1/2- FOR OUTLOOKERS) SECURE GABLE END TRUSS TO TOP PLATE W/ 16d NAILS 0 12" O.C. 2x4 WOOD BLOCKING W/ 2-16d NAILS 0 PTV"8IP2WX2- ANCHOR BOLTS 0 24- O/C 8* K/O BLOCK TIE -BEAM - REINIF W/ (2) #5 VERTICAL RODS GROUT REINFORCED CELLS SOLID HURRICANE CLIP - SIMPSON (2) H3 W/ 4-81) X 1 1/2 NAILS EACH TRUSS INSTALLED AT DIAGONAL BEARING POINTS UPLIFT 820# FRAMING DETAIL r___1 r-LI-I 0 E;# i/ PRE ENGINEERED WOOD TRUSS @ 24'O.C. CANTILEVERED OVERHANG - TRUSS DESIGN BY OTHERS FIBERGLASS BATT INSULATION R-30 H�RICANE CLIP - SIMPSON (2) H3 W/ 4-80 X 1 1/2 NAILS EACH TRUSS INSTALLED AT DIAGONAL BEARING POINTS - UPLIFT 820# 1/2' GYPSUM DRYWALL P.T.2XB J' ANCHOR BOLTS @ 24' O/C 8' KNOCK -OUT BLOCK REINF WITH 2 #5 CONTINUOUS ROO - POUR SOLID 8' U-BLOCK REINF WITH 1 #5 CONTINOUS ROD POUR SOLID PRECAST VENT BLOCK WITH SCREEN B'xlG' unit 81 CMU #5 VERTICAL HOOK DOWEL - SEE PLAN 4 2500 PSI CONCRETE SLAB 6X6 #10 WW MESH REINFORCING - OR FIBER L. L L L L. 6 MILL VISQUEEN VAPOR BARRIER L" b.",� 16 L" OVER CLEAN COMPACTED SAND FILL FOOTING 2500 PSI CONCRETE WITH (2) #5 ROOS CONTINUOUS REINFORCING V-4" WALL SECTION 3/4 1 0 61 ill L- — — — — — — — — — — — — — — — — — — — — — — — — — - WEST ELEVA'nON -EAST ELEVATION REVERSED is I -of$ 4/ 0 21 41 1/4 1 SEALAN* TYPICAL PEMKO 346C ALUMIN DOOR' RAIN DRIP 4� HEAD D ETAI L A-2 0) NTS GENERAL DOOR NOTES: 'AINTEO 8' CMU RECAST CONCRETE INTEL REINFORCED (/ 2 #5 CONTINUOUS ODS GROUT SOLID OIL Z.33 \4F A.F.F. ;EALANT 'YPICAL IOLLOW METALFRAME iROUT SOLID GENERAL DOOR NOTES: 1. ALL DOORS, FRAMES AND HARDWARE SHALL BE SOUND AND SECURE AND IN GOOD WORKING CONDITION, AOAQUET FOR TENANTS USE AND IN COMPLIANCE WITH FEDERAL AND FLORIDA ADA CODES. 2. NON -RATED INTERIOR SWING DOORS SHALL BE OPERABLE BY A FORCE OF NOT MORE THAN FIVE (5) POUNDS APPLIED TO THE LATCH STILE. 3. EXTERIOR SWING DOORS SHALL BE OPENED BY A FORCE OF OPERABLE BY A FORCE OF NOT MORE THAN EIGHT AND A HALF (8.5) POUNDS APPLIED TO THE LATCH STILE. 4. DOOR SIZE CONVENTION: 3070 3'-0' WIDE X 7'-U' HIGH DOOR & HARDWARE SCHEDULE: SEALANT TYPIC HOLLOW METAL GROUT SOLID SEALANT TYI PAINTED 8' JAMB A-2 OY NTS " FING 6* ALUMINUM FASCIA - - OIL' 10.9.0 TOP OF CMU WALL I" CMU HARDIE BOARD LAP SIDING 100.00 �-FASSUMED FINISH FLOOR 6R66f' CK-L-SID"LO' ERTICAL REINF D ETAI L 6� THRESHOLD D ETAI L A-2 OY NTS FOR DOOR _ULL BED 'MUM SLOPE WALK TAG LOCATION SIZE DOOR FRAME HARDWARE 101 A, 102A TOILET ROOM 3#-0" X 7'—o" NR 1 3/4" FLUSH FIBERGLASS 2"X5 1/5" FIBERGLASS KEYED ENTRY CYLINDER, ADA THRESHOLD, PUSH/PULL CLOSER, 1 1/2 PAIR BUTT HINGES, SILENCERS, WALL BUMPE 103A STORAGE ROOM 3'-0" X 7'-0" NR 1 3/4- FLUSH FIBERGLASS 2"X5 1/5" FIBERGLASS 1X PAIR OF BUTT HINGES, LEVER SET STORAGE FUNCTION, KEYED CYLINDER W/ THUMB TURN, WALL BUMPER 104A EXTERIOR STORAGE ROOM 39—Ops X 71-0" NR 1 3/4- FLUSH FIBERGLASS 2"X5 1/5" FIBERGLASS 1X PAIR OF BUTT HINGES, LEVER SET STORAGE FUNCTION, KEYED CYLINDER W/ THUMB TURN, THRESHOLD P; vl� 1�oijnrll to!,,- in cnrnpii�irncc with co&� �wd h,- 1" k/1 1�9 1513 5 FINISH NOTES: 1. PAINT INTERIOR WALLS COMPLETE WITH 1 HEAVY COAT BLOCK FILLER/PRIMER AND 2 COATS SHERWIN WILLIAMS LATEX EPDXY OR EQUAL PAINT WITH A COLOR TO BE SELECTED BY THE OWNER. 2. DOORS TO BE FLUSH HOLLOW METAL IN HOLLOW METAL FRAME. FACTORY PRIMED. FINISH WITH 2 COATS OF EXTERIOR LATEX. 3. INSTALL NEW 4' VINYL BASE ON ALL WALLS 4. FLOOR TO RECEIVE VCT TILE. COLOR TO BE SLECTEO BY OWNER. FLOOR PREP AND INSTALLATION TO BE PER MANUFACTURES RECOMENOATIONS. 5. cEILING TO BE 5/13' MOISTURE RESISTANT GYPSUM DRYWALL MOUNTED TO BOTTOM CORD OF TRUSS. LIGHT TEXTURE, p)RIME AND 1 FINISH COAT OF CEILING WHITE LATEX _< .< " LO 0 M CD 00 0 r--) E 0 rL LLJ U-) to 00 C'4 U-) im Ld L:: CD cn cn U-i PI) to Uj '" Lmn >- < rrj -< co cp cn M C�, C) NO-) L Ln R PO ry U) ::::, C) I C04 0 'n V) W—i Q -.0- C)" Ln Lo .d- 2 (::) ri co cr- 0 00 LL_ 0 o 0 Q) C-) 0 cn Ch- C14 4- Ul) rn c— P0 U I i 0 iE rNj co c— C) LCI V) C) I-_ < :�> c : L-Li PM 0 1 0 Of W-1 L_Lj _j of < CD re) 0 cli C) W �- Ox M0 Lj_J rr cL wo >< W ocn j W 19CO29 review 05-08-2019 approval permit 07-29-2019 revision revision A-201 4/ ELECTRICAL NO GENERAL NOTES: 1. ALL WORK SHALL BE IN ACCORDANCE WITH THE CODE DATA LIST AND SHALL ALSO COMPLY WITH ALL APPLICABLE RULES AND REGULATIONS OF LOCAL AND STATE LAWS AND ORDINANCES. 2. CONTRACTOR SHALL MAKE A THOROUGH EXAMINATION OF THE SITE AND THE CONTRACT DOCUMENTS. NO CLAIM FOR EXTRA COMPENSATION WILL BE RECOGNIZED IF DIFFICULTIES ARE ENCOUNTERED WHICH AN EXAMINATION OF SITE CONDITIONS AND CONTRACT DOCUMENTS PRIOR TO EXECUTING CONTRACT WOULD HAVE REVEALED. 3. ELECTRICAL CONTRACTOR SHALL ARRANGE FOR ALL NECESSARY PERMITS, LICENSES, UTILITY COORDINATION, AND INSPECTIONS AS REQUIRED BY THE CITY OR UTILITY COMPANY. CONTRACTOR IS RESPONSIBLE FOR ALL EQUIPMENT REQUIRED BY UTILITY COMPANY AND SHOULD INCLUDE NECESSARY COSTS IN BID. 4. CONTRACTOR SHALL LEGIBLY MARK-UP A SET OF 24'x36' DRAWINGS TO REFLECT AS -BUILT CONDITIONS, AND TURN OVER TO ARCHITECT. WIRE/RACEWAY: 1. ALL CONDUCTORS SHALL BE COPPER, CONDUCTOR INSULATION SHALL BE DUAL TYPE THHN/THWN 750C. (1670F) FOR DRY, DAMP, AND WET LOCATIONS. CONDUCTOR INSULATION WITH SINGLE TYPE MARKING THHN 900C (1940F) MAY BE USED FOR DRY LOCATIONS ONLY. ALL CONDUCTORS SHALL BE COLOR CODED AS REQUIRED BY NEC AND FURTHER IDENTIFIED AND CODED AS SPECIFIED HEREINAFTER. COLOR CODING SHALL BE BY MEANS OF COLORED INSULATING MATERIAL, COLORED 13RAIO OR JACKET OVER THE INSULATION OR BY MEANS OF SUITABLE COLORED, PERMANENT, NON -AGING, INSULATING TAPE APPLIED TO CONDUCTORS AT EACH CABINET OR JUNCTION POINT. THE COLOR COOING SHALL BE ACCOMPLISHED AS THE CONDUCTORS ARE INSTALLED. THE FOLLOWING SYSTEMS OF COLOR CODING SHALL BE STRICTLY ADHERED TO: A) GROUND LEADS: GREEN B) 120/208 VOLT UNGROUNDED PHASE WIRES: PHASE A: BLACK PHASE B: RED PHASE C: BLUE NEUTRAL: WHITE THE COLOR CODE ASSIGNED TO EACH PHASE WIRE SHALL BE CONSISTENTLY FOLLOWED THROUGHOUT. 2. UNLESS OTHERWISE INDICATED, ALL BRANCH CIRCUIT CONDUCTORS SHALL BE NO. 12 AWG. ANY BRANCH CIRCUIT RUN OVER 75 FEET IN LENGTH, MEASURING ONE WAY FROM THE FIRST OUTLET OF THE CIRCUIT TO THE PANEL, SHALL BE NO. 10 AWG. FOR THE ENTIRE CIRCUIT. 3. ALL INTERIOR BUILDING CONDUCTORS SHALL BE RUN IN THIN WALL CONDUIT AND THIN WALL CONDUIT SHALL BE UNDERWRITERS' APPROVED GALVANIZED ELECTRICAL METALLIC TUBING. COUPLINGS AND CONNECTORS SHALL BE STEEL SET -SCREW TYPE, ZINC OR CADMIUM PLATED. BELOW GRADE CONDUITS SHALL BE SCHEDULE 40 PVC WITH RIGID METAL ELBOWS AND RISERS. RIGID METAL CONDUIT BELOW GRADE OR IN CONCRETE SHALL BE COATED WITH BITUMASTIC OR SLEEVED WITH 10 MIL POLYETHYLENE. SITE CONDUITS SHALL BE ROUTED AT 24' BELOW GRADE AND CONDUITS ROUTED BELOW BUILDINGS SHALL BE AT 36'. EXTERIOR CONDUITS SHALL BE RIGID GALVANIZED STEEL. PENDING OWNER APPROVAL METAL CLAD CABLE (TYPE MC) IS ACCEPTABLE PROVIDED CABLE IS SUPPLIED WITH AN INSULATED GREEN EQUIPMENT GROUND CONDUCTOR AND MAY ONLY BE USED UNDER THE FOLLOWING CONDITIONS: A) SHORT RUNS IN WALLS. B) BETWEEN OUTLET BOXES IN HUNG OR FURRED CEILINGS, AND FLUSH TYPE LIGHTING FIXTURES AND TROUGH UNITS. C) CONNECTION TO EQUIPMENT IN SHELVING AND SHALL NOT BE USED FOR ANY CIRCUIT WITH OVER A 20 AMP CIRCUIT BREAKER. 0) HOME -RUNS OF MULTI -CONDUCTOR CABLE WILL BE ALLOWED. CABLING MUST BE PROPERLY SUPPORTED AND COMPLY WITH ALL NEC CODES. MAXIMUM OF 9 CIRCUITS OR 13 CONDUCTORS IN A HOME -RUN. E) SHALL BE APPROVED FOR BRANCH CIRCUIT WIRING (20 AMPS & UNDER ONLY) IN CEILING SPACES AND WITHIN WALLS. METAL CLAD CABLE IS NOT ACCEPTABLE UNDER THE FOLLOWING CONDITIONS: A) BRANCH CIRCUITS OVER 20 AMPS. 8) WHERE CABLING WILL BE EMBEDDED IN CONCRETE. C) WHERE CABLING WILL BE EXPOSED TO MOISTURE. 0) WHERE PROHIBITED BY LOCAL CODE. 4. COMBINING OF CIRCUITS IN SAME RACEWAY, OTHER THAN THOSE INDICATED ON DRAWINGS, WILL NOT BE PERMITTED. 5. ALL RACEWAYS SHALL BE PROPERLY ALIGNED, GROUPED, AND SUPPORTED BY MECHANICAL TYPE 'CADDY' CLIPS AT INTERVALS NOT EXCEEDING 8 FEET. G. ALL RACEWAYS WITH NO. 10 OR 12 AWG PHASE CONDUCTORS FOR RECEPTACLES, LIGHTING FIXTURES AND SIMILAR CIRCUITS SHALL BE PROVIDED WITH A PARITY SIZED GREEN EQUIPMENT GROUND CONDUCTOR. GROUND CONDUCTOR SHALL BE INSTALLED IN ENTIRE RACEWAY SYSTEM INCLUDING WALL SWITCHES AND FLEXIBLE CONDUIT TO LIGHT FIXTURES. EQUIPMENT GROUND CONDUCTOR SIZES FOR CIRCUITS WITH PHASE CONDUCTORS LARGER THAN NO. 12 AWG ARE INDICATED ON DRAWINGS. GROUND CONDUCTORS SHALL BE CONNECTED TO GROUND BUSS IN PANELBOARDS. 7. RACEWAY PENETRATIONS OF FIRE RATED WALLS AND/OR FLOORS SHALL BE SEALED TO MAINTAIN INTEGRITY OF CONSTRUCTION. ALL PRODUCTS, MATERIALS AND METHODS OF INSTALLATION SHALL BE UL APPROVED AND MEET NFPA. GROUNDING: 1. THE ENTIRE ELECTRICAL SYSTEM SHALL BE COMPLETELY AND EFFECTIVELY GROUNDED AS REQUIRED BY NATIONAL ELECTRICAL CODE. ALL METALLIC RACEWAYS SHALL BE MECHANICALLY AND ELECTRICALLY SECURE AT ALL JOINTS AND AT ALL BOXES, CABINETS, FITTINGS AND EQUIPMENT. 2. THE GROUNDING SYSTEM SHALL BE TESTED BY THE CONTRACTOR. THE RESISTANCE TO GROUND SHALL BE NO MORE THAN FIVE (5) OHMS. SUBMIT TEST RESULTS TO ENGINEER. CONTRACTOR SHALL MAKE UPGRADES AND ADDITIONS TO GROUNDING SYSTEM AS REQUIRED TO ACHIEVE THE (5) OHM REQUIREMENT. 3. PROVIDE NO. 6 AWG GROUND CONDUCTOR AT TELEPHONE BOARD AND CONNECTION TO THE MAIN SERVICE ENTRANCE GROUND. PROVIDE 1OFT. OF SLACK AT BOARD. OUTLET BOXES/DEVICES: 1. COORDINATE DEVICE AND COVER PLATE COLORS WITH ARCHITECT. 2. ALL OUTLET BOXES SHALL BE RIGIDLY MOUNTED AND SHALL BE EQUIPPED WITH SUITABLE SCREW FASTENED COVERS. OPEN KNOCKOUTS OR HOLES IN BOXES SHALL BE PLUGGED WITH SUITABLE BLANKING DEVICE. 3. OUTLET BOXES SHALL BE 4 INCH OCTAGONAL x 2-1/8' DEEP. OUTLET BOXES LOCATED ABOVE THE CEILING SHALL BE LEGIBLY IDENTIFIED WITH BRANCH CIRCUIT NUMBER OF CIRCUIT TERMINATED WITHIN BY MEANS OF BLACK PERMANENT MARKER. 4. NEC 210.12(A) ALL 120 VOLT, SINGLE PHASE, 1S & 20 AMPERE BRANCH CIRCUITS SUPPLYING OUTLETS OR DEVICES INSTALLED IN DWELLING UNIT KITCHENS, FAMILY ROOMS ' DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, LAUNDRY AREAS OR SIMILAR ROOMS OR AREAS SHALL BE PROTECTED BY ARC -FAULT CIRCUIT INTERRUPTER. 5. NEC 406.12 ALL 15 & 20 AMPERE, 125 & 250 VOLT NON -LOCKING -TYPE RECEPTACLES IN DWELLING UNITS SHALL BE TAMPER- RESI S TANT RECEPTACLES. 6. NEC 210.8 ALL 125 VOLT, 15 & 20 AMPERE RECEPTACLES INSTALLED IN BATHROOMS, GARAGES, AND ALSO ACCESSORY BUILDINGS THAT HAVE A FLOOR LOCATED AT OR BELOW GRADE LEVEL NOT INTENDED AS HABITABLE ROOMS AND LIMITED TO STORAGE AREAS, WORK AREAS, AND AREAS OF SIMILAR USE, OUTDOORS, CRAW SPACES, UNFINISHED PORTIONS OR AREA OF THE BASEMENT NOT INTENDED AS HABITABLE ROOMS, KITCHENS WHERE THE RECEPTACLES ARE INSTALLED TO SERVE THE COUNTERTOP SURFACES, SINKS WHERE RECPTACLES ARE INSTALLED WITH IN 6 FEET FROM THE TOP INSIDE EDGE OF THE SINK BOWL OF THE SINK, BOATHOUSE, BATHTUBS OR SHOWER STALL WHERE RECEPTACLES ARE INSTALLED WITHIN 6 FEET OF THE OUTSIDE EDGE OF THE BATHTUB OR SHOWER STALL, & LAUNDRY AREAS. SWITCHGEAR: 1. PANELBOARDS SHALL BE MANUFACTURED BY SQUARE 'D' COMPANY, TYPE AS SHOWN ON DRAWINGS OR APPROVED EQUAL. FURNISH WITH COPPER BUS BARS, COPPER EQUIPMENT GROUND BUS AND BOLT -ON CIRCUIT BREAKERS. 2. DISCONNECT SWITCHES SHALL BE HEAVY-DUTY TYPE AND MANUFACTURED BY SQUARE 'D' COMPANY OR APPROVED EQUAL. FUSES SHALL BE DUAL ELEMENT, CARTRIDGE TYPE. FUSES SHALL BE BY ONE MANUFACTURER: BUSSMAN 'FUSETRON' OR CHASE-SHAWMUT 'TRIONIC. 3. INSTALL ENGRAVED PLASTIC -LAMINATE LABELS ON EACH MAJOR UNIT OF ELECTRICAL EQUIPMENT IDENTIFYING PANELBOARD NAME OR EQUIPMENT SERVING. EXAMPLES ARE, PANELBOPRGS, OISCONNECT SWITCHES, AND MOTOR STARTERS, I.E. LABELS SHALL BE 1/16' THICK BEA�-K PLASTIC LAMINATE WITH 3/8' WHITE CORE PLIE LETTERS. 4. PANELBOARD DIRECTORY CARDS SHALL BE TYPEWRITTEN WITH ACCURATE AND CURRENT INFORMATION BY THE CONTRACTOR AT THE END OF CONSTRUCTION. 5. ALL MULTI -WIRE BRANCH CIRCUIT C IRCUI T -BREAKERS ARE TO BE TIED TOGETHER BY AN IDENTIFIED HANDLE -TIE OR BY A COMMON TRIP CIRCUIT BREAKER PER NEC SECTION 210.4(B). LIGHTING FIXTURES: 1. THE CONTRACTOR SHALL FURNISH AND INSTALL COMPLETE IN ALL RESPECTS ALL LIGHTING FIXTURES LISTED IN THE FIXTURE SCHEDULE. 2. THE CONTRACTOR SHALL SUBMIT CATALOG CUTS OF ALL THE FIXTURES TO THE ARCHITECT. THESE CUTS SHALL BE SUBMITTED IMMEDIATELY AFTER THE CONTRACTOR HAS RECEIVED AN APPROVED MATERIAL LIST FROM THE ARCHITECT. 3. BALLASTS FOR FLUORESCENT LAMPS SHALL BE ELECTRONIC RAPID START WITH <10% TOTAL HARMONIC DISTORTION MANUFACTURED BY 'OSRAM SYLVANIA. ALL BALLASTS FOR FLUORESCENT FIXTURES SHALL BE INDIVIDUALLY FUSED. FUSES SHALL BE INSTALLED ON THE LINE SIDE OF THE BALLAST. 4. FLUORESCENT LAMPS SHALL BE RAPID START, TB/32 WATT, 3500K. ALL LAMPS SHALL BE AS MANUFACTURED BY SYLVANIA. 5. ALL FIXTURES SHALL BE PROPERLY AND CAREFULLY SUPPORTED AND ALIGNED, AND THE CONTRACTOR SHALL FURNISH AND INSTALL ALL NECESSARY STEEL SHAPES, ETC., FOR SUPPORT OF FIXTURES AS REQUIRED AND DETAILED ON THE DRAWINGS. PROVIDE JUNCTION BOX STEM MOUNTED FROM DECK TO SUPPORT ALL CEILING MOUNTED EXIT LIGHTS. 6. LIGHTING FIXTURES SHALL BE CLEAN AND LAMPED WITH NEW LAMPS AT THE TIME OF FINAL INSPECTION. 7. COORDINATE ALL LOCATIONS OF LIGHTING FIXTURES WITH ARCHITECTURAL DRAWINGS. B. ALL FLUORESCENT FIXTURES SHALL HAVE A DISCONNECTING MEANS EITHER INTERNAL OR EXTERNAL IN ACCORDANCE WITH NEC ARTICLE 410.73(G). OCCUPANCY SENSORS: 1. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS SHOWING LOCATIONS OF ALL UNITS AND CUT SHEETS FOR ALL DEVICES. LIGHTING & SMOKE NOTES: 1. FLORIDA BUILDING CODE 907.2.11.2 & 908.7.2 INSTALL ON THE CEILING OR WALL INSIDE OR DIRECTLY OUTSIDE OF EACH ROOM USED FOR SLEEPING PURPOSES. 2. FLORIDA BUILDING CODE 907.2.11.4 POWER SOURCE IN NEW CONSTRUCTION REQUIRED SMOKE ALARM ALARM SHALL RECEIVE THEIR PRIMARY POWER FROM THE BUILDING WIRING WHERE SUCH WIRING IS SERVED FROM A COMMERCIAL SOURCE AND SHALL BE EQUIPPED WITH A BATTERY BACKUP. 3. WHERE MORE THAN ONE SMOKE ALARM IS REQUIRED TO BE INSTALLED SHALL BE INTERCONNECTED IN SUCH A MANNER THAT THE ACTIVATION OF ONE WILL ACTIVATE ALL OF THE ALARMS IN THE INDIVIDUAL UNIT. 4. NEC 210.12(A) ALL LIGHT SWITCH FEEDING AN OUTSIDE SHALL BE ARC FAULT BREAKER. SINGLE -LINE DIAGRAM KEY NOTES 1. MAXIMUM SYMMETRICAL RMS FAULT CURRENT. ALL PANELBOAROS AND BREAKERS SHALL BE CAPABLE OF WITHSTANDING THE MOMENTARY FAULT CURRENT LEVEL SHOWN. 2. UTILITY APPROVED METER WITH 50A/1P BREAKER. A HEAVY-DUTY JAW RELEASE METER ENCLOSURE WITH LEVER TYPE BY-PASS SHALL BE INSTALLED. POINT OF ATTACHMENT 3 #4 CU 1 #8 CU EG 1 1/2' C F_ 12' X 12' X 6 PVC J-BOX WITH GASKET COVER NEW SURGE 50 A PANEL 8 PROTECTIVE DEVICE �PO 120/208 ATLANTIC I PHASE SCIENTIFIC TYPE 3R #161-208V 4 SER EXISTING DECK EXISTING OVERHEAD FEED 1-0 Lz_0 3 #4 CU NEW EXISTING EXISTING 1 #8 CU EG 50 A A/C 100 A DISCONNECT 1 1/ 2' C METER METER # 8CU CONNECTED TO SUPPLEMENTAL ELECTRODS PER NEC 250.53 3/4' x 10'-0" COPPER CLAD GROUND ROD. PLACE A MINIMUM OF 10'-D' APART IN RECESSED CONCRETE TEST WELL WITH STEEL COVER PLATE. GROUNDING SYSTEM MUST BE TESTED AND BE 5 OHMS OR LESS. NO.3/0 CU CONNECTED TO SUPPLEMENTAL ELECTRODES PER NEC 250.53. BONDING OF COMMUNICATION SHALL MEET TO NEC 250.94(A) 1-6 OF INTERSYSTEM BONDING. NEW PANEL A LOCATED IN CUSTODIAL CLOSET U NEW �OILET ROOM BUILDING I 1 1/2' C BELOW EXISTING PARKING GRADE PUL BOX 1 1/2' J IN ATTIC/ EXISTING RESTAURANT BUILDING EXISTING NEW 100 A 50 A METER METER EXISTING 100 A PANEL EXISTING EXISTING A/C FENCE I UNITS PARTIAL SITE PLAN 90 I -off 1/16 1 EXISTING 100 A PANEL SINGLE -LINE DIAGRAM NTS NORTH GFI 36' AFF COORDINATE HEIGF WITH HAND ORYE REQUIREMENTS i L in 'd jB-3 1�. - UITCH TO INTROL OONWLIGHT Lj DO Li 0C S 1312 ILISWIT H T SWITCH TO CONTR L IAREA CONTROL AREA FIXT ES Eo FIXTURES Cls LA 0S _T LIGHTING P LAN I -off 4/ 0 1 /4 GFI all 0�4 B_ IDCC SENSOR TO CONTROL 1EIGHTINGFAt4E XHAUST FAN GF q"11:4ra o PANEL 8 0 0 0 A- 3BCj C GFI 13­7 OCC SENSOR TO CONTROL LIGHTING ANO EXHAUST FAM ELECTRICAL PLAN NOTE 1. CONTRACTOR TO PROVIDE ALL WIRING, CONDUIT, MATERIALS, EQUIPMENT, ETC., SHOWN OR REQUIRED TO COMPLETE THE ELECTRICAL WORK UNLESS OTHERWISE SPECIFIED. ANY ITEM OR SYSTEM WHICH IS SHOWN, MENTIONED OR REASONABLY IMPLIED ON EITHER DRAWINGS OR IN THE SPECIFICATIONS SHALL BE CONSIDERED TO BE PROPERLY AND SUFFICIENTLY SPECIFIED ANO SHOWN, AND MUST BE PROVIDED. INCLUDE ALL LABOR, EQUIPMENT, TOOLS, ETC., REQUIRED TO COMPLETE ALL INSTALLATIONS AS INTENDED. INSTALL ALL EQUIPMENT ACCORDING TO THE METHOD INDICATED, MANUFACTURERS INSTRUCTIONS OR ACCORDING TO STANDARD INDUSTRY PRACTICES IF NO INSTALLATION TECHNIQUE IS DEFINED. 2. CONTRACTOR TO PROVIDE ALL WORK AND MATERIALS IN ACCORDANCE WITH THE LATEST EDITIONS OF THE NATIONAL ELECTRICAL CODE (N.E.C.), THE FLORIDA BUILDING CODE, APPLICABLE NFPA AND UL STANDARDS, AND ALL OTHER APPLICABLE FEDERAL, STATE AND LOCAL CODES AND REGULATIONS. ANY MATERIALS, EQUIPMENT OR INSTALLATIONS NOT MEETING ALL REQUIREMENTS OF THE APPROPRIATE REGULATORY AGENCIES WILL NOT BE ACCEPTED. IT IS THE CONTRACTOR'S RESPONSIBILITY TO ENSURE THE REQUIREMENTS ARE MET AND PROVIDE EVIDENCE OF SUCH IF REQUESTED. 3. PER FLORIDA BUILDING CODE 2017, TABLE C405.2(2). THE ALLOWED LIGHTING LOAD FOR RESTROOMS IS LPD = .98. THE ALLOWABLE LOAD IS 329 WATTS. THE ACTUAL LOAD FOR THIS SPACE IS 143 WATTS WHICH COMPLIES. 4. PER FBC ENERGY CONSERVATION SECTION C405.2 PROVIDE MANUAL AND AUTOMATIC CONTROLS IN ALL SPACES. 5. PER FBC ENERGY CONSERVATION 408.3 A FUNCTIONAL TEST OF THE LIGHTING CONTROLS SYSTEMS WILL BE PERFORMED. THE LIGHTING CONTROL SYSTEM TO BE TESTED TO ENSURE THAT CONTROL HARDWARE AND SOFTWARE ARE CALIBRATED, ADJUSTED, PROGRAMED AND IN PROPER WORKING CONDITION IN ACCORDANCE WITH THESE DOCUMENTS AND MANUFACTURES INSTRUCTIONS. G. DRAWINGS AMO OPERATION AND MAINTENANCE MANUALS TO 13E PROVIDED TO THE OWNER PER FBO ENERGY CONSERVATION SECTION C405.6.4. CLEARLY IDENTIFY ROUTINE MAINTENANCE REQUIREMENTS. PROVIDE THE NAME, ADDRESS AND PHONE NUMBER FOR A QUALIFIED SERVICE AGENCY. 7. ELECTRICAL PANEL LAK1.1.139.OR.P2 IS EXISTING 1201208 3 PHASE 4 WIRE 200 AMP 42 CIRCUIT PANEL. AIC 10,000. PANEL IS LOCATED IN THE PANEL ROOM - SEE DIAGRAM AT THE LEFT. NO NEW PANELS ARE TO BE PROVIDED. LIGHTING CIRCUITS ARE EXISTING. EXISTING 20 AMP BREAKERS AT CIRCUIT 31, 32, 33, 34 ARE DESIGNATED FOR PROJECT'S NEW POWER RECEPTACLES. B. NOTE NOT USED 9. ALL EXIT LIGHTS TO BE CONNECTED TO LIGHTING CIRCUIT FOR THAT AREA. 10. ALL EXIT AND EMERGENCY LIGHTS OVER EXISTING EXTERIOR DOORS. ALL EXIT AND EMERGENCY LIGHTS OVER EXISTING EXTERIOR DOORS AND AT CORRIDORS ARE EXISTING AND SHALL REMAIN IN PLACE. 11. NOTE NOT USED 12. GENERAL CONTRACTOR SHALL INSURE/VERIFY THAT LOCATIONS INDICATED FOR ELECTRICAL CORRESPOND WITH STANDARD FIXTURES AS INDICATED ON ELEVATION, PLAN & DETAIL SHEET(S). ANY DISCREPANCIES SHALL BE REPORTED TO THE OWNER PRIOR TO INSTALLATION OF FIXTURES AND ELECTRICAL EQUIPMENT. DISCREPANCIES REPORTED FOLLOWING INSTALLATION ARE THE SOLE RESPONSABILITY OF THE GENERAL CONTRACTOR. 13. NOTE NOT USED 14. NOTE NOT USED 15. WHEN THE ELECTRICAL PANEL IS EXPOSED TO THE FLOOR/PUBLIC, THE ELECTRICAL PANEL SHALL BE ENCLOSED IN A CLOSET WITH ACCESS DOOR MEETING ALL NEC CODES AND ANSI/AOAAG CODES AROUND THE CLOSET. 16. ALL FIXTURES ARE PROVIDED BY THE OWNER AND INSTALLED BY THE GENERAL CONTRACTOR. 17. ADD APPROXIMATELY (4) NEW 1X4 LEO 35W LIGHT FIXTURES AND I 15W RECESSED CAN DOWNLIGHT. FIELD VERIFY EXACT FIXTURE NUMBER. le. FOR ADDITIONAL INFORMATION ON EQUIPMENT SPECIFICATIONS, SEE SPEC SHEETS. GFI 36' AFF GF1 COORDINATE HEIGHT WITH HAND DRYER REQUIREMENTS fow ot POWER PLAN 1/4 of 1 4/ 0 21 41 PANEL SCHEDULE PANEL AND BREAKERS WILL TIE TO EXISTING. PANEL B AMPS: 50 VOLTAGE: 120/208 PHASE: SINGLE TYPE: 3R AIC:10,000 LOCATION: OUTDOOR RATED - CUSTODIAL CLOSET OF NEW BLD'G nTc;rPTPTTnN RR rTR CTR RR DISCRTPTION MEN GFI 20 1 2 20 WOMEN GFI MEN FART FAN 1 20 3 4 20 WOMEN FART FAN I MEN FAN 2 20/2 1 5 6 20/2 WOMEN FAN 2 1 7 1 8 MEN MAINT GFI 20 9 10 20 WOMEN MAINT GFI JAN GFI 20 11 12 20 SIGNAGE LEG�ND j 1 X 4 32W SURFACE MOUNTED LED LIGHTING FIXTURE SINGLE POLE SWITCH W/ OCCUPANCY SENSOR CONTROL 110S 0 DAYLIGHT HARVESTING CONTROLLER CEILING MOUNTED CIRCUIT RUN CONCEALED UNDER FLOOR OR BENEATH GRADE HOMERUN TO PANEL, LETTERS INDICATE PANEL, NUMBERS INCIOCATE CIRCUIT. ANY CIRCUIT WITHOUT FURTHER DESIGNATION INDICATES A 2-WIRE & EQUIPMENT GROUND. EXIT SIGN - NEW BEGHLLI VA4-5-HT SURFACE MOUNT UNV LEO RED BACK LIT LETTERS ON WHITE BACKGROUND EMERGENCY LIGHTS - NEW BEGHELLI XMR-650 SURFACE MOUNT UNV 2W 2 HEAD LED EMERGENCY LIGHT WITH BATTERY BACK-UP @GFI 2-OUTLET GFI RECEPTACLE: Standard 120V GFI OupLex ELectricaL ReceptacLe mounted at 6' above counter with white pLastic cover unLess otherwise noted. EF 1 - EXHAUST FAN PANASONIC FV-40VQ4 380 380 CFM 3 SONES 17"X15" X9"D Ic><01 EF 2 - WALL MOUNTED VENTAMATIC LTD IF14 EXHAUST FAN 1400 CFM, 14", 120V, 17" X 17" ROUGH OPENING FLOOR DRAIN OVERHEAD DUCTING & EXHAUST GRILL WITH WEATHERHEAD 0 -0 0 0- 0 -+_ U 1�0 MA N" ry t:� C= 0 Cn L&_j ry C)e 0 (0 L0 C:) 00 P0 E re) 0 i 1� LL_ :S CL > ED ��e :S 0 .0 U-) > (0 CN7 00 U-) C14 NO W t-) L: C� Z:) r- Lri U') C-4 rrj CD V) CR C:) C:) rn C) C) co C14 C-) V) U-) < Id: M C) U-3 V) "d: C:> ff -> C) to I 00 LL_ 00 Ln L1=5 > -< rn L__ r-, cf� cn ro 0 (-) ID o _.., En 0 LL_ (z) C_ LLJ C) zt:� 00 E 0 -r- C"i 00 Q) --C) Cf) 0 C14 .d- LO r1r) C_ U iE Q) C- NO C) LO cl- 1 0 C*4 ir 0 M W R 0- MO R 0 000 5; 3 Uj 19CO29 review 06-13-2019 approval permit 07-29-2019 revision revision E-101 PLUMBING NOTE GENERAL: 1. THE INTENT IS TO INSTALL NEW PLUMBING FIXTURES. PRIOR TO PURCHASING, FIELD VERIFY THAT ALL SPECIFIED FIXTURES CAN BE INSTALLED TO SPECIFIED LOCATIDNS. 2. REFER TO FIXTURE SCHEDULE FOR L-1 LAVATORY: PROVIDE SINGLE MULTI -UNIT POWER ADAPTER TO SERVE ALL AUTOMATIC FAUCETS AND FLUSH VALVES FOR EACH SEPARATE TOILET ROOM. INSTALL BELOW LAVATORY COUNTERTOP. LOW VOLTAGE WIRING TO URINALS AND WATER CLOSETS SHALL BE IN CONDUIT (CONDUIT INSTALLED BY ELECTRICAL TRADE). 3. RECONNECT ALL TRAP PRIMERS TO WATER SOURCE. EXTEND PIPING WHERE REQUIRED. 4. ALL WORK SHALL COMPLY WITH APPLICABLE NATIONAL, STATE, AND LOCAL CODES. THIS SHALL INCLUDE, 13UT NOT BE LIMITED TO, THE 2016 FLORIDA PLUM13ING CODE, 6TH EDITION. 5. REVIEW PLANS OF ALL TRADES PRIOR TO BIDDING AND INSTALLATION TO INCLUDE ALL PLUMBING FOR COMPLETE SYSTEMS SHOWN ON THE PLANS AND AS REQUIRED. 6. COORDINATE WITH OTHER TRADES TO PREVENT INTERFERENCE WITH HVAC DUCTS, STRUCTURE, ELECTRICAL LIGHTING AND OTHER PIPING IN THE CEILING SPACE. VENT PIPING AND WATER PIPING SHALL BE HELD EITHER ABOVE OR BELOW HVAC OUCTWORK AS COORDINATED WITH THE HVAC CONTRACTOR. 7. ALL CHANGES SHALL BE REVIEWED BY THE ARCHITECT. B. COORDINATE WITH ARCHITECTURAL DRAWINGS BEFORE ROUGHING -IN PLUMBING FIXTURES AND EQUIPMENT SUPPLIES. 9. THE PLUMBING SUBCONTRACTOR SHALL FURNISH AND INSTALL ALL PLUMBING FIXTURES, UNLESS NOTED OTHERWISE. 10. VERIFY MOUNTING HEIGHT AND WATER CONNECTION SIZES TO ALL PLUMBING FIXTURES PRIOR TO ROUGH -IN. FURNISH CUTOUT TEMPLATES FOR PLUMBING FIXTURES TO BE INSTALLED IN MILLWORK, TO THE GENERAL EQUIPMENT. 11. MAKE PROPER COLO WATER, WASTE AND VENT PIPING CONNECTIONS TO ALL FIXTURES AND EQUIPMENT EVEN THOUGH ALL FITTINGS AND CONNECTIONS ARE NOT SHOWN. 12. VERIFY LOCATION OF EXISTING WATER SERVICE AND THE LOCATION/INVERTS OF SANITARY PIPING PRIOR TO INSTALLATION. 13. IT IS THE INTENT OF THESE DRAWINGS TO COVER ALL WORK AND MATERIAL. ANY EQUIPMENT, PLUMBING FIXTURES, TRIM HARDWARE, AND/OR DEVICES USUALLY UTILIZED IN THE CLASS OF WORK, THOUGH NOT SPECIFICALLY MENTIONED OR SHOWN ON THESE DRAWINGS, BUT WHICH MAY BE NECESSARY FOR THE SATISFACTORY COMPLETION OF THE WORK (AS DETERMINED BY THE ARCHITECT) SHALL BE FURNISHED AND INSTALLED BY THE CONTRACTOR AS PART OF HIS TOTAL WORK. 14. THE EQUIPMENT ROUGH -IN ITEMS AND THEIR DIMENSIONED LOCATIONS FOR ALL CONNECTIONS ARE ACCURATE TO THE BEST OF OUR KNOWLEDGE. IN SOME INSTANCES THE OWNER OR SUPPLIER MAY MAKE SUBSTITUTIONS OR THE EQUIPMENT ITEMS MAY VARY FROM WHAT IS SHOWN. THEREFORE, THESE ITEMS AND DIMENSIONS SHALL BE VERIFIED WITH THE EQUIPMENT SUPPLIER, OWNER ANO/OR EQUIPMENT ROUGH -IN DRAWING. FAILURE OF THE APPROPRIATE CONTRACTOR TO VERIFY ROUGH -INS OR THEIR LOCATIONS SHALL PLACE THE RESPONSIBILITY FOR ANY SUBSEQUENT RELOCATION AND/OR ADDITIONAL ROUGH -INS DIRECTLY UPON THE CONTRACTOR. 15. CONTRACTOR SHALL SUPPLY TO THE ARCHITECr THE REQUIRED COPIES OF SHOP DRAWINGS FOR APPROVAL SO THE QUALITY OF INTENDED MAT71RIALS OR EQUIPMENT CAN BE REVIEWED BEFORE INSTALLATION. THERE WILL BE �d DRAW UNTIL SHOP DRAWINGS HAVE BEEN SUBMITTED AND REVIEWED BY THE ARCHITECT/ENGINEER. 16. DO NOT SCALE THIS DRAWING. REFER TO ARCHITECTURAL FLOOR PLAN FOR BUILDING DIMENSIONS. 17. THESE DRAWINGS ARE DIAGRAMMATIC IN NATURE AND DO NOT NECESSARILY SHOW ALL ELBOWS, OFFSETS, UNIONS, VALVES, AND FITTINGS REQUIRED TO COMPLETE THE INSTALLATION OF THE WORK. THE SUBMISSION OF A PROPOSAL SHALL BE CONSTRUED AS EVIDENCE THAT THE CONTRACTOR HAS FAMILIARIZED HIMSELF WITH THE PLANS AND BUILDING SITE. CLAIMS MADE SUBSEQUENT TO THE PROPOSAL FOR MATERIALS AND LABOR BECAUSE OF DIFFICULTIES ENCOUNTERED WILL NOT BE RECOGNIZED. 18. THE CONTRACTOR SHALL COOPERATE FULLY AMONG THE TRADES. 19. THE WATER PIPING SYSTEM SHALL BE FLUSHED AND STERILIZED IN ACCORDANCE WITH LOCAL REGULATIONS. 20. DOMESTIC WATER SUPPLY BRANCHES FOR ALL EQUIPMENT HAVING QUICK CLOSING VALVES OF ANY TYPE SHALL HAVE WATER HAMMER ARRESTOR INSTALLED AT THE HIGH POINT ON THE END OF EACH BRANCH. 21. FURNISH AND INSTALL SHUTOFF OR BALL VALVE AND DIELECTRIC UNIONS ON ALL EQUIPMENT DOMESTIC WATER LINES. PLUMBING CONTRACTOR SHALL MAKE ALL FINAL CONNECTIONS TO EQUIPMENT. COORDINATE WITH EQUIPMENT SUPPLIER FOR EXACT REQUIREMENTS. 22. PROVIDE CHROME PLATED ESCUTCHEONS AT ALL WALL PENETRATIONS. 23. MATERIALS, EQUIPMENT, ASSEMBLIES AND SYSTEMS SHALL MEET ALL PERTINENT REQUIREMENTS OF NATIONALLY RECOGNIZED TESTING ORGANIZATIONS SUCH AS UL, ASTM, ASSE, AWWE, AGA, AND NFPA AS WELL AS THE MOST CURRENT VERSION OF THE STATE AND LOCAL CODES. 24. ALL INSTALLED SYSTEMS, DEVICES, AND RELATED ITEMS SHALL BE TESTED IN PLACE. REPLACE ANY AND ALL CONTRACTOR SUPPLIED DEFECTIVE DEVICES, ITEMS OR SYSTEMS AT CONTRACTOR'S OWN EXPENSE BEFORE COMPLETION OF PROJECT. 25. WHERE JOB CONDITIONS REQUIRE CHANGES FROM THE CONTRACT DOCUMENTS THAT DO NOT CHANGE THE SCOPE OR NATURE OF WORK REQUIRED, THE CONTRACTOR SHALL MAKE SUCH CHANGES WITHOUT ADDITIONAL COST TO THE OWNER. NO OTHER CHANGES MAY BE MADE WITHOUT WRITTEN PERMISSION OF THE ENGINEER. 26. ALL EQUIPMENT, FIXTURES, AND MATERIALS SHALL BE NEW AND UNUSED, AND INSTALLED IN STRICT CONFORMANCE TO MANUFACTURER'S RECOMMENDATIONS (U.O.N.). PROVIDE COMPLETE WITH ALL TRIM, STOPS, HANGERS, CARRIERS, SUPPORTS, ETC. INCLUDING PROVISIONS FOR BARRIER FREE USE, IF REQUIRED. WHERE FIXTURES ARE ACCESSIBLE THEY MUST COMPLY WITH ALL FEDERAL A.D.A. REGULATIONS AND STATE OF FLORIDA ACCESSIBILITY CODE. 27. CONTRACTOR SHALL GUARANTEE ALL WORK FOR WHICH MATERIALS ARE FURNISHED, FABRICATED OR FIELD ERECTED, ALL FACTORY ASSEMBLED EQUIPMENT FOR WHICH NO SPECIFIC MANUFACTURER'S GUARANTEE IS FURNISHED, AND ALL WORK IN CONNECTION WITH THE INSTALLATION OF MANUFACTURER'S GUARANTEED EQUIPMENT. THE CONTRACTOR'S GUARANTEE SHALL LAST ONE YEAR FROM THE FINAL OWNER ACCEPTANCE OF THE WORK AND SHALL APPLY TO ALL DEFECTS IN MATERIALS AND WORKMANSHIP OF ANY KIND. 28. PLUG OR CAP PIPE AND FITTINGS TO KEEP OUT DEBRIS DURING CONSTRUCTION. 29. TURNS SHALL BE MADE WITH 2-6 BENDS WHERE SPACE PERMITS, ELSEWHERE WITH Y FITTINGS AND 6 BENDS. 30. GENERAL CONTRACTOR SHALL INSURE/VERIFY THAT LOCATIONS INDICATED FOR PLUMBING CORRESPOND WITH STANDARD FIXTURES AS INDICATED ON ELEVATION, PLAN & DETAIL SHEET(S). ANY DISCREPANCIES SHALL BE REPORTED TO THE OWNER PRIOR TO INSTALLATION OF FIXTURES, UTILITIES AND PLUMBING EQUIPMENT. DISCREPANCIES REPORTED FOLLOWING INSTALLATION ARE THE SOLE RESPONSABILITY OF THE GENERAL CONTRACTOR. PLUMBING FIXTURES: 1. INSTALL ALL PIPING AND FITTINGS FOR PLUMBING FIXTURES AS SHOWN ON THE DRAWINGS AND AS HEREINAFTER SPECIFIED, MAKING ALL CONNECTIONS THERETO. THE PLUMBING TRADE SHALL REVIEW THE ARCHITECTURAL DRAWINGS AND INCLUDE IN HIS BID AN AMOUNT TO FURNISH ANY FIXTURES SHOWN IN ADDITION TO THE FIXTURES SHOWN ON THE PLUMBING DRAWINGS. 2. ALL ROUGHING -IN SHALL BE ACCURATELY LAID OUT, AND NO OFFSETS WILL BE ACCEPTED. 3. PROVIDE CHROME PLATED RIGID OR FLEXIBLE SUPPLIES WITH STOPS, REDUCERS AND ESCUTCHEONS TO FIXTURES. 4. WHERE FUTURE FIXTURES ARE SHOWN ON DRAWINGS TO BE ROUGHEO-IN, PLUG OR CAP OUTLET BRANCHES FOR SAME, GAS TIGHT AND WATER TIGHT. CAP OPENINGS IN WALLS WITH STAINLESS STEEL COVER PLATES, SECURED WITH KNOCK -OFF HEAD SCREWS 5. ACCESSIABLE TOILETS TO HAVE FLUSH LEVER ON OPEN SIDE OF TOILET STALL. WATER PIPING AND FITTINGS: 1. PROVIDE ALL WASHROOM GROUPS AND BRANCH TAKE -OFFS FROM MAINS WITH ISOLATING GATE VALVES. INSTALL STOP VALVE IN EACH FIXTURE SUPPLY. 2. ABOVE GROUND WATER SERVICE SHALL BE PEX ASTM F B77, SOR 9 TUBING 3. FITTINGS FOR PEX TUBE; ASTM F 1807, METAL -INSERT TYPE WITH COPPER OR STAINLESS STEEL CRIMP RINGS WITH MATCHING PEX TUBE DIMENSIONS 4. MANIFOLD: MULTIPLE -OUTLET, PLASTIC OR CORROSIVE RESISTANT METAL ASSEMBLY COMPLYING WITH ASTM F 877j WITH PLASTIC OR CORROSION -RESISTANT METAL VALVE FOR EACH OUTLET. 5. ALL HOT WATER PIPING SHALL BE INSULATED WITH 1' THICK JOHNS MANVILLE MICRO-LOK PIPE INSULATION, COMPLETE WITH VAPOR RETARDING JACKET AND LAP SEALING SYSTEM. SANITARY DRAINS AND FITTINGS: 1. ALL SANITARY DRAINS SHALL BE TYPE OWV-PVC AS PERMITTED BY CODE. SUPPORTS: 1. 2' NOMINAL AND UNDER, USE GRINNELL NO. 65 CLEVIS TYPE. 2-j' NOMINAL AND OVER, USE GRINNELL NO. 260 CLEVIS TYPE. PROVIDE SUITABLE HANGER ROOS AND BEAM CLAMPS OR INSERTS. PROVIDE PLASTIC INSERTS OVER HANGERS OR USE COPPER HANGERS FOR COPPER PIPING. IF COPPER PLATED STEEL HANGERS ARE USED, THE STEEL ROO SUPPORTS MUST BE ISOLATED FROM THE HANGER. 2. SUPPORT VERTICAL LINES WITH GRINNELL 261 RISER CLAMP. 3. HANG PIPING FROM BEAMS, GIRDERS, PURLINS, LONG SPAN JOISTS OR FROM ANGLES SUPPLIED AND INSTALLED BY THIS TRADE, SPANNING BETWEEN BEAMS, JOISTS OR OTHER SUPPORTS. 4. HANGERS SHALL BE HUNG FROM STRUCTURAL STEEL MEMBERS WITH APPROPRIATE HANGER CLAMPS. NO WELDING TO OR BURNING, DRILLING OR PUNCHING OF STRUCTURAL STEEL MEMBER BY THIS TRADE, WILL BE PERMITTED UNDER ANY CIRCUMSTANCES. VENT PIPING: 1. VENT PIPING UP TO AND INCLUDING 4' SHALL BE DWV-PVC. PROVIDE ALL FIXTURES WITH TRAPS AND VENTS. 2. ALL VENT CONNECTIONS SHALL BE WITHIN 5'-0' OF THE TRAP AND NOT CLOSER THAN ONE DIAMETER OF THE TRAP PIPE SIZE. 3. A VENT MAY BE CONNECTED TO A VENT STACK. ALL VENTS SHALL CONTINUE TO RISE AFTER LEAVING THE TRAP AND TERMINATE IN A VENT THRU ROOF WHERE SHOWN ON THE DRAWINGS. VALVES: 1. ALL EXPOSED FIXTURE STOPS SHALL BE CHROME PLATED. 2. VALVES SHALL BE THE SAME SIZE AS THE PIPE IN WHICH THEY ARE INSTALLED. EXPANSION JOINTS: 1. AT HOT WATER LINES, USE FLEXONIC EXPANSION COMPENSATORS MODEL HB, PRESSURE EXTERNAL TO THE BELLOWS, DESIGNED FOR MAXIMUM WORKING PRESSURE OF 150 PSI. 2. ALLOW FOR EXPANSION IN VERTICAL RUNS TO COMPENSATE FOR TEMPERATURE AND BUILDING STRUCTURAL MOVEMENTS. FLOOR DRAINS: 1. INSTALL ALL FLOOR DRAINS WITH TRAP PRIMERS CONNECTED TO NEAREST COLO WATER FLUSH VALVE. ALL FLOOR DRAIN TRAPS SHALL BE VENTED. 2. COOPERATE WITH GENERAL CONTRACTOR TO ESTABLISH FLOOR DRAIN LEVELS. PIPING INSULATION: 1. INSTALL WATER OVERHEAD, STRAIGHT, PARALLEL OR PERPENDICULAR TO STRUCTURE AND WALLS. USE STANDARD FITTINGS FOR DIRECTION CHANGES. 2. INSTALL GROUPS OF PIPING PARALLEL TO EACH OTHER WITH SPACE TO PERMIT APPLICATION OF INSULATION, IDENTIFICATIONS, AND SERVICE ACCESS, ON TRAPEZE HANGERS. 3. INSTALL ECCENTRIC REDUCERS IN HORIZONTAL PIPING TO PERMIT DRAINAGE AND ELIMINATE AIR POCKETS. 4. SHALL BE FREE FROM SURFACE DAMAGE. REPLACE ANY DAMAGED PIPE OR TUBING. 5. 6. INSTALL FLANGES OR UNIONS TO PERMIT REMOVAL OF EQUIPMENT WITHOUT DISTURBING PIPING SYSTEMS. 7. ASSEMBLE JOINTS WITHOUT BENDING. B. ALL HANGERS AND ROOS SHALL BE OF A SIZE AND WEIGHT TO SAFELY SUPPORT THE PIPE SYSTEMS. 9. ALL HANGERS MUST BE SUITABLE FOR TYPE OF MATERIALS BEING SUPPORTED TO PREVENT ELECTROLYSIS AND ABRASION. 10. PIPING UP TO AND INCLUDING 2' SHALL BE SUPPORTED EVERY 8'-0'. PIPING 2-j' AND OVER SHALL BE SUPPORTED EVERY 10'-0'. PLUMBING FIXTURE SCHEDULE: L-1 LAVATORY - AMERICAN STANDARD 'AQUALYN' NO. 0475.047, SELF RIMMING, VITREOUS CHINA, COUNTER MOUNTED, CENTER HOLE ONLY, WHITE. INSTALL 2-j' FROM FRONT EDGE OF COUNTERTOP. FAUCET HYDROTEK NON -MIXING AUTOMATIC FAUCET MODEL H-2603C(AC), SOLID BRASS, CHROME PLATED, SINGLE HOLE MOUNT. PROVIDE STANDARD PACKAGE WITH OPTIONAL HBL-02 THERMOSTATIC MIXING VALVE WITH CHECKS. PROVIDE HC-010 MULTI -UNIT POWER ADAPTER (ONE PER GROUP TOILET ROOM) MCGUIRE MFG. CO. NO. 155A CAST BRASS CHROME PLATED OPEN GRID P.O. PLUG, SEAMLESS BRASS TAILPIECE; NO. C8872 CHROME PLATED CAST BRASS BODY P-TRAP WITH CLEANOUTj NO 2165CC LAVATORY SUPPLY KIT, CHROME PLATED BRASS STOPS WITH FULL TURN BRASS STEM. V-1 VALVE - AMERICAN STANDARD 'WASHBROOK' NO. 6501.010 TOP SPUD, VITREOUS CHINA, WHITE. FLUSHVALVE HYDROTEK AUTOFLUSH VALVE NO. H-800C (AC), SOLID BRASS CHROME PLATED. CONNECT AUTOFLUSH VALVE TO POWER PROVIDED UNDER FIXTURE L-1. V-2 VALVE - SAME AS V-1 EXCEPT INSTALL IN CONFORMANCE WITH THE FLORIDA ACCESSIBILITY CODE WITH RIM AT 17' AFF. WC-1 WATER CLOSET AMERICAN STANDARD AFWALL ELONGATED FLUSH VALVE TOILET NO. 2257.103 TOP SPUD, VITREOUS CHINA, WHITE. FLUSHVALVE HYOROTEK AUTOFLUSH VALVE NO. H-8000C (AC), SOLID BRASS CHROME PLATED. CONNECT AUTOFLUSH VALVE TO POWER PROVIDED UNDER FIXTURE L-1. SEAT BEMIS NO. 1655C, OPEN FRONT LESS COVER, STAINLESS STEEL CHECK HINGE. WC-1 WATER CLOSET - AMERICAN STANDARD 'YORKVILLE' 1.6 GPF RIGHT HEIGHT ELONGATED PRESSURE ASSISTED TOILET, NO. 2878.016.020, WHITE (020), 30.75- x 20.5' x 29.75' FO FLOOR DRAIN - STRAINERS TO BE POLISHED NICKEL BRONZE TOP, VANDAL PROOF SECURED. 21412al 0 kalmm� LOCATION DOMESTIC PLAN 1/4 to = 1 $-C 4/ 0 21 4/ 2- 2' SAN ITARY PLA,N 1/4 of = 1 1-099 4/ 0 21 4/ 12- V N, LAV 1 2" 11� 41�4' VTR I . ix 'N� � 1 -1 12 V CO WC 12" V 3' 1 2/ MS 3- LAV 3- WC WC FD W wc C FID PLUMBING SANITARY RISER IN N, UR 2" V UR WC �_41_AV LAV N, N 2 " 1 2" V " f (LA K, z1qf CO FIELD VERIFY LOCATION OF 4 SANITARY LINE TIE-IN DOMESTIC LEGEND SINK TOILET "W hLA URINAL DOMESTIC LINES PIPE SIZE C: COLD H: HOT DOMESTIC TIE-IN SANITARY LEGEND LAV LAVATORY WC TOILET UR URINAL -0 MS MOP SINK SANITARY LINES VENT LINES 11 FD FLOOR DRAIN SANITARY TIE-IN VERTICAL STACK L tit 111C kr,, It �_q r- 170 L_ 0 0 F�" MA "__j 0 an W_j C)e rl� ine 0 U 0 cn 0 C_.) M (3) r4,) C.0 L0 C) 00 E 0 0 Lo > to 04 00 LO 04 cm W c) a) r--: PC) V) LO CO LO U-) Lj C14 co En CR C:) M C) R V) ro V) C) C) LO C:) C/) C:) r'.) to - 00 U- 19CO29 cf) Q) C14 LO c- U LL_ :E 0- V) U) Q) M c- NO C) Lr) review 06-24-2019 approval 07-29-2019 permit revision revision P- 101, 91� '��o31II rnJ�;E�zo ��Itili,�.���u�S�'�n d���'�3'�-S