HomeMy WebLinkAbout5315 5th StREPAIR/RESTORATION OF PORCII
APPLICABLE CODES AND STANDARDS
2017 FLORIDA
BUILDING CODE - RESIDENTIAL, SIXTH EDITION
2017 FLORIDA
BUILDING CODE - BUILDING, SIXTH EDITION
2017 FLORIDA
BUILDING CODE - ENERGY CONSERVATION, SIXTH EDITION
NFPA 70 - NATIONAL ELECTRICAL CODE, 2014 EDITION
2017 FBC BUILDING CODE - EXISTING BUILDING, SIXTH EDITION
CHAPTER 6 -
REPAIRS
SECTION 601
- GENERAL
SECTION 602
- BUILDING ELEMENTS AND MATERIALS
SECTION 606
- STRUCTURAL
SECTION 706
- EXISTING ROOFING
SCOPE: THE EXISTING SCREENED PORCH WAS DAMAGED BY A VEHICLE
CRASHING INTO IT. THE REPAIR / RESTORATION OF THE PORCH WILL
CONSIST OF MATCHING ORIGINAL CONFIGURATION, HEIGHT, SIZE, LIKE
MATERIALS, ROOF SLOPE AND ORIGINAL METHOD OF CONSTRUCTION.
BUILDING CODE ANALYSIS
OCCUPANCY TYPE:
GROUP R
CLIMATE ZONE: 2A PASCO
REQUIRED:
INSULATION IN ATTIC: R-38
MASS (CMU WALL): R-7.6
WOOD FRAME: R-13 + R-3.8 OR R-20
PROVIDED:
NOT APPLICABLE, OPEN SPACE NON -HEATED AREA.
CONSTRUCTION TYPE: VB
TABLE 504.3; ALLOWABLE BUILDING HEIGHT = 40 FEET
TABLE 504.4; ALLOWABLE NUMBER OF STORIES = 3
TABLE 506.2; ALLOWABLE AREA = UNLIMITED SF
TABLE 601 - BUILDING ELEMENT
FIRE -RESISTANCE RATING REQUIREMENTS (HOURS)
TYP E V
8
PRIMARY STRUCTURAL FRAME
0
BEARING WALLS
EXTERIOR
INTERIOR
0
0
NONBEARING WALLS AND PARTITIONS TABLE 602
EXTERIOR 10 < X < 30
0
NONBEARING WALLS AND PARTITIONS
INTERIOR
0
FLOOR CONSTRUCTION AND ASSOCIATED SECONDARY MEMBERS
0
ROOF CONSTRUCTION AND ASSOCIATED SECONDARY MEMBERS
0
SQUARE FOOTAGE BREAKDOWN
RESIDENCE:
FLOOR (LIVING AREA) HEATED - A/C SPACE: 1,488 SF
GARAGE: 528 SF
PATIO: 240 SF
SCREENED PORCH: (RECONSTRUCTED) 200 SF
TOTAL SQUARE FOOTAGE: 2,456 SF
PRODUCT APPROVAL
PRODUCT
CATEGORY
MANUFACTURER
SUB CATEGORY
MATERIAL
FLORIDA
APPROVAL #
ROOFING
GAF
ASPHALT SHINGLES
ASPHALT
FL1 0124.1
ROOFING
CERTAINTEED CORP.
ASPHALT SHINGLES
ASPHALT
FL5444
NOTE:
IF OWNER OR CONTRACTOR WANTS TO USE A DIFFERENT PRODUCT, CONTRACTOR SHALL
SUBMIT COPY OF PRODUCT APPROVAL DOCUMENTATION TO BUILDING DEPARTMENT.
5315 5TH STR T,
PHYRHI S, F ORIDA 33542
chul, Christ
Subway Restau rw
AutoZane Auto Parts Zephyrhil
The Broach School Public Libra
(7-EPHYR,H ILLS-)
r I
_61P IF531-15 5th Street
Greut Starl
'D
Learning Center
Gc-In" Po
Mike Keys
'all'i Ave Locks m ith Servi c4-,
hllyne�" i ._.L:ount
mo�� Home
First Baptisst Chui
Tenney's, Custom A%
Saddlepyy U:-j (:54)
C3-
PROJECT LOCATION MAP: 5315 5TH STREET, ZEPHYRHILLS, FL 33542
PARCEL ID: 11-26-21-0010-12400-0070
CLASSIFICATION: 00100 - SINGLE FAMILY
LEGAL DESCRIPTION:
CITY OF ZEPHYRHILLS PB 1 PC 54
LOTS 7, 8 & NORTH 10.00 FT LOT 9
BLOCK 124 OR 7753 PC 1561
YEAR BUILT: 1979
GENERAL NOTES:
1. DO NOT SCALE DRAWINGS TO OBTAIN DIMENSIONAL INFORMATION.
2. PLUMBER TO INFORM GENERAL CONTRACTOR OF ANY VENTING, WHICH UTILIZES
A MASONRY WALL TO RESOLVE ANY POSSIBLE STRUCTURAL INTEGRITY ISSUES.
3. NOTES, TYPICAL DETAILS AND SCHEDULES APPLY TO ALL STRUCTURAL
WORK UNLESS OTHERWISE NOTED. FOR CONDITIONS NOT SPECIFICALLY
SHOWN, PROVIDE DETAILS OF A SIMILAR NATURE. VERIFY
APPLICABILITY BY SUBMITTING SHOP DRAWINGS FOR REVIEW.
4. STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH THE
SPECIFICATIONS, ARCHITECTURAL, ELECTRICAL, PLUMBING AND MECHANICAL
DRAWINGS. IF THERE IS A DISCREPANCY BETWEEN DRAWINGS IT IS THE CONTRACTOR'S
RESPONSIBILITY TO NOTIFY THE ENGINEER PRIOR TO PERFORMING WORK.
5. TOP OF CONCRETE SLABS ARE AT FLOOR REFERENCE ELEVATIONS
EXCEPT AS NOTED.
6. AT ALL TIMES THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR
THE CONDITIONS OF THE JOBSITE INCLUDING SAFETY OF PERSONS
AND PROPERTY. THE ARCHITECT'S OR ENGINEER'S PRESENCE OR
REVIEW OF WORK DOES NOT INCLUDE THE ADEQUACY OF THE
CONTRACTOR'S MEANS OR METHODS OF CONSTRUCTION,
7. INTERIOR WALL AND CEILING FINISH.
FINISH MATERIALS SHALL BE CLASS A, CLASS B OR CLASS C.
V11-111 RjEVAlLjjVG
000j5p,
7 -
DRAWINGS INDEX
SHEET DESCRIPTION
A-0
COVER SHEET - CODE ANALYSIS
A-1
GENERAL NOTES
A-2
DEMOLITION PLAN
A-3
FLOOR AND FOUNDATION PLANS
A-4
ELECTRICAL PLAN
A-5
ROOFPLAN
A-6
ROOF FRAMING PLAN
A-7
EXTERIOR ELEVATIONS
A-8
TYPICAL DETAILS
ENGINEER'S EXCLUSION TABLE:
1. EXISTING CONNECTIONS OUTSIDE OF SCOPE OF WORK,
2. FIREPROOFING.
3. ENVELOPE / WATERPROOFING.
4. M.E.P. DESIGN.
5. EXISTING FOUNDATION ANALYSIS.
6. FLOOR / WALL FRAME AND WEATHER PROTECTION SYSTEM OUTSIDE OF
SCOPE OF WORK.
7. FINISH MATERIALS.
8. TERMITE INSPECTION / REMEDIATION.
9. MEANS AND METHODS.
10. CONSTRUCTION SAFETY.
THE ENGINEER IS RESPONSIBLE FOR ELEMENTS OF THE SIGNED AND SEALED
DRAWINGS. ITEMS LISTED IN THE ENGINEER EXCLUSION TABLE ARE EXCLUSIONS
OF THE ENGINEER'S RESPONSIBILITY AND ARE NOT EXCLUSIONS OF RETROFIT
RELATED TO OR NEEDED TO COMPLETE THE PROJECT. ALL RETROFIT WORK
WILL BE THE RESPONSIBILITY OF A LICENSED CONTRACTOR.
SCOPE OF WORK
THE EXISTING SCREENED PORCH WAS DAMAGED BY A VEHICLE
CRASHING INTO IT. THE REPAIR / RESTORATION OF THE PORCH WILL
CONSIST OF MATCHING ORIGINAL CONFIGURATION, HEIGHT, SIZE,
LIKE MATERIALS, ROOF SLOPE AND ORIGINAL METHOD OF
CONSTRUCTION. THE PROPERTY IS A 1-STORY SINGLE FAMILY HOME
LOCATED IN ZEPHYRHILLS, FLORIDA
ARCHITECT'S OR ENGINEER'S AFFIDAVIT STATEMENT
TO THE BEST OF THE ARCHITECT'S OR ENGINEER'S KNOWLEDGE, THE PLANS
AND SPECIFICATIONS COMPLY WITH THE APPLICABLE MINIMUM BUILDING CODES
AND THE APPLICABLE FIRE SAFETY STANDARDS AS DETERMINDED BY LOCAL
AUTHORITY IN ACCORDANCE WITH THIS SECTION AND CHAPTER 633, FLORIDA STATUTES.
2
0
y
11:4w�
z
Ln
r2 z zi
14 0
P41-4
w C/)
P4 P4
z C:)
LAz Z
MP4 <�
Issued for:
Date:
El PRELIMINARY
El PRICING
El BIDDING
0 PERMIT
12/27/2019
E REVISION #1
Ln
66
Ln
PEN"I
'p"
Ln
P=
Ln
Feel
License Number: 73539
[ rawn by: A=O SE, PE
D FRANK DE-JO,
GENERAL NOTES,& SPECIFICATIONS
I - STRUCTURAL CODES
1. 2017 FLORIDA BUILDING CODE, RESIDENTIAL 6TH EDITION
2. AMERICAN FOREST & PAPER ASSOCIATION "NATIONAL DESIGN
SPECIFICATION FOR WOOD CONSTRUCTION", 2012 ("AF&PA").
3. NATIONAL DESIGN STANDARD FOR METAL PLATE CONNECTED
WOOD TRUSS CONSTRUCTION
4. ASCE/SE1 7-16, AC1318-2014, MSJC 2013
UNLESS OTHERWISE SHOWN OR NOTED ON DRAWINGS:
1. RETROFIT TIMBER
SOUTHERN PINE No.1 (Fb=1200 PSI).
PRESSURE TREATED
2. CAST -IN -PLACE CONCRETE:
FOUNDATIONS: .................................................................... 3 KS1 NORMAL WT
3. REINFORCEMENT:
DEFORMED BARS:
WELDED WIRE FABRIC:
ASTM A615, GRADE 60.
ASTM Al 85.
1. NOTES, TYPICAL DETAILS AND SCHEDULES APPLY TO ALL STRUCTURAL
WORK UNLESS OTHERWISE NOTED. FOR CONDITIONS NOT SPECIFICALLY
SHOWN, PROVIDE DETAILS OF A SIMILAR NATURE. VERIFY
APPLICABILITY BY SUBMITTING SHOP DRAWINGS FOR REVIEW.
2. IF THERE IS A DISCREPANCY BETWEEN DRAWINGS IT IS THE CONTRACTOR'S
RESPONSIBILITY TO NOTIFY THE ENGINEER PRIOR TO PERFORMING WORK.
3. DO NOT SCALE DRAWINGS TO OBTAIN DIMENSIONAL INFORMATION.
4. AT ALL TIMES THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR
THE CONDITIONS OF THE JOBSITE INCLUDING SAFETY OF PERSONS
AND PROPERTY. THE ARCHITECT'S OR ENGINEER'S PRESENCE OR
REVIEW OF WORK DOES NOT INCLUDE THE ADEQUACY OF THE
CONTRACTOR'S MEANS OR METHODS OF CONSTRUCTION.
5. SHORING, BRACING AND PROTECTION OF EXISTING AND ADJACENT
STRUCTURES DURING CONSTRUCTION IS THE SOLE RESPONSIBILITY
OF THE CONTRACTOR. PROTECT AND MAINTAIN THE INTEGRITY OF
ADJACENT STREETS, BUILDINGS AND STRUCTURES.
6. ALL EXISTING DIMENSIONS AND LOCATIONS OF EXISTING STRUCTURES
SHOWN ON THE DRAWINGS SHALL BE VERIFIED BY FIELD MEASUREMENTS,
ANY DISCREPANCIES SHALL BE REPORTED TO THE ENGINEER.
7. DRAWINGS HAVE BEEN PREPARED BASED ON AVAILABLE KNOWLEDGE OF
EXISTING CONDITIONS. IF, DURING DEMOLITION, EXCAVATION OR
CONSTRUCTION, ACTUAL CONDITIONS ARE DISCOVERED TO DIFFER FROM
THOSE INDICATED ON DRAWINGS, ENGINEER SHALL BE NOTIFIED.
1. PRESSURE TREATED (PT) SOUTHERN PINE #2 GRADE OR BETTER
2. THE EXTENT OF WOOD WORK IS SHOWN ON THE DRAWING.
3, KEEP MATERIALS DRY AT ALL TIMES. PROTECT AGAINST EXPOSURE
TO WEATHER AND CONTACT WITH DAMP OR WET SURFACES. STACK
LUMBER AND PROVIDE AIR CIRCULATION WITHIN STACKS.
4. NOMINAL SIZES ARE INDICATED EXCEPT AS SHOWN BY DETAIL
DIMENSIONS; PROVIDE LUMBER COMPLYING WITH GRADING RULES
OF SECTION 10 OF PS 20-94, ASTM D 245, ASTM D 2555.
5. PROVIDE SEASONED DIMENSION LUMBER WITH 19 % MAXIMUM. MOISTURE
CONTENT AT TIME OF DRESSING AND COMPLYING WITH PS 20.
6. LUMBER SHALL BE ENTIRELY OF ONE SPECIES WHICH SHALL NOT
BE LESS THAN THE GRADE REQUIRED ON DRAWINGS.
7. ALL WOOD SHALL BE SOUTHERN PINE No.1 (Fb=1200 PSI). PRESSURE
TREATED SUFFICIENTLY TO RESIST DECAY AND PESTS KNOWN TO BE
PRESENT IN THE PROJECT AREA.
8. FASTENERS AND ANCHORAGES: PROVIDE SIZE, TYPE, MATERIAL AND
FINISH AS INDICATED AND AS RECOMMENDED BY APPLICABLE STANDARDS,
COMPLYING WITH APPLICABLE FEDERAL SPECIFICATION FOR NAIL,
STAPLES, SCREWS, BOLTS, NUTS, WASHERS AND ANCHORING DEVICES.
PROVIDE METAL HANGERS AND FRAMING ANCHORS OF THE SIZE AND TYPE
RECOMMENDED BY THE MANUFACTURER FOR EACH USE INCLUDING
RECOMMENDED NAILS.
9. CARPENTRY WORK ACCURATELY TO REQUIRED LEVELS AND LINES,
WITH MEMBERS PLUMB AND TRUE AND ACCURATELY CUT AND FITTED.
10. SECURELY ATTACH CARPENTRY WORK TO SUBSTRATE BY ANCHORING AND
FASTENING AS SHOWN AND AS REQUIRED BY RECOGNIZED STANDARDS.
COUNTERSINK NAIL HEADS ON EXPOSED CARPENTRY WORK AND FILL HOLES.
11. USE COMMON WIRE NAILS, EXCEPT AS OTHERWISE INDICATED. USE
FINISHING NAILS FOR FINISH WORK. SELECT FASTENERS OF SIZE THAT
WILL NOT PENETRATE MEMBERS WHERE OPPOSITE SIDE WILL BE EXPOSED
TO VIEW OR WILL RECEIVE FINISH MATERIALS. MAKE TIGHT
CONNECTIONS BETWEEN MEMBERS. INSTALL FASTENERS WITHOUT SPLITTING
OF WOOD; PREDRILL AS REQUIRED.
ALL INTERIOR DIMENSIONS ARE GIVEN TO THE INDICATED FACE OF
THE WALL UNLESS NOTED OTHERWISE (NOMINAL SIZE WALLS).
ALL EXTERIOR DIMENSIONS ARE GIVEN TO THE FACE OF THE STUD
OR FACE OF BLOCK (AS APPROPRIATE) WHICH LINES WITH THE
FOUNDATION BELOW.
ALL WOOD IN CONTACT WITH CONCRETE OR MASONRY SHALL BE
PRESSURE TREATED OR APPROVED CEDAR, OR HAVE 15 LB. FELT
BARRIER.
R602.1 GENERAL. WOOD AND WOOD -BASED PRODUCTS USED FOR
LOAD-SUPPOR11NG PURPOSES SHALL CONFORM TO THE APPLICABLE
PRO -VISIONS OF THIS SECTION.
R602.1.1 SAWN LUMBER. SAWN LUMBER SHALL BE IDENTIFIED BY A
GRADE MARK OF AN ACCREDITED LUMBER GRADING OR INSPECTION
AGENCY AND HAVE DESIGN VALUES CERTIFIED BY AN ACCREDITATION
BODY THAT COMPLIES WITH DOC PS 20. IN LIEU OF A GRADE MARK,
A CERTIFICATION OF INSPECTION ISSUED BY A LUMBER GRADING OR
INSPECTION AGENCY MEETING THE REQUIREMENTS OF THIS SECTION
SHALL BE ACCEPTED.
R602.1.2 END -JOINTED LUMBER. APPROVED END -JOINTED LUMBER
IDENTIFIED BY A GRADE MARK CONFORMING TO SECTIONR602.1
SHALL BE PERMITTED TO BE USED INTERCHANGEABLY WITH
SOLID -SAWN MEMBERS OF THE SAME SPECIES AND GRADE.
END -JOINTED LUMBER USED IN AN ASSEMBLY REQUIRED ELSEWHERE
IN THIS CODE TO HAVE A FIRE -RESISTANCE RATING SHALL HAVE
THE DESIGNATION "HEAT RESISTANT ADHESIVE" OR 11HRAFF
INCLUDED IN ITS GRADE MARK.
R602.1.3 STRUCTURAL GLUED -LAMINATED TIMBERS.
GLUED -LAMINATED TIMBERS SHALL BE MANUFACTURED AND
IDENTIFIED ASREQUIRED IN ANSI/AITC A190.1 AND ASTM D3737.
R602.1.4 STRUCTURAL LOG MEMBERS. STRUCTURAL LOG MEMBERS
SHALL COMPLY WITH THE PROVISIONS OF ICC 400.
R602.1.5 STRUCTURAL COMPOSITE LUMBER. STRUCTURAL CAPACITIES
FOR STRUCTURAL COMPOSITE LUMBER SHALL BE ESTABLISHED AND
MONITORED IN ACCORDANCE WITH ASTM D5456.
R602.1.6 CROSS -LAMINATED TIMBER. CROSS -LAMINATED TIMBER
SHALL BE MANUFACTURED AND IDENTIFIED AS REQUIRED BY
ANSI/APA PRG 320.
R602.1.7 ENGINEERED WOOD RIM BOARD. ENGINEERED WOOD RIM
BOARDS SHALL CONFORM TO ANSI/APA PRR 410 OR SHALL BE
EVALUATED IN ACCORDANCE WITH ASTM D7672. STRUCTURAL
CAPACITIES SHALL BE IN ACCORDANCE WITH EITHER ANSI/APA PIRR
410 OR ESTABLISHED IN ACCORDANCE WITH ASTM D7672.RIM
BOARDS CONFORMING TO ANSI/APA PRR 410 SHALL BE MARKED IN
ACCORDANCE WITH THAT STANDARD.
R602.1 GENERAL. WOOD AND WOOD -BASED PRODUCTS USED
FORLOAD-SUPPORTING PURPOSES SHALL CONFORM TO THE
APPLICABLE PRO -VISIONS OF THIS SECTION.
R602.1.8 WOOD STRUCTURAL PANELS. WOOD STRUCTURAL
PANELSHEATHING SHALL CONFORM TO DOC PS 1, DOC PS 2 OR,
WHENMANUFACTURED IN CANADA, CSA 0437 OR CSA 0325.
PANELSSHALL BE IDENTIFIED FOR GRADE, BOND CLASSIFICATION, AND
PER-FORMANCE CATEGORY BY A GRADE MARK OR CERTIFICATE
OFINSPECTION ISSUED BY AN APPROVED AGENCY.
R602.1.9 PARTICLEBOARD. PARTICLEBOARD SHALL CONFORM TOANSI
A208.1. PARTICLEBOARD SHALL BE IDENTIFIED BY THEGRAIDE MARK
OR CERTIFICATE OF INSPECTION ISSUED BY ANAPPROVED AGENCY.
R602.1.10 FIBERBOARD. FIBERBOARD SHALL CONFORM TOASTM C208.
FIBERBOARD SHEATHING, WHERE USED STRUCTUR-ALLY, SHALL BE
IDENTIFIED BY AN APPROVED AGENCY AS CON -FORMING TO ASTM
C208.
R602.2 GRADE. STUDS SHALL BE A MINIMUM NO. 3, STANDARD OR
STUD GRADE LUMBER.
EXCEPTION: BEARING STUDS NOT SUPPORTING FLOORS AND
NON -BEARING STUDS SHALL BE PERMITTED TO BE UTILITY GRADE
LUMBER, PROVIDED THE STUDS ARE SPACED IN ACCORDANCE WITH
TABLER602.3(5).
R602.3 DESIGN AND CONSTRUCTION. EXTERIOR WALLS OF
WOOD -FRAME CONSTRUCTION SHALL BE DESIGNED AND
CONSTRUCTED IN ACCORDANCE WITH THE PROVISIONS OF THIS
CHAPTER AND FIGURES R602.3(l) AND R602.3(2), OR IN
ACCORDANCE WITH AWC NDS.COMPONENTS OF EXTERIOR WALLS
SHALL BE FASTENED IN ACCORDANCE WITH TABLES R602.3(l)
THROUGH R602.3(4). WALL SHEATHING SHALL BE FASTENED
DIRECTLY TO FRAMING MEMBERS AND, WHERE PLACED ON THE
EXTERIOR SIDE OF AN EXTERIOR WALL, SHALL BE CAPABLE OF
RESISTING THE WIND PRESSURES LISTED IN TABLE R301.2(2)
ADJUSTED FOR HEIGHT AND EXPOSURE USING TABLE R301.2(3) AND
SHALL CONFORM TO THE REQUIREMENTS OF TABLE R602.3(3). WALL
SHEATHING USED ONLY FOR EXTERIOR WALL COVERING PURPOSES
SHALL COMPLY WITH SECTION R703.
STUDS SHALL BE CONTINUOUS FROM SUPPORT AT THE SOLE PLATE
TO A SUPPORT AT THE TOP PLATE TO RESIST LOADS
PERPENDICULAR TO THE WALL. THE SUPPORT SHALL BE A
FOUNDATION OR FLOOR, CEILING OR ROOF DIAPHRAGM OR SHALL BE
DESIGNED IN ACCORDANCE WITH ACCEPTED ENGINEERING PRACTICE.
EXCEPTION: JACK STUDS, TRIMMER STUDS AND CRIPPLE STUDS AT
OPENINGS IN WALLS THAT COMPLY WITH TABLES R602.7(l) AND
R602.7(2).
1. ROOF - 15 PSF, ASCE 7-16 TABLE C3-1
LL = 20 PSF
2. FLOORS
FLOOR SLAB: LL= 100 PSF
3. WALLS
CONCRETE BLOCKS: 48" GROUTED 8" CMU: DL= 38 PSF
FRAME WALLS: )/2" PLYWOOD, 2X6 WOOD STUDS AT 16" O.C.: DL= 12 PSF
4. MEAN ROOF HEIGHT SHALL BE DETERMINED BY CONTRACTOR.
5. LATERAL LOADS IN TRUSSES ARE RESISTED BY ROOF DIAPHRAGM AT POINT
OF WIND LOAD INPUT, U.O.N.
6. NO PROVISION HAS BEEN MADE IN THE STRUCTURAL DESIGN FOR TEMPORARY
CONDITIONS OCCURRING DURING CONSTRUCTION, UNLESS SPECIFICALLY NOTED
ON THE STRUCTURAL DRAWINGS. THE CONTRACTOR SHALL PROVIDE ALL
NECESSARY SHORING AND BRACING REQUIRED TO RESIST STRESSES OR
INSTABILITY OCCURRING FROM ANY CAUSE DURING CONSTRUCTION. THE
CONTRACTOR SHALL ASSUME COMPLETE RESPONSIBILITY FOR SUCH MEASURES.
7. ALLOWABLE DEFLECTION: LL = 1/360; DL + LL = 1/240
1. THIS BUILDING IS DESIGNED AS A FULLY ENCLOSED BUILDING ON ALL OPENINGS
BEING PROTECTED OR HAVING MISSILE IMPACT GLASS.
2. WIND DESIGN LOADS WERE DETERMINED AND BASED ON:
BASIC WIND SPEED, (3-SEC GUST) .................................................. 138 MPH
BUILDING CATEGORY ...................................................................................... 11
WINDEXPOSURE ............................................................................................ B
INTERNAL PRESSURE COEFFICIENT ................................................... +/-0.55
ENCLOSURETYPE. ................................................................ PARTIALLY ENCLOSED
1. CONNECTIONS SHOWN ARE RECOMMENDED, BUT OTHER CONNECTIONS MAY BE
SUBSTITUTED AS LONG AS THEY MEET OR EXCEED UPLIFTS AND LATERAL
CAPACITY OF THE ANCHORS SPECIFIED AND SATISFY TRUSS LAYOUT REQUIREMENTS
COMPLIANCE WITH USP, SIMPSON OR OTHER MANUFACTURER'S REQUIREMENTS.
2. FOR ADDITIONAL TIE DOWN INFORMATION, SEE SIMPSON OR USP CATALOGS.
3. FOR POST -INSTALLED ANCHORS; HOLE PREPARATION, CARTRIDGE PREPARATION,
AND EPDXY FILLING SHALL BE PERFORMED PER MANUFACTURER'S ADHESIVE
ANCHOR INSTALLATION INSTRUCTIONS.
1. REINFORCING STEEL SHALL HAVE A MINIMUM CLEAR COVER AS FOLLOWS,
U.O.N. IN DRAWINGS:
CONCRETE POURED AGAINST EARTH .................................. 3"
CLEAR COVER SHALL BE CLEARLY SHOWN ON ALL REBAR DETAIL DRAWINGS.
2. ALL REINFORCEMENT SHALL BE SECURELY HELD IN POSITION WHILE
PLACING CONCRETE. IF NECESSARY, ADDITIONAL BARS SHALL BE
PROVIDED BY THE CONTRACTOR TO FURNISH SUPPORT.
4. WHERE INDICATED ON FLOOR PLANS, PROVIDE CONCRETE FILLED CELL WITH
REINFORCING STEEL FROM FOOTING TO TIE BEAM HOOKED & TIED BEFORE
INSPECTION. IF GROUT LIFT EXCEEDS 4'-0", AN INSPECTION HOLE TO VERIFY
GROUTING SHALL BE PROVIDED AT THE BOTTOM CELL.
5. LOCATION OF ALL CONSTRUCTION JOINTS NOT SHOWN IN DRAWINGS SHALL
BE SUBMITTED TO ENGINEER FOR APPROVAL PRIOR TO DETAILING OF
REINFORCING. ALL CONSTRUCTION JOINTS TO BE CLEARLY SHOWN IN REBAR
DETAIL DRAWINGS. ENGINEER MAY REQUIRE ADDITIONAL REINFORCING AT
CONSTRUCTION JOINTS.
7� DIMENSIONS Id" AS NOTED ON DRAWINGS SHALL CORRESPOND --TO THE
FOLLOWING LENGTHS IN INCHES AS SHOWN IN THE TABLES BELOW.
8. ALL LAP SPLICES SHALL BE 1.3LD UNLESS NOTED OTHERWISE ON
DRAWINGS.
9. FOR LIGHTWEIGHT AGGREGATE CONCRETE, MULTIPLY THE TABULATED
VALUES BY 1.3.
1. STRUCTURAL CONCRETE MASONRY, AS SHOWN ON THESE DRAWINGS,
SHALL HAVE A COMPRESSIVE STRENGTH (F'M) OF 3,500 PSI.
2. MASONRY UNITS SHALL CONFORM TO ASTM C90, TYPE 11, NORMAL
WEIGHT, HOLLOW UNLESS SPECIFICALLY NOTED OTHERWISE ON
THESE DRAWINGS, WITH A UNIT STRENGTH AS REQUIRED TO ACHIEVE
COMPRESSIVE STRENGTH SPECIFIED ABOVE.
3. MORTAR SHALL CONFORM TO ASTM C270, TYPE M OR S FOR ABOVE
GRADE, TYPE M FOR BELOW GRADE.
4. GROUT FOR FILLED CELLS SHALL CONFORM TO ASTM C476 WITH
3000 PSI STRENGTH AT 28 DAYS. CELLS SHALL BE GROUTED IN
INCREMENTS NOT EXCEEDING 5 FEET VERTICALLY. FILL ALL CELLS
BELOW GRADE.
5. VERTICAL REINFORCING SHALL BE ASTM A615, GRADE 60 DEFORMED
BARS. MINIMUM LAP SPLICES SHALL BE AS FOLLOWS:
# 3 BARS - V-6"
# 4 BARS - 2'-0"
# 5 BARS - 2'-6"
# 6 BARS - S-O"
6, HORIZONTAL REINFORCING SHALL BE NO. 9 GAGE "DUROWALL" OR
EQUIVALENT AND SHALL BE PLACED EVERY OTHER COURSE U.O.N.
7. ALL BLOCK SHALL BE PLACED IN RUNNING BOND.
52
1
53
MWFRS Wind Load for
Load Case A
MWIFIRS
Wind Load fbr Load Case B
54
Surface
GCpf
p = Net Pressures (psf)
Surface
I�GC:pf
p =: Not Pressures (psf)
(wl +GCpi)
(w/ -GCpi)
(WI +GCpi)
(w/ -GCpi)
55
56
Zone 1
0.40
-4.35
27,5 8
Zone 1
-0-45
-29-03
'-36-'00
2_90
57
Zone 2
-0-69
-36'.-00
-4-06-,
Zone 2
-0'-69-
-4.06--
58
Zone 3
-0.37
-26.71
5.23
Zone 3
-0.37
-26.71
5_23
59
Zone 4
-0.29
-.24-39
7_55
Zone 4
-0-45
-29.03
2-90
601
Zone 5
Zone 5
0.40
-4-35
27.58
61
Zone 16
Zone 6,
-0-29
-24.39
7-55
62
Zone I E
O�61
1-74
33-68
Zone 1 E
-0-48
-29�90
2-03
63
Zone 2E
-1-07
-47-03
-15.10
Zone 2E
-1-07
-47.03
-15-10
64
Zons 3E
-0-53
-31-35
0�58
Zone 3E
-0-53
-31.35
0.518
65
Zone 4E
-0-43
-28-45
3.48
Zone 4E
-0-48
-29M
2-03
66
Zone 5E,
Zane 5,E
0.61
1.74
3168
67
Zone 6E
-
Zone 6E
-0-43
-2&45
3.48
68
69
*N2ote- Use roof angle 0 0 degrees for Longitudinal Direction-
70
For Case A when GCpf is neg- in Zones 212C For Case B when GCpf is neg- in Zones 2/2E,
Zones 212E dist.
* ! ft., Zones 2/2E dist.
72 11 Remainder of roof Zones 2/2E extending to ridge line shall use roof Zones, 3/3E pressure coefficients
Me 1 rem WOT-Tol ROMMI'm
Zcyne 1 T
-1 �.09
Zone 1T
-7.26
0.73
Zone 2T
-9-00
Zone 2T
-9.00
-1-02
Zone 3T�
-6-68
Zone 3T
-6,68
1.31
Zone, 4T
-6. 10
Zone 4T
-7-26
0.73
Zone 5T
Zone 5,T
-1.09
6-90
zone 6T
Zone 6T
_&10
1.89 1�
-t TF�
III,-#EU* Mug W[*j1rjvL!Um
Awl
LDrawn by: FRANK DE-JOSE, PE
0
y
rl,,D
z
0 WA
(Z won%
6Tl
%
z
09 Ln
r2zz
IP-40
rx "
p4cr)
W W
40
LAzz
M P4 <4
Issued for: Date:
El PRELIMINARY
0 PRICING
E BIDDING
E PERMIT 12/27 019
El REVISION #1
LM
C
LM
Ln
IMM
v
L
00 Seal
License Number: 73539
0
y
rl,,D
z
0 WA
(Z won%
6Tl
%
z
09 Ln
r2zz
IP-40
rx "
p4cr)
W W
40
LAzz
M P4 <4
Issued for: Date:
El PRELIMINARY
0 PRICING
E BIDDING
E PERMIT 12/27 019
El REVISION #1
LM
C
LM
Ln
IMM
v
L
00 Seal
License Number: 73539
24$-0)'
EXISTING PORCH CONCRETE
EXISTING EXTERIOR WALL AND SLAB TO REMAIN
TRUSS FRAMING TO BE REVIEWED
0
TO ENSURE DAMAGE MEMBERS I SCREENED PORCH
ARE IDEN11FIED AND REMOVED.
NOTIFY ENGINEER OF ANY
DAMAGE MATERIALS. EXISTING ALUMINUM SCREEN DOOR
TO BE REMOVED
EXISTING SCREENING, WOOD
FRAMING AND CMU WALL
TO BE REMOVED
DEMOLITION
CALE: 1/4 )1 = 1
24'—Op$
EXISTING SCREENING, WOOD
FRAMING AND CMU WALL
TO BE REMOVED
GENERAL DEMOLITION NOTES:
1. THE CONTRACTOR SHALL BE FAMILIAR WITH AND PERFORM ALL REMOVAL WORK IN ACCORDANCE WTH
FLORIDA BUILDING CODE CHAPTER 33, "SAFEGUARDS DURING CONSTRUCTION" .
2. THE CONTRACTOR SHALL PROVIDE TEMPORARY SHORING AND SAFETY PROTECTION DURING DEMOLITION
PERIOD AS REQUIRED BY BUILDING CODE CHAPTER 33 TO PROPERLY PERFORM THE WORK.
3. SHORING, BRACING AND PROTECTION OF EXISTING AND ADJACENT STRUCTURES DURING CONSTRUCTION
IS THE SOLE RESPONSIBLE OR THE CONTRACTOR. PROTECT AND MAINTAIN THE INTEGRITY OF
ADJACENT BUILDING AND STRUCTURES.
ALTER OR DAMAGE THE FLOOR OR CEILING SLABS, EXCEPT AT AREAS NOTED ON PLAN,
5. WHERE EXISTING FINISH SURFACE IS TO REMAIN, REPAIR AND PATCH ALL LOCATIONS ASSOCIATED
WITH DEMOLITION AND REMOVAL OF ADJACENT FINISHES, FRAMING, ETC..
ALL MATERIALS, DOORS & FRAMES, FINISHES THAT ARE TO REMAIN AT COMPLETION.
7. ALL ITEMS TO BE REMOVED ARE SHOWN WITH DASHED / HIDING LINES. REMOVE ENTIRE PARTITIONS;
INCLUDING BUT NOT LIMITED TO GYPSUM BOARD, STUDS, FASTENERS, FINISHES AND BUILDING UTILITIES
WITHIN PARTITION. RE—ROUTE, CUT AND CAP OFF UTILITIES WITHIN WALLS AS REQUIRED.
8. REMOVE ALL FLOOR FINISHES IN THEIR ENTIRELY, DOWN TO THE ORIGINAL FLOOR SLAB / DECK;
INCLUDING BUT NOT LIMITED TO CERAMIC TILES, CARPETS OR VINYL COMPOSITION TILES,
9. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR THE CONTRACTOR'S MEANS OR METHODS OF
CONSTRUCTION AND CONDITIONS OF THE JOBSITE INCLUDING SAFETY OF PERSONS AND PROPERTY.
10. ALL EXISTING DIMENSIONS AND LOCATIONS OF EXISTING STRUCTURES SHOWN ON THE DRAWINGS
SHALL BE FIELD VERIFIED, ANY DISCREPANCIES SHALL BE REPORTED THE DESIGNER OF RECORD.
11. DRAWINGS HAVE BEEN PREPARED BASED ON AVAILABLE KNOWLEDGE OF EXISTING CONDITIONS. IF
DURING DEMOLITION OR CONSTRUCTION, ACTUAL CONDITIONS ARE DISCOVERED TO DIFFER FROM THOSE
INDICATED ON DRAWINGS, THE DESIGNER OF RECORD SHALL BE NOTIFIED.
r2zz
P-4 (.9
P4 P-4
W(/)
P4 P4
z
LL:
Issued for:
Date:
El PRELIMINARY
El PRICING_
El BIDDING
0 PERMIT
12/27/2019
El REVISION #1
MINIMUM SLAB PROVISIONS
1907.1 General. The thickness of concrete floor slabs supported directly on the
ground shall not be less than 3 1/2 inches (4" min. specified on plans). A 6—mil
(0.006 inch; 0.15 mm) polyethylene vapor retarder with joints lapped not less than 6
inches (152 mm) shall be placed between the base course or subgrade and the
concrete floor slob, or other approved equivalent methods or materials shall be used
to retard vapor transmission through the floor slab.
I N L- VV I-) �-/ I \ L- L- I I I I N \J r\ I
WOOD FRAMING OPENING
2)-0111. 3)-4)) 1- 12'-0"
I ) I
14 — 0 1 20'-0"
7-LOOR PLAN - RENOVATED
SCALE: 3/8" = 1'-0"9
14 1-0))
SCALE: 3 8' = 1 1-0"
1 1111
1 - 4
14 — 0
- - ' -- \ - - - - 1 0 �-,IVIU VVI 11-1 U111—L-) ruur,\Lu
MATCH EXISTING HEIGHT, SOLID WITH (1) #5 BAR FROM
FINISH, ETC. FOOTING TO BOND BEAM / LINTEL
2 14 4 12'- 0 EPDXY W/ HILTI HIT-HY500 (OR EQUAL)
1 -4 MIN. EMBED 6" (TYP)
20 �-01)
14'— 0 P)
Ott LM
r2zz
1-10
z C)
U0z Z
M
Issued for: Date:
El PREUMINARY
0 PRICING
F-1 BIDDING
0 PERMIT 12/27/2019
El REVISION #1
:J
F,
C
LM
LM
LIM P=
T-111 ;"
Lm
00
Sea[
License Number: 735394
A=3
Qrswn bY: FRANK DE40SE, PE )
Qrswn bY: FRANK DE40SE, PE )
ELECTRICAL OUTLET MOUNTING HEIGHTS
PADDLE FAN SWITCH
(LOCATE OVER FAN
LIGHT SWITCH)
LIGHT SWITCH
DUPLEX OUTLET AT
KITCHEN COUNTER, REFRIG.,
WASHER AND GARAGE OUTLETS
DUPLEX OUTLET AT
VANITY COUNTER
STANDARD
DUPLEX OUTLET
00
ELECTRICAL GENERAL NOTES:
1. ELECTRICAL CONTRACTOR SHALL COMPLY WITH
NFPA 70 (NEC) NATIONAL ELECTRICAL CODE 2014
EDITION.
2. OUTLETS LOCATIONS SHOWN ARE FOR REFERENCES
PURPOSES ONLY, CONTRACTOR TO COMPLY WITH NEC
OUTLETS SPACING REQUIREMENTS PER CODE.
3. ALL ELECTRICAL WORK IS SUGGESTED; MUST BE
VERIFIED AND COMPLETED BY A LICENSED ELECTRICAL
CONTRACTOR.
ELECTRICAL NOTES
ALL WORKMANSHIP AND MATERIALS SHALL CONFORM TO ALL APPLICABLE CODES SUCH AS THE NFPA 70,
NATIONAL ELECTRICAL CODE 2014 EDITION, LOCAL ORDINANCES AND POWER COMPANY REGULATIONS.
SUBCONTRACTOR SHALL BE LICENSED, CARRY ALL APPLICABLE INSURANCE, AND HAVE A CURRENT
COUNTY OCCUPATIONAL LICENSE.
SUBCONTRACTORS SHALL INCLUDE ALL SPECIAL FEES AND PERMITS,. LABOR AND MATERIAL, EQUIPMENT
AND ELECTRICAL ENGINEERING NECESSARY TO PROVIDE AN APPROVED WORKING SYSTEM. LIGHT FIXTURES
EXCLUDED EXCEPT FOR FLUORESCENT FIXTURES AND RECESSED LIGHTS.
210.12 ARC —FAULT CIRCUIT —INTERRUPTER PROTECTION.
(A) DEFINITION: ARC —FAULT CIRCUIT INTERRUPTER (AFCI). A DEVICE INTENDED TO PROVIDE PROTECTION
FROM THE EFFECTS OF ARC FAULTS BY RECOGNIZING CHARACTERISTICS UNIQUE TO ARCING AND BY
FUNCTIONING TO DE —ENERGIZE THE CIRCUIT WHEN AN ARC FAULT IS DETECTED.
(B) DWELLING UNITS. ALL 120—VOLT, SINGLE PHASE, 15— AND 20—AMPERE BRANCH CIRCUITS SUPPLYING
OUTLETS INSTALLED IN DWELLING UNIT FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, DENS, BEDROOMS,
RECREATION ROOMS, CLOSETS, HALLWAYS, OR SIMILAR ROOMS OR AREAS SHALL BE PROTECTED BY A
LISTED ARC —FAULT CIRCUIT INTERRUPTER, COMBINATION —TYPE, INSTALLED TO PROVIDE PROTECTION OF
THE BRANCH CIRCUIT.
TO EXISTING SWITCH
Wp SCREENED PORCH
13,61-
(`l� ELECTRICAL PLAN'
�A-4) SCALE: 3/8 �l = 1 141
Wp 41
1�4
SURFACE CEILING MOUNTED LIGHTS
EXTERIOR WATER PROOFED WALL OUTLET 110
WIP NOTE:
ALL LIGHT FIXTURES TO BE SELECTED
AND PROVIDED BY OWNER.
No
NOTE:
THIS IS ONLY A SUGGESTED
ELECTRICAL LAYOUT,
z
6TO4
%
Z
Ln
r2z z
0-40
cl�-4
z
L Z Z
00 Issued for: Date -
El PRELIMINARY
El PRICING
El BIDDING
E PERMIT 12/27/2019
El REVISION #1
0
Ln
Ln
PENN
, p"
P=
LIM P=
Seal
v
License Number: 735
%
A=4
Q rawn by: FRANK DE-JOSE, PE
Q rawn by: FRANK DE-JOSE, PE
EXISTI
TO BE
FROM
OF 4
('_l� ROOF PLAN
��AAJ-5 SCALE: 1/4 91 = 1 9-099
OUTLINE OF BUILDING BELOW
EXISTING SHINGLE ROOF SYSTEM
GENERAL ROOF NOTES:-
1 . VTR AND EXHAUST PENETRATIONS SHALL BE A MINIMUM OF 4'-0" FROM EDGE OF ROOF, TYP.
2. PROVIDE ALL COMPONENTS FOR A COMPLETE ROOF SYSTEM AND FLASHING, EVEN IF NOT
SPECIFICALLY NOTED TO PROVIDE COMPLETE WEATHER —TIGHT CONDITION.
3. PROVIDE ARCHITECTURAL LAMINATED ASPHALT SHINGLES WITH SELF SEALING GRANULE SURFACE.
4. PROVIDE #30 ROOFING UNDERLAYMENT — WATER REPELLENT BREATHER TYPE CELLULOSE FIBER
BUILDING PAPER.
5. PROVIDE A LEAK BARRIER PER MANUFACTURER REQUIREMENT AT VALLEY, AROUND DORMERS, SIDE
WALLS AND PLUMBING VENTS.
6. INSTALL A PRE—CUT STRIP PRODUCT (ONLY THOSE WITH FACTORY APPLIED ADHESIVE) AT THE EAVES
AND RAKES AND YOU MUST INSTALLED EACH SHINGLE USING 6 NAILS. YOU MUST CEMENT THE
STARTER STRIP IN AND NAIL ALONG THE RAKE.
7. PROVIDE RIDGE VENTS THAT CORRESPOND TO THE SHINGLE PRODUCT YOU ARE INSTALLING.
8. PROVIDE PERFORATED ALUMINUM CONTINUOUS SOFFIT VENTS.
9. PROVIDE METAL DRIP EDGE AND EAVES AND RAKE EDGES.
10. PROVIDE MINIMUM 25 YEARS WARRANTY FOR SHINGLES AND ACCESSORIES.
11. GUTTER SHALL BE SLOPED 1/16" PER FOOT, GUTTER TO DOWNSPOUT. PROVIDE 4" K—STYLE
ALUMINUM PRE —FINISHED GUTTERS. ANCHOR DOWNSPOUTS AT TOP, MIDDLE AND BOTTOM, MAX. 4'-0-.
r
z
cis
a�
lot
z
Ln 9
r0
2 zz
�_Il ()
P41-4
WA C/)
P4 w
lmzn
6 n
z Z
Ic
r Issued for: Date:
El PRELIMINARY
El PRICING
0 BIDDING
0 PERMIT 12/27/2019
REVISION #1
Ln
p"
Ln
Seal
License Number: 73539
M
LDrawnby: FRANKDE-JOSE,PE
1 4
OVERHANG OVERHANG
LDrawnby: FRANKDE-JOSE,PE
1 4
OVERHANG OVERHANG
ROOF SHEATHING FASTENING SCHEDULE a,b,c,d,e
8d Common (0,131 x 2-1/2 inches) or Ring —Shank (0.135 X 2-1/2 inches)
(Except Where Noted) for Exposure 8, Enclosed Buildings, Roof Framing Spaced 24 inches o.c.
or Less
Roof Fastening Zone
Overhang
Wind
Main Sheathin g— to— Gable
(eaves)
Velocity
Roof End —Wall Framingg
(3—Second
Panel
1 2 3 2 3
2 3
Gust)
Location
Fastening Schedule (inches on
center)
Supported Panel
6 6 6
6 6
150 mph f,g
end and edges
3h
Panel field 6 4 3
f,g Supported Panel 6 6 6
120 mph end and edges 3
Panel field 12 6 4
4 3
6 6
6 4
C.
Specific gravity (G) of lumber and panels
shall be
0.42 or greater.
b.
For Exposure B and a 2—foot overhang.
C.
For median roof height 35 feet or less.
Cl.
Gable wall height of 8 feet or less from
top floor
ceiling to roof peak.
e.
Provide adequate uplift hardware at truss —to —wall
connections. Such connections
are
beyond the scope of this publication.
f,
When wind speed is 110 mph or greater
and when
median roof height is between
25 and 35 feet, use 8d ring shank nails
(0.135 x
2-1/2 inches)within 48 inches of
gable end walls. (IRC Table R602.3, footnote f)
g.
When wind speed is 100 mph or greater,
block panel edges perpendicular to
gable
—end —wall framing members in the first
two bays
of framing. Blocking shall be
spaced a maximum of 4 feet o.c. (Wood
Frame Construction Manual, Section 3.5.5)
h.
10d ring —shank nails (0.148x 3 inches).
i.
Blocking not required.
ROOF FASTENING ZONES FOR WIND UPLIFT
Zones 1,2 and 3 shown below indicate areas of the roof that may have different fastening
requirements.
CABLE END WALL
FIT.Al a 10 4 ME
3 OVERHANG --� \ / 3 OVERHANG
2
I .................. OVERF .. ....
I A N G.
2 .......
.... OVERHANG
---------
...... .......
3 -1 2 3
—
....... :4 77.
3 2
......
........ r
1 1%
.....
..... ......
............
......
..... ......
............
.....
.....
......
......
............
.........
... .....
......
..... 0
t-111-111
GABLE
ROOF
......
............
2`1 1 2
.....
>
__j
_j
<
...... ............
f ......
..... j ......
......
..... . ....
.....
.. ......
. .....
...... ......
............
............
................
2 .. .....
-.-.-3 3.
2
..........
. 7 .......
2 ......
.. 77T — — — — — — — — T77 ........
....... 2
...
... .......
OVERHANG .........
OVERHANG ...
3 OVERHANG
\WALL
3 OVERHANG
LINE
GABLE END WALL
Distance a=4 ft. in most cases (10% of least building width or 0.4 times building height,
whichever is smaller, but not less than either 4% of least building width or 3 ft.)
ROOF DIAPHRAM NAILING SCHEDULE (GABLES
EXISTING EXTERIOR WALL AND TRUSS FRAMING —`
TO BE REVIEWED TO ENSURE THERE IS NO DAMAGE
FROM VEHICLE ACCI DENT/I M PACT. NOTIFY ENGINEER
OF ANY DAMAGE MATERIALS FOUND.
SIMPSON VTCR SLOPE CONNECTORS
PRE—ENGINEERED TRUSSES AT
24" D.C. AT SHADED AREA
NEW PRE—ENGINEERED WOOD
TRUSSES AT 24" O.C., TYP.
k M$e
�m .
SCALE: 1/4 )3 = V-011
3:12 SLOPE.
-7
L_j --- I --- I --- I ---
GABLE END 2X4 -` OUTRIGGERS
FRAMING AT 16" O.C. AT 24" O.C.
UPLIFT CONNECTION CROSS REFERENCE - SIMPSON STRONG TIE
CONNECTOR
CAPACITY
FASTENERS
FLORIDA
APPROVAL #
LOCATION TO BE USED
H16S
1370
TRUSS:2-10dx 1 1/2"; PLATE: 10-10dx 1 1/2"
FL1 1470.2
WOOD WALL TO WOOD TRUSSES
H16S
1370
1/4% 1 3/4" TITEN OR TITEN 2 SCREWS
FL1 1470.2
CONCRETE WALL TO WOOD TRUSS
HTS24
1310
20-10d
FL1 0456.5
WOOD TRUSSES TO DBL TOP PLATE
MSTAM36
1870
WOOD 13-10d; CONCRETE 8-1/4"x 1 3/4" TITEN 2
MASONRY 8-1/4"x 2 1/4" TITEN OR TITEN 2
FL1 1473.11
CMU OR CONCRETE WALL TO
2ND FLOOR WOOD JOIST
Spi
555
STUD: 6-10d; PLATE: 4-10d
FL1 0456.5
STUD TO SILL PLATE — 2ND FL
SP2
1010
STUD: 6-10d; PLATE: 6-10d
FL1 0456.5
STUD TO DBL TOP PLATE — 2ND FL
NOTE:
IF OWNER OR CONTRACTOR WANTS TO USE A DIFFERENT SIMPSON STRONG TIE, CONTRACTOR
SHALL SUBMIT COPY OF PRODUCT APPROVAL DOCUMENTATION TO BUILDING DEPARTMENT.
3:12 SLOPE
CD
Q!:
LLJ
1'— 4"
OVERHANG
EXISTING SHINGLE ROOF SYSTEM
TO REMAIN
0
LEGEND
2X6 SINGLE MEMBER HEADER
AT 2ND FLOOR WINDOW OPENINGS
CONVENTIONAL 2X6 FRAMING
0 24" O.C. OR PRE-ENG TRUSSES
AT SHADED AREA
8"X16" CONCRETE TIE BEAM.1
TOP OF BEAM IS 11'-4" A.F.W
Iffe][11111:1110
1. FRAMING PLAN IS DIAGRAMMATIC IN NATURE
AND IS PROVIDED FOR ILLUSTRATION
PURPOSES ONLY. TRUSS MANUFACTURER TO
PROVIDE A SEPARATE LAYOUT AND TRUSS
DESIGN, SIGNED AND SEALED BY A FLORIDA
LICENSE ENGINEER.
2. ENGINEER RESERVES THE RIGHT TO MODIFY
DRAWING UPON REVIEW OF TRUSS ENGINEER
SHOP DRAWINGS REVIEW, TO ENSURE LOAD
PATH IS PROPERLY ESTABLISHED.
z
Ln
0
04
04 C/)
W4 W
z
LIMZ
PA
Issued for: Date:
El PRELIMINARY
[I PRICING
El BIDDING
N PERMIT 12/27/2019
VIS
ION #1
Ln
c
LM
P"
Ln P=
Ln P=
Seal
License Number: 73539
A=6
Q rown by: FRANK DE-JOSE, PE )
Q rown by: FRANK DE-JOSE, PE )
00
3-TAB ASPHALT SHINGLES,
OVER #30 FELT UNDERLAYMENT,
lX6 FASCIA BOARD OVER 5/8" PLYWOOD SHEATHING
Uj
C-D
r-
-1
4A'
I
1
-T
LL-
V)
N
NEW 8" CMU LOW WALL -j '-- NEW STUCCO FINISH WITH BRICK PATTERN
60, OVER NEW 8" CMU WALL TO MATCH EXISTING
NEW GUTTER
FOOTING
('-3� BUILDING SECTION.
��A-J7 SCALE: 1/2 9) = i I-C
NEW SCREENING AT
WOOD FRAMING OPENING
12
]3
EXISTING SHINGLE ROOF
SYSTEM TO REMAIN
EXISTING EXTERIOR FINISH
TO REMAIN
TYPICAL SIDE ELEVATION
SCALE: 1/4 99 - 1 5 -0 19
REVIEW AREA WITH CRACKS IN WALL,
BOND BEAM AND BRICK VENEER TO
ENSURE NO DAMAGE TO MAIN HOME
FROM VEHICLE IMPACT --�
12
NEW ALUMINUM SCREEN DOOR
FRONT ELEVATION.
�AJ-7 SCALE: 1/4 11 = 9 - 19
1 0
NEW FIBER CEMENT SIDING
OVER BUILDING PAPER OVER
1/2" EXT. SHEATHING
lX6 FASCIA BOARD
" NEW 8" CMU LOW WALL
NEW SCREENING AT
WOOD FRAMING OPENING
NEW STUCCO FINISH WITH BRICK PATTERN
OVER NEW 8" CMU WALL TO MATCH EXISTING
EXISTING SHINGLE ROOF
SYSTEM TO REMAIN
EXISTING STUCCO FINISH
WITH BRICK PATTERN
z
@)
Z
ci
Ln
00
2zz
1-1 Q
z C)
LZ Z
LM w< I
Issued for:
Date:
El PRELIMINARY
El PRICING
El BIDDING
0 PERMIT
12/27/2019
Ei REVISION#1
rSeal
Ln
4=)
4)
4)
4=1
rim
LM
LM
In >1
License Number: 73539
A=7
LDrownby: FRANKDE-JOSE,PE
A
C
DRIP EDGE
ALUMINUM GUTTER
AL 71-411 (A.F.F.)
'-r TOPOFCMU
1X6 FASCIA BOARD
PREFORATED ALUMINUM
SOFFIT
DOWNSPOUT BEYOND
3-TAB ASPHALT SHINGLES�
OVER J30 FELT UNDERLAYMENT,
OVER 5/8' PLYWOOD SHEATHING
1X2 WOOD FURRING STRIPS
V-4-
OVERHANG
1 X 4 WOOD TRIM
PATIO SCREEN FABRIC - (MEDIUM DUTY FIBERGLASS CHARCOAL)
TO BE PLACED AT UPPER PORTION OF SCREEN WALL
1 X 4 WOOD TRIM
PRECAST SILL
9" CMU WAH
VVERT. REINF. 0 MAX
4 -0" O.C. IN CONCRETE
FILLED CELLS
0-0" FIN. FLOOR (F.F.)
GRADE LEVEL
2,000 F M.N.
2-
PRE-ENGINEERED WOOD
TRUSSES AT 24" D.C.
12
3 1
HURRICANE CUP
AT EACH TRUSS
2X P.T. WOOD PLATE
5/8" M04STURE RESISTANT
GYPSUM BOARD
1X4 WOOD FURRING STRIPS
SPACED AT 24" D.C.
3/4' QUARTER ROUND
TRIM MOULDING
1/2' ANCHOR BOLT
J5 BAR
P.T. 2 X 6 WOOD
1/2' QUARTER ROUND TRIM
MOULDING
ALUM. SCREEN FRAME WITH SPLINE CHANNEL
ATTACHED TO 1X2 WOOD WTH COUNTER SINK
SCREWS (#IOX1-) SPACE AT 12' D.C.
I t
ALUM. SCREEN FRAME WTH SPLINE CHANNEI
ATTACHED TO 1X2 WOOD WTH COUNTER SINK
SCREWS (#lOX1') SPACE AT 12- D.C.
1/2' QUARTER ROUND TRIM
MOULDING
P.T. 2 X 6 SILL PLATE
14
C4
(2) #5 BARS
V-0.
(`1�TYPICAL WALL SECTION
SCALE: 1 1/2" = is-011
..... .... ...
e THICK CONCRETE SLAB WTH
6X6 1.4 - 1.4 WWM OVER 6 MIL
VISQUEEN ON CLEAN COMPACTED SOIL
F
/`�2RIDGE VENT DETAIL
�A-8) SCALE: 3 1 1-091
I �
2"X4" Vertical Brace
added 'to every Vertical
over 4 in length. Brace
to be minimum 80% length
of Vertical Truss Member.
Fasten Brace to Vertical
w/16d Common Nails 12" o.c.
Bottom Chord of Truss
fastened to Sill Plate
w/16d common Nails
@ 12"o.c.
1/2"0 Anchor Bolt
w/2" Flat Washer
w/min. Embedment
4 into Bond Beam
@ 4' o.c. (Typical)
ATHINO
End Truss 2"X8" P.T. SYP Sill Plate fastened to
Bond Beam w/l/2"O anchor
bolts @ 4' o.c.
2"X4" Nailer
Typical Interior Trusses
Min. 2"X4" Lateral Bracing Continuous
per Truss Manuf. specs.
1/2" Vinyl or Gypsum Ceiling Board
TTPICAL GABLE- E-11 D ffALL DETAIL
SCALE: ISIT25
2"X4" Vertical Brace
added to every Vertical
over 4' in length. Brace
to be minimum 80% length
of Vertical Truss Member.
Fasten Brace to Vertical
w/16d Common Nails 12" o.c.
2"X4" Nailer —
Lateral Bracing installed per
Pre—engineered Truss Plans
Typical Interior Truss
/2" S.R. Gypsum Ceiling Board
Bottom Chord of Truss
fastened to wall top plate
w/16d common Nails
@ 12"o.c.
End Wall Studs
Simpson LST18 (or equal)
fastened w/ 14-10d Nails.
7-RAME WALL DETAIL
SCALE: NTS
j
z
CIA Z
2
qt� Ln
EIIIIIIIIIIIIIIIIII
r2z z
F-4 0
z
z Z
Issued for:
Date:
0 PRELIMINARY
El PRICING
El BIDDING
N PERMIT
12/27/2019
El REVISION #1
4
01
00 N
Ln
mom
Ln
-*.jg
License Number: 73539
A=8
mwn by: FRANK DE-JOSE, PE
c
4
ki