Loading...
HomeMy WebLinkAbout5629 Rhonda Ct (2)LOT 74 Lc 7 SITE 64L� NORTH/ PLAN_ LU N w „ Y SCALE: )1 10' 9� 'W tu Z Fm o^ N Z„ J aC EXISTING COVERED LANAI RENOVATION w & GARAGE DOOR GONVERSION to V-1inLU LEGAL DESCRIPTION: LOT 11, 5UN5ET E5TATE5-2, according to the plat thereof, as recorded in Plat Book 16, Pages 5-4, of the Public Records of Pasco County, Florida DRAINAGE NOTE: THE EXISTING ROOF OVER NHIGH ALL STRUCTURAL RENOVATIONS ARE TO OCCUR, YNILL REMAIN UNCHANGED PERIPHERALLY AND DIMEN51ONALLY THEREFORE, NO NEN ADDITIONAL RUN-OFF HILL EXPECTED TO IMPACT SURROUNDING PROPERTIES. SCOPE OF NORK: STRUCTURAL RENOVATIONS OF THE REAR COVERED LANAI'S, V4' HICH HILL INCLUDE NEY�I NINDONS AND Ar NEN DOOR, FRAMING Y�1ALLS IN THE COVERED SOUTH LANAI KITH Ar NEN CONCRETE SLAB. THE GARAGE DOOR 15 GOING TO BE ELIMINATED AND Ar Y'IINDON kNILL BE FRAMED IN THE CENTER OF THE Y'IAtLL.. \LL WORK SHALL COMPLY WITH PREVAILWC= ;,ODES FtARIDA BUILDING CODE. NATIONAL ELECTRIC CODE, AND THE CITY OF ZEPHYRHILLS ORDINANCES V\EW gg HYR� 2022 R AY 0 x \\ AsR LICENSE No.47431,- STATE OF ♦ ,� FLORIDA �SS�GNALE������� /il/11I0 This item has been electronically signed and sealed by Dr. Ram A. Goel using a Digital Signature and date. Printed copies of this document are not considered signed and sealed and signature must be verified on any electronic copies Digitally signed by Ram Goel DN E=SoneyfmllcLyahoo com, CN=Ram Goel, Ram Goel OUSoneylNEERING. MLLLC L=Tampa, S=Florida, C=US Date. 2022.08.11 10.13.49-04'00' I HEREBY CERTIFY THAT I HAVE REVIEWED AND SUPERVISED THE ATTACHED DE516N AND FOUND IT TO BE IN COMPLIANCE WITH THE 2020 F_B_G. RESIDENTIAL 7TH EDITION DR. RAM A. GOEL, P.E.(#47431) 50NEY FM LLC, GA # 9746 GORY LAKE PROFE55IONAL CENTER 10329 GROSS CREEK BLVD., SUITE P TAMPA, FL 33647 Ph: 813-293-1868 51TE EXISTING/DEMOLITION FLOOR PLAN WALL LEGEND: EXISTING 8" EXTERIOR GONG. BLOCK WALL EXISTING 4" WOOF FRAME DEMOLITION AREAS: NOTE: ALL AREAS COVERED BY THE ABOVE HATCH ARE AREAS TO BE DEMOLISHED, REPLACED OR RENOVATED. EXISTING GARAGE DOOR FRONT ELEVATION DEMOLITION AREAS: NOTE: ALL AREAS COVERED BY THE ABOVE HATCH ARE AREAS TO BE DEMOLISHED, REPLACED OR RENOVATED. GEILIN& 2x4 TOP PLATE CONNECTED "5P2" (FLA # 10456.42) OR EQ 2x4 HEADER NEW 1/2" DRYYVALUPLASTER - BOTH SIDES .o 2x4 STUDS 16" O.G. 2x4 BASE PLATE CONNECTED W/ SIMP50N "SP1" (FLA # 104 W/ SIMPSON DIVALENT TOP PLATES (FLA # 10456.42) 56 SIMPSON "SP1" BOTTOM PLATES (FLA # 10456.41) .4 FLOOR 5Y5TEM i TYFIGAL I P TftNIUK FRAME MALL 5ECTION SCALE .. NOTE: SCOPE OF WORK WILL INCLUDE RENOVATION OF REAR LANAI'S, WHICH WILL INCLUDE NEW 1NINDOWS AND A NEW DOOR. AL50 NEW WOODFRAME WALLS ON THE SOUTH LANAI. THE EXISTING ROOF OVER BOTH AREAS WILL REMAIN INTACT. THE GARAGE DOOR WILL BE ELIMINATED AND A 3648 WINDOW WILL BE FRAMED IN CENTERED IN THAT AREA. THERE WILL BE NO ADDITIONAL. 50. FT. ADDED TO THE PROPERTY. CONTRACTOR TO REMOVE EXISTING GARAGE DOOR, REPLACE WITH 1-3645 WINDOW AND FRAME IN AROUND NEW WINDOW WITH 2x8's. TAPGON INTO EXISTING LINTEL ABOVE NEW WINDOW. APPLY STUCCO TO MATCH EXISTING HOUSE OVER NEW WOODFRAME WALL. PATCH INTERIOR 5HEETROCK. PROPOSED WINDOW FRONT ELEVATION PROPOSED FLOOR PLAN WALL LEGEND: PROPOSED EXTERIOR WOODFRAME WALL PROP05ED INTERIOR WOODFRAME WALL EXTERIOR WOODFRAME WALL EXISTING 8" EXTERIOR GONG. BLOCK WALL NOTE: SUNROOM "A" HAS, EXISTING MECHANICAL. 5UNROOM "B"WILL NOT BE CONDITIONED. DEN AREA WILL NOT BE CONDTIONED. 1111 \M0A. GO ���/ LICENSE No i STATE OF �� 'i FLORIDA I lilt% This item has been electronically signed and sealed by Dr. Ram A. Goel using a Digital Signature and date. Printed copies of this document are not considered signed and sealed and signature must be verified on any electronic copies Digita lly sed by Ram GoaOlt E=S3OneyfmllolQydtoo.com, Rare Goers �NURING, O-Soney FM LLG, L=Tampa, S=FWida, C=US Date: 2022.00.11 10:13:35-04100' I HEREBY CERTIFY THAT i HAVE REVIEWED AND SUPERVISED THE ATTACHED DE516N AND FOUND IT TO BE IN COMPLIANCE WITH THE 2020 F.B.G. RESIDENTIAL TTH EDITION DR. RAM A. GOEL, P.E.N41431) SONEY FM LLG, GA # 9i46 GORY LAKE PROFF-591ONAL CENTER 10329 CROSS CREEK BLVD., 5UITE P TAMPA, FL 33641 Ph: 813-293-1868 lU < n lti `_r Q r- d OC a1 Z z z z� � oQ zIn WE< cmn O �jN 7 �a Vo�; zJWE z LLI IL Q Q LU umi ul } lu V .nIU V I zQ � d O X(Y- i LU IL -� 0L A-1 PROPOBED ELECTRICAL PLAN ELECTRICAL LEGEND : ELECTRICAL WIRING LIGHT FIXTURE ARC, -FAULT CIRCUIT INTERRUPTER DUPLEX OUTLET WALL SWITCH NOTE: ELECTRICAL LAYOUT 15 A 5CHEMATIG ONLY. GON5ULT LICENSED ELECTRICAL CONTRACTOR, GENERAL CONTRACTOR AND/OR OWNER BEFORE INSTALLING ANY ELECTRICAL FIXTURE MAKE NEW ELECTRICAL CONNECTIONS TO EXISTING MAIN PANEL AT EXI5TINC SPARE CIRCUITS AND VERIFY ALL RESULTANT LOAD5. NEC, 2017 210.12 ALL 120-VOLT, SINGLE PHASE,15- AND 20 AMPERE BRANCH CIRCUITS 5UPPLYING OUTLETS INSTALLED IN DWELLING UNIT FAMILY, DINING, LIVING, BEDROOMS, LIBRARIES, PARLOURS, DENS, SUNROOMS, CLOSETS, RECREATION RMS., CLOSET, HALL104AY5 OR SIMILAR ROOMS OR AREAS SHALL BE PROTECTED BY A LISTED (AFCI)- ARC-FAULT CIRCUIT INTERRUPTER NOTE: SUNROOM "A" HAS EXISTING MECHANICAL. SUNROOM "B" WILL NOT BE CONDITIONED. DEN AREA WILL NOT BE CONDTIONED. GENERAL NOTE5: ALL WORK SHALL CONFORM WITH THE LATEST ADOPTED EDITION OF THE FLORIDA BUILDING GORE, MECHANICAL CODE, PLUMBING CODE, THE NATIONAL ELECTRICAL CODE AND ALL APPLICABLE CODES AND REGULATIONS, LOCAL, CITY, STATE, FEDERAL, SAFETY BOARD OF FIRE UNDERWRITERS AND FIRE DEPARTMENT. WORKMANSHIP SHALL BE EQUAL TO THE BEST TRADE PRACTICES ALL INSTALLATIONS OF MANUFACTURE'5 SPECIFICATIONS SHALL BE IN EXACT COMPLIANCE WITH MANUFACTURE'S PRINTED INSTRUCTIONS. CONTRACTOR AND/OR OWNER SHALL VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS BEFORE ANY PHASE OF CONSTRUCTION 15 TO COMMENCE. CONTRACTOR AND/OR OWNER SHALL COORDINATE ALL WORK BETWEEN SITE, BUILDING, ELECTRICAL, MECHANICAL AND PLUMBING BEFORE EACH PHASE OF CONSTRUCTION BEGINS. DO NOT 5CALE PLANS. STANDARD 90 HOOK GONT. 12" WIDE x 16" DEEP _ MONOLITHIC SLAB EDGE/FTG. W/ (2) #5's CONT. LAP SPLICES MIN. 24" 8 TIE w / WIRE. TYP. @ PERIMETER 0" LAP SPLICE 10' 4"THICK GONG. SLAB w / bxb 10/10 W.W.F OR FIBERME5H REINF. ON b MIL. POLYETHYLENE VAPOR BARRIER ON GLEAN COMPACTED SAND FILL w / SOIL POISONING (TYP.) NEW 5UNROOM FIN. FL. SLAB ELEV = 85.25' 5LA9 To MAl" EXI5TIN& EXISTING FIN. FL. SLAB ELEV = 85.25' NOTE: 2' CONTRACTOR TO SAWGUT UNDER EXISTING SLAB TO ADD 12x16 FOOTER TO THI5 AREA. _A_ AP UP EXIST . 5 . SLAB TO MATCH HOUSE FF 3"t NEW SUNROOM FIN. F� SLAB ELEV = 85.25' BOND NEW FTC. TO EXISTING FTC. BY DOWELING (2) NEW #5's REINF. STEEL INTO EXIST. FTC. MIN. 7" AND SET w / EPDXY GROUT (TYP. EXISTING 5LAB AND FOOTER TO REMAIN 4X12 GONG. STOOP ELEV = 85 WHERE NEW SLAB MEET EXIST. SLAB ALL THE WAY AROUND ... TIE NEW SLAB. REINF. STEEL INTO EXISTING. BY DOWELING NEW (1)#5 @ 5' 0.6 INTO EXIST. FTC. MIN. 7" AND SET W/ EPDXY GROUT (TYP.) / 3. 4' PROP05ED FOUNDATION PLAN CONCRETE: 3.1 CONCRETE COMPRESSIVE STRENGTH AT 28 DAYS: 3000 P51 (NORMAL WEIGHT). 3.2 REINFORCING BARS: A5TM A615 (GRADE 40). 3.3 WELDED WIRE FABRIC, (WWF): A5TM A185. 5.4 DETAIL REINFORCEMENT IN ACCORDANCE WITH AGI 315. 3.5 CONCRETE COVERAGE OF REINFORCEMENT: FOOTINC75 3" BOTTOM AND SIDES. 3.6 EARTH SUPPORTED SLABS: (INCLUDING EXTERIOR WALK AND DRIVE 5LA55) 3 %s" THICK, REINFORCED WITH 6X6 MESH MAY BE USED IN LIEU OF WWF AT CONTRACTOR'S OPTION. 3.7 CONCRETING OPERATORS SHALL COMPLY WITH AGI STANDARDS. 3.8 LAP SPLICE SHALL BE AS FOLLOW5: #7 BAR 35", #b BAR 30", #5 BAR 25", #4 BAR 20", #3 BAR 15". 0\��p`►t'A. GO LICENSE No 4743 -Q i 7�, STATE OF FLORIDA This Item has been electronically signed and sealed by Dr. Ram A. Goel using a Digital Signature and date. Printed copies of this document are not considered signed and sealed and signature must be verified on any electronic copies Digitally signed by Ram Goal DN: E-SoneykiW@ tehoo.com, Ram Goal OUNEm Goal, OI�NGINEERING, O■Sonay FM LLC, L"Tampa, SAFINkle, C=US Date: 2022.0&11 10:13:20-04'00' I HEREBY CERTIFY THAT I HAVE REVIEWED AND SUPERVISED THE ATTACHED DE516N AND FOUND IT TO BE IN COMPLIANCE WITH THE 2020 F.B.G. RESIDENTIAL 7TH EDITION DR. RAM A. GOEL, P.E.(#47431) SONEY FM LLC, GA # 9746 GORY LAKE PROFESSIONAL CENTER 10329 CROSS CREEK BLVD., SUITE P TAM PA, FL 33647 Ph: 613-293-1865 LU J < w kn :�t n < Q Cw ul z ztu w OQ zW, _ m tf) WE -j VQ JU z O wm In In z_ O z O lti LU } 7— O V 0 O Q w N Ln �m o� U_ o O� Q x OW QN w< Q 3 z Q O wWE � } N O%Z z Ln LU z :5 WE w } O V to X w n A-2 APPLY STUCCO TO MATCH OVER WOODFRAME NEW 8' WALLS UNDER EXIST. ROOF FL - APPLY STUCCO TO MATCH'. OVER WOOOFRAME WALL ------------------------------ EAST ELEVATION SCALE 1 /4" = 1' 9 SOUTH ELEVATION NE 150METRIC ELEVATION SCALE 1 /4" = 1' WINDOWS 8 DOORS NOTE: ALL WINDOY45 & DOORS INSTALLED ON THIS PROJECT MUST MEET 150 M.P.H WIND RESISTANCE 5TANDARD5 PER R301.2.1 2020 F.B.G. RESIDENTIAL ITH EDITION SECTION NOTE: SCOPE OF WORK WILL INCLUDE RENOVATION OF REAR LANAI'S, WHICH WILL INCLUDE NEW WINDOWS AND A NEW DOOR. ALSO NEW WOODFRAME WALLS ON THE SOUTH LANAI. THE EXISTING ROOF OVER BOTH AREAS WILL REMAIN INTACT. THE GARAGE DOOR WILL BE ELIMINATED AND A 3648 WINDOW WILL BE FRAMED IN CENTERED IN THAT AREA. THERE WILL BE NO ADDITIONAL 50. FT. ADDED TO THE PROPERTY. NORTH ELEVATION 56ArLE 1 /4" = 1' EXISTING F.G 5HINGLES OVER #15 FELT OVER 1/2" PLYYVOOD ---� SHEATHING OVER FRAMED TRUSS ® 24" O.G. EXISTING METAL DRIP EDGE EXISTING 2" x 8" FASCIA BOARD EXISTTNG GONT.VENTED ALUM. SOFFIT MATCH EXIST. EXTERIOR FINISH OVER #15 FELT OVER 1 /20 PLYWOOD — SHEATHING 2"x P.T. PLATE M 1/2" }ANCHORAGE BOLTS ® 21" 0.( (TYP. ) T- * , * * * MIN. V-0' BELOW FINISH GRADE 125c 16" MONO. GONG. FOOTING W/ 2-#5 REBAR CONT. NALL SECTION SCALE N.T.5 R-1 q INSUL. OR BLOWN 5/8" DRYWALL CEILING ONLY DBL. 2N TOP PLATE DBL.2"x HEADER ALUM. SINGLE HUNG WINDOW WINDOW STOOL —1/2" DRYWALL OVER 2"x STUDS @ 16"O.C. OVER R-11 IN5UL. SIMPSON "51*1" BOTH TOP AND BOTTOM PLATES 4" GONG. SLAB, MIN COMPRESSIVE STRENGH OF 3,000 P.S.1 0 28 DAYS "b x b 10 x 10 W.W.M. OR FIBER MESH OVER b MIL. VAPOR BARRIER ON TERMITE TREATED AND COMPACTED GLEAN FILL. `♦�` LICENSE No 4743 06, i STATE OF e� FLORIDA EXIST. 6' WALLS UNDER EXIST. ROOF Digitally signed by Ftam Goal DN: E►$EI11ey1rMiC,�yalloo.com, Ram Goel mG , G OEOEI OwSa ey FM LLC, L=Tampa, S=Flo", C=US Date: 2022.06;11 10:13:04-04'& I HEREBY CERTIFY THAT I HAVE REVIEWED AND SUPERV15ED THE ATTACHED DESIGN AND FOUND IT TO BE IN COMPLIANCE WITH THE 2020 F.B.C. RESIDENTIAL TTH EDITION This item has been electronically signed and sealed by Dr. Ram A. Goel using a Digital Signature and date. Printed copies of this document are not considered signed and DR. RAM A. GOEL, P.E.(#4-1431) sealed and signature must be verified on any SONEY FM LLC, CA # g746 electronic copies CORY LAKE PROFESSIONAL CENTER 103241 CROSS CREEK BLVD., SUITE P TAMPA, FL 3364'1 Ph: 813-2413-1868 w -1 wfj v��1�� N d) A j •- d U- z J F lu .x V z kn O a z m J d3 v �QCID x o � 0 %D = x w �- W LUCn In LU m z7W _ at < Q OL } IL wp z U-t a. A- 3 INTERIOR HEADER 50HEOULE OPENING 51ZE HEADER SIZE UP TO3'-4" 2-211x6" 3'-5" TO 5'-4" 2 - 2" X 8" 5'-5" TO S'-6" 2 - 2" X 10" 8'-1" TO 12'-6" 2-2 so x 12" REGU I RED AT LOAD BEARING Y*4ALL 16d NAILS ®- 16" O/C TYP. 0 F°°R Ni C /- SINGLE 2to0" CRIPPLE STUD TYPICAL 2--SiMPSON LSTA18 * UNLESS NOTED OTHERWISE 2-ROWS 16d NAILS STAGGERED 0 16" O/C EACH FACE OR 3-ROWS 16d NAILS STAGGERED 9 16" O/C FOR 2"00" OR GREATER HEADER DOUBLE HEADER W/ 1/2" FLITCH PLATE FILLING AND BLOCKING AS REQUIRED FASTENED TO HEADER W/ (2) 16d 0 16° O/C UNLESS NOTED OTHERWISE 2"x4" STUDS TYP. SiMPSON H TT16 W1 5/8"0 HILTI KWIK BOLT If ANCHOR W/ 6" EMBEDMENT U.N.O. P.T. SOT. PLATE ' UPLIFT CONNECTIONS REQUIRED AT LOAD BEARING WALLS LOAD BEARING/EXTERIOR UJALL. HEADER DETAIL. NAILING SCHEDULE Connection Joist to band joist, face nail Joist to sill or girder, toe nail Bridging to joist, toe nail each end Ledger strip Sole plate to joist or blocking, face nail Top or sole plate to stud, end nail Stud to sole plate, toe nail Double studs, face nail Double top plates, face nail Continuous header, two pieces Ceiling joists to plate, toe nail Ceiling joists, laps over partitions, face nail Ceiling joists to parallel rafters, face nail Rafter to plate, toe nail Built up corner studs Built-up girders and beams, of three members Fastener Number of Spacing 16d common 3 8d common 3 8d common 2 16d common 3 at each ,joist 16d common 16" o.c. 16d common 2 8d common 4 10d common 24" o.c. 10d common 16" O.C. 16d common 16"o.c. along each edge 8d common 3 - 3-16 or 4-10d common 8d common 3 16d common 24" o.c. 10d common 32" o.c. at top and bottom and Wood Structural Panel/Subflooring 19/32"-3/4" 10d common or 6" o.c. edges and 10d hot dipped galy. box nails 12" o"c. intermediate Wood Structural Panel/Roof & Wall Sheathing 8d common or 6" o.c. edges and 8d hot dipped galv. box nails 6" o.c. intermediate and 4" o.c. gable truss Gypsum Wallboard 13/8" drywall nail 7" o.c. on ceilings 8" o.c. on walls 1/2" 1 V2" drywall nail 7" o.c. on ceilings 5/8" 8" o.c. on walls 3 tab asphalt roofing shingles 1. `/4" min. 6 fasteners per shingle 11 ga. Galy. nails with min. 3/8" diameter head ALTERNATIVE ANCHORAGE METHOD �1 I + I L-J SI MIPSON -HD2A7 W/ 5/8" !d BOLT ANCHOR W / B" EMBEDMENT BELOW (TYP.) EACH SIDE EXTERIOR FINISH 7MG" EXT. O.S.B. • (3) 2"'x_ JAMB 1"x TRIM 1 "x_ DOOR STOP 1 /2" GYP. BOARD - --I 2"x 8" P.T. WOOD JAMB DOOR AND CONNCEI PER GARAGE DOOR MANUFACTURER FRAME GARAGE DOOR JAMB DETAIL PANEL (SHEATHIN ) ATTACHMENT SCHEDULE 4'-0" TA 'A' TERNATE NAIL SPACING 'B' ER TABLE AT LEFT 0 e 8 toe o 0 4' x 8' SHEET OF PLYWOOD '� SHEATHIN RF_FER TO OTHER NOTES AT WALL SECTION OR • • OTHER DETAIL FOR THICKNESS z AND GRACE 1K s oo e e • e56 NAIL SPACING AT INTERMEDIATE o e FRAMING 12" O.C. MAX. . (TYP.) TYP. # N e o W o t- p a • e e I W o 40 e o e 0 o e o o e o 0 NAILS SNGLE ROW NAILS DOUBLE ROW= 1. PLYWOOD PANELS SHALL 0 THE TOP MEMBER AN THE BOTTOM PLATE BY 1 1/2 ' ANO A SINGLE ROW OF FASTENERS SHALL BE PLACED 3/4' PANEL EDGE. 2. PLYWOOD PANELS SHALL THE TOP MEMBER OF THE DOUBLE TOP PLATE PLATE AND THE BOTTOM PLATE BY 1 1/2•. ROWS OF FASTENERS SH BE 1/2' APART WITH A MINIf�IUM EDGE DISTANCE OF 1/2'. CH ROW SHAM HAVE NAILS AT THE SPECIFIED SPACING. SIIEAR ACTES FOR COMMON SH WALL MATERIALS MATERIAL SHEATHING NAIL NAIL SPA SHEAR CAPACBOARD IT NAIL SPACING RE FOR SHEARWALL DESIGN- TABLE 'A' 8dO6"Ac12' Ib0 dt12' 11 adO4"tlC12" 11 1GdO6'At12" ALTERNATE NAIL SP CING AT TOP BTM. PANEL EDGES " 4' 3" 11 6' 3' 6' s• 4' 3" CAPACITY (P10 94 189 0 11 237 N/A 0 tt 0 142 28S 6>i 3T7 566 11 237 4 4 710 t18 35S 59 285 570 SSS WALL FRAMING ALUMINUM WINDOW FRAME 3 - #8 x 1 1 /4" SCREWS PER SIDE (8 TOTAL PER WINDOW) 1 x 2 P.T. BUCK STRIP NAILED TO FRAMING w/ 1Od NAILS 8" O.C. WiNDOW TO FRAME ATTACHMENT DETAIL STRUCTURAL NOTES: SCALE: N.T.S. 1. CODES: 1.1 Current edition of The Florida Building Code Residential 2011 bth Edition. 1.2 Building code requirements for reinforced concrete (AGI 318.06). 1.3 American Society of Givii Engineers minimum design loads for buildings and other structures (A5GE '1.05). 2. SOILS: 2.1 Assumed allowable soil pressure 1,500 P51. 3. CONCRETE: 3.1 Concrete compressive strength at 28 days: 3,000 PSI (Normal weight). 3.2 Reinforcing bars: A5TM A615 (Grade 60). 3.3 Welded wire fabric (WWF): A5TM A185. 3.4 Detail reinforcement in accordance with AGI 315. 3.5 Concrete coverage of reinforcement: Footings 3; bottom and sides. 3.6 Earth supported slabs: (Including exterior walk and driveway slabs) 3 %" thick, reinforced with b x 6 -10 x 10 WWF at mid depth of slab. Fiber -mesh may be used in lieu of WWF at contractor's option. 3.'I Concrete operators shall Comply with AGI standards. 3.8 Lap splice shall be as follows: #5 bar 25"; #4 bar 20" and #3 bar 15". 4. MASONRY: 4.1 Design and construction shall conform to the specification of the National Concrete Masonry Association and AGI 530. 4.2 Minimum masonry unit strength: fm 1,900 P51. 4.3 Mortar shall be type 'S" or "M'. 4.4 All block cells and cavities below grade shall be filled with concrete when stem wall is greater than 24" tall above grade. 5. WOOD: 5.1 Waod structural framing members: #2 Southern Yellow Pine (unless noted otherwise) with an allowable bending stress (fb) per ND5-91 = 1,250 P51 and a modulus of elasticity = 1,600,000 P51. 5.2 All exposed wood or wood in Contact with earth or concrete to be pressure treated. 5.3 Roof sheathing: 1/2" G-D grade plywood (or 15/32" 05B) under 30# felt under 240# fiberglass shingles. 5.4 Untreated wood shall not be in direct contract with Concrete. Seat plates shall be provided at bearing locations without wooden top plates. �nH of spa rw1. (AND #2 5YP 2X4116' OLJ I) II 90TT PLATE� w. snAs SFEAR PANEL - C,ON515T5 OF I/1" GDX PLYWOOD NAILED WITH 8�d GOI��ION NAILS AL50 6LUE YEN �"f 18LE 3' DEC.. ED6Ea E 4" OL. FIELD. ALL OTHER PLYWOOID BETrEEN SHEAR PANELS NAILED WI'M 8d G01'�'�ON NAILS 4" OL. 8" OL. PIf1D. ALL PLYWOOD ED6E5 ON SFIEAR PALL AREAS] SIJF'PIORT� BY 2x4.5HEAR PAt�L. 8JD5 w/ (?) 51MP50N 1,',MST (STRAP) (OR f�l1Al,) NAILED TO EA. STUD (TOP +t BOTTOM). 1 �34Ax�10� T I NGHOR tOR 6' M�nb�l? A1" Al COPN�pS ANp Op�NINGS (Tyr,) TYPICAL. BAR WALL PANEL (W�t SHEAR LEN15TN 15 LEA THAN 2'-0"- UaE ELNERS OR Eg1AL hkaOD 6LUE IN ADDITION TO NAILING) WOOD FRAME WALL MOLDING PRE -HUNG DOOR FRAME SHIM AS NECESSARY 1Qd NAILS (� 16" O.C. 3/4" FURRING NAILED TO FRAMING Wf 10d NAILS _ t�8"O.C. FRAME DOOR ATTACHMENT DETAIL 6" LONG LAG BOLTS MIN. 1/2" OIA. W/WASHERS (2,� #5 EPDXY GROUTED B" INTO EXIST. FTC. ____ EXIST WOODFRAME WALL ('2) 2 x4 " TP !� .. " < / FRAME WALL_TiE--IN DETAIL SCALE N.T. S 1/2 A.B. �4 O.C. A. NOTE: PLATE LENGTHS MUST BE AT LEAST 8'-0" LONG (TYP.) TOP SPLICE -OVER STUD DOUBLE 10d ;� ,r--10d @ 8" O.C. BOTTOM SPLICE OVER STUD TYPICAL TOP BEARING PLATE SPLICE SHEAR Y�lALLS NOTE: ALL FRAME PERIMETER Y�lALLS ARE TO BE CONSIDERED SHEAR Y�IALL SEGMENTS EXCEPT AT DOOR AND Y�tINDOY�t OPENINGS AND YVALL LENGTHS LESS THAN 2'-8" IN LENGTH. NAILING PATTERNS &SPACING @ SHEATHING FOR SHEAR APPLY TO ALL EXTERIOR YVALLS. DOUBLE (5.Y.P) FRAMING r- 2x4 TOP PLATE L9 CRIPPLE STUDS (5•Y.P) HEADER (S.Y.P) 51MP50N "LSTA-30" STRAP OR EQUAL) NAILED TO EA H STUD w / (2) 16d COMMON (EACH STUD) HEADER STUDS S.Y.P NOTE: � SINGLE HEADER STUD FOR OPENINGS b' AND LE55 DOUBLE HEADER STUDS FOR OPENINGS GREATER THAT 8'-0" NO NOTE: (2) 51MPSON HD TYPE HOLD DOWNS REQUIRED AT THE BEGINNING 8 END OF THE SHEAR WALL NEXT TO A MINIMUM DOUBLE STUD TYP. EXTERIOR FRAME OPENING (1st STORY) in In LU WE LICENSE No 4743 ,. i STATE OF �j FLORIDA FULL LENGTHI WAIL STUDS (S.Y.P)iI D'pitaly signed by Ram Goel DN: E"80neyfmite�oo.com, Ram GoeICN+Ram God DU"ENGINEERiNG, O=3onay FM LLC, L■Tampa, S=Fbtlea, C=US Date: 2022.08.1 t 10:12:4e-04'oo' I HEREBY CERTIFY THAT 1 HAVE REVIEWED AND SUPERVISED THE ATTACHED DESIGN AND FOUND IT TO BE IN COMPLIANCE WITH THE 2020 F.B.G. RESIDENTIAL lTH EDITION This item has been electronically signed and sealed by Ram Goel using a Digital Signature and date. Printed Copies of this document are not Considered signed and DR. RAM A. GOEL, P.E.(#4"1431) sealed and signature must be verified on any 50NEY FM LLG, GA # 9i46 electronic copies GORY LAKE PROFESSIONAL CENTER 10329 GR055 CREEK BLVD., SUITE P TAMPA, FL 3364'I Ph: 813-293-1868 5TRUCTURAL DESIGN CRITERIA Areas: Live Loads: Dead Loads: Dwelling Floors: 40 PSF 10 P5F Balconies: b0 P5F 10 PSF Guardrails / Handrails: 200 PSF 10 P5F Balusters: 50 PSF 10 P5F Shingle Roof: 20 P5F 10 P5F Built-up Flat Roof: 20 P5F 10 PSF Tile Roof: 25 P5F 15 P5F GENERAL NOTES: 1. All work shall conform with the latest adopted edition of the Florida Building Code, Mechanical Code, Plumbing Code, The National Electrical Code and all applicable codes and regulations, local, city, state, federal, safety board of fire underwriters and fire department. 2. Workmanship shall be equal to the best trade practices. 3. All Installations of manufacture's specifications shall be in exact compliance with manufacture's printed instructions. 4. Contractor and / or owner shall verify all existing conditions and dimensions before any phase of construction is to commence. 5. Contractor and / or owner shall coordinate all work between site, building electrical, mechanical and plumbing before each phase of construction begins. 6. DO NOT SCALE PLANS. HAZARDOUS LOCATIONS 2406.4 Hazardous Locations. The following shall be considered specific hazardous locations for the purposes of glazing: 1. Glazing in swinging doors except jalousies ( see Section 2406.4.1 ). 2. Glazing in fixed sliding panels of sliding door assemblies and panels in sliding and bi-fold closet door assemblies. 3. Glazing In storm doors. 4. Glazing In all unframed swinging doors. 5. Glazing In doors and enclosures for hot tubs, whirlpools, saunas, steam rooms, bathtubs and showers. Glazing in any part of a building wall enclosing these compartments where the bottom exposed edge of the glazing is less than 60 inches, (1524mm ) above such standing surface. 6. Glazing in an individual fixed or operable panel adjacent to a door where the nearest vertical edge is within a 24-inch ( 610 mm ) arc of either vertical edge of the door in a closed position and where the bottom edge of the glazing is less than 60 inches ( 1524mm ) above the walking surface. Exceptions: 1. Panels where there is Intervening wail or other permanent barter between the door and glazing. 2. Where access through the door is to a closet or storage area 3 feet ( 914 mm ) or less in depth. Glazing in this application shall comply with Section 2406.4, Item 7. 3. Glazing in walls perpendicular to the plan of the door in a closed position, other than the well towards which the door swings when opened, In one and two family dwellings or within dwelling units in Group R-2. 7. Glazing In an Individual fixed or operable panel, other than those locations described in preceding Items 5 and 6, which meets all of the following conditions: T 1. Exposed area of an individual pane greater than 9 sq. ft. (0.84 m2 ); 1.2. Exposed bottom edge less than 18 inches ( 451 mm) above the floor, 1.3. Exposed top edge greater than 36 Inches ( 914 mm) above the floor, and 1.4. One or more walking surface (s) within 36 inches ( 914 mm ) horizontally of the plane of the glazing. Exceptions: Safely glazing of Items 7 is not required for the following installations: 1. A protective bar 1 1/2 inches ( 38 mm ) or more in height, capable of withstanding a horizontal load of 50 pif ( 730 N/m ) without contacting the glass, is installed on the accessible sides of the glazing 34 Inches ( 864 mm to 965 mm ) above the floor. 2. The outboard pane in insulating glass units or multiple glazing where the bottom exposed edge of the glass is 25 feet (1620 mm ) or more above any grade, roof, walking surface or other horizontal or sloped (within 45 degrees ( 0.78 red ) of horizontal ) surface adjacent to the glass exterior. 8. Glazing in guards and railings, Including structural baluster panels and nonstructural in -fill panels, regardless of area or height above a walking surface. 9. Glazing in walls and fences enclosing Indoor and outdoor swimming pools, hot tubs and spas where all of the following conditions are present: 9.1. The bottom edge of the glazing on the pool or spa side is less than 60 inches (1524 mm ) above the walking surface on the pool or spa side of the glazing; and 9.2. The glazing is within 60 Inches ( 1524 mm ) horizontally of the waters edge of a swimming pool or spa. 10. Glazing adjacent to stairways, landings and ramps within 36 Inches ( 914 mm ) horizontally of a walking surface; when the exposed surface of the glass Is less than 60 inches ( 1524 mm ) above the plane of the adjacent walking surface. 11. Glazing adjacent to stairways within b0 inches ( 1524 mm ) horizontally of the bottom tread of a stain,uay in any direction when the exposed surface of the glass Is less than 60 Inches ( 1524 mm ) above the nose of the tread. Exceptions: Safety glazing for Item 10 or 11 is not required for the following installations where: 1. The side of a stalmey, landing or ramp which has a guard or handrail, Including balusters or InAll panels, complying with the provisions of Section 1013 and 1607.7; and 2. The plane of the glass is greater than 18 inches ( 457 mm ) from railings. 2406.4.1 Exceptions. The following products, materials and uses shall not be considered specific hazardous locations: 1. Openings In doors through which a 3 inch ( 76 mm ) sphere is unable to pass. 2. Decorative glass in Section 2406.4. Item 1, 6 or T 3. Glazing materials used as curved glazed panels in revolving doors. 4. Commercial refrigerated cabinets glazed doors. 5. Glass block panels complying with Section 2101.2.5. 6. Louvered windows and jalousies complying with the requirements of Section 2403.5. 1. Mirrors and other glass panels mounted or hung on a surface that provides a continuous backing support. 2406.5 Fire department access panels. Fire department glass access panels shall be tempered glass. For insulating glass units, all panes shall be tempered glass. CONNECTION 50HEOULE Manufacturer Name Model No. FL Product Approval Location / Use SIMPSON "HETA-20" # 11473.3 AT ALL TRUSS / MASONTY YVAL-L CONNECTIONS SIMPSON "MT5-12" # 10456.8 AT ALL RAFTER / FRAMEWALL CONNECTIONS 51MP50N "L5TA-3b" # 10852.b EMBEDDED IN BLOCK CELL MORTA TO STRAP DOWN P.T. WOOD BEAMS ON TOP OF GONG. BLOCK COLUMNS 51MP50N "H10" # 10456.3 AT ALL WALL PLATEWRAFTER5 SIMPSON "EGGbb" # 10860.3 GAP LUMBER BEAM CORNERS ON P.T. POST 51MP50N "ECCLR" # 13904.3 GAP LUMBER BEAM CORNERS ON P.T. POST SIMP50N Wr Angle # 10446.1 ANCHOR P.T. WOOD POSTS ON TOP PLYWOOD FLOOR SIMPSON "5P2" # 10456.11 0 TOP PLATES SIMPSON 615101" # 10456.11 0 BOTTOM PLATE SIMPSON 11ABA66" # 10860.2 ANCHOR P.T. POSTS ON TOP OF NEW CONCRETE FOOTER SLAB. SIMPSON "HH4" # 10446.9 USE 16d Nails W/ "HH4" TO ATTACH FLOOR BEAM TO P.T. WOOD P05T 51MPSON "HGU548" # 10655.4 USE 16d Nails W/ "HGU548" TO ATTACH FLOOR BEAM TO FRAME WALL BASE BOARD SIMPSON "HU528" # 10655.24 HEAVY DUTY J015T HANGER -AT ALL PERPENDICULAR CONTACTS TO SECURE FLOOR JOISTS TO WALL. LEDGER BOARD 51MP50N "MBHA3.56/9.25" # 13904.5 AT BEAM/BLOCKWALL CONNECTION Note: 1. Any products that are substituted, must meet or exceed products specified. Contractor "must" provide data to building inspector at time of inspection. Residential Termite Protection R 318.1 Termite Protection. Termite protection shall be provided by registered termiticides, including soil applied pesticides, baiting systems and pesticides applied to wood, or other approved methods of termite protection labeled for use as a preventative treatment to new construction. See Section 202, Registered termiticide. Upon completion of the application of the termite protective treatment, a Certificate of Compliance shall be issued to the building department by the licensed pest control company that contains the following statement: "The building has received a complete treatment for the prevention of subterranean termites. Treatment is in accordance with rules and laws established by the Florida Department of Agriculture and Consumer Services." R 318.1.1 If soil treatment is used for subterranean termite prevention, the initial chemical soil treatment inside the foundation perimeter shall be done after all excavation, backfilling and compaction is complete. R 316.1.2 If soil treatment is used for subterranean termite prevention, soil area disturbed after initial chemical soil treatment shall be retreated with a chemical soil treatment, including spaces boxed or formed. R 515.1.3 If soil treatment is used for subterranean termite prevention, space in concrete floors boxed out or formed for the subsequent installation of plumbing traps, drains or any other purpose shall be created by using plastic or metal permanently placed forms of sufficient depth to eliminate any planned soil disturbance after initial chemical soil treatment. R 318.1.4 If soil treatment is used for subterranean termite prevention, chemically treated soil shall be protected with a minimum b mil vapor retarder to protect against rainfall dilution. If rainfall occurs before vapor retarder placement, retreatment is required. Any work, including placement of reinforcing steel, done after chemical treatment until the concrete floor is poured, shall be done in such manner as to avoid penetrating or disturbing treated soil. R 318.1.5 If soil treatment is used for subterranean termite prevention, concrete overpour or mortar accumulated along the exterior foundation perimeter shall be removed prior to exterior chemical soil treatment, to enhance vertical penetration of the chemicals. R 318.1.6 If soil treatment is used for subterranean termite prevention, chemical soil treatments shall also be applied under all exterior concrete or grade within 1 foot (305 mm) of the primary structure sidewalls. Also, a vertical chemical barrier shall be applied promptly after construction is completed, Including initial landscaping and Irrigation/sprinkler installation. Any soil disturbed after the chemical vertical barrier is applied shall be promptly retreated. R 318.1.1 If a registered termiticide formulated and registered as a bait system is used for subterranean termite prevention, Sections 1816.1.1through 1816.1.6 do not apply; however, a signed contract assuring the installation, maintenance and monitoring of the baiting system for a minimum of 5 years from the Issue of the Certificate of Occupancy shall be provided to the building official prior to the pouring of the slab, and the system must be installed prior to final building approval. If the baiting system directions for use require a monitoring phase prior to installation of the pesticide active ingredient, the installation of the monitoring phase components shall be deemed to constitute installation of the system. R 318.1.8 If a registered termiticide formulated and registered as a wood treatment is used for subterranean termite prevention, Sections 1816.1.1 through 1816.1.6 do not apply. Application of the wood treatment termiticide shall be as required by label directions for use, and must be completed prior to final building approval. Changes in framing or additions to framing in areas of the structure requiring treatment that occur after the initial wood treatment must be treated prior to final building approval. R 316.2 Pentration. Protective sleeves around piping penetrating concrete slab on grade floors shall not be of cellulose containg materials. If soil treatment is used for subterranean termite protection, the sleeve shall have a maximum wall thickness of 0.010 inch (0.254 mm), and be sealed within the slab using a noncorrosive clamping device to eliminate the annular space between the pipe and the sleeve. No termiticides shall be applied inside the sleeve. SOIL 15 TO BE COMPACTED TO 95% MODIFIED PROCTOR AS DEFINED BY ASTM D 1551- 91. STRUCTURAL NOTES: 1. CODES: 1.1 Current edition of The Florida Building Code Residential 20201th Edition. 1.2 Building code requirements for reinforced concrete (AGI 318.06). 1.3 American Society of Civil Engineers minimum design loads for buildings and other structures (A5CE 1.10). 2. SOILS: 2.1 Assumed allowable soil pressure 1,500 PSI. 3. CONCRETE: 3.1 Concrete compressive strength at 28 days: 3,000 PSI (Normal weight). 3.2 Reinforcing bars: A5TM A615 (Grade 60). 3.3 Welded wire fabric (WWF): A5TM A185. 3.4 Detail reinforcement in accordance with AGI 315. 3.5 Concrete coverage of reinforcement: Footings 3; bottom and sides. 3.6 Earth supported slabs: (Including exterior walk and driveway slabs) 3 W thick, reinforced with 6 x 6 -10 x 10 WWF at mid depth of slab. Fiber -mesh may be used in lieu of WWF at contractor's option. 3.1 Concrete operators shall comply with AGI standards. 3.8 Lap splice shall be as follows: #5 bar 25"; #4 bar 20" and #3 bar 15". 4. MASONRY: 4.1 Design and construction shall conform to the specification of the National Concrete Masonry Association and AGI 530. 4.2 Minimum masonry unit strength: fm 1,900 PSI. 4.3 Mortar shall be type "S" or "M'. 4.4 All block cells and cavities below grade shall be filled with concrete when stem wail is greater than 24" tall above grade. 5. WOOD: 5.1 Wood structural framing members: #2 Southern Yellow Pine (unless noted otherwise) with an allowable bending stress (fb) per ND5-91 = 1,250 P51 and a modulus of elasticity = 1,600,000 1*51. 5.2 All exposed wood or wood in contact with earth or concrete to be pressure treated. 5.3 Roof sheathing: 1 /2" G-D grade plywood (or 15/32" 055) under 30# felt under 240# fiberglass shingles. 5.4 Untreated wood shall not be in direct contract with concrete. Seat plates shall be provided at bearing locations without wooden top plates. WIND PRESSURES AS PER FBC 2020 FOR EXPOSURE B AT 140 MPH WINDS(LRFD) Zone 10 + - 20 + - + 50 - 100 + - 1 19.52 -30.4 17.76 -28.8 16 -28.8 16 -27.2 2 19.52 -52.8 17.76 -49.6 16 -43.2 16 -38.4 3 19.52 -78.4 17.76 -73.6 16 -67.2 16 -62.4 4 29.5 -31.9 28.2 -30.6 26.5 -28.9 25.1 -27.6 5 1 29.5 -39.3 28.2 -36.7 26.5 -33.2 25.1 -30.6 ZONE 1 = ROOF INTERIOR ZONE 2 = ROOF EDGE STRIP ZONE 3 = ROOF CORNER ROOF SHEATHING FASTENING SCHEDULE 6'-0" STRIP 8d RING -SHANK NAILS AT 6" O.G. AROUND AT EDGES AND PERIMETER INTERMEDIATE SUPPORTS. 8d NAILS AT 6" O.G. AT EDGES AND INTERIOR INTERMEDIATE SUPPORTS. GABLE ROOFS 10"<0s45'* ZONE 4 = WALL INTERIOR ZONE 5 = WALL CORNER BUILDING DIMENSIONS DIM a 6 feet b 21 feet, 9 Inches c 4 slope d 4 feet e 4 feet h 20 feet, 0 Inches s 12:4 slope �% � A 1 On -i; 0 :s 450 HIP ROOFS 104,c 8 & 300 DE516N WIND CRITERIA (FBC 2020 7th E0.) BASK WIND SPEED M: 140 MPH BUILDING CLASSIFICATION 11 WIND IMPORTANCE 1.0 FACTOR (1): WIND EXPOSURE: B INTERNAL PRESSURE COEFFICIENT (GGpl) +/_ 0.18 DESIGN WIND PRESSURE FOR EXTERIOR COMPONENT 8 CLADDING MATERIALS: TAB.6 - 35 ASCE 1-10 DOORS 41.15 PSF WINDOWS 49.25 PSF NOTE: THIS BUILDING HAS BEEN DESIGNED TO RESIST WIND INDUCED SHEAR AND UPLIFT FORGES, AS SPECIFIED TO COMPLY WITH THE FLORIDA BUILDING CODE, 2020 RESIDENTIAL 7th EDITION, SECTION R 301.2.(1) WITH A 3 SECOND WIND GUST 100 0!5 30° For S1:1 foot = 304.8 mmd 1 degree = 0.017.5 rad_ Note: a = 4 feel[ in all cases. FIGURE R301r2M COMPONENT AND CLADDING PRESSURE ZONES i A. LICENSE No 4743 ,. .ow -�- �i STATE OF e' �i FLORIDA This Item has been electronically signed and sealed by Ram Goei using a Digital Signature and date. Printed copies of this document are not considered signed and sealed and signature must be verified on any electronic copies Dig" sows by Ram Goel DN: E-Soneyhmllceyahoo. com, Ram GoelONmEam�, OUmENGINEERING, 0--Sony FM LLC, L=Tampa, S-FWWa, C-US Date: 2022.0e.11 Ia12:21-" y I HEREBY CERTIFY THAT I HAVE REVIEWED AND SUPERVISED THE ATTACHED DESIGN AND FOUND IT TO BE IN COMPLIANCE WITH THE 2020 F.B.G. RESIDENTIAL TTH EDITION DR. RAM A. GOEL, P.E.(#41431) 50NEY FM LLC, GA # 9146 GORY LAKE PROFESSIONAL CENTER 10529 CROSS CREEK BLVD., SUITE P TAMPA, FL 35641 Ph: 813-293-1868 m W Q IL W IL N Z IL " r v S6z9P��,�a �i �1