HomeMy WebLinkAbout5953 Gall BlvdI--- -ILL--- - I _ i 4 I`I I f rlf l' P lt''II 'I III I'll I I' II+-_ f I B a DRAWING ABBREVIATIONS _ DIMENSIONING GENERAL NOTES LISTED HERE AND USED THROUGHOUT THE DRAWINGS ARE COLLMAN AND KARSKY THE FOLLOWING GENERAL NOTES SHALL PERTAIN TO THE ENTIRE SET OF OCCUPIED AREAS OF THE BUILDING THROUGHOUT ALL PHASES OF ARCHITECTS OFFICE STANDARDS FOR CONSTRUCTION TERMINOLOGY. OTHER ACCEPTED I. IN MANY OF THE INTERIOR SPACES THE ACTUAL 5. PARTITION WITH A FINISHED FACE FLUSH WITH FINISH 8. DOOR LOCATIONS ARE TO BE LOCATED BY ONE OF PRODUCED CONTRACT DOCUMENTS. CONSTRUCTION. N LISH E GT ABBREVIATIONS 0 H HAN H 0 FOLLOWING ER T THE MAY BE USED: G Y DIMENSIONS MAY BE LESS IMPORTANT THAN IF AT TWO FACE OF COLUMN WILL NOT BE DIMENSIONED ON SMALL "ELEMENTS FOLLOWIN G A. ALL CONSTRUCTION WORK SHALL BE DONE IN ACCORDANCE WITH THE Y. THE EXTENT OF WORK SHALL BE LIMITED TO THAT INDICATED IN THE IN THE BUILDING WERE TO BE EQUAL. IN SCALE PLANS BUT WILL BE DRAWN ACCORDINGLY. n „ THESE CASES THE EQUAL OR EQ IS USED IN A. ONE JAMB FACE LOCATED BY A PARTITION AT REQUIREMENTS OF THE BUILDING CODE AND AMENDMENTS AND ALL OTHER CONTRACT DOCUMENTS. NO ADDITIONAL WORK SHALL BE DONE WITHOUT A.F.F.ABOVE F F A.F. A.C.T. FINISH 00 B F FLOOR ACCESS FLOOR.. ACOUSTICAL CEILING TILE MAIN T MN .MANHOLE MANUF` MAINTENANCE T E MANUFACTURER � .WORD LIEU OF THE ACTUAL DIMENSIONS. COLUMN f CENTERLINE.. RIGHT ANGLE. TYPICAL UNLESS INDICATED ON G G TYP A PLAN. B. APPLICABLE LAWS.. S GENERAL CONTRACTOR SUBCONTRACTORS ARE TO ABIDE WITH THE ,WRITTEN APPROVAL OF TENANT. ANY ADDITIONAL .WORK PERFORMED WITHOUT F O WRITTEN A PRIOR R TTEN APPROVAL BY OWNER SHALL BE AT THE CONTRACTOR'S AHU AIR HANDLER UNIT NB MARKER BOARD 2. WHEN A ROOM CENTERLINE IS INDICATED ONLY ONE _ __ PARTITION AS PARTITION AS SCHEDULED. APPLICABLE BUILDING RULES AND REGULATIONS. GENERAL CONTRACTOR AND EXPENSE. ALUM ALUMINUM MAS N.O.MASONRY MASONRY OPENING 0 RY PE G SI 0 H ROOMS MAY DE F THE R ELEMENTS Y BE DIMENSIONED. 3 SCHEDULED. ED LED. SUBCONTRACTORS ARE RESPONSIBLE IN OBTAINING COPIES OF THE SAID Z. NO MO I ICA IONS/ ISIONS/GRAN D F T REV GES SHALL BE UNDERTAKEN UNLESS A.B. ASB ANCHOR BOLT ASBESTOS. MAT L MATERIAL COLUMN IDENTIFICATION DETAILS WILL GOVERN ALL - - . BUILDING RULES AND REGULATIONS...: - G SPECIFICALLY SO INS U _ TR CTED AND APPROVED BY TENANT. -ASPH ASPHALT MAX MAXIMUM IMUM DIMENSIONSNSIONS ANDNODIDIMENSIONS WILL BE SHOWN ON 6. PARTITION FINISH FACE ON COLUMN ORGRIDLILINE WILL C. THE CONTRACTOR SHALL EXAMINE THE PREMISES CAREFULLY VERIFY AND BE AA: WHERE PRODUCTS ARE SPECIFIED BY REFERENCE STANDARD OR IN � ,q T MSL MECH MEAN SEA LEVEL MECHANICAL SMALL SCALE PLANS. NOT BE DIMENSIONED ON SMALL SCALE PLANS BUT I �M RESPONSIBLE' FOR ALL FIELD. DIMENSIONS ,AND CONDITIONS .AND NOTIFY THEDESCRIPTIVEMANN WI HOU MA , ER WITHOUT NUFACTURER S NAME, MODEL NUMBER OR B M BE AM MEMB MEMBRANE WILL BE DRAWN ACCORDINGLY: COLUMN „ 4 TYP DOOR AS SCHEDULED. ARCHITECT OF ANY DISCREPANCIES BEFORE PROCEEDING THE WORK: G TRADE NAME CONTRACTOR. SHALL SELECT MATERIALS MEETING SPECIFIED , BRG BITUM BEARING BITUMINOUSR M TL. MEZZ METAL ET L MEZZANINE CENTERLINE: 0 AS DIMENSIONED B. R D EN ZONED. ON PLAN. D. CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS AN U R L R,D EQUIPMENT AS WHICH 0 NO C REQUIREMENTSD T ONTAIN KNOWN HAZARDOUS SUBSTANCES IN BLK (G) BLOCK IN ( G) MIN MINIMUM :.REQUIRED TO COMPLETE WORK. ANY FORM AND SUBMIT TO ARCHITECT FOR APPROVAL. BD BOARD -------.-;—PARTITION A S - BTM. BOTTOM N/A NOT APPLICABLE SCHEDULED. q. PARTITIONS ARE DIMENSIONED TO FACE OF CMU OR E. IF UNANTICIPATED MECHANICAL, ELECTRICAL OR STRUCTURAL ELEMENTSAB. INSTALL ALL MANUFACTURED URED ITEMS, MATERIALS AND EQUIPMENT INSTRICT BLDG. BUILDINGTER. NC NON-COMBUSTIBLE FACE OF STUD UNLESS 0 N WIS NO E TED. THAT CONFLICT WITH THE INTENDED FUNCTION OR DESIGN ARE ENCOUNTERED, ACCO ANC W HMANUFACTURER'S RD E IT TH ERECOMMENDED SPECIFICATIONS B.U.R.BUILT-UP R 00 F N.I.C. N S T NO IN CON ACT T CONTR NO 0 SCALE NOT L A I ION CENTERED ON COLUMN 4. P RT T E TEEED L OR GRID. LINES WILL 7. OPENINGS. OCCURRING IN PARTITIONS OR WALLS: INVESTIGATE I A AN MEASURE BOTH H NATURE ANL VE T G TE D E RE B T THE T RE D EXTENT OF CONFLICT C' A N SPECIFICATIONS E H CI IC ONS HEREIN W EXCEPT THAT THE PE F TI ERE HERE MORE STRINGENT,5NAL , CAB CABINET # N0. NUMBER. NOT BE DIMENSIONED ON SMALL SCALE PLANS BUT p L . DIMENSIONS_ ARE INDICATED IN THE DOCUMENTS. THE AND SUBMIT CONFLICT TO ARCHITECT TO PREVENT UNDUE DELAY:WITH. BE COMPLIED` CPT C:B. CARPET. CATCH BASIN O.C. ON CENTER WI A A WILL BE DRAWN ACCORDINGLY. A. WHEN ONE JAMB OCCURS AT A COLUMN OR RID LINE G DRAWINGS SHALL NOT BE SCALED FOR DIMENSIONS. F. IF HAZARDOUS MATERIALS- ARE ENCOUNTERED. DURING CONSTRUCTION AC. IN MAKING O SUBSTITUTION, CON C K G F R CONTRACTOR SHALL BE C I C.I.P. CAS IN C T PLACE OCC OCCUPANCY Y COLUMN CENTERLINE. R �' NO DIMENSIONS WILL SHOW ON D E LL BE N THE SMALL SCALE PLANS. N OPENING WIDTH WILL GOVERNED L THE PE DT LL BE VER ED B G G Y OPERATIONS, 10 S COMPLY WITH. APPLICABLE REGULATIONS, 10 S P _RAT _N , PL .BLE REG L T N ,LAWS AND RESPONSIBLE RE PO SIBLE FOR DETERMININGTHAT MATERIALS T T M TERI LS REQUESTED FOR CL G CEILING LRE GFREE OPN G OPENING G CRITERIA OR SCHEDULES. _ ORDINANCES S CONCERNING REMOVAL, HANDLING A RD E ER G REM V L H NDL NG AND PROTECTION AGAINST SUBSTITUTION A 0 NOW A EE N HAZARDOUS SUBSTANCESN A F K AZ RD I ANY FORM. CID CENTER LINE CEMENT A PLASTER OPP 0. TO 0. OPPOSITE OUT TO OUT - - : E 05URE OR ENVIRONMENTAL POLLUTION. XP T A D. WARRANTY SHALL RR TY ALL BE EXTENDED FOR ALL CONSTRUCTION COMPONENTS , C.T. AMC CERAMIC TILE O.D.OUTSIDE .D. IM NSION T DE D E PARTITION AS H B. W EN NEITHER JAMB OCCURS A A CO UMN 0 T L R GR D G. CONTRACTOR PROVIDE PROPER. AND ADEQUATE MEANS OF PROTECTION. FOR EQUIPMENT AND. INSTALLATIONS 1NC U 1N HIS CON T T INCLUDED T TRACT FOR A MINIMUM. C KT _ CI CUI CIRCUIT O.A. OVERALL ER LL SCHEDULED. ED LED.-G LINE ONE _JAMB WILL DIMENSIONED. BE EXISTING WORK AND FINISHES TO REMAIN AND NEW WO OS WORK EXPOSED TO -0F I YEAR FROM THE DATE OF SUBSTANTIAL COMPLETION. T PLET CLR CLEAR COLUMN PTD. PR. PAINTED P TED PAIR , LIKELY SOUC S 0F DAMAGE DURING THE CONSTRUCTION PERIOD INCLUDING AE. ` ALL REQUESTS FOR SUBSTITUTIONS TIONS SHALL BE SUBMITTED IN WRITING TO THECOL CONC CONCRETE P.T.D. PAPER TOWEL DISPENSER DRAWING SYMBOLS TORS BREAKAGE.TENANT GLASSCONSIDERATION, AND ARCHITECTFOR CMU CONCRETE MASONRY UNIT CONCRETE MONUMENT P.T.W. PAPER TOWEL WASTE H. THE CONSTRUCTION OPERATION SHALL NOT DISRUPT BUILDIN SERVICES I E. AF. FINAL CLEANING A COMPLETION SHALL FINISHE LL INCLUDE DUSTING ING 0F ALL D CONN CONNECT(ION) PT BD: PARTICLE BOARD PART,N PARTITION FIRE PROTECTION, ION, FIRE ALARM, HVAC, AND POWER) TO THE OTHER TENANTS SURFACES, VACUUMING, REMOVAL OF SPOTS, STAINS, LABELS, FINGERPRINTS, CONT CONTINUOUS PL PLASTIC DRAWING IDENTIFICATION:I ICA IN 6. ELEVATION LEVELS 10. PARTITION/WALLKEYS SEE SHEET AI01 FOR OF THE BUILDING, DISRUPTION SHALL BE COORDINATED WITH THE LANDLORD SPILLS AND CLEANING OF ALL INTERIOR GLASS,JOB SITE CLEAN-UP SHALL C.J. CONTROL JOINT T PLMB PLUMBING PARTITION .TYPES AND NOTES. PRIOR T0 PROCEEDING WITH WORK. - CONTINUE BEYOND DATE' OF SUBSTANTIAL COMPLETION TO MOVE IN DAY AND CSK CU COUNTERSUNK COPPER PPG YWOOD LYWOOD PL POLISHED PLATE GLASS TRUE DIRECTION IDENTIFICATION- DRAWING SECTION/ELEVATION REFERENCE: I. PATCHING MATERIAL SHALL MATCH EXISTIN ADJACENT MAT RIA S AS G , E L SHALL INCLUDE REMOVAL 0 ACCUMULATED LL L DE RE V L F L TED DEBRIS RESULTING .FROM WORK CORR CORRIDOR LBS POUNDS SC I ION E R PT "RI ,_ ,I � ELEVATION HEIGHT ELEVATION. 0 0 � PARTITION CLOSELY AS POSSIBLE IN COLOR PATTERNS AND/OR TEXTURES:D , , BY TELECOMMUNICATIONS CONTRACTORS AN 0 HVENDORS, TER. UNDER' DP DAMP PROOFING PRFB PREFABRICATED • PLAN DEST ION ,l ELEVATION TARGET DESCRIPTION o CONTRACT TO THEOWNER. DEMO DEMOLITION P.T. S PRESSURE TREATED � �� ELEVATION LOCATION o 3 PARTITION TYPE J. SEALANTS SHALL BE COMPATIBLE WHERE IN CONTACT WITH ONE ANOTHER, D ET DETAIL D L PROJ. PROJECTION PERPENDICULAR PROPERTY LINE _ SCALE: 0 = 0 -0 NOTEI • • • • _ K. AG. ,CAULK JOINTS OF DISSIMILAR MATERIAL EXPOSED TO VIEW... AS REQUIRED BY FIRE RATED PARTITIONS SHALL BE NOTED IN STENCIL ABOVE FINISHED CEILING PER APPLICABLE CODE:' DIAG DIAGONAL H' ADDITIONAL NOTES � ` SITE PLAN REFERENCE: THE ARCHITECT, DIA DIAMETER Q .T. QUARRY I Q RRY TILETHE DRAWING SCALE ELEVATION HEIGHT " n W INDICATES N CONSTRUCTION OF THE AH. VERIFYSPECIFIC SECURITY QUI M F REQUIREMENTS ENTS WITH TENANT. DIM DIMENSION RAID RADIUS PLAN NORTH INDICATOR I ELEVATION: 0'-0" ELEVATION TARGET WALL AS LOAD -BEARING: L. GENERAL CONTRACTOR TO HAVE PORTABLE FIRE EXTINGUISHERS PLACED ON DIST'N DR DISTRIBUTION DOOR R.W.L. RAIN WATER LEADER DESCRIPTION ELEVATION LOCATION: , FLOOR DURING CONSTRUCTION. DN DOWN RECMD. RECOMMENDED ' P" INDICATES THAT THE CONSTRUCTION OF N. DO NOT SCALE DRAWINGS. IF DIMENSIONS ARE IN QUESTION, THE IDS DOWNSPOUT REF. REFERENCE - THE PARTITION EQUAL A NON BEARING WALL. CONTRACTOR SHALL BE RESPONSIBLE FOR. OBTAINING CLARIFICATION FROM. DVTL W DWG DOVETAIL DRAWINGS DR G REINF RCP REINFORCED REINFORCED CONCRETE PIPE 2. DETAIL IDENTIFICATION: 7. SECTION KEY MARKS: THE ARCHITECT BEFORE CONTINUING WITH CONSTRUCTION. D.F. DRINKING FOUNTAIN R.P. RENO REFERENCE POINT RENOVATION DETAIL IDENTIFICATION p SECTION NUMBER N. !!WARNING!! SCHEDULE AND PERFORM ALL CONSTRUCTION WORK SUCH THAT DIP DW DUCTILE IRON PIPE -- --. -__: -- GYPSUM DRYWALL , ,.:_ � REQ D REQUIRED DETAIL DESCRIPTION SECTION DIRECTION 0.0 SHEET LOCATION SECURITY IS MAIN MAINTAINED 100� 0 H TIME T ED F THE T E THROUGHOUT THE CONSTRUCTION RESIL RESILIENT i II. SYMBOL LEGEND: , PERIOD. COORDINATE WITH AND FOLLOW `TENANTS AND LANDLORDS EA ELEC EACH ELECTRIC(AL) RE V. R.O.W. RE VISION RIGHT OF WAY OO DETAIL— DESCRIPTION - i - 00 TOILET ACCESSORY DIRECTIONS. E.W,C ELECTRIC WATER COOLER R RISER ( SCALE: 0 = 0'-011 NOTES 0. SEAL ALL PENETRATIONS IN WALLS, FLOORS, AND CEILINGS. ELEV EL ELEVATION ELEVATOR R.D. ROOF DRAIN 8. EXTERIOR/INTERIOR ELEVATION REFERENCE MARKS: 000 WINDOW P. CONTRACTOR SHALL HAVE ACCESS ON THE PROJECT SITE LIMITED TO THE ERCP ELLIPTICAL REINFORCED RI. RN RIDGE ROOM NUMBER AREA WITHIN THE SCOPE OF WORK. ENT CONCRETE PIPER.O.ROUGH ENTRANCE R OPENING R G PE G ADDITIONAL NOTES -� ELEVATION DIRECTION 00/A000 00 KEYNOTE NUMBER - Q. PRIOR TO COMMENCING WORK THE CONTRACTOR SHALL SUBMIT 2 COPIES ( ) EQ EQUAL SND SANITARY NAPKIN DISPOSAL DETAIL SCALE NEW/RENOVATION OF MATERIAL SAFETY DATA SHEETS (MSDS) FOR ALL PRODUCTS USED TO EXIST EXPN EXISTING EXPANSION SEAL SECT SEALANT SECTION SHEET NUMBER 00 00 00.XX KEYNOTE NUMBER -NEW PERFORM THE WORK. E.J. EXPANSION. JOINT S.M. SHEET METAL 3. ROOM/SPACE IDENTIFICATION NOTATION: ELEVATION NUMBER C.S.I. DIVISION/KEY R. ALL SUBCONTRACTORS ARE REQUIRED TO COORDINATE THEIR WORK WITH EXP EXPOSED SHWR S/W SHOWER ROOMNAME- ROOM DESCRIPTION R D P q. DETAIL- REFERENCE MARKS: OTHER TRADES. LACK OF THIS' COORDINATION RESULTING I T RE LT G N ADDED COST E.C. OS 0 EXPOSED CONSTRUCTION SIM .SIDEWALK SIMILAR 0000 ROOM NUMBER 00 KEYNOTE NUMBER - A BORNE TO THE CONTRACT WILL BE B R E BY THE CONSTRAGOTR OR EXT EIFS EXTERIOR , EXTERIOR INSULATION FINISHING SC SCW SOLID CORE SOLID CORE WOOD 00,00,0 WALL FINISH - _ DEMOLITION SUBCONTRACTOR. SYSTEM SCFW SOLID CORE FLUSH WOOD BASE FINISH ' ` 000 00 � DOOR NUMBER S. TEMPORARY BARRICADES AND :OTHER SAFETY MEASURES SHALL BE ERECTED F.O.B. FACE OF BLOCK SIP SPACE FLOOR FINISH ' AROUND HAZARDOUS AREAS IN ACCORDANCE. WITH ALL APPLICABLE CODES. FIN F.V. FINISH ED ( ) V FIELD VERIFY SPEC SPECIFICATION LIMITS L__J-�o0FRCP 00 GLAZING TYPE TAG AND ORDINANCES. : SQ SQUARE RE COLUMN AND/OR GRID LINES.NUMBER FIRE ALARM CONTROL PANELA. SF SQUARE FOOT 0.0 SHEET LOCATION T. CUTTING OF. EXISTING CONSTRUCTION FOR THE INSTALLATION OF ALL NEW FATP FIRE ALARM TRANSCEIVER PANEL S.S. STAINLESS STEEL 00-DO INTERIOR FINISH TA 0 G WO A TRADES, AN HE SUBSEQUENTA C RK BY ALL TR DE , D T.PATCHING RING THEREOF,- SHALL F.E. F.E.C. FIRE EXTINGUISHER FIRE EXTINGUISHER CABINET STL STRUCT. STEEL STRUCTURAL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR, WHETHER THE F. H C I HOSE CABINET FIRE E B ET SUSP SUSPENDED A � 00 REVISION NUMBER WORK IS' DONE BY HIS OWN FORCES OR NOT. GRINDING OF MATERIALS FOR FPFG FIREPROOFING REMOVAL SHALL NOT BE PERMITTED. CUTTING SHALL BE TO STRAIGHT IN G LINE. FLR FLOOR TB TE. TACK BOARD TELEPHONE - UNWORKMANLIKE CUTTING, DAMAGE RESULTING THEREFROM AND F.D. FOOT FLOOR DRAIN FLORIDA DEPARTMENT OF TBM TEMPORARY BENCH MARK 1 12. DOOR IDENTIFICATION NOTATION: UNACCEPTABLE PATCHING SHALL BE REPAIRED AND/OR REPLACED TO AN TRANSPORTATION T.G. TEMPERED GLASS . ACCEPTABLE CONDITION APPROVED BY THE ARCHITECT. !!NOTIFICATION!! AN FT. FOOT TEXT TEXTURED T - MORE THAN ONE DOOR OWNER PROJECT REPRESENTATIVE .SHALL. BE NOTIFIED .PRIOR TO CUTTING OF FTG FOOTING THRESH TPH THRESHOLD TOILET PAPER HOLDER 5. FLOOR PLANLINES: THIS AREA.:. ANY STRUCTURAL ITEM (I.E. CONCRETE FLOOR, MASONRY, WALL,- ETC.) FR F.L.M FRAME FULL LENGTH MIRROR � VG TONGUE � GROOVE T G G _MATCH 8' o ROOM NUMBER WITHIN THE EXISTING BUILDING. METHOD OF CUTTING SHALL BE APPROVED FURN FURNISH TtB TOP It BOTTOM I BY THE OWNER PROJECT REPRESENTATIVE. F.O.S FACE OF SLAB T.O.C. T.O.F. TOP OF CONCRETE TOP OF FOOTING U. ALL SALVAGE MATERIALS REMOVED SHALL REMAIN THE PROPERTY OF THE G ALV. GALVANIZED G T.O.G. TOP OF GRADE , TENANT 0 LANDLORD. A NON -SALVAGE TE T R L DL RD. ALL LV GE CONSTRUCTION MATERIALS AND G.I.GALVANIZED IRON G R T.O.P. TOP OF PAVING — - - - DEBRIS FROM: DEMOLITION- WORK SHALL BE REMOVED FROM E H SITE AS T GA GAUGE T.O.S. TOP OF STEEL � WORK PROGRESSES. G G.C. GENERAL CONTRACTOR T TREAD - GL. GLASS TYP TYPICAL V. ISOLATE ALL DISSIMILAR METALS. GB G.E. GRAB BAR GRATE ELEVATION U G UNDERGROUND W. N CONTRACTORSNA :MAIN MAINTAIN A CLEAN A THE SHALL T LE AND ORGANIZED .JOB. SITE G.S.GRAVEL STOP U.L. UNDERWRITERS LAB _ ACCEPTABLE TO THE LANDLORD AND TENANT. G ND GROUND U.N.O. UNLESS NOTED OTHERWISE G.F.I.GROUND ROUND FAULT INTERRUPT UIR URINAL X. THE CONTRACTOR WILL VERIFY THAT EXIT EGRESS IS MAINTAINED FOR ALL GYP GYPSUM V. VALLEY AC HP HAN ICA D HANDICAPPED V.P. VENEER PLASTER MATERIALS PATTERN N TER LS P TTER LEGEND HDW HARDWARE v.I.F. VERIFY IN FIELD _ H T G HEIGHT G VERT VERTICAL I: EXISTING REINFORCED CONCRETE SLAB TO REMAIN. HID HIGH INTENSITY DISCHARGE VEST VESTIBULE THE GRAPHIC INDICATIONS OF MATERIALS SHOWN HERE AND USED THROUGHOUT THE DRAWINGS 2. NEW 411- 611( MATCH EXIST. ) 3,000 PSI CONCRETE SLAB ( AT 2B DAYS H.P. HIGH POINT V.B. VINYL BASE C ARE COLLMAN AND KARSKY ARCHITECTS OFFIE STANDARDS. THEY ARE NORMALLY USED IN LIEU 3. MINIMUM 6 MIL POLYETHYLENE VAPOR BARRIER OVER WELL COMPACTED, 'TERMITE TREATED FILL. H.M. HOLLOW METAL V.C.T. V.W.C. VINYL COMPOSITION -TILE VINYL WALL COVERING (NOTED) OF WRITTEN NOTED IDENTIFICATION: WRITTEN IDENTIFICATION TAKES PRECEDENCE OVER GRAPHIC 4: NEW SLAB TO BE PINNED WITH #4 REBAR AT 24" O.C., STAGGERED TO PREVENT VERTICAL MOVEMENT. DRILL AND EPDXY 6" MIN. INTO HC CONCRETE HARDENED It SEALED INDICATED. EXISTING SLAB. NORIZ HORIZONTAL WC WATER CLOSET H.C. H.R. HOSE CONNECTION HANDRAIL N.H. HP(G) WATER HEATER WATERPROOFING ACOUSTICAL CEILING TILE ENLARGED CONCRETE GRASS - ELEVATION PARTICLE BOARD ENLARGED IAW IN ACCORDANCE WITH N.W.F. WELDED WIRE FABRIC ALUMINUM L WOO (ENLARGED) � PLYWOOD (E L RGED) IN. INCH W.D. WINDOW DIMENSION CONCRETE MASONRY UNIT w w GRASS -PLAN W EXST. CONCRETE SLAB NEW PINNED CONCRETE SLAB EXST. CONCRETE SLAB ID INSIDE DIAMETER WDW WINDOW A ASPHALT CONTINUOUS WOOD (ENLARGED) RIGID INSULATION I.D. INSIDE •DIMENSION W/ WITH Q o.,D 0 0 GRAVEL INSUL INV INSULATION INVERT WD W.P. WOOD WORKING POINT BATT INSULATION FACE BRICK STEEL 4 3 2 4 I I.E. INVERT ELEVATION T IN A UCCO SUM UCCO JAN JANITOR T R III I I I I I TN BELOW GRADE EARTH / ST FINISHED W00 D T �s , v... ,.. ,... ,. ..: . _ .......: j ........a, r. .., _. _. .. ...gym ,,..,.. .. JT.JOIN _ II nl III -III INSULATION _ KV AMPERES KILOVOLT PER INTERMITTENT WOOD BLOCKING (ENLARGED) ..,._ v M €ate..._ ..... ,. a Q �._ .�• -.,..... ' ,... a , , LAM LAMINATED a . ,. cf �J LG LENGTH „d L .WT T LIGHT HEIGHT G -------------- ----------------------- - . . . . . / LR LIMEROCK :. L F LINEAR FEET . L.L.V. LONG LEG VERTICAL L.P. LOW POINT N A I(AT- PINNED CONCRETE SLAB DETAIL TRENCH IN FILL SCALE: 3" = I1-0" ' g C&I< ARCHITECTS INTERIORS architecture •interior design -client services AAC00162.9' 4221 WEST BOY SCOUT BLVD., SUITE 150 TAMPA, FL 33607-5743 813.884.2000 280 WEST CENTRAL AVE. WINTER HAVEN, FL 33880-2957 863.577.2054 o< u- w z 01 0 QL eS. RAG tQ z 0 !2 W meWilli W O z J ui m _ a 5 W N Cn Cn 0 0 Z Q w m W I— a 0 _ Za W IV 0 C/ Z Q 0 m loo H Q m W m MCle W MM W ,,Jnn V Q M L0 01 v7 ISSUED FOR: PERMIT PROJECT NUMBER 21020 DATE 5.5.21 DRAWING NUMBER Al 01 1 i. : 1. 11 M I IK I I I I II II I Il._1I_. _1_ 1 J_ I III I I I I 1d 1` 11 11II'!III 111 l 1i 91� I 11 Iil l r n I 11N1` r r t � � t 1Y C&K ARCHITECTS INTERIORS architecture -Interior design -client services AAC001629 4221 WEST BOY SCOUT BLVD., SUITE150 TAMPA, FL 33607-5743 813.884.2000 280 WEST CENTRAL AVE. WINTER HAVEN, FL 33880-2957 863.577.2054 q I aP. I1L7 �� . � �Q • �Fiy �4 Z o,, Cl m ( LU Q, Q m RE z O N W K m W - rQ G O z N J J_ _ a w N 0 noo ii W CL C/� v0' 5- O W IV ^ v/ w LL. J k1 m 0 J CD J J ,Qn V M u7 U Lo ISSUED FOR: PERMIT PROJECT NUMBER 21020 DATE 5.5.21 DRAWING NUMBER - N n f\ W 9 � O k Q C&K ARCHITECTS INTERIORS Q architecture •Interior design -client services U AAC001629 m. 4221 WEST BOY SCOUT BLVD., SUITE 150 TAMPA, FL 33607-5743 U Q 813.884.2000 w 280 WEST CENTRAL AVE. Q WINTER HAVEN, FL 33880-2957 w 863.577.2054 a } LL Z Qccc G O W Z >Z_ Q ° N w W K lL � 0�0 5 Y \ • ;1�y0 ,'j : I a N ;o m Z fA Z Q w w K Z m N ° Z a U ui O ° z Q Q Z u Q w z O w N w W z � w K W F O m Q p 0 Z Z O x z O J C� W z K J- - 7 Qi K } w _ w CL W N z Z Z 0 0 O a Q LLJ— I Z a O z J m w w a C CX o } z 2 0 w w 0 V "� z w Q m m LL z V _ Q Z w CID ° z aC w H Z J Co V M Z u7 Q 01 L0 p N 2 ISSUED FOR: Z PERMIT z z PROJECT NUMBER O 0 21020 z O a DATE 5.5.21 z DRAWING NUMBER u z a A200 >' z z W W Z 0 � C C&K ARCHITECTS I INTERIORS architecture -interior design • client services AAC001629 4221 WEST BOY SCOUT BLVD., SUITE 150 TAMPA, FL 33607-5743 813.884.2000 280 WEST CENTRAL AVE. WINTER HAVEN, FL 33880-2957 863.577.2054 i , c L i L O U. L C i C C C 7 u C u O H > W o f 0 a0 W 0 u 0 C `u F u O z LL Q � u J J u S C - od a d u LU N a Z a L a LL CL 0 I� C Z I� Ck 0 LL LL 0 J m Z u LL 11L > 2 Z LL O a � 0 N0 } _ � z � Q J � � MM O W a z M� W C Lj C C w � p Z T z m _J U Ci C9 ch z - Lo 3 Q, LA a N ISSUED FOR: Z PERMIT z Q PROJECT NUMBER o 21020 z Q DATE z 5.5.21 W 2 ti DRAWING NUMBER u O Q z W A300 z LL z O U v t N n n M • i Pd ¢ C&K ARCHITECTS I INTERIORS Q architecture •Interior design •client services > AAC001629 m or • 4221 WEST BOY SCOUT BLVD., SUITE 150 TAMPA, FL 33607-5743 a 813.884,2000 " 280 WEST CENTRAL AVE. w _ WINTER HAVEN, FL 33880-2957 ¢ w 863.577.2054 0 ¢ a z w 0 w 2 w Q K w Z _ Z_ rr w W w rr 0 OQ Q N I' * ) , Q 0 i Z L �S' RAG Z Ca lL 0 z ¢ LL 0 N • Z [n Z 0. LLi 0 z Q ¢ 2 w O Z Y Z O Q y W 0. z W 0 w tr Z w Z_ w Q Z 2 J LL Z K J. w d W w m_ N Z 7 z 0. 0 rr w 0. Q O N � Z n. O, NN ii w 0 0 w az w _.J z LL a w Z 0 Z 0 = a N0 Q M ° z W- 0 Z Z W r1`00 w s o J - z CG J Q > i M u7 p, z 3 ¢ LO o ISSUED FOR; z PERMIT Z Q PROJECT NUMBER z 0 21020 - Q DATE 5.5.21 z DRAWING NUMBER v A301Z 0 z W Z z 0 f, h M \ EE �Sx 00 Cq M W a. C&K ARCHITECTS I INTERIORS - Q architecture•Interiordesign -clientservices U AAC001629 m 4221 WEST BOY SCOUT BLVD., SUITE 150 0 TAMPA, FL 33607-5743 ; z a 813.884.2000 280 WEST CENTRAL AVE. W _ WINTER HAVEN, FL 33880-2957 a w 863.577,2054 0 a a W z W a a W W O W z z 3 a 0 w w 0 LL o m o� LL;� o - o �s 8 \ Z LL Z a LL O W N LL. Z P m in z O U ui U Z a Q w z Y a Z O w Q W H LU �- Z cc LU � w w z_ w C;2 Z 0 LL z J > J LLJj i Z W LL w m N z • a z w 0 a -. Z Z w w O Z z W w Z 7 - ` (L w O w - ` CL W O - fV li > LL z _ i 0 W z Z C w - J z m 01 U')LO 3 a a ISSUED FOR: z PERMIT o Z a H PROJECT NUMBER Z C 21020 z DATE 5.5.21 LL DRAWING NUMBER w C z A302Q M• z W LL z C L i GEERL0 N A N T ES A. ALL CONCENTRATED LOADS APPLIED TO THE TRUSS SHALL II H BE INSTALLED WITHIN 6 OF THE TRUSS TR PANEL POINT AT IN THE CHORD TO WHICH THAT LOAD 15 BEING APPLIED A IS WHENEVER POSSIBLE. WHERE LOAD D T ANC E FROM PANEL STIFFENER E POINT EXCEEDS.6 WILL A WEBLLB REQUIRED CONNECTING THE POINT OF THE LOAD TO THE NEAREST PAENL POINT T THE PP A H 0 OSITE CHORD. _ UI I CONCENTRATED LOAD IS B JOIST STIFFENER REQUIRED F _ GREATER THAN 151# OR IS LOCATED THAN 6n FROM FT TRUSS 70P OR BOTTOM CHORD OF PANEL. SEE DETAIL 2. _ II 10 II , II II II II II II II ZoN 6 II I) z II II II II n 6 6 n 8 II II M A II O KEYNOTES, O R7 U—I II IS CERTIFIED MANUFACTURER'S ROOF OPENING SIZE PER F 7 1. URER — DRAWING. 247 3 II I I o n n I— _„ 2. 6 x 4 x 3/8 STEEL ANGEL(L.L.H,) x 0 8 LONG II �I (TYPICAL). dm0J14JLl1I L'.i' III DOOR AND FRA E TYPES DOOR SCHEDULE ARKS DOOR AND FRAMERENARKS, ELEV• VARIES CLG HEIGHT EE 5CHED. EE SCHED. EE SCHED. S E SCHEDU U..t N0,PTR51ZETYPE POOR FRAME DE A L GROUP REMARKS I. REPLACE KEYING HARDWARE. PROVIDE NEW CYLINDER - BEST LOCK 7-PIN; FINISH TO MATCH DOORS. LABE C�AS FINISH TYPE FINISH HEAD JAM5 SILL IOOA - EXISTING TO REMAIN - - - - - - - - - - 11 2. NEW PAINT FINISH ON EXTERIOR TO MATCH EXISTING. G , _ - LL, n n n w w w la CGI> G1uz a u O W w w w 1.0 ti.1 w w N IOOB 101 - _..................................._. - i i 1 3 0 X 7 0 X 13/4 _ ... _ _. I -6 7 - X 0 D3 _:_.:_ DI - _ ::..... - G I P3 _ BLK L AM EXTG F I P6 P 6: EXTG f/A320 EXTG 2/A320 5/A320 - C B 2 4 5 / / - _ 3. UN CUT 40 0 MECHANICAL DRAWINGS. - DER. T DOOR. REFER T E L DR G S SHEET A800 0FINISHES. SEE EET FOR b S NO 5 ON A30DEMOLITION SN 00 SH SEE NOTE 0 SHEET. DOOR ALL MEET THE MINIMUM REQUIREMENTS FOR HARDWARE LISTED. 103 � 1 1 I I 1 n 3 0 7 -/ X 0 X 13 4 D2 - P3 ' F I P 6 3/A320 /A3 0 4 2 D 4 104 i I I I n n 3 0 X 7 0 13/ X 4 D 2 P3 . FI P 6 3/A3 0 2 /A3 0 4 2 A 3 4 105 - i_ n �_ o _ 3 0 X 7 0 X 13/4o D2 - - P3 FI P6 3/A320 4/A320 _ A 3, 4 ELEV: 00I -0 FINISH FLR - D1 D2 D3 ELIASON CURTRON SERIES 30 RE WOOD EXTERIOR F 1 Io SOLID CO NA A RDW RE TYPES _ NEW DOOR HANDLES 0 BE LEVER TYPE; HARDWARE TOMATCH SATIN STAINLESS GROUP A . DOUBLE -ACTION ALUM CORE PAINTED HOLLOW METAL L 2n INTERIOR. SWINGING PAINTED _ G G DOOR P TED HOLLOW METAL W/BLACK LAMINATE FINISH F PAINTED. 1-1/2 PR. BUTT HINGES 6 R T PR EACH LEVER LOCKSE - RIVACY FUNCTION - 2 EACH KICKPLATES 2 1 EACH CLOSER EACH FLOOR STOP 5 3 EACH SILENCERS E 4 :. GROUP PER DOOR MANUFACTURERINCLUDING: 7 DOUBLE ACTION GRAVITY HINGES G G STAINLESS STEEL KICK PLATES _ GROUP 1/ L HINGES _ 2 PR G - _ 1 EACH EXIT DEVICE I EACH LOCKSET - ENTRANCE FUNCTION _ } ;a. I EACH KICK PLATE PUSH SIDE I EACH WEATHERSTRIP @ 14EAD t JAMBS ,1\ I EACH THRESHOLD WITH STOP ..... GROUP D 1-1/2 PR. BUTT HINGES EACH LEVER LOCKSET-STORAGE FUNCTION 1 EACH CLOSER 4 FRANE DETAIL 2 FRAME DETAIL ' I EACH DOOR HOLDER 3 EACH SILENCERS SCALE: 3" = I'-011 ` JAMB SCALE: 3" 1'-0" JAMB 0 GL SS TYPES TYPE GI 6 NON -RATED q" X 14" VISION PANEL WITH BLACK 20 y RUBBER MOLDING 17 :. 21 ENERAL NOTES I 13 :. A. GC TO PROVIDE BLOCKING WITHIN PARTITIONS AND CEILING AS NECESSARY FOR ALL NOTED AND SHOWN WALL/CEILING ACCESSORIES, FIXTURES MILLWORK AND EQUIPMENT OR WHERE a J 4 : _ NOTED IN THESE PLANS. N 4 a B, CORNER REINFORCEMENT FOR ALL NEW PARTITIONS SHALL BE US zi GYPSUM NO. 103 DURA BEAD OR EQUAL IN SINGLE LENGTHS. a 5 WALLBOARD EDGE TRIM SHALL BE USG 200-A OR 200-B OR 21 4 2 EQUAL. a 6 C. GC TO PROVIDE ALLOWANCE FOR INSULATING ALL EXISTING PIPES a a 6 AS REQUIRED. ANY EXPOSED PIPES SHALL BE PAINTED TO MATCH ADJACENT SURFACE D. PROVIDE ACCESS HATCHES 0 A NEW MEQUIPMENTWH F R ALL E EP ERE UL DETAIL REQUIRED. HATCH SHALL BE TRIMLESS FLUSH AND PAINTED TO 5 FRANE DETAIL 3 FRAME DETAIL I FRAME DETAIL MATCH ADJACENT SURFACE: N.T.S. 2 HOUR CMU DEMISING PARTITION HEAD - - _ SCALE: 3" = 1'-011. SILL LE LL " = SCALE 3 IIL. - _ 10 HEAD - - A : ,: " _ I11 SCALE: _ 3 10 HEAD O KEYNOTES O: 1. SCHEDULED PARTITION. REFER T0 FLOOR PLANFOR TYPES. 2. SCHEDULED DOOR FRAME. 3. FRTWOOD SHIM, AS REQUIRED.. 4. CONTINUOUS CAULK AT PERIMETER OF FRAME/WALL C CONN IONS ET . - 5. FRAME ANCHOR. 6. SCHEDULED DOOR. - 7. PROVIDE DOUBLE STUD AT JAMB OPENINGS. . 8. CEILING TYPE AS SCHEDULED. q. 5/8" GYPSUM BOARD. G R 10. CERTAINTEED PROROC MOISTURE AND MOLD RESISTANT GYPSUM OR EQUIVALENT. 11. BACKER ROD AND SEALANT.. 12. 2X4 FRT WOOD BLOCKING. 15 15 13. CONCRETE SLAB. 14. GALVANIZED METAL TRACK, MATCH STUD SIZE/GAUGE: 15. EXISTING STRUCTURE. 16. SCHEDULED BASE. 25 17. ANCHOR FRAME AS REQUIRED BY FLORIDA PRODUCT 1 11 _ 3-8 24 24 24 s SEE R.C.P. _ � ; SEE R.C.P. 18 APPROVAL_ 3-1/2" SOUND ATTENUATION BATT BETWEEN STUDS. 23 CEILING HT. CEILING HT. Iq. 3-5/8" 20 GAUGE METAL STUDS, 2411 O.C. WITH 27 26 38" AFF 42" AFF HORIZONTAL BRACING EVERY 4811 O.C., STAGGERED 34" AFF _ TOP OF WALL 34" AFF TOP OF - WALL 8 g BETWEEN STUDS AND A HORIZONTAL TOP BRACE. TOP OF WALL TOP OF WALL , 20. ANODIZED ALUMINUM THRESHOLDS IN U 0 D ET FULL BED F 22 1 12 27 12 25 12 25 I 12 18 SEALANT. Iq - 21. BOX HEADER. Iq 22. 3-5/8" 20GA. METAL STUDS 1611O.C. q i q i q i i q 10 q 10 23, 6 , 20GA. METAL STUDS, 16 O.C. _ 24. STAINLESS CAP OVER FTR WOOD BLOCKING / FINISH 14 - 14 14 14 14 DESIGNATION W10. REFER TO FINISH SCHEDULE. NOTE: 16 16 16 16 4 16 4 1 i VER FY DEPTH OF APPLIED FINISHES. OVERHANG TO 0 16 PREVENT RAW EDGES BEING EXPOSED TO VIEW. nA 4 i 4 4 - 25. TEMPERED LASS SNEEZE GUARD. SEE EQUIPMENT PLAN G I I ON A302, 0'-0" i VFIN.FLR. 0'-0° 0'-0" i 0'-0" 0'-0'I A.F.F. I " 0 -0 A.F.F. 26. 16G CUSTOM STEEL WORKCOUNTER CAP OVER KNEE WALL FIN.FLR. IN. F FLR. IN. F ..FLR. .;, FIN. FLR: , FIN. FLR. PROVIDED AND INSTALLED- BY FOOD SERVICE VENDOR. ,< 27. POWER/ DATA PORT.:.. P006 PARTITION TYPE P005 PARTITIONTYPE P004 PARTITION TYPE P003 .TYPE.:. P002 PARTITION TYPE P001 PARTITION TYPE SCALE: I " = I'-011 SCALE: I n = I'-0" SCALE: 1 " = 1'-0° SCALE: I " = 1'-011 SCALE: I " _ I'-011 SCALE " = I'-0" I C&K ARCHITECTS I INTERIORS a architecture•interiordesign - client services Y AAC001629 4221 WEST BOY 'SCOUTBLVD., SUITE 150 x TAMPA, FL 33607-5743 a 813.884.2000 c 280 WEST CENTRAL AVE. WINTER a HAVEN, FL 33880-2957 863.577.2054 c a a LL c Z LL a LL a - C Z Z 3 a c LL c LL O -ro a�J o', W Hl c m am LL Z a c v z Z a LL LL z a a LL Z Y a z O a LL y W a Z ne a W � LL LL LL z LL o z J Z LL J 1 J tL C } C S LL v ) Q' N Z J W _ C a w z I- (� C L1J w 0 O Q H w a GENERAL NOTES L 0 A. TABLES AND CHAIRS TO BE PURCHASED AND INSTALLED BY TENANT. SERVICE LINE CLG. B. SEE SHEET A302 FOR EQUIPMENT SCHEDULE. C. SEE SHEET A700 FOR REFLECTED CEILING PLAN. SEE R.C.P. D. SEE SHEET A800 FOR FINISHES. MTL W3A _ KEYNOTES --------------------- ---- ---- -------------------------------------- --- B.D. MTL.PANEL O E YN TES O 61-811 A.F.F. 7 6 I. BANQUETTE SEATING. REFER TO SECTION 6/A600. 2 600 - I W3A ---- ----- ----- -- ----- ---- 2. TENANT EQUIPMENT. 8 DINING RM CLG. 3. PROVIDE FINISH AT ALL EXPOSED SIDES OF LOW WALL AT 1 SEE R.C.P. J BANQUETTE. / W3A 4. DRINK LINE CHASE. SEE DETAIL 3/A700. COORDINATE FINISHED LOOP F 4 i LOCATION WITH TENANT EQUIPMENT. 0' -0" i 5 B2 5. T.V. I I I P4 OBLIQUE 6. MENU BOARDS: 2 Lam- J r 7. SNEEZE GUARD. __ i i - 2 WI tT 8. PAINT7 DETAIL -COUNTER 6 ELEVATION W6 N -� q. CORNER GUARD. NEW —SCALE: N.T.S. SCALE: 1/4" = 1'-011 10. CORRUGATED METAL PANELS. FINISHED FLOOR 11. FIRE EXTINGUISHER. 12. BANQUETTE SEAT/BACK: WATERFALL BLACK VINYL BI UPHOLSTERED FRONT, BACK EDGES AND KICK BASE EXPOSED TO VIEW WITH SELF WELT ON ENDS WITHOUT A SEAT APRON. DINING RM CLG. PROVIDE COIL SPRING CONSTRUCTION WITH NO HARD EDGES SEE R.C.P. AND UNIFORM SUPPORT. 5 DETAIL - POS COUNTER SCALE: N.T.S. I: 5/8" HIGH BY 1/32" RAISED LETTERING ( UNLESS NOTED OTHERWISE) 2. GRADE 2 BRAILLE POSITIONED DIRECTLY BELOW TEXT 3. 1/32" RAISED PICTOGRAM WITH 70% CONTRASTING BETWEEN BACKGROUND AND TEXT. FINISH TO BE EGGSHELL 4. COLOR TO BE BLUE BACKGROUND WITH WHITE LETTERS 5. SEE ELEVATION FOR MOUNTING INFORMATION 6d \ I1_6n � • • II DOOR w LU � a V V WOMEN MEN o TYP. MOUNTING ELEVATION F 7 DETAIL SCALE: N.T.S. SEE A320 P003 BI 21-011 SECTION I-o" SCALE 4 13, FOAM INNER CORE: MUST BE FLAME RETARDANT AND PASS CAL 117. TB-133. 14. STAINLESS CAP OVER FTR WOOD BLOCKING, FINISH 2 ELEVATION IDESIGNATION WIO. REFER TO FINISH SCHEDULE. NOTE: VERIFY SCALE: 1/4 I -0 DEPTH OF APPLIED FINISHES. OVERHANG TO PREVENT RAW EDGES BEING EXPOSED TO VIEW. 15. 16G CUSTOM STEEL WORKCOUNTER CAP OVER KNEE WALL PROVIDED AND INSTALLED BY FOOD SERVICE VENDOR. 4 ELEVATION T5 T6 SCALE: 1/411 = 1'-011 I T2 TI T2 T4 O I MTL A"700 DINING ROOM CLG. SEE R.C.P. I P4 , B.O.HEADER q'-0" A.F.F. O - - - -- - -- - - ---- I T2 T4 - - - - - - - - - - -- B.O. MTL.PANEL 8 I 6 8 6'-8" A.F.F. <I q 7 T2 TI T5 T6 POINT OF SALE q 34" A.F.F. FINISHED FLOOR qqr 0' -011 W6 BI 3 ELEVATION I ENLARGED PLAN SCALE 1/4 1'-011 SCALE 1/2 V-011 TOILET ACCESSORY SCHEDULE TOILET ACCESSORIES SHOWN AS THE BASIS OF DESIGN BE PROVIDED BY AND INSTALLED BY GC TO MEET THE MINIMUM REQUIREMENTS OF THE ADA 2020 EDITION. tl 181, X 3611 BOBRICK B-165-1836 54" 36"/42" GRAB BAR: 1-1/2" DIAMETER 55 'i / T2 T2 BOBRICK 6806 SERIES < T2 T7 O SINGLE GARMENT HOOK 4211 PIPE FLUSH VALVE I "ml T3 #642307 J-SN-C z / T5 PROTECTION TO 3611 I T4 LIQUID HAND SOAP DISPENSER / o INSIDE — O �� / DE OF WC O ECOLAB NEXA -SURFACE MTD. TOILET PAPER DISPENSER x p) 11 OX OLU X r OX -1 qll � a 1 a 1 aa = Cal 75 SAN JAMAR TWIN q" JBT R4000 �Q A---Q vw N m N rn Q ' i Q 6n T6 PAPER TOWEL DISPENSER / _ Q - O GP PRO VISTA DISPENSER #370052 / / PIPE PROTECTION /� - / / / // � / � T7 TRUEBRO SOFT GUARD P-TRAP COVER 82522 OR EQUAL MIRROR 36" It 42" GRAB PURSE NOOK AT HAND SOAP TOILET PAPER TOWEL BARS BACK OF DOOR DISPENSER PAPER DISPENSER DISPENSER TI T2 T3 T4 T5 T6 TOILET ROOM ACCESSORY MOUNTING HEIGHTS TOILET ROOM FIXTURE MOUNTING HEIGHTS SCALE: 1/4" = I'-0" SCALE: 1/4" = II-011 P c " M o o C&I< ARCHITECTS I INTERIORS Q architecture • interior design • client services AAC.001629 r m C 4221 WEST BOY SCOUT BLVD., SUITE 150 u TAMPA, FL 33607-5743 813.884.2000 w 280 WEST CENTRAL AVE. x WINTER HAVEN, FL 33880-2957 N 863.577.2054 J a w x LL Z a C w a w C Z Z 3 a T LL LL LL C y N Ik O. X LL' c0 J C _ u.' w `� a �1 C r Z Q LL C LL C Z C CC LY C Z } a C LL C z Q Q C Z Q 0 LL d LL y W a Z m W Q 0 L C z 11 C; ILL. C m J ; i a W Z Z N � Z C 0 LL a a C Z111,00z a LL 00 LL !Y C 0 Q LL C Z LL Z LU O LL W J � LU IV 0 Q } C Q Ly Zca LL r n V Q m z m c Z z LL LL o > Z m � o, z 3 a LO o ISSUED FOR: z PERMIT z a PROJECT NUMBER z 21020 Z 0 a DATE 5.5.21 z W DRAWING NUMBER U A600z 6 Z 0 0 U e,= ,o g cq C&K ARCHITECTS I INTERIORS Z Q architecture -interior design client services } - - AAC001629.--. m. 4221 WEST BOY SCOUT BLVD., SUITE 150 TAMPA, FL 33607-5743 a 813.884,2000 280 WEST CENTRAL AVE. _ WINTER HAVEN, FL 33880-2957 ` ¢ w 863.577:2054 0 ¢ . a z 0 w w 0 w z z 3 0 w `- � w 0 X 0 tt 4J O ` a z O; or L++ a 6-( 471 Q z (Q } z ¢ z O m SQ z - 0 U ui D Z w 0 z z 0 w Q N W d Z w a U w Lu m Q Q � Z w Z w Q z _ - LJL - Z - N J w > 2 0 Lu W m Z 0 Z O 0 < w a ¢ U (A,_/\ N� �f� Z w U V z w J � m � z w z L CL '^ w r w =0 o CL o LU r14 Q r LU Z 0 Cm LU Z J � a Z LL Im w LU 0 -rv. w s o > m Z 0 U /Q/nn V 0 z u7 N ISSUED FOR: z PERMIT a Q PROJECT NUMBER z O 21020 Z DATE 5.5.21 w z DRAWING NUMBER W A700 0 z J Q H Z W O W Z 0 - - -- - - 1- �. il,_I. AlLihi 1;L.11­11J111"Pkk1;1111lsi,I tV.Wll,titlII 7 O N 3t Q oo W a C&K ARCHITECTS INTERIORS ` a architecture -interior design -client services } - AAC001629 - m 4221 WEST BOY SCOUT BLVD., SUITE 150 x TAMPA, FL 33607-5743 a 813.884.2000 w - 280 WEST CENTRAL AVE. a WINTER HAVEN, FL 33880-2957 LL a 863.577.2054 c a a W x H } C Z LL LL a w Z >Z Q .. C V LL O � x 4`� Y co��yv �Q\ ♦;L •�cr ��,Q z mod. , a �n . •��'` .� (K , Ql z a z C C z a u: C z a Q 2 LL C Z LL, a W z O Q W N LU a Z W � a L W m Q � C C Z LL H Z W O z H C J , Z U_ O w - Lu w Z N z a Z w CL a 0 C 0 z Z w w a Q Z LLj ff....{O Z W a. ' A _ v , z .. = 0 w L W x 0 o = N 0 z a V Q o -C. I �. w z J w W CO Z z U W U. z m 0 Q C9 c9 M z o• U') o SO x ISSUED FOR: z Z PERMIT z a Z PROJECT NUMBER U O 21020' DATE 5.5.21 z DRAWING NUMBER u z z A800a aL z PART 1 -GENERAL 0.01 GENERAL SCOPE A. THIS PROJECT WILL REQUIRE INSTALLATION OF NEW HVAC SYSTEMS AS INDICATED. 1.01 GENERAL DOCUMENTS A. INSTALLATION SHALL BE IN ACCORDANCE WITH THE FLORIDA BUILDING CODE 7TH EDITION 2020 (EFFECTIVE 12131/2020), WHICH INCLUDES THE FLORIDA BUILDING CODE, MECHANICAL, FLORIDA BUILDING CODE, ENERGY CONSERVATION, AS WELL AS FLORIDA FIRE PREVENTION CODE, 7TH EDITION 2020 (EFFECTIVE 12/31/2020). ALL EQUIPMENT SHALL BE UL LISTED. B. THE MECHANICAL WORK SHALL INCLUDE FURNISHING ALL LABOR, EQUIPMENT, MATERIALS AND SERVICE NECESSARY FOR AND REASONABLY INCIDENTAL TO THE PROPER COMPLETION OF ALL MECHANICAL WORK SHOWN ON THE DRAWINGS AND AS SPECIFIED. ALL MATERIAL SHALL BE NEW. C. EACH PROSPECTIVE MECHANICAL CONTRACTOR SHALL EVALUATE THE SCOPE OF WORK THOROUGHLY PRIOR TO SUBMITTING A BID. D. SOME CONDUIT, PIPING, AND OTHER OBSTACLES MAY NEED TO BE RELOCATED AND SUCH RELOCATION SHOULD BE INCLUDED IN EACH PROSPECTIVE MECHANICAL CONTRACTOR'S BID. E. THIS ENGINEER IS NOT RESPONSIBLE FOR MATERIALS, METHODS, INSTALLATION, AND CONSTRUCTION WHICH DEVIATE FROM THESE CONSTRUCTION DOCUMENTS AND SPECIFICATIONS. 1.02 SUBMITTALS A. MATERIALS OR PRODUCTS SPECIFIED HEREIN AND/OR INDICATED ON DRAWINGS BY TRADE NAME, MANUFACTURER'S NAME OR CATALOG NUMBERS SHALL BE INTERPRETED AS ESTABLISHING A STANDARD OF QUALITY AND DESIGN. SUBSTITUTIONS MAY BE ALLOWED IF THEY MEE THE QUALITY STANDARDS AND DESIGN INTENT, UNLESS OTHERWISE NOTED. B. PRIOR TO STARTING THE PROJECT, THE MECHANICAL CONTRACTOR SHALL STUDY THE COMPLETE SET OF CONSTRUCTION DOCUMENTS AND COORDINATE WITH THE MANUFACTURER(S) AS REQUIRED TO PROVIDE EQUIPMENT SUBMITTALS TO SUBMIT TO THIS ENGINEER FOR REVIEW AND APPROVAL. THE EQUIPMENT SUBMITTALS SHALL INCLUDE DIMENSIONS, WEIGHTS, SPECIFIED ACCESSORIES AND REQUIRED CLEARANCES, AS WELL AS FAN CURVES, SOUND LEVELS, CONSTRUCTION DETAILS, WARRANTY INFORMATION, AND ALL OTHER RELEVANT DATA. C. IF ALTERNATES TO THE BASIS OF DESIGN ARE SUBMITTED, THE MECHANICAL CONTRACTOR SHALL PROVIDE A CLEAR, DETAILED SUMMARY IN THE SUBMITTALS OF THE DIFFERENCES BETWEEN THE SUBMITTED EQUIPMENT AND THE BASIS OF DESIGN. MECHANICAL ENGINEER OF RECORD MAY ACCEPT OR REJECT THE ALTERNATES. 1.03 SHOP DRAWINGS A. PRIOR TO STARTING THE PROJECT, THE MECHANICAL CONTRACTOR SHALL STUDY THE COMPLETE SET OF CONSTRUCTION DOCUMENTS AND COORDINATE WITH THE OTHER TRADES AS REQUIRED TO PROVIDE SHOP DRAWINGS TO SUBMIT TO MECHANICAL ENGINEER OF RECORD FOR APPROVAL. THE SHOP DRAWINGS MAY BE SUBMITTED AS HAND -DRAWN NOTES UPON A COPY OF THE CONSTRUCTION DOCUMENTS. THE CONSTRUCTION DOCUMENTS ARE DIAGRAMMATIC IN NATURE AND INTENDED SOLELY TO CLARIFY THE SCOPE OF WORK AND INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. THE CONSTRUCTION DOCUMENTS ARE NOT INTENDED TO ALERT THE MECHANICAL CONTRACTOR OF ALL OBSTACLES. THE SHOP DRAWINGS SHALL SHOW THE COORDINATION OF DUCTWORK AND MECHANICAL EQUIPMENT INSTALLATION WITH EXISTING AND NEW OBSTACLES INCLUDING; BUT NOT LIMITED TO, ELECTRICAL CONDUITS, FIRE PROTECTION PIPING, RAIN LEADERS, SANITARY DRAINS, STRUCTURAL MEMBERS, AND WATER PIPING, AS WELL AS THE MECHANICAL EQUIPMENT MANUFACTURERS' RECOMMENDED CLEARANCES. THE MECHANICAL CONTRACTOR SHALL ALSO SHOW THE EXISTING CONDITIONS ON THE SHOP DRAWINGS WHERE THE EXISTING CONDITIONS ARE DIFFERENT FROM THOSE SHOWN ON THE CONSTRUCTION DOCUMENTS. B. FURNISH SIX (6) COPIES OF SHOP DRAWINGS OF EQUIPMENT, MATERIALS AND SYSTEM LAYOUT TO GENERAL CONTRACTOR AND MECHANICAL ENGINEER OF RECORD PRIOR TO PURCHASING ANY EQUIPMENT AND BEGINNING WORK. 1.04 RECORD DRAWINGS A. AFTER COMPLETION OF ALL WORK, THE MECHANICAL CONTRACTOR SHALL PROVIDE THE GENERAL CONTRACTOR WITH AS BUILT RECORD DRAWINGS. MECHANICAL CONTRACTOR SHALL KEEP A RECORD CIF THE LOCATIONS OF ALL CONCEALED WORK AND UPON COMPLETION OF THE JOB, SHALL SUPPLY AS -BUILT DRAWINGS SHOWING ANY DEVIATION FROM THE ORIGINAL DRAWINGS. THESE DRAWINGS SHALL INDICATE DIMENSION OF BURIED UTILITY LINES FROM BUILDING WALLS. PART 2 - INSTALLATION 2.01 EQUIPMENT A. ALL MECHANICAL EQUIPMENT SHALL BE INSTALLED AS REQUIRED BY THE MANUFACTURER'S' INSTALLATION AND MAINTENANCE MANUALS. THOSE MANUALS WILL TYPICALLY PROVIDE MORE DETAIL THAN THE CONSTRUCTION DOCUMENTS. IF THERE IS A CONFLICT BETWEEN THE INSTALLATION AND MAINTENANCE MANUALS AND THE CONSTRUCTION DOCUMENTS, THEN THE MECHANICAL CONTRACTOR SHALL SUBMIT A REQUEST -FOR -INFORMATION TO MECHANICAL ENGINEER OF RECORD. B. VIBRATION ISOLATION: THE MECHANICAL CONTRACTOR SHALL PROVIDE VIBRATION ISOLATION AS RECOMMENDED BY THE MANUFACTURER(S) AND/OR REQUIRED BY MECHANICAL ENGINEER OF RECORD TO ENSURE QUIET OPERATION OF THE MECHANICAL EQUIPMENT. NO UNDUE VIBRATION OR SOUND SHALL BE TRANSMITTED TO THE STRUCTURE OR ANY OCCUPIED SPACES WITHIN THE STRUCTURE, C. FILTERS: THE MECHANICAL CONTRACTOR SHALL PROVIDE FILTER RACKS FOR THE MECHANICAL EQUIPMENT AS REQUIRED. THE FILTER RACKS SHALL BE INSTALLED SUCH THAT SUFFICIENT CLEARANCES ARE PROVIDED FOR MAINTENANCE AND SHALL BE SEALED AIRTIGHT. THE MECHANICAL CONTRACTOR SHALL PROVIDE A TOTAL OF THREE (3) COMPLETE SETS OF FILTERS FOR ALL MECHANICAL EQUIPMENT IN THE SIZE AND ARRANGEMENT RECOMMENDED BY THE MANUFACTURER. THE FILTERS SHALL PROVIDE ASHRAE FILTRATION EFFICIENCY AS SHOWN ON THE CONSTRUCTION DOCUMENTS OR 30% ASHRAE FILTRATION EFFICIENCY (MERV 6) IF NO HIGHER VALUE IS SPECIFIED. D. THE MECHANICAL CONTRACTOR SHALL PROVIDE ALL STARTERS, CONTACTORS, RELAYS, CONTROLS, AND ACCESSORIES NECESSARY TO PROVIDE A COMPLETE AND WORKING POWER AND CONTROL SYSTEM FOR THE MECHANICAL EQUIPMENT WITHIN THE SCOPE OF WORK. THE ELECTRICAL CONTRACTOR WILL PROVIDE ALL DISCONNECT SWITCHES, CONDUIT, AND WIRING FOR THE MECHANICAL EQUIPMENT WITHIN THE SCOPE OF WORK. ALL ELECTRICAL WORK SHALL COMPLY WITH THE REQUIREMENTS OF THE NATIONAL ELECTRIC CODE. THE MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROPER OPERATION OF THE COMPLETE SYSTEM AND SHALL ENSURE THAT WRING DIAGRAMS ARE PROVIDED TO THE GENERAL CONTRACTOR. NO WIRING OF ANY KIND SHALL BE EXPOSED IN FINISHED AREAS. E. HOUSEKEEPING PADS: THE GENERAL AND MECHANICAL CONTRACTORS SHALL PROVIDE A 4" HIGH CONCRETE HOUSEKEEPING PAD UNDER ALL MECHANICAL EQUIPMENT, UNLESS OTHERWISE NOTED ON THE CONSTRUCTION DOCUMENTS. THE HOUSEKEEPING PAD SHALL EXTEND 8" BEYOND THE MECHANICAL EQUIPMENT ON ALL SIDES. F. ELECTRIC DUCT HEATERS: ELECTRIC DUCT HEATERS SHALL BE UNDERWRITERS' LABORATORIES LISTED, BEAR THE SEAL OR MARK OF AN APPROVED TESTING AGENCY, AND BE EQUIPPED WITH AN APPROVED, AUTOMATICALLY RESETTING OUTLET AIR TEMPERATURE LIMIT CONTROL THAT WILL LIMIT THE OUTLET AIR TEMPERATURE TO NOT MORE THAN 200°F. THE MECHANICAL CONTRACTOR AND MANUFACTURER SHALL EQUIP THE ELECTRIC ELEMENTS OF THE HEATER WITH FUSIBLE LINKS OR A MANUAL RESET TEMPERATURE CONTROL THAT WILL PREVENT THE OUTLET AIR TEMPERATURE FROM EXCEEDING 250°F. EACH ELECTRIC DUCT HEATER SHALL BE INTERLOCKED WITH THE ASSOCIATED AIR HANDLER TO ENSURE ELECTRIC DUCT HEATER SHUTDOWN IN THE EVENT OF AN AIR HANDLER FAP FAILURE. LL 02 ACCESS PANELS, FIRE DAMPERS, AND FIRE/SMOKE DAMPERS A. THE GENERAL AND MECHANICAL CONTRACTORS SHALL PROVIDE ACCESS PANELS TO ALLOW ACCESS TO VOLUME DAMPERS ABOVE TURNING VANES. FIRE DAMPERS PLASTER OR GYPSUM CEILINGS, U FIRE/SMOKE DAMPERS, DUCT -MOUNTED SMOKE DETECTORS, AND WHERE REQUIRED FOR THE MAINTENANCE OF ALL MECHANICAL EQUIPMENT. ACCESS PANELS SHALL HAVE A FIRE RATING EQUAL TO THE PENETRATED ASSEMBLY, WITH A MINIMUM FIRE RATING OF ONE (1) HOUR. B. THE MECHANICAL CONTRACTOR SHALL ATTACH A BRIGHTLY -COLORED STRIP OF PLASTIC TAPE TO EVERY DUCT -MOUNTED ACCESS PANEL. THE STRIP SHALL BE OF SUFFICIENT LENGTH TO HANG A MINIMUM OF 12" BELOW THE BOTTOM OF THE ASSOCIATED DUCT. C. THE MECHANICAL CONTRACTOR SHALL PROVIDE A FIRE DAMPER AT EVERY DUCT PENETRATION OF A FIRE -RATED ASSEMBLY AND A FIRE/SMOKE DAMPER WITH A MINIMUM FIRE/SMOKE RATING OF TWO (2) HOURS AT EVERY DUCT PENETRATION OF A SMOKE ASSEMBLY OR CHASE. EACH FIREISMOKE DAMPER SHALL CLOSE AND THE ASSOCIATED AIR HANDLER SHALL SHUT DOWN IF EITHER OF THE AIR HANDLER'S OR THE SPACE'S SMOKE DETECTORS ARE ACTIVATED. D. THE MECHANICAL CONTRACTOR SHALL PROVIDE ADDITIONAL DUCTWORK AND PIPING SUPPORTS WITHIN EIGHTEEN (18) INCHES OF BOTH SIDES OF ALL FIRE -RATED ASSEMBLIES. DUCTWORK AND PIPING SHALL NOT BE SUPPORTED BY FIRE -RATED WALLS, BUT INSTEAD SHALL BE SUPPORTED BY THE BUILDING STRUCTURE. Q SMO E DETECTORS I A. DIVIDUAL AIR HANDLING SYSTEMS WITH A DESIGN CAPACITY OF MORE THAN 2000 CFM SHALL AUTOMATICALLY SHUT DOWN BY MEANS OF AN APPROVED SMOKE DETECTOR PLACED IN THE SUPPLY AIRFLOW AFTER ANY AIR FILTERS AND BEFORE ANY BRANCH CONNECTIONS IN THE SUPPLY DUCTWORK. B. MULTIPLE AIR HANDLING SYSTEMS SERVING THE SAME SPACE WITH A COMBINED DESIGN CAPACITY OF MORE THAN 2000 CFM SHALL AUTOMATICALLY SHUT DOWN BY MEANS OF AN APPROVED SMOKE DETECTOR PLACED IN THE SUPPLY AIRFLOW AFTER ANY AIR FILTERS AND BEFORE ANY BRANCH CONNECTIONS IN THE SUPPLY DUCTWORK, AS WELL AS AN APPROVED SMOKE DETECTOR PLACED IN THE RETURN AIRFLOW AFTER ANY BRANCH CONNECTIONS IN THE RETURN DUCTWORK AND BEFORE ANY EXHAUST OR OUTSIDE AIR CONNECTIONS. MORE INFORMATION IS AVAILABLE IN CHAPTER 4 OF NFPA 90A. C. THE MECHANICAL CONTRACTOR SHALL INCLUDE IN HIS/HER BID ALL COSTS ASSOCIATED WITH FURNISHING, INSTALLING, AND WIRING ALL SMOKE DETECTORS. THIS WILL INCLUDE, BUT NOT NECESSARILY BE LIMITED TO, MAKING DUCTWORK MODIFICATIONS AS REQUIRED BY THE MANUFACTURER'S INSTRUCTIONS. THE GENERAL OR MECHANICAL CONTRACTOR SHALL SUB -CONTRACT THE PURCHASE AND WIRING OF ALL SMOKE DETECTORS TO THE ELECTRICAL CONTRACTOR TO ENSURE THE SMOKE DETECTORS' COMPATIBILITY WITH THE FIRE ALARM SYSTEM. D. THE CONTRACTOR -PROVIDED INSTRUCTIONS TO THE OWNER FOR OPERATING AND MAINTAINING ALL MECHANICAL EQUIPMENT SHALL INCLUDE TESTING ALL AUTOMATIC SHUTDOWN DEVICES AT LEAST ONCE PER YEAR. SPECIAL INSTRUCTIONS SHALL BE GIVEN WITH REGARD TO ENSURING THAT SMOKE SENSING DEVICES ARE PROPERLY CLEANED AND CALIBRATED IN ACCORDANCE WITH THE MANUFACTURER'S REQUIREMENTS. MORE INFORMATION IS AVAILABLE IN CHAPTER 4 OF NFPA 90A. E. THE MECHANICAL AND ELECTRICAL CONTRACTORS SHALL PROVIDE EACH AIR HANDLING SYSTEM WITH A MINIMUM OF ONE (1) MANUALLY -OPERABLE MEANS TO SHUT DOWN ALL SUPPLY, RETURN, EXHAUST, AND OUTSIDE AIR FANS IN AN EMERGENCY. MORE INFORMATION IS AVAILABLE IN CHAPTER 6 OF NFPA 90A. 2.05 CONDENSATE DRAIN LINES A. REFER TO BASIC MATERIAL REQUIREMENTS ON THIS SHEET FOR G.D. MATERIAL SELECTIONS. B. THE MECHANICAL CONTRACTOR SHALL PROVIDE A P-TRAP AT EACH AIR HANDLER'S CONDENSATE DRAIN LINE CONNECTION. EACH CONDENSATE DRAIN LINE SHALL BE SLOPED DOWN A MINIMUM OF ONE -EIGHTH (118) INCH PER LINEAR FOOT TOWARD THE ASSOCIATED POINT OF DISCHARGE. C. THE DIAMETER OF THE CONDENSATE DRAIN LINE SHALL BE EQUAL TO OR GREATER THAN THE CONDENSATE DRAIN LINE CONNECTION. TO AVOID EXCESSIVE DIPS IN AND TO PREVENT ANY SHIFTING OF THE CONDENSATE DRAIN LINES, THE MECHANICAL CONTRACTOR SHALL PROVIDE SUPPORTS AT THE FOLLOWING INTERVALS: THREE (3) FEET FOR CONDENSATE DRAIN LINES CONSTRUCTED OF PVC, SIX (6) FEET FOR CONDENSATE DRAIN LINES CONSTRUCTED OF COPPER, AND TEN (10) FEET FOR CONDENSATE LINES CONSTRUCTED OF STEEL. CONDENSATE DRAIN LINE SUPPORTS SHALL BE FIXED SOLIDLY IN PLACE. D. CONDENSATE DRAIN LINES SHALL NOT BE ROUTED TO THE SANITARY SEWER SYSTEM OR TO SCUPPERS. E. THE MECHANICAL CONTRACTOR SHALL INSULATE EACH CONDENSATE DRAIN LINE WITH ONE-HALF (1/2) INCH ARMAFLEX WHEREVER THAT CONDENSATE DRAIN LINE IS ROUTED WITHIN THE STRUCTURE OR THE CONDENSATE MAY OTHERWISE CAUSE DAMAGE. F. THE MECHANICAL CONTRACTOR SHALL CLEARLY LABEL ALL CONDENSATE DRAIN LINES TO INDICATE CONTENT AND DIRECTION OF FLOW. 07 ROOF MOUNTED -EQUIPMENT THE MECHANICAL CONTRACTOR SHALL SET EACH ITEM OF ROOF -MOUNTED MECHANICAL EQUIPMENT ON A FACTORY CURB, CURB ADAPTER, OR ON A MINIMUM OF FOUR (4) PHP SYSTEMS/DESIGN MODEL RTU-20 EQUIPMENT SUPPORTS AT THE HEIGHT REQUIRED BY TABLE 1509.7 OF THE FLORIDA BUILDING CODE, UNLESS OTHERWISE NOTED ON THE CONSTRUCTION DOCUMENTS. > Pr hV �N�� s 2.08 DUCTWORK CONSTRUCTION A. THE SHEET METAL AND AIR CONDITIONING CONTRACTORS' NATIONAL ASSOCIATION'S "FIBROUS GLASS DUCT CONSTRUCTION STANDARDS" AND "HVAC DUCT CONSTRUCTION STANDARDS" SHALL BE CONSIDERED PART OF THE SPECIFICATIONS FOR THIS PROJECT, ANY WORK THAT DOES NOT COMPLY WITH THESE STANDARDS MAY BE REJECTED AT ANY TIME DURING THE PROJECT. B. REFER TO BASIC MATERIAL REQUIREMENTS ON THIS SHEET FOR DUCTWORK AND DUCT INSULATION MATERIAL SELECTIONS. C. ALL DUCT DIMENSIONS SHOWN ON THE CONSTRUCTION DOCUMENTS ARE INSIDE CLEAR DIMENSIONS. THE MECHANICAL CONTRACTOR SHALL PROVIDE FLEXIBLE CONNECTIONS BETWEEN EACH ITEM OF MECHANICAL EQUIPMENT AND ITS ASSOCIATED DUCT(S). ALL ITEMS OF THE HEATING, VENTILATION, AND AIR CONDITIONING SYSTEM INCLUDING, BUT NOT LIMITED TO, AIR HANDLERS, FANS, DUCTWORK, DIFFUSERS, AND GRILLES SHALL NOT BE SUPPORTED BY THE CEILING OR CEILING SUSPENSION SYSTEM, BUT INSTEAD SHALL BE SUPPORTED BY THE BUILDING STRUCTURE. D. ALL ELBOWS SHALL HAVE A ONE AND ONE-HALF (1.5) CENTERLINE RADIUS -TO -WIDTH OR RADIUS -TO -DEPTH RATIO OR SHALL BE CONSTRUCTED WITH SINGLE BLADE TURNING VANES. ANGULAR TAPERS SHALL BE LIMITED TO THIRTY (30) DEGREES FOR CONTRACTING TAPERS AND TWENTY (20) DEGREES FOR EXPANDING TAPERS. E. THE MAXIMUM LENGTH OF NEW FLEXIBLE DUCT SHALL BE 10'-0". FLEXIBLE DUCT SHALL BE INSTALLED AND SUPPORTED SO AS TO PREVENT THE USE OF EXCESS DUCT MATERIAL, PREVENT DISLOCATION OR DAMAGE, AND PREVENT CONSTRICTION OF THE DUCT BELOW THE RATED DUCT DIAMETER. FLEXIBLE DUCT BENDS SHALL MAINTAIN A CENTERLINE RADIUS OF NOT LESS THAN ONE AND ONE-HALF (1.5) DUCT DIAMETERS. SAGS SHALL NOT EXCEED ONE-HALF (0.5) INCH PER LINEAR FOOT OF FLEXIBLE DUCT. HANGERS, SADDLES, AND OTHER SUPPORTS SHALL HAVE A MINIMUM WIDTH OF ONE AND ONE-HALF (1.5) INCHES. THE MECHANICAL CONTRACTOR SHALL PROVIDE SUPPORT FOR NEW AND MODIFIED EXISTING FLEXIBLE DUCTWORK IN THE SCOPE OF WORK WITH A MAXIMUM SPACING OF 6-0", UNLESS OTHERWISE NOTED ON THE CONSTRUCTION DOCUMENTS OR AUTHORIZED BY MECHANICAL ENGINEER OF RECORD. F. SURFACES UPON WHICH CLOSURE OR SEALING PRODUCTS ARE TO BE APPLIED SHALL BE CLEAN AND DRY IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. ALL DUCTWORK SHALL BE SEALED WITH A NON -HARDENING, NON -MIGRATING MASTIC OR LIQUID ELASTIC SEALANT AS REQUIRED TO MEET THE FLORIDA ENERGY CONSERVATION CODE. THE MECHANICAL CONTRACTOR SHALL PROVIDE HOT -DIPPED GALVANIZED STEEL FASTENERS, ANCHORS, RODS, STRAPS. TRIM, AND ANGLES FOR INTERIOR DUCTWORK SUPPORTS. INTERIOR DUCTWORK SUPPORT SPACING SHALL NOT EXCEED 6-0". G. ALL DUCTWORK INSULATION. FITTINGS, COVERS, AND FINISHES SHALL HAVE A MAXIMUM FLAME SPREAD RATING OF 25, A MAXIMUM SMOKE DEVELOPMENT RATING OF 50, AND SHALL BE IN COMPLIANCE WITH NFPA 90A. PROVIDE MINIMUM OF 1/2" FIBERGLASS WITH FOIL/SCRIM VAPOR BARRIER ON THE BACK PAN OF ALL NEW AIR DEVICES. H. ALL OUTSIDE AIR INTAKES SHALL BE A MINIMUM OF 1U-0" FROM ANY EXHAUST OUTLET OR VENT PIPE (UNLESS THE VENT PIPE IS AT LEAST TWO (2) FEET ABOVE THE OUTSIDE AIR INTAKE). THE MECHANICAL CONTRACTOR SHALL PROVIDE SCREENS ON ALL OUTSIDE AIR INTAKES AND EXHAUST OUTLETS AT NO LESS THAN 1/4° BY 1/4 AND NO GREATER THAN 1/2" BY 1/2". THE MECHANICAL CONTRACTOR SHALL PROVIDE MOTORIZED DAMPERS IN ALL OUTSIDE AIR DUCTS. EACH MOTORIZED DAMPER SHALL BE CONTROLLED TO OPEN IN OCCUPIED MODE. I. THE MECHANICAL CONTRACTOR SHALL PROVIDE AN OPPOSED -BLADE VOLUME DAMPER FOR EVERY RECTANGULAR BRANCH AND OUTLET AND AT EVERY RECTANGULAR TAKE -OFF FOR A DIFFUSER OR GRILLE. (ROUND OR OVAL BRANCHES, OUTLETS, AND TAKE -OFFS FOR DIFFUSERS AND GRILLES SHALL BE PROVIDED WITH STANDARD VOLUME DAMPERS.) NOT ALL DAMPERS ARE SHOWN ON THE CONSTRUCTION DOCUMENTS. HOWEVER, DAMPERS ARE REQUIRED FOR EVERY BRANCH, OUTLET, AND TAKE -OFF. SOME DAMPERS MAY BE REQUIRED AFTER TRANSITIONS. J. THE MECHANICAL CONTRACTOR SHALL ATTACH A BRIGHTLY -COLORED STRIP OF PLASTIC TAPE TO EVERY VOLUME DAMPER, EXCEPT THOSE AT THE HEAD OF A DIFFUSER OR GRILLE. THE STRIP SHALL BE OF SUFFICIENT LENGTH TO HANG A MINIMUM OF 12" BELOW THE BOTTOM OF THE ASSOCIATED DUCT. K. THE MECHANICAL CONTRACTOR SHALL CLEARLY AND PERMANENTLY MARK EACH VOLUME DAMPER'S OPEN AND CLOSED POSITIONS. THE MECHANICAL CONTRACTOR SHALL PROVIDE A VOLUME DAMPER WITH A 2" STANDOFF WITH A LOCKING QUADRANT THAT IS 24 GAUGES OR 2 GAUGES HEAVIER. L. PROVIDE AND INSTALL "RUSKIN PRD-18" POSITIVE PRESSURE RELIEF DOORS IN SUPPLY DUCTWORK FOR ALL AIR HANDLER SYSTEMS WITH VAV BOXES, SMOKE DAMPERS OR FIRE DAMPERS, PROVIDE AND INSTALL "RUSKIN NRD-18 NEGATIVE PRESSURE RELIEF DOOR IN RETURN DUCTWORK FOR ALL AIR HANDLER SYSTEMS THAT HAVE MOTORIZED RETURN AIR DAMPERS, SMOKE DAMPERS OR FIRE DAMPERS. M. ALL DUCT SHALL MEET THE FOLLOWING CONSTRUCTION REQUIREMENTS: • SUPPLY DUCTWORK (UPSTREAM OF ANY VAV): 2.0 IWG POSITIVE STATIC PRESSURE AND VELOCITIES LESS THAN 2500 FPM. • SUPPLY DUCTWORK (DOWNSTREAM OF ANY VAV): 1.0 IWG POSITIVE STATIC PRESSURE AND VELOCITIES LESS THAN 1600 FPM. • ALL OTHER RETURN DUCTWORK: 1.0 IWG NEGATIVE STATIC PRESSURE AND VELOCITIES LESS THAN 1600 FPM. • ALL EXHAUST AND OUTSIDE AIR DUCTWORK: 1.0 IWG POSITIVE OR NEGATIVE STATIC PRESSURE AND VELOCITIES LESS THAN 1600 FPM. • ALL TRANSFER DUCTWORK: 0.5 IWG POSITIVE OR NEGATIVE STATIC PRESSURE AND VELOCITIES LESS THAN 500 FPM. • ANY OTHER DUCTWORK: REFER TO SMACNA`HVAC DUCT CONSTRUCTION STANDARDS". ALL RECTANGULAR METALLIC DUCTWORK SHALL BE SHOP FABRICATED OF GALVANIZED STEEL SHEETS, FOLLOWING ARE THE SMACNA RECOMMENDATIONS FOR GAUGES AND SEAMS. CONFORM TO THE RECOMMENDATIONS OF SMACNA AS TO SEAMS: JOINTS, CROSS BREAKS AND TRANSITIONS, ETC. RECTANGULAR STEEL DUCT GAGE DUCT WITH FLAT "S" SLIP WITH STANDING "S" SLIP DIAMETER IN INCHES ON 5' SPACING (GA) ON 5' SPACING (GA) 0-12 26 26 B 13 - 14 24 26 B 15 - 18 22 26 B 19 - 20 20 26 C 21 -26 18 26 C 27 - 28 16 26 C 29 - 30 16 26 D 31 - 36 - 24 D 37 - 42 - 24 E 43 - 60 22 G STANDING "S" SLIP SIZE B 1" x 26 GA C 1 "x 22 GA D 1-1/8" x 22 GA E 1-1/8" x 18 GA G 1-5/8" x 18 GA REFER TO SMACNA TABLES FOR REINFORCEMENT FOR DUCT LENGTHS OTHER THAN FIVE (5) FEET. ALL ROUND RIGID METAL DUCTWORK CAN BE PREFABRICATED OR SHOP FABRICATED, FOLLOWING ARE THE SMACNA RECOMMENDATIONS FOR GAUGES AND SEAMS. ELBOWS SHALL HAVE CENTERLINE RADIUS OF 1-112 TIMES DUCT DIAMETER. THE CONTRACTOR MAY PROVIDE EQUIVALENT ROUND OR RECTANGULAR DUCT AS CONDITIONS AND SPACE PERMIT. ROUND STEEL DUCT GAGE DUCT LONGITUDINAL SEAM DIAMETER SPIRAL S SEAM IN INCHES IN INCHES IN INCHES 3-8 28 28 9-14 28 26 15 - 26 26 24 27 - 36 24 22 37 - 50 22 20 51 - 60 20 18 61 - 84 18 16 ROUND ALUMINUM DUCT GAGE DUCT LONGITUDINAL DIAMETER SPIRAL SEAM SEAM IN INCHES IN INCHES IN INCHES 3 - 14 .025 .032 15 - 26 .032 .040 27 - 36 .040 .050 37 - 50 .050 .063 2.09 DUCT LEAKAGE PERFORMANCE A. FOR AIR CONDITIONING SYSTEMS OF FIFTEEN (15) TONS OR GREATER CAPACITY, AN INDEPENDENT TEST AND BALANCE CONTRACTOR SHALL PERFORM A DUCT LEAKAGE TEST IN COMPLIANCE WITH SMACNA'S "HVAC AIR DUCT LEAKAGE TEST MANUAL" TO VERIFY THE FUNCTION OF THE DESIGN AND THE WORKMANSHIP OF THE MECHANICAL CONTRACTOR. A DUCT LEAKAGE TEST USED TO CONFIRM DUCT LEAKAGE CLASS SHALL BE CONDUCTED AT THE PRESSURE FOR WHICH THE DUCT WAS DESIGNED AND CONSTRUCTED. B. DUCT CONSTRUCTION AND SEALING SYSTEMS SHALL MEET THE REQUIREMENTS OF THE FLORIDA ENERGY CONSERVATION CODE AND SMACNA'S "FIBROUS GLASS DUCT CONSTRUCTION STANDARDS" AND "HVAC DUCT CONSTRUCTION STANDARDS". IF THERE IS A CONFLICT AMONG THE STANDARDS, THEN THE MORE STRINGENT STANDARD SHALL BE ENFORCED. C. THE MECHANICAL CONTRACTOR SHALL SEAL ALL TRANSVERSE JOINTS, LONGITUDINAL SEAMS, AND DUCT WALL PENETRATIONS TO A MAXIMUM ALLOWABLE DUCT LEAKAGE CLASS OF THREE (3) CFM PER 100 SQUARE FEET OF DUCT AREA (1.5%) FOR ROUND DUCT AND SIX (6) CFM PER 100 SQUARE FEET OF DUCT AREA (3%) FOR ALL OTHER DUCT TYPES, UNLESS OTHERWISE NOTED ON THE CONSTRUCTION DOCUMENTS OR AUTHORIZED BY MECHANICAL ENGINEER OF RECORD. TRANSVERSE JOINTS ARE CONNECTIONS OF TWO DUCT OR FITTING ELEMENTS ORIENTED PERPENDICULAR TO THE DIRECTION OF THE AIRFLOW. LONGITUDINAL SEAMS ARE JOINTS ORIENTED IN THE DIRECTION OF THE AIRFLOW. DUCT WALL PENETRATIONS ARE OPENINGS MADE BY SCREWS, NOWSELF-SEALING FASTENERS, PIPES, TUBING, RODS, AND WIRE. ROUND AND FLAT -OVAL SPIRAL LOCK SEAMS NEED NOT BE SEALED PRIOR TO ASSEMBLY BUT SHALL BE COATED AFTER ASSEMBLY TO REDUCE LEAKAGE. ALL OTHER CONNECTIONS ARE CONSIDERED TRANSVERSE JOINTS INCLUDING, BUT NOT LIMITED TO, SPIN -INS, TAPS OR OTHER BRANCH CONNECTIONS, ACCESS DOOR FRAMES, AND DUCT CONNECTIONS TO EQUIPMENT. MORE INFORMATION IS AVAILABLE IN CHAPTER 35 OF ASHRAE'S "FUNDAMENTALS HANDBOOK D. ALL DUCTWORK SHALL BE INSPECTED BY MECHANICAL ENGINEER OF RECORD PRIOR TO BEING COVERED OR INSULATED. THE OWNER AND MECHANICAL ENGINEER OF RECORD SHALL. BE PRESENT DURING ALL DUCT LEAKAGE TESTING AND THE DUCTWORK SHALL BE TESTED AS INSTRUCTED BY MECHANICAL ENGINEER OF RECORD AND RETESTED IF REQUIRED BY MECHANICAL ENGINEER OF RECORD. IF ANY DISCREPANCIES ARE IDENTIFIED, THE DUCTWORK SHALL BE UNCOVERED AND REPAIRS SHALL BE MADE AT THE MECHANICAL CONTRACTOR'S EXPENSE. THE (MECHANICAL CONTRACTOR SHALL GIVE MECHANICAL ENGINEER OF RECORD TWO (2) WEEKS NOTICE BEFORE TESTING THE DUCTWORK. 2.10 AIR DEVICES A. THE MECHANICAL CONTRACTOR SHALL VERIFY THE LOCATIONS OF THE DIFFUSERS AND GRILLES AND SUBMIT A REQUEST -FOR -INFORMATION IF THERE IS A CONFLICT BETWEEN THE ARCHITECTURAL AND MECHANICAL PORTIONS OF THE CONSTRUCTION DOCUMENTS, THE MECHANICAL CONTRACTOR SHALL ALSO VERIFY THE TYPES OF CEILINGS IN THE SCOPE OF WORK PRIOR TO ORDERING DIFFUSERS AND GRILLES, FOR DIFFUSERS AND GRILLES LOCATED IN PLASTER OR GYPSUM CEILINGS, THE MECHANICAL CONTRACTOR SHALL PROVIDE METALAIRE MODEL TBPF / TITUS MODEL TRM PLASTER FRAMES, THE FRAMES MAY BE ALUMINUM IN NON -FIRE -RATED CEILINGS BUT MUST BE STEEL IN FIRE -RATED CEILINGS. THE MECHANICAL CONTRACTOR SHALL COORDINATE THE FINISH OF ALL DIFFUSERS AND GRILLES, EXPOSED DUCTWORK, GRAVITY VENTILATORS, LOUVERS, AND WALL CAPS WITH THE (ARCHITECT/OWNER). ALL VISIBLE EXTERIOR COMPONENTS (SUCH AS EXPOSED DUCTWORK AND LOUVERS) SHALL BE PROVIDED WITH A PAINT -GRIP FINISH. 2.11 CONTROLS A. THE MECHANICAL CONTRACTOR SHALL PROVIDE ALL CONTROLS AND SUB -CONTRACT TO THE ELECTRICAL CONTRACTOR ALL CONTROLS POWER AND TRANSFORMERS NOT IDENTIFIED IN THE ELECTRICAL PORTION OF THE CONSTRUCTION DOCUMENTS. B. THE MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR DETERMINING WHAT IS REQUIRED TO INCORPORATE NEW MECHANICAL EQUIPMENT AND CONTROLS INTO THE EXISTING CONTROL SYSTEM(S) AND INCLUDING ALL COSTS ASSOCIATED WITH INCORPORATING NEW MECHANICAL EQUIPMENT AND CONTROLS INTO THE EXISTING CONTROL SYSTEM(S) IN HISIHER BID. THE CONTROLS CONTRACTOR SHALL PROVIDE A COMPLETE DESCRIPTION OF THE ENTIRE CONTROL SYSTEM, INCLUDING SCHEMATIC DRAWINGS. C. THE MECHANICAL CONTRACTOR SHALL PROVIDE A HONEYWELL MODEL 7350 PROGRAMMABLE THERMOSTAT WITH A REMOTE SENSOR AND A LOCKABLE COVER FOR EACH NEW AND EXISTING AIR CONDITIONING SYSTEM. THE MECHANICAL CONTRACTOR SHALL ALSO PROVIDE ONE (1) PERSONAL DIGITAL ASSISTANT (PDA) AND HONEYWELL'S THERMOSTAT INTERFACE MODULE AND PROGRAMMING SOFTWARE. THE MECHANICAL CONTRACTOR SHALL COORDINATE THE INITIAL OCCUPANCY SCHEDULE(S) AND PROGRAMMING WITH THE OWNER AND PROVIDE TRAINING AS REQUIRED, ALL PROGRAMMING SHALL BE COMPLETED USING HONEYWELL'S THERMOSTAT PROGRAMMING SOFTWARE. D. EACH SENSOR SHALL BE INSTALLED AT 4'-6" ABOVE THE FINISHED FLOOR UNLESS OTHERWISE NOTED ON THE CONSTRUCTION DOCUMENTS. THE MECHANICAL CONTRACTOR SHALL COORDINATE THE EXACT LOCATION OF EACH SENSOR WITH THE OWNER AND SUBMIT THE PROPOSED LOCATION TO MECHANICAL ENGINEER OF RECORD FOR APPROVAL. THE MECHANICAL CONTRACTOR SHALL PROVIDE COORDINATION OF ALL SENSOR FINISHES WITH ROOM FINISHES AT NO ADDITIONAL COST TO THE OWNER. E. ALL EXHAUST AND OUTSIDE AIR FANS SHALL BE INTERLOCKED WITH THE AIR HANDLER SERVING THE ASSOCIATED SPACE. F. ALL 120-VOLT RESTROOM EXHAUST FANS WITH ELECTRICAL REQUIREMENTS OF UP TO 800 WATTS SHALL BE CONTROLLED BY AN OCCUPANCY SENSOR WITH A TIME DELAY. THE INITIAL TIME DELAY SHALL BE SET AT TWENTY (20) MINUTES. G. THE MECHANICAL CONTRACTOR SHALL PROVIDE A TIME CLOCK FOR ALL OUTDOOR AIR FANS. THE MECHANICAL CONTRACTOR SHALL COORDINATE THE INITIAL OCCUPANCY SCHEDULE(S) AND SETTINGS WITH THE OWNER AND PROVIDE TRAINING AS REQUIRED. PART 3 - EXECUTION 3.01 INSTALLATION A. OCOORDINATE WORK WITH OTHER TRADES AND EXISTING CONDITIONS PRIOR TO BEGINNING WORK, MECHANICAL CONTRACTOR SHALL PROVIDE ROUTING AND OFFSETS NECESSARY TO AVOID CONFLICT WITH STRUCTURE, FINISHES, AND WORK OF OTHER TRADES. 3.02 DISINFECTING OF POTABLE WATER SYSTEM A. THE SYSTEM SHALL BE FILLED WITH A SOLUTION CONTAINING 50 PARTS PER MILLION OF AVAILABLE CHLORINE AND ALL ALLOWED TO STAND 24 HOURS BEFORE FLUSHING AND RETURNING TO SERVICE. DISINFECTION PROCEDURE AND RESULT SHALL BE SUBJECT TO THE APPROVAL OF THE LOCAL MECHANICAL INSPECTOR. 3.03 TEST A. ALL MECHANICAL SYSTEMS SHALL BE TESTED IN ACCORDANCE WITH THE FLORIDA BUILDING CODE MECHANICAL. ALL TESTS SHALL BE APPROVED BY THE LOCAL MECHANICAL INSPECTOR AND SHALL BE OBSERVED BY A REPRESENTATIVE OF THE ARCHITECT. 3.04 SYSTEM IDENTIFICATION A. THE MECHANICAL CONTRACTOR SHALL PROVIDE IDENTIFICATION TAGS FOR ALL NEW EQUIPMENT, PIPING AND VALVES IN THE BUILDING. TAGS SHALL BE METAL WITH ENGRAVED UNIT/TAG NUMBER. 3.05 TESTING, ADJUSTING, BALANCING AND COMMISSIONING B. THE MECHANICAL CONTRACTOR SHALL ENSURE THAT THE MECHANICAL SYSTEMS ARE TESTED AND BALANCED. C. THE MECHANICAL CONTRACTOR SHALL PERFORM ALL TESTING, ADJUSTING, BALANCING, AND DATA RECORDING NECESSARY TO ESTABLISH THE CAPACITY AND QUALITY OF THE SYSTEMS AND CONFIRM THE SATISFACTORY COMPLETION OF ALL ASPECTS OF THE SCOPE OF WORK. THIS WILL INCLUDE ALL SYSTEMS WITHIN THE SCOPE OF WORK. ANYTIME FLOWS OR CALCULATIONS ARE SHOWN ON PLANS, DETAILS OR SCHEDULES, TEST & BALANCE IS REQUIRED. D. THE MECHANICAL CONTRACTOR SHALL ENSURE THAT THE BUILDING IS UNDER POSITIVE PRESSURE AT THE CONCLUSION OF THE TEST AND BALANCE PROCESS. IF THE BUILDING IS NOT UNDER POSITIVE PRESSURE AT THE CONCLUSION OF THE TEST AND BALANCE PROCESS, THEN THE TEST AND BALANCE AND MECHANICAL CONTRACTORS SHALL IMMEDIATELY AND WITHOUT DELAY NOTIFY THE ARCHITECT AND MECHANICAL ENGINEER OF RECORD. E. THE MECHANICAL CONTRACTOR SHALL, UPON COMPLETION OF ALL NECESSARY TESTING AND BALANCING AND AT LEAST ONE (1) WEEK PRIOR TO SUBSTANTIAL COMPLETION, SUBMIT THREE (3) BOUND COPIES OF THE TEST AND BALANCE AND COMMISSIONING REPORTS TO THE GENERAL CONTRACTOR AND MECHANICAL ENGINEER OF RECORD. F. THE MECHANICAL CONTRACTOR SHALL INCLUDE IN HIS/HER BID THE COST OF ANY SHEAVE CHANGES REQUIRED FOR REBALANCING THE SYSTEM. 3.06 SUBSTANTIAL AND FINAL COMPLETION A. THE MECHANICAL CONTRACTOR SHALL MAINTAIN A SET OF CONTINUOUSLY UPDATED, REPRODUCIBLE AS -BUILT DRAWINGS DURING CONSTRUCTION AND PROVIDE A COMPLETE SET OF THOSE DRAWINGS IN BOTH ELECTRONIC AND HARDCOPY FORMATS TO THE GENERAL CONTRACTOR AND MECHANICAL ENGINEER OF RECORD UPON FINAL COMPLETION. B. THE MECHANICAL CONTRACTOR SHALL CLEAN ALL COOLING AND HEATING COILS, CONDENSATE PANS, AND CONDENSATE DRAIN LINES PRIOR TO SUBSTANTIAL COMPLETION. THE MECHANICAL CONTRACTOR SHALL ALSO REPLACE ALL FILTERS AND BELTS PRIOR TO SUBSTANTIAL COMPLETION AND PROVIDE TWO (.3) COMPLETE REPLACEMENT SETS OF FILTERS AND (2) SETS OF BELTS FOR ALL MECHANICAL EQUIPMENT TO THE OWNER UPON FINAL COMPLETION. 3.07 WARRANTY A. THE MECHANICAL CONTRACTOR SHALL WARRANT ITS WORK TO BE FREE FROM DEFECTS IN MATERIALS AND WORKMANSHIP FOR A PERIOD OF ONE YEAR FROM FINAL ACCEPTANCE OF ALL WORK. B. THE MECHANICAL CONTRACTOR SHALL PROVIDE FIVE (5) BOUND COPIES OF ALL MECHANICAL. CONTRACTOR WARRANTIES, MANUFACTURER'S' WARRANTIES, PARTS LISTS, AND INSTALLATION AND MAINTENANCE MANUALS FOR ALL MECHANICAL EQUIPMENT, AS WELL AS INSTRUCTIONS FOR OPERATING AND MAINTAINING ALL MECHANICAL EQUIPMENT TO THE OWNER UPON FINAL COMPLETION. RIGID DUCT - DOUBLE LINE RIGID DUCT - SINGLE LINE i I FLEXIBLE DUCT INSULATED, SINGLE LINE FLEXIBLE DUCT - INSULATED SUPPLY AIR DUCT -SECTION RETURN AIR DUCT - SECTION DUCT TRANSITION - SINGLE LINE DUCT TRANSITION ELBOW WITH "AIRFOIL" TURNING VANES VD MANUAL VOLUME DAMPER (VD) SUPPLY AIR DIFFUSER RETURN AIR OR VENTILATION EXH. GRILLE EXHAUST AIR GRILLE OR CEILING MOUNTED EXHAUST FAN THERMOSTAT OR HUMIDISTAT - WALL MOUNTED $D DUCT SMOKE DETECTOR - --U - I 3/4"UNDERCUT -G -- 16X16 DOOR GRILLE SPIN -IN FITTING WITH VOLUME DAMPER BDD BACKDRAFT DAMPER j MOTORIZED DAMPEP XX FD=FIRE DAMPER, SD=SMOKE DAMPER FSD = FIRE/SMOKE DAMPER TO MATCH ASSEMBLY PENETRATION RATING (1 HR, 2-HR, ETC.), PROVIDE ACCESS PANEL FOR ACCESS CONNECTION - NEW TO EXISTING WORK. NEW LINE TYPE - - - - EXISTING LINE TYPE +r�a�r.Ran� M,:0.1 M2.1 MECHANICAL ra t • LAN MECHANICAL DEMO :. MECHANICAL PROPOSED D PLAN MECHANICAL Is i MECHANICAL D M9.1 MECHANICALDETAILS BASIC 1w%jU%0%;TWuAftwm%2r'%0 MATERIAL REQUIREMENTS, SUPPLY/RETURN: SHEET METAL X DUCTBOARD EXHAUST/OUTSIDE AIR: X SHEET METAL DUCTBOARD NOTES: X UTILIZE MATERIALS ABOVE UNLESS NOTED OTHERWISE ON PLANS X CONTRACTOR TO PROVIDE DEDUCTIVE COST ALTERNATE FOR USE OF DUCTBOARD BASHC . . MATERIAL REQUIREME1242TE11%jo CONDENSATE DRAIN: X SCHEDULE 40, PVC COPPER, TYPE L, W/ARMAFLEX INSULATION NOTES: X UTILIZE MATERIALS ABOVE UNLESS NOTED OTHERWISE ON PLANS BASIC INSWLATIOM MATERIAL e ON CONCEALED DUCTWORK: X FLEXIBLE FIBERGLASS FIBROUS DUCTBOARD ON EXPOSED DUCTWORK: FLEXIBLE FIBERGLASS X FIBROUS DUCTBOARD R-VALUE: X IN UNCONDITIONED SPACE, R-8 ALL OTHER DUCTWORK, R-4.2 NOTES: X UTILIZE MATERIALS ABOVE UNLESS NOTED OTHERWISE ON PLANS l' y: .'"em s s CK ARCHITECTS INTERIORS architecture. interior design• client services AAC001629 4221 WEST BOY SCOUT BLVD., SUITE 150 TAMPA, FL 33607-5743 813.884.2000 280 WEST CENTRAL AVE. WINTER HAVEN, FL 33880-2957 863.577.2054 21. O 1k 5/ 2021 ° Or TATE OF + 4/ ANAL _ T.. 0 LLj LLj Ca Cn z 0 z p I Z m _ ca / Z ci z J z S T z c} 2 _ z CL w ra LLj LAJ z 0 J m z ew3 � LID ua ISSUED FOR: T t Z a PROJECT NUMBER - Q DATE z DRAWING NUMBER m u z a a ■ 0 cs . . . . . . . . . . . . . . . . . . . . . . . s HA ............... C&K ARCHITECTS INTERIORS architecture. interior design• client services AAC001629 4221 WEST BOY SCOUT BLVD., SUITE 150 TAMPA, FL 33607-5743 813.884.2000 280 WEST CENTRAL AVE, WINTER HAVEN, FL 33880-2957 863.577.2054 A 5 4/2021 � TATE OF OR ONAL d 2 0 ua Ci �b 10 Lu MIS S Lu Cn 0 CA. co 0 Ce 0- Cn rLu 14 T 01 Cm F5 Lu < co Z V) 0 Lo 01 ISSUED FOR: PERMIT PROJECT NUMBER 210#20 tE DATE 5.5.21 DRAWING NUMBER mm2m I Orm"RhESSURIZATION CALCULATION ITEM EXHAUST (CFM) MAKE-UP (CFM) OA (CFM) HOOD 1 3150 2550 - RESTROOMS AND JANITOR 140 - - DISHWASHER HOOD NONE NONE NONE RTU-1 AND RTU-2 - - 940 TOTALS 3290 2550 940 TENANT PRESSURE = 940 OA FROM HVAC UNITS +2550 MAKE-UP - 3290 EXHAUST FROM HOODS AND RESTROOM = 200 CFM (POSITIVE) MATERIALS AND SHALL BE UL LISTED (UL2221). REFER TO DRAINING FOOD SERVICE PLANS (FS SERIES) FOR KITCHEN HOOD, EXHAUST AND SUPPLY EQUIPMENT DETAILS. PROVIDE A CLEANOUT AT ALL CHANGES OF DIRECTION OF THE GREASE EXHAUST DUCT. E 70 CF :m 0 2' 4' $' SCALE: 114" = 1'-O° _ • A ;ANdl � SCALE: NOT • SCALE MARK I EF-2 MANUFACTURER GREENHECK GREENHECK MODEL SP-13110 SP-13110 CFM 70 70 E.S.P. (IN. W.G.) 0.5 0.5 FAN TYPE CEILING CEILING MOTOR SIZE (WATTS OR BHP) 80 W 80 W ELECTRICAL (V/PH/HZ) 115/1/60 115/1/60 SOUND (SONES) 2 2 WEIGHT (LBS) 10 10 SERVICE WOMENS 104 MENS 105 QUANTITY 14 1 CONTROLS INTERLOCK W/LIGHT SWITCH INTERLOCK WILIGHT SWITCH NOTES - 1 2 3 4 5 6 1 PROVIDE FLEXIBLE CONNECTORS AT ALL DUCT CONNECTIONS TO FAN. 2 PROVIDE FAN WITH GRAVITY BACKDRAFT DAMPER. Ir 3 PROVIDE WITH FACTORY MOUNTED DISCONNECT SWITCH OPTION. 4 PROVIDE FAN WITH SPEED CONTROLLER. MOUNT SPEED CONTROLLER IN 2X4 METALLIC BOX ADJACENT TO FAN IN CEILING. TEST AND BALANCE CONTRACTORS SHALL ADJUST FAN PERFORMANCE THROUGH USE OF SPEED CONTROLLER. 5 PROVIDE FAN WITH ADJUSTABLE TIME DELAY RELAY FOR FAN TO CONTINUE TO OPERATE WHEN SWITCH IS OPENED, 6 PROVIDE WITH CFL LIGHT OPTION. MARK FACE SIZE NECK SIZE MATERIAL SD-1 24X24 6" O ALUMINUM ACCESSORIES FINISH - MANUFACTURER AND MODEL TITUS-TMS-AA NOTES 000 SD-2 24X24 8110 ALUMINUM - TITUS-TMS-AA 3 000 SD-3 24X24 10"0 ALUMINUM - - TITUS-TMS-AA 000 SD-4 24X24 12"0 ALUMINUM - - TITUS-TMS-AA 000 SD-5 24X24 14"0 ALUMINUM - - TITUS-TMS-AA 3 000 SD-S1 12X12 61'0 ALUMINUM - - TITUS-TMS-AA 3 000 EG-1 24X24 22X22 ALUMINUM - - TITUS-50F 3 RG-1 24X24 22X22 ALUMINUM - - TITUS-50F 00 TG-1 24X24 22X22 ALUMINUM - - TITUS-60F 02 NOTES 1 FLEX DUCT SIZE TO MATCH NECK SIZE. MINIMUM LENGTH OF FLEX SHALL BE 6'-0" TO MAXIMUM LENGTH OF 10`-01' , BALANCE OF DUCT SHOWN ON PLAN SHALL BE RIGID STEEL DUCT SAME SIZE AS NECK SIZE, EXTERNALLY INSULATED. 2 PROVIDE RUNOUT BRANCH DUCT TO AIR DEVICE SAME SIZE AS AIR DEVICE NECK UNLESS OTHERWISE NOTED ON PLANS. PROVIDE O.B.D. MODEL # AG-15-AA FOR AIR DEVICES IN HARD CEILING. 401 3 COORDINATE COLOR AND FINISH PER ARCH. DRAWINGS, REFER TO SHEET A100 NOTE "F, SUMMARYAIR SYSTEM SIZING FOR 3 SYSTEM SIZING SUMMARY FOO ROOFTOP UNIT SCHEDULE MARK - RTU-1 RTU-2 MANUFACTURER - LENNOX LENNOX MODEL _ KCB060S4B KCB090S4B TOTAL COOLING CAPACITY BTUH 61,800 93,600 SENSIBLE CAPACITY BTUH 41,100 64,500 -- SUPPLY AIR CFM _ ------.....__ _...._......_.----- 1750 2625 OUTSIDE AIR CFM _..... _ ._ _._..... _ ....... _ ._------------------ 375 565 ENTERING AIR TEMPERATURES DB/WB:F _._.._._---------__-_-- 76.6/66.8 78.6/66.8 ------------...._ LEAVING AIR TEMPERATURES __ ____ DB/WB:F _----- ----- ___-------------_.__. ..__ 55.8/54.9 54.9/54.8 E.S.P. IN. W.G. 0.5 0.75 _._-._._...._........._-___......... .__.._--------_...-- ELECTRIC HEAT KW 11.3 16.9 ELECTRICAL CHARACTERISTICS V/PH/HZ ------------------- ---- 208/3/60 208/3/60 MCA --------............_----- A ------ --- _.__....__.....__.________... 45.0 69.0 MOCP A 45 70 - SEER/EER _ 14.0 SEER 12.9 EER WEIGHT LBS 840 1235 NOTES 3 4 5 1 2 3 4 5 NOTES 1 UNIT CONTROL SHALL BE BASED ON SPACE TEMPERATURE AND UNIT SHALL BE CAPABLE OF HUMIDITY CONTROL. PROVIDE WITH HOT GAS REHEAT COIL OPTION. UNLESS VALUE ENGINEERED BY THE OWNER 2 PROVIDE GALVANIZED STEEL FILTER FRAMES AND MEDIA IN UNIT FILTER WITH MEDIA. FRAMES SHALL BE PRE -MANUFACTURED (NOT FIELD FABRICATED), FILTER SHALL BE MERV 8. PROVIDE HIGH EFFICIENCY MODEL WITH FACTORY ROOF CURB, OUTSIDE AIR INTAKE WITH 3 MOTORIZED DAMPER AND BIRD SCREEN AND THRU-THE BASE ELECTRICAL CONNECTION. PROVIDE WITH FACTORY THERMOSTAT WITH REMOTE SENSOR. UNIT SHALL CYCLE 4 COOLING/HEATING FROM THEIR THERMOSTAT OR SENSOR. COORDINATE T-STAT & SENSOR LOCATIONS WITH OWNER PRIOR TO INSTALLATION. PROVIDE WITH FACTORY INSTALLED ELECTRIC HEATER, SINGLE POINT POWER CONNECTION AND 5 FACTORY DISCONNECT. DUAL POWER WILL NOT BE ACCEPTED. r . r I r a► I [ a E Air System Information Air System Information 1. Summary Air System Name RTU-1 Number of zones 1 Air System Name RTU-2 Number of zones 1 Ventilation Sizing Method ASHRAE Std 62.1-2010 Equipment Class PKG ROOF Floor Area 804.0 ft2 Equipment Class PKG ROOF Floor Area 779.0 ft2 Design Condition Cooling operation Air System Type--------------SZCAV Location .___.. ..._.....----Tampa, Florida Air System Type -------------------_ .... _.SZCAV Location -----------Tampa, Florida Occupant Diversity (D) _- _. __._. _ _....._... - __--- ---_ 1.000 Uncorrected Outdoor Air Intake (Vou) 263 CFM System Ventilation Efficiency (Ev) 0.983 Sizing Calculation Information Sizing Calculation Information Outdoor Air Intake (Vat) _____- _ 267 CFM _......___ Calculation Months Jan to Dec Zone CFM Sizing _ Sum of space airflow rates Calculation Months Jan to Dec Zone CFM Sizing _ Sum of space airflow rates Sizing Data Calculated Space CFM Sizing _Individual peak space loads Sizing Data Calculated Space CFM Sizing _Individual peak space loads 2. Space Ventilation Analysis Time People Breathing Central Cooling Coil Sizing Data Central Cooling Coil Sizing Data Space Floor Area Outdoor Averaged Outdoor Air Air Space Zone Outdoor Space Total coil load Tons Load occurs at Jun 1500 Total coil load Tons Load occurs at Jun 1500 Supply Air Area Air Rate Occupancy Rate Distribution Outdoor Air. Air Ventilation -----------------------..._4.8 Total coil load 57.5 MBH - -------- CA DB / WB 89.0 180.0 °F .- --------- --- ____ ------.._.__------_._.._..7.1 Total coil load 85.6 MBH --------._ CA DB / WB 89.0 180.0 °F CFM ft2 CFM/ft2 (Occupants) CFM/ erson Effectiveness CFM CFNI Efficienc Sensible coil load 37.0 MBH Entering DB / WB 78.2 / 67.7 °F Sensible coil load 58.1 MBH Entering DB ! WB 77.0 / 66.3 °F Zone Name / Space Name Mult. (Vpz) (Az) (Ra) (PZ) (Rp) (Ez) (Voz) (Vbz) (Evz) Coil CFM at Jun 1500 _-.-_...._-.._ 1638 CFM Leaving DB / WB ... -------------- _ _.57.3 156.4 °F Coil CFM at Jun 1500-------- --- ------------ .......... 2610 CFM Leaving DB I WB .___._.._....__ ------ _--- 56.3 / 55.4 °F Zone 1 Max block CFM 1638 CFM Coil ADP 55.0 °F Max block CFM 2610 CFM Coil ADP 54.0 °F CORRIDOR 1 216 168.0 0.06 0.0 0.00 1.00 10 10 1,114 Sum of peak zone CFM 1638 CFM Bypass Factor 0A00 Sum of peak zone CFM 2610 CFM Bypass Factor 0A00 DINING AREA 1 1387 619.0 0.18 18.01 7.50 1.00 246 246 0.983 Sensible heat ratio 0.643 Resulting RH 55 % Sensible heat ratio .__._ 0.679 Resulting RH _ 56 % fe/Ton 167.9 Design supply temp. 56.0 OF ft2/Ton 109.2 Design supply temp. 58.0 OF OFFICE 1 35 17.0 OA6 1.0 5.00 1.00 61 6 0.987 BTU/(hr-ft2) 71.5 Zone T-stat Check 1 of 1 OK BTU/(hr ft2) 109.9 Zone T-stat Check 1 of 1 OK Totals (incl. Space Multipliers) 1638 263 0.983 Water flour @ 10.0 OF rise NIA Max zone temperature deviation _ 0.0 OF Water flow @ 10.0 OF rise N/A Max zone temperature deviation 0.0 OF Central Heating Coil Sizing Data Central Heating Coil Sizing Data Max coil load 23.8 MBH Load occurs at Des Htg Max coil load 24,6 MBH Load occurs at Des Htg Coil CFM at Des Htg 1638 CFM BTU/(hr-ft2) 29.5 Coil CFM at Des Htg 2610 CFM BTU/(hr-ft2) 31.6 Max coil CFM 1638 CFM Ent. DB / Lvg DB---_-_------._63.5 i 77.Q °F Max coil CFM-___-.-- 2610 CFM Ent. DB / Lvg DB __67.9 176.6 °F Water flow @ 20.0 OF drop _ N/A Water flow @ 20.0 OF drop . NIA 1. Summary Supply Fan Sizing Data Supply Fan Sizing Data Ventilation Sizing Method .__ ASHRAE Std 62.1-2010 Actual max CFM 1638 CFM Fan motor BHP 0.00 BHP Actual max CFM 2610 CFM Fan motor BHP 0.00 BHP Design Condition Heating operation Standard CFM _.1637 CFM Fan motor kW 0.00 kW Standard CFM 2609 CFM Fan motor kW 0.00 kW Occupant Diversity (D) 1.000 Actual max CFM/ft2 2.04 CFM/ftz Fan static - 0.00 in wg Actual max CFM/ft2 3.35 CFI Fan static 0.00 in wg Uncorrected Outdoor Air Intake (Vou) ----_. ----. 138 CFM __.- System Ventilation Efficiency (Ev) 0.920 Outdoor Air Intake (Vot) 150 CFM Outdoor Ventilation Air Data Outdoor Ventilation Air Data Design airflow CFM 267 CFM CFM/person 14.06 CFM/person Design airflow CFM 150 CFM CFM/person 25.07 CFM/person. S ace Ventilation Analysis CFM/ft2 CFMIft2 CFM/ft2 0.19 CFM/ft2 Time People - _ Breathing i Space Floor Area Outdoor Averaged Outdoor Air Air Space Zone Outdoor Space _I Supply Air (CFM) Area ft2 Air Rate CFM/ft2 Occupancy (Occupants) Rate CFM/ arson Distribution Effectiveness Outdoor Air l^ CFM- Air CFM Ventilation Efficienc Zone Name i Space Name Mult. (Vpz) (Az) (Ra) (Pz) (Rp) (Ez) (Vo"oz) I (Vbz) (Evz) Zone 1 ! SERVICE 1 690 485.01 0.12 2.0 7.50 0.80 91 73 0.920 KITCHEN 1 1920 294,01 0.12 4.0 7.50 0-80 82 65 1.011 Totals (incl. Space Multipliers) 2610 LL138 Q.920 SCALE: NOT TO SCALE I ULui d YC d d Lily - J fld7 't00 1 ! UZI MAX EXHAUST PLENUM HOOD CONFIG TOTAL RISER(S) HOOD APPLIANCE DESIGN TOTAL HOOD NO TAG MODEL M NUFACTUR R LENGTH COOKING TYPE DUTY CFM/FT EXH CFM SUPPLY END TO CONSTRUCTION ROW WIDTH LENG HEIGHT DIA CFM VEL SP CFM END 5424 600 4" 14" 1575 1473 -0.395" 430 SS 1 KH-1 ECON-AIR 14' 0" I HEAVY 225 3150 2550 ALONE ALONE 4" 14" 1575 1473 -0.395" EX-2-PSP-F DEG WHERE EXPOSED HOOOD TAG I TYPE QTYJ HEIGHT I LENGTH I EFFICIENCY @ 7 MICRONS IQTY 1 1 KH-1 I SS BAFFLE WITH HANDLES 1 10 1 16" 1 16" 30% I 7 wnnn nPT7nAPIZ HOOD NO TAG OPTION 1 KH-1 FIELD WRAPPER 18.00" HIGH FRONT, LEFT, RIGHT. BACKSPLASH 80.00" HIGH X 180.00" LONG 430 SS VERTICAL. RISER SENSOR INSTALL 31N DBL. HOOD NO TAG POS LENGTH WIDTH HEIGHT TYPE RISER(S) WIDTH LENG DIA CFM SP 1 KH-1 Front 1801, 16" 6" MUA 12" 28" 849 0.230" MUA 12" 28" 849 0.230" MUA 12" 28" 849 0.230" I FIRE HOOD FIRE SYSTEM ELECTRICAL SWITCHES TYPE WIRE LOCATION SIZE SYSTEM HANGING GUARD TYPE SIZE MODEL # QUANTITY PIPING `,HEIGHT 1 LIGHT L55 SERIES E26 NO RIGHT 12"x54"x24" ANSUL R102 3.0/3.0 SC-321110FP YES 916 LBS 1 FAN FAN MOTOR DISCHARGE WEIGHT UNIT TAG QTY FAN UNIT MODEL # MANUFACTURER CFM ESP RPM ENCL HP BHP PHASE VOLT FLA VELOCITY (LBS) SONES NO 1 KEF-1 1 EABDU15 ECON-AIR 1575 1.000 1195 ODP 0.750 0.4880 3 208 2.5 498 FPM 122 12.8 2 KEF-2 1 EABDU15 ECON-AIR 1575 1.000 1195 ODP 0.750 0.4880 3 208 2.5 498 FPM 122 12.8 MUA FAN INFORMATION - JOB4 FAN UNIT TAG CITY FAN UNIT MODEL # NO 3 KSF-1 1 EA-A1-G10 k'AAT eiPIPMAT.C' 7199 BLOWER HOUSING MIN DESIGN ESP RPM MOTOR WEIGHT HP BHP PHASE VOLT FLA MCA MOCIP SONES CFM CFM ENCL (LBS) G10 Al 2550 0.500 913 ODP 1.500 0.8780 3 208 4.6 5.8A 15A 245 19.8 FAN UNIT TAG QTY DESCRIPTION NO 1 GREASE BOX. 1 KEF-1 2 YEAR PARTS WARRANTY. 1 1 1 GREASE BOX. 2 KEF-2 12 YEAR PARTS WARRANTY. 1 1 I GRAVITY BACKDRAFT DAMPER FOR SIZE 1 HOUSING. 3 KSF-1 12 YEAR PARTS WARRANTY. 1 FA AT A rrF,S'.(Zf)RTPs..C' FAN UNIT TAG NO EXHAUST SUPPLY GREASE CUP GRAVITY DAMPER WALL MOUNT SIDE DISCHARGE GRAVITY DAMPER MOTORIZED DAMPER WALL MOUNT 1 KEF-1 YES 2 KEF-2 YES 3 KSF-1 YES NO O N TAG WEIGHT ITEM SIZE 1 # 1 KEF-1 41 LBS CURB 23.000"W X 23.000"L X 24.000"H VENTED HINGED. 2 # 2 KEF-2 41 LBS CURB 23.000"W X 23.000"L X 24.000"H VENTED HINGED. 3 # 3 KSF-1 34 LBS CURB 21.000"W X 21.000"L X 24.000"H . FAN #1 EABDUI5 -EXHAUST FAN (KEF-1) DRAIN. FAN #2 EABDU15 - EXHAUST FAN (KEF-2) FEATURES - ROOF MOUNTED FANS. -RESTAURANT MODEL. UL705 AND UL762 AND ULC-S645. -AMCA SOUND AND AIR CERTIFIED. -WIRING FROM MOTOR TO DISCONNECT SWITCH NEMA 3R SAFETY DISCONNECT SWITCH. - HIGH HEAT OPERATION 3007 (149'C). - GREASE CLASSIFICATION TESTING. NORMAL TEIAPERATUR.E TEST EXHAUST FAN MUST OPERATE CONTINUOUSLY WHILE EXHAUSTING AIR AT 300-F (149-C) UNTIL ALL FAN PARTS HAVE REACHED THERMAL EQUILIBRIUM, AND WITHOUT ANY DETERIORAn NG EFFECTS TO THE FAN WHICH WOULD CAUSE UNSAFE OPERATION. ABNORMAL FLARE-UP TEST EXHAUST FAN MUST OPERATE CONTINUOUSLY WHILE EXHAUSTING BURNING GREASE VAPORS AT 60WF (316'C) FOR A PERIOD OF 15 MINUTES WITHOUT THE FAN BECOMING DAMAGED TO ANY EXTENT THAT COULD CAUSE AN UNSAFE CONDI I"ION. OPTIONS GREASE BOX. 2 YEAR PARTS WARRANTY. FEATURES 2 VENTED CURB. ".0 GAUGE >TEEL ROOF OPENING 22112 DIMENSIONS. 22 1!2 PITCHED CURBS ARE AVAILABLE FOR PITCHED ROOFS. 5° SPECIFY PITCH: 12" EXAMPLE: 7/12 PITCH = 30` SLOPE. BLOWER DI WIRING. IT! OF THE. ENSURETHAT FROM AND CO' LOCAL L55 SERIES E26 CANOPY LIGHT FIXTURE - 'LEAR THERMAL 5 FIXTURE) ) WRAPPER 18.00"HIGH HOOD OPTIONS TABLE;. HING PLATES. .Y RISER'011TH 4E DAMPER ?,o OPEN STAINLESS EL PERFORATED PANEL. C GOl FIRE SUPPRESSION SYSTEM d 0 FAN #3 EA-A1-G10 - SUPPLY FAN (KSF-1) 1. UNTEMPERED SUPPLY UNIT WITH 10" BLOWER IN SIZE #1 HOUSING. 2. INTAKE HOOD WITH EZ FILTERS. 3. DOWN DISCHARGE - AIR FLOW RIGHT -> LEFT. 4. GRAVITY BACK DRAFT DAMPER, 16" WIDE X 18" HIGH, STANDARD GALVANIZED CONSTRUCTION, 1 1/4" REAR FLANGE, FOR SIZE 1 UNTEMPERED FAN HOUSING (5181). 6.2 YEAR PARTS WARRANTY. *NOTE: SUPPLY DUCT MUST BE INSTALLED TO MEET SMACNA STANDARDS. A MINIMUM STRAIGHT DUCT LENGTH MUST BE MAINTAINED DOWNSTREAM OF UNIT DISCHARGE AS OUTLINED IN AMCA PUBLICATION 201, WHEN USING RECTANGULAR DUCTWORK, ELBOWS MUST BE RADIUS THROAT, RADIUS BACK WITH TURNING VANES. FLEXIBLE DUCTWORK AND SQUARE THROAT/SQUARE BACK ELBOWS SHOULD NOT BE USED. ANY TRANSITION AND/OR TURNS IN THE DUCTWORK WILL CAUSE SYSTEM EFFECT. SYSTEM EFFECT WILL DRASTICALLY INCREASE STATIC PRESSURE AND REDUCE AIRFLOW. DO NOT RELY ON UNIT TO SUPPORT DUCT IN ANY WAY. FAILURE TO PROPERLY SIZE DUCTWORK MAY CAUSE SYSTEM EFFECTS AND REDUCE PERFORMANCE OF THE EQUIPMENT. SUGGESTED STRAIGHT DUCT SIZE IS 14" X 14". - ROOF MOUNTED FANS. -RESTAURANT MODEL. X - UL705 AND UL762 AND ULC-S645. Furnish Single -wall, factory built, grease duct for use with Type I kitchen hoods, which conforms to the requirements of NFPA-96. Products shall be ETL listed to UL-1978 and -AMCA SOUND AND AIR CERTIFIED. VENTED LIFTING LUG. ° ® CAN/ULC-S662 for venting air and grease vapors from commercial cooking operations as described in NFPA-96. -WIRING FROM MOTOR TO DISCONNECT SWITCH. CURB. -NEMA 3R SAFETY DISCONNECT SWITCH. AIRFLOW. The duct wall shall be constructed of .036 or .047 thick type stainless steel and be available in diameters 8" through 24". All supports, fan adapters, hood connections, fittings and - HIGH HEAT OPERATION 300°F (149'C). 24„ expansion joints required to install grease duct shall be included. - GREASE CLASSIFICATION TESTING. SERVICE AIRFLOW. DISCONNECT -- I SWITCH. Roof penetrations shall comply with listed clearance to combustibles, see "Clearance to Combustibles" guide for details. The grease duct will terminate at the fan adapter plate, NORMAL TEMPERATURE TEST 2a GAUGE BLOWER/MOTOR will be fully welded to the fan adapter plate and the fan adapter plate will be fastened to the curb using a suitably sized fastener provided by others; see page 12 of the EXHAUST FAN MUST OPERATE CONTINUOUSLY STEEL ACCESS DOOR "Installation, Operation and Maintenance Manual" for details. WHILE EXHAUSTING AIR AT 30WF (149'C) 24" SERVICE UNTIL ALL FAN PARTS HAVE REACHED ®�CLEARANCE REQ. Grease duct joints shall be held together by means of formed vee clamps and sealed with 3M Fire Barrier 2000+. Screws used to secure the vee clamps shall be of the hex -head THERMAL EQUILIBRIUM, AND WITHOUT ANY type with flanged stops and tapered "lead in" threads for easy starting. Nuts shall be retained by means of a free-floating cage to allow easy alignment. DETERIORATING EFFECTS TO THE FAN WHICH 3" FLANGE. DRAIN. WOULD CAUSE UNSAFE OPERATION. Single -`,Hall Grease Duct shall be installed in accordance with the manufacturer's "Installation, Operation and Maintenance Manual." ETL listing and State and local codes. Grease ABNORMAL FLARE-UP TEST <22 duct installed outside of the building shall be protected against accidental damage or vandalism. EXHAUST FAN MUST OPERATE CONTINUOUSLY ROOF OPENING WHILE EXHAUSTING BURNING GREASE VAPORS DIMENSIONS. Support vertically installed grease duct from the building structure using rigid structural supports. Anchor supports to the structure by welding or bolting steel expansion anchors or AT 600°F (316'C) FOR A PERIOD OF 15 MINUTES WITHOUT THE FAN BECOMING 22 1/2 concrete inserts. Support horizontally installed grease duct from the building structure using above method. 1/2" Threaded rod and saddles may also be used for the support of DAMAGED "10 ANY EXTENT THAT COULD CAUSE horizontal grease duct. AN UNSAFE CONDITION. 24" EQUIPMENT CURB, /\ Fans shall be supported independently from the grease duct sections. Protect grease duct from twisting or movement caused by fan torque or vibration. OPTIONS PITCHED CURBS ARE AVAILABLE 011 FOR PITCHED ROOFS. ROOF OPENING 2"SMALLER THAN CURB DIMENSION. Certifications GREASE BOX, z YEAR PARTS WARRANTY. 5<, The DW Series has been certified by ITS. This certification mark indicates that the product has been tested to and has met the minimum requirements of a widely recognized SPECIFY PITCH: 12" (consensus) U.S. and Canadian products safety standard, that the manufacturing site has been audited, and that the applicant has agreed to a program of periodic factory EXAMPLE: 7/12 PITCH = 30' SLOPE. follow-up inspections to verify continued performance. Model DW Series is ETL Listed under file number 3114021 and complies with UL 1978 Standard and CAN/ULC-S662. PITCHED CURBS ARE AVAILABLE 0, FOR PITCHED ROOFS. D' SPECIFY PITCH: 12" EXAMPLE: 7/12 PITCH = 30' SLOPE. I SCALE:TO SCALE ELECTRICAL CONTRC PACKAGE -FACTORY err- I i1- In -I I VANE SHALL COVER ELBOW THROAT bxc END VANES SHALL BE LOCATED AT ELBOW WHEEL BACK OF DUCTWORK SHALL NOT BE VISIBLE FROM POINT IN T VOLUME DAMPER SPUTTER I _W_ - IF RAN < 1.0 PROVIDE SPUTTER VANES. THIS DETAIL APPLIES TO 90° RADIUS ELBOWS AND LESS THAN 90° RADIUS ELBOWS AND ANY RECTANGULAR DUCT LESS THAN 90°. O , (a+b)xc , DOUBLE OR ^ U SINGLE BLADE TURNING VANES 15° 12" (a+b)xc MAIN SUPPLY, RETURN OR EXHAUST DUCTWORK 15' VOLUME DAMPER ON RETURN DUCT ONLY. axc SPUTTER DAMPER ON SUPPLY DUCTS ONLY OUTSIDE AIR INTAKE FACTORY FABRICATED, INSULATED ROOF CURB DUCT VIBRATION ISOLATION CONNECTORS — TRANSITION AS REQ'D TO INLET/OUTLET OF AHU PLACE RTU ON ROOF CURB. PROVIDE CONTINUOUS GASKET ON CAP OF ROOF CURB. SECURE RTU AS PER ARCHITECTURAL/STRUCTURAL DRAWINGS. 1" CONDENSATE DRAIN LINE WITH TRAP. (DISCHARGE TO NEAREST ROOF RTU DRAIN) 10� ROOFTOP DETAIL SCALE: NOT TO SCALE It0 a ROOF/JOIST CAPACITY AS PER ARCH/STRUCT FOR ALL SUPPLY/RETURN DUCT SUPPLY RETURN TO DIFFUSER BRANCHES. 4 OR RETURN OR AT SIDE, 45' EXHAUST GRILLE GALVANIZED HOLD OCONNECTION TOP OR BOTTOM OF DOWN STRAP DUCT. Il�I END OF DUCT TO HAVE AIR BALANCING GAS/ MINIMUM 12" J MINIMUM 12" DAMPER (TYP.).cr_ 18" LONG 4X4 TREATED CONDENSATE/ STRAIGHT a STRAIGHT WOOD BLOCK REFIGERANT FROM DUCT w D FROM DUCT PIPING TRANSITION w U) TRANSITION 7 1000, VOLUME DAMPER AT BRANCH TAKEOFFS (TYP.) 1"THICK RIGID INSULATION 18" LONG 2X12 TREATED BRANCH ADHERED TO WOOD BLOCK WOOD SECURED TO 4X4 TURNING WITH GALVANIZED VANES (TYP.) - � DAMPER N HARDWARE DAMPER BRANCH -- _ O SVPP% TRANSITION l IF REQUIRED TYPICAL BRANCH DUCT & FITTINGS DETAILS NOT TO SCALE 7,o,, 45' FITTING. —` MAXIMUM SAG 1/2" PER FOOT (41.7 mm PER m) OF SUPPORT SPACING MAIN DUCT SPLIT MINIMUM OF 1 SUPPORT IF DUCT IS LESS THAN 4' LONG DUCT SHOULD EXTEND STRAIGHT FOR SEVERAL INCHES FROM A CONNECTION BEFORE BENDING. SHARP BENDS ARE S� NOT ALLOWED. (7,g�0 1�,hJ M NOTE: CLOSER MAXIMUM HANGER INTERVALS MAYBE SPECIFIED AS A CONDITION OF U.L. LISTING, PARTICULARLY IN FIRE RATED FLOOR -CEILING ASSEMBLIES. FLEXIBLE DUCT SUPPORTS DETAIL NOT TO SCALE AS PER HVAC DUCT CONSTRUCTION STANDARDS METAL AND FLEXIBLE SMACNA - THIRD EDITION PIPING SUPPORT DETAIL ON ROOF SCALE: NOT TO SCALE 1 MECHANICAL DETAILS M12. SCALE: NOT TO SCALE IVIECHAINICAI SCALE- NOT TO SCALE C&K ARCHITECTS I INTERIORS architecture• interior design • client services AAC001629 4221 WEST BOY SCOUT BLVD., SUITE 150 TAMPA, FL 33607-5743 813.884.2000 280 WEST CENTRAL AVE. WINTER HAVEN, FL 33880-2957 863.577.2054 Q z U 5� M A SF ..NSF 0 • o ` 7 4•' /14/2 21 ' j O STATE OF <v w S�ONAL•�a < w 0 z 0 z z 4 0 v 0 0 c 0 z Z 0 PLUMBING FIXTURE SCHEDULE MARK QTY FIXTURE SOIU VENT COLD HOT ELEC MANUFACTURER DESCRIPTION WASTE WATER WATER CONN. MS-1 1 MOP SINK 2" 2" 1/2" 1/2" - MUSTEE MOLDED MOP BASIN WITH 3" OUTLET. MODEL 63M • PROVIDE FAUCET WITH WALL BRACE, PAIL HOOK AND APPROVED VACUUM BREAKER. • PROVIDE HOSE & HOSE BRACKET, MOP HANGER, BUMPER GUARDS AND STAINLESS STEEL WALL GUARD S-1 2 HAND SINK 1-1/2" 1-1/2" 1/2" 1/2" - REGENCY TABLES AN • 20-GAUGE TYPE 304 STAINLESS STEEL, SINGLE BOWL WITH 1-1/2" IPS DRAIN BASKET, EASY TO SINKS #600HS12SP INSTALL 8" GOOSNECK FAUCET INCLUDED, HOLES PUNCHED FOR 4" CENTERS. S-2 1 3 COMP SINK 1-112" 1-1/2" 1/2" 1/2" - REGENCY TABLES AND ' MADE OF HIGH QUALITY 16-GAUGE, TYPE 304 STAINLESS STEEL, GALVANIZED 1-5/8" STEEL SINKS #60OS318242X LEGS WITH SOCKETS, FAUCET HOLES PRE -PUNCHED ON 8" CENTERS (FAUCET SOLD SEPARATELY). S-3 1 1 COMP PREP SINK 1-1/2" 1-1/2" 1/2" 1/2" - REGENCY TABLES AND MADE OF HIGH QUALITY 16-GAUGE, TYPE 304 STAINLESS STEEL, GALVANIZED 1-5/8" STEEL SINKS #60OS12323G LEGS WITH SOCKETS, FAUCET HOLES PRE -PUNCHED ON 8" CENTERS (FAUCET SOLD SEPARATELY). FD-1 - FLOOR DRAIN 3" - - - - ZURN MODEL Z400H ZURN FLOOR DRAIN "TYPE H" ROUND STRAINER WITH CLAMP DEVICE. • ALL FLOOR DRAINS SHALL BE INSTALLED WITH TRAP PRIMERS. COORDINATE EXACT LOCATIONS AND QUANTITY OF FLOOR DRAINS WITH ARCHITECTURAL DRAWINGS PRIOR TO ROUGH -IN. • PROVIDE TRAP PRIMER CONNECTION TO FLOOR DRAINS IN TOILET ROOMS EQUAL TO J.R. SMITH MODEL 2698, SEE DETAIL ON SHEET 9.1 ALL OTHER FLOOR DRAINS TO BE PROVIDED WITH TRAP PRIMERS EQUAL TO PRECISION PRODUCTS INC., SEE DETAIL ON SHEET P9.1 HD-1 - HUB DRAIN 3" - - - - ZURN MODEL Z1870 • ZURN FLOOR DRAIN "TYPE 304 STAINLESS STEEL" ROUND STRAINER WITH CLAMP DEVICE. TYPE 304 • ALL FLOOR DRAINS/HUB DRAIN SHALL BE INSTALLED WITH TRAP PRIMERS. COORDINATE EXACT LOCATIONS AND QUANTITY OF FLOOR DRAINS WITH ARCHITECTURAL DRAWINGS PRIOR TO ROUGH -IN. • PROVIDE TRAP PRIMER WITH AUTOMATIC TRAP PRIMER VALVE ZURN Z1022-XL. COORDINATE FINAL LOCATION WITH G.C. PLUMBING LEGEND DESCRIPTION SYMBOL NEW SANITARY WASTE BELOW SLAB — — NEW SANITARY WASTE ABOVE SLAB EXISTING SANITARY WASTE ABOVE SLAB TO REMAIN EXISTING SANITARY WASTE TO BE REMOVED X_ X—X—X—X—X _E EXISTING SANITARY WASTE TO BE REMOVED X-X-)(-X-X-X-X GAS, PROPANE LINE GAS EXISTING GAS, PROPANE LINE — — — — — — — NEWVENT ------- EXISTING VENT TO REMAIN — — — — — — — EXISTING VENT TO BE REMOVED X _E -X X iF X- X NEW COLD WATER PIPING — EXISTING COLD WATER PIPING TO REMAIN — EXISTING COLD WATER PIPING TO BE REMOVED x x x X x x NEW HOT WATER PIPING — — EXISTING HOT WATER PIPING TO REMAIN — — EXISTING HOT WATER PIPING TO BE REMOVED Xx—X—X—X X—iE NEW HOT WATER RECIRCULATION PIPING — — EXISTING HOT WATER RECIRCULATION PIPING TO REMAIN — — — EXISTING HOT RECIRCULATION WATER PIPING TO BE REMOVED x X-1X_ X x x STORM WATER DRAIN PIPING ST EXISTING STORM WATER DRAIN PIPING — — — — NEW GREASE/WASTE PIPING GW EXISTING GREASE/WASTE PIPING GW EXISTING GREASE/WASTE PIPING TO BE REMOVED *x_X GWX X TRAP PRIMER PIPING TP TRAP PRIMER TP BACK WATER VALVE SHUT-OFF VALVE SHUT-OFF VALVE WITH VALVE BOX FLOOR DRAIN FLOOR SINK SMOKE DECK POINT OF CONNECTION TO EXISTING SYSTEM PIPE PENETRATION THROUGH FINISHED FLOOR ABBREVIATIONS BALL VALVE BV AIR ADMITTANCE VALVE AAV DOUBLE CHECK BACKFLOW DCBF COLD WATER SYSTEM CW EXISTING EX. FLOOR DRAIN, FLOOR SINK, FLOOR HUB FS, FD, FH GENERAL CONTRACTOR G.C. GRADE/FLOORANALL CLEAN OUT GCO/FCO/WCO HOSE-BIBB HB HOT WATER SYSTEM (110°F) HW HOT WATER RETURN SYSTEM (110°F) HWR INDIRECT DRAIN PIPING ID INVERT ELEVATION BELOW FINISHED FLOOR OR GRADE. I IE PLUMBING CONTRACTOR P.C. TEMPERATURE & PRESSURE RELIEF VALVE T&P UNLESS OTHERWISE NOTED U.O.N. BASIC PLUMBING MATERIAL REQUIREMENTS SOIL WASTE, VENT, ROOF DRAIN PIPING ABOVE GRADE: CAST IRON, NO HUB, WITH STAINLESS STEEL CLAMPS X❑ PVC-DWV, SCHEDULE 40 SOIL WASTE, VENT, ROOF DRAIN PIPING BELOW GRADE: CAST IRON, NO HUB, WITH STAINLESS STEEL CLAMPS XD PVC-DWV, SCHEDULE 40 WATER PIPING ABOVE GRADE: COPPER, TYPE L X CPVC, SCHEDULE 40, RETURN AIR PLENUM RATED WATER PIPING BELOW GRADE: X❑ COPPER, TYPE K, NO JOINTS BELOW GRADE CPVC FUEL GAS PIPING: X❑ SEAMLESS BLACK STEEL PIPE PVC NOTES: X❑ UTILIZE MATERIALS ABOVE UNLESS NOTED OTHERWISE ON PLANS PLUMBING SHEET INDEX P0.1 — PLUMBING GENERAL P4.1 — PLUMBING PROPOSED SANITARY PLAN P5•1 — PLUMBING PROPOSED WATER PLAN P8• i — PLUMBING RISER DIAGRAMS P&I — PLUMBING DETAILS PLUMBING SPECIFICATIONS PART 1 -GENERAL 0.01 GENERAL SCOPE A. THIS PROJECT WILL REQUIRE INSTALLATION OF PLUMBING SYSTEMS AS INDICATED. B. GENERAL CONTRACTOR SHALL FURNISH OWNER WITH COPIES OF AS-BUILTS, WARRANTIES AND OWNER'S MANUALS PRIOR TO REQUESTING FINAL PAYMENT. 1.01 GENERAL DOCUMENTS A. INSTALLATION SHALL BE IN ACCORDANCE WITH THE FLORIDA BUILDING CODE 7TH EDITION 2020 (EFFECTIVE 12/31/2020), WHICH INCLUDES THE FLORIDA BUILDING CODE, PLUMBING AND FUEL GAS CODES. ALL EQUIPMENT SHALL BE UL LISTED. B. THE PLUMBING WORK SHALL INCLUDE FURNISHING ALL LABOR, EQUIPMENT, MATERIALS AND SERVICE NECESSARY FOR THE PROPER COMPLETION OF ALL PLUMBING WORK SHOWN ON THE DRAWINGS AND AS SPECIFIED. ALL MATERIAL SHALL BE NEW. C. THIS ENGINEER IS NOT RESPONSIBLE FOR MATERIALS, METHODS, INSTALLATION, AND CONSTRUCTION WHICH DEVIATE FROM THESE CONSTRUCTION DOCUMENTS AND SPECIFICATIONS. 1.02 SUBMITTALS A. MATERIALS OR PRODUCTS SPECIFIED HEREIN AND/OR INDICATED ON DRAWINGS BY TRADE NAME, MANUFACTURER'S NAME OR CATALOG NUMBERS SHALL BE INTERPRETED AS ESTABLISHING A STANDARD OF QUALITY AND DESIGN. SUBSTITUTIONS MAY BE ALLOWED IF THEY MEET THE QUALITY STANDARDS AND DESIGN INTENT, UNLESS OTHERWISE NOTED. B. PRIOR TO STARTING THE PROJECT, THE PLUMBING CONTRACTOR SHALL STUDY THE COMPLETE SET OF CONSTRUCTION DOCUMENTS AND COORDINATE WITH THE MANUFACTURER(S) AS REQUIRED TO PROVIDE EQUIPMENT SUBMITTALS TO SUBMIT TO PLUMBING ENGINEER OF RECORD FOR REVIEW AND APPROVAL. THE EQUIPMENT SUBMITTALS SHALL INCLUDE DIMENSIONS, WEIGHTS, SPECIFIED ACCESSORIES AND REQUIRED CLEARANCES, AS WELL AS FAN CURVES, SOUND LEVELS, CONSTRUCTION DETAILS, WARRANTY INFORMATION, AND ALL OTHER RELEVANT DATA. C. IF SUBSTITUTIONS TO THE BASIS OF DESIGN ARE SUBMITTED, THE PLUMBING CONTRACTOR SHALL PROVIDE A CLEAR, DETAILED SUMMARY IN THE SUBMITTALS OF THE DIFFERENCES BETWEEN THE SUBMITTED EQUIPMENT AND THE BASIS OF DESIGN. ADDITIONALLY, PLUMBING CONTRACTOR SHALL PROVIDE AN AFFIDAVIT STATING THAT PROPOSED SUBSTITUTION IS AN EQUAL TO THAT WHICH IS SPECIFIED. PLUMBING ENGINEER OF RECORD MAY ACCEPT OR REJECT THE SUBSTITUTIONS. 1.03 SHOP DRAWINGS A. FURNISH SIX (6) COPIES OF SHOP DRAWINGS OF EQUIPMENT, FIXTURES AND SYSTEM LAYOUT TO GENERAL CONTRACTOR PRIOR TO PURCHASING ANY EQUIPMENT AND BEGINNING WORK. 1.04 RECORD DRAWINGS A. AFTER COMPLETION OF ALL WORK, THE PLUMBING CONTRACTOR SHALL PROVIDE THE GENERAL CONTRACTOR WITH AS BUILT RECORD DRAWINGS. PLUMBING CONTRACTOR SHALL KEEP A RECORD OF THE LOCATIONS OF ALL CONCEALED WORK AND UPON COMPLETION OF THE JOB, SHALL SUPPLY AS -BUILT DRAWINGS SHOWING ANY DEVIATION FROM THE ORIGINAL DRAWINGS. THESE DRAWINGS SHALL INDICATE DIMENSION OF BURIED UTILITY LINES FROM BUILDING WALLS. PART 2 - INSTALLATION 2.01 MATERIAL A. SOIL, WASTE, VENT, & ROOF DRAIN PIPING DRAINAGE PIPING: A.A. CAST IRON - SERVICE WEIGHT CAST IRON, NO HUB, WITH STAINLESS STEEL CLAMPS AND SHIELDS WITH NEOPRENE SEALING SLEEVES A.B. PVC - PVC-DWV SCHEDULE 40 PIPE AND BELOW SLAB SHALL BE PVC-DWV SCHEDULE 40 PIPE AND FITTINGS WITH SOLVENT WELD JOINTS AND DRAINAGE PATTERN FITTINGS. A.C. REFER TO BASIC PLUMBING MATERIAL REQUIREMENTS CHART ON THIS SHEET FOR MATERIAL SELECTION. A.D. SAW CUT FLOOR AS NECESSARY FOR INSTALLATION OF NEW SANITARY DRAINAGE PIPING. REPAIR/PATCH FLOOR TO MATCH ADJACENT AREAS. B. DOMESTIC WATER PIPING: B.A. TYPE L COPPER - TUBING WITH LEAD FREE SOLDER JOINTS. B.B. TYPE K COPPER - TUBING WITH LEAD FREE SOLDER JOINTS. B.C. COPPER FITTINGS - PIPE FITTING SHALL BE WROUGHT COPPER, B.D. SCHEDULE 40 CPVC WITH SOLVENT WELD JOINTS ASTM 02846, F441 & F442 INSTALLED AS PER MANUFACTURERS RECOMMENDATIONS. B.E. REFER TO BASIC PLUMBING MATERIAL REQUIREMENTS CHART ON THIS SHEET FOR MATERIAL SELECTION. C. PIPE INSULATION: HOT WATER SUPPLY AND RETURN PIPING SHALL BE INSULATED WITH 1" THICK R-6 MINIMUM FIBERGLASS OR EQUAL, IN COMPLIANCE WITH APPLICABLE ENERGY CODES, STORM WATER PIPING INCLUDING ROOF DRAIN SUMPS, ALL HORIZONTAL RAINWATER LEADERS & ANY PIPING ABOVE SLAB RECEIVING COLD WATER DISCHARGE FROM A/C UNITS, ICE MACHINES ETC. SHALL BE INSULATED WITH 1" THICK R-6 MINIMUM FIBERGLASS (OR EQUAL) INSULATION WITH VAPOR JACKET. 2.02 VALVES A. EQUAL TO NIBCO, CRANE, OR WALWORTH. ALL BRONZE 150 LB. BALL VALVES WITH RISING STEMS. 2.03 SPECIALTIES H. PROVIDE UL LISTED FIRE STOPPING PIPE PENETRATION ASSEMBLIES AT ALL PIPING THROUGH RATED WALLS AND ASSEMBLIES. I. TRAP PRIMERS: RESEAL ALL FLOOR DRAIN TRAPS WITH 2' WATER LINE CONNECTED TO A TRAP PRIMER FITTING IN THE COLD WATER SUPPLY LINE SERVING A FREQUENTLY USED PLUMBING FIXTURE. J. ADA WRAP: HANDICAPPED LAVATORIES SHALL HAVE ADA APPROVED UNDER COUNTER WRAP FOR WASTE AND WATER PIPING. PART 3 - EXECUTION 3.01 INSTALLATION A. INSTALL PIPE ABOVE GROUND PLUMB AND SQUARE WITH BUILDING LINES, ADEQUATELY SUPPORTED WITHOUT SAGS OR HIGH POINTS, CONCEAL PIPING IN OCCUPIED AREAS AND MAINTAIN HEAD ROOM AND ACCESS SPACE IN UNFINISHED AREAS. SLEEVE PIPING THROUGH ALL WALLS, SLABS, OR PARTITIONS WITH ESCUTCHEONS AT ALL FINISHED SURFACE. PROVIDE UNIONS AT ALL FINAL CONNECTIONS AND STOPS ON ALL SUPPLIES. ALL PIPE OPENINGS SHALL BE PLUGGED DURING INSTALLATION. B. SANITARY DRAINAGE PIPING 3" & LARGER SHALL BE INSTALLED WITH A MINIMUM 1/8" PER FOOT SLOPE UNLESS NOTED OTHERWISE. ALL DRAINAGE PIPING 2-1/2" AND SMALLER SHALL BE INSTALLED WITH A MINIMUM OF 1/4" PITCH PER FOOT. C. ALL FIXTURES AND TRIM FOR HANDICAPPED SHALL BE INSTALLED IN COMPLIANCE WITH ADA CODE, D. INSTALL ALL PIPING TO ALLOW FOR EXPANSION. E. SEE RISER DIAGRAMS FOR ALL DRAINAGE &VENT PIPE SIZING FOR THE PLUMBING SYSTEMS. REFER TO PLUMBING FLOOR PLAN (WATER SYSTEM) & SCHEDULES FOR ALL WATER PIPING SYSTEM SIZING. F. ALL WORK ASSOCIATED WITH HANDICAPPED TOILETS SHALL COMPLY WITH ADA REQUIREMENTS AND FLORIDA BUILDING CODE - CHAPTER 11 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION. G. FINAL CONNECTIONS TO DRAINAGE AND WATER SERVICE LINES TO EXISTING OR NEW AS SHOWN ON THESE DOCUMENTS SHALL BE BY THE PLUMBING CONTRACTOR. 3.02 DISINFECTING OF POTABLE WATER SYSTEM A. THE SYSTEM SHALL BE FILLED WITH A SOLUTION CONTAINING 50 PARTS PER MILLION OF AVAILABLE CHLORINE AND ALL ALLOWED TO STAND 24 HOURS BEFORE FLUSHING AND RETURNING TO SERVICE. DISINFECTION PROCEDURE AND RESULT SHALL BE SUBJECT TO THE APPROVAL OF THE LOCAL PLUMBING INSPECTOR. 3.03 TEST A. ALL PLUMBING SYSTEMS SHALL BE TESTED IN ACCORDANCE WITH THE FLORIDA BUILDING CODE PLUMBING. ALL TESTS SHALL BE APPROVED BY THE LOCAL PLUMBING INSPECTOR AND SHALL BE OBSERVED BY A REPRESENTATIVE OF THE OWNER. 3.04 SYSTEM IDENTIFICATION A. THE PLUMBING CONTRACTOR SHALL PROVIDE IDENTIFICATION TAGS FOR ALL NEW PIPING AND VALVES IN THE BUILDING AS PER OWNER ACCEPTED STANDARDS, THE PIPE MARKS SHALL INCLUDE PIPING SYSTEM IDENTIFICATION AND DIRECTIONS OF FLOW. EVERY 10 FEET AND CHANGES OF DIRECTION. 3.05 SPECIFICATIONS AND DRAWINGS A. PLUMBING CONTRACTOR SHALL FURNISH AND INSTALL COMPLETE SANITARY, STORM, AND DOMESTIC WATER PIPING SYSTEMS: INCLUDING ALL ASSOCIATED DEVICES, EQUIPMENT, CONTROLS, AND CONNECTIONS TO NEW SERVICES, SUPPORTS, AND HARDWARE REQUIRED FOR THE SATISFACTORY OPERATIONS OF THE SYSTEMS, WHETHER SPECIFICALLY SHOWN OR NOT ON THE DRAWINGS. B. THE PLANS SHOW THE LOCATION OF ALL FIXTURES AND EQUIPMENT AND ARE INTENDED TO DEPICT THE GENERAL INTENT OF THE WORK IN SCOPE, LAYOUT, AND QUALITY OF WORKMANSHIP. THEY ARE NOT INTENDED TO SHOW IN MINUTE DETAIL EVERY AND ALL ACCESSORIES INTENDED FOR THE PURPOSE OF EXECUTION OF THE WORK, BUT IT SHALL BE UNDERSTOOD THAT SUCH DETAILS SHALL BE PART OF THIS WORK. C. THE DRAWINGS AND SPECIFICATIONS ARE MEANT TO BE SUPPLEMENTARY, HOWEVER, WHERE DRAWINGS AND SPECIFICATIONS CONFLICT, IT SHALL BE THE RESPONSIBILITY OF THIS CONTRACTOR TO BRING SUCH CONFLICT TO THE ATTENTION OF PLUMBING ENGINEER OF RECORD FOR CLARIFICATION. D. REFER TO ARCHITECTURAL DRAWINGS AND VERIFY FIELD CONDITIONS FOR EXACT LOCATION OF ALL PLUMBING FIXTURES. E. ALL DOCUMENTS, TEST REPORTS, & AS -BUILT DRAWINGS SHALL BE ATTACHED TO THE CLOSING DOCUMENTS OF THE PROJECT. 3.06 WARRANTY A. THE PLUMBING CONTRACTOR SHALL WARRANT ITS WORK TO BE FREE FROM DEFECTS IN MATERIALS AND WORKMANSHIP FOR A PERIOD OF ONE YEAR FROM FINAL ACCEPTANCE OF ALL WORK. B. THE PLUMBING CONTRACTOR SHALL PROVIDE FIVE (5) BOUND COPIES OF ALL PLUMBING CONTRACTOR WARRANTIES, MANUFACTURER'S WARRANTIES, PARTS LISTS, AND INSTALLATION AND MAINTENANCE MANUALS FOR ALL PLUMBING EQUIPMENT, AS WELL AS INSTRUCTIONS FOR OPERATING AND MAINTAINING ALL PLUMBING EQUIPMENT TO THE OWNER UPON FINAL COMPLETION, 3.07 COORDINATION A. PIPE PROTECTIVE COATING: FOR STEEL OR COPPER PIPE, PERMACEL OR SCOTCHWRAP VINYL TAPE APPLIED OVER PIPE TO A TOTAL MINIMUM THICKNESS OF 20 MLS. APPLY TO ALL WATER PIPE IN CONTACT WITH MASONRY OR CONCRETE. B. PIPE HANGERS: HANGERS FOR BARE COPPER PIPE THROUGH 4 INCH (4") DIAMETER OR SMALLER SHALL BE ADJUSTABLE RING TYPE, PLASTIC COATED EQUAL TO MICHIGAN 102a, FOR STEEL PIPE MICHIGAN 100. C. DRAINS AND CLEANOUTS: SEE SCHEDULE ON DRAWINGS. D. DIELECTRIC UNIONS: PROVIDE EBCO OR CAPITOL DIELECTRIC UNIONS AT ALL POINTS OF CONNECTION BETWEEN DISSIMILAR PIPE METALS. E. FLASHING AND VENT STACKS: ALL VENTS EXTENDING THROUGH THE ROOF SHALL BE PROVIDED WITH FOUR POUND SHEET LEAD FLASHING EXTENDING UPWARD AROUND THE PIPE AND TURNED DOWN INSIDE THE PIPE OR AS OTHERWISE SHOWN ON THE DRAWINGS. THE ROOF FLASHING SHALL BE INSTALLED BY LICENSED ROOFING CONTRACTOR. F. ESCUTCHEONS AND SLEEVES. WHERE PIPES PIERCE EXPOSED PARTITIONS, FLOORS, WALL, OR CEILINGS, PROVIDE CHROME PLATED ESCUTCHEONS TO THE COVER THE RAW EDGE. G. SLEEVES SHALL BE PROVIDED A ALL PIPE PENETRATIONS OF MASONRY AND CONCRETE WALLS AND FLOORS. A. COORDINATE WORK WITH OTHER TRADES AND EXISTING CONDITIONS PRIOR TO BEGINNING WORK. PLUMBING CONTRACTOR SHALL PROVIDE ROUTING AND OFFSETS NECESSARY TO AVOID CONFLICT WITH STRUCTURE, FINISHES, AND WORK OF OTHER TRADES. B. VERIFY LOCATIONS, SIZES, AND INVERT ELEVATIONS OF SANITARY DRAIN, AND DOMESTIC WATER PIPING CONNECTIONS WITH FIELD CONDITIONS AND CIVIL ENGINEERING DRAWINGS (AS APPLICABLE) PRIOR TO PROCEEDING WITH THE WORK. SHOULD ANY DISCREPANCIES BE DISCOVERED, PLUMBING CONTRACTOR SHALL SUBMIT A REQUEST FOR INFORMATION TO PLUMBING ENGINEER OF RECORD. C. COORDINATE WITH ARCHITECTURAL DRAWINGS FOR WALL AND PARTITION CONSTRUCTION AND THICKNESS WHERE PLUMBING PIPING, FIXTURES CARRIERS OR EQUIPMENT IS INDICATED. BEFORE STARTING CONSTRUCTION, IDENTIFY ANY CONFLICT PRIOR TO STARTING CONSTRUCTION. D. COORDINATE EXACT LOCATION, ELEVATIONS, AND SIZES OF ALL SLEEVES IN NEW STRUCTURE WITH STRUCTURAL AND ARCHITECTURAL DRAWINGS AND FIELD CONDITIONS. GS JOB #: S831 .21 .00 GLOBAL 5,,�Cn�ZINC. MEPF ENGINEERING INFO@GLOBAL-SANCHEZ.COM CA#: 6237 B 1 6 MANATEE AVE. E, SUITE 18 BRADENTON, FL 3420B PHONE: 941-75B-2SS1 3825 HENDERSON BLVD., SUITE 103 TAMPA, FL 33629 PHONE: B 1 3-28 1 -❑❑❑ 1 C&K ARCHITECTS I INTERIORS architecture• interior design -client services AAC0.01629 4221 WEST BOY SCOUT BLVD., SUITE 150 TAMPA, FL 33607-5743 813.884.2000 280 WEST CENTRAL AVE. WINTER HAVEN, FL 33880-2957 863.577.2054 c A SF� N 1 4' u 5/1 /2021: W STATE OF I '• FtOR��Pr°G� SS/ONAL1�� - z c _ t 2 z 0 - ' s i mQ 0 O z J LL � J x 0- w N v r i O I..L Z W ( Z Lu NO m I J J Q 0 M LO 01 ISSUED FOR: PERMIT PROJECT NUMBER 21020 DATE 5.5.21 DRAWING NUMBER PO I I GREASE INTERCEPTOR CALCULATIONS Reference No. 27245 Step 1: Flow rate to grease interceptor Fixture flow rate., (cu in / 231) = gat x 0. 75 / 2 min = 2 min flow rate AUTOMATIC TRAP PRIMER VAL Project Name'. Bubbakoos Buritos #23 3­oomp .3 ComparTme Fit Sink 20' x 20'x 14'(3) 1 16,800 27.27 GPM ;39 Mop Sink Mop Basin 24' x 24' x I O1 5,760 91.35 GPM #6 Prep Sink One Bowl 20' x 20'x 14� 1 5$600 9.09 GPM Total 45.71 GPM Step 2: Grease Production Servings per day x Grease production value x Days between pump -outs- = Grease output Number of meals served per day: 250 Grease production value: 0.035 lbs per serving (Mexican: High / No flatware) Days between pump -outs: 90 days 250 x 0.035 x 90 = 787.5 lbs- of FOG P.C. VERIFY CONNECT EXISTING 3" SANITARY P.C. REMOVE ALL EXISTING AND REPLACE WITH 'y EXISTING SANITARY PIPING (VIF.) z SCALE: 1/4" = V-0" EOUPIMENT LEGEND (?_1 ICE CUBER 0 WALK-IN COOLER 6' X 10' Fs POINT -OF -USE WATER NEATER PROVIDED AND INSTALLED BY G.C. PREP SINK REA04-IN FREEZER REFRIGERATED EQUIP. STAND F231 3-COMP.SINK F2A GAS GRIDDLE 48' F25 GAS GRIDDLE 24' a GAS FRYER MAGAS NOSE KIT —2b "D SINK GREASE TRAP PROVIDED AND INSTALLED BY G.C. MOP SINK PROVIDED AND INSTALLED BY G.C. PEP51 COOLER BY TENANT VENDOR. ®PEPSI DISPENSER BY TENANT VENDOR. � REACH IN FREEZER Ak YL u Oc-, CC KEY PLAN SCALE: NOT TO SCALE E C&K ARCHITECTS INTERIORS architecture - interior design• client services AAC001629 4221 WEST BOY SCOUT BLVD., SUITE 150 TAMPA, FL 33607-5743 813.884.2000 280 WEST CENTRAL AVE. WINTER HAVEN, FL 33880-2957 863.577.2054 APS M. 4- /1 /2021110� . U 0. STATE OF X\ % OR\DP-` ss�ON L ma C; z LL Cd a. Lh FLU D < U) z 0 LL1 a C/) C/) ax! 0 0 11.1 CL �e 0 < 13� C93 CL cm (D z 6 _J rrJnn _J L CL 0 ISSUED FOR: PERMIT PROJECT NUMBER 21020 DATE 5.5.21 DRAWING NUMBER P4n I ZURN BEVERAGE BACKFLOW Z740 DRAIN DISCHARGE TO NEAREST FLOOR SINK EXISTING RESTROOMS TO REMAIN. FIELD VERIFY AND PROVIDE ASSE1070 MIXING UNDER EVERY LAVATORY T VALVE, COORDINATE WITH AL 754 MBH AT 2 PSI 0 2' 4' 8' SCALE: 114" = 1'-0" COMMERCIAL CONDENSING, - OUTDOOR, TANKLESS WATER HEATER BY RINNAI WALL MOUNTED. (MODEL CU199EN, 199 MBH INPUT, 120 VOLTS SINGLE PHASE) PROVIDED BY FOOD SERVICE EQUPIMENT LEGEND ICE CUBER WALK-IN COOLER 8' X 10' POINT -OF -USE WATER NEATER PROVIDED AND INSTALLED BY G.C. PREP SINK REACH -IN FREEZER REFRIGERATED EQUIP. STAND 3-COMP.SINK GAS GRIDDLE 48' GAS GRIDDLE 24' GAS FRYER GAS N05E KIT FWD SINK GREASE TRAP PROVIDED AND INSTALLED BY G.C. MOP SINK PROVIDED AND INSTALLED BY G.C. PEPSI COOLER BY TENANT VENDOR. PEPSI DISPENSER BY TENANT VENDOR. REACH IN FREEZER INSTALL GAS MANIFOLD NO MORE 1 FEET FROM WALL 1 114" GAS LINE DOWN IN WALL TO GAS GRIDDLE 48" - 84 MBH GAS GRIDDLE 24%56 MBH GAS FRYER-105MBH EACH, (3) TOTAL 315 MBH HOT PLATE 100 MBH :V, 9 UTi�/:7 s4°GAS TO WATER HEATER KEY PLAN SCALE: NOT TO SCALE e- r� C&K ARCHITECTS INTERIORS architecture -interior design • client services AAC001629 4221 WEST BOY SCOUT BLVD., SUITE 150 TAMPA, FL 33607-5743 813.884.2000 280 WEST CENTRAL AVE. WINTER HAVEN, FL 33880-2957 863.577.2054 7 54'' 0 °.• STATE OF k/ v sS/0NA1_ Z 0 N S T w 0 0 Z I A J LL J V Z x x a w �i V W� O r W W z O O o- a W 0 "SOOO 0 a m V Z m m o J o0 J 0 ^ CL M 01 LO ISSUED FOR: PERMIT PROJECT NUMBER 21020 DATE 5.5.21 DRAWING NUMBER P5m i / Pp 00 \' \ \ \/ v Gw G C GPSa GPS�p�P� `7 G'9S a� ow i �o f ys P00 ��� 'COMP G) D �yP �O . z GPS GS JOB *: 5831,21. GLOBAL 34%NCr'1r'.Z1K4C MEPF ENGINEERING INFO@GLOBAL-SANCHEZ.COM CA#: 6237 61 6 MANATEE AvE. E, SUITE 1 8 BRADENTON, FL 34208 PHONE: 941-758-255 1 3825 HENDERSON BLvD., SUITE 103 TAMPA, FL 33629 PHONE: 8 1 3-28 1-000 1 C&K ARCHITECTS I INTERIORS architecture • interior design. client services AAC001629 4221 WEST BOY SCOUT BLVD., SUITE 150 TAMPA, FL 33607-5743 813.884.2000 280 WEST CENTRAL AVE. WINTER HAVEN, FL 33880-2957 863.577.2054 g z U 4-� 0 5 Q w 5/14/2021;: W ,c� •. STATE: OF to NAL•�� w Z w s _ O a m 0 0 0 Z 0 0 z > Q 0 m 0 o z w J L Jz 0 2 a � ) N Z N w 0 0 w r n V ~ aCLOO c a W a U z 0 U) } 0 = Lu O o Q N U Z MQ W w M W O J o > J � CD z J J '< V - z z M LO 01 � U to C Z O ISSUED FOR: U PERMITCD PROJECT NUMBER 0 — 21020 z z DATE 5.5.21 Z DRAWING NUMBERP8ml Z F z 5 a c z U MAKE UP AIR SHUTDOWN PER NFPA 96: 8.3 LIQUID FIRE SUPPRESSANT TO HOOD FIRE NOZZLES FROM FIRE DETECTING SENSORS ELECTRIC POWER LIQUID FIRE SHUTDOWN PER SUPPRESSANT TO HOOD FIRE NOZZLES NFPA 96. 10.4 FIRE TO FIRE SUPPRESSION ALARM UNIT BY TO GAS MAIN `s— SYSTEM OTHERS TO ELECTRICAL GAS _ SHUTOFF VALVE PLUMBING CONTRACTOR SHALL INSTALL ELECTRICAL GAS SHUTOFF VALVE FURNISHED BY CONTRACTOR. FIRE CONTRACTOR RESPONSIBLE FOR WIRING VALVE BACK TO FIRE ALARM SYSTEM TYP FIRE SUPRESSION RISER DIAGRAM NOT TO SCALE GRATE TYPE AND OPENINGS TO BE SELECTED TO MEET EQUIPMENT CONNECTION REC' „—R A - 1— FINISHED FLOOR SLOPED TOWARDS FLOOR SINK DRAIN LINE Y • • •r • • • SLAB DY - SMOOTH INTERIOR WALL SURFACE OUTLET. SEE FLOOR PLANS PIPE SIZES. 'OM DOME STRAINER GAS TANKLESS WATER HEATER DETAIL J d 2" GAS = W o JE /4'HWR THERMOMETER W/ GAUGE COCK EXPANSION TANKMIXING VALVE SETCIRC. PUMP (%4'HP) AT 110' MAXIMUMCHECK VAL PROVIDE FLUE VENT AS Q f REQUIRED BY MFR. c� U AND BY LOCAL CODES. RUN w w GAS VENT TO EXTERIOR AND Y w TERMINATED AT EXTERIOR z = THE EDGE OF CANOPY. w THIMBLE ASSEMBLY AND CAP Ua i TYPICAL SHUT-OFF VALVE AQUASTAT LeLe CHECK VALVE - - TYPICAL SHUT-OFF VALVE I ILa u AS REGULATOR SET PER MANUFACTURE REQ'D [PING TO FLOOR DRAIN " DIRT LEG FLOOR SINK TO BE FLUSH WITH FINISHED FLOOR UNLESS OTHERWISE REQUIRED BY LOCAL CODE WATER AND FIRE PROOFING AROUND FLOOR SINK HUB OUTLET FIRE PROOFING: WHEN REQUIRED BY FLOOR CEILING ASSEMBLY, PROVIDE UL LISTED FIRE PROOFING ASSEMBLY THAT MEETS FLOOR / CEILING CONSTRUCTION. SEE ARCHITECTURAL DRAWINGS FOR DETAIL. FLOOR SINKS TO BE EQUAL TO MIFAB MODEL FS1760-TB, (12" 0 UNLESS OTHERWISE NOTED). FLOOR SINK DETAIL (FS) NOT TO SCALE 0 KEYED NOTES: 1. APPROVED UNION 2. APPROVED GAS SHUT OFF VALVE 3. FROM GAS SUPPLY 4. MINIMUM 6" LONG DIRT LEG WITH THREADED CAP 5. TO UNIT INLET CONNECTION GAS CONNECTION TO EQUIPMENT NOT TO SCALE PLUMBING DETAILS SCALE: NOT TO SCALE il i " i C&K ARCHITECTS I INTERIORS architecture• interior design• client services AAC001629 4221 WEST BOY SCOUT BLVD., SUITE 150 TAMPA, FL 33607-5743 813.884.2000 280 WEST CENTRAL AVE. WINTER HAVEN, FL 33880-2957 863.577.2054 cq M S�• m PAS'\ N 9 0 4 4 _° '; 5/14/2021 o: ., STATE W OF �v N w SS/ON L•E� w a Z s z z 3 a U 0 c C Z c C z o x C z a N S Q Z ma 0 - s Z 0 Z J LL J� J a N z _ I U o O 0 W J � c W = o m CL o O ZCL = W O N \100 a o o o w J m m a z a o J o In J - J 'Q V z_ � M L 01 U U u') C z O ISSUED FOR: PERMIT z Q PROJECT NUMBER 21020 0 DATE o 5.5.21 z DRAWING NUMBER low G Z a P901 Z 0 Z 0 LIGHT FIXTURE SCHEDULE LAMPS TYPE MANUFACTURER CATALOG NUMBER VOLTS MOUNTING COMMENTS I QTY WATTS/TYPE CREE LIGHTING CR22-32L; 35WLED; 50K 2X2 LED LIGHT FIXTURE, COORDINATE FINAL LIGHTING SELECTION WITH APPROVED EQUAL FROM TAMPA BAY LIGHTING 35W GRID OWNER. Al _ LED 120V CEILING APPROVED EQUAL FROM SESCO LIGHTING APPROVED EQUAL FROM WESTERN FLORIDA LIGHTING CREE LIGHTING 2X2 LED LIGHT FIXTURE, COORDINATE BACK UP FINAL LIGHTING SELECTION WITH APPROVED EQUAL FROM TAMPA BAY LIGHTING 35W GRID OWNER. WITH EMERGENCY BATTERY Al/EM _ LED 120V CEILING BACK UP. APPROVED EQUAL FROM SESCO LIGHTING APPROVED EQUAL FROM WESTERN FLORIDA LIGHTING LITHONIA 72TL4 2'X4' LED 2X4 LED LIGHT FIXTURE, COORDINATE FINAL LIGHTING SELECTION WITH APPROVED EQUAL FROM TAMPA BAY LIGHTING 44W GRID OWNER. B - LED 120V CEILING APPROVED EQUAL FROM SESCO LIGHTING APPROVED EQUAL FROM WESTERN FLORIDA LIGHTING LITHONIA 7BACKUP 2X4 LED LIGHT FIXTURE, COORDINATE FINAL LIGHTING SELECTION WITH APPROVED EQUAL FROM TAMPA BAY LIGHTING 44W GRID OWNER. WITH EMERGENCY BATTERY B/EM _ LED 120V CEILING BACK UP. APPROVED EQUAL FROM SESCO LIGHTING APPROVED EQUAL FROM WESTERN FLORIDA LIGHTING LITHONIA LITHONIA WF6-LED-50K-90CRI-MW 7W 6" LED RECESSED CAN LIGHT, COORDINATE FINAL LIGHTING APPROVED EQUAL FROM TAMPA BAY LIGHTING 14W SELECTION WITH OWNER. C LED 120V RECESSED APPROVED EQUAL FROM SESCO LIGHTING APPROVED EQUAL FROM WESTERN FLORIDA LIGHTING MACRO AIR CEILING FAN, COORDINATE FINAL COLOR BLACK SELECTION WITH OWNER. APPROVED EQUAL FROM TAMPA BAY LIGHTING 350W CEILING F - LED 120V FAN APPROVED EQUAL FROM SESCO LIGHTING APPROVED EQUAL FROM WESTERN FLORIDA LIGHTING LITHONIA ELM2L 120V OR 277V AC. EMERGENCY UNIT PROVIDED WITH TEST SWITCH, STATUS APPROVED EQUAL FROM TAMPA BAY LIGHTING 120/ WALL INDICATOR AND RECHARGEABLE EL 2 1.8W/LED 277V OR BATTERY. MAINTENANCE -FREE APPROVED EQUAL FROM SESCO LIGHTING CEILING NICKEL -CADMIUM BATTERY PROVIDES APPROVED EQUAL FROM WESTERN FLORIDA LIGHTING 90 MINUTES OF EMERGENCY POWER. LITHONIA EXR LED EL M6 EXIT SIGN WITH RED LETTERS. WHITE CEILING THERMOPLASTIC HOUSING. APPROVED EQUAL FROM TAMPA BAY LIGHTING 120/ OR MAINTENANCE -FREE NI -CAD BATTERY EX - 2W/LED 277V WALL PROVIDES 90 MINUTES OF APPROVED EQUAL FROM SESCO LIGHTING MOUNT EMERGENCY POWER. APPROVED EQUAL FROM WESTERN FLORIDA LIGHTING LITHONIA ECR LED HO M6 RED LETTERS, DUAL -VOLTAGE INPUT 120V OR 277V AC; 9.6V OUTPUT. APPROVED EQUAL FROM TAMPA BAY LIGHTING 120/ NICKEL -CADMIUM BATTERY PROVIDES EXL 2 3.8WlLED 277V CEILING 90 MINUTES OF EMERGENCY POWER. APPROVED EQUAL FROM SESCO LIGHTING HIGH OUTPUT (HO) OPTION POWERS UP APPROVED EQUAL FROM WESTERN FLORIDA LIGHTING TO 2 LED REMOTE LAMPS. NOTES: 1. SUBSTITUTIONS WILL NOT BE PERMITTED WITHOUT APPROVAL FROM THE ENGINEER, FOURTEEN DAYS PRIOR TO BID DATE. 2. VERIFY LIGHTING FIXTURE COLOR/FINISH WITH ARCHITECT PRIOR TO ORDERING. 3. ADJUST MOUNTING HEIGHTS/LOCATIONS TO SUIT FIELD CONDITIONS. 4. (2) LAMPS TO BE WIRED IN PARALLEL FOR EMERGENCY BALLAST. DISCONNECT SCHEDULE D/C # SIZE POLES PHASE NEMA FUSE VOLT. SERVES COMMENTS D-1 60A 3 3 3R NON-F 208 RTU-1 MOUNT ON UNIT D-2 60A 3 3 3R NON-F 208 RTU-2 MOUNT ON UNIT D-3 30A 3 3 3R NON-F 208 KSF-1 MOUNT ON UNIT D-4 30A 3 3 3R NON-F 208 KEF-1 MOUNT ON UNIT D-5 30A 3 3 3R NON-F 208 KEF-2 MOUNT ON UNIT D-6 400A 3 3 3R 400A 208 MAIN MOUNT ON WALL NOTES 1. VERIFY FUSE SIZES FOR ACTUAL EQUIPMENT SUBMITTED. 2. FUSES SHALL BE DUAL ELEMENT, TIME DELAY, 100,000 AIC MININUM. 3. FINAL CONNECTIONS TO MECHANICAL EQUIPMENT FROM DISCONNECT SHALL BE FLEX. FLEX SHALL BE WATERTIGHT AT EXTERIOR OR WET LOCATIONS. ADDITIONAL POLE TO DISCONNECT NEUTRAL SHALL BE PROVIDED WHERE REQUIRED. L4. 5. ALL DISCONNECTS SHALL HAVE LOCKED OFF PROVISION. SPECIAL INFORMATIONAL NOTE: THIS DRAWING PREPARED FOR TENANT IMPROVEMENTS TO AN EXISTING BUILDING OR BUILDING CONSTRUCTED BY OTHERS IT IS UNDERSTOOD THAT ANY WARRANTY INFORMATION CONCERNING EQUIPMENT INSTALLED MUST BE FORWARDED TO THE OWNER AND THAT ANY AND ALL CONTRACTORS SHALL GUARANTEE THEIR WORK FOR A PERIOD OF ONE YEAR FROM THE DATE OF OWNERS ACCEPTANCE. ENGINEER IS NOT RESPONSIBLE FOR MATERIALS, METHODS, INSTALLATION, AND CONSTRUCTION WHICH DEVIATE FROM CONSTRUCTION DOCUMENTS AND SPECIFICATIONS. ELECTRICAL SHEET INDEX EO.1 - ELECTRICAL GENERAL EO.2 — ELECTRICAL SPECIFICATIONS E4.1 — ELECTRICAL PROPOSED LIGHTING PLAN E5.1 — ELECTRICAL PROPOSED POWER PLAN E5.2 — ELECTRICAL ROOF POWER PLAN E7.1 — ELECTRICAL SCHEDULES & RISER DIAGRAM E8.1 - NOT USED EO.1 - ELECTRICAL DETAILS SWITCHES 0 $M 0S $a REFER TO SHEET E9.1 FOR SWITCH DETAILS. ELECTRICAL SYMBOL LEGEND WIRING DEVICES NOTE: THE FOLLOWING ABBREVIATIONS APPLY TO WIRING DEVICES WHERE INDICATED: 'WP' INDICATES WEATHERPROOF WHILE -IN -USE ENCLOSURE. ENCLOSURE SHALL HAVE LOCKABLE COVER. DEVICES SHALL BE LISTED AS WEATHER RESISTANT. (WR) 'EWC' INDICATES DEVICE MOUNTED BEHIND ELECTRIC WATER COOLER ENCLOSURE. COORDINATE DEVICE LOCATION WITH PLUMBING CONTRACTOR AND APPROVED "2P" INDICATES A 2-POLE SWITCH SHOP DRAWINGS PRIOR TO ROUGH -IN. CIRCUIT BREAKER SHALL BE GFCI TYPE. 'H' INDICATES HORIZONTALLY MOUNTED WIRING DEVICE. "3" INDICATES THREE-WAY SWITCH 'R' INDICATES DEVICE SHALL BE A RED COLOR. DEVICE IS CONNECTED TO A CIRCUIT FED FROM THE GENERATOR (IF APPLICABLE). "4" INDICATES FOUR-WAY SWITCH 'FD' INDICATES RECEPTACLE MOUNTED IN FLOOR DUCT. INSTALL ACCESSORIES FOR MOUNTING OF RECEPTACLE IN FLOOR DUCT SYSTEM. "30A" INDICATES THE AMPERAGE OF THE SWITCH FOR NON-STANDARD 'IG' ISOLATED GROUND SWITCHES 'USB' INDICATES RECEPTACLE WITH USB OUTLETS. (I) 20 AMP SIMPLEX RECEPTACLE, RECESS MOUNT 18" AFF TO CENTER OF BACKBOX OR REFER TO SHEET E9.1 FOR SWITCH DETAILS. 'I' AT HEIGHT INDICATED. "K" INDICATES KEY SWITCH. PROVIDE OWNER WITH (2) KEYS PER SWITCH. 20 AMP DUPLEX RECEPTACLE, RECESS MOUNT 18" AFF TO CENTER OF BACKBOX. MATCH ANY EXISTING KEYED SWITCHES IF RENOVATION. VERIFY KEY TYPE 20 AMP DUPLEX RECEPTACLE, RECESS MOUNT AT HEIGHT INDICATED OR ABOVE (MANUFACTURER) WITH OWNER COUNTER, CASEWORK, ETC. COORDINATE MOUNTING HEIGHT WITH ARCHITECTURAL "M" INDICATES THE SWITCH SHALL BE MOTOR DUTY RATED ELEVATIONS AND EXISTING CONDITIONS PRIOR TO ROUGH -IN. AFCI 20 AMP DUPLEX RECEPTACLE WITH ARC FAULT CIRCUIT INTERRUPTER (AFCI) "OS" INDICATES OCCUPANCY SENSOR SWITCH (SENSOR SWITCH WSX PDT) If PROTECTION, RECESS MOUNT AT HEIGHT INDICATED OR ABOVE COUNTER, CASEWORK, ETC. COORDINATE MOUNTING HEIGHT WITH ARCHITECTURAL "TS" INDICATES INTERVAL TIMER SWITCH PROGRAMMED FOR 30 MINUTES ELEVATIONS AND EXISTING CONDITIONS PRIOR TO ROUGH -IN. MAXIMUM ALLOWED TIME (SENSOR SWITCH PTS60) AFCI 20 AMP DUPLEX RECEPTACLE WITH ARC FAULT CIRCUIT INTERRUPTER (AFCI) "P" INDICATES SWITCH WITH PILOT LIGHT. (ttj PROTECTION, RECESS MOUNT 18" AFF TO CENTER OF BACKBOX. 1 OF 2 RECEPTACLES IS SWITCHED, REMOVE JUMPER BETWEEN OUTLETS. "R" INDICATES DEVICE SHALL BE A RED COLOR. DEVICE IS CONNECTED TO A AFCI 1p 20 AMP DUPLEX RECEPTACLE WITH ARC FAULT CIRCUIT INTERRUPTER (AFCI) CIRCUIT FED FROM A GENERATOR (IF APPLICABLE). PROTECTION, RECESS MOUNT 18" AFF TO CENTER OF BACKBOX. LOWER CASE LETTER (i.e. "a") INDICATES THE FIXTURE(S) CONTROLLED BY !1fh: 20 AMP DOUBLE DUPLEX (QUAD) RECEPTACLE WITH COMMON COVER PLATE, RECESS THE SWITCH. MOUNT 18" AFF TO CENTER OF BACKBOX. 20 AMP DOUBLE DUPLEX (QUAD) RECEPTACLE WITH COMMON COVER PLATE, RECESS MOUNT ABOVE COUNTER, CASEWORK, ETC OR AT HEIGHT INDICATED. COORDINATE LIGHTING FIXTURES (REFER TO THE "LIGHTING FIXTURE SCHEDULE") MOUNTING HEIGHT WITH ARCHITECTURAL ELEVATIONS AND CONDITIONS PRIOR TO ROUGH -IN. 2' x 4' FLUORESCENT LIGHT FIXTURE (SEE LIGHT FIXTURE SCHEDULE) b NOTE: THE FOLLOWING ABBREVIATIONS APPLY TO LIGHTING FIXTURES WHERE 20 AMP DUPLEX RECEPTACLE, RECESS MOUNT 18" AFF TO CENTER OF BACKBOX. 1 OF INDICATED: 2 RECEPTACLES IS SWITCHED, REMOVE JUMPER BETWEEN OUTLETS. i 'A2' INDICATES FIXTURE TYPE UPPER CASE LETTER/NUMBER .e. I IC I ( ) F ® ERE E FLUSH WITH FLOOR IN SINGLE GANG FLOOR 20 AMP DUPLEX RECEPTACLE. RECESS LOWER CASE LETTER (i.e. 'U) INDICATES CONNECTION TO INDICATED SWITCH. BOX. COVER SHALL BE BRASS WITH HINGED LID FOR EACH OUTLET OF RECEPTACLE. NOTE: THE FOLLOWING ABBREVIATIONS APPLY TO LIGHTING FIXTURES WHERE F(E) 20 AMP DOUBLE DUPLEX (QUAD) RECEPTACLE. RECESS FLUSH WITH FLOOR IN EM INDICATED: DOUBLE GANG FLOOR BOX. COVER SHALL BE BRASS WITH HINGED LID FOR EACH "EM" INDICATES LIGHT FIXTURE WITH EMERGENCY BATTERY PACK. OUTLET OF RECEPTACLES. 0 FLUORESCENT LIGHT FIXTURE (SEE LIGHT FIXTURE SCHEDULE) GFI 20A SIMPLEX RECEPTACLE WITH GFCI PROTECTION MOUNTED AT HEIGHT OR AS O DOWNLIGHT `P INDICATED. VERIFY RATING AND NEMA CONFIGURATION FOR EQUIPMENT TO BE CONNECTED. WALL SCONCE GFI 20 AMP DUPLEX RECEPTACLE WITH GFCI PROTECTION, RECESS MOUNT 18" AFF TO PENDANT [P CENTER OF BACKBOX. EXIT SIGN WITH BATTERY PACK, MOUNTED WITHIN 6'-8" OF TOP OF OPENING PER NFPA 101:7.10.1.9. FACES AND ARROWS SHALL BE AS GFI 20 AMP DUPLEX RECEPTACLE WITH GFCI PROTECTION, RECESS MOUNT ABOVE SINK, COUNTER, CASEWORK, ETC. OR AT HEIGHT INDICATED. COORDINATE MOUNTING [P IITT INDICATED ON PLANS. CONNECT FIXTURE TO LIGHTING CIRCUIT SERVING HEIGHT WITH ARCHITECTURAL ELEVATIONS AND CONDITIONS PRIOR TO ROUGH -IN. THE AREA, AHEAD OF ANY SWITCHING OR CONTROLS. GFI 20 AMP DOUBLE DUPLEX (QUAD) RECEPTACLE WITH GFCI PROTECTION AND COMMON A f EMERGENCY EGRESS LIGHTING UNIT WITH BATTERY PACK MOUNTED COVER PLATE, RECESS MOUNT 18" AFF TO CENTER OF BACKBOX. T-6" AFF OR AS INDICATED. CONNECT FIXTURE TO LIGHTING CIRCUIT SERVING THE AREA, AHEAD OF ANY SWITCHING OR CONTROLS. ® MULTI -POLE RECEPTACLE FOR APPLIANCE MOUNTED AS INDICATE. COORDINATE EXIT SIGN AND EMERGENCY EGRESS LIGHTING COMBO UNIT WITH ID AMPERAGE RATING, POLES, NEMA CONFIGURATION, ETC. WITH EQUIPMENT TO BE A& BATTERY PACK MOUNTED T-6" AFF. CONNECT FIXTURE TO LIGHTING CONNECTED. CIRCUIT SERVING THE AREA, AHEAD OF ANY SWITCHING OR 20 AMP DUPLEX RECEPTACLE, RECESS MOUNT HORIZONTALLY AT HEIGHT INDICATED. CONTROLS. PASSIVE INFRARED (PIR) OCCUPANCY SENSOR. 360°. 450 SQ. FT. 20 AMP DUPLEX RECEPTACLE MOUNTED 18" AFF, ABOVE COUNTER, OR AT HEIGHT INDICATED RECEPTACLE COORDINATED WITH DATA OUTLET FOR COVERAGE. SENSOR SWITCH CM 10. CONNECT TO LOCAL POWER PACK. (INDICATES COMPUTER USE). MULTI-TECHNLOGY (PIR & ULTRASONIC) OCCUPANCY SENSOR. 360°. 1000 SQ. FT. COVERAGE. SENSOR SWITCH CM-PDT-10. CONNECT TO LOCAL 20 AMP DOUBLE DUPLEX (QUAD) RECEPTACLE MOUNTED 18" AFF, ABOVE COUNTER, POWER PACK. OR AT HEIGHT INDICATED (INDICATES RECEPTACLE COORDINATED WITH DATA EXT. EXTERIOR PASSIVE INFRARED (PIR) OCCUPANCY SENSOR SBO-10-OEX. OUTLET FOR COMPUTER USE). CONNECT TO LOCAL POWER PACK. PROVIDE BOX FOR CEILING MOUNTING. 0 POWER POLE. 2-SECTION (POWER AND COMMUNICATIONS), 2" SQUARE METALLIC, PP OCCUPANCY SENSOR POWER PACK. 20A @120/277VAC. PROVIDE BRUSHED ALUMINUM FINISH. DEVICES MOUNTED AT POLE AS SHOWN. POLE SHALL QUANTITY AS NEEDED. SENSOR SWITCH PP-20-2P. CONNECT TO LOCAL EXTEND FROM FLOOR TO CEILING, SECURE TO CEILING. Ps OCCUPANCY SENSORS. 20 AMP DUPLEX RECEPTACLE, FLUSH MOUNT AT CEILING. SUPPORT BACKBOX FROM LED POWER SUPPLY (TECLED MODEL: VBS-12060DO24) ® STRUCTURE, NOT GRID. COMMUNICATIONS F 2-SECTION FLOOR BOX WITH DUPLEX RECEPTACLE AND DATA SECTION. FLOOR BOX 1-GANG DEEP BOX FOR TELEPHONE OUTLET, RECESS MOUNT 18" TO CENTER SHALL BE FLUSH WITH FLOOR WITH CARPET/TILE PLATE AND TRAP DOOR FOR WIRING OF BACKBOX AFF, ABOVE COUNTER OR AS NOTED. INSTALL 3/4" CONDUIT OUT OF BOX. WITH BUSHINGS AND PULL STRING STUBBED INTO ACCESSIBLE CEILING 0 JUNCTION BOX. FAN RATED IN DWELLING UNITS. SPACE ABOVE BACKBOX. INSTALL BLANK COVERPLATE. NUMBER OF PHONE JACKS AS INDICATED OR INSTALL BLANK COVERPLATE. 'W INDICATES PHONE DC DROP CORD. RECEPTACLE AND BOX SUSPENDED FROM JUNCTION BOX AT CEILING WILL BE WALL MOUNTED, MOUNT AT 48" AFF TO CENTER OF BACKBOX AND ° WITH S/O CORD. PROVIDE STRAIN RELIEF AT EACH END OF CORD. RECEPTACLE INSTALL WALL PHONE PLATE. SHALL BE TYPE OF DEVICE SHOWN. ® (2) GANG DEEP BOX FOR DECORA STYLE DUPLEX RECEPTACLE AND PLUGMOLD WITH RECEPTACLES 12" ON -CENTER. PLUGMOLD SHALL BE TELEVISION OUTLET. COORDINATE MOUNTING HEIGHT AND LOCATION. cmwmw*a NON-METALLIC, 2-PIECE. MOUNT AS INDICATED. VERIFY COLOR OF FINISH, INSTALL 3/4" CONDUIT FOR LOW VOLTAGE WIRING WITH BUSHINGS AND PULL STRING STUBBED INTO ACCESSIBLE CEILING SPACE ABOVE BACKBOX. POWER DISTRIBUTION (REFER TO THE "ELECTRICAL RISER DIAGRAM") INSTALL DECORA COVERPLATE. v 1-GANG DEEP BOX FOR TELEPHONE / DATA OUTLET, RECESS MOUNT 18" TO CENTER OF BACKBOX AFF, ABOVE COUNTER OR AS NOTED. INSTALL 3/4" CONDUIT WITH BUSHINGS AND PULL STRING STUBBED INTO ACCESSIBLE CEILING SPACE ABOVE BACKBOX. INSTALL BLANK COVERPLATE. CABINET. SEE PLANS AND SPECIFICATIONS FOR USAGE AND REQUIREMENTS. MISCELLANEOUS O KEYED NOTE INDICATOR. REFER TO THE "KEYED NOTES" WHERE INDICATED. Q®Q EXHAUST FAN. 'R' SYMBOL INDICATES TO PROVIDE AND INSTALL 10 MINUTE TIME DELAY OFF RELAY. EXHAUST FAN SHALL OPERATE FOR 10 MINUTES AFTER LIGHTING SWITCH IS TURNED OFF. CONNECT HOT LEAD FROM AHEAD OF SWITCH TO RELAY FOR DELAYED OPERATION AND SWITCH LEG TO RELAY FOR NORMAL OPERATION. 'T' SYMBOL INDICATES TO PROVIDE AND INSTALL 277V-120V TRANSFORMER. WATTAGE OF TRANSFORMER VA SHALL BE A MINIMUM 20% GREATER THAN EXHAUST FAN POWER REQUIREMENTS, COORDINATE WITH MECHANICAL CONTRACTOR. r7I MOTORIZED DAMPER. PROVIDE POWER AND MAKE CONNECTIONS AS INDICATED. COORDINATE WITH MECHANICAL CONTRACTOR. sP CEILING MOUNTED SPEAKER LOCATIONS ON A/V SYSTEM ABBREVIATIONS AFF HEIGHT ABOVE FINISHED FLOOR AFG HEIGHT ABOVE FINISHED GRADE ETR EXISTING TO REMAIN EXT EXTERIOR TYPE WIRING DEVICE OR CIRCUIT BREAKER LTG LIGHTING MTR MOTOR N.I.C. NOT IN CONTRACT NF NON -FUSED PH PHASE REL RELOCATED REM TO BE REMOVED REP REPLACE WITH NEW TBR TO BE RELOCATED U.N.O. UNLESS NOTED OTHERWISE VA VOLT AMPERE (POWER) WP WEATHERPROOF ENCLOSURE XFMR TRANSFORMER +48" DEVICE MOUNTED AT HEIGHT INDICATED . . r-/ANCLDU1-%r, J, r[C1,C00 IVIVL/IV 1 Iry FIIVIJ"L_L1 JrnV CO, 3urxFnVC IVIV VIv 1 11V Un�.r\ V1 HOUSE. REFER TO THE "PANELBOARD SCHEDULE". FEEDER OR BRANCH CIRCUIT RACEWAY CONCEALED IN WALL, CEILING. "— FEEDER OR BRANCH CIRCUIT RACEWAY CONCEALED UNDER FLOOR, IN SLAB OR BELOW GRADE. C=l' DISCONNECT SWITCH. PROVIDE DISCONNECT SWITCH AS INDICATED ON THE SCHEDULES. REFER TO PLANS AND SCHEDULES FOR ADDITIONAL REQUIREMENTS. FUSES SHALL BE DUAL ELEMENT TIME DELAY. VERIFY NAMEPLATE RATINGS OF FRAME SIZE AND FUSING OF THE ACTUAL EQUIPMENT TO BE INSTALLED. DRY -TYPE VENTILATED TRANSFORMER. SEE SPECIFICATIONS, PLANS AND RISER FOR REQUIREMENTS. TRANSFORMERS SHALL BE NEMA 1 UNLESS AT THE EXTERIOR OR IN AREAS WHERE WATER MAY BE PRESENT. MOUNT ON 4" HOUSE KEEPING PAD BOLTED TO PAD. MAINTAIN REQUIRED CLEARANCE FROM WALLS OR OBSTRUCTIONS FOR VENTILATION. �f— GROUND TO METAL FRAME OF BUILDING, SLAB STEEL, OTHER MADE ELECTRODES, AND METAL UNDERGROUND WATER PIPE. PROVIDE A MINIMUM OF (3) 3/4" DIA, 10 FOOT LONG COPPER CLAD GROUND RODS LOCATED AT LEAST 6 FEET APART. ALL CONCEALED CONNECTIONS SHALL BE EXOTHERMICALLY WELDED. INTERIOR GROUND RODS SHALL STUB ABOVE FLOOR AT LOCATIONS NOT INTERFERING WITH FOOT TRAFFIC. LOCATE EXTERIOR GROUND ROD ASSEMBLY IN LANDSCAPE AREA OR PROVIDE WELL FOR ACCESS TO EACH GROUND ROD IF ASSEMBLY IS LOCATED IN HARD SURFACE AREAS, SUCH AS CONCRETE, ASPHALT, ETC. PROVIDE BOLTED PRESSURE CLAMP WITH AT LEAST TWO BOLTS ON RODS IN TEST WELLS. ALL GROUND ROD LOCATIONS SHALL BE ACCESSIBLE. VARIABLE FREQUENCY DRIVE. REFER TO SPECIFICATIONS, AND FLOOR PLANS FOR ADDITIONAL ELECTRICAL REQUIREMENTS. VFD SUPPLIED BY MECHANICAL CONTRACTOR (U.N.O.) AND INSTALLED BY ELECTRICAL CONTRACTOR. ALL CONNECTIONS TO VFD, DISCONNECT AND EQUIPMENT SERVED SHALL BE BY THE ELECTRICAL CONTRACTOR. CIRCUIT SHALL UTILIZE METAL CONDUIT TO MINIMIZE RFI NOISE. COMBINATION MOTOR STARTER WITH FUSED DISCONNECT OR CIRCUIT BREAKER DISCONNECT. REFER TO PLANS AND SCHEDULES FOR ADDITIONAL REQUIREMENTS. FUSES SHALL BE DUAL ELEMENT TIME DELAY. VERIFY NAMEPLATE RATINGS OF FRAME SIZE AND FUSING OF THE ACTUAL EQUIPMENT TO BE INSTALLED. LP-1 PANEL HOMERUN/CIRCUIT PANEL DESIGNATION/CIRCUIT NUMBER NOTE: NOT ALL SYMBOLS SHOWN ON LEGEND ARE USED ON FLOOR PLANS. GENERAL NOTES **GENERAL NOTES APPLY TO ALL ELECTRICAL SHEETS** 1. DO NOT SCALE FROM THESE DRAWINGS. 2. ALL WORK SHALL BE PERFORMED IN STRICT ACCORDANCE WITH THE 2017 EDITION OF THE NATIONAL ELECTRICAL CODE (NEC) NFPA 70. 3. ELECTRICAL CONTRACTOR (E.C.) SHALL COORDINATE WORK WITH ALL OTHER TRADES TO ASSURE PROPER CLEARANCES FOR EQUIPMENT AND TO KEEP THE JOB PROGRESSING. 4. DRAWINGS ARE BASED ON FIELD OBSERVATION AND EXISTING DOCUMENTS. REPORT ANY DISCREPANCIES TO THE ENGINEER BEFORE DISTURBING EXISTING INSTALLATION. 5. EXISTING TO REMAIN ELECTRICAL CIRCUITRY DOWNSTREAM AND UPSTREAM OF DEMOLISHED DEVICES SHALL BE MAINTAINED, E.C. SHALL PROVIDE ALL ELECTRICAL COMPONENTS (BOXES, CONDUIT, WIRING, ETC.) AS REQUIRED. 6. ELECTRICAL CONTRACTOR SHALL BE REQUIRED TO CUT, CAPTURE AND EXTEND OR RE-ROUTE EXISTING CONDUITS AND CONDUCTORS AS REQUIRED TO ACCOMMODATE NEW DUCTWORK. COORDINATE WITH MECHANICAL CONTRACTOR AS REQUIRED. 7. REFER TO MECHANICAL DRAWINGS FOR EQUIPMENT NEEDING ELECTRICAL CONNECTIONS (MOTORS, FANS, PUMPS, ETC.). MAKE ALL CONNECTIONS AND PROVIDE APPROPRIATE WIRE, CONDUIT, AND OVERCURRENT PROTECTION FOR ALL EQUIPMENT. INSTALL ANY ELECTRICAL EQUIPMENT (STARTERS, RELAYS, VFD'S, ETC.) FURNISHED BY MECHANICAL CONTRACTOR (DIV 15). COORDINATE EXACT REQUIREMENTS WITH MECHANICAL CONTRACTOR. 8. VOLTAGE DROP: THE CONDUCTORS FOR FEEDERS AND BRANCH CIRCUITS COMBINED SHALL BE SIZED FOR A MAXIMUM OF 5% VOLTAGE DROP TOTAL PER FBC-ENERGY C405.6.3. USE 10 AWG CU. CONDUCTORS FOR 20 AMPERE, 120 VOLT BRANCH CIRCUITS LONGER THAN 75 FEET. USE 10 AWG CU. WHERE WIRE SIZE IS INCREASED IN SIZE FOR VOLTAGE DROP, E.G SHALL BE INCREASED PROPORTIONATELY. PER NEC 250.122 (B). 9. ALL CEILING MOUNTED ITEMS SHALL BE INSTALLED IN ACCORDANCE WITH THE ARCHITECTURAL REFLECTED CEILING PLANS. IF LOCATION FOR AN ITEM IS NOT SHOWN ON THE ARCHITECTURAL REFLECTED CEILING PLANS, VERIFY THE EXACT LOCATION OF THE ITEM WITH THE ARCHITECT PRIOR TO INSTALLATION. 10. WHERE DISCONNECTING MEANS IS NOT PROVIDED "WITHIN SIGHT" FROM EQUIPMENT SERVED, THE OVERCURRENT DEVICE SERVING SUCH EQUIPMENT SHALL HAVE PERMANENT PROVISION TO LOCK IN THE OPEN POSITION PER NEC 422.31 AND 110.25. 11. CONDUIT RUNS SHOWN ARE DIAGRAMMATIC IN NATURE. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR SIZING AND LOCATING PULL BOXES PER NEC. 12. PROVIDE ALL H.I.D. AND FLUORESCENT LIGHT FIXTURES WITH INTEGRAL FUSING. 13. CONNECT EXIT SIGNS AND EGRESS LIGHTS TO LOCAL LIGHTING CIRCUIT AHEAD OF ANY SWITCHING PER NEC 700.12(F). 14. RECEPTACLES IN MECHANICAL ROOMS, ELECTRICAL ROOMS, STORAGE ROOMS, AND JANITOR CLOSETS SHALL BE G.F.C.I. TYPE MOUNTED AT 48" A.F.F. 15, PROVIDE REVISED PHOTOMETRICS FOR ANY SUBSTITUTE FIXTURES. CONDUIT AND CONDUCTOR SCHEDULE C.B. POLES WIRE SIZE P THW) CONDUIT PHASE 20A 1 2412, 1412 E.G. 3/4 10 2W 2 2-#12, 1-#12 E.G. 10 2W 3 3-#12, 1-#12 E.G. 30 3W 3 3412, 1412 N., 1412 E.G. 30 4W 25A 1 2410, 1410 E.G. 3/4 10 2W 2 2-#10, 1-#10 E.G. 10 2W 3 3-#10, 1-#10 E.G. 30 3W 3 3410, 1-#10 N., 1410 E.G. 30 4W 30A 1 2410, 1410 E.G. 3/4 10 2W 2 2-#10, 1-#10 E.G. 10 2W 3 3-#10, 1-#10 E.G. 30 3W 3 3410, 1410 N., 1410 E.G. 30 4W 35A 3 3-#8, 1-#10 E.G. 1 30 3W 3 3-#8, 148 N., 1-#10 E.G. 30 4W 40A 2 248, 1-#10 E.G. 1" 10 2W 3 348, 1410 E.G. 30 3W 3 348, 148 N., 1410 E.G. 30 4W 45A 2 248, 1410 E.G. 1" 10 2W 3 348, 1410 E.G. 30 3W 3 348, 148 N., 1410 E.G. 30 4W 50A 2 248, 1410 E.G. 1" 10 2W 3 348, 1410 E.G. 30 3W 3 348, 148 N., 1410 E.G. 30 4W 60A 2 246, 1410 E.G. 1 10 2W 3 346, 1410 E.G. 30 3W 3 346, 146 N., 1410 E.G. 1 1/4" 30 4W 2 244, 148 E.G. 1" 10 2W 70A 3 344, 148 E.G. 1 1/4" 30 3W 3 3-#4, 1-#4 N., 148 E.G. 30 4W 2 244, 148 E.G. 1" 10 2W 80A 3 344, 148 E.G. 1 1/4" 30 3W 3 344, 144 N., 148 E.G. 30 4W 90A 2 243, 148 E.G. 1 1/4" 10 2W 3 343, 148 E.G. 30 3W 3 343, 143 N., 148 E.G. 30 4W 100A 2 243, 148 E.G. 1 1/4" 10 2W 3 343, 148 E.G. 30 3W 3 343, 143 N., 148 E.G. 30 4W NOTES: 1. ALL CONDUCTORS SHALL BE COPPER 2. ALL CONDUIT SHALL HAVE EQUIPMENT GROUNDING CONDUCTOR INSTALLED. 3. CONDUIT BELOW GRADE OUTSIDE OF BUILDING SHALL BE 1" MINIMUM. 4. SIZING OF CONDUCTORS SHALL BE ALTERED FOR DERATING PER N.E.C. OR VOLTAGE DROP CONSIDERATIONS. 5. SEE RISER DIAGRAM FOR SIZING OF CIRCUITS GREATER THAN 100A. 6. USE #10 AWG, COPPER CONDUCTORS FOR 20 AMPERE, 120 VOLT BRANCH CIRCUITS LONGER THAN 75 FEET. USE #10 AWG, COPPER CONDUCTORS FOR 20 AMPERE, 277 VOLT BRANCH CIRCUITS LONGER THAN 200 FEET. WHERE WIRE SIZE IS INCREASED IN SIZE FOR VOLTAGE DROP, EQUIPMENT GROUND SHALL BE INCREASED PROPORTIONATELY PER NEC 250.122 (B). 7. WHERE MC CABLE IS ALLOWED BY THE AUTHORITY HAVING JURISDICTION, THE CONDUCTORS FOR MC CABLE SHALL BE THHN. JACKET SHALL BE THE MANUFACTURER'S STANDARD SIZE FOR CONDUCTORS UTILIZED. GS JOB iP: SS31 .21 .00 GLOBAL 34%NCrLjirC__Z1NC MEPP ENGINEERING INFO@GLOBAL-SANCHEZ. COM CA#: 6237 B 1 6 MANATEE AVE. E, SUITE 1 B BRADENTON, FL 3420B PHONE: 941-75B-2551 3B25 HENDERSON BLVD., SUITE 1 ❑3 TAMPA, FL 33629 PHONE: 81 3-2B 1 -❑❑❑ 1 C&K ARCHITECTS I INTERIORS architecture. interior design• client services AAC001629 4221 WEST BOY SCOUT BLVD., SUITE 150 TAMPA, FL 33607-5743 813.884.2000 280 WEST CENTRAL AVE. WINTER HAVEN, FL 33880-2957 863.577.2054 �P 3. FE/ •°ENS°'•!rF Q 5083 °• 5 /2021;` W O STATE OF <v � ••'' :r�•OR10P•° Gam? ° sS/ �\41 0 N A L 0 0 s ma 0 0 Z J LL J x a 1,, N J U) q 0 LZ H �.�..� Q/ Z Lu to Q =0 w V °' 0 N � C V m W m J Lu m 0 J m J Q C9 M L0 0, LO ISSUED FOR: PERMIT PROJECT NUMBER 21020 DATE 5.5.21 DRAWING NUMBER Cz Em cz 62 N S, if a m 0 O N V W H Q ELECTRICAL PART 1 -GENERAL 0.01 GENERAL SCOPE A. THIS PROJECT WILL REQUIRE POWER DISTRIBUTION, LIGHTING, AND LIGHTING CONTROLS SYSTEMS AS SHOWN ON THE PLANS AND INCLUDED IN THE SPECIFICATIONS. B. THE SCOPE OF WORK SPECIFIED HEREIN CONSISTS OF PROVIDING (DEFINED AS FURNISH AND INSTALL) ALL LABOR, MATERIALS, EQUIPMENT AND SERVICES REQUIRED TO COMPLETE THE ELECTRICAL AND RELATED WORK INDICATED ON THE DRAWINGS, AS SPECIFIED HEREIN AND SUBJECT TO THE TERMS AND CONDITIONS OF THE CONTRACT. ELECTRICAL WORK INCLUDES, BUT IS NOT LIMITED TO, THE FOLLOWING: • PANELBOARDS • CIRCUIT BREAKERS • DISCONNECT SWITCHES • GROUNDING • RACEWAY FOR POWER DISTRIBUTION • CONDUCTORS FOR POWER DISTRIBUTION • WIRING DEVICES • LIGHTING FIXTURES • RACEWAY FOR COMMUNICATIONS WIRING (VOICE, DATA, CABLE TELEVISION) • CONNECTION OF MOTORS, CONTROL DEVICES AND ELECTRICAL EQUIPMENT FURNISHED BY OTHERS • TESTING • FINAL ACCEPTANCE/WARRANTY • RECORD DRAWINGS C. ITEMS SPECIFIED HEREIN, SHOWN ON THE DRAWINGS, AND/OR REASONABLY INTERPRETED FROM THE DRAWINGS THAT ARE NECESSARY TO COMPLETE THE ELECTRICAL WORK SHALL BE PROVIDED BY THIS DIVISION, WHETHER ITEM IS SPECIFICALLY SHOWN OR NOT. 1.01 GENERAL DOCUMENTS A. ELECTRICAL CONTRACTOR SHALL BECOME THOROUGHLY ACQUAINTED WITH THE PROJECT SITE (e.g. EXISTING CONDITIONS) AND THE ENTIRE CONSTRUCTION DOCUMENTS PACKAGE (e.g. ARCHITECTURAL, STRUCTURAL, CIVIL, MECHANICAL, PLUMBING, FIRE PROTECTION, ELECTRICAL DRAWINGS AND SPECIFICATIONS) BEFORE BID SUBMISSION. WORK OF THE ELECTRICAL CONTRACTOR MUST BE COORDINATED WITH THE WORK OF ALL TRADES. B. THE INTENT OF THE DRAWINGS AND SPECIFICATIONS IS TO DESCRIBE THAT COMPLETE ELECTRICAL AND SPECIAL SYSTEMS ARE REQUIRED. HOWEVER, THE WORK SHALL BE COMPLETE EVEN THOUGH ITEMS MAY NOT BE SPECIFICALLY CALLED FOR OR SHOWN. INSTALLATIONS SHALL MEET ALL GOVERNING CODES, SHALL BE SUBJECT TO THE APPROVAL OF THE ARCHITECT/ENGINEER AND ALL AGENCIES HAVING JURISDICTION. C. WORK NOT COVERED IN THIS SECTION. RECESSES, CHASES, AND OTHER PROVISIONS TO BE MADE IN THE STRUCTURE AS REQUIRED TO ACCOMMODATE ELECTRICAL ITEMS, SUCH AS CONDUIT, PANELS, SWITCHES, ETC, SHALL BE PROVIDED BY THE TRADES CONCERNED. THE ELECTRICAL CONTRACTOR SHALL, HOWEVER, NOTIFY ALL SUCH TRADES OF HIS EXACT REQUIREMENTS AHEAD OF TIME AND SHALL PAY THE COSTS OF ANY CUTTING OR PATCHING CAUSED BY FAILURE TO DO SO. ALL SUCH REMEDIAL WORK SHALL BE DONE ONLY BY MECHANICS OF THE TRADES INVOLVED. 1.02 PERMITS, TAXES, FEES. A. ELECTRICAL CONTRACTOR SHALL OBTAIN ALL GOVERNMENTAL PERMITS, PAY ALL SALES TAXES AND OTHER ASSOCIATED FEES INCLUDING COSTS FOR UTILITY CONNECTIONS, REQUIRED TO PERFORM THE INTENDED ELECTRICAL WORK. ELECTRICAL CONTRACTOR SHALL FILE ALL NECESSARY PLANS, PREPARE ALL DOCUMENTS AND OBTAIN ALL NECESSARY APPROVALS OF ALL GOVERNMENTAL AGENCIES HAVING JURISDICTION. ELECTRICAL CONTRACTOR SHALL OBTAIN ALL REQUIRED CERTIFICATES OF INSPECTION FOR ELECTRICAL WORK AND DELIVER SAME TO THE OWNER AND ARCHITECT BEFORE REQUEST FOR ACCEPTANCE AND FINAL PAYMENT FOR THE WORK. B. ELECTRICAL CONTRACTOR SHALL INCLUDE IN THE WORK, WITHOUT EXTRA COST TO THE OWNER, ALL LABOR, MATERIALS, SERVICES, APPARATUS, OR DRAWINGS NECESSARY TO COMPLY WITH ALL APPLICABLE LAWS, ORDINANCES, RULES AND REGULATIONS, WHETHER OR NOT SHOWN ON DRAWINGS AND/OR SPECIFIED. C. ALL MATERIALS FURNISHED AND ALL WORK INSTALLED SHALL COMPLY WITH THE FOLLOWING: • NATIONAL ELECTRIC CODE 2017 EDITION • FLORIDA BUILDING CODE 7TH EDITION (EFF. 12/31/2020) • APPLICABLE STATE AND LOCAL CODES • NATIONAL BUREAU OF FIRE UNDERWRITERS • REGULATIONS OF THE SERVING UTILITY COMPANIES D. ALL MATERIAL AND EQUIPMENT PROVIDED FOR THE ELECTRICAL WORK SHALL BEAR THE APPROVAL LABEL, OR SHALL BE LISTED, BY UNDERWRITERS' LABORATORIES, INC. 1.03 MEASUREMENTS A. SHOULD THE ELECTRICAL CONTRACTOR DISCOVER ANY DISCREPANCY BETWEEN ACTUAL MEASUREMENTS AND THOSE INDICATED ON THE DRAWINGS, WHICH PREVENTS FOLLOWING GOOD PRACTICE OR THE INTENT OF THE DRAWINGS AND SPECIFICATIONS, HE SHALL NOTIFY THE ARCHITECT/ELECTRICAL ENGINEER THROUGH THE GENERAL CONTRACTOR, AND SHALL NOT PROCEED WITH HIS WORK UNTIL HE HAS RECEIVED INSTRUCTIONS FROM THE ARCHITECT/ELECTRICAL ENGINEER. ALL REQUESTS FOR INFORMATION (RFI) SHALL INCLUDE A PROPOSED SOLUTION. B. PRIOR TO ROUGH -IN OF EQUIPMENT THE GENERAL CONTRACTOR, ARCHITECT AND ELECTRICAL ENGINEER RESERVE THE RIGHT TO RELOCATE ANY PANELBOARD, DISCONNECT, STARTER, LIGHTING FIXTURE, WIRING DEVICE, COMMUNICATIONS OUTLET, ETC THREE (3) FEET IN ANY DIRECTION WITHOUT ANY ADDITIONAL CHARGE, FEE, OR CHANGE ORDER. 1.04 DRAWINGS A. DRAWINGS ARE DIAGRAMMATIC I IC AND INDICATE THE GENERAL LOCATION OF THE ELECTRICAL AND SPECIAL SYSTEMS WORK INCLUDED IN THE CONTRACT. THE ENTIRE CONSTRUCTION DOCUMENTS PACKAGE (DRAWINGS AND SPECIFICATIONS) SHALL BE EXAMINED FOR EXACT LOCATION OF FIXTURES, DEVICES i S AND EQUIPMENT. WHERE ITEMS ARE NOT LOCATED BY THE DRAWINGS OR SPECIFICATIONS OF OTHER CONSULTANTS THEN THE ITEMS SHALL BE LOCATED PER THE ENGINEERING DRAWINGS, HOWEVER, THE DRAWINGS ARE NOT TO BE SCALED. B. ELECTRICAL CONTRACTOR SHALL FOLLOW THE ELECTRICAL DRAWINGS IN LAYING OUT WORK AND SHALL COORDINATE WITH THE DRAWINGS OF OTHER TRADES TO VERIFY SPACES IN WHICH WORK WILL BE INSTALLED. MAINTAIN MAXIMUM HEADROOM AND SPACE AT ALL LOCATIONS. WHERE HEADROOM OR SPACE CONDITIONS APPEAR INADEQUATE, THE ARCHITECT/ELECTRICAL ENGINEER SHALL BE NOTIFIED BEFORE PROCEEDING WITH INSTALLATION. ALL REQUESTS FOR INFORMATION (RFI) SHALL INCLUDE A PROPOSED SOLUTION. C. IF DIRECTED BY THE ARCHITECT/ELECTRICAL ENGINEER, THE ELECTRICAL CONTRACTOR SHALL, WITHOUT EXTRA CHARGE, MAKE REASONABLE MODIFICATIONS IN THE LOCATIONS OF ELECTRICAL WORK AS NEEDED TO PREVENT CONFLICTS WITH WORK OF OTHER TRADES AND FOR PROPER INSTALLATION OF THE WORK. 1.05 SUBSTITUTION OF SPECIFIED EQUIPMENT A. MATERIALS OR PRODUCTS SPECIFIED BY TRADE NAME, MANUFACTURER'S NAME OR CATALOG NUMBER SHALL BE PROVIDED AS SPECIFIED. B. SUBSTITUTIONS ARE NOT PERMITTED WITHOUT WRITTEN APPROVAL FROM THE ENGINEER VIA THE ARCHITECT TEN (10) WORKING DAYS PRIOR TO BID DATE. APPROVALS OF "EQUIVALENT" MATERIALS OR PRODUCTS WILL BE MADE AVAILABLE TO ALL KNOWN BIDDERS AND ISSUED AS AN ADDENDUM (PRIOR TO BID) TO THE CONTRACT DOCUMENTS IF SUBSTITUTED MATERIALS OR PRODUCTS ARE APPROVED BY ARCHITECT/ELECTRICAL ENGINEER. C. ANY CONTRACTOR PROPOSING AN 'EQUIVALENT' MATERIAL OR PRODUCT MUST SUBMIT, WITH THE REQUEST, COMPLETE CATALOG INFORMATION TO PERMIT EVALUATION OF THE PRODUCT. IN THE CASE OF LIGHTING FIXTURES, AN INDEPENDENT TESTING LABORATORY TEST REPORT (NOT THE MANUFACTURER'S) STATING FIXTURE EFFICIENCY AND PERFORMANCE, SHALL ACCOMPANY THE REQUEST. D. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE TO PROVIDE CORRECTIONS TO ALL SITUATIONS CREATED BY THE SUBSTITUTION OF MATERIALS OR PRODUCTS. THE ACCEPTANCE OF SUBSTITUTED MATERIALS OR PRODUCTS, EITHER PRIOR TO BID OR THEREAFTER, DOES NOT RELIEVE THE ELECTRICAL CONTRACTOR FROM THE RESPONSIBILITY TO PROVIDE CORRECTIONS, AT THEIR EXPENSE, FOR ALL DISCREPANCIES AND CONFLICTS CREATED BY THE SUBSTITUTION OF MATERIALS OR PRODUCTS. 1.06 SHOP DRAWINGS A. ELECTRICAL CONTRACTOR SHALL SUBMIT FOR REVIEW AND APPROVAL SHOP DRAWINGS OF ALL MATERIALS OR PRODUCTS REQUIRED TO COMPLETE THE PROJECT AND NO MATERIALS OR PRODUCTS SHALL BE DELIVERED TO THE JOB SITE OR INSTALLED UNTIL THE ELECTRICAL CONTRACTOR HAS ELECTRICAL ENGINEER APPROVED SHOP DRAWINGS. SHOP DRAWINGS FOR MATERIALS OR PRODUCTS SHALL BE SUBMITTED AS ONE COMPLETE PACKAGE. ELECTRICAL CONTRACTOR SHALL FURNISH THE NUMBER OF COPIES REQUIRED BY THE GENERAL AND SPECIAL CONDITIONS OF THE CONTRACT, BUT IN NO CASE LESS THAN SIX (6) IDENTICAL COPIES. SHOP DRAWINGS SHALL BE REVIEWED AND STAMPED BY THE ELECTRICAL AND GENERAL CONTRACTORS FOR COMPLIANCE WITH THE SPECIFIED MATERIALS AND PRODUCTS PRIOR TO SUBMISSION TO THE ARCHITECT/ELECTRICAL ENGINEER. B. SAMPLES, DRAWINGS, SPECIFICATIONS, CUT SHEETS, ETC SUBMITTED FOR REVIEW SHALL BE PROPERLY LABELED AND SHALL INDICATE THE SPECIFIC ITEM FOR WHICH THE ELECTRICAL CONTRACTOR IS PROPOSING TO PROVIDE. C. "NO EXCEPTION" RENDERED ON SHOP DRAWINGS SHALL NOT BE CONSIDERED AS A GUARANTEE THAT THE MATERIAL OR PRODUCTS COMPLY WITH THE BUILDING CONDITIONS OR MEASUREMENTS. WHERE SHOP DRAWINGS ARE REVIEWED, SAID "NO EXCEPTION" DOES NOT IN ANY WAY RELIEVE THE ELECTRICAL CONTRACTOR FROM THE RESPONSIBILITY OF PROVIDING LABOR, MATERIAL OR PRODUCTS REQUIRED TO PERFORM THE WORK AS REQUIRED BY THE DRAWINGS AND SPECIFICATIONS. D. SHOP DRAWINGS SUBMITTALS ARE REQUIRED ON ELECTRICAL DISTRIBUTION EQUIPMENT, PANELBOARDS, TRANSFORMERS, CONDUIT, CONDUCTORS (WIRE), CIRCUIT BREAKERS, DISCONNECT SWITCHES, WIRING DEVICES, FLOOR BOXES, LIGHT FIXTURES, TIMECLOCKS, CONTACTORS AND SURGE PROTECTION DEVICES (SPD) PART 2-PRODUCTS 2.01 SERVICE ENTRANCE A. SERVICE ENTRANCE SHALL BE UNDERGROUND FROM THE POWER COMPANY TRANSFORMER OR OTHER SERVICE POINT TO THE SERVICE ENTRANCE METER/ EQUIPMENT SHOWN ON THE ELECTRICAL RISER DIAGRAM AND/OR SITE PLAN. VOLTAGE/PHASE OF INCOMING POWER SHALL BE AS INDICATED ON THE ELECTRICAL RISER DIAGRAM AND SHALL BE VERIFIED WITH THE SERVING UTILITY COMPANY PRIOR TO BID. 2.02 PANELBOARDS A. PROVIDE POWER DISTRIBUTION EQUIPMENT AS INDICATED ON THE ELECTRICAL RISER DIAGRAM AND PANEL SCHEDULES. PANELBOARDS SHALL BE OF DEAD FRONT CONSTRUCTION AND SHALL BE MANUFACTURED BY SQUARE "D", GENERAL ELECTRIC, CUTLER -HAMMER OR SIEMENS. B. PANELBOARDS SHALL NOT BE LESS THAN 20" WIDE AND SHALL BE FABRICATED FROM CODE GAUGE STEEL WITH A POST FABRICATION APPLIED GRAY ENAMEL FINISH. C. PANELBOARD AND INTERNAL COMPONENTS SHALL BE CONSTRUCTED AND U.L. LISTED TO WITHSTAND THE SYMMETRICAL SHORT CIRCUIT AMPERES INDICATED ON THE ELECTRICAL RISER DIAGRAM OR PANEL SCHEDULES. D. WIRE GUTTER SPACE SHALL COMPLY WITH U.L. AND NEC STANDARDS FOR PANELBOARDS. E. PANELBOARDS SHALL BE SURFACE OR FLUSH MOUNTED AS SHOWN ON PANEL SCHEDULES AND/OR FLOOR PLANS. PANEL SHALL BE EQUIPPED WITH RECESSED HINGES, FLUSH LOCK WITH CATCH AND SPRING LOADED DOOR PULL. ALL LOCKS SHALL BE KEYED A LIKE. TURN OVER ALL KEYS TO OWNER. F. PROVIDE TYPED CIRCUIT IDENTIFICATION CARD INSIDE EACH PANEL, BASE DESCRIPTION ON LOAD SERVED. G. PROVIDE LAMINATED, ENGRAVED PLASTIC NAMEPLATE WITH WHITE LETTERS STATING PANELBOARD NAME MOUNTED ON FRONT OF EACH PANEL. MOUNT NAMEPLATE WITH METAL FASTNERS. MINIMUM NAMEPLATE SIZE SHALL BE 3" WIDE BY 1-1/2" HIGH WITH 1/2" HIGH ENGRAVED LETTERS. PROVIDE BLACK NAMEPLATE COLOR FOR NORMAL AND RED NAMEPLATE COLOR FOR EMERGENCY PANELBOARDS OR COLOR AS REQUIRED TO MEET OWNERS STANDARD NAMEPLATE COLORS. 2.03 CIRCUIT BREAKERS: A. CIRCUIT BREAKERS SHALL BE QUICK -MAKE, QUICK -BREAK, THERMAL MAGNETIC MOLDED CASE OF FRAME SIZE, NUMBER OF POLES AND TRIP RATINGS AS SHOWN ON THE ELECTRICAL RISER DIAGRAM AND/OR PANEL SCHEDULES. MULTI -POLE BREAKERS SHALL HAVE A SINGLE HANDLE TO TRIP ALL POLES AT ONCE, CIRCUIT BREAKERS SHALL BE FROM THE SAME MANUFACTURER AS THE POWER DISTRIBUTION EQUIPMENT. PROVIDE CIRCUIT BREAKERS WITH GROUND FAULT AND ARC FAULT PROTECTION WHERE REQUIRED. 2.04 DISCONNECT SWITCHES A. DISCONNECT SWITCHES SHALL BE U.L. LISTED AND FROM SAME MANUFACTURER AS POWER DISTRIBUTION EQUIPMENT. SWITCH BLADES SHALL BE FULLY VISIBLE IN THE "OFF" POSITION WITH THE DOOR OPEN. ALL CURRENT CARRYING PARTS SHALL BE PLATED T RESIST N I O SIS CORROSION. B. SWITCHES SHALL BE QUICK -MAKE, QUICK -BREAK Q 1 QUIC SUCH THAT DURING NORMAL OPERATION, THE CONTACTS SHALL NOT BE CAPABLE OF BEING RESTRAINED BY THE OPERATING HANDLE AFTER THE CLOSING OR OPENING ACTION OF THE CONTACTS HAS STARTED. THE HANDLE AND MECHANISM SHALL BE AN INTEGRAL PART OF THE BOX, NOT THE COVER, WITH POSITIVE PADLOCKING PROVISIONS IN THE "OFF" POSITION. C. PROVIDE HEAVY-DUTY, NEMA-1 ENCLOSURE UNLESS NEMA-3R (RAIN PROOF) IS REQUIRED BY THE SWITCH LOCATION. ENCLOSURES SHALL BE PROVIDED WITH A POST FABRICATION APPLIED GRAY ENAMEL FINISH. D. FUSIBLE SWITCHES SHALL BE CAPABLE OF FIELD CONVERSION FROM STANDARD CLASS-H FUSE SPACING TO CLASS-J FUSE SPACING WITHOUT AFFECTING THE U.L. LISTING. THE SWITCH MUST ALSO ACCEPT CLASS-R FUSES AND HAVE A FIELD INSTALLABLE U.L. LISTED REJECTION FEATURE TO REJECT ALL FUSES EXCEPT CLASS-R. THE U.L. LISTED SHORT CIRCUIT RATING, WHEN EQUIPPED WITH CLASS-J OR CLASS-R FUSES, SHALL BE 200,000AMPERES RMS SYMMETRICAL. 2.05 GROUNDING AND BONDING A. PROVIDE A SINGLE, COMPLETE GROUNDING NETWORK FOR THE ENTIRE ELECTRICAL AND SPECIAL SYSTEMS WHICH COMPLIES WITH NEC REQUIREMENTS. B. SERVICE NEUTRAL AND EQUIPMENT GROUND SHALL BE CONNECTED AT ONE POINT INSIDE THE MAIN DISTRIBUTION PANEL WITH ONE CONTINUOUS CONDUCTOR FROM THIS LOCATION TO THREE 10 FOOT LONG DRIVEN GROUND RODS LOCATED IN A TRIANGULAR PATTERN, TO BUILDING STEEL AND TO METAL WATER PIPE. C. PROVIDE BONDING CONNECTION WITH GROUND BUSHING TO CONDUIT FROM DISTRIBUTION PANEL TO THE BREAKERS AND PANELS SERVED. D. CONNECTIONS TO GROUND RODS SHALL BE MADE WITH EXOTHERMIC WELDS. PROVIDE TEST WELL OVER EACH GROUND ROD. ELECTRICAL SPECIFICATIONS - DIVISION 16 2.06 CONDUIT FOR POWER DISTRIBUTION WIRING A. WIRING FOR POWER DISTRIBUTION SHALL BE INSTALLED IN RIGID METALLIC (GALVANIZED STEEL) CONDUIT (RMC), INTERMEDIATE METAL CONDUIT (IMC), ELECTRICAL METALLIC TUBING (EMT), FLEXIBLE METAL CONDUIT OR SCHEDULE 40/80 PVC CONDUIT. PROVIDE THE CONDUIT TYPE INDICATED IN THIS SPECIFICATION WHERE CONDUIT TYPE IS NOT NOTED ON THE DRAWINGS. B. RIGID GALVANIZED STEEL (RGS) CONDUIT WITH THREADED FITTINGS SHALL BE PROVIDED ABOVE GROUND AT EXPOSED INTERIOR AND EXTERIOR LOCATIONS WHERE CONDUIT MAY BE SUBJECTED TO PHYSICAL DAMAGE FROM VEHICLES, MAINTENANCE EQUIPMENT, ETC. PROVIDE LARGE RADIUS SWEEP ELBOWS FOR RGS CONDUIT. C. IMC CONDUIT WITH THREADED FITTINGS SHALL BE PROVIDED IN ABOVE GROUND, EXPOSED INTERIOR AND EXTERIOR LOCATIONS WHERE CONDUIT WILL NOT BE SUBJECTED TO PHYSICAL DAMAGE, BUT WILL BE EXPOSED TO RAIN WATER, HAZARDOUS CONDITIONS, ETC. THREADLESS FITTINGS FOR IMC IS NOT ACCEPTABLE. D. EMT CONDUIT WITH SET SCREW FITTINGS SHALL BE PROVIDED IN ABOVE GROUND INTERIOR LOCATIONS WHERE CONDUIT WILL NOT BE SUBJECTED TO PHYSICAL DAMAGE AND WILL REMAIN COMPLETELY DRY DURING ALL WEATHER CONDITIONS. E. EMT CONDUIT SHALL NOT BE USED IN LOCATIONS WHERE CONDUIT COULD BE EXPOSED TO DIRECT/INDIRECT RAINWATER/LIQUIDS, WIND DRIVEN RAIN, HOSE DOWN AREAS, OPEN AIR AREAS WITHOUT AIR CONDITIONING (UNLESS CONDUIT WILL REMAIN COMPLETELY DRY DURING ALL WEATHER CONDITIONS) AND AREAS WHERE RAINWATER/LIQUIDS MIGHT DRIP OR RUN INTO CONDUIT, BACKBOXES OR DEVICES. F. SCHEDULE 80 PVC CONDUIT SHALL BE USED FOR UNDERGROUND SERVICE ENTRANCE FEEDERS AND ALL CONDUIT BELOW ROADWAYS U.N.O. ON THE RISER DIAGRAMS AND/OR FLOOR PLANS. PROVIDE LARGE RADIUS RIGID GALVANIZED STEEL ELBOWS FOR SCHEDULE 80 PVC CONDUIT. COAT RGS ELBOWS WITH BLACK MASTIC. G. SCHEDULE 40 PVC CONDUIT SHALL BE USED FOR ALL UNDERGROUND FEEDERS AND WIRING EXCEPT FOR SERVICE ENTRANCE FEEDERS AND UNDER ROADWAYS. PROVIDE LARGE RADIUS RIGID GALVANIZED STEEL ELBOWS FOR SCHEDULE 40 PVC CONDUIT WHERE OVERALL CONDUIT RUN IS GREATER THAN 100 FEET. COAT RGS ELBOWS WITH BLACK MASTIC. H. PVC CONDUIT SHALL NOT BE USED MORE THAN SIX INCHES ABOVE FINISHED GRADE IN EITHER INTERIOR OR EXTERIOR LOCATIONS. PVC CONDUIT SHALL TRANSITION TO METAL CONDUIT NO MORE THAN SIX INCHES ABOVE GRADE. I. ALL PVC CONNECTIONS SHALL BE WATERTIGHT. J. FLEXIBLE METAL CONDUIT SHALL BE USED TO CONNECT LIGHTING FIXTURES AND EQUIPMENT SUBJECT TO VIBRATION, INCLUDING A/C EQUIPMENT, MOTORS, TRANSFORMERS, ETC. PROVIDE LIQUID TIGHT FLEXIBLE METAL CONDUIT AND FITTINGS FOR EXTERIOR APPLICATIONS. K. CONCEAL ALL CONDUIT IN WALLS, PARTITIONS, OR CEILINGS IN FINISHED AREAS. CONDUIT SHALL NOT BE EXPOSED IN FINISHED AREAS EXCEPT WHEN ABSOLUTELY NECESSARY. CONDUIT SHALL BE STRAIGHT AND PARALLEL TO BUILDING LINES. L. DURING CONSTRUCTION CONDUIT SHALL BE PROTECTED AGAINST DAMAGE AND ENTRANCE OF WATER, DIRT OR FOREIGN MATERIAL WITH WATERTIGHT CAPS. FIRE RATED ASSEMBLIES SHALL BE PROVIDED WHERE CONDUIT PASSES THROUGH FIRE RATED CONSTRUCTION. REFER TO THE ARCHITECTURAL DRAWINGS FOR EXACT LOCATIONS OF FIRE RATED CONSTRUCTION. REFER TO THE FIRE STOP PENETRATION DETAILS ON THE ELECTRICAL DRAWINGS. M. INSULATING BUSHINGS WITH DOUBLE LOCK -NUTS SHALL BE USED WHEREVER A NEW CONDUIT 1-1/4" DIA OR LARGER ENTERS A BOX, PANEL, DISCONNECT OR ELECTRICAL EQUIPMENT. N. CONDUIT SIZES SHOWN ON THE DRAWINGS AND SCHEDULES ARE THE MINIMUM SIZES REQUIRED. LARGER SIZE CONDUIT TO FACILITATE WIRE PULLS, ETC, IS PERMITTED. 2.07 CONDUCTORS A. PROVIDE 75 DEGREE CELSIUS (167 DEGREE FAHRENHEIT) TYPE THHW, THW, THWN, OR XHHW INSULATED COPPER CONDUCTORS RATED AT 600V FOR POWER DISTRIBUTION WIRING. CONDUIT WIRE FILL SHOWN ON THE DRAWINGS AND FEEDER SCHEDULES ARE BASED ON TYPE THW WIRE UNLESS NOTED OTHERWISE. B. CONDUCTORS UP TO AND INCLUDING NO. 10 AWG SHALL BE SOLID AND CONDUCTORS NO. 8 AWG AND LARGER SHALL BE STRANDED. MINIMUM CONDUCTOR SIZE SHALL BE NO. 12 AWG. CONDUCTORS SHALL BE CONTINUOUS BETWEEN EQUIPMENT AND DEVICES. SPLICES ARE TO BE MADE ONLY IN ACCESSIBLE JUNCTION OR OUTLET BOXES AND SHOULD BE KEPT TO A MINIMUM. SPLICES ON NO.12 AND NO.10 WIRE SHALL BE MADE WITH PRESSURE CONNECTORS CAPABLE OF CARRYING FULL WIRE CAPACITY. SPLICES ON NO.8 WIRE AND LARGER SHALL BE MADE WITH SOLDERLESS LUGS WRAPPED WITH BOTH RUBBER AND PLASTIC ELECTRICAL TAPE. CONNECTIONS TO FIXED EQUIPMENT TERMINALS ARE TO BE MADE WITH SOLDERLESS LUGS. C. ALL NEW CONDUIT USED FOR POWER DISTRIBUTION SHALL CONTAIN AN EQUIPMENT GROUNDING CONDUCTOR. CONDUIT RACEWAY SHALL NOT BE USED IN PLACE OF A GROUNDING CONDUCTOR. D. MC TYPE CABLE MAY BE UTILIZED FOR FINAL EQUIPMENT CONNECTIONS IF ALLOWED BY THE AUTHORITY HAVING JURISDICTION. MC TYPE CABLE SHALL NOT BE USED FOR HOMERUNS TO PANELS. E. ROMEX (NM) CABLE MAY BE UTILIZED IN ONE -AND TWO-FAMILIY DWELLINGS AND MULTI -FAMILY DWELLINGS PERMITTED TO BE OF TYPES III, IV, AND V CONSTRUCTION, PER NEC 334.10. 2.08 WIRING DEVICES A. THE EXTENT OF WIRING DEVICE WORK IC O K IS INDICATED ON THE DRAWINGS. WIRING DEVICES ARE DEFINED AS SINGLE DISCRETE UNITS OF ELECTRICAL DISTRIBUTION SYSTEMS THAT ARE INTENDED T B NOT I O CARRY BUT O UTILIZE ELECTRIC ENERGY. TYPES OF WIRING DEVICES IN THIS SECTION INCLUDE: • RECEPTACLES • GROUND FAULT CIRCUIT INTERRUPTERS • ARC FAULT CIRCUIT INTERRUPTERS • LIGHT SWITCHES B. PROVIDE WHITE COLORED WIRING DEVICES AND MATCHING THERMOPLASTIC COVERPLATES UNLESS NOTED OTHERWISE. FINAL COLOR SELECTION SHALL BE COORDINATED WITH OWNER/ARCHITECT PRIOR TO BID. C. QUALITY ASSURANCE 1. NEC COMPLIANCE: COMPLY WITH NEC AS APPLICABLE TO INSTALLATION AND WIRING OF ELECTRICAL WIRING DEVICES, 2. UL COMPLIANCE: COMPLY WITH APPLICABLE REQUIREMENTS OF U.L. 20, 486A, 498 AND 943 PERTAINING TO INSTALLATION OF WIRING DEVICES. PROVIDE WIRING DEVICES WHICH ARE U.L. LISTED AND LABELED. 3. IEEE COMPLIANCE: COMPLY WITH APPLICABLE REQUIREMENTS OF IEEE STANDARD 241, "RECOMMENDED PRACTICE FOR ELECTRIC POWER SYSTEMS IN COMMERCIAL BUILDINGS", PERTAINING TO ELECTRICAL WIRING SYSTEMS. 4. NEMA COMPLIANCE: COMPLY WITH APPLICABLE PORTIONS OF NEMA STANDARDS PUBLICATION NUMBER WD-1, "GENERAL PURPOSE WIRING DEVICES", WD-2, "SEMICONDUCTOR DIMMERS FOR INCANDESCENT LAMPS", AND WD-5, "SPECIFIC PURPOSE WIRING DEVICES". D. RECEPTACLES 1. SIMPLEX: PROVIDE SPECIFICATION GRADE 20-AMPERE, 125 VOLT, HEAVY-DUTY, 2-POLE, 3-WIRE, RECEPTACLE WITH GREEN HEXAGONAL EQUIPMENT GROUND SCREW AND METAL PLASTER EARS DESIGNED FOR SIDE AND BACK WIRING WITH SPRING LOADED, SCREW ACTIVATED PRESSURE PLATE IN NEMA 5-20R CONFIGURATION UNLESS NOTED OTHERWISE. COORDINATE ALL "SPECIAL" RECEPTACLES WITH THE EQUIPMENT SERVED PRIOR TO ROUGH -IN. PROVIDE RECEPTACLE RATING AND CONFIGURATION TO MATCH EQUIPMENT SERVED. 2. DUPLEX: PROVIDE SPECIFICATION GRADE 20-AMPERE, 125 VOLT, HEAVY-DUTY, 2-POLE, 3-WIRE, RECEPTACLE WITH GREEN HEXAGONAL EQUIPMENT GROUND SCREW AND METAL PLASTER EARS DESIGNED FOR SIDE AND BACK WIRING WITH SPRING LOADED, SCREW ACTIVATED PRESSURE PLATE IN NEMA 5-20R CONFIGURATION. E. GROUND -FAULT CIRCUIT INTERRUPTERS 1. PROVIDE SPECIFICATION GRADE "FEED-THRU" TYPE GROUND -FAULT CIRCUIT INTERRUPTERS, WITH HEAVY-DUTY DUPLEX RECEPTACLES, CAPABLE OF PROTECTING CONNECTED DOWNSTREAM RECEPTACLES ON SINGLE CIRCUIT, AND OF BEING INSTALLED IN A 2-3/4" DEEP OUTLET BOX WITHOUT ADAPTER, GROUNDING TYPE U.L. RATED CLASS A, GROUP 1, RATED 20-AMPERES, 120-VOLTS, 60 HZ, WITH SOLID-STATE GROUND -FAULT SENSING AND SIGNALING, WITH 5 MILLIAMPERES GROUND -FAULT TRIP LEVEL, EQUIP WITH NEMA 5-20R CONFIGURATION. F. MANUAL LIGHT SWITCHES 1. PROVIDE DECORA TYPE IN FINISHED SPACES AND DWELLING UNITS. COORDINATE WITH ARCHITECT/OWNER. 2. SINGLE AND TWO POLE: PROVIDE HARD USE SPECIFICATION GRADE RECESS MOUNTED SINGLE AND TWO -POLE QUIET TOGGLE SWITCHES, 20-AMPERE, 120/277 VOLTS AC. PROVIDE WITH MOUNTING YOKE INSULATED FROM MECHANISM, PLASTER EARS, SWITCH HANDLE, AND SIDE -WIRED SCREW TERMINALS. 3. THREE AND FOUR WAY: PROVIDE HARD USE SPECIFICATION GRADE RECESS MOUNTED 3 AND 4-WAY AC QUIET SWITCHES, 20-AMPERES, 120/277 VOLTS PROVIDE WITH MOUNTING YOKE INSULATED FROM MECHANISM, PLASTER EARS, SWITCH HANDLE, SIDE -WIRED SCREW TERMINALS, WITH BREAK -OFF TAB FEATURES, WHICH ALLOWS WIRING WITH SEPARATE OR COMMON FEED. 2.09 LIGHTING FIXTURES A. ELECTRICAL CONTRACTOR SHALL PROVIDE, WIRE AND LAMP ALL LIGHTING FIXTURES SHOWN ON SITE PLAN, FLOOR PLANS AND LIGHTING FIXTURE SCHEDULE. AT SUBSTANTIAL COMPLETION, ELECTRICAL CONTRACTOR SHALL CLEAN DUST, DEBRIS, FINGERPRINTS, ETC FROM ALL FIXTURE LENSES, LOUVERS, AND REFLECTORS AND SHALL REPLACE ALL LAMPS, BALLASTS, ETC THAT ARE NOT WORKING. B. ELECTRICAL CONTRACTOR SHALL REVIEW THE ARCHITECTURAL DRAWINGS (SECTIONS, ELEVATIONS, DETAILS, ETC.) FOR LIGHTING FIXTURES WHICH MAY BE SHOWN AND SHALL NOTIFY THE ARCHITECT/ ENGINEER PRIOR TO BID IF FIXTURES APPEAR ON THE ARCHITECTURAL DRAWINGS THAT DO NOT APPEAR ON THE ELECTRICAL DRAWINGS. C. ELECTRICAL CONTRACTOR SHALL PROVIDE AND INSTALL PATH OF EGRESS LIGHTING AND EXIT SIGNAGE AS SHOWN ON THE PLANS AND AS REQUIRED BY APPLICABLE LIFE SAFETY CODE(S). 2.10 LIGHTING CONTROLS A. INTERIOR. PROVIDE A COMPLETE, AUTOMATIC LIGHTING CONTROLS SYSTEM TO SHUT OFF INTERIOR LIGHTING IN COMPLIANCE WITH FBC ENERGY SECTION C405. THE SYSTEM SHALL FUNCTION ON EITHER OF THE FOLLOWING: 1. OCCUPANCY SENSOR(S) THAT SHALL TURN LIGHTING OFF WITHIN 20 MINUTES OF ALL OCCUPANTS VACATING THE SPACE. 2. A SCHEDULED BASIS THAT TURNS LIGHTING OFF AT A PROGRAMMED TIME OF DAY. PROVIDE INDICATION 5 MINUTES PRIOR TO TURNING LIGHTING OFF TO ALLOW OCCUPANTS TO MANUALLY OVERRIDE SCHEDULE. B. EXTERIOR. PROVIDE TIMECLOCK(S) FOR EXTERIOR LIGHTING CONTROL, TIME CLOCKS SHALL BE 7-DAY, 24-HOUR MECHANICAL OR ELECTRONIC WITH CARRYOVER PROVISIONS FOR A MINIMUM OF 16 HOURS. PROVIDE PHOTOCELL FOR AUTOMATIC FIXTURE SWITCHING WHERE INDICATED ON SITE AND FLOOR PLANS. PHOTOCELL SHALL BE RATED FOR REQUIRED LOAD AND VOLTAGE WITH BUILT-IN DELAY FOR TRANSIENT LIGHT FLASHES AND LIGHT LEVEL ADJUSTMENT. C. DOCUMENTS CERTIFYING THAT THE INSTALLED LIGHTING CONTROLS MEET THE DOCUMENTED PERFORMANCE CRITERIA OF FBC-ENERGY SECTION C405 SHALL BE PROVIDED TO THE BUILDING OWNER WITHIN 90 DAYS FROM THE DATE OF RECEIPT OF THE CERTIFICATE OF OCCUPANCY. 2.11 EQUIPMENT FURNISHED BY OTHERS A. ELECTRICAL CONTRACTOR SHALL PROVIDE ELECTRICAL SERVICE TO EQUIPMENT PROVIDED BY OTHERS INCLUDING, BUT NOT LIMITED TO, CIRCUIT BREAKERS, CONDUIT, WIRE, DISCONNECT SWITCHES, ETC AS REQUIRED BY OTHERS. 2.12 MOTOR CONTROLLERS A. PROVIDE FULL -VOLTAGE, NON -REVERSING, ACROSS -THE -LINE, MAGNETIC MOTOR CONTROLLER(S). COORDINATE THE FEATURES OF EACH MOTOR CONTROLLER WITH THE RATINGS AND CHARACTERISTICS OF THE SUPPLY CIRCUIT, THE MOTOR, THE REQUIRED CONTROL SEQUENCE, THE DUTY CYCLE OF THE MOTOR, DRIVE, AND LOAD, AND THE PILOT DEVICE, AND CONTROL CIRCUITING AFFECTING CONTROLLER FUNCTIONS. PROVIDE CONTROLLERS THAT ARE HORSEPOWER RATED TO SUIT THE MOTOR CONTROLLED. B. CONTACTS SHALL OPEN EACH UNGROUNDED CONNECTION TO THE MOTOR. C. OVERLOAD RELAYS: AMBIENT -COMPENSATED TYPE WITH INVERSE -TIME -CURRENT CHARACTERISTIC. PROVIDE WITH HEATERS OR SENSORS IN EACH PHASE MATCHED TO NAMEPLATE FULL -LOAD CURRENT OF THE SPECIFIC MOTOR TO WHICH CONNECTED WITH APPROPRIATE ADJUSTMENT FOR DUTY CYCLE. D. ENCLOSURES: FOR INDIVIDUALLY MOUNTED MOTOR CONTROLLERS AND CONTROL DEVICES, COMPLY WITH NEMA STANDARD 250, "ENCLOSURES FOR ELECTRICAL EQUIPMENT (1000 VOLTS MAXIMUM)." PROVIDE ENCLOSURES SUITABLE FOR THE ENVIRONMENTAL CONDITIONS AT THE CONTROLLER LOCATION. E. PROVIDE CONTROL POWER TRANSFORMER INTEGRAL WITH CONTROLLER WHERE NO OTHER SUPPLY OF CONTROL POWER TO CONTROLLER IS INDICATED. PROVIDE CONTROL POWER TRANSFORMER WITH ADEQUATE CAPACITY TO OPERATE CONNECTED PILOT, INDICATING AND CONTROL DEVICES, F. COMBINATION CONTROLLER: SWITCH TYPE; FUSED, QUICK -MAKE, QUICK -BREAK SWITCH, FACTORY ASSEMBLED WITH CONTROLLER AND ARRANGED TO DISCONNECT IT. PROVIDE REJECTION -TYPE FUSE CLIPS AND FUSES RATED PER MANUFACTURERS RECOMMENDATION. INTERLOCK SWITCH WITH UNIT COVER OR DOOR. G. AUXILIARY CONTROL DEVICES SHALL BE FACTORY INSTALLED IN CONTROLLER ENCLOSURE. H. AUTOMATIC SELECTOR SWITCHES: INSTALL IN COVERS OF CONTROLLERS OF MOTORS STARTED AND STOPPED BY AUTOMATIC CONTROLS OR INTERLOCKS WITH OTHER EQUIPMENT. MAKE CONTROL CONNECTIONS SO ONLY THE MANUAL AND AUTOMATIC CONTROL DEVICES THAT HAVE NO SAFETY FUNCTIONS WILL BE BYPASSED WHEN THE SWITCH IS IN THE HAND POSITION. CONNECT MOTOR CONTROL CIRCUIT IN BOTH HAND AND AUTOMATIC POSITIONS FOR SAFETY TYPE CONTROL DEVICES SUCH AS "LOW"AND "HIGH" PRESSURE CUTOUTS, HIGH TEMPERATURE CUTOUTS, AND MOTOR OVERLOAD PROTECTORS. MAKE CONTROL CIRCUIT CONNECTIONS TO A HAND -OFF -AUTOMATIC SWITCH OR TO MORE THAN ONE AUTOMATIC CONTROL DEVICE IN ACCORDANCE WITH MANUFACTURER PROVIDED WIRING DIAGRAM. 2.13 RACEWAY FOR COMMUNICATIONS WIRING A. REFER TO THE COMMUNICATIONS RISER DIAGRAM AND ELECTRICAL SYMBOL LEGEND FOR ADDITIONAL REQUIREMENTS. B. PROVIDE CONDUIT, BACKBOX, BLANK COVERPLATE AND PULL STRING FOR EACH OUTLET INDICATED ON CONSTRUCTION DOCUMENTS. PROVIDE BUSHING ON ENDS OF CONDUIT. DEVICES AND WIRING PROVIDED BY OTHERS. C. PROVIDE EACH CONDUIT WITH PULL STRING STUBBED FROM BACKBOX INTO ACCESSIBLE CEILING SPACE (I.E., LAY -IN CEILING TILE) ABOVE EACH OUTLET. D. PROVIDE CONDUIT WITH PULL STRING ROUTED FROM EACH BACKBOX TO CLOSEST COMMUNICATIONS BACKBOARD (OR TERMINAL CABINET) ON THE FLOOR WHERE OUTLET IS LOCATED U.N.O. E. PROVIDE CONDUIT, (1) 2" MINIMUM, ABOVE INACCESSIBLE CEILINGS AND COVERED BREEZEWAYS. EXTEND CONDUIT INTO ACCESSIBLE CEILING SPACE AT EACH END. F. ROUTE CONDUIT THROUGH RATED WALLS AND FLOORS USING U.L. APPROVED FIRE RATED PENETRATION MATERIALS. PART 3 - EXECUTION 3.01 COOPERATION WITH OTHER TRADES A. ELECTRICAL CONTRACTOR SHALL GIVE FULL COOPERATION TO OTHER TRADES AND SHALL FURNISH IN WRITING TO THE ARCHITECT/ELECTRICAL ENGINEER ANY INFORMATION NECESSARY TO PERMIT THE WORK OF OTHER TRADES TO BE INSTALLED SATISFACTORILY AND WITH THE LEAST POSSIBLE INTERFERENCE OR DELAY. B. WHERE ELECTRICAL WORK WILL BE INSTALLED IN CLOSE PROXIMITY TO, OR MAY INTERFERE WITH, WORK OF OTHER TRADES THE CONTRACTORS SHALL ASSIST EACH OTHER IN WORKING OUT A SATISFACTORY SPACE FOR EACH CONTRACTORS WORK. IF DIRECTED BY THE ARCHITECT/ELECTRICAL ENGINEER, THE ELECTRICAL CONTRACTOR SHALL PREPARE COMPOSITE WORKING DRAWINGS AND SECTIONS AT SUITABLE SCALE, NOT LESS THAN 1/4" = 1'-0", CLEARLY SHOWING HOW WORK IS TO BE INSTALLED IN RELATION TO WORK OF OTHER TRADES. IF THE ELECTRICAL CONTRACTOR INSTALLS HIS WORK BEFORE COORDINATING WITH OTHER TRADES, OR CAUSES ANY INTERFERENCE WITH WORK OF OTHER TRADES, THE ELECTRICAL CONTRACTOR SHALL MAKE THE NECESSARY CHANGES IN THE ELECTRICAL WORK TO CORRECT THE CONDITIONS WITHOUT EXTRA CHARGE. C. ELECTRICAL CONTRACTOR SHALL FURNISH TO OTHER TRADES, AS REQUIRED, ALL NECESSARY TEMPLATES, PATTERNS, AND ASSEMBLY DETAILS FOR THE PROPER INSTALLATION OF WORK AND FOR THE PURPOSE OF COORDINATING ADJACENT WORK. 3.02 SCAFFOLDING, RIGGING, HOISTING A. ELECTRICAL CONTRACTOR SHALL PROVIDE ALL SCAFFOLDING, RIGGING AND HOISTING NECESSARY FOR ERECTION AND DELIVERY INTO THE PREMISES OF ALL ELECTRICAL EQUIPMENT. REMOVE SAME FROM PREMISES WHEN NO LONGER REQUIRED. 3.03 EXCAVATING AND BACKFILLING A. ELECTRICAL CONTRACTOR SHALL PROVIDE ALL TRENCH AND PIT EXCAVATION AND BACKFILLING REQUIRED FOR WORK UNDER THIS SECTION OF THE SPECIFICATIONS, BOTH INSIDE AND OUTSIDE OF THE BUILDING, INCLUDING REPAIRING OF FINISHED SURFACES, ALL REQUIRED SHORING, BRACING, PUMPING, AND ALL PROTECTION FOR SAFETY OF PERSONS AND PROPERTY, LOCAL OR STATE SAFETY CODES SHALL BE FOLLOWED, B. IN ADDITION, THE ELECTRICAL CONTRACTOR SHALL CHECK THE ELEVATIONS OF THE UTILITIES ENTERING AND LEAVING THE BUILDING. IF SUCH ELEVATIONS REQUIRE EXCAVATIONS LOWER THAN THE FOOTING LEVELS, THE ARCHITECT/ELECTRICAL ENGINEER SHALL BE NOTIFIED OF SUCH CONDITIONS BEFORE EXCAVATIONS COMMENCE. ELECTRICAL CONTRACTOR SHALL MAKE EXCAVATIONS AT THE MINIMUM REQUIRED DEPTHS IN ORDER NOT TO UNDERCUT THE FOOTINGS. CONFORM TO THE REQUIREMENTS OF THE STATE OF FLORIDA "TRENCH SAFETY ACT". FILLING, BACKFILLING AND COMPACTION SHALL BE AS SPECIFIED IN OTHER AREAS OF THE CONTRACT DOCUMENTS AND SPECIFICATIONS. 3.04 MATERIAL AND WORKMANSHIP A. ALL MATERIALS AND APPARATUS REQUIRED FOR ELECTRICAL WORK, EXCEPT AS SPECIFICALLY NOTED OTHERWISE, SHALL BE NEW, OF FIRST CLASS QUALITY, AND SHALL BE FURNISHED, DELIVERED, ERECTED, CONNECTED AND FINISHED IN EVERY DETAIL AND SHALL BE SO SELECTED AND ARRANGED AS TO FIT PROPERLY INTO THE BUILDING SPACES. WHERE NO SPECIFIC KIND OR QUALITY OF MATERIAL IS GIVEN, A FIRST CLASS STANDARD ARTICLE, AS APPROVED BY THE ELECTRICAL ENGINEER, SHALL BE PROVIDED. B. ELECTRICAL CONTRACTOR SHALL PROCURE THE SERVICES OF AN EXPERIENCED SUPERINTENDENT, WHO SHALL BE CONSTANTLY IN CHARGE OF THE INSTALLATION OF THE WORK, TOGETHER WITH ALL SKILLED WORK PERSONNEL, FITTERS, METAL WORKERS, WELDERS, HELPERS, AND LABOR REQUIRED TO UNLOAD, TRANSFER, ERECT, CONNECT, ADJUST, START, OPERATE AND TEST EACH SYSTEM. C. ALL EQUIPMENT AND MATERIALS SHALL BE INSTALLED IN ACCORDANCE WITH THE RECOMMENDATIONS OF THE MANUFACTURER. THIS INCLUDES THE PERFORMANCE OF ALL TESTS RECOMMENDED BY THE MANUFACTURER. 3.05 CUTTING AND PATCHING A. ELECTRICAL CONTRACTOR SHALL PROVIDE ALL CUTTING AND PATCHING NECESSARY TO INSTALL ELECTRICAL WORK. PATCHING SHALL MATCH ADJACENT SURFACES AND SHALL MEET THE APPROVAL OF THE ARCHITECT AND OWNER. B. NO STRUCTURAL MEMBERS SHALL BE CUT OR MODIFIED IN ANY WAY WITHOUT THE WRITTEN APPROVAL OF THE STRUCTURAL ENGINEER. ANY MODIFICATION SHALL BE DONE IN A MANNER APPROVED BY THE STRUCTURAL ENGINEER. 3.06 SLEEVES AND PLATES A. ELECTRICAL CONTRACTOR SHALL PROVIDE AND LOCATE ALL SLEEVES REQUIRED FOR ELECTRICAL WORK BEFORE THE FLOORS, WALLS AND CEILINGS ARE CONSTRUCTED, OR SHALL BE RESPONSIBLE FOR THE COST OF CUTTING AND PATCHING WHERE SLEEVES WERE NOT INSTALLED, OR WHERE INCORRECTLY LOCATED. ELECTRICAL CONTRACTOR SHALL PROVIDE ALL DRILLING REQUIRED FOR THE INSTALLATION OF HIS HANGERS. SLEEVES SHALL BE PROVIDED FOR ALL CONDUIT PASSING THROUGH CONCRETE FLOOR SLABS ABOVE GRADE AND CONCRETE, MASONRY, TILE AND GYPSUM WALL CONSTRUCTION. B. CONDUIT THROUGH FLOORS AND WALLS SHALL UTILIZE A U.L. APPROVED FIRE RATED PENETRATION SYSTEM. WHERE SLEEVES ARE PLACED IN EXTERIOR WALLS BELOW GRADE, THE SPACE BETWEEN THE CONDUIT AND THE SLEEVES SHALL BE SEALED WATERTIGHT. C. WHERE CONDUIT MOTION DUE TO EXPANSION AND CONTRACTION WILL OCCUR, PROVIDE SLEEVES OF SUFFICIENT DIAMETER TO PERMIT FREE MOVEMENT OF THE CONDUIT. CHECK FLOOR AND WALL CONSTRUCTION FINISHES TO DETERMINE PROPER LENGTH OF SLEEVES FOR VARIOUS LOCATIONS. PROVIDE ACTUAL LENGTHS TO SUIT THE FOLLOWING: 1. TERMINATE SLEEVES FLUSH WITH WALLS, PARTITIONS AND CEILING. 2. IN AREAS WHERE CONDUIT IS CONCEALED, AS IN CHASES, TERMINATE SLEEVES 1"ABOVE FLOOR. 3. IN AREAS WHERE CONDUIT IS EXPOSED, EXTEND SLEEVES 2" ABOVE FINISHED FLOOR. 4. SLEEVES SHALL BE CONSTRUCTED OF SCHEDULE 40 STEEL PIPE. D. FASTEN SLEEVES SECURELY IN FLOORS AND WALLS SO THEY WILL NOT BECOME DISPLACED WHEN CONCRETE IS POURED OR WHEN OTHER CONSTRUCTION IS BUILT AROUND THEM. TAKE PRECAUTIONS TO PREVENT CONCRETE, PLASTER OR OTHER MATERIALS FROM BEING FORCED INTO THE SPACE BETWEEN PIPE AND SLEEVE DURING CONSTRUCTION. 3.07 PENETRATIONS A. ALL PENETRATIONS THROUGH FIRE RATED FLOORS, WALLS AND CEILINGS SHALL BE PROVIDED WITH A U.L. APPROVED FIRE STOP METHOD IN ACCORDANCE WITH THE FLORIDA FIRE PREVENTION CODE 7TH EDITION (EFFECTIVE 12/31/2020). 3.08 TESTING AND PROJECT CLOSE-OUT A. TESTING: FINAL TESTS SHALL BE MADE AFTER WORK HAS BEEN COMPLETED. PROVIDE COPY OF FINAL TEST TO GENERAL CONTRACTOR/ ARCHITECT/ ELECTRICAL ENGINEER. WHEN REQUESTED, THE ELECTRICAL CONTRACTOR SHALL CONDUCT REQUIRED OPERATING TEST(S) IN THE PRESENCE OF THE ARCHITECT/ELECTRICAL ENGINEER AND OTHER AUTHORIZED PERSONS. B. TESTS SHALL DEMONSTRATE THAT THE SYSTEM FUNCTIONS PROPERLY THROUGHOUT, THAT IT IS FREE FROM GROUNDS AND SHORTS, AND THAT ALL REQUIREMENTS HEREIN HAVE BEEN COMPLIED WITH. ELECTRICAL CONTRACTOR SHALL PROVIDE ALL NECESSARY INSTRUMENTS AND PERSONNEL FOR TESTS AND THE OWNER WILL SUPPLY THE CURRENT. TESTS SHALL BE AS PRESCRIBED BY THE AUTHORITY HAVING JURISDICTION AND ENGINEER AND SHALL INCLUDE MEGGER TESTS IN ACCORDANCE WITH N.E.C. RECOMMENDATIONS. C. CONTROLS FOR AUTOMATIC LIGHTING SYSTEMS SHALL COMPLY WITH FBC-ENERGY C408.3. PRIOR TO PASSING FINAL INSPECTION, THE ELECTRICAL CONTRACTOR SHALL PROVIDE EVIDENCE TO THE ENGINEER THAT THE LIGHTING CONTROLS SYSTEMS HAVE BEEN TESTED TO ENSURE THAT CONTROL HARDWARE AND SOFTWARE ARE CALIBRATED, ADJUSTED, PROGRAMMED AND IN PROPER WORKING CONDITION IN ACCORDANCE WITH THE CONSTRUCTION DOCUMENTS AND MANUFACTURER'S INSTRUCTIONS. FUNCTIONAL TESTING SHALL BE IN ACCORDANCE WITH FBC-ENERGY C408.3.1.1 AND C408.3.1.2 FOR THE APPLICABLE CONTROL TYPE. 3.09 FINAL ACCEPTANCE A. AFTER TESTING, A FINAL INSPECTION SHALL BE MADE BY THE GENERAL CONTRACTOR / ARCHITECT/ ELECTRICAL ENGINEER AND OTHER AUTHORIZED PERSONS WITH THE ELECTRICAL CONTRACTOR. THE INSPECTION SHALL INCLUDE, BUT NOT BE LIMITED TO, CHECK ALL PANELS ARE COMPLETE WITH NAMEPLATES AND CIRCUIT DIRECTORIES, ALL LIGHTING FIXTURES ARE OPERATING, PROPERLY CLEANED AND LAMPED, AND THAT ALL WORK HAS BEEN PERFORMED IN PROFESSIONAL MANNER. B. FINAL ACCEPTANCE OF THE PROJECT SHALL NOT PREJUDICE THE OWNER'S RIGHT TO REQUIRE REPLACEMENT AND/OR REPAIR OF ANY DEFECTIVE WORK OR MATERIALS. 3.10 WARRANTY A. ALL PARTS, MATERIALS, EQUIPMENT AND LABOR FURNISHED UNDER THIS SECTION OF THE SPECIFICATIONS SHALL BEAR A ONE (1) YEAR, NO COST TO THE OWNER, WARRANTY FROM THE DATE OF FINAL ACCEPTANCE. ELECTRICAL CONTRACTOR SHALL PROVIDE ALL OF THE ABOVE WARRANTY REQUIREMENTS IN A WRITTEN STATEMENT ALONG WITH EQUIPMENT MANUFACTURER'S WARRANTIES. 3.11 RECORD DRAWINGS A. ELECTRICAL CONTRACTOR SHALL KEEP ACCURATE RECORDS OF ACTUAL CONDITIONS DEVICE INCLUDING LOCATIONS I IC AND CONDUIT RUNS WHERE DIFFERENT FROM THE CONTRACT DOCUMENTS. ELECTRICAL CONTRACTOR SHALL PROVIDE OWNER WITH A REPRODUCIBLE SET OF "AS BUILT" PLANS SHOWING THE COMPLETE ELECTRICAL SYSTEMS AS INSTALLED (AS BUILT DRAWINGS). THE SCALE ON THESE AS BUILT DRAWINGS SHALL BE NO SMALLER THAN THE SCALE USED ON THE ORIGINAL PLANS. END OF DIVISION 16 - C&K ARCHITECTS I INTERIORS architecture -interior design .client services AAC001629 4221 WEST BOY SCOUT BLVD., SUITE 150 TAMPA, FL 33607-5743 813.884.2000 280 WEST CENTRAL AVE. WINTER HAVEN, FL33880-2957 863.577.2054 3. FE/ \Q � °\CENSF•.;e, .� �-, Q 5083':7 -0> Of 1./1 21;: w O ° STATE OF . w X\ °°. :, F S°°s.„R, G 'ON AL•E z 0 N >� mo i t J U_ N J J >_ ! a N N Z OI I- O V M f W V LU 0- C , =O LU O .j N a V_ Q 1 De Cm I _= i V en W ` .j W 0 m M a - LO ISSUED FOR: PERMIT PROJECT NUMBER 21020 DATE i 5.5.21 DRAWING NUMBER i C . L 2 EOc C C i �� 5 C 5 - - ir II-� I IIII I 1 I _ ..11 I I 1111 I II ir. ld _I: i 1'I .i .ail. �.I.. RIMARY DAYLIGHT ZONE. el EX IX 1 31 31 #31 #31 1/EM J Al ® Al Al/E I F F #3) SP Al #31 Al A #31 1 #31 F 00 DINT LSP� Ap F-7 :- SPA I Al #31 A1/EM #31 Al #31 I C #33 #33 33 #33 #3C C CO C C C C C C0 0 C Cr'-C CO3 0#33 C SWITCH FOR 0#33 r7 Id CEILING FANS. e Al/EM C d Al #31 1M #31 d1 F 0#33 I/ \ I �� ! glF�� I I C #31 C 0#33 zi0#33 tAI�EM C EX 0#33 #3 C #31 #31 #31 #31 Al B/EM B/EM FS B #31 CB) #31 LIGHTING LEGEND #31 #XX = CIRCUIT NUMBER ON PANELBOARD "BK" Al -A LOWERCASE LETTER = SWITCH DESIGNATION c E 7i EX Al /EM l 102 (BIEM #31 B #31 Al /EM NE 104 #3 C #31 o Al #31 B F-1 x 0 i c #31 #31 ,I��EM � LE �SP� EX F FS FS N ELECTRICAL PROPOSED LIGHTING PLAN 0 2' 4' 8' GS JOB #: 5S31 .21 .00 SCALE: 1/4" = 1'-0" GLOBAL Srm%K4C11 1r.7- . MEPF ENGINEERING INF❑@GLOBAL-SANCHEZ. COM CA#: 6237 81 6 MANATEE AVE. E, SUITE 1 8 BRADENTON, FL 34208 PHONE: 941 -758-2551 3825 HENDERSON BLVD., SUITE 1 ❑3 TAMPA, FL 33629 PHONE: B 1 3-28 1 -❑❑❑ 1 ICI #3O OFF C/ Ew ry ry N a A m co N 0 N 0 v C �n w F Q C&K ARCHITECTS � INTERIORS architecture• interior design• client services AAC001629 4221 WEST BOY SCOUT BLVD., SUITE 150 TAMPA, FL 33607-5743 813.884.2000 280 WEST CENTRAL AVE. WINTER HAVEN, FL33880-2957 863.577.2054 \Q J. FF,� � �\CENSF•.;F� ��• Q o 65083 \.-y .5 021;: W � °.• STATE: OF <v F`sS; PROVIDE 2"X4" JUNCTION BOX AND PULL STRING NEXT TO TV OUTLETS. COORDINATE EXACT HEIGHT & LOCATION WITH ARCHITECT. 40 41 2 POWER KEYED NOTES OPROVIDE 2"X4" JUNCTION BOX AND PULL STRING NEXT TO TV OUTLETS. COORDINATE EXACT LOCATION WITH ARCHITECT. ORECEPTACLES FOR FRONT WINDOW SIGNAGE. COORDINATE EXACT LOCATION WITH ARCHITECT/CLIENT. RECEPTACLES SHALL BE MOUNTED IN SOFFIT ABOVE STOREFRONT (TYPICAL OF 2). OMOUNTED IN SOFFIT FOR MENU BOARDS. COORDINATE INSTALLATION REQUIREMENTS WITH EQUIPMENT PROVIDER PRIOR TO ROUGH -IN. OPROVIDE 1-1/4" CONDUIT BETWEEN POINT OF SALE TO REMOTE PRINTER FOR CAT 6 CABLE. ORECEPTACLE FOR CO DETECTOR, COORDINATE FINAL LOCATION AND INSTALLATION REQUIREMENTS WITH EQUIPMENT PROVIDER PRIOR TO ROUGH -IN. OJUNCTION BOX FOR GAS APPLIANCES, COORDINATE FINAL LOCATION WITH OWNER PRIOR TO ROUGH -IN. O JUNCTION BOX FOR HOOD LIGHTING. BK-21 AB27 GFI L--_J BK-29 GFI GFI L BK-1 J TT 7 B K-21 F_ 1 GF l BK 8 J I I I I I I fJUNCTION BOXES ON A TIMER FOR TENANT SIGN. COORDINATE FINAL LOCATION WITH OWNERS CONSTRUCTION REPRESENTATIVE. T I I T I BK-28 I- - -1 L ROVIDE 2"X4" JUNCTION BOX AND PULL STRING NEXT TO TV OUTLETS. BK-21 110 COORDINATE EXACT HEIGHT & LOCATION WITH ARCHITECT. - _F=711 -I� _ GFI III I GFI) II GFI GFI 1 GFI I GFI L fi �'Ffi BK-10 �K-�- K-16 BK-14 BK-18 BK-26 - 1BK-11 - ------ILL -_-- IL - - -- 3 3 = ---4- - - - F- - -I BK-2 BK-4 3 F L .r _ SERVICE GFI 33 ( L II II II III BK-20 III rm 4K717 AIh- ;13 bK_15 J BK-3 1,BK-P 34 22 BK-23 OFFICE 103 I BK-23 NOMENS la4 �n BK-23 �J +40" GFI O O GFI +40" ODBK-23 MENS 105 NEW 40OAl DISCONNECT. NEMA 3R. NEW 400A METER, COORDINATE FINAL LOCATION. T LINE L01 r----------- 1 -15BK-2)F - - IM I�T�IGFI IlO T--T I ( I I I I I •7 BK- NEW PANEL „BK"; 208/120/3PH 400A I I I I 1 I I I I BK-6 14 I I J I 1 I- - _j L_ - _j MOUNTED F -1 (- - ABOVE I I WALK IN BOX I I �K-51,53) I I I I 1 I !F 7I 11 1 T TO EXISTING TRANSFORMER SCALE: 1/4" = 1'-0" i F_ J I I I I I GFI BK-19 I GFII K-25 GFI GFI BK-25 COMMERCIAL CONDENSING, OUTDOOR, TANKLESS WATER HEATER BY RINNAI WALL MOUNTED. (MODEL CU199EN, 199 MBH INPUT, 120 VOLTS SINGLE PHASE) 1. GARBAGE/RECYCLING CENTER 2. ICE CUBER 3. MENU BOARDS PROVIDED AND INSTALLED BY G.C. SAMSUNG 50" LED UN50NU. 4. WALK-IN COOLER 8' X 10' 5. POINT -OF -USE WATER HEATER PROVIDED AND INSTALLED 30 BY G.C. 6. PREP SINK 7. POS PROVIDED AND INSTALLED BY TENANT. 8. SANDWICH/SALAD PREP FRIDGE 9. 3 PAN HOT SERVING COUNTER 9A. CUTTING BOARD (NOT SHOWN). 10. HEAT LAMP 11. FOOD TOPPING WARMER 12. SANDWICH PANINI GRILL 13. REACH -IN FREEZER 14. CAN OPENER (NOT SHOWN) 15. REFRIGERATED EQUIP. STAND 16. SS WORK TABLE 36" X 30" 17. SS WORK TABLE 48" X 30" 18. SS WORK TABLE 60" X 30" 19. SS WORK TABLE 72" X 30" 20. SS SHELVING 36" X 12" 21. SS SHELVING 60" X 12" 22. RICE COOKER 23. 3-COMP.SINK 24. GAS GRIDDLE 48" 25. GAS GRIDDLE 24" 26. GAS FRYER 27. HOT PLATE (NOT SHOWN) 46 27A. GAS HOSE KIT 27B. SS STAND 24" X 30" 28. HAND SINK 29, SOAP DISPENSER PROVIDED AND INSTALLED BY G.C. ECOLAB NEXA - SURFACE MTD. 30. REACH -IN FREEZER 31. SS SHELF 12" X 36" 32. 14' EXHAUST AND SUPPRESSION HOOD PROVIDED AND INSTALLED BY G.C. 33. HOOD UTILITY CABINET PROVIDED AND INSTALLED BY G.C. 34, APW FOOD WARMER 35. METRO SHELVING 48' X 24 36. METRO SHELVING 36" X 24" 37. METRO SHELVING 60" X 24" 37A. SHELF WITH METAL FRAME 37B. SHELF WITH METAL FRAME 38. GREASE TRAP PROVIDED AND INSTALLED BY G.C. 39. MOP SINK AND DURAGUARD WALL GUARDS 67.2424 PROVIDED AND INSTALLED BY G.C. 40. PEPSI COOLER BY TENANT VENDOR. 41. PEPSI DISPENSER BY TENANT VENDOR. 42. TV PROVIDED AND INSTALLED BY G.C. SAMSUNG 75" NU6900. 43. SNEEZE GUARD PROVIDED AND INSTALLED BY G.C. DK HARDWARE PP65 LEBS. 44. WALL MOUNTED SHELVING (ABOVE) 45. BAG IN BOX SYSTEM PROVIDED BY TENANT, INSTALLED BY G.C. 46. REACH IN FREEZER 47, PAPER TOWEL HOLDER PROVIDED AND INSTALLED BY G.C. GP PRO VISTA DISPENSER #370052 48. SS WORK TABLE 30" X 24" 49. WIRE SHELVING 36" X 18" J A. CUSTOM MILLWORK BY FOOD SERVICE VENDOR B. BANQUETTE SEATING PROVIDED AND INSTALLED BY G.C. C. TABLE AND CHAIRS BY TENANT 9 D. ADA SEATING C&K ARCHITECTS I INTERIORS architecture. interior design. client services AAC001629 4221 WEST BOY SCOUT BLVD., SUITE 150 TAMPA, FL 33607-5743 813.884.2000 280 WEST CENTRAL AVE. WINTER HAVEN, FL33880-2957 863.577.2054 �P 3. FF/ Q 65082'%-y �; 5/1 2021 W O STATE OF k/ c0-` cam' F`ss't OR /ONA1. Z 0 s mQ 0 0 z J N Z J_ a W N Lu Cn 0 0 �_ CL De W Ca C Qx! CL 0 0 LLJ N0 rx CL Q J m V m Vm W __j Q J 0 W LO "' a LO ISSUED FOR: PERMIT PROJECT NUMBER 21020 DATE 5.5.21 DRAWING NUMBER E5m I I Ll El 1:1 El - Ll E] 11 F-1 [7 L [_1 F1 F1 F-1 F-1 00 DINNG ARf 0 BK-42,44,46 NE10A 3R D-3 RTU NEMA3R 0 1 KSF-1 BK-30,32,34 ON ROOF D-1 wP GF1 F- - — -- — — — — — — — — BK-50 — — — — — — — — — — — — — — — — PROVIDE GFCI RECEPTACLE WITHIN 25'OF ALL ROOFTOP MECHANICAL EQUIPMENT PER NEC 210.63. COVER SHALL BE WEATHERPROOF -IN -USE TYPE. COORDINATE LOCATIONS WITH MECHANICAL CONTRACTOR. 18"0 EXHAUST BK-37,39,41 18"0 EXHAUST GREASE DUCT UP D-4 GREASE DUCT UP TO KEF-1 TO KEF-2 '-b7 NEMA3R I NEMA3R BK-43,45,47 D-5 OFFICE 103 KITCHEN 102 BK-36138140 --,I D-2 NEMA 3R + NO TENS 104 ] F q RTU 2 E LT uo MENS 105 GS JOB #: S831.21.00 GLOBAL SrwK4CL"Zlp ria. '4C MEPF ENGINEERING INFO@GLOBAL—SANr—F-iEZ.r—Om r-A#: 6237 B 1 6 MANATEE AVE. E, SUITE 113 BRADENTON, FL 3420B PHONE: 941-758-2551 31325 HENr)ERSON BLVD., SUITE 103 TAMPA, FL 33629 PHONE: B 1 3-2B 1 -000 1 IrMI: . . . . . . . . . . . . . . . .... sus C&K ARCHITECTS I INTERIORS architecture• interior design• client services AAC001629 4221 WEST BOY SCOUT BLVD., SUITE 150 TAMPA, FL 33607-5743 813.884.2000 280 WEST CENTRAL AVE. WINTER HAVEN, FL 33880-2957 863.577.2054 FE, E 4z 6508 T /2021 STATE OF AN % F••'••'c�CR\�P°'G�� /ONAL 0 ti 7F >4 'm LL. z Lu 3: 0 Lj- 0 a- U) 0 0 m Lu NO �e Ca ca LLJ Lu (D Cl) Lf) 01 LO ISSUED FOR: PERMIT PROJECT NUMBER 21020 DATE 5.5.21 DRAWING NUMBER E5m2 5 ESTIMATED VOLTAGE DROP (208V) COPPER SERVICE FEEDER CONDUCTORS CONDUCTOR SIZE 600 kCMIL, CU RESISTANCE (0/1000') 0.028 NUMBER OF PARALLEL RUNS 1 CONDUCTOR LENGTH 50' APPROXIMATE LOAD 400 A PHASE 3PH ESTIMATED VOLTAGE DROP 0.97 V VOLTAGE 1 208 V VOLTAGE DROP 0.47 % VOLTAGE DROP BELOW 3% PER NEC 215.2 AND FBC-E, 7TH ED. C405.5.3 PANELBOARDe 'MAIN' (COPPER) ESTIMATED FAULT CURRENT CONDUCTOR SIZE 600 kCMIL, CU CONDUCTOR LENGTH 50' CONDUCTOR "C" 28,033 NUMBER OF PARALLEL RUNS 1 TOTAL CONDUCTOR "C" 28,033 ESTIMATED TRANSFORMER SCA 65,000 A VOLTAGE 208 V FAULT CURRENT 33,07 2A FAULT CURRENT SCA/(1+[(1.73*L*SCA)/(C*V)]) 33,072A SHORT CIRCUIT AMPS i ESTIMATED AT PANEL NOTE: FAULT CURRENT CALCULATION IS BASED ON ESTIMATED UTILITY TRANSFORMER AVAILABLE FAULT CURRENT AND LOCATIONS OF EQUIPMENT SHOWN ON THE PLANS. ELECTRICAL CONTRACTOR SHALL CONFIRM ABOVE INFORMATION IS CORRECT PRIOR TO ORDERING EQUIPMENT. ELECTRICAL CONTRACTOR SHALL PROVIDE EQUIPMENT WITH SUITABLE INTERRUPT RATINGS. ANY DISCREPANCIES SHALL BE REPORTED TO THE ENGINEER. ESTIMATED VOLTAGE DROP (208V) COPPER SERVICE FEEDER CONDUCTORS CONDUCTOR SIZE 600 kCMIL, CU RESISTANCE (0/1000') 0.028 NUMBER OF PARALLEL RUNS 1 CONDUCTOR LENGTH 10, APPROXIMATE LOAD 400 A PHASE 3PH ESTIMATED VOLTAGE DROP 0.19 V VOLTAGE 208 V VOLTAGE DROP 0.09 % VOLTAGE DROP BELOW 3% PER NEC 215.2 AND FBC-E, 7TH ED, C405.5.3 PANELBOARDe 'BK' (COPPER) ESTIMATED FAULT CURRENT CONDUCTOR SIZE 600 kCMIL, CU CONDUCTOR LENGTH 10, CONDUCTOR "C" 28,033 NUMBER OF PARALLEL RUNS 1 TOTAL CONDUCTOR "C" 28,033 ESTIMATED TRANSFORMER SCA 33,072 A VOLTAGE 208 V FAULT CURRENT 30,114 A FAULT CURRENT SCA/(1+[(1.73*L*SCA)/(C*V)]) 30,114A SHORT CIRCUIT AMPS ESTIMATED AT PANEL NOTE: FAULT CURRENT CALCULATION IS BASED ON ESTIMATED UTILITY TRANSFORMER AVAILABLE FAULT CURRENT AND LOCATIONS OF EQUIPMENT SHOWN ON THE PLANS, ELECTRICAL CONTRACTOR SHALL CONFIRM ABOVE INFORMATION IS CORRECT PRIOR TO ORDERING EQUIPMENT. ELECTRICAL CONTRACTOR SHALL PROVIDE EQUIPMENT WITH SUITABLE INTERRUPT RATINGS. ANY DISCREPANCIES SHALL BE REPORTED TO THE ENGINEER. 400A NEW PANEL "BK" 208/120V/3PH NEMA 1 400A DISCONNECT 208/12OV/3PH NEMA 3R D-6 PANELBOARDm 'BK' ELECTRICAL SERVICE CALCULATION LOAD CONNECTED DEMAND LIGHTING 1,488 1,860 RECEPTACLES 2,880 2,880 GAS WATER HEATER 180 180 CEILING FANS 700 700 SIGN 1,200 1,500 POS (2) 1,000 1,000 RTU-1 16,212 16,212 RTU-2 24,858 24,858 KSF-1 2,088 2,088 KEF-1 900 900 KEF-2 900 900 #2 - ICE CUBE MAKER 1,086 1,086 #22 - RICE COOKER (4) 7,200 4,680 #30 - SALAD REF. 276 179 #34 - FOOD WARMER (3) 3,600 2,340 #46 - REACH IN FREEZER 1,020 663 #40 - PEPSI COOLER 1,000 650 #41 - DRINK DISP. 1,000 1,000 #3 - MENU BOARD (2) 360 360 #4 - WALK IN COOLER 120 78 #8 - SANDWICH REF. 648 421 #9 - HOT FOOD TABLE 2,100 1,365 #10 - FRENCH FRY WARMER 1,120 728 #11 - FOOD TOPPING WARMER 504 328 #12 - PANINI GRILL 1,800 1,170 #13 - REACH IN FREEZER 780 507 #15 - REF. EQUIP. STAND 276 179 COOLER CAPSULE PACK 2,000 2,000 - 0 0 TOTAL 77,296 70,813 197 AMP DEMAND 400A SERVICE @ 208V, 3-PHASE PROVIDED + .65 DEMAND FACTOR PER NEC 220.56 RISER KEYED (VOTES ONEW 400 AMP SERVICE FEEDER: (1) 3-1/2" CONDUIT WITH (4) 600KCM CU. ONEW 400 AMP SERVICE FEEDER: (1) 3-1/2" CONDUIT WITH (4) 600KCM CU AND (1) #3 AWG CU E.G. ONEW #1/0 CU GROUNDING ELECTRODE CONDUCTOR IN 1" CONDUIT. BOND TO METAL UNDERGROUND WATER PIPE, BUILDING STEEL, ETC. PER NEC 250.50. O#6 AWG COPPER TO (3) NEW 5/8"X1 O' COPPER GROUND RODS SPACED 10' APART. ONEW SURGE PROTECTIVE DEVICE. MINIMUM RATING OF 100KA PER PHASE SURGE CURRENT RATING. PQ PROTECTION PQC100, OR EQUIVALENT. RISER LEGEND EXISTING TO REMAIN NEW O NEW 400A METER ENCLOSURE ELECTRICAL RISER DIAGRAMS SCALE: NOT TO SCALE EXISTING UTILITY TRANSFORMER WITH CT CABINET 1 PANELBOARD DESIGNATION 'BK' VOLTAGE: 208/120V 30 4W MAINS RATING: 400 AMPS MAIN CB TRIP RATING: 400 AMPS SURFACE MCB FLUSH 0 MLO COPPER BUS INTERRUPTING RATING: 65000 AIC ENCLOSURE:NEMA1 SERVES CB SIZE LOAD VA CKT A B C CKT LOAD VA CB SIZE SERVES #2 - ICE CUBE MAKER 20 1086 1 2 180 20 #3 - MENU BOARD RECEPT, #22 - RICE COOKER 20 1800 3 4p 4 180 20 #3 - MENU BOARD RECEPT. #22 - RICE COOKER 20 1800 5 6 120 20 #4 - WALK IN COOLER #22 - RICE COOKER 20 1800 7 40 8 500 20 #7 - POS #22 - RICE COOKER 20 1800 9 411 1 10 648 20 #8 - SANDWICH REF. #30 - SALAD REF. 20 276 11 140 12 2100 25 #9 - HOT FOOD TABLE #34 - FOOD WARMER 20 1200 13 4 1 14 1120 20 #10 -FRENCH FRY WARMER #34 - FOOD WARMER 20 1200 15 16 504 20 #11 - FOOD TOPPING WARMER #34 - FOOD WARMER 20 1200 17 1 0 18 1800 20 #12 - PANINI GRILL #46 - REACH IN FREEZER 20 1020 19 4 0 20 780 20 #13 -REACH IN FREEZER DINING AREA RECEPT. 20 1080 21 41 22 276 20 #15 - REF. EQUIP. STAND B.O.H. RECEPTACLES 20 1080 23 1 24 1 SHUNT TRIP KITCHEN RECEPT, 20 540 25 ql 1 11 26 500 20 POS #40 - PEPSI COOLER 20 1000 27 28 1200 20 SIGN #41 -DRINK DISPENSER 20 1000 29 1 30 5404 45 RTU-1 LIGHTING 20 1194 31 4 1 32 5404 LIGHTING C3 20 294 33 41 34 5404 CEILING FANS 20 700 35 40 36 8286 70 RTU-2 KEF-1 20 300 37 11 38 8286 300 39 4PI 11 40 8286 300 41 42 696 20 KSF-1 KEF-2 20 300 43 40 44 696 300 45 41 46 696 300 47 48 SHUNT TRIP GAS WATER HEATER 20 180 49 4 0 1 50 180 20 ROOF GFI COOLER CAPSULE PACK 20 1000 51 41 1 52 0 20 SPARE 1000 53 0 20 SPARE SPACE 20 0 54 r60 0 30 SPD SPACE 20 0 57 0 SPACE 20 0 59;1 0 * COORDINATE REQUIREMENTS WITH EQUIPMENT PROVIDER. L PROVIDE LOCKABLE OFF PROVISION PER NEC 422.31. ELECTRICAL SCHEDULES SCALE: NOT TO SCALE C&K ARCHITECTS I INTERIORS architecture • interior design • client services AAC001629 4221 WEST BOY SCOUT BLVD., SUITE 150 TAMPA, FL 33607-5743 813.884.2000 280 WEST CENTRAL AVE. WINTER HAVEN, FL 33880-2957 863.577.2054 ° OCE �N, a 5083`�7 4/2021 W '., STATE OF ;'44 Fss� G o N A Z 0 N lC K mQ 0 0 z LL N J_ s ix x a W N W J O W Q/ Z U) V J =0 Q W N V r_ 0�e m V 00 W � J m W J CD J J rQ V M 01 ISSUED FOR: PERMIT PROJECT NUMBER 21020 DATE 5.5.21 DRAWING NUMBER E 7 11 -- -- -------- AS REQUIRED PER ZONE FOR CONTROL OF 0-10V LOADS r---------------------------------------� I ZONE X SWITCHED POWER (8A MAX) I I I I ® I 0-10V DIM (60 mA MAX) RMJS-8T-DV-B POWPAK DIMMING MODULE 120/277V-, 50/60 Hz W/ 0-10 V CONTROL DIMENSIONS: 3.42"(H) X 2.82"(W) X 1.25"(D) I (87mm X 72mm X 32mm) I LOCATE ABOVE ACCESSIBLE CEILING I I IL---------------------------------------J TYPICAL QS TIMECLOCK AS REQUIRED ---------------- I I I I I OQ I I QSGR-TC-3S-WH-CPN5825 I QS TIMECLOCK w/ 3 SHADE COLUMNS (4 GANG US BACKBOX BY OTHERS) LOCATE IN MAIN ELECTRICAL CLOSET I I L------------------------------t TYPICAL OF RESTROOMS AS REQUIRED r--------------------------------- I I I I i I I I I I I (1) PJ2-2BRL-GWH-XXX 434 MHZ PICO WIRELESS 2 BUTTON CONTROL WITH RAISE/LOWER SHOWN WITH CW-2-WH CLARO WALLPLATE *SEE SPECIFICATION SHEET FOR DIMENSIONS, ENGRAVING OPTIONS, & MOUNTING INSTRUCTIONS I I REFER TO FLOOR PLAN FOR QUANTITY AND LOCATIONS -------------------------------- I I AS REQUIRED FOR CONTROL OF NORMAL 0-10V & NON -DIM LOADS ZONES r------------------------------------- I I I I ZONE X 120V/277V E1`0 120V/277V 120V/277V 120V/277V E3-- 120/277V I TO QUANTUM HkJB&Q 0-10V I I ZONE X 0-10V I ® I ZONE X 0-10V I ZONE X 0-10V I ESN# To QS Devices (Up to 14 PDUs) QSN-4T16-S ENERGI SAVR NODE QS (ESN) WITH (4) SWITCHED OUTPUTS, (4) 0-10V CHANNELS, AND I I (1) QS COMMUNICATIONS LINK DIMENSIONS: 13.25"[336,7mm] (H) X 9.25"[235mm] (W) X 3.16"[80,3mm] (D) LOCATE ABOVE ACCESSIBLE CEILING I I L------------------------------------J LUTRON PROVIDED JACK OR (FOR US INSTALLATIONS ONLY) OQ ETHERNET PORT BY OTHERS C-ESN-SETUP a <<< (WIRELESS ROUTER QSE-CI-AP-D NT-05E/B-NFB-WH-E-CPW1338 ENERGI SAVR NODE LUTRON LIGHTING SYSTEM APPLE®IPOD TOUCH PROGRAMMING INTERFACE DEDICATED PROGRAMMING PORT OR IPHONE"MOBILE DIMENSIONS: (1 GANG US BACKBOX BY OTHERS) DIGITAL DEVICE 3.5"[89mm] (H) X 2.1"[53mm] (Vv) — — — — — — — — X 2.4"[61 mm] (D) LOCATION TBD TYPICAL OF OPEN AREA AND KITCHEN AS I REQUIRED r-----------------------------� I I I I I I I LRF2-VCR2B-P-WH 434MHZ WIRELESS I I OCCUPANCY SENSOR i I 3.57"[90,7mm] (DIA) X 1.13"[28,7mm] (D) MAX 10 PER QSM *DEVICE IS SURFACE -MOUNTED AND BATTERY POWERED, DOES NOT i I REQUIRE POWER FEED I I I I (OPTION:WITH L-CRMK-WH i I RECESS MOUNT KIT FOR I NON-METALLIC CEILINGS) REFER TO FLOOR PLAN FOR QUANTITY AND LOCATIONS L----------------------------- J TYPICAL OF SALE AREA AND BACK OF HOUSE AS REQUIRED MAX OF 10 PER QSM r---------------------------- I I I I I I I I I I I LRF2-OCR2B-P-WH I i 434MHZ WIRELESS OCCUPANCY/VACANCY SENSOR I 3.57"[90,7mm] (DIA) X 1.13"[28,7mm] (D) I MAX 10 PER QSM I i -DEVICE IS SURFACE -MOUNTED AND BATTERY POWERED, DOES NOT REQUIRE POWER FEED I I I i (OPTION:WITH L-CRMK-WH RECESS MOUNT KIT FOR NON-METALLIC CEILINGS) REFER TO FLOOR PLAN FOR QUANTITY AND LOCATIONS LL---------------------------J AS REQUIRED -------------------- I I I I I I I I QSM# I QQ I I I QSM2-4W C QUANTUM SENSOR MODULE (QSM) WITH (4) UNIVERSAL WIRED INPUTS AND 434MHZ WIRELESS RECEIVER I 60'[18.29m] RADIUS RF COVERAGE (30'[9.14m] THROUGH WALLS) 4.04"[102.6mm] (DIA) X 1.17"[29.7mm] (D) I LOCATION TBD I I I I I I L------------------------------ J AS REQUIRED MAX OF 10 PER QSM ----------------------------i I i-I I I I I I I � I LRF2-DCRB-WH 434MHZ WIRELESS i I DAYLIGHT SENSOR 1.6"[40,6mm] (DIA) X 0.7"[17,8mm] (D) MAX 10 PER QSM *DEVICE IS SURFACE -MOUNTED AND i I BATTERY POWERED, DOES NOT REQUIRE POWER FEED REFER TO FLOOR PLAN FOR i I QUANTITY AND LOCATIONS I I TYPICAL OVERRIDE KEYPAD AS REQUIRED r--------------------------- I I I I I I I I I I I I I LQ m I I I QSWS2-5BRLI-WH 5-BUTTON SCENE SELECT WITH RAISE/LOWER (1 GANG US BACKBOX BY OTHERS) REFER TO FLOOR PLAN FOR QUANTITY AND LOCATIONS L--------------------------J *ALTERNATE DATA -ONLY CABLE: USE APPROVED DATA LINK CABLE (22 AWG [0.5 mm2] TWISTED/SHIELDED) FROM BELDEN (MODEL # 9461). **TOTAL LENGTH OF THE QS LINK MUST NOT EXCEED 2,000 ft (600 m). 0 INPUT POWER (NORMAL -EMERGENCY) ❑ INPUT POWER (NORMAL) 2 #12AWG (4 mm2) O 3 #12AWG (4 1 ® 0-1OV SIGNAL: 2 #18AWG (1.0 mm2) E❑ CAT5E OR BETTER CABLE FOR LUTRON NETWORK TERMINATED WITH RJ45 CONNECTORS (TO BE PROVIDED BY OTHERS). 328 ft (100 m) MAXIMUM RUN. 1-WAY RF COMMUNICATION 2-WAY RF COMMUNICATION 2 #18AWG (1.0 mm2) CONCEPT DRAWING NOTES: CONTROL SYSTEM DRAWING IS PROVIDED FOR CONCEPTUAL PURPOSES ONLY AND IS NOT INTENDED FOR CONSTRUCTION. EXACT EQUIPMENT REQUIREMENTS, INCLUDING LOCATIONS AND QUANTITIES, SHOULD BE VERIFIED IN ACCORDANCE WITH THE MOST UP-TO-DATE LIGHTING/ELECTRICAL REFLECTED CEILING PLANS, LIGHTING FIXTURE SCHEDULES, PANEL SCHEDULES, CONTROL INTENT AND SPECIFICATIONS. SHADE EQUIPMENT SHOULD BE VERIFIED IN ACCORDANCE WITH ARCHITECTURAL PLANS, SPECIFICATIONS AND WINDOW SCHEDULES/DETAILS. WIRING LEGEND: QQ QS CONTROL LINK (SEE WIRE DESCRIPTION BELOW) .Q QS CONTROL LINK (SEE WIRE DESCRIPTION BELOW) (CONNECT WIRES 1, 3 AND 4. DO NOT CONNECT WIRE # 2) QS WIRING AS REQUIRED BY CONTROL LINK LENGTH (REFER TO QS SMART PANEL POWER SUPPLY WIRING GUIDE FOR SHADE WIRING NOTES): TOTAL CONTROL WIRE GAUGE AVAILABLE FROM LUTRON IN ONE LINK LENGTH CABLE: POWER (TERMINALS 1&2): LESS THAN 500ft 1 PAIR 18 AWG (1.0 mm0 GRX-CBL-346S (NON -PLENUM) (152.4 m) OR GRX-PCBL-346S (PLENUM) DATA (TERMINALS 3&4): 1 PAIR 22 AWG (0.5 mm�, TWISTED AND SHIELDED* POWER (TERMINALS 1&2): 500ft (152.4 m) TO 1 PAIR 12 AWG (4.0 mm� GRX-CBL-46L (NON -PLENUM) 2,000ft (610 m)** OR GRX-PCBL-46L (PLENUM) DATA (TERMINALS 3&4): 1 PAIR 22 AWG (0.5 ni TWISTED AND SHIELDED* WIRING NOTES: QS LINK RULES THE FOLLOWING LINK RULES MUST BE OBSERVED FOR PROPER OPERATION: • THIS IS A TOPOLOGY -FREE LINK (T-TAP, HOME -RUN, ETC. IS OK); REFER TO TABLE BELOW FOR WIRE RUN LIMITS. • IF WIRED DIFFERENTLY THAN WHAT IS SHOWN, POWER DRAW UNIT REQUIREMENTS NEED TO BE CONFIRMED; SEE POWER DRAW UNITS (PDUs) SPECIFICATION SHEET INCLUDED IN THIS SUBMITTAL. • MAXIMUM OF 512 OUTPUTS (BALLASTS, SHADES, CONTACT CLOSURES, ETC). • MAXIMUM OF 100 OCCUPANCY SENSORS, 100 DAYLIGHT SENSORS/RADIO SHADOW SENSORS AND 100 KEYPADS. • MAXIMUM OF 100 QS DEVICES (SUCH AS A GRAFIK EYEO QS, SEETOUCHO QS KEYPAD, SMART PANEL POWER SUPPLY [ASPS-Px-10-60], ESN, OR SIVOIAO QS SHADE / DRAPERY DRIVE UNIT). QUANTUM PROCESSOR COUNTS AS 1 DEVICE PER LINK. • MAXIMUM OF 100 ZONES - SUCH AS A SIVOIA QS SHADE / DRAPERY DRIVE UNIT, OR A LIGHTING ZONE ON A GRAFIK EYE QS (DOES NOT APPLY TO QUANTUM SYSTEMS). • THE 10 OUTPUTS ON A QSPS-Px-10-60 CANNOT EXCEED A COMBINED LENGTH OF 2,000 ft (600 m). QUANTUM NETWORK WHEN A LIGHTING MANAGEMENT NETWORK (LMN) IS REQUIRED TO ENABLE COMMUNICATIONS BETWEEN INDIVIDUAL LIGHT MANAGEMENT HUBS (LMH) AND BETWEEN LMH AND THE SYSTEM SERVER/DESKTOP/LAPTOP (Q-MANAGER). THE LMN REQUIRES A DEDICATED LAN OR VLAN. IT IS THE RESPONSIBILITY OF THE NETWORK PROVIDER TO ENSURE THE RELIABILITY AND SECURITY OF THE LMN. CAT5E OR BETTER ETHERNET CABLE TO BE RUN FOR DEDICATED LMN TERMINATED WITH RJ45 CONNECTORS (PROVIDED BY OTHERS). THE NUMBER OF ETHERNET HOPS/SEGMENTS BETWEEN THE SERVER/DESKTOP/LAPTOP (Q-MANAGER) AND ANY LMN NODE SHALL NOT EXCEED 6. TOTAL LENGTH OF ETHERNET CABLE SHALL NOT EXCEED 328 FT (100M) POINT-TO-POINT. IF LONGER RUNS ARE REQUIRED, MULTI -MODE FIBER OPTIC CABLE CAN BE USED INSTEAD WITH APPROPRIATE FIBER OPTIC CONNECTORS (PROVIDED BY OTHERS). CONSULT WITH NETWORK PROVIDER FOR STANDARD ETHERNET AND FIBER OPTIC WIRING RULES FOR DISTANCE AND SEPARATION AS WELL AS FOR PLACEMENT OF SWITCHES, ROUTERS, HUBS, ETC. FOR MORE INFORMATION REGARDING NETWORK EQUIPMENT REQUIREMENTS AND NETWORK CONFIGURATION, PLEASE REFER TO THE QUANTUM LIGHTING MANAGEMENT NETWORK SPECIFICATION SHEET OR CONTACT LUTRON. PANEL LINK RULES THE FOLLOWING LINK RULES MUST BE OBSERVED FOR PROPER OPERATION: • PANELS ARE DAISY -CHAINED ON ONE OF THE CONFIGURABLE LINKS PER LUTRON'S DRAWING, HOWEVER THEY DO NOT HAVE TO BE IN THE ORDER SHOWN. • DO NOT HOME -RUN OR T-TAP THIS WIRING LINK. ALL CIRCUITS NEED TO BE LANDED IN THESE PANELS PER LUTRON'S PANEL SCHEDULES. • THE MAXIMUM WIRE LENGTH OF A PANEL LINK IS 2,000 ft (600 m). A MX-RPTR IS USED TO EXTEND THE LENGTH OF A LINK ANOTHER 2,000 ft (600 m). A MAXIMUM OF (3) MX-RPTR'S MAY BE USED PER LINK FOR MAXIMUM LENGTH OF 8,000 ft (2,430 m) PER LINK. • IF A PANEL IS MOVED TO ANOTHER LINK, OR THE LOADS ARE NOT WIRED AS SHOWN IN LUTRON PANEL SCHEDULES, LUTRON MUST BE NOTIFIED. THIS INFORMATION IS IMPORTANT FOR PROGRAMMING THE SYSTEM. • UP TO 32 CIRCUIT SELECTORS PER LINK • UP TO 512 SWITCH LEGS OR ZONES PER LINK • LT-1 LINK TERMINATORS NEEDED ON EACH END OF THE LINK LED DIMMING REQUIRES AN EXACT MATCH BETWEEN THE LED ARRAY, DRIVER AND CONTROL. LUTRON CANNOT GUARANTEE COMPATIBILITY OR PERFORMANCE WITHOUT TESTING THIS COMBINATION. TO CONFIRM WHAT PRODUCTS LUTRON HAS AVAILABLE OR WHAT INTERFACES MAY BE REQUIRED, CALL 1-877-DIM-LED8 OR CHECK LUTRON'S PRODUCT COMPATIBILITY MATRIX ON-LINE AT WWW.LUTRON.COM/LED. TO REQUEST THE TESTING OF AN LED PRODUCT BY LUTRON MANUFACTURERS CAN FILL OUT AN LED EVALUATION REQUEST FORM ON-LINE AT WWW.LUTRON.COM/LED OR CONTACT LEDS@LUTRON.COM. LUTRON CAN GUARANTEE COMPATIBILITY AND PERFORMANCE OF LUTRON HI-LUME A -SERIES LED DRIVERS USED WITH APPROPRIATE LUTRON CONTROLS. THE HI-LUME A -SERIES LED DRIVER CAN BE USED ON PRODUCTS UNDER 40 WATTS WITH SUITABLE MOUNTING LOCATIONS. PLEASE REFER TO THE SPECIFICATION SUBMITTAL SHEET FOR FURTHER INFORMATION. IF USING UNTESTED, NON-LUTRON LED DRIVERS REQUIRING 0-10V CONTROL, PERFORMANCE AND COMPATIBILITY CANNOT BE GUARANTEED BY LUTRON. PRODUCTS FOLLOWING THE IEC STANDARD 60929 ARE MORE LIKELY TO PROVIDE ACCEPTABLE PERFORMANCE RESULTS. DETERMINATION OF RESULT ACCEPTABILITY IS UP TO THE USER'S DISCRETION. IF USING UNTESTED, NON-LUTRON LED DRIVERS REQUIRING PHASE CONTROL, PERFORMANCE AND COMPATIBILITY CANNOT BE GUARANTEED BY LUTRON. A -SERIES OR ELV PRODUCTS PROVIDING HIGH END AND LOW END TRIM ADJUSTMENTS ARE MORE LIKELY TO PROVIDE ACCEPTABLE PERFORMANCE RESULTS. DETERMINATION OF RESULT ACCEPTABILITY IS UP TO THE USER'S DISCRETION. ELECTRICAL DETAILS SCALE: NOT TO SCALE E II � C&K ARCHITECTS I INTERIORS architecture • interior design • client services AAC001629 4221 WEST BOY SCOUT BLVD., SUITE 150 TAMPA, FL 33607-5743 813.884.2000 280 WEST CENTRAL AVE. WINTER HAVEN, FL33880-2957 863.577.2054 Q J• F f �- � �\CENSF.•.F� ��. Q 65083. 5/1 2021 ° W O STATE OF F •••••:�C•0R \ 0 P� 'G� SS/ONAL•�� 0 N s r mQ 0 O z I.L. J J a w N W 0 W � Q �O V_ a N 0`' i V m LU m i LU 1100 m Q C9 M to 0, ISSUED FOR; PERMIT PROJECT NUMBER 21020 DATE 5.5.21 DRAWING NUMBER E9III i - rr —7-r-FIF r i l � — _ -1 11 1- 1 1 11iu: f i, 1 i 11 11 1 11110 li iri,a. aril, Aflil.E i -,i i i I A i,usi i I I i I I T i STANDARD FIRE ALARM ABBREVIATIONS A AMPS AC ALTERNATING CURRENT ADA AMERICANS WITH DISABILITY ACT AH AMP HOUR AWG WIRE SIZE (GAUGE) cd CANDELA (STROBE INTENSITY) CFM CUBIC FEET PER MINUTE (AIR FLOW) CLASS CIRCUIT CONFIGURATION (A OR B) DC DIRECT CURRENT DH MAGNETIC DOOR HOLDER EOL END OF LINE RESISTOR EMF ELECTROMAGNETIC FORCE EMT METAL ELECTRICAL CONDUIT ETR EXISTING TO REMAIN FORM-C DOUBLE -THROW RELAY FPL FIRE POWER LIMITED FACP FIRE ALARM CONTROL PANEL FWR FULL WAVE RECTIFIED GF GROUND FAULT IDC INITIATING DEVICE CIRCUIT LED LIGHT EMITTING DIODE mA MILLIAMPS (CURRENT) NAC NOTIFICATION APPLIANCE CIRCUIT NEC NATIONAL ELECTRICAL CODE NC NORMALLY CLOSED RELAY CONTACT NO NORMALLY OPEN RELAY CONTACT NPL NON POWER LIMITED PL POWER LIMITED POTS PLAIN OLD TELEPHONE SERVICE PSE POWER SUPPLY EXPANDER REL RELOCATED RFI RADIO FREQUENCYINTERFERENCE RJ45 TELEPHONE JACK CONNECTION SLC SIGNALING LINE CIRCUIT TS FIRE VALVE TAMPER SWITCH TSP TWISTED SHIELDED PAIR uA MICROAMPS V VOLTS VA VOLT AMPS (POWER) W WATTS (POWER) WFS FIRE SPRINKLER WATERFLOW SWITCH PROGRAMMING MATRIX FOR ALL BUILDINGS 24" MIN HANDICAP BEDROOM STROBE TWO OR MORE APPLIANCES IN THE SAME ROOM OR ADJACENT SPACE WITHIN THE FIELD OF VIEW SHALL FIRE ALARM DEVICE MOUNTING GUIDE T-0" (MIN) PER NFPA 72 ____1 CEILING MOUNTED SMOKE/HEAT A/C SUPPLY DIFFUSER DETECTOR AUDIOVISUAL CEILING MOUNTED NOTIFICATION — &VISUAL -ONLY DEVICE (TO BE WHITE). DEVICES SEE PLAN FOR LOCATION. EILI ACCEPTABLE HERE' DO NOT INSTALL IN THIS AREA WALL MOUNTED HEAT DETECTOR TO THE BOTTOM WALL MOUNTED SMOKE DETECTOR TO THE TOP FLASH IN SYNCHRONIZATION 5'-0" MANUAL MAX FROM EXIT DOOR PULL 6" 80" MIN - 96" MAX FIRE STATION 6 NFPA 72, 2016 PHONE O° EDITION (SECTION JACK 1 8.5.5) DUCT MAGNETIC DETECTOR DOOR REMOTE TEST HOLDER • o �. o 48" (ADA) TO THE WORKING MECHANISM 48" ALSO MEETS THE REQUIREMENTS OF NFPA 72, 2016 EDITION FINISHED (SECTION 17.14.5) FLOOR IMPORTANT NOTE NOT ALL DEVICES SHOWN ON THIS DETAIL APPLY TO THIS PROJECT. SEE THE PLAN VIEW LAYOUT OF THE FIRE ALARM SYSTEM TO VERIFY WHICH DEVICES APPLY, AND WHICH DO NOT. OUTPUTS • 4 4" 1 12" (MAX) ANNUNCIATOR APPROXIMATELY 5'-0" (60") AFF NOTE CHECK WITH MANUFACTURER'S INSTALLATION SHEET FOR THE EXACT ROUGH -IN HEIGHTS, LOCATION OF BACK BOXES, AND WIRING REQUIREMENTS. ISO owl, ff Kid, R. Me 01 IN I MAIN CONTROL PAREL-FuNcTiONs FIRE ALARM L#W 8ATTERY FIRE ALARM AC POWER FAILURE 41?�EN CIRCUIT GROUND FAULT NOTIFICATION SHORT CIRCUIT PULL STATION DUCT DETECTOR HEAT DETECTOR rmujr-k, 1 or-mt iriu rvv 1 r-o. 1. THIS CHART IS TO BE USED AS A BASIC PROGRAMMING GUIDE ONLY. ALL OTHER PANEL PROGRAMMING FEATURES SHALL COMPLY WITH NFPA 72 AND THE MANUFACTURERS INSTRUCTIONS. FIRE ALARM SPECIFICATIONS - 51G15 PART 1 - GENERAL 0.01 GENERAL SCOPE A. THIS PROJECT CONSISTS OF MODIFICATIONS TO AN EXISTING CONVENTIONAL FIRE ALARM SYSTEM. B. OCCUPANCY TYPE: A-2 C. OCCUPANT LOAD: 56 D. PATHWAY SURVIVABILITY: LEVEL 0 1.01 GENERAL DOCUMENTS A. THESE PLANS WERE PREPARED WITH THE INTENT OF NFPA 72 (2016 ED.), NFPA 70 (2017 ED.), FLORIDA FIRE PREVENTION CODE (7TH ED.), AND/OR THE REQUIREMENTS OF THE LOCAL AUTHORITY HAVING JURISDICTION. B. THE FIRE ALARM WORK SHALL INCLUDE FURNISHING ALL LABOR, EQUIPMENT, MATERIALS AND SERVICE NECESSARY FOR AND REASONABLY INCIDENTAL TO THE PROPER COMPLETION OF ALL FIRE ALARM WORK SHOWN ON THE DRAWINGS AND AS SPECIFIED. ALL MATERIAL SHALL BE NEW. C. THIS SUBMITTAL IS NOT A COMPLETE DESIGN. ONLY THE REQUIREMENTS OF 61G15-32.008 AND 61G15-33.006. 1.02 SHOP DRAWINGS AND SUBMITTALS A. THE FIRE ALARM CONTRACTOR SHALL PREPARE A COMPLETE SET OF FIRE ALARM SHOP DRAWINGS FOR ALL AREAS IN WHICH THE ENGINEER DOES NOT PROVIDE A COMPLETE DESIGN. THE SHOP DRAWINGS SHALL BE PREPARED ACCORDING TO THE REQUIREMENTS OF NFPA 72 10.18 AND A.10.18 AND SHALL BE REVIEWED FOR CONFORMANCE TO THOSE REQUIREMENTS BY THE ENGINEER OF RECORD. THE SHOP DRAWINGS SHALL BE REVIEWED BY THE ENGINEER AND STAMPED "APPROVED", "APPROVED AS NOTED", OR "REJECTED". THE ENGINEER SHALL NOT SIGN AND SEAL ANY SHOP DRAWINGS (IN VIOLATION OF STATE LAW). B. THE FIRE ALARM CONTRACTOR SHALL COMPLETE VOLTAGE DROP/LOAD CALCULATIONS FOR ANY MODIFIED CIRCUITS. C. THE FIRE ALARM CONTRACTOR SHALL PROVIDE ADDITIONAL CIRCUITS AND/OR POWER SUPPLIES AS NEEDED FOR ALL CIRCUITS TO PASS VOLTAGE DROP/LOAD CALCULATIONS. D. THE FIRE PROTECTION ENGINEER OF RECORD MAY FURNISH THE FIRE ALARM CONTRACTOR, UP TO FOUR (4) SETS OF 61G15 ENGINEERING DOCUMENTS BEARING THE SEAL OF THE ENGINEER, FOR PERMITTING. CONTRACTOR SUBMITTALS WHICH DEVIATE FROM THE DESIGN SHOWN IN THIS PLAN SET SHALL BE CONSIDERED A MATERIAL DEVIATION. E. MATERIALS OR PRODUCTS SPECIFIED HEREIN AND/OR INDICATED ON DRAWINGS BY TRADE NAME, MANUFACTURER'S NAME OR CATALOG NUMBERS SHALL BE INTERPRETED AS ESTABLISHING A STANDARD OF QUALITY AND DESIGN. F. THE FIRE ALARM CONTRACTOR SHALL NOT SUBSTITUTE DEVICES OR EQUIPMENT, DOWN SIZE WIRING OR DELETE EQUIPMENT SHOWN IN THIS PLAN SET WITHOUT THE ENGINEERS APPROVAL AND THE WRITTEN APPROVAL OF PROJECT MANAGER FOR THE OWNER. 1.03 RECORD DRAWINGS A. THE FIRE ALARM CONTRACTOR SHALL BE REQUIRED TO SUBMIT A "RECORD OF COMPLETION", PER NFPA 72 AND THE FLORIDA ADMINISTRATIVE RULE #60A-48, TO THE OWNER PRIOR TO FINAL PAYMENT. B. THE FIRE ALARM CONTRACTOR IS REQUIRED TO MAINTAIN A COMPLETE AND ACCURATE AS -BUILT DRAWING SET. UPON FINAL COMPLETION OF THE PROJECT, THE FIRE ALARM CONTRACTOR SHALL SUPPLY THE OWNER WITH AN AS -BUILT SET PRIOR TO FINAL PAYMENT. AN AS -BUILT SET OF DRAWINGS SHALL BE POSTED AT THE FIRE ALARM PANEL AT THE COMPLETION OF THE WORK. C. THE AS -BUILT DRAWINGS SHALL INCLUDE DEVICE NUMBERS AS PROGRAMMED INTO THE PANEL FOR ALL INITIATION AND NAC DEVICES AS REQUIRED BY STATE FIRE MARSHAL RULE 69A-48.007(1). PART 2 - INSTALLATION 2.01 SPECIFIC REQUIREMENTS A. SECONDARY POWER SHALL CONSIST OF RECHARGEABLE BATTERIES HAVING A CAPACITY TO POWER THE ALARM SYSTEM FOR A PERIOD OF 24 HOURS IN A STANDBY MODE AND OPERATE ALL NOTIFICATION APPLIANCES FOR 5 MINUTES AT THE END OF THE 24 HOUR PERIOD. B. THE ALARM SYSTEM HAS BEEN DESIGNED WITH A CLASS "B" SIGNALING LINE CIRCUIT (SLC). THE NOTIFICATION ALARM CIRCUITS (NAC) HAVE BEEN DESIGNED FOR CLASS "B" OPERATION. THE SLC IS POWER LIMITED.THE SMOKE DETECTORS SHALL NOT BE INSTALLED PRIOR TO THE SYSTEM PROGRAMMING AND TEST PERIOD. IF CONSTRUCTION IS ONGOING DURING THIS PERIOD, MEASURES SHALL BE TAKEN TO PROTECT THE SMOKE DETECTOR FROM CONTAMINATION AND PHYSICAL DAMAGE UNTIL CONSTRUCTION ACTIVITIES ARE COMPLETE. C. ALL EXPOSED RISERS TO THE FACP, AUXILIARY POWER SUPPLIES, INITIATING DEVICES AND/OR NOTIFICATION APPLIANCES SHALL BE INSTALLED IN EMT. D. NOTIFICATION HORN/STROBES SHALL BE MOUNTED SO THAT THE FIRE ALARM WIRE LEGEND SYMBOL CIRCUIT DESCRIPTION WIRE SIZE WIRE TYPE A SIGNALING LINE LOOP (2) #18 FPLR A4 REMOTE ANNUNCIATOR (4) #18 FPLR B NOTIFICATION APPLIANCE CIRCUIT (2) #14 FPLR D REMOTE TEST SWITCH (2) #16 FPLR I INITIATING DEVICE CIRCUIT (2) #16 FPLR K REMOTE ANNUNCIATOR (6) #16 FPLR Q 120 VAC POWER CIRCUIT (3) #12 THHN R 24 VDC POWER LIMITED CIRCUIT (2) #14 FPLR S S-BUS (4) #16 FPLR U UNDERGROUND CONDUIT WIRING (2) #16 TFFN* X SPARE WIRE PAIR (2) #16 FPLR Y SPARE WIRE PAIR (2) #14 FPLR NAC CIRCUIT NUMBERING SCHEME FIRE ALARM CONTROL PANEL OR POWER SUPPLY PANEL NAC CIRCUIT NUMBER ON PANEL PSE-N1-1 DEVICE NUMBER ON NAC 7 Icd CIRCUIT CANDELA RATING ENTIRE LENS OF THE DEVICE IS NO LESS THAT 80" AFF AND NO GREATER THAN 96" AFF. E. ALL NEW ADDRESSABLE PULL STATIONS SHALL BE INSTALLED AT 48 INCHES ABOVE THE FINISH FLOOR TO TOP. F. ALL WIRING CONNECTIONS SHALL BE IN SINGLE, DOUBLE, TRIPLE OR 4 GANG ELECTRICAL BOXES, AS NEEDED. G. ALL WIRING ON THE INITIATION AND NOTIFICATION CIRCUITS ARE POWER LIMITED. 2.02 CONDUIT AND WIRE I. CONDUIT: A. CONDUIT SHALL BE IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE (NEC-70), LOCAL AND STATE REQUIREMENTS. COMPLY WITH ADDITIONAL REQUIREMENTS IN THE DRAWINGS. B. CONDUIT FILL SHALL NOT EXCEED 40 PERCENT OF INTERIOR CROSS SECTIONAL AREA WHERE THREE OR MORE CABLES ARE CONTAINED WITHIN A SINGLE CONDUIT. C. CABLE MUST BE SEPARATED FROM ANY OPEN CONDUCTORS OF POWER, OR CLASS 1 CIRCUITS, AND SHALL NOT BE PLACED IN ANY CONDUIT, JUNCTION BOX OR RACEWAY CONTAINING THESE CONDUCTORS. II. WIRE: A. ALL FIRE ALARM WIRING SHALL BE PER THE FIRE ALARM WIRE LEGEND. B. WIRING SHALL BE IN ACCORDANCE WITH LOCAL, STATE AND NATIONAL CODES (E.G., NEC ARTICLE 760). NUMBER AND SIZE OF CONDUCTORS SHALL BE AS RECOMMENDED BY THE FIRE ALARM SYSTEM MANUFACTURER, BUT NOT LESS THAN 16 AWG FOR INITIATING DEVICE CIRCUITS AND 14 AWG FOR NOTIFICATION DEVICE CIRCUITS. C. ALL FIELD WIRING OF INITIATION (AS APPLICABLE) AND NOTIFICATION CIRCUITS ARE TO BE COMPLETELY SUPERVISED BY END OF LINE DEVICES, PER THE MANUFACTURER'S LITERATURE. D. ALL RISER WIRING AND EXPOSED AREA WIRING FOR THE ALARM SYSTEM SHALL BE IN EMT. E. TERMINAL_ BOXES, JUNCTION BOXES AND CABINETS: ALL BOXES AND CABINETS SHALL BE UL LISTED FOR THEIR USE AND PURPOSE. F. THE FIRE ALARM CONTROL PANEL IS TO BE CONNECTED TO A SEPARATE DEDICATED BRANCH CIRCUIT, MAXIMUM 20 AMPERES. THIS CIRCUIT SHALL BE LABELED AT THE MAIN POWER DISTRIBUTION PANEL AS FIRE ALARM. FIRE ALARM CONTROL PANEL PRIMARY POWER WIRING SHALL BE 12 AWG. THE CONTROL PANEL CABINET SHALL BE GROUNDED SECURELY TO EITHER A CONDUIT, COLD WATER PIPE, OR GROUNDING ROD. A 120 VOLT SURGE SUPPRESSER SHALL BE INSTALLED ON THE AC POWER AND GROUNDED PRIOR TO ENTERING THE FIRE ALARM CONTROL PANEL. THE BREAKER FOR THE ALARM CIRCUIT SHALL BE RED IN COLOR OR PAINTED RED AND SHALL BE PROVIDED WITH A LOCKING TAB INSTALLED TO PREVENT SHUTTING OFF THE BREAKER. PART 3 - EXECUTION 3.01 INSTALLATION A. INSTALLATION SHALL BE IN ACCORDANCE WITH THE NEC, NFPA 72, LOCAL AND STATE CODES, AS SHOWN ON THE DRAWINGS, AND AS RECOMMENDED BY THE MAJOR EQUIPMENT MANUFACTURER. 3.02 FINAL INSPECTION A. AT THE FINAL INSPECTION A FACTORY TRAINED REPRESENTATIVE OF THE INSTALLER SHALL DEMONSTRATE THAT THE SYSTEMS FUNCTION PROPERLY IN EVERY RESPECT AND PROVIDE FULL TRAINING. ALL TESTING REQUIRED BY THE AHJ AND NFPA 72 SHALL BE COMPLETED IN THE PRESENCE OF THE LOCAL FIRE AUTHORITY, AS REQUIRED. 3.03 WARRANTY A. THE FIRE ALARM CONTRACTOR SHALL WARRANT ITS WORK TO BE FREE FROM DEFECTS IN MATERIALS AND WORKMANSHIP FOR A PERIOD OF ONE YEAR FROM FINAL ACCEPTANCE OF ALL WORK.THE FIRE ALARM CONTRACTOR SHALL PROVIDE ALL MANUALS TO OWNER. 3.04 IMPAIRMENTS A. BEFORE SHUTTING OFF A SECTION OF THE FIRE ALARM SYSTEM TO MAKE SYSTEM CONNECTIONS, NOTIFY THE AUTHORITY HAVING JURISDICTION, PLAN THE WORK CAREFULLY, AND ASSEMBLE ALL MATERIALS TO MINIMIZE DOWN TIME. 3.05 MAINTENANCE A. THE SYSTEM SHALL BE MAINTAINED IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS PER NFPA 72-14.5. 3.06 DOCUMENTATION B. THE FIRE ALARM CONTRACTOR SHALL PROVIDE SYSTEM RECORD OF COMPLETION PER NFPA 72-7.5. FIRE ALARM SHEET INDEX I=A0.1 — FIRE ALARM GENERAL FA2.1 — FIRE ALARM DEMO PLAN FA4.1 — FIRE ALARM PROPOSED PLAN 0=AW — NOT USED I: A7.1 — NOT USED FASA — NOT USED FA0. 1 — NOT USED C&K ARCHITECTS INTERIORS architecture -interior designclient services NOW mill 1E■ N■NNI NINE.. 11111 111 1N■I■, IN N■NNI-mill 111.101.1111 MEN mill N1■11E1 MEN. 112111 m■NNI. 11 n■1m-■!mm �Q J Fe Q o. 5083 °ems i 5 021 0 '., STATE OF <v ss� ON A,`. Z 0 s �a 0 0 Z J LL J J_ n. w N J � O Z LU V �O w �o 1., 0 Cm W Cie 0 J m J 0 N) 01 LO 1I11111111 PERMIT ii■11liNl■NIl 21020 10111 5.5.21 lm ill1IEl1N FAOIN 1 11 1 1 11 .:I 11 I I li,I . Ai.L II ]; III .919uiltil0t&.I�I:@,, IL lk li.'i!I.IIIF I,III I01 II I II fl : I I I I — — — — — — — — — — — — — — — — — — — — — — — — LFX --I---- — — -1-- — —I— — 4 — — —I— — 4 — — —I— — 4 — — —I— — - —I— — -T — — T-7— — 7 — — i I —I— -T F —1— 7 —F -T T —I- -I— — 4 — — —I— — 4 — —I— — 4 — — —I— — 4 — — 4-- — —I— — 4 — — —I— — - —I— -T —1— 7 7 —1— -T T- —I- 71 -T — — —I— — 4 — — —I— — 4 — — -k- — —I— — 4 — — F -1 +- --I— — 4— — —I— — 4 — — -1-- — —I— — - T- —I— -T T- —1— 7 r —1— 7 7 —1— -T T- —I- ---"-,T — i--I---1---T7 II I —i L —I— —i L —I— —i —I— — 4 — —:—/\4 4 -T T- —I -T T- _—'--- LLL J d 0) 1 -1 L � #1 15cd L -F = E — -t- — -T Irm all 4Na #w W.3 ;11,171111111] SCALE: 1/4" = V-101" FACIP KEY PLAN SCALE: NOT TO SCALE C&K ARCHITECTS I INTERIORS architecture. interior design. client services AAC001629 4221 WEST BOY SCOUT BLVD., SUITE 150 TAMPA, FL 33607-5743 813.884.2000 280 WEST CENTRAL AVE. WINTER HAVEN, FL 33880-2957 863.577.2054 3. Fc-1 ......... 14r- 2 -1 .5 0'.. STATE OF 4j .......... ON At. mQ 'Ak C; LL Lu z 0 0 LLI CQ 0 ON Lu 0 LIJ Ce LL ca 01 01 LO ISSUED FOR: PERMIT PROJECT NUMBER 21020 DATE 5.5.21 DRAWING NUMBER FA2 I NEW DEVICE LEGEND DEVICE SYMBOL QTY. DESCRIPTION SS LV 1 SURGE PROTECTOR V 1 DUCT SMOKE DETECTOR O 1 PHOTOELECTRIC SMOKE DETECTOR 2 STROBE ®4 4 2-WIRE, HORN STROBE WP 1 2-WIRE HORN/STROBE OUTDOOR EXISTING DEVICE LEGEND DEVICE SYMBOL QTY. DESCRIPTION ® 1 MANUAL PULL STATION Ell 1 2-WIRE, HORN STROBE KEYED NOTES COORDINATE FINAL LOCATION WITH GC MANUAL PULL STATION SHALL BE LOCATED WITHIN 5' OF EXIT DOORWAY PER FFP 9.2.6.3 0 CONTRACTOR TO PROVIDE MULLION BOX TO MOUNT PULL STATION. MULLION BOX WILL CONCEAL WIRES THAT ROUTE FROM PULL STATION INTO STOREFRONT VERTICAL MEMBER. OINSTALL DUCT SMOKE DETECTOR IN SUPPLY AIR DUCT O (TYPICAL) COMMUNICATIONS PER NFPA 72, CHAPTER 26. LINETYPE LEGEND SLC CIRCUIT (1-A) NAC CIRCUIT (1-N) S-BUS CIRCUIT (1-S) INITIATION CIRCUIT (1-1) TIE IN TO EXISTING SLCLOOP-- -- -- -- -- S-- NEW NEW NEW TIE IN TO EXISTING NAC CIRCUIT. ]PROVIDE PSE AS NEEDED. 75cd 30cd 75cd 15cd 15cd 15cd 15cd 30cd NEW NEW WP REL NEW NEW NEW NEW NEW FIRE ALARM RISER DIAGRAM SCALE: NOT TO SCALE L- -j 0NEW1 F-1 L - --J I I El 1:1 75cd NEW ------------------ I— —� — — — —— —CFI-—l(—_II_—ll7-------SF--- --F III II II III �— I I I I �— �� (^1 II �- --� II-----=== I I J SERVICE 30cd LINE NEW I I 101 Ii------------------7 I I I I -1 ---_--1--II— IF—�F--fiF--- �JDJ IF �� IF — II II II III 15cd NEW NOMENS 1Vff 0 0 0 MENS 105 1 k LE OFFICE I Io3 I I �--T---1 �\j I I I l I 30cd ( I NEW6FIe I I I I I I I I KI CNEN o l 102 n NEW ----J �—U 15cd + o I NEW I F --7 I L- I I R2 —I I I I I I I I I I ( ( NEWCS I I I I I I 15cd _ _ I I EL I (i — i) I II ETR ^5cd�` E REL LV' — I II SCALE: 1/4" = 1'-0" 75cd WP NEW TIE ANSUL HOOD SYSTEM DIRECTLY INTO FIRE ALARM PANEL ZONE INPUT FOR PANEL MONITORING. HOOD SHALL ACTIVATE HOOD SUPPRESSION SYSTEM AND GAS/POWER SHUTDOWN INDEPENDENTLY OF FIRE ALARM. KEY PLAN SCALE: NOT TO SCALE i C&K ARCHITECTS I INTERIORS architecture• interior design. client services AAC001629 4221 WEST BOY SCOUT BLVD., SUITE 150 TAMPA, FL 33607-5743 813.884.2000 280 WEST CENTRAL AVE. WINTER HAVEN, FL33880-2957 863.577.2054 0 Z �Q 3. Fe, �' • �\CE IVSF �F� U m Q • O. 5083 e. u 2021. W ' 0.. ,n• STATE OF ; 44 F•••:% �OR1p''v� w SS 0NAL a 0 0 0 z a 2 0 0 m 0 Q Z o 0 z <_ S � 1= 0 z o ma o a d r z J LL � U J� a ¢ J_ = x Z N Z a O � w w W O o O acn z � 0 a CL w a N � O a a a w m Q = a Cal ¢ W 0 a LL. o c m J V ¢ � z M 01 LO z C ISSUED FOR: C PERMIT z PROJECT NUMBER a - 21020 Z Z DATE z C 5.5.21 C DRAWING NUMBER s FA4 U G O z a i= z a I,1 Z O U