HomeMy WebLinkAbout2801 E SR 60FIRE ALARM SYSTEM DEVICE LEGEND SYMBOL DESRIPTION COMMENT PRODUCT I.D. MOUNTING HEIGHT ELEC. BOXMj FIRE ALARM CONTROL VIGILANT SERIES VS1-RD 72" AFF TO TOP FACP PANEL WITH DACT OF CONTAINER MFR. FIRE ALARM REMOTE VIGILANT SERIES RLCD-R 60" AFF TO TOP FAAP ANNUCIATOR PANEL OF CONTAINER MFR. BPS FIRE ALARM REMOTE VIGILANT SERIES MIRBPS6A BESIDE FACP MFR. POWER SUPPLY ADDRESSABLE MANUAL VIGILANT SERIES 42" TO 48" AFF PULL STATION GSA-M278 DOUBLE ACTION NOTE 2 C z O ADDRESSABLE VIGILANT SERIES CEILING B SMOKE DETECTOR V-PD WITH K1-SB BASE MOUNT ADDRESSABLE SUPP./ VIGILANT SERIES GSA -SD DUCT S/R RTN. SIDE DUCT DET. WITH SD-T60 SAMPLING TUBES MOUNTED D R DUCT DETECTOR VIGILANT SERIES GSA -SD CEILING C REMOTE TEST SWITCH WITH SD-TRM MOUNT 0 ADDRESSABLE VIGILANT SERIES PROVIDE DRY E MONITOR MODULE GSA-CT1 ENCLOSURES ❑M ADDRESSABLE DUAL VIGILANT SERIES PROVIDE DRY E 2 MONITOR MODULE GSA-CT2 ENCLOSURES C R ADDRESSABLE VIGILANT SERIES PROVIDE DRY E RELAY MODULE GSA-CR ENCLOSURES 0 F SPRINKLER FURNISHED BY OTHERS FIELD LOCATE D �--do-� FLOW SWITCH MONITORED BY NEW FACP PER FLOOR PLANS T SPRINKLER FURNISHED BY OTHERS FIELD LOCATE TAMPER SWITCH MONITORED BY NEW FACP PER FLOOR PLANS D WALL MOUNT WHEELOCK EXCEDER LHS3 SERIES 82" AFF TO C HORN STROBE (*) CANDELA RATING BOTTOM OF LENS CEILING MOUNT WHEELOCK EXCEDER LHSC3 SERIES CEILING HORN STROBE (*) CANDELA RATING MOUNT C CLG. MOUNT W.P. WHEELOCK ASWP-2475W-FR SERIES 82" AFF TO �WALL p HORN STROBE 115 CANDELA RATING BOTTOM OF LENS WBB WALL MOUNT W.P. WHEELOCK ASWP-2475C-FR SERIES 82" AFF TO HORN STROBE 115 CANDELA RATING BOTTOM OF LENS WBB WP CLG. CEILING MOUNT WHEELOCK EXCEDER LSTC3 SERIES CEILING C STROBE (*) CANDELA RATING MOUNT CLG. S�-� FIRE ALARM 120VAC DITEK DTK-120HW SERIES FIELD LOCATED 120 CIRCUIT PROTECTOR AT FACP/BPS D MFR. DENOTES BACKBOX FURNISHED BY MANUFACTURER AFF DENOTES ABOVE FINISHED FLOOR WBB DENOTES WEATHERPROOF BACKBOX BACKBOXES REQUIRED BY OTHERS 2-1 /8" 4>, SQ 2-1 /8" 1-1 /2,> DEEP DEEP DEEP 4" SQ. 1-1/2" BLANK SINGLE 4-1 1 /16" 4-1 1 /16" OCTAGON EXT. RING PLATE GANG BOX SQ. BOX EXT. RING BOX BACKBOX SCHEDULE A - 4" BOX WITH SINGLE GANG RING B - 4" BOX WITH ROUND RING OR OCTAGON BOX C - 4" BOX 2-1 /8" DEEP WITH SGPR D - 4" BOX ADJACENT FLEX TO DEVICE E - 4" BOX 2 1/8" DEEP WITH EXTENSION BOX GENERAL NOTES SYSTEM INSTALLATION IN ACCORDANCE WITH 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE FLORIDA SPECIFIC ADDITION OF NFPA 1, THE FIRE CODE (2015) NATIONAL ELECTRIC CODE (2014 EDITION) NFPA 72 (2013 EDITION) NATIONAL FIRE ALARM SIGNALING CODE - FLORIDA SPECIFIC EDITION OF NFPA 101 NFPA 101 (2015 EDITION) FLORIDA ADMINISTRATIVE CODE 61 G15-32 ALL OTHER CODES MANDATED BY THE LOCAL AUTHORITY HAVING JURISDICTION 1) FIRE ALARM SYSTEM WIRING: STYLE B (CLASS B) INITIATION DEVICE CKTS. STYLE Y (CLASS B) NOTIFICATION APPLIANCE CKTS. STYLE 4 (CLASS B) ADDRESSABLE SIGNALING LINE 2) LOCKBOX TO BE MOUNTED OUTSIDE OF THE BUILDING WITHIN 6' OF PRIMARY ENTRANCE DOOR AND AT A HEIGHT NOT TO EXCEED 12' AFF .NOR BE LESS THAN 8' AFF TO BOTTOM OF BOX. KEYBOX SHALL BE ZONED INDEPENDENTLY IF REQUIRED BY THE LOCAL AUTHORITY FIRE ALARM SYSTEM BATTERY CALCULATION VIGILANT SERIES VS1 -RD (FACP) ITEM QTY DESCRIPTION STANDBY ALARM STANDBY ALARM per unit per unit Total Total A 1 MASTER CONTROLLER 0.155 0.204 0.155 0.204 B 1 REMOTE ANNUCIATOR 0.036 0.146 0.036 0.146 C 18 ADDRESSABLE DEVICES 0.0005 0.0005 0.009 0.009 D 1 FULL LOAD NOTIFICATION 0.000 3.750 0.000 3.750 E 3 AUX. 24VDC RELAY 0.000 0.015 0.000 0.045 TOTAL DRAW AMPS 0.200 4.154 STANDBY FOR 24 HOURS AMPS 4.800 ALARM FOR 5 MINUTES AMPS .347 TOTAL BATTERY IN AMPS REQUIRED 5.147 X 1.2 FACTOR 6.177 BATTERIES SUPPLIED 7.0 AMP HOUR NOTIFICATION CIRCUITS FUSED AT 2.5 AMPS VIGILANT SERIES MIRBPS6A (PCPs) ITEM QTY DESCRIPTION STANDBY ALARM STANDBY ALARM per unit per unit Total Total A 1 MASTER CONTROLLER 0.175 0.270 0.175 0.270 B NOTIFICATION CIRCUIT 1 0.000 1.022 0.000 1.022 C 1 NOTIFICATION CIRCUIT 2 0.000 1.109 0.000 1.109 p 1 NOTIFICATION CIRCUIT 3 0.000 1.511 0.000 1.511 E 1 NOTIFICATION CIRCUIT 4 (SPARE) 0.000 0.000 0.000 0.000 TOTAL DRAW AMPS 0.175 3.912 STANDBY FOR 24 HOURS AMPS 4.200 ALARM FOR 5 MINUTES AMPS .326 TOTAL BATTERY IN AMPS REQUIRED 4.526 X 1.2 FACTOR 5.432 BATTERIES SUPPLIED 7.0 AMP HOUR NOTIFICATION CIRCUITS FUSED AT 3.0 AMPS ELECTRICAL/MECHANICAL ROOM nRKA cVCTFt\A RIcr-R 111A(_RANA 00 MAIN ENTRANCE 001 FIRE ALARM FUNCTIONAL MATRIX:..Of Of U-3 m 2f -cc M W cn W CUj cn / CONTROL UNIT ANNUNCIATION NOTIFICATION SUPPLEMENTARY o Q r o o U J � J J Q O Q Z I - ALL WORK SHALL Ct:MFLY WITH NFFA CODES AND STANDARDS If REVIEW DATE CITY OF ZEPHYRHIL` lS FIRE AND LIFE SAFETY EXAMINER_______ P.E. STAMP 1 o • • yy . y z rrr ty;� � q Q O C DRAWN BY: DQDD APPROVED BY: DATE: 11 /21 /19 SCALE: AS INDICATED PROJECT N0: Al DEVICE LEGEND BATTERY CALCS. RISER DIAGRAM FA-1 WALK IN WALK IN GAS METER COOLER COOLER WALK IN UNIT UNIT FREEZER 00 00000000 D ° Q <1 fl O WALK IN COOLER W LL1 wo w wY 4 ° � e o WP ; 00000 % ° 0 LU 51-2 m 0 o D `0 115cd o CLG. ° m� B 0 0W� Z p 0 > gQ1� WALK IN F EZER 0 Z 0 i w owo0� W J Z w Un0 ¢> e % ° S1-3 115cd WID w>_ ° ° CLG. w >_mm W w J o NOTIFICATION SPACING BASED ON MAXIMUM SMOOTH CEILING HEIGHT OF 20'-0" RINNAI MODEL CU160E NATURAL AREA IS PROTECTED BY AN AUTOMATIC FIRE PROTECTION SPRINKLER SYSTEM MONITORED BY THE HOUSE FACP GAS ON DEMAND WATER HEATER UNIT#1 UNIT#2 E7 7TV Tc T 10'0" A.F.F. VERIFY HEIGHT wo O > U)z 0 � D o 0 w 00 <x o; m70 m W Z00 C3 c co 0 o = � r m r m oIr wo '1 ° > n O D D O D ;a El a a e om >z B a M--i ° >- Oz �O WAL IN COOLER o= ° a ° ©,� CORNELIUS NORDIC UNDER COUNTER o z z� S 1 -4 CUBE ICE MACHINE 309L8 PER DAY '® 30" WIDE 30" DEEP 39" TALL 115cd CLG. WID D a 36" X21"ICE BIN BY OTHERS u D P D= 3D D. O O o 4® B o GFl x Jw co 00 ® wg w S.S. PREP HAND WASH m ABLE 60"X30" SINK 0-0 O 0 COFFEE MACHINE WITH of O a ow COLD WATER LINE AND w a DRAIN CONNECTION _ coWm 0?z: DRPY--0120 z O� FRYER S1-5 � U) 0- DRPY0120 75cd 0, O a ¢ FRYER CLG. 0Cl) 6 w DRPY-0120-THRU 6" ABOVE PASS COUNTER w FRYER o w wow �LLoo GAS ag o 0 DRPY-0120 FRYER rOaw p z w o n-x m aw J z N A m F zC0 Z O o 52-6 = nY.D� mm �T 75cd z co �m CLG. w > co D co 0 O _ w o w B 6" ABOVE PASS o >> U) ~THRU COUNTER Y > 0 S.S. PREP a0 TABLE 72"X30" S1 -6 [koEOLR 75cd 48"X30" SPRAY CLG. WASH SINK WITH GRINDER 36" WIDE HAND WASH 36" DEEP SINK DISHWASHER O 60 AMP BRK 3P o 0 O O O UP 1.13 A u EOLR F EOLR T M 2 \ 1.14 A / STORAGE S1-1 TO 75cd BPS CLG. 96"X36" TABLE MEETING AREA D 1.8 2 ELEVATOR TO D FACP F S2-7 P 1.12 75cd FAA P D P,S TO FACP C R 1.9 PRIMARY ELEVATOR RECALL D,P C R 1.10 ALTERNATE ELEVATOR RECALL D,P C R 1.11 FIRE HAT WARNING LIGHTS F] 1.7 MEETING AREA sly WOMEN S2-5 115cd WP LEVEL ONE FIRE ALARM SYSTEM PLAN 1/411= 1' O" i SCALE: 1 /4" = 1 ' -0" S2-4 75cd CLG. TO BPS S2-1 75cd CLG. GFI 0 `� S2-2 75cd CLG. STORAGE POWER COMPANY TRANS ELECTRICAL 1 2 C I MECHANICAL 7p ROOM 1.I 1.4 2 SI C I R 11.3 D AHU-1 2 R 1,5 R6 N AH SUSPENDED FROM FILING WITH PAN BELOW U =1] a S2-3 75cd a CLG. 1.6 0 STORAGE a SOUND OVERRIDE RELAY BPS FACP TO -A-0 FACP [e, FIRE ALARM SYSTEM CABLE LEGEND MARK DESCRIPTION PURPOSE A GENESIS SERIES 4506 2 COND. 18AWG FPLP INITIATION CIRCUIT B GENESIS SERIES 4513 2 COND. 14AWG FPLP NOTIFICATION CIRCUIT D GENESIS SERIES 4506 2 COND. 18AWG FPLP ADDRESSABLE SIGNALING LUNE CIRCUIT P GENESIS SERIES 4513 2 COND. 14AWG FPLP 24VDC POWER CIRCUIT R GENESIS SERIES 4506 (2) 2 COND. 18AWG FPLP DUCT DETECTOR REMOTE TEST SWITCH S GENESIS SERIES 4506 2 COND. 18AWG FPLP SERIAL LINE CKT. TO ANNUCIATOR FPLP DENOTES FIRE POWER LIMITED PLENUM CABLE FIRE ALARM SYSTEM NAC CIRCUITS VOLTAGE DROP CALCULATIONS Faternal larder Of Eagles Zephyrhllls Pasco County FL BPS rip Circuit Circuit Circuit Circuit draw each #1 #2 #3 #4 Level One Level One Level Two Spare North South Device Type 1 LHS3 75cd Wall Mount Horn Strobe 0.105 0 1 0 0 2 ASWP-2475W-FR 115cd W.P. Wall Horn_ Strobe 0.173 0 1 1 0 3 y LHSC3 75cd Ceiling Mount Horn Strobe 0.169 4 4 7 0 4 LHSC3 95cd Ceiling Mount Horn Strobe 0.267 0 0 0 0 5 ASWP-2475C-FR 115cd W.P. Ceiling Horn Strobe 0.173 2 0 0 0 6 LST3 75cd Wall Mount Visual 0.100 0 0 0 0 7 LSTC3 75cd Ceiling Mount Visual 0.155 0 1 1 0_ 8 0.000 0 0 0 0 Q . 0.000 0 0 0 0. 0 _. 0_000 0 0_ 0 0 a 0.000 o o Q PER CIRCUIT DRAW 1 1 1.022 1.109 1.511 0.000 TOTAL AMPS ON POWER SUPPLY 3.642 260 1.511 0.000 0.000 VOLTAGE DROP CALCULATIONS Ckt. #1 Ckt. #2 AMP LOAD 1.022 1.109 DISTANCE FROM SOURCE TO EOL 300 VDROP 250 VDROP WIRE GUAGE 14 1.370 1>4 1.239 CIRCULAR MIL 4110 USABLE 4110 USABLE VOLTAGE DROP PERCENTAGE 6.71%0 19.030 6.07% 19.161 Ckt. #3 Ckt. #4 AMP LOAD 1.511 0 _ DISTANCE 360 VDROP - _ 0 VDROP WIRE GUAGE. 14 2.430 14 0.000 CIRCULAR MIL 4110 USABLE 4110 USABLE VOLTAGE DROP PERCENTAGE 11.91°l0 17.970 0.00% 20.400 NOTE: BATTERY CALCS DONE WITH CIRCULAR MIL METHOD VARIABLES AMP LOAD IS THE CURRENT DRAWN FROM A NAC CIRCUIT - IN AMPS 'DISTANCE - THE DISTANCE FROM SOURCE TO LOAD - IN FEET WIRE GUAGE - SEE CHART BELOW CIRCULAR MIL -- IS THE CROSS SECTIONAL AREA OF THE WIRE GUAGE CHOSEN ;VOLTAGE DROP PERCENTAGE -PERCENT OF VOLTAGE LOST VDROP - THE ACTUAL NUMBER OF VOLTS DROPPED ON CIRCUIT USABLE - VOLTAGE I LEFT AFTER DROP VOLTAGE IS SUBTRACTED FROM M SOURCE WIRE SIZE (AWG) - f 12 14 1 16 I 18 I 20 CIRCULAR MILS (C.M.) 6530 4110 1 25800 1620 1020 COPRER RESISTANCE IS 10.8 OHM PER LM ., ,. EN ., e o 53600 .0. .� fi, EC/ P, �. /gypNA �- 12/04/2019 P.E. STAMP ml Ld Ld m co CD LO LO Ln CO CO LO � I co �--I rr ll di IV �I O O �-� cr) O (� c' J O (D I -I 1 > CD cc (O 00 cz W r-i I W co U) 0 E-� W �_ O C) O 00 0 Q N Lo (" w CO co Co O 4.1 00 O W a O f� O LO CO � E- W z O � O O Pq W O W � W Q � � � O a � � N E O Q4 4-1 E- el DRAWN BY: DQDD APPROVED BY: DATE: 11 /21 /19 SCALE: AS INDICATED PROJECT NO: r LEVEL ONE FLR. PLAN NAC CKTS. VOLTAGE DROP CALCULATIONS It& 6 Fa? 0 U) LLJ ry LLJ