HomeMy WebLinkAbout36153 Shady Bluff Lp Lt 1035'-O" FLOOR PLAN A NOT TO SCALE LINTEL SCHEDULE LINTEL SIZE REINF L1 8"x 16" 1-#5 T&B L2 8 x 24 -1-#5 T&B L3 8' x 32 1-#5 T&B *PRECAST LINTEL, (1) #5 REBAR IF OVER 6' NO REBAR REQ'D IF LESS THAN 6' WASHER & DRYER LOCATIONS REMAIN THE SAME REGARDLESS OF GARAGE HANDING. WASHER ON LEFT, AND DRYER ON RIGHT L1 K.O. COARSE ALL CELLS, K.O. & P.C. LINTEL FILLED 0 A w/3000 PSI CONC P.C. LINTEL LIVING AREA 1485 LANAI 108 GARAGE 387 TOTAL AREA 1980 L3 L2 K.O. COARSE K.O. COARSE ALL CELLS, K.O. & P.C. LINTEL FILLED ALL CELLS, K.O. & w/3000 PSI CONIC P.C. LINTEL FILLED !: w/3000 PSI CONC !: P.C. LINTEL P.C. LINTEL A/C FO UNDA TION PLAN --� F 114 -1' 3 TAB FIBERGLASS SHINGLES ON 15# FELT, 1 /2' CDX SHEATHING OR 7/16' O.S.B. — 8d RING SHANK NAILS 0 6' O.C. SIMPSON HETA20 0 EA END OF EA TRUSS (OR EQUAL) �< 2x SUB FASCIA J_/ VINYL SOFFIT PRECAST CONC. LINTEL-` w/1 - #5 CONT. 0 SPANS 6'-0" AND GREATER ALUM. WINDOW - (SIZE PER PLAN) PRE -CAST CONC. SILL CEMENTITTOUS FINISH INSTALLE IN COMPLIANCE W/ ASTM 926 AND ASTM 1063 #5 BAR DOWEL w/10" STD. HOOK (LAP MIN. 25" w/ VERT. REINF. BAR) —� ROOF PITCH PER ELEVATION -ENGINEERED TRUSS OTHERS) R-30 BAT. INSUL. W/ BAFFELS (SEE ENERGY CALC.) " GYP CEILING BIRD LINTEL BLOCK w/1 #5 CONT. FILLED w/3000 PSI CONC. 1 /2' GYP. BIRD. ® WALLS ON 1x2 PT FURRING STRIPS ® 24' o.c. w/R15 FOAM INJECTED INSUL. 3 1 /2' CONC. SLAB w/6x6 #10 W.W.M. OR FIBERMESH EXISTING UNDISTURBED OR ENGINEERED SOIL U co (2)-#5 CONT. t•_4" 3 CLi TYPICAL CMU WALL SECTION NOT TO SCALE EXISTING UNDISTURBED OR 4" THICK REINF. CONC. ENGINEERED SOIL •" SLAB W/ 2500 P.S.I. 7IFzll::=llAllrl :.• I FIBERMESH 12X18 BELL • r '� I FOOTER. (2)-#5 REBAR 12' 3' C R AL T MONO FO 0 TER DETAIL t� 4' THICK REINF_ CONC. SLAB 2500 P.S.1. W/ FIBERMESH OX12 STEP-DOWN FOOTER NO REBAR REQUIRED) STEP—DOWN FOOTER DETAIL NOT TO SCALE 4' THICK REINF. CONC. SLAB W 2500 P.S.I. FIBERMESH 8x8 M 0 FOOTER (NO REBAR ROD.) =Cll THICKENED EDGE l A+ NOT TO SCALE 1 co_^ s •o ALL WpRK SHALL T `�'�AILI�rp CODES, CpMPLYWIT COD_P, NATIO]v FLORIDAL CjTyoFZEP ALELECTRI CB�I4ING HYRHILLS >aT�PEAAD 12 5 SIDING NVEN -Kim REAR ELEVATION 114" = 1 ' LEFT ELE VA TION 114 4" BAND BAND CONTINUOUS RIDGE VENT FIELD BRACING is not the responsibility of the truss fabricator, truss designer, or plate manufacturer. Persons erecting trusses are cautioned to seek professional advice regarding temporary and erection bracing which is always required to prevent toppling and dominoing during erection, and permanent bracing which may be required in specific applications. Trusses shall be erected and fastened in a straight and plumb position, Where no direct top chord sheathing is applied, trusses must be braced at 24' on center maximum. Where no direct bottom chord sheathing is applied, trusses must be braced at 104' on center maximum. Trusses must be handled with extreme care during erection to prevent damage or personal injury. Refer to truss engineering for connection and bracing requirements, These calculations are supplied in order for the ENGINEER OF RECORD to adequately provide for connection and integration of the roof assembly to the supporting structure. Designers of supporting connections are SOLELY responsible for the integrity of their product. Trusses remain our property until paid for in full. Truss layouts and engineering may not be reproduced in part or in full under any circumstances. APPROVED TRUSS ANCHOR BY BUILDER PLUMB CUT OVERHANG HEEL HEIGHT = 2x4 STD 5 12 BOTTOM = 2x4 MIN TOP = 2x4 MIN _ • -.ad 2.5 12 L� 1'-0' 1 TRUSS END DETAIL 12 5 SPECIAL NOTE ANY PARTY WHO CUTS OR DAMAGES A TRUSS SHALL BE RESPONSIBLE FOR THE ENGINEERING DESIGN AND COST OF THE REQUIRED REPAIR. WARNING ff A SPREADER BAR IS REQUIRED TO PROPERLY SET TRUSSES ON THIS BUILDING. REFER TO HIB 91 SUMMARY SHEET OR CALL (941)665-9001 FOR INFORMATION. TRUSS BRACING 1) THE TOP CHORD PERMANENT BRACING IN THE FORM OF SHEATHING, OR PURUNS FOR A PIGGYBACK CONDITION. 2) BOTTOM CHORD PERMANENT BRACING IN THE FORM OF PURUNS ONLY IN AREAS WHERE THE DRYWALL WILL NEVER BE ATTACHED. THIS CAN OCCUR WHEN A BOTTOM CHORD IS CONCEALED BY A 'FILLER" BOTTOM CHORD SECTION OR "FALSE' BOTTOM 3) ALL PERMANENT WEB BRACING AS SPECIFIED BY THE INDIVIDUAL TRUSS DESIGN DRAWING. HMCAFF CHApf 4L - HUS 26 (SIMPSON) - HGUS28-2 (SIMPSON) A L - HGUS28-3 (SIMPSON) STRAP / NAILING SCHD QTY STRAP MFG. NAILING — HUS 26-2 SIMPSON (4) 12d — RT — 18 USP (4) 1Od — TA — 20 USP (8) 1Od REFER TO ENG PACK FOR CONNECTION — CJ3 0 i CJ1 U U 1 —0 44 2'_0" TYPICAL 5' SETBACK CORNERSET LABELING AND SPACING ROOF DET REFER TO ENG PACK FOR CONNECTION — CJ5 CJ3 LO U II II 1'-0 2'-0" TYPICAL 7' SETBACK CORNERSE-r LABELING AND SPACING AIL 114 = 1' CG C1 C1 AG A A A Al Al Al Al Al Al A2 A4 A6 A8 A10 Al2 A14 A15 131 B2 B3 B4 B5 D1 CJ5 CJ3 CJl 35' 26' 9' N N N N . . . . _. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...... ..................................----..----.-----.--... ------------- - - - -- N. . . . . . . . . . . . . . . . . . . . . . . . . . ............................. ------------------------------ . . . . . . . . . . . . . . . . . . . . . . . . - ................ . . . CV . . . . . . . . . . . . . . . . . . . . . . . - - - - - - DD- SPACE--- ------------------- --------------------------- - - - - -- N. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . :. . . . . . . . . . . . . . . . . . . . . . . -- -- ............... HUS26 HUS26 \LJ U HUS2p6 I HUS26 I 00 w CJ5 o CJ3 CJ1 roaDo 0o u� ro � —� —� —� v)-7 U U U W LUS24 \CJ5S LUS24 J3S or .. Cl) uO r` r` rl- r- In ch ., y U U U W W W W U U U 20' 12' 32' TRUSS ANCHORS TR US S LAYOUT A 1 /4 " = 1 ' TRUSS TO BILK WALL CALCULATED FOR WORST CASE SCENERIO (1) USP TA 20 (OR EQUAL) EACH END EACH TRUSS CONNECTED w 8 10d NAILS 0 EACH STRAP FOR (1) PLY OR HIP GIRDER, USE (2) US 20 EACH END FOR (2/3) PLY GIRDER USE (2) USP TA20 EACH END FOR GABLE END TRUSS, USE (1) USP TA20 OR EQUAL UNLESS NOTED OTHERWISE EJ2 M CJl v N RIGHT ELEVATION 1/4" = 9' ELEC-ripirl'IC PLANTO BUILDING 2" C 200 A 10 MC9 ELECTRICAL NOTES SMOKE DETECTORS LOCATED ON WALL 12" TO BOTTOM OF BOX OUT. VANITY LIGHTS 80" TO CENTER OF BOX OUT. FRONT DOOR GFI 4" OFF SLAB CENTER (SEE METER PLAN FOR LOCATION). TV AND PHONE LOCATIONS PER COLOR SHEET, OTHER ELECTRICAL OPTIONS PER COLOR SHEET. DISHWASHER, DISPOSAL OUTLETS UNDER SINK. MICROWAVE PRE -WIRE. U/G FROM NOTES UTILITY CO. 8KW & 3 1/2 TON - 6/2 ROMEX RISER T.S. LIVING AREA 1485 LANAI 10 GARAGE 387 TOTAL AREA 1980 ELEC LEGEND SYM. DESCRIPTION SINGLE POLE SWITCH THREE WAY SWITCH 4 FOUR WAY SWITCH 110V RECP. 9 110V DUPLEX RECP. & 220V RECP. �Fl 110V GROUND FAULT INTERUPT HALF SWITCHED DUPLEX RECP. LIGHT FIXTURE ® RECESSED LIGHT FIXTURE JUNCTION BOX EXHAUST FAN ® EXH. FAN/LIGHT COMBINATION TELEPHONE JACK / CAT 5 SD SMOKE DETECTOR S�C COMBO SMOKE/CARBON MONOXIDE DET. O TELEVISION OUTLET 4))) SPEAKER WIRE OT THERMOSTAT A/C HVA C PLAN 114 " _ > ' EQUIPMENT BY (SEE ENERGY CALL) COND SEE ENERGY CALC) A/H SEE ENERGY CALC) HEATER 8KW) SEER 14 HSPF 7.5 DUCTBOARD R-6.5 FLEX R-6 BOOTS R 6 TAPE FASSON UL 181 CODE FRAME ROUGH OPENING CODE FRAME ROUGH OPENING 12 1858X251 2 22 361 2X251 2 13 1858X3778 23 361 2X3778 14 1858X501 8 24 361 2X501 8 245 36 1 2 X 55 1 2 15 18 5/8 X 62 1 2 25 36 1 2 X 62 1 2 EGRESS 16 1858X71 1 2 26 361 2X71 1 2EGRESS 17 18 5/8 X 83 1 2 27 36 1 2 X 83 1 2EGRESS 1/2 32 26X251 2 32 5258X251 2 1/2 33 26X3778 33 5258X3778 1/2 34 26X501 8 34 5258X501 8 345 52 5/8 X 55 1 2 1 2 35 26 X 62 1 2 35 52 5/8 X 62 1 2 EGRESS 1/2 36 26X71 78 36 5258X71 1 2EGRESS 12 3 2 _X 83 1 37 2 5/8 X 83 1. 2 EGRESS 2024 24 X 28 3050 36 X 60 2030 24 X 36 3060 36 X 72 EGRESS 2040 24 X 48 3424 40 X 28 2050 24 X 60 3430 40 X 36 2060 24 X 72 3440 40 X 48 2424 28 X 28 3450 40 X 60 2430 28 X 36 3460 40 X 72 EGRESS 2440 28 X 48 3824 44 X 28 2450 28 X 60 3830 44 X 36 2460 28 X 72 3840 44 X 48 2824 32 X 28 3850 44 X 60 2830 32 X 36 3860 44 X 72 EGRESS 2840 32 X 48 4024 48 X 28 2850 32 X 60 4030 48 X 36 2860 32 X 72 4040 48 X 48 3024 36 X 28 4050 48 X 60 3030 36 X 36 4060 48 X 72 EGRESS 3040 36 X 48 GENERAL NOTES SUPPLEMENTAL NOTES A FOUNDATION SURVEY SHALL BE PERFORMED AND A COPY OF THE SURVEY SHALL BE ON THE SITE FOR THE BUILDING INSPECTORS USE. OR, ALL PROPERTY MARKERS SHALL BE EXPOSED AND A STRING STRETCHED FROM MARKER TO MARKER TO VERIFY REQUIRED SETBACKS. ALL PLUMBING, ELECTRICAL AND MECHANICAL ROUGH -INS MUST BE COMPLETE, INSPECTED AND APPROVED BEFORE REQUESTING THE FRAMING INSPECTION. A PERMANENT SIGN WHICH IDENTIFIES THE TERMITE TREATMENT PROVIDER AND NEED FOR RE -INSPECTION AND TREATMENT CONTRACT RENEWAL SHALL BE PROVIDED. THE SIGN SHALL BE POSTED NEAR THE WATER HEATER OR ELECTRIC PANEL. CONDENSATE AND ROOF DOWNSPOUTS SHALL DISCHARGE AT LEAST 1'-0" AWAY FROM BUILDING SIDE WALLS. IRRIGATION/ SPRINKLER SYSTEMS INCLUDING ALL RISERS AND SPRAY HEADS SHALL NOT BE INSTALLED WITHIN 1'-0" OF THE BUILDING SIDE WALLS. TO PROVIDE FOR INSPECTION FOR TERMITE INFESTATION, BETWEEN WALL COVERING AND FINAL EARTH GRADE SHALL NOT BE LESS THAN 6 INCHES. EXCEPTION: PAINT OR DECORATIVE CEMENTITIOUS FINISH LESS THAN 5/8" THICK ADHERED DIRECTLY TO THE FOUNDATION WALL. INITIAL TREATMENT SHALL BE DONE AFTER ALL EXCAVATION AND BACKFILL IS COMPLETE. SOIL DISTURBED AFTER THE INITIAL TREATMENT SHALL BE RETREATED INCLUDING SPACES BOXED OR FORMED. BOXED AREAS IN CONCRETE FLOORS FOR SUBSEQUENT INSTALLATION OF TRAPS, ETC., SHALL BE MADE WITH PERMANENT METAL OR PLASTIC FORM& PERMANENT FORMS MUST BE OF A SIZE AND DEPTH THAT WILL ELIMINATE THE DISTURBANCE OF SOIL AFTER THE INITIAL TREATMENT. MINIMUM 6 MIL VAPOR RETARDER MUST BE INSTALLED TO PROTECT AGAINST RAINFALL DILUTION. IF RAINFALL OCCURS BEFORE VAPOR RETARDER PLACEMENT, RETREATMENT IS REQUIRED. CONCRETE OVERPOUR AND MORTAR ALONG THE FOUNDATION PERIMETER MUST BE REMOVED BEFORE EXTERIOR SOIL TREATMENT. SOIL TREATMENT MUST BE APPLIED UNDER ALL EXTERIOR CONCRETE OR GRADE WITHIN 1'-0" OF THE STRUCTURE SIDEWALLS. AN EXTERIOR VERTICAL CHEMICAL BARRIER MUST BE INSTALLED AFTER CONSTRUCTION IS COMPLETE INCLUDING LANDSCAPING AND IRRIGATION. ANY SOIL DISTURBED AFTER THE VERTICAL BARRIER IS APPLIED, SHALL BE RETREATED. ALL BUILDINGS ARE REQUIRED TO HAVE PRE -CONSTRUCTION TREATMENT. A CERTIFICATE OF COMPLIANCE MUST BE ISSUED TO THE BUILDING DEPT BY A LICENSED PEST CONTROL COMPANY BEFORE A CERTIFICATE OF OCCUPANCY WILL BE ISSUED. THE CERTIFICATE OF COMPLIANCE SHALL STATE: "THE BUILDING HAS RECEIVED A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN TERMITES. THE TREATMENT IS IN ACCORDANCE WITH THE RULES & LAWS OF THE FLORIDA DEPT OF AGRICULTURE AND CONSUMER SERVICES." AFTER ALL WORK IS COMPLETED, LOOSE WOOD AND FILL MUST BE REMOVED FROM BELOW AND WITHIN 1'-0" OF THE BUILDING. THIS INCLUDES ALL GRADE STAKES, TUB TRAP BOXES, FORMS, SHORING OR OTHER CELLULOSE CONTAINING MATERIAL. NO WOOD, VEGETATION, STUMPS, CARDBOARD, TRASH, ETC., SHALL BE BURIED WITHIN 15'-0" OF ANY BUILDING OR PROPOSED BUILDING. MASONRY GENERAL NOTES STRUCTURAL DESIGN CRITERIA 1. MASONRY CONSTRUCTION SHALL CONFORM TO ACI STANDARD BUILDING CODE 1. FBC / FBCR 5th EDITION 2014 REQUIRMENTS FOR CONCRETE MASONRY STRUCTURES (ACI 530-11). 2. ASCE/SEI 7-10 CODE (140 mph) 2. CONCRETE BLKS SHALL CONFORM TO ASTM C 90 (28 DAY STRENGTH=2000 3. STRUCTURE RISK CATEGORY = II PSI, FM=1350 PSI) LAID IN RUNNING BOND. 4. ENVELOPE PROCEDURE FOR LOW RISE BUILDINGS 3. MORTAR SHALL BE TYPE S OR M. 5. EXPOSURE FACTOR = B 4. WHERE SHOWN, CELLS OF MASONRY BLOCK SHALL BE FILLED WITH CONCRETE 6. INTERNAL PRESSURE COEFFICIENT = t0.18 WITH A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI AT 28 DAYS & 1-#5, 7. 2nd FL LOADS: LIVE LOAD-40 PSF/DEAD LOAD-10 PSF VERTICAL. 8. ROOF LOADS: LIVE LOAD-20 PSF/DEAD LOAD-10 PSF 5. PROVIDE KNOCK -OUT IN CONCRETE MASONRY UNIT AT BASE OF EACH FILLED 9. COMPONENT & CLADDING WALL PRESSURE= (+35.3) (-47.2) PSF (MAX) CELL TO ALLOW VISUAL VERIFICATION OF COMPLETE GROUT PENETRATION. ROOFING / FLASHING DRAINAGE ROOF DEAD LOAD - 7# P.S.F. ROOF LIVE LOAD - 20# P.S.F. ALL ROOF PROVIDE AN ALTERNATE METHOD OF DIVERTING WATER AWAY FROM THE COMPONENTS ARE PRE-ENGINEERED TRUSSES. ENG. WILL BE SUPPLIED TO FOUNDATION, WHICH WAS NEEDED IN SITUATIONS LIKE "ZERO -LOT -LINE" FIELD INSPECTOR AT TIME OF FRAMING INSPECTION (SEE TRUSS LAYOUT CIRCUMSTANCES. THE ALTERNATIVE IS TO PROVIDE A MINIMUM OF 5% PROVIDED.) ROOF SHEATHING NAILING SCHEDULE FOR 7/16" OSB ROOF SLOPE AWAY FROM THE FOUNDATION. DECK, USE 8d RING SHANK NAILS, SPACE 6" O.C. AT EDGES & 6" O.C. STEMWALL FOOTING IN FIELDS. GAF SENTINEL/TIMBERLINE/CERTAINTEED FIBERGLASS SHINGLES STEMWALL FOOTING AS SHOWN ON WALL SECTION UP TO 36" HIGH CAN BE SECURE w/(5) NAILS PER SHINGLE ON UNDERLAYMENT OVER 7/16" OSB USED WITH UNBALANCED FILL. UNBALANCED FILL GREATER THAN 36" SHALL BE ROOF DECK. PRODUCT MEETS ASTM D3462, D3161 F, D7158 G AND UL TEMPORARILY SUPPORTED DURING BACKFILLING & CONCRETE SLAB PLACEMENT 997 FOR WIND SPEEDS UP TO 140 MPH. FLASH ALL VALLEYS W/ MIN. BY CONTRACTOR. THE MAXIMUM STEMWALL HEIGHT SHALL BE 10'-0" 16"x26GA VALLEY METAL PLACED OVER UNDERLAYMENT NAILED 12" o.c. WINDOWS 0 EDGES. WHERE WALLS MEET ROOF LINE, ALL FLASHING SHALL CONFORM ALL WINDOWS TESTED AND APPROVED IN ACCORDANCE WITH ANSI/AMMA/NWWDA TO FBCREQUIREMENTS.M T 101/IS2 STANDARD AND LABELED AS SUCH. WINDOWS TO BE INSTALLED PER ASTMRLA57NTS INSTALLEDLCONFORM ASTM AND D226,MANUFACTURERS ' REQUIREMENTS FOR APPLICABLE DESIGN PRESSURE. WINDOWS MANUFACTURERS SPECS. IN MASONRY WALLS SHALL BE ANCHORED THROUGH 1x BUCK INTO MASONRY. FRAMED WALLS WINDOWS IN WOOD FRAMED WALLS MAY BE INSTALLED WITHOUT BUCKS. ALL ALL INTERIOR NON -BEARING WALLS MEET R6021.3.1. LUMBER TO BE MULLIONS SHALL CONFORM TO FBC REQUIREMENTS OF 1.5x THE DESIGN LOAD. STD SPF OR HIGHER GRADE. THE LOWEST PART OF THE CLEAR OPENING OF THE WINDOW TO BE A MIN. OF 24" ABOVE FINISHED FLOOR WHERE THE OPENING OF THE OPERABLE WINDOW ALL INTERIOR FRAMED BEARING WALLS TO BE #2 SPF. IS LOCATED MORE THAN 72" ABOVE FINISHED GRADE OR THE SURFACE BELOW. ALL WOOD BEARING HEADERS TO BE #2 SYP (SIZES AS INDICATED ON PLAN) EXCEPT FOR WINDOWS WHOSE OPENINGS WONT ALLOW A 4" DIA. SPHERE TO FRAMED GARAGE WALLS TO HAVE MIN 1/2" GYPSUM BIRD (IF AREA ABOVE PASS AND OPENINGS THAT ARE PROVIDED WITH GUARDS COMPLY WITH ASTM F GARAGE IS HABITABLE, USE 5/8" TYPE X GYPSUM BRD ON CLNG). 2006 OR ASTM F 2090. TRUSS ANCHORS GARAGE DOOR TRUSS TO BILK WALL CALCULATED FOR WORST CASE SCENERIO (1) SIMPSON GARAGE DOOR TO BE 140 MPH RATED (MIN +18.3/-20.4 PSF DWP) INSTALL HETA20 (OR EQUAL) EACH END EACH TRUSS CONNECTED w/(9) 10d NAILS 0 2x6 PT EA SIDE w/(3) 1/2"x8" "J" BOLTS w/2" WASHERS SPACED EQUALLY EACH STRAP FOR (1) PLY OR HIP GIRDER. USE (2) SIMPSON HHETA20 EACH END ALONG LEGNTH EMBEDED INTO POURED CELLS (OPTION: MAY USE 1/2"x6" FOR (2/3) PLY GIRDER. USE (2) SIMPSON HHETA20 EACH END FOR GABLE END WEDGE ANCHORS W/2" WASHERS) ANCHOR 2x6 PT ABOVE DOOR TO LINTEL W/ TRUSS, USE (1) SIMPSON HETA20 OR EQUAL UNLESS NOTED OTHERWISE WEDGE ANCHORS, CONCRETE SCREWS OR .145" 0 P.D.F.'s A PERMANENT LABEL IS REQUIRED AND THE INSTALLATION INSTRUCTIONS ARE REQUIRED TO BE MISPLACED TRUSS STRAP IN THE CASE WHERE TRUSS STRAP IS MISSING THE PROVIDED AND AVAILABLE ON THE JOB SITE AS WELL. THIS ADDITION ENABLES FOLLOWING METHOD MAY BE USED AS AN ALTERNATE. SUBSTITUTE A SIMPSON ENABLES ASSURANCE OF COMPLIANCE MTS18 OR HUGHES RT18 TW (OR EQUIVALENT) FOR EACH HETA20-18 MISSED. EXTERIOR PRE -HUNG DOORS CONNECT TRAP TO BOND BEAM WITH (3) 3/16" X 1 3/4" HEX HEAD TAPCONS. THIS SUBSTITUTION IS GOOD FOR A MAXIMUM UPLIFT OF 1,000# PER STRAP. 1x DOOR BUCK (IF READ) TO BE ATTACHED TO MASONRY WALL w/1 1/2 x.106 ELECTRICAL NOTES WIRE COLLATED NAILS 0 4"O.C. 2x DOOR BUCK (IF READ) TO BE ATTACHED TO MASONRY WALL w/2 1/2x.106 WIRE COLLATED NAILS ® 4" O.C. SECURE PRE- ELECTRICAL SYSTEMS AS INDICATED ON THESE PLANS ARE SCHEMATIC ONLY HUNG DOOR UNIT PRE MFG SPECS. AND DESIGNS SHALL BE PREPARED IN ACCORDANCE WITH THE NATIONAL ELECTRIC CODE (2011 NEC). ATTIC ACCESS SMOKE DIET. LOCATED ON WALL 12" TO BOT. OF BOX OUT. VANITY LIGHTS ATTIC ACCESS SHALL COMPLY WITH SECTION R807.1 WITH A MIN. OPENING OF 80" TO CENTER OF BOX OUT. FRONT DOOR GFI 4" OFF SLAB CENTER (SEE PLAN FOR LOC.) TV & PHONE LOCATIONS PER COLOR SHEET. OTHER 22"00". ELECTRICAL OPTIONS PER COLOR SHEET. DISHWASHER, DISPOSAL OUTLETS EXTERIOR SIDING UNDER SINK. MICROWAVE PRE -WIRE. 1OKW & 5 TON - 6/2 ROMEX. FRONT MIN 3/8" LP SMARTPANEL OR 7 OSB SHEATHING NAIL w CC 6" O.C.DOOR 16 / " 8d / GFI 4" OFF SLAB CENTER (SEE PLAN FOR LOCATION) ALL ELECTRICAL AT SLIDING GLASS DOOR TO BE ON RIGHT HAND SIDE EDGES & 6" O.C. IN FIELDS REGUARDLESS OF GARAGE HANDING. MISPLACED WALL RIENFORCING NOTE USE OF AFCI RECEPTACLES AND TAMPER RESISTANT RECEPTACLES IN THE CASE WHERE A FOOTING DOWEL IS MISPLACED THE FOLLOWING LATH CORRECTION IS ACCEPTABLE: ADD A DOWNPOUR w/(1) #5 VERT REINFORCING ALL ATTACHMENTS FOR SECURING WIRE LATH SHALL BE SPACED NOT IN THE CORRECT ORIGINAL LOCATION. THE BAR SHALL BE 11ED INTO THE BOND MORE THAN 6" APART, AND SIDE LAPS SHALL BE SECURED TO SUPPORTS BEAM w/ A MIN. HOOK OF 10". IF THE NEW DOWEL LOCATION IS MORE THAN 8" AND BE 11ED BETWEEN SUPPORTS NOT TO EXCEED 9". ALL METAL LATH OFFSET FROM ORIGINAL LOCATION THE BOTTOM OF THE BAR SHALL HAVE A SHALL BE LAPPED 1" MIN. METAL WIRE LATH SHALL BE ATTACHED TO #5x24" LONG DOWEL DRILLED 4" INTO THE CONCRETE SLAB & SET IN SIMPSON VERTICAL WOOD SUPPORTS WITH THE EQUIVALENT OF 4d GALVANIZED SET EPDXY. IF LESS THAN 8" NO EPDXY NEEDED. CELL SHALL BE FILLED NAILS WITH A PENETRATION OF 3/4 AND BENT OVER AT LEAST 3 w/ A MIN. 2500 PSI CONCRETE. STRANDS OF LATH. A BOND BREAK SHALL BE PROVIDED BETWEEN THE WATER- RESISTIVE BARRIER & THE CEMENT PLASTER CONSISTING OF ONE FLASHING, SEALANTS, AND WEATHERSTRIPPING OF THE FOLLOWING: TWO LAYERS OF AN APPRVD WATER-RESISTANT BARRIER MATERIAL OR ONE LAYER OF AND APPVD WATER-RESISTANT ALL FENESTRATIONS PRODUCTS TO BE SEALED AT THE JUNCTURE OF THE BARRIER OVER AN APPRVD PLASTIC HOUSE WRAP SHALL BE UNDER BUILDING WALL WITH A SEALANT COMPLYING WITH AAMA 800 AND ASTM C WIRE LATH. 920, ASTM C 1281, AA812, OR OTHER APPROVED STANDARD. FFNFSTRATInN LOAD -BEARING PRESSURE CLASS OF MATERIAL (LBS< PER sQ/FT) CRYSTALLINE BEDROCK 12,000 SEDIMENTARY AND FOLIATED ROCK 4,000 SANDY GRAVEL AND/OR GRAVEL 3,000 (GW AND GP) SAND, SILTY SAND, CLAYEY SAND, 2,000 SILTY GRAVEL AND CLAYEY GRAVEL (SW,SP,SM,SC,GM AND GC) CLAY, SANDY CLAY, SILTY CLAY, 1,500 CLAYEY SILT, SILT AND SANDY SILT (CL,ML,MH AND CH) JUNCTURE OF EXTERIOR PLASTER AND ANY FENESTRATION PRODUCT IS REQD TO BE SEALED WITH A SEALANT COMPLYING WITH SECTION 612.12 PLUMBING ON MONO SLABS THE SEWER AND HVAC CONDENSATE LINE WILL GO UNDER THE FOOTER, ON A STEM WALL THE LINES WILL GO THROUGH THE BLOCK FOR THE LINE THAT PASSES THROUGH IT WILL BE SLEEVED WITH A PIPE TWICE THE SIZE OF IT 3" WILL BE SLEEVED WITH 6" AND 3/4" WILL BE SLEEVED WITH 1 1 /2". RECIRCULATION OF AIR M1507.2 EXHAUSET AIR FROM BATHROOMS AND TOILET ROOMS SHALL NOT BE RECIRCULATED WITHIN A RESIDENCE OR TO ANOTHER DWELLING UNIT AND SHALL BE EXHAUSTED DIRECTLY TO THE OUTDOORS. APPLIANCE PROTECTION M1307.3.1 ALL APPLIANCES SHALL BE PROTECTED FROM IMPACT BY AN APPROVED BARRIER SINGLE DOOR FL# CODE VERSION STATUS MANUFACTURER CATEGORY SUB CATEGORY PRODUCT MODEL # OR NAME PRODUCT DESCRIPTION BOOR BOOR W:R I NON IMPAG BOORS BOORS - --- DOOR 11345-R2 2014 APPRVD CROFT LLC WINDOWS FIXED 4400 SERIES ALUM. PICTURE WINDOW 15585.1 2014 APPRVD CROFT LLC WINDOWS SINGLE HUNG 96 SERIES SINGLE HUNG ALUMINUM SH WINDOW 16079.1 2014 APPRVD CROFT LLC EXTERIOR DOORS SLIDING EXT DOOR ASSEMBLIES 3000 SERIES SLIDING GLASS DOOR 17680.2 2014 APPRVD UNITED STEEL PRODUCTS COMPANY STRUCTURAL COMPONENTS WOOD CONNECTOR ANCHORS 10655-R3 2014 APPRVD SIMPSON STONG-TIE COMPANY STRUCTURAL COMPONENTS WOOD CONNECTOR ANCHORS 1774--134 2014 APPRVQ COMMERCIAL CONC PRODUCTS, INC. STRUCTURAL COMPONENTS PRECAST/PRE- STRESSED LINTELS 8" &12" LINTELS 4904-R7 2014 APPRVD MASONITE INTERNATIONAL EXTERIOR DOORS SWINGING EXT DOOR ASSEMBLIES STEEL DOOR WITH OR WITHOUT SIDELITES 444.1 2014 APPRVD CERTAINTEED CORPORATION ROOFING ASPHALT SHINGLES 3-TAB / ARCH LAMINATED SHINGLE 075-R7 2014 APPRVD FL METAL PRODUCT COMPANY INC ROOFING ROOFING ACCESSORIES RIDGE VENT 219.1-R2 2014 APPRVD TAMCO ROOFING ROOFING ACCESSORIES OFF RIDGE VENT 15279.20 2014 APPRVD CLOPAY BLDG PRODUCTS CO EXTERIOR DOORS SECTIONAL EXT DOOR ASSEMBLIES WINDCODE W4 GARAGE DOOR 13389.1 2014 APPRVD CERTAINTEED CORPORATION PANEL WALLS SOFFITS VINYL SOFFITS 13192 2014 APPRVD Foducts0 Inic Building PANEL WALLS SIDING LAP SIDING 9190-R6 2014 APPRVD LP Building Products PANEL WALLS SIDING SMART PANEL ENG. WOOD EXT PANEL 17194.1 1 2014 1 APPRVDI ROBETEX INC I ROOFING UNDERLAYMENT TECH WRAP SYN. UNDERLAYMENT DOUBLE DOOR SINGLE DOOR W/ SDLT SINGLE DOOR W/(2) SDLTS EXTERIOR PRE -HUNG DOORS SECURE PRE -HUNG DOOR UNIT USE 10 WOOD SCREWS/TAPCONS USE SIMPSON 1/4 X 1 1 /2" MIN NAILON PINS AT THRESHOLD DOOR INSTALATIONIFASTENER PLACEMENT NOT T SCALE ROOF PITCH PER ELEVATION ROOF PITCH PER ELEVATION ---CONNECT BEAM TO TRUSS W/SIMPSON MTS12. U.N.O. ,II, W I TRUSS STRAP PER GENERAL NOTES #2 SYP BEAM (SIZE PER PLAN) STRAP W/(1) SIMPSON HETA20 ISURFACE I PRECAST LINTEL W 1 #N5 BE&TW►EENONTINUOUS COLUMNS W MIN. 8" BEARING SURFACE/ EACH END CAP ALL CELLS THAT FLOOR PLAN INDICATES REBAR SHALL BE CONCRETE FILLED. ALL CELLS THAT FLOOR PLAN INDICATES REBAR SHALL BE CONCRETE FILLED. CMU COLUMN AT FRONT ENTRY PORCH W/#5 VERTICAL. (COLLI N HEIGHT PER ELEVATION) (COLUMN SIZE & REBAR PLACEMENT PER FLOOR PLAN) FOOTING DOWELS: 2-#5 EMBED. 6" MIN. INTO FTG. W/ 90' HOOK PAD PER FOUND PLAN MASONRY COLUMN DETAIL W/UPSET BEAM (ENTRY) NOT TO SCALE HALL BATH ELEVATION MASTER BATH ELEVATION CMU COLUMN AT FRONT ENTRY PORCH W/#5 VERTICAL. (COLU HEIGHT PER ELEVATION) (COLUMN SIZE & REBAR PLACEMENT PER FLOOR PLAN) FOOTING DOWELS: 2-#5 EMBED. 6" MIN. INTO FTG. W/ 90' HOOK i- - '� PAD PER FOUND PLAN MASONRY COLUMN DETAIL W/PRECAST LINTEL NOT TO SCALE KITCHEN ELEVATION #3 26 GA VALLEY METAL (SEE GENERAL NOTES FOR NAIL PATTERN) ROOF DECK W/15# FELT NOTES TYPICAL EACH SIDE VALLEY FLASHING DETAIL SIDING NOT To SCALE METAL FLASHING SHINGLE : 1. ROOF CEMENT ROOF DECK FLASHING DETAIL NOT TO SCALE CIABINET E'LEVA TIONS I ROOF VENTILATION CALCULATIONS FLORIDA BUILDING CODE 2014 SECTION 806.2 - 1 300 TOTAL ATTIC SPACE - 2065.00 NET FREE VENT NEEDED - 495.60 # OF RIDGE VENTS - 3 # OF OFF RIDGE VENTS - NA COMPONENTS FLORIDA SECTION AND CLADDING BUILDING CODE 2014 301.2 140 MPH NO- ZONE EFFECTIVE WIND AREA DESIGN WIND PRESSURE A 4 10 +35.3/-38.2 B 4 20 +33.7/-36.7 C 4 50 +31.6/-34.6 D 4 100 +30.0/-33.0 AA 5 10 +35.3/-47.2 BB 5 20 +33.7/-44.0 CC 1 5 1 50 +31.6/-39.8 DD 1 5 1 3UX '-36.7 TYPICAL EXAMPLES A 1 /2 32, 1 /2 33, 1 /2 34, 22 B 1 /2 35, 1 /2 36, ALL SH 2- SH 32-34, 3-0 DOOR OR LESS C SH 35, 36, 5-0 OR 6-0 SGD 8-0 SGD, 8-0 OHD 16-0 X 7-0 OHD < +22.0/-26.9 KITCHEN ELEVATION #2 /4 » _ 1' CONVENTIONAL VALLEY FRAMING DETAIL GABLE END, COMMON RIDGE BEAM TRUSS OR GIRDER TRUSS - (SEE NOTE 16) VALLEY RAFTERS (24' O.C. MAX) TRUSS TYPICAL (24" 15.Cr POST (SEE CONSTRUCTION SEQUENCE (ALL MATERIAL 32 OR BETTER) TRUSS MUST BE SHEATHED 1. INSTALL BASE TRUSSES. 2. APPLY SHEATHING TO TOP CHORD OF SUPPORTING TRUSSES. IF SHEATHING IS NOT APPLIED. PROVIDE 2x4 PURUNS AT 24" O.C. ON THE TOP CHORD OF THE SUPPORTING TRUSSES UNDER THE VALLEY FRAMING. CONNECT PURLINS TO EACH TRUSS WITH (2) - 16d NAILS. 3. BRACE BOTTOM CHORD AND WEB MEMBERS PER TRUSS DESIGNS. 4. INSTALL 2 x 4 VALLEY PLATES. FASTEN TO EACH SUPPORTING TRUSS WITH (2) 16d NAILS. 5. DEFINE VALLEY RIDGE BY RUNNING A LEVEL STRING FROM THE INTERSECTING RIDGE OF THE (a.) GABLE END. (b.) GIRDER TRUSS OR (c.) COMMON TRUSS TO ROOF SHEATHING. 6. SET 2 x 6 2 RIDGE BEAM. SUPPORT WITH 2 x 4 POSTS SPACED 48' O.C. BEVEL BOT OM OF POST TO SET EVENLY ON THE SHEATHING. FASTEN POST TO ROOF SHEATHING WITH (3) 10d TOE NAILS. 7. FRAME VALLEY RAFTERS FROM VALLEY PLATE TO RIDGE BEAM. MAXIMUM RAFTER SPACING IS 24' O.C. FASTEN VALLEY RAFTER TO RIDGE BEAM WITH (3) 16d NAILS. FASTEN VALLEY RAFTER TO VALLEY PLATE WITH (3) 16d TOE NAILS. 8, SUPPORT THE VALLEY RAFUS WITH 2 x 4 P057S 48' O.G, (OR LESS) ALONG EACH RAFTER. INSTALL POSTS IN A STAGGERED PATTERN AS SHOWN ON PLAN DRAWING. ALLIGN POSTS WITH TRUSSES BELOW. FASTEN VALLEY RAFTER TO POST WITH (4) 1 od NAILS. FASTEN POST TO SHEATHING WITH (3) 16d TOE NAILS. FOR PURLIN APPLICATION, CONNECT 2x4 POST TO FACE OF TOP CHORD WITH (4) 1OD NAILS. CODE *ACTUAL* FLANGE WIN SIZES CK OPENING F GHT OOUNG) 12 191 8X26 20X261 8 13 191 BX3838 20X381 2 14 191 8X5058 20X5034 15 191 8X63 20X6318 16 191 8X72 20X721 8 17 191 8X84 20X841 8 1/2 32 261 8X26 2738X261 8 1 233 261 8X3838 2738X381 2 1 234 261 8X5058 2738X5034 1 235 261 8X63 2738X631 8 1 236 26118 X72 2738X721 8 1 237 261 8X84 2738X841 8 22 36X26 2738X261 8 23 36X3838 3778X381 2 24 36X5058 3778X5034 245 36X501 4 3778X5638 25 37 X 63 EGRESS 37 7/8 X 63 1 8 26 37 X 72 EGRESS 37 7/8 X 72 1 8 27 37 X 84 EGRESS 37 7/8 X 84 1 8 485 48 X 63 EGRESS 49 X 63 1 8 32 53 1 8 X 26 54 X 26 1 8 33 53 1 8 X 38 318 54 X 38 1 2 34 531 8X5058 54X5034 1 8 X 1/4 X _ 35 53 1 8 X 63 EGRESS 54 X 63 1 8 36 53 t 8 X 72 EGRESS 54 X 72 1 8 37 53 1 8 X 84 EGRESS 54 X 84 1 8 NOTE 11U LING Th100N5 7OGEIFER TAKE-�ZBLOCK OPEIt SQE AND AOO (1) ACTUAL 9InDOw SQE FOR EACH xooNVIL w�IDOw. SuaI cxwsS DOORS BLOCK OPENING SIZE FRAM FRAME OPENING II 80 X M 80 1/4 X 8D 1/4 61 4 s 81 II f 72 X 80 1/4 X 8D 1/4 7! 4.81 9g X 8D 1/4 X 80 1/4 97 4 a 81 » tag SA x w 108 7/8 X 80 1/4 108 3A a.Q1 4�x 119 S/0 X 00 119 7/8 X W 1/4 121 t M tm s wax 142 5/8 X 80 142 7/8 X E 1/4 144 : 81 !- 143 5A X 8D 143 7/5 X W 1/4 145 a M 41 191 S/8 X 8D 1123 7/8 X 1/4 193 3A a 81 KITCHEN ELEVATION #1 2x4 RAT RUNS OR 2X4 BLOCKING 4'-0' O.C. FOR FIRST FOUR FRAMING SPACES FROM EACH END STRAP TRUSS W/ %FSON HETA20 (OR EQUAL) USING (6) 10d NAILS (MIN) 6 48' O.C. VALLEY PLATE (SEE NOTE #4) IP400TSTE F8 GABLE ENO, COMMON LNE LOAD = 30 PSF (MAX) DEAD LOAD = 15 PSF (MAX) D.O.L. INC. = 1.15 ASCE 7-10 (MWFRS) 140 MPH NOTE 48' O.C. MAXIMUM POST SPACING 2X6 PLATE CONTINUOUS 14' LENGTHS MINIMUM CONNECTED TO CMU WALL W/1/2` X 8' ANCHOR BOLT 2-16d O 32' O.C. �- BOND BEAM L- 5d COOLER NAILS OR GWB54 0 7• Q.c. GABLE END TRUSS CONNECTION STRUCTURALLY CONT#&KUS WAU. NOT M SCALE ROOF SHEATHING PER GENERAL NOTES ATTACH TO TOP CHORD BACK NAIL W/ (2) W/SIMPON H2.5 (OR 12d COMMONS EQUAL) 2X4 LADDER/OUTLQOKER 'T' OR "L' 24" OVERHANG SPACE 24" (BRACING SCISSOR TRUSS O.C. 12"/16' OVERHANG (REQ'D) SPACE 48" O.C. NOT SHOWN SIDING OR SHEATHING (SEE GENERAL NOTES FOR PANEL SIZE & \Z12.4 ATTACHMENT) RAT RUNS OR 2x4 BLOCKING 48' O.C. FOR FIRST FOUR FRAMING ATTACH 2X4 DIAPHRAM TO SPACES FROM EACH END ATTACH GABLE TRUSS VERTICAL TO EACH BOTTOM CHORD MIN. (2) WEBS W/(2) 1 od 10d COMMON NAILS COMMON NAILS RYWALL NAILER GABLE END TRUSS KNEE WALL TRUSS BRACING PER STRAP TRUSS W/ SIMPSON TRUSS MFG. SPECS HETA20 (OR EQUAL) USING CONTINUOUS (6) 10d NAILS (MIN) O 48' BOND BEAM W/ O.C. (1) #5 REBAR CATHEDRAL @ GABLE DETAIL STRUCTURALLY CONTINUOUS WALL NOT TO SCALE ?V�