Loading...
HomeMy WebLinkAbout38250 A Ave (2)I BB -3 4 5 6- --7-1 8 9----10--r-11---12 13 T 141516T1718T19 r 20 i 21--7-22 r 23 r--24--I 25 7-26--27----- T-28T29 r 30--r-31T32 7--33 34----T--35 r 36 F N X i A�' w N BATTERY CALCULATION SECONDARY POWER SOURCE REQUIREMENTS STANDBY CURRENT SECONDARY ALARM (AMPS) CURRENT (AMPS) QTY PART NO DESCRIPTION CURRENT DRAW (A) TOTAL (A) CURRENT DRAW (A) TOTAL 1 CPS-24 Card Fire Alarm Power Supply 1 x 0.00 = 0.00 1 x 0.00 = 0.00 PANEL COMPONENTS Card 1 CPU-320 NFS-320 Fire Alarm 1 x 0.25 = 0.25 1 x 0.25 = 0.25 Control Panel Main Board (Central Processing Unit) CIRCUIT SYMBOL QTY PART NO DESCRIPTION CURRENT TOTAL (A) CURRENT TOTAL (A) DRAW (A) DRAW (A) Annunciator, Terminal ANN ® 1 FDU-80 mode. 80-character, 1 x 0.00 = 0.00 1 x 0,00 = 0.00 backlit LCD display Intelligent Non -Relay �s 8 DNR/w FSP-951R Photoelectric Duct 8 x 0.0003 = 0.0024 8 x 0.0003 = 0.0024 Detector 0 Addressable Dual Monitor 1 FDM-1 Module W/ FloshScon, 2 1 x 0,00 = 0.00 1 x 0.00 = 0.00 Class B ZDM 1 FDM-1 Addressable Dual Monitor 1 0.0007 0.0007 1 0.0007 Module W/ FlashScan, 2 x = x 0.0007 = Class B Addressable Monitor Module W/ FloshScon, L1 ® 1 FMM-1 Supervises Class A or 1 x 0.0003 = 0.0003 1 x 0.0003 = 0.0003 Class B of Dry Contact Input DETECTOR, SMOKE, 58 FSP-951/B300-6 ADDRESSABLE PHOTO 58 x 0.0002 = 0.0116 58 x 0.0045 = 0,261 W/STANDARD BASE Intelligent Addressoble Q 16 FST-951/B300-6 1357 (57'C) Thermal 16 x 0.0003 = 0.0048 16 x 0.0003 = 0.0048 Detector W/ nashscon, Plug-in Detector Bose El 20 NBG-12LX Manual Pull Station, 20 x 0.0003 = 0.006 20 x 0.0003 = 0.006 Addressable 6 P2RL -Wire, Horn Strobe, Red 6 x 0.00 = 0.00 6 x 0.054 = 0.324 V1 15cd 11 SRL Strobe, Red 15cd 11 x 0.00 = 0. DO 11 x 0.043 = 0.473 ®4 7 P2RL -Wire, Horn Strobe, Red 7 x 0.00 = 0.00 7 x 0,054 = 0.378 15cd V2 3 P2RL -Wire, Horn Strobe, Red 3 x 0.00 = 0.00 3 x 0.121 = 0.363 75cd 10 SRL Strobe, Red 15cd 10 x 0.00 = 0.00 10 x 0,043 = 0.43 TOTAL 0.2758 TOTAL 2.4932 STANDBY (A) ALARM (A) REQUIRED STANDBY TIME = 24.00 HOURS REQUIRED ALARM TIME = 5 MINUTES SECONDARY STANDBY LOAD 0.2758 2.4932 x 24.00 x 0.0833 1 = 6.6192 AH 1 = 0,2078 AH SECONDARY ALARM LOAD STANDBY AND ALARM LOAD SUBTOTAL 6.827 AH x 1.20 DERATING FACTOR SECONDARY LOAD REQUIREMENTS (AMP HOURS) 8.1924 AH PROVIDE (2) 12V 12AH BATTERIES 0 24VDC DEVICE LEGEND DEVICE SYMBOL QTY. MANUFACTURER PART NO. DESCRIPTION MOUNTING BOX SS 3 DITEK DTK-120HW PROTECTS A 120V ® 20A WITHIN 3' OF PANEL D CIRCUIT 7788F FIRE ALARM ® 1 DYNAFIRE 7788F-ULP SUBSCRIBER WITH INTELLIPRO ADJACENT TO FACP PROVIDED FIRE FULL DATA MODULE FACP 1 NOTIFIER NFS-320 FIRE ALARM CONTROL PANEL, 72" TO TOP OF ENCLOSURE PROVIDED ADDRESSABLE 1 NOTIFIER CPS-24 CARD FIRE ALARM POWER SUPPLY INSIDE FACP N/A CARD NFS-320 FIRE ALARM 1 NOTIFIER CPU-320 CONTROL PANEL MAIN BOARD INSIDE FACP N/A (CENTRAL PROCESSING UNIT) NAC 2 NOTIFIER FCPS-24S8 8-AMP, 24-VOLT POWER 72" TO TOP OF ENCLOSURE PROVIDED SUPPLY 2 NOTIFIER FCPS-24S8 FIRE ALARM POWER SUPPLY INSIDE NAC N/A MAIN BOARD MAIN BOARD ANNUNCIATOR, TERMINAL AA 1 NOTIFIER FDU-80 MODE. 80-CHARACTER, 60" TO CENTER OF BOX A BACKLIT LCD DISPLAY TERMINAL MODE. 1 NOTIFIER FDU-80 CARD 80-CHARACTER, BACKLIT LCD INSIDE FAA N/A DISPLAY DETECTOR, SMOKE, 0 59 NOTIFIER FSP-951 B300 ADDRESSABLE PHOTO CEILING AS PER DRAWING A -6/ W/STANDARD BASE INTELLIGENT ADDRESSABLE i0 16 NOTIFIER FST-951/B300 135-F (57'C) THERMAL CEILING AS PER DRAWING A -6 DETECTOR W/ FLASHSCAN, PLUG-IN DETECTOR BASE 21 NOTIFIER NBG-12LX MANUAL PULL STATION, 48" TO CENTER OF BOX C ADDRESSABLE �s 8 NOTIFIER DNR INTELLIGENT NON -RELAY PHOTOELECTRIC DUCT INSTALLED MECHANICAL D FSP-951R CONTRACTOR DETECTOR ADDRESSABLE MONITOR MM 2 NOTIFIER FMM-1 MODULE W/ FLASHSCAN, SUPERVISES CLASS A OR WHERE SHOWN ON DRAWING A CLASS B OF DRY CONTACT INPUT [EIDM 1 NOTIFIER FDM-1 ADDRESSABLE DUAL MONITOR W/ FLASHSCAN, 2 ADJACENT TO SPRINKLER A MODULE RISER CLASS B HOOD 1 GENERIC HOOD SYSTEM CONTACT DEVICE BY OTHERS N/A MONITOR DH 8 NOTIFIER FM998 24V DOOR HOLDER COORDINATE WITH DOOR C CONTRACTOR ( 48 SYSTEM SRL STROBE, RED 80" TO BOTTOM OF BOX A SENSOR ®4 53 SYSTEM P2RL 2-WIRE, HORN STROBE, RED 80" TO BOTTOM OF BOX A SENSOR Q 1 GENERIC WATERFLOW CONTACT DEVICE 8Y OTHERS D �I SWITCH 1 GENERIC TAMPER SWITCH TAMPER SWITCH BY OTHERS D z B 0 C H Cl) �Q o� D o 00 a=W 11 Cn =< U)W LL W `1C1 tR 00 E o WO¢ Q _ju- > u! -j Z Q �Uu.- F G H J K Panel BACKBOX LEGEND L Total Used Current: (All Circuits) 1.9680A • 2-118" 2-118" 1-112" DEEP 4" SQ' DEEP DEEP Point -To -Point Voltage Drop Calculation for Circuit V1 Starting Calculation Voltage: 20.4000v Minimum Operational Voltage: 16.0000v Total Circuit Current: 0.7970A Total Distance: 312.0502' Voltage Drop: 0.7582v End Of Line Voltage: 19.6418v Percent Drop: 3.72 % Wire GA=#14 AWG Distance measured using drawn segment lengths with 10.00 % additional length calculated Device Label Part No. Description Device Current Distance From Voltage At Voltage Drop Voltage Drop Previous Device Device From Source Percent V1.001 P2RL 2-Wire, Horn Strobe, Red 0.0540A 22.6497' 20.2892v 0.1108v 0.54 % 15cd V1-002 P2RL 2-Wire, Horn Strobe, Red 0.0540A 16.5824' 20.2135v 0.1865v 0.91 % 15cd V1.003 SRL Strobe, Red 15cd 0.0430A 16.9901' 20.1416v 0.2584v 1.27 % V1-004 SRL Strobe, Red 15cd 0.0430A 6.8868' 20.1143v 0.2857v 1.40 % V1-005 SRL Strobe, Red 15cd 0.0430A 10.0027' 20.0773v 0.3227v 1.58 % V1-006 P2RL 2-Wire, Horn Strobe, Red 0.0540A 12.5857' 20.0340v 0.3660v 1.79 % 15cd V1-007 SRL Strobe, Red 15cd 0.0430A 12.5696' 19.9950v 0.4050v 1.99 % V1.008 SRL Strobe, Red 15cd 0.0430A 19.2512' 19.9402v 0.4598v 2.25 % V1.009 P2RL 2-Wire, Horn Strobe, Red 0.0540A 32.5323' 19.8563v 0.5437v 2.67 % 15cd V1-010 SRL Strobe, Red 15cd 0.0430A 47,5956' 19.7494v 0.6506v 3.19 % V1.011 SRL Strobe, Red 15cd 0.0430A 9.9054' 19.7297v 0.6703v 3.29 % V1-012 SRL Strobe, Red 15cd 0.0430A 13,9855' 19.7057v 0.6943v 3.40 % V1-013 SRL Strobe, Red 15cd 0.0430A 15.1823' 19.6836v 0.7164v 3.51 % V1-014 SRL Strobe, Red 15cd 0.0430A 6.6334' 19.6757v 0.7243v 3.55 % V1-015 P2RL 2-Wire, Horn Strobe, Red 0.0540A 9.8714' 19.6665v 0.7335v 3.60 % 15cd V1.016 SRL Strobe, Red 15cd 0.0430A 19.9848' 19.6546v 0.7454v 3.65 % V1-017 EOL P2RL 2-Wire, Horn Strobe, Red 0.0540A 38.8413' 19.6418v 0.7582v 3.72 % 15cd Point -To -Point Voltage Drop Calculation for Circuit V2 Starting Calculation Voltage: 20.4000v Minimum Operational Voltage: 16.0000v Total Circuit Current: 1.1710A Total Distance: 388.7220' Voltage Drop: 1.3784v End Of Line Voltage: 19.0216v Percent Drop: 6.76 % Wire GA=#14 AWG Distance measured using drawn segment lengths with 10.00 % additional length calculated Device Label Part No. Description Device Current Distance From Voltage At Voltage Drop Voltage Drop Previous Device Device From Source Percent V2-001 P2RL 2-Wire, Horn Strobe, Red 0.1210A 36.2727' 20.1392v 0.2608v 1.28 % 75cd V2-002 P2RL 2-Wire, Horn Strobe, Red 0.0540A 4.6917' 20.1090v 0.2910v 1.43 % 15cd V2-003 P2RL 2-Wire, Horn Strobe, Red 0.0540A 23.7324' 19.9638v 0.4362v 2.14 % 15cd V2-004 P2RL 2-Wire, Horn Strobe, Red 0.121OA 20.1726' 19.8471v 0.5529v 2.71 % 75cd V2-005 P2RL 2-Wire, Horn Strobe, Red 0.0540A 28.7587' 19.7022v 0.6978v 3.42 % 15cd V2-006 P2R1_ 2-Wire, Horn Strobe, Red 0.1210A 16.7687' 19.6232v 0.7768v 3.81 % 75cd V2-007 SRL Strobe, Red 15cd 0.0430A 27,2300' 19.5152v 0.8848v 4.34 % V2-008 P2RL 2-Wire, Horn Strobe, Red 0.0540A 39.9156' 19.3674v 1.0326v 5.06 % 15cd V2-009 SRL Strobe, Red 15cd 0.0430A 36,5924' 19,2441v 1.1559v 5.67 % V2-010 SRL Strobe, Red 15cd 0.0430A 15.0154' 19.1974v 1.2026v 5,90 % V2-011 SRL Strobe, Red 15cd 0.0430A 7,1731' 19.1770v 1.2230v 5.99 % V2-012 P2RL 2-Wire, Horn Strobe, Red 0.0540A 8.9915' 19.1538v 1.2462v 6.11 % 15cd V2-013 SRL Strobe, Red 15cd 0.0430A 9,5333' 19.1324v 1.2676v 6.21 % V2-014 SRL Strobe, Red 15cd 0.0430A 9.1427' 19.1143v 1.2857v 6.30 % V2-015 P2RL 2-Wire, Horn Strobe, Red 0.0540A 17.6849' 19.0839v 1.3161v 6.45 % 15cd V2-016 SRL Strobe, Red 15cd 0.0430A 13.1504' 19.0656v 1.3344v 6.54 % V2-017 SRL Strobe, Red 15cd 0.0430A 9.7008' 19.0547v 1.3453v 6.59 % V2-018 SRL Strobe, Red 15cd 0.0430A 13.1194' 19.0435v 1.3565v 6.65 % V2-019 SRL Strobe, Red 15cd 0.0430A 18.4695' 19.0325v 1.3675v 6.70 % V2-020 EOL P2RL 2-Wire, Horn Strobe, Red 0.0540A 32.6063' 19.0216v 1.3784v 6.76 % 15cd M 4' SQ. 1-1/2" BLANK SINGLE 4-11/16' 4-11/16" OCTAGON EXT. RING PLATE GANG BOX SQ. BOX EXT, RING BOX A - 4" BOX 2-1/8" DEEP N B - 4" BOX WITH ROUND RING OR OCTAGON BOX C - 4" BOX 2-1/8" DEEP WITH SINGLE GANG RING D - 4" BOX 2-1/8" DEEP WITH BLANK PLATE E - 4" BOX 21/8" DEEP WITH EXTENSION BOX O P CABLE AND WIRE LEGEND AW RESISTANCE CE LABEL PART NO (OSTANSTAN DESCRIPTION TOTAL LENGTH B 994 14 3.07 SOLID COPPER FPLR ANALOG 3,371.8093' UNSHIELDED R 982 18 7.77 SOLID COPPER FPLR ANALOG 269.7039' UNSHIELDED S 990 16 4.89 SOLID COPPER FPLR ANALOG 3,470.8386' UNSHIELDED I S T General Notes System Installation in accordance with NFPA-70 (2014 Edition), NFPA-72 (2013 Edition) Life Safety 101(2015 Edition) V Florida Building Code (6th Edition) Florida Fire Prevention Code (6th Edition) Manufacturers Installation Instructions All other codes mandated by local AHJ 3 X0 Connect 120vac Dedicated circuit to Fire Panel, a a install lock -out device on circuit breaker at electrial panel, and mark panel Location and circuit number Y Cd :1 w on front of FACP. D S'� �%,� i, i r! Ik i!riJF x ♦� Verifylocation of all tamper and waterflow switches , ,�®'®�� G�'�+S•• prior to installation. :i A ey " •r •.9"P•_ (y!Y`-. 01 DYNAFIRE DYNA 4 P) ET I Alarm Wireless Alarm Monitoring DYNAFIRE INC. PHONE (407) 830-6500 - FAX (407) 831-1347 109E Concord Drive CASSELBERRY, FLORIDA 32707 E-MAILs info@dynafire.com Qualifier: STEVEN HATCH STATE LICENSE # EF20000528 WEBSITEs WWW.DYNAFIRE.COM -6-111 Z�U Q Cp N d N � WQ' E 06 Cn >% 0 2 r � co00 J CU ww� N=LL a cc U W W 0 W a O cc I-- V) O U cc 0 LL In w N to O N O N CV O DYNAFIRE, INC. ENGINEERING SERVICES P.E. No. 33868 Robert Munroe N 4`111- LO CM M A- M0 L O Cn E � Jc L /c �.i W N CASSELBERRY, FLORIDA 407-830-6500 JOB NUMBER: ISSUE DATE: DRAWN BY: CHECKED BY: PM: 'rr 6830F03 02/07/2020 John Creamer Cory Abbott Bob Seekamp Fire Alarm Shop Drawings 3 14 15 1b 7 18 9 110 111 112 113 114 11516 117 118 119 120 121 122 123 124 125 126 127 128 129 t30 131 132 1 33 34 35 -- - M O w O co i a� H M CC Q x 36 FA-1 3 4 1 5 6r--7r-8 9-7-1012-T13r14---T--15---7-1617—I-18r19--r-20--21—T22T-23i-24r-251-26r--27T28T29----7--30--31T--32---T-33r34-35 36 R N A� w N Cn U Z a 0 `1 DYNARRE nt )YNA ET j Wireless j Alarm Monitoring r BB O-C Matchline FIRE ALARM PLAN - 1st FLOOR - BLDG A -UPPER SCALE: 1/8" = 1-0" 1/r\/ r'%l A \ 1 W Q 5 W CG DYNAFIRE INC. PHONE (407) 830-6500 - FAX (407) 831-1347 109B Concord Drive CASSELBERRY, FLORIDA 32707 E-MAID info@dynafire.com Qualifier: STEVEN HATCH STATE LICENSE # EF20000528 WESSITEs WWW.DYNAFIRE.COM Z 0 cc Z 0 u 0 a W D N N 120 Q O N L0 00 M DYNAFIRE, INC. ENGINEERING SERVICES P.E. No. 33868 Robert Munroe N LO CM M U) Jc Jc CL a� N CASSELBERRY, FLORIDA 407-830-6500 ' SOB NUMBER: i" -ISSUE DATE: rye DRAWN BY: 1041 CHECKED BY: PM: 6830F03 02/07/2020 John Creamer Cory Abbott Bob Seekamp Fire Alarm Shop Drawings FA-2 A x 3 4 5 6 7 8- 9 10 11 12 13 14 Ixz i 16 17 10 10 20 21 22 11 24 25 26 27 28 29 30 31 32 33 34 35 36 N lJ V W 3-- 1 4 5 6 1 7 18 9-1 1012 T-13—r-14 f 1516 7-17—r 18 f 19---r-20 f 21 , 22 f 23----r--24--,-25 26 --T 27--—28T29T30 31— —32 r-33 ,--34—r-35 36 N X A10 M Lr_.I N N C.� Z 0 B C D E F G )) tl FATC NAC NAC-2•V2-011 �J N5 C-1 V2,005 F Lt#1025 j 75cdtF Matchikre FA-2 2 D _ FA-2 Matchline 1 S FA-3 KITCHE L1005 L1 �039 FA-3 1 S NAC-1 •V2 *02 2 6 CHAT ROOM 1 B+ JB 2 FA-3 FA 4 01 110cd 1 S rjO0K t OFFICE2DJB S Ma iire1 8 H NAC-1•V .008 L1 •DO66 L1 •D050 JB EPER 2 B75cd 1B Ll •D071 CHAT ROOM ' NAC-1 •V3-007 1 � CHAT R 1� sc� 1 S PRIVATE R„R , S 2 2 B 0 1 B Ll 0051 NAC-1 •V3.008 1 S ! 0 75cd NURSE STATION ^' Ll 0081 AC-1 •V3-003 NAC-1 • MED ROOM NAC•va-0o1 15cd 15cd PUBLIC R.R. 11ocd 2 B 2 IC R.R. PUB i F—i NN-001D2 BL7 64 1 g 1 D '•`- 2 B 2 B NAC-1•V3.009 1 6 1 S--- -- 15cd 2 ,B 2 B 2 6 1 S 1 D 75 d NAC-1 •V3-010 JB 2 6 JB i 1 S 1 S t D 1$ 2 B NAC-1 •V3005 1 B B 2 6 15cd 2 B 1-1 1 S 1 D 2 B 1 S 1 S Ll •D063 JB 1 S J 2 CORRIDOR B � 2 6 B Z 2B L1 •DO68 1 D S Ll •D067 1 D K ACTIVITY DAY ROOM Ll -D082 1 S NAC-1 •V3001 IJ 15cd 1 B 2 B 1 S 2 6 NAC-1 •V4-002 B ! 1 S 1 S 110cd 1S 1B 1 S CORRIDOR T1,17, 1 S 2 NAC-t •V2-001 OFFICE EXISTING KX ! u�lota 75cd OFFICE Ti� L1 D053 2 B F 2DIS 2 NAC-1 •V3-002 L1 •D065 j L1 D062 SHOWER SHOWER I 1 B Ll 0069 15cd STORAGE T M ASST, ADMINISTRATOR RECEPTIONIS! 5L11 #A017 NAC-1 •V3-011 B 1 S 75cd j S L1 D055 2 B S Ll0054 1 B NAC-1 •V3-012 EX Ll •D056 1 S 1 S i N 15cd SEMI_PR�NATTE 1 S 1 S L1•D057 1S B ADMINISTRATORF—L) - 2 B L1 •DO 8 l ! 0 0 L— - - - _ -- STORAGE L1 0070 EMPLOYEE LOUNGE O 15 Cd-1 •V4403 EMI•PRIVATE _ O I tltlzLaa i I SEMI -PRIVATE 1 S i P i SEMI -PRIVATE t L1 0059 827 SEMI-PRIW 0 Q 0 0 B SEMI -PRIVATE B29 ,S R ! S SEMI•PR�NATtE SEMI -PRIVATE � l 0 Ll0060 0 T 0 0 SEMI -PRIVATE 4 SEMI -PRIVATE I ,B U 1 5 _� i - — - -7—-��- — ----- I SEMI-PRIVAT EMI,PRIVAT V I I i �CIDi Ll •oos, to �0 j -W B SEMI-PRIVATE1 g SEMI -PRIVATE (I to FIRE ALARM PLAN - 1st FLOOR - BLDG A -LOWER SCALE: 118" = 1-0" 0 4' 8' 16' Makhllne x 4J x a y x BB 0 I N M O F�4 O M co / r1 DYNAFIRE nf DYNA ET I Airelegs Alarm Monitoring a U N W 0 W H DYNAFIRE INC. PHONE (407) 830-6500 - FAX (407) 831-1347 109B Concord Drive CASSELSERRY, FLORIDA 32707 E-MAIL: info@dynafire.com Qualifier: STEVEN HATCH STATE LICENSE # EF20000528 WEBSITE: WWW.DYNAFIRE.COM 0 H U D CC N Z 0 U O 0 W to IN O N O N \ O N O W N T H€ J � Q Lij 2" DYNAFIRE, INC. ENGINEERING SERVICES P.E. No. 33868 Robert Munroe N 'qqt M M AY, i FP cl nCL W N CASSELBERRY, FLORIDA 407-830-6500 SOB NUMBER: 3SSUE DATE: `DRAWN BY: CHECKED BY: PM: 683OF03 02/07/2020 John Creamer Cory Abbott Bob Seekamp Fire Alarm Shop Drawings FA-3 C] x 3 1 4 1 5 6 17 18 9 110 111 1 12 113 114 115+--16 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 11. L11 IL 11 I .... .0. �:I I [',,I 4li.,-::.,a� i. 16 A B BB ..0 3 4 5 6--1 7 -1 8 1 9 1 10 1 1-----12— -13-1 14T15-- —16—, 17— —1819 1 20 -I 21--T-22— 1 23 r-24 I 25 1--26— 27—I 28 T-29 I 30T31 -32 33 r-34—r-35 36 N X A` 0 M Li IV N C.� Z 1 S � 7LI B 7 i P��2� I - PRIVATE 2 E -PRIVATE I A A� L1 •D021 0 � C V2-008 15cd 1 B i 1S I D AE$q P I O SyE I -PRIVATE �� 1 A Al 2 L1-D020 1 B 5 n09 O 1 S 1 A19 SEMI -PRIVATE V2-010 Toy15cd 1 B L1 •D019 V2- SEMI -PRIVATE EMI-PRNATE EMI -PRIVATE I -PRIVATE F gE�M 012 AOTo3LET 15cd OBtZG PREP A a V2 15cd F -— F 1 8 v2-0t 1 B i5 Li 41012 1 S L1 #1013 'I I �� HING ` 5 d07 STA, A� A07 6 NAC-2•V2005 1 S -15cd A V2.0-14 1 B 1 75cd 1B 1 S 1 B 1 N 23�� rll'AC- •V2 008 H 95cd 1 B T$ AFF 1 B 7;�) DAYC ARE NAC-2•V 9d PME T C�7� _zd i� PHYS. THEIZ4 Y 6b NACLIVIN 1 S 1 5 V2-020 t� 1 S F L14A006 - 2•V2-007 sscd A05 Z 2 Z A NAC-2•V2-004 L10015 L10016 Lt M018 15cd OV2 -015 1 S 1 B 15cd 75cd TOILET V2-006 1 B 1 B 003 75cd I 1 B 1 tV2-011V2-0,cd 1 15cd \X/ TOILET TOILET O OUST DIAL L1 D014 1 V2-017 0 1 B V2-018 �� C04 15cd 15cd O / 15cd 5 d 2•V2-003FYI 1 B 1 g 1 BUL'tj QUIET STUDY CLEAN UTIL SOILED UTI EQUIP STO AEG F F TOE ® A39 A38 A37 A36 l A35 S J Lt-MO14 1 S L14A011 L1-0017 1 S 1 S 1 S 1 S 1 S PRIVATE PRIVATE Z nLl-D037 D1 1 S A MINING AteAL1 •Do38 L1 M036 L1-0035 NAC-2•V2-010 1 BNAC-2•V2-009 15cd 15cd 115 d AC-2-V2-002 1 B V2-005 15cd D R LOBBY 1 K NAC-2•V2-001 DOI-- V2-004 i 15cd 2 75cd CHAPEL HOUSEKEEPING SOCIALSERV.DIR DIRE OF NURSING EXAMINATION D17FFDEV.000RD, L1 •DO34 L1 •D013 i 1S 1B 1 B O TOILET 15 020 O TOILET UT_Z L1 •D012 RECE� PT$ IONIST Nac-z 21 v2-002 by j L1 •D033 t L1-D022 15cd 1 75cd V2-001 75cd 1S 1B L1 #1001 MM 1 S 1 S 1 6 o I N NAC-2• t d 0 15cd 1 B U Q L1 M001 ACTN.MINING L1-D023 �G R00� I 1 S LNIO NG ROOM B09IPRIVATE SEMI -PRIVATE IN MI -PRIVATE B D 3 L1 011 B1� O Z 1B 15cd NAC-2 •V1-002 1 S d R 75cd �ATHING L1-D024 D22 1 — 1 S NAC-2•V1 503 F d O I 1 16 v1-01 s u•Mooa NAc-z•vt-0oa 2 L1 •DO10 TOILET CUSTODIAL 75cd P 1 S 15cd D R B—or— B04 B01 V1 -002 ACTIV.MINING 15cd PO 0� Oo O Oo 1B 1B li R ATE CRC TE 1 u004 L1-0028 F CLEAN UTIL TO LET L7 4AO02 QUIET STAY O F 1 S 2 S 1 S C3BA5HING C37 L Nnc3 2•V1 039 15cd5cd 2 L1 •D002 2 i V1-003 L1 -D004 L7 U005 O O NAC-2•V1 �L.1 •DO 1 S 75cd 1 6 Vt-017 E[ 1 NAC-2•Vi-VI1 6 1 8 75cd CUSTODIAL 1 C RR 1 S 75cd j l 1 S 75cd CT(jQ— 1 Bi 7 2 NAC-2•V7019 NAC-2•V1-007 1 B 1 75cd 1 B teed vt -0oa Lt -0003 R NAC-2•V1-005 QUIETSTUDY 75cd 75cd I NAC-2•VI-020 EM 1 B 1 S 75cd 1 S 1 5 NAC-2•V7-016 1 B V1-095 1 B Moof 2 15cd 1 S 75cd OL D23 ? Z L1 0029 L1 0027 L1 0026 1 -1 B Vt •014 F LIVING ROOM Vt -005 15cd S` L1 M�� CLEAN UITL 15cd V1013 009 O 0 CCLLEEAANN LL 1 B B3 15c C B� STNURSE21 F NGE 1 S ® 1 8 C 8 SEMIPRIVATE EMI -PRIVATE 11 B 1 B NAC-2•v1-01 1 B L� v1-0os 75cd T t Sc L10006 -0t 1 NOURISH C� Ell BATHING COLS 7CTRI� SOILED375 tl07 C33CLEAN LINEN C22 NOURISH 75cd L NAC-2 •V1-008 V1-010 C2D20 PREP V1-012 C1 _NAC-2•V11513 1 B N d 2•V1 -014 75cd 15cd 1 B 15cd 0 SEMI P SEMIS EMI^ PRIVATE SEMIS PRIVATE R D R 0 C3� C 7 C2D0 G PREP 1 B 1 B Z rlUD008 O1 S U AC-2•Vt-012 1 Lt •D030 15cd S O SEMI-P IRVATE cuti SEMI- RNAT LOU GE I I 1 1 WI v1006 O V._—__�— __..____ _ --- --fit— _ AC-2•V1.01'F�— AC-2•V1fli -- _ �_� 75cd 15cd I75cd 2 i � L1 0031 1 B 1 s � L1 -D007 SEMI PRIVATE F'�LG SEMIVATE O 1EMI-PRIVATE �� i a W y �1 DYNAFIRE � nf Wireless AlarmMonitoring W Q 0 DYNAFIRE INC. PHONE (407) 830-6500 - FAX (407) 831-1347 109E Concord Drive CASSELBERRY, FLORIDA 32707 E-MAIL: Info@dynafire.com Qualifier: STEVEN HATCH STATE LICENSE # EF20000528 WESSITE: WWW.DYNAFIRE.COM 2 am Uj N 0 DC H V) V U CC 0 0 W D V) tN O N O N N O W N T H€ J � Qa WLL I O Nn , V M/ w co DYNAFIRE, INC. ENGINEERING SERVICES P.E, No. 33868 Robert Munroe N M co �' LL CASSELBERRY, FLORIDA 407-830-6500 b a• H � y61 'da NUMBER: 6830F03 BB I LV M O W O M co H a CC , Q x 3 4 1S 6 7 1 8 1 1 9 1 10 1 11 1 12 1 13 1 14 1 15-1 16 1 17 1 18 1 19 120 1 21 1 22 1 23 1 24 1 25 1 26 1 27 1 28 1 29 1 30 1 31 1 32 1 33 1 34 1 35 1 36 qUE DATE: BRAWN BY: CHECKED BY: PM: w '^ V / 02/07/2020 John Creamer Cory Abbott Bob Seekamp Fire Alarm Shop Drawings FA-4 Wl 6 A 3- 1 4 5 61-7 8 1 9-1 10 T 11 1 12--1314 -T--15T16-----T--17---F-18T19---r--20---r---21T22- -23T24 r 25-I-26T27--r--28---T--29T30T31----T--32T33T34--r-35---r--36 2 N X Ao Ill Point -To -Point Voltage Drop Calculation for Panel NAC-1 Circuit AUX1 Starting Calculation Voltage: 20.4000v Minimum Operational Voltage: 16.0000v Total Circuit Current: 0.1200A Total Distance: 243.6176' Voltage Drop: 0.1152v End Of Line Voltage: 20.2848v Percent Drop: 0.56 % Wire GA=#14 AWG Distance measured using drawn segment lengths with 10.00 % additional length calculated Device Label Part No. Description Device Current Distance From Voltage At Voltage Drop Voltage Drop Previous Device Device From Source Percent NAC-I-AUX1-001 FM998 24V Door Holder 0.0200A 71.6597' 20.3472v 0.0528v 0.26 % NAC-1-AUX1-002 FM998 24V Door Holder 0.0200A 9.4507' 20.3414v 0.0586v 0.29 % NAC-1-AUX1-003 FM998 24V Door Holder 0.0200A 65.6708' 20.3091 v 0.0909v 0.45 % NAC-1 -AUX1 -004 FM998 24V Door Holder 0.0200A 10.7828' 20.3052v 0.0948v 0.46 % NAC-1-AUX1-005 FM998 24V Door Holder 0.0200A 79.7670' 20.2856v 0.1144v 0.56 % NAC-I-AUX1-006 FM998 24V Door Holder 0.0200A 6.2867' 20.2848v 0.1152v 0.56 % Point -To -Point Voltage Drop Calculation for Panel NAC-1 Circuit AUX2 Starting Calculation Voltage: 20.4000v Minimum Operational Voltage: 16.0000v Total Circuit Current: 0.0400A Total Distance: 149.4190' Voltage Drop: 0.0357v End Of Line Voltage: 20.3643v Percent Drop: 0.18 % Wire GA=#14 AWG Distance measured using drawn segment lengths with 10.00 % additional length calculated Device Label Part No. Description Device Current Distance From Voltage At Voltage Drop Voltage Drop Previous Device Device From Source Percent NAC-I-AUX2-001 FM998 24V Door Holder 0.0200A 141.4320' 20.3653v 0.0347v 0.17 % NAC-I-AUX2-002 FM998 24V Door Holder 0.0200A 7,9870' 20.3643v 0.0357v 0.18 % Point -To -Point Voltage Drop Calculation for Panel NAC-1 Circuit V1 Starting Calculation Voltage: 20.4000v Minimum Operational Voltage: 16.0000v Total Circuit Current: 0.3020A Total Distance: 304.6249' Voltage Drop: 0.3460v End Of Line Voltage: 20.0540v Percent Drop: 1.70 % Wire GA=#14 AWG Distance measured using drawn segment lengths with 10,00 % additional length calculated Device Label Part No. Description Device Current Distance From Voltage At Voltage Drop Voltage Drop Previous Device Device From Source Percent NAC-1-V1-001 SRL Strobe, Red 15cd 0.0430A 55.5294' 20.2970v 0.1030v 0.50 % NAC-1 •V1-002 P2RL 2-Wire, Horn Strobe, Red 15cd 0.0540A 77,9118' 20.1731 v 0.2269v 1.11 % NAC-1-V1-003 P2RL 2-Wire, Horn Strobe, Red 0.0540A 36.8329' 20.1268v 0.2732v 1.34 % 15cd NAC-1-V1-004 SRL Strobe, Red 15cd 0.0430A 23.9613' 20.1046v 0.2954v 1.45 % NAC-1-V1 -005 P2RL 2-Wire, Horn Strobe, Red 15cd 0.0540A 42.0101' 20.0767v 0.3233v 1.58 % NAC-1-V1.006 EOL P2RL 2-Wire, Horn Strobe, Red 15cd 0.0540A 68.3794' 20.0540v 0.3460v 1.70 % Point -To -Point Voltage Drop Calculation for Panel NAC-1 Circuit V2 Starting Calculation Voltage: 20.4000v Minimum Operational Voltage: 16.0000v Total Circuit Current: 0.9310A Total Distance: 709,3995' Voltage Drop: 2.4982v End Of Line Voltage: 17.9018v Percent Drop: 12.25 % Wire GA=#14 AWG Distance measured using drawn segment lengths with 10.00 % additional length calculated Device Label Part No. Description Device Current Distance From Voltage At Voltage Drop Voltage Drop Previous Device Device From Source Percent NAC-1-V2.001 P2RL 2-Wire, Horn Strobe, Red 75cd 0.1210A 186.3994' 19.3345v 1.0655v 5.22 % NAC-1-V2-002 P2RL 2-Wire, Horn Strobe, Red 110cd 0.1620A 54.1142' 19.0653v 1.3347v 6.54 % NAC-1-V2-003 SRL Strobe, Red 15cd 0.0430A 71.3525' 18.7815v 1.6185v 7.93 % NAC-1-V2-004 SRL Strobe, Red 15cd 0.0430A 3.3315' 18.7691 v 1.6309v 7.99 % NAC-1-V2-005 P2RL 2-Wire, Horn Strobe, Red 0.0540A 84.6010' 18.4771 v 1.9229v 9.43 % 15cd NAC-1 •V2-006 P2RL 2-Wire, Horn Strobe, Red 110cd 0.1620A 103.4875' 18.1544v 2.2456v 11.01 % NAC-1-V2-007 P2RL 2-Wire, Horn Strobe, Red 75cd 0.1210A 37.4301' 18.0748v 2.3252v 11.40 % NAC-1 -V2-008 SRL Strobe, Red 15cd 0.0430A 63.3641' 17.9873v 2.4127v 11.83 % NAC-1-V2-009 P2RL 2-Wire, Horn Strobe, Red 0.0740A 41.1361' 17.9413v 2.4587v 12.05 % 30cd NAC- 1-V2-010 P2RL 2-Wire, Horn Strobe, Red 15cd 0.0540A 55,1552' 17.9048v 2.4952v 12.23 % NAC-1-V2-011 EOL P2RL 2-Wire, Horn Strobe, Red 15cd 0.0540A 9.0278' 17.9018v 2.4982v 12.25 % Point -To -Point Voltage Drop Calculation for Panel NAC-1 Circuit V3 Starting Calculation Voltage: 20.4000v Minimum Operational Voltage: 16.0000v Total Circuit Current: 0.7830A Total Distance: 372.2100' Voltage Drop: 1.1762v End Of Line Voltage: 19.2238v Percent Drop: 5.77 % Wire GA=#14 AWG Distance measured using drawn segment lengths with 10.00 % additional length calculated Device Label Part No. Description Device Current Distance From Voltage At Voltage Drop Voltage Drop Previous Device Device From Source Percent NAC-1-V3-001 P2RL 2-Wire, Horn Strobe, Red 15cd 0.0540A 94.4206' 19.9461 v 0.4539v 2.23 % NAC-1-V3-002 P2RL 2-Wire, Horn Strobe, Red 15cd 0.0540A 50.0770' 19.7219v 0.6781v 3.32 % NAC-1-V3-003 SRL Strobe, Red 15cd 0.0430A 22.6645' 19.6280v 0.7720v 3.78 % NAC-1-V3-004 SRL Strobe, Red 15cd 0.0430A 11.4358' 19.5836v 0.8164v 4.00 % NAC-1-V3-005 P2R1- 2-Wire, Horn Strobe, Red 0.0540A 10.1312' 19.5470v 0.8530v 4.18 % 15cd NAC-1-V3-006 P2RL 2-Wire, Horn Strobe, Red 0.1210A 14.6717' 19.4988v 0.9012v 4.42 % 75cd NAC-1-V3-007 SRL Strobe, Red 15cd 0.0430A 10.2289' 19.4728v 0.9272v 4.55 % NAC-1-V3-008 SRL Strobe, Red 15cd 0.0430A 8.4479' 19.4535v 0.9465v 4.64 % NAC-1 •V3-009 SRL Strobe, Red 15cd 0.0430A 59.0342' 19.3346v 1.0654v 5.22 % NAC- 1-V3-010 P2RL 2-Wire, Horn Strobe, Red 0.121 OA 40.8084' 19.2632v 1.1368v 5.57 % 75cd NAC-1-V3.011 P2RL 2-Wire, Horn Strobe, Red 0.1210A 35,2576' 19.2277v 1.1723v 5.75 % 75cd NAC-1-V3-012 EOL SRL Strobe, Red 15cd 0.0430A 15.0323' 19.2238v 1.1762v 5.77 % Point -To -Point Voltage Drop Calculation for Panel NAC-1 Circuit V4 Starting Calculation Voltage: 20.4000v Minimum Operational Voltage: 16.0000v Total Circuit Current: 0.4320A Total Distance: 303.9336' Voltage Drop: 0.3638v End Of Line Voltage: 20.0362v Percent Drop: 1.78 % Wire GA=#14 AWG Distance measured using drawn segment lengths with 10.00 % additional length calculated Device Label Part No. Description Device Current Distance From Voltage At Voltage Drop Voltage Drop Previous Device Device From Source Percent NAC-1-V4.001 P2RL 2-Wire, Horn Strobe, Red 0.1620A 49.3933' 20.2690v 0.1310v 0.64 % 110cd NAC-1-V4-002 P2RL 2-Wire, Horn Strobe, Red 0.1620A 93.8875' 20.1133v 0.2867v 1.41 % 110cd NAC-1-V4-003 P2RL 2-Wire, Horn Strobe, Red 0.0540A 71,9484' 20.0656v 0.3344v 1.64 % 15cd NAC-1-V4-004 EOL P2RL 2-Wire, Horn Strobe, Red 0.0540A 88.7045' 20.0362v 0.3638v 1.78 % 15cd Point -To -Point Voltage Drop Calculation for Panel NAC-2 Circuit V1 Starting Calculation Voltage: 20.4000v Minimum Operational Voltage: 16.0000v Total Circuit Current: 1.0040A Total Distance: 383.7020' Voltage Drop: 1.2202v End Of Line Voltage: 19.1798v Percent Drop: 5.98 % Wire GA=#14 AWG Distance measured using drawn segment lengths with 10.00 % additional length calculated Device Label Part No. Description Device Current Distance From Voltage At Voltage Drop Voltage Drop Previous Device Device From Source Percent NAC-2-V1-001 SRL Strobe, Red 15cd 0.0430A 9.0029' 20.3445v 0.0555v 0.27 % NAC-2-V1-002 SRL Strobe, Red 15cd 0.0430A 29.9331' 20.1679v 0.2321 v 1.14 % NAC-2-V1.003 P2RL 2-Wire, Horn Strobe, Red 75cd 0.1210A 12,2275' 20.0990v 0.3010v 1.48 % NAC-2-V1-004 P2RL 2-Wire, Horn Strobe, Red 0.0540A 26.4077' 19.9697v 0.4303v 2.11 % 15cd NAC-2-V1-005 P2RL 2-Wire, Horn Strobe, Red 0.0540A 17.3663' 19.8905v 0.5095v 2.50 % 15cd NAC-2-V1-006 SRL Strobe, Red 15cd 0.0430A 24.4506' 19.7871 v 0.6129v 3.00 % NAC-2-V1.007 SRL Strobe, Red 15cd 0.0430A 11.4505' 19.7417v 0.6583v 3.23 % NAC-2-V1-008 SRL Strobe, Red 15cd 0.0430A 38.5557' 19.5989v 0.8011 v 3.93 % NAC-2-V1-009 P2RL 2-Wire, Horn Strobe, Red 0.0540A 38.1618' 19.4677v 0.9323v 4.57 % 15cd NAC- 2-V1.010 SRL Strobe, Red 15cd 0.0430A 27.8733' 19.3811v 1.0189V 4.99 % NAC-2-V1-011 SRL Strobe, Red 15cd 0.0430A 7.2778' 19.3604v 1.0396v 5.10 % NAC- 2-V1.012 SRL Strobe, Red 15cd 0.0430A 14.8986' 19.3220v 1.0780v 5.28 % NAC- 2-V1-013 SRL Strobe, Red 15cd 0.0430A 6,4064' 19.3071 v 1.0929v 5.36 % NAC-2-V1-014 P2RL 2-Wire, Horn Strobe, Red 0.0540A 12.2826' 19.2820v 1.1180V 5,48 % 15cd NAC- 2-V1.015 SRL Strobe, Red 15cd 0.0430A 17.5788' 19.2517v 1.1483v 5.63 % NAC- 2-V1-016 P2RL 2-Wire, Horn Strobe, Red 0.0540A 17.6915' 19.2260v 1.1740v 5.75 % 15cd NAC- 2-V1-017 SRL Strobe, Red 15cd 0.0430A 12.8480' 19.2116v 1.1884v 5.83 % NAC-2-V1-018 SRL Strobe, Red 15cd 0.0430A 13.1194' 19.2003v 1.1997v 5,88 % NAC- 2-V1-019 SRL Strobe, Red 15cd 0.0430A 19.5839' 19.1886v 1.2114v 5,94 % NAC-2-Vl -020 EOL P2RL 2-Wire, Horn Strobe, Red 0.0540A 26.5855' 19.1798v 1.2202v 5.98 % 15cd Point -To -Point Voltage Drop Calculation for Panel NAC-2 Circuit V2 Starting Calculation Voltage: 20.4000v Minimum Operational Voltage: 16.0000v Total Circuit Current: 0.8250A Total Distance: 204.1304' Voltage Drop: 0.5120v End Of Line Voltage: 19.8880v Percent Drop: 2.51 % Wire GA=#14 AWG Distance measured using drawn segment lengths with 10.00 % additional length calculated Device Label Part No. Description Device Current Distance From Voltage At Voltage Drop Voltage Drop Previous Device Device From Source Percent NAC-2-V2-001 P2RL 2-Wire, Horn Strobe, Red 15cd 0.0540A 17.8251' 20.3097v 0.0903v 0.44 % NAC-2-V2.002 P2RL 2-Wire, Horn Strobe, Red 0.0540A 9.2739' 20.2658v 0.1342v 0,66 % 15cd NAC-2-V2.003 SRL Strobe, Red 15cd 0.0430A 11,0021' 20.2174v 0.1826v 0.90 % NAC-2-V2-004 SRL Strobe, Red 15cd 0.0430A 9.5570' 20.1778v 0.2222v 1.09 % NAC-2-V2-005 SRL Strobe, Red 15cd 0.0430A 14.5027' 20.1216v 0.2784v 1.36 % NAC-2-V2-006 P2RL 2-Wire, Horn Strobe, Red 0.1420A 10.5356' 20.0836v 0.3164v 1.55 % 95cd NAC-2-V2.007 P2RL 2-Wire, Horn Strobe, Red 95cd 0.1420A 54.0624' 19.9355v 0.4645v 2.28 % NAC-2-V2-008 P2RL 2-Wire, Horn Strobe, Red 0.1420A 0.3667' 19.9349v 0.4651v 2.28 % 95cd NAC-2-V2-009 P2RL 2-Wire, Horn Strobe, Red 0.0540A 22.5621' 19.9124v 0.4876v 2.39 % 15cd NAC-2-V2-010 P2RL 2-Wire, Horn Strobe, Red 0.0540A 19.3236' 19.8996v 0,5004v 2.45 % 15cd NAC-2-V2.011 EOL P2RL 2-Wire, Horn Strobe, Red 0.0540A 35.1192' 19.8880v 0.5120v 2.51 % 15cd i I D E F G I H J �1 DYNAFIRE IMP DYN A E T I Wireless Alarm Monitoring W a 0 W cC DYNAFIRE INC. PHONE (407) 830-6500 - FAX (407) 831-1347 1098 Concord Drive CASSELBERRY, FLORIDA 32707 E-MAIU info@dynaflre.com Qualifier. STEVEN HATCH STATE LICENSE # EF20000528 WEBSITEi WWW.DYNAFIRE.COM C N m E Z Q U > LIJ N 2 � N 06 1-j Cn }2U) =JCU WEN Z 0 u ce H N Z 0 U cc 0 LL W N N O N O N N O 2 C) N LO W M N '/� Y , M CM All LL U) M WOMEN L r� i CIE W N DYNAFIRE, V DYNAFIRE, INC. ENGINEERING SERVICES P.E. No. 33868 W Robert Munroe CASSELBERRY, FLORIDA 407-830-6500 x� U b N JOB NUMBER: 6830F03 Y ISSUE DATE: 02/07/2020 W DRAWN BY: John Creamer CHECKED BY: Cory Abbott ►�;i, , `�.IjA: Bob Seekamp s �� • C1t r N ' Fire Alarm Shop Drawings y x BB i N M O F-4 O M m a4 CC4 Q x 3 4 5 6 7 8 9 10 11- 12 13 14 IAz 17 1 18 10 20 21 22 23 24 125 126 127 28 129 130 131 132 133 134 35 36 FA-5 O 3 4 5 6—r--7T8--9—-101213----T14----T---15T16---T--17-71819—r20----2122-23T24—r-25T2627r-28--29T30—-3132--33r-34T35T36 r N AM DYNAFIRE w P N N p Z C \J a Wireless DYNA E T I alarm Monitoring DYNAFIRE INC. PHONE (407) 830-6500 - FAX (407) 831-1347 109E Concord Drive CASSELBERRY, FLORIDA 32707 C E-MAIL: info@dynafire.com Qualifier: STEVEN HATCH STATE LICENSE # EF20000528 WEBSITE: WWW.DYNAFIRE.COM FIRE ALARM RISER NAC-2-Vl -001 NAC-2•V1 -002 NAC-2-V1-003 NAC-2-V1-004 NAC-2-V1-005 NAC-2-Vl -006 NAC-2-Vl -007 NAC-2-Vl -008 NAC-2-V1-009 NAC-2-V1-010 NAC-2-V1-011 NAC-2-Vl -012 NAC-2-Vl -013 NAC-2-Vl -014 NAC-2-V1-015 NAC-2-Vl -016 NAC-2-Vl -017 NAC-2-V1.018 NAC-2-Vl -019 NAC-2-V1-020 EOL NAC-2 15cd 15cd 75cd 15cd 15cd 15cd 15cd 15cd 15cd 15cd 15cd 15cd 15cd 15cd 155d 1 B^ 15cd 15cd 15cd 15cd 15cd NAC u �• u u ,, a 1 B 1 B� �r� NAC-2-V2-001 NAC-2-V2-002 NAC-2•V2-003 NAC-2-V2-004 NAC-2-V2-005 NAC-2•V2-006 NAC-2•V2-007 NAC-2-V2-008 NAC-2-V2-009 NAC-2-V2-010 B 15cd 15cd 15cd 15cd 15cd 95cd 95cd 95cd 15cd 15cd 0 1 B 1 B NAC-2-V2-011 EOL 15cd NAC-1-V2-001 NAC-1-V2-002 NAC-1-V2-003 NAC-1-V2-004 NAC-1-V2-005 NAC-1-V2-006 NAC-1-V2-007 NAC-1-V2-010 75cd 110cd 15cd 15cd 0 15cd 110cd 75cd 15cd 1 B NAC-1-V2-00 NAC-1-V2-0 1 B NAC-1-V2-011 EOL 15cd 30cd 15cd NAC—I-AUX1-0 NAC-1-AUX1-0 NAC-1-AUX1-0 NAC-1-AUX1-0 NAC— X1-0 NAC-1 -AUX1 -006 DH DH DH DH DH D DH NAC— 1-V4-001 NAC-1-V4-002 NAC-1-V4-003 NAC-1-V4-004 EOL i B 110cd 110cd 15cd 15cd 75 NAC-1-V3-001 NAC-1-V3-002 NAC-1-V3-003 NAC-1-V3-004 NAC-1-V3-005 NAC-1-V3.006 NAC-1 -V3-007 NAC-1-V3-008 NAC-1-V3-009 NAC-1-V3-010 NAC-1-V3-011 NAC-1-V3-012 EOL NAC-1 15cd 15cd 15cd 15cd 15cd 75cd 15cd 15cd 15cd 75cd 75cd 15cd NAC o 0 0 1 B B 1 B NAC-1-V1-001 NAC-1-V1-002 NAC-1 •V1-005 i B 15cd 15cd 15cd � o NAC-1 -V1-003 NAC-1-V1-004 1 B NAC-1-V1.006 EOL 15cd 15cd 15cd NAC-1-AUX2-0 NAC-1-AUX2-002 DH DH V1.001 V1-002 V1-003 V1-004 V1-005 V1.006 V1-007 V1.008 V1.009 V1-010 V1.011 V1-012 V1-013 V1-014 V1-015 V1.016 V1-017 EOL 1 e 15cd 0 15cd 15cd 15cd 15cd 0 15cd 15cd 15cd 0 15cd 15cd 15cd 15cd 15cd 15cd 15cd 15cd 15cd 0 1 B 1 B 1 B L1-M001 L1 -D001 L1-DO02 L1-D003 L1-D004 L1-D005 L1-M002 L1 •D006 L1-D007 L1 •D008 L1-D009 L1-M003 L1-DO10 L1-D011 L1-D012 L1-D013 L1-D014 L1-D015 L1-D016 L1-D017 L1-D018 = F t t t t F t t 2 F t t 2 t t t 2 1 t rfj--B 'tat 1 1 s V2-001 V2-002 V2-003 V2-004 V2-005 V2-006 V2-007 V2-008 V2-009 V2-010 V2-011 V2.012 V2-013 V2-014 V2-015 V2-016 V2-017 V2.018 V2.019 V2-020 E L 75cd 15cd 15cd 75cd 15cd 75cd 15cd 15cd 15cd 15cd 15cd 15cd 15cd 15cd 15cd 15cd 15cd 15cd 15cd 15cd i r2 p 14 O O O 1 B 1 B 1 B L1-M007 L1-D025 L1-M005 N AA F t t t F �L1029 t t ANN-001 L1-M008 L1-DO32 L1-D031 L1-D030 s L1 •D028 L1 •D027 L1-D026 L1-M006 L1-D024 L1-D023 L1 •D022 s L1-D021 L1-D020 L1 •D019 L1 •M004 L1-D066 L10065 L1 0064 L1 •D063 L1-D062 L1-M014 L1-D061 L1-D060 L1-D059 L1-D058 L1-D057 L1-D056 L1-D055 L1-D054 L1-D053 L1-D052 L1-D051 L1-D050 L1-M013 t t t t l F t i t j 1 s 2 s 2 � 2 s F 1s 1s 1s O 1s L1-M015 L1-D068 L1-0069 L1-D070 L1-M016 L1-D071 L1 -D072 L1-D073 L10074 L1-D075 L1-M017 2 F t t l t F L1-D067 1s 1s L1 •M018 p L1-M 019 L1-D076 pM L1-M020 L1-0077 L1-0078 L1-D079 L1 -D080 L1-M021 l M F 2 F s 1s L1-DO82 L1-D081 L1-M023 L1-M022 Q S t F MM 0 L1 •D033 L1 •D034 L1-M009 L1-D035 L1-D036 L1 •D037 L1-M010 L1 •M011 L1•D038 L1-M012 L1-D039 L1-D040 L1-D041 L1-D042 L1-D043 L1-D044 L1-D045 L1-D046 L1-D047 L1-D048 L1-D049 V R N 0 z u 0 0 i- a_ S e U 0 W 0 D � N O T LU o Q 04 o � C4 O U ce V DYNAFIRE, INC. ENGINEERING SERVICES P.E. No. 33868 w Robert Munroe CASSELBERRY, FLORIDA 407-830-6500 x U ro a a4 JOB NUMBER: 6830F03 Y b ISSUE DATE: 02/07/2020 4-4 DRAWN BY: John Creamer CHECKED BY: Cory Abbott CU rd PM: Bob Seekamp = � N0. ��.. �•Z Fire Alarm L Shop Drawings s d x N BB W" LV O O co co FAm6 H CCl f". Q .'L ' 3 14 5 6 7 8 9 10 11 1 114 15 17 119 21 122 123 24 25 27 128 29 30 31 132 133 34 135 36 26 18 20 12 13 16 - .. "i I ill 111,41 11 I'm_, dWk1411h.iA4:9 ilMll ul Mi. S I MI I..-&l'- ._ 1 141, I. i iL J 1 � i � �— I - �. I i - 11 f I. 15::. _ u 3 1 4 1 5 1 6 1 7 1 8 9 1 10T1 1T-12—r 13—i--14-7-15 i 16-- T---17----18—r--19 i 20—r-2122 r 23— I 24 1-25 26 27— —28T29 T---30T31----32T33-- 34--F---35 1 36 x N AIR:' tl C� Z O B DYNAFIRE DYNA ET I Alarms Alarm Monitoring D E F C SYSTEM OUTPUTS D FIRE FACP ANNUNCIATION NOTIFICATION REQUIRED FIRE SAFETY CONTROL ALARM SYSTEM GPI°� �O\vP �VP�°� E P���O Q ��P QP �� P�\° \�O� �Qy �O INPUT/OUTPUT °,, �P� ��° �..° \°��� \°�P� �,°� MATRIX �� ,� �o �o`t �O ��° P� �� AS) J� . 4� S JO�� �\,`� P�J P� PAP �JQ �JQ �q ��q OQ, �JP �� q� ��q J J� F c� J & 'e<v q� 611 QJ5 Gq� PJO GOB �JO ,�0� pQc' G�P� JQ`Q' AV SYSTEM INPUTS G A B C D E F Q H I J K L M N O P Q R 8 T U V 1 FIRE ALARM SYSTEM AC POWER FAILURE X X X 1 2 FIRE ALARM SYSTEM LOW BATTERY X X X 2 H 3 OPEN CIRCUIT X X X 3 4 GROUND FAULT X X X 4 5 NOTIFICATION APPLIANCE CIRCUIT SHORT X X X 5 I 6 BUILDING MANUAL PULL STATIONS X X X X X X X 6 7 AREA SMOKE DETECTORS X X X X X X X 7 8 DUCT DETECTORS X X X X X 8 9 SPRINKLER TAMPER SWITCH X X X X 9 10 AREA HEAT DETECTORS X X X X X X X 10 11 11 K 12 12 13 13 14 14 L 15 15 16 16 17 17 M 18 18 A B C D E F Q H I J K L M N O P O R 8 T U V N 0 P Q ANTENNA TYPE TO BE DETERMINED AT TIME R OF INSTALLATION *ANTENNA SHOWN AS AN EXAMPLE ONLY S ,ft 7788F WIRELESS RADIO 7744 INTELLIPRO ++ CONNECTION ® () TO RADIO 11F o T 9 9 9-,Al D `0 —JAL— 34 b. 0.5 i TO FRCP DIALER yn 120 VAC e FAIL SAFE O Q v CONNECTION TO FACP stT st AMBICCiRANsfCM1iP pM MFiW 10.0 VAC Iw'A Molt 7,5AH W Battery tT -9 X� ro ro 04 :v H pp 14 I' Yra 0fi6@0 BB i N M O w O M co i a4 H CC(a A x 23 t24 125 126 127 128 129 130 131 1 32 133 134 135 136 DYNAFIRE INC. PHONE (407) 830-6500 - FAX (407) 831-1347 109B Concord Drive CASSELSERRY, FLORIDA 32707 E-MAIL: info@dynafire.com Qualifier: STEVEN HATCH STATE LICENSE # EF20000528 WESSITE: WWW.DYNAFIRE.COM z 0 10— L) D ce z 0 z u O 0 � LL a U W 0 tN DYNAFIRE, INC. ENGINEERING SERVICES P.E. No. 33868 Robert Munroe N co M & 1k Cn L CL N CASSELBERRY, FLORIDA 407-830-6500 JOB NUMBER: ISSUE DATE: DRAWN BY: CHECKED BY: 11 6830F03 02/07/2020 John Creamer Cory Abbott Bob Seekamp Fire Alarm Shop Drawings FA-7 O 0 let!.