HomeMy WebLinkAbout39506 South AveCITY OF ZEPHYRHILLS GUNNER PAW PARK RESTROOM FACILITY BUILDING DATA: OCCUPANCY CLASSIFICATION: N/A CONSTRUCTION TYP: V B LOAD CAPACITGY: N/A FIRE PROTECTION RESIDENTIAL AND COMMERCIAL BUILDING DESIGNS 13821 U.S. HWY 98 BY PASS DADE CITY, FLORIDA 33523 OFFICE 352-523-2077 FAX 352-567-2070 N/A PLAN INDEX SHEET 131 : FLOOR PLAN DOOR SCHEDULE INTERIOR FINISH SCHEDULE SHEETS 1: FOUNDATION PLAN ROOF TRUSS PLAN ROOF SHEATHING DETAIL TRUSS BRACING DETAIL WALL SECTION DETAILS GENERAL CONSTRUCTION NOTES SHEET El: POWER PLAN LOAD CALCULATIONS ELECTRICAL RISER PANEL SCHEDULE ELECTRICAL LEGEND/ SCHEDULE Pl: SANITARY PLAN PLUMBING FIXTURE SCHEDULE ADA FIXTURE DETAILS ARKAY ENGINEERING INC. structural engineers 1958 E. Edgewood Drive, Lakeland FI 33803 Phone 663-688-6500 Fax 863-688-6551 State of Florida Certificate of Authorization E56341 Richard L 1Kiddeg P.E. - Florida License 3121B6 GENERAL NOTES: THIS BUILDING HAS BEEN DESIGNED TO CONFORM TO THE 2D10 FLORIDA BUILDING CODE ARKAY ENGINEERING, INC.; A REGISTERED, LICENSED, FLORIDA PROFESSIONAL STRUCTURAL ENGINEERING COMPANY; HAS APPLIED "RATIONAL ANALYSIS" FOR THE STRUCTURAL DESIGN OF THIS STRUCTURE. THE BUILDING ( INCLUDING ALL COMPONENTS AND CLADDINGS) SHALL BE DESIGNED FOR THE FOLLOWING SUPERIMPOSED LOADS: FLOORS: LIVE LOAD - 50 P.S.F. DEAD LOAD - 10 P.S.F. ROOF: LIVE LOAD ( TRUSS TOP CHORD) - 20 P.S.F. DEAD LOAD ( TRUSS TOP CHORD) - 10 P.S.F. DEAD LOAD ( TRUSS BOTTOM CHORD) - 10 P.S.F. ASSUMED TRUSS SELF WEIGHT ( DEAD LOAD) - 7 P.S.F. WIND: BUILDING IS DESIGNED TO CONFORM TO ASCE 7-10, CHAPTERS 26 THRU 31; PER 2010 FLORIDA BUILDING CODE SECTION 1609.1.1. VVINL) ut51Vry HSSUMF I IUNs: BUILDING EXPOSURE - B BUILDING RISK CATEGORY - II MEAN ROOF HEIGHT 30' OR LESS HEIGHT & EXPOSURE ADJUSTMENT COEFFICIENT = 1.0 ENCLOSED BUILDING INTERNAL PRESSURE COEFFICIENT = +/- 0AB WIND SPEED SHOWN AT THE BOTTOM RIGHT CORNER OF THIS SHEET ALL STRUCTURAL ELEMENTS, EXTERIOR WALLS AND INTERIOR WALLS SHALL BE TYPE V CONSTRUCTION PER FBC 602Z COMPONENT & CLADDING WIND LOADS ALL OTHER BUILDING ROOF OVERHANG COMPONENT ZONE LOADS LOADS 1 NIA +32.3/-35.3 2 -65.7 +32.3/-56.2 3 -110.6 +32.3/-89.0 4 N/A +35.3/-38.2 5 N/A +35.3/-47.2 SOIL BEARING & COMPACTION: THESE PLANS WERE DRAWN BASED UPON AN ALLOWABLE SOIL BEARING CAPACITY OF 2,000 P.S.F. (MINIMUM . THE CONTRACTOR/PROPERTY OWNER ARE RESPONSIBLE FOR VERIFYING THAT THE SOIL ON THE SITE IS PROPERLY PREPARED & COMPACTED SUCH THAT IT CAN SUPPORT A 2,000 P.S.F. FOUNDATION LOADING. ARKAY ENGINEERING, INC.; A REGISTERED, LICENSED, FLORIDA PROFESSIONAL STRUCTURAL ENGINEERING COMPANY; DESIGNED THESE FOUNDATIONS WITHOUT VISITING THE CONSTRUCTION SITE NOR PERFORMING ANY SOIL TESTING. ARKAY ENGINEERING, INC. SHALL NOT BE RESPONISIBLE FOR THE SITE SOILS ABILITY TO SUPPORT THE BUILDING LOADS. FOUNDATIONS & SLAB -ON -GRADE: BUILDING SITE SHALL BE SCRAPED TO REMOVE ALL ORGANIC MATERIALS WITHIN THE BUILDING AREA. ANY ADDITIONAL FILL PLACED ON THE BUILDING PAD AREA, SHALL BE COMPACTED SUCH THAT IT CAN ADEQUATELY SUPPORT A 2,000 P.S.F. FOUNDATION LOADING. SLAB SHALL BE PLACED OVER A 6 MIL VAPOR BARRIER ON CLEAN, ADEQUATELY COMPACTED AND TERMITE POISONED SOIL. CONCRETE UTILIZED IN THE FOUNDATIONS AND SLABS SHALL HAVE A MINIMUM 28 DAY COMPRESSIVE STRENGTH OF 2,500 P.S.I. REINFORCING STEEL SHALL BE GRADE 40 MINIMUM AND IDENTIFIED IN ACCORDANCE WITH ASTM A-615. LAP SPLICES, WHERE REQUIRED, SHALL BE A MINIMUM OF 25" FOR #5 REBAR, 30" FOR #6 REBAR & 35" FOR #7 REBAR. PLANS ARE ENGINEERED FOR A MAXIMUM STEMWALL HEIGHT OF 4 COURSES ( AFTER FINAL SITE GRADING) . THE CONTRACTOR OR BUILDING OWNER SHALL DETERMINE THE EXACT STEMWALL HEIGHT BASED UPON SITE CONDITIONS PRIOR TO POURING THE FOUNDATION AND CONTACT ARKAY ENGINEERING WHEN MORE THAN 4 COURSES ARE REQUIRED. A FOUNDATION SURVEY SHALL BE PERFORMED AND A COPY OF THE SURVEY SHALL BE ON THE SITE FOR THE BUILDING INSPECTORS USE, OR ALL PROPERTY MARKERS SHALL BE EXPOSED AND A STRING STRETCHED FROM MARKER TO MARKER TO VERIFY THE REQUIRED BUILDING SETBACKS. 1/2" CDX ROOF SHEATHING NAILED PER ROOF SHEATHING DETAIL WITH 8D RS NAILS. COVER WITH #30 FELT.INSTALL MASTER RIB 26 GA PAINTED STEEL ROOFING OR EQUAL AS PER MANUFACTURES SPECIFICATIONS SECURE ALL ROOF TRUSSES TO BLOCK WALLS USING SIMPSON HETA20 TRUSS STRAPS, FILL NAIL HOLES WITH 10DX 1 1/2' NAILS TOP OF BLOCK WALL 8' 4" I I 1' 4" I_ 2' 0" 2X4 WOOD SUB FASCIA WITH OVERHANG CANTILEVER ALUMINUM FASCIA, DRIP AND SOFFIT MATERIALS NO INSULATION IN WALLS 0 60 STRUCK JOINT PAINTED BLOCK WALLS ON EXTERIOR BUILDING FINISH FLOOR 0' 4" APPROXIMATE FINAL GRADE 0' 0" co BOTTOM OF FOOTING SOIL TERMITE TREATMENT: PER FBC 2304.11 TERMITE PROTECTION SHALL BE PROVIDED BY REGISTERED TERMITICIDES, INCLUDING PESTICIDES APPLIED TO SOIL, OR WOOD, BAITING SYSTEMS, OR OTHER APPROVED PROTECTION LABELED FOR USE AS A PREVENTATIVE TREATMENT TO NEW CONSTRUCTION. A "CERTIFICATE OF COMPLIANCE" SHALL BE ISSUED TO THE BUILDING DEPARTMENT BY A LICENSED PEST CONTROL COMPANY BEFORE A "CERTIFICATE OF OCCUPANCY" WILL BE ISSUED. THE CERTIFICATE SHALL STATE "THE BUILDING HAS RECEIVED A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN TERMITES. THE TREATMENT IS IN ACCORDANCE WITH THE RULES AND LAWS OF THE FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES." INITIAL SOIL POISONING TREATMENT SHALL BE DONE AFTER ALL EXCAVATION, BACKFILLING & COMPACTION ARE COMPLETE ANY SOIL DISTURBED AFTER THE INITIAL TREATMENT SHALL BE RE -TREATED ( INCLUDING ANY BOXED OR FORMED AREAS) - BOXED AREAS IN THE CONCRETE SLAB FOR INSTALLATION OF TRAPS SHALL BE MADE WITH PERMANENT METAL OR PLASTIC FORMS. PERMANENT FORMS MUST BE OF AN ADEQUATE SIZE & DEPTH TO ELIMINATE ANY DISTURBANCE OF THE SOIL AFTER THE INITIAL TREATMENT. A MINIMUM 6 MIL VAPOR BARRIER MUST BE INSTALLED TO PROTECT AGAINST RAINFALL DILUTION. IF RAINFALL OCCURS BEFORE VAPOR BARRIER PLACEMENT, RE -TREATMENT SHALL BE REQUIRED ANY CONCRETE OVERPOUR, MORTAR OR STUCCO MATERIALS ALONG THE FOUNDATION PERIMETER MUST BE REMOVED PRIOR TO EXTERIOR SOIL TREATMENT EXTERIOR SOIL TREATMENT MUST BE APPLIED UNDER ALL EXTERIOR CONCRETE OR GRADE WITHIN 12 INCHES OF THE STRUCTURE SIDE WALLS AN EXTERIOR VERTICAL CHEMICAL BARRIER SHALL BE INSTALLED AFTER CONSTRUCTION IS COMPLETE ( INCLUDING LANDSCAPING AND IRRIGATION) . ANY SOILS DISTURBED AFTER THE VERTICAL BARRIER IS APPLIED, SHALL BE RE -TREATED. CONDENSATE AND ROOF DOWNSPOUTS SHALL DISCHARGE AT LEAST 12 INCHES AWAY FROM THE BUILDING SIDEWALLS AFTER ALL WORK IS COMPLETED, ANY LOOSE WOOD AND FILL MUST BE REMOVED FROM BELOW AND WITHIN 12 INCHES OF THE BUILDING. THIS SHALL INCLUDE ALL GRADE STAKES, TUB TRAP BOXES FORMS, SHORING AND ANY OTHER CELLULOSE CONTAINING MATERIALS. THE DISTANCE FROM THE EXTERIOR WALL COVERING ( EXCEPTIONS: PAINT AND DECORATIVE CEMENTITIOUS FINISHES LESS THAN 5/6 INCH THICK ADHERED DIRECTLY ONTO THE FOUNDATION WALL) AND FINAL EARTH GRADE SHALL NOT BE LESS THAN 6 INCHES TO ALLOW FOR INSPECTION FOR FUTURE TERMITE INFESTATIONS EXTERIOR WINDOWS & DOOR ASSEMBLIES: ALL EXTERIOR WINDOW & GLASS DOORS SHALL BE TESTED IN ACCORDANCE WITH ANSI/AMMA/NWWDA 101/IS2 STANDARDS AND BEAR AN AMMA OR WDMA LABEL IDENTIFYING THE MANUFACTURER, PERFORMANCE CHARACTERISTICS AND APPROVED PRODUCT TESTING ENTITY. ALL MULLIONS AND ADJACENT DOORIWINDOW ASSEMBLIES SHALL BE TESTED OR ENGINEERED TO TRANSFER 1.5 TIMES THE DESIGN LOADS TO THE ROUGH OPENING SUBSTRATE. INSTALL ALL WINDOW & DOOR ASSEMBLIES PER THE MANUFACTURERS ANCHORING RECOMMENDATIONS TO ACHEIVE THE DESIGN PRESSURES SPECIFIED. SAFETY GLAZING: THE FOLLOWING SHALL BE CONSIDERED SPECIFIC HAZARDOUS LOCATIONS FOR THE PURPOSES OF GLAZING PER THE FLORIDA BUILDING CODE, RESIDENTIAL - ( 1) GLAZING IN SWINGING DOORS, FIXED AND SLIDING PANELS OF SLIDING DOOR ASSEMBLIES. (2) GLAZING IN DOORS AND ENCLOSURES FOR HOT TUBS, WHIRLPOOLS, SAUNAS, STEAM ROOMS, BATHTUBS, AND SHOWERS. GLAZING IN ANY PORTION OF A BUILDING WALL ENCLOSING THESE COMPARTMENTS WHERE THE BOTTOM EDGE OF THE GLAZING IS LESS THAN 60 INCHES ABOVE THE DRAIN INLET. (3) GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL ADJACENT A DOOR WHERE THE NEAREST VERTICAL EDGE IS WITHIN A 24 INCH RADIUS OF THE DOOR IN A CLOSED POSITION AND WHOSE BOTTOM EDGE IS LESS THAN 60 INCHES ABOVE THE FINISHED FLOOR OR WALKING SURFACE. (4) GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL, OTHER THAN THOSE LOCATIONS DESCRIBED IN ITEMS (2) AND (3) ABOVE. THAT MEETS ALL OF THE FOLLOWING CONDITIONS: A) EXPOSED AREA OF AN INDIVIDUAL PANE GREATER THAN 9 SQ. FT. B) BOTTOM EDGE LESS THAN 18 INCHES ABOVE THE FLOOR. C) TOP EDGE GREATER THAN 36 INCHES ABOVE THE FLOOR. D) ONE OR MORE WALKING SURFACES WITHIN 36 INCHES HORIZONTALLY OF THE PLANE OF THE GLAZING. ENGINEERED ROOF TRUSSES NO INSULATION IN ATTIC 4X8 JAMES HARDI 8" VERTICAL GROOVE SHEETS APPLIED TO BOTTOM OF ROOF TRUSSES WITH 8D NAILS 8' OC (TYP) SINGLE COARSE KNOCK OUT LINTEL BLOCK COARSE AT TOP OF WALL WITH 145 HORIZONTAL REBAR TIED TO ALL VERTICAL RODS, POUR SOLID WITH 3000 PSI CONCRETE _ 8" PRECAST LINTEL OVERALL OPENINGS IN WALL (TYP) STRUCK JOINT PAINTED BLOCK WALLS ON INTERIOR #5VERTICAL REBAR FROM FOOTINGS TO TOP OF WALL AT LOCATIONS SHOWN ON FLOOR AND FOUNDATION PLAN TIED TO ALL REBAR IN LINTEL. AND FOOTINGS. POUR CELL SOLID WITH 3000 PSI CONCRETE. ALL REBAR LAP TO BE MINIMUM 25" 4" 3000 PSI CONCRETE OVER CLEAN COMPACT TERMITE TREATED SOIL. COVER WITH 6 MILL VISQUEEN AND USE 616 10/10 WIRE MESH 16"X12" 3000 PSI CONCRETE FOOTING WITH WITH 245 REBAR ON CHAIRS USE 1 SIMPSON HETA20 STRAP AT ONE SIDE OF ALL ROOF TRUSSES AT BLOCK WALL. FILL NAIL HOLES WITH 10DX 1/2" NAILS. 12' 0" 2' 0" I I I / I I I I /1 I 1/2" CDX ROOF SHEATHING NAILED PER ROOF SHEATHING DETAIL WITH 8D RS NAILS. COVER WITH #30 FELT.INSTALL MASTER RIB 26 GA PAINTED STEEL ROOFING OR EQUAL AS PER MANUFACTURES SPECIFICATIONS SECURE ALL ROOF TRUSSES TO BLOCK WALLS USING SIMPSON HETA20 TRUSS STRAPS, FILL NAIL HOLES WITH 10DX 1 1/2' NAILS 0 co TOP OF BLOCK WALL 8' 4" _a I 1' 4" 2X4 WOOD SUB FASCIA WITH OVERHANG I ALUMINUM FASCIA, DRIP AND SOFFIT MATERIALS NO INSULATION IN WALLS STRUCK JOINT PAINTED BLOCK WALLS ON EXTERIOR BUILDING FINISH FLOOR 0' 4" APPROXIMATE FINAL I O BOTTOM OF FOOTING CANTILEVER ROOF LINE 00 r ENGINEERED ROOF TRUSS PLAN 1/4" = 1' 0' 2X4 CROSS -BRACING @ RIDGE 20'-0" MAX mi mm1�11 SEE TRUSS SYSTEM ENGINEERING DRAWINGS FOR ANY ADDITIONAL BRACING OR CROSS BRACING REQUIREMENTS REQ. MINIMUM TRUSS BRACING ENGINEERED ROOF TRUSSES NO INSULATION IN ATTIC 4X8 JAMES HARDI 8" VERTICAL GROOVE SHEETS APPLIED TO BOTTOM OF ROOF TRUSSES WITH BD NAILS 8" OC (TYPj SINGLE COARSE KNOCK OUT LINTEL BLOCK COARSE AT TOP OF WALL WITH 1-#5 HORIZONTAL REBAR TIED TO ALL VERTICAL RODS, POUR SOLID WITH 300D PSI CONCRETE 6" PRECAST LINTEL OVER ALL OPENINGS IN WALL (TYP) STRUCK JOINT PAINTED BLOCK WALLS ON INTERIOR #SVERTICAL REBAR FROM FOOTINGS TO TOP OF WALL AT LOCATIONS SHOWN ON FLOOR AND FOUNDATION PLAN TIED TO ALL REBAR IN LINTEL. AND FOOTINGS. POUR CELL SOLID WITH 3000 PSI CONCRETE. ALL REBAR LAP TO BE MINIMUM 25' 4" 3000 PSI CONCRETE OVER CLEAN COMPACT TERMITE TREATED SOIL. COVER WITH 6 MILL VISQUEEN AND USE 616 10110 WIRE MESH 16"X12" 3000 PSI CONCRETE FOOTING WITH WITH 245 REBAR ON CHAIRS 1' 0" �6" WALL SECTION DETAIL S-2 #5 VERTICAL RODS FROM FOOTINGS BELOW TO TOP OF WALL. PLACED AT ALL CORNERS, EACH SIDE OF ALL OPENINGS AND SPACED MAXIMUM VOlt OC TOP/BOTTOM CHORD GABLE 7 END BRACING @ 48" O.C. MAX FOR THE FIRST 4 ROWS OF TRUSSES ( MIN 2X4) W J Q 0 CONT. BOTTOM CHORD BRACING (1"x4" MIN) @ 10'-0" MAX. i t 12' 0" 5' 0" --------I�li----------------- li it li it li it li it Ali it I; ,I I II 11 I) II I I I I II I. I 4" CONCRETE I i I SIDEWALK 3' 4" '14" li il�li it I I I I I------- ---_-_ -- I I I I L —— — — J I----------------------- I II ■I� S II II II I I FOUNDATION PLAN 1/4" = 1' 0' NOTE: SEE SANITARY PLAN FOR PLUMBING FIXTURE LOCATIONS 51-10„ ROOFEDGE 0 yiA 22 c1<1 q O Q`Ae O O O I O GABLE END PARTIAL ROOF PLAN ZONE O 8dRING SHANK NAILS AT 6" Q.C. AT EDGES 8dRING SHANK NAILS AT 12" O.C. INTERMEDIATE ZONES 2a O 8dRING SHANK NAILS AT 6" O.C., 4" O.C. AT ROOF EDGES, RIDGE LINE, OR GABLE ENDWALL NOTE: END JOINTS FOR SHEATHING SHALL BE STAGGERED AND OCCUR OVER A FRAMING MEMBER. ROOF SHEATHING NAILING NOT TO SCALE ENGINEERED ROOF TRUSSES NO INSULATION IN ATTIC 4X8 JAMES HARDI 8" VERTICAL GROOVE SHEETS APPLIED TO BOTTOM OF ROOF TRUSSES WITH BD NAILS 8" OC (TYP) SINGLE COARSE KNOCK OUT LINTEL BLOCK COARSE AT TOP OF WALL WITH 145 HORIZONTAL REBAR TIED TO ALL VERTICAL RODS, POUR SOLID WITH 3000 PSI CONCRETE _ 8" PRECAST LINTEL OVER ALL OPENINGS IN WALL (TYP) STRUCK JOINT PAINTED BLOCK WALLS ON INTERIOR OF EACH SIDE #5VERTICAL REBAR FROM FOOTINGS TO TOP OF WALL AT LOCATIONS SHOWN ON FLOOR AND FOUNDATION PLAN TIED TO ALL REBAR IN LINTEL. AND FOOTINGS. POUR CELL SOLID WITH 3000 PSI CONCRETE. ALL REBAR LAP TO BE MINIMUM 25" 4" 3000 PSI CONCRETE OVER CLEAN COMPACT TERMITE TREATED SOIL. COVER WITH 6 MILL VISQUEEN AND USE 6/610/10 WIRE MESH 16"X12" 3000 PSI CONCRETE FOOTING WITH WITH 245 REBAR ON CHAIRS �6" WALL SECTION DETAIL S-3 NOT TO SCALE 00 r 0 z w w Q C9 ARKAY ENGINEERING INC. STRUCTURAL ENGINEERS RICHARD L. KIDDEY P.E. FLORIDA LICENSE NUMBER 37296 I HERBY CERTIFY THAT THESE PLANS AND SPECIFICATIONS WERE PREPARED BY ME OR UNDER MY DIRECT SUPERVISION ARE IN COMPLIANCE WITH CHAPTER 16, SECTION 1609 OF THE FLORIDA BUILDING CODE 2010 AND ASCE 7-10 FOR 137 MPH WIND ZONE RISK CATEGORY II W Q a z O W } r � � m cfl cq M�gtJ z1L L IJ_ so z c do Z Q) �e 0 1 lu >L Q p E ui 41 t! Q- 2 O UM 3 tM UJ � ca jhatoa d' M V_ m Nr •- A g Z `- Z m a o 0 I— J U U— 2 cn O T� i ` v / W DC ^= W N � Q Q I— U n. W Z Z r� V TOTAL AREA 176 SQ. FT. WALL SECTION DETAIL S-1 NOT TO SCALE NOT TO SCALE S1 ARKAY # TANKLESS WATER HEATER LOCATION HEATER LOCATION ELECTRICAL PLAN 1 /411 = 1' of 100 AMP 24 CIR TYPICAL PANEL 1 WALL PACK LIGHT/ TIMER 1 P20 2 STORAGE LIGHTS 1 P20 3 RESTROOM LIGHTS & FAN 1 P20 4 INSTANT HOT WATER / LAV 1 P20 5 INSTANT HOT WATER / MOP SK 1 P20 6 GFI RECEPTACLE 1 P20 7 EMERGENCY LIGHTS 1P20 8 SPACE 9 SPACE 10 SPACE 11 SPACE 12 SPACE 13 SPACE 14 SPACE 15 SPACE 16 SPACE 17 SPACE 18 SPACE 19 SPACE 20 SPACE 21 SPACE 22 SPACE 23 SPACE 24 SPACE LOAD CALCULATIONS LOAD DEMAND FACTOR TOTALS LIGHTING 176 X 3 528 RECPTS 1 X 180 180 TANKLESS WATER HEATERS 2 @ 360 720 TOTAL 1428 1428 VA 208 VOLTS 6.9 AMPS ELECTRICAL NOTES 1. All work to be done in accordance with all current national and local codes and ordinances. 2. Notify Engineer of any discrepancies between these drawings and the actual field conditions. Obtain clarifications from the Engineer or Owners prior to commencing work. 3. Contractor will visit site prior to bidding, no allowances for any extra expenses will be granted as a result of not visiting site. 4. Wire to be THHN/THWN Copper, min. size 14 AWG, unless shown otherwise. 5. RACEWAYS: RIGID STEEL CONDUIT: full weight galvanized threaded pipe, EMT CONDUIT: compression fittings, PVC: schedule 40, all as allowed by local codes. Separate raceways shall be used for each voltage system. 6. Any installation conflict with other trades shall be brought to the attention of the Engineer for clarification before proceeding. 7. Contractor will verify location of equipment and connect as required for clearances and connections. 8. All ourdoor electrical equipment to be NEMA 3R rated. LIGHTING & ELECTRICAL LEGEND A & O LITHONIA LB 1OX48 2 LAMP 110V GROUND BOSCH GL 5 WRAP FLUORESCENT FIXTURE FAULT OUTLET ARISTON 2 1/2 GALLON TANKLESS WATER HEATER BI 120V 1500 WATTS HE LITHONIA MNSB 132 L T6 2 LAMP FLUORESCENT 100 CFM FIXTURE NUTONE 765 HL EXHAUST FAN O PANEL $MS MOTION OCCUPANCY SENSOR SWITCH STANDARD SWITCH METER m EMERGENCY LIGHT LITHONIA TWAC WITH BATTERY B.U. MINI WALL PACK 3- #3 THNN 1- k3 N G FOOTER STEEL CONCRETE ENCASED"UFER" ELECTRODE REQUIRED PER CURRENT N.E.C. AND MUST BE INSPECTED PRIOR TO CONCRETE PLACEMENT ELECTRICAL RISER DIAGRAM NOT TO SCALE SINGLE PHASE BREAKER PANEL MAIN GROUND ROD 54" MIN TOILET 18" MIN 18" MIN —24" MIN PAPER F 1/ HOLDER 42" MIN : LAY i 1 z CLEAR FLOOR yj SPACE HANDICAP TOILET DETAIL ----- --- 60" MIN GRAB BARS A GRAB BAR SHALL BE PROVIDE, LOCATED 33" INCHES FROM AND PARALLEL TO THE FINISHED FLOOR. MEASURED VERTICALLY TO THE TOP OF THE RAIL WITH VARIATION OF NOT MORE THAN 1/2 INCH AND: I, SHALL HAVE AN OUTSIDE DIAMETER OF 1 V2 INCHES 2. SHALL PROVIDE 1 112 INCHES OF CLEARANCE BETWEEN THE RAIL AND THE WALL 3. SHALL BE SO DESIGNED AND SUPPORTED AS TO WITHSTAND A LOAD OF NOT LESS THAN 250 LBS APPLIED AT ANY POINT, DOWNWARD OR HORIZONTALLY. 4. SHALL BE CONTINUOUSLY GRASPABLE ALONG THE ENTIRE LENGTH. SPECIAL NOTE: GRAB BAR MEETING THE APPLICABLE ANSI STANDARDS ARE DEEMED TO BE IN COMPLIANCE WITH THE INTENT OF THE LAW WHETHER CENTER SUPPORTS EXIST OR NOT. S. SHALL BE AT LEAST 42 INCHES LONG AND SHALL BE CENTERED AT THE LEADING EDGE OF THE WATER CLOSET. ------------- ---- 6" MAX, ----'-- XX TOE CLEARANCE i z Q I I I I I I I I I I rt" MAX LAV DEPTH B" MIN KNEE CLEARANCE HANDICAP SINK DETAIL SINK 1. SINK SHALL BE MOUNTED WITH THE COUNTER OR RIM NO HIGHER THAN 34" FROM THE FINISH FLOOR. EACH SINK SHALL BE MINIMUM OF 6 1/2" DEEP, 2, CLEAR FLOOR SPACE RESTROOMS SHALL HAVE AN UNOBSTRUCTED SPACE OF AT LEAST 60" IN DIAMETER OR 52" BY Yl" FINISH INSIDE DIMENSIONS ADJACENT TO THE LAVATORY AREA, SUCH CLEAR FLOOR SPACE SHALL ADJOIN OR OVERLAP AN ACCESSIBLE ROUTE AND SHALL EXTEND A MAXIMUM OF 13" UNDERNEATH THE LAVATORY OR SNK PLUMBING FIXTURE SCHEDULE SLOAN OPTIMA FAUCET ETF-80 LAVATORY KOHLER MODEL K-2030-0 WHITE CHROME FINISH SUPPLY AND DRAIN PIPING TO HAVE TAMPER PROOF SHIELD UNDER SINK BOSCH GLS ARISTON 2 1/2 TO BE INSTALLED IN STORAGE TANKLESS GALLON AREA BEHIND LAVATORY WATER HEATER WATER CLOSET KOHLER MODEL K-4368-0 SLOAN MANUAL FLOOR MOUNT ADA FLUSHOMETER 110 SLOAN ROYAL EXPOSED URINAL KOHLER MODEL K-4904-ET-0 FLUSHOMETER MODEL 180 WALL MOUNT VERITEK CHROME FAUCET TO FIT MOP SINK SOLID MOLDED TUB TUB WITH WATER HOSE MANUFACTURE TO BE ADAPTER DETERMINED ELECTRICAL SPECIFICATIONS 1.1 SCOPE A. WORK INCLUDED: Include the following Work in addition to items normally part of this Section: 01 Wiring for lighting and power. 02 Installation of lighting fixtures with lamps. 03 Lighting panelboards and distribution panelboards. 04 Connection of equipment shown. 05 Control wiring. 06 Disconnection and removal of existing fixtures and wiring not to be reused. 1.2 MINIMUM COMPLIANCE STANDARDS A. All work shall be done in accordance with the requirements of the following: 01 Latest adopted issue of the National Electrical Code, NFPA 70. 02 Other applicable NFPA Codes. 03 Regulation of local authorities having jurisdiction. B. Furnish and install all labor, material and equipment and services necessary for complete and safe installation of the electrical system indicated on the drawings and noted in the specifications hereinafter. Electrical systems and equipment shall in general include the following: 01 General provisions for electrical work. 02 Wiring, distribution equipment and devices. 03 Lighting fixtures and lamps. 04 Grounding system. 1.3 GENERAL PROVISIONS FOR ELECTRICAL WORK A. DRAWINGS: Electrical drawings considered diagrammatic and indicate general arrangement of work and systems. Refer to other drawings to verify location of equipment, etc. Check drawings of other trades to verify exact space condition or underground lines. Drawing Scales prohibit the indication of all offsets, fittings and accessories required, however these items will be provided by this subcontractor at no extra cost to the owner. B. QUALITY OF MATERIALS: New, best of their respective kind, free from defects, and listed by Underwriter's Laboratories, Inc. or bearing their label. C. SHOP DRAWINGS: Submit four (4) copies of shop drawings for lighting fixtures and panelboards. Obtain approval before equipment is ordered, built or installed. D. EXCAVATION AND BACKFILLING: Excavate, backfill and restore surfaces for all electrical work. E. Visit site and inspect existing facilities before bid in order to ensure proper evaluation of working conditions and location of existing equipment. 1.4 WIRING, DISTRIBUTION EQUIPMENT AND DEVICES A. CONDUCTORS: Copper, in accordance with ASTM Standards, size references AWG. Conductors No. 10 and smaller size solid, No. 8 and larger stranded. Insulation of conductor thermoplastic, type THHN (min. size: No. 12) any wire installed outside, underground, in slabs, or exposed to moisture shall have THWN insulation. B. RACEWAYS: RIGID STEEL CONDUIT, full weight pipe galvanized, threaded, and minimum 112 inch except as noted or required for wiring. ELECTRICAL METALLIC TUBING (EMT), thin wall pipe, galvanized, threadless, comression fittings, and minimum 1/2" except as noted or required for wiring. FLEXIBLE STEEL CONDUIT, continuous singlestrip, galvanized, and minimum 1/2" size except as noted or required for wiring. PVC CONDUIT, heavy duty type, size as indicated. Type AC or MC cable where permitted. Separate raceways shall be used for each voltage system. C. DISCONNECT SWITCHES: General Duty, horsepower rated for motor loads 600 or 250 volt rating, fused or non -fused as noted; number of poles as indicated, cover Interlocked with switch. Enclosure NEMA 1 for indoor use and NEMA 3R for weatherproof applications. Switch to be Square "D" or equal. E ALL WATER AND SANITARY PIPING TO BE EXPOSED AND ACCESSIBLE FROM THIS SIDE OF MASONRY WALL SANITARY PLAN 1 /411 = 1' 0' PIPE NOTE: SANITARY PIPING TO BE SCHL 40 PVC COLD AND HOT WATER LINES TO BE CPVC OR EQUAL D. CIRCUIT BREAKERS: Molded case, thermal -magnetic quick -make, quick -break, bolt -on type with manually operated insulated trip -free handle. Multi -pole types with internal common trip bar. Terminals suitable for copper or aluminum conductors. Interrupting capacity minimum 10,000 RMS symmetrical amperes circuit breakers to be Square "D" or equal, type as required. E. PANELBOARDS: Voltage, phasing and ampere ratings as indicated, circuit breaker type as indicated, busbars of hard drawn copper, minimum 98% conductivity, galvanized steel back box, door and trim. All corners lapped and welded, hardware chrome plated with flush lock and catch. Hinges semi - concealed, 5 knuckle steel with nonferrous pins, 180 degree openings. Minimum gutter space 5- 3/4" sides, top and bottom. Increase size where required by code. Directory holder complete with clear plastic transparent cover indicating typewritten list of feeder cables, conduit sizes, circuit numbers, outlets of equipment supplied, and their location. Circuit breaker type panelboards to be Square "D" type NQOD or I -Line, or equal. A plastic label shall be located on exterior of panelboard identifying the system voltage, phase, and current rating. F. WIRING DEVICES: All devices the product of the same manufacturer. Wall switches singlepole, 20 ampere, 120 volt. Wall switches three-way, 20 ampere, 120 volt. Receptacles duplex, 2-wire; 3 pole grounded, 20 ampere, 120 volt. G. DEVICE PLATES: Provide for all outlets where devices are installed. Provide engraved marking for special outlets. Provide blank plates for empty or future outlet boxes. DEVICE AND DEVICE PLATES COLORS TO BE VERIFIED WITH INTERIOR DESIGNER AND OWNER. 1.5 LIGHTING FIXTURES AND LAMPS A. Furnish and install complete system of lighting fixtures, lamps, accessories and supports as specified and indicated. Submittals of equal quality are allowed. 1.6 GROUNDING SYSTEM A. EQUIPMENT: Ground non -current carrying metal parts of panelboard, raceways and all lighting fixtures. All conduits shall have equipment grounding conductors. 1.7 INSTALLATION A. Secure all supports to building structure. Support horizontal runs of metallic conduit not more than 10 feet apart. Run exposed raceways parallel with or at right angles to walls. B. Pass raceways over water, steam or other piping when pull boxes are not required. No raceway within 3 inches of steam or hot water pipes, or appliances, except crossings where raceway shall be at least 2 inches from pipe cover. C. Cut conduit ends square, ream smooth. Paint male threads of field threaded conduit with graphite base pipe compound. Draw up tight with conduit couplings. D. Leave wire sufficiently long to permit making final connections. In raceways over 50 feet in which wiring is not installed, furnish pull wire. E. Verify locations of outlets and switches. F. Support panel, junction and pull boxes independently to building structure with no weight bearing on conduits. G. Connect conduit to motor conduit terminal boxes with flexible conduit; minimum 18 inches in length and 50% slack. Do not terminate in or fasten raceways to motor foundation. H. Contractor to remove and salvage all abandoned electrical equiment. I. This contractor shall warrant all labor and materials for one year from date of final written acceptance. ARKAY ENGINEERING INC. STRUCTURAL ENGINEERS RICHARD L. KIDDEY P.E. FLORIDA LICENSE NUMBER 37296 1 HERBY CERTIFY THAT THESE PLANS AND SPECIFICATIONS WERE PREPARED BY ME OR UNDER MY DIRECT SUPERVISION ARE IN COMPLIANCE WITH CHAPTER 16, SECTION 1609 OF THE FLORIDA BUILDING CODE 2010 AND ASCE 7-10 FOR 137 MPH WIND ZONE RISK CATEGORY II Z� z 0" z V1 W A C r- 1 Comm Cq to* o� ma�iii Z IL X L J IL as z c _o 0FL z�>JJJ LJ 01T go w ILL "_J 1i_ ) W d 0 z O W W W co CV N � �CC m r G Z w ~ O Z m p p O i' J U Q U. 2 Ct) O O cl) = UJ N LL Q Oa L) LU Z Z /D V TOTAL AREA 176 SQ. FT. E1 P1 ARKAY # 29 GA MASTER RIB EEL ROOF TOP OF BLOCK WALL 8' 0" BUILDING FINISH FLOOR 0' 0" 0 FRONT ELEVATION 1/411= 1' 0' RIGHT ELEVATION 1/4" = 1' 0' REAR ELEVATION 1/411= 1' 0' 29 GA MASTER RIB LEFT ELEVATION 1/4" = 1' 0' DOOR AND HARDWARE SCHEDULE PLAN I.D. DOOR SIZE DOOR TYPE FRAME HARDWARE A 3'0"X6'8 1 3/4" HOLLOW METAL AMWELD WELDED METAL 3 EACH 4.5 26D 2 EACH BALDWIN 16 GA ROLLED STEEL OR AMWELD OR EQUAL SATIN CHROME 2000 264 SATIN CHROME EQUAL 1 EACH BALDWIN FINISH KICK PLATES 1 EACH BALDWIN 2115 264 SATIN CHROME 2115 264 SATIN CHROME PUSH PLATE PULL PLATE WITH 1 EACH 2552 264 SATIN CHROME PULL HANDLE 1 EACH SARGENT 1 EACH SCHLAGE MODEL 351 H.D. B561 SINGLE CYLINDER ALUMINUM FINISH DEADBOLT DOOR CLOSURE ALL WATER AND SANITARY PIPING TO BE EXPOSED AND ACCESSIBLE FROM THIS SIDE OF MASONRY WALL TANKL HEATS #5 VERTICAL RODS FROM FOOTINGS BELOW TO TOP OF WALL. PLACED AT ALL CORNERS, EACH - SIDE OF ALL OPENINGS AND SPACED MAXIMUM 4'0"OC 12' 0" 5101, 24" CANTILEVER ROOF LINE []111lIIIIC]IIIIII�Ii11C]IIIIIIIIII� -� — _ u ^1111�1I1C]i ►� �C]^ _ JSTORAGE �illlilllll[711111@11illC]IIIIIIIIIIC] TANKLESS WATER HEATER LOCATION FLOOR PLAN 1 /411 = 1' 0' ALL EXTERIOR WALLS ACT AS SHEAR WALLS FINISH SCHEDULE PLAN ID FLOOR WALL CEILING STRUCK JOINT EXPOSED JAMES HARDI 4X8 PANELS AMERICAN OLEAN CERAMIC TILE BLOCK WALL PAINTED PAINTED PORTER 900 INTERIOR RESTROOM AREA ENTITY GRAY UNIT EN-93 PORTER 900 INTERIOR EXTERIOR ENAMEL GLOSS EXTERIOR ENAMEL GLOSS COLOR TO BE CHOSEN COLOR TO BE CHOSEN STRUCK JOINT EXPOSED JAMES HARDI 4X8 PANELS STORAGE AREA BROOM FINISH CONCRETE BLOCK WALL PAINTED PAINTED PORTER 900 INTERIOR WITH CLEAR SEALER PORTER 900 INTERIOR EXTERIOR ENAMEL GLOSS EXTERIOR ENAMEL GLOSS COLOR TO BE CHOSEN COLOR TO BE CHOSEN STRUCK JOINT EXPOSED BLOCK WALL PAINTED EXTERIOR N/A PORTER 900 INTERIOR N/A EXTERIOR ENAMEL GLOSS COLOR TO BE CHOSEN ARKAY ENGINEERING INC. STRUCTURAL ENGINEERS RICHARD L. KIDDEY P.E. FLORIDA LICENSE NUMBER 37296 1 HERBY CERTIFY THAT THESE PLANS AND SPECIFICATIONS WERE PREPARED BY ME OR UNDER MY DIRECT SUPERVISION ARE IN COMPLIANCE WITH CHAPTER 16, SECTION 1609 OF THE FLORIDA BUILDING CODE 2010 AND ASCE 7-10 FOR 137 MPH WIND ZONE RISK CATEGORY II Z� Z m O ~ � m >. IOU 0 V� Ix tnZ 00 z N V F Zv, qy Q Iil A to X o fy Z �o 4 ri � � U w so0 Z LL L J u- s m c V t! Lu ol�u ui 0 z 0 w M N } � N M Z O z m p ¢ ❑ O F— _J U Q LL J_ O = Lu N LL Q O(L w Z Z 0 7 e. TOTAL AREA 176 SQ. FT. B1 ARKAY # I CITY OF ZEPHYRHILLS GUNNER PAW PARK RESTROOM FACILITY PLAN INDEX SHEET B1 : FLOOR PLAN DOOR SCHEDULE INTERIOR FINISH SCHEDULE SHEETS 1: FOUNDATION PLAN ROOF TRUSS PLAN ROOF SHEATHING DETAIL TRUSS BRACING DETAIL WALL SECTION DETAILS GENERAL CONSTRUCTION NOTES SHEET El: POWER PLAN LOAD CALCULATIONS ELECTRICAL RISER PANEL SCHEDULE ELECTRICAL LEGEND/ SCHEDULE Pl: SANITARY PLAN PLUMBING FIXTURE SCHEDULE ADA FIXTURE DETAILS SITE PLAN AND SITE ENGINEERING AS NEEDED PROVIDED BY CITY OF ZEPHYRHILLS I D E S I G N S INC RESIDENTIAL AND COMMERCIAL BUILDING DESIGNS 13821 U.S. HWY 98 BY PASS DADE CITY, FLORIDA 33523 OFFICE 352-523-2077 FAX 352-567-2070 RE J -< , , . J 0 12014 ry or LAf`481=-,)W 1NER BUILDING DATA: OCCUPANCY CLASSIFICATION: N/A. CONSTRUCTION TYP: V B LOAD CAPACITGY N/A FIRE PROTECTION: N/A 0*4 ARKAY ENGINEERING INC. structural engineers iS58 E. Edgewood Drive, Lakeland FI 33803 Phone 863-688-6500 Fax 863408840551 State of Florida Certificate of Authorization E156341 Richard L Kiddey P.E. - Florida Licence * 3�296 N GA MASTER RIB EL ROOF TOP OF BLOCK WALL 9_ 0" 0 BUILDING FINISH FLOOR 0' 0" FRONT ELEVATION 1/4" = 1' 0' RIGHT ELEVATION 1/4" = 1' 0' REAR ELEVATION 1/4" = 1' 0' LEFT ELEVATION 1 /4" = 1' 0' DOOR AND HARDWARE SCHEDULE PLAN I.D. DOOR SIZE DOOR TYPE FRAME HARDWARE A 3'0"X6'8 1 3/4" HOLLOW METAL AMWELD WELDED METAL 3 EACH 4.5 26D 2 EACH BALDWIN 16 GA ROLLED STEEL OR AMWELD OR EQUAL SATIN CHROME 2000 264 SATIN CHROME EQUAL FINISH KICK PLATES 1 EACH BALDWIN 1 EACH BALDWIN 21.15 264 SATIN CHROME 2115 264 SATIN CHROME PUSH PLATE PULL PLATE WITH 1 EACH 2552 264 SATIN CHROME PULL HANDLE 1 EACH SARGENT 1 EACH SCHLAGE MODEL 351 H.D. B561 SINGLE CYLINDER ALUMINUM FINISH DEADBOLT DOOR CLOSURE ALL WATER AND SANITARY PIPING TO BE EXPOSED AND ACCESSIBLE FROM THIS SIDE OF MASONRY WALL #5 VERTICAL RODS FROM FOOTINGS BELOW TO TOP OF WALL. PLACED AT ALL CORNERS, EACH - SIDE OF ALL OPENINGS AND SPACED MAXIMUM a'0"OC 12' 0" 5' 0" 24" CANTILEVER ROOF LINE []IIIIIIIIL]IIIII��I111C]Illllllllf� � � u � u - �lillllllll[]IIIII��IIIIC]/,IIIIIIIIIC] A— TANKLESS WATER HEATER LOCATION FLOOR PLAN 1/411= 1' 0' ALL EXTERIOR WALLS ACT AS SHEAR WALLS FINISH SCHEDULE PLAN ID FLOOR WALL CEILING STRUCK JOINT EXPOSED JAMES HARDI 4X8 PANELS AMERICAN GLEAN CERAMIC TILE BLOCK WALL PAINTED PAINTED PORTER 900 INTERIOR RESTROOM AREA FAWN GRAY Q06 PORTER 900 INTERIOR EXTERIOR ENAMEL SEMI GLOSS EXTERIOR ENAMEL SEMI COLOR TO BE CHOSEN GLOSS COLOR TO BE CHOSEN STRUCK JOINT EXPOSED JAMES HARDI 4X8 PANELS STORAGE AREA BROOM FINISH CONCRETE BLOCK WALL PAINTED PAINTED PORTER 900 INTERIOR WITH CLEAR SEALER PORTER 900 INTERIOR EXTERIOR ENAMEL SEMI GLOSS EXTERIOR ENAMEL SEMI COLOR TO BE CHOSEN GLOSS COLOR TO BE CHOSEN STRUCK JOINT EXPOSED BLOCK WALL PAINTED PORTER 900 INTERIOR EXTERIOR N/A EXTERIOR ENAMEL SEMI N/A GLOSS COLOR TO BE CHOSEN ARKAY ENGINEERINGINC. STR TURAL ENGINEERS; vi, I RICHARD . KIUDEY P.E. FLORIDA Li SENSE NUMBER 372P6 I HERBY CERTIFY THAT THE81i: PLANS AND SPECIFICATIONS WERE PREPARED BY ME OR UNDER MY DIRECT SUPERVISION ARE IN COMPLIANCE W;TH CHAPTER 16, SECTION 1609 OF THE FLORIDA BUILDING CODE 2010 AND ASCE 7-10 FOR 137 MPH WIND ZONE RISK CATEGORY II 1 1 I 1 I v f# 1 0 1 v) ► W ► A V m�IN u- i ° m U uj a Ul Z ul ems o � atha w Q 0 Z 1 1 U w w 3: cy) T— (o cM i- N m � � Z W Z F— m 0 J U Q LL c/) 2 O -17 W W N Q LL � O >- ;30- U � W Z Z D CD TOTALAREA 152 SQ. FT. 31 ARKAY # �q GENERAL NOTES: THIS BUILDING HAS BEEN DESIGNED TO CONFORM TO THE 2010 FLORIDA BUILDING CODE ARKAY ENGINEERING, INC.; A REGISTERED, LICENSED, FLORIDA PROFESSIONAL STRUCTURAL ENGINEERING COMPANY; HAS APPLIED "RATIONAL ANALYSIS" FOR THE STRUCTURAL DESIGN OF THIS STRUCTURE. THE BUILDING ( INCLUDING ALL COMPONENTS AND CLADDINGS) SHALL BE DESIGNED FOR THE FOLLOWING SUPERIMPOSED LOADS: FLOORS: LIVE LOAD - 50 P.S.F. DEAD LOAD - 10 P.S.F. ROOF: LIVE LOAD ( TRUSS TOP CHORD) - 20 P.S.F. DEAD LOAD ( TRUSS TOP CHORD) - 10 P.S.F. DEAD LOAD ( TRUSS BOTTOM CHORD) - 10 P.S.F. ASSUMED TRUSS SELF WEIGHT ( DEAD LOAD) - 7 P.S.F. WIND: BUILDING IS DESIGNED TO CONFORM TO ASC:E 7-10, CHAPTERS 28 THRU 31; PER 2010 FLORIDA BUILDING CODE SECTION 1609.1.1. COMPONENT & CLADDING WIND LOADS WIND DESIGN ASSUMPTIONS: BUILDING EXPOSURE - B BUILDING RISK CATEGORY - II MEAN ROOF HEIGHT 30' OR LESS HEIGHT & EXPOSURE ADJUSTMENT COEFFICIENT = 1.0 ENCLOSED BUILDING INTERNAL PRESSURE COEFFICIENT = +/- 0.18 WIND SPEED SHOWN AT THE BOTTOM RIGHT CORNER OF THIS SHEET ALL STRUCTURAL ELEMENTS, EXTERIOR WALLS AND INTERIOR WALLS SHALL BE TYPE V CONSTRUCTION PER FBC 602.5 ALL OTHER BUILDING ROOF OVERHANG COMPONENT ZONE LOADS LOADS 1 N/A +32.3/-35.3 2 -65.7 +32.3/-56.2 3 -110.6 +32.3/-89.0 4 N/A +35.3/-38.2 5 N/A +35.3/-47.2 SOIL BEARING & COMPACTION: THESE PLANS WERE DRAWN BASED UPON AN ALLOWABLE SOIL BEARING CAPACITY OF 2,000 P.S.F. (MINIMUM) . THE CONTRACTOR/PROPERTY OWNER ARE RESPONSIBLE FOR VERIFYING THAT THE SOIL ON THE SITE IS PROPERLY PREPARED & COMPACTED SUCH THAT IT CAN SUPPORT A 2,000 P.S.F. FOUNDATION LOADING. ARKAY ENGINEERING, INC.; A REGISTERED, LICENSED, FLORIDA PROFESSIONAL STRUCTURAL ENGINEERING COMPANY; DESIGNED THESE FOUNDATIONS WITHOUT VISITING THE CONSTRUCTION SITE NOR PERFORMING ANY SOIL TESTING. ARKAY ENGINEERING, INC. SHALL NOT BE RESPONISIBLE FOR THE SITE SOILS ABILITY TO SUPPORT THE BUILDING LOADS. FOUNDATIONS & SLAB -ON -GRADE: BUILDING SITE SHALL BE SCRAPED TO REMOVE ALL ORGANIC MATERIALS WITHIN THE BUILDING AREA.' ANY ADDITIONAL FILL PLACED ON THE BUILDING PAD AREA, SHALL BE COMPACTED SUCH THAT IT CAN ADEQUATELY SUPPORT A 2,000 P.S.F. FOUNDATION LOADING. SLAB SHALL BE PLACED OVER A 6 MIL VAPOR BARRIER ON CLEAN, ADEQUATELY COMPACTED AND TERMITE POISONED SOIL. CONCRETE UTILIZED IN THE FOUNDATIONS AND SLABS SHALL HAVE A MINIMUM 28 DAY COMPRESSIVE STRENGTH OF 2,500 P.S.I. REINFORCING STEEL SHALL BE.GRADE 40 MINIMUM AND IDENTIFIED IN ACCORDANCE WITH ASTM A-615. LAP SPLICES, WHERE REQUIRED, SHALL BE A MINIMUM OF 25" FOR #5 REBAR, 30" FOR #6 REBAR & 35" FOR #7 REBAR. PLANS ARE ENGINEERED FOR A MAXIMUM STEMWALL HEIGHT OF 4 COURSES ( AFTER FINAL SITE GRADING) . THE CONTRACTOR OR BUILDING OWNER SHALL DETERMINE THE EXACT STEMWALL HEIGHT BASED UPON SITE CONDITIONS PRIOR TO POURING THE FOUNDATION AND CONTACT ARKAY ENGINEERING WHEN MORE THAN 4 COURSES ARE REQUIRED. A FOUNDATION SURVEY SHALL BE PERFORMED AND A COPY OF THE SURVEY SHALL BE ON THE SITE FOR THE BUILDING INSPECTORS USE, OR ALL PROPERTY MARKERS SHALL BE EXPOSED AND A STRING STRETCHED FROM MARKER TO MARKER TO VERIFY THE REQUIRED BUILDING SETBACKS. 1/2" CDX ROOF SHEATHING NAILED PER ROOF SHEATHING DETAIL WITH 8D RS NAILS. COVER WITH #30 FELT. INSTALL MASTER RIB 26 GA PAINTED STEEL ROOFING OR EQUAL AS PER MANUFACTURES SPECIFICATIONS SECURE ALL ROOF TRUSSES TO BLOCK WALLS USING SIMPSON HETA20 TRUSS STRAPS, FILL NAIL HOLES WITH 10DX 1 1/2' NAILS TOP OF BLOCK WALL 8' 4" I V 4" 2' 0" 2X4 WOOD SUB FASCIA WITH OVERHANG CANTILEVER ALUMINUM FASCIA, DRIP AND VINYL SOFFIT MATERIALS NO INSULATION IN WALLS 0 ao STRUCK JOINT PAINTED BLOCK WALLS ON EXTERIOR BUILDING FINISH FLOOR 0' c APPROXIMATE FINAL GRADE 0 BOTTOM OF FOOTING SOIL TERMITE TREATMENT: PER FBC 2304.11 ' TERMITE PROTECTION SHALL BE PROVIDED BY REGISTERED TERMITICIDES, INCLUDING PESTICIDES APPLIED TO SOIL, OR WOOD, BAITING SYSTEMS, OR OTHER APPROVED PROTECTION LABELED FOR USE AS A PREVENTATIVE TREATMENT TO NEW CONSTRUCTION. A "CERTIFICATE OF COMPLIANCE" SHALL BE ISSUED TO THE BUILDING DEPARTMENT BY A LICENSED PEST CONTROL COMPANY BEFORE A "CERTIFICATE OF OCCUPANCY" WILL BE ISSUED. THE CERTIFICATE SHALL STATE "THE BUILDING HAS RECEIVED A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN TERMITES. THE TREATMENT IS IN ACCORDANCE WITH THE RULES AND LAWS OF THE FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES." INITIAL SOIL POISONING TREATMENT SHALL BE DONE AFTER ALL EXCAVATION, BACKFILLING & COMPACTION ARE COMPLETE ANY SOIL DISTURBED AFTER THE INITIAL TREATMENT SHALL BE RE -TREATED ( INCLUDING ANY BOXED OR FORMED AREAS) - BOXED AREAS IN THE CONCRETE SLAB FOR INSTALLATION OF TRAPS SHALL BE MADE WITH PERMANENT METAL OR PLASTIC FORMS. PERMANENT FORMS MUST BE OF AN ADEQUATE SIZE & DEPTH TO ELIMINATE ANY DISTURBANCE OF THE SOIL AFTER THE INITIAL TREATMENT. A MINIMUM 6 MIL VAPOR BARRIER MUST BE INSTALLED TO PROTECT AGAINST RAINFALL DILUTION. IF RAINFALL OCCURS BEFORE VAPOR BARRIER PLACEMENT, RE -TREATMENT SHALL BE REQUIRED ANY CONCRETE OVERPOUR, MORTAR OR STUCCO MATERIALS ALONG THE FOUNDATION PERIMETER MUST BE REMOVED PRIOR TO EXTERIOR SOIL TREATMENT EXTERIOR SOIL TREATMENT MUST BE APPLIED UNDER ALL EXTERIOR CONCRETE OR GRADE WITHIN 12 INCHES OF THE STRUCTURE SIDE WALLS AN EXTERIOR VERTICAL CHEMICAL BARRIER SHALL BE INSTALLED AFTER CONSTRUCTION IS COMPLETE ( INCLUDING LANDSCAPING AND IRRIGATION . ANY SOILS DISTURBED AFTER THE VERTICAL BARRIER IS APPLIED, SHALL BE RE -TREATED. CONDENSATE AND ROOF DOWNSPOUTS SHALL DISCHARGE AT LEAST 12 INCHES AWAY FROM THE BUILDING SIDEWALLS AFTER ALL WORK IS COMPLETED, ANY LOOSE WOOD AND FILL MUST BE REMOVED FROM BELOW AND WITHIN 12 INCHES OF THE BUILDING. THIS SHALL INCLUDE ALL GRADE STAKES, TUB TRAP BOXES FORMS, SHORING AND ANY OTHER CELLULOSE CONTAINING MATERIALS. THE DISTANCE FROM THE EXTERIOR WALL COVERING ( EXCEPTIONS: PAINT AND DECORATIVE CEMENTITIOUS FINISHES LESS THAN 5/8 INCH THICK ADHERED DIRECTLY ONTO THE FOUNDATION WALL) AND FINAL EARTH GRADE SHALL NOT BE LESS THAN 6 INCHES TO ALLOW FOR INSPECTION FOR FUTURE TERMITE INFESTATIONS EXTERIOR WINDOWS & DOOR ASSEMBLIES: ALL EXTERIOR WINDOW & GLASS DOORS SHALL BE TESTED IN ACCORDANCE WITH ANSI/AMMA/NWWDA 101/IS2 STANDARDS AND BEAR AN AMMA OR WDMA LABEL IDENTIFYING THE MANUFACTURER, PERFORMANCE CHARACTERISTICS AND APPROVED PRODUCT TESTING ENTITY. ALL MULLIONS AND ADJACENT DOORMINDOW ASSEMBLIES SHALL BE TESTED OR ENGINEERED TO TRANSFER 1.5 TIMES THE DESIGN LOADS TO THE ROUGH OPENING SUBSTRATE. INSTALL ALL WINDOW & DOOR ASSEMBLIES PER THE MANUFACTURERS ANCHORING RECOMMENDATIONS TO ACHEIVE THE DESIGN PRESSURES SPECIFIED. SAFETY GLAZING: THE FOLLOWING SHALL BE CONSIDERED SPECIFIC HAZARDOUS LOCATIONS FOR THE PURPOSES OF GLAZING PER THE FLORIDA BUILDING CODE, RESIDENTIAL - ( 1) GLAZING IN SWINGING DOORS, FIXED AND SLIDING PANELS OF SLIDING DOOR ASSEMBLIES. () GLAZING IN DOORS AND ENCLOSURES FOR HOT TUBS, WHIRLPOOLS, SAUNAS, STEAM ROOMS, BATHTUBS, AND SHOWERS. GLAZING IN ANY PORTION OF A BUILDING WALL ENCLOSING THESE COMPARTMENTS WHERE THE BOTTOM EDGE OF THE GLAZING IS LESS THAN 60 INCHES ABOVE THE DRAIN INLET. (3) GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL ADJACENT A DOOR WHERE THE NEAREST VERTICAL EDGE IS WITHIN A 24 INCH RADIUS OF THE DOOR IN A CLOSED POSITION AND WHOSE BOTTOM EDGE IS LESS THAN 60 INCHES ABOVE THE FINISHED FLOOR OR WALKING SURFACE. (4) GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL, OTHER THAN THOSE LOCATIONS DESCRIBED IN ITEMS (Z AND (3) ABOVE. THAT MEETS ALL OF THE FOLLOWING CONDITIONS: A) EXPOSED AREA OF AN INDIVIDUAL PANE GREATER THAN 9 SQ. FT. B) BOTTOM EDGE LESS THAN 18 INCHES ABOVE THE FLOOR. C) TOP EDGE GREATER THAN 36 INCHES ABOVE THE FLOOR. D) ONE OR MORE WALKING SURFACES WITHIN 36 INCHES HORIZONTALLY OF THE PLANE OF THE GLAZING. ENGINEERED ROOF TRUSSES NO INSULATION IN ATTIC 4X8 JAMES HARDI 8" VERTICAL GROOVE SHEETS APPLIED TO BOTTOM OF ROOF TRUSSES WITH 8D NAILS 8" OC (TYP) SINGLE COARSE KNOCK OUT LINTEL BLOCK COARSE AT TOP OF WALL WITH 145 HORIZONTAL REBAR TIED TO ALL VERTICAL RODS, POUR SOLID WITH 3000 PSI CONCRETE _8" PRECAST LINTEL OVER ALL OPENINGS IN WALL (TYP) STRUCK JOINT PAINTED BLOCK WALLS ON INTERIOR #5VERTICAL REBAR FROM FOOTINGS TO TOP OF WALL AT LOCATIONS SHOWN ON FLOOR AND FOUNDATION PLAN TIED TO ALL REBAR IN LINTEL. AND FOOTINGS. POUR CELL SOLID WITH 3000 PSI CONCRETE. ALL REBAR LAP TO BE MINIMUM 25" 4" 3000 PSI CONCRETE OVER CLEAN COMPACT TERMITE TREATED SOIL. COVER WITH 6 MILL VISQUEEN AND USE 6/6 10/10 WIRE MESH \ 16"X12" 3000 PSI CONCRETE FOOTING WITH WITH 2-0 REBAR ON CHAIRS WALL SECTION DETAIL S-1 NOT TO SCALE USE 1 SIMPSON HETA20 STRAP AT ONE SIDE OF ALL ROOF TRUSSES AT BLOCK 12' 0" 2'0" 24" CANTILEVER ROOF LINE WALL. FILL NAIL HOLES WITH 10DX 1/2" NAILS. r r �x ENGINEERED ROOF TRUSS PLAN 1/4" = 1101 1 1/2" CDX ROOF SHEATHING NAILED PER ROOF SHEATHING DETAIL WITH 8D RS NAILS. COVER WITH #30 FELT.INSTALL MASTER RIB 26 GA PAINTED STEEL ROOFING OR EQUAL AS PER MANUFACTURES SPECIFICATIONS SECURE ALL ROOF TRUSSES TO BLOCK WALLS USING SIMPSON HETA20 TRUSS STRAPS, FILL NAIL HOLES WITH 10DX 1 1/2' NAILS 0 60 TOP OF BLOCK WALL 8' 4" I 1, 4„ 2X4 WOOD SUB FASCIA WITH OVERHANG ALUMINUM FASCIA, DRIP AND VINYL SOFFIT NO INSULATION IN WALLS STRUCK JOINT PAINTED BLOCK WALLS ON EXTERIOR BUILDING FINISH FLOOF 0 BOTTOM OF FOOTING 2x4 CROSS -BRACING @ RIDGE 20'-0" MAX I7 Lq I a IN lm_ m Ims MR SEE TRUSS SYSTEM ENGINEERING DRAWINGS FOR ANY ADDITIONAL BRACING OR CROSS BRACING REQUIREMENTS REQ. MINIMUM TRUSS BRACING t ENGINEERED ROOF TRUSSES NO INSULATION IN ATTIC 4X8 JAMES HARDI 6" VERTICAL GROOVE SHEETS APPLIED TO BOTTOM OF ROOF TRUSSES WITH 8D NAILS 8" OC (TYP) SINGLE COARSE KNOCK OUT LINTEL BLOCK COARSE AT TOP OF WALL WITH 1 #5 HORIZONTAL REBAR TIED TO ALL VERTICAL RODS, POUR SOLID WITH 3000 PSI CONCRETE 8" PRECAST LINTEL OVER ALL OPENINGS IN WALL (TYP) \� STRUCK JOINT PAINTED BLOCK WALLS ON INTERIOR #5VERTICAL REBAR FROM FOOTINGS TO TOP OF WALL AT LOCATIONS SHOWN ON FLOOR AND FOUNDATION PLAN TIED TO ALL REBAR IN LINTEL. AND FOOTINGS. POUR CELL SOLID WITH 3000 PSI CONCRETE. ALL REBAR LAP TO BE MINIMUM 25" 4" 3000 PSI CONCRETE OVER CLEAN COMPACT TERMITE TREATED SOIL. COVER WITH 6 MILL VISQUEEN AND USE 6/6 10/10 WIRE MESH 16"X12" 3000 PSI CONCRETE FOOTING WITH WITH 245 REBAR ON CHAIRS 1' 0" 6" WALL SECTION DETAIL S-2 NOT TO SCALE #5 VERTICAL RODS FROM FOOTINGS BELOW TO TOP OF WALL. PLACED AT ALL CORNERS, EACH — SIDE OF ALL OPENINGS AND SPACED MAXIMUM 4'0"OC TOP/BOTTOM CHORD GABLE END BRACING @ 48" O.C. MAX FOR THE FIRST 4 ROWS OF TRUSSES ( MIN 2X4) W -1 m Q 0 CONT. BOTTOM CHORD BRACING (1"x4" MIN.) @ 1 U-0" MAX. O in W O W LL O w 5'-0" 12' 0" 5' 0" s- r - - - -■r ----- ------- - - li it li S iI M li it li II li �I li Ih i ■ O ■ I LI II II ■ I i 3' 4" 1,14, ih I I I I I ib I� �I I� �I■ iN I ll �I II r I I I 4" CONCRETE I SIDEWALK ■I I I I J L■ I I - — — — — — ■■ 1 - 11 •----------------------, b l II l l ifl � s- I I� II 1 1 II l — •— — —� — — — — -- — — — -' ■ - S- FOUNDATION PLAN 1/4" = 1' 0' NOTE: SEE SANITARY PLAN FOR PLUMBING FIXTURE LOCATIONS ROOFEDGE 3 O Q O ti�A O O Oc� O O O O _IRIDGE 0)2 1 U) O O� in ��Q L O O 2 2 O O 3 � O O O O O O ip O Z W LU J m Q O 0 ED C O GABLE END PARTIAL ROOF PLAN ZONE O 8dRING SHANK NAILS AT 6" O.C. AT EDGES 8dRING SHANK NAILS AT 12" O.C. INTERMEDIATE ZONES 2O O3 8dRING SHANK NAILS AT 6" O.C., 4" O.C. AT ROOF EDGES, RIDGE LINE, OR GABLE ENDWALL NOTE: END JOINTS FOR SHEATHING SHALL BE STAGGERED AND OCCUR OVER A FRAMING MEMBER. ROOF SHEATHING NAILING NOT TO SCALE ENGINEERED ROOF TRUSSES NO INSULATION IN ATTIC 4X8 JAMES HARDI 8" VERTICAL GROOVE SHEETS APPLIED TO BOTTOM OF ROOF TRUSSES WITH 8D NAILS 8" OC (TYP) SINGLE COARSE KNOCK OUT LINTEL BLOCK COARSE AT TOP OF WALL WITH 1-#5 HORIZONTAL REBAR TIED TO ALL VERTICAL RODS, POUR SOLID WITH 3000 PSI CONCRETE 8" PRECAST LINTEL OVER ALL OPENINGS IN WALL (TYP) STRUCK JOINT PAINTED BLOCK WALLS ON INTERIOR OF EACH SIDE #5VERTICAL REBAR FROM FOOTINGS TO TOP OF WALL AT LOCATIONS SHOWN ON FLOOR AND FOUNDATION PLAN TIED TO ALL REBAR IN LINTEL. AND FOOTINGS. POUR CELL SOLID WITH 3000 PSI CONCRETE. ALL REBAR LAP TO BE MINIMUM 25" 4" 3000 PSI CONCRETE OVER CLEAN COMPACT TERMITE TREATED SOIL. COVER WITH 6 MILL VISQUEEN AND USE 6/6 10110 WIRE MESH __\_L 16"X12" 3000 PSI CONCRETE FOOTING WITH WITH 245 REBAR ON CHAIRS WALL SECTION DETAIL S'3 NOT TO SCALE ARKAY ENGINEERING INC. STRUCTURAL ENGINEERS �c�`i 3 RfCHARD L. K.Ii D E Y ' FLORIDA LICENSE NUM3ER ?7296 I HERBY CERTIFY Ti AT E PLANS AND SPECIFICATIONS WERE PREPARED BY ME OR UNDER ".iY DIRECT SUPERVISION ARE IN COMPLIANCE WI'rH CHAPTER 16, SECTION 1609 OF THE FLORIDA BUILDING CODE 2010 AND ASCE 7-10 FOR 137 MPH WIND ZONE RISK CATEGORY ii Zu z 0" Ln � z 0.0 A Q Z U) W M N (D CV M r Z FW— 0 0 Z m 0 U LL 2 � O 3: 'I—^ ` BUJ 2 1.,1.. W � N Q O Z W Z Z rD V TOTAL AREA I 152 SQ. FT. S1 ARKAY # I`wb°Z� TII�1'iT: IT. I i I TAJ1 1..:m Id7-. CAI 11L..ldi•1 �7R11111 111,.. _l 11 N:..,L � ..1 LOW VOL FOR LAV FAUCET HEATER LOCATION ELECTRI(."P4AL PLAN 1 /411 = 1' 0' 100 AMP 24 CIR TYPICAL PANEL 1 WALL PACK LIGHT/ TIMER 1 P20 2 1 STORAGE LIGHTS 1 P20 3 RESTROOM LIGHTS & FAN 1 P20 4 INSTANT HOT WATER / LAV 1 P20 5 INSTANT HOT WATER / MOP SK 1 P20 6 GFI RECEPTACLE 1 P20 7 EMERGENCY LIGHTS 1P20 8 SPACE 9 SPACE 10 SPACE 11 SPACE 121 SPACE 13 SPACE 14 SPACE 15 SPACE 16 SPACE 17 SPACE 18 SPACE 19 SPACE 20 SPACE 21 SPACE 22 SPACE 23 SPACE 24 SPACE LOAD CALCULATIONS LOAD DEMAND FACTOR TOTALS LIGHTING 152 X 3 456 RECPTS 1 X 180 180 TANKLESS WATER HEATERS 1 @ 360 360 TOTAL 996 996 VA 208 VOLTS = 4.8 AMPS ELECTRICAL NOTES 1. All work to be done in accordance with all current national and local Codes and ordinances. 2. Notify Engineer of any discrepancies between these drawings and the actual field conditions. Obtain clarifications from the Engineer or Owners prior to commencing work. 3. Contractor will visit site prior to bidding, no allowances for any extra expenses will be granted as a result of not visiting site. 4. Wire to be THHN/THWN Copper, min. size 14 AWG, unless shown otherwise. 5. RACEWAYS: RIGID STEEL CONDUIT: full weight galvanized threaded pipe, EMT CONDUIT: compression fittings, PVC: schedule 40, all as allowed by local codes. Seperate raceways shall be used for each voltage system. 6. Any installation conflict with other trades shall be brought to the attention of the Engineer for clarification before proceeding. 7. Contractor will verify location of equipment and connect as required for clearances and connections. 8. All ourdoor electrical equipment to be NEMA 3R rated. LIGHTING & ELECTRICAL LEGEND A bon (� ED LITHONIA LB 10X48 2 LAMP 110V GROUND BOSCH GL 5 WRAP FLUORESCENT FIXTURE FAULT OUTLET ARISTON 2 1/2 GALLON TANKLESS WATER HEATER BI 120V 1500 WATTS LITHONIA MNSB 1 32 L T8 2 LAMP FLUORESCENT 100 OFM FIXTURE - NUTONE 766 HL - EXHAUSTFAN O PANEL $MS MOTION OCCUPANCY SENSOR SWITCH STANDARD SWITCH METER �yy--�� 0= EMERGENCY LIGHT LITHONIA TWAC WITH BATTERY B.U. MINI WALL PACK 3- #3 THNN 1-#3 N SINGLE PHASE BREAKER PANEL MAIN 1-#e G FOOTER STEEL - GROUND ROD CONCRETE ENCASED "UFER" ELECTRODE REQUIRED PER - CURRENT N.E.C. AND MUST BE INSPECTED PRIOR TO CONCRETE PLACEMENT ELECTRICAL RISER DIAGRAM NOT TO SCALE 54" MIN TOILET is" MIN PAPER HOLDER 42' MIN o ri m in HANDICAP TOILET DETAIL F11MIN MIN I,, I. LAY i f ' z CLEAR FLOOR ' SPACE -------------- 60" MIN GRAB BARS A GRAB BAR SHALL BE PROVIDE. LOCATED 33" INCHES FROM AND PARALLEL TO THE FINISHED FLOOR. MEASURED - VERTICALLY TO THE TOP OF THE RAIL WITH VARIATION OF NOT MORE THAN 1/2 INCH AND, I. SHALL HAVE AN OUTSIDE DIAMETER OF 1 1/2 INCHES 2. SHALL PROVIDE 1 1/2 INCHES OF CLEARANCE BETWEEN THE RAIL AND THE WALL. 3, SHALL BE 60 DESIGNED AND SUPPORTED AS TO WITHSTAND A LOAD OF NOT LESS THAN 290 LBO APPLIED AT ANY POINT. DOWNWARD OR HORIZONTALLY. 4, SHALL, BE CONTINUOUSLY GRASPABLE ALONG THE ENTIRE LENGTH. SPECIAL NOTE, GRAB BAR MEETING THE APPLICABLE ANSI STANDARDS ARE DEEMED TO BE IN COMPLIANCE WITH THE INTENT OF THE LAW WHETHER CENTER SUPPORTS EXIST OR NOT, S. SHALL. BE AT LEAST 42 INCHES LONG AND SHALL BE CENTERED AT THE LEADING EDGE OF THE WATER CLOSET, ------------------- 6" MAX, X TOE CLEARANCE- � L � ., Z g air q A 11' MAX LAV DEPTH O" MIN KNEE CLEARANCE HANDICAP SINK DETAIL- SINK 1. SINK SHALL BE MOUNTED WITH THE COUNTER OR RIM NO HIGHER THAN 34" FROM THE FINISH FLOOR, EACH SINK SHALL BE MINIMUM OF 6 1/2' DEEP, 2. CLEAR FLOOR SPACE RESTROOMS SHALL HAVE AN UNOBSTRUCTED SPACE OF AT LEAST 60" IN DIAMETER OR 5Y BY 12" FINISH INSIDE DIMENSIONS ADJACENT TO THE LAVATORY AREA, SUCH CLEAR FLOOR SPACE SHALL ADJOIN OR OVERLAP AN ACCESSIBLE ROUTE AND SHALL EMEND A MAXIMUM OF IS" UNDERNEATH THE LAVATORY OR SINK PLUMBING FIXTURE SCHEDULE SLOAN OPTIMA FAUCET ETF-600 LAVATORY KOHLER MODEL K-2030-0 WHITE CHROME FINISH SUPPLY AND DRAIN PIPING TO HAVE TAMPER PROOF SHIELD UNDER SINK BOSCH GLS ARISTON 2 1/2 TO BE INSTALLED IN STORAGE TANKLESS GALLON AREA BEHIND LAVATORY WATER HEATER WATER CLOSET KOHLER MODEL K-4368-0 SLOAN MANUAL FLOOR MOUNT ADA FLUSHOMETER 110 WALL MOUNT VERITEK CHROME FAUCET TO FIT MOP SINK SOLID MOLDED TUB TUB WITH WATER HOSE MANUFACTURE TO BE ADAPTER DETERMINED 1 ALL WATER AND SANITARY PIPING TO BE EXPOSED AND ACCESSIBLE FROM THIS SIDE OF MASONRY WALL SANITARY PLAN 1 /411= 1' 0' PIPE NOTE: SANITARY PIPING TO BE SCHL 40 PVC COLD AND HOT WATER LINES TO BE CPVC OR EQUAL ELECTRICAL SPECIFICATIONS 1.1 SCOPE D. CIRCUIT BREAKERS: Molded case, thermal -magnetic quick -make, quick -break, bolt -on type with A. WORK INCLUDED: Include the following Work in addition to items normally part of this Section: manually operated insulated trip -free handle. Multi -pole types with internal common trip bar. 01 Wiring for lighting and power. Terminals suitable for copper or aluminum conductors. Interrupting capacity minimum 10,000 RMS 02 Installation of lighting fixtures with lamps. symmetrical amperes circuit breakers to be Square "D" or equal, type as required. 03 Lighting panelboards and distribution panelboards. 04 Connection of equipment shown. E. PANELBOARDS: Voltage, phasing and ampere ratings as indicated, circuit breaker type as indicated, 05 Control wiring. busbars of hard drawn copper, minimum 98% conductivity, galvanized steel back box, door and trim. 06 Disconnection and removal of existing fixtures and wiring not to be reused. All corners lapped and welded, hardware chrome plated with flush lock and catch. Hinges semi- 1.2 MINIMUM COMPLIANCE STANDARDS concealed, 5 knuckle steel with nonferrous pins, 180 degree openings. Minimum gutter space 5- A. All work shall be done in accordance with the requirements of the following: 3/4" sides, top and bottom. Increase size where required by code. Directory holder complete with clear plastic transparent cover indicating typewritten list of feeder cables, conduit sizes, 01 Latest adopted issue of the National Electrical Code, NFPA 70. circuit numbers, outlets of equipment supplied, and their location. Circuit breaker type 02 Other applicable NFPA Codes. panelboards to be Square "D" type NQOD or I -Line, or equal. A plastic label shall be located on exterior of 03 Regulation of local authorities having jurisdiction. anelboard identifying the system voltage, phase, and current rating. B. Furnish and install all labor, material and equipment and services necessary for complete and p 9 y g ' p g' safe installation of the electrical system indicated on the drawings and noted in the F. WIRING DEVICES: All devices the product of the same manufacturer. Wall switches single pole, 20 specifications hereinafter. Electrical systems and equipment shall in general include the ampere, 120 volt. Wall switches three-way, 20 ampere, 120 volt. Receptacles duplex, 2 wire; 3 following: pole grounded, 20 ampere, 120 volt. 01 General provisions for electrical work. 02 Wiring, distribution equipment and devices. G. DEVICE PLATES: Provide for all outlets where devices are installed. Provide engraved marking for 03 Lighting fixtures and lamps. special outlets. Provide blank plates for empty or future outlet boxes. DEVICE AND DEVICE PLATES 04 Grounding system. COLORS TO BE VERIFIED WITH INTERIOR DESIGNER AND OWNER. 1.3 GENERAL PROVISIONS FOR ELECTRICAL WORK 1.5 LIGHTING FIXTURES AND LAMPS A. DRAWINGS: Electrical drawings considered diagrammatic and indicate general arrangement of work A. Furnish and install complete system of lighting fixtures, lamps, accessories and supports as and systems. Refer to other drawings to verify location of equipment, etc. Check drawings of specified and indicated. Submittals of equal quality are allowed. other trades to verify exact space condition or underground lines. Drawing Scales prohibit the 1.6 GROUNDING SYSTEM indication of all offsets, fittings and accessories required, however these items will be provided by this subcontractor at no extra cost to the owner. A. EQUIPMENT: Ground non -current carrying metal parts of panelboard, raceways and all lighting B. QUALITY OF MATERIALS: New, best of their respective kind, free from defects, and listed by fixtures. All conduits shall have equipment grounding conductors. Underwriter's Laboratories, Inc. or bearing their label. C. SHOP DRAWINGS: Submit four (4) copies of shop drawings for lighting fixtures and panelboards. 1.7 INSTALLATION Obtain approval before equipment is ordered, built or installed. A. Secure all supports to building structure. Support horizontal runs D. EXCAVATION AND BACKFILLING: Excavate, backfill and restore surfaces for all electrical work. of metallic conduit not more than 10 feet apart. Run exposed raceways parallel with or at right E. Visit site and inspect existing facilities before bid in order to ensure proper evaluation of angles to walls. working conditions and location of existing equipment. B. Pass raceways over water, steam or other piping when pull boxes are not required. No raceway within 3 inches of steam or hot water pipes, or appliances, except crossings where raceway shall 1.4 WIRING, DISTRIBUTION EQUIPMENT AND DEVICES be at least 2 inches from pipe cover. A. CONDUCTORS: Copper, in accordance with ASTM Standards, size references AWG. Conductors No. 10 and C. Cut conduit ends square, ream smooth. Paint male threads of field threaded conduit with graphite smaller size solid, No. 8 and larger stranded. Insulation of conductor thermoplastic, type THHN base pipe compound. Draw up tight with conduit couplings. (min. size: No. 12) any wire installed outside, underground, in slabs, or exposed to moisture D. Leave wire sufficiently long to permit making final connections. In raceways over 50 feet in shall have THWN insulation. which wiring is not installed, furnish pull wire. B. RACEWAYS: RIGID STEEL CONDUIT, full weight pipe galvanized, threaded, and minimum 1/2 inch except E. Verify locations of outlets and switches. ARKAY ENGINEERING INC. as noted or required for wiring. ELECTRICAL METALLIC TUBING (EMT), thin wall pipe, galvanized, threadless, F. Support panel, junction and pull boxes independently to building structure with no weight bearing STRUCTURAL ENGINEERS comression fittings, and minimum 1/2" except as noted or required for wiring. FLEXIBLE STEEL CONDUIT, on conduits. continuous singlestrip, galvanized, and minimum 1/2" size except as noted or required for wiring. PVC G. Connect conduit to motor conduit terminal boxes with flexible conduit; minimum 18 inches in f CONDUIT, heavy duty type, size as indicated. Type AC or MC cable where permitted. Separate raceways shall length and 50% slack. Do not terminate in or fasten raceways to motor foundation. be used for each voltage system. H. Contractor to remove and salvage all abandoned electrical equiment. I. This contractor shall warrant all labor and materials for one year from date of final written I t � C. DISCONNECT SWITCHES: General Duty, horsepower rated for motor loads 600 or 250 volt rating, fused acceptance. R;CHARD L. KIDOEY P.:_.. or non -fused as noted; number of poles as indicated, cover interlocked with switch. Enclosure p /FLORIDA LICENSE NUMBER 37296 T THF-.ND SPECIFICATIONS NEMA 1 for indoor use and NEMA 3R for weatherproof applications. Switch to be Square "D" or equal. WEE EBPRE AR'!1:i' ED B/ME ,S'UE',' DE.RLMA DIRECT SUPERVISION ARE IN COMPLIANCE WITH 0I f FTER 16, SECTION 1609 OF THE FLORIDA BUILDING CODE 2010 AND ASCE 7-10 FOR 137 MPH WIND ZONE RISK CATEGORY 11 cm 01 � d a o LL O N s � � W M Q 1 IL LL mF LD L u� W � V co r Iti A %0 McAN� 11 I!- L Z L U_ so � J m Z ul ip�ul 4 ) !Y (%Y�gt W S) Ld 8) 0 1-1814s CZ Hsu W Q Z 0 W W CY N }- 04 M Z p w ~ p o Z m O I— J U U. O U) W � Y W � N Q LL � O U � W Z Z D 0 TOTAL AREA 152 SQ. FT. E'� P 1 ARKAY # 1+143