HomeMy WebLinkAbout6900 Gall Blvd (4)IND8X OF DRAWINGS a IN - ZEPHYH 6900 GALL BLVD 'lux/Mull 1 0 E71 oo� of NO 4 DI ., \D\, , e' .. \\ 71 \ RA w �\ \ \ \ `\• xv Ada \ Q; O\ i, F."mummlim L PROPOSED WORK KEY NOTES NEW VINYL PLANK FLOORING 56"X9" THROUGHOUT UNLESS OTHERWISE NOTED. REFER TO FINISHES SCHEDULE ON ID-02 FOR ADDITIONAL INFORMATION ❑2 MINOR FLOOR PREPARATION AND LEVELING AS REQUIRED NEW 4" VINYL BASEBOARD THROUGHOUT UNLESS OTHERWISE NOTED. REFER TO FINISHES SCHEDULE ON ID-02 FOR ADDITIONAL INFORMATION ® NO CHANGE IN ELEVATION 0 REPAIR—PATCH/SAND/PAINT PARTITION IF REQUIRED AS A RESULT OF DEMOLITION. FINISH TO MATCH EXISTING © EXISTING FINISH FLOOR TO REMAIN IF IN GOOD CONDITION OTHERWISE REPLACE IT WITH NEW FLOORING TO MATCH THE REST F7 NEW DESK BY FURNITURE PROVIDER. FURNITURE FINAL SELECTION TO BE DETERMINED BY OWNER ® NEW FURNITURE MODULES (SEATING) BY OTHERS. FURNITURE FINAL SELECTION TO BE DETERMINED BY OWNER 09 EXISTING BASEBOARD TO REMAIN IF EXISTING FLOORING IS TO REMAIN OTHERWISE REPLACE IT WITH NEW BASEBOARD TO MATCH THE REST 10 EXISTING VIEWING WINDOW TO BE FRAMED IN AND FINISHED WITH 1/2" G.W.B. ON BOTH SIDES TO MATCH EXISTING WALL FINISH 11 INFILL OPENING WITH 1/2" G.W.B. ON METAL STUDS TO MATCH EXISTING WALL FINISH 12 NEW MILLWORK BUILT—IN CABINETS WITH COUNTERTOP FOR RECEPTION STORAGE BY OTHERS 13 LINES DENOTES LIMIT OF NEW FINISH FLOOR 14 PROVIDE ADA COMPLIANT THRESHOLD IF REQUIRED AT DISSIMILAR FINISH FLOOR TRANSITION. THRESHOLD SHALL BE 1/2" HIGH MAXIMUM. FAC 404.2.5/ FAC 302 AND 303 15 NEW MODULAR MILLWORK DESK/ COUNTER BY OTHERS. REFER TO ID PLANS FOR DETAILS. FINISH TO BE DETERMINED BY OWNER 16 PRINTER COMPARTMENT BELOW COUNTER 17 NEW G.W.B./METAL STUDS PARTITION. REFER TO WALL TYPES FOR DETAILS 18 CONTRACTOR TO PROVIDE BLOCKING AT BULKHEADS AND INTERIOR PARTITIONS FOR WALL MOUNT TVs AND CURTAINS 19 ADD (1) ADDITIONAL LAYER OF 1/2" GYPSUM BOARD TO EXISTING GYPSUM INTERIOR PARTITIONS THROUGHOUT ENTIRE MAMMO ROOM FOR SHIELDING. RADIATION PROTECTION SHALL BE DESIGNED AND APPROVED BY OWNER LICENSED PHYSICIST F261 PROVIDE STAINLESS STEEL TRANSITION STRIP AT DOORWAY AT CHANGE OF DIRECTION IN FLOOR. REFER TO ID DRAWINGS FOR FLOORING PATTERN 21 CLEAN, PREP AND PAINT ALL DOORS AND FRAMES THROUGHOUT PER INTERIOR FINISHES SCHEDULE ON ID-02. PAINT FINAL SELECTION TBD BY OWNER 22 NEW (18"X18") LOCKER BY FURNITURE COMPANY. COLOR AND FINISH TO BE DETERMINED BY OWNER 23 NEW ADA COMPLIANT LOCKER BY FURNITURE COMPANY. LOCKER SHALL COMPLY WITH FAC 803. COLOR AND FINISH TO BE DETERMINED BY OWNER 24 THE UNOBSTRUCTED HIGH SIDE REACH SHALL BE 48 INCHES MAXIMUM AND THE LOW SIDE REACH SHALL BE 15 INCHES MINIMUM A.F.F. 25 NEW BENCH BY FURNITURE COMPANY. COLOR AND FINISHES TO BE DETERMINED BY OWNER 26 NEW ADA COMPLIANT BENCH BY FURNITURE COMPANY. BENCH SHALL BE PROVIDED PER FAC 803.4. BENCH SHALL HAVE SEAT THAT ARE 42 INCHES LONG MINIMUM AND 20 INCHES DEEP MINIMUM AND 24 INCHES MAXIMUM PER FAC 903.3 27 TOP OF THE BENCH SEAT SURFACE SHALL BE 17 INCHES MINIMUM AND 19 INCHES MAXIMUM A.F.F. PER FAC 903.5 28 DOOR MOUNTED COAT HOOK AT 48" A.F.F. ON CENTER. CENTER HOOK HORIZONTALLY WITH DOOR WIDTH. TYP. AT ALL RESTROOMS AND CHANGE ROOMS 29 5'-0" (60") DIAMETER TURNING CIRCULAR SPACE FAC 304.3.1 30 30"X48" CLEAR FLOOR SPACE FORWARD APPROACH PER FAC 305 31 30"X48" CLEAR FLOOR SPACE PARALLEL APPROACH PER FAC 305 32 MANEUVERING CLEARANCE AT MANUAL SWINGING DOOR PER FAC 404.2.4.1 33 3'-0" HIGH MAXIMUM A.F.F. FAC 904.4.1 34 PREPARE SURFACES, PRIME AND PAINT ALL INTERIOR PARTITIONS AND HARD CEILINGS PER INTERIOR FINISHES DRAWING AND SCHEDULE ON ID-02 35 ACCENT PAINT COLOR SPECIFICATION AND LOCATION PER INTERIOR FINISHES DRAWING AND SCHEDULE ON ID-02 36 EXISTING G.W.B. LOW PARTITION TO BE FRAMED AND FINISHED WITH 1/2" G.W.B. UP TO EXISTING HEADER IN ORDER TO ENCLOSE ROOM AS INDICATED IN PLAN WITH HATCH 37 NEW WALL HUNG 1/4" CLEAR GLASS MIRROR WITH POLISHED EDGES IN ALL CHANGE ROOMS ABOVE BENCH. REFER TO FINISHES SCHEDULE ON ID-02 38 NEW TOILET PAPER DISPENSER AT ALL RESTROOMS AS PER AKUMIN STANDARDS. DISPENSER SHALL NOT BE OF A TYPE THAT CONTROLS DELIVER OR THAT DOES NOT ALLOWED CONTINUOUS PAPER FLOW FAC 604.9.6 39 TOILET PAPER DISPENSER SHALL BE 7" MINIMUM AND 9" MAXIMUM IN FRONT OF THE WATER CLOSET MEASURED TO THE CENTER LINE OF THE DISPENSER 40 THE OUTLET OF THE DISPENSER SHALL BE 15" MINIMUM AND 48" MAXIMUM ABOVE THE FINISH FLOOR AND SHALL NOT BE LOCATED BEHIND GRAB BARS 41 NEW WALL MOUNTED WASTE PAPER BASKET AT ALL RESTROOMS AS PER AKUMIN STANDARDS. TOP OF BASKET AT 48" MAXIMUM AND LOW SIDE 15" MINIMUM A.F.F. 42 NEW SOAP DISPENSER AT ALL RESTROOMS AS PER AKUMIN STANDARDS. DISPENSER TO BE MOUNTED 44 INCHES ON CENTER A.F.F. 43 NEW TOWEL PAPER DISPENSER AT ALL RESTROOMS AS PER AKUMIN STANDARDS. TOP OF DISPENSER AT 48 INCHES MAXIMUM A.F.F. 44 CONTRACTOR TO SUBMIT SHOP DRAWINGS TO INTERIOR DESIGNER FOR REVIEW AND APPROVAL PRIOR FABRICATION EXISTING TOP TRACT STRUCTURAL DECK EXISTING EXISTING TOP TRACT STRUCTURAL DI MARK LOCATION INTERIOR E!! SCHEDULE DOOR FRAME REMARKS ROOM NAME WIDTH HEIGHT THICK MATERIAL FINISH MATERIAL FINISH 1 HALL BY RECEPTION 3'-0" 6-8" 1 3/" HOLLOW METAL PAINTED METAL PAINTED 2 CLOSET (2) 2'-6" 6-8" 1 3/4" HOLLOW METAL PAINTED METAL PAINTED 3 WAITING AREA (2) 3'-0" T-0" 1 3/4" HOLLOW METAL PAINTED METAL PAINTED 4 STORAGE ROOM 3'-0" T-0" 1 3/4" HOLLOW METAL PAINTED METAL PAINTED 5 DEXA ROOM 3'-0" T_0" 1 3/4" HOLLOW METAL PAINTED METAL PAINTED 6 OFFICE 3'-0" T-0" 1 3/4" HOLLOW METAL PAINTED METAL PAINTED 7 ELECTRICAL ROOM 3`-0" 6'-8" 1 3/4" HOLLOW METAL PAINTED METAL PAINTED 8 CHANGE ROOM 1 3'-0" 6-8" 1 3/4" HOLLOW METAL PAINTED METAL PAINTED PRIVACY LATCH 9 CHANGE ROOM 2 3'-0" 6'-8" 1 3/4" HOLLOW METAL PAINTED METAL PAINTED PRIVACY LATCH 10 MAMMOGRAM ROOM 3`-O" 6-8" 1 3/4" HOLLOW METAL PAINTED METAL PAINTED SEE NOTES 3, 4, 5, 6, 7 1. FINISH PER FINISHES SCHEDULE ON ID DRAWING ID-02 2_ STYLE AND HARDWARE TO MATCH EXISTING 3_ DOOR SHIELDING: DOOR AND DOOR FRAME SHOULD BE EQUIVALENT TO 1 MILLIMETER OF STEEL 4_ DOOR AND DOOR FRAME SHALL HAVE EQUAL OR EQUIVALENT SHIELDING VALUE AS THAT REQUIRED IN THE WALL. IN WHICH IT IS INSTALLED 5_ DOOR AND DOOR FRAME SHIELDING VALUE SHALL BE DESIGNED AND APPROVED BY A LICENSED PHYSICIST 6_ DOOR LOCKSET HARDWARE SHIELDING SHALL BE DESIGNED AND APPROVED BY A LICENSED PHYSISCIST 7_ GAP BETWEEN THE BOTTOM OF DOOR AND THE FINISH FLOOR SHOULD BE KEPT AS SMALL AS POSSIBLE. THRESHOLD, IF REQUIRED, TO BE DETERMINED BY A LICENSED PH To the best of the Architect's knowledge these plans comply with the minimum standards of the applicable codes and life safety standards as determined in accordance with Chapter 553 and 663 of the Florida statutes For Construction ,Review Set Not for Construction ® Permit Set Bid Set F1 Record Set All designs, details and drawings indicated and represented are for use on and in conjunction with the specified project, the designs and drawings are the property of the Architect and shall not be reproduced in whole or in part without the written permission of M3o Architecture, Inc No. I Date Description Project Name PROPOSED FLOOR PLAN SCALE: 1 /4"=1'-0" AKUMIN - ZEPHYRHILLS INTERIOR ALTERATION 6900 GALL BLVD ZEPHYRHILLS, FL 33542 Project Team W11 GENERAL NOTES: CONTRACTOR SHALL MAINTAIN EXISTING FINISH FLOOR ELEVATION IN ORDER FOR NEW FINISH FLOOR TO BE FLUSH AT ALL TRANSITIONS AND DOORS ALL DIMENSIONS ARE GIVEN FROM FINISHED SURFACES UNLESS OTHERWISE NOTED CEILING HEIGHT IS INDICATED ON THESE PLANS AND MUST BE AS MAINTAINED AS STATED ALL NEW FINISH FLOOR SURFACES SHOULD BE LEVELED. THE FLOOR AREA UNDER THE EQUIPMENT BASES, EXTENDING 3'-0" IN ALL DIRECTIONS AROUND EACH BASE, MUST BE LEVEI ED, USING A CARPENTER'S LEVEL OF APPROPRIATE LENGTH, TO WITHIN 1/16" MAMMOGRAM ROOM SHIELDING SHALL BE DESIGNED AND APPROVED BY A LICENSED PHYSICIST OWNER/CONTRACTOR SHALL EMPLOY A REGISTERED PHYSICIST TO SPECIFY RADIATION PROTECTION 11401 SW 40th Street, Suite 301 Miami, FI 33165 t: (786) 275-4635 3 c: (305) 905-4657 ARCHITECTUREe. mtrejo@m3oarchitecture.com www.m3oarchitecture c o m AA26003093 AR97374 NOTES: WALKING SURFACES SHALL HAVE A SLIP —RESISTANT SURFACE AND BE SECURELY ATTACHED. FBC 1003.4 FLOOR AND GROUND SURFACES SHALL BE STABLE, FIRM, AND SLIP RESISTANT FBC ACCESSIBILITY 302.1 THRESHOLDS AT DOORWAYS SHALL NOT EXCEED 1/2 INCH (12.7 mm) ABOVE FINISHED FLOOR OR LANDING. RAISED THRESHOLDS AND FLOOR LEVEL CHANGES GREATER THAN 1 /4 INCH (6.4 mm) AT DOORWAYS SHALL BE BEVELED WITH A SLOPE NOT GREATER THAN ONE UNIT VERTICAL IN TWO UNITS HORIZONTAL (50—PERCENT SLOPE) FBC 1010.1.7/ FBC ACCESSIBILITY 303.3/404.2.5 THE RUNNING SLOPE OF WALKING SURFACES SHALL NOT BE STEEPER THAN 1:20. THE CROSS SLOPE OF WALKING SURFACES SHALL NOT BE STEEPER THAN ONE UNIT VERTICAL IN 48 UNITS HORIZONTAL (1:48) (2—PERCENT SLOPE) (FBC ACCESSIBILITY 403.3 INTERIOR FLOOR FINISH MATERIALS SHALL COMPLY WITH FBC SECTION 804.4.2 Sheet Title I Sheet No. PROPOSED FLOOR PLAN, SCHEDULE, A=3 GENERAL NOTES AND KEY NOTES DEMO KEY NOTES 1❑ EXISTING 2'X2' ACOUSTICAL CEILING TILE AND GRID TO BE REMOVED THROUGHOUT 0 EXISTING HEADER TO BE REMOVED 3] EXISTING HEADER TO REMAIN (TYP.) ® EXISTING LIGHT FIXTURE TO BE REPLACED WITH NEW ONE. REFER TO ELECTRICAL PLANS FOR ADDITIONAL INFORMATION �5 EXISTING EXIT SIGN TO BE REMOVED © ALL EXISTING CEILING MOUNTED SUPPLY AND RETURN AIR (S/A AND R/A) REGISTER TO BE REMOVED DURING CONSTRUCTION AND REINSTALLED AT SAME LOCATION ONCE NEW CEILING GRID WILL BE INSTALLED �7 EXISTING EMERGENCY LIGHT TO BE REMOVED. REFER TO ELECTRICAL PLANS FOR ADDITIONAL INFORMATION ® CLEAN AND PREPARE REMAINING SURFACE TO RECEIVE NEW WORK �9 EXISTING HARD CEILING TO REMAIN 10 EXISTING OPEN CEILING TO REMAIN DEMO REFLECTED CEILING PLAN SCALE: 1/4"=1'-0" • I To the best of the Architect's knowledge these plans comply with the minimum standards of the applicable codes and life safety standards as determined in accordance with Chapter 553 and 663 of the Florida statutes For Construction Review Set Not for Construction ® Permit Set Bid Set Record Set All designs, details and drawings indicated and represented are for use on and in conjunction with the specified project, the designs and drawings are the property of the Architect and shall not be reproduced in whole or in part without the written permission of M3o Architecture, Inc No. I Date Description Project Name AKUMIN - ZEPHYRHILLS INTERIOR ALTERATION 6900 GALL BLVD ZEPHYRHILLS, FL 33542 Project Team ITYP.I \ 11401 SW 40th Street, Suite 301 Miami, FI 33165 t: (786) 275-4635 3 c: (305) 905-4657 ARCHITECTUREe. mtrejo@m3oarchitecture.com www.m3oarchitecture. corn AA26003093 MILEYNIS E. TREJO AR97374 Sheet Title DEMO REFLECTED CEILING PLAN AND KEY NOTES Sheet No. MA PROPOSED RCP KEY NOTES 1❑ NEW 2'X2' T—BAR GRID AND TILE (TEGULAR EDGE) ATTACH TO STRUCTURAL DECK ABOVE. CEILING HEIGHT 8'-4" A.F.F. THROUGHOUT. REFER TO ID PLANS FOR SPECIFICATION`. �2 NEW 1/2" GYPSUM BOARD ON METAL STUDS HARD CEILING ATTACH TO STRUCTURAL DECK ABOVE. PROVIDE BLOCKING AS REQUIRED ❑3 NEW LED RECESS LIGHT FIXTURE. REFER TO ELECTRICAL PLANS FOR ADDITIONAL INFORMATION ® NEW EMERGENCY LIGHT FIXTURE. REFER TO ELECTRICAL PLANS FOR ADDITIONAL INFORMATION �5 NEW EXIT SIGN/COMBO. REFER TO ELECTRICAL PLANS FOR ADDITIONAL INFORMATION © REUSED ALL CEILING MOUNTED S/A AND R/A REGISTERS. AT SAME LOCATION. CONTRACTOR TO PROVIDE TEST AND BALANCE REPORT UPON COMPLETION OF THE JOB �7 EXISTING HEADER ® NEW HEADER 09 NEW 2'X2' NON—FERROUS T—BAR GRID AND TILE (TEGULAR L,GE) ATTACH TO STRUCTURAL DECK ABOVE. REFER TO ID PLANS FOR SPECIFICATIONS AND DETAILS I I % N-IF I 1W.0 %.W &.— &_01 I % &.— I &_ &.— %.w I &-- SCALE: 1 /4"=1'-0" To the best of the Architect's knowledge these plans comply with the minimum standards of the applicable codes and life safety standards as determined in accordance with Chapter 553 and 663 of the Florida statutes For Construction R Review Set Not for Construction ® Permit Set Bid Set ❑ Record Set All designs, details and drawings indicated and represented are for use on and in conjunction with the specified project, the designs and drawings are the property of the Architect and shall not be reproduced in whole or in part without the written permission of M3o Architecture, Inc No. I Date Description Project Name AKUMIN - ZEPHYRHILLS INTERIOR ALTERATION 6900 GALL BLVD ZEPHYRHILLS, FL 33542 Project Team 11401 SVV 40th Street, Suite 301 Miami, FI 33165 t: (786) 275-4635 3 c: (305) 905-4657 ARCHITECTURE e. mtrejo@m3oarchitecture.com www.m3oarchitecture.com AA26003093 Sheet Title PROPOSED REFLECTED CEILING AND KEY NOTES Sheet No. Am5 ELECTRICAL SYMBOL LEGEND GENERAL ELECTRICAL NOTES & SPECIFICATIONS 1. THE "GENERAL CONDITIONS OF THE CONTRACT", CURRENT EDITION, PUBLISHED IN STANDARD FORM BY THE AMERICAN INSTITUTE OF ARCHITECTS SHALL BE PART OF THIS CONTRACT. 2. IT IS NOT THE INTENT OF THESE PLANS AND SPECIFICATIONS TO SHOW EVERY AND ALL DETAILS OF CONSTRUCTION. THE CONTRACTOR SHALL FURNISH AND INSTALL ALL ITEMS REQUIRED FOR A COMPLETE ELECTRICAL INSTALLATION IN PROPER WORKING ORDER. 3. ALL WORK AND MATERIALS SHALL BE IN FULL ACCORDANCE WITH THE LATEST ADOPTED EDITION OF THE FLORIDA BUILDING CODE (2020) NEC 2017 AND THE LATEST STATE AND LOCAL CODES THAT APPLY. 4. THE CONTRACTOR SHALL TAKE OUT PERMITS, PROCURE CERTIFICATES AND PAY ALL FEES CONNECTED WITH HIS WORK. 5. BIDDERS SHALL VISIT THE SITE AND FAMILIARIZE THEMSELVES WITH ALL CONDITIONS SURROUNDING THE WORK. IT SHALL BE THE RESPONSIBILITY OF THE BIDDERS TO VISIT THE SITE OF WORK AND ACQUAINT THEMSELVES WITH ALL AVAILABLE INFORMATION REGARDING THE EXISTING FACILITIES. FAILURE OF THE BIDDERS TO SO INFORM THEMSELVES OF EXISTING CONDITIONS AND TO INCLUDE IN THEIR PROPOSALS A SUM SUFFICIENT TO COVER SAME WILL NOT ENTITLE THEM TO AN EXTRA. 6. THE CONTRACTOR IS REFERRED TO THE ARCHITECTURAL PLANS AND SPECIFICATIONS. SUCH PLANS AND SPECIFICATIONS ARE CONTRACT DOCUMENTS. 7. DRAWINGS ARE DIAGRAMMATIC AND INTENDED TO SHOW APPROXIMATE LOCATIONS OF ALL ELECTRICAL ITEMS. EXACT CONDUIT ROUTING SHALL BE DETERMINED IN THE FIELD, UNLESS OTHERWISE NOTED (LION). 8. CONTRACTOR SHALL SUBMIT REQUESTS FOR SUBSTITUTION IN WRITING TO THE ENGINEER, 10 WORKING DAYS PRIOR TO BIDDING DATE. 9. THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS FOR APPROVAL FOR ALL EQUIPMENT AND MATERIALS. SUBMIT A MINIMUM OF FOUR SETS TO THE A/E. 10. THIS CONTRACTOR SHALL TOUCH UP OR REFINISH THE FACTORY FINISH OF EQUIPMENT MARRED DURING DURING SHIPMENT OR INSTALLATION. THE CONTRACTOR SHALL BE RESPONSIBLE TO REPAIR TO ORIGINAL CONDITIONS ANY AND ALL DAMAGES TO BUILDING SURFACES, EQUIPMENT, AND FURNISHING CAUSED DURING THE PERFORMANCE OF WORK. 11. THE ELECTRICAL INSTALLATION SHALL MEET THE APPROVAL OF THE ENGINEER BEFORE ACCEPTANCE BY THE OWNER. 12. THE CONTRACTOR SHALL BE A STATE LICENSED CONTRACTOR. 13. THE ENTIRE INSTALLATION SHALL BE PERFORMED UNDER DIRECT SUPERVISION OF A LICENSED MASTER ELECTRICIAN IN A FIRST CLASS WORKMANLIKE MANNER. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE ALL LABOR, MATERIALS AND SUPERVISION NECESSARY TO ACCOMPLISH THE WORK AS SHOWN AND/OR NOTED ON THE DRAWINGS. 14. ELECTRICAL WORK SHALL NOT INTERFERE WITH CLEARANCES REQUIRED FOR GENERAL AND MECHANICAL CONSTRUCTION. SHOULD ELECTRICAL WORK BE INSTALLED WHICH INTERFERES WITH THE WORK OF OTHER TRADES, SUCH WORK SHALL BE CORRECTED AT NO COST TO THE OWNER. THE CONTRACTOR SHALL SUBMIT (4 COPIES) EQUIPMENT LAYOUT OF ALL ELECTRICAL SPACES, ROOMS, ETC., TO ARCHITECT FOR APPROVAL PRIOR TO ORDERING EQUIPMENT OR INSTALLING CONDUITS, ETC., LAYOUTS SHALL CONSIST OF PLAN VIEWS (SCALED AT 1/2" = V-0") AND ELEVATIONS (DIMENSIONED) FOR EACH SPACE, ROOM, ETC., .AND SHALL INCLUDED EQUIPMENT FURNISHED BY OTHER TRADES. 15. GROUNDING SHALL COMPLY WITH THE NATIONAL ELECTRICAL CODE (ARTICLE 250) AND REQUIREMENTS OF THE INSPECTING AUTHORITY. ALL CONNECTIONS TO GROUND RODS SHALL BE MADE WITH UL APPROVED ACCESSIBLE GROUND CLAMPS, UNLESS OTHERWISE NOTED. 16. UPON COMPLETION OF WORK, THIS CONTRACTOR SHALL REMOVE ALL RUBBISH CAUSED BY HIS WORK AND SHALL THOROUGHLY CLEAN ALL ELECTRICAL EQUIPMENT. 17. ALL WORK SHALL BE GUARANTEED FREE FROM DEFECTS FOR A PERIOD OF ONE YEAR FROM DATE OF FINAL ACCEPTANCE. 18. ALL ITEMS OF ELECTRICAL EQUIPMENT ASSOCIATED WITH THE CONTROL OF ELECTRICAL CIRCUITS AND APPARATUS SHALL BE IDENTIFIED.. 19. ALL POWER AND LIGHTING CIRCUIT WIRING SHALL BE COLOR CODED AS FOLLOWS: 120 208V. 277 480V. PHASE "A" - BLACK PHASE "A" - BROWN PHASE "B" - RED PHASE "B" - ORANGE PHASE "C" - BLUE PHASE "C" - YELLOW NEUTRAL - WHITE NEUTRAL - GRAY GROUND - GREEN GROUND - GREEN 20. ALL CONDUCTORS SHALL BE COPPER, 60OV. #12 AND SMALLER, SOLID TYPE THWN/THHN; #10 AND LARGER, STRANDED TYPE THWN/THHN. 21. ALL CONDUCTORS FOR POWER LIMITED CABLES SHALL COMPLY WITH ARTICLES 725 & 760 OF N.E.C. LATEST EDITION. 22. NOMINAL MOUNTING HEIGHT OF DEVICES IN EXPOSED CONCRETE BLOCK, TILE OR BRICK WALLS SHALL ALL OCCUR WITHIN A STRUCTURAL COURSE. A MIN. AMOUNT OF BLOCK, TILE OR BRICK WALLS SHALL BE CU'i. 23. ALL ELECTRICAL EQUIPMENT AND DEVICES SHALL BE INDUSTRIAL GRADE, HEAVY-DUTY, AND U.L. LISTED UNLESS SPECIFIED OTHERWISE. ALL ELECTRICAL EQUIPMENT, DEVICES, WIRE, ETC., SHALL BE LISTED, FOR THE INTENDED USE, WITH UNDERWRITER'S LABORATORIES INC. (UL), WHERE STANDARDS HAVE BEEN ESTABLISHED BY UL. AS A MINIMUM, ALL EQUIPMENT SHALL MEET APPLICABLE STANDARDS, FOR THE TYPE OF EQUIPMENT AND THE INTENDED USE, OF THE FOLLOWING. A. AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI) B. ILLUMINATING ENGINEERS SOCIETY (IES) C. AMERICAN SOCIETY FOR TESTING AND MATERIALS (ASTM) D. NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION (NEMA) NOTE: THESE STANDARDS ARE SUBORDINATE TO STANDARDS SET BY U.L. AND LOCAL CODES. 24. WIRING DEVICES SHALL BE SPECIFICATION GRADE. MINIMUM SIZE OF OUTLET BOXES SHALL BE 4" SQ. TRADE. OUTLET BOXES SHALL BE PRESSED STEEL IN DRY LOCATIONS, CAST ALLOY WITH THREADED HUBS IN WET OR DAMP LOCATIONS AND SPECIAL ENCLOSURE FOR OTHER CLASSIFIED AREAS. 25. ALL ELECTRICAL CONDUCTORS MUST BE IN CONDUIT. ALL CONDUITS SHALL BE INTERMEDIATE (IMC) OR RIGID GALVANIZED STEEL (RGS) EXCEPT THAT: (A) POLY VINYL CHLORIDE (PVC) CONDUITS MAY BE USED IN CONCRETE SLABS AND UNDERGROUND PROVIDED THAT ELBOWS AND RISERS ARE RGS; (B) ELECTRICAL METALLIC TUBING (EMT) MAY BE USED IN WALLS OR CEILINGS OF FINISHED AREAS WHERE NOT SUBJECT TO MECHANICAL DAMAGE, OR CORROSIVE CONDITIONS; (C) LIQUID TIGHT FLEXIBLE CONDUIT WHERE REQUIRED IN WET OR DAMP LOCATIONS; (D) FLEXIBLE METALLIC CONDUIT WHERE REQUIRED IN DRY LOCATIONS. FLEXIBLE CONDUITS SHALL BE USED FOR ALL VIBRATING EQUIPMENT SUCH AS MOTORS, ETC.ALL CONDUITS IN HAZARDOUS LOCATIONS SHALL MEET THE REQUIREMENTSOF NEC CHAPTER 5. THE USE OF ENT CONDUIT IS PROHIBITED. 26. APPLY 2 COATS OF BITUMASTIC COATING TO ALL METALLIC CONDUITS INSTALLED UNDERGROUND. 27. NO CONDUITS TO BE RUN IN DUCT WORK. A POLYESTER PULL CORD SHALL BE INSTALLED IN ALL EMPTY CONDUITS. 28. SIZE ALL WIREWAYS ACCORDING TO N.E.C. ARTICLE 376 AND 378 29. ALL RATED WALL/FLOOR PENETRATIONS ARE TO BE SEALED WITH A FIRE RATED SEALER, PER ASTM E814. 30. WHERE CORE DRILLING OF FLOORS/WALLS IS REQUIRED, CONTRACTOR SHALL SEAL OPENINGS AFTER UTILITIES HAVE BEEN INSTALLED. LOCATION OF CORED HOLES SHALL COORDINATE WITH LOCATION OF EQUIPMENT IN A MANNER TO BE CLEAN AND FUNCTIONAL. THE CONTRACTOR SHALL INSTALL ONLY ONE CONDUIT PER HOLE AND SEAL AROUND THE OPENING AS SPECIFIED ABOVE. 31, ANY VARIATION FROM THE PLANS ARE TO BE PREVIOUSLY APPROVED BY THE ENGINEER IN WRITING. 32. CONDUIT AND ELECTRICAL EQUIPMENT EXPOSED TO WEATHER MUST BE WEATHERPROOF (NEMA 3R). 33. FUSES SHALL BE BUSSMAN "FUSETRON" DUAL -ELEMENT FUSES FOR BRANCH CIRCUIT PROTECTION AND ALSO FOR MOTOR RUNNING PROTECTION IF REQUIRED, OR FUSES AS CALLED FOR ON DRAWINGS. 34. TERMINATIONS ARE TO BE MADE AS PER U.L. ARTICLE 486B. 35. THE GENERAL CONTRACTOR SHALL COORDINATE ALL ELECTRICAL SITE WORK. 36. ALL CIRCUIT BREAKERS SHALL BE INVERSE TIME TYPE (THERMAL MAGNETIC). MULTI -POLE CIRCUIT BREAKERS SHALL BE COMMON TRIP. NO TIE HANDLES PERMITTED. 37. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR FOR THE ADVANCED ORDERING OF LONG LEAD ITEMS, AS NOT TO INTERFERE WITH THE PRODUCTION OF OTHER TRADES RESULTING IN ANY DOWN OR LAG TIME. 38. THE CONTRACTOR SHALL VERIFY CIRCUIT DEVICE PROTECTIVE RATING FOR EQUIPMENT PRIOR TO CONSTRUCTION. 39. USE 3/4" EXTERIOR GRADE PLYWOOD BACKBOARDS FOR SURFACE MOUNTING GROUPED EQUIPMENT, PAINTED ON BOTH SIDES AND EDGES WITH TWO COATS OF NAVAL GRAY PAINT (FIRE RESISTANT). 40. NO CUTTING OR DRILLING OF STRUCTURAL ITEMS SHALL BE DONE WITHOUT PRIOR WRITTEN APPROVAL FROM A LICENSED STRUCURAL ENGINEER. 41 ALL DEDICATED OUTLETS SERVING EQUIPMENT SUCH AS REFRIGERATORS, WATER COOLERS, COPIERS, FAXES, ETC. SHALL HAVE SEPARATE NEUTRAL CONDUCTORS TO EACH DEVICE OR APPLIANCE. 42 ELECTRICAL POWER AND CONTROL WIRING FOR H.V.A.C. AND MECHANICAL EQUIPMENT SHALL BE FURNISHED AND INSTALLED BY THE ELECTRICAL CONTRACTOR. 43 ELECTRICAL CONTRACTOR SHALL VERIFY THE CEILING FINISHES AND SUSPENSION SYSTEMS FOR SELECTION OF THE PROPER TRIM AND SUPPORT ARRANGEMENTS OF THE FIXTURE. 44 ALL ELECTRICAL EQUIPMENT SHALL BE APPROVED AS SAFE FOR USE IN THE U.S. WORKPLACE, AS PER A "NRTL" RECOGNIZED ORGANIZATION (U.L., C.S.A., ETC.). 45 PROVIDE EXPANSION JOINTS WHERE REQUIRED AS PER N.E.C. 300-7(b). I To the best of the Architect's'<nowledge these plans comply with the minimum standards of the applicable codes and life safety standards as determined in accordance with Chapter 553 and 663 of the Florida statutes For Construction Review Set Not for Construction ® Permit Set Bid Set Record Set LIGHTING FIXTURE (SEE LIGHTING FIXTURE SCHEDULE ALSO) ® Oa CEILING LIGHT FIXTURE -UPPER CASE LETTER DESIGNATES FIXTURE TYPE, LOWER CASE LETTER DESIGNATES SWITCHING. -, EXIT SIGN (LIGHT FIXTURE) CEILING OR WALL MOUNTED DOUBLE SIDED SIGN- CONNECTED TO LIGHTING CIRCUIT. ARROWS INDICATE DIRECTIONS. PROVIDE WITH BATTERY PACK. TYPES CEILING OR WALL MOUNTED EXIT SIGN FIXTURE. CONNECTED TO LIGHTING CIRCUIT. AS SPECIFIED IN FIXTURE SCHEDULE. PROVIDE WITH BATTERY PACK. pCEILING TYPES OR WALL MOUNTED EMERGENCY/EXIT SIGN COMBO FIXTURE. CONNECTED TO LIGHTING CIRCUIT. AS SPECIFIED IN FIXTURE SCHEDULE. PROVIDE WITH BATTERY PACK. DUAL HEAD EMERGENCY STAND-BY LIGHT, WITH BATTERY PACK, WALL MOUNTED. MT. UP 7-6" A.F.F. TO � OF OUTLET BOX. �--� EXISTING HID EXTERIOR LIGHTING FIXTURE - POLE MOUNTED RECESSED MOUNTED 2X4 LED FIXTURE. E RECESSED MOUNTED 2X2 LED FIXTURE. &;J RECESSED MOUNTED 2X4 LED FIXTURE. HATCH DENOTES BATTERY BACK UP RECESSED MOUNTED 2X2 LED FIXTURE. HATCH DENOTES BATTERY BACK UP CEILING MOUNTED OCCUPANCY SENSOR. MODEL VAC-DT SERIES OR EQUIVALENT. WIRE AS PER MANUFACTURER SPECS TOGGLE SWITCHES (SPECIFICATION GRADE - IVORY COLOR) $a SINGLE POLE TOGGLE SWITCH, 20 AMP, 120/277V.,SPECIFICATION GRADE. LETTER DENOTES LIGHTS ON SWITCH "A'. MOUNT AT 48' A.F.F. TO CL OF OUTLET BOX UNLESS NOTED. 2 110 TWO POLE TOGGLE SWITCH , 20 AMP, 120/277V., SPECIFICATION GRADE LETTER DENOTES LIGHTS ON SWITCH "A'. MOUNT AT 48' A.F.F. TO CL OF OUTLET BOX UNLESS NOTED, 3 THREE 1'0 WAY SWITCH , 20 AMP, 120/277V., SPECIFICATION GRADE LETTER DENOTES LIGHTS SWITCHED. MOUNT AT 48" A.F.F. TO CL OUTLET BOX UNLESS NOTED. 4 1'0 FOUR WAY SWITCH , 20 AMP, 120/277V., SPECIFICATION GRADE LETTER DENOTES LIGHTS SWITCHED. MOUNT AT 48" TO CL OF OUTLET BOX A.F.F. UNLESS NOTED. 6 = OCCUPANCY/VACANCY SENSOR SWITCH VNW-D OR EQUIVALENT. 1,- LED COMPATIBLE DIMMER SWITCH. MT. AS DIRECTED ON PLAN. RECEPTACLES (SPECIFICATION GRADE - IVORY COLOR) po DUPLEX RECEPTACLE; 20 A.,120 V.,GROUNDING TYPE. MOUNTED 18" A.F.F. TO CL OF OUTLET BOX. (EXCEPT AS NOTED). HUBBELL 52621 U.O.N. GO DUPLEX RECEPTACLE; 20 A.,120 V.,GROUNDING TYPE. VERIFY MOUNTING HEIGHT. HUBBELL 52621 U.O.N. k� DUPLEX RECEPTACLE; 20 A.,120 V.,GROUNDING TYPE. SWITCHED AS PER PLAN. C30 QUADUPLEX RECEPTACLE 20 A., 120 V., GROUNDING TYPE. MOUNTED 18" A.F.F.. HUBBELL 4151 U.O.N. D DEDICATED HOSPITAL GRADE DUPLEX RECEPTACLE; 20 A.,120 V.,GROUNDING TYPE. MAY BE INSTALLED IN COVER OF WIREMOLD. DUPLEX RECEPTACLE MOUNTED HORIZONTALLY; 20 A.,120 V.,GROUNDING TYPE. MOUNTED AS NOTED ON PLANS (EXCEPT AS NOTED). DUPLEX GFI RECEPTACLE MOUNTED HORIZONTALLY; 20 A.,120 V.,GROUNDING TYP�. MOUNTED UP AS NOTED ON PLANS. EXCEPT IN RESTROOMS NEXT TO SINKS WHERE IT SHALL BE MOUNTED AT 42' A.F.F. TO C OF OUTLET. DUPLEX RECEPTACLE; 20 A.,120 V.,GROUNDING TYPE. MOUNTED 18" A.F.F. TO C OF OUTLET BOX. (EXCEPT AS NOTED). CONNECTED THRU EMERGENCY PANEL. 14 CEILING MOUNTED OUTLET BOX FLUSH WITH TILE. F-0 D DRYER RECEPTACLE. MT. UP 42" TO � OF OUTLET BOX. LJ LJ DENOTES FLOOR MOUNTED TELEPHONE SYSTEM DATA OUTLET 4-11/16" X 4-11/16" 2-1/8" WITH BUSHED HOLE COVER PLATE- MOUNTED 18" A.F.F. TO � OF OUTLET(EXCEPT AS NOTED) PROVIDED 3/4" E.C. FROM EACH OUTLET TO STUB UP 6" ABOVE CL'G SPACE (EXCEPT AS NOTED.) >1 DEDICATE PHONE LINE MOUNTED 18" A.F.F.LTO C OF OUTLET(EXCEPT AS NOTED) PROVIDED 3/4" E.C. FROM EACH OUTLET TO STUB UP 6" ABOVE CL'G SPACE (EXCEPT AS NOTED.) CONDUITS 1� ARROW DESIGNATES "HOMERUN" TO PANEL,HASH MARKS DESIGNATE NUMBER OF WIRES. INDICATES GREEN BOND WIRE ------ INDICATES CONDUIT RUN EXPOSED. NSS TRANSIENT VOLTAGE SURGE SUPPRESOR POWER DISTRIBUTION Vii I� VARIBLE FREQ. DRIVE WITH LINE SIDE BRAKER FURNISHED BY DIV. 15 MT'D AND CONNECTED BY DIV. 16 EP SAFETY SWITCH - HEAVY DUTY NEMA CLASS "A" IN NEMA 1 ENCLOSURE, OUTDOOR TYPE NEMA 3R. 20 3 Q DESIGNATES SWITCH RATING, "3" DESIGNATES POLES; "20" TIME DELAY FUSE; "30"SWITCH AMPS. HVAC MOTORIZED DAMPER FURNISHED BY DIV. 15 CONNECTED BY DIV. 16 CONTRACTOR. 4 MOTOR. (FURNISHED BY ARCH. DIV. 13, OR 15 CONNECTED BY DIV 16. OR ELEV./ESC. INSTALLER) ® 120/208V., 30, 4W. PANEL BOARD. REMOTE EMERGENCY OFF SHUNT TRIP SWITCH. JUNCTION BOXES EQUIPMENT JUNCTION BOX, FURNISHED WITH EQUIPMENT. a/O WALL CEILING MOUNTED JUNCTION BOX. MINIMUM 4" X 4" X 1 1/2" WITH BLANK PLATE. MT. WALL BOX UP AS SHOWN ON PLAN. dVos WALL/CEILING MOUNTED J.BOX FOR SIGNAGE. MT. WALL BOX UP AS SHOWN ON RAN. AUXILIARY SYSTEMS INTERCOM CALL BUTTON AND VOLUME CONTROL SWITCH C S COMBINATION CLOCK SPEAKER ED SINGLE GANG JUNCTION BOX FOR P.A. HORN SPEAKER. CONTRACTOR TO FIELD COORDINATE MOUNTING HEIGHT. ABBREVIATIONS ABBREVIATION DESCRIPTION ABBREVIATION DESCRIPTION A.C.T. ABOVE COUNTER TOP K.V.A. KILOVOLT AMPERES A.F.F. ABOVE FINISHED FLOOR MAX. MAXIMUM (TYP.) TYPICAL MIN. MINIMUM PNL. PANEL (MFR) MANUF. MANUFACTURER L.T. LIGHT GFI. GROUND FAULT INTERRUPTER FIXT. FIXTURE GND. GROUND BRKR. BREAKER W.P. WEATHER PROOF 0 PHASE M.C.B. MAIN CIRCUIT BREAKER PVC POLYVINYL -CHLORIDE F/N FULL NEUTRAL RGS RIGID GALVANIZED STEEL SURF. SURFACE PWR. POWER HTD. MOUNTED MTG. MOUNTING REC. RECEPTACLE oss if 1, 2 or 3 Hour Fire Rated �a Through Penetration Firestop for Single Metal Pipe through Concrete floors or walls using SYsIt TREMstop WBM. CAJ1144 F-RATING = 1, 2 and 3 Hr. T-RATING = 1, 2 AND 3 Hr. F=T 2 3A 36 1 .d. 2 a. a 3B 3A DRAWING NOT TO SCALE 10 FLOOR OR WALL ASSEMBLY = 4" TO 6" THICK CONCRETE. Q STEEL PIPE: 6" DIAMETER (OR SMALLER) SCHEDULE 40 (OR HEAVIER) STEEL. Q Max. Pipe Min. Forming Min. Fill F T Diameter Mat[. Thkns Mat]. Thkns Rating Rating (inches) (inches) (inches) (Hour) (Hour) 6 4 0.5 1 0 4 3.5 1 2 0.5 6 1.25 2.375 3 0 * ANNULAR SPACE IS 3/4" A. 4.0 pcf MINIMUM DENSITY MINERAL WOOL INSULATION, FRICTION FITTED. B. MINIMUM FILL THICKNESS OF TREMstop WBM. NOTE: FOR WALLS APPLY TREMstop WBM TO BOTH SURFACES OF WALL. DETA L-A CONCRETE WALL OR SLAB PENETRAT ON DUAL- 1 or 2 Hour Fire Rated Through oss if/. Penetration Firestop for Single G `Do Metal Pipe through Gypsum walls using TREMstop WBM. SYS t � VA/L1051 F-RATING = 1 and 2 Hr. T-RATING = 1 and 2 Hr. F=T 31. 3 - Ito 2 =_ 2 [DRAWING NOT TO SCALE 0 1 OR 2 HOUR FIRE RATED GYPSUM WALLBOARD/STUD WALL ASSEMBLY. 0 STEEL PIPE: 6" DIAMETER (OR SMALLER) SCHEDULE 40 (OR HEAVIER) STEEL. CONDUIT:4" DIAMETER (OR SMALLER) EMT OR RIGID STEEL CONDUIT. CIRCULAR DUCT: 4" DIAMETER (OR SMALLER) 26 GAUAGE (OR HEAVIER) GALVANIZED STEEL VENT DUCT. 0 TREMstop WBM: FILL MAXIMUM 3/4" ANNULUS WITH A THICKNESS OF 1 1/4" (2 HOUR F-RATING) OR 3/4" (1 HOUR F-RATING). DETAIL-B. GYPSUM WALL PENETRATION DETA L All designs, details and drawings indicated and represented are for use on and in conjunction with the specified project, the designs and drawings are the property of the Architect and shall not be reproduced in whole or in part without the written permission of M3o Architecture, Inc GENERAL DEMOLITION NOTES O CONTRACTOR SHALL DISCONNECT AND REMOVE ALL EXISTING ELECTRICAL WORK ASSOCIATED WITH STRUCTURES BEING DEMOLISHED AND/OR IN CONFLICT WITH NEW CONSTRUCTION. O2 ELECTRICAL WORK IN WALLS AND CEILINGS BEING DEMOLISHED, OR IN CONFLICT WITH NEW CONSTRUCTION, SHALL BE REMOVED, WIRING SHALL BE REMOVED BACK TO PANEL OR PRECEDING OUTLET. O3 ALL EXISTING ELECTRICAL WORK IN AREAS NOT AFFECTED BY THIS DEMOLITION SHALL REMAIN ENERGIZED FROM EXISTING CIRCUITS. O4 REFER TO ARCHITECTURAL DEMOLITION DRAWINGS FOR EXACT LOCATION OF AREAS TO BE REMOVED AND AREAS TO REMAIN. O EXISTING FIRE ALARM SYSTEM AND DEVICES TO REMAIN. TEST ALL DEVICES FOR PROPER OPERATION. REPLACE ANY DEFECTIVE COMPONENTS AS REQUIRED. COORDINATE ALL WORK WITH THE BUILDING FIRE ALARM MAINTENANCE CONTRACTOR. © CONTRACTOR TO IDENTIFY ALL CONDUITS .AND WIRES NOT IN USE IN CEILING SPACE AND REMOVE THEM ALL CONDUITS AND WIRES IN USE SHALL BE SECURED TO COMPLY WITH FLORIDA BUILDING CODE. O CONTRACTOR SHALL TURN OVER TO OWNER, OR DISPOSE OF, ALL EXISTING ELECTRICAL EQUIPMENT, AS INSTRUCTED IN WRITING BY OWNER. PRIOR TO COMMENCEMENT OF DEMOLITION, THE CONTRACTOR SHALL CONDUCT A WALK THRU WITH THE OWNER'S REPRESENTATIVE AND PREPARE A LIST OF ALL ITEMS TO BE DEMOLISHED AND RETURNED TO OWNER. THE LIST SHALL BE SIGNED BY BOTH PARTIES. ALL EXISTING EQUIPMENT TO BE TURNED OVER TO OWNER, SHALL BE DISCONNECTED, REMOVED AND CLEANED AND STORED IN A CLEAN, DRY AND SAFE ENVIRONMENT UNTIL IT IS TURNED OVER TO OWNER. ® EXISTING LIGHTING BRANCH CIRCUITS SHALL BE REUSED FOR NEW LIGHTING CIRCUITS. NO ELECTRICAL WORK TO BE DONE IN HATCHED AREAS UNLESS OTHERWISE SPECIFIED. DEMOLITION ELECTRICAL POWER PLAN SCALE: 3/16"=1'-0" CODED DEMOLITION NOTES 01 EXISTING POWER RECEPTACLE TO BE REMOVED ALONG WITH ASSOCIATED WIRES AND CONDUITS BACK TO PANEL OR PRECEDING OUTLET. REUSE CIRCUIT TO FEED NEW RECEPTACLES AS SHOWN ON E-3. ❑2 EXISTING POWER RECEPTACLE TO REMAIN AS SHOWN ON E-3. ❑3 EXISTING DATA OUTLET TO BE REMOVED ALONG WITH ASSOCIATED CAT5 WIRES AND CONDUITS. ® EXISTING ELECTRICAL PANEL TO REMAIN. ❑5 ALL EXISTING LIGHT SWITCH TO BE REMOVED ALONG WITH ASSOCIATED WIRES AND CONDUITS. © EXISTING LIGHT FIXTURE TO BE REMOVED ALONG WITH ASSOCIATED WIRES AND CONDUITS BACK TO PRECEDING JUNCTION BOX. TYPICAL FOR ALL. REUSE CIRCUIT TO FEED NEW LIGHTS. REFER TO DRAWING E-4 FOR NEW LIGHTING LAYOUT. ❑7 EXISTING EMERGENCY LIGHT TO BE REMOVED ALONG WITH ASSOCIATED WIRES AND CONDUITS. TYPICAL FOR ALL. ® EXISTING EXIT SIGN TO BE REMOVED ALONG WITH ASSOCIATED WIRES AND CONDUITS. TYPICAL FOR ALL. ❑9 EXISTING STAND ALONE RESIDENTIAL TYPE SMOKE DETECTOR TO BE REMOVED. 10 EXISTING X RAY IN USE WARNING SIGN TO REMAIN. 11 EXISTING RACK MOUNTED IT SWITCHES TO REMAIN. To the best of the Architect's knowledge these plans comply with the minimum standards of the applicable codes and life safety standards as determined in accordance with Chapter 553 and 663 of the Florida statutes For Construction ❑ Not for Construction ❑ Bid Set Review Set No ® Permit Set Record Set All designs, details and drawings indicated and represented are for use on and in conjunction with the specified project, the designs and drawings are the property of the Architect and shall not be reproduced in whole or in part without the written permission of M3o Architec`•jre, Inc Date Description Project Name AKUMIN - ZEPHYRHILLS INTERIOR ALTERATION 6900 GALL BLVD ZEPHYRHILLS, FL 33542 Project Team DEMOLITION ELECTRICAL LIGHTING PLAN SCALE: 3/16"=1'-0" M.E. Engineering Consultants, Inc. 11401 S.W. 40th Street, Suite 301 Ph:(305)905-4652 CA 29121 11401 SW 40th Street, Suite 301 Miami, FI 33165 t: (786) 275-4635 3 c: (305) 905-4657 MCHff WMN e. mtrejo@m3oarchitecture.com w w w m 3 c a r c h i t e c t u r e c o m AA26003093 5 0vvv �� �•.,.... � eve . X C, N S . S .4 STA Y0 Do Y ASS/©NAL_ Zoila Morales, Electrical P.E.#64981 Alexei Hidalgo, Mechanical P.E.#70807 Sheet Title ELECTRICAL DEMOLITION PLAN AND KEY NOTES Sheet No. Em2 1 "J" HOOKS SUPPORTED FROM STRUCTURE OR WALL. PROVIDE EVERY 6'-0" O.C. I I I TELECOM I.T. SWITCH STUB UP 6" ABOVE CEILING, AND 6" AWAY FROM WALLS. PROVIDE INSULATED BUSHING AND PULLWIRE. r------------- — -- CEILING LINE CEILING LINE EXISTING TELEPHONE BACKBOARD -':' —COMMUNICATION CABLING BUNDLED NEATLY ABOVE f CEILING & RUN PARALLEL TO 3/4" EMPTY CONDUIT WALL AND CEILING. SUPPORTED BY "J" HOOKS. i PROVIDE # 6 GREEN GROUND BONDING JUMPER FROM TELEPHONE EQUIPMENT TO COOPER GROUND BUS BAR IN ELECTRICAL ROOM. WALL MOUNTED DATA GROUNDING SYSTEM BUS OUTLET. BAR IN ELECTRICAL ROOM. .. • .. 18"AFF TYPICAL TELEPHONE/DATA SYSTEM TYPICAL RISER DIAGRAM N . T. S. 3/4" CONDUIT TO WIREWAY BEHIND MAMMOGRAM FINISH CEILING LINE -WL- 1 ` 2—#12 & 1-12 GND (WL) WARNING LIGHT USE TO WARNING LIGHT APPROVED FI INCANDESCEN CONTRACTOR TO PROVIDE 120 V POWER TO LIGHT & RUN A SWITCH LEG TO EQUIPMENT VIA WIREWAYS LOCATED INSIDE ROOM. --FINISH FLOOR LINE TYPICAL DOOR SWITCHM/ARNING LIGHT DETAIL N.T.S. CONTRACTOR TO TEST EXISTING GROUNDING SYSTEM LOCATED INSIDE THE MAIN ELECTRICAL ROOM AND MAKE SURE THAT IT IS IN GOOD MECHANICAL CONDITIONS. X-RAY WARNING LIGHTS ARE EXISTING TO REMAIN. CONTRACTOR TO TEST FOR PROPER OPERATION AND REPLACE IF NEEDED. RESTROOMS EXHAUST FANS ARE EXISTING TO REMAIN. CONTRACTOR TO CHECK FOR PROPER OPERATION AND REPLACE IF NEEDED. NO ELECTRICAL WORK TO BE DONE IN HATCHED AREAS UNLESS OTHERWISE SPECIFIED. LETTER SYMBOLS E — EXISTING TO REMAIN ER — EXISTING TO BE REMOVED DURING CONSTRUCTION AND REINSTALLED AFTER NEW WALL WILL BE IN PLACED. ALL DEVICES ARE NEW UNLESS OTHERWISE INDICATED BY SYMBOLS ABOVE. * — ALL EXISTING RECEPTACLES IN BATHROOMS, OUTDOOR OR WITHIN 6" OF SINKS SHALL BE REPLACED WITH NEW G.F.C.I. DECORA OR EQUAL. GR( " ' To the best of the Architect's knowledge these plans comply with the minimum standards of the applicable codes and life safety standards as determined in accordance with Chapter 553 and 663 of the Florida statutes ❑ For Construction ❑ Not for Construction ❑ Bid Set ❑ Review Set No ® Permit Set ❑ Record Set All designs, details and drawings indicated and represented are for use on and in conjunction with the specified project, the designs and drawings are the property of the Architect and shall not be reproduced in whole or in part without the written permission of Mao Architecture, Inc Date Description Project Name AKU M I N - ZEPHYRH I LLS INTERIOR ALTERATION 6900 GALL BLVD ZEPHYRHILLS, FL 33542 ELECTRICAL POWER PLAN SCALE: 1 /4"=1 '-0" Project Team M.E. Engineering Consultants, Inc. 11401 S.W. 40th Street, Suite 301 Ph:(305)905-4652 CA 29121 11401 SW 40th Street, Suite 301 Miami, FI 33165 t: (786) 275-4635 3 c: (305) 905-4657 MICH11EMM e. mtrejo@m3oarchitecture.com w w w m 3 o a r c h i t e c t u r e con AA26003093 iiiiidI0 �'�•.•.\c E10 NS•' F�®° • o.6 8 0.1 STAT O �• • Ie • �bz ka.•.\�44 �ONA� Zoila Morales, Electrical P.E.#64981 Alexei Hidalgo, Mechanical P.E.#70807 Sheet Title ELECTRICAL POWER PLAN RISER AND KEY NOTES Sheet No. E-3 D • AT THE END OF INSTALLATION CONTRACTOR SHALL MAKE SURE THAT MINIMUM 0.1 FOOT CANDLE AND AVERAGE OF 1 FOOT CANDLE ON EGRESS ILLUMINATION WAS ACHIEVED WHICH IS THE DESIGN INTEND AS PER FBC 1008.3.5. • SPECIFIED LIGHTING SYSTEM CONTROL COMPLIES WITH FBC E-505. COMMERCIAL LIGHTING TO COMFY WITH FBC CE 405 (ENERGY CODE). (2017 FBC) LIGHTING WAS DESIGNED SO EACH SPACE COMPLIES WITH POWER DENSITY R-QUIREMENTS SPECIFIED IN FLORIDA BUILDING CODE 2017-ENERGY CONSERVATION. IF REPLACED CONTRACTOR SHALL ASSURE COMPLIANCE. OCCUPANCY SENSORS SHALL COMPLY WITH 7.8.1.2.2 (1-7). LIGHTING FIXTURE SCHEDULE NOTES: 1. ALL LIGHT FIXTURES SPECIFIED, COULD BE SUBSTITUTED WITH LIGHT -FIXTURES OF EQUAL QUALITY PREVOIUSLY APPROVED BY OWNER/ENGINEER OF RECORD. 2. MOUNTING HEIGHT FOR EXIT -SIGNS SHALL BE AS FOLLOWS: WALL -MOUNTED IN OFFICE 6" ABOVE THE DOOR. PENDANT MOUNTED IN CORRIDOR (OFFICE) 7'-6" A.F.F. 3. CONTRACTOR SHALL ORDER ALL LIGHT -FIXTURES WITH THE REQUIRED HARDWARE FOR A COMPLETE INSTALLATION. THIS INCLUDES WIRING WHIP, FUSES, ETC. 4. EMERGENCY BATTERY LIGHT SHALL BE CONNECTED TO THE SAME BRANCH CIRCUIT FEEDING THE NORMAL LIGHTS IN THE AREA AND AHEAD OF ANY LOCAL SWITCH. 5. ALL FIXTURES PROVIDED WITH BATTERY PACKS SHALL BE ABLE TO PROVIDE A MINIMUM OF 80% OF TOTAL FIXTURE LUMEN OUTPUT FOR 1.5 HOURS MINIMUM 6. LIGHT FIXTURES TYPE C TO BE RETROFITTED WITH NEW HALO CAN WITH LED KIT AND TRIM. KEEP THEM FED FROM EXISTING CIRCUIT. TYPICAL. ALL EXIT AND SHALL BE CON SWITCH TO LIG LIGHTING FIXTURE SCHEDULE TYPE DESCRIPTION R MFATALOG C NUMBER VOLTS LAMPS INPUT WA17S MOUNTING REMARKS A RECESSED 2' X4' LED METALUX 24GRLED504ORT MVOLT LED 45 RECESSED 3500 K B RECESSED 2'X2' LED METALUX 22GRLD244OR1 MVOLT LEE} 19 RECESSED 3500 K C 6" DQV�iNL1GHT HALO I-1271CAT HOUSING WITH3500 LT 560WH6935 MVOLT LED 8.7 RECESSED K NON FERREOUS TRIM X Exit Sign Sure -Liter APX7R 120 LED 0.99 Ceiling/Wall include Direction arrowsas per plan E Emergency Light Sure -Liter JAP2SQLED 120 LED 1.8 Ceiling /t///alI XE Exit/Emergency Combo Sure -Liter APCRSQ 120 ILED 3.7 Ceiling/Mall A' A: (A] { A' ( A: ( A; ( A', ( A', A' (A] B: ( 13: { A: ( A; ( A: W 5 SIEMENS VOLTS: 200A08V 3t�, 4 TYPE: TO EXISTING Panel A BUS: MOUNTING FLUSH EXISTING FED MA75 KVATRANSFORMER V1t1TH 4- TYPE MANS: M:C.B, LOCATION: CORRIDOR 3/0 CU VMRES Pic, 10K CKT # DESCRIPTION POLE C.B. TRIP (AMPS) WIRE CON- D1JIT VA ..A.. VA LOAD ..B.. VA LOAD „C,. VA LOAD VA CON- C}U1T WIRE C.B. TRIP (AMPS) POLE DESCRIPTIC 1 EASTIN'G 1 20 E E 720 1,440 720 E E 20 1 EXISTING 3 EXISTING 1 20 E E 1 720 1 1,440 7201 E E 20 1 ENSTING 5 EXISTING 1 20 c E 720 1,440 720 E E 20 1 EXISTING 7 EXISTING 2 30 E E 1,500 2,220 720 E E 20 1 EXISTING 9 1,500 2,220 720 E E 20 1 EXISTING 11 EXISTING 1 20 E E 720 1,440 720 E E 20 1 EXISTING 13 EXISTING 1 20 E E 7201 1A40 720 E E 20 1 EXISTING 15 EXISTING 1 20 E E 720 1,440 720 E E 20 1 EXISTING 17 EXISTING 1 20 E E 720 1,440 720 E E 20 1 EXISTING 19 EXISTING 1 20 E E 720 1,440 720 E E 20 1 EXISTING 21 EXISTING 1 20 E E 720 1,440 720 E E 20 1 EXISTING 23 EXISTING 1 20 E I E 7201 1,440 720 E E 20 1 EXISTING 25 RECEPTACLES 1 20 #12 1/2" 540 1,125 585 1/2" #12 20 1 RECEPTACLES 27 PRINTER 1 20 #13 1/2" 1,200 1,7401 540 1/2" 1 #12 20 1 RECEPTACLES 29 EXISTING 1 20 E E 720 1,260 540 E E 20 1 EXISTING 31 EXISTING 1 20 E E 720 1,440 720 E E 20 1 EXISTING 33 EXISTING 1 20 E E 7201 1,440 720 E E 20 1 EXISTING 35 EXISTING 2 3 E E 2,548 3,268 720 E E 20 1 EXISTING 37 2,548 12,6281 10,080 39 EXISTING 2 60 E E 3,600 13,680 10,0801 E E 100 1 3 PANEL B 41 3,600 13,680 10,030 TOTALS 21,733 23,400 23,968 CONNECTED LOAD (KVA): 69.1 DEMAND LOAD (KVA): 69.1 AMPS/PHASE: 192 (A)- Existing circuit to remain feeding same load (By Existing breaker new wires and conduit to feed new load_ E_ Existing wire and conduit to remain To the best of the Architect's knowledge these plans comply with the minimum standards of the applicable codes and life safety standards as determined in accordance with Chapter 553 and 663 of the Florida statutes ❑ For Construction Review Set Not for Construction ® Permit Set Bid Set ❑ Record Set All designs, details and drawings indicated and represented are for use on and in conjunction with the specified project, the designs and drawings are the property of the Architect and shall not be reproduced in whole or in part without the written permission of M3o Architecture, Inc . No. I Date Description Project Name ELECTRICAL LIGHTING PLAN SCALE: 1 /4"=1'-0" AKUMIN - ZEPHYRHILLS INTERIOR ALTERATION 6900 GALL BLVD ZEPHYRHILLS, FL 33542 Project Team M.E. Engineering Consultants, inc. 11401 S.W. 40th Street, Suite 301 Ph:(305)905-4652 CA 29121 11401 SW 40th Street, Suite 301 Miami, FI 33165 t: (786) 275-4635 3 c: (305) 905-4657 MCHnawme. mtrejo@m3oarchitecture.com www,m30architecture c o m AA26003093 Zoila Morales, Electrical P.E.#64981 Alexei Hidalgo, Mechanical P.E.#70807 Sheet Title I Sheet No. ELECTRICAL LIGHTING PLAN, E=4 PANEL SCHEDULE AND NOTES - - ..i II �.. �..... 111 I „ ,J 1. a i:: SMew iliffia 1�.-dill 7111� Lilai:�i ld, i r,d�t:n�'.ru lA...:alJ ;:�I.:I �I I I i I i I I i , ;, I .., T-17 — A I . - �� -� .. -; : � .. - r. ,�.,: .:r• -rr, � :,.�:r� ��; mxi r ., r, n,� r =:-..mirm r-�m .: ..: r •.I...�•. �,, .. ., �: -- ... :. • I ,,:, .... �� .. �.:: � .�. Rt`I.. $'"1. 'w�' .. ... I!l�'. �I`�- � CFI 4^FA�Ar:1FAeAlI111F:R�CAF r�F *p 9 .: rF'�^""'17r^ : - r: ae�l?7! .:. .. - .. �, r .. Cfrs'I . - IF ��;m-. I w ,. �?.n-r—�-r. •: