HomeMy WebLinkAbout2801 E SR 60 (2)FIRE ALARM SYSTEM DEVICE LEGEND SYMBOL DESRIPTION COMMENT PRODUCT I.D. MOUNTING HEIGHT ELEC. BOX FIRE ALARM CONTROL VIGILANT SERIES VS1-RD 72" AFF TO TOP FRCP PANEL WITH DACT OF CONTAINER MFR. FIRE ALARM REMOTE VIGILANT SERIES RLCD-R 60" AFF TO TOP FAAP ANNUCIATOR PANEL OF CONTAINER MFR. FIRE ALARM REMOTE VIGILANT SERIES MIRBPS6A BESIDE FACP FEP POWER SUPPLY MFR. F❑ ADDRESSABLE MANUAL VIGILANT SERIES 42" TO 48" AFF PULL STATION GSA-M278 DOUBLE ACTION NOTE 2 C ADDRESSABLE VIGILANT SERIES CEILING 0 SMOKE DETECTOR V-PD WITH K1-SB BASE MOUNT B �2 ADDRESSABLE SUPP./ VIGILANT SERIES GSA -SD DUCT S/R RTN. SIDE DUCT DET. WITH SD-T60 SAMPLING TUBES MOUNTED D DUCT DETECTOR VIGILANT SERIES GSA -SD CEILING ® REMOTE TEST SWITCH WITH SD-TRM MOUNT C ADDRESSABLE VIGILANT SERIES PROVIDE DRY M MONITOR MODULE GSA-CT1 ENCLOSURES E ADDRESSABLE DUAL VIGILANT SERIES PROVIDE DRY ® 2 MONITOR MODULE GSA-CT2 ENCLOSURES E ADDRESSABLE VIGILANT SERIES PROVIDE DRY C R RELAY MODULE GSA-CR ENCLOSURES E a F SPRINKLER FURNISHED BY OTHERS FIELD LOCATE �--c FLOW SWITCH MONITORED BY NEW FACP PER FLOOR PLANS D T SPRINKLER .FURNISHED BY OTHERS FIELD LOCATE TAMPER SWITCH MONITORED BY NEW FRCP PER FLOOR PLANS D WALL MOUNT WHEELOCK EXCEDER LHS3 SERIES 82" AFF TO HORN STROBE (*) CANDELA RATING BOTTOM OF LENS C CEILING MOUNT WHEELOCK EXCEDER LHSC3 SERIES CEILING HORN STROBE (*) CANDELA RATING MOUNT C CLG. WALL MOUNT W.P. WHEELOCK ASWP-2475W-FR SERIES 82" AFF TO o, Wp HORN STROBE 115 CANDELA RATING BOTTOM OF LENS WBB WALL MOUNT W.P. WHEELOCK ASWP-2475C-FR SERIES 82" AFF TO WP CLG. HORN STROBE 115 CANDELA RATING BOTTOM OF LENS WBB CEILING MOUNT WHEELOCK EXCEDER LSTC3 SERIES CEILING C CLG. STROBE (*) CANDELA RATING MOUNT FIRE ALARM 120VAC DITEK DTK-120HW SERIES FIELD LOCATED 120 CIRCUIT PROTECTOR AT FACP/BPS D MFR. DENOTES BACKBOX FURNISHED BY MANUFACTURER AFF DENOTES ABOVE FINISHED FLOOR WBB DENOTES WEATHERPROOF BACKBOX BACKBOXES REQUIRED BY OTHERS 2-1 /8' 2-1 /8" 1-1 /2" DEEP DEEP DEEP 4" SQ. 1-1 /2" BLANK SINGLE 4-1 1 /16" 4-1 1 /16" OCTAGON EXT. RING PLATE GANG BOX SQ. BOX EXT. RING BOX BACKBOX SCHEDULE A - 4" BOX WITH SINGLE GANG RING B - 4" BOX WITH ROUND RING OR OCTAGON BOX C - 4" BOX 2-1 /8" DEEP WITH SGPR D - 4" BOX ADJACENT FLEX TO DEVICE E - 4" BOX 2 1/8" DEEP WITH EXTENSION BOX GENERAL NOTES SYSTEM INSTALLATION IN ACCORDANCE WITH 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE FLORIDA SPECIFIC ADDITION OF NFPA 1, THE FIRE CODE (2015) NATIONAL ELECTRIC CODE (2014 EDITION) NFPA 72 (2013 EDITION) NATIONAL FIRE ALARM SIGNALING CODE - FLORIDA SPECIFIC EDITION OF NFPA 101 NFPA 101 (2015 EDITION) FLORIDA ADMINISTRATIVE CODE 61G15-32 ALL OTHER CODES MANDATED BY THE LOCAL AUTHORITY HAVING JURISDICTION 1) FIRE ALARM SYSTEM WIRING:. STYLE B (CLASS B) INITIATION DEVICE CKTS. STYLE Y (CLASS B) NOTIFICATION APPLIANCE CKTS. STYLE 4 (CLASS B) ADDRESSABLE SIGNALING LINE 2) LOCKBOX TO BE MOUNTED OUTSIDE OF THE BUILDING WITHIN 6' OF PRIMARY ENTRANCE DOOR AND AT A HEIGHT NOT TO EXCEED 12' AFF NOR BE LESS THAN 8' AFF TO BOTTOM OF BOX. KEYBOX SHALL BE ZONED INDEPENDENTLY IF REQUIRED BY THE LOCAL AUTHORITY FIRE ALARM SYSTEM BATTERY CALCULATION VIGILANT SERIES VS1 -RD (FACP) ITEM QTY DESCRIPTION STANDBY ALARM STANDBY ALARM per unit per unit Total Total A 1 MASTER CONTROLLER 0.155 0.204 0.155 0.204 B 1 REMOTE ANNUCIATOR 0.036 0.146 0.036 0.146 C 18 ADDRESSABLE DEVICES 0.0005 0.0005 0.009 0.009 D 1 FULL LOAD NOTIFICATION 0.000 3.750 0.000 3.750 E 3 AUX. 24VDC RELAY 0.000 0.015 0.000 0.045 TOTAL DRAW AMPS 0.200 4.154 STANDBY FOR 24 HOURS AMPS 4.800 ALARM FOR 5 MINUTES AMPS .347 TOTAL BATTERY IN AMPS REQUIRED 5.147 X 1.2 FACTOR 6.177 BATTERIES SUPPLIED 7.0 AMP HOUR NOTIFICATION CIRCUITS FUSED AT 2.5 AMPS VIGILANT SERIES MIRBPS6A (PCPs) ITEM QTY DESCRIPTION STANDBY ALARM STANDBY ALARM per unit per unit Total Total A 1 MASTER CONTROLLER 0.175 0.270 0.175 0.270 B NOTIFICATION CIRCUIT 1 0.000 1.022 0.000 1.022 C 1 NOTIFICATION CIRCUIT 2 0.000 1.109 0.000 1.109 p 1 NOTIFICATION CIRCUIT 3 0.000 1.511 0.000 1.511 E 1 NOTIFICATION CIRCUIT 4 (SPARE) 0.000 0.000 0.000 0.000 TOTAL DRAW AMPS 0.175 3.912 STANDBY FOR 24 HOURS AMPS 4.200 ALARM FOR 5 MINUTES AMPS .326 TOTAL BATTERY IN AMPS REQUIRED 4.526 X 1.2 FACTOR 5.432 BATTERIES SUPPLIED 7.0 AMP HOUR NOTIFICATION CIRCUITS FUSED AT 3.0 AMPS FIRE ALARM FUNCTIONAL MATRIX:Ld Uj cn Of U CONTROL UNIT ANNUNCIATION NOTIFICATION SUPPLEMENTARY o r Z � Z J m N Z CD O � ~ CD a- a-cn a. � � ¢ WO �Q N � cwn cn N N CD~ O In� Z W J 7 ZO W J �] � ' Q m ta_ i J CD J Z � Z � Z � Z Q � H N W O W O Q Q (/w? C=? N N N W lJi W I.Ji wQ c-3 � c.) � c.> � U o N � LU of � Uj W= Uj Ld rr c=n Q Q Q Q Q Q Q Z � cwi MANUAL PULL STATION X X X X P.E. STAMP 0) CIO co 00 CD L CD FT 00 O LO LCJ "I, co� C3 � I 00 � CO � cr) O s` O w r-I I w a W Q � c) CYJ co O I �4 � W � o LO \ Q H O C 2 w � CO � �D W � O � q O U1 � W � � O � q � L� � O N � C4 E- O E- O DRAWN BY: DQDD APPROVED BY: DATE: 11 /21 /19 scA-E: AS INDICATED PROJECT N0: DEVICE LEGEND BATTERY CALCS. RISER DIAGRAM SEAL DATE FA 1 O LO LCJ "I, co� C3 � I 00 � CO � cr) O s` O w r-I I w a W Q � c) CYJ co O I �4 � W � o LO \ Q H O C 2 w � CO � �D W � O � q O U1 � W � � O � q � L� � O N � C4 E- O E- O DRAWN BY: DQDD APPROVED BY: DATE: 11 /21 /19 scA-E: AS INDICATED PROJECT N0: DEVICE LEGEND BATTERY CALCS. RISER DIAGRAM SEAL DATE FA 1 Q H O C 2 w � CO � �D W � O � q O U1 � W � � O � q � L� � O N � C4 E- O E- O DRAWN BY: DQDD APPROVED BY: DATE: 11 /21 /19 scA-E: AS INDICATED PROJECT N0: DEVICE LEGEND BATTERY CALCS. RISER DIAGRAM SEAL DATE FA 1 DRAWN BY: DQDD APPROVED BY: DATE: 11 /21 /19 scA-E: AS INDICATED PROJECT N0: DEVICE LEGEND BATTERY CALCS. RISER DIAGRAM SEAL DATE FA 1 El WALK IN WALK IN GAS METER COOLER COOLER WALK IN UNIT UNIT FREEZER a o0 0000000000",D 0 WALK IN COOLER w W ° = m n- D °an J F o 00000m� WP � ; S1-2 mo n D o Cn 1 15cd A Cl) CLG. ° WQ B mm 11�0Wo O00> gQr� WALK IN F EZER (D W o oEo� �wzw cna¢> S1-3 1 15cd WP CLG. NOTIFICATION SPACING BASED ON MAXIMUM SMOOTH CEILING HEIGHT OF 20'-0" AREA IS PROTECTED BY AN AUTOMATIC FIRE PROTECTION SPRINKLER SYSTEM MONITORED BY THE HOUSE FACP RINNAI MODEL CU160E NATURAL GAS ON DEMAND WATER HEATER UNIT#1 UNIT#2 10'0" A.F.F. VERIFY HEIGHT 0 d O Z � D o 0 w 00 m 5 F1 of me Am z000 0 c is G) C o=_ N r m m G o O ;­(D o of mO0 D D A Be OW ro -Ai O Q A a O m � Z ° . m4 > CO 7,O WALK IN COOLER o0 S1-4 1 15cd CLG. WP 0 X �w of x wIr a o� m UO ¢ � O _ Wm co IC-0 GAS p F DRPY-0120 = Z J � FRYER O ¢ ' w GA rr m a DRPY-0120 m Z Paz FRYER 0a¢ 0 U) cz7 W DRPY-0120 m w FRYER GAS DRPY-0120 Cl) w FRYER _ 0 >_w z J J ¢ of Z C0 - YOU ~ o� U) z w w m U) _ w w o >> rn � az70< o0 ® a ° CORNELIUS NORDIC UNDER COUNTER > z o CUBE ICE MACHINE 309LB PER DAY * 0 �n 30" WIDE 30" DEEP 39" TALL .° 36" X21"ICE BIN BY OTHERS n D n D n D n D n D n O O a° Q° 4 Q O11O GFl 00HAND S.S. PREP WASH ABLE 60"X30" SINK COFFEE MACHINE WITH COLD WATER LINE AND DRAIN CONNECTION S1-5 75cd CLG. o m wWw N ��O 1O�Qd ma U) 71 71 z0 A Sm m ,T1 =m O x S.S. PREP TABLE 72"X30" 0 a-x wF, Xm aw (� J C/) m H S1 —6 EOLR 75cd 48"X30" SPRAY CLG. WASH SINK WITH GRINDER 36- WIDE HAND WASH 36" DEEP SINK DISHWASHER 60 AMP BRK 3P O ETE1 UP STORAGE 6" ABOVE PASS ~THRU COUNTER 6" ABOVE PASS -THRU COUNTER S2-6 75cd CLG. 96"X36" TABLE BALCONY LINE ABOVE B TO S1-1 BPS 75cd CLG. MEETING AREA F] 1.7 lid ►MOIA1:1 S2-1 75cd CLG. S2-2 75cd CLG. TO BPS POWER COMPANY TRANS ELECTRICAL 1 2 C f MECHANICAL D ROOM ON GFI a D S2-3 75cd CLG.Uvi a B S2-4 1.6 F 75cd -- - CLG. 311106'' 0 0 STORAGE D 1.8 \� j � S2-5 � � � � i / '1*2 ELEVATOR 1W1P cd TO �� D FAC P F S2-7 P 1.13 A D 1.12 75cd MEETING FAA P D AREA + + EOLR F T M 2 EOLR 1.14 A P,S TO FAC P C R 1.9 PRIMARY ELEVATOR RECALL D,P C R 1.10 ALTERNATE ELEVATOR RECALL D,P C R 1.11 FIRE HAT WARNING LIGHTS n LEVEL ONE FIRE ALARM SYSTEM PLAN 1 /411 = 1' Oil SCALE: 1 /411 SOUND OVERRIDE RELAY BPS FACP n ' TO -H" FAC P 11 FIRE ALARM SYSTEM CABLE LEGEND MARK DESCRIPTION PURPOSE A GENESIS SERIES 4506 2 COND. 18AWG FPLP INITIATION CIRCUIT B GENESIS SERIES 4513 2 COND. 14AWG FPLP NOTIFICATION CIRCUIT D GENESIS SERIES 4506 2 COND. 18AWG FPLP ADDRESSABLE SIGNALING LLINE CIRCUIT P GENESIS SERIES 4513 2 COND. 14AWG FPLP 24VDC POWER CIRCUIT R GENESIS SERIES 4506 (2) 2 COND. 18AWG FPLP DUCT DETECTOR REMOTE TEST SWITCH S GENESIS SERIES 4506 2 COND. 18AWG FPLP SERIAL LINE CKT. TO ANNUCIATOR FPLP DENOTES FIRE POWER LIMITED PLENUM CABLE FIRE ALARM SYSTEM NAC CIRCUITS VOLTAGE DROP CALCULATIONS Faternal Order of Eagles ZePhyrhills Pasco County FL BPS ArM Circuit Circuit Circuit Circuit draw #1 #2 #3 #4 each Level One'Level One Level TWo 'Spare North South Device Type 1 LHS3 75cd Wall Nlount Horn Strobe 0.105 0 1 0 0 2 'ASWP-2475W-FR 115W W.P. Wall Horn Strobe 0.173 0 1 1 0 3 LHSC3 75cd Ceiling ;Mount Horn Strobe 0.169 4 4 7 0 4 LHSC3 95cd Ceiling Mount Horn Strobe 0.267 0 0 0 0 5 ASWP-2475C-FR 115cd W.P. Ceiling Horn Strobe 0.173 L 2 0 0 0 6 LST3 75cd Wall Mount Visual 0.100 0 0 0 0 7 LSTC3 75cd Ceiinnc Nbunt Visual 0.155 0 1 1 0 8 0.000 0 0 0 0 0 0.000 0 0 0 0 0 0.000 0 0 0 0 0 0.000 0 0 0 0 PER CIRCUIT DRAW 1 1 1-022 1.109 1.511 0.000 TOTAL AMPS ON POWER SUPPLY 3.642 2.620 1.511 0.000 0.000 VOLTAGE DROP CALCULATIONS - Ckt. #1 Ckt. #2 AMP LOAD 1.022 1.109 - DISTANCE FROM SOURCE TO EOL 300 VDIROP 250 VDROP WIRE GUAGE 14 1.370 14 1.239 CIRCULAR MIL 4110 USABLE 4110 USABLE VOLTAGE DROP PERCENTAGE 6.71°10 19.030 6:07°l0 19.161 Ckt. #3 Ckt. #4 AMP LOAD 1.511 0 DISTANCE 360 VDROP 0 VDROP WIRE GUAGE 14 2.430 14 0.000 CIRCULAR MIL 4110 USABLE 4110 USABLE', VOLTAGE DROP PERCENTAGE 11.91°l° 17.970 0-000/0 20.400 NOTE: BATTERY CALCS DONE WITH CIRCULAR MIL METHOD VARIABLES AMP LOAD IS THE CURRENT DRAWN FROM A NAC CIRCUIT - IN AMPS DISTANCE - THE DISTANCE FROM SOURCE TO LOAD - IN FEET WIRE GUAGE - SEE CHART BELOW CIRCULAR MIL -- IS THE CROSS SECTIONAL AREA OF THE WIRE GUAGE CHOSEN VOLTAGE DROP PERCENTAGE -PERCENT OF VOLTAGE LOST VDROP - THE ACTUAL NUMBER OF VOLTS DROPPED ON CIRCUIT USABLE - VOLTAGE LEFT AFTER DROP VOLTAGE IS SUBTRACTED FROM SOURCE WIRE SIZE (AWG) _. _ 12 14 16 18 I 20 CIRCULAR MILS (C-M_) - 6530 4110 2580 1620 1020 COPRER RESISTANCE IS 10.8 OHM PER LM '1 IL-4 LINJ • )A53600 .10 OF :• Zw 12/04/2019 dd CONSULTING GROUP, INC. CA LICENSE #31 838 JITRGE J. SSALGAD130 P.E. #536013 2001 'TIZEWEL.L, CII2CL_E #1 509 ORLANDO, FL 32837 P.E. STAMP 71 Cn Lli LLJ 0') co O LO IO Ln C' J co LO LO r�C.0f W Co 00 O x I^� � NCO W CD CD O O Q pa co O 2 r -� W c C— o O r CD CC) M^ I� rT� N L J m f IHNf�' I--� M V' J CO O F-., 00 W > O Q O C\2 Co E, E- w Z O U Q o � O CQ W I4 W Q CQ O N pZ>_, 04 E O E ITS` V DRAWN BY: DQDD APPROVED BY: DATE: 11 /21 /19 SCALE: AS INDICATED PROJECT NO: LEVEL ONE FLR. PLAN NAC CKTS. VOLTAGE DROP CALCULATIONS 0 Cl) LLJ or_ LLJ FIRE ALARM SYSTEM DEVICE LEGEND SYMBOL DESRIPT10N COMMENT PRODUCT I.D. MOUNTING HEIGHT ELEC, BOX 17_ FIRE ALARM CONTROL VIGILANT SERIES VS1-RD 72" AFF TO TOP FRCP PANEL WITH DACT OF CONTAINER MFR. FIRE ALARM REMOTE VIGILANT SERIES RLCD-R 60" AFF TO TOP FAAP ANNUCIATOR PANEL OF CONTAINER MFR. FIRE ALARM REMOTE VIGILANT SERIES MIRBPS6A BESIDE FACP BPS POWER SUPPLY MFR. ADDRESSABLE MANUAL VIGILANT SERIES 42" TO 48" AFF 0 PULL STATION GSA-M278 DOUBLE ACTION NOTE 2 C 2 O ADDRESSABLE VIGILANT SERIES CEILING B SMOKE DETECTOR V-PD WITH K1-SB BASE MOUNT 2 ADDRESSABLE SUPP./ VIGILANT SERIES GSA -SD DUCT S/R RTN. SIDE DUCT DET. WITH SD-T60 SAMPLING TUBES MOUNTED D RT DUCT DETECTOR VIGILANT SERIES GSA -SD CEILING C REMOTE TEST SWITCH WITH SD-TRM MOUNT ADDRESSABLE VIGILANT SERIES PROVIDE DRY 0 MONITOR MODULE GSA-CT1 ENCLOSURES E ❑M ADDRESSABLE DUAL VIGILANT SERIES PROVIDE DRY E 2 MONITOR MODULE GSA-CT2 ENCLOSURES C R ADDRESSABLE VIGILANT SERIES PROVIDE DRY E RELAY MODULE GSA-CR ENCLOSURES � F SPRINKLER FURNISHED BY OTHERS FIELD LOCATE r-�-� FLOW SWITCH MONITORED BY NEW FRCP PER FLOOR PLANS D T SPRINKLER FURNISHED BY OTHERS. FIELD LOCATE TAMPER SWITCH MONITORED BY NEW FRCP PER FLOOR PLANS D WALL MOUNT WHEELOCK EXCEDER LHS3 SERIES 82" AFF TO HORN STROBE (*) CANDELA RATING BOTTOM OF LENS C CEILING MOUNT WHEELOCK EXCEDER LHSC3 SERIES CEILING HORN STROBE (*) CANDELA RATING MOUNT C CLG. MOUNT W.P. WHEELOCK ASWP-2475W-FR SERIES 82" AFF TO �WALL HORN STROBE 115 CANDELA RATING BOTTOM OF LENS WBB p WALL MOUNT W.P. WHEELOCK ASWP-2475C-FR SERIES 82" AFF TO HORN STROBE 115 CANDELA RATING BOTTOM OF LENS WBB WP CLG. CEILING MOUNT WHEELOCK EXCEDER LSTC3 SERIES CEILING C STROBE (*) CANDELA RATING MOUNT CLG. S�-1 FIRE ALARM 120VAC DITEK DTK-120HW SERIES FIELD LOCATED 120 CIRCUIT PROTECTOR AT FACP/BPS D MFR. DENOTES BACKBOX FURNISHED BY MANUFACTURER AFF DENOTES ABOVE FINISHED FLOOR WBB DENOTES WEATHERPROOF BACKBOX BACKBOXES REQUIRED BY OTHERS 2-1/8' 4» SQ 2-1/8" 1-1/2„ DEEP DEEP DEEP 4" SQ. 1-1/2" BLANK SINGLE 4-11/16" 4-11/16" OCTAGON EXT. RING PLATE GANG BOX SQ. BOX EXT. RING BOX BACKBOX SCHEDULE A - 4" BOX WITH SINGLE GANG RING B - 4" BOX WITH ROUND RING OR OCTAGON BOX C - 4" BOX 2-1 /8" DEEP WITH SGPR D - 4" BOX ADJACENT FLEX TO DEVICE E - 4" BOX 2 1/8" DEEP WITH EXTENSION BOX GENERAL NOTES SYSTEM INSTALLATION IN ACCORDANCE WITH 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE FLORIDA SPECIFIC ADDITION OF NFPA 1, THE FIRE CODE (2015) NATIONAL ELECTRIC CODE (2014 EDITION) NFPA 72 (2013 EDITION) NATIONAL FIRE ALARM SIGNALING CODE - FLORIDA SPECIFIC EDITION OF NFPA 101 NFPA 101 (2015 EDITION) FLORIDA ADMINISTRATIVE CODE 61 G15-32 ALL OTHER CODES MANDATED BY THE LOCAL AUTHORITY HAVING JURISDICTION 1) FIRE ALARM SYSTEM WIRING: STYLE B (CLASS B) INITIATION DEVICE CKTS. STYLE Y (CLASS B) NOTIFICATION APPLIANCE CKTS. STYLE 4 (CLASS B) ADDRESSABLE SIGNALING LINE 2) LOCKBOX TO BE MOUNTED OUTSIDE OF THE BUILDING WITHIN 6' OF PRIMARY ENTRANCE DOOR AND AT A HEIGHT NOT TO EXCEED 12' AFF NOR BE LESS THAN 8' AFF TO BOTTOM OF BOX. KEYBOX SHALL BE ZONED INDEPENDENTLY IF REQUIRED BY THE LOCAL AUTHORITY FIRE ALARM SYSTEM BATTERY CALCULATION VIGILANT SERIES VS 1 -RD (FACP) ITEM QTY DESCRIPTION STANDBY ALARM STANDBY ALARM per unit per unit Total Total A 1 MASTER CONTROLLER 0.155 0.204 0.155 0.204 B 1 REMOTE ANNUCIATOR 0.036 0.146 0.036 0.146 C 18 ADDRESSABLE DEVICES 0.0005 0.0005 0.009 0.009 D 1 FULL LOAD NOTIFICATION 0.000 3.750 0.000 3.750 E 3 AUX. 24VDC RELAY 0.000 0.015 0.000 0.045 TOTAL DRAW AMPS 0.200 4.154 STANDBY FOR 24 HOURS AMPS 4.800 ALARM FOR 5 MINUTES AMPS .347 TOTAL BATTERY IN AMPS REQUIRED 5.147 X 1.2 FACTOR 6.177 BATTERIES SUPPLIED 7.0 AMP HOUR NOTIFICATION CIRCUITS .FUSED AT 2.5 AMPS VIGILANT SERIES MIRBPS6A (PCPs) ITEM QTY DESCRIPTION STANDBY ALARM STANDBY ALARM per unit per .unit Total Total A 1 MASTER CONTROLLER 0.175 0.270 0.175 0.270 B NOTIFICATION CIRCUIT 1 0.000 1.022 0.000 1.022 C 1 NOTIFICATION CIRCUIT 2 0.000 1.109 0.000 1.109 p 1 NOTIFICATION CIRCUIT 3 0.000 1.511 0.000 1.511 E 1 NOTIFICATION CIRCUIT 4 (SPARE) 0.000 0.000 0.000 0.000 TOTAL DRAW AMPS 0.175 3.912 STANDBY FOR 24 HOURS AMPS 4.200 ALARM FOR 5 MINUTES AMPS .326 TOTAL BATTERY IN AMPS REQUIRED 4.526 X 1.2 FACTOR 5.432 BATTERIES SUPPLIED 7.0 AMP HOUR. NOTIFICATION CIRCUITS FUSED AT 3.0 AMPS FIRE ALARM FUNCTIONAL MATRIX: Ld L_ _j CONTROL UNIT ANNUNCIATION NOTIFICATION SUPPLEMENTARY o r U Q Z J J Q OO ¢ Z IN- � Z m O Z C.l) U � _ v~ i v' P.E. STAMP Jv 41 Qamm Li e • • � y ) - DRAWN BY: DQDD CD APPROVED BY: DATE: 11 /21 /19 5; cn 711 ULo cn j scALE: AS INDICATED PROJECT DEVICE .LEGEND BATTERY CALCS. RISER DIAGRAM FA-1 e • • � y ) - DRAWN BY: DQDD CD APPROVED BY: DATE: 11 /21 /19 5; cn 711 ULo cn j scALE: AS INDICATED PROJECT DEVICE .LEGEND BATTERY CALCS. RISER DIAGRAM FA-1 - DRAWN BY: DQDD CD APPROVED BY: DATE: 11 /21 /19 5; cn 711 ULo cn j scALE: AS INDICATED PROJECT DEVICE .LEGEND BATTERY CALCS. RISER DIAGRAM FA-1 WALK IN WALK IN GAS METER COOLER COOLER WALK IN UNIT UNIT FREEZER 00 0000 0000 .DLL LL D 00 4° ° 4 O WALK IN COOLER � w ° ° w w0 4 °D o 00000 WP �.LU o S1-2 °'0 D D o 115cd a ° M CLG. ° �< w¢ mw B w o�-o �00> < !;E < WALK IN F EZER 0 } U)wzw S1-3 115cd WP CLG. WALK IN COOLER S1-4 115cd CLG. WP ° 4 ° , ° B 0 U W X LU oIr ��6 m C) � p m ❑ LL � a = �Wm vi p = DRPY0120 z J FRYER 0 � a DRPY-0120 'w a Paz FRYER tea¢ 0 N. C) m I w DRPY-0120 w o m= FRYER GAS DRPY-0120 Uj w FRYER O U m z ¢ > :D m z Cn YU a = z z J o< w w a co 7) 2 X w aW o > O dz� of U) W p' w o a, wY mm % w w �< O� G m0 Q ° F_ ° A D 4 ° n NOTIFICATION SPACING BASED ON MAXIMUM SMOOTH CEILING HEIGHT OF 20'-0" AREA IS PROTECTED BY AN AUTOMATIC FIRE PROTECTION SPRINKLER SYSTEM MONITORED BY THE HOUSE FACP RINNAI MODEL CU160E NATURAL GAS ON DEMAND WATER HEATER UNIT#1 UNIT#2 LZ El 10'0" A.F.F. VERIFY HEIGHT 1,0 �\ D mz 0 �D o 0 m 00 0X mn mM �m F-1 C, 00z U_ c � w � O N r W m 6 x T o 0 a z CORNELIUS NORDIC UNDER COUNTER z o 0 CUBE ICE MACHINE 309LB PER DAY �D- 30" WIDE 30" DEEP 39" TALL a° 4 A % 36" X21" ICE BIN BY OTHERS P Du- Dom- D� Dom- D� O❑O GFI 00 S.S. PREP HAND WASH ABLE 60"X30" SINK COFFEE MACHINE WITH COLD WATER LINE AND DRAIN CONNECTION S1-5 75cd CLG. S.S. PREP TABLE 72"X30" S1-6 I EOLR 75cd 48"X30" SPRAY CLG. WASH SINK WITH GRINDER 36" WIDE HAND WASH 36" DEEP SINK DISHWASHER 60 AMP BRK 3P o0 UP 1.13 A u EOLR F EOLR T M 2 \ 1.14 A / STORAGE FAA P P,S 6" ABOVE PASS -THRU COUNTER S2-6 75cd CLG. 6" ABOVE PASS ~THRU COUNTER 1.8 2 D F S2-7 1.12 75cd TO FAC P rn BALCONY LINE ABOVE 96"X36" TABLE ELEVATOR S1-1 TO 75cd BPS CLG. MEETING AREA F] 1.7 TO FAC P MEETING AREA C R 1.9 PRIMARY ELEVATOR RECALL D,P C R 1.10 ALTERNATE ELEVATOR RECALL D,P C R 1.11 FIRE HAT WARNING LIGHTS WOMEN 7S� S2-5 115cd WP LEVEL ONE FIRE ALARM SYSTEM PLAN 1/4" = 11011 SCALE: 1/4" = 1'-0" S2-4 75cd CLG. TO BPS S2-1 75cd CLG. GFI S2-2 75cd CLG. STORAGE 0 POWER COMPANY TRANS U_ ELECTRICAL 1.2 C f MECHANICAL p ROOM 1.1 2 1 1-4(S ICIR11.3 AHU-1 2 R 1.5 N AH SUSPENDED FROM (LING WITH PAN BELOW U S2-3 75cd CLG. 1.6 O STORAGE MEN SOUND OVERRIDE RELAY BPS FACP n TO -t ►' ' FAC P FIRE ALARM SYSTEM CABLE LEGEND MARK DESCRIPTION PURPOSE A GENESIS SERIES 4506 2 COND. 18AWG FPLP INITIATION CIRCUIT B GENESIS SERIES 4513 2 COND. 14AWG FPLP NOTIFICATION CIRCUIT D GENESIS SERIES 4506 2 COND. 18AWG FPLP ADDRESSABLE SIGNALING LLINE CIRCUIT P GENESIS SERIES 4513 2 COND. 14AWG FPLP 24VDC POWER CIRCUIT R GENESIS SERIES 4506 (2) 2 COND. 18AWG FPLP DUCT DETECTOR REMOTE TEST SWITCH S GENESIS SERIES 4506 2 COND. 18AWG FPLP SERIAL LINE CKT. TO ANNUCIATOR FPLP DENOTES FIRE POWER LIMITED PLENUM CABLE FIRE ALARM SYSTEM NAC CIRCUITS VOLTAGE DROP CALCULATIONS Faternal Order of Eagles Zephyrhills Pasco County FL BPSArnp _ Circuit Circuit Circuit Circuit draw #1 #2 #3 #4 each Level One Level one Level Two Spare North south Device Type 1 LHS3 75cd Wall Nbunt Horn Strobe 0.105 0 1 0 0 2 'ASWP-2475W-FR 11Scd W.P. Wall Horn Strobe OA73 0 1 1 0 3 LHSC3 75cd Ceiling Mount Horn Strobe 0.169 4 4 7 0 4 LHSC3 95cd Ceiling Mount Horn Strobe 0-267 0 0 0 - 5 ASWP-247SC-FR 115cd W.P. Ceiling Horn Strobe 0.173 2 0 0 0 6 LST3 75cd Wall Mount Visual 0.100 0 0 0 0 . 7 LSTC3 75cd Ceiling Mount Visual 0.155 0 1 1 0 0-000 0 0 0 0 fl 0.000 0. 0 0. 0 0 0.000 0 0 0 0 0 0.000 0 0 0 0 PER CIRCUIT DRAW 1.022 1.109 1.511 0.000 TOTAL AMPS ON POWER SUPPLY 3.642 2.620 1.511 0.000 0.000 VOLTAGE DROP CALCULATIONS Ckt. #1 Ckt. #2 AMP LOAD 1.022 1.109 DISTANCE FROM SOURCE TO EOL 300 VDROP 250 VDROP WIRE GUAGE 14 1.370 14 1.239 CIRCULAR MIL 4110 USABLE 4110 USABLE f VOLTAGE DROP PERCENTAGE 6:71% 19.030 6.07% 19.161 Ckt. #3 Ckt. #4 AMP LOAD 1.511 0 DISTANCE 360 VDROP 0 VDROP WIRE GLIAGE 14 2.430 14 0.000 CIRCULAR MIL 4110 USABLE 4110 USABLE VOLTAGE DROP PERCENTAGE 11.91% 17.970 U_00% 20.400 NOTE: BATTERY CALCS DONE WITH CIRCULAR MIL METHOD VARIABLES _ . AMP LOAD IS THE CURRENT DRAWN FROM A NAC CIRCUIT - IN AMPS DISTANCE - THE DISTANCE FROM SOURCE TO LOAD - IN FEET WIRE GUAGE - SEE CHART BELOW _ CIRCULAR MIL -- IS THE CROSS 5ECT10NAL AREA OF THE WIRE GUAGE CHOSEN. VOLTAGE DROP PERCENTAGE - PERCENT OF VOLTAGE LOST VDROP - THE ACTUAL NUMBER OF VOLTS DROPPED ON CIRCUIT USABLE - VOLTAGE LEFT AFTER DROP VOLTAGE IS SUBTRACTED FROM SOURCE WIRE SIZE (AWG) I 12 14 16 18 20 CIRCULAR MILS (C-M-)_ 6530 4110 2580 1620 1020 COPRER RESISTANCE IS 10.8 OHM PER LM JJ CONSULTING GROUP, INC. CA LICENSE #31 839 aJ,CRGE J. SA.LGAD❑t P.E. #i 5E3G:OO 21301 TIZE'WELL GLRCLE #1 SE39 DRLANDO, FL 32837 P.E. STAMP 71 LLJ LLJ O 't LO � 1.' J c LO 10 I co (D x /�'� W F I CO O O co1O � � (24 MM W 60 W I W E-1 a0 E-1 W O H u co O 1, 4 0 Co O Q I C''J co 0 I � 00 o w H� O Q O 1.4 LO co E- W o O Q U � N O a w O �1214 W Q � � � 0 N Ce, E O f- U DRAWN BY: DQ D D APPROVED BY: DATE: 11 /21 /19 SCALE: AS INDICATED PROJECT NO: LEVEL ONE FLR. PLAN NAC CKTS. VOLTAGE DROP CALCULATIONS FA-2 NOTIFICATION SPACING BASED ON MAXIMUM SMOOTH CEILING HEIGHT OF 20'-0" AREA IS PROTECTED BY AN AUTOMATIC FIRE PROTECTION SPRINKLER SYSTEM MONITORED BY THE HOUSE FACP LEVEL TWO FIRE ALARM SYSTEM FLOOR PLAN 1/4" = 1' 0" SCALE: 1/4" = 1'-0" `r%olliAtliilf/Jffl SAC j41 `�► .`� ``' `r 0 © 53600 f '. 'TATE OF Ott: rrj"11 1 1 00 o 12/04/2019 Jd CONSULTING GROUP, INC. CA LICENSE #31 838 J❑FRGE J. SAILGAIDO, P.E. #53600 2(1301 TIZEINELL C1RG`LE #1 5139 DRLAN D"O, FL 32837 P.E. STAMP 71 LLJ 0-1 • • • • • � e • • RV F—I 1—1 W O C\2 L7�o r� c J W I� V TOT , V 1 ^I O �1 \ O W Q r�� �1 FF-Ttt-i�l. O N N Fxq H U DRAWN BY: D Q D D APPROVED BY: DATE: 1 1 /2 1 /1 9 SCALE: AS INDICATED PROJECT NO: LEVEL TWO FLOOR PLAN It& Fa-3