HomeMy WebLinkAbout7403 Gall BlvdPT SOLUTIONS ZEPHYRHILLS OFFICE 7403 GALL BOULEVARD ZEPHYRHILLS, FLA 33541 INDEX OF DRAWINGS A-0 COVER SHEET A-1 CONSTRUCTION, DEMO, REFLECTED CEILING PLAN A-2 INTERIOR DETAILS F-1 FINISHES, FURNITURE PLAN M-1 FLOOR PLAN & SCHEDULES M-2 SPECIFICATIONS & DETAILS E-1 FLOOR PLANS - POWER & LIGHTING E-2 SPECIFICATIONS E-3 ENERGY COMPLIANCE REPORT P-1 FLOOR PLANS - WATER, WASTE/ VENT & ISOMETRIC P-2 SPECIFICATIONS, DETAIL AND SCHEDULES ARCHITECT GEORGE H. GRANT 4597 WIEUCA ROAD, ATLANTA, GA 30342 404 875.6622 EMAIL: SHEFFERGRANT@SHEFFERGRANT.COM MEP ENGINEERS PROFICIENT ENGINEERING, INC 6991 PEACHTREE INDUSTRIAL BLVD BLDG 700 PEACHTREE CORNERS, GA 30092 HEYOUNG LEE 404.330.9798 EMAIL: HLEE@PEIATL.COM TENANT PT SOLUTIONS HOLDING CO. 1990 VAUGHN RD, SUITE 330,KENNESAW, GA 30144 JOHN PROVOST, 505-514-9373 CELL BUILDING OWNER & REPRESENTATIVE ZEPHYRHILLS MERCHANTS SQUARE LLC MARY MILLER MMILLER@LCADEVELOPMENT.COM 407.367.0920 SCOPE OF WORK TENANT FIT OUT FOR NEW TENANT IN TWO EXISTING TENANT SUITES WHICH WILL BE COMBINED. MINOR DEMOLITION, CONSTRUCTION OF NEW INTERIOR PARTITIONS AND DOORS, MILLWORK, POWER AND LIGHTING, AND HVAC DISTRIBUTION. EXISTING RESTROOMS ARE TO BE MODIFIED TO MEET CURRENT ADA. NEW PAINT AND FLOOR FINISHES. CODE NOTES AND BUILDING INFO 1. APPLICABLE CODES, ALL CONSTRUCTION TO MEET THE FOLLOWING FLORIDA BUILDING CODE 2017, 6TH EDITION 2017 FLORIDA BUILDING CODE - MECHANICAL, 6TH EDITION 2017 FLORIDA BUILDING CODE - PLUMBING, 6TH EDITION 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, 6TH EDITION 2011 NATIONAL ELECTRICAL CODE 2012 INTERNATIONAL FIRE CODE 2012 LIFE SAFETY CODE - NFPA 101 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, 6TH EDITION 2010 ADA STANDARDS FOR ACCESSIBLE DESIGN 2. ALL NEW SIGNAGE SHALL CONFORM TO THE VIRGINIA ACCESSIBILITY CODE FOR BUILDINGS AND CONSTRUCTION. REST ROOM SIGNS SHALL INCLUDE BOTH THOSE WITH RAISED AND BRAILLE CHARACTERS AND PICTORIAL SYMBOL SIGNS WITH LETTERS BELOW. SIGNS TO PERMANENT ROOMS AND SPACES EXCEPT THOSE SOLELY FOR MAINTENANCE INDENTIFICATION SHALL INCLUDE RAISED AND BRAILLE CHARACTERS. ALL OTHER SIGNS SHALL CONFORM TO THE CODE FOR WIDTH/HEIGHT RATIO AND STROKE/HEIGHT RATIO. 3. FIRE EXTINGUISHERS SHALL BE PROVIDED IN ACCORDANCE WITH IFC, MIN 1 PER FLOOR WITH MAX. TRAVEL TO ANY EXTINGUISHER OF 751, SIZED A MINIMUM OF 2A10BC. PROVIDE AND INSTALL FIRE EXTINGUISHER BRACKET MAX 48" FROM FLOOR TO HANDLE. 4. OCCUPANCY TYPE: EXISTING BUSINESS GROUP B 5. CONSTRUCTION TYPE PER IBC: TYPE IIB SPRINKLERED 6. TENANT AREA: 2,350 SQUARE FEET 7. OCCUPANT LOAD - 24 PERSONS 2,350 SF @ 100 SF/PERSON = 24 PERSONS GENERAL NOTES 1. DO NOT SCALE FROM THESE DRAWINGS. 2. CONTRACTOR SHALL REVIEW ALL DRAWINGS/SPECIFICATIONS AND VERIFY ALL DIMENSIONS/CONDITIONS AT SITE AND NOTIFY THE ARCHITECT OF ANY DISCREPANCIES OR OMISSIONS BEFORE PROCEEDING WITH THE PROJECT. 3. CONTRACTOR TO COMPLY WITH ANY LANDLORD RESTRICTIONS. CONTRACTOR SHALL COMPLY WITH OWNER GUIDELINES REGARDING CLEANLINESS OF SITE, TRANSPORTATION OF BUILDING MATERIALS ETC. 4. ALL EXPOSED ELECTRICAL FIXTURES, SUCH AS EXIT LIGHTS, FIRE ALARM, WALL OR CEILING MOUNTED CLOCKS, ETC. SHALL BE CENTERED ON ARCHITECTURAL FEATURES AS INDICATED ON REFLECTED CEILING PLAN. 5. THE ARCHITECTS REVIEW OF SHOP DRAWINGS, PRODUCT DATA, AND OR SAMPLES SHALL NOT RELIEVE THE CONTRACTOR OR HIS SUBCONTRACTOR OF RESPONSIBILITY FOR ANY DEVIATION FROM THE REQUIREMENTS OF THE CONTRACT DOCUMENTS, NOR SHALL ANY SUCH REVIEW RELIEVE RESPONSIBILITY FOR ANY ERROR AND/OR OMISSIONS IN THE SUBMITTALS., 6. CONTRACTOR SHALL BE RESPONSIBLE FOR THE OFF SITE DISPOSAL OF ALL CONTAINERS, PALLETS, CONSTRUCTION DEBRIS. NO DISPOSAL ON SITE IS PERMITTED. PLACEMENT OF CONSTRUCTION DUMPSTER MUST BE COORDINATED WITH BUILDING MANAGEMENT. TRASH REMOVAL FROM THE SITE SHALL BE DONE ON A DAILY BASIS WITH ALL PUBLIC AREAS KEPT IN A CLEAN AND PRESENTABLE APPEARANCE AT ALL TIMES. PLUMBING FIXTURE CALCULATIONS 1 WATER CLOSET PER 25 FOR FIRST 50 =1 2 PROVIDED 1 LAVATORY PER 40 =1 2 PROVIDED 1 SERVICE SINK 1 PROVIDED 51 LIFE SAFETY PLAN A-0 11811=1'-01e CRESTVIEW H CAROLE ACRES THE I TMerchants Square RL SPANISH ZEP TRAILS VILLAGE a C VALLEYDALE RO DIXIE HEIGHT ASSOCIATION INC 3e1 Eland Blvd ENTW00D ZEPHYR PARK LOCATION PLAN Pretty Pond Rd Pretty Pond Rd Tractor Supply Co Sonic Drive -In Iis Department Store z CD 0 NOTES Popeyes 1p Louisiana Kitchen sat 39 MedIcal Arts Ct Medical Arts Ct 1. MAXIMUM TRAVEL DISTANCE ALLOWED IS 200'. 2. ACTUAL TRAVEL DISTANCE IS LESS THAN 60' Goo'gle KEY PLAN Dairy Queen C ba W zgzp 5E ?zu0 a� 0 pV[ 0F0 aw��w fm�+7 GV cc to a0o�r u o 2=wa. '3 W N"=.Oz 'azao O GEORGE 1-I. GF AR 96894 /y/ERED AR6 r� V W4 CV b Fassill z M0 Q O V O Z �1 <c F 9 Z � <[ LL LL w C\J CO �w=`- Z ti °O 0E--o O< t F� 'Uw << w OC IL LL �_ � 0) L0 AllJ It n oo� mil. ow's PT SOLUTIONS S FAO ( CC `ArfO�A Rf�A g �PCY ORSCk Cj�Ty�� 4/CC /AIG OI �pRSI.gf��N CFS 2EP�yy�lj`8 G REVI WED FOR CODE COMPLIANCE�g' UWVMU�. INC. IIIPWM Fd~"60.' s+a 11s Theft PfM* EbuM tree rr0v*ftd for s+rvA xtM—e w die fky; a tM00 Cods lCeftft96 ftchoniceyAumblimp, Pr FsboaY i.arre y 1011, NFOA 1 U09brnA Fire Cedsh Firs PnAeadsn Cedes SOR 6e, swd tore Nalioned rd- Wdeaf Go" so adopted 6V the State oi' Fioahla. Our Plan ih,lewmt these also* is Fan sae"t to isafiea 10&3.5 cf the Fioeldo C W440 a" Asotade Mary Item outride of the *Wind codes nor *aeon It di kwe 4heter ITA haMderlraia► ax"epAnaas wNkpoiriftlions at pass® or any dbiev state ow Jecal4 r nydatlen trttsAnstion or the paloreawwo of consftwe.thm trfeaeeleMire If —A , C3 * U) Z o ~ L 0�� CD a �NUj tiN J 4.10.18 1 DEMO PLAN1-011 DEMOLITION NOTES WALL LEGEND R.C.P. LEGEND 1. DEMO WALLS, DOORS AND MILLWORK AS INDICATED.. DEMO ALL EXISTING FLOORING INCLUDING CERAMIC TILE AND BASE. DEMO ALL PLUMBING NOT USED IN THESE PLANS. 3. MAINTAIN ALL EXISTING RATINGS ON EXISTING WALLS. 4. EXISTING CEILING GRID TO REMAIN. TILE AND LIGHTING IS TO BE DEMOLISHED. SEE ELECTRICAL DRAWINGS. 5. DEMO ALL EXISTING FINISHES INCLUDING MIRRORS. 0 EXISTING WALL WALL OR ITEM TO BE DEMOLISHED 2 REFLECTED CEILING PLAN A-1 1 /8"=1'-0" 0 4'-0" SUSPENDED LED @9-6" A.F.F. 0 2'-0" LED PENDANT FIXTURE @ r A.F.F. 0 DOWNLIGHT ® HVAC SUPPLY ElHVAC RETURN v EMERGENCY FIXTURE FIXTURE cxEMERGENCY W/ EXIT SIGNAGE 0 EXHAUST FAN CEILING GRID R.C.P. NOTES 1. EXISTING CEILING GRID IN SUITE 7401TO REMAIN. EXTEND EXISTING GRID AS REQUIRED FOR CONTINUOUS GRID. PROVIDE NEW TILE: ARMSTRONG, CIRRUS, 2x4 SCORED TO 1'x1' 2. DEMOLISH EXISTING LIGHT FIXTURES AND PROVIDE NEW FIXTURES AS INDICATED. SEE ELECTRICAL DRAWINGS. NEW FIXTURES TO BE 8'-0"A.F.F. 3. SEE MECHANICAL PLAN FOR NEW DIFFUSERS AND EQUIPMENT. NOTE NEW CEILING HEIGHT AT 10'-0" IN SUITE 7403 AND MAKE ANY ADJUSTMENTS REQUIRED. 4. RELOCATE EXISTING SPRINKLER HEADS AS REQUIRED PER NFPA 13. O to O T 2'-0" - r--T, 3'-211 MIN. 0 uo OTE 9 A 42 8 7'-6" FURR TO ALIGN - WOMEN O a O 0 11 MEN - il'0000,0 �lmmlmlilm-1 /I I I 2 3 A-2 j 12'L I I I 2�-67% LL 8 42 T co (V O i R ON OPENING 3 PLAN TEL./ `ocoMP_ 3'-8" EG 0 O M 0 L 0o s G a W z�zo 0 F- oa�n o od axoww c� zoo�- iZwo=�_ LLJ p¢t:x 3aw3z 0 �Fwa� w m3x W x�ozz C7 'azao O 0 F Flop' ZGEORGE. GR p- 894L�l) Al DOOR NOTES Q STANDARD 3'-0" x 7'-0" FLUSH SOLID CORE PAINT GRADE WOOD DOOR WITH PASSAGE SET AND WALL STOP. PAINTED METAL FRAMES. ® STANDARD 3'-0" x 7'-0" PAIR FLUSH SOLID CORE PAINT GRADE WOOD DOOR WITH PRIVACY SET AND WALL STOP. PAINTED METAL FRAMES. ® STANDARD 3'-0" x 7'-0" FLUSH SOLID CORE PAINT GRADE WOOD DOOR WITH LOCK SET AND WALL STOP. PAINTED METAL FRAME. ® EXISTING DOOR AND HARDWARE TO REMAIN. ALL HARDWARE, MOUNTING HEIGHTS, AND ITEMS RELATED TO HANDICAP ACCESSIBILITY STANDARDS ARE TO CONFORM TO FLORIDA ACCESSIBILITY CODE, 2010. CONSTRUCTION NOTES 1. ALL DIMENSIONS ARE TO FACE OF EXISTING WALL OR FACE OF GYP BOARD. G.C. TO CONFIRM OVERALL DIMENSIONS BEFORE STARTING ANY WORK. REPORT ANY DISCREPANCIES TO ARCHITECT BEFORE PROCEEDING. 2. PATCH AND REPAIR EXISTING WALLS AS NECESSARY FOR PAINT INCLUDING ALL POINTS OF DEMOLITION. MAINTAIN ALL EXISTING FIRE RATINGS ON EXISTING WALLS. 3. G.C. TO PROVIDE NEW FIRE EXTINGUISHER AS REQUIRED BY CODE. 4. G.C. TO PROVIDE TP HOLDERS, 24"x36" BOBRICK MIRROR, GRAB — BARS, TOWEL AND SOAP DISPENSERS AT NEW ADA TOILET ROOMS. PROVIDE STANDARD BLACK ADA'MEN' AND'WOMEN' SIGNAGE. PROVIDE STANDARD TOWEL DISPENSER AND SOAP — DISPENSER AT HAND SINK. S. PROVIDE F.R. BLOCKING AT ALL WALL MOUNTED T.V. LOCATIONS 7'-0" A.F.F. T.V. IS N.I.C. 6. PROVIDE 2 ROWS OPEN VINYL WRAPPED WIRE SHELVING 12"D AT LAUNDRY. (@36", 60" A.F.F.) 4 ROWS 16" D VINYL WRAPPED WIRE SHELVING AT LINEN CLOSET. (@24", 42", 60 75" A.F.F.) 7. PROVIDE 48"x48"x %" PAINTED F.R. PLYWOOD BACK BOARD AT REAR WALL OF TEL/COMP CLOSET. QUAD OUTLETS AT STANDARD HEIGHTS BELOW. 8. PROVIDE 18"D 34"H PL LAM COUNTERTOP W/ SPLASH 9. G.C. TO SECURELY INSTALL BRACKETS FOR AED AND RACK AT HYDROCLLATOR (SEE F-2). BRACKETS PROVIDED BY TENANT. 10. WRAP EXISTING COLUMNS WITH %" GYP BD IN MINIMAL DIMENSIONS ON 3/4' HAT CHANNEL. WALL LEGEND ALL NEW WALLS SHALL BE 5/8" GYP ® BRD ON EA SIDE OF 3-5/8" 25 GA STL STUDS @ 24" CC EXTEND TO CEILING LOW WALL - 3-5/8" 25 GA STL STUDS @ 24" O.C. TO HEIGHT INDICATED (IN INCHES). TOP OF ALL WALLS TO BE GYP BOARD UNLESS NOTED OTHERWISE. EXISTING WALL CV d' cn 0 h--I c O QU V/ Z W Ia- Z C� �LLLN QLL W 19 W=`{' z @ °D Q Z 't W "+ w w Q V W _W LL- W W �: Lu _ ti to Lo PT SOLUTIONS VJ Z O V Q co V- W J D O j �. JJmJ O 2 cM = W IV W N I,-- N A-1 4.10.18 V Q W z�za I_ GZ�- owoa a ��aw � QQ� = ZdQ=F 10'-0" ELAMINE INTERIOR cc <� PROVIDE FINISHED BACK AND SIDES ROVIDE PL-5 FINISHED BACK AND SIDES o m Ul =�oZLL io s SOLID SURFACE TO 12'-0" SOLID SURFACE TO FOR ALL EXPOSED ELEMENTS FOR ALL EXPOSED ELEMENTS ¢ Z a - SS-2��S-2 12' 0" //710 s 4'-0" 4'_0„ L-1 - KEDr7 8 LA ERAL FILES OF F F( j)R�Oq o e OPEN---7OPEN / ADJ SHELF EOARE96894�� ' — —LOCKED ' )c/3'-9" N N _0DRAWERT-O Fv °-2" Ca RED AR 1 ELEVATION 2 REAR ELEVATION 3 ELEVATION 4 ELEVATION A-2 1 /2"=1'-0" A-2 1 /2"= V-0" A-2 1 /2 11-0" A-2 1 /2"=1'-O" T-0" 2'-0" F-I-i N q SOLID SURFACE TOP 2 -0 M SOLID SURFACE 2'-0' L O M M OWAVE SHELF iv 2'-6 (PL-2 @ BREAK) _ �.� co r SS-1 TOP N TOP _ O r;7� r - N Q ' HEAVY DUTY DRAWER _ r; T 1 C� Z GLIDES `° 4" WIRE PULLS `,/ PL-2 X" REVEAL 4" WIRE PULLS z m L-1 FINISHED � L-1 FRONT AND SIDES PL -1 FRONT & SIDES m U PROVIDE MELAMINE ALL BACK AT Z WRAP EXPOSED HOT d e (PL-3 @ BREAK) INTERIOR SURFACES RECEPTION DESK W N 04 WATER LINES, WASTE u) Q LINE AND P-TRAP W/ PROVIDE MELAMINE ALL a Q LL CU " PL-4 BASE INTERIOR SURFACES m SIDESRONT & cv _ ARMAFLEX INSULATION _ _ (TYP) ® ® W 04 ADJUSTABLE 3/4" UB PL-3 � = ADJUSTABLE 3/4" TOE SPACE AT Z co I 3' 0" " 1' SHELF SHELF _....____ RECEPTION DESK IT ADA SINK BASE— -- -----_._. Z d' �r 3 d , V.C.T. INSIDE FLOOR er d 3 O Q 5 ELEVATION 6 ELEVATION 7 SECTION 8 SECTION v 0 A-2 1/2 "=1'-0" A-2 1 /2"_ 1'-0" A-2 3/4"=1'-0" A-2 3/4"=1'-0" LL W w _ LL � Lu CD Cn Lo SS-2 2'-3" SS-2 ULLNOSE 3" GROMMET (3 MELAMINE _0.. 2" GROMMET EA SIDE 2'-0" SS GROMMET EA I SS-2 0 0 0 0 �BULLNOSE WIRE MANAGEMENT L-4 co STRAPS `O o -4 SIDE WALL o CV N I I t j� PT SOLUTIONS j I A2 SECTION A2 SECTION 3/4 —1 -0 3/4 =1-0 NOTES 1. G.C. TO CONFIRM ALL DIMENSIONS FOR MILLWORK PRIOR TO FABRICATION f^ AND PROVIDE SHOP DRAWINGS OF ALL V J ITEMS FOR APPROVAL BY ARCHITECT. Z 2. PROVIDE 5 THERAPY CABINETS (6/A-2) W i] SEE PLAN FOR EXACT LOCATIONS. O M 3. ALL CABINET HARDWARE TO BELo LL � Q HEAVY DUTY INCLUDING HINGES, LI_ W J BRACKETS AND STANDARDS AND PULLS. O ? LL. WALL TILE PROVIDE HANGING RAILS FOR LATERAL U) O � 1 FILE CABINET DRAWERS. J J m J 4. ALL EXPOSED SURFACES, INTERIOR 24X36 MIRROR AND EXTERIOR, ARE TO BE COVERED �O w J � SOAP DISP--� 3'-3" - T-5" 18 GRAB BAR WITH LAMINATE OR SOLID SURFACE V j = _ 60" min p � PAPER TOWEL 1 °-0" 42" GRAB DISPENSER 16"-18" MAX _ N n� N 36" GRAB BAR BAR 2 ��� TOILET PAPER WRAP EXPOSED w DISPENSER HOT WATER LINES, U- WASTE LINE AND O �" _ TOILET PAPER P-TRAP W/ �¢ _ o U - M DISPENSER ARMAFLEX �' Z M o ` ' INSULATION (TYP) `' O 7"-9" `3' N O W ch N iM Z �E V I E W E 1 0 91 m � r COMPLIANCE EgIMMUENGEMNSSap! CE 9NCo A-2 11 ELEVATION 12 ELEVATION 4.10.18 A-2 1 /2"=1'-0" A-2 1 /2"=1'-0" 3'-9 N ih 3'-9" ,:. 1 � 1 ..VIES I YIf FINISH NOTES 1. PAINT DOORS P-3 INCLUDING REAR EXIT DOOR. PAINT FRAMES TO MATCH ADJACENT WALL COLOR, SEMI GLOSS. 2. PAINT ALL WALLS P-1 UNLESS NOTED OTHERWISE 3. PROVIDE ROPPE # 177 %a" TO %" BLACK FOR CARPET TILE TO LVT. 4. RUBBER BASE ALL WALLS EXCEPT TOILET ROOMS WHICH ARE TO RECEIVE TILE COVE BASE ALL WALLS. 5. ALL METAL FINISHES (DOOR HARDWARE, BATHROOM ACCESSORIES, MILLWORK ITEMS ETC.) TO BE BRUSHED ALUMINUM. 6. PAINT GYP BD CEILINGS CEILING WHITE. 7. PROVIDE BLINDS AT ALL WINDOWS. FINISH LEGEND PAINT P-1 SHERWIN WILLIAMS SW7006 EXTRA WHITE, EGG SHELL P-2 SHERWIN WILLIAMS PRE CATALYZED WATER BASED EPDXY SW7072 ONLINE, SEMI GLOSS FINISH P-3 (DOOR$) SHERWIN WILLIAMS SW6989 DOMINO, SEMI GLOSS PLASTIC LAMINATE: PL-1 WILSONART 1573-60 FROSTY WHITE (THERAPY CABINETS) PL-2 WILSONART 4760-60 MYSTIQUE NIGHT (COUNTER TOP AT BREAK) PL-3 WILSONART 4810-60 TITANIUM EV (CABINET FRONTS AT BREAK) PL-4 WILSONART 1570K-01 WHITE, GLOSS FINISH WITH AEON (RECEPTION DESK FRONTS) PL-S WILSONART 1570-60 WHITE (RECEPTION REAR CABINET FRONTS) SOLID SURFACE SS-1 CORIAN TERRA COLLECTION: PLATINUM (THERAPY CABINETTOPS) (ALTERNATE: AVONITE 9010 STORMY GRAY POLISHED) SS-2: DUPONT ZODIAQ, COLOR; SNOWDRIFT. (DESKTOPS) (ALTERNATE: AVONITE 7502 AVALANCHE POLISHED) WALL TILE: CROSSVILLE, COLOR BY NUMBERS, WT02 TEA FOR TWO 4"x8", STACKED. (FULL HT - ONE WALL WITH BASE TO MATCH) USE SAME COLOR BASE AT PAINTED WALLS. GROUT: 44 BRIGHT WHITE. CARPET TILE CT-1: MOHAWK GROUP, ARTISANAL, THREADED CRAFT, COLOR DUSK 7879, 24"x 24" MODULOR, INSTALL MONOLITHIC PERPENDICULAR TO ENTRY CT-2 (ACCENT 1) : MOHAWK GROUP COLOR BEAT, COLOR 555 MOROCCAN TILE, 24"x24" CT-3 (ACCENT 2) : NOT USED ASTRO TURF: NOT USED LUXURY VINYL TILE: LVT-1 MOHAWK GROUP, LIVING LOCAL GLUE DOWN, STYLE C2039,958 TWO TONE, 6"X48" INSTALL PARALLEL TO ENTRY RUBBER BASE: ROPPE, 100 BLACK, 4" COVE BASE. WINDOW COVERINGS: GRABER LIGHTWEAVES SOLAR SHADE 3% COLOR TBD P-2 LVT-1 _ WT-1 - i low is i ------ ---� ---_ -- - ----- ----------,,tom O 11L, I P-1 I LVT P-2 iffm im L x LVT P-1 CT-1 Kam x CITE 9 "l] OBI FURR TO ALIG WOMEN MEN 0 x HAUSMAN TEU COMP EVAI- H I LO HI LO W 0 z 0 m W C) m - Iii-Iffil, Irlrq -- ��;,. ■ .� 1 FURNITURE NOTES 1. ALL FURNITURE AND EXERCISE EQUIPMENT IS N.I.0 UNLESS NOTED OTHERWISE ON THIS DRAWING. FURNITURE LAYOUT IS PROVIDED FOR INFORMATION AND COORDINATION ONLY. 2. REFRIGERATOR, MICROWAVE AND FUTURE WASHER/ DRYER ARE N.I.C. . 3. TVS, SIGNAGE AND GRAPHICS SUPPLIED AND INSTALLED BY OTHERS. EO F FLO- 9 GEORGE H. GI AR 96894 � 11 �� r ,6),4 U N V, O M p U dZ Q I— Z w N ~LLLL CO Q W T Ll1 Lo ) P— Z @ 00 d" Q Z d- OQ w w Q UIx 5 W W LL L- le PT SOLUTIONS U) Z o� U¢� a I-- u- W I D ZLL ) I o 'u) —m O = ;� U) _ 0 M wow 1 FINISH PLAN F-1 1 W'=V-0" 1 FURNITURE PLAN F-1 1 f8"=1'-0" F-1 4.10.18 I=AN 5ChEDULE MAX. BASIS REMARKS MARK DUTY TYPE CFM E.S.P. MOTOR DRIVE NOISE CONTROL OF DESIGN. I 2 3 4 5 G (IN WG) (Wlhp) (SONES) BY MODEL EF- I EXHAUST CEILING CABINET 100 0.5 100 DIRECT 2.0 THERMOSTAT GKEENHECK SP X X X INTERLOCK WITH EF-2 EXHAUST CEILING CABINET 100 0.5 100 DIRECT 2.0 GREENHECK SP X X X MICROWAVE NOTES (APPLY TO ALL): REMARKS (APPLY AS SCHEDULED):. A. SEE ELECTRICAL PLANS FOR POWER CHARACTERISTICS 1. FAN SPEED CONTROLLER. B. DESIGN IS BASED ON PRODUCTS BY GKEENHECK. ACCEPTABLE 2. FACTORY DISCONNECT SWITCH/PLUG. ALTERNATES SHALL BE BY LOKEN-COOK, TWIN -CITY, PENN BARRY. 3. GRAVITY BACKDKAFT DAMPER. LEGEN D SYMBOLS DESCRIPTION X I DIFFUSER, GRILLE, REGISTER OK LOUVER TAG X2 X I = TYPE, X2 = CFM POSITIVE PRESSURE (AIK GOES OUT) DIFFUSER OK KEGI5TEK, 4-WAY AIR PATTERN (UNLESS OTHERWISE NOTED) zNEGATIVE PKE55UKE (AIR GOES IN) GRILLE POSITIVE PRESSURE AIRFLOW (TYP. SUPPLY) -4• NEGATIVE PKE55UKE AIRFLOW (TYP. KETUKN/EXHAUST) 1111111 FLEXIBLE DUCT MANUAL VOLUME DAMPER (MVD) VERTICAL (TYP. WALL) FIRE DAMPER IIFD FSD VERTICAL (TYP. WALL) COMBINATION FIKE/SMIOKE DAMPER y HORIZONTAL (Tr'P. FLOOR/CEILING) FIRE DAMPER FD HORIZONTAL (TYP. FLOOR/CEILING) COMBINATION FIKE/5MOKE PSD DAMPER OT THERMOSTAT O HUMIDISTAT O REMOTE TEMPERATURE 5EN50K INTERNALLY LINED DUCT DUCT UP DUCT UP DUCT DOWN SUPPLY DUCT ABBREVIATIONS AFF ABOVE FINISHED FLOOR MA MAKE-UP AIR AHU AIK HANDLING UNIT MAU MAKE-UP AIR UNIT CO2 CAKBON DIOXIDE MAV MANUAL AIR VENT D CONDENSATE DRAIN MBH 1 ,000 BTU PEK HK DB DRY BULB MFCU MINI FAN COIL UNIT EA EXHAUST AIR MHP MINI HEAT PUMP EAT ENTERING AIRTEIVIPERATUKE MVD MANUAL VOLUME DAMPER EDH ELECTRIC DUCT HEATER. NC NORMALLY CLOSED El' EXHAUST FAN NO NORMALLY OPEN ESP EXTERNAL STATIC PRE55URE OA OUTSIDE AIR EWH ELECTRIC WALL HEATER OBD OPP05ED BLADE DAMPER F DEGREES FAHRENHEIT PIU POWER INDUCTION UNIT FCU FAN COIL UNIT RA RETURN AIK FD FIRE DAMPER KH RELIEF HOOD FSD COMBINATION FIRE/SMOKE DAMPER RTU ROOFTOP UNIT H HUMID15TAT SA SUPPLY AIR IH INTAKE HOOD 5P STATIC PKE55UKE LAT LEAVING AIR TEMPERATURE UC UNDER CUT DOOR LWT LEAVING WATER TEMPERATURE VAV VARIABLE AIR VOLUME M MOTOR WB WET BULB VENTILATION 5ChEDULE (PER A5HRAE G2. 1) Zone EXLSTING RTU- I *2 System Primary 2,800 CFM Average 0.225 Occupant Zone Air 0.8 Primary Air, Fraction to I Secondary Air, I Airflow: Outdoor Air Diversity: Distribution Zone: Fro: tion to Zone: Fraction: Effectiveness: Vps XA D Ez Erg Fr Uncorrected G3 I CFM System 0.043 Min. Outside G7 I CFM Fraction of Supply I Fraction of Supply Air I Fraction of I Air Intake: Ventilation Air Required: Air to Zone from to Zone from Fully Outdoor Air to Efficiency: Outside Zone: Mixed Primary Air: Zone from Outside Zone: Vou Ev Vot 0.24 Fa Fb Fc Room Information Room Room Type People Outdoor Air Area Outdoor Air Breathmg Zone Zone Outdoor Airflow Zone Discharge Discharge Outdoor Zone Ventilation Outside Airflow Airflow Air Fraction Efficiency Rate People Total Rate Area Total (CFM/person) Pz (CFM) (CFM/ft2) (ft2) (CFM) (CFM) (CFM) (CFM) Kp Kp*Pz Re Az Ra*AZ Vbz Voz Vdz Zd Evz BREAK Gerieral-Br-eakRoorn 5 1 5 O.OG IO2 7 12 15 131 0.1 15 1.13 CORRIDOR General -Corridors 0 0 0 O.OG 290 18 18 23 179 0.125 1.1 1 EVAL Office -Office 5 1 5 0.0G G7.3 5 10 13 77 0. 1 G9 1.07 EXERCISE Gym -Weights 20 9 ! 80 O.OG G44 39 2 10 274 7G5 0.355 0.551 AREA I EXEKCSE Gym -Weights 20 8 GO O.OG 569 3G 19G 245 551 0.276 0.9G2 AREA LOBBY Office -Main Entry 5 4 20 O.OG 373 23 43 54 599 0.0902 1 . 15 Lobbies MFN General-Kestroom 0 0 0 0 42.2 0 0 O G7 O 1.24 TEI/COMP Office -Office 5 1 5 O.OG 20 2 7 9 35 0.257 0.383 WOMEN General-Restroorn O O O 0 42.5 O 0 0 G7 0 1.24 DIFFU5ER9 GRILLE, AND REGI5TER 5CHEDULE CALLOUT DESCRIPTION FACE 51ZE (IN) INLET 51ZE (IN) N015E CRITERIA @ MAX CFM MODEL EC2424 EGGCRATE GRILLE 24x24 24x24 25 TITUS 50F RC2424 EGGCRATE GRILLE 24x24 24x24 25 TITUS 5OF 5CPOG SUPPLY CEIUNG PLAQUE DIFFUSER 24x24 GO 25 TITUS OMNI 5CP08 5UPPLY CEIUNG PLAQUE DIFFUSER 24x24 80 25 TITUS OMNI A. AIR DEVICE O.E. DIFFU5ER5, REGISTERS AND GRILLES) COLOR SELECTION SHALL BE MADE BY ARCHITECT. CONTRACTOR SHALL SUBMIT COLORIFINISH CHARTS FOR ARCHITECTURAL REVIEW AND SELECTION. B. THE CONTRACTOR SHALL COORDINATE AIR DEVICE FRAME AND/OR SUSPENSION TYPE WITH THE ARCHITECTURAL REFLECTED CEIUNG PLAN. GENERAL NOTE5 A. EACH 51JFMY DIFflJ5ERilREGISTER, RUNOUT 5HALL BE PROVIDED WITH A VOLUME DAMPER. REFER TO THE DIFFUSER TAKE -OFF DETAIL FOR ADDITIONAL INFORMATION. B. DRAWING5 ARE DIAGRAMMATIC ONLY. FINAL ROUTING OF DUCTWORK AND EQUIPMENT LOCATIONS SHALL BE DETERMINED IN THE FIELD. ADDITIONAL OFF5ET5. ELBOWS. ETC. SHALL BE. PROVIDED AND INSTALLED WITHOUT ADDITIONAL C05T TO THE OWNER. C. HVAC EXISTING TO REMAIN UNLESS NOTED OTHERWISE. DEMOLISH AND REMOVE FROM SITE EXISTING DIFFUSERS AND BRANCH DUCTWORK A550CIATED WITH ROOFTOP UNITS OVER SPAN. PROVIDE NEW AS SHOWN. WHERE EXISTING DIFFUSERS OR BRANCH DUCTWORK ARE OF LIKE KIND AND SIZE TO TH05E SHOWN ON THESE PLANS, THEY MAY BE REUSED. RESTORE REUSED BRANCH DUCTWORK OR DIFFUSERS TO LIKE NEW CONDITION AND BALANCE TO CPMs SHOWN ON THESE PLANS. D. SERVICE AND RESTORE E05TING HVAC EQUIPMENT (ROOFTOP UNITS. FANS, ETC) TO GOOD WORKING ORDER. E. WHERE EXISTING THERM05TAT5 ARE AVAILABLE AND IN GOOD CONDITION. RELOCATE TO LOCATIONS SHOWN. WHERE EXI5TING THERMOSTATS ARE UNAVAILABLE OR IN POOR CONDITION, PROVIDE NEW PROGRAMMABLE THERMOSTATS AT LOCATIONS SHOWN. KEYNOTE5 IQ EXISTING BATHROOM EXHAUST TO REMAIN. BALANCE TO 70 CFM EXHAUST AIR. O CONTRACTOR TO FIELD VERIFY EXISTING LANDLORD PROVIDED ROOFTOP UNIT LOCATED AS SHOWN AND 15 3.5 TONS COOLING CAPACITY. NOTIFY DE51GN TEAM OF ANY DISCREPANCY. BALANCE ROOFTOP UNIT TO 1400 CFM SUPPLY AIR AND 340 CFM OUT5IDE AIR. UNDERCUT DOOR I'. 40 TIE NEW 5UPPLY AIR BRANCH DUCT INTO EXISTING SUPPLY AIR TRUNK DUCT. ® TIE NEW RETURN AIR DUCT INTO EXISTING RETURN AIR TRUNK DUCT. ® 4Y0 DRYER EXHAUST DUCT UP TO ROOF CAP WITH BACKDRAFT DAMPER. WHERE TERMINATION 15 WITHIN I a HORIZONTALLY FROM ANY OUT5IDE AIR INTAKES. IOCATE MINIMUM 3' ABOVE OUT5IDE AIR INTAKES. Q EXHAUST DUCT TO EXTERIOR WALL CAP WITH INSECT SCREEN. 1 N PROFICIENT E N G I N E E RI N G 6991 Peachtree Industrial Blvd Building 700 Peachtree Corners, Georgia 30092 404.330.9798 PROJECT # 118166 I __ wzzo °Z�a _ U � O a wa�� < o~�= Ur z yoy w ~ 4. Is V = 9 ¢ O w ZTO w 3: 0 � o�aN O NWx w =.oz~ '<z¢O O `'plllill1„I,$q, V%CEK* ` No. 0199 # fLOR►Da '��, U CL Q x N co 6� MD QU z z� J w N F­ LL ` LL - w w (� Z °o i � � O Q Q W w w ti = 0*) U) LO It PT� SOLUTIO.S 7V z OLUQ UQM ILL ILL W � o?LL o Xn J J_ inJ O J = M O �Uj NtiN AN 1 FLOOR PLAN - HVAC M-1 1 /8"=1'-011 04-09-2018 DRYER EXHAUST DETAIL NO SCALE PROVIDE FIRESTOPPING AT PENETRATION OF RATED ASSEMBLIES PROVIDE (2) 1 8x 10 MAKEUP AIR GRILLES EQUAL TO TITUS 350ZFL DOOR NOTE: EXTEND DRYER VENT TO U.L. LISTED CAP WITH BACKDRAFT DAMPER. 4" Q DRYER VENT IN WALL DOWN TO DRYER WALL BOX. DRYER WALL BOX FLEXIBLE CONNECTOR 31-01, (0-0" FOR STACKED) I . EXHAUST DUCT VENT PIPE FOR CLOTHES DRYERS SHALL BE SHEET METAL, MINIMUM 2G GAUGE, AND HAVE A SMOOTH INTERIOR FINISH AND SHALL BE MINIMUM OF 4"0. THE ENTIRE EXHAUST SYSTEM SHALL BE SUPPORTED AND SECURED IN PLACE WITH NO PENETRATIONS OF THE DUCTWORK. THE MALE END OF THE DUCT AT OVERLAPPED DUCT JOINTS SHALL EXTEND IN THE DIRECTION OF AIRFLOW. 2. DRYER EXHAUST DUCT SHALL TERMINATE IN WALL AT A DRYER WALL BOX. THE BOX SHALL HAVE A CONNECTION IN THE VERTICAL POSITION FOR FLEXIBLE CONNECTOR TO DRYER COLLAR. 3. CLEAN -OUT OF THE DRYER VENT EXHAUST SYSTEM CAN BE ACCOMPLISHED BY REMOVING THE FLEXIBLE CONNECTOR AND REMOVING ANY EXCESS DRYER LINT. 4. THE ENTIRE DRYER EXHAUST VENT SYSTEM SHALL BE IN ACCORDANCE WITH THE LATEST LOCAL MECHANICAL CODES AND AMENDMENTS. 5. IF LAUNDRY CLOSET DOOR IS LOUVERED, MAKEUP AIR GRILLES MAY BE OMITTED. DRYER VENT WALL BOX DETAIL NO SCALE DRYER VENT DRYERBOX N 425 OR EQL BASEBOARD ,RYER JST DUCT )TES; I NSTALL DRYER VENT BOX PER MANUFACTURER'S RECOMMENDATIONS. DRYER BOX 15 RATED TO BE INSTALLED IN A I -HOUR WALL WHEN INSTALLED IN ACCORDANCE WITH U.L. SYSTEM NO. W-L-71 29. DIFFUSER TAKE -OFF DETAIL NO SCALE ROUND SHEET METAL DUCT DIAMETER AS INDICATEDON PLANS. TRUNK DUCT NOTE: SPIN -IN FITTING WITH SCOOP DAMPER HERE FOR ACCESSIBLE CEILINGS CONNECT FLEX DUCT ENDS TO SHEET METAL DUCT AND DIFFUSER NECK WITH NYLON TIES. INTERIOR LINER AND EXTERIOR INSULATION OF FLEX DUCT TO BE TIED INDIVIDUALLY. INSTALL USING TEN510NING TOOL AS PER MANUFACTURER'S RECOMMENDATIONS. NYLON TIE ON EXTERIOR INSULATION NYLON TIE ON INTERNAL LINER INTERIOR LINER PREIN5ULATED FLEXIBLE DUCTWORK. SEE SPECIFICATIONS. LENGTH SHALL NOT EXCEED 8'-0" PROVIDE SUPPORT PER SMACNA STANDARDS. INSTALL FREE OF KI NK5 SAGS. DAMPER HERE FOR INACCESSIBLE CEILINGS (I.E. HARD CEILINGS) J PROVIDE FACTORY, f PRE -MOLDED INSULATION BLANKET ON DIFFUSER BACKPLATE SUPPLY DIFFUSERV CEILING SEE ARCH. WHERE BRANCH DUCT SIZE DIFFERS FROM SCHEDULED DIFFUSER NECK SIZE, CONTRACTOR SHALL PROVIDE NECESSARY TRANSITION. DUCTWORK DETA I US NO SCALE 5-CLIP JOINT OR ADHESIVE GASKET FITTING 450 LATERAL��' TEE O i O � ROUND - ROUND CONICAL TEE Al RFLOW O �— oL Q M.V.D. RECTANGULAR - ROUND M.V.D. Al RFLOW X I 4— Q --I X2 WHERE: X2 = (I /4)'(X 1), 4" MIN. RECTANGULAR - RECTANGULAR SPECIFICATIONS SHOP DRAWINGS: SUBMIT SHOP DRAWINGS FOR REVIEW. PDF FILES PREFERRED. SHOP DRAWINGS SHALL BE BOUND INTO VOLUMES (FILES), WITH EACH VOLUME (FILE) CONTAINING ONE COPY OF ALL SHOP DRAWINGS. ALL SHOP DRAWINGS SHALL BE SUBMITTED SIMULTANEOUSLY; NO SHOP DRAWINGS WILL BE CHECKED UNTIL ALL HAVE BEEN SUBMITTED. SUBMITTALS SHALL BE SUPPORTED BY DESCRIPTIVE MATERIAL, SUCH AS CATALOG CUTS, DIAGRAMS, PERFORMANCE CURVES AND CHARTS PUBLISHED BY THE MANUFACTURER, TO SHOW CONFORMANCE TO SPECIFICATION' AND DRAWING REQUIREMENTS; MODEL NUMBERS ALONE WILL NOT BE ACCEPTABLE. ALL LITERATURE SHALL CLEARLY INDICATE THE SPECIFIED MODEL NUMBER, DIMENSIONS, ARRANGEMENT, RATING AND CHARACTERISTICS OF THE PROPOSED EQUIPMENT. CAPACITIES AND RATINGS SHALL BE BASED ON CONDITIONS INDICATED OR 5PECIFIED HEREIN. ANY DEVIATIONS FROM SPECIFIED EQUIPMENT (PARTICULARLY THOSE WHICH REQUIRE COORDINATION WITH OTHER TRADES) SHALL BE CLEARLY NOTED IN A CONCISE LIST ON A SEPARATE SHEET. TEST AND BALANCE: THE CONTRACTOR SHALL RETAIN THE SERVICES OF AN INDEPENDENT TEST AND BALANCE AGENCY THAT IS INDEPENDENT OF ANY CONTRACTOR RA R R SUB CONT CTO OMANUFACTURER TO PERFORM THE TESTING AND BALANCING AND PREPARE REPORTS TO THE GENERAL CONTRACTOR. THE INDEPENDENT TEST AND BALANCE AGENCY SHALL HAVE A CERTIFIED MEMBER OF THE NATIONAL ENVIRONMENTAL BALANCING BUREAU (NEBB). TEST AND BALANCE SHALL ALSO PROVIDE QUOTE TO PERFORM BALANCING FOR COMFORT SIX MONTHS AFTER THE SPACE IS OCCUPIED. P-TAB.COM OR EQUIVALENT. GUARANTEE THAT EACH PIECE OF APPARATUS SHALL BE OF THE CUSTOMARY STANDARD AND QUALITY FURNISHED BY THE DESIGNED MANUFACTURER FOR THAT CATALOG NUMBER. GUARANTEE THAT THE AIR SYSTEMS SHALL OPERATE WITHOUT AERODYNAMIC NOISE GENERATED FROM THE FAULTY INSTALLATION OF DUCT WORK OR ANY COMPONENT OF THE AIR DISTRIBUTION SYSTEM. GUARANTEE THAT ALL SYSTEMS AND COMPONENTS SHALL BE PROVIDED WITH A ONE YEAR WARRANTY FROM THE TIME OF DATE OF SUBSTANTIAL COMPLETION. THE WARRANTY SHALL COVER ALL MATERIALS AND WORKMANSHIP DURING THIS WARRANTY PERIOD, ALL DEFECTS IN MATERIALS AND WORKMANSHIP SHALL BE CORRECTED BY REPAIR OR REPLACEMENT WITHOUT INCURRING ADDITION'S TO THE CONTRACT, GENERAL NOTES: REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT LOCATION OF ALL CEILING MOUNTED EQUIPMENT. ALL DUCT DIMENSIONS INDICATED IN THESE DOCUMENTS ARE INSIDE -CLEAR DIMENSIONS. PORTIONS OF DUCTWORK OR PIPING VISIBLE THROUGH GRILLES AND REGISTERS IN FINISHED AREAS SHALL BE PAINTED FLAT BLACK. PAINT BLACK BEHIND ALL GRILLES. ALL WIRING IN THE CEILING PLENUM SHALL BE PLENUM RATED CABLE. MOUNTING FRAME OF CEILING MOUNTED AIR DISTRIBUTION DEVICES SHALL BE COMPATIBLE WITH CEILING TYPE. REFER TO ARCHITECTURAL DRAWINGS FOR CEILING TYPE. ALL FIRE SEPARATIONS MUST BE PROTECTED WHEN APPLICABLE. PROVIDE NEW FILTERS (MERV 7 OR BETTER PER OWNER) FOR ALL APPLICABLE HVAC EQUIPMENT AT THE END OF CONSTRUCTION. ALL MATERIAL IN PLENUM MUST MEET FIRE AND SMOKE SPREAD AS REQUIRED BY NFPA 90A. ALL ROOF PENETRATIONS TO BE 1 2" APART AND AT LEAST 1 2" AWAY FROM CURBS, WALLS, AND DRAIN SUMPS TO PROVIDE ROOFING CONTRACTOR WITH SUFFICIENT ACCESS FOR FLASHING EACH ROOF PENETRATION. SUBSTITUTIONS MUST BE APPROVED IN WRITING BY ARCHITECT PRIOR TO BID SUBMISSION. CONTRACTOR SHALL REVIEW ALL CONTRACT DOCUMENTS AND SHALL BE FAMILIAR WITH THE SCOPE AND REQUIREMENTS OF THIS PROJECT. ANY DISCREPANCIES OR LACK. OF CLARITY IN THE DOCUMENTS SHALL BE IDENTIFIED TO THE ARCHITECT OR ENGINEER PRIOR TO THE 5UBMI55ION OF PRICING BIDS. WITH A SUBMITTED BID, CONTRACTOR 15 ACCEPTING THESE DOCUMENTS AS SUFFICIENT DEFINITION OF THE SCOPE OF WORK, AND ANY ADDITIONAL COSTS BASED ON UNCLAKITY OF CONTRACT DOCUMENTS WILL NOT BE CONSIDERED. THE CONTRACTOR SHALL REFERENCE THE FULL SET OF CONSTRUCTION DOCUMENTS DURING PRICING AND CONSTRUCTION FOR COORDINATION BETWEEN DISCIPLINES RELATIVE TO THE MECHANICAL SCOPE. DUCTWORK AND ACCESSORIES: INDUSTRY STANDARDS: COMPLY WITH 5MACNA (SHEET METAL AND AIR CONDITIONING CONTRACTORS' NATIONAL ASSOCIATION) HVAC DUCT CONSTRUCTION STANDARDS, RECOMMENDATIONS FOR FABRICATION, GAUGES, CONSTRUCTION AND DETAILS, AND INSTALLATION PROCEDURES, EXCEPT AS OTHERWISE INDICATED. COMPLY WITH ASHRAE (AMERICAN SOCIETY OF HEATING, REFRIGERATING AND AIR CONDITIONING ENGINEERS) FUNDAMENTALS HANDBOOK RECOMMENDATIONS, EXCEPT AS OTHERWISE INDICATED, DUCTWORK METAL AND GAUGES: EXCEPT AS OTHERWISE INDICATED, FABRICATE DUCTWORK FROM GALVANIZED SHEET STEEL COMPLYING WITH ASTM A527, LOCKFOKMING QUALITY, WITH ASTM A525 GOO ZINC COATING, MILL PH05PHATIZED, GAUGES TO COMPLY WITH SMACNA STANDARDS. DUCT SEALANT: NON -HARDENING, NON -MIGRATING MASTIC OR LIQUID ELASTIC SEALANT (TYPE APPLICABLE FOR THE FABRICATION/INSTALLATION DETAIL) AS COMPOUNDED AND RECOMMENDED BY THE MANUFACTURER SPECIFICALLY FOR SEALING JOINTS AND SEAMS IN DUCTWORK DUCTWORK SUPPORT MATERIALS: EXCEPT AS OTHERWISE INDICATED, PROVIDE UPPER ATTACHMENT, HANGERS OF GALVANIZED STEEL STRAPS, OR STEEL RODS AND LOWER ATTACHMENT FOR SUPPORT OF DUCTWORK. HANGING/SUPPORT 5Y5TEM5 SHALL BE IN ACCORDANCE WITH SMACNA REQUIREMENTS. EXPOSED DUCTWORK SHALL BE DOUBLE -WALL SPIRAL PIPE WITH PAINT GRIP UNLESS OTHERWISE NOTED OR SUBSTITUTION APPROVED BY OWNER. VOLUNTARY ALTERNATE EXPOSED DUCTWORK SHALL BE SINGLE -WALL SPIRAL PIPE UNLESS OTHERWISE NOTED OR 5UB5TITUTION APPROVED BY OWNER. ALL EXPOSED DUCTWORK SHALL BE LINED IN LIEU OF WRAPPED. DUCT LINER THERMAL RESISTANCE SHALL MEET THE MINIMUM VALUES SPECIFIED IN PARAGRAPH 'DUCT INSULATION' BELOW. DUCT INSULATION: K-5 SUPPLY, OUTSIDE AND RETURN AIR DUCT INSULATION IN UNCONDITIONED SPACES K-8 SUPPLY AND RETURN AIR DUCT INSULATION OUTSIDE THE BUILDING K-8 INSULATION BETWEEN DUCTS AND THE BUILDING EXTERIOR WHEN DUCTS ARE PART OF A BUILDING ASSEMBLY SPECIFICATIONS DIFFUSERS, GRILLES, 4 REGISTERS: EGGCRATE GRILLE: RETURN GRILLES SHALL BE TITUS MODEL 50F FOR THE SIZES AND MOUNTING TYPES AS SHOWN ON THE PLANS AND OUTLET SCHEDULE. RETURN GRILLES MUST PROVIDE A FREE AREA OF AT LEAST 90%. OUTER BORDERS SHALL BE CONSTRUCTED OF HEAVY EXTRUDED ALUMINUM WITH A THICKNESS OF O.040-0.050 INCH AND SHALL HAVE COUNTERSUNK SCREW HOLES FOR A NEAT APPEARANCE. BORDER WIDTH SHALL BE I %4 INCHES ON ALL SIDES AND SHALL BE INTERLOCKED AT THE FOUR CORNERS AND MECHANICALLY STAKED TO FORM A RIGID FRAME. CHOICE OF THREE SIZES OF ALUMINUM GRID: V2 X /2 X %2 INCH, �/2 X %2 X I INCH, OR I X I X I INCH SHALL BE AVAILABLE. OPTIONAL OPPOSED -BLADE VOLUME DAMPER SHALL BE CONSTRUCTED OF HEAVY GAUGE STEEL OR ALUMINUM. DAMPER MUST BE OPERABLE FROM THE FACE OF THE GRILLE. PLAQUE DIFFUSERS: ARCHITECTURAL SQUARE PANEL CEILING DIFFUSERS SHALL BE OF THE SIZES AND MOUNTING TYPES SHOWN ON THE PLANS AND OUTLET SCHEDULE. THE FACE PANEL IS REMOVABLE BY OF F MEANS O OUR HANGER BRACKETS. THE EXPOSED SURFACE O THE FACE PANEL SMALL BE SMOOTH, FLAT, AND FREE OF VISIBLE FASTENERS. THE BACK OF THE FACE PANEL SHALL HAVE AN AERODYNAMICALLY SHAPED, ROLLED EDGE TO ENSURE A TIGHT HORIZONTAL DISCHARGE PATTERN. CEILING DIFFUSERS WITH A 24 X 24-INCH FULL FACE SHALL HAVE NO LESS THAN AN 18 X 18-INCH FACE PANEL SIZE. CEILING DIFFUSERS WITH A 12 X 12-INCH FULL FACE SHALL HAVE NO LESS THAN A 9 X 9-INCH FACE PANEL SIZE. THE 13ACKPAN SHALL BE ONE PIECE PRECISION DIE -STAMPED AND SHALL INCLUDE AN INTEGRALLY DRAWN INLET. THE DIFFUSER NECK SHALL HAVE A MINIMUM OF 1 �/4-INCH DEPTH AVAILABLE FOR DUCT CONNECTION, THE FINISH SHALL BE #2G WHITE. THE FINISH SHALL BE AN ANODIC ACRYLIC PAINT, BAKED AT 3 1 5°F FOR 30 MINUTES. THE PENCIL HARDNESS MUST BE HB TO H. THE PAINT MUST PASS A 100-HOUR A5TM B 1 17 CORROSIVE ENVIRONMENTS SALT _`)PRAY TEST WITHOUT CREEPAGE, BLISTERING OR DETERIORATION OF FILM. THE PAINT MUST PASS A 250-HOUR ASTM D870 WATER IMMERSION TEST. THE PAINT MUST ALSO PASS THE ASTM D2794 REVERSE IMPACT CRACKING TEST WITH A 50-INCH POUND FORCE APPLIED. OPTIONAL ROUND DAMPER SHALL BE CONSTRUCTED OF HEAVY GAUGE STEEL. DAMPER MUST BE OPERABLE FROM THE FACE OF THE DIFFUSER. OPTIONAL DIRECTIONAL BLOW CLIPS SHALL BE AVAILABLE TO RESTRICT THE DISCHARGE AIR IN CERTAIN DIRECTIONS. OPTIONAL MOLDED INSULATION BLANKET SHALL BE AVAILABLE. THE INSULATION WILL BE K-G, FOIL -BACKED, AND PROVIDE AN ADDITIONAL I -INCH GAP AROUND THE NECK TO INSTALL INSULATED FLEX DUCT. THE MANUFACTURER SHALL PROVIDE PUBLISHED PERFORMANCE DATA FOR THE SQUARE PANEL DIFFUSER. THE DIFFUSER SHALL BE TESTED IN ACCORDANCE WITH AN5I/A5HRAE STANDARD 70- 199 1 . CEILING FAN: CEILING MOUNTED EXHAUST FANS SHALL BE OF THE CENTRIFUGAL DIRECT DRIVE TYPE. THE FAN HOUSING SHALL BE CONSTRUCTED OF STEEL. THE PLASTIC DUCT COLL\K SHALL BE A TAPERED SLEEVE FOR EASE OF CONNECTION TO 3 IN AND 4 IN ROUND DUCTWORK AND SHALL INCLUDE A BACKDKAFT DAMPER. THE GRILLE SHALL BE CONSTRUCTED OF NON -YELLOWING HIGH STRENGTH POLYMER AND ATTACHED TO THE HOUSING WITH TORSION SPRINGS. THE WHEELS SHALL BE CONSTRUCTED OF HIGH STRENGTH POLYMER. THE ACCESS FOR WIRING SHALL BE EXTERNAL. THE MOTOR DISCONNECT SHALL BE INTERNAL AND OF THE PLUG IN TYPE. ALL FANS SHALL BEAR THE AMCA CERTIFIED RATINGS SEALS FOR SOUND AND AIR PERFORMANCE AND SHALL BE U.L. LISTED. W -h 2 9 o U .N 0" PROFICIENT �O Q a �=pz z ¢m� E N G I N E E R I N G¢ 6991 Peachtree Industrial Blvd Building 700 ¢ � 0 5 Peachtree Corners, Georgia 30092 = "� D. w W 3g°'=- 404.330.9798 (D g W i a PROJECT # 118166 o m _ LU u �ozLL cD GZ 40 9 ' * : No. T0,199 FLORIDN .a� ,,. G� "411nu11111u10a�. x 0 w N It 02 (y) p QU D ~ Z Q9 F_ Q � J W N LL 04 LL Q W C4 Lll C Z (8)(10. i It < z .t w O� Q Uw D LL LL L.L > _ h U) L0 It IQ OT-, M-L'U°E IONS y Z O 0 'it_ U Q co LL ILL Cl) °w _jm-j O J = Cn 0-oa N tiN M-2 04-09-2018 FT LUMINAIRE SCHEDULE CALLOUT SYMBOL LAMP DESCRIPTION MODEL VOLTS C (1),7.GW LED G" SUSPENDED LED CYLINDER LITHONIA LIGHTING - "LDNGCYL40/05 LOGAR LID MVOLT 120V 1 P 2W EZ I PM DWHG CYS`*" D 1 (1) 1 2.8W LED G" RECESSED DOWNLIGHT LITHONIA LIGHTING - LDNG 40/ 10 LOGAR LSS MVOLT 120V IF 2W O EZ 10 D2 (1) 1 2.8W LED G" RECESSED DOWNLIGHT LITHONIA LIGHTING - LDNG 40/ 1 0 LOGAR LSS MVOLT 120V IF 2W 0 EZI L 0 (1) 2 1 W LED 2' LED STRIP LITHONIA LIGHTING - WL2 22L EZ I LP840 120V I P 2W P 1 (1) 52W T8 LED LINEAR PENDANT PEERLESS LIGHTING - 7CRM7L QST LLP 4 MSL4 80CKI 120V 1 P 2W 40K 11 30OLMF DARK-ZT *VOLTAGE'S SCT `MOUNTING* `SUSPENSION* C2 10 (QUICK SHIP) T Ip (2) 1 .5W LED EMERGENCY LIGHTING UNIT LITHONIA - EU2 LED M 12 120V 1 P 2W XC I 71N LED WET LISTED REMOTE SINGLE LAMP HEAD LITHONIA - EC R LED Oh MG 120V IF 2W XK (1) INCLUDED REMOTE LAMP HEAD LITHONIA ELA LED WP M 12 120V I P 2W FOR ORDERING INFORMATION, CONTACT TAYLOR SCHERER - SMART LIGHTING SOLUTIONS FOR PRICING 770-545-899 I GENERAL SCHEDULE CALLOUT SYMBOL VOLTS KVA CIRCUIT WIRE CALLOUT DISCONNECT DESCRIPTION EF- I 120V I P 2W 0.1 A-29 I /2"C, 1# 1 2,# 1 2N,# 12G CONTROLLED BY THERMOSTAT EF-2 120V I: P 2W 0.1 A-5 1 /2"C, I # 1 2,# 12N,# 12G SWITCHED WITH MICROWAVE WH- I �'^�Q' 120V I P 2W j 1.5 A-24 1 /2"C, I# 1 2,# 1 2N,# 12G 3OA/ I P/NEMA I KEYNOTES C EXISTING ELECTRICAL PANEL TO BE REUSED. 2 COORDINATE EXACT LOCATION' WITH THE TENANT AND MILLWORK OF FURNITURE, AND PROVIDE Q R K R R QUAD POWER AND VOICE/DATA OUTLETS. RECEPTACLE LOCATED ABOVE COUNTER. ROUTE (1) 2"C WITH PULL STRING TO TELEPHONE UTILITY DEMARCATION POINT. POWER AND LV OUTLET FOR TV. EXACT MOUNTING HEIGHT TO BE CONIFIKMED WITH THE TENANT PRIOR TO ROUGH -IN. BREAK ROOM EXHAUST FAN IN CEILING TO BE CONTROLLED WITH SWITCH AT THE COUNTER. THE SWITCH SHALL BREAK CIRCUIT FOR BOTH THE MICROWAVE AND THE EXHAUST FAN. OUTLET FOR MICROWAVE TO BE LOCATED ABOVE MICROWAVE SHELF. COORDINATE MOUNTING HEIGHT AND EXACT LOCATION WITH TENANT PRIOR TO ROUGH -IN. Q EXHAUST FAN IN CEILING TO BE CONTROLLED BY THERMOSTAT. SEE HVAC DRAWINGS FOR ADDITIONAL INFORMATION. PROVIDE 30A/I P/NEMA I DISCONNECT SWITCH. WATER HEATER MOUNTED ON PLATFORM, COORDINATE WITH PLUMBING CONTRACTOR FOR ADDITIONAL INFORMATION.. O9 COORDINATE NEMA CONFIGURATION AND MOUNTING HEIGHT FOR THE WASHEF)DRYER RECEPTACLE WITH EQUIPMENT VENDOR PRIOR TO ROUGH -IN. CONFIRM POWER REQUIREMENTS WITH EQUIPMENT VENDOR. (ID COORDINATE EXACT LOCATION WITH THE TENANT AND MILLWORK OF FURNITURE, AND PROVIDE QUAD POWER AND VOICE/DATA OUTLETS MOUNTED TO THE SIDE OF THE SUPPORT/APRON, INSTALLED SIDEWAYS AND TIGHT TO THE TOP. I ! TYPE C FIXTURES TO BE SUSPENDED FROM CEILING AT 7-0" AFF. TYPICAL. 12 EXISTING BATHROOM EXHAUST FAN TO REMAIN. CIRCUIT AND SWITCH WITH BATHROOM LIGHTS. CD INSTALL XK FIXTURE IF NO EMERGENCY RATED OUTSIDE LIGHTS ARE EXISTING. 14 EXISTING PANEL TO REMAIN FOR FUTURE USE. GENERAL NOTES EXPOSED CONDUITS SHALL BE ROUTED PERPENDICULAR OR PARALLEL TO EXTERIOR WALLS. MC CABLE IS NOT ALLOWED IN EXPOSED CEILING EXCEPT FOR THE FINAL CONNECTIONS TO EQUIPMENT WITH MAXIMUM OF I8". WHERE LOW VOLTAGE DEVICES ARE SHOWN, PROVIDE EMPTY CONDUITS WITH PULL STRINGS TO ABOVE CEILING OR TO STRUCTURAL CEILING FOR LOW VOLTAGE OUTLETS AND WIRING BY LOW VOLTAGE CONTRACTOR. JUNCTION BOXES SHALL BE MOUNTED AT SAME HEIGHT AS THE POWER OUTLET. REMOVE EXISTING OUTLETS. IF EXISTING OUTLET 15 WITHIN 1 2" OF THE OUTLETS SHOWN ON PLAN THEN IT MAY BE REUSED. IS OUTLET IS SHOWN WITH A DEDICATED CIRCUIT, OUTLET MAY BE REUSED, BUT SHALL BE PROVIDED WITH NEW CIRCUIT. COORDINATE IN FIELD FOKTHE LOCATION OF EXISTING ELECTRICAL PANELS REFERENCED ON THIS SET OF DRAWINGS. VERIFY EXISTING CIRCUIT BREAKERS THAT PREVIOUSLY SERVED THE SPACE IN SCOPE AND REUSE. PROVIDE NEW BREAKERS AS NEEDED. NEW BREAKERS SHALL BE COORDINATED WITH EXISTING DISTRIBUTION' SYSTEM. EXISTING HVAC EQUIPMENT AND ROOFTOP MAINTENANCE RECEPTACLES REMAINING TO BE REUSED. MAINTAIN CIRCUITING. REFER TO ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT LOCATIONS OF ALL CEILING MOUNTED DEVICES. PROVIDE UNSWITCHED HOT LEG OF CIRCUIT TO EMERGENCY LIGHTING AND EXIT SIGNS. A- 10 r FUTURE A 2 I ,23 ! /2"C,2# 1:0,# I OG W f/ � A-7 f 7-8" AFF A R A-28 1 A-30 F-AM01 A-2 2 T-8�FF 4 A-2 WP A-2G 7-8" AFF 0 PROFICIENT E N G I N E E R I IN G 6991 Peachtree Industrial Blvd Building 700 Peachtree Comers, Georgia 30092 404.330.9798 PROJECT # 118166 A-G: A- I G �Z�Zo � OwOa 'sI, _ 0 LU Zto, V' �aa3ir O n� a3= LU =rO0 F-¢Zz¢O O . 67193 *� AAR= ATE �� FLOR1Qa•' AL E . N It O M O QU Z Z ry CD AWL N Q W `9 W /LyO� ' W Z t 7 w wrr^. V U� � W W U_ _ LL Uj fn c� PT S LU"IG S y Z 'It 0 W w M V Q M �ILL >Q IL W _I O LL JJmJ O= _ TZ M W W N ti N E-1 AD FLOOR PLAN -LIGHTING 1' f8"=1'-0„ 1 FLOOR PLAN - POWER E-1 1�811=1'-011 SPECIFICATIONS GENERAL CONTRACTOR SHALL REFER TO ALL RELATED DOCUMENTS, ARCHITECTURAL, STRUCTURAL, CIVIL AND MEP DRAWINGS, AND FULLY UNDERSTAND THE SCOPE OF WORK AND CONDITION OF CONSTRUCTION. THE WORK UNDER THIS SPECIFICATIONS AND DRAWINGS SHALL INCLUDE ALL LABOR. ALL INSTALLATION OF DEVICES AND CONNECTION OF CONDUCTORS SHALL BE PERFORMED BY LICENSED AND SKILLED ELECTRICIAN OR JOURNEYMAN. ALL WORK SHALL BE COMPLETED TO THE SATISFACTION OF THE OWNER. IF ANY PORTION OF THE WORK IS FOUND UNSATISFACTORY BY THE OWNER, IT SHALL BE REMOVED AND REINSTALLED WITHOUT DELAY AT NO COST TO THE OWNER. THE WORK INCLUDES, BUT NOT LIMITED TO: THE COMPLETE ELECTRICAL DISTRIBUTION SYSTEM. ROUGH -IN AND FINAL CONNECTIONS TO ALL DEVICES REQUIRING ELECTRICAL POWER, INCLUDING OWNER PROVIDED EQUIPMENT. LIGHTING CONROL LIGHTING FIXTURES EACH CONTRACTOR SHALL OBTAIN ALL PERMITS AND INSPECTIONS REQUIRED BY THE REGULATORY AUTHORITIES. ALL FEES RELATED TO OBTAINING PERMITS AND INSPECTION SHALL BE PAID FOR BY EACH CONTRACTOR IN HIS TRADE. ALL MATERIALS AND WORKMANSHIP SHALL COMPLY WITH LOCAL, COUNTY, STATE, AND NATIONAL ELECTRICAL CODE 201 1, SPECIFICATIONS, UTILITY COMPANY REQUIREMENTS AND ALL INDUSTRY STANDARDS. ANY DIFFERENCES IN ABOVE MENTIONED REQUIREMENTS, THE MOST STERN SHALL OVERRULE ALL OTHERS. IN ADDITION TO ABOVE MENTIONED CODES AND SPECIFICATIONS, THE FOLLOWING INDUSTRY STANDARDS SHALL BE COMPLIED If THEY ARE MORE STRINGENT. IEEE I ES IECC 2015 ASHRAE 90.1 N FPA NEMA UL ADA THE MANUFACTURER'S PUBLISHED DIRECTIONS SHALL BE FOLLOWED IN THE DELIVERY, STORAGE, PROTECTION, INSTALLATION AND WIRING OF ALL EQUIPMENT AND MATERIAL. THE DRAWINGS SHOW DIAGRAMMATICALLY THE LOCATIONS OF THE VARIOUS LINES, CONDUITS, FIXTUKE5, AND EQUIPMENT AND THE METHOD Of CONNECTING AND CONTROLLING THEM. IT IS NOT INTENDED TO SHOW EVERY CONNECTION IN DETAIL AND ALL FITTINGS REQUIRED FORA COMPLETE SYSTEM. THE SYSTEMS SHALL INCLUDE BUT ARE NOT LIMITED TO THE ITEMS SHOWN ON THE DRAWINGS. EXACT LOCATIONS OF THESE ITEMS SHALL BE DETERMINED BY REFERENCE TO THE GENERAL PLANS AND MEASUREMENTS AT THE BUILDING AND IN COOPERATION WITH THE OTHER SUBCONTRACTORS, AND IN ALL CASES, SHALL BE SUBJECT TO THE APPROVAL OF THE OWNER. THE OWNER RESERVES THE RIGHT TO MAKE ANY REASONABLE CHANGE IN THE LOCATION OF ANY PART OF THIS WORK WITHOUT ADDITIONAL COST TO THE OWNER, CONTRACTOR SHALL SEEK APPROVAL FROM THE OWNER FOR ANY CHANGES TO THE SPECIFICATIONS OR CONTRACT DOCUMENTS. ANY EXCEPTIONS, INCONSISTENCIES AND CONFLICTS IN CONTRACT DOCUMENTS, SPECIFICATIONS AND CONTRACT DOCUMENTS BY OTHER TRADE SHALL BE BROUGHT TO ATTENTION TO THE OWNER PRIOR TO BID. CONTRACTOR SHALL COORDINATE AND VERIFY THE WORK WITH EXISTING CONDITIONS AND THE WORK OF OTHER TRADE PRIOR TO ANY FABRICATIONS OR INSTALLATION. IF THE LAYOUT OF THE DEVICES ON DRAWINGS ARE IMPRACTICAL TO THE CONDITION IN FIELD, CONTRACTOR SHALL NOTIFY THE OWNER IMMEDIATELY PRIOR TO ANY FABRICATION OR INSTALL\TION. ELECTRICAL DEVICES ARE INDICATED ON DRAWINGS AT APPROXIMATE LOCATIONS. THE OWNER RESERVE THE RIGHT TO MAKE REASONABLE CHANGES IN LOCATIONS WITHOUT ADDITIONAL COSTS. THE LINES INDICATING BRANCH CIRCUITS DO NOT REPRESENT THE ROUTING OF ELECTRICAL CONDUITS. THEY INDICATE THE LAYOUT AND CONTROL OF CIRCUITS. PRODUCTS AND WORK MATERIALS FURNISHED SHALL BE NEW AND BY STANDARD MANUFACTURERS AND MUST CONFORM TO THE NATIONAL BOARD OF FIRE UNDERWRITER'S REQUIREMENTS AND BEAR THE UNDERWRITER'S LABORATORIES' SEAL OF APPROVAL. LISTED MANUFACTURERS, MODELS, OR CATALOGUE NUMBERS IN PART OR ALL SHALL ENTAIL TO INCLUDE THE PUBLISHED MANUFACTURER'S DESCRIPTION AND SPECIFICATION. CONTRACTOR SHALL NOT INTERPRET THAT THE LISTED MANUFACTURERS IN 5PECIPICATION5 OR DRAWINGS TO EXCLUDE ALL OTHER MANUFACTURERS CONTRACTOR SHALL MAKE CERTAIN THAT ALL EQUIPMENT FIT IN THE SPACE DESIGNATED AND DESIGNED FOR THE SURROUNDINGS IT OCCUPIES. COMPLETE CATALOGUE ILLUSTRATION AND DESCRIPTIONS OF ALL EQUIPMENT SHALL BE SUBMITTED TO THE OWNER PRIOR TO ORDERING ANY EQUIPMENT. ALL HORIZONTAL RUNS OF CONDUITS SHALL BE SUPPORTED BY MEANS OF APPROVED HANGER FROM THE STRUCTURAL CEILING. COORDINATE THE WORK UNDER THI5 SECTION WITH ALL OTHER TRADES. CONDUITS AND RACEWAYS. - MANUFACTURERS: SQUARE D, B-LINE, ALLIED TUBE * CONDUIT, HOFF MAN, CAKLON ELECTRICAL, WIKEMOLD, OUTDOORS EXPOSED: RIGID STEEL. OUTDOORS CONCEALED ABOVE GROUND: RIGID STEEL. OUTDOORS UNDERGROUND: TYPE EPC-40-PVC OUTDOORS CONNECTION TO VIBRATING EQUIPMENT (INCLUDING TRANSFORMERS AND MOTOR DRIVEN EQUIPMENT): LFMC. BOXES AND ENCLOSURES ABOVE GROUND: NEMA 3K UNLESS NOTED OTHERWISE ON PLANS. INDOORS EXPOSED NOT SUBJECT TO PHYSICAL DAMAGE: EMT. INDOORS EXPOSED NOT SUBJECT TO SEVERE PHYSICAL DAMAGE: EMT. INDOORS EXPOSED SUBJECT TO SEVERE PHYSICAL DAMAGE: RIGID STEEL CONDUIT. INDOORS CONCEALED IN CEILINGS AND INTERIOR WALLS AND PARTITIONS: EMT. INDOORS CONNECTION TO VIBRATING EQUIPMENT: FMC, EXCEPT USE LFMC IN DAMP OR WET LOCATIONS. INDOORS DAMP OR WET LOCATIONS: IMC. INDOORS LOW -VOLTAGE CABLES: EMT. SPECIFICATIONS r-nrini lr'Tnp5• COPPER CONDUCTORS # 10 AND SMALLER: LABELED PER UL 83, TYPE THHN/THWN, SOLID COPPER GOO VOLT INSULATION UNIFORM COLOR CODED JACKET WITH JACKET DATA. METAL CLAD (TYPE MC) CABLE WHERE INSTALLED IN ACCORDANCE WITH NEC ARTICLE 334. COPPER CONDUCTORS #8 OR LARGER: LABELED PER UL 83, TYPE THHN,FHWN, STRANDED COPPER, GOOVOLT INSULATION, UNIFORM COLOR CODED JACKET WITH JACKET DATA. ACCEPTABLE MANUFACTURERS OF CONDUCTORS: PI RELLI E 5OUTHWI KE AETNA REPUBLIC AFC ENCORE WIRE KEKITE CONTRACTOR MAY USE ALUMINUM CONDUCTORS FOR #4 AWG OR LARGER IN THE PLACE OF COPPER CONDUCTORS. CONTRACTOR SHALL REFER TO NEC TABLE 3 1 0- I G FOR EQUIVALENT AMPACITY AND SHALL COMPENSATE FOR VOLTAGE DROP. MOLDED CASE CIRCUIT BREAKER: INCLUDE SCHEDULE OF ALL FUSES, RATINGS, TIME COORDINATION DATA, MANUFACTURER'S STANDARD DATA AND TIME -CURRENT CURVES. ALL DATA SHALL BE BASED ON TEST CF STANDARD PRODUCTS. APPROVED MANUFACTURERS: GENERAL ELECTRIC CUTLER HAMMER SQUARE D SIEMENS THERMAL -MAGNETIC BOLT -IN TYPE CIRCUIT BREAKERS WITH QUICK -MAKE, QUICK -BREAK CONTACTS; TRIP -FREE OPERATION WITH OVER -THE -CENTER TOGGLE HANDLE OR NON -REMOVABLE MONOLITHIC TIE -HANDLE. MULTI -POLE BREAKERS SHALL HAVE INTERNAL COMMON TRIP AND COMMON RESET WITH A SINGLE TOGGLE HANDLE OR NON -REMOVABLE MONOLITHIC TIE -HANDLE. TRIP RATINGS SHALL BE MOLDED ON THE HANDLE OR FACE OF BREAKER. BREAKER TERMINALS SHALL BE RATED TO ACCOMMODATE A MINIMUM OF 75 DEGREE C CONDUCTORS. BREAKER SHALL BE RATED FOR MOUNTING AND OPERATION IN ANY POSITION; SHALL ACCOMMODATE AND MATCH THE TYPE OF TERMINATIONS REQUIRED. SINGLE POLE BREAKERS RATED 15 AND 20 AMPERES SHALL BE UL LABELED AS "SWITCHING BREAKERS" AT THE APPLIED CIRCUIT VOLTAGE. MULTI -POLE BREAKERS RATED 100 AMPERES AND LARGER SHALL BE MOLDED CASE THERMAL -MAGNETIC BOLT -IN TYPE BREAKER WITH ADJUSTABLE INSTANTANEOUS TRIP. LIGHTING FIXTURE SUBMITTAL: SCHEDULE BY TYPE DESIGNATION ALL LIGHTING FIXTURES, EACH COMPLETE WITH DATA SHEET WITH COMPLETE PHYSICAL, ELECTRICAL AND LIGHTING CHARACTERISTICS, LAMP TYPE AND LAMP DATA. REFER TO THE "LIGHTING FIXTURE SCHEDULE" \IN THE DRAWINGS FOR. INDIVIDUAL FIXTURE DESCRIPTIONS AND MANUFACTURER TYPES. PROVIDE LAMPS FOR EACH FIXTURE OF QUANTITY, TYPE AND COLOR AS LISTED IN LIGHTING FIXTURE SCHEDULE. GE, SYLVANIA OR PHILIPS ARE ACCEPTABLE. EACH LIGHTING FIXTURE SHALL BE UL LABELED FOR PROPER OPERATION IN THE TYPE OF CEILING CONSTRUCTION AND FOR THE MOUNTING ARRANGEMENT ON/IN WHICH IT IS INSTALLED. FIELD VERIFY ACTUAL CEILING SLOPE FOR FIXTURES INSTALLED IN SAME AND ACTUAL FIELD DIMENSIONS AND ANGLES OF CONSTRUCTION FOR ANY FIXTURE CONFORMING THE SHAPE AND LENGTH OF SAME, FOR COORDINATION OF FIXTURE CONSTRUCTION. ELECTRICAL LEGEND SYMBOLS DESCRIPTION MOUNTING DUPLEX RECEPTACLE, 1 20V, 20A, NEMA 5-20R 1 8" APP DUPLEX RECEPTACLE, 1 20V, 20A, NEMA 5-20K 42" AFF OR G" ABOVE �' COUNTER TOP QUADRAPLEX RECEPTACLE, 1 20V, 20A, NEMA 1 8" AFF 5-20K (1 JUNCTION BOX FLUSH IN WALL WITH COVER. SIZE 1 8" AFF PER NEC. Q JUNCTION BOX PLUSH IN CEILING WITH COVER. IN CEILING SIZE PER NEC. TV OUTLET G'-O" APF $ /$3 /$°%$os I POLE SWITCH / DIMMER SWITCH / 42" AFF OCCUPA CIY SENSORY DISCONNECT SWITCH. SUBSCRIPT: AMP / # OF AS INDICATED ON POLES / ENCLOSURE DWG ELECTRICAL PANELBOARD. REFER TO SURFACE MOUNTED PANELBOAKD SCHEDULE. ON WALL _ EQUIPMENT AS NOTED ON DRAWING. SURFACE MOUNTED ON WALL �V MOTOR HOME RUN WITH WIRE TICKS. XX - PANEL XX-# DESIGNATION, # - CIRCUIT DESIGNATION. WIRE TICKS I) NEUTKALI HOT 111 * GROUND - ( , (3) (1) Q / / v DATA / VOICE / COMBINATION OUTLET 1 8" AFF ELECTRICAL GENERAL NOTES FIXTURE TYPE INDICATED BY UPPER CASE CHARACTERS, SWITCHING AND GROUPING DESIGNATED BY LOWER CASE LETTER AND CIRCUIT BY NUMBER (WHERE APPLICABLE). WHEN CONDUCTOR OR CONDUIT SIZE IS INDICATED FOR BRANCH CIRCUIT HOME RUN, THE CONDUCTOR AND CONDUIT SIZE INDICATED SHALL BE USED FOR THE COMPLETE CIRCUIT. REFER TO THE AKCHITECTURAL/INTEKIORS DOCUMENTS FOR ACTUAL DEVICE LOCATIONS AND DIMENSIONS. REFER TO THE APPROPRIATE DRAWINGS FOR THE EXACT LOCATION OF EQUIPMENT INSTALLED UNDER OTHER DIVISIONS OF THE DOCUMENTS, WHICH REQUIRE ELECTRICAL SERVICE. REFER TO APPROPRIATE DRAWINGS AND MANUFACTURER'S INSTALLATION MANUAL TO PROVIDE ALL SUPPLEMENTARY AND CONTROL CIRCUITS TO BRING EQUIPMENT TO FULL WORKING CONDITION. EQUIPMENT GROUNDING CONDUCTORS SHALL BE INSTALLED IN ALL RACEWAYS. WALL SWITCHES CONTROLLING CIRCUITS OF OPPOSITE PHASES SHALL NOT BE INSTALLED IN COMMON BOX UNLESS PERMANENT BARRIER IS PROVIDED. ALL RACEWAY AND EQUIPMENT SUPPORTS AND HANGERS SHALL BE FULLY COORDINATED WITH STRUCTURAL DRAWINGS. REFER TO THE AKCHITECTURAL/INTERIOR5 DOCUMENTS FOR ACTUAL DEVICE LOCATIONS AND DIMENSIONS. FIELD VERIFY LAYOUT WITH EXISTING CONDITIONS AND STRUCTURE PKIORTO BEGINNING INSTALLATION, SEE HVAC DRAWINGS FOR LOCATIONS OF EQUIPMENT TO BE POWERED. COORDINATE WITH EQUIPMENT CUT5HEET5 AND PROVIDE ADDITIONAL CONTROL CIRCUITS IF REQUIRED BY MANUFACTURER. GENERAL DIAGRAMMATIC RACEWAY INTERCONNECTIONS OF EQUIPMENT, FIXTURES AND DEVICES ARE INDICATED ON FLOOR AND REFLECTED CEILING PLANS, REFER TO STRUCTURAL AND ARCHITECTURAL PLANS FOR ELEVATION CHANGES AND RACEWAY ROUTES. EACH PENETRATION OF A FIRE RESISTANT RATED ASSEMBLY BY A PIPE, TUBE WIRE OR CONDUIT SHALL BE PROTECTED BY A THROUGH PENETRATION FIRE STOP SYSTEM THAT HAS BEEN TESTED ACCORDING TO A5TM E8 14 OR E 193. ELECTRIC RECEPTACLES, SWITCHES, OUTLETS, ETC. SHALL NOT BE INSTALLED BACK TO BACK ON FIRE RESISTANCE RATED WALLS. THEY SHALL BE AT LEAST 24-INCHE5 APART. REFER TO ARCHITECTURAL DEMOLITION PLAN AND REMOVE ALL ELECTRICAL DEVICES NO LONGER USED, INCLUDING BUT NOT LIMITED TO OUTLETS, BOXES, CONDUITS, WIRES AND SWITCHES. ABBREVIATIONS AC G" ABOVE COUNTER SPACE OR 42" AFF IG ISOLATED GROUND AF AMP PU5E 15C SHORT CIRCUIT CURRENT AFF ABOVE FINISHED FLOOR LTG LIGHTING AL ALUMINUM MTD MOUNTED BFC BELOW FINISHED CEILING N NEUTRAL BKR BREAKER NL NIGHT LIGHT CND CONDUIT NEC NATIONAL ELECTRICAL CODE CONN CONNECTED OR CONNECTION PNL PANEL CTB CABLE TV TERMINAL BACKBOARD RECPT RECEPTACLE CU COPPER TEL TELEPHONE DN DOWN TTB TELEPHONE TERMINAL BOARD EC EMPTY CONDUIT TV TELEVISION ELEC ELECTRICAL TV55 TRANSIENT VOLTAGE SURGE SUPPRESSOR FACP FIRE ALARM CONTROL PANEL TYP TYPICAL FAA FIRE ALARM ANNUNCIATOR PANEL XFMK TRANSFORMER G OR GRIND GROUND UG UNDERGROUND GFCI OR GF GROUND FAULT CIRCUIT INTERRUPTER WP WEATHERPROOF Panel ROOM VOLTS 208Y/ 120V 3P 4W AIC O EXISTING MOUNTING SURFACE BUS AMPS 200 MAIN BKR MLO A FED FROM D5C NEUTRAL 100% LUGS STANDARD NOTE CKT CKT LOAD CKT CKT LOAD # BKR KVA CIRCUIT DESCRIPTION # BKR KVA CIRCUIT DESCRIPTION I 20/ 1 1.1 LIGHTING a 2 20/ 1 1.4 RECEPTACLE 3 20/ 1 0.1 LIGHTING b 4 20/ 1 0.2 RECEPTACLE 5 20/1 I .G U-2, MICROWAVE c G 20/1 0.5 RECEPTACLE 7 20/ 1 1.2 REFRIGERATOR a 8 20/ 1 0.4 RECEPTACLE 9 GO/3 I G.0 LXI5TING RTU b 10 GO/3 I G.0 EXISTING RTU 11 c 12 13 a 14 15 2011 0.4 RECEPTACLE b I G 2011 1.5 FITNESS EQUIPMENT 17 2011 0.4 RECEPTACLE c 18 2011 1.5 FITNESS EQUIPMENT 19 2011 1.0 WASHER a 20 2011 0.7 RECEPTACLE 21 30/2 .5.2 DRYER b 22 2011 0.5 RECEPTACLE 23 1' c 24 20/ 1 1.5 WH-1 25 20/ 1 1.0 TEL BACKBOARD a 2G 2011 0.9 RECEPTACLE 27 20/ 1 0.4 RECEPTACLE b 28 2011 0.5 RECEPTACLE 29 2011 0.1 EF- I c 30 2011 O.G WATER COOLER 31 20/ 1 0.4 EX. ROOF RECEPTACLE a 32 20/ 1 0.0 SPACE 33 2011 0.0 SPACE b 34 20/ 1 0.0 SPACE 35 2011 0.0 SPACE c 3G 2011 0.0 SPACE 37 2011 0.0 SPACE a 38 2011 0.0 SPACE 30 2011 0.0 SPACE b 40 2011 0.7 RECEPTACLE 41 2011 0.0 SPACE c 42 20/ 1 f .2 SIGNAGE CONK. KVA CALL. KVA CON N . KVA CALC. KVA LIGHTING 2.5 3.1 (1 25%) CONTINUOUS 0.0 0.0 (1 25%) LARGEST MOTOR I G.0 4.0 (1 25%) HEATING 0.0 0.0 (100%) OTHER MOTORS 4.7 4.7 (100%) NONCONTINUOUS 9.3 9.3 (1 00%) RECEPTACLES 7.4 7.4 (50%> 1 O) KITCHEN EQUIP 1.2 1.2 (100%) NONCOIN/DIVERSE 0.0 0.0 (N/A) TOTAL KVA 57.1 G 1.7 BALANCED THREE PHASE AMPS 1 71 .2 PHASE BALANCE PERCENT: PHASE A 98.7% PHASE B 92.9% PHASE C 109% 0 �\ \ \\ U v< z W zgzo G nz u 0'0 T PROFICIENT a =ww z amp E N G I N E E R I N G a==w oc oLL°= 6991 Peachtree Industrial Blvd Building 700 _ �woow Peachtree Comers, Georgia 30092 LU z o 404.330.9798 a w 3 z ow�a PROJECT # 118166 0 m 3 w ..=CzzLL CD` ,azao O . 67193 RTE *44,rrrnrrALinnp0" �'`• F.0 N O c� 0 QU Z Z (D W N LL 04 LL 4 Q W � r W 2 LO 00 Z It Q Z lcl� w Q U W W W LL �U L0 It PT SOLU I,3S VJ Z 0 !0 V ) E-2 T_ 014, U Q or) M LL W J O J LL J m J J Q 2 O= d o d N tiNW COMcheck Software Version 4.0.8.1 Interior Lighting Compliance Certificate Project Information ;Energy Code, 2017 Florida Building Code, Energy Conservation Project Title;_ Project Type; New Construction (Construction Site: OwnerfAgent: Designer/Contractor. Additional Efficiency Package(s) Reduced interior lighting power, Requirements are implicitly enforced within interior fighting allowance calculations_ Allowed Interior Lighting Power A B C Area Category Floor Area Allowed (ft2) Watts / ft2 1-Gymnasium 2230 0 8.5 Proposed Interior Lighting Power A Fixture ID ; description / Lamp 1 Wattage Per Lamp / (Ballast n LED: C. 6 SUSPENDED LED CYLINDER-- Other.: LED: D1: 6'RECESSED DOWNLIGHT: Other: LED: D2: 6" REGES ED DOWNLIOHT: Other., LED; L: 2' LED STRIP: Other: LED: Pi: LED LINEAR PENDANT Other: Interior Lighting Compliance Statement Total Allowed Watts = Allowed Watts (BXC) 1887 1887 B C D E. Lamps/ # of Fixture (C X D) Fixture Fixtures Watt. 1 3 8 23 1 1-3 13 166 1 2 13 26 1 1 21 21 1 19 52 988 Total Proposed Wafts = 1224 Compliance Statement. The proposed interior lighting design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed interior lighting systems have been designed to meet the 2017 Florida Building Code, Energy Conservation requirements in COMcheck Version 4.0.8.1 and to comply with any applicable mandatory requirements listed in the nspe�ction Checklist,, Brian M. Armenia y } ��� .� � �� �� � ._ ONOW20 8 Name - Title Signature Date Project Title: Report date: 04/091I8 r ` is F 18 $ Co ck Page 1 o 51 Data filenarrie; \\share.peiatl.co_ \projects\118\118166 PT Solutions Zephy_hil L\l 1 5 m e g f C405.2.1 Lighting controls installed to uniformly :[]Complies ',Requirement will be met. (EL1511 reduce the lighting load by at least :[]Does Not :C] Not. Observable :©Not Applicable C405,2.1 Occupancy sensors installed in :]Complies Requirement will be met, [EL18IF required spaces. :©Does Not ;]Not Observable; °]Not Applicable C40 2 1 ,independent lighting controls installed ;LtComplies= ; Requirement will be met. C4tk5 2 =per approved lighting plans and all -]Does Not all manual controls readily accessible and: C3Not Observable ; Ili L23ja . visible to occupants. ]Not Applicable C 4 Automatic Controls to shut off all ;OCom lies p Requirement will be met. building lighting installed in all ]Does Not : "buflcings. ®Not Observable ZONvt Applicable ; G 4Q5 3 . Daylight zones provided with ElComplies Requirement wilt be met. IN`L1�i individual controls that control the , ]Does_Not lightsindependent of general area , :]Not Observable ; lighting• ;l]Not Applicable , C405,2.3, Primary sidelighted areas are -.DComplies Requirement will be met. C405:2.3. equipped with required lighting []does Not 1, controls; (�t+ivt Observable C405.2 3. 2 E]Not Applicable [EL20]t C405.23, Enclosed spaces with daylight area ]Complies Exception: Requirement does not apply. C405.2.3. under skylights and rooftop monitors C(Does Not 1, are equipped with required light€ng ONbtObservable; C405".2.3, g controls. ;]Not Applicable [EL22ii C405,2,4 Separate lighting control devices for :LlComplies',Requirement will be met. [EL411 specific uses installed per approved ;Oboes Not lighting plans. :[]Not Observable :0Not Applicable C405,2A Additional interior lighting power mpl€es Requirement will be reset. [i 18I? allowed for special functions per the ']Does Not approved lighting plans and is DNot Observable automatically controlled and ONot Applicable ^ separated from general lighting: C4053 Exit signs do not exceed 5 watts per .QCompties :Requirement wilt be met. [EL613- face. ]Does Not :]Not Observable; E]Not Applicable C o m me nt5/ASS u m pti on s: _. e_W .._�___.._ ........ _ .__-.... High -impact {Tier 1S " ;Medium Impact (Tier 2} Low Impact (Tier 3} Project Title: Report date: 04/09118 Data filename: \tshare,peiatl,corn\projects\1181118166 PT Solutions Zephyrhilis FL\118166 corri.cck Page 3_of 5 COMcheck Software Version 4.0.8.1 Inspection Checklist Energy Code: 2017 Florida Building Code, Energy Conservation Requirements: 100.0% were addressed directly in the COMcheck software Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be metandhow that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. C405,6 Plans., specifications, and/or LJComplies Requirement will be met. [PR1711 ; calculations provide all information Oboes Not with which compliance can be [jNot Observable determined for the electrical systems ]Not Applicable and equipment and document where ' exceptions are claimed. Provisions are made for metering individual tenant units Feeder connectors (for feeder :and branch circuits) sized in accordance with approved plans with maximum drop of 50/c voltage drop total.. C103.2 Plans, specifications, and/or ]Complies Requirement will be met. [PR4}1 calculations provide all information ]Does Not 111with which compliance can be ❑Not Observable determined for the interior lighting Applicable and electrical systems and equipment ']Not and document where exceptions to ,the -standard are claimed, information ' provided should include interior lighting power calculations, wattage of bulbs and.bailasts, transformers and control devices. C406 Plans, specifications, and/or m M ❑Complies Requirement will be met. 1PR973 calculations: provide all information E] Does Not with which compliance can be (]Not Observable ` determined for the additional energy ❑Not Applicable efficiency package options, Additional Comments/Assumptions: i 1 ; H+glt impact (T€er 1J� tedium Impact (Tier 2} :Low €mpact (Tier 3} Project Title: Report date: 04/09/18 Data filename: \\share,peiatl com\projects\l18\118166 PT Solutions Zephyrhilis FLN118166 Com,cck. Page 2 of 5 FM'�t m►I� C>arni}xterir/ssu�s �y 4 Furnished M instructions for °]complies ERequiremcnt will be met. ^systems and equipment to the IlDoes Not building owner or designated representative, []Not Observable j ICIN[t Applicable C405.4.1 :Interior installed lamp and fixture Clcornplies ;See the Interior Lighting fixture schedule for values. IFI1811 lighting power is consistent with what ClDoes Not is shown on the approved lighting ]Not Observable! plans, demonstrating proposed watts 'E]Not Applicable are less than or equal to allowed watts b :z Furnished as -built drawings for Ocomplies Requirement will be met. Eelectric power systems within 90 days ©Does Not 1 flj] yof system acceptance. ]Not Observable ...._ ]Not Applicable ............................................................................................................®.. .._�...............,,.,......,..._............._......,,.. C408,3 Lighting systems have been tested to ............ ;m .,..,..........,....................................... _.........................._......................_............._..,...... ..... .._._........ ........._._...................................................... ❑Complies :Requirement will be met. ensure proper calibration, adjustment, ]Does Not 1IF1331', programming, and operation. 'CINot observable ]Not Applicable Additional, Comments/Assumptions: C l (High Impact (Tier 1} IMedlem Impact (Tier 2)Lcw Impact (Tier 3} Project Title: Report date:-: 04109/18 Data filename; \Lshare, pelatl.comlprojecMl18\1181+66 PT Solutions Zephyrhills FL\118165 Gom.cck Page 4 of 5 PROFICIENT E N G I N E E R I N G 6991 Peachtree Industrial Blvd Building 700 Peachtree Comers, Georgia 30092 404.330.9798 PROJECT # 118166 . 67193 �* -1. ORIDp N M 0 QU U Z z Z� LLLL N QL � LW cfl W = ti Z ao CD Q Z d' OQ Q ry ULU LL W 1 No PT SOLUTIONS Y Z Q0 'IT UQM M E-3 WASTENENT ISOMETRIC NO SCALE L-2 WMB LAV I y 2ji I y� SK 3' -1 T, /I2„ I2 I � � 12" 3" 1 I I 3'I LAV 1211 ( WMS 1 31 211 1 3�� EWC) 3 12" 3, 3" EWC- I FLOOR PLAN - WASTE & VENT 1 /4"=1'-0" WC- I WC-1 L I WMB- I 8 _. . d , 12 MS I f y211 ���1Z7 I '- EWC- I KEYNOTES Q 2" V DN Q 3" S B/F * CONNECT TO EXISTING SANITARY SEWER. MAIN IN BUILDING. FIELD VERIFY EXACT LOCATION, DEPTH, AND DIRECTION Of FLOW PRIOR TO COMMENCING WORK. 3O 2" V A/C 4� CONNECT TO EXISTING VENT PIPING. FIELD VERIFY EXACT LOCATION PRIOR TO COMMENCING WORK. ® IY," S A/F IN WALL SLOPED @/," PER FOOT * CONNECT TO EXISTING ROUGH -IN AT PREVIOUS LAVATORY LOCATION. Q Y2" CW *Y2" HW DN 0 3/4" CW * %4" HW TO SHELF MOUNTED WATER HEATER, SEE DETAIL. Q V," CW A/C * CONNECT TO EXISTING WATER PIPING, FIELD VERIFY SIZE AND EXACT LOCATION. Q EXTEND'/, CW */2" HW IN WALL FKOM PREVIOUS LAVATORY LOCATION. ® DEMO EXISTING PLUMBING FIXTURE AND REPLACE WITH NEW. KEUEE EXISTING ROUGH -IN. I O DEMO EXISTING PLUMBING FIXTURE AND ASSOCIATED PIPING. CAP UNUSED PIPING BELOW FLOOR, IN WALL, OR ABOVE CEILING AS APPLICABLE. I I DEMO EXISTING PLUMBING FIXTURES AND ASSOCIATED PIPING IN THIS AREA, CAP UNUSED PIPING BELOW FLOOR, IN WALL, OK ABOVE CEILING AS APPLICABLE. PROFICIENT E N G I N E E R I N G 6991 Peachtree Industrial Blvd Building 700 Peachtree Corners, Georgia 30092 404.330.9798 PROJECT # 118166 w z�zo t= Fo- x �¢^i U �w�a 0 Q =ww � zooms LU L0 offi wf¢a o N�m3i Uj F C z G O O (� J `tu1nnuunu", �•``��j0�`N P KE * No. 70199 % c FLORIDP70N ALnaa���• >.ANCE. U W U Q N It O 75 C'7 QU (D ~ Z Z U Q w N LL 04LL Qw(9 W = � U)Z °O It Q Z ryCY Q (D Uw �LL W H ti U) d� LO 14, 1 PT 3c LUT;0 iS . ,:.. y z o� UQM 0 LLw� Z) 0 LL J_ m J O=J= cM (- O CL N ti N P-1 FLOOR PLAN -WATER 1 /4"=1'-0" 1 OVERALL FLOOR PLAN 04-09-2018 a ­.w..: .-,:. n,,-.,_,. -..•,. .,. „ - --- 1 n - - -- - ---- - - -- - - I -. " II1'I�II LEGEND — — COLD WATER PIPE — — — — — — HOT WATER PIPE S SANITARY PIPE — — — — — — — — VENT PIPE O— c PIPE UP / PIPE DOWN T PIPE TEE FROM TOP / TEE FROM BOTTOM E 4— PIPE CAP/ PIPE CONTINUATION —•—� BALL VALVE / CHECK VALVE FLOOR DRAIN / FLOOR SINK oc P-TRAP VENT THROUGH ROOF 'a CONNECTION TO EXISTING ABBREVIATION5 A/C ABOVE CEILING FFE FINISHED FLOOR ELEVATION A/F ABOVE FLOOR HW HOT WATER B/F BELOW FLOOR IMB ICE MACHINE BOX BFP BACKFLOW PREVENTEK L / LAV LAVATORY CD CONDENSATE DRAIN MS MOP SINK CONT CONTINUATION MV MIXING VALVE CW COLD WATER S / SAN SANITARY DN DOWN SK SINK ET EXPANSION TANK TYP TYPICAL EWC ELECTRIC WATER COOLER V VENT FCO FLOOR CLEANOUT WC WATER CLOSET FD FLOOR DRAIN WMB WASHING MACHINE BOX ELECTRIC WATER HEATER 5CH EDU LE TANK TAG RECOVERY 5ETPOINT ELECTRICAL BA515 CAPACITY WH- 1 30 GAL 8 GPH @ 80- RISE 1 20' 1 .5 KW RHEEM EG5P30 P ELECTRICAL PRIOR TO SUBMITTAL OR PURCHASE-THEPLUMBING CONTRACTOR SHALL VERIFY THE APPROPRIATE E ELEC R CHARACTERISTICS OF THE SELECTED WATER HEATER. COORDINATE DIRECTLY WITH THE ELECTRICAL CONTKACTOK AND THE POWER PANEL SCHEDULES ON THE ELECTRICAL DRAWINGS. PLUMBING FIXTURE SCHEDULE WATER RUNOUT WATER CONN. MARK DESCRIPTION WASTE WASTE VENT 5PECIFICATION RUNOUT CONN. CW HW CW HW WALL HUNG LAVATORY (AMERICAN STANDARD "LUCERNE," 0355.0 12) WITH CONCEALED ARM CARRIER MOUNTING (ZURN Z 123 1). PROVIDE 0.5GPM SINGLE HANDLE FAUCET WITH POLISHED CHROME FINISH (DELTA 50 1 LF-HGMHDF). HANDICAP DRAIN OFFSET W/GRID L- I LAVATORY (ADA) - WALL HUNG 2" 1 1/2" 2" 112" 1/2" 3/8" 3/8" DRAIN (Z_URN Z874G-PC) AND CHROME PLATED P-TRAP (ZURN Z5701 -PC). CHROME PLATED BiRA55 ANGLE SUPPLY STOPS WITH FLEX SUPPLIES (MCGU(RE H I G5). INSULATE OFFSET, TRAP AND SUPPLY LINES (TRUEBRO "LAVGUARD.." # 103 E-Z). PROVIDE MIXING VALVE TO TEMPER HOT WATER TO I 10 DEGREES (LAWLER 7MM', ASSE 1070, LEAD FREE). WALL HUNG LAVATORY (WHITEHAUS WH- 103K-W). PROVIDE 0.5GPM SIIIGLE HOLE, SINGLE HANDLE FAUCET WITH POLISHED CHROME FINISH (KOHLER K-97282-4). PROVIDE GRID L-2 LAVATORY - WALL HUNG 2" 1 1 /2 211 11211 1 /2 3/8 3/8 DRAIN AND CHROME PLATED P-TRAP. PROVIDE MIXING VALVE TO TEMPER NOT WATER TO I 10 DEGREES (LAWLER'TMM', ASSE 1070, LEAD FREE). FLOOR MOUNTED, ELONGATED ADA TANK TYPE WATER CLOSET (AMERICAN STANDARD "CADET PRO RIGHT HEIGHT," 21 5AA. 104), 1.25 GPF, WHITE VITREOUS CHINA, GRAVITY FED FLUSH ACTION, TOP OF RIM AT 1 G.S" AFF. HIGH EPFICIENCY'WATFRSENSF' LISTED. PROVIDE ALTERNATE TANK CONFIGURATION (2 1 5AA. 1 05) WITH TRIP LEVER ON RIGHT HAND WC- WATER CLOSET (ADA) - TANK TYPE 4" 3" 2" I/2" /2° SIDE IF NECESSARY TO HAVE LEVER ON MOST ACCESSIBLE SIDE OF WATER CLOSET. HEAVY DUTY OPEN FRONT SEAT. LESS COVER, WITH 5ELF-5U5TAIN[NG CHECK HINGE (BEMIS 105555C). CHROME PLATED BRASS ANGLE SUPPLY STOP WITH 1 2" LONG X 3/5" FLEX SUPPLY (MCGUIRE M I GG). BI-LEVEL WATER COOLER (ELKAY EZSTLBLFC) WITH GLASS FILLER ACCESSORY (ELKAY WATER COOLER (ADA) - BI-LEVEL, LK I I 10). ORIFICES AT 38 3/8" AND 327/8" AFF. 8 GPH OF 50DEG WATER @ BODEG EWC- I 2" 112" 2" 112 _-- 112" --- WITH GLASS FILLER ROOM TEMPERATURE. PROVIDE ACCESSORY APRON (LKAPREZL) IF INSTALLED ON AN 5PECIFICA F ION5 ALL WORK SHALL COMPLY WITH ALL STATE, CITY AND LOCAL CODES, RULES AND REGULATIONS. CONTRACTOR SHALL SECURE ALL REQUIRED PERMITS AND INSPECTIONS ASSOCIATED WITH THIS WORK, AND SHALL PAY ALL COSTS AND FEES INVOLVED. THESE DRAWINGS ARE DIAGRAMMATIC AND DO NOT REFLECT ALL POSSIBLE PHYSICAL CONDITIONS. REFER TO ARCHITECTURAL DRAWINGS FOR ALL DIMENSIONS AND EXACT LOCATIONS OF EQUIPMENT AND FIXTURES. THE CONTRACTOR IS RESPONSIBLE FOR REVIEWING THE ARCHITECTURAL, STRUCTURAL, CIVIL, MECHANICAL 4� ELECTRICAL DRAWINGS (AS APPLICABLE) TO ENSURE ALL PLUMBING WORK IS IS COORDINATED WITH PHYSICAL CONDITIONS. PROVIDE NECESSARY OFFSETS, RISES, AND PIPING TO COORDINATE WITH THE BUILDING STRUCTURE, WORK OF OTHER TRADES, AND CONNECT POINTS TO SITE UTILITIES (AS APPLICABLE). CONTRACTOR SHALL REVIEW ALL CONTRACT DOCUMENTS AND SHALL BE FAMILIAR WITH THE SCOPE AND REQUIREMENTS OF THIS PROJECT. ANY DISCREPANCIES OR LACK OF CLARITY IN THE DOCUMENTS SHALL BE IDENTIFIED TO THE AIE PRIOR TO THE SUBMISSION OF PRICING BIDS. WITH A SUBMITTED BID, CONTRACTOR IS ACCEPTING THESE DOCUMENTS AS SUFFICIENT DEFINITION OF THE SCOPE OF WORK, AND ANY ADDITIONAL COSTS BASED ON UNCLARITY OF CONTRACT DOCUMENTS WILL NOT BE CONSIDERED, CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND LOCATIONS FOR EQUIPMENT INSTALLATION PRIOR TO THE SUBMITTAL OF SHOP DRAWINGS. ALL EQUIPMENT AND DEVICES SHALL BE INSTALLED SUCH THAT THEY ARE EASILY ACCESSIBLE AND SERVICABLE. THIS EQUIPMENT INCLUDES, BUT IS NOT LIMITED TO: PLUMBING FIXTURES, WATER HEATERS, VALVES, CLEANOUTS, THERMOMETERS, GAUGES, STRAINERS AND TRAP PRIMERS. COORDINATE THE ELECTRICAL REQUIREMENTS AND CHARACTERISTICS OF ALL PLUMBING EQUIPMENT WITH THE ELECTRICAL CONTRACTOR PRIOR TO PURCHASING EQUIPMENT. ALL WO SHALL BE INSTALLED IN ACCORDANCE WITH THE BEST RECOGNIZED PRACTICE! IN THE FIELD WORK R R RA CONCERNED. MANUFACTURED ITEMS SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S PRINTED DIRECTIONS, SPECIFICATIONS AND RECOMMENDATIONS. THE CONTRACTOR 15 RESPONSIBLE FOR REVIEWING THE ARCHITECTURAL DRAWINGS TO ENSURE THERE IS ADEQUATE WALL THICKNESS SUCH THAT ALL WATER PIPING, SANITARY PIPING, VENT PIPING, WALL CLEANOUTS, HOSE BIBBS, NON FREEZE WALL HYDRANTS, AND RECESSED ACCESS PANELS WILL FIT IN WALL SPACE. CONTRACTOR SHALL NOTIFY THE ARCHITECT IF WALL SPACE IS INADEQUATE PRIOR TO COMMENCING WORK. UNLESS NOTED OTHERWISE, ALL DRAINAGE PIPING SHALL BE SLOPED AT A MINIMUM Of/5" PER FOOT 2" SANITARY PIPING AND ALL GREASE WASTE PIPING SHALL BE SLOPED ATY4 PER FOOT. DOMESTIC WATER PIPING SHALL BE PURGED OF DELETERIOUS MATTER AND DISINFECTED PRIOR TO UTILIZATION. PIPING TO BE FLUSHED AND STERILIZED IN ACCORDANCE WITH IPC G 10, 1 AND ALL APPLICABLE LOCAL AND STATE HEALTH DEPARTMENT STANDARDS. PIPE PENETRATIONS THROUGH FIRE RATED WALLS OR FLOORS SHALL HAVE EQUIVALENTLY RATED SLEEVES AND SHALL BE SEALED AND FIRE CAULKED WITH A U.L. LISTED FIRE STOPPING SYSTEM INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S LISTED DETAILS AND SPECIFICATIONS. THE CONTRACTOR SHALL OBTAIN EXACT WALL, FIXTURE, AND LAYOUT DIMENSIONS FROM THE ARCHITECTURAL DRAWINGS. THE CONTRACTOR 15 RESPONSIBLE FOR OBTAINING ROUGH -IN AND INSTALLATION DRAWINGS FOR ALL PLUMBING FIXTURES, KITCHEN EQUIPMENT AND OWNER FURNISHED EQUIPMENT (AS APPLICABLE), AND SHALL COORDINATE THE PLUMBING INSTALLATION PRIOR TO COMMENCING THE WORK, THE CONTRACTOR IS PESPONSLBLE FOR PROVIDING AND INSTALLING ALL NECESSARY VALVES, CONNECTIONS, TRAPS, ACCESS PANELS, UNIONS, ESCUTCHEONS, WATER HAMMER ARRESTORS, VACUUM BREAKERS, RELIEF VALVES, PIPE INSULATION, AND EQUIPMENT SPECIALTY DEVICES AS REQUIRED TO FACILITATE COMPLETE AND OPERATIONAL CONDITIONS WHICH ARE IN STRICT COMPLIANCE WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING WITH THE REQUIREMENTS OF THE COUNTY HEALTH DEPARTMENT AND OTHER LOCAL AUTHORITIES HAVING JURISDICTION REGARDING CROSS CONNECTION CONTROL OR OBTAINING A FOOD SERVICE PERMIT (AS APPLICABLE). REPORT ANY OBSERVED DISCREPANCIES TO THE AIE PRIOR TO COMMENCING WITH THE WORK. PLATFORM MOUNTED ELECTRIC WATER HEATER NO SCALE VACUUM RELIEF VALVE (WATTS LFN3G-M I OR EQUAL) THERMOMETER DIELECTRIC UNION (TYP) ENGINEERED SUSPENDED WATER HEATER PLATFORM SYSTEM BY'HOLDRITE,' INCLUDING GALVANIZED HOT WATER 5PEC1 FICATION5 WASTE AND VENT PIPING SYSTEMS AND ACCESSORIES SANITARY PIPING BELOW GROUND SHALL BE PVC SCHEDULE 40 TYPE DWV WITH SOLVENT WELD JOINTS. SOLVENT WELD JOINTS SHALL MEET ASTM T-702.3 AND ASTM D-2GG5. SANITARY PIPING AND VENT PIPING ABOVE GROUND SHALL BE PVC SCHEDULE 40 TYPE DWV WITH SOLVENT WELD JOINTS. SOLVENT WELD JOINTS SHALL MEET ASTM D-2GG5. WASTE AND VENT PIPING SHALL BE TESTED IN ACCORDANCE WITH THE GOVERNING CODES. AT A MINIMUM, WASTE PIPING SHALL BE TESTED WITH AT LEAST 10 FOOT OF WATER HEAD PRESSURE APPLIED. TESTING WITH AIR IS NOT ALLOWED. ALL VENTS THROUGH ROOF SHALL BE LOCATED AT LEAST 1 0'-0" AWAY FROM ANY AIR INTAKE, EVAPORATIVE COOLER, OR ANY OTHER DEVICE THAT WOULD DRAW AIR FROM THE VENT. FLASH AROUND ALL PIPES PENETRATING THROUGH ROOF WITH STANDARD MANUFACTURED FLA5HINGS. FLASHING SHALL BE SHEEI METAL WITH RUBBER GASKETS AND SHALL EXTEND INTO ROOFING AND UP PIPE DISTANCES IN ACCORDANCE WITH THE LOCAL CODE. DOMESTIC WATER SYSTEMS AND ACCESSORIES WATER PIPING ABOVE FLOOR: HOT AND COLD WATER PIPING ABOVE GROUND SHALL BE CPVC (CHLORINATED POLYVINYL CHLORIDE) SCHEDULE 40 WITH SOLVENT WELD JOINTS WHEN APPROVED BY THE AUTHORITY HAVING JURISDICTION. PIPING SHALL MEET ASTM D 2848 AND SHALL BE CERTIFIED BYTHE NSF INTERNATIONAL FOR USE WITH POTABLE WATER SYSTEMS. SOLVENT CEMENTS FOR CPVC PLASTIC PIPING SHALL MEET ASTM 1`437, ASTM P438 AND ASTM 1`439. ALL DOMESTIC HOT WATER PIPING SHALL HAVE A MINIMUM PRESSURE RATING OF I OOPSI AT 1 80°F DOMESTIC WATER PIPING SHALL BE TESTED IN ACCORDANCE WITH ALL GOVERNING CODES. PIPING SHALL BE PURGED OF DELETERIOUS MATTER AND DISINFECTED PRIORTO UTILIZATION. PIPING TO BE FLUSHED AND STERILIZED IN ACCORDANCE WITH IPC G I O. I AND ALL APPLICABLE LOCAL AND STATE HEALTH DEPARTMENT STANDARDS. BALL VALVES SHALL BE TWO-PIECE BRONZE BODY, LARGE PORT WITH SOLID, SMOOTH BORE CHROME PLATED BRASS BALL. SEATS SHALL BE REINFORCED TFE WITH TEFLON PACKING RING AND THREADED ADJUSTABLE PACKING NUT. PROVIDE STEM EXTENSION AS NEEDED TO PROVIDE HANDLE ON OUTSIDE OF PIPE INSULATION. VALVES SHALL BE APOLLO 70 OR EQUAL. 3ACKFLOW PREVENTERS SHALL BE INSTALLED IN ACCESSIBLE LOCATIONS FOR EASE OF TESTING AND SERVICING. FOR BACKPLOW PREVENTERS WITH VENT CONNECTIONS, ROUTE VENT LINE TO NEAREST DRAIN AND DISCHARGE WITH AIR GAP. BACKFLOW PREVENTERS SHALL BE TESTED IN ACCORDANCE WITH IPC 312. 10.2. CONTRACTOR SHALL PROVIDE CERTIFICATIONS THAT STATE DEVICES HAVE BEEN TESTED AND APPROVED. INSULATION INSULATE ALL DOMESTIC HOT WATER PIPING REGARDLESS OF MATERIAL. WHERE RECIRCULATED HOT WATER IS SHOWN, INSULATE ALL HOT WATER AND RECIRCULATION PIPING WITH 1 " THICK INSULATION PER CHAPTER 5 OF IECC. FOR NON -RECIRCULATED HOT WATER SYSTEMS, INSULATION THICKNESS SHALL BE AS FOLLOWS: PIPE UP TO 1": y" THICK INSULATION. PIPE 14" TO 2": 1 " THICK INSULATION FOR CPVC COLD WATER PIPING, INSULATE ALL HORIZONTAL PIPING 11" AND OVER LOCATED ABOVE CEILING. THE INSULATION SHALL BE 1 " THICK. FOR COPPER COLD WATER PIPING, INSULATE ALL HORIZONTAL PIPING LOCATED ABOVE CEILING AND ALL VERTICAL PIPING LOCATED IN AN EXTERIOR WALL. PIPE UP TO 1 ":y" THICK. PIPING ly" AND OVER: 1 11 THICK INSULATION INSULATION SHALL HAVE A K-FACTOR (AVERAGE THERMAL CONDUCTIVITY) NOT TO EXCEED 0.27 BTU-IN/(HXSQFTX°F). TANK TYPE WATER HEATERS WATER HEATERS SHALL BE U_L. LISTED AND SHALL MEET OR EXCEED THE STANDBY LOSS REQUIREMENTS OF U.S. DEFT. OF ENERGY AND CURRENT EDITION OF ASHRAEIIESNA 90. I WATER HEATERS SHALL HAVE 1 50PSI WORKING PRESSURE AND BE EQUIPPED WITH EXTRUDED HIGH DENSITY ANODE ROD AND HIGH TEMPERATURE CUTOFF SWITCH. WATER HEATERS SHALL BE THERMOSTATICALLY CONTROLLED AND SET TO 120' UNLESS OTHERWISE NOTED. WATER HEATERS SHALL BE INSTALLED ON SUSPENDED PLATFORM, STEEL STAND OR CONCRETE PAD, AS INDICATED ON DRAWINGS. WATER HEATERS SHALL HAVE A MINIMUM 3 YEAR LIMITED WARRANTY WATER HEATERS SHALL BE INSTALLED LEVEL AND PLUMB, FIELD COORDINATE EXACT WATER HEATER LOCATION. MAINTAIN MANUFACTURERS RECOMMENDED CLEARANCES, AND INSTALL SUCH THAT CONTROLS AND DEVICES ARE ACCESSIBLE FOR SERVICING. INSTALL SHUTOFF VALVES IN COLD WATER INLET AND HOT WATER OUTLET, INSTALL THERMOMETER ON HOT WATER OUTLET. WATER HEATER SHALL HAVE ASME RATED COMBINATION TEMPERATURE AND PRESSURE RELIEF VALVE IN TOP PORTION OF TANK (FACTORY OR FIELD INSTALLED). PIPE RELIEF VALVE OUTLET TO FLOOR DRAIN, MOP SINK,. INDIRECT WASTE RECEPTOR ORTO EXTERIOR. MAINTAIN CONTINUOUS DOWNWARD PITCH TOWARD DISCHARGE LOCATION AND PROVIDE AIR GAP AT DISCHARGE LOCATION. WHERE WATER HEATER DRAIN PAN IS INDICATED ON PLANS, ROUTE DRAIN TO SAME LOCATION AS RELIEF VALVE AND DISCHARGE WITH AIR GAP. COLD WATER BALL VALVE (TYP) CHECK VALVE THERMAL EXPANSION TANK (SEE PLMB FIXTURE SCHEDULE) IF NOT FACTORY PROVIDED, INSTALL ASME RATED TAP RELIEF VALVE (WATTS 40XL SERIES OR EQUAL) HARDWARE PROVIDI WITH KIT. REFER TC MANUFACTURER'S INSTALLATION INSTRUCTIONS FOR SPECIFIC DETAILS C ATTACHING BRACEE TO MASONRY WALL FRAMED WALL, ETC. TWO DIAGONAL BRACES ACROSS TOP OF WATER HEATER FIELD COORDINATE STRUCTURE ABOVI RIGIDLY SUPPORT I FOUR THREADED R CONTRACTOR SHA PROVIDE/2" THREA CONNECT TO EACI- FOUR CORNER BR/ DRAIN PAN WITH FACTORY PROVIDE PVC DRAIN CONNE (TYPICAL BOTH DEI OPTION 'A'- SUPPORT FROM WALL OPTION 'B' - SUPPORT FROM STRUCTURE ABOVE PROFICIENT E N G I N E E R I N G 6991 Peachtree Industrial Blvd Building 700 Peachtree Cornets, Georgia 30092 404.330.9798 PROJECT # 118166 H > w Z�Zo H 000N 2 2 � pro Q azow F- r- �Rm� Vr zOO zom= F 2 '.1.V ' oO. Zn0=, w �Qa3V p w w�>� =zoz0 C7 �azao 0 `��y�aaurr,►,rp i * : No. 70199 IOR10p •. � ,,. ��. G N E H U W H U N o2 MO �Q U V Z z(D �LLLLN QLL w LO LJJ = Il- 00 Z `./ Q Z a(D U10� w w LL = U) LO PT SOVL41TtONIS: Z O0 LO _ UQM LL. w � o � LL JJow ^ J m J (`,r) 2 J 2 Cn M -17 a o rl NI�� N 04-09-2018