Loading...
HomeMy WebLinkAbout7631 Gall Blvd (17)I U) FACILITY ADDRESS WALMART STORE #0706 7631 GALL BOULEVARD ZEPHYRHILLS, FL 33541 APPLICABLE CODES NFPA STANDARDS EDITION: NFPA 170 2018 NFPA 72 2016 NEC 70 2017 NFPA 101 2018 OTHER STANDARDS FLORIDA BUILDING CODE —EXISTING 2020 BUILDING, 7TH EDITION FLORIDA FIRE PREVENTION CODE (FFPC) 2020 7TH EDITION MIAMI—DADE COUNTY CODE SECTION 14-61 *BUILDING IS EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM. *FIRE ALARM SYSTEM: ADDRESSABLE, CLASS "B" SIGNALING LINE CIRCUIT, CLASS "B" NOTIFICATION APPLIANCE CIRCUIT *FIRE ALARM SYSTEM: 119 POINT MAX PER SLC LOOP PER MANUFACTURER SPECIFICATIONS. 0 SIEET INDEX EFPO ALARM COVER PAGE EFP1 ELECTRONIC FIRE PROTECTION PLAN EFP2 ELECTRONIC FIRE PROTECTION RISER AND CALCULATIONS ENGINEER PROJECT ENGINEER PROJECT DESIGNER PHONE NUMBER PROJECT DESIGNER EMAIL ADDRESS CONSULTANT JASON M. SCATES, P.E. BRYAN VAZQUEZ 479-636-5004 BRY@TEAMOFCHOICE.COM WALMART SECURITY ENGINEER ASSIGNED WALMART SECURITY ENGINEER LISA LESLIE PHONE NUMBER 479-360-3959 EMAIL ADDRESS LISA.LESLIE@WALMART.COM SECURITY MANAGER ASSIGNED WALMART SECURITY MANAGER PHONE NUMBER EMAIL ADDRESS DAVID WINSTEAD 479-640-0338 DAVID. WINSTEAD@WALMART.COM SECURITY TECHNOLOGY COORDINATOR ASSIGNED WALMART ALARM COORDINATOR JARED HOOD LOCAL CONTACTS I I EMONE79-360-2646 4HOOD@WALMART AIL ADDRESS JAREDER COM FIRE DEPARTMENT: PASCO COUNTY FIRE RESCUE 9731 CITIZENS DRIVE SUITE 230 NEW PORT RICHEY, FL 34654 (727) 847-8126 BUILDING OFFICIAL: PASCO COUNTY (CENTRAL PERMITTING) 8731 CITIZENS DRIVE NEW PORT RICHEY, FL 34654 (727) 847-8126 Ln Ld v N } Q) d. 0 U m _ J 6 N M /T�� V I? V CD Zo m Oz �o oco u ,'n -L, o N ~ " p -TOQ (J 1 O ,N N a zW C6 ��W o w Dui v_i oo} Fw z Ld aQZ W =�Z< 02wV1W ~� aN NOO V_1M'wwww���';''......JWaOwX 0 cw<owoN�wWWONam V1 h-Wo(xr-) Oi-awFw- Z Q—z•-Ow OUO 0ir O 3vawz'oyw'az�oz i- O—OO JWOZOw<gz< Q §Wm aawW002Fz0a cnZOwwFFLl ow wwowo��wxmrn na�S0 0- aio�Nz0_3LZ< iawwap 00 G O E- 00 ^ 0 o o �o Lv elf co co O O w N z 0 ISSUE BLOCK CHECKED BY: HOU DRAWN BY: BRY POSSESSION DATE: 09/15/22 DOCUMENT DATE: 10/26/22 ALARM COVER PAGE SHEET: FPO i --I- 1 I i 1 I I 1 1 1 1 1 11 _ 1 I 1_ vi I, I_ q I I i I ; I 1 1111,1 N (D E- O 0 L • r Q) m n m U) N j N � N Q O N N I \ �p O O N \ O O / 6 N V) W 0 Q 3 cn 0 c- 0 cf) I Q „ J 0 N a N - 0 0 6 0 N + O C N � N m 0 O N >- I m Q- �E n U) N � f co N / L N pi O c N Q) \ r7 N to 07 N o / w Ln ~ N z/ F 0 COMPLIANCE NOTES "PROPRIETARY SYSTEM" 1. THIS SYSTEM DESIGN IS BASED UPON COMPLIANCE WITH THE NATIONAL, STATE AND LOCAL CODES. THE OCCUPANCY CLASS IS MERCANTILE. THE FACILITY WILL BE PROTECTED THROUGHOUT BY A FULLY SUPERVISED FIRE SPRINKLER SYSTEM PER NFPA 13 AND NFPA 72. 2. ELECTRONIC SPRINKLER SUPERVISORY SERVICE IS PROVIDED AND IS PROPRIETARY SYSTEM UNDER NFPA 72. 3. FLOW SWITCHES WILL BE PROVIDED ON ALL SPRINKLER RISERS WITH ALARM ZONING COINCIDING WITH SPRINKLER ZONING. 4. TAMPER SWITCHES WILL BE PROVIDED ON ALL VALVES, AND WHERE APPLICABLE, ALL OTHER ELEMENTS ESSENTIAL TO THE PROPER OPERATION OF THE SPRINKLER WILL ALSO BE SUPERVISED. 5. REMOTE ANNUNCIATOR(S) WILL PROVIDE POINT IDENTIFICATION ALL DEVICES/ZONES IN ALPHANUMERIC DISPLAY, AND AT LEAST ONE WILL BE LOCATED AT A CONSTANTLY ATTENDED LOCATION ON SITE. THE FACU CABINET HAS NO ANNUNCIATOR OR USER INTERFACE CONTROLS, AND IS A CABINET HOUSING (NON -ANALOG ADDRESSABLE) CIRCUITRY ONLY. 6. AT LEAST ONE MANUAL STATION WILL BE INSTALLED AND LOCATED WHERE REQUIRED BY THE AHJ, PER NFPA 72. UNLESS OTHERWISE SPECIFIED BY THE AHJ, IT WILL BE LOCATED AT THE CONTINUOUSLY ATTENDED LOCATION ON SITE, PER THE DRAWINGS. 7. ONE SMOKE DETECTOR WILL BE INSTALLED ABOVE THE FACU IN ACCORDANCE WITH NFPA 72 AND ANY REMOTE LOCATIONS WHERE FIRE CONTROL EQUIPMENT IS INSTALLED. 8. AIR HANDLING UNITS IN EXCESS OF 2000 CFM WHICH INCLUDE DUCT SMOKE DETECTORS SHALL SHUT DOWN THEIR RESPECTIVE FANS AND CAUSE A "SUPERVISORY" SIGNAL ON THE FACU PER NFPA 90A. SEE SCOPE OF MECHANICAL CONTRACTOR SHOP DRAWINGS FOR DETAILS. 9. COOKING HOOD SUPPRESSION SYSTEM(S) (IF ANY) SHALL BE CONNECTED TO THE SYSTEM TO CAUSE AN "ALARM" SIGNAL UPON AGENT DISCHARGE, PER NFPA 17 AND NFPA 72. SEE SUPPRESSION CONTRACTOR'S SHOP DRAWINGS FOR DETAILS. (Ef 10. ALL NON -REQUIRED DEVICES INDICATED IN THE SUBMITTAL (IF ANY), ARE VOLUNTARILY PROVIDED AND ARE DESIGNATED AS "SUPPLEMENTARY" IN NATURE, AS DEFINED IN NFPA 72. 11. AUDIBLE AND VISUAL NOTIFICATION APPLIANCES ARE PROVIDED AS INDICATED ON THE PLAN. 12. WALMART SECURITY TECHNOLOGY WILL INSTALL THE FIRE ALARM WHERE LEGALLY ENTITLED BY LICENSING, PERMITTING, CERTIFICATION OR EXEMPTION. LOCAL CONTRACTOR TO BE USED ELSEWHERE. 13. OFF PREMISES, AUTOMATIC ALARM NOTIFICATION WALL BE VIA TWO APPROVED MEANS OF COMMUNICATION TO WALMART'S UL LISTED (UUFX) CENTER. SEE UL FILE #S3152-1 FOR CERTIFICATE INFORMATION. 14. WIRING WILL BE INSTALLED PER (THE NEC) NFPA 70 AND ALL OTHER APPLICABLE SECTIONS. ALL EQUIPMENT SHALL BE PROPERLY LISTED PER NFPA 72. 15. THIS SYSTEM IS DESIGNATED AS A "PROPRIETARY SUPERVISING STATION SYSTEM" IN ACCORDANCE WITH NFPA 72 WITH 24 HOURS OF STAND-BY POWER THEN 5 MINUTES IN "ALARM" PER NFPA 72. STORE MANAGEMENT PERSONNEL ARE DESIGNATED FOR 1 HOUR RUNNER SERVICE. 16. THESE NOTES DO NOT SUPERSEDE REQUIREMENTS OF OTHER TRADES, SPECIFICALLY INCLUDING MECHANICAL. ELECTRONIC FIRE PROTECTION PLAN DEMOLITION NOTES 1, ALARM INSTALLER TO MAINTAIN THE EXISTING FACU SYSTEM OPERATIONAL THROUGH THE REMODEL PROCESS AS REQUIRED BY CODE. 2. CONTRACTOR MUST VISIT THE BUILDING TO DETERMINE THE FULL EXTENT OF THE EXISTING FIRE PROTECTION WORK AND EXISTING CONDITIONS. BECOME TOTALLY FAMILIAR WITH THE DISCONNECTIONS, REMOVALS OF EXISTING FIRE ALARM EQUIPMENT, AND CONDITIONS IN THE PROPOSAL FOR THIS PROJECT. NO EXTRA COMPENSATION WILL BE PAID FOR LACK OF SUCH DETERMINATION, FAMILIARIZATION, AND/OR ALLOWANCE. 3. IN AREAS THAT DO NOT SHOW NOTIFICATION AND OR INITIATION DEVICES, EXISTING DEVICES SHALL REMAIN. 4. MAINTAIN A PRESENCE AT THE CONSTRUCTION MEETINGS AND KEEP UP WITH THE MOVES. IT IS RECOMMENDED THAT THE CONTRACTOR REMOVE ANY AFFECTED DEVICES PRIOR TO DEMO EXCEPT FOR CRITICAL AREAS THAT WILL NEED TO BE COORDINATED THE NIGHT OF THE MOVE. 5. QUANTITIES INCLUDES ASSOCIATED WIRING AND CONDUITS. NO ADDITIONAL COMPENSATION WILL BE GIVEN FOR WIRING AND CONDUIT REMOVAL. 6. SPLICES ARE NOT ACCEPTABLE, RUN NEW WIRE TO NEW AND EXISTING DEVICES AFTER DEMO. SCOPE OF WORK 1. AHU1; DISCONNECT EXISTING POPIT MODULE FROM EXISTING AHU1. CONNECT NEW POPIT MODULE TO NEW FACTORY INSTALLED DUCT DETECTORS. INSTALL AND CONNECT REMOTE TEST SWITCH (RTS). 2. AHU2; DISCONNECT EXISTING POPIT MODULE FROM EXISTING AHU2. CONNECT NEW POPIT MODULE TO NEW FACTORY INSTALLED DUCT DETECTORS. INSTALL AND CONNECT REMOTE TEST SWITCH (RTS). 3. AHU3; DISCONNECT EXISTING POPIT MODULE FROM EXISTING AHU3. CONNECT NEW POPIT MODULE TO NEW FACTORY INSTALLED DUCT DETECTORS. INSTALL AND CONNECT REMOTE TEST SWITCH (RTS). 4. MAINTAIN COMPLETE FUNCTIONALITY OF FIRE ALARM SYSTEM THROUGHOUT DURATION OF REMODEL. 5. COMPLETE NFPA72 RECORD OF INSPECTION AND TESTING FORMS UPON COMPLETION, AND ALL APPLICABLE COMPLIANCE INSPECTIONS. 6. CONTRACTOR SHALL SUPPLY ALL BRIDLE RINGS AND ALL OTHER ASSOCIATED MATERIALS FOR WIRE MANAGEMENT. 7. REFERENCE DEMOLITION NOTES FOR SCOPE OF WORK. ALARM SYMBOLS LEGEND PLAN SYMBOL QTY DEVICE DESCRIPTION SYMBOL PLAN QTY DEVICE DESCRIPTION FACU 1 EXISTING FIRE ALARM CONTROL NPS 2 EXISTING NOTIFICATION POWER SUPPLY ALTRONIX PANEL BOSCH D9412GV4 A = L1002ULADA n UNIT NUMBER FAC 2 EXISTING CONTROL NPS 1 EXISTING NOTIFICATION POWER SUPPLY ALTRONIX ANNUNCIATOR BOSCH D1256RB AL802ULADA n=UNIT NUMBER FAA 1 EXISTING SYSTEM ANNUNCIATOR AND FIRE ALARM KEYPAD O EXISTING DETECTOR SMOKE SMOKE BOSCH D1257RB BOSCH D27 THE 6 NEW AHU SMOKE DETECTOR a EXISTING MANUAL PULL STATION BOSCH FMM-100 (POINT OF CONNECTION ONLY) T }( 3 NEW REMOTE TEST SWITCH SYSTEM SENSOR RTS151 AIM 3 NEW/EXISTING POPIT 104 MODULE BOSCH D9127U PLAN ABBREVIATIONS (E)-EXISTING TO REMAIN (R)-RELOCATE (N)-NEW LOCATION: WALMART STORE #0706 7631 GALL BOULEVARD ZEPHYRHILLS, FL 33541 Ln W V N} (3)c �mm J- J N CID U v z °° Ln m 1 0 o o Lu � u ro u) (14 Onoa o N Ix �Ix a wZ"' co En LZ �zz``'w owls �o o �(n z- a2a*aZaowow vi<W(o.) aN> `cif tnm woOw OM<0000�w W-jC.�NU- a.�� �nk'wox0-oo�-awL-w Lj O 3:( < Lf-"wWRQOF-z om0000�z�zoa<6za Q viVa-Qr-ai�W��Fa w*LLJ MQ NwzF�dmONOOpNJ <Zo �wWvOv)M WOFm Owxvn ww V) �odDzoawa(Aaw�aR U) H- z Q H J V) z O U ISSUE BLOCK CHECKED BY: HOU DRAWN BY: BRY POSSESSION DATE: 09/15/22 DOCUMENT DATE: 10/26/22 ELECTRONIC FIRE PROTECTION PLAN EFP1 U) D o N � T N -C N Q- O N N � O � O N � O O / N O � W O Q Q 3 O U) C I J 0 Q. N N - �I 0 c N i N m N 0 N � I m0- =� n rn a N O �W N / i N pi O Q N N CIA r7 N tC) N 0 / z / a EXISTING FIRE ALARM SYSTEM INPUT/OUTPUT MATRIX SYSTEM INPUTS 1 FIRE ALARM SYSTEM AC POWER FAILURE 2 FIRE ALARM SYSTEM LOW BATTERY 3 OPEN CIRCUIT 4 GROUND FAULT 5 NOTIFICATION APPLIANCE CIRCUIT SHORT 6 BUILDING MANUAL PULL STATIONS 7 AREA SMOKE DETECTORS 8 SPRINKLER WATERFLOW IN BUILDING 9 HVAC AIR DUCT SMOKE DETECTORS 10 HOOD FIRE SUPPRESSION SYSTEM ALARM 11 SPRINKLER TAMPER SWITCH 12 BACKFLOW VALVE TAMPER 13 FAILURE OF SIGNAL TRANSMISSION 14 DRY SYSTEM HIGH LOW PRESSURE 5 BDA SYSTEM TROUBLE 6 - SYSTEM OUTPUTS FACP ANNUNCIATION NOTIFICATION REQUIRED FIRE SAFETY CONTROL R POD v�0�0.3 C - \-S.Gj\�C�Pv JP AZ � \��P \�� I,/ PS�P�� `� \v��,�c• AZN ��J Q P P Q Q SCOPE OF WORK C Description Device Quantity Sta ndby Current Total Standby Current Alarm Current Total Alarm Current ControlPanel D9412GV4 1 0.2250 0.2250 0.3000 0.3000 Battery Lead Supervision Module D113 1 0.0450 0.0450 0.0450 0.0450 SDI S litter SDI-9114 1 0.0300 0.0300 0.0300 0.0300 Dual Class AB NAC Module D192G 1 0.0350 0.0350 0.1000 0.1000 Dual Phone Line DACT Module D928 1 0.0200 0.0200 0.1000 0.1000 Annunciator / Keypad A D1256 1 0.1040 0.1040 0.2060 0.2060 POPEX Module D8125 1 0.0600 0.0600 0.0600 0.0600 POPITS D9127 107 0.0005 0.0535 0.0008 0.0856 Auxilary Relay Module D130 2 0.0600 0.1200 Dual from-C Relay (on Alann) D8130 1 0.0070 0.0070 0.0600 0.0600 12v-4w Smoke Detector D273THE 2 0.0150 0.0300 0.0360 0.0720 TOTALS TOTAL STANDBY 0.610 TOTAL ALARM 1.179 COMPUTATIONS TOTAL AMPS USED INSTANDBY= 0.610 X 24 HOURS = 14L628 AH TOTAL AMPS USED IN ALARM= 1.179 X 5 MIN = 0.098 AH +20%CONTINGENCY 2.945 AH TOTAL STANDBY BATTERY REQUIREMEVTS= 17.671 AH TOTAL BACKUP BATTERYPROVIDTD= 36.000 AH TOTAL BACKUP BATTERYREQUIREl)- 17.671 AH TOTAL BACKUP BATTERY RESERVED= 18.329 AH Existing (2)18 Ah batteries to provide 36 Ah at 12 volts WIRE LEGEND A - - - - - --••-••-••-• - - - ---•-••- FIRE ALARM SYSTEM 3pr #18 AWG FPL TWISTED B ----------------------------- NOTIFICATION CIRCUIT 1pr #12 AWG FPL ZIP C ----------------------------- EXISTING NOTIFICATION CIRCUIT 1pr #12 AWG FPL ZIP D PLENUM RATED CABLE FPLP SHALL BE UTILIZED IN PLENUM RATED CEILING AREAS ONLY WP = WEATHERPROOF CABLE SHALL BE PROVIDED AS REQUIRED (+) POSITIVE CIRCUIT POLARITY (-) NEGATIVE CIRCUIT POLARITY PLAN ABBREVIATIONS (E)-EXISTING TO REMAIN (R)-RELOCATE (N)-NEW ALARM SYMBOLS LEGEND PLAN SYMBOL QTY DEVICE DESCRIPTION SYMBOL PLAN QTY DEVICE DESCRIPTION FACU 1 EXISTING FIRE ALARM CONTROL NPS 2 EXISTING NOTIFICATION POWER SUPPLY ALTRONIX PANEL BOSCH D9412GV4 AL1002ULADA n=UNIT NUMBER FAC 2 EXISTING CONTROL NPS 1 EXISTING NOTIFICATION POWER SUPPLY ALTRONIX ANNUNCIATOR BOSCH D1256RB AL802ULADA n=UNIT NUMBER FAA 1 EXISTING SYSTEM ANNUNCIATOR AND FIRE ALARM KEYPAD 0- EXISTING SMOKE DETECTOR BOSCH D1257RB BOSCH D273THE ns 6 NEW AHU SMOKE DETECTOR a EXISTING MANUAL PULL STATION BOSCH FMM-100 (POINT OF CONNECTION ONLY) RTS }( 3 NEW REMOTE TEST SWITCH SYSTEM SENSOR RTS151 AIM %141MODULE NEW/EXISTING POPIT BOSCH D9127U SCOPE OF WORK CEN TR AL (E) (E)------N)-----------------N----------------- �N--------- TO EXISTING STATION_.._.._.._.._.._.. I M _.._.._.._.._.._.. I M _.._.. �.._.._.._.._.._.._.. I M_.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.. I M_.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.. I M _.._.._.._.._.._.._.._.._.. �._.._.. BURGLAR AND I I I : FIRE ALARM (WARM AR T I (N)_ _ (N) (N)- - (N) (N)- _ (N) i INITIATING DEVICES FA C U (E) F _.._.._........ S S _.._.._.._.._.._.._.. S _.._.._.._.._.._.._. S 1 800 530 9924#1) , EXISTING BOSCH CUSTOMER (N) (N) (N) I SERVICE � :*IRTS D9412GV4 � RTS I I� 1 IRTS � AHU1 AHU2 AHU3 12 VD C S (E) L------------------------------------------------------. J -(� P ABOVE FAC U I I I I i (� D A TA COURTESY DESK LIQUOR SALES VESTIBULE-GR :1 2VDC------ _.._.._.._.._.._.. TOEXISTING L.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.. F A C ------ FA C _.._.._.._.._.._.. FA A NOTIFICATION POWER D1256RB (E) E) E SUPPLIES #1-#3 D1256RB ( D1257RB ( ) ELECTRONIC FIRE 1 PROTECTION RISER DIAGRAM NOT TO SCALE LOCATION: WALMART STORE #0706 7631 GALL BOULEVARD ZEPHYRHILLS, FL 33541 V 1 LLB 7 N } �a 0 com ID N co co V �z m oZ c� S o � � G U U') O n 0 t 6 m v o a L• O N N C6 z (� a ��w 0 w v O_ ~ ZWO Oza Uj w <n z- of mmw*z9aeWUM01wo 0: aN>-c10 om%nwo3wm � aQSct onUl wwwJ5Na} OZ 3NQ0Ow86vLoo�o Q Zc`-iaOma�OiwCk:L < 3 J aWaWa�zFwwV)L))Qzw< �(IIZON� www OWOw F-- �ZONo ��o(ro :)F- �Oe'DzonW<vWwwa:<� N z Q J to z O U ISSUE BLOCK III CHECKED BY: HOU DRAWN BY: BRY POSSESSION DATE: 09/15/22 DOCUMENT DATE: 10/26/22 ELECTRONIC FIRE PROTECTION RISER AND CALCULATIONS