HomeMy WebLinkAbout7886 Gall Blvd (2)E ❑C lei ABBREVIATIONS SYMBOLS USED AS ABBREVIATIONS ANGLE EQ EQUAL OA OVERALL CENTERLINE EQUIP EQUIPMENT OH OVERHEAD PERPENDICULAR EXH EXHAUST PT PAINT (ED) 0 ROUND OR DIAMETER EXIST EXISTING PR PAIR R PROPERTY LINE EXP BOLT EXPANSION BOLT PNL PANEL EXP JT EXPANSION JOINT PLAS PLASTER ARCHITECTURAL EXT EXTERIOR PLAM PLASTIC LAMINATE AFF ABOVE FINISHED FLOOR FIN FINISH (ED) PL PLATE AP ACCESS PANEL FE FIRE EXTINGUISHER PMJ PREMOLDED EXPAN. JOINT ADJ ADJUSTABLE FHC FIRE HOSE CABINET PWD PLYWOOD ALT ALTERNATE FL FLOOR (ING) PC PORTLAND CEMENT ALUM ALUMINUM FD FLOOR DRAIN PP POWER POLE AB ANCHOR BOLT FTG FOOTING QUAN QUANTITY ANOD ANODIZED FND FOUNDATION QT QUARRY TILE APPROX APPROXIMATE FR FRAME RAD RADIUS ARCH ARCHITECT(URAL) FO FRAME OPENING REF, RE: REFERENCE AD AREA DRAIN FV FIELD VERIFY REINF REINFORCE (D) (ING) GA GAGE, GAUGE BSMT BASEMENT GALV GALVANIZED REQ REQUIRED BRG BEARING REV REVERSE (SIDE) GC GENERAL CONTRACT (OR) BM BEAM RH RIGHT HAND GL GLASS, GLAZING BTWN BETWEEN ROW RIGHT OF WAY GWB GYPSUM WALL BOARD BLK BLOCK HDWE HARDWARE R RISER BLKG BLOCKING HTG HEATING RD ROOF DRAIN BD BOARD HVAC HEATING/VENTILATION/ RM ROOM BW BOTH WAYS A/C AIR CONDITIONING RO ROUGH OPENING BOT BOTTOM RB RUBBER BASE HT HEIGHT BLDG BUILDING SAT SUSPENDED ACOUSTICAL TILE H HIGH CAB CABINET HM HOLLOW METAL SECT SECTION CPT CARPET (ED) HOR HORIZONTAL SHT SHEET CI CAST IRON HB HOSE BIB SIM SIMILAR CIP CAST -IN -PLACE lNCL INCLUDE (D) (ING) SPEC SPECIFICATION (S) CLG CEILING ID INSIDE DIAMETER SQ SQUARE CT CERAMIC TILE INSUL INSULATE (D) (ING) ST STL STAINLESS STEEL CLR CLEAR (ANCE) INT INTERIOR STD STANDARD CLO CLOSET INV INVERT STL STEEL COL COLUMN JAN JANITOR STO STORAGE COMB COMBUSTIBLE JT JOINT STRUCT STRUCTURAL CONC CONCRETE LBL LABEL TEL TELEPHONE CMU CONCRETE MASONRY UNIT LAM LAMINATE (D) TZ TERRAZZO CONST CONSTRUCTION LAV LAVATORY THK THICK CONT CONTINUOUS LH LEFT HAND T&G TONGUE AND GROOVE CONTR CONTRACT (OR) LT LENGTH T&B TOP AND BOTTOM CJ CONTROL JOINT MB MACHINE BOLT TOC TOP OF CONCRETE CORR CORRUGATED MFR MANUFACTURE (ER) TOS TOP OF STEEL CRS COURSE (S) MAS MASONRY TOW TOP OF WALL DTL DETAIL MO MASONRY OPENING T TREAD DIAG DIAGONAL MAT'L MATERIAL (S) T/S TUBE STEEL DIA DIAMETER MAX MAXIMUM TYP TYPICAL DIM DIMENSION MECH MECHANIC (AL) LINO UNLESS NOTED OTHERWISE DO DITTO MTL METAL UR URINAL DR DOOR MIN MINIMUM VERT VERTICAL DBL DOUBLE MISC MISCELLANEOUS VWC VINYL WALL COVERING DS DOWNSPOUT MT MOUNT VCT VINYL COMPOSITION TILE DWG DRAWING MTD MOUNTED WC WATER CLOSET DF DRINKING FOUNTAIN NOM NOMINAL WWF WELDED WIRE FABRIC EA EACH NIC NOT IN CONTRACT W WIDTH, WIDE EF EACH FACE NTS NOT TO SCALE WF WIDE FLANGE EJ EXPANSION JOINT NSG NON -SHRINK GROUT WO WITHOUT ELEC ELECTRIC (AL) NO NUMBER WD WOOD EWC ELECTRIC WATER COOLER OC ON CENTER EL ELEVATION OPG OPENING ENCL ENCLOSE (URE) OPP OPPOSITE OD OUTSIDE DIAMETER DRAWING LEGEND SYMBOL DESCRIPTION SYMBOL DESCRIPTION SECTION SECTION LETTER MASONRY WALL -BRICK (PLAN) INDICATOR T MASONRY WALL-CMU (PLAN) SHEET DRAWN EXTERIOR ELEVATIO ELEVATION LETTER TYPICAL WALL (PLAN) MARKER EXISTING SHEET DRAWN DETAIL NUMBER Y-134'-8" DEMO INSULATION -RIGID INSULATION (LOOSE OR BATT) WOOD -ROUGH PLYWOOD -LARGE SCALE CONCRETE CASED OPENING EARTH COLUMN LINE COLUMN GRID MARKER CUMULATIVE DIMENSION REVISION NUMBER KEYNOTE/EQUIPMENT, TOILET ACCESSORY AND PLUMBING SYMBOL 1 DETAIL REFERENCE SHEET DRAWN ELEVATION LETTER INTERIOR ELEVATION 8 MARKER / - A20 - - SHEET DRAWN � DETAIL NUMBER DETAIL INDICATOR SHEET DRAWN 2� 0144A) DOOR NUMBER (X)WINDOW TYPE DX PARTITION TYPE ELEVATION LEVEL INDICATOR AFF7 POINT OF REFERENCE BLDG SECTION LETTER SECTION f SHEET DRAWN ROOM NAME XXXI &WO 06# CITY OF ZEPHYRHILLS — PLANS FXAIIAINER C . ZEPHYRHILLS RETAIL RENOVATION RESPONSIBILITY SCHEDULE FURNISHED BY INSTALLED BY Orf ITEM U U ZZ 0f COMMENTS W F_ W I__ Q U 0 0 06 0 Q o U Q(D off a Q o Z SALES FIXTURES EXCEPT MWU BACK -LIT LIGHTS, AT&T GLOBE SIGNS LIGHT FIXTURES SALES FLOOR ONLY; BACK OF HOUSE SUPPLY & INSTALL BY LANDLORD CEILING TILE SALES FLOOR ONLY; BACK OF HOUSE SUPPLY & INSTALL BY LANDLORD CEILING GRID SALES FLOOR ONLY, AS NEEDED; BACK OF HOUSE SUPPLY & INSTALL BY LANDLORD QMI CABINET (ONE) CARPET (SALES FLOOR ONLY) EXCLUDES BASE SHOPPERTRAK AATV IT EQUIPMENT & WI-FI MUSIC IT EQUIP. NOT LISTED ABOVE DSL OR T-1 SERVICE EXTERIOR SIGNAGE SHEET INDEX ARCHITECTURAL A0.1 GENERAL PROJECT INFORMATION A0.2 LIFE SAFETY PLAN A2.1 ARCHITECTURAL FLOOR PLAN A2.2 FINISH PLAN A2.3 ENLARGED RESTROOMPLAN AND ELEVATIONS A3.1 REFLECTED CEILING PLAN A6.1 INTERIOR ELEVATIONS A7.1 POWER/DATA/FLOOR BOX PLAN A8.1 DOOR SCHEDULES AND HARDWARE MECHANICAL M001 MECHANICAL LEGEND AND ABBREVATIONS M002 MECHANICAL SPECIFICATION M101 FIRST FLOOR HVAC PLAN M501 MECHANICAL DETAILS M601 MECHANICAL SCHEDULES PLUMBING P001 PLUMBING NOTES, SPECIFICATIONS, AND SYMBOLS P101 PLUMBING FLOOR PLAN - DEMOLITION AND NEW WORK PLANS ELECTRICAL E100 ELECTRICAL LEGEND E200 POWER PLAN E300 LIGHTING PLAN E400 ELECTRICAL SPECIFICATIONS E500 ELECTRICAL SLAB PLAN GENERAL PROJECT NOTES A. THE ARCHITECT SHALL BE NOTIFIED IMMEDIATELY OF ANY DISCREPANCIES BETWEEN THESE DOCUMENTS AND ANY APPLICABLE CODES BY THE AGENT INVOLVED WITH THE GOVERNING AGENCY HAVING JURISDICTION. IT IS UNDERSTOOD THAT THE "FIELD INSPECTOR" FOR SUCH AGENCY HAS FINAL AUTHORITY TO APPROVE / DISAPPROVE PROJECT CONSTRUCTION AND CORRECTNESS OF ALL CODE RELATED ITEMS. B. EACH SUBCONTRACTOR IS CONSIDERED A SPECIALIST IN THEIR RESPECTIVE FIELD OR TRADE AND SHALL NOTIFY, PRIOR TO PERFORMANCE OF THE WORK. THE GENERAL CONTRACTOR AND THE ARCHITECT OF ANY WORK CALLED OUT IN THE DRAWINGS WHICH CANNOT BE FULLY GUARANTEED OR CONSTRUCTED AS DESIGNED OR DETAILED. C. THE CONTRACTOR SHALL VERIFY ALL SITE CONDITIONS PRIOR TO COMMENCING THE WORK AND IMMEDIATELY NOTIFY THE ARCHITECT IN WRITING OF ANY DISCREPANCIES. D. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND LOCATIONS OF ALL OPENINGS, BASES, AND SPECIAL PROVISIONS REQUIRED FOR EQUIPMENT, DUCTS, PIPING, CONDUITS, FINISH HARDWARE, ETC. AND IMMEDIATELY NOTIFY THE ARCHITECT IN WRITING OF ANY DISCREPANCIES. E. DO NOT SCALE DRAWINGS. ALL DIMENSIONS SPECIFIED SHALL GOVERN. F. WHERE CONSTRUCTION DETAILS ARE NOT SHOWN OR NOTED FOR ANY PART OF THE WORK, DETAILING SHALL BE THE SAME AS FOR OTHER SIMILAR FIRST CLASS WORK FOR THE TRADE INVOLVED. THE ARCHITECT SHALL BE NOTIFIED IMMEDIATELY OF ANY ALTERNATE NON-STANDARD OR UNTESTED METHOD(S) PROPOSED. G. GENERAL CONTRACTOR SHALL COORDINATE ARCHITECTURAL DRAWINGS WITH MECHANICAL AND ELECTRICAL, PLUMBING, CIVIL AND LANDSCAPE DRAWINGS. H. GENERAL CONTRACTOR SHALL MAINTAIN ALL EXISTING FIRE RATINGS DURING DEMOLITION AND CONSTRUCTION. DEALER CONTACT DEALER: MOBILECOM CONTACT: MIKE PRENDERGAST PHONE: 813-362-4837 EMAIL: MIKEPRENDERGAST@GETATT.COM GENERAL PLAN NOTES A. NO PLAN DEVIATIONS ALLOWED UNLESS APPROVED IN WRITING BY AT&T PROJECT MANAGER. B. NO ELECTRICAL OUTLETS OR DATA J-BOXES BEHIND MWU SHALL BE VISIBLE. C. DEALER TO VERIFY IN FIELD THAT THE FLOOR PLAN LENGTH AND WIDTH DIMENSIONS ARE ACCURATE; IF DISCREPANCY EXISTS, DISCUSS WITH AT&T PROJECT MANAGER. D. SALES / STOCK WALL SHOULD ALWAYS EXTEND PAST SALES FLOOR CEILING HEIGHT. E. REMOVE ALL EXISTING STICKERS OR GRAPHICS FROM EXTERIOR GLASS (UNLESS AT&T -APPROVED). F. LEVEL 4 WALL FINISH ACCEPTABLE, EXISTING TEXTURE OF WALL OKAY. G. DATA WIRING SHOWN IS PER COR STANDARDS; DEALER REQUIREMENTS MAY DIFFER BASED UPON DEALER -PROVIDED EQUIPMENT (POS TERMINALS, PRINTERS, ETC.). H. VERIFY WITH DEALER WHETHER ANY ELECTRICAL OR DATA ADDITIONS ARE NEEDED FOR THE LOCATION OF THE MUSIC EQUIPMENT. PROJECT LOCATION - VICINITY PROJECT SITEid - z pdi et e�raY >arsartr,v � Gmge� Ave Ginger rive N Gain Rd r n p,"Iev sary.t>rse_ fit ea FK sup center .a: VICINITY LOCATION MAP NORTH NTS N DESIGN INTENT NOTES CONSTRUCTION TYPE TYPE IIB, UNPROTECTED, NON-SPRINKLERED OCCUPANCY TYPE M- MERCANTILE BUILDING AREA�:T 15 TOTAL STORE AREA: 1,769 SF 20 TOTAL RETAIL AREA: 1,252 SF TOTAL BOH AREA: 517 SF AREA RATIO: 70% RETAIL 30% BACK OF HOUSE PROJECT LOCATION 7910 GALL BLVD ZEPHYRHILLS, FL, 33541 PROJECT SCOPE THIS PROJECT IS A TENANT FIT -UP OF AN EXISTING BUILDING SHELL BUILDING CODES 2010 FLORIDA BUILDING CODE 2010 FLORIDA MECHANICAL CODE 2010 FLORIDA PLUMBING CODE 2010 FLORIDA FUEL GAS CODE 2010 FLORIDA ACCESSIBILITY CODE 2010 FLORIDA FIRE PREVENTION CODE 2010 FLORIDA ENERGY CONSERVATION CODE 2008 NATIONAL ELECTRIC CODE TENANT IMPROVEMENT AREA: 1,769 SF OCCUPANT LOAD: 1,769 SF/ 30 SF PER OCCUPANT = 59 OCCUPANTS EXITS REQUIRED: TWO EXITS (PER CHAPTER 10, SECTION 1004.1.2) EXITS PROVIDED: TWO EXITS www.brph.com Copyright © 2014 Architects, Engineers 2727 Paces Ferry Road I Bldg 1 1 Suite 1800 Atlanta I Georgia 1 30339 770-933-9242 1 770-933-9246 f Offices in Melbourne, Orlando, West Palm Beach, Atlanta, Charleston, Seattle These plans are protected by Federal Copyright protection. Unauthorized use may result in an infringement action. ISSUE FOR PERMIT AND CONSTRUCTIOI,�� REVISION 0 r 11, I.A M Q LL W J J Z O c0 _j a W G = IV o W J ~ = CO J w a N O .'� - e A. ' e AR0/0�12048 ARCH/ENGR OF RECORD BRUCE A. LOTT AR0012048 DESIGNED BY BDR DRAWN BY KCC/ BJG CHECKED BY BAL PROJECT NUMBER C06898.057.01 DATE 08/13/14 TrRE GENERAL PROJECT INFORMATION DRAWING NO. AOe 1 3 EU n 5 M a LIFE SAFETY PLAN GENERAL NOTES www.brph.com Copyright © 2014 E C Is U_ ui >'C' L N N U_IA F- � L a T O NI T 0 O C Q 0 0 CD i co N 3 -0 O a� � L Q 6i N 6i 3 N N 00 COMPONENT: DOOR OCCUPANTS:29 UNITS: 0.2IN REQUIRED WIDTH: PROVIDED WIDTH: 5.8 IN 32 IN EXISTING 1 /2" MAX \ F.E. \ op 69, `3 \ 7 �i TENANT IMPROVEMENT AREA: 1,769 S.F. OCCUPANCY TYPE: MERCANTILE OCCUPANT LOAD: 59 PERSONS NO. OF EXITS REQUIRED: 2 EXIT WIDTH REQUIRED: 11.8 IN. NO. OF EXITS PROVIDED: 2 EXIT WIDTH PROVIDED: 64 IN. ALLOWABLE TRAVEL DISTANCE: 200' awbasamenEw 1=� .... =�,. III � III 59'_ I ♦♦ \ , \ 63'-9" (> 34'-6") 0 0 - - - - - - 0 - - - - - v III III i \ � \ b / \ L 0 \ O� \ - - - - - - \ F.E. .. :. .:1, QAZ. i 'M� a DISTANCE TO CLOSEST EXIT: 20' DISTANCE TO SECONDARY EXIT: 65' COMMON PATH OF TRAVEL: 6' 1100--ft"02 i LIFE SAFETY PLAN 1 /4" = 1'-0" AREA F WORK S("';"'*O"%E A. A 36" DOOR HAS A CLEAR WIDTH OF 32" AND HAS A 160 PERSON EXIT CAPACITY. B. 72" PAIR -DOOR HAS A CLEAR WIDTH OF 68" AND HAS A 340 PERSON EXIT CAPACITY. LIFE SAFETY PLAN LEGEND EXISTING WALL 1 HOUR RATED PARTITION NON -RATED PARTITION FIRE EXTINGUISHER- SURFACE MOUNTED, TYPE "2A1013C", LARSON MODEL # MPS. NUMBER OF OCCUPANTS MEANS OF EGRESS COMPONENT SERVED BY COMPONENT REQUIRED WIDTH EXISTING 112" MAX COMPONENT: DOOR OCCUPANTS: 30 UNITS: 0.2IN REQUIRED WIDTH: PROVIDED WIDTH: 6 IN 32 IN COMPONENT: OOR OCCUPANTS: 25 UNITS: 0.2 " REQUIRED WIDTH: 5" PROVIDED WIDTH: 32" MEANS OF EGRESS COMPONENT TAG WIDTH REQUIRED PER OCCUPANT PROVIDED COMPONENT WIDTH Architects, Engineers 2727 Paces Ferry Road I Bldg 1 I Suite 1800 Atlanta I Georgia 1 30339 770-933-9242 1 770-933-9246 f Offices in Melbourne, Orlando, West Palm Beach, Atlanta, Charleston, Seattle These plans are protected by Federal Copyright protection. Unauthorized use may result in an infringement action. ISSUE FOR PERMIT AND CONSTRUCTION REVISION 0 J W J J I..L W N ARCH/ENGR OF RECORD BRUCE A. LOTT AR0012048 DESIGNED BY BDR DRAWN BY KCC CHECKED BY BAL PROJECT NUMBER C06898.057.01 DATE 08/13/14 TITLE LIFE SAFETY PLAN ■s OTANT1II kI0 AO*2 1 2 3 n FLOOR PLAN GENERAL NOTES w L2 111 C 25 GUAGE 3 5/8" MTL STUD BRACE - SPACED 48" O.C. ALTERNATE DIRECTION STRUCTURE *4'-0" MIN Al + RT - All PYICTINr. FLOOR PLAN 1 /4" = 1'-0" WALL ANGLE CEILING, SEE RCP Q ACOUSTICAL INSULATION a AT ACOUSTICALLY RATED c� PARTITIONS z_ J_ W U 0 W U N1 4 %/$" 3 5/8" 25 GUAGE METAL STUDS 24" O.C. WITH 5/8" GYP BOARD EACH W (If SIDE, (STC49 W/3" INSUL, WHERE W REQUIRED) U) ACOUSTICAL INSULATION TRACK (RUNNER) ATTACHED MM SND MM LL TO FLOOR WITH POWER N ACTUATED PINS @ 24" OC MAX (SEE RCP) v r s N 3/4" MIN EMBEDMENT _ Cn FLOOR FINISH AND BASE, a _J /ir SEE FINISH SCHEDULE Nu ^ Y 1, a � GYP1. BOARD THRU CEILING PARTITION 5 Ni N1 1. CDo rn 0 CO01 PARTITION TYPE N 1 2 C 2 N STRUCTURE FLOOR FINISH AND BASE, SEE FINISH SCHEDULE THRU CEILING FURRING PARTITION 1"=1'-0" PARTITION TYPE N2 1 " = 1'-0" z Q J d c� z J W U 0 W U W J U_ W af W W UL PERMITS THE REPRODUCTION OF THE MATERIAL REPRINTED FROM THE UL PRODUCT DIRECTORY WITH PERMISSION FROM UNDERWRITERS LABORATORIES INC.@ COPYRIGHT© 2007 UNDERWRITERS LABORATORIES DESIGN No. U465 NONBERAING WALL RATING-1 HR. SCALE: 1 "=1'-0" 1. Floor and Ceiling Runners — (not shown) — Channel shaped runners, 3-5/8 in. wide (min), 1-1/4 in. legs, formed from min No. 25 MSG galv steel, attached to floor and ceiling with fasteners spaced 24 in. OC max. 2. Steel Studs — Channel shaped, 3-5/8 in. wide (min), 1-1/4 in. legs, 3/8 in. folded back returns, formed from min No. 25 MSG gals steel spaced 24 in. OC max. 3. Batts and Blankets* — (Optional) — Mineral wool or glass fiber batts partially or completely filling stud cavity. See Sheet A102 ACOUSTICAL INSULATION for more information. 4. Gypsum Board* — 5/8 in. thick, 4 ft wide, attached to steel studs and floor and ceiling track with 1 in. long, Type S steel screws spaced 8 in. OC. along edges of board and 12 in. OC Z in the field of the board. Joints oriented vertically and OO staggered on opposite sides of the assembly. When attached w to item 6 (resilient channels) or 6A (furring channels), wallboard Y m is screw attached to furring channels with 1 in. long, Type S Q Z steel screws spaced 12 in. OC. Y W Q AMERICAN GYPSUM CO — Types AG-C U) 0- BORAL GYPSUM — Types BG-C CANADIAN GYPSUM COMPANY — Types AR, C, IP-X2, SCX, SHX, WRC or WRX. CONTINENTAL GYPSUM COMPANY — Types CG-C, CG5-5, CG6-6, CG9-9, CGTC-C. G-P GYPSUM CORP, SUB OF GEORGIA-PACIFIC CORP —Types 5, 9, C, GPFS6. LAFARGE GYPSUM, A DIVISION OF LAFARGE CORP. —Types LGFC6, LGFC-C. NATIONAL GYPSUM CO, CHARLOTTE, NC — Types FSK-G, FSW-G. NATIONAL GYPSUM CO, RIYADH, SAUDI ARABIA — Types FIR OR WR. PABCO GYPSUM, DIV OF PACIFIC COAST BUILDING PRODUCTS INC — Type PG-C REPUBLIC GYPSUM CO. — Type RG-C. STANDARD GYPSUM L L C — Types SG-C. TEMPLE -INLAND FOREST PRODUCTS CORP — Type TG-C. UNITED STATES GYPSUM CO — Type AR, C, IP-X2, SCX, SHX, WRC or WRX. YESO PANAMERICANO SA de CV — Type AR, C, IP-X2, SCX, SHX, WRC or WRX. WESTROC INC—Type WESTROC FIREBOARD. 4A. Gypsum Board* — (As an alternate to Items 4) — Nom 3/4 in. thick, 4 ft wide, installed as described in Item 4 with screw length increased to 1-1/4 in. CANADIAN GYPSUM COMPANY — Types AR. UNITED STATES GYPSUM CO — Type AR. YESO PANAMERICANO SA de CV — Type AR. 4B. Gypsum Board* — (As an alternate to Items 4 or 4A) — Nom 3/4 in. thick, 4 ft wide, installed as described in Item 4A with screw length increased to 1-1/4 in. CANADIAN GYPSUM COMPANY — Types WSX. UNITED STATES GYPSUM CO — Type WSX. YESO PANAMERICANO SA de CV — Type WSX. 5. Joint Tape and Compound — Vinyl, dry or premixed joint compound, applied in two coats to joints and screw heads; paper tape, 2 in. wide, embedded in first layer of compound over all joints. As an alternate, nominal 3/32 in. thick gypsum veneer plaster may be applied to the entire surface of Classified veneer baseboard. Joints reinforced. 6. Furring Channel — (Optional -Not Shown) — 25 MSG galy steel resilient channels spaced vertically max 24 in. OC, flange portion attached to each intersecting stud with 1/2 in. long type S-12 panhead steel screws. *Bearing the UL Classification Marking PARTION TYPE N3 1" = 1'-0" A. GC TO INSTALL FIRE RETARDANT BLOCKING AS REQUIRED FOR ALL CASEWORK, SHELVING, COUNTERTOPS, & OWNER PROVIDED EQUIPMENT. B. PATCH CONCRETE SLAB AS REQUIRED TO REPAIR CONDUIT INSTALLATION. SEE ELECTRICAL FOR EXTEND OF SLAB TRENCHING. C. ALL DIMENSIONS ARE FINISH TO FINISH UNLESS NOTED OTHERWISE. D. MAINTAIN EXISTING FIRE RATINGS AT TENANT SEPARATION WALLS DURING DEMO / CONSTRUCTION ACTIVITIES. E. SEE REFLECTED CEILING PLAN ON SHEET A3.1 FOR ACT LAYOUT. F. ALL MILLWORK / CABINETRY PROVIDED BY FIXTURE VENDOR. G. SEE INTERIOR ELEVATIONS ON SHEET A6.1 FOR ALL WALLS WHERE NO FINISH OR BASE IS INDICATED. H. PAINT ALL SALES FLOOR DOORS AND FRAMES (ALUMINUM STOREFRONT NOT INCLUDED) TO MATCH ADJACENT WALL COLOR, USING A SEMI -GLOSS FINISH UNLESS NOTED OTHERWISE. J. ADD KICK PLATES ON ALL INTERIOR DOORS. ADD DOOR CLOSER AT RESTROOM DOORS. FLOOR PLAN KEY NOTES OCENTERLINES ARE USED TO LAYOUT STORE, INCLUDING CEILING, POWER / DATA, FIXTURES, ETC. AND MUST BE MARKED AND VARIFIED PRIOR TO START OF CONSTRUCTION. CONTACT ARCHITECT IMMEDIATELY IF THERE ARE DIMENSIONAL DISCREPANCIES. 2OLIGHT FIXTURE ABOVE - SEE RCP FOR LOCATION AND ADDITIONAL INFORMATION. OBOH - PARTIAL WORK TO BE COMPLETED IN THIS CONTRACT - OTHER PORTION N.I.C. SEE A2.2, A3.1 & R1.1 4O CENTER THIS FIXTURE ON (� OF SALES FLOOR. OADJUST LOCATION OF POSTER RAILS AS PER ACTUAL FIELD LOCATION OF EXTERIOR GLASS AND WINDOW MULLIONS. FIXTURE SCHEDULE QTY FIXTURE DESCRIPTION 1 44"X86" Sm Comm Table SMALL COMMUNITY TABLE 1 AATV-BENCH AATV BENCH 1 AATV-SML AATV Small 1 ACC-DIA DIAMOND ACCESSORY FIXTURE 1 ACC-LRG ACCESSORY FIXTURE 1 ACC-SML ACCESSORY FIXTURE 1 AT&T AT&T LOGO 1 BCW-MED BACKWRAP 3 BP Blocker Panel 1 IP-D L3 - 60" IPHONE FIXTURE 1 LT-D LEARNING TABLE I LT-D-ADA ADA LEARNING TABLE 2 LT-S LEARNING TABLE STOOL 2 LT-S-ADA ADA LEARNING TABLE CHAIR 1 MPOS MOBILE POINT OF SALE 1 MPOS-ADA MOBILE POINT OF SALE 11 MWU-D LEVEL 3 MERCHANDISE UNIT 2 WIN-B WINDOW BANNER WALL & DOOR LEGEND NEW CONSTRUCTION WALL EXISTING WALL TO REMAIN ® STOREFRONT GLAZING EXISTING DOOR TO REMAIN NEW CONSTRUCTION DOOR d EXISTING DEMISING WALL www.brph.com Copyright © 2014 Architects, Engineers 2727 Paces Ferry Road I Bldg 1 1 Suite 1800 Atlanta I Georgia 1 30339 770-933-9242 1 770-933-9246 f Offices in Melbourne, Orlando, West Palm Beach, Atlanta, Charleston, Seattle These plans are protected by Federal Copyright protection. Unauthorized use may result in an infringement action. ISSUE FOR PERMIT AND CONSTRUCTION REVISION L J m OC G 06 I— J Q W U) J J W N Z O w w W E.-OF F<O gruc��• i��O< ARCH/ENGROF RECORD BRUCE A. LOTT AR0012048 DESIGNED BY BDR DRAWN BY KCC/ BJG CHECKED BY BAL PROJECT NUMBER C06898.057.01 DATE 08/13/14 TITLE ARCHITECTURAL FLOOR PLAN DRAWING NO. A2* a U 0 N a U co 1 ! 2 3 El P i E C C U_ �i s o L NI N U_ , N Qr O NI O cd o CD rn O CO ih co 7j—D 0 0)N O U N d U co 410000 UNWHEM«322,p � s 'MANO . EWE 4a. 0 a:. P-4 TO 8'-0" AFF P-1 ABOVE 8'-0" AFF PROVIDE TRANSITION STRIP IF RB-1 DISSIMILAR FLOOR FINISH. ACT-2 SEE 1/A2.2 FOR REFERENCE P-1 RB-1 VCT-1 w Q U_ - SALES Q EO QUARTER -TURNED o w CARPET LAYOUT \ ao >p 1225 SF O- Q ~ d d Q' / \ P-4 TO 8'-0" AFF ° ACT-2 P-1 ABOVE 8'-0" AFF ACT-2 P-1 FRP RB-1 \ VCT-1 RB-1 o VCT-1 1 FINISH PLAN A2.2 1/4" = 1'-0" VCT FLOORING — TOP OF CONCRETE DIMENSION POINT VINYL EDGE STRIP-JOHNSONITE CE-XX-A, COLOR 63 BURNT UMBER — GLUE -DOWN CARPET U 6" JOHNSONITE MTC-00-A FLOORING TRANSITION 1 1 /2" = 1'-0" I- Z O of w w w O F_ 0 Z 0 0 J � , n w 4'-0" FINISH LEGEND ACT-1 USG FROST CLIMAPLUS #414 ACT-2 USG RADAR CLIMAPLUS #2420 EDGE: SLB EDGE: SLT SIZE: 2 X 2 SIZE: 2 X 4 COLOR: SILVERTONE #052 COLOR: FLAT WHITE GRID: DONN DX 15/16" GRID: DONN DX 15/16" GRID COLOR: SILVERTONE GRID COLOR: FLAT WHITE 800-950-3839 800-950-3839 P-1 BENJAMIN MOORE ALTERNATIVE: SHERWIN WILLIAMS "WEDDING VEIL" #2125-70 "EXTRA WHITE" #SW 7006 EGGSHELL ON WHITE GWB WALLS & SOFFITS EGGSHELL ON WHITE GWB WALLS & SOFFITS P-2 BENJAMIN MOORE ALTERNATIVE: SHERWIN WILLIAMS "SWEET INNOCENCE" #2125-50 "UPWARD" #SW 6239 EGGSHELL ON LIGHT GREY GWB WALLS, SALES EGGSHELL ON LIGHT GREY GWB WALLS, SALES FLOOR GWB COLUMNS, & ACT CEILING FLOOR GWB COLUMNS, & ACT CEILING ACCESSORIES ACCESSORIES SEMI -GLOSS ON LIGHT GREY DOORS, FRAMES SEMI -GLOSS ON LIGHT GREY DOORS, FRAMES P4 BENJAMIN MOORE ALTERNATIVE: SHERWIN WILLIAMS "ORANGE BURST" #2015-20L "INVIGORATE" #SW 6885 FGGSHELL ON ORANGE GWB WALLS & SOFFITS FGGSHELL ON ORANGE GWB WALLS & SOFFITS SEMI -GLOSS ON ORANGE DOORS & FRAMES SEMI -GLOSS ON ORANGE DOORS & FRAMES FRP FIBER -REINFORCED PLASTIC PLNELS AT 54" HIGH, COLOR: WHITE CPT-1 MFR: SHAW CARPET STYLE: ATT HIGH S[EED SQUARE #4546V COLOR: #BLUE STREAK #M5556 CONSTRUCTION: MULTI -SCROLL PATTERN: NO REPEAT 1/4 TURN CONTACT: MARK LAW 770-241-1345 INSTALL CPT-3 MFR: SHAW. STYLE: C0149 CINGULAR ENTRY COLOR: JET BLACK JB210 TYPE: 24" X 24" TILE MULTILEVEL LOOP 1/4 TURN MARK LAW, 770-241-1345 INSTALL VCT-1 ARMSTRONG IMPERIAL TEXTURE #51904 STERLING 12"x12"x 1/8" RB-1 JOHNSONITE ALTERNATIVE SUPPLIER: 82 BLACK PEARL GRAINGER SIZE: 4" (COVE BASE) (ROLL PRODUCT) ANDREW DODSON MIKE MATSON 404-806-8263, andrew.dodson@grainger.com 253-395-3639 ALSO COPY NOEL WELLS noel.wells@grainger.com NOTE: THE FRONT AND SIDES OF THE BACKWRAP FIXTURE (BCW) SHALL RECEIVE RB-1, AND THE FRONT AND SIDES OF AATV WALL FIXTURE (AATV) SHALL RECEIVE RB-1 www.bfph.com Copyright © 2014 Architects, Engineers 2727 Paces Ferry Road I Bldg 1 1 Suite 1800 Atlanta I Georgia 1 30339 770-933-9242 1 770-933-9246 f Offices in Melbourne, Orlando, West Palm Beach, Atlanta, Charleston, Seattle These plans are protected by Federal Copyright protection. Unauthorized use may result in an infringement action. ISSUE FOR PERMIT AND CONSTRUCTION REVISION L J Q w U) J J n w N ARCH/ENGR OF RECORD BRUCE A. LOTT AR0012048 DESIGNED BY BDR DRAWN BY KCC/ BJG CHECKED BY BAL PROJECT NUMBER C06898.057.01 DATE 08/13/14 TITLE Ln M M w J U. J J Z O a w N ct ow i m J a c� 0 r FINISH PLAN DRAWING NO. A292 err 11 11, tfl.i. 1 1 2 1 3 0 5 C1 www.brph.com Copyright © 2014 E IC L J U L r T O L N JA N u_ ,CO) Q� NI o� �o Q '0C")) w UOOD n N id N O �' v C 0 N U p N - a U ao y 1 ZC n ENLARGED RESTROOM PLAN 1 /2" = 1'-0" RESTROOM NOTES: (IF NOT INSTALLED) RESTROOM ACCESSORIES SHALL BE BOBRICK BRAND OR ARCHITECT APPROVED EQUAL AS LISTED BELOW ACCESSORY ITEMS MOUNTING HEIGHT �A SURFACE MOUNTED PAPER B-262 DISPENSING POINT AT TOWEL DISPENSER 4'-0" AFF SURFACE MOUNTED B-279 TOP AT 3'-4" AFF WASTE RECEPTACLE TOILET PAPER HOLDER B-264 CENTER AT 1'-7" AFF �C SOAP DISPENSER B-156 BOTTOM AT T-8" AFF �D GRAB BARS B-5806-42" TOP AT T-0" AFF �E GRAB BARS B-5806-36" TOP AT T-0" AFF ❑F MIRROR B-1658 BOTTOM AT 3'-4" AFF 24" X 36" ❑G VERTICAL GRAB BAR B-5806-18" BOTTOM AT T-3" AFF �H SURFACE MOUNTED B-7128 BOTTOM SCREW HOLE OF AUTOMATIC HAND DRYER S.S. FINISH MOUNTING BASE AT 4'-0" AFF Ja COAT HOOK B-6707 CENTER AT 4'-0" AFF S.S. FINISH ON CENTER OF DOOR 7 3 SHELF: PREMANUFACTU 36" WIDE SHELF. PARTICLE BOAR[ WIRE; PROVIDE 24" O.C.; COLOR: QCC -41A7 4 RED 12" DEEP, VINYL COATED OR WELDED oUPPORTS @ 31- 0'° 1001 WHITE F❑ \\ G C \ \\ 0 ¢ w OR Uj Z: i ll 31 _ OII 0 -- -- - z r�- B❑ CO - I �M _? c� o ' r co � ' r I I � � I � I N INSULATION KIT ON 1'- 6" WATER LINES; 1' - 6" TRUEBRO 102W: d- M COLOR: WHITE RESTROOM ELEVATION 1 /2" = 1'-0" SEE 1/A2.3 RESTROOM ELEVATION 1 /2" = 1'-0" k"J IT Architects, Engineers 2727 Paces Ferry Road I Bldg 1 I Suite 1800 Atlanta I Georgia 1 30339 770-933-9242 1 770-933-9246 f Offices in Melbourne, Orlando, West Palm Beach, Atlanta, Charleston, Seattle These plans are protected by Federal Copyright protection. Unauthorized use may result in an infringement action. ISSUE FOR PERMIT AND CONSTRUCTION REVISION 0 _I m O 06 Q J Q w U) J J r 0— W N IV Ln M M J LL_ J J a N J m 011. 0 r z O V W Uj U) %O . R11 i'+ �y _r/ii1 ARCH/ENGR OF RECORD BRUCE A. LOTT AR0012048 DESIGNED BY Designer DRAWN BY Author CHECKED BY Checker PROJECT NUMBER C06898.057.01 DATE 08/13/14 TITLE ENLARGED RESTROOM PLAN AND ELEVATIONS DRAWING NO. I� 0 RCP GENERAL NOTES E ❑C C U_2 T CM L NI (D U_ U) Q L _ am O NI 6o a 10C o � ri co a)_ a d o C N aU m OF SALES FI REFLECTED CEILING PLAN 1 /4" = 1'-0" LIGHTING FIXTURE SCHEDULE COUNT MARK MANUFACTURER MODEL LAMPS VOLT DESCRIPTION Qom. NO. 3 EXIT LITHONIA # EDG 1 120 ELN LED MT SINGLE -FACE EDGE LIT EXIT SIGN WITH BATTERY (VERIFY LED COLOR PER LOCAL CODE) CANOPY MOUNTED CMH MR16 MONOPOINT ACCENT LIGHT, LOCKING TILT AND ROTATION, ON -OFF SWITCH, ALUMINUM 25 F4A COOPER HALO STATIS L50516-20CMH-P-L111-LM50516-L973-AH 1 GE CMH2OMR16/830/FL 120 DIE-CAST HOUSING WITH VERTICAL ELECTRONIC BALLAST, SOFT CANOPY FOCUS LENS AND HOLDER, SQUARE MONOPOINT CANOPY ACCESSORY, ALUMINUM HAZE FINISH 48" DIAMETER LARGE SCALE SURFACE MOUNTED LUMINAIRE WITH WHITE ACRYLIC DIFFUSER, 20 GAUGE DIEFORMED STEEL 3 F12 LITE ENERGY / LIGHTOLIER LE/CS-441204XF25T8-120 4 GE F25/T8/SPX35/ECO 120 HOUSING, ELECTRONIC BALLAST(S), POLYESTER POWDER COAT MATTE WHITE FINISH VX4' RECESSED FLUORESCENT DIRECT LIGHT, HIGH 7 F16 COOPER METALUX GC332-UNV-EB81-U-1X4 3 GE F32W/T8/SPX35 120 REFLECTANCE WHITE POWDER COAT PAINT FINISH, TEXTURED MILK WHITE LENS FGW080 FRONT GLAZE ACRYLIC LENS, STANDARD FLANGE DESIGN WORKS WITH MOST LAY -IN CEILINGS, BACK-UP BATTERY PACK VX4' RECESSED FLUORESCENT DIRECT LIGHT, HIGH 3 F16EM COOPER METALUX GC332-120-FBP24H-EB81-U-1X4 3 GE F32W/T8/SPX35 120 REFLECTANCE WHITE POWDER COAT PAINT FINISH, TEXTURED MILK WHITE LENS FGW080 FRONT GLAZE ACRYLIC LENS, STANDARD FLANGE DESIGN WORKS WITH MOST LAY -IN CEILINGS, BACK-UP BATTERY PACK SECTION 0- PROMOTIONAL POSTER 1 1 /21'= 1'-0" INDEPENDENT LIGHT FIXTURE SUPPORT WIRE PER CODE INDEPENDENT SUPPORT CLIP W/ THREADED STUD & NUT ATTACHMENT ERICO PART NO. IDS OR EQUILIVENT. MIN 4 PER FIXTURE NOTE: CONTRACTOR TO USE MANUFACTURER -PROVIDED SPACERS F12 LIGHT FIXTURE WHEN INSTALLING TO A LAY -IN CEILING W/ TEGULAR TILES TO MAINTAIN THE INTENDED REVEAL. SECTION @ F12 LIGHT FIXTURE 1 1 /2" = 1'-0" A. LIGHT SWITCHES TO BE MOUNTED AT 42" AFF, UNO. B. SEE FINISH LEGEND FOR ACOUSTICAL CEILING PANEL INFORMATION ON SHEET A2.1 C. LIGHT FIXTURS ARE TO BE CENTERED ON CEILING PANELS, UNO. D. CONTACT ARCHITECT TO COORDINATE LIGHT FIXTURE LOCATIONS IF EXISTING CEILING GRID IS TO BE RE -USED. E. ALL LIGHT FIXTURES ARE TO BE ORDERED THROUGH GRAINGER PER NATIONAL AGREEMENT. VERIFY QUANTITIES PRIOR TO ORDER. F. ALL EXISTING DIFFUSERS & RETURN GRILLES ARE TO REMAIN IF APPLICABLE. PAINT ALL DIFFUSERS & RETURN GRILLES ON ACT-1 CEILING AT SALES FLOOR P-2. G. NOT ALL LIGHT FIXTURES MAY BE USED ON THIS PROJECT. GC TO VERIFY LIGHT QUANTITIES AND FIXTURES WITH QUANTITIES LISTED ON DRAWINGS. H. PROVIDE 100 LUMEN BATTERY BACKUPS IN EMERGENCY FIXTURES WHERE INDICATED ON DRAWINGS. J. CENTER ACT AND GRID IN SPACE UNO.. K. ALL CEILING LIGHTS (OTHER THAN NOTED EM'S) SHOULD BE SWITCHED. THE EXCEPTIONS WOULD BE THE MONOPOINT F4A LIGHTS IN THE FRONT STOREFRONT THAT SHINE LIGHT ON THE WALL BANNERS IN THE WINDOWS. THESE SHOULD BE TIED TO THE EXTERIOR SIGN TIMER SO THAT THEY COME ON AND LIGHT THE GRAPHICS ONLY WHEN DARK. OTHER THAN THIS, AT LEAST ONE PLUG BEHIND EACH MWU (PER PLAN) NEEDS TO BE ON A LIGHT SWITCH (WITH A DEDICATED SWITCH OR TWO FOR THIS LOCATED WITH THE OTHER SWITCHES ON A MAIN SWITCHBANK). PREFERRED LOCATION OF SWITCHBANK IS ON STOCKROOM SIDE OF SALES / STOCK WALL. L. CONTRACTOR TO USE MANUFACTURER -PROVIDED SPACERS FOR INSTALLATION OF F12 DOME LIGHTS WHEN INSTALLING TO A LAY -IN CEILING WITH TEGULAR TILES.. RCP KEY NOTES O O CENTERLINES ARE USED TO LAYOUT STORE, INCLUDING CEILING, POWER / DATA, FIXTURES, ETC. AND MUST BE MARKED AND VARIFIED PRIOR TO START OF CONSTRUCTION. CONTACT ARCHITECT IMMEDIATELY IF THERE ARE DIMENSIONAL DISCREPANCIES, O F4A IN FRONT OF THE POSTER RAILS THAT THEY SHOULD BE CENTERED WITHIN THE LENGTH OF THE RAILS. 3� BOH CEILING TO MATCH DWG IF NOT CURRENTLY IN PLACE. O SURFACE MOUNTED LIGHT FIXTURE; CONTRACTOR TO USE MANUFACTURER -PROVIDED SPACERS WHEN INSTALLING TO A LAY -IN CEILING W/ TEGULAR TILES TO MAINTAIN THE INTENDED REVEAL. O FIXTURE BELOW - REFER TO A2.1 FOR MORE INFORMATION AND EXACT PLACEMENT. O NEW CEILING GRID AND TILE FOR THIS SPACE. 7O LIGHT TO SHINE ON FIXTURE BELOW. gO LIGHT TO BE CENTERED ON FIXTURE BELOW. GC TO AIM LIGHT ON CENTER SHELF OF MWU (IF APPLICABLE) - REFER TO SHEET A2.1 FOR FIXTURE PLACEMENT INFORMATION. 9O EMERGENCY LIGHTS ARE SHOWN FOR REFERENCE ONLY, AND ARE THE RESPONSIBILITY OF THE ARCHITECT AND / OR ENGINEER OF RECORD TO DETERMINE FINAL LOCATION AND QUANTITY. 10 PREFERRED LOCATION FOR MAIN LIGHTING SWITCH BANK. ALL INTERIOR LIGHTS TO TERMINATE HERE. REFLECTED CEILING PLAN LEGEND 2' X 2' SUPPLY DIFFUSER 2' X 2' RETURN 2' X 4' FLUORESCENT LIGHT J1 1' X 4' FLUORESCENT LIGHT F16 ® EXIT LIGHT o RECESSED CAN LIGHT F3, F3A SPRINKLER HEAD RECESSED ADJUSTABLE MR16 METAL HALIDE F2, F2A 06 CANOPY MOUNTED CMH MR16 MONOPOINT ACCENT LIGHT, LOCKING TILT AND ROTATION, ON -OFF SWITCH, ALUMINUM DIE -AST HOUSING WITH VERTICAL ELECTRONIC BALLAST, SOFT FOCUS LENS AND HOLDER, SQUARE MONOPOINT CANOPY ACCESSORY, WHITE FINISH. CENTER LIGHT AS CLOSE AS POSSIBLE ON MWU. F4, F4A 4 FT DIAMETER SURFACE MOUNTED F12 FLUORESCENT FIXTURE U)-i LIGHT SWITCH www.brph.com Copyright © 2014 Architects, Engineers 2727 Paces Ferry Road I Bldg 1 1 Suite 1800 Atlanta I Georgia 1 30339 770-933-9242 1 770-933-9246 f Offices in Melbourne, Orlando, West Palm Beach, Atlanta, Charleston, Seattle These plans are protected by Federal Copyright protection. Unauthorized use may result in an infringement action. ISSUE FOR PERMIT AND CONSTRUCTION REVISION L RIM w J th Q NW 0. Cn J 1..1� w N ARCH/ENGR OF RECORD BRUCE A. LOTT AR0012048 DESIGNED BY BDR DRAWN BY KCC/ BJG CHECKED BY BAL PROJECT NUMBER C06898.057.01 DATE 08/13/14 TRLE REFLECTED CEILING PLAN DRAWING NO. A3. __7777i ill i ii�T 1 3 El 1.Iril 1 I, 131:I:,: 1 .... 5 0 ---- jOF BCW j CEILING__ 10'-0° V s E C I.7 J U_ ;= r ;o L N JA N LL C', E Q= a o N� 00LO Co OD CD S N U CO c5 7 c)0� N U p N a U ao SALES FLOOR 4 3/8" = 1'-0" 3 ELEVATION SALES FLOOR 3 A6.1 3/8" = 1'-0" ELEVATION @SALES FLOOR 2 3/8" = 1'-0" ELEVATION @SALES FLOOR 1 3/8" = 1'-0" k`------------%------------- P-1 CEILING 10'-0" FINISH FLOOR 0'-0" V CEILIN_G_/� 10'-0" V PAINT LINE 8'—On FINISH FLOOR /1 0' 0" PAINT LINE 8'-0" V FINISH FLOOR 0'-0" CEILING 10' oil PAINT LINE�� 8'-0" V FINISH FLOOR 0'-0" V ELEVATION GENERAL NOTES A. FOR ADDITIONAL FIXTURE INFORMATION, SEE A2.1 B. REFER TO FINISH LEGEND ON A2.1 FOR FINISH DESIGNATIONS. ELEVATIONS KEY NOTES 0 1O GC TO INSTALL RUBBER BASE (RB-1) @ BOTTOM AND SIDES BELOW TWO FIXTURES AFTER BEING INSTALLED BY GC: BACKWRAP FIXTURE (BCW) : THE FRONT AND SIDES SHALL RECEIVE RB-1, AATV WALL FIXTURE (AATV): THE FRONT SHALL RECEIVE RB-1 O PROMOTIONAL POSTER RAILS PROVIDED BY FIXTURE VENDOR, PROMOTIONAL POSTER PROVIDED BY OTHERS www.brph.com Copyright © 2014 Architects, Engineers 2727 Paces Ferry Road I Bldg 1 I Suite 1800 Atlanta I Georgia 1 30339 770-933-9242 1 770-933-9246 f Offices in Melbourne, Orlando, West Palm Beach, Atlanta, Charleston, Seattle These plans are protected by Federal Copyright protection. Unauthorized use may result in an infringement action. ISSUE FOR PERMIT AND CONSTRUCTION REVISION z\ ARCH/ENGR OF RECORD BRUCE A. LOTT AR0012048 DESIGNED BY BDR DRAWN BY KCC/ BJG CHECKED BY BAL PROJECT NUMBER C06898.057.01 DATE 08/13/14 TITLE INTERIOR ELEVATIONS DRAWING NO. A6,e E 01 3 n FLOOR PLAN GENERAL NOTES 10 10 POWER/COMMUNICATIONS REFERENCE PLAN 1 /4" = 1'-0" 3/8" = 1'-0" 3'-4" NOTE: WIREMOLD RFB4E FLOOR BOX W/ 2 HUB ACCESSORY AND 6CTBKTR COVER CAN BE USED IN PLACE OF THE 881RC4ATCBK IF BOX IS AVAILABLE. IF USED, CONDUIT WOULD TERMINATE AT BOX AND NO STUB -UP THROUGH FLOOR NOTE: RECEPTACLES @ BACKWRAP AND LEARNING TABLE TO BE ON A SINGLE 20 AMP DEDICATED CIRCUIT. DO NOT ADD OTHER RECEPTACLES TO CIRCUIT. NOTE: IF LEARNING TABLES ARE TO BE TEMPORARILY USED AS POS STATIONS. THE 2" CONDUIT SHOWN IN ENLARGED PLAN IS REQUIRED IN ORDER TO PROVIDE THE HDMI AND USB CORDS AND AMPLIFIER FROM THE BACKWRAP TO THE LEARNING TABLE. THE HDMI, USB, AND AMPLIFIER SHOULD BE ORDERED THROUGH GRAINGER AS REQUIRED. AREA OF WORK 5"L...-OPE OF BCW 3'-4" ------------------ -- OUTLE I FOR GRID GRAPHIC LIGHTING, TO BE NIGHT LIGHT I I t I 1 �— ---------+--r-----r-----� I 1 1 I I I I I I I I I I I I I I I I I 1 I I I I I I I I I I I I I I I I ! I I I I I I I I I I I I I I I 21 8 2 -$ 1 --—J-----1--—Q—' LQ----L— ---� I I I - V" ---- ---_ I I I I I I 1 1 I u to -------------+---- ------ --� FINISH FLOOR 2 POWER 4 DATA & 1 PHONE, 4 POWER ELEVATION @ BCW-MED 3/8" = 1'-0" A. GC TO PROVIDE ALL WIRING IN FULL COMPLIANCE WITH THE MOST CURRENT AT&T IT STANDARDS, RFP V2.5 OR LATER. B. ELECTRICAL INFORMATION SHOWN FOR REFERENCE ONLY. REFERENCE ELECTRICAL DRAWINGS FOR ENGINEERING DESIGN INFORMATION. C. DATA OUTLET INFORMATION SHOWN FOR LOCATION REFERENCE ONLY. REFERENCE ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION. D. PROVIDE PULL STRINGS IN ALL VOICE / DATA OUTLET CONDUIT. E. GROMMET LOCATIONS TO BE COORDINATED THROUGH GC WITH OWNER. F. SAWCUT AND REMOVE EXISTING SLAB SHOWN FOR NEW MEP WORK. COORDINATE LOCATIONS ON FIXTURE AND MEP DRAWINGS. PATCH AND REPAIR FLOORING AS NOTED. GC TO COORDINATE WITH LANDLORD'S ON -SITE REPRESENTATIVE PRIOR TO CUTTING OR DRILLING EXISTING SLAB. G. ALL FACEPLATES, PLUG AND SWITCHES SHOULD BE WHITE. THEY SHOULD NOT BE PAINTED. H. REUSING EXISTING SWITCHBANK IS OKAY AS LONG AS THE SWITCHES AND FACEPLATES ARE WHITE (OR REPLACED TO BE WHITE). IF NOT EXISTING, THEN LOCATE NEW SWITCHBANK ON STOCKROOM SIDE OF SALES/STOCK WALL. J. F4A FOR THE WINDOW BANNERS TO BE ON THE EXTERIOR SIGNAGE CIRCUIT AND TIED TO THE EXTERIOR SIGN TIMECLOCK. K. WI-FI SYSTEM (EQUIPMENT PROVIDED BY AT&T) REQUIRES A POA (POWER OVER ETHERNET) CONNECTION TO A SINGLE ACCESS POINT, WITH SUCH ACCESS POINT TO BE LOCATED ON THE CEILING NEAR THE MIDDLE OF THE STORE. POA TO EXTEND TO THE WI-FI EQUIPMENT LOCATION IN BOH. L. CONTRACTOR TO PROVIDE LABELING FOR THE DUAL SWITCHED/NON-SWITCHED ELECTRICAL OUTLETS BEHIND THE MWU'S. M. UNDERCARPET WIRING IS NOT ACCEPTABLE. FLUSH MOUNTED ELECTRICAL FLOOR BOXES MUST BE INSTALLED IN LOCATIONS NOTED PER PLAN. N. ANY DEALER -PROVIDED SECURITY EQUIPMENT TO BE WHITE OR SILVER COLOR ONLY, NOT BLACK. P. ANY CODE REQUIRED ALARM OR EMERGENCY LIGHTING DEVICES SHALL BE LOCATED ABOVE 8' AFF (WITHIN "WHITE" PAINT AREA), IF ALLOWED BY CODE. FLOOR PLAN KEY NOTES 0 O CENTERLINES ARE USED TO LAYOUT STORE, INCLUDING CEILING, POWER / DATA, FIXTURES, ETC. AND MUST BE MARKED AND VARIFIED PRIOR TO START OF CONSTRUCTION. CONTACT ARCHITECT IMMEDIATELY IF THERE ARE DIMENSIONAL DISCREPANCIES. O PROMOTIONAL POSTER RAILS PROVIDED BY FIXTURE VENDOR, PROMOTIONAL POSTER PROVIDED BY OTHERS. O BOH SHOWN FOR REFERENCE ONLY AND BY OTHERS, NIC. O NOT USED. 5O CONVENIENCE ELECTRICAL OUTLETS SHOWN MAYBE RELOCATED OF ELIMINATED AS PER DEALER DIRECTION. 6O FLOOR SAW CUTTING, CONCRETE REMOVAL, INSTALLATION OF DOWELS & WIRE MESH REINFORCING, REPOURING 4" CONCRETE SLAB SHALL BE BY THE GC. TRENCHING, INSTALLATION OF CONDUITS, BACKFILLING & COMPACTION OF BACKFILL BY ELECTRICAL CONTRACTOR. 4" CONCRETE SLAB SHALL BY DOWELLED INTO EXISTING SLAB WITH #5 DOWELS, 6" INTO EXISTING SLAB AND EXTEND T-0" INTO NEW SLAB POUR. THE NEW SLAB WIRE MESH REINFORCEMENT TO V-0" SECTION OR DOWEL STICKING OUT OF EXISTING SLAB. REFERENCE SHEET R1.1 FOR FLOOR BOX / STUB -UP LOCATIONS. O PROVIDE DUAL BRANCH CIRCUIT FOURPLEX RECEPTACLE; 2 OUTLETS SWITCHED (CONTROL FIXTURE LIGHTING), 2 OUTLETS HOT - PROVIDE BLACK ADHESIVE LABEL WITH 1/4" LETTERING INDICATING "SWITCHED FOR LTG" ADHERED TO THE HALF OF THE FOURPLEX PROVIDING POWER TO SWITCHED LIGHTING. CONNECT TO MAIN SWITCH BANK LOCATED AS PER RCP. O FIXTURE LIGHTS BEHIND AATV WALL MONITORS TO BE NIGHT LIGHTS. 9O RECEIPT PRINTER, 18" AFF DEDICATED CIRCUIT (MULTIPLE PRINTERS CAN SHARE THE SAME CIRCUIT). 10 NOT USED. 11 PROVIDE ONE OUTLET TO BE OFF -CENTERED ON DISPLAY ELEMENT (WINDOW BANNER). MOUNT TO CEILING ABOVE DISPLAY ELEMENT OR TO ADJACENT WALL ABOVE STOREFRONT WINDOWS AS NEEDED (SEE REFERENCE PLANS). ADD ADDITIONAL OUTLETS AS REQUIRED PER CODE. 12 2 DATA PORT IN CEILING FOR SHOPPERTRAK, FURNISHED AND INSTALLED BY OTHERS. CENTER OVER ENTRY DOOR. 13 DEDICATED 20 AMP CIRCUIT FOR THE ELECTRICAL BEHIND BACKWRAP. 14 1 DATA PORT IN CEILING FOR WIFI ACCESS POINT. DEALER TO HAVE AVAILABLE DUPLEX ELECTRICAL OUTLET IN "BACK OF HOUSE" AREA FOR WIFI EQUIPMENT; DEALER TO MARK LOCATION OF JACK ON CEILING TO HELP WIFI TECHNICIAN LOCATE; DEALER TO PROVIDE LADDER FOR WIFI TECHNICIAN'S USE. 15 TELCO BACKBOARD SEE ELECTRICAL FOR DETAILS. LOCATION TO BE VERIFIED BY DEALER. 16 ADDITIONAL ELECTRICAL OUTLET AND OR DATA / VOICE. POWER / COMMUNICATIONS REFERENCE LEGEND MEP DRAWINGS SHALL GOVERN DUPLEX OUTLET DUPLEX OUTLET DEDICATED QUAD OUTLET Ca COAXIAL CABLE OUTLET DATA OUTLET 0 VOICE OUTLET v VOICE / DATA OUTLET FLOOR DATA OUTLET ❑� FLOOR DUPLEX OUTLET 0 FLOOR QUAD OUTLET 0-i THERMOSTAT www.brph.com Copyright © 2014 Architects, Engineers 2727 Paces Ferry Road I Bldg 1 1 Suite 1800 Atlanta I Georgia 1 30339 770-933-9242 1 770-933-9246 f Offices in Melbourne, Orlando, West Palm Beach, Atlanta, Charleston, Seattle These plans are protected by Federal Copyright protection. Unauthorized use may result in an infringement action. ISSUE FOR PERMIT AND CONSTRUCTION REVISION A PEI Z O V W Of W U) OF F/_O ARCH/ENGR OF RECORD BRUCE A. LOTT AR0012048 DESIGNED BY BDR DRAWN BY KCC/ BJG CHECKED BY BAL PROJECT NUMBER C06898.057.01 DATE 08/13/14 TITLE POWER/ DATA/ FLOOR BOX PLAN DRAWING NO. A7. 1 1 I 2 3 I 4 5 I 6 E ❑C J U 7r > O L N N U-;A W L Q 1 NI C6o 0 MID L, CO 00 N C) of 0 C 2 N - i i) Q N o_ U OD HARDWARE SCHEDULE GROUP SPECIFICATIONS FINISH: US26D HW-1P EXTERIOR - WOOD/ METAL (EXISTING, REPLACE OR SUPPLEMENT ONLY AS NECESSARY) 3 PR BUTTS- STA FBB179-NRP- 4-1/2 X 4-1/2 1 THRESHOLD NGP 425 2 FLUSHBOLT QUA 1358-12 2 SWEEP NGP 102V 1 DEADLOCK BES 38H7K-626 1 SEAL NGP 5050-BN 2 PUSH/PULL SET QUA Q-484 1 ASTRAGAL BY DOOR SUPPLIER 2 CLOSER STA D4550-SB HW-1AP EXTERIOR - ALUM/ ALUM (EXISTING, REPLACE OR SUPPLEMENT ONLY AS NECESSARY) 3 PR BUTTS MFG STANDARD 1 THRESHOLD NGP 425 2 FLUSHBOLT MFG STANDARD 2 SWEEP NGP 102V 1 ALARM LOCK TRILOGY NARROW STILE ACCESS LOCK DL1325 1 SEAL MFG STANDARD 2 PUSH/ PULL SET QUA Q-484 1 ASTRAGAL MFG STANDARD 1 THUMBTURN BES 1E6A4-C181-626 2 CLOSER STA D4550-SB 2 DROP PLATE STA P45-180 HWAS EXTERIOR SINGLE- WOOD/ METAL (EXISTING, REPLACE OR SUPPLEMENT ONLY AS NECESSARY) 1-1/2 PR BUTTS STA FBB179-NRP- 4-1/2 X 4-1/2 1 THRESHOLD NGP 425 1 DEADLOCK BES 38H7K-626 1 SWEEP NGP 102V 1 PUSH/PULL SET QUA Q-484 1 SEAL NGP 5050-BN 1 CLOSER STA D4550-SB HWAAS EXTERIOR SINGLE - ALUM/ ALUM (EXISTING, REPLACE OR SUPPLEMENT ONLY AS NECESSARY) 1-1/2 PR BUTTS MFG STANDARD 1 CLOSER STA D4550-SB 1 DEADLOCK A/R MS1850S- 1-1/8 1 DROP PLATE STA P45-180 1 CYLINDER BES 1 E76-C181-RP-626 1 THRESHOLD NGP 425 1 THUMBTURN BES 1E6A4-C181-626 1 SWEEP NGP 102V 1 PUSH/ PULL SET QUA Q484 1 SEAL MFG STANDARD HW-2 PASSAGE WITH CLOSER 1-1/2 PR BUTTS, FBB179 - 4-1/2 X 4-1/2 - STA 1 KICKPLATE, 10" X 2" LDW - 16GA - QUA 1 PASSAGE BES 93KON 1 5D-S3-626 1 STOP, 431 ES -QUA 1 CLOSER STA D3550-SB 3 SILENCER, GJ64 - GJ HW-3 PRIVACY WITH CLOSER 1-1/2 PR BUTTS, FBB179 - 4-1/2 X 4-1/2 - STA 1 KICKPLATE, 10"X 2" LDW - 16GA - QUA 1 PRIVACY BES 93KOLl5D-S3-626 1 STOP, 431 ES -QUA 1 CLOSER STA D3550-SB 3 SILENCER, GJ64 - GJ HW-4 KEYPAD LOCK WITH CLOSER 1-1/2 PR BUTTS, FBB179 - 4-1/2 X 4-1/2 - STA 1 ALARM LOCK TRILOGY DL2800 ACCESS CONTROL SYSTEM 1 KICKPLATE, 10" X 2" LDW - 16GA - QUA 1 CLOSER STA D3550-SB 1 STOP, 431 ES - QUA 3 SILENCER, GJ64 - GJ HW-4A PUNCH LOCK KEYPAD LOCK WITH CLOSER 1-1/2 PR BUTTS, FBB179 - 4-1/2 X 4-1/2 - STA 1 LOCKSET BES #1021B-26D-41 PUNCH LOCK KEYPAD 1 KICKPLATE, 10" X 2" LDW - 16GA - QUA 1 CLOSER STA D3550-SB 1 STOP, 431 ES - QUA 3 SILENCER, GJ64 - GJ HW-5 OFFICE LOCK 1-1/2 PR BUTTS, FBB179 - 4-1/2 X 4-1/2 - STA 1 KICKPLATE, 10" X 2" LDW - 16GA - QUA 1 LOCKSET BES 93K7AB15D-53-626 1 STOP, 431 ES -QUA 1 CLOSER STA D3550-SB 3 SILENCER, GJ64 - GJ HW-6A EXTERIOR WITH LOCAL ALARM 1- 112 PR BUTTS STA FBB179-NRP- 4-1/2 X 4-1/2 1 THRESHOLD NGP 425 1 ALARM LOCK PRE PR-5101ALK501-689 1 SWEEP NGP 102V (1 ALARM LOCK PRE FL5101ALK501-689 WHERE FIRE RATED) 1 SEAL NGP 5050-BN 1 CYLINDER (IS) BES 1E74 1 RAIN DRIP NGP 16A+4 1 CLOSER STA D4550-SB 1 VIEWER IVE 698B 1 KICKPLATE QUA 10" X 2" LDW 16 GA HW-6B EXTERIOR WITH ALARM TO REMOTE LOCATION 1-1/2 PR BUTTS, FBB179 - NRP - 4-1/2 X 4-1/2 - STA 1 THRESHOLD, 425 - NGP 1 PANIC PRE 5101 WALW501-689-WH495-WTS 1 SWEEP, 102V - NGP 1 TRANSFER PRE EPT-5 1 SEAL, 5050 - BN - NGP 1 HORN ADE WAVE2EX 1 RAIN DRIP, 16A + 4" - NGP 1 CLOSER STA D4550-SB 1 VIEWER IVE 698E 1 KICKPLATE QUA 10" X 2" LDW 16GA 1 CYLINDER (IS) BES 1E74 HW-7 DOUBLE DOOR FOR MDF -ALL LOCKS TO BE KEYED WITH MASTERS $ SUB -MASTERS 3 PAIR BUTTS STA FBB179 - 4 1/2 X 4 1/2 2 FLUSHBOLT BY DOOR SUPPLIER 1 LOCKSET BES 7K SERIES 2 OVERHEAD STOP BY DOOR SUPPLIER 4 SILENCER GJ GJ64 1 T-ASTRAGAL BY DOOR SUPPLIER HW-8 MECHANICAL PUSHBUTTON LOCK 1-1/2 PR BUTTS, FBB179 - 4-1/2 X 4-1/2 - STA 1 KICKPLATE, 10" X 2" LDW - 16GA - QUA 1 LOCKSET SIMPLEX L1000 SERIES PUNCH LOCK KEYPAD 1 STOP, 431 ES - QUA 1 CLOSER STA D3550-SB 3 SILENCER, GJ64 - GJ MANUFACTURERS LISTING: STA STANLEY HARDWARE BES BEST LOCK IVE H.B. IVES QUA QUALITY HARDWARE NGP NATIONAL GUARD A/R ADAMS/RITE ARM ARM-A-DOR PRODUCTS PRE PRECISION HARDWARE GJ GLYNN-JOHNSON HARDWARE ADE ADEMCO 1'-01, 11-011 7" 6"41u4" I N CV ❑ r o c TEMPERED SAFETY GLASS; 1" `- THICK AT EXTERIOR DOORS; 1/4" o THICK AT z o INTERIOR o z DOORS � Omv~i A B C D E NEW OR NEW OR NEW OR NEW OR EXISTING STOREFRONT DOOR W/ TEMPERED EXISTING EXISTING EXISTING FLUSH DOOR W/ 7" X 22" GLASS FINISH: MATCH ADJACENT FLUSH SOLID FLUSH HOLLOW FLUSH DOOR ONE WAY GLASS PANEL CONSTRUCTION (STOREFRONT ENTRY) CORE WOOD METAL DOOR WITH 12" X 12" (MIRRORED ON SALES DOOR (REAR EXIT GLASS PANEL FLOOR SIDE) (SALES (RESTROOM) INVENTORY-) (MANAGER) FLOOR TO BOH) DOOR TYPES F1 F2 2" HEAD 4" HEAD FRAME TYPES LOUVER 1'-4" 10" F NEW FLUSH HOLLOW METAL DOUBLE DOOR DOOR SCHEDULE NO. DOOR FRAME HDW REMARKS WID HT MATL TK TYPE MATL FIN TYPE JAMB 101A 3'- 0" T - 0" EXIST EXIST EXIST EXIST EXIST EXIST EXIST SEE NOTE 1 101B T - 0" T - 0" WD 0'- 1 3/4" A HM P-1/P4 F1 - HW-2 SEE NOTE 5 102 3'-0" 7'- 0" WD 0'- 1 3/4" A HM P-1 F1 - HW-3 - 103 3' - 0" 7'- 0" HM 0'- 1 3/4" F HM P-1 F1 - HW-4 SEE NOTE 3 104 3'- 0" 7' - 0" EXIST EXIST EXIST EXIST EXIST EXIST EXIST SEE NOTE 1 DOOR SCHEDULE NOTES 1. PROVIDE LOCKSET WITH 1 DEADLOCK A/R MS1850S- 1-1/8 2. REPLACE EXISTING LOCKSET WITH 1 ALARM LOCK PRE FL5101ALK501-689 AND INSTALL ONE-WAY VIEWER IVES 698 3. PROVIDE 1'-4"X V-0" LOUVER AT MDF DOORS 4. ADD SIGN ON DOOR "AUTHORIZED PERSONNEL ONLY". 5. PAINT EACH SIDE OF THE DOOR TO MATCH ADJACENT WALL. 6. USE DOOR TYPE F, BUT W/SINGLE DOOR. 7. REPLACE EXISTING LOCKSET WITH 1 BES #1021B-26D41 PUNCH LOCK KEYPAD 8. INSTALL ONE-WAY VIEWER IVES 698, LOOKING OUT FROM INVENTORY ROOM CHANGES IN LEVEL IN EXCESS OF 1/4" AT DOORWAY SHALL BE RAMPED. www.brph.com Copyright © 2014 Architects, Engineers 2727 Paces Ferry Road I Bldg 1 1 Suite 1800 Atlanta I Georgia 1 30339 770-933-9242 1 770-933-9246 f Offices in Melbourne, Orlando, West Palm Beach, Atlanta, Charleston, Seattle These plans are protected by Federal Copyright protection. Unauthorized use may result in an infringement action. ISSUE FOR PERMIT AND CONSTRUCTION REVISION 0 N1 I.L 0- W N Z O V LW/ Of W U) ARCH/ENGR OF RECORD BRUCE A. LOTT AR0012048 DESIGNED BY BDR DRAWN BY KCC CHECKED BY BAL PROJECT NUMBER C06898.057.01 DATE 08/13/14 TmE DOOR SCHEDULES AND HARDWARE DRAWING NO. A8e 1 1 FN 3 n �1 l*J 14 IC A v J N IEw A �! �JA au N ! J Q� oa ii N q6 2 rn� a c(o rn o °D U C N CO (D O c� o � N U CO) U OD ABBREVIATIONS ABBR DESCRIPTION ABBR DESCRIPTION AC AIR CONDITIONER OA OUTSIDE AIR ACT ACOUSTICAL CEILING TILE OAL OUTSIDE AIR LOUVER A/C AIR CONDITIONING OAT OUTSIDE AIR TEMPERATURE AD ACCESS DOOR AFCV AUTOMATIC FLOW CONTROL VALVE OAU OUTSIDE AIR UNIT AFF ABOVE FINISHED FLOOR OC ON CENTER AFG ABOVE FINISHED GRADE OD OUTER DUCT AH AIR HANDLER ODP OPEN DRIP PROOF AHU AIR HANDLING UNIT PD PRESSURE DROP AP ACCESS PANEL PH PHASE ASHRAE AMERICAN SOCIETY OF HEATING, REFRIGERATION, PRV PRESSURE REDUCING VALVE AND AIR CONDITIONING ENGINEERS PSI POUNDS PER SQUARE INCH ASME AMERICAN SOCIETY OF MECHANICAL ENGINEERS PSIG POUNDS PER SQUARE INCH GAUGE BAS BUILDING AUTOMATION SYSTEM RA RETURN AIR BHP BRAKE HORSEPOWER RAT RETURN AIR TEMPERATURE BFP BACKFLOW PREVENTER REF REFRIGERANT BOD BOTTOM OF DUCT REQ REQUIRED BOP BOTTOM OF PIPE RAG RETURN AIR GRILLE BTU BRITISH THERMAL UNIT RH RELATIVE HUMIDITY BTUH BRITISH THERMAL UNIT PER HOUR RLA RATED LOAD AMPS CD CONDENSATE DRAIN RM ROOM CFM CUBIC FEET PER MINUTE CONT CONTINUE RPM REVOLUTION PER MINUTE DAMP DAMPER RTU ROOFTOP UNIT DB DRY BULB SA SUPPLY AIR DG DOOR GRILLE SAG SUPPLY AIR GRILLE DL DOOR LOUVER SAR SUPPLY AIR REGISTER DDC DIRECT DIGITAL CONTROL SAT SUPPLY AIR TEMPERATURE DIA DIAMETER SCFM STANDARD CUBIC FEET PER MINUTE DIFF DIFFERENTIAL SCH SCHEDULE DIV DIVISION SD SUPPLY DIFFUSER DN DOWN SEC SECOND DP DIFFERENTIAL PRESSURE SEER SEASONAL ENERGY EFFICIENCY RATIO DWG DRAWING SEN SENSIBLE DX DIRECT EXPANSION EA EXHAUST AIR SMACNA SHEET METAL AND AIR CONDITIONING EAG EXHAUST AIR GRILLE CONTRACTORS' NATIONAL ASSOCIATION EAR EXHAUST AIR REGISTER SF SUPPLY FAN SP STATIC PRESSURE EAT ENTERING AIR TEMPERATURE SS STAINLESS STEEL EDH ELECTRIC DUCT HEATER TAB TEST ADJUST AND BALANCE ELEC ELECTRIC, ELECTRICAL TAG TRANSFER AIR GRILLE TD TRANSFER DUCT EER ENERGY EFFICIENCY RATIO TEAO TOTALLY ENCLOSED AIR OVER EF EXHAUST FAN TEFC TOTALLY ENCLOSED FAN COOLED EFF EFFICIENCY TEMP TEMPERATURE EQUIP EQUIPMENT TS TEMPERATURE SENSOR ESP EXTERNAL STATIC PRESSURE °F DEGREES FAHRENHEIT TSH TOTAL SENSIBLE HEAT FACP FIRE ALARM CONTROL PANEL TSP TOTAL STATIC PRESSURE FAS FIRE ALARM SYSTEM TSTAT THERMOSTAT FCU FAN COIL UNIT TYP TYPICAL FD FIRE DAMPER TOD TOP OF DUCT FLD FLOOR DRAIN TOS TOP OF STEEL FLEX FLEXIBLE TOT TOTAL FLG FLANGE UH UNIT HEATER FLR FLOOR UL UNDERWRITER'S LABORATORIES UNO UNLESS NOTED OTHERWISE FP FIRE PROTECTION FPM FEET PER MINUTE V VOLTS, VOLTAGE FPS FEET PER SECOND VAC VOLTS ALTERNATING CURRENT FT FEET VAV VARIABLE AIR VOLUME GA GAUGE VFD VARIABLE FREQUENCY DRIVE GALV GALVANIZED W WATT(S) GPM GALLONS PER MINUTE WB WET BULB GWB GYPSUM BOARD H2O WATER WC WATER COLUMN HD HEAD WG WATER GAGE HP HORSEPOWER H/P HEAT PUMP WH WALL HEATER HR HOUR HVAC HEATING, VENTILATION AND AIR CONDITIONING HZ HERTZ ID INSIDE DIMENSION IN INCHES KW KILOWATTS LAT LEAVING AIR TEMPERATURE LOW LIMIT OF WORK LRA LOCKED ROTOR AMPS LVR LOUVER LWT LEAVING WATER TEMPERATURE MAU MAKE-UP AIR UNIT MAX MAXIMUM MAT MIXED AIR TEMPERATURE MBH 1000 BRITISH THERMAL UNITS PER HOUR MCA MINIMUM CIRCUIT AMPACITY MECH MECHANICAL MERV MINIMUM EFFICIENCY REPORTING VALUE MEZZ MEZZANINE MFS MAXIMUM FUSE SIZE MIN MINIMUM MOCP MAXIMUM OVER CURRENT PROTECTION MVD MANUAL VOLUME DAMPER NC NORMALLY CLOSED N/C NOISE CRITERIA NEC NATIONAL ELECTRIC CODE NFPA NATIONAL FIRE PROTECTION ASSOCIATION NIC NOT IN CONTRACT NO NORMALLY OPEN NOM NOMINAL NTE NOT TO EXCEED NTS NOT TO SCALE AIR DISTRIBUTION LEGEND SYMBOL ABBR DESCRIPTION 18x12 RECTANGULAR DUCT SIZE IN INCHES FIRST SIZE LISTED IS SIDE SHOWN. 18x12 � DASH LINE REPRESENT EXISTING DUCT. 18" o ROUND DUCT SIZE IN INCHES SUPPLY AIR DUCT SECTION TURNED UP OR TOWARDS SUPPLY AIR DUCT SECTION TURNED x ` DOWN OR AWAY RETURN AIR DUCT SECTION TURNED T71 UP OR TOWARDS RETURN AIR DUCT SECTION TURNED DOWN OR AWAY EXHAUST AIR DUCT SECTION TURNED UP OR TOWARDS EXHAUST AIR DUCT SECTION TURNED DOWN OR AWAY ROUND DUCT SECTION TURNED UP OR TOWARDS ROUND DUCT SECTION TURNED DOWN OR AWAY END OF DUCT WITH CAP (UNLESS NOTED OTHERWISE) CONCENTRIC DUCT TRANSITION ECCENTRIC DUCT TRANSITION SQUARE TO ROUND TRANSITION GBD GRAVITY BACK DRAFT DAMPER VD MANUAL BALANCING DAMPER FD DUCT FIRE DAMPER WITH ACCESS DOOR INDICATES SUPPLY AIR FLOW DIRECTION INDICATES RETURN OR EXHAUST AIR FLOW DIRECTION CEILING SUPPLY DIFFUSER. REFER TO DIFFUSER AND GRILLE SCHEDULE FOR ADDITIONAL INFORMATION. DASH LINE REPRESENT EXISTING CEILING SUPPLY DIFFUSER. ZCEILING GRILLE (RETURN OR TRANSFER) REFER TO DIFFUSER r 21 AND GRILLE SCHEDULE FOR ADDITIONAL INFORMATION. DASH LINE REPRESENT EXISTING CEILING GRILLE. IL J ® CEILING EXHAUST GRILLE. REFER TO DIFFUSER r 71 AND GRILLE SCHEDULE FOR ADDITIONAL INFORMATION. DASH LINE REPRESENT v/� EXISTING EXHAUST GRILLE. GRILLE, REGISTER OR OPEN DUCT =1 (SUPPLY SHOWN) GENERAL NOTES 1. INSTALL FLEXIBLE DUCTS IN ACCORDANCE WITH SMACNA STANDARDS. 2. FLEXIBLE DUCT RUNOUTS TO ALL DIFFUSERS SHALL BE INSTALLED FREE OF KINKS AND SAGS. LENGTH OF FLEXIBLE RUNOUTS TO AIR REGISTERS SHALL NOT EXCEED 6 FEET. SUPPORT FLEXIBLE DUCTS IN ACCORDANCE WITH THE SMACNA STANDARD. 3. PROVIDE MANUAL VOLUME DAMPERS AT EACH DUCT BRANCH LEADING TO AN OUTLET/INLET OPENING. INSTALL THESE DAMPERS AS FAR AS POSSIBLE AWAY FROM THE OPENING. 4. DUCT PRESSURE AND SEAL CLASSIFICATION SHALL BE AS INDICATED ON THE DRAWINGS. IF NOT INDICATED, IT SHALL BE AS FOLLOWS: SUPPLY DUCTS: 2" POSITIVE; SEAL CLASS B EXHAUST DUCTS: 2" NEGATIVE; SEAL CLASS C RETURN DUCTS: 2" NEGATIVE; SEAL CLASS C EXHAUST DUCT FAN DISCHARGE: 2" POSITIVE, SEAL CLASS A 5. COMPLY WITH ALL APPLICABLE LOCAUSTATE BUILDING CODES FOR ALL WORK UNDER THIS CONTRACT. 6. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT LOCATION OF CEILING DIFFUSERS/GRILLES. 7. COORDINATE ALL MECHANICAL WORK & EQUIPMENT WITH STRUCTURAL MEMBERS, ELECTRICAL WORK AND FIXTURES, AND ALL OTHER TRADES. 8. VERIFY REFLECTED CEILING PLANS IN THE FIELD FOR EXACT LAYOUT LOCATION OF ALL CEILING GRILLES & DIFFUSERS, COORDINATE WITH ALL OTHER TRADES FOR THEIR LAYOUTS. 9• PROVIDE ACCESS DOORS IN INACCESSIBLE CEILINGS TO ACCESS MEP DEVICES ABOVE CEILINGS NOT OTHERWISE ACCESSIBLE. 10. FABRICATE ALL DUCT WORK IN ACCORDANCE WITH SMACNA STANDARDS. 11. PROVIDE INSULATED TRAPPED CONDENSATION DRAIN PIPING, WITH AIR GAPS, FROM COOLING COIL DRAIN PANS, TO NEAREST FLOOR DRAIN OR CONDENSATE DRAIN STORM DRAIN OR AS SHOWN ON PLANS 12. PROVIDE DUCT FLEXIBLE CONNECTOR BETWEEN EACH DUCT & THE FAN THAT IT IS CONNECTED TO. 13. PROVIDE ALL HVAC EQUIPMENT COMPLETE WITH MOTOR STARTERS OR VFDs AS PER MANUFACTURER REQUIREMENT. 14. DETERMINE FINAL LOCATIONS & ORIENTATION OF ALL EQUIPMENT IN THE FIELD. 15. LOCATE ALL PIPING AND DUCTWORK ABOVE ACCESSIBLE CEILINGS UNLESS OTHERWISE NOTED. TO ALLOW ACCESS AND MAINTENANCE, DO NOT LOCATE DUCT, PIPING AND EQUIPMENT SUCH THAT ACCESS IS UNACCEPTABLE FOR FACILITIES MAINTENANCE AND REPAIR. 16. MOUNT THERMOSTATS AND SENSORS AS INDICATED ON PLANS 48" A.F.F. FOR ADA "FRONT ACCESS" UNLESS OTHERWISE REQUIRED BY OWNER OR ARCHITECT. COORDINATE LOCATIONS WITH CABINETRY, ELECTRICAL SWITCHES, ETC. DO NOT MOUNT THEM ABOVE ELECTRICAL DEVICES. PROVIDE AN INSULATED SUB -BASE FOR ANY THERMOSTAT MOUNTED ON A WALL ADJACENT TO AN UNCONDITIONED SPACE. GENERAL LEGEND SYMBOL DESCRIPTION DETAIL SYMBOL: A A = IDENTIFYING NUMBER B B = SHEET WHERE DETAIL IS SHOWN SECTION SYMBOL: A A = IDENTIFYING LETTER g B = SHEET WHERE SECTION IS SHOWN ELEVATION SYMBOL: A A = IDENTIFYING LETTER B B = SHEET WHERE SECTION IS SHOWN TITLE SYMBOL ON SHEET WHERE A SHOWN: A = IDENTIFYING NUMBER/LETTER B B = SHEET WHERE SECTION IS FROM SF-1 800 TYPE - SEE SCHEDULE ON SHEET �M-601 FOR TYPE AND SIZE A...•••2llllll -*--QUANTITY (1 IF BLANK) 100 -CFM PER DEVICE FOR SIZING (REFER TO FLOW DIAGRAMS FOR ACTUAL AIRFLOW REQUIREMENTS) ��QAQ� /• � 23-# T'STAT / TS e EQUIPMENT IDENTIFICATION (REFER TO SCHEDULES) CFM AIR DISTRIBUTION DEVICE REVISION CLOUD AND REVISION NUMBER SPECIFIC NOTES THERMOSTAT / TEMPERATURE SENSOR (WALL MOUNTED) DASHED LINE INDICATES CONTROLLED DEVICE CONNECT TO EXISTING PIPING LEGEND SYMBOL ABBR DESCRIPTION LINEWORK INDICATES NEW PIPING OR EQUIPMENT SAN SANITARY DRAIN PIPING D D DRAIN - INDIRECT CD CD CONDENSATE DRAIN - INDIRECT J CAP PIPE END CAP D PIPE TURNING DOWN OR AWAY — 0 PIPE TURNING UP OR TOWARD - PIPE TURNING DOWN OR AWAY (TEE) REDUCER (NOT TYPICALLY SHOWN) PIPE CONNECTION PIPE ANCHOR PIPE SLEEVE or ALIGNMENT GUIDES 17 DRAWINGS ARE DIAGRAMMATIC. CONTRACTOR SHALL COORDINATE EXACT LOCATIONS AND ELEVATIONS OF ALL DUCTWORK, PIPING, LIGHTS, CONDUIT, CABLE TRAYS, ETC., PRIOR TO INSTALLATION. OFFSET DUCT WHERE REQUIRED TO AVOID INTERFERENCE. THE CONTRACTOR SHALL PROVIDE ALL SIZES, MATERIALS, AND RATINGS BEFORE ORDERING OR FABRICATION OF ANY PRODUCT 18. DO NOT LOCATE VALVES, DAMPERS, ACTUATORS, CONTROL COMPONENTS, ANY EQUIPMENT WITH MOVING PARTS OR ANY EQUIPMENT NEEDING ACCESS OR REGULAR MAINTENANCE ABOVE INACCESSIBLE CEILINGS. OBTAIN PRIOR APPROVAL IF UNAVOIDABLE AND PROVIDE AN ACCESS PANEL THAT WILL ALLOW SAFE AND PRACTICAL ACCESS. 19. THE CONTRACTOR SHALL VERIFY ELECTRICAL POWER AND CONTROL VOLTAGE AND PHASE FOR EACH PIECE OF EQUIPMENT PRIOR TO BID AND BEFORE ORDERING ANY ELECTRICALLY OPERATED EQUIPMENT. 20. ALL ELECTRICAL WIRING IN CEILING PLENUMS SHALL BE PLENUM RATED CABLE OR RUN IN CONDUIT. 21. ALL DUCT DIMENSIONS ARE INSIDE CLEAR DIMENSIONS AND DO NOT INCLUDE ALLOWANCES FOR DUCT LINER THICKNESS. 22. ROUTE DUCTWORK BETWEEN BEAMS TIGHT TO BOTTOM OF STRUCTURE. PROVIDE DUCT OFFSETS OVER OR UNDER PIPING OR OBSTRUCTIONS AS REQUIRED. WHERE DUCT OFFSETS ARE REQUIRED, USE 45' SMOOTH RADIUS ELBOWS OR MITERED ELBOW WITH TURNING VANES WHERE SPACE IS RESTRICTED. 23• TRANSITION RECTANGULAR DUCTWORK ON THE BOTTOM AND THE SIDES. MAINTAIN DUCTWORK LEVEL AS HIGH AS POSSIBLE UNLESS NOTED OTHERWISE. 24• ALL OPEN END DUCTS SHALL BE REINFORCED WITH 1-1/2" x 1-1/2" x 1/8" GALVANIZED STEEL ANGLES BOLTED OR RIVETED 6" ON CENTER ALL AROUND THE EXTERIOR OF THE DUCT. 25. PROVIDE IDENTIFICATION FOR ALL ABOVE CEILING MECHANICAL DAMPERS, EQUIPMENT AND OTHER APPURTENANCES REQUIRING ACCESS BY APPROVED UNOBTRUSIVE TAGS ATTACHED TO THE CEILING GRID. 26. PROVIDE RETURN AIR GRILLES FOR ALL SPACES THAT ARE PROVIDED WITH SUPPLY AIR AND/OR OUTSIDE AIR. PROVIDE AIR TRANSFER OPENINGS ABOVE CEILINGS FOR RETURN AIR FROM ALL AREAS BOUNDED BY FULL HEIGHT PARTITIONS; PROVIDE WITH FIRE DAMPER WHERE RATED WALLS REQUIRE THEM. ENSURE CONTINUOUS ADEQUATELY SIZED PATH FOR RETURN AIR TO GET BACK, ABOVE THE CEILING TO THE ASSOCIATED RETURN AIR DUCTS, OR SYSTEM. 27. ACOUSTICALLY LINE ALL TRANSFER DUCTS AND PROVIDE WITH 90' ELBOWS SIZED SAME AS DUCT. 28. THE METHOD OF FIXING THE UPPER ATTACHMENTS FOR PIPE AND DUCT SUPPORTS SHALL BE TO THE APPROVAL OF THE STRUCTURAL ENGINEER OF RECORD. www.brph.com Copyright © 2014 Architects, Engineers 2727 Paces Ferry Road I Bldg 1 1 Suite 1800 Atlanta I Georgia 1 30339 770-933-9242 1 770-933-9246 f Offices in Melbourne, Orlando, West Palm Beach, Atlanta, Charleston, Seattle These plans are protected by Federal Copyright protection. Unauthorized use may result in an infringement action. ISSUE FOR PERMIT AND CONSTRUCTION REVISION z�, r 11 Ln M M _! J LL (f� J Z 0 O = = w W N 06 0 W `+ U) Q W m N J Q r R � * S No. 373/6 1 * _ PROEEESSIONAE i \ ARCH/ENGR OF RECORD BEN TRANWICK FL PE 37376 DESIGNED BY CEJ DRAWN BY CEJ CHECKED BY JST PROJECT NUMBER C06898.057.00 DATE 05/22/14 TITLE MECHANICAL LEGEND AND ABBREVATIONS DRAWING NO. E BJ 50 �o Cm LJL Ui = - U LW � �I DJAaLL N J I- J co X Q � l:w o nl 00Lr) a OD0) CS U w N � N O c� o U a N a U co DIVISION 23 PART 1 - GENERAL 1.01 GENERAL MECHANICAL REQUIREMENTS DRAWINGS AND GENERAL CONDITIONS OF CONTRACT PROVIDED BY THE OWNER, INCLUDING GENERAL AND SUPPLEMENTAL CONDITIONS AND SPECIFICATIONS, APPLY TO WORK SPECIFIED IN THIS SECTION. 1.02 CODES AND STANDARDS: THE ENTIRE SYSTEM AND ALL COMPONENTS LISTED HEREIN SHALL MEET ALL STATE, COUNTY, AND LOCAL CODES AND ORDINANCES IN EVERY RESPECT. 1.03 SCOPE OF WORK: MECHANICAL WORK SHALL INCLUDE - BUT IS NOT LIMITED TO - LABOR, MATERIALS, SERVICES, EQUIPMENT AND APPLIANCES REQUIRED FOR NEW WORK AND MODIFICATIONS TO EXISTING HEATING, VENTILATING AND AIR CONDITIONING SYSTEMS, INCLUDING REPLACEMENT OF DUCTWORK, DIFFUSERS, PIPING AND TEMPERATURE CONTROLS. 1. MODIFY THE EXISTING HVAC AIR DISTRIBUTION SYSTEM TO COORDINATE WITH ARCHITECTURAL BUILDING INTERIOR MODIFICATIONS DESCRIBED ON THE DRAWINGS, INCLUDING PROVISIONS OF NEW DUCTWORK, INSULATION, ACCESSORIES AND HANGER MATERIALS, DIFFUSERS AND GRILLES. 2. TEST ADJUST AND BALANCE HVAC SYSTEMS WITHIN THE SCOPE OF WORK. REFER TO SECTION 1.08. 3. PROVIDE NEW THERMOSTATS OR TEMPERATURE SENSORS. 4. PROVIDE ALL CONNECTING PIPING, DUCTWORK, DIFFUSERS AND GRILLES; COORDINATE INSTALLATION OF HVAC WORK WITH ALL OTHER TRADES DESCRIBED BY THE PROJECT CONSTRUCTION DOCUMENTS, IN PARTICULAR, ALL WORK ABOVE NEW AND EXISTING SUSPENDED CEILINGS, INCLUDING: 1. ELECTRICAL MODIFICATIONS TO LIGHTING, POWER AND SYSTEMS PROVIDED UNDER DIVISION 26, INCLUDING SECURITY AND FIRE ALARM SYSTEMS; 2. EXISTING PLUMBING AND HVAC PIPING SYSTEMS; 3. ARCHITECTURAL AND STRUCTURAL MODIFICATIONS - WALLS AND UNCLASSIFIED INTERIOR PARTITIONS. 1.04 PERMITS AND INSPECTIONS: THE CONTRACTOR SHALL OBTAIN ALL REQUIRED PERMITS, INSPECTIONS AND PAY ALL FEES. 1.05 PRODUCTS: ALL EQUIPMENT AND APPURTENANCES SHOWN ON THE DRAWINGS AND/OR INDICATED IN THESE SPECIFICATIONS SHALL BE NEW, UNLESS OTHERWISE NOTED, AND FREE OF DEFECTS. ALL ELECTRICAL POWERED EQUIPMENT SHALL BE U.L. OR E.T.L. LISTED. 1.06 SUBSTITUTIONS: EQUIPMENT AND WORK DESCRIBED ON THE DESIGN DRAWINGS AND WITHIN THESE SPECIFICATIONS ARE THE BASIS OF DESIGN AND "SPECIFIED STANDARD" OF QUALITY. NO SUBSTITUTIONS SHALL BE MADE WITHOUT PRIOR WRITTEN APPROVAL OF THE ENGINEER/OWNER. THE ELECTRICAL REQUIREMENTS SHALL BE COORDINATED BY THE MECHANICAL CONTRACTOR AND EQUIPMENT VENDOR WITH THE ELECTRICAL CONTRACTOR PRIOR TO SUBMITTING BIDS. FAILURE OF THE MECHANICAL CONTRACTOR AND THE VENDOR TO DO SO WILL NOT BE CAUSE FOR A CHANGE OF BID AT A LATER TIME. IT WILL NOT BE THE ELECTRICIAN'S RESPONSIBILITY TO COORDINATE REVISED ELECTRICAL REQUIREMENTS DUE TO EQUIPMENT CHANGES INITIATED BY THE MECHANICAL CONTRACTOR AND VENDOR. IN ADDITION, THE MECHANICAL CONTRACTOR SHALL BE FINANCIALLY RESPONSIBLE FOR ANY AND ALL CHANGES TO ENGINEERING PLANS REQUIRED BY THE AUTHORITY HAVING JURISDICTION. 1.07 SHOP DRAWINGS AND SUBMITTALS: SUBMIT FOR ENGINEER'S APPROVAL, SHOP DRAWINGS AND MANUFACTURER'S DATA, IN ELECTRONIC FORMAT FOR ALL NEW EQUIPMENT AND ACCESSORIES PRIOR TO PURCHASE AND OR FABRICATION. SHOP DRAWINGS FOR EQUIPMENT REQUIRING ELECTRICAL POWER OR CONTROL WIRING CONNECTIONS SHALL INCLUDE COMPLETE WIRING DIAGRAMS. 1.08 SUBCONTRACT FOR CERTIFIED TEST AND BALANCE: SUBMIT QUALIFICATIONS AND CERTIFICATIONS OF THE PROPOSED TEST AND BALANCE SUBCONTRACTOR. THE SUBCONTRACTOR MUST BE CERTIFIED BY THE ASSOCIATED AIR BALANCE COUNCIL OR NATIONAL ENVIRONMENTAL BALANCING BUREAU. SUBMITTAL OF MULTIPLE TEST ADJUST AND BALANCE CONTRACTORS IS ACCEPTABLE FOR COMPETITIVE BIDDING OF WORK. 1.09 RELATED WORK SPECIFIED ELSEWHERE REFER TO ELECTRICAL SPECIFICATION (DIV. 26) FOR ELECTRICAL WORK TO BE DONE IN CONJUNCTION WITH THE MECHANICAL WORK. THIS CONTRACTOR IS RESPONSIBLE FOR ALL CONDUIT, WIRING, JUNCTION BOXES, ETC., REQUIRED FOR HVAC CONTROLS. INSTALL DUCT SMOKE DETECTOR FURNISHED BY DIVISION 26 IN SUPPLY AIR DUCTS OF AIR HANDLING UNITS EXCEEDING 2,000CFM AND WHERE INDICATED ON DRAWINGS. DETECTOR TO SHUT UNIT DOWN WHEN ACTIVATED. 1.10 WORKMANSHIP ALL MATERIALS SHALL BE FABRICATED AND INSTALLED IN A NEAT AND WORKMANLIKE MANNER WITH THE COORDINATION OF ALL INVOLVED TRADES TO AVOID INTERFERENCES AND DELAY DUE TO LACK OF COORDINATION. NO ALLOWANCES WILL BE MADE FOR REWORK DUE TO COORDINATION DIFFICULTIES OR INTERFERENCES BETWEEN INVOLVED TRADES. 1.11 AS-BUILTS CONTRACTOR SHALL PROVIDE THE ENGINEER TWO (2) SETS OF COMPLETE HVAC AS -BUILT DRAWINGS AT THE TIME OF SUBSTANTIAL COMPLETION. AS-BUILTS SHALL BE PROVIDED IN HARD COPY AND AUTOCAD DRAWING FILES [RELEASE 2014 OR PRIOR]. AS -BUILT DRAWINGS SHALL CONSIST OF AN ACCURATE "AS - BUILT" RECORD OF THE INSTALLED WORK. PROJECT WILL NOT BE COMPLETE UNTIL ACCURATE AS-BUILTS ARE DELIVERED. PART 2 MECHANICAL TECHNICAL SPECIFICATIONS: 2.01 GENERAL THE CONTRACTOR SHALL PROVIDE ALL HVAC EQUIPMENT AND MATERIALS TO ACCOMPLISH THE WORK DESCRIBED ON THESE DRAWINGS UNLESS OTHERWISE NOTED. INSPECT ALL CONSTRUCTION MATERIALS PRIOR TO FABRICATION OR INSTALLATION. REJECT MATERIALS FOUND TO BE DAMAGED OR SUB -STANDARD QUALITY. 2.02 GRILLES, REGISTERS AND DIFFUSERS: ALUMINUM CONSTRUCTION WITH WHITE BAKED ENAMEL FINISH, AS SCHEDULED ON THE DRAWINGS, NECK SIZES COORDINATED WITH AIR FLOW RANGES LISTED. AIR FLOW REQUIRED SHALL NOT EXCEED THE SCHEDULED NC RATING AS DEFINED IN THE LATEST AMERICAN SOCIETY OF HEATING, REFRIGERATING AND AIR CONDITIONING ENGINEERS GUIDE. MANUFACTURED PRODUCTS OF TITUS, HART & COOLEY, PRICE, METAL-AIRE OR ALTERNATES MAY BE FURNISHED, SUBJECT TO SUBMITTAL REVIEW BY THE OWNER'S ENGINEER. 2.03 FLEXIBLE DUCT: FLEXIBLE DUCTWORK SHALL BE ACOUSTICAL LOW PRESSURE TYPE WITH INTERIOR LINER, METAL HELIX, FIBERGLASS INSULATION WITH AN R-VALUE OF 6.0 OR GREATER, AND COPOLYMER SEAMLESS OUTSIDE SLEEVE. THE ENTIRE FLEXIBLE DUCT ASSEMBLY SHALL BE LISTED IN ACCORDANCE WITH UL-181 CLASS 1 AIR DUCT MATERIAL. THE MAXIMUM LENGTH OF ANY FLEX DUCT SHALL BE 6-0". FLEXIBLE DUCTWORK SHALL MEET ASHRAE 90.1 ENERGY EFFICIENCY CODE. ALL JOINTS AT CONNECTIONS TO DIFFUSERS AND DUCTWORK SHALL BE SEALED WITH GLASS FABRIC AND MASTIC. 2.04 SHEET METAL DUCTWORK: PROVIDE MATERIALS COMPATIBLE WITH EXISTING DUCTWORK CONSTRUCTION. ALL DUCT SIZES NOTED REFER TO INSIDE DIMENSIONS. ANY CHANGES IN THE GEOMETRY OF THE DUCTWORK MUST BE SUBMITTED FOR OWNER'S APPROVAL BEFORE FABRICATION. MATERIALS: GALVANIZED STEEL (G-90) OF GAUGES CONFORMING TO LATEST EDITION OF SMACNA STANDARDS BASED ON THE FOLLOWING PRESSURE UNLESS SPECIFICALLY NOTED OTHERWISE ON THE DRAWINGS. SUPPLY AIR: 2" W.G. POSITIVE PRESSURE; SEAL CLASS B RETURN AIR: 2" W.G. NEGATIVE PRESSURE; SEAL CLASS C EXHAUST AIR: 2" W.G. NEGATIVE PRESSURE; SEAL CLASS C EXHAUST DUCT FROM FAN DISCHARGE: 2" POSITIVE, SEAL CLASS A PROVIDE ADJUSTABLE VOLUME DAMPERS WITH LOCKING QUADRANTS AT BRANCH CONNECTIONS, ACCESSIBLE FOR EASE OF OPERATION. ELBOWS OR CHANGES IN DUCT DIRECTION GREATER THAN 45 DEGREES SHALL BE FITTED WITH AIR TURNS CONSISTING OF CURVED AIRFOIL BLADES OR VANES WHICH WILL PERMIT THE AIR TO MAKE ABRUPT TURNS WITHOUT APPRECIABLE TURBULENCE. ALL JOINTS AT CONNECTIONS TO DIFFUSERS AND DUCTWORK SHALL BE SEALED WITH GLASS FABRIC AND MASTIC. PROVIDE FLEXIBLE CONNECTORS AT DUCT CONNECTIONS TO FANS, CONSISTING OF WATER -PROOF, UV -RESISTANT HEAVY CANVAS OR NEOPRENE FABRIC WITH AIR -TIGHT SEAMS. 2.05 DUCTWORK INSULATION: MATERIALS SHALL BE AS MANUFACTURED BY CERTAINTEED, OWENS-CORNING, MANVILLE, PITTSBURGH CORNING, ARMSTRONG, OR APPROVED EQUAL. INSULATION SUNDRIES AND ADHESIVES SHALL BE AS MANUFACTURED BY BENJAMIN FOSTER, CHILDERS, VIMASCO, OR APPROVED EQUAL. INSULATE ALL SHEETMETAL DUCTWORK EXTERNALLY WITH MANVILLE R SERIES MICROLITE TYPE 75 OR 100 INSULATION OR APPROVED EQUAL. INSULATION SHALL HAVE TYPE II FSK FACING AND UL FIRE HAZARD CLASSIFICATION OF: FLAME SPREAD 25, SMOKE DEVELOPED 50, FUEL CONTRIBUTED 50. INSTALL INSULATION PER SMACNA AND MANUFACTURER'S RECOMMENDATIONS. ALL INSULATION JOINTS SHALL BE SEALED WITH GLASS FABRIC AND MASTIC. SUPPLY DUCTWORK, CONCEALED OR EXPOSED, IN CONDITIONED INTERIOR SPACE: MINIMUM INSULATION THICKNESS SHALL BE 1.0" (R-4.2 MIN.) 2.06 ACCESS DOORS FURNISH IN DUCTWORK AS INDICATED AS WHEREVER NECESSARY FOR PROPER ACCESS TO ALL INSTRUMENTS, CONTROLS, FIRE DAMPERS, MOTORIZED DAMPERS, VOLUME DAMPERS, AND EQUIPMENT AND FOR CONVENIENT INSPECTION, MAINTENANCE AND REPLACEMENT OF SAME. SIZE TO BE AMPLE FOR USAGE. OPENINGS TO BE REINFORCED ON ALL SIDES WITH MATERIAL OR DUCTWORK IN WHICH DOORS ARE INSTALLED.. 2.07 HVAC CONTROLS PROVIDE A COMPLETE LOCAL CONTROL SYSTEM INCLUDING ALL WIRING, CONTROLS AND BOXES. ALL ELECTRONIC COMPONENTS SHALL BE DESIGNED SPECIFICALLY FOR ITS INTENDED FUNCTION IN THIS SYSTEM. THE SYSTEM SHALL BE CAPABLE OF EITHER MANUAL OR AUTOMATIC HEATING/COOLING CHANGEOVER CONTROL. THE SYSTEM SHALL CONTROL SPACE TEMPERATURE SET POINTS BY STARTING/STOPPING DX SPLIT -SYSTEM OPERATION. THE SYSTEM WILL INCORPORATE A SPACE THERMOSTAT WITH ADJUSTABLE SET POINTS AND MANUAL OVERRIDE TO TURN THE SYSTEM "ON" FOR A PREDETERMINED PERIOD. NOTE: CONTRACTOR SHALL HAVE THE TEST ADJUST AND BALANCE CONTRACTOR PRESENT FOR STARTUP OF SYSTEM. PROVIDE DOCUMENT ON FACTORY REPRESENTATIVES LETTERHEAD INDICATING THAT SYSTEM HAS BEEN PROPERLY CALIBRATED, TESTED, AND SETUP. PROVIDE A MINIMUM OF 4 HOURS TRAINING FOR THE OWNER'S REPRESENTATIVE 2.08 ELECTRICAL PROVIDE ALL 120 VOLT AND 24 VOLT WIRING BETWEEN CONTROL DEVICES AS NECESSARY TO MAKE COMPLETE AND OPERATIONAL SYSTEM. PROVIDE 120/24 VAC TRANSFORMERS AS REQUIRED. COORDINATE WITH DIVISION 26 FOR 120V POWER ROUGH -IN, CONTROL POWER AND WIRING. 24 VOLT WIRING SHALL BE PLENUM RATED CABLE. PART 3 - EXECUTION 3.01 GENERAL REQUIREMENTS REFER TO AND COMPLY WITH OWNER'S GENERAL REQUIREMENTS CONSTRUCTION, INCLUDING: BUILDING SECURITY, PROPER IDENTIFICATION OF ALL WORKERS PRIOR TO COMMENCEMENT OF WORK TO OBTAIN REQUIRED BADGING. SCHEDULING OF WORK WITH THE OWNER TO MINIMIZE DISRUPTIONS TO THE NORMAL OPERATIONS IN THE BUILDING. MAINTENANCE OF A CLEAN, SAFE WORK ENVIRONMENT THROUGHOUT CONSTRUCTION, INCLUDING DAILY CLEANUP OF DESIGNATED WORK AREAS AND REMOVAL OF DEBRIS FROM THE BUILDING. SAFETY, INCLUDING PROVISION OF APPROVED PORTABLE FIRE EXTINGUISHER(S), HOT WORK PERMITS IN ADVANCE OF WELDING OR OTHER ACTIVITIES AS NECESSARY. THE DRAWINGS ARE DIAGRAMMATIC WITH RESPECT TO EQUIPMENT LOCATIONS AND EXISTING CONDITIONS AND SHALL BE FOLLOWED AS CLOSELY AS POSSIBLE, SUBJECT TO BUILDING CONSTRUCTION AND INTERFERENCES WITH OTHER TRADES. 3.02 LAYOUT AND FABRICATION ALL WORK SHALL BE INSTALLED TO INSURE MAXIMUM HEADROOM, BALANCED OPERATION AND SUITABLE AESTHETIC APPEARANCE. PROVIDE FIELD MEASUREMENTS REQUIRED TO GUARANTEE AN APPROVED AND FUNCTIONAL INSTALLATION. COORDINATE WORK WITH ALL TRADES TO AVOID INTERFERENCES OR DELAYS. NO ALLOWANCES WILL BE MADE FOR REWORK DUE TO LACK OF COORDINATION OR INTERFERENCES BETWEEN INVOLVED TRADES. FIELD VERIFY EXISTING CONDITIONS FOR EXACT LOCATION AND ROUTING OF SYSTEMS. PROVIDE OFFSETS, TRANSITIONS AND ADAPTORS AS REQUIRED. COORDINATE WITH OTHER TRADES AND FIELD VERIFY EXISTING CONDITIONS FOR EXACT LOCATION AND ROUTING OF SYSTEMS. PROVIDE OFFSETS, TRANSITIONS AND ADAPTORS AS REQUIRED. NOT ALL COMPONENTS REQUIRED FOR A COMPLETE INSTALLATION ARE SHOWN ON THESE DRAWINGS. REFER TO EQUIPMENT INSTALLATION INSTRUCTION, SCHEDULES AND APPLICABLE CODES FOR ADDITIONAL INFORMATION, INCLUDING REQUIRED CONNECTION LOCATIONS, TYPES AND SIZES. PROVIDE ISOLATION VALVES AND UNIONS AT ALL EQUIPMENT AND AS INDICATED ON DRAWINGS. CONTRACTOR SHALL BE RESPONSIBLE FOR FURNISHING AND INSTALLING ADEQUATE AND PROPER INSULATION AND MOISTURE -SEAL IN A MANNER THAT WILL PERMANENTLY PREVENT THE ACCUMULATION OF ANY OBJECTIONABLE MOISTURE ON THE EXTERIOR OF AIR-CONDITIONING UNITS, REFRIGERANT -PIPING, CONDENSATE DRAIN PIPING, AIR DUCTS OR OTHER PARTS OF THE SYSTEM. THE CONTRACTOR SHALL CORRECT THE CAUSE OF ANY CONDENSATION AND FULLY REPAIR, WITHOUT COST TO THE OWNER, ANY DAMAGES TO BUILDING SURFACES, FURNISHINGS OR EQUIPMENT CAUSED BY CONDENSATION FROM THIS SYSTEM, FOR THE FULL PERIOD OF THE GUARANTEE. FABRICATE AND INSTALL MECHANICAL WORK IN A NEAT AND WORKMAN -LIKE MANNER. THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR TEARING -OUT AND REPLACEMENT OF ANY WORK OF SUB -STANDARD QUALITY. PERFORM ALL WORK NECESSARY TO PREPARE THE STRUCTURE FOR THE INSTALLATION OF THE WORK. ALL HOLES, OPENINGS AND DAMAGED MATERIALS CREATED DURING CONSTRUCTION SHALL BE REPAIRED AND FINISHED TO MATCH ADJACENT SURFACES. 3.03 DUCTWORK FABRICATION AND INSTALLATION VERIFY SIZES, ELEVATIONS AND CONFIGURATION OF EXISTING DUCTWORK BEFORE REMOVAL OF ANY INSTALLED MATERIALS AND BEFORE FABRICATION OF NEW WORK. PROTECT BOTH NEWLY -INSTALLED MATERIALS AND EXISTING SYSTEMS FROM DAMAGE THROUGH COMPLETION OF CONSTRUCTION. RIGID AND FLEXIBLE DUCT BRANCHES SHALL BE INSTALLED WITHOUT RESTRICTION OF THE AIRSTREAM. 3.04 HVAC INSTALLATION NOT ALL COMPONENTS REQUIRED FOR A COMPLETE INSTALLATION ARE SHOWN ON THESE DRAWINGS. FURNISH AND INSTALL PER MANUFACTURER'S INSTALLATION/OPERATION/MAINTENANCE, APPLICABLE CODES AND DETAILS, INCLUDING REQUIRED CONNECTION LOCATIONS, TYPES AND SIZES. INSPECT ALL COMPONENTS PRIOR TO INSTALLATION AND DETERMINE THAT ALL COMPONENTS HAVE BEEN RECEIVED IN GOOD CONDITION. PROVIDE FOR PROPER HANDLING AND INSTALLATION AND ENSURE EQUIPMENT IS NOT DAMAGED PRIOR TO, OR DURING, INSTALLATION. PROVIDE HANGERS, HARDWARE AND MATERIALS NECESSARY FOR PROPER INSTALLATION, INCLUDING VIBRATION ISOLATION, SHIM STOCK, ANCHOR BOLTS, SEALANTS, WHETHER NOTED ON THE DRAWINGS OR DESCRIBED IN THE MANUFACTURER'S DOCUMENTATION. SUPPORT CONNECTING DUCTWORK INDEPENDENTLY FROM EQUIPMENT CONNECTIONS TO ENABLE SERVICE WITHOUT DISTURBING DUCTWORK, DIFFUSERS, ETC.. 3.05 HVAC CONTROLS PROVIDE WIRING AND HARDWARE FOR ALL NEW CONTROLS AS REQUIRED. 3.06 SYSTEM IDENTIFICATION PROVIDE NEW IDENTIFICATION LABELS ON OR NEAR EACH PIECE OF HVAC EQUIPMENT, OPERATIONAL DEVICE AND ELECTRICAL DISCONNECT. EQUIPMENT LABELS SHALL MATCH EXISTING IDENTIFICATION, INCLUDING SIGNS OR PLASTIC EQUIPMENT MARKERS PERMANENTLY SECURED TO EQUIPMENT. THE LETTERING SHALL BE ENGRAVED. ALL VALVES SHALL BE TAGGED USING PLASTIC LAMINATE TAGS AND SECURED WITH BRASS CHAINS. THE TAGS SHALL INDICATE THE VALVE SIZE, SERVICE AND FUNCTION (IE. 2" CW., MAIN SERVICE SHUTOFF). 3.07 HVAC TESTING, ADJUSTING & BALANCING ADJUST SUPPLY DIFFUSERS TO DELIVER NOT LESS THAN THE REQUIRED AIR QUANTITY. AIR FLOWS EXCEEDING SPECIFIED QUANTITIES SHALL BE SUBJECT TO THE APPROVAL OF THE ENGINEER IF FOUND NOT TO HAVE OBJECTIONABLE EFFECTS SUCH AS NOISE, DRAFTS, OR MOTOR OVERLOAD. THE TESTING, ADJUSTING AND BALANCING SUBCONTRACTOR (QUALIFIED BY PRIOR APPROVAL THROUGH THE ENGINEER) SHALL PREPARE AND SUBMIT A TEST, ADJUST AND BALANCE REPORT IN THE ELECTRONIC FORMAT REQUIRED BY THE OWNER. SUBMIT TAB REPORT TO THE ENGINEER AT TIME OF SUBSTANTIAL COMPLETION INSPECTION, TO CONTAIN THE FOLLOWING DATA: THE TEST, ADJUST AND BALANCE REPORT SHALL BE TYPE WRITTEN AND CONTAIN THE FOLLOWING DATA: 1. DATE, TIME, WEATHER, WHEN TEST TAKEN. 2. AIR CAPACITIES AT EACH UNIT INCLUDING OUTSIDE AIR. (ENTERING AND LEAVING DB/WB) (IF APPLICABLE) 3. STATIC PRESSURE THROUGH UNITS AND UNIT COMPONENTS. 4. MOTOR OPERATING VOLTAGE AND AMPERAGE. (IF APPLICABLE) 5. DRIVE TYPES, SIZES AND SPEED RANGE. (IF APPLICABLE) 6. IDENTIFICATION OF ALL AIR TERMINAL DEVICES WITH DESIGN CFM AND ACTUAL CFM. ADDITIONALLY, SYSTEMS DRAWINGS CLEARLY MARKED TO IDENTIFY LOCATION OF EQUIPMENT AND AIR DEVICES TESTED SHALL BE PROVIDED ALONG WITH THE WRITTEN TEST AND BALANCE REPORT. COORDINATE TESTING AND BALANCING REQUIREMENTS WITH THE OWNER'S REPRESENTATIVE FOR RE- START OF ALL AFFECTED HVAC SYSTEMS, INCLUDING NEW EQUIPMENT AND CONTROLS. PROVIDE DOCUMENTS ON CONTRACTOR'S LETTERHEAD INDICATING THAT EACH SYSTEM HAS BEEN PROPERLY CALIBRATED, TESTED AND SETUP. 3.08 MAINTENANCE MANUALS/AS-BUILT DRAWINGS PROVIDE COMPLETE MAINTENANCE MANUALS (3 REQUIRED) ON ALL NEW EQUIPMENT. ORGANIZE OPERATING AND MAINTENANCE DATA INTO SUITABLE SETS OF MANAGEABLE SIZE. BIND PROPERLY INDEXED DATA IN INDIVIDUAL, HEAVY-DUTY, 2-INCH, 3-RING VINYL -COVERED BINDERS WITH POCKET FOLDERS FOR FOLDED SHEET INFORMATION. MARK APPROPRIATE IDENTIFICATION ON FRONT AND SPINE OF EACH BINDER. INCLUDE THE FOLLOWING TYPES OF INFORMATION -THE INFORMATION WILL BE TURNED OVER TO THE OWNER AT TIME OF SUBSTANTIAL COMPLETION: OPERATING AND MAINTENANCE INSTRUCTIONS SPARE PARTS LIST COPIES OF WARRANTIES WIRING DIAGRAMS INSPECTION REPORTS & APPROVALS SHOP DRAWINGS AND PRODUCT DATA TEST AND BALANCE INFORMATION 3.09 WARRANTY/GUARANTEE THE CONTRACTOR SHALL WARRANTY/GUARANTEE AND MAINTAIN THE WORK AND MATERIALS AND KEEP SAME IN PERFECT REPAIR AND CONDITION FOR A PERIOD OF ONE (1) YEAR. DEFECTS OF ANY KIND DUE TO FAULTY WORK OR MATERIALS APPEARING DURING THE ABOVE MENTIONED PERIOD SHALL BE IMMEDIATELY MADE GOOD BY THE CONTRACTOR AT HIS OWN EXPENSE TO THE ENTIRE SATISFACTION OF THE OWNER AND ARCHITECT AND ENGINEER. SUCH RECONSTRUCTION AND REPAIRS SHALL INCLUDE ALL DAMAGE TO THE FINISH OR FURNISHING OF THE BUILDING RESULTING FROM THE ORIGINAL DEFECT OR REPAIRS THERETO. 3.10 TRAINING SERVICES THOROUGHLY INSTRUCT THE OWNER'S REPRESENTATIVE IN THE OPERATION OF ALL EQUIPMENT FURNISHED AND LOCATION OF ALL VALVES AND CONTROL DEVICES. TRAIN BUILDING OWNER'S PERSONNEL DURING NORMAL WORKING HOURS ON START-UP AND SHUT- DOWN PROCEDURES, TROUBLESHOOTING PROCEDURES, SERVICING AND PREVENTATIVE MAINTENANCE SCHEDULE AND PROCEDURES. REVIEW WITH THE OWNER'S PERSONNEL, THE DATA CONTAINED IN THE OPERATING AND MAINTENANCE MANUALS. SCHEDULE TRAINING WITH OWNER, PROVIDE AT LEAST 7-DAYS PRIOR NOTICE TO ARCHITECT/ENGINEER. www.brph.com Copyright © 2014 Architects, Engineers 2727 Paces Ferry Road I Bldg 1 I Suite 1800 Atlanta I Georgia 1 30339 770-933-9242 1 770-933-9246 f Offices in Melbourne, Orlando, West Palm Beach, Atlanta, Charleston, Seattle These plans are protected by Federal Copyright protection. Unauthorized use may result in an infringement action. ISSUE FOR PERMIT AND CONSTRUCTION REVISION r In M M J J � m O G 06 V♦ ) J = = W W. = W N 0 � ..J z 0 w W V ,J 0 r `X%%11111111� R ° •� * S No. 3737h 1 PROFFESSIONAL ''4 �/ F. 1 .T ��. ARCH/ENGR OF RECORD BEN TRANWICK FL PE 37376 DESIGNED BY CEJ DRAWN BY CEJ CHECKED BY JST PROJECT NUMBER C06898.057.00 DATE 05/22/14 TITLE MECHANICAL SPECIFICATIONS DRAWING NO. M002 m II I11 11 111 1 11 IT1I I 11,11d:A 11. 1A ... 1'I'l .I 11hill ,; I i 1 11 'h IC I I0 ❑C A O LJ1 L = NU L W T�I L J A �� N 1 � J � J aZ: o� r= oa r_� w Lo N 06 11 rn o0 UW N co m r :3 0) 0 o U� N n U cw MANUFACTURER PROVIDED WALL CAP �47 ,.:x r.....,,.. .....<.�..i �'��� Ma"Im M&O"WARNWO&'42M Q 010M Qmwmwmam�:a& Q'I'MaD x..�..�, 0x�=10' '�„�`^.��'%0 www awsm, qawnw&":=a ,.,-.::. .,,., ;a;...: MEM El w�`�,�,au�x�.ti .�,...�.�.. bWO'sMOMM ON" 4MM, C ... » .'°ASSSM 69AXIMONNEW :a+, ..... ... ....... u P, O E 1 f.• SD-1 250 CFM 10" o CU-1 ON THE ROOF RG-1 23 3 23 4 P STRbom HVAC FLOOR PLAN 1 /4,I = 1'-0" 10"xl 2" 10'o 6"x12" 0 EF-1 II RG-1 0"o SD-1 270 CFM SALES I I 26"x18" SD-1 270 CFM SD-1 270 CFM SD-1 270 CFM � I F � - - - - - - - - - - - - . . . . . . . . . . . SDA 270 CFM 1 10"x12" 1 ws - a P �: s� � sue, •,:•a» m �ZOR�`'�"�`�� wt a, .,xr � �vs " o-t"a. �s-��-a 'tuna ""A an m� m m axaezaa i ems...: W .,•M _._Q, ' z' s ,�3.,k W. 4€�"L M . ' > x�"a� '" � a� mra'0°"��•`.�..'• 00 SNU Qc`�=,�. GENERAL NOTE 23-1 INSTALL NEW 20X20 SUPPLY AIR DUCT DOWN FROM THE EXISTING ROOF -TOP UNIT. TRANSITION TO FULL SIZE OF UNIT OPENING IN THE VERTICAL. 2372 INSTALL NEW 26X18 RETURN AIR DUCT DOWN FROM THE EXISTING ROOF -TOP UNIT. TRANSITION TO FULL SIZE OF UNIT OPENING IN THE VERTICAL. 23-3 NEW DUCTLESS SPLIT -SYSTEM SERVING ELECTRICAL ROOM CONDENSING UNIT SHALL BE MOUNTED ON ROOF. CONTRACTOR SHALL ROUTE AND INSTALL REFRIGERANT PIPING PER MANUFACTURER'S INSTALLATION REQUIREMENTS, INCLUDING ALL VALVES AND OTHER APPURTENANCES AS NECESSARY. 23-4 ROUTE CONDENSATE DRAIN TO ADJACENT WALL BOX. SEE PLUMBING PLANS FOR EXACT LOCATION. , I i www.brph.com Copyright © 2014 Architects, Engineers 2727 Paces Ferry Road I Bldg 1 1 Suite 1800 Atlanta I Georgia 1 30339 770-933-9242 1 770-933-9246 f Offices in Melbourne, Orlando, West Palm Beach, Atlanta, Charleston, Seattle These plans are protected by Federal Copyright protection. Unauthorized use may result in an infringement action. ISSUE FOR PERMIT AND CONSTRUCTION REVISION 0 TM IV L I M M ft mi U. J VJ//1 J _ Z _ J 0 m _ �.. 0 0 = aLLI w N 06 = o W F J U� Q W ao N it ``\`\\\ • � 1 R F �. �',,'' a i No. 37376 1 PROFFESSIONAL W "1111111\,\\ ARCH/ENGR OF RECORD BEN TRANWICK FL PE 37376 DESIGNED BY CEJ DRAWN BY CEJ CHECKED BY JST PROJECT NUMBER C06898.057.00 DATE 05/22/14 TITLE HVAC FLOOR PLAN DRAWING NO. 1 2 K El E C BAND OF AS HANGEr, o i r mr G90 GALVANIZED TRANSFER AIR DUCT WITH LINER OR NON-METAL DUCT EQUAL TO MANVILLE SUPERDUCT DUCTWORK SHALL MATCH NECK SIZE OF GRILLE. INSULATION WF GALVANIZED RI DUCT SHIELD MIN. 12" LONG NTS ROUND DUCT HANGER DETAILS 18 GA. SLEEVE ESCUTCHEON NOT REQUIRED STD IN CONCEALED ESCUTCHEON IN SPACES FINISHED OR EXPOSED AREAS UL RATED INSULATED OR FIRE SAFING UNINSULATED PIPE WALL PENETRATION DETAIL NTS 2" DUCT FL AROUND PERIMETEI OF OPENI� WALL HANGER MUST NOT DEFORM DUCT SHAPE DUCT 4UGE ANIZED L TYPICAL NON -RATED WALL OPENING DETAIL NTS PROVIDE SUPPORTS AT ALL FOUR CORNERS OF AIR DEVICE ---------------- i I i SEE DUCT CONTINUATION IF INSTALLATION IS FOR RETURN OR TRANSFER AIR i EQUAL TO NECK SIZE i i r T-BAR IF REQUIRED B ACOUSTICAL CEILING TILE RETURN AIR OR HARD CEILING DEVICE (SEE SCHEDULE) 1. PAINT INTERIOR OF RETURN AIR AND TRANSFER AIR DUCTS BLACK WHERE USABLE FROM BELOW RETURN AIR AND TRANSFER AIR GRILLE DETAIL NTS 4 �o J N LL I —U w T �IA �L �� N J od H J r= od c6 a oc co V 12N cca aN o c 2 o UCn — N 0 CO U co 1 2 DUCT ELBOWS W � R=1/2W DUCTS W/ AIR VELOCITY UNDER 1,000 FPM R=W DUCTS W/ AIR VELOCITY OVER 1,000 FPM AND ALL DUCTS UPSTREAM OF TERMINAL UNITS - OTHERWISE PROVIDE TWO FULL LENGTH TURNING VANES. 12"x12" ACCESS PANEL ON BOTTOM OF DUCT UPSTREAM OF TURNING VANES. REQUIRED FOR RETURN AND EXHAUST DUCTS TURNING VANES CHANGE OF DUCT SIZE MAX. 15' + [:E" TRANSITION CONICAL SPIN -IN OR TRANSITION TO AT LEAST 70% GREATER THAN AREA OF SMALLER DUCT. SEE MAX. TRANSITION ANGLE. END TAP DUCT FITTING REQUIREMENTS FLEXIBLE DUCT FLEX DUCT CLAMP SPIN - IN FITTING WITH VOLUME DAMPER SUPPLY AIR DUCT - INSULATE SPIN - IN WITH 2" THICK INSULATION WITH VAPOR BARRIER LEAVING DAMPER OPERATOR ACCESSIBLE METAL GALV. SADDLE MIN.12" LONG SUPPORT FROM STRUCTURE ABOVE AT 4'-0" INTERVALS WIRE SUSPENSION SYSTEM MAX FLEXIBLE DUCT RUN OUT SHALL NOT EXCEED 6 FEET. INSULATE BACK OF DIFFUSER OR GRILLE I I�I CEILING LAY -IN TILE FIXTURE WHERE APPLICABLE AIR FLOW DUCT/DIFFUSER LAYOUT DETAIL NTS OFFSETS BRANCH DUCT TAKEOFFS W/ MINIMUM PRESSURE NOTE: OFFSETS (TO AVOID OBSTRUCTIONS) ARE REQUIRED BUT DROP ARE NOT NECESSARILY SHOWN ON THE PLANS. MAX. 15' 45' OR 90' RADIUS ELBOWS OBTAIN PRIOR APPROVAL FOR ALL RETURN & EXHAUST LOCATIONS 'URNING VANES -%,,LESS PANEL (TYPICAL) REQUIRED FOR RETURN & EXHAUST DUCTS eNOD�TESS THAN TWICE THE DUCT AREA R.,uima OR RECTANGULAR 'D= 2W, BUT NOT MORE THAN 12" (1/3W OK IF UNDER 3,000 FPM) -i W I— R=1/2W DUCTS W/ AIR VELOCITY UNDER 1,000 FPM R=W DUCTS W/ AIR VELOCITY OVER 1,000 FPM AND OUTDOOR CONDENSING UNIT FOR DUCTLESS SPLIT SYSTEM INSULATE SUCTION LINE WITH 2" THICK FLEXIBLE ELASTOMERIC INSULATION BY ARMACELL OR APPROVED EQUAL. PROVIDE PVC OR METAL JACKET. ALUMINUM CAP (MATCH PARAPET CAP) SEE ARCHITECTURAL PLANS FOR CURB/ROOF FLASHING INSTALLATION. CURB AND FLASHING BY ROOF CONTRACTOR. ANCHOR PER MANUFACTURER'S RECOMMENDATIONS TO STRUCTURAL SUPPORT FRAMING. PROVIDE WITH NEOPRENE GROMMETS IN FACTORY MOUNTING HOLES TO SECURE UNIT CONDENSING UNIT DETAIL NTS BE RECTANGULAR AIR DUCT ROUND SUPPLY AIR DUCT TAKE -OFF DETAIL CONTINUOUS THREADED R( ATTACH TO STRUCTURE RECTANGULAR DUCT CONICAL SPIN -IN WASHER (TYP) ROUND DUCT RUNOUT TO SINGLE DIFFUSER OR GRILLE OK ONLY ONLY UNDER 1,500 FPM LOCK -NUT (TYP) THE FOLLOWING DUCT FITTINGS ARE CONSIDERED ACCEPTABLE. THE CONTRACTOR SHALL OBTAIN ENGINEER'S APPROVAL FOR OTHER FITTINGS PRIOR TO FABRICATION. ONLY FITTINGS WITH EQUAL OR LOWER PRESSURE DROP WILL BE CONSIDERED. 3 5 NTS Tnnnr�r unni�rnc� NOTES: 1. USE TRAPEZE HANGERS FOR SUPPLY/RETURN/EXHAUST DUCTS 2. MAXIMUM SPACING BETWEEN HANGER LOCATIONS SHALL BE 8'-0" PER PAIR. 3. GALVANIZED SHEET METAL SHIELD. MINIMUM 16 GAGE x12" LONG. DUCT HANGER DETAIL NTS SHEET METAL SHIELD www.brph.com Copyright © 2014 Architects, Engineers 2727 Paces Ferry Road I Bldg 1 1 Suite 1800 Atlanta I Georgia 1 30339 770-933-9242 1 770-933-9246 f Offices in Melbourne, Orlando, West Palm Beach, Atlanta, Charleston, Seattle These plans are protected by Federal Copyright protection. Unauthorized use may result in an infringement action. ISSUE FOR PERMIT AND CONSTRUCTION REVISION 0 r In M M J J U_ ~ Uj � Z J 0 = = w CO G W N ,� _ W w > .. j �+ � Q W m N -J r .•. s T O i 3737n 1 * — 's PROFFESSIONAL ARCH/ENGR OF RECORD BEN TRANWICK FL PE 37376 DESIGNED BY CEJ DRAWN BY CEJ CHECKED BY JST PROJECT NUMBER C06898.057.00 DATE 05/22/14 TITLE MECHANICAL DETAILS DRAWING NO. M501 E J Ifl ROOF TO P U NIT SCH EDU LE EXISTING) Tag MANUFACTURER MODEL SERVICE AREA NOMINAL TONNAGE SUPPLY FAN (HP) _.:. _... HP ESP' SUPPLY AIRFLOW OUTDOOR AIR COOLING CAPACITY ELECTRICAL VPN NOTES Total Sensible CFM CFM MBH MBH RTU (EXISTINGI TRANS TSC072 SALES 6.0 __ __ 2120 310 -- -- 209/3 1-4 1. COORDINATE ELECTRICAL RECLUIREMENTSWITH ELECTRICAL DRAWINGS. . VERIFY! AND SECURE EQUIPMENT MOUNTING ON ROOF AS NECESSARY. 3. MANUFACTURER PROVIDED 7-DAY PROGRAMMABLE THERMOSTAT. . MANUFACTJRER PROVIDED DISCONNECT. GRILLES, REGISTERS & DIFFUSERS TAG MANUFACTURER MCIDEL DESCRIPTION SIZE NECKSI7E DAMPER. NOTES SIB-1 TITUS TDCA•AA LOUVERED FACE -AD1 24X24 AS NOTED NONE 1-4 G-1 TITUS PAR -AA PERF FACE 24X24 AS NOTED NONE 1-4 NOTES: L COORDINATE BORDER FRAME MOUNTING REQUIREMENTS WITH CEILING APPLICATION TYPE.. 2. MATERIAL SHALL BE ALUMINUM. 3. BALANCING DAMPER SHALL BE PROVIDED AT GRILLES AND DIFFUSERS WHERE BRANCH DUCT CONNECTION IS NOT ACCESSIBLE. 4. COLOR AS SPECIFIED BY ARCHITECT. BRANCH DUCT SIZING SCHEDULE SUPPLY AIRFLOW NECK .SIZE RETURN AIRFLOW (CFM) (CFM) 4"0 0-50 0-5 51' 51-120 51-100 "� + 121- 210 101- 175 1000211- 321] .... 171 - 275 "._.270- 1211 _ 321.- 470 400 14" _ 471- 6 401- 535 16H p 1- 700 536 - 700 1. NECK 512E AS INDICATED IN TABLE ABOVE OR SHOWN ON PLANS. DWAUST FAN SCHEDULE MOTOR TAG MANUFACTURER MODEL SERVICE TYPE CF ISP (in g SIP or RPM DRIVE INTERLOCK. 'BOLT, PH NOTES EF-1 PENN BARRY ZEPHYR 7T PROPOSED RESTROOM-102 CEILING 75 0.375 48 W 1290 DIRECT LIGHT SWITCH 11554 1- 1. COORDINATE ELECTRICAL REQUIREMENTS WITH ELECTRICAL O, 2. MANUFACTURER PROVIDED O 3. MANUFACTURER PROVIDED BACKDRAFT 4 MANUFACTURER PROVIDED ELECTRONIC SPEED CONTROLLER. 5. MANUFACTURER PROVIDED TIME -DELAY SWITCH FOR, INTERLOCK WITH LIGHT. 6. MANUFACTURER PROVIDED: WALL CAP;. PROVIDE WITH BACKDRAFT DAMPER AND INSECT SCREEN. DUCTLESS SPLIT -SYSTEM SCHEDULES TOTAL MODEL (INDOOR/OUTDOOR) M'Ca'04 ING mmmm NOTES: 1. COOLING CAPACITYBASED O °F db 67 "F Wb INDOOR ENTERING AIR CONDITIONS. . COOLING ONLY UNIT WITH LOW AMBIENT OPERATION. . PROVIDE LITTLE GIANT CONDENSATE PUMP R APPROVED EQUAL). ROUTE CONDENSATE TO ADJACENT T ''ALL BOA. 4. MA UFA TURE:ER PROVIDED FILTER.. 5. STANDARD COOLINGONLY THERMOSTAT. AT. . PROVIDE LONG LI ". ESET KIT AS NEEDED PER MANUFACTURERS INSTALLATION INSTRUCTIONS. 7. AIRFLOW SCHEDULED, IS FOR, MEDIUM FAN SPEED. www.brph.com Copyright © 2014 Architects, Engineers 2727 Paces Ferry Road I Bldg 1 1 Suite 1800 Atlanta I Georgia 1 30339 770-933-9242 1 770-933-9246 f Offices in Melbourne, Orlando, West Palm Beach, Atlanta, Charleston, Seattle These plans are protected by Federal Copyright protection. Unauthorized use may result in an infringement action. ISSUE FOR PERMIT AND CONSTRUCTION REVISION 0 In M M J J LL — J _ � J _ z Q O G Q J = W N _ W N w mi M W J J W W V, 0 r o� No. 37376 1 * _ PROFFFSSIONAL Z: ARCH/ENGR OF RECORD BEN TRANWICK FL PE 37376 DESIGNED BY CEJ DRAWN BY CEJ CHECKED BY JST PROJECT NUMBER C06898.057.00 DATE 05/22/14 TITLE MECHANICAL SCHEDULES DRAWING NO. M601 1 2 K `l J ABBREVIATIONS PLUMBING SYMBOLS and LEGEND GENERAL PLUMBING NOTES C ❑C fo c 0 ch CIS a) NLO LA0 o� �a. 0 N 3 'rn 0 o in C\1 � i N U —co ABBR DESCRIPTION ABBR DESCRIPTION AS ABOVE SLAB KW KILOWATT ADA AMERICANS WITH DISABILITIES ACT AFF ABOVE FINISHED FLOOR LAV LAVATORY AFG ABOVE FINISHED GRADE LF LINEAR FEET ANSI AMERICAN NATIONAL STANDARDS INSTITUTE AP ACCESS PANEL MAX MAXIMUM ASTM AMERICAN STANDARDS TESTING MATERIALS MIN MINIMUM AWWA AMERICAN WATER WORKS ASSOCIATION MNTG MOUNTING MS MOP SINK BFP BACKFLOW PREVENTER BS BELOW SLAB NA NOT APPLICABLE BFF BELOW FINISH FLOOR NC NORMALLY CLOSED NIC NOT IN CONTRACT CD CONDENSATE NO NORMALLY OPEN CO CLEANOUT NSF NATIONAL SANITATION FOUNDATION CONN CONNECTION NTS NOT TO SCALE CONT CONTINUOUS CP CIRCULATING PUMP OD OUTSIDE DIAMETER CV CHECK VALVE CW COLD WATER PDI PLUMBING DRAINAGE INSTITUTE PH PHASE DF DRINKING FOUNTAIN PPP PRECISION PLUMBING PRODUCTS DFU DRAINAGE FIXTURE UNITS PSI POUNDS PER SQUARE INCH DIA DIAMETER DN DOWN RPM REVOLUTIONS PER MINUTE DWG DRAWING RWL RAIN WATER LEADER ECO EXTERIOR CLEANOUT SAN SANITARY ELEV ELEVATION SAN U/G SANITARY UNDERGROUND EQUIP EQUIPMENT SH SHOWER EWC ELECTRIC WATER COOLER SK SINK EWH ELECTRIC WATER HEATER SPEC SPECIFICATION EXIST EXISTING SQ SQUARE SS STAINLESS STEEL OF DEGREES FAHRENHEIT STD STANDARD FCO FLOOR CLEANOUT FD FLOOR DRAIN TDH TOTAL DYNAMIC HEAD FIN FINISH TEMP TEMPERATURE FL FLOOR TET THERMAL EXPANSION TANK FPS FEET PER SECOND TMV THERMOSTATIC MIXING VALVE FS FLOOR SINK TP TRAP PRIMER FT FEET TYP TYPICAL FU FIXTURE UNITS UL UNDERWRITER'S LABORATORY GAL GALLON(S) LINO UNLESS NOTED OTHERWISE GPM GALLONS PER MINUTE UR URINAL GW GREASE WASTE V VOLTS HB HOSE BIBB VTR VENT THROUGH ROOF HP HORSEPOWER VIV VALVE IN VERTICAL HR HOUR VLV VALVE HWR HOT WATER RETURN VOL VOLUME HZ HERTZ W WATTS IE INVERT ELEVATION W/ WITH ID INTERNAL DIAMETER WC WATER CLOSET IN INCHES WCO WALL CLEANOUT IPS INTERNATIONAL PIPE STANDARD WHA WATER HAMMER ARRESTOR IRR IRRIGATION WATER WHY WALL HYDRANT WFU WATER SUPPLY FIXTURE UNITS ** NOT ALL ABBREVIATIONS ARE USED ** CW _ = HW V SAN SAN GR W KV=====___ � FD FCO CO GCO low ** NOT ALL SYMBOLS ARE USED ** DOMESTIC COLD WATER HOT WATER TEMPERED (110F) EXISTING PIPING PIPING TO BE DEMOLISHED VENT SANITARY PIPE BELOW SLAB SANITARY PIPE ABOVE SLAB GREASE WASTE PIPE BELOW SLAB WASTE PIPE BELOW SLAB KITCHEN VENT PIPE TURNING DOWN PIPE TURNING UP GATE or BALL VALVE CHECK VALVE HOSE BIBB FLOOR DRAIN W/ TRAP PRIMER FLOOR CLEANOUT WALL CLEANOUT GRADE CLEANOUT SHOCK ABSORBER DIRECTION OF FLOW (WATER) DIRECTION OF SLOPE (SEWER) PLUMBING FIXTURE NUMBER HOT WATER MIXING VALVE PRESSURE REDUCING VALVE (PRV) BACKFLOW PREVENTER (BFP) NON -FREEZE WALL HYDRANT (W.H.) ROOF HYDRANT 1. ALL PLUMBING WORK SHALL BE IN ACCORDANCE WITH 2O10 FLORIDA BUILDING CODE - PLUMBING. 2. ANCHOR EXPOSED VERTICAL WATER PIPES TO WALLS WITH HOT -DIPPED GALVANIZED UNI-STRUT CHANNELS AND CUSHIONED/SHOULDER BOLT CLAMP. 3. INSTALL HORIZONTAL EXPOSED PIPES AS CLOSE TO THE CEILING AS POSSIBLE. 4. CONTRACTOR SHALL COORDINATE ACTUAL LOCATIONS OF MECHANICAL FLOOR DRAINS AND CONDENSATE DRAINS WITH HVAC FINAL EQUIPMENT LOCATIONS ON SHOP DRAWING 5. PROVIDE AND INSTALL WATER HAMMER ARRESTORS IN ALL HW AND CW SUPPLY PIPING IN ACCORDANCE WITH PDI-WH2O1 STANDARDS. SEE SCHEDULE FOR SIZES. AIR CHAMBERS ARE NOT ACCEPTABLE SUBSTITUTIONS. COORDINATE ACCESS PANEL OR PROVIDE SIOUX CHIEF MODEL WHICH DOES NOT REQUIRED ACCESS PANELS. 6 THE DRAWINGS ARE GENERALLY INDICATIVE OF THE WORK TO BE INSTALLED AND DO NOT INDICATE ALL OFFSETS, FITTINGS AND SIMILAR DETAILS WHICH MAY BE REQUIRED. THE CONTRACTOR SHALL CAREFULLY INVESTIGATE THE STRUCTURAL AND FINISH CONDITIONS AFFECTING ALL WORK AND ARRANGE ACCORDINGLY, FINISHING SUCH OFFSETS, FITTINGS, VALVES AND OTHER SIMILAR DETAILS AS MAY BE REQUIRED TO MEET SUCH OFFSETS. 7. CONTRACTOR SHALL BE RESPONSIBLE UNDER THIS SPECIFICATION FOR THE PROPER COORDINATION OF ALL WORK WITH THE RELATED WORK OF OTHER TRADES, CRAFTS, CONTRACTORS, SUBCONTRACTORS, ETC. EMPLOYED ON THE PROJECT, TO INSURE A COMPLETE NEAT AND WORKMANLIKE INSTALLATION. 8. THOROUGHLY READ SPECIFICATIONS BEFORE STARTING WORK OR ORDERING MATERIALS. 9. DO NOT INSTALL PIPING ABOVE ELECTRICAL PANELS, SWITCHGEAR THROUGH ELECTRICAL AND DATA ROOMS. 10. ALL SANITARY PIPING 2-1/2" OR LESS SHALL BE SLOPED AT 1/4" PER FOOT. ALL SANITARY PIPING 3" & LARGER SHALL BE SLOPED AT 1/8" PER FT. MINIMUM. 11. VERIFY LOCATIONS & SIZES OF EXISTING SITE UTILITIES BEFORE COMMENCING WORK. 12. PLUMBING SYSTEM VENTS THROUGH ROOF TO BE TEN FEET (MINIMUM) FROM HVAC FRESH AIR INTAKES (OR ROOF TOP UNITS) AND WINDOW OPENINGS. 13. PAINT EXPOSED PIPING TO MATCH SURROUNDINGS. COORDINATE EXACT REQUIREMENTS WITH SPECIFICATION AND/OR ARCHITECT. 14. MANUFACTURER'S AND MODELS NUMBERS FOR PLUMBING EQUIPMENT ARE BASIS OF DESIGN. APPROVED EQUIVALENTS ARE PERMITTED. 15. COORDINATE ALL CEILING PIPING ELEVATIONS IN SHOP DRAWINGS WITH HVAC, FIRE PROTECTION AND ELECTRICAL TRADES TO ENSURE CLEARANCES AND PENETRATIONS, PRIOR TO INSTALLATION. 16. ALL VALVES SHALL BE LOCATED IN ACCESSIBLE AREAS AS DEFINED BY THE FLORIDA PLUMBING CODE. CONTRACTOR SHALL PROVIDE ACCESS DOORS WHERE NECESSARY. (12"X12" MIN.) 17. COORDINATE ALL PLUMBING EQUIPMENT/FIXTURE REQUIREMENTS WITH THE CASEWORK DRAWINGS. 18• VALVES AND FITTINGS SHALL BE THE SAME SIZE AS THE PIPING WHERE THEY ARE LOCATED UNLESS NOTED OTHERWISE. 19. THE CONTRACTOR SHALL PROVIDE ALL NECESSARY SUPPORTING DEVICES FOR ALL FIXTURES INCLUDED IN THIS CONTRACT OR SPECIFIED HEREIN. PLUMBING FIXTURE SCHEDULE MARK DESCRIPTION WASTE VENT CW HW FLOW ELECTRICAL MANUFACTURER MODEL REMARKS TWO PIECE FLOOR MOUNTED, ELONGATED, ADA COMPLIANT. PROVIDE WITH OLSONITE 10CT TOILET SEAT. P-1 WATER CLOSET 4" 2" 3/4" --- 1.6 GALLONS/FLUSH ------- SLOAN WETS 9023-1.6 _______ WALL HUNG LAVATORY, ADA COMPLIANT 4" CENTER. P-2 LAVATORY 1-1/4" 2" 1/2" 1/2" 0.5 GPM SLOAN SS-3003-4" FAUCET: CHICAGO MODEL 420-E2805ABCP ------- HIGH IMPACT POLYSTYRENE, 2 SUPPORT BRACKETS, SNAP -ON FACEPLATE FRAME W ZURN Z1024 FIXED AIR GAP, P-3 CONDENSATE 1-1/4" 2" ----- ----- ----- OATEY 38751 DURA COATED CAST IRON BODY WITH SLIP JOINT INLET AND NPT OUTLET WALL BOX 1 �j ELECTRIC WATER HEATER SCHEDULE STORAGE MANUFACTURER INLET SIZE OUTLET ELECTRICAL ROOM TAG (GALS) & MODEL # (IN.) S SIZE (IN) NUMBER V PH HZ AMPS KW EWH-1 NA EEMAX SP3208 1/2" 112" 208 1 60 15 3 RESTROOM 102 3 WATER HAMMER SCHEDULE ARRESTOR SIZE (WHA) WATER SUPPLY FIXTURE UNITS PDI STD WH 201 1/2" 1-11 PDI-A 3/4" 12-32 PDI-B ill 33-60 PDI-C 1-1/4" 61-133 PDI-D 1-1/2" 114-154 PDI-E 2" 155-330 PDI-F NOTE: ALL ARRESTORS SHALL BE INSTALLED PER PDI (PLUMBING AND DRAINAGE INSTITUTE) STANDARD PDI- WH2O1 (2006) FOR SIZING AND PLACEMENT. PLUMBING SPECIFICATIONS GENERAL THE GENERAL MECHANICAL SPECIFICATIONS APPLY TO THE WORK SPECIFIED IN THIS SECTION. SCOPE OF WORK PROVIDE A COMPLETE PLUMBING SYSTEM AS INDICATED ON THE DESIGN DRAWINGS AND AS OUTLINED WITHIN THESE SPECIFICATIONS. WORK SHALL INCLUDE BUT NOT BE LIMITED TO SELECTIVE DEMOLITION, THE FABRICATION AND/OR INSTALLATION OF THE SCHEDULED PLUMBING FIXTURES AND RELATED PIPING. THE COMPLETED PLUMBING SYSTEM SHALL MEET ALL APPLICABLE CODES AND STANDARDS. WATER SUPPLY SYSTEM: PROVIDE SHOCK ABSORBERS AND VACUUM BREAKERS WHERE REQUIRED. PIPE AND FITTINGS ABOVE SLAB - TYPE L HARD COPPER, ASTM B88 AND WROUGHT COPPER SOLDER -JOINT FITTINGS AND BRAZED JOINTS. (USE ONLY "LEAD FREE" SOLDER).. PIPE AND FITTINGS BELOW SLAB - TYPE "K" SOFT COPPER. ASTM B88 AND WROUGHT COPPER, SOLDER JOINT FITTINGS AND BRAZED JOINTS. PROVIDE POLYBUTYLENE WRAPPING. VALVES (2-1/2 INCH AND SMALLER) TWO PIECE 400 PSI WSP FULL PORT BRONZE BODY BALL VALVE WITH THREADED ENDS, LOCKABLE LEVER HANDLE AND REPLACEABLE TEFLON OR TFE SEATS CHLORINATION - BEFORE BEING PLACED IN SERVICE ALL WATER DISTRIBUTION SYSTEMS SHALL BE STERILIZED WITH CHLORINE IN ACCORDANCE WITH PLUMBING CODE AND AWWA C-651 OR C-652 STANDARD PROCEDURE FOR DISINFECTING WATER MAINS. SHOCK ARRESTOR: MIFAB, SIOUX CHIEF OR EQUAL DRAINAGE SYSTEM: EXTEND PIPING FROM NEW FIXTURES AND EQUIPMENT AND CONNECT TO SYSTEMS AS INDICATED ON THE DRAWINGS. PIPE SLOPE: 2-1/2 INCH DIAMETER AND LESS SHALL BE INSTALLED WITH A FALL OF NOT LESS THAN 1/4 INCH PER FOOT. 3 INCH DIAMETER OR LARGER SHALL BE INSTALLED WITH A FALL NOT LESS THAN 1/8 INCH PER FOOT. PROVIDE CLEANOUTS EVERY 75 FEET, AT CHANGES IN DIRECTION, AT BASE OF DOWNSPOUTS AND AT BASE OF SOIL AND WASTE STACKS. WALL CLEANOUT: MIFAB, ZURN, JONESPEC, JOSAM OR EQUAL. FLOOR CLEANOUT: MIFAB, ZURN, JONESPEC, JOSAM OR EQUAL. VENTS SHALL BE EXTENDED TO EXTERIOR OF BUILDING. AIR ADMITTANCE VALVES ARE NOT ACCEPTABLE. PIPE AND FITTINGS ABOVE SLAB -HUBLESS CAST IRON SOIL PIPE AND CISPI HUBLESS PIPING COUPLINGS AND COUPLED JOINTS. PIPE AND FITTINGS BELOW SLAB - SERVICE CLASS - CAST IRON SOIL PIPING AND GASKETED JOINTS. 5 I 6 www.brph.com Copyright © 2014 Architects, Engineers 2727 Paces Ferry Road I Bldg 1 I Suite 1800 Atlanta I Georgia 1 30339 770-933-9242 1 770-933-9246 f Offices in Melbourne, Orlando, West Palm Beach, Atlanta, Charleston, Seattle These plans are protected by Federal Copyright protection. Unauthorized use may result in an infringement action. ISSUE FOR PERMIT AND CONSTRUCTION REVISION L 1♦ M� W 5O G W Z O V w 0. W U) w % 11111,,, �,�C•,�Sf•F7F.� No. 37376 1 PROFESSIONAL ARCH/ENGR OF RECORD BENJAMIN E. TRAWICK, JR. FL PE 37376 DESIGNED BY BDS DRAWN BY BIDS CHECKED BY BET PROJECT NUMBER C06898.057.01 DATE 08/12/14 TITLE PLUMBING LEGENDS AND SCHEDULES DRAWING NO. Pool BACK OF HOUSE 0 PLUMBING NEW WORK KEYED NOTES: 22-XX www.brph.com Copyright © 2014 C C C R co 0 N� C_ E a J� LL NI L T L Q. N NI 0A 0 CD 0) co co w C E U O o� a o c0 w 0 ui o Z) N 22-01 ..,>re.e&.. AWM � ", *UW QMWOMWAMMAD MEW $n°OMMIMIa� A M.Uft a.ra am .., . ;,.�.5 L4k9 '� § 1'••3" : PLUMBING PLAN 22-03 5�� % "1*03/4" o ♦ G� 3/4"o ' 3/4"o U P-2 1 1 n DOMESTIC WATER RISER DIAGRAM U '-1 22-04 II 3„o I� 22-02 2"0 II an" IIII Yo 2'0 115 �3,.0 ?]I n Pj"o III I I 3„ o P-2 11 4"o � 4"W.C.O. Sa. _ P-1 "0 4"o-i V:"U "-4,,o SANITARY WASTE AND VENT RISER DIAGRAM 22-01 EXISTING 4"SANITARY AND 1 1/2"CW LINES SHOWN DERIVED FROM EXISTING DRAWINGS. CONTRACTOR SHALL FIELD VERIFY EXACT LOCATION OF EXISTING TIE-IN LOCATIONS PRIOR TO CONSTRUCTION. 22-02 CONNECT NEW 4"SANITARY TO EXISTING 4"SANITARY BELOW SLAB. COORDINATE INVERT ELEVATIONS. 22-03 CONNECT NEW 3/4"CW LINE TO EXISTING 1 1/2"CW STUB -OUT AND ROUTE NEW CW LINE ABOVE CEILING. 22-04 3"VENT UP TO 3"VTR. TERMINATE 3"VTR ABOVE ROOF. COORDINATE VTR LOCATION WITH FRESH AIR INTAKE AND MAINTAIN MINIMUM CLEARANCE OF 15'. 22-05 2"SANITARY UP TO LAVATORY WITH 2" VENT UP. 22-06 1/2" HOT AND COLD WATER DOWN BELOW SINK. PROVIDE ANGLE VALVES AND SUPPLIES TO SINK FAUCET. 22-07 4" SANITARY UP TO WATER CLOSET WITH 2"VENT UP. 22-08 3/4" COLD WATER TO WATER CLOSET. PROVIDE ANGLE VALVES AND SUPPLIES AS REQUIRED BY FIXTURE MANUFACTURER. 22-09 4"SANITARY UP TO WALL CLEANOUT. 22-10 ROUTE HVAC CONDENSAE TO WALL BOX. SEE MECHANICAL DRAWINGS FOR CONDENSATE DRAIN LOCATION. INSULATE CONDENSATE DRAIN LINE IN ITS ENTIRITY. 22-11 1/2"CW TO EWH-1, SEE SCHEDULE SHEET P001. 22-12 EXISTING 1 1/2"CW VALVED AND CAPPED. 22-13 PROVIDE 3/4"CW SHUT-OFF VALVE ABOVE CEILING. 0 2' 4' 8' 12' 1/4" = 1'-0" Architects, Engineers 2727 Paces Ferry Road I Bldg 1 1 Suite 1800 Atlanta I Georgia 1 30339 770-933-9242 1 770-933-9246 f Offices in Melbourne, Orlando, West Palm Beach, Atlanta, Charleston, Seattle These plans are protected by Federal Copyright protection. Unauthorized use may result in an infringement action. ISSUE FOR PERMIT AND CONSTRUCTION REVISION z\ Q mow/ 0. VJ LL w N me 11111111//1 611 1 * : No. 37376 i PROFESSIONAL // ARCH/ENGR OF RECORD BENJAMIN E. TRAWICK, JR. FL PE 37376 DESIGNED BY BET DRAWN BY BDS CHECKED BY BET PROJECT NUMBER C06898.057.01 DATE 08/12/14 TITLE PLUMBING FLOOR PLAN DRAWING NO. P 10 1 U a6 1 2 3 0 5 I>Ti 1­­ � Iii1AF;la. nL, C1 I IC C R C O a) C a) 0 NI U a) LU i D_ D� L C C- m N 0 ~A LO 0 co m 00 (0 U) C U O o 2 C (_ O a) C C9 a)NT d r `) o Z) M ELECTRICAL LEGEND LIGHTING O DOWNLIGHT 0- WALL MOUNTED FLUORESCENT OR INCANDESCENT LUMINAIRE, AS NOTED --� CEILING OR WALL MOUNTED HID LUMINAIRE @K PORCELAIN KEYLESS ® SURFACE MOUNTED FLUORESCENT LUMINAIRE 0 RECESS MOUNTED FLUORESCENT LUMINAIRE RECESS MOUNTED FLUORESCENT LUMINAIRE (EMERGENCY) �-a-� FLUORESCENT STRIP LUMINAIRE Q__= TRACK LIGHT, AS NOTED OR SCHEDULED p DIRECTIONAL ACCENT OR WALL -WASH LUMINAIRE ❑_0_❑ EXTERIOR POLE MOUNTED LUMINAIRE, AS SCHEDULED ❑ BOLLARD ® CEILING OR WALL MOUNTED EXIT SIGN, INSTALL FACES AS INDICATED BY SHADING EMERGENCY LIGHT AS NOTED SWITCHING $ WALL MOUNTED SWITCH SUBSCRIPTS: 2 = DOUBLE POLE 3 = 3-WAY 4 = 4-WAY D = DIMMER K = KEY -OPERATED 0 = SWITCH MOUNTED OCCUPANCY SENSOR P = PILOT LIGHT T= THERMAL OVERLOAD LV = LOW VOLTAGE DS = DOOR SWITCH M = MOTOR RATED SWITCH OS CEILING MOUNTED OCCUPANCY SENSOR POWER STRAIGHT BLADE DUPLEX RECEPTACLE SUBSCRIPTS: HG = HOSPITAL GRADE HGT = HOSPITAL GRADE TAMPER RESISTANT GFI = GROUND FAULT INTERRUPTER SS = SURGE SUPRRESSION AC = 6" ABOVE COUNTER STRAIGHT BLADE DOUBLE DUPLEX RECEPT. (FOURPLEX) e- STRAIGHT BLADE SINGLE RECEPTACLE STRAIGHT BLADE DUPLEX RECEPT. HALF -SWITCHED STRAIGHT BLADE DUPLEX RECEPT. ON EMERGENCY CIRCUIT ® OUTLET WITH SPECIAL DEVICE, AS NOTED WALL MOUNTED OUTLET WITH SPECIAL DEVICE, AS NOTED ® FLOOR MOUNTED QUAD RECEPTACLE, AS NOTED ® FLOOR MOUNTED DUPLEX RECEPTACLE, AS NOTED PEI FLOOR MOUNTED COMBINATION OUTLET BOX, AS NOTED ® STRAIGHT BLADE DUPLEX RECEPTACLE, CEILING OO POKE THROUGH, AS NOTED O PEDESTAL OUTLET, AS NOTED ❑J JUNCTION BOX AS NOTED ( OUTLET BOX ( H WALL MOUNTED OUTLET BOX �D ABOVE CEILING POWER DISTRIBUTION BOX SURFACE RACEWAY, AS NOTED TELE-POWER POLE PB PULL BOX OM CONNECTION TO MOTOR ® MAGNETIC MOTOR STARTER SUBSCRIPTS: MS = MULTISPEED SSRV = SOLID-STATE, REDUCED VOLTAGE VF = VARIABLE FREQUENCY OT WALL MOUNTED OUTLET BOX FOR THERMOSTAT NOTE: ALL SYMBOLS SHOWN ON LEGEND ARE NOT NECESSARILY USED. LS SAFETY DISCONNECT SWITCH (NON -FUSED) FIRE ALARM SYSTEM FUSED DISCONNECT SWITCH, 30/3/l/NF INDICATES FACP FIRE ALARM CONTROL PANEL 30AMP FRAME, 3-POLE, NEMA 1, NON -FUSED FAGP N COMBINATION DISCONNECT AND STARTER 0 FIRE ALARM GRAPHIC PANEL ENCLOSED CIRCUIT BREAKER, MOLDED -CASE, FAAP FIRE ALARM ANNUNCIATOR PANEL THERMAL -MAGNETIC Q MANUAL PULL STATION SUBSCRIPTS: FIRE ALARM STROBE AT = ADJUSTABLE TRIP �� ED< GENERAL ALARM COMBINATION HORN/STROBE EAT = ELECTRONIC ADJUSTABLE TRIP l< FIRE ALARM HORN CL = CURRENT LIMITING CEILING OR WALL MOUNTED DETECTOR IF = INTEGRALLY FUSED SUBSCRIPTS: GFCI = GROUND FAULT CIRCUIT INTERRUPTER I = IONIZATION ST = SHUNT TRIP T = THERMAL, FIXED AND RATE -OF -RISE KI = KEY INTERLOCK TF = THERMAL, FIXED ZSI = ZONE -SELECTIVE INTERLOCKING T165° =165`F THERMAL, FIXED AND RATE -OF -RISE CONNECTION TO PRE -WIRED EQUIPMENT TF165° =165°F THERMAL, FIXED 0 BREAKER PANEL P = PHOTOELECTRIC MCC MOTOR CONTROL CENTER PT = COMBINATION PHOTOELECTRIC AND THERMAL F­SS_1 TRANSIENT VOLTAGE SURGE SUPPRESSOR S = SMOKE IDTRANSFORMER OD SMOKE DETECTOR IN VENTILATING DUCT Rd ENGINE GENERATOR A FAN SHUT -DOWN CONNECTION Q MAG. DOOR HOLDER TC TIME CLOCK (Z> SPRINKLER SYSTEM FLOW SWITCH C1 LIGHTING CONTACTOR; NUMERAL INDICATES CONTACTOR NUMBER. SPRINKLER SYSTEM TAMPER SWITCH OFIREFIGHTERS TELEPHONE JACK CIRCUITING © F LIFE SAFETY SPEAKER CONDUIT RUN ED< LIFE SAFETY SPEAKER WITH STROBE CIRCUIT HOMERUN TO PANEL OR CABINET, NO. p O-I REMOTE PILOT LIGHT OF ARROWS INDICATE NO. OF CIRCUITS. WHERE SHOWN, HASH MARKS DENOTE THE P�O-I REMOTE PILOT LIGHT WITH TEST SWITCH FOLLOWING: '%" = HOT; 'r" = NEUTRAL; GROUND MONITOR MODULE --0 CIRCUIT TURNED UP � CONTROL MODULE CIRCUIT TURNED DOWN ® DAMPER CONNECTION — 3 CONDUIT STUB -OUT - CAP & MARK CIRCUIT IN FLEXIBLE CONDUIT COMMUNICATION SYSTEM SEALOFF In FLOOR MOUNTED TELEPHONE AND/OR DATA - _ _ _ _ _ - CONDUIT BELOW FLOOR OUTLET BOX, AS NOTED - SWITCHED POWER CIRCUIT. SEE WALL MOUNTED TELEPHONE OUTLET NOTE 14 ON SHEET E200. 0 WALL MOUNTED DATA OUTLET 0 WALL MOUNTED COMBINATION SCHEMATIC WIRING GRAPHICS TELEPHONE/DATA OUTLET BOX METER W WALL MOUNTED AT 48" WITH MOUNTING BRACKET GROUND CONNECTION AS NOTED —� FUSED DISCONNECT SWITCH Q QS -I CEILING OR WALL MOUNTED SPEAKER -1 lvr FUSES a VOLUME CONTROL d � MAGNETIC MOTOR STARTER O V FLOOR OR WALL MOUNTED MICROPHONE OUTLET SUBSCRIPTS: C CALL -IN SWITCH MS = MULTISPEED S J TIME -TONE UNIT SSRV = SOLID-STATE, REDUCED VOLTAGE JQ CEILING OR WALL MOUNTED CLOCK VF = VARIABLE FREQUENCY ©-I DOOR BELUCHIME ENCLOSED CIRCUIT BREAKER, MOLDED -CASE, © BUZZER THERMAL -MAGNETIC O HOUSE PHONE/INTERCOM SUBSCRIPTS: OI MASTER INTERCOM STATION AT = ADJUSTABLE TRIP TV TELEVISION ANTENNA OUTLET EAT = ELECTRONIC ADJUSTABLE TRIP CC CLOSED CIRCUIT TV OUTLET CL =CURRENT LIMITING Cad COAX OUTLET IF = INTEGRALLY FUSED AMPLIFIER GFCI = GROUND FAULT CIRCUIT INTERRUPTER V ST = SHUNT TRIP a TEMPERATURE SENSOR KI = KEY INTERLOCK ZSI = ZONE -SELECTIVE INTERLOCKING POWER TRANSFORMER NOTATIONS - CURRENT TRANSFORMER 1- UPPER CASE LETTER AT LUMINAIRES (F1,11, ETC.) Q AMMETER INDICATES LUMINAIRE TYPE. LUMINAIRES IN AREA OV INDICATED. WHERE NOTED, NUMBER ADJACENT TO VOLT METER LUMINAIRE TYPE INDICATES CIRCUIT NUMBER FOR THAT LUMINAIRE (E.G., F1/27) TRANSFER SWITCH. GF 2- LOWER CASE LETTER AT LUMINAIRES AND SWITCHES GROUND FAULT PROTECTION (a, b, ETC.) INDICATE ASSOCIATED UNITS FOR G GENERATOR 3- SWITCHING. DIAGONAL WITHIN LUMINAIRE DENOTES UNIT ON EMERGENCY (EM) CIRCUIT WITH BATTERY. 3 MOTOR, NUMBER INDICATES HORSEPOWER 4- "NL" WITHIN LUMINAIRES DENOTES UNIT ON NIGHT LIGHT CIRCUIT. PP LIGHTING CONTROL POWER PACK 5- PLUS (+) SIGN WITH DIMENSION AT OUTLET -I CONTACTOR INDICATES HEIGHT ABOVE FINISHED FLOOR OR GRADE TO CENTERLINE OF OUTLET. ABBREVIATIONS NOTE: ALL ABBREVIATIONS SHOWN ON LEGEND ARE NOT NECESSARILY USED. AC - ABOVE COUNTER AFC - ABOVE FINISHED CEILING AFF -ABOVE FINISHED FLOOR AFG -ABOVE FINISHED GRADE AIC -AMPS INTERRUPTING CURRENT AL -ALUMINUM BFG - BELOW FINISHED GRADE CB - CIRCUIT BREAKER CR - CORROSION RESISTANT CT - CURRENT TRANSFORMER CU -COPPER DISC - DISCONNECT EM -EMERGENCY ES - EMERGENCY STOP EWC - ELECTRIC WATER COOLER EX - EXISTING FLA - FULL LOAD AMPS FVNR - FULL VOLTAGE, NON -REVERSING FVR - FULL VOLTAGE, REVERSING FWE - FURNISHED WITH EQUIPMENT GFI - GROUND FAULT INTERRUPTER GRC - GALVANIZED RIGID CONDUIT HOA - HAND -OFF -AUTOMATIC HP -HORSEPOWER IG -ISOLATED GROUND LC - LIGHTING CONTACTOR MCA - MINIMUM CIRCUIT AMPS MCB - MAIN CIRCUIT BREAKER MCC - MOTOR CONTROL CENTER MCP - MOTOR CIRCUIT PROTECTION MLO - MAIN LUGS ONLY NC - NORMALLY CLOSED NIC - NOT IN CONTRACT NL - NIGHT LIGHT NO - NORMALLY OPEN NTS - NOT TO SCALE OC - OVER CURRENT OL -OVERLOAD PART - PARTIAL CIRCUIT POS - POINT OF SALES TTB - TELEPHONE TERMINAL BOARD UG -UNDERGROUND WG - WIREGUARD WP -WEATHERPROOF WSHP - WATER SOURCE HEAT PUMP XFMR -TRANSFORMER THESE DRAWINGS ARE DIAGRAMMATIC - REFER TO ARCHITECTURAL DRAWINGS FOR EXACT DIMENSIONS. BRANCH CIRCUITING CONVENTION - #12 AWG PER PHASE AND NEUTRAL (WHERE REQUIRED) AND 20 AMPERE CIRCUIT BREAKER, UNLESS OTHERWISE NOTED. PROVIDE QUANTITY AND SIZE SWITCH CONDUCTORS AS REQUIRED TO MAKE SYSTEM OPERATIONAL. GENERAL NOTES (FOR ALL ELECTRICAL SHEETS) 1. COORDINATE LOCATION OF LUMINAIRES WITH ARCHITECTURAL REFLECTED CEILING PLANS. 2. 3 AND 4 LAMP FIXTURES SHOWN WITH DIAGONAL SHALL HAVE INBOARD LAMP CONNECTED TO EMERGENCY BATTERY PACK. SEE SPECIFICATIONS. 3. PROVIDE (1) 3/4"C. (MIN) WITH PULL WIRE FROM EACH TELEPHONE, DATA OR COMMUNICATION OUTLET SHOWN, TO ABOVE ACCESSIBLE CEILING, AND CAP. 4. COORDINATE EXACT EQUIPMENT LOCATIONS WITH OWNER PRIOR TO ROUGH -INS. 5. COORDINATE LOCATION OF ALL OUTLETS WITH ARCHITECTURAL ELEVATIONS, CASEWORK SHOP DRAWINGS AND EQUIPMENT INSTALLATION DRAWINGS. 6. COORDINATE LOCATION OF MECHANICAL EQUIPMENT WITH MECHANICAL PLANS AND MECHANICAL CONTRACTOR PRIOR TO ROUGH -IN. 7. ANY ITEMS DAMAGED BY THE CONTRACTOR SHALL BE REPLACED BY THE CONTRACTOR. 8. ALL 120V BRANCH CIRCUITS SHALL BE 3-WIRE (PHASE, NEUTRAL, GROUND). 9. CONTRACTOR SHALL NOT ROUTE ANY CONDUIT WITHIN STRUCTURAL OR TOPPING SLABS OF FLOORS UNLESS NOTED TO DO SO. 10. REFER TO ARCHITECTURAL PLANS, ELEVATIONS AND DIAGRAMS FOR LOCATIONS OF FLOOR DEVICES AND WALL DEVICES. LOCATION WILL INDICATE VERTICAL AND/ OR HORIZONTAL MOUNTING. IF DEVICES ARE NOT NOTED OTHERWISE THEY SHALL BE MOUNTED LONG AXIS VERTICAL AT +16" TO CENTER. 11. INFORMATION ON THE DRAWINGS HAS BEEN ASCERTAINED FROM INFORMATION PROVIDED BY OTHERS. THIS INFORMATION IS AS ACCURATE AS CONDITIONS WOULD ALLOW. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO VISIT THE SITE, PRIOR TO BID, AND FAMILIARIZE HIMSELF WITH THE EXTENT OF REMODEL WORK REQUIRED. NO EXTRAS WILL BE ALLOWED FOR ALTERATIONS OF A FORESEEABLE NATURE REQUIRED TO ACHIEVE THE END RESULT AS INDICATED BY CONTRACT DOCUMENTS. 12. ALL NEW WIRING REQUIRED BY TENANT BUILDOUT SHALL BE FISHED THROUGH EXISTING WALLS OR CONCEALED IN NEW WALLS OR ABOVE CEILINGS. SURFACE MOUNTED CONDUIT SHALL NOT BE USED IN ANY FINISHED AREAS. 13. MAINTAIN CIRCUIT CONTINUITY FOR ALL EXISTING ITEMS THAT ARE REMAINING OR BEING RELOCATED. 14. PROVIDE UPDATED PANEL DIRECTORIES FOR ALL EXISTING PANELS BEING AFFECTED BY REMODEL WORK CIRCUIT NUMBERS SHOWN MAY NOT REFLECT ACTUAL FIELD CONDITIONS. PROVIDE NEW CIRCUIT BREAKER NUMBER IDENTIFICATION AS REQUIRED. 15. ALL ITEMS SHOWN TO BE REMOVED SHALL BE REMOVED IN THEIR ENTIRETY INCLUDING ALL ASSOCIATED CONDUIT AND WIRE BACK TO POINT OF ORIGIN OR NEAREST EXISTING ITEM THAT IS REMAINING, UNLESS OTHERWISE NOTED. 16. WHERE EXISTING DEVICES, SWITCHES, MOTOR CONNECTIONS, ETC. ARE TO BE REMOVED FROM WALLS WHICH ARE REMAINING, WALLS SHALL BE PATCHED TO MATCH ORIGINAL FINISH, AFTER CONDUCTORS HAVE BEEN REMOVED. BLANK COVERPLATES OVER EXISTING BOXES ARE NOT ACCEPTABLE. 17. IF EXISTING CONDUITS ARE ROUTED IN CONCRETE FLOOR SLABS, CONCRETE WALLS OR CONCRETE CEILINGS, THEY SHALL BE CUT BACK TO WITHIN CONCRETE AND FILLED WITH GROUT TO ACHIEVE A SMOOTH AND EVEN FINISH FLUSH WITH CONCRETE SURFACE AFTER CONDUCTORS HAVE BEEN REMOVED. www.brph.com Copyright © 2014 Architects, Engineers, Inc. 2727 Paces Ferry Road I Bldg 1 I Suite 1800 Atlanta I Georgia 1 30339 770-933-9242 1 770-933-9246 f Offices in Melbourne, Orlando, West Palm Beach, Atlanta, Charleston, Seattle These plans are protected by Federal Copyright protection. Unauthorized use may result in an infringement action. ISSUE FOR PERMIT AND CONSTRUCTION REVISION r In J M J LL. — W J J Z — O M W J = �— V Qom, w 1 � �w^ � J W Q N011. t� r ARCH/ENGR OF RECORD JOHN D. ADDISON FL PE #59239 DESIGNED BY JAH DRAWN BY JAH CHECKED BY JDA PROJECT NUMBER C06898.057.01 DATE 08/13/14 TITLE ELECTRICAL LEGEND DRAWING NO. 1 3 4 5 P ELECTRICAL PLAN NOTES THIS SHEET: E y y I�r a) C t 1 v 0 NI 0 am w JI LL I CL Na) I O LO A 0 co E 0 0 o 2 C 0 a. iu c co a) L 7 V) Q, cm Z) co TELCO BACKBOARD NOTES: O ® 0 GC TO INSTALL 2' LONG SHELF NEAR TOP OF PLYWOOD BACKBOARD FOR AT&T WI-FI AND NeN• N.Ns ...N. N.N. MUSIC EQUIPMENT; 1 DATA JACK TO TERMINATE AT MUSIC EQUIPMENT. NEW QUAD ELECTRICAL OUTLET, WITH DEDICATED 20 AMP CIRCUIT JUST BELOW OR NEXT TO TELCO BOARD. O3 3O 4'x4'x3/4" PLYWOOD TELCO BACKBOARD, LOCATED AT TELCO DEMARCATION POINT WITHIN SPACE. ® ALL CABLING TO TERMINATE WITH THE 48 PORT PATCH PANEL, TO BE LOCATED WITH TELCO BOARD. O5 TELEPHONE SERVICE ENTRANCE 05 CONDUIT AND CABLES ROUTE FROM ABOVE OR BELOW AS REQUIRED BY THE PARTICULAR INSTALLATION. O FINISH FLOOR TELCO BACKBOARD NTS PROVIDE 240V, 200A, 3 POLE HEAVY DUTY FUSED DISCONNECT TO 4 #3/0 (CU), #6G (CU), 21/2"C MATCH EXISTING BUILDING EXTERIOR TYPICAL OUTLET CONFIGURATION DETAILS AATV (TV WALL): PROVIDE CONDUIT FROM ACCESSIBLE CEILING TO COAX TERMINATIONS. ROUTE COAX CABLING TO MDF ROOM. [� I= NIGHT LIGHT o (1) COAX AND (2) DATA / DUPLEX RECEPTACLE + NIGHT LIGHT DUPLEX RECEPTACLE BCW (BACKWRAP) AND PTR (PRINTER): 0 0 O O O O (1) SWITCHED DUPLEX (1) DUPLEX RECEPTACLE FOR RECEPTACLE PRINTER FOR INTEGRATED (1) QUAD RECEPTACLE / (4) DATA / LIGHTING (1) TELEPHONE FOR PRINTER AND ADDITIONAL IT EQUIPMENT 1. WIRELESS ACCESS POINT. PROVIDE DATA FROM MDF BOARD WITH 25'-0" SERVICE LOOP FOR FINAL CONNECTION TO BE DETERMINED BY IT SURVEY 2. REFER TO ELECTRICAL SLAB PLAN, SHEET E500, FOR CONDUIT AND FLOOR BOXES SHOWN HERE IN SLAB. 3. SHOPPERTRAK SYSTEM. EXTEND TO MDF BACKBOARD. IN SALES AREA, COORDINATE EXACT LOCATION AND CABLING REQUIREMENTS WITH SHOPPERTRAK VENDOR PRIOR TO ROUGH -IN. 4. SHOWROOM RECEPTACLE SHALL BE FLUSH MOUNTED IN CEILING WITHIN 18" OF WINDOW PER NEC 210.62. 5. PROVIDE LIGHTING CONTROLS IN THIS ROOM. REFER TO LIGHTING CONTROL DETAIL ON SHEET E300. 6. NIGHT LIGHT. CONNECT NOTED DUPLEX OR NON -SWITCHED HALF OF QUADRUPLEX TO UNSWITCHED CONTINUOUSLY HOT CONDUCTOR OF CIRCUIT INDICATED FOR 24-HOUR OPERATION. 7. REFER TO OUTLET DETAILS THIS SHEET FOR AATV WALL DEVICE INFORMATION. REFER TO ARCHITECTURAL ELEVATIONS FOR DEVICE MOUNTING HEIGHTS AND LOCATIONS. 8. COORDINATE DEVICE MOUNTING LOCATIONS WITHIN CASEWORK WITH ARCHITECTURAL DETAILS, AT&T, AND CASEWORK INSTALLER. 9. DEVICES BEHIND WALL UNITS SHALL BE LOCATED PER ARCHITECTURAL. COORDINATE WITH ARCHITECTURAL PLANS PRIOR TO ROUGH -IN. 10. NOT USED. 11. UTILIZE EXISTING CONDUIT WITH PULLSTRING FROM BUILDING TELCO DEMARC POINT TO AT&T TENANT SPACE; EXTEND CONDUIT AS REQUIRED TO STUB OUT AT MDF BOARD. FIELD VERIFY EXACT LOCATION AND SIZE OF EXISTING CONDUIT AND COORDINATE REQUIREMENTS WITH AT&T AND LOCAL PHONE COMPANY. 12. NOT USED 13. EXTEND EXISTING CONDUIT FROM ROOF FOR FUTURE ROOF INSTALLED DEVICES (SATELLITE DISH, MUZAK, ETC.) AS REQUIRED TO STUB OUT AT MDF BOARD. FIELD VERIFY EXISTING CONDUIT LOCATION, AND COORDINATE EXACT REQUIREMENTS WITH OWNER. 14. SWITCHED RECEPTACLE FOR DISPLAY LIGHTS. FOR QUADRUPLEX RECEPTACLES, PROVIDE DUAL BRANCH CIRCUIT IN BOX WITH ONE CIRCUIT PER DUPLEX RECEPTACLE SWITCHED AS NOTED VIA SWITCHBANK AND ONE DUPLEX RECEPTACLE ALWAYS HOT AS INDICATED ON PLAN. DASH -DOT LINETYPE DENOTES SWITCHED CIRCUIT. PROVIDE BLACK ADHESIVE LABEL WITH 1/4" LETTERING NOTING "SWITCHED FOR LIGHTING" ON SWITCHED DUPLEX. 15. MOUNT WEATHERPROOF RECEPTACLES ON ROOFTOP UNITS. 16. PROVIDE 20Al2P MOTOR RATED SWITCH FOR CONNECTION TO ELECTRIC WATER HEATER. MOUNT SWITCH WITHIN SIGHT OF UNIT. 17. LIGHTING SWITCH BANK. LOWERCASE SUBSCRIPTS DENOTES SWITCH ZONE. 18. POWER FOR CONNECTION TO HAND DRYER. COORDINATE MOUNTING LOCATION WITH ARCHITECTURAL AND OWNER PRIOR TO ROUGH -IN. 19. INDOOR UNIT AC-1 IS POWERED FROM ROOFTOP UNIT CU-1. PROVIDE WIRING AND CONDUIT FROM ROOFTOP UNIT TO INDOOR UNIT AS REQUIRED. FIELD COORDINATE WITH MECHANICAL CONTRACTOR. 20. APPROXIMATE LOCATION OF EXISTING POWER AND TELCO EMPTY CONDUIT STUB -UPS. EXTEND NEW 2" CONDUIT TO PANEL A AND 1" TO BACKBOARD LOCATION. POWER SHEET NOTES: A. PROVIDE PULL STRING IN ALL EMPTY CONDUIT. B. REFER TO ARCHITECTURAL PLANS FOR EXACT LOCATION OF ALL POWER AND DATA OUTLETS. C. REFER TO AT&T STANDARDS FOR FLOORBOX SPECIFICATION. D. EXISTING METERING AND FEEDERS TO TENANT SPACE PANELBOARD ARE INTENDED TO REMAIN AS INSTALLED. CONTRACTOR SHALL FIELD VERIFY THAT EXISTING FEEDERS AND METERING IS IN GOOD WORKING CONDITION. IF NOT, REPLACE WITH EQUIVALENT NEW PRODUCT. E. PROVIDE ALL WIRING IN FULL COMPLIANCE WITH MOST CURRENT AT&T STANDARDS AS ALLOWED BY LOCAL CODES AND ORDINANCES. F. EXHAUST FAN EF-1 SHALL BE SWITCHED WITH LOCAL LIGHTING. NEW PANEL W. 4 #3/0 (CU), #6G (CU), 21/2"C TIE INTO EXISTING (TYPICAL). TENANT SPACE EXISTING (2) 21/2" EMPTY CONDUIT EXTEND ONE TO NEW DISCONNECT AND PANEL AS REQUIRED. 1 O o 0 0 (2) DATA FOR DIGITAL LIFE & EVERY OTHER MWU NON - SWITCHED IP (I -PHONE): o .o O DUPLEX RECEPTACLE / (2) DATA SWITCHED FOR I DISPLAY LIGHTING www.brph.com Copyright © 2014 Architects, Engineers, Inc. 2727 Paces Ferry Road I Bldg 1 1 Suite 1800 Atlanta I Georgia 1 30339 770-933-9242 1 770-933-9246 f Offices in Melbourne, Orlando, West Palm Beach, Atlanta, Charleston, Seattle These plans are protected by Federal Copyright protection. Unauthorized use may result in an infringement action. ISSUE FOR PERMIT AND CONSTRUCTION REVISION 0 r IV In M J ch — J Q LL. J W � J Z J ONN. N! N G Z o W 06 >_ J U) L.L. J W Q N c� 0 ARCH/ENGR OF RECORD JOHN D. ADDISON FL PE #59239 DESIGNED BY JAH DRAWN BY JAH CHECKED BY JDA PROJECT NUMBER C06898.057.01 DATE 08/13/14 TITLE DRAV41NG NO. E200 U 06 1 2 3 rd w ill E C f� LO A o rn co co a) E U 0 o 0o rL co (D c C0 a) d c w a)0 M) m EXISTING TO REMAIN LIGHTING�PLAND 2' 4' 8' 12' 1 LIGHTING FIXTURE SCHEDULE FIXTURE TYPE MANUFACTURER CATALOG NUMBER LAMPS DESCRIPTION Voltage F4A COOPER HALO L50516-20CMH-P-L111-LM5051 (1) 20W CMH CANOPY MOUNTED CMH MR16 MONOPOINT ACCENT 120 V STATIS 6-L973-AH CANOPY LIGHT, LOCKING TILT AND ROTATION, ON -OFF SWITCH, ALUMINIM DIE-CAST HOUSING WITH VERTICAL ELECTRONIC BALLAST, SOFT FOCUS LENS AND HOLDER, SQUARE MONOPOINT CANOPY ACCESSORY, ALUMINUM HAZE FINISH. F12 LITE ENERGY / LE/CS-44120-4XF25T8-120 (4) F25/T8 SPX35/ECO 48" DIAMETER LARGE SCALE SURFACE MOUNTED 120 V LIGHTOLIER LUMINAIRE WITH WHITE ACRYLIC DIFFUSER, 20 GAUGE DIEFORMED STEEL HOUSING, ELECTRONIC BALLAST(S), POLYESTER POWDER COAT MATTE WHITE FINISH. F16 COOPER METALUX (3) F32/T8 SPX35 VX4' RECESSED FLUORESCENT DIRECT LIGHT, HIGH 120 V GC332-UNV-EB81-U-1X4 MILK REFLECTANCE WHITE POWDER COAT PAINT FINISH, WHITE LEN FGW080 TEXTURED FRONT GLAZE ACRYLIC LENS, STANDARD FLANGE DESIGN WORKS WITH MOST LAY -IN CEILINGS. F16E COOPER METALUX (3) F32/T8 SPX35 SAME AS 'F16EXCEPT WITH EMERGENCY BATTERY 120 V GC332-120-FB P24H-EB81-U-1 X PACK. 4 MILK WHITE LENS FGW080 J1 LITHONIA 2GT8232Al2MVOLTGEB-101S (2) F32/T8 SPX35 2'X4' RECESSED/PRISMATIC 2 LAMP FLUORESCENT 120 V FIXTURE. J1E LITHONIA 2GT8232Al2MVOLTGEB-101S- (2) F32/T8 SPX35 SAME AS TYPE'J1' EXCEPT WITH INTEGRAL 1400 LUMEN 120 V EL1400 EMERGENCY BATTERY PACK; PROVIDE REMOTE TEST SWITCH IF REQUIRED BY LOCAL CODE CONTRACTOR SHALL VERIFY EXISTING EMERGENCY LIGHT FIXTURES PROVIDE ADEQUATE LIGHT TO PUBLIC WAY PER NFPA 101 EXISTING TO REMAIN FOR EXTERIOR SIGNAGE VIA SW "T LIGHT FIXTURE SCHEDULE NOTES: 1. VERIFY AND COORDINATE WITH ARCHITECT AND LIGHTING DESIGNER ALL FIXTURE MOUNTING DETAILS AND SIZES BASED ON FIELD CONDITIONS. 2. ALL FIXTURES SHALL BE UL OR ETL LISTED AND LABELED. 3. VERIFY FINAL FIXTURE SELECTION AND FINISHES WITH OWNER AND ARCHITECT. 4. ALL FIXTURES SHALL BE SUPPLIED WITH ALL NECESSARY FEEDS, CONNECTORS, ETC. FOR A COMPLETE INSTALLATION. 5. FIXTURES SHALL BE MOUNTED WITH LAMPS AND/OR REFLECTORS ORIENTED AS INDICATED ON DRAWINGS. 6. REFER TO ARCHITECTURAL DRAWINGS FOR ALL MOUNTING DIMENSIONS AND/OR DETAILS. ARCHITECTURAL DRAWINGS SUPERSEDE ALL OTHERS. 7. SUBMITTALS: AS PART OF THIS WORK THE CONTRACTOR SHALL, WITHIN 14 DAYS AFTER AWARD OF THE CONTRACT, SUBMIT A COMPLETE MATERIAL LIST OF ALL LIGHTING FIXTURES, LAMPS, MISCELLANEOUS MATERIALS, AND CONTROLS PROPOSED TO BE FURNISHED AND/OR INSTALLED. THIS SUBMITTAL SHALL INCLUDE MANUFACTURER'S SPECIFICATIONS, CUT -SHEETS, AND OTHER DATA REQUIRED TO DEMONSTRATE COMPLIANCE WITH THE SPECIFIED REQUIREMENTS. FURNISH THREE (3) BOUND COPIES 8-1/2" X 11". 8. NO SUBSTITUTIONS OF SPECIFIED FIXTURES, LAMP, OR CONTROL MANUFACTURER WILL BE ACCEPTABLE WITHOUT SPECIFIC PRIOR WRITTEN APPROVAL OF THE ARCHITECT AND LIGHTING DESIGNER. IF CONTRACTOR OR DISTRIBUTOR MAKES A SUBSTITUTION WITHOUT SAID PRIOR APPROVAL, CONTRACTOR OR DISTRIBUTOR SHALL REPLACE THE SUBSTITUTED ITEM WITH THE SPECIFIED ITEM AND SHALL BEAR ALL ASSOCIATED COSTS (INCLUDING BUT NOT LIMITED TO THE ARCHITECTS AND/OR LIGHTING DESIGNER'S LABOR COSTS INVOLVED IN RE -AIMING FIXTURES, TRAVELING TO THE SITE, ETC.) WITHOUT ANY ADDITIONAL CHARGE TO THE OWNER. 9. FINAL AIMING SHALL BE PERFORMED BY THE CONTRACTOR UNDER DIRECTION OF THE OWNER AND LIGHTING DESIGNER. 10. PROVIDE ALL EXIT SIGNS REQUIRED FOR THIS PROJECT. THIS SHALL INCLUDE ALL EXIT SIGNS SHOWN ON THE PLANS AND ANY ADDITIONAL EXIT SIGNS THAT MAY BE REQUIRED BY THE LOCAL JURISDICTION. THIS CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING WITH THE JURISDICTION THE REQUIRED LENS COLOR FOR EXIT SIGNS AND THE REQUIRED QUANTITY AND LOCATIONS FOR EXIT SIGNS. 11. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LIGHTING LOCATIONS. 12. CONTRACTOR SHALL BE RESPONSIBLE FOR THE COMPLETE INSTALLATION OF LIGHT FIXTURES, INCLUDING BUT NOT LIMITED TO PROVIDING ALL SUPPORTS, CLIPS, POWER CONNECTIONS, AND SEISMIC BRACING AS REQUIRED BY THE LOCAL JURISDICTION. 13. REMOTE HEADS SHALL BE TIED TO SEPARATE HEADLESS BATTERY PACK. GENERAL LIGHTING NOTES: A. FIXTURES DESIGNATED WITH "E" -or- "EXISTING" ARE EXISTING TO REMAIN. FIXTURES DESIGNED WITH'R' ARE EXISTING FIXTURES TO BE RELOCATED WITHIN GRID. ALL EXISTING AND RELOCATED FIXTURES SHALL BE CLEANED, RELAMPED, AND INSPECTED FOR GOOD WORKING ORDER. ANY FIXTURES NOT IN GOOD CONDITION SHALL BE REPLACED WITH SIMILAR FIXTURE. B. ALL LAMPS SHALL BE FULL -LIGHT, HIGH -EFFICIENCY ENERGY -SAVING TYPE. C. PENDANT, RECESSED, AND SURFACE MOUNTED FIXTURES SHALL BE SUPPORTED FROM THE STRUCTURE, NOT FROM CEILING GRID. D. CONTACT GRAINGER FOR ALL LIGHT FIXTURE ORDERS, SEE BELOW FOR CONTACT INFORMATION: ANDREW DODSON GRAINGER (404) 806-8263 E. REFER TO SHEET E300 FOR LIGHTING FIXTURE SCHEDULE. F. REFER TO ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT LIGHTING FIXTURE LOCATIONS. LIGHTING NOTES THIS SHEET: 1. CIRCUIT EMERGENCY LIGHTING BATTERY PACKS AND EXIT SIGNS AHEAD OF LOCAL SWITCHING FOR CONTINUOUS OPERATION. PROVIDE SEPARATE UNSWITCHED CONDUCTOR. ALL EMERGENCY LIGHTS AND EXIT SIGNS SHALL BE CIRCUITED WITH LOCAL LIGHTING CIRCUITS IN SAME AREA PER NEC. 2. NIGHT LIGHT. CIRCUIT FIXTURES SHOWN AHEAD OF LIGHTING CONTROLS FOR CONTINUOUS OPERATION. 3. EXHAUST FANS SWITCHED WITH LIGHTS. 4. MATCH EXISTING EXIT SIGN FOR BRAND, MODEL, VOLTAGE, COLOR OF FACES, ETC, 5. LIGHTING SWITCH BANK. LOWERCASE SUBSCRIPT DENOTES SWITCH ZONE. www.brph.corn Copyright © 2014 Architects, Engineers, Inc. 2727 Paces Ferry Road I Bldg 1 1 Suite 1800 Atlanta I Georgia 1 30339 770-933-9242 1 770-933-9246 f Offices in Melbourne, Orlando, West Palm Beach, Atlanta, Charleston, Seattle These plans are protected by Federal Copyright protection. Unauthorized use may result in an infringement action. ISSUE FOR PERMIT AND CONSTRUCTION REVISION Z�, 7 J L 0 U) J J ■■ TF 7 ARCH/ENGR OF RECORD JOHN D. ADDISON FL PE #59239 DESIGNED BY JAH DRAWN BY JAH CHECKED BY JDA PROJECT NUMBER C06898.057.01 DATE 08/13/14 TITLE LIGHTING DRAWING NO. C�Ic�iI�7 Z O V W ry w U) PLAN 6 U 00 1 N 3 4 I 5 Cl E c C 13 6 am v c 0 Nr U m w Jr U_ �r s a Na) 0 A LO o M rn co cD co E U 0 o� C D 0 c CO a N co O m U co o Panel. A (NEW) Design Selection: Voltage: 120/208 Wye Minimum A.I.C. Rating: 35K Mains: 200 A Phases: 3 Location: ELEC 103 Type: MCB Wires: 4 Served From: UTILITY Mounting: Surface Modifications: Trip Trip Note Amps Poles Description Wire Neut Gnd Cond No. A B C No. Cond Grid Neut Wire Description Poles Amps Note 20 A 1 Receptacle #12 #12 #12 1/2" 1 1.1 kVA 0.7 kVA m 2 1/2" #12 #12 #12 Receptacle 1 20 A 20 A 1 Receptacle #12 #12 #12 1/2" 3 1.1 kVA 0.7 kVA x 4 1/2" #12 #12 #12 Receptacle 1 20 A 20 A 1 Receptacle #12 #12 #12 1/2" 5 1.1 kVA 0.2 kVA 6 1/2" #12 #12 #12 Receptacle 1 20 A 20 A 1 Receptacle #12 #12 #12 1/2" 7 0.9 kVA 0.7 kVA e.20 8 1/2" #12 #12 #12 Receptacle 1 20 A A 1 Receptacle #12 #12 #12 1/2" 9 0.7 kVA 0.7 kVA ,,. 10 1/2" #12 #12 #12 Receptacle 1 20 A 20 A 1 Receptacle #12 #12 #12 1/2" 11 0.7 kVA 0.2 kVA 12 1/2" #12 #12 #12 Receptacle 1 20 A 20 A 1 Receptacle #12 #12 #12 1/2" 13 0.2 kVA 0.3 kVA „ ;° 14 1/2" #12 #12 #12 Lighting 1 20 A 20 A 1 Lighting #12 #12 #12 1/2" 15 1.0 kVA 0.4 kVA 16 1/2' #12 #12 #12 Phone Recept 1 20 A 20 A 1 Store Sign #12 #12 #12 1/2" 17 0.5 kVA 0.4 kVA 18 1/2" #12 #12 #12 Roof Recept 1 20 A 20 A 1 Lighting #12 #12 #12 1/2" 19 0.5 kVA 2.9 kVA,_ ," 20 20 A 1 Lighting #12 #12 #12 1/2" 21 °; .' % 0.4 kVA 2.9 kVA - , , , 22 1 1/4" #8 #3 #3 RTU-1 3 80 A 20 A 1 AC-1/CU-1 #12 #12 #12 1/2" 23 0.9 kVA 2.9 kVA 24 20 A 1 Hand Dryer #12 #12 #12 1/2" 25 1.7 kVA 1.5 kVA 26 1/2" #12 #12 #12 Elec Water Heater 2 20 A - 20 A 1 Spare -- - - - 27 0.0 kVA 1.5 kVA 28 - 20 A 1 Spare - - - - 29 0.0 kVA 0.0 kVA 30 - - - - Spare 1 20 A - - 20 A 1 Spare - - - - 31 0.0 kVA 0.0 kVA 732 - - - - Spare 1 20 A - - 20 A 1 Spare - - - - 33 0.0 kVA 0.0 kVA 34 - - - - Spare 1 20 A - - 20 A 1 Spare - - - - 35 0.0 kVA 0.0 kVA 36 - - - - Spare 1 20 A - - 20 A 1 Spare - - - -- 37 0.0 kVA 0.0 kVA 38 - - - - Spare 1 20 A - - 20 A 1 Spare - -- - -- 39 0.0 kVA 0.0 kVA a>' h 40 - - - - Spare 1 20 A - - 20 A 1 Spare - - - - 41 0.0 kVA 0.0 kVA 42 - - - - Spare 1 20 A - Total 10.5 kVA 9.3 kVA 6.8 kVA Load Classification Connected Load Demand Factor Demand Load Load Summary HVAC 12.62 kVA 100.00% 12.62 kVA Total Connected Load: 26.6 kVA Lighting 2.60 kVA 125.00% 3.25 kVA Receptacle 11.42 kVA 93.78% 10.71 kVA Estimated Demand Load: 26.6 kVA Notes: 1. All breakers indicated as "Spare" shall be in the "OPEN" (OFF) position. 2. Contractor shall field verify the required AIC rating of the panel breakers and modify as required. Total Estimated Demand Current:174 A ELECTRICAL SPECIFICATIONS SECTION 16000 3.2 GROUNDING 2.5 LIGHTING FIXTURES 1. Service equipment, conduit systems, supports, cabinets, equipment, PART 1 GENERAL A. Provide all new lighting fixtures complete with lamps, ballasts, reflectors, transformers, fixtures, the grounded circuit conductor, etc., shall be plaster frames, louvers, stem hangers, etc., and as described on the drawings. properly grounded in accordance with the latest issue of the National 1.1 CODES AND REQUIREMENTS Electrical Code. Provide all bonding jumpers and wire, grounding A. All electrical work shall comply with the requirements of the applicable B. All ballasts shall be internally protected by use of two internal, bushings, damps, etc., as required for complete grounding. Route edition of the National Electrical Code, Local Building Code and as temperature -sensitive, non -resetting protectors, equal to G.E. Watt -Miser, ground conductors to provide the shortest and most direct path to specified herein whichever is more strict Class "P" the ground electrode system. Ground connections shall have dean contact surfaces, tinned and sweated while bolting. Install all ground B. The contractor shall comply with the requirements of the General C. Exit and emergency lights shall conform with local code requirements. conductors in conduit. Make readily accessible connections to a continuous, metallic, underground cold water piping system at the Conditions, Supplemental General Conditions of the project specifications, point where it enters the building. If this is not practical, connect to all Contract Documents, and any base building specifications and building D. Mount all outlets at position and height to dear ducts, etc. a cold water pipe and provide a meter jumper. Make connections to aiteria included in this project. the water pipe that grounds the conduit enclosing the conductor as E. Acrylic lenses shall be 100% virgin materials and 0.125 inch thick; well as the conductor. Bond the service equipment to building steel, C. Visit the premises before submitting bid as no extras will be allowed for lack minimum unpenetrated thickness shall be 0.035 inch. concrete encased electrodes, underground metal water piping, driven of knowledge of existing conditions. electrode, and all other available grounding electrodes per NEC article 2.6 BRANCH CIRCUIT PANELBOARDS 250. D. Drawings are diagrammatic in nature. Take ail dimensions from Architectural A. Provide dead -front, circuit breaker type panels, with the size and number drawings, certified equipment drawings, and from the structure itself before of branches indicated. Breakers shall be thermal magnetic type fabricating any work. employing quick -make and quick -break mechanisms for manual operation 3.3 PANELBOARDS as well as automatic operation. Automatic tripping shall be indicated by the 1. Install panelboards with the top of the trim six -feet, three -inches E. The drawings indicate the location, type and sizes of various utilities within the breaker handle assuming a distinctive position from the manual "on" and "off'. (6-Y) from the finished floor. site where known. Any relocation or remodeling required must be approved Multiple breakers shall have a common trip. Tie handles will not be permitted. by the Architect before proceeding. Investigate all utilities such as electric and 2. Field check all panelboard loading and reconnect circuits as telephone and make arrangements with the proper authority to pay for any B. Panelboards having branch circuit breaker sizes 15 to 100 amperes shall be: required to provide balanced phase and line loads. charges associated with connecting those utilities. Pay for all permits, fees, 1. General Electric "AQ" for operation on 120/208V. systems. inspections etc. 2. General Electric "AE" for operation on 277/480V. systems. 3.4 MECHANICAL EQUIPMENT WIRING AND CONNECTIONS 1. Mechanical equipment motors and controls furnished with F. Good workmanship and appearance are considered equal to proper operation. C. Panelboards may contain two (2) subfeed breakers having a rating in excess mechanical equipment. of 100 amperes, but less than 225 amperes. G. Provide all core drilling, channeling, cutting, patching, trenching and backfill as 2. Provide feeder circuits to mechanical equipment and make required for installation of electrical equipment. Seal holes, fireproofing where D. Panelboards having more than two (2) branch circuit breakers rated in all connections. necessary, and refinish all repair work to original condition where damaged by excess of 100 amperes shall be General Electric "Spectra" series. electrical work. 3. Provide safety switches and/or thermal overload swatches as E. All spaces shall be fully equipped. required. H. Make provisions for safe delivery and secure storage of all materials. F. Panelboards shall have a grounding lug for the equipment grounding system. 4. Provide all power (line voltage) wiring for mechanical equipment I. Provide the Architect with a complete set of plans and specifications corrected and make all connections except for temperature control to as -built conditions at the completion of the job. G. Circuit breakers shall have a minimum interrupting capacity as follows: equipment, which will be wired by mechanical contractor. 1.2 WARRANTY 120/208 volts: 22,000 amperes. 5. Furnish, set in place, and wire, except as indicated, all heating, The electrical contractor shall provide for the owner a one-year (from the date of final In addition, upstream fuses shall be selected to provide a series rating ventilating, air conditioning, plumbing, fire protection, motors and acceptance) warranty of all electrical equipment and systems provided under this contract of 100,000 amperes with downstream circuit breakers. controls in accordance with the following schedule. Carefully except for incandescent or fluorescent lamps. All defective equipment or materials which coordinate with work performed under the Mechanical Division appear during the warranty period shall be replaced or repaired by the electrical contractor H. Panelboards shall be a minimum twenty inches (20") wide (box). of these specifications. in a timely fashion. I. All buses shall be copper. 6. Heater units in all motor starters shall be sized for approximately e one hundred fifteen percent (115%) of full load motor current. J. The above panelboard designations are General Electric; however provide Check and coordinate all thermal protective devices with the PART 2 PRODUCTS any of the following equipment: Cutler Hammer, General Electric, equipment they protect. Siemens, or Square D. 2.1 EQUIPMENT a) Provide for each motor, one-half (1/2) horsepower and below, A. The contractor shall provide all equipment and accessories necessary whether a horsepower rated disconnect switch and thermal overload specifically stated or not to make the required electrical systems complete and 2.7 SAFETY AND DISCONNECT SWITCHES protection unless integrally provided with the motor. Thermal operational. Provide enclosed, fusible or non -fusible safety switches. where overload switches for single phase motors shall be Allen-Bradley specified. Safety switches shall bear the UL indicated and herein speci Bulletin 600 or acceptable. Size heater units for approximately B. All equipment provided shall be new except as otherwise stated on the drawings. label and each enclosure shall be the NEMA type suitable for the one- hundred fifteen percent (115%) of full load motor current. All equipment provided shall be U.L. listed when such standards exist for the type surrounding area and conditions. Switches shall be minimum heavy of equipment furnished and acceptable for installation by the Local Building Authority. duty, horsepower rated, and shall have quick -make and quick -break b) Miscellaneous Equipment: Where outlets are indicated for mechanisms. Switches used on motor circuits shall have adequate miscellaneous equipment requiring electric power or control, 2.2 CONDUCTORS horsepower ratings for the motors served. provide wire, conduit, etc., and make all connections, unless A. Minimum size #12 AWG except for control circuits which may be #14 or signal otherwise indicated. Refer to the Mechanical Specifications and circuits which shall be as indicated. All conductors shall be copper. Increase 1. Safety switches employed as motor disconnect devices for two (2) Plans covering sprinkler systems, motor interlocks, switching, etc. conductor size as necessary to limit branch circuit voltage drop to 3% and feeder or more loads shall be of the fusible type for rejection type fuses. Provide wiring, conduit, outlets and provide final electrical voltage drop to 2%. connections to all equipment. 2. Heavy duty industrial type safety switches shall be used B. Splices for #8 and smaller conductors - wire or wing nuts. and shall be horsepower rated with quick -make, quick -break 3.7 TELEPHONE SYSTEM mechanisms and interlocked covers. A. Provide conduits and outlets as indicated. Provide #14 AWG C. Feeders and other wiring No. 4 AWG and larger, type THWN. 3. Switches shall be as manufactured by Cutler -Hammer, General pull wire for all empty conduit D. Other wiring No. 6 and smaller, type THWN. Electric, Square-D, or Siemens, and all switches provided shall be by the same manufacturer. B. Outlets shall consist of 4" square box with bushed opening in plate. Plates shall match finish of other plates. E. Wiring in high temperature areas shall be rated 105°C and be a type accepted by local code. PART 3 EXECUTION 3.8 SPECIAL SYSTEMS 1. Provide all special systems as specified on the drawings F. Color Coding: Wiring for control systems to be installed in conjunction with 3.1 CONDUIT/RACEWAYS including all required accessories to make the system complete mechanical and miscellaneous equipment shall be color coded in accordance A. All conductors shall be enclosed by conduit sized in accordance with and operational. All special systems shall be installed and with the wiring diagrams furnished with the equipment Branch circuit wiring, the National Electrical Code. Minimum 3/4" except for connected in accordance with the manufacturer's specifications. including circuits to motors, and all feeders shall be coded by line or phase as factory furnished lighting fixture flexible conduit may be 3/8". Follow the Provide instructional demonstration for the owner prior to final follows: following schedule unless otherwise specified in the drawings. acceptance. 1. Rigid metal conduit (RMC) and intermediate metal conduit (IMC) Wire No. 2 AWG and smaller shall be factory color coded. Wire No.1 AWG shall be utilized for above and below grade applications in accordance 3.9 SEISMIC RESTRAINTS and larger may be color coded by field painting or color taping of sic inch (T) with articles 344 AND 342 of the National Electrical Code. All couplings 1. Provide seismic restraints for all electrical equipment and system length of exposed ends. shall be threaded. components as required by local codes. 120/208 Volts 2. Rigid nonmetallic conduit (PVC) Schedule 40 shall be permitted A = Black for below grade or concrete cast in place applications above grade. END OF SECTION B = Red All elbow transitions to above grade or stub -out of floor slab shall be C = Blue asphalt coated rigid conduit. Provide equipment grounding conductor Neutral = White for all runs of rigid nonmetallic conduit. Ground = Green Switch Travelers = Pink 3. Electrical metallic tubing (EMT) shall be utilized for all dry, above grade or above floor applications in accordance with article 358 of the National 2.3 OUTLETS Electrical Code. Couplings shall be steel compression type made up A. 4" square or octagonal, zinc coated sheet steel boxes. wrench -tight. B. Provide 3/8" no -bolt fixture studs. 4. Flexible metal conduit shall be utilized for all connections to vibrating equipment such as motors (minimum of 2'-0" - maximum of 6-0"), C. Provide covers set to come flush with finish walls. connection to lay -in type light fixtures or in remodel areas specifically noted for "fishing" in existing walls or non -accessible ceilings. D. Utility or sectional switch boxes only where permitted. 5. Surface metallic raceways shall be used only in areas specifically 2.4 DEVICES noted and of size and type specified on the drawings. A. All devices colors shall be white. 1. Specification grade receptacles, equal to Hubbell 5362 NEMA 5-20R. 6. Metal -Clad Cable (MC) may be utilized for all dry, concealed, above grade 2. A.C. quiet operating type switches equal to Hubbell, rated 20A, 277V. applications only within tenant space and not crossing any fire or rated B. Device plates shall be nylon, color to match devices. barriers. Install cable in accordance with article 330 of the National C. Mount devices in accordance with the following schedule except where Electrical Code. otherwise noted on the drawings: B. All exposed conduit (including conduit installed in ceiling plenums) 1. Convenience Receptacles - Long Axis Vertical IV' A.F.F.* shall be routed parallel or perpendicular with the building walls. 2. Light Switches - Latch Side of Door 4V A.F.F. Support conduit as required by the National Electrical Code. 3. Telephone Outlets VT A.F.F.* * Except in areas with counters, baseboard heaters or in areas of block or bride construction. C. Provide expansion type fittings for all conduits which cross expansion joints. www.brph.com Copyright © 2014 Architects, Engineers, Inc. 2727 Paces Ferry Road I Bldg 1 1 Suite 1800 Atlanta I Georgia 1 30339 770-933-9242 1 770-933-9246 f Offices in Melbourne, Orlando, West Palm Beach, Atlanta, Charleston, Seattle These plans are protected by Federal Copyright protection. Unauthorized use may result in an infringement action. ISSUE FOR PERMIT AND CONSTRUCTION REVISION - M O c J w J T r In M J I J J - N1 Z - w ,�x� W o/ � 0- w N • � J a c� Uw^ r ARCH/ENGR OF RECORD JOHN D. ADDISON FL PE #59239 DESIGNED BY JAH DRAWN BY JAH CHECKED BY JDA PROJECT NUMBER C06898.057.01 DATE 08/13/14 TITLE ELECTRICAL SPECIFICATIONS DRAWING NO. E400 1 N K 4 5 6 '_'�--- h e f, E C F. a) N� 0 Ln A 0) co co E U 0 o� Cn co ar C cM m N r co O 1 El €mm� ...... ELECTRICAL POWER AND DATA SLAB WORK PLAN 1 /4" = 1'-0" 0 2' 4' 8' 12' 1 /4" = 1'-0" GENERAL ELECTRICAL POWER AND DATA SLAB WORK PLAN NOTES: 1. WIREMOLD FLOOR BOXES AS SHOWN WITH FLUSH COVER. CIRCUIT AS SHOWN ON POWER PLAN. COORDINATE EXACT LOCATION WITH OWNER AND ARCHITECT PRIOR TO SLAB CUT -IN. FLOOR BOXES FOR EXPERIENCE TABLES SHALL BE AS FOLLOWS: QUAD OUTLET: 881 MULTIPLE SERVICE FLOOR BOX WITH RC4ATCBK COVER KIT DUPLEX OUTLET: 881 MULTIPLE SERVICE FLOOR BOX WITH CTCBK COVER KIT 2. ROUTE CONDUIT IN SLAB UNDER FLOOR TO NEAREST WALL THAT EXTENDS FROM FLOOR TO ABOVE CEILING (NOT A SHORT WALL) AND ROUTE UP WITHIN WALL. 3. REFER TO ARCHITECTURAL PLANS FOR FLOOR BOX DIMENSIONED LOCATIONS. www.brph.com Copyright © 2014 Architects, Engineers, Inc. 2727 Paces Ferry Road I Bldg 1 1 Suite 1800 Atlanta I Georgia 1 30339 770-933-9242 1 770-933-9246 f Offices in Melbourne, Orlando, West Palm Beach, Atlanta, Charleston, Seattle These plans are protected by Federal Copyright protection. Unauthorized use may result in an infringement action. ISSUE FOR PERMIT AND CONSTRUCTION REVISION Ln M J M — J - LLJ J J Z m O J = 0 J_ �. N w W 06 >- ; F'— Q = m � J W Q N 0 0 v- ok. ARCH/ENGR OF RECORD JOHN D. ADDISON FL PE #59239 DESIGNED BY JAH DRAWN BY JAH CHECKED BY JDA PROJECT NUMBER C06898.057.01 DATE 08/13/14 TITLE ELECTRICAL SLAB PLAN DRAWING NO. U co 1 2 3 n 5 I 6 a 0 :7