Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
7950-7944 Gall Blvd
GENERAL NOTES: - ALL WORK SHALL CONFORM TO THE CURRENT EDITION OF THE FLORIDA BUILDING CODES, AND ALL OTHER GOVERNMENTAL OR REGULATORY AUTHORITIES. - GENERAL CONTRACTOR AND ALL SUBCONTRACTORS TO VERIFY ALL DIMENSIONS IN THE FIELD. ANY DISCREPANCIES SHALL BE REPORTED TO THE ARCHITECT PRIOR TO PROCEEDING WITH THE WORK DO NOT SCALE PLANS. - THE CONTRACTORS SHALL BE RESPONSIBLE FOR FAMILIARIZING THEMSELVES WITH THE INTENT OF THE DRAWINGS. CONTRACTOR AGREES THAT HE SHALL BE HELD RESPONSIBLE FOR HAVING EXAMINED THE SITE. THE LOCATION OF ALL PROPOSED WORK AND FOR HAVING SATISFIED HIMSELF, AS TO THE CHARACTER AND THE NATURE OF THE EXISTING CONDITIONS AND WORK TO BE PERFORMED* ALONG WITH THE LOCATION OF EXISTING UTILITIES AND ANY OTHER OBSTRUCTIONS. - IT SHALL BE THE RESPONSIBILITY OF ALL SUBCONTRACTORS TO HAVE EXAMINED AND REVIEWED THE COMPLETE SET OF WORKING DRAWINGS AND/OR SPECIFICATIONS TO PROVIDE ALL LABOR AND MATERIALS FOR THEIR RESPECTIVE AREA OF WORK, FOR THE COMPLETE AND FINISHED INSTALLATION IN COMPLIANCE WITH THE INTENT OF THE DRAWINGS AND/OR SPECIFICATIONS WHETHER IT IS INDICATED OR NOT. ALL WORK, WHETHER INDICATED OR NOT, SHALL BE IN COMPLIANCE WITH ALL BUILDING CODES AND ORDINANCES WHICH ARE APPLICABLE TO THE PROJECT. - CONTRACTOR TO PROVIDE ALL BARRICADES, SCAFFOLDING, SIGNS, LIGHTING AND OTHER MEANS OF PROTECTION AS REQUIRED TO COMPLY WITH ALL STATE LAWS AND LOCAL ORDINANCES TO SAFEGUARD PROPERTY AND PERSONS. OBSTRUCTIONS SHALL BE PLACED SO AS NOT TO DIMINISH THE LIFE SAFETY REQUIREMENTS. - ALL WORK SHALL BE PERFORMED BY QUALIFIED CONTRACTORS IN STRICT ACCORDANCE WITH MANUFACTURERS SPECIFICATIONS AND RECOMMENDATIONS. - ALL MATERIAL AND EQUIPMENT SHALL BE NEW, STORED AND INSTALLED IN A WORKMANLIKE MANNER STANDARD TO THE TRADE AND THE AMERICAN SOCIETY OF TESTING MATERIALS. - THE DESIGN INFORMATION INDICATED ON THE PLANS ARE INDICATED TO BE A COMPLETE AND WORKABLE SYSTEM IN ACCORDANCE WITH ALL PRODUCT MANUFACTURER'S SPECIFICATIONS, EXISTING AND/OR PROPOSED BUILDING DESIGN, FIELD CONDITIONS, ETC. ALL MISCELLANEOUS MATERIALS, PARTS, DESIGN DIMENSIONS, WHETHER INDICATED ON THE PLANS OR NOT, SHALL BE INCLUDED AS PART OF THIS DRAWING PACKAGE. - THE GENERAL CONTRACTOR OR SUBCONTRACTORS SHALL BE HELD RESPONSIBLE FOR THE REMOVAL AND THE PROPER DISPOSAL OF MATERIALS AND ITEMS REFERRED TO AS "DEBRIS" OR DETERMINED BY THE OWNER OR ARCHITECT TO BE REFUSED. - THE GENERAL CONTRACTOR SHALL HAVE MADE ALL REQUIRED PROVISIONS FOR THE REMOVAL OF THE DEBRIS ON SITE. - GENERAL CONTRACTOR SHALL TAKE ORDINARY PRECAUTIONS TO SECURE AND PROTECT MATERIALS. - ALL WOOD MEMBERS IN CONTACT WITH MASONRY SHALL BE PRESSURE TREATED. - ALL METAL USED FOR CONNECTING WOOD MEMBERS TO BE GALVANIZED OR CORROSION RESISTANT. - THE ARCHITECT SHALL NOT BE RESPONSIBLE FOR ANY DEVIATION FROM THESE DRAWINGS. - SPECIFIC SECTIONS, DETAILS AND STANDARD DETAILS ARE INDICATED ON THE DWGS AT LOCATIONS WHERE THEY OCCUR, OR AT CHARACTERISTIC LOCATIONS. THEY APPLY, UON, TO OTHER LOCATIONS WHERE IMPLIED BY SIMILARITY OF CONSTRUCTION. - CONTRACTOR TO COORDINATE SPACE REQUIREMENTS AND INSTALLATION OF MECHANICAL AND ELECTRICAL WORK WHICH ARE INDICATED DIAGRAMMATICALLY ON THE DRAWINGS. FOLLOW ROUTING SHOWN FOR PIPES, DUCTS, AND CONDUIT AS CLOSELY AS PRACTICABLE. PLACE RUNS PARALLEL WITH LINE OF BLDG. UTILIZE SPACES EFFICIENTLY TO MAXIMIZE ACCESSIBILITY FOR OTHER INSTALLATIONS AND FOR MAINTENANCE AND REPAIRS. - IN FINISHED AREAS, ION, CONCEAL PIPES, DUCTS, AND WIRING WITHIN THE CONSTRUCTION. COORDINATE LOCATIONS OF FIXTURES AND OUTLETS WITH FINISH ELEMENTS. - TRANSPORT AND HANDLE PRODUCTS IN ACCORDANCE W/ MFR INSTRUCTIONS. - PROMPTLY INSPECT SHIPMENTS TO ASSURE THAT PRODUCTS COMPLY W/ REQUIREMENTS, QUANTITIES ARE CORRECT, AND PRODUCTS ARE UNDAMAGED. - SHOULD MFR INSTRUCTIONS CONFLICT W/ THE DWGS, REQUEST CLARIFICATION FROM ARCHITECT/ENGINEER BEFORE PROCEEDING. - ALL THRESHOLDS SHALL COMPLY WITH FLORIDA ACCISSIBILITY CODE, 4.138 AS FOLLOWS: A. THRESHOLDS NOT TO EXCEED 3/4 INCH FOR EXTERIOR SLIDING DOORS. B. THRESHOLDS NOT TO EXCEED 1/2 INCH HEIGHT FOR OTHER DOOR TYPES. C. RAISED THRESHOLDS AND FLOOR LEVEL CHANGES AT ACCESSIBLE DOORWAYS SHALL BE BEVELED WITH A SLOPE NO GREATER THAN 1:2. - G.G. SHALL FURNISH AND INSTALL CONT. WOOD BLOCK'G IN STUD PARTITIONS FOR ANCHORAGE OF WALL ATTACHED ITEMS, INCLUDING BUT NOT LIMITED TO THE FOLLOWING: GRAB BARS, TOILET ACCESSORIES, HANDRAIL BRACKETS, WALL CABINETS, WALL -MOUNTED FIXTURES ETC- - THE OWNER SHALL BE RESPONSIBLE FOR PROVIDING THE CONTRACTOR W/ ROUGH -IN INFO. NECESSARY TO ACCOMODATE THE INSTALLATIONS OF OWNER FURNISHED AND INSTALLED ITEMS. - THE CONTRACTOR SHALL INCLUDE ALL OWNER FURNISHED AND INSTALLED ITEMS IN THE CONSTRUCTION SCHEDULE, AND SHALL COORDINATE W/ THE OWNER TO ACCOMODATE THESE ITEMS. - COORDINATE ALL DEMOLITION EFFORTS W/ THE OWNER EVERY EFFORT SHALL BE MADE TO MINIMIZE DISRUPTION OF OPERTATION AND TO PROVIDE PATRON SAFETY. EXCESSIVE NOISE OR VIBRATION SHALL BE PRE -APPROVED AND COORDINATED W/THE OWNER - COORDINATE W/ THE OWNER THE PRE -APPROVED DISRUPTION AND VERIFICATION OF SERVICE WITHIN THE EXISTING BUILDING SO AS TO MINIMIZE THE DISRUPTION OF SERVICE. - CONSTRUCT TEMPORARY CONSTRUCTION PARTITIONS WITHIN THE EXISTING BUILDING WHICH OFFER AN ENCLOSURE TO ISOLATE ANY DEMOLITION/ CONSTRUCTION WORK FROM THE GENERAL PUBLIC AND AS DEEMED NECESSARY BY THE OILIER ABBREVIATIONS: A M AS ANCHOR MOLT MSS MASONRY AMV ABOVE MATL MATERIAL AC ACC06OPM MAX MAXIMUM AEG AIR CONDITIONING MC MEDICINE CABINET ACF AOCE86 FL.00RSI'G ACT ACOUSTICAL CEILING TILE MECH MECHANICAL AD AREA DRAM MiR MANFAC URRR ADD ADDENDUM ADAACE NT MID MIDDLE ADJ ADJWTADLE MN MMMUM AFF AMOVE FINISH FLOOR MISC MSCELLAHEOW NHU AIR HANDLING, WIT ML MATCH INE ALT ALTERNATE MLDG MOULDING ALUM ALUMINUM MO MASONRY OPENING ANOD ANODIZED MODF MODFIED AP ACCESSPAIB Mm MOWTEDI(MW APPROX AIYROXIUTE MCI MOUNTING ACH AIRCFI1ECMIRI 1(Ult4L.) MTL METAL ASPH ASPHALT MILL MULLION AUTO AUTOMATIC MW MILLWORK AUK AUXILIARY AVG AVERAGE NUT ACOUSTICAL. WALL TREATMENT AN MININGN N NORTH B NA NOT APPLIGIMI E NIC NOT N CONTRACT OF 04OOLD NO Nil" am MELON RNISHED FLOOR NOM NOISMN MR)MINM BWTMINOUS NRC NOISEISCIIIAREFION OLD BOLLARD NSF NET FOOTAGE FOOTAGE aux BIUWDNG Nfb TO CA NOT TO SCALE MLK(w RM.oaaG ISLW BELOW MM BEAN ISOC+MNac o ON mNCH OA OVERALL 115PAW mwx OC ON CENTER am BOARD OD OUTSIDE DIAMETER DRG BEARING OF OUTSIDE FACE aw ISRAOW OH OVERHEAD MS BOTH SIDES OPHDD oPPOORE HAND UN MOTTOM OPNG OPENING MIN ft-T EE7N OPP OPPOSITE BUR MILT-WJP ROOF MVL BEVELLED P C IOU PLASTIC Comm GUARD CAM CAMNET PED PEDASTN.ISTAIND CAP CAPACITY PL PLROIPEm LINE CIS CATCH ISASN/ COVE "N PLAM PLASTIC LAMNATE C+c CENTER TO CENTER PLAS PLASTIC GEM CEMENT PLWD PLYWOOD CER CERAMIC MIL PANE. CG CORNER GUARD PNT PANT CI CAST WN FM POLISHED CJ CONTROL JOINT IPR PAIR CLG CEILING PRT PARTITION CLR CLEAR PSI POUNDS PER SQUARE NCH CLOT CLOSET PT POINT CM GROAN MOW.DMG PTD/D PAPER TOWEL DO ENS1"SPOSAL cm CONCRETE MASONRY UNIT PVC POLY VNYL CHLORIDE COL COLUMN CO.13 COMBINATION COI NPR COI1°GOFPIE66ALE a CONC cocft-TE aT alARRY TILE CORN CONNECTION) a1T G AWITY CONY CONTINUOUS cam CONTRACTOR CONST CON6TRJCTlow R CPT CAROM RIRAD RADIUS/ R WS) CR CHAR RAIL R4 RETURN AR CT CERAMIC TUNE) CANTER TOP lie RESILIENT BASE cm COUNTER RCP REMFORMD CONCRETE PIPE CW COLD INTER RCVG RECEMNG RELIEF RR>3ER / RACE D Farm RECEPTACLE REFL FSR=(ED) (IVE) D DRYER REiR REFRIGERATION IGGER4TION / REFRiGGERATOR DASS. DOW APPLIED SYNTHETIC STUCCO RIE G RESISTER DEMO DEMOLITION REEF REW-0RRCE(D)(INCW DEPT DEPARM£NT REGD REQUIRED DETA7TL DETAIL REB RESILIENT OF DRNCMG ROWAN REV ImAs CN DIAM DIAMETER RH RIGHTWAND DM DIMENSION RFR RIGHT HAND REVERSE DISP DISPENSER RO IV" OPENING DN DIVISION RM ROOM ON DOWN R D ROUND DR DOOR RT RESILIENT TILE DS DOWNSPOUT WD RATED DUG DRAWING me RAMW D& DGUBLe RUC RAN IWATER CONDUCTOR OW DISHUNN6IER E S SA EACH S 6A SOUTH SUPPLY AIR E EAST 801J+D ATTEWLIW DLiA10ET TION EFO DREiIOR INSULATION FINISH GYM C S coRE EJ EXPANSION JOINTSCALE/SOLD ° D SCHEDULE(D) EL ELEVATION ELEC ELECTRIC aEcr G=CN ELEV ELEVATOR Sm SERVICE Erin OF Sa IAIE REETIFOOT ENCL ENCLOSURE MGD $LONG GLASS DOOR EP ELASTOMERC PAINT aH SNCE HUNG Ea IRiJAL SHLV SHELVES EGUPIEGaPT EOILIPMENT aw SHEET EWC ELECTRIC WATER COOLER SM SIMILAR! EAN ELECTRIC WATER HEAIER SLNT SHO SEALANT SANITARY NAPKIN DISPENSER E)OH EXIM EXHAUST D OSED/EOS'ANSION am SANrrARTNAPKIN RECEPTACLE EXSTG Dda18G SON SMLAIR - OPPOSITE NAND OPEC SPECIFICATION Ext so &M AN SIR SHELF 1 ROD F SOT STAINLESS STEEL FA FILE ALARM OTC SOUND TRAB 4MON CLAN FB FABRCATION STD STANDARD FM FACE OF NWX STG SEATING FC TILE CAMISET STL STEEL FD FLOOR DRAM $TOR STORAGE ION FOUNDATION $TRUC $TRUCTRALASTMEnn FE IN EXTINGUMHEIR SURF SWAM I = TIRE EXTNGIa 4M CAMOET SUMP SUOPEIpED II' FMIGIFD FLOOR SW SWTCH FHG FIE HOSE CAWV No STACIED UUIBHER 1 DRYER FM FINISHED) 6YM SYMMETRICAL FIXT R " FIXIUE FLOOR T FLMTD FLOOR MOUNTED T iH1EAD(6) R.CUIR FLUORMCENT TMA TO BE ASSIGNED FO FINISHED CFO" TSL TABLE FOM PACE OF BLOp( TC TOP OF am we FACE OF STUD TIP TOP OF DRAM FP FRIEPROa7NG) SOWED SCHEXLM) FRM FRAME TmAr TELEPHONE FS FULL SIZE TEMP TEMP RATAE /TEMPER® FT FLETIFOOT TER TERRAW FM FOOTING T 4 G TONGUE 4 GIROOVE FUT I`UW 1H11( THRESH THICICHES$) THRESHOLD G Ti TOOLED JOINT GA GAGE/ mow TOJ TOP O: JOIST TOO TOP OF SEAS GAR CtARKtE TOP OF STEEL. ALV GALYANIZ GALVANIZED TOILET PAPER DISPENSER cis cis GRAB BAR TYP TYPICAL GG GENERAL CaNTRACTOR GL GLASS GRIN GRAN (WIOOD) U GRN0 GROUND U U4x RCUT RIT G GROUT IL aCeRURIIER'6 LABORATORY GO CAM SQUARE FOOTAGE RIRd WTSOHF.D GWC (sYSUM UNIZOARD UON UN.M aKRIVISE NOTED UTL UTILITY GYP GYPSUM H V VAR VARLETS) (D) THOSE AS VAPOR SARRREW VINYL W a HR HAR VCT VINYL COMPOSITION TILE He HANDICAP VFW VERTICAL HCR HOLLOW CORE VEST VEST VESTIBULE HDWAVA HARDWARE YIPVERIFY IN FEW D HOW HARDWOOD me VENEER INGTANRUT HEIGHT yr VINYLTILE HM HOLLOW METAL Vwc VINYL WALL COVERING HORZ HORIZONTAL HTG HEATN6 HVAC HEATHY, VENTILATING N W AR CONDITTANNG W WIDTH/ WEST / IIWSHER NW HOT WATER gy WITH WOOD 0.E I me WATER T D NODE DIAMETER/ NSDE DMI36CN at WATER COOLER W-40114CANIDESCENTWD WOOD/ WOOD VENEER NCL INCA JA rdD) (ING) WGT/ WT WEIGHT INFO INFORMATION WH WATER HEATER/ HYDRANT NMUL NMULATWN W WROUGHT IRON MT NTEROR WC WALK_N CLOSET Nv INVERT IIIA WINDOW I" IRON PPE 60 UP WALLPAPER UAID WALL BUMPER IUM WRE MESH J IWID Ion= JAN JANITOR UP WWTEW+ROOF JIB JUNCTION ISM we WRE wvm Jc JANrrOR CLOSET JOT JOIST JT MINT T Y TARO K KIT KITCHEN KO KNOCKOUT KPL KM PLATE LAM LAMINATE(D) LAY LAVATORY LB POND LLx LADEN LF LINE -Alt TOTTA V LGIL LONSSAmTH LN LEfT NOV LHR LF-T HAND FEVElft LL LIVE LOAD La LAGaER LT(w LIGHITIG LYL LAMINATED VEER LU M LWLTWR LIGHTWEIGHT BUILDING CODE SUMMARY -COMMERCIAL PROJECTS BUILDING DATA : OCCUPANCY: ❑ ASSEMEILY [Rr BUSINESS ❑ EDUCATIONAL ❑ MERCANTLEWINESS ❑ HAZARDOUS ❑ FACTORY -INDUSTRIAL ❑ INSTITUTONAL (UNRESTRAINED) ❑ DAY-CARE USE CONDITION MEDICAL EXAM ❑ INSTITUTIONAL (RESTRAINED) ❑ RESIDENTIAL ❑ STORAGE ❑ HEALTH CARES CHAPTER 12 - NSA LIFE SAFETY CODE MIXED OCCUPANCY: YES ❑ NO [r]' SEPARATION: IHR CONSTRUCTION TYPE : IA ❑ IB ❑ IIA❑ I IS ❑ IIIA❑ 1115 Iv ❑ vA ❑ ve ❑ MIXED CONSTRUCTION: YES ❑ No Q TYPE: TYPE II l 111) NFPA 220 ❑ SPRINKLED T YES Rr No ❑ wA ❑ n3 BR DD) : LIE SAFETY SYSTEM= EhERGsENCY LIGHTING and EXIT SIGNAGE SMOKE DETECTION SYSTEM PANIC HARDWARE YES [' NO ❑ WA ❑ YES ❑ NO 9 WA ❑ YES NO ❑ WA ❑ EXTT REfiUIFAI'M MAXIMUM TRAVEL DISTANCE TO EXIT - 300'-O" FROM ANY POINT OWF E FOOTAGIE CALCULAT0 6 SQUARE FOOTAGE WADER MP%%l3'IBNT 2302 80 FT NMSER EXITS : TOTAL SQLW FOOTAGE OF SPACE 2362 SF. DIYDED BY NET/m FT PER OCCUPANCY IdM _ 24 TOTAL NIMER OF PEOPLE ON FLOOR HUMMER OF DOORS PROvIDED 4 NUMBER OF DOORS REGIJIRED: 2 PERIMrrTWG Ataa Crs ZEPHYR HILLS BUILDING DEPARTMENT APPLICAME COM (CURTM EDMM ONLYA FLORIDA EXISTING BUILDING CODE OW) LIFE SAFETY CODE / NFPA 10 (2003) FLORRDA MECHANICAL CODE (2001) FLORIDA PLUMBING CODE (2001) FLORIDA BUILDING CODE - FUEL GAB CODE (200T) NATIONAL. ELECTRICAL CODE (2006) FLORIDA FIRE PREVENTION CODE (200T) FLORDA BUILDING CODE (2009) SUPPLEMENT DESIGNED IN ACCORDANCE WITH THE FLORIDA BUILDING CODE 2001, SECTION *09 FOR DESIGN PREOSURES. SYMBOLS: REVIEW DATE 3ILI- CITY OF ZEPHYRHILLS , PLANS EXAMINER - ALL WORK SHALL COMPLY WITH ALL PREVAILING CODES, FLORIDABUILDING CODE, NATIONAL ELECTRIC CODE AND CITY OF ZEPHYLS ORDINANCES RHIL CONSTRUCTION DOCUMENTS FOR: GREAT EXPRESSIONS DENTAL CENTER 7950 & 7944 GALL BLVD. ZEPHYRHILLS , FLORIDA ARSA Or- ll><JOR< SITE PLANr(a 1;3UBMITTED PLANS) NAVE BEEN I,EVIEWE* aY ZEPHYRHILL E S HALLS OFFICE Date: -•-- a0viewer: PROJECT LOCATION PROJECT RECORD ISSUE DATE: 02123A1 REVISION DATE REI IARKS PROJECT SUMMARY THIS PROJECT CONSISTS OF: -AN INTERIOR BUILD -OUT FOR A MEDICAL OFFICE -THE ADDITION OF WALLS, DOORS, AND HC RESTROOMS SHEET INDEX / A-1 COVER / SPECIFICATIONS / VICINITY MAP 1 LEI- LIFE SAFETY PLAN X6 J9 A-2 RENOVATION PLAN U'' A-3 DIMENSION PLAN q�0rf,V� A-4 REFLECTED CEILING PLAN C i 1j A-5 PARTITION TYPES, DOOR SCHEDULE, AND FINISH SCHEDULE 1 T I 04, A-6 HC RESTROOM DETAILS U A-1 INTERIOR ELEVATIONS A-13 CONSTRUCTION DETAILS E-I ELECTRICAL PLAN E-2 ELECTRICAL SPECIFICATIONS M-1 MECHANICAL PLAN M-2 MECHANICAL SPECIFICATIONS P-1 PLUMBING PLANS P-2 PLUMBING SPECIFICATIONS P-3 MEDICAL GAS PLANS P-4 PLUMBING DETAILS P-5 PLUMBING DETAILS 'saoueuiao }eoq Due SOPOO VddN algeoildde lie tW soueildwoo up aq oI aanl!eI sdopequoo 94I lol Al!l!g!suodsai ou sawnSM III!D SU -aouelldwoo w seaie asoyl 6uuq oI esuedxe egos jap le GA4!ligisuodm alos sdcgoejjuoa ayI aq lleys;! 'aoue!ldwoa-uou Io seeie sleanau uo edsui aps �o ua!Ieu!wexa �ayHnl Ie41 IUana ayI ul saaueu!pJo pool Due sapoa VdJN elgealldde lie 41!m eoucildwoo alaldwoo ui aie sueld ayI Ie4I amsue of,I!!!glsuodsal aloe s�olaejIuoa ayI s! II -sueld peU!wgns ayI Io Ienadde leug a aq oI papualul IOU sl Ma!naj slyl -sapoo Males ai!I apeo!idde yI!nn aaueydwoa u! iolaeiluoo ayI Is!sse oI nna!naJ tiosina e si peg!wgns sueld Io MGIA@J slyl pas!npe aq aseald TO THE BEST OF THE ARCHITECT OR ENGINEER'S KNOWLEDGE AND 11 BELIEF, THESE PLANS AND SPECIFICATIONS COMPLY WITH THE 2001 FLORIDA BUILDIWi CODE AND WITH ALL 20IN SUPPLEMENTS. THE DRAWINGS t DESIGN ARE VALID FOR 12 MONTHS FROM DATE OF BEING SEALED. TO THE BEST OF THE KNOWLEDGE OF THE ARCHITECTS OR ENGINEERS, SAID PLANS AND SPECIFICATIONS COMPLY WITH THE APPLICABLE MINIMUM BUILDING CODES AND THE APPLICABLE MINIMUM FIRE SAFETY STANDARDS. ALL DIMENSIONS AND JOB CONDITIONS SHALL BE VERIFIED BY THE CONTRACTOR, ANY AND ALL DISCREPANCIES SHALL BE REPORTED TO THE ARCHITECT PRIOR TO COMMENCEMENT OF CONSTRUCTION. ISSUE DATE REVIEW 02/22/11 PERMIT 02/23/11 Rr=V. REV. REV. REV. THESE DOCU•ENTS, DESIGNS, NOTES, DETAILS AND SPECIFICATIONS AND CONCEPTS ARE THE SOLE PROPERTY OF FROZE DESIGN, INC. AND SHALL NOT BE REPRODUCED, RE -USED OR COPIED FOR OTHER PROJECTS, IN U 40LE OR PART WITHOUT THE WRITTEN CONSENT OF FRANC FROZE, ARCHITECT, AIA, ALL RIGHTS ARE RESERVED SY THE ARCHITECT IN ACCORDANCE WITH Ub. COPYRIGHTT AND PATENT LAWS. UNAUTHORIZED REPRODUCTION WALL BE PROSECUTED TO THE FULL EXTENT OF THE LAWN O O N 0 n I� V 1 O WHQQ i-+ P4 4 O cn . W — � _y �-, U P4 W W ORA FRANKL IN FRAM, IV SWEET TITLE COVER SPI=CI CICWA TIONS VICINIt%' MAP UMBER SWEET NIA 1-11 '+ f dEANSOF EGR4SS 5 LIGHT / / / / / / LIFE SAFETY PLAN SCALE: 1/4" = 1'-0" 3 OF EXIT REQUIREMENTS: MAXIMUM TRAVEL DISTANCE TO EXIT - 300'-0" FROM ANY POINT, SQUARE FOOTA5E CALCULATIONS: SQUARE FOOTAGE UNDER IMPROVEMENT 2552 50 FT NUMBER EXIT5 : TOTAL SQUARE FOOTAGE OF 5PACE 2552 5.F. DIVIDED BY NET/50. FT PER OCGUPANGY 24 TOTAL NUMBER OF PEOPLE ON FLOOR. NUMBER OF DOOR5 PROVIDED 4 NUMBER OF DOORS REQUIRED: 2 * TO THE BEST OF THE ARCHITECT OR ENGINEER'S KNOWLEDGE AND BELIEF, THESE PLANS AND SPECIFICATIONS COMPLY WITH THE 20OT FLORIDA BUILDIN6 CODE AND WITH ALL 2001 SUPPLEMENTS. * THE DRAWINGS # DESIGN ARE VALID FOR 12 MONTHS FROM DATE OF BEING SEALED. TO THE BEST OF THE KNOWLEDGE OF THE ARCHITECTS OR EW-%INEERS, SAID PLANS AND SPECIFICATIONS COMPLY WITH THE APPLICABLE MINIMUM BUILDINGG CODES AND THE APPLICABLE MINIMUM FIRE SAFETY STANDARDS. ALL DIMENSIONS AND JOB CONDITIONS SHALL BE VERIFIED BY THE CONTRACTOR, ANY AND ALL DISCREPANCIES SHALL BE REPORTED TO THE ARCHITECT PRIOR TO COMMENCEMENT OF CONSTRUCTION. ISSUE DATE REvIEW 02/22AI PERMIT 02/23/11 REV. REV. REV REV. THE DOGIIMeM DES&A NOTES, DETAILS AND SPECIFIGAWM AV GOW2FM ARE THE 501.E PROPERLY OF FRAM DESIGN, INC. AND SHALL NOT BE REPRODUCED, RED oR GoPw FOR am PROJWI% IN WHOLE OR PART WIT = 7W MTrEN WSW OF FRANK FRAM, ARCHITECT, AUK ALL RaffS IRE IRMERVED BY THE ARCHITECT IN ACCORDANCE WITH UA GOPMSW AND PATENT LAMS. UNAUTNORIzEp REPRODUCTION WILL BE PR09EC W TO 1M FULL EXTW OF nE LAW. O O N O r-i SHEET TITLE LIFE "PINTY MAN FIRE PREVENTION GENERAL NOTES: ISWE DATE REVIEW 02122AI CODES: MRMIT 02/23AI L STENCIL ALL FIRE RATED WALLS A50YE CEILING WITH RED PAINT IE: "SMOKE BARRIER ONE HOUR RATING REV. L ALL CONSTRUCTION MUST MEET THE REQUIRk11ENTS OF NFPA PROTECT ALL OPENINGS" PER 55C 1041.19 STENCIL TO 241, 2004 EDITION FOR STANDARD OF SATING BE ON GW5 OR CMU - WHICHEVER PROVIDES FIRE REV. CONSTRUCTION, ALTERATION, AND DEMOLITION OPERATIONS. RATING. IREV. 1. ALL CONSTRICTION MUST MEET THE CONDITIONS OF NFPA-101 2006 EDITION CHAPTER 10, INTERIOR FINISH CLASSIFICATION REV. ,.� LIMITATIONS. 2. DIMENSIONING IS TAKEN t0 THE FADE OF BLOCK OR `'� 3. MUST MEET THE REQUIREMENTS OF NFPA-10 2002 EDITION, WOOD STUD. STUDS 3 J" (NOM. 411) BLOCK 1 1" (NOM. v ). 1 STANDARD FOR PORTA5LE FIRE EXTINGUISHERS. " 4. ALL FIRE EXTINGUISHERS MUST BE CERTIFIED BY FIRE 3. EXTERIOR WALLS HAVE I ° METAL STUD. J" OFF FACE ff`W1 , D COW NUM, MAILS WI AND �# SPEGIP�ATIOW9 AND CONCEPTS ARE THE WILE EXTINGUISHER COMPANY. OF INTERIOR 5LOCK WALLS FURRING. FWFERTY OF ADM OR COPIM FOR BE FROMM, IN WHOLE OR PART HTHOUr THE W"M ;< 4. COORDINATE ALL DIMENSIONS AND ELEVATIONS WITH COWA T OP PRANK MAZE, ARCHITECT Ma LAYING; OUT PHYSICA L STRUCTURAL DRAWINGS BEFORE LA BUILDING IN F CONTACT ARCHITECT WITH ANY ALL RIGHTS ARE RESERNID BY THE ARCHITECT M BUILD ELD. ARCH TE .. ,. v................................. ........................................................................................... .......................... .................... .. ............:................,.:.......... ..................... :�:s-^�.r.....................:...... AuoRDM,IGE wrtH ua coPrR€e�FfT Mm PATENr LMis. ': '..... .................. DISCREPANCIES OR QUESTIONS AS TO CRITICAL uw�un aRlzEv R£PROMTION NULL EE PROSECUTED TO ... .......... ; ; ... ... ..................... . DIMENSIONS THE PULL EXTENT oP T}'E LANL l H16H WALL I - IFE Yr 4< OCIA 1 cv O - 1 RENOVATION NOTES: ITS PRIVATE ICE L6. HT. I L6. HT. Q + 4'-0" G HT. }1 L ALL WORK TO BE DONE IN ACCORDANCE WITH THE LATEST 44*4 r' STANDARD BUILDING CODE AND ALL LOCAL BUILDING trl CODES. cn 2. ALL DEMOLITION WORK SHALL BE PERFORMED WITH "DUE 121 BREAK ROOM CARE AND DILK,ENCE SO AS t0 PREVENT 11aE ARBITRARY x + q -0 GL6. H . WHICH ARE INTENDED To REMAIN IN USE AND THE ROUTING OF O DESTRUCTION OF INTERRUPTION OF CONCEALED UTILITIES - - - - - WHICH COULD NOT BE PRE -DETERMINED UNTIL DEMOLITION O - - - - - - - - - - - WAS STARTED. ALL SUCH DISCOVERIES OF UTILITIES DURING ON DIFFERENT FROM THE DEMOLITION �INDICATED, ESS LL441CH ACHANGE DIRECTION, ETC, TO THE 115 MECHANICAL ROOM -OM ARCHITECT / OWNER BEFORE REMOVAL �FOR FINAL HO + a'-0" GL6. HT. 1 n + a'-o' DISPOSITION H---1 �--1 115 116 3. REMOVE ALL CONSTRUCTION DESIGNATED t0 BE REMOVED j AND CLEAR TO RECIEVE NEW WORK AS HERE -IN INDICATED. O (� "�O I I 1 PI NETVdORiC xl 4. REMOVE PORTIONS OF EXISTING CONSTRUCTION AS DRAWN w p,..i O �/ ro 1°I " AND PATCH TO MATCH ADJACENT CONSTRICTION TO ACHIEVE � � PI i i O i + q -0 T,... UNIFORM, NEW APPEARANCE. I I i 5. THE OWNER WILL NOT BE HELD LIABLE FOR FIELD CHANGES I I THAT ARISE FROM CONTRACTOR ERROR OR OMISSION OF w 113 LAB I MATERIALS. O w + a'-O' L6. }{ P1 PI + dI-0 GL6. HT. i 6. THE CONTRACTOR GUARANTEES ALL WORK AGAINST FAULTY Q OR IMPERFECT MATERIALS OR WORKMANSHIP ALL WORK Fill O o EXISTING ONE HP, RATED SHALL BE ENTIRELT WATERTIGHT AND LEA(PROOF. ALL - - - - - J M #6 DEMISING WALL TO REMAIN MATERIALS ARE INSTALLED IN ACCORDANCE WITH 1 + MANUFACTURER'S RECOMMENDATIONS. . I I 1. THE CONTRACTOR SHALL GIVE WRITTEN NOTICE TO THElu I I ARCHITECT OF ANY MATERIALS, EQUIPMENT OR DESIGN - - - - --TIC - - - - FEATURES WHICH HE BELIEVES INADEQUATE OR UNSUITA5LEt �+ � ) �T�� EXISTING Q I I L�J I I _ EXISTING IN VIOLATION OF LAWS, ORDINANCES, OR RULES AND w RESTAURANT t°s I I I I RESTAURANT REGULATIONS OF ALL AUTHORITIES HAVING JURISDICTION U N OVER THE W1OIWA AND OF ANY NECESSARY ITEMS OR WORK I I I I I I OMITTED FROM THE DRAWINGS OR SPECIFICATIONS. I I STERILIZATION I I S PLANS WERE DEVELOPED FROM INFORMATION SUPPLIED 16H WALL I I I10 + q'-0" GL6. HT. I I I I BT THE OWNER AND EXISTING CONDITIONS OBSERVED. ANY I I I DISCREPANCIES BETWEEN DRAWINGS AND EXISTNG lOq + a' -a GL6 *I CONDITIONS ARE TO BE REPORTED TO ARCHITECT PRIOR TO EX15TINS ONE HR RATED 7' HIGH WALL S� WORK NA S� ITEM AND BEFORE INCURRING DEM151N6 WALL TO REMAIN � � II „ � 9. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS° I I INDICATED. FABRICATION SHALL BE BASED ON THE ACTUAL FIELD DIMENSIONS ONLY. II I I PI trl 10. ARCHITECT HAS NOT ANY INVESTIGATION AS I I I I I I to THE PRESENCE OF ASBESTOS OR ANY OTHER HAZARDOUS I I I I Pl I I SUBSTANCE AND ASSUMES NO RESPONSIBILITY WITH RESPECT I I I I i" To SAME. I I i i 101 CLOSET IL DESIGN DRAWING INDICATE SCHEMATIC STRUCTURAL pRq FRANKLIN Y I I + a'-0" G HT. I I MEMBER LAYOUT. CONTRACTOR SHALL SUBMIT SHOP PAN-G DRAWINGS INDICATING ACTUAL LAYOUT OF ALL STUCTURAL TO INSTALLATION, ALONG - - - �- I MEMBERS FOR APPROVAL PRIOR AL.LA , AL EXAM =:>.r, WITH IS S 'S CALCULATIONS. REGISTERED ENGINEER CAL I }�I REG Tta1CTIJRAI ILn q -0 G . HT. INSt INYs TO ALL MEMBERS SHALL BE ALLED ACCORD 0 II o RECOMMENDATIONS I BRACING, MANUFACTURERS OWS INGL NG BRAC ACTURERS RECOMMEND UD c*U o � � PI E M 8 `<: I I SPACING, ETC. I I 11. CONTRACTOR PRIOR TO INSTALLATION SHALL FIELD > _ # oc I I I DISPLAY VERIFY ALL EXISTING CONDITIONS AND BRING TO THE A N I I ATTENTION OF THE ARCHITECT ANY DISCREPANCIES. U a �• .-- w.. �, � I I 13. CONTRACTOR IS REQUESTED TO VISIT THE SITE, COMPARE a 0 <e> 1 l pl THE DRAWING AND SPECIFICATIONS WITH VISIBLE EXISTING A }fALLWAY OQ CONDITIONS DISCREPANCIES PRIOR To WOW ARCHITECT SI�MISSION SO AN � w {-I(, 104 I SITE WILL IN + q'-0" GL6. HT. _..: ADDENDUM CAN BE ISSUED FAILURE TO VISIT TE U] 1 103 + a'-0" GL6. w NO WAY RELIEVE THE CONTRACTOR FROM NECESSITY OF 04 I I PI - FURNISHING ANY MATERIALS OR PEIWORMING ANY WORK THAT MAY BE REQUIRED TO COMPLETE WORK IN ACCORDANCE WITH DRAWING AND SPECIFICATIONS WITHOUT ADDITIONAL - - - - - - - -_-__--_-_-_-_-__- COSTS TO THE OWNER I I 14. THE CONTRACTOR SHALL- BE RESPONSIBLE FOR THE I I EQUIPMENT AND METHODS USED IN THE ERECTION OF HIS \ €................. � WORK COVEi�D BY THE CONTRACT, BUT THE ARCHITECT Q q RESERVES THE RIGHT TO APPROVE SUCH EQUIPMENT AND - O 15 THE CONTRACTOR SHALL BE TOTALLY RESPONSIBLE FOR Q 1 °'' ,.x •• � I >, DEVIATIONS FROM THE CONSTRUCTION � m 1 PI I WAITING TOQM--- --- „3 INSTALLED WITHOUT APPROVAL OF ARCHITECT I 101 ADMINISTRATION _, I 100 AND LOCAL JURISDICTION. THIS INCLUDES REPAIR COSTS 1 + 9 -0 GL6. HT. x N + q'-O" GL6. HT. _._. NECESSARY To CORRECT UNAPPROVED WORK INSTALLED. N` BUSINESS OFFICE ��� I to � + q -0 GL6. HT. _„....,...... , RENOVATION LEGEND: NO ON I � _ ' I w .----- ...------ .__.___........._..__._w. � L..........._ ............_ .... __ > . _......_.......... ._._............ • INDICATES NEW WALL .x : .:......... : f� w ,aa INDICATES EXI5TI1N16 WALL - 00 - E O ACCESS BOX FOR FIRE DEPARTMENTr ~ ? ,� ; CA 41 ....w.�_...�...�...__._. _..._. _._... .. ........ � __ _. TO THE BEST OF THE ARCHITECT OR EN61NEERS KNOWLEDGE AND U BELIEF, THE5E PLAN5 AND 5PECIFICATION5 COMPLY WITH THE 200T x FLORIDA BUILDING CODE AND WITH ALL 20051 WPPLEMENTS. w ' THE DRAWINGS d DE516N ARE VALID FOR 12 MONTHS FROM DATE SHEET TITLE OF BEING 5EALED. 9ZENOVATION PLAN TO THE 5EST OF THE KNOWLEDGE OF THE ARCHITECTS OR ENGINEER'S, SAID PLANS AND SPECIFICATIONS COMPLY WITH THE APPLICA5LE MINIMUM BUILDING CODES AND THE APPLICA5LE MINIMUM Fin SAFETY STANDARDS. SHEET NUMBER RENOVATION PLAN ALL DIMENSIONS AND JOB CONDITIONS SHALL 5E VERIFIED 5Y THE 5GALE: 1/4" = 1'-0" CONTRACTOR, ANY AND ALL DISCREPANCIES SHALL 5E REPORTED TO THE ARCHITECT PRIOR TO COMMENCEMENT OF CONSTRJCTION. DIMENSION PLAN 50ALE: 1/4" = 1'-0" -4 -�vr * TO THE BEST OF THE ARCHITECT OR ENGINEER'S KNONLEXE AND BELIEF, THE5E PLAN5 AND 51FECIFICATION5 COMPLY WITH TI-E 2007 FLORIDA BUILDING CODE AND WITH ALL 200a SUPPLEMENTS. * THE DRANINC75 d M516N ARE VALID FOR 12 MONTH5 FROM DATE OF BEING SEALED. TO THE BEST OF THE KNOWLEDGE OF THE ARCHITECTS OR ENGINEERS, SAID PLANS AND SPECIFICATIONS COMPLY WITH THE APPLICABLE MINIMUM BUILDING CODES AND THE APPLICABLE MINIMUM FIRE SAFETY STANDARDS. ALL DIMENSIONS AND JOB CONDITIONS SHALL BE VERIFIED BY THE CONTRACTOR, ANY AND ALL DISCREPANCIES SHALL BE REPORTED TO THE ARCHITECT PRIOR TO COMMENCEMENT OF CONSTRUCTION. ISWE DATE FREVIEW 02/22/11 PERMIT 02/23/11 REV. wv. Irv. wv. THIME D0C1Ih W% DESIGNS, NOTE, DETAILS AND SPEGIFIGATM AND CONCEPTS ARE THE 501E PROPERTY OF FRAM DE516N, INC. AND SHALL NOT BE REPRODUCED, Petty OR COPIED FOR OTHER MAWS, IN *10LE OR PART PATHOUT THE WR"M 60NOM OF FRANK FRQZ APZHTEGT, NA ALL RI6NT5 ARE RESERVED BY THE ARCHTTEGT IN ACCAR WE WITH U5. COPYRIGHT AND FATBR LAWS. UNAUTNORIZED 109WUCTION WILL BE PROSECUTED TO THE FULL Ex W OF THE LAK O O N O Q w O pq (u U SHEET TITLE 01MONSION Pl.AN m r5 REFLECTED CEILING PLAN SCALE: 1/4" = 1'-0" ELEC.7R I GALL LEC FEND 220V RECEPTACLE 250 V DRYER RECEPT F -._.....-. ........ _-- _ _-..__... _ ---- _.._.._..___---.... __._ _ CEILING FAN ONLY 9 DUPLEX ABOVE GNTR. REGEPT. 1ML T REGEPT. rn SAITCHEP `�4" A.F.F. DUEL 1� DUPLEX (SPLIT WIRE) REGEPT. CEILING FAN W/ I LIGHT FIXTURE q?GM® G RGUIT INR r�'�01 G RGUIT IN S PALE a 'CH SW © TELEV15ION GABLE JACK $a H - So DI ME ' � HONE OUTLET 54-KA TI LINE sQ SMOKE DETECTOR -4 ' WATER PROOF CEILING MOUNT I 2 TELEPHONE OUTLET LINE 2) ......... ......... - 6HESSED ======(FLUOTRE5CENT I Pe I ---- - --- --- DOOR SELL DOOR CHIME LI&HT FIXTURE CEILIN& MOUNT RECESSED HALOGEN SPOT LI&HT FIXTURE i 1c INTERCOM STATION FO LI &HT FIXTURE ® SMOKE DETECTOR/ WALL MOUNT AB CARBON MONOXIDE DETECTOR -� TRACK LIGHTING ® FOR APPL ANCE11 $O�YY Y VQ EXHAUST FAN 0 JUNCTION SOX El' EQUIPMENT DISCONNECT EXHAUST FAN LIGHT COMBO DOUBLE FLooDLI&HT ®� �OORAM j LTG/PWR BRANCH PANEL .�� I. PROVIDE AND INSTALL LOCALLY CERTIFIED SMOKE DETECTORS AND CARBON MONOXIDE DETECTORS AS REND IRED INNC7 IRE° Q IREMMENTT5°OFF ATILLL iSOV0ERNIIN6°CODES. 2. PROVIDE AND INSTALL &ROUND FAULT CI (NEC,)RQUIT-INTERUPTERS �&FI) AS RRQUIR MONTS OF °ALLLL60V/ERNII CODE AND MEETING tiE 5. UNLESS OTHERWISE INDICATED, INSTALL SWITCHES d RECEPTACLES AT 5i�f€LFOLOWIIN��HEI6F+T5 ABOVE FINISH FLOOR: _W 1ELEPHOctt�SNE.... l 4 .'�TEL EVISION.....14" 4. &ROUND FLOOR ELECTRICAL EQUIPMENT TO BE MOUNTED AT REQUIRED HEI&HT FLOOD LEVEL. CONTRACTOR TO VERIFY EXACT HEI T S. PROVIDE AND NA O ARZ U(NEG) AND �TIN6 TINE REOUIREMENTS OF ALL 60VERNIN6 GORES. 6. ALL PLUMBING ELECTRICAL AND MECHANICAL ROU&H-IN5 MUST BE COMPLETE Fqr IN5PEGO D, AND APPROI/Eij BEFORE REQUE5TIN& THE FRAMING INSPECTION. : TO THE BEST OF THE ARCHITECT OR ENGINEER'S KNOWLEDGE AND BELIEF, THESE PLANS AND 5PECIFICATION5 COMPLY WITH THE 2007 FLORIDA BUILDIN6 CODE AND WITH ALL 200a SUPPLEMENTS. * THE O WINC75 d DE515N ARE VALID FOR 12 MONTHS FROM DATE OF BEING SEALED. TO THE BEST OF THE KNOWLEDGE OF THE ARCHITECTS OR ENGINEERS, SAID PLANS AND SPECIFICATIONS COMPLY WITH THE APPLICABLE MINIMUM BUILDING CODES AND THE APPLICABLE MINIMUM FIRE SAFETY STANDARDS. ALL DIMENSIONS AND JOB CONDITIONS SHALL BE VERIFIED BY THE CONTRACTOR, ANY AND ALL DISCREPANCIES SHALL BE REPORTED TO THE ARCHITECT PRIOR TO COMMENCEMENT OF CONSTRUCTION. ISSUE DATE REVIEW 02122AI PERMIT 02/23/II REV. mv. REV REV. THE DoCUr8 m, DESIGNS NOTES, DETAILS AND SPE MATM AND CONCEP1r ARE TW 801.E PROPERTY OF MATE DE W MC. NO %bkL NOf EE REPRODUCED, RED= OR COPIED FOR onot PRaZZ7 , M WHOLE OR PART NAliM TW NRPI M CONSENT OF FRANK FRAM ARCAMT, MA. ALL ROM ARE RESERVED BY M ARCHITECT IN ACCORDANCE WITH Us. COPYRIGHT AND PATENT LANE. LWHORM REPRODUCTION WILL BE PROSEf M TO THE FUl PXTE11' aF THE LAYS O 0 N O Q v 1 O O � !� U U V��N ORA FRANKLIN SHEET TITLE RVLecTRa COMING PLAN ..I � _ I ���u�u�ir�n� � �, wu u�ruuuw�. �u �u.�,rEiwuuuW:�wuw�wruuwr�r■�■■�u�r+r�ururwuuuuar�moru�w uuruia���iG.r �� � �yauu b I :: , � � l,: ,J��: �fyrl,. �� _ �I . ;�>����1�I1�d�lYIIIV�iVVJl1>�W�.t1 �,— .<: - � _ _ _ �, �. �� � �I1��L„u���.11 ..,��II�� �.. � � ,� �. � �E rl ��I����,r��,..u�.�o�11��:�iiJdL�►>�.L�I�II��;Yi��.�.� �:, ,� ,; �.:.. I a �,a�uuu�Wa� . �w�r��a O INTERIOR BIFOLO PAIR DOOR 50HEDULE MARK LOCATION DOOR FRAME REMARKSSIRE TYPE MAT FIN MAT FM 103 WC RESTROOM 3'-0" x 1'-0" x 13/4" A WOOD PNT WOOD ENT. LOCK AND CLOSER 104 HALLWAY 3'-0" x l'-0" x 13/4" A WOOD PNT. WOOD PNT. 101 CLOSET (PR) 2'-b" x l'-0" x 13/4" B WOOD PNT. WOOD PNT. DBL. BIFOLD 115 MECHANICAL ROOM Y-O" x l 0" x 13/4" A WOOD PNT. WOOD PNT. LOUVER ON DOOR FOR VENTALATION 116 NETWORK CLOSET (PR) I -bI1x l -0 x 13/4I' B WOOD PNT WOOD ENT. DBL BIFOLD in HC RESTROOM V-0" x l'-0" x 13/4" A WOOD PNT. WOOD PNT. LOCK AND CLOSER lie PRIVATE OFFICE V-0" x l'-0" x 13/4" A WOOD PNT. WOOD PNT. LOCK 121 BREAK ROOM V-0" x l'-0" x 13/4" A WOOD ENT. WOOD PNT. [122 STORAGE V-0" x l'-O" x 13/4" A WOOD PNT. WOOD PNT. DOOR SCHEDULE AND TYPES SCALE: 1/4" = 1'-0" BRACE TO STRUCTURE ABOVE + 9'-0"-10'-0" (VARIES)11 . `"`� + 9'-0"-l0'-0" (VARIES) BOTTOM OF ACT BOTTOM OF ACT 3 1" METAL STUDS ' AT 24" O.G. TYP. TO I� a I LAYER ? GYPSUM WALL DECK , I ::... 1 LAYER IGYPSUM WALL EACH SIDE OF 3 1" METAL I;...,,, - EACH SIDE OF 3 1" METAL STUDS : I:Ama:. _A STUDS SOUND ATTENUATION BLANKET BRACE TO STRUCTURE ABOVE + S'-0"-10'-O" (VARIES) + 9'-0"-10'-0" (VARIES) BOTTOM OF ACT _ BOTTOM OF ACT 3 1" METAL STUDS AT 24" O.C. TYR TO DECK I LAYER I" GYPSUM WALL EACH SIDE OF 3 P" METAL STUDS CONTINUOUS 25 GAUGE CONTINUOUS 25 GAUGE n CONTINUOUS 25 GAUGE METAL STUD TRACK METAL STUD TRACK METAL STUD TRACK Dla ANCHORED WITH Dla I aANCHORDWITH ANG WITH D POWDER ACTUATED TYPE POWDER ACTUATED TYPE POWDER ACTUATED TYPE FASTENERS AT 2'-0" O:C. _;.: FASTENERS AT 2'-0" OZ. FASTENERS AT 2'-0" O.C. .y MAX TRACK TO BE SAME '. (: a ' `: F MAX. TRACK TO BE SAME MAX TRACK TO BE SAME GAUGE AS STUDS I>> ;: ; ;. f GAUGE AS STUDS R. i— GAUGE AS STUDS BASE HI AP-10 BASE BASE H! '.",4E::1k BASE QFINISH SCHEDULE SCALE: * TO THE BEST OF THE ARCHITECT OR ENGINEER'S KNOWLEDGE AND BELIEF, THESE PLANS AND SPECIFICATIONS COMPLY WITH THE 2001 BASE 41 BASE FLORIDA BUILDING CODE AND WITH ALL 2005 SUPPLEMENTS. THE DRAWINGS t DESIGN ARE VALID FOR 12 MONTHS FROM DATE OF BEING SEALED. f � NOT RATED: SOUND BATTS ONLY F3 NOT RATED: SOUND BATTS ONLY f 1 NOT RATED BATHROOM WALLS BATHROOM WALLS. TO THE BEST OF THE KNOWLEDGE OF THE ARCHITECTS OR ENGINEERS, SAID PLANS AND SPECIFICATIONS COMPLY WITH THE APPLICABLE MINIMUM BUILDING CODES AND THE APPLICABLE F4 SAME A5 WALL TYPE PXGI:Pf b° F2 SAME WALL TYPE "PI" MINIMUM FIRE SAFETY STANDARDS. )�?��RATED PARTITION TYPES ALL DIMENSIONS AND JOB CONDITIONS SHALL BE VERIFIED BY THE CONTRACTOR, ANY AND ALL DISCREPANCIES SHALL BE REPORTED /2" = 1'-0" TO THE ARCHITECT PRIOR TO COMMENCEMENT OF CONSTRUCTION. ISSUE DATE REVIEW 02122AI PERT" IIT 02/23/11 REV. REV. REV. REV. TEESE DOQI'ENM, DESh", WoM, DETAILS AND SPECIFICATIONS *V CONCEPTS Aim THE BOLE PROPERTY OF FRAZE DEW INC. AND GHALL NOT 8E REPRODUCED, RE -USED OR COPIER FOR OTHER PROJECTS, IN MOLE OR PARE M OUT THE BM IEN CaMW OF FRANK FRAl'E, ARCHITECT, AA ALL RIGHTS ARE RESERVED FSY THE ARCHTIECT IN ACGOMANCE WrM U& COPYRIGHT AND PATENT LAW UNAUTHORIZED REPRODUCTION WILL DE PROSECUTED TO THE FULL EX w OF RE LAB( 0 0 0 Q v 1 0 V1 W�QQ O CIO U W o? o� ORA PRANICUIN PRAZE, IV SHEET TITLE PARTITION TYPES, DOOR SCHEDULE, 4 FINISH SCHEDULE SHEET NUMBER v w L 1 30" min. ..... .............. ........ 2/A-6 I 3/A-6 4/A-6 2 �£ is" mfn.. -., 36" min. 6" max v 1 TYPICAL nRESTROOM SGALE: I/2" = " 1 + 3011 min. Lo 2/A-6 3/A-6 " min 19411 3611 min 6" max TYPICAL �.�RESTROM 5 SCAL P-� QELEVATION A SCALE: 1/2" = 1'-011 6 ELEVATION A SGALE: 1/Z" = 1'-0" 1'-211 NOTE: PROVIDE INSULATION AT HOT WATER SERVICE B LINES AND DRAIN PIPE. (a,ELEn�l?� ALE 61-511 O_ELE���I?� B SGALE 9 b'-011 H6T. I'-311 NOTE: PROVIDE INSULATION AT NOT WATER SERVICE LINES AND DRAIN PIPE. 4 ELEVC SGALE: ��I?� H6T. C k E T � E NOTE: PROVIDE INSULATION AT HOT WATER SERVICE LINES AND DRAIN PIPE. ELEVATION C g SCALE: 1/2" = i'_011 S-6" 17"-19" 1 1/2" DIAM. A W/SAFETY 56" max. C=::= p" p" O ° O GRIP U TOI ET x o 0 r0 �TIS UE �_ E of I I I I I I I I0 LoO o n M M M po INSULATE N (V I-) r- r+j � I I I I CV HOT WATER I N AND DRAIN PIPES WASTE PAPER TOWEL FEMININE TISSUE SOAP TOWEL MIRROR & WATER TELEPHONE LIGHT FIRE DUPLEX URINAL TOILET WITH GRAB BAR THERMOSTAT RECEPTACLE DISPENSER NAPKIN DISPENSER DISPENSER BAR LAVATORY COOLER & SHELF SWITCH ALARM OUTLET GENERAL HANDICAPPED MOUNTING HEIGHTS FOR WALL ACCESSORIES SCALE: N.T.S. aMIRROR 1—B I SOAP DISPENSER TOILET T15%E 015PEN5ER FD CRAB BAR 36"x I Xt' DIA. MIN. E SW BAR 42"x I Yz' DIA. MIN. E TOILET PAPER DISPENSER lfl BACKIN6 KEYED NOTES: O5'-O" DIAMETER CLEAR ADA FLOOR AREA O50" x 46" CLEAR ADA FLOOR AREA O56" x b0' CLEAR ADA FLOOR AREA * TO THE BEST OF THE ARCHITECT OR ENGINEER'S KNOWLEDGE AND BELIEF, THESE PLANS AND SPECIFICATIONS COMPLY WITH THE 2001 FLORIDA BUILDING CODE AND WITH ALL 200E SUPPLEMENTS. * THE DRAWINGS 4 DESIGN ATE VALID FOR 12 MONTHS FROM DATE OF BEING SEALED. TO THE BEST OF THE KNOWLEDGE OF THE ARCHITECTS OR ENGINEERS, SAID PLANS AND SPECIFICATIONS COMPLY WITH THE APPLICABLE MINIMUM BUILDING CODES AND THE APPLICABLE MINIMUM FIRE SAFETY STANDARDS. ALL DIMENSIONS AND JOB CONDITIONS SHALL 5E VERIFIED BY THE CONTRACTOR, ANY AND ALL DISCREPANCIES SHALL 13E REPORTED TO THE ARCHITECT PRIOR TO COMMENCEMENT OF CONSTRUCTION. I;SWE DATE iREVIEW 02122AI PERMIT 02/23/11 REV. REV. REV. REV. THESE DoCIJ'IEM M "M6, NOiEB, DETAILS AND 611MCIPICA1101% *0 CONCEPTS ARE THE SOLE PROPERTY OP M42 DEW INC. AND SHALL W OE REPRODUCED, RE-MM OR COPIED FOR OTHER PROUECi9, M U40 E OR PART WITHOUT M UWtI N CONSENT OP FRANC FRAr- ARCFNTECT," ALL RIGHTS ARE DESERVED 8Y 11-E AWZWM Ci IN ACCORDANCE WRH Ul COPYRIGHT AND PATENT LAMS. UNAUiHORM RWPRODUCTiON WILL BE PR08ECM TO THE FULL EXiw of THE LAiLL SHEET TITLE He RESTROO" i =2ETAILS 4 ELEVA IONS SHEET NIUMBE A, 6 M 0 NE m STERILIZATION ROOM 3 SCALE: 1/2" = I'-0" CEILING LINE ADMINISTRATION DESK SCALE: 1/2" = I'-0" UL 1� n n NOTE : WHEN NEW CONSTRICTION, PROVIDE BLOCKING USING FIFE -RATED MATERIALS. STANDARD METHODS FOR FASTENING SHALL BE APPLIED. I 1 1 m 1 N N 1 \ � ( D BUSINESS OFFICE 1 CEILING LINE Q TYPICAL EXAM ROOM SCALE: I m N R 0 rim m &5�B LE: 1/2" = 1'-0" DBREAK �TMCALE: 1/2" I I I * TO THE BEST OF THE ARCHITECT OR ENGINEER'S KNOWLEDGE AND BELIEF, THESE PLANS AND SPECIFICATIONS COMPLY WITH THE 2001 FLORIDA BUILDING CODE AND WITH ALL 2M SUPPLEMENTS. * THE DRAWINGS E DESIGN ARE VALID FOR 12 MONTHS FROM DATE OF BEMG SEALED. TO THE BEST OF THE KNOWLEDGE OF THE ARCHITECTS OR ENGINEERS, SAID PLANS AND SPECIFICATIONS COMPLY WITH THE APPLICABLE MINIMUM BUILDING CODES AND THE APPLICABLE MINIMUM FIRE SAFETY STANDARDS. ALL DIMENSIONS AND JOB CONDITIONS SHALL BE VERIFIED BY THE CONTRACTOR, ANT AND ALL DISCREPANCIES SHALL BE REPORTED TO THE ARCHITECT PRIOR TO COMMENCEMENT OF CONSTRUCTION. 0 0 N O �k Q 0 �w w�QQ o U w � Lon 14 O O � w U `J��N SHEET TITLE INTERIOR ELEVATIONO Big BOX POSITION FOR NECTING CABLE RAIN CONTROLLER 8& ROLLER UNTIED SINGLE -GANG BOX. T'ERS 3/4' PLYWOOD ELEC. CIRCUIT220V SEE' 211 go ANCHOR VERTICAL 4x4 POSTS ON BOTH SIDES OF CABINET TO ROOF STRUCTURE ABOVE. USE METAL SUPPORTS TO ANCHOR POSTS ABOVE CEILING IF PLENUM SPACE IS DESIGNATED AS NON-CUMBUSTABLE. *X-RAY UNIT REQUIRES 120V PO W ER ON A DEDICATED I SA CIRCUIT. DRILL 314" 0 HOLE THROUGH STUDS & CABINET TO FEED POWER TO X-RAY UNIT. DRILL 3/4' 0 HOLE THROUGH STUDS CABINET TO FEED INTERCONNECTING CABLEFROM X-RAY UNIT TO MASTER c �v CONTROL (SPEC. 9A, IF MOUNTED N REMOTELY) OR EXPOSURE BUTTON (SPEC. 98). HEIGHT IS DETERMINED TO ALLOW f 110V POWER: FOR CONVERTER/ ���� FOR CABINET BELOW PASS-THRU_ PLATE COMPUTER �i i VERIFY THAT THE PASS THRU WILL CLEAR ALL CABINET FIXTURES (BAGKSPLASH, FAUCET, ETC,) WITH IT REQUIRES 120V x HENRY SCHEIN REP PRIOR TO A DEIICATE 15A / ; f DATA/ REMOTE CONTROL CHASE? CONSTRUCTION. _.. I14r_.. GYP. BIRD. SIDES SEE MANUFACTURER'S INSTALLATION TEMPLATE FOR MORE DETAIL. INSTALLER MUST VERIFY THAT WALL AND MOUNTING HARDWARE MEETS THE REQUIREMENTS FOR A 100 LIB, SHEAR LOAD, 450 LB. WITHDRAWAL FORCE AT EACH MOUNTING POINT AND 850 FT. I.B. LOAD MOMENT AS OUTLINED.IN THE MANUFACTURER'S INSTALLATION MANUAL SCALE; 31W' = V-9' NOT TO SCALE GYP, BRD. BOTH SIDES SEE MANUFACTURER'S INSTALLATION TEMPLATE FOR SPECIFIC MOUNTING AND ELECTRICAL REQUIREMENTS.. SCALE: 314' = 1'-U* �"Ell iiii, �► s: Fill I i 1! i SCALE 3/4,' = V-9' SECTION VIEW THE WALL AND MOUNTING HARDWARE MUST BE SUFFICIENT TO WITHSTAND A 100 POUND SHEAR LOAD AND A 450 POUND WITHDRAWAL FORCE AT EACH OF THE FOUR LAG SCREWS, 4x4VERTICAL POSTS ON EITHER SIDE OF PASS THRU CABINET, 2x4 FRAMING FOR REMAINDER OF WALL (STEEL OR WOOD DEPENDING ON CODE). S/B" GYP. BRIE. BOTH SIDES OF WALL MOUNTING SIDE OF CABINET LEFT SIDE VIEW ..... ......... --------- PLAN VIEW ■ !+ Mum= AIL SCALE: 3/W' = 1'-9' 2x4 .. ATTACHED TO STRUCTURE ABOVE 2'X 2' LAY -IN ACOUSTICAL TILE -TYP. HANGER WIRE -ATTACHED TO STRUCTURE ABOVE' WALL ANGLE RECESSED CAN LIGHTING WOOD TRIM RECEPTION COUNTER S/&' GYPSUM WALL. BOARD 2x4 BOTTOM PLATE BASE MOLDING TO BE DETERMINED * TO THE BEST OF THE ARCHITECT OR ENGINEER'S KNOWLEDGE AND BELIEF, THESE PLANS AND SPECIFICATIONS COMPLY WITH THE 2001 FLORIDA BUILDING CODE AND WITH ALL 20M SUPPLEMENTS. * THE DRAWING t DESIGN ARE VALID FOR 12 MONTHS FROM DATE OF BEING SEALED. TO THE BEST OF THE KNOWLEDGE OF THE ARCHITECTS OR ENGINEERS, SAID PLANS AND SPECIFICATIONS COMPLY WITH THE APPLICABLE MINIMUM BUILDING CODES AND THE APPLICABLE MINIMUM FIRE SAFETY STANDARDS. ALL DIMENSIONS AND JOB CONDITIONS SMALL BE VERIFIED BY THE CONTRACTOR, ANY AND ALL DISCREPANCIES SHALL BE REPORTED TO THE ARCHITECT PRIOR TO COMMENCEMENT OF CONSTRUCTION. ISSUE DATE REVIEW 02/22/11 PERMIT 02/23/11 IREV. IR,EV. mV. IREV. T+IESE DOCIM%, DES", NOTES, DETAILS AND SPEGIFICA11CM AND CONCEPTS ATE THE SOLE PRDPERTT OF FRAM DESW MG AND WALL NOT EE REPRODUCED, RE -USED OR COPIED FOR OTHER PROJI= M, IN WHOLE OR PARE WTHOUT THE WRiM CONSENT OF FRANC FRAM, ARCHITECT, AIA ALL RICM ARE RESERVED 9T THE ARCHM-W IN ACCORDANCE Wrn4 U& COPYRIGHT AND PATENT LAWS, Uw4UTHO MD RMPRODUCTION WILL. eE PROSECUTED TO THE FULL EXTENT OF R E LAU 0 0 N 0 Q v 1 0 T� vl WH�Q O U O UO V��N ORA FRANICLIN FRAZE, IV SHEET TITLE CONSTRUCT I ON DETAILS Bra 94 • in, r A- A-22 A-4 ... .... .... .. .... .... ... .... .... ... ... .. A-8 A-10 B--1.1 ...................................... am ABOVE CEILING ELECTRICAL POWER PLAN E-1 j SCALE: 1/4" = 1'-0" NORTH 16 , r1 r 0 �J`Jv% ELECTRICAL LIGHTING PLAN E-1 J SCALE: 1/4" = 1'-0" ELECTRICAL RISER DIAGRAM NORTH � I % E-1 SCALE: NONE �- �-c �S' C7c,; ►� 5 1 ``�- - 7 I�►C art. 7ian.e� �lv�ida �1f� # 2795s ^ R �►aS t�hi � -� G`C 1C �� i t = Vincent C IL,ecjna d Pane .0. spx x s2Y Tampa, El pri ' ccJ+4L l 'W�L 7. nebis@V6=on.net DCH PROJECT NUMBER: 11-002 ISSUE DATE REVIEW 1 /27/11 PERMIT 1/27/11 REV. REV. REV. REV. THESE DOCUMENTS, DESIGNS, NOTES, DETAILS AND SPECIFICATIONS AND CONCEPTS ARE THE SOLE PROPERTY OF FRAZE DESIGN, INC. AND SHALL NOT BE REPRODUCED, RE -USED OR COPIED FOR OTHER PROJECTS, IN WHOLE OR PART WITHOUT THE WRITTEN CONSENT OF FRANK FRAZE, ARCHITECT, AIA. ALL RIGHTS ARE RESERVED BY THE ARCHITECT IN ACCORDANCE WITH U.S. COPYRIGHT AND PATENT LAWS. UNAUTHORIZED REPRODUCTION WILL BE PROSECUTED TO THE FULL EXTENT OF THE LAW. O O cV O �A w v 1 O � v 1 QA h--I N W IMP O 0 O ►� � � N PROFESSdO"ki,S AL • F�J s A Z. NQ :tea of Lu e 'Ll ♦ , • SIOt�P;o9�A� #totalal9s00 VINCENT C. DILEONARDO FLORIDA P.E. #58009 g � m z A N r u a RJ 00 A V M� w W W ao H� � M 00 N M t` N r- w 00 M � N J~ w � � . U o x w � w SHEET TITLE ELECTRICAL PLANS SHEET NUMBER NEW PANEL "A" SCHEDULE PANEL RATING: 200 LOCATION: BREAK VOLTS: 208 PHASE: 3 WIRE: 4 HZ: 60 MLO: 200 MAIN AIC: 22,000 BR.AIC: 10,000 ENCL: NEMA 1 MTG.: SURFACE DESCRIP. OF BRANCH BREAKER VA/PHASE CKT PHASE CKT VA/PHASE BREAKER BRANCH DESCRIP. OF W G C A P A B C A B C A P W G C LOAD SERVED NO. A B C NO. LOAD SERVED EXISTING RTU (4T) 10 10 3/4" 35 3 4,203 1 2 1,200 20 1 12 12 3/4" XRAY 1 - - - - - - -- - -- 4,203 3 4 1,200 20 1 12 12 3/4" XRAY 2 - - - - - - - - - - - - - - - - - - 4,203 5 6 1,200 20 1 12 12 3/4" XRAY 3 EXISTING RTU (5T) 8 10 3/4" 45 3 4,803 7 8 1,200 1 20 1 1 12 12 3/4" XRAY 4 - - - - - - - - - - - - - - - - - - 4,803 9 10 1,200 20 1 12 12 3/4" XRAY 5 --- --- - - - - - - - - 4,803 11 12 1,200 20 1 12 12 3/4" XRAY 6 AIR COMPRESSOR 12 12 3/4" 20 2 874 1 13 14 1,200 20 1 12 12 3/4" XRAY 7 - - - - - - -- - - - - - - 874 15 16 1,200 20 1 12 12 3/4" XRAY 8 VACUUM PUMP 12 12 3/4" 20 2 697 17 18 1,200 20 1 12 12 3/4" UC-1,2,3 - - - --- - - - - - - - - - - - - 697 19 20 1,200 20 1 12 12 3/4" UC-6,7,8 WATER HEATER 10 10 3/4" 30 2 2,250 21 22 800 20 1 12 12 3/4" UC-4,5 - - - - - - - - - - -- - - - 2,250 23 24 1,200 20 1 12 12 3/4" XRAY 9 STERILIZER 12 12 3/4" 20 1 1,200 25 26 1,200 20 1 12 12 3/4" TRIMMER AUTOCLAVE 12 12 3/4" 20 1 1,2001 27 28 600 20 1 12 12 3/4" WATER FILTER ULTRASONIC 12 12 3/4" 20 1 1 1,200 29 30 SPACE TOTAL VA/PHASE 11,777 13,330 13,153 6,000 5,000 4,800 TOTAL VA/PHASE 17,777 Oil 17,953 TOTAL VA NOTES: 1. AIC RATINGS ARE MINIMUM SYMMETRICAL AMOUNTS. REVERIFY AVAILABLE SHORT CIRCUIT WITH LOCAL UTILITY PRIOR TO PREPARING SUBMITTALS AND INCREASE CAPACITY AS NECESSARY. 2. PROVIDE HACR TYPE CIRCUIT BREAKERS FOR ALL ITEMS IN THIS PANEL. 3. NOTE THAT THIS SCHEDULE INDICATES NEW LOADS ONLY. OTHER EXISTING ITEMS MAY BE PRESENT - FIELD VERIFY. 4. ALL OUTLETS IN KITCHEN AREAS SHALL BE GFCI PROTECTED PER NEC. 5. * INDICATES EXISTING BRANCH CIRCUIT TO REMAIN. 6. DEMAND LOAD CALCULATION: ITEM LOAD FACTOR DEMAND LIGHTING 0 x 125% = 0.0 RECEPTS < 10,000 VA 0 x 100% = 0.0 RECEPTS > 10,000 VA 0 x 50% = 0.0 EQUIPMENT 27,D42 x 100% = 27,042.0 HVAC (GREATER) 27,018 x 100% = 27,018.0 TOTAL DEMAND LOAD (VA) = 54,060.0 TOTAL DEMAND AMPERES = 150.1 TOTAL CONNECTED AMPERES = 150.1 NEW PANEL "B" SCHEDULE PANEL RATING: 200 LOCATION: BREAK VOLTS: 208 PHASE: 3 WIRE: 4 HZ: 60 MLO: 200 MAIN AIC: 22,000 BR.AIC: 10,000 ENCL: NEMA 1 MTG.: SURFACE DESCRIP. OF BRANCH BREAKER VA/PHASE CKT PHASE CKT VA/PHASE BREAKER BRANCH DESCRIP. OF W G C A P A B C A B C A P W G C LOAD SERVED NO. A B C NO. LOAD SERVED REC. - TRIAGE 1 & 2 12 12 3/4" 20 1 1,080 1 2 1,500 20 1 10 10 3/4" MICROWAVE REC. - TRIAGE 3 & 4 12 12 3/4" 20 1 1,080 3 4 1,000 20 1 12 12 3/4" DISPOSER REC. - TRIAGE 5 & 6 12 12 3/4" 20 1 1,080 5 6 600 20 1 12 12 3/4" WATER COOLER REC. - TRIAGE 7 & 8 12 12 3/4" 20 1 1,080 7 8 1,200 20 1 12 1 12 3/4" REFRIGERATOR REC. - WAITING 12 12 3/4" 20 1 900 9 10 1,165 20 1 12 12 3/4" LTG. - LEFT REC. - BUSINESS OFF 12 12 3/4" 20 1 720 11 12 1,200 20 1 12 12 3/4" 1 LTG. - SIGN REC. - BATHROOMS 12 12 3/4" 20 1 5401 13 14 990 20 1 12 12 3/4" LTG. - RIGHT REC. - ADMIN 12 12 3/4" 20 1 720 15 16 1,790 20 1 12 12 3/4" LTG. - FRONT REC. - LAB 12 12 3/4" 20 1 720 17 18 1,440 20 1 12 12 3/4" REC. - CORRIDOR REC. - OFFICE 12 12 3/4" 20 1 540 19 20 20 1 - - - - - - - - - SPARE REC. - BREAK ROOM 12 12 3/4" 20 1 540 21 22 20 1 - - - - - - - - - SPARE REC. - STERIL 1 12 12 3/4" 20 1 540 23 24 SPACE REC. - NETWORK 1 12 12 3/4" 20 1 360 1 25 26 SPACE REC. - STERIL 2 12 12 3/4" 20 1 720 27 28 SPACE REC. - NETWORK 2 12 12 3/4" 20 1 1 1 360 29 30 SPACE TOTAL VA/PHASE 1 3,600 3,960 3,420 3,690 3,955 3,240 TOTAL VA/PHASE 7,290 7,915 6,660 TOTAL VA NOTES: 1. AIC RATINGS ARE MINIMUM SYMMETRICAL AMOUNTS. REVERIFY AVAILABLE SHORT CIRCUIT WITH LOCAL UTILITY PRIOR TO PREPARING SUBMITTALS AND INCREASE CAPACITY AS NECESSARY. 2. PROVIDE HACR TYPE CIRCUIT BREAKERS FOR ALL ITEMS IN THIS PANEL. 3. NOTE THAT THIS SCHEDULE INDICATES NEW LOADS ONLY. OTHER EXISTING ITEMS MAY BE PRESENT - FIELD VERIFY. 4. ALL OUTLETS IN KITCHEN AREAS SHALL BE GFCI PROTECTED PER NEC. 5. * INDICATES EXISTING BRANCH CIRCUIT TO REMAIN. 6. DEMAND LOAD CALCULATION: ITEM LOAD FACTOR DEMAND LIGHTING 5,145 x 125% = 6,431.3 RECEPTS < 10,000 VA 10,000 x 100% = 10,000.0 RECEPTS > 10,000 VA 2,420 x 50% = 1,210.0 EQUIPMENT 4,300 x 100% = 4,300.0 HVAC (GREATER) 0 x 100% = 0.0 TOTAL DEMAND LOAD (VA) = 21,941.3 TOTAL DEMAND AMPERES = 60.9 TOTAL CONNECTED AMPERES = 60.7 ELECTRICAL SPECIFICATIONS: 1. GENERAL A. PROVIDE ALL LABOR, MATERIALS, AND EQUIPMENT REQUIRED FOR A COMPLETE SYSTEM AS OUTLINED IN THE CONTRACT DRAWINGS AND THESE SPECIFICATIONS. B. NOTE THAT DRAWINGS ARE DIAGRAMMATIC ONLY AND INTENDED TO SHOW THE GENERAL ARRANGEMENT OF SYSTEMS, NOT EVERY MINUTE DETAIL. C. DO NOT SCALE PLANS. D. PROVIDE ALL NECESSARY FITTINGS, BOXES, TRANSITIONS, CONNECTORS, ETC. WHETHER SHOWN OR NOT ON PLANS. E. ALL WORK IS NEW UNLESS OTHERWISE NOTED. F. THESE PLANS REPRESENT THE DESIGN INTENT BASED ON INFORMATION AVAILABLE AT THE TIME OF DESIGN. ANY SUBSTANTIAL MODIFICATIONS OR ALTERATIONS MADE DURING THE CONSTRUCTION PHASE SHALL BE REPORTED TO THE ENGINEER PRIOR TO WORK. MODIFICATIONS MADE WITHOUT THE ENGINEER'S WRITTEN APPROVAL SHALL REMAIN THE RESPONSIBILITY OF THE CONTRACTOR. G. IN CASE OF ANY DISCREPANCIES BETWEEN THE DRAWINGS, SPECIFICATIONS, FIELD CONDITIONS, CODES, ETC. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO REFER ALL SUCH MATTERS TO THE ENGINEER IN WRITING IMMEDIATELY FOR RESOLUTION PRIOR TO EXECUTING ANY WORK. ANY WORK PERFORMED WITHOUT THE WRITTEN AUTHORIZATION OF THE ENGINEER SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. H. ALL WORK SHALL CONFORM TO THE FOLLOWING CODES (AS APPLICABLE) AS WELL AS ALL LOCAL REGULATIONS, ORDINANCES, AND AMENDMENTS : 2007 FLORIDA BUILDING CODE W/ 2009 SUPPLEMENT 2008 NFPA-70 NATIONAL ELECTRICAL CODE 2005 NFPA-72 NATIONAL FIRE ALARM CODE 2. SCOPE OF WORK PROVIDE A COMPLETE NEW ELECTRICAL SYSTEM, INCLUDING ELECTRICAL SERVICE, POWER, LIGHTING, SITE LIGHTING, ETC. 3. ITEMS FURNISHED BY CONTRACTOR IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE ALL MATERIALS, EQUIPMENT, AND ACCESSORIES NECESSARY TO MAKE A COMPLETE INSTALLATION. ALL EQUIPMENT SHALL BE STORED IN A SAFE, DRY PLACE IN THE MANUFACTURER'S ORIGINAL PACKAGING UNTIL READY FOR USE. THE OWNER SHALL NOT BE RESPONSIBLE FOR PROVIDING ANY PART OF THE PROJECT, UNLESS SPECIFICALLY NOTED. THE CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR PAYING ALL REQUIRED FEES, OBTAINING ALL PERMITS, AND ARRANGING FOR ALL INSPECTIONS, INCLUDING COORDINATION WITH AND SATISFYING ALL REQUIREMENTS OF THE ELECTRICAL UTILITY COMPANY(IES) AS MAY BE REQUIRED TO EXECUTE THIS SCOPE OF WORK. 4. WORK IN EXISTING BUILDINGS A. DO NOT USE POWDER DRIVEN FASTENERS OF ANY TYPE. B. ALL ITEMS REMOVED AND NOT RE -USED SHALL BE TURNED OVER TO THE OWNER. CONTRACTOR SHALL REMOVE ANY UNSATISFACTORY ITEMS FROM THE PROJECT SITE. C. SOME EXISTING ITEMS TO REMAIN WITHOUT WORK ARE SHOWN FOR CLARITY OR REFERENCE ONLY. NOTE THAT ADDITIONAL ITEMS WITHOUT WORK MAY ALSO BE PRESENT. D. DRAWINGS OF EXISTING SYSTEMS ARE BASED ON EXISTING DOCUMENTS AND FIELD CONDITIONS, SOME OF WHICH MAY BE UNVERIFIED. PRIOR TO SUBMITTING A BID, CONTRACTOR SHALL STUDY THE PLANS AND VISIT THE PROJECT SITE IN ORDER TO BECOME FAMILIAR WITH EXISTING CONDITIONS. ANY DISCREPANCIES IN THE CONTRACT DOCUMENTS WHICH COULD SIGNIFICANTLY IMPACT THE PROJECT BUDGET OR SCHEDULE MUST BE REPORTED TO THE ENGINEER IN WRITING IMMEDIATELY. FAILURE TO DO SO WILL NOT BE SUFFICIENT CAUSE FOR DELAYS OR CHANGES LATER IN THE PROJECT.. CHANGE ORDERS RESULTING FROM FAILURE TO PROPERLY INVESTIGATE EXISTING FIELD CONDITIONS WILL NOT BE ACCEPTED. ALL WORK IS NEW UNLESS OTHERWISE NOTED. E. MODIFICATIONS TO EXISTING SYSTEMS NECESSARY TO CONNECT TO NEW WORK SHALL BE CONSIDERED TO BE PART OF THE BASIC WORK OF THIS CONTRACT. F. COORDINATE ALL WORK SCHEDULES WITH THE OWNER TO MINIMIZE DISRUPTIONS TO EXISTING SYSTEMS OUTSIDE THIS SCOPE OF WORK. 5. COORDINATION ALL WORK ON THIS PROJECT SHALL BE COORDINATED WITH THE OWNER AND ALL OTHER TRADES PRIOR TO BEGINNING AY WORK OR ORDERING ANY MATERIALS. CONTRACTOR SHALL REVIEW PLANS OF ALL DISCIPLINES INVOLVED AND ADVISE THE ARCHITECT IN WRITING OF ANY CONFLICTS, CODE OR SAFETY ISSUES THAT MAY EXIST PRIOR TO ANY FABRICATION OR ORDERING OF EQUIPMENT. RESOLUTION OF SUCH CONFLICTS WHICH ARE NOT REPORTED PRIOR TO CONSTRUCTION SHALL REMAIN THE RESPONSIBILITY OF THE CONTRACTOR AND CHANGE ORDER PROPOSALS FOR SUCH WORK WILL NOT BE ACCEPTED. PROVIDE ROUTING AND OFFSETS NECESSARY TO AVOID CONFLICTS WITH STRUCTURE, FINISHES, AND WORK OF OTHERS. CONTRACTOR SHALL PROVIDE ALL CORE PENETRATIONS AND PATCHING FOR FLOOR PENETRATIONS. 6. DEVICE LOCATIONS A. INSTALL ALL DEVICES IN ACCESSIBLE LOCATIONS, EXCEPT AS SPECIFICALLY NOTED OR PROHIBITED BY NEC. B, PROVIDE MIN. 18x18 INCH PAINTED ALUMINUM ACCESS DOORS WITH FULL HINGE AND KEY, FOR ACCESS TO ALL ELECTRICAL DEVICES, PULL BOXES, JUNCTION BOXES, AND ACCESSORIES IN PLASTER, DRYWALL, OR INACCESSIBLE CEILINGS, OR IN WALLS. GROUP DEVICES AT A SINGLE LOCATION, AS AVAILABLE. C. ACCESS DOORS IN RATED WALLS OR CEILINGS SHALL HAVE A RATING AT LEAST EQUAL TO THE RATING OF THE WALL OR CEILING. D. ALL DEVICES, RACEWAYS, ETC. WHICH ARE EXPOSED SHALL BE PAINTED TO MATCH THE ADJACENT SURFACE OR AS DIRECTED BY THE ARCHITECT. E. ALL ELECTRICAL EQUIPMENT SHALL BE INSTALLED A MINIMUM OF 1'-O" ABOVE THE BASE FLOOD ELEVATION. 7. EQUIPMENT GENERAL ALL EQUIPMENT OF EACH TYPE SHALL BE BY ONE MANUFACTURER AND SHALL HAVE CHARACTERISTICS AS LISTED IN THE EQUIPMENT SCHEDULES. ALL EQUIPMENT SHALL BE UL LISTED, NO EXCEPTIONS ! SUBSTITUTIONS ARE ACCEPTABLE PROVIDED THAT THE SUBSTITUTED EQUIPMENT HAS EQUIVALENT CHARACTERISTICS AS THAT SCHEDULED AND IS PROVIDED BY AN ACCEPTABLE MANUFACTURER AS LISTED FOR THAT EQUIPMENT TYPE. CONTRACTOR SHALL SUBMIT PRODUCT DATA FOR ALL EQUIPMENT TO THE ENGINEER FOR APPROVAL PRIOR TO ORDERING. SUBMITTALS SHALL INCLUDE DIMENSIONS, WEIGHT, VOLTAGE, AMPERAGE, HORSEPOWER, POWER FACTOR, INTERRUPTING CAPACITY, ETC. 8. CONDUCTORS A. PROVIDE ONLY DUAL RATED THWN-2/THHN-2 COPPER CONDUCTORS. MINIMUM SIZE IS NUMBER 12 AWG B. CONDUCTORS SHALL HAVE COLORED INSULATION FOR IDENTIFICATION PURPOSES AS FOLLOWS: 240/208/120V 480 277V PHASE A BLACK BROWN PHASE B RED ORANGE PHASE C BLUE YELLOW NEUTRAL WHITE NATURAL GREY GROUND GREEN GREEN W/ YELLOW STRIPE C. GROUNDED CONDUCTORS WHICH CARRY OVER 250V TO GROUND SHALL BE TAGGED WITH VOLTAGE AT EACH TERMINATION POINT. D. DO NOT INSTALL MORE THAN THREE CURRENT CARRYING CONDUCTORS IN SINGLE RACEWAY (NOT INCLUDING NEUTRAL) WHICH WILL REQUIRE NEC TABLE 310-16 NOTE 8 DERATING. E. PHASE AND GROUNDING CONDUCTOR SIZES SHALL BE INCREASED AS NECESSARY TO ACCOUNT FOR VOLTAGE DROP. LIGHTING FIXTURE SCHEDULE TAG LAMPS FIXTURE NOTES QTY TYPE DESC. MOUNTING VOLTS/O/Hz VA 2x4 LENSED TROFFER A 2 FLUOR. 32W, T-8 GRID 120/1 /60 70 GRID MOUNTED HIGH EFF. ELEC. BALLAST DECORATIVE PENDENT B 1 CF 30W MR16 PENDENT 120/1/60 30 OVER DESK BY OWNER 6" RECESSED CAN WITH C 1 CIF 32W, TRT RECESSED 120/1/60 40 BAFFLE & DIFFUSE REFLECTOR HIGH EFF. EELC. BALLAST ROUND LENSED UTILITY D 1 INCAND. 60W A-19 SURFACE 120/1/60 60 LIGHT FOR MECH ROOM. COMBO EGRESS/EXIT SIGN X 1 LED 5W LED SURFACE 120/1/60 5 W/ RED LETTERS AND 90 MIN. BATTERY PACK 1. PROVIDE NORTH FACING PHOTOCELL AND LIGHTING CONTACTORS AS NECESSARY TO OPERATE L COMMON EXTERIOR LIGHT FIXTURES SIMULTANEOUSLY EXCEPT EXIT AND EGRESS LIGHTI G AL L ( LIGHTING). 2. EXIT SIGNS AND EGRESS LIGHTING SHALL HAVE 90 MINUTE BATTERY BACKUP AND SHALL NOT BE SWITCHED. 3. PROVIDE OCCUPANCY SENSORS OR TIME CLOCK FOR AUTOMATIC CONTROL IN ALL SPACES. PROVIDE NECESSARY ACCESSORIES SUCH AS RELAYS, CONTACTORS, SENSORS, OVERRIDES, ETC. 4. ALL EXTERIOR LIGHT FIXTURES SHALL BE DAMP OR WET LOCATION LISTED. 9. RACEWAYS A. INSTALL ALL WIRING ABOVE GROUND IN METALLIC CONDUIT (EMT INDOORS, RGS OUTDOORS OR IN EXPOSED LOCATIONS). B. ALL EXPOSED RACEWAYS SHALL BE RUN PARALLEL TO WALLS OR CEILINGS AND SHALL BE PAINTED TO MATCH ADJACENT SURFACES OR AS DIRECTED BY THE OWNER. C. WHERE MULTIPLE RACEWAYS ARE RUN EXPOSED, RUN ALL RACEWAYS SQUARE AND PARALLEL IN A NEAT AND ORDERLY MANNER. D. MAKE FINAL CONNECTIONS (NOT MORE THAN 6'-0" LONG) TO ALL EQUIPMENT WITH FLEXIBLE METALLIC CONDUIT (DRY LOCATIONS) OR LIQUID TIGHT FLEXIBLE METALLIC CONDUIT (DAMP OR WET LOCATIONS). E. INSTALL ALL WIRING BELOW GROUND IN RIGID NON-METALLIC CONDUIT (SCHEDULE 40 PVC). ALL EXTERIOR NONMETALLIC CONDUITS SHALL BE UV RESISTANT. ALL CONDUITS RUN BELOW GROUND SHALL BE INSTALLED ACCORDING TO NEC300-5. F. TYPE MC CABLE MAY BE USED AS AN ALTERNATIVE TO CONDUCTORS IN METAL RACEWAY IN DRY INDOOR LOCATIONS, PROVIDED IT IS INSTALLED PER NEC AND APPROVED BY THE AUTHORITY HAVING JURISDICTION. G. METALLIC CONDUITS SHALL NOT BE USED AS GROUNDING CONDUCTORS. PROVIDE A SEPARATE GROUNDING CONDUCTOR IN ALL METALLIC CONDUITS, BONDED AT BOTH ENDS PER NEC. 10. GROUNDING A. ALL ELECTRICAL SYSTEMS SHALL BE PROPERLY GROUNDED PER NEC 250, B. EXPOSED GROUNDING ELECTRODE CONDUCTORS SHALL BE PROTECTED BY RIGID NONMETALLIC CONDUITS, MIN SIZE = J". C. PROVIDE GROUNDING ELECTRODE CONDUCTORS TO DRIVEN GROUND RODS AT THE BASE OF ALL LIGHT POLES, REMOTE BUILDINGS, OR REMOTE EQUIPMENT. D. ALL METAL ITEMS OF THE ELECTRICAL SYSTEM INCLUDING RACEWAYS, BOXES, FIXTURES, ETC. SHALL BE BONDED AND PROPERLY GROUNDED. 11. SWITCHBOARDS AND PANEL BOARDS A. PROVIDE SWITCHBOARDS AND PANEL BOARDS, SIZE AND ARRANGEMENT AS INDICATED ON PLANS AND SCHEDULES. B. MOUNT PANEL BOARDS NOT MORE THAN 48" A.F.F. TO CENTER. C. ENCLOSURES SHALL BE SUITABLE FOR THE ENVIRONMENT IN WHICH THEY ARE INSTALLED (NEMA 1 INDOORS, NEMA 3R OUTDOORS, ETC.) D. PROVIDE A TYPEWRITTEN PANEL SCHEDULE IDENTIFYING THE FUNCTION OF ALL CIRCUIT BREAKERS IN A CLEAR PLASTIC SLEEVE PERMANENTLY ATTACHED TO THE PANEL BOARD COVER. E. ALL SWITCHBOARDS AND PANEL BOARDS SHALL HAVE A THERMOPLASTIC IDENTIFYING NAMEPLATE PERMANENTLY AFFIXED TO THE FRONT OR COVER. F. PROVIDE ONE 1" EMPTY CONDUIT FROM PANEL TO 6" ABOVE CEILING FOR EVERY (3) SPARES OR SPACES. G. PANEL BOARDS AND SWITCHBOARDS BY: SQUARE D, CUTLER HAMMER, OR GE. 12. CIRCUIT BREAKERS A. ALL CIRCUIT BREAKERS SHALL BE BY A SINGLE MANUFACTURER, WITH SAME STYLE AND WITHSTAND RATING TO MATCH THE PANEL IN WHICH THEY ARE INSTALLED. B. PROVIDE MULTIPLE POLE CIRCUIT BREAKERS FOR MULTIPLE POLE CIRCUITS. HANDLE TIES ARE NOT PERMITTED. C. PROVIDE HACR TYPE CIRCUIT BREAKERS FOR ALL HVAC EQUIPMENT AND WATER HEATERS. D. PROVIDE GROUND FAULT CIRCUIT INTERRUPTER BREAKERS FOR ALL OUTDOOR, BATHROOM, AND KITCHEN BRANCH CIRCUITS WHICH DO NOT UTILIZE GFCI RECEPTACLES, OR AS OTHERWISE REQUIRED BY THE AUTHORITY HAVING JURISDICTION. E. NOT USED. F. NOT USED. G. PROVIDE INVERSE TIME CIRCUIT BREAKERS FOR MOTORS UNLESS SPECIFIED OTHERWISE. H. CIRCUIT BREAKERS SHALL BE PROVIDED WITH INDICATING ON/OFF HANDLES. J. CIRCUIT BREAKERS FOR FIRE ALARMS SHALL BE LOCKABLE. K. CIRCUIT BREAKERS BY: SQUARE D, CUTLER HAMMER, OR GE. 13. DEVICES A. PROVIDE GALVANIZED STEEL BOXES FOR ALL DEVICES IN EXPOSED LOCATIONS OR RECESSED INTO RATED WALLS. B. PROVIDE THERMOPLASTIC OR GALVANIZED STEEL BOXES FOR ALL DEVICES TO BE RECESSED INTO NON -RATED WALLS. C. FINISH OF ALL DEVICES AND COVER PLATES SHALL BE AS DIRECTED BY THE OWNER IN WRITING PRIOR TO ORDERING. D. ALL RECEPTACLES SHALL BE OF THE GROUNDING TYPE. E. ALL RECEPTACLES SHALL BE 20 AMP, 120 VOLT RATED, COMMERCIAL GRADE. F. PROVIDE DISCONNECT SWITCHES (WITH OR WITHOUT FUSES AS SPECIFIED) IN ENCLOSURES SUITABLE FOR THE ENVIRONMENT IN WHICH THEY ARE INSTALLED (NEMA 1 INDOORS, NEMA 3R OUTDOORS & AT WATER HEATER, ETC.) G. ALL SWITCHES AND RECEPTACLES BY LEVITON, GE, OR EQUIVALENT. H. PROVIDE GFCI RECEPTACLES IN ALL KITCHENS, BATHROOMS, GARAGES, OUTSIDE, OR WHEREVER ELSE SHOWN ON DRAWINGS. LABEL ALL DEVICES DOWNSTREAM OF GFCI DEVICE AS "GFCI PROTECTED". PROVIDE AT LEAST ONE DUPLEX GFCI PROTECTED RECEPTACLE IN A WEATHERPROOF ENCLOSURE WITHIN TWENTY FIVE (25) FEET OF ALL ROOF OR GRADE MOUNTED EXTERIOR HVAC EQUIPMENT. J. FOR GFCI RECEPTACLES NOT ON A DEDICATED BRANCH CIRCUIT (SUCH AS OUTDOOR RECEPTACLES CONNECTED TO THE NEAREST INTERIOR CIRCUIT), MAKE EVERY ATTEMPT TO LOCATE THE GFCI RECEPTACLE AT THE END OF THE CIRCUIT RUN SO AS TO MINIMIZE THE POSSIBILITY OF CAUSING NUISANCE POWER LOSS TO OTHER DEVICES WHEN THE GFCI DEVICE TRIPS. 14. LIGHTING A. ALL LIGHT FIXTURES SHALL BE THOSE DESCRIBED IN THE LIGHTING FIXTURE SCHEDULE OR THEIR EQUIVALENT AS APPROVED BY THE ENGINEER PRIOR TO ORDERING. IF ALTERNATE FIXTURES ARE USED, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO COORDINATE THEIR INSTALLATION DETAILS WITH ALL OTHER TRADES WITH REGARD TO SPACE REQUIRED, WIRING, POWER CONSUMPTION, ETC. B. LIGHTING BRANCH CIRCUITS SHALL NOT BE LOADED TO MORE THAN 80% OF THE CIRCUIT BREAKER AM PAC ITY. C. ALL LIGHT FIXTURES INSTALLED IN DAMP, WET, OR HAZARDOUS (CLASSIFIED) LOCATIONS SHALL BE LISTED FOR SUCH USE. D. INCANDESCENT LAMPS SHALL NOT BE USED EXCEPT FOR DIMMING PURPOSES OR AS OTHERWISE STATED ON PLANS OR PERMITTED BY THE AUTHORITY HAVING JURISDICTION. E. ALL FLUORESCENT OR HID LIGHT FIXTURES SHALL BE FUSED WITH ELECTRONIC BALLAST AS REQUIRED TO MEET THE SWITCHING REQUIREMENTS DESCRIBED ELSEWHERE IN THESE DOCUMENTS OR THE AUTHORITY HAVING JURISDICTION. PROVIDE MULTIPLE BALLASTS WHERE REQUIRED TO PROVIDE MULTIPLE LIGHTING LEVELS TO COMPLY WITH APPLICABLE ENERGY CODES. F. INTERIOR LIGHTING IN ALL BUILDINGS LARGER THAN 5,000 SQUARE FEET SHALL BE PROVIDED WITH AUTOMATIC CONTROLS. CONTROLS SHALL CONSIST OF A CENTRAL TIME -OF -DAY SCHEDULING CONTROLLER OR OCCUPANCY SENSORS LOCATED IN EACH SPACE. OCCUPANCY SENSORS SHALL BE LOCATED SO THE OCCUPANT CAN SEE THE CONTROLLED LIGHTING AND SHALL BE CAPABLE OF A 4 HOUR OVERRIDE. LIGHTING CONTROL ZONES SHALL NOT EXCEED 2,500 SQUARE FEET. G. PROVIDE TIME CLOCKS OR NORTH FACING PHOTOCELLS TO CONTROL ALL EXTERIOR LIGHTING CIRCUITS AUTOMATICALLY. PROVIDE LIGHTING CONTACTORS AS REQUIRED. H. ALL EXIT SIGNS AND EMERGENCY EGRESS LIGHTING SHALL NOT BE SWITCHED AND SHALL HAVE BATTERY BACKUP OR BE CONNECTED TO THE EMERGENCY POWER SYSTEM. 15. WARRANTIES AND MAINTENANCE A. ALL EQUIPMENT SHALL BE STARTED, TESTED, ADJUSTED, LUBRICATED, CLEANED, AND PLACED IN GOOD Of OPERATING CONDITION BY THE CONTRACTOR. CONTRACTOR SHALL GUARANTEE ALL EQUIPMENT, MATERIALS, AND < WORKMANSHIP TO BE FREE OF DEFECTS FOR A PERIOD OF ONE YEAR FROM THE DATE OF ACCEPTANCE BY Z THE OWNER AND THE CONTRACTOR SHALL REPAIR ANY SUCH DEFECTS AT NO COST TO THE OWNER. ALL EQUIPMENT INCLUDED IN THE PROJECT SHALL BE COVERED BY THE MANUFACTURER'S WARRANTY FOR THE DURATION OF THAT WARRANTY. COPIES OF ALL MANUFACTURER'S WARRANTIES AND CONTRACTOR WARRANTIES N SHALL BE PROVIDED TO THE OWNER AT FINAL ACCEPTANCE. < B. CONTRACTOR SHALL MEET WITH THE OWNER'S REPRESENTATIVE AND REVIEW ALL OPERATIONS AND MAINTENANCE OF ALL SYSTEMS. CONTRACTOR SHALL PROVIDE THE OWNER WITH BOUND COPIES OF ALL Z OPERATION AND MAINTENANCE MANUALS INCLUDING PARTS LISTS, MAINTENANCE SCHEDULES, ETC. < C. THE CONTRACTOR SHALL CONTINUALLY RECORD ANY AND ALL DEVIATIONS TO THE CONTRACT DOCUMENTS MADE DURING CONSTRUCTION AND PROVIDE A COMPLETE SET OF THESE RECORD DRAWINGS TO THE OWNER WITHIN 30 DAYS OF COMPLETION OF CONSTRUCTION. IF REQUIRED BY THE AUTHORITY HAVING JURISDICTION, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO SECURE THE SERVICES OF A LICENSED PROFESSIONAL z_ ENGINEER TO PROVIDE SIGNED AND SEALED RECORD DRAWINGS. z 16. TESTING w A. AT THE COMPLETION OF THE PROJECT, TEST ALL ELECTRICAL EQUIPMENT AND DEVICES FOR PROPER o OPERATION. TEST FOR GROUNDS AND SHORTS. REPORT ALL RESULTS TO THE ARCHITECT IN WRITING. REPLACE N ANY DEFECTIVE DEVICES OR EQUIPMENT. < B. TEST ALL FIRE ALARMS, GENERATORS, AND OTHER LIFE SAFETY EQUIPMENT IN THE PRESENCE OF THE ENGINEER AND THE FIRE OFFICIAL TO DEMONSTRATE OPERATION. MAKE ANY MODIFICATIONS NECESSARY AS o REQUIRED BY THE FIRE OFFICIAL AND REPAIR OR REPLACE ANY DEFECTIVE ITEMS AS NECESSARY. o N LD o U DCH PROJECT NUMBER: 11-002 ISSUE DATE REVIEW 1 /27/11 PERMIT 1 /27/11 REV. REV. REV. REV. THESE DOCUMENTS, DESIGNS, NOTES, DETAILS AND SPECIFICATIONS AND CONCEPTS ARE THE SOLE PROPERTY OF FRAZE DESIGN, INC. AND SHALL NOT BE REPRODUCED, RE -USED OR COPIED FOR OTHER PROJECTS, IN WHOLE OR PART WITHOUT THE WRITTEN CONSENT OF FRANK FRAZE, ARCHITECT, AIA. ALL RIGHTS ARE RESERVED BY THE ARCHITECT IN ACCORDANCE WITH U.S. COPYRIGHT AND PATENT LAWS. UNAUTHORIZED REPRODUCTION WILL BE PROSECUTED TO THE FULL EXTENT OF THE LAW. PROFESSIONAL SEAL 1L.EO/V ®® :® •®® c' SF ®R®• ®�� • 0� 4�.;s'fi 1 '�":,. sue• VINCEiNi6E)Jif NARDO FLORIDA P.E. #58009 \\ \ \MvONO '✓ 0 • • 1'rn I •• 04, 0 00 rq • SHEET TITLE ELECTRICAL SPECIFICATIONS SHEET NUMBER KEYED NOTES: O 1. EXISTING PACKAGED ROOFTOP UNIT WITH ELECTRIC HEAT TO REMAIN. CLEAN/SERVICE/REPAIR UNIT AS NECESSARY TO LIKE NEW CONDITION. RE -CONNECT NEW DUCTWORK AS SHOWN ON PLAN. CONNECT EXISING SUPPLY AIR SMOKE DETECTOR FOR AUTOMATIC UNIT SHUTDOWN AND CONNECT TO BUILDING FIRE ALARM (IF APPLICABLE). RE -BALANCE AIR FLOWS TO VALUES AS FOLLOWS: A) EXISTING 5 TON UNIT: SUPPLY AIR: 1,650 CFM RETURN AIR: 1,330 CFM OUTSIDE AIR: 320 CFM B) EXISTING 4 TON UNIT: SUPPLY AIR: 1,250 CFM RETURN AIR: 970 CFM OUTSIDE AIR: 280 CFM 2. PROVIDE NEW BATHROOM EXHAUST FAN AND 6" 0 METAL EXHAUST DUCT TO ROOF CAP. CONNECT FAN TO ROOM LIGHT SWITCH FOR SIMULTANEOUS OPERATION. 3. PROVIDE NEW DIGITAL 7-DAY TEMPERATURE CONTROLLER ON WALL WITH LOCKING CLEAR PLASTIC COVER. MOUNT CONTROLLER MAX. 48" A.F.F. 4. PROVIDE 18x6 LOUVER LOW IN DOOR FOR RETURN AIR FROM THIS ROOM. COORDINATE EXACT STYLE, FINISH, AND PLACEMENT WITH ARCH. 5. PROVIDE NEW GENERAL EXHAUST FAN AND 6" 0 METAL EXHAUST DUCT TO ROOF CAP. CONNECT FAN TO SEPARATE WALL SWITCH FOR OPERATION AS NEEDED. 6. PROVIDE NEW EXHAUST FAN WITH EXPLOSION PROOF MOTOR AND 6" 0 METAL EXHAUST DUCT TO ROOF CAP FOR GAS STORAGE ROOM. FAN SHALL RUN CONTINUOUSLY IN OCCUPIED MODE. ;_"� MECHANICAL PLAN M-1 I SCALE: 1/4" = 1'-0" NORTH MECHANICAL LEGEND AxB, ASUPPLY AIR DUCT, DIMENSION " A" SHOWN AxB, A4 RETURN AIR DUCT, DIMENSION "A" SHOWN FLEXIBLE DUCTWORK, SAME SIZE AS DIFFUSER NECK ---�- REFRIGERANT PIPING CONDENSATE DRAIN PIPING [Z—]® SUPPLY AIR DIFFUSERS RETURN AIR GRILLE ® EXHAUST AIR GRILLE �D FIRE DAMPER ---jVD VOLUME DAMPER m THERMOSTAT, 48" A.F.F. ROOFTOP EXHAUST FAN ® CEILING EXHAUST FAN HVAC EQUIPMENT TAG CU ---DENOTES EQUIPMENT TYPE 1 -DENOTES EQUIPMENT NUMBER AIR DEVICE TAG RG-1 DENOTES DEVICE TYPE 6'�� -DENOTES NECK/FLEX DUCT SIZE 60 --DENOTES AIR FLOW (CFM) DCH PROJECT NUMBER: 11-002 m U Z ¢ ¢ LP N ¢ Y z I z Z V) w 0 w N 0 O CV F__ c� 0- O U ISSUE DATE REVIEW 1 /27/11 PERMIT 1/27/11 _REV. REV. REV. REV. THESE DOCUMENTS, DESIGNS, NOTES, DETAILS AND SPECIFICATIONS AND CONCEPTS ARE THE SOLE PROPERTY OF FRAZE DESIGN, INC. AND SHALL NOT BE REPRODUCED, RE —USED OR COPIED FOR OTHER PROJECTS, IN WHOLE OR PART WITHOUT THE WRITTEN CONSENT OF FRANK FRAZE, ARCHITECT, AIA. ALL RIGHTS ARE RESERVED BY THE ARCHITECT IN ACCORDANCE WITH U.S. COPYRIGHT AND PATENT LAWS. UNAUTHORIZED REPRODUCTION WILL BE PROSECUTED TO THE FULL EXTENT OF THE LAW. 0 O cV O O Fri O W H evol �0 0 a O W �� 4-1 U �N PROFESSIONAL SEAL o�aoa�see®®�.�s a® �kLEO!V off® s U • e, .15QoO� • � a CJ °' • LU o 44 Iv�� '°•••• �i C, VINCENT 't°°UINARDO FLDRIDA P.E. #58009 in 00 t` 00 � M 00 O Z N � U aOO V W ac� V M i 00 N M t` N t` w z U 00 M N M W U-i-i � 0 w � w SHEET TITLE MECHANICAL PLANS SHEET NUMBER AIR BALANCE + OUTSIDE AIR CALCULATIONS BASED ON 2007 FLORIDA MECHANICAL CODE, TABLE 403.3 VENTILATION SPACE TYPE MEDICAL OFFICE AREA OF USABLE SPACE/PEOPLE 2327 SQFT # OF PEOPLE 7 /1000 SOFT MIN. VENT. MULTIPLIER 20 CFM/PERSON MIN. REQUIRED VENTILATION 325.8 CFM VENTILATION PROVIDED 600 CFM AIR BALANCE EXIST RTU-1 EXIST RTU-2 TOTAL SUPPLY AIR PRESSURIZATION 320 CFM 280 CFM 600 CFM 2900 CFM 20.00 EXHAUST AIR OUTLETS EF-1 (6) OA- EA 480 CFM 480 CFM OA x 100% EXHAUST FAN SCHEDULE TAG AREA SERVED FAN TYPE DRIVE TYPE AIRFLOW (CFM) E.S.P. ("W.C.) RPM FAN HP VOLTAGE (V/O/Hz) SONES DUCT SIZE MANUFACTURER MODEL ACCESS. EF-1 SINGLE TOILET CENT. DIRECT 80 0.10 900 54W 120/1 /60 2.5 4" 0 GREENHECK SP-B80 2,3,4,5,E STANDARD ACCESSORIES: NOTES 1 ROOF CURB 1. 2. 3. PROVIDE VIBRATION ISOLATORS WITH ALL FANS. CONNECT EF-1 TO OPERATE WITH WALL SWITCH & PROVIDE 5 MINUTE TIME DELAY (IF REQUIRED). PROVIDE EXPLOSION PROOF MOTOR FOR FAN IN GAS STORAGE CLOSET. 2 BACKDRAFT DAMPER 3 BIRDSCREEN 4 L6 WALL/ROOF CAP 5 DISCONNECT SPEED CONTROLLER AIR DEVICE SCHEDULE TAG FACE SIZE MATERIAL FINISH MANUFACTURER MODEL NOTES SD-1 2424 ALUM. WHITE PRICE ASCD 1,2,3 SD-2 12x12 ALUM. WHITE PRICE ASCD 1,2,3,4 RG-1 2424 ALUM. WHITE PRICE APFRF 1,2 1. REFER TO PLANS FOR ALL NECK SIZES. 2. NOISE CRITERIA NOT TO EXCEED 30 NC. 3. A DIFFUSERS ARE 4-WAY THROW UNLESS NOTED ALL CEILING N . 0 PLAN 4. FOR USE IN HARD CEILING OR DUCT, PROVIDE INTEGRAL VOLUME DAMPER. 5. SUBMIT TO ARCH. FOR APPROVAL PRIOR TO ORDERING. AIRFLOW 0 EXHAUST FAN INSTALLATION SCALE: NONE FLEXIBLE DUCT RUNOUT TO AIR DEVICE. PROVIDE CAN CONNECTION TO TRUNK RGLASS THREADED ROD HANGER TRAPEZE WITH VIBRATION ISOLATORS (TYP.) INTEGRAL BACKDRAFT DAMPER CEILING FAN CEILING GRILLE HANGER STRAP, 1 ", 22 GAUGE SHEET METAL. TYPICAL WRAP INSULATION ABOVE THE CEILING DIFFUSERS RADIUS NOT LESS THAN CONICAL SPIN -IN FITTING,Z THE FLEX DUCT WITH DAMPER DIAMETER (OMIT DAMPER IF PROVIDED IN DIFFUSER) 3 SHEET METAL SCREWS THRU HELIX OF FLEXIBLE DUCT, BAND CLAMP, TAPED FLEXIBLE DUCT, "THERMAFLEX MIKE" NOTE: OR "METALFLEX", INSULATED PROVIDE OPPOSED BLADE DAMPER DO NOT SAG OR KINK IN DRYWALL CEILINGS. FLEXIBLE DUCT RUNOUT SCALE: NONE MECHIANCAL SPECIFICATIONS: 1. GENERAL A. PROVIDE ALL LABOR, MATERIALS, AND EQUIPMENT REQUIRED FOR A COMPLETE SYSTEM AS OUTLINED IN THE CONTRACT DRAWINGS AND THESE SPECIFICATIONS. B. NOTE THAT DRAWINGS ARE DIAGRAMMATIC ONLY AND INTENDED TO SHOW THE GENERAL ARRANGEMENT OF SYSTEMS, NOT EVERY MINUTE DETAIL. C. DO NOT SCALE PLANS. D. PROVIDE ALL NECESSARY FITTINGS, TRANSITITONS, CONNECTORS, ETC. WHETHER SHOWN OR NOT ON PLANS. E. ALL WORK IS NEW UNLESS OTHERWISE NOTED. F. THESE PLANS REPRESENT THE DESIGN INTENT BASED ON INFORMATION AVAILABLE AT THE TIME OF DESIGN. ANY SUBSTANTIAL MODIFICATIONS OR ALTERATIONS MADE DURING THE CONSTRUCTION PHASE SHALL BE REPORTED TO THE ENGINEER PRIOR TO WORK. MODIFICATIONS MADE WITHOUT THE ENGINEER'S WRITTEN APPROVAL SHALL REMAIN THE RESPONSIBILITY OF THE CONTRACTOR. G. IN CASE OF ANY DISCREPANCIES BETWEEN THE DRAWINGS, SPECIFICATIONS, FIELD CONDITIONS, CODES, ETC. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO REFER ALL SUCH MATTERS TO THE ENGINEER IN WRITING IMMEDIATELY FOR RESOLUTION PRIOR TO EXECUTING ANY WORK. ANY WORK PERFORMED WITHOUT THE WRITTEN AUTHORIZATION OF THE ENGINEER SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. H. ALL WORK SHALL CONFORM TO THE FOLLOWING CODES (AS APPLICABLE) AS WELL AS ALL LOCAL REGULATIONS, ORDINANCES, AND AMENDMENTS: 2007 FLORIDA BUILDING CODE W/ 2009 SUPPLEMENT 2. SCOPE OF WORK PROVIDE A COMPLETE NEW MECHANICAL SYSTEM AS DESCRIBED BY THESE DOCUMENTS. 3. ITEMS FURNISHED BY CONTRACTOR IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE ALL MATERIALS, EQUIPMENT, AND ACCESSORIES NECESSARY TO MAKE A COMPLETE INSTALLATION, ALL EQUIPMENT SHALL BE STORED IN A SAFE, DRY PLACE IN THE MANUFACTURER'S ORIGINAL PACKAGING UNTIL READY FOR USE. THE OWNER SHALL NOT BE RESPONSIBLE FOR PROVIDING ANY PART OF THE PROJECT, UNLESS SPECIFICALLY NOTED. THE CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR PAYING ALL REQUIRED FEES, OBTAINING ALL PERMITS, AND ARRANGING FOR ALL INSPECTIONS, INCLUDING COORDINATION WITH AND SATISFYING ALL REQUIREMENTS OF ANY APPLICABLE UTILITY COMPANY(IES) AS MAY BE REQUIRED TO EXECUTE THIS SCOPE OF WORK. 4. WORK IN EXISTING BUILDINGS A. DO NOT USE POWDER DRIVEN FASTENERS OF ANY TYPE. B. ALL ITEMS REMOVED AND NOT RE -USED SHALL BE TURNED OVER TO THE OWNER. CONTRACTOR SHALL REMOVE ANY UNSATISFACTORY ITEMS FROM THE PROJECT SITE. C. SOME EXISTING ITEMS TO REMAIN WITHOUT WORK ARE SHOWN FOR CLARITY OR REFERENCE ONLY. NOTE THAT ADDITIONAL ITEMS WITHOUT WORK MAY ALSO BE PRESENT. D. DRAWINGS OF EXISTING SYSTEMS ARE BASED ON EXISTING DOCUMENTS AND FIELD CONDITIONS, SOME OF WHICH MAY BE UNVERIFIED. PRIOR TO SUBMITTING A BID, CONTRACTOR SHALL STUDY THE PLANS AND VISIT THE PROJECT SITE IN ORDER TO BECOME FAMILIAR WITH EXISTING CONDITIONS. ANY DISCREPANCIES IN THE CONTRACT DOCUMENTS WHICH COULD SIGNIFICANTLY IMPACT THE PROJECT BUDGET OR SCHEDULE MUST BE REPORTED TO THE ENGINEER IN WRITING IMMEDIATELY. FAILURE TO DO SO WILL NOT BE SUFFICIENT CAUSE FOR DELAYS OR CHANGES LATER IN THE PROJECT. CHANGE ORDERS RESULTING FROM FAILURE TO PROPERLY INVESTIGATE EXISTING FIELD CONDITIONS WILL NOT BE ACCEPTED. ALL WORK IS NEW UNLESS OTHERWISE NOTED. E. MODIFICATIONS TO EXISTING SYSTEMS NECESSARY TO CONNECT TO NEW WORK SHALL BE CONSIDERED TO BE PART OF THE BASIC WORK OF THIS CONTRACT. F. COORDINATE ALL WORK SCHEDULES WITH THE OWNER TO MINIMIZE DISRUPTIONS TO EXISTING SYSTEMS OUTSIDE THIS SCOPE OF WORK. 5. COORDINATION ALL WORK ON THIS PROJECT SHALL BE COORDINATED WITH THE OWNER AND ALL OTHER TRADES PRIOR TO BEGINNING AY WORK OR ORDERING ANY MATERIALS. CONTRACTOR SHALL REVIEW PLANS OF ALL DISCIPLINES INVOLVED AND ADVISE THE ARCHITECT IN X PRIOR TO ANY A S THAT MAY EXIST P I WRITING OF ANY CONFLICTS CODE OR SAFETY ISSUE FABRICATION OR ORDERING OF EQUIPMENT. RESOLUTION OF SUCH CONFLICTS WHICH ARE NOT REPORTED PRIOR TO CONSTRUCTION SHALL REMAIN THE RESPONSIBILITY OF THE CONTRACTOR AND CHANGE ORDER PROPOSALS FOR SUCH WORK WILL NOT BE ACCEPTED PROVIDE ROUTING AND OFFSETS NECESSARY TO AVOID CONFLICTS WITH STRUCTURE, FINISHES, AND WORK OF OTHERS. CONTRACTOR SHALL PROVIDE ALL CORE PENETRATIONS AND PATCHING FOR FLOOR PENETRATIONS. 6. BASIS OF DESIGN A. THE MECHANICAL CONTRACT DOCUMENTS HAVE BEEN PREPARED USING THE ASHRAE 97.5% DESIGN CRITERIA WITH THE FOLLOWING DESIGN CONDITIONS: INDOOR OUTDOOR SUMMER 75F DB/50% RH 92F DB/79F WB WINTER 72F DB 36F DB B. THE FOLLOWING BUILDING MATERIALS/INSULATION R-VALUES WERE USED IN THE HVAC CALCULATIONS. IF THE ACTUAL MATERIALS TO BE USED IN THE CONSTRUCTION PHASE (VERIFY WITH ARCH.) DIFFER FROM THESE SPECIFICATIONS, PARTICULARLY WITH REGARD TO THE ROOF, CONTACT THE ENGINEER PRIOR TO CONSTRUCTION IN WRITING IMMEDIATELY TO VERIFY THE ABILITY OF THE HVAC SYSTEMS TO EFFECTIVELY CONDITON THE SPACE: WALLS: BRICK & CONCRETE BLOCK WALL WITH R-4 BOARD INSULATION ROOF: FLAT BUILTUP ROOF WITH R-19 BATT INSULATION FLOOR: CONCRETE FLOOR SLAB ON GRADE, NO INSULATION GLASS: DOUBLE PANE TINTED GLASS WITH NO INTERNAL SHADES 7. EQUIPMENT GENERAL A. ALL EQUIPMENT OF EACH TYPE SHALL BE BY ONE MANUFACTURER AND SHALL HAVE CAPACITIES AND CHARACTERISTICS AS LISTED IN THE EQUIPMENT SCHEDULES. ALL EQUIPMENT SHALL BE UL LISTED, NO EXCEPTIONS! SUBSTITUTIONS ARE ACCEPTABLE PROVIDED THAT THE SUBSTITUTED EQUIPMENT HAS EQUIVALENT CAPACITY AS THAT SCHEDULED AND IS PROVIDED BY AN ACCEPTABLE MANUFACTURER AS LISTED FOR THAT EQUIPMENT TYPE. CONTRACTOR SHALL SUBMIT PRODUCT DATA FOR ALL EQUIPMENT TO THE ENGINEER FOR APPROVAL PRIOR TO ORDERING. SUBMITTALS SHALL INCLUDE DIMENSIONS, WEIGHT, CLEARANCES, FAN/PUMP CURVES, ELECTRICAL CHARACTERISTICS, SOUND LEVEL DATA, AND INSTALLATION DETAILS. B. UNLESS OTHERWISE NOTED, ALL MECHANICAL EQUIPMENT SHALL BE PROVIDED WITH VIBRATION ISOLATING MOUNTINGS TO PREVENT TRANSMISSION OF VIBRATION TO AND WITHIN THE BUILDING STRUCTURE. C. LOCATE ALL MECHANICAL EQUIPMENT SUCH THAT THE MANUFACTURER'S RECOMMENDED SERVICE CLEARANCE (INCLUDING CLEARANCE BETWEEN UNITS), AND THE FBC REQUIRED CLEARANCE TO COMBUSTIBLES IS MAINTAINED. D. INSTALL ALL EQUIPMENT IN STRICT ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS PLUMB, LEVEL, AND SQUARE IN LOCATIONS SHOWN ON PLANS. IF FIELD CONDITIONS PROHIBIT INSTALLATION OF EQUIPMENT IN LOCATIONS SHOWN, SUBMIT A WRITTEN REQUEST FOR INFORMATION TO THE ENGINEER IMMEDIATELY BEFORE PROCEEDING. 8. 9. 10. NOT USED. 11. FANS A. ALL FANS SHALL BEAR THE AMCA CERTIFIED RATINGS LABEL AND THE UL LABEL. ALL FAN MOTORS SHALL BE PROPERLY GROUNDED. B. ALL FANS SHALL HAVE A SOUND LEVEL RATING NOT IN EXCESS OF THAT SPECIFIED. C. ALL CENTRIFUGAL FANS SHALL HAVE TRUE WHEEL WITH INLET PERPENDICULAR TO DISCHARGE. D. ROOF MOUNTED FANS SHALL HAVE SPUN ALUMINUM HOUSINGS, ROOF CURB, AND DISCONNECT SWITCH MOUNTED INSIDE THE HOUSING. INTEGRAL BACKDRAFT DAMPERS SHALL BE TOTALLY CHATTERPROOF WITH NO METAL CONTACT. E. CEILING EXHAUST FANS SHALL HAVE ACOUSTICALLY LINED HOUSINGS AND SHALL BE PROVIDED WITH A TERMINAL BOX ON THE INSIDE OF THE HOUSING WITH CORD, PLUG, AND RECEPTACLE. ENTIRE FAN, MOTOR, AND WHEEL ASSEMBLY SHALL BE EASILY REMOVABLE WITHOUT DISTURBING THE HOUSING. F. ACCEPTABLE MANUFACTURERS ARE: GREENHECK, COOK, PENN, AND BROAN. 12, AIR DISTRIBUTION DEVICES A. PROVIDE AND INSTALL ALL AIR DEVICES IN LOCATIONS INDICATED ON DRAWINGS. VERIFY LOCATIONS AND CEILING TYPES WITH ARCH. PRIOR TO ORDERING. PROVIDE INTEGRAL VOLUME DAMPER FOR ALL AIR DEVICES LOCATED IN HARD CEILINGS AND INTEGRAL RADIATION DAMPER FOR ALL DEVICES LOCATED IN RATED CEILINGS. B. ALL AIR DEVICES SHALL BE ALUMINUM, EXCEPT THOSE INSTALLED IN RATED WALLS OR CEILINGS, OR IN AREAS WHERE SUBJECT TO DAMAGE, WHICH SHALL BE STEEL. FINISH OF ALL DEVICES SHALL BE WHITE UNLESS OTHERWISE NOTED ON PLANS. THE CONTRACTOR SHALL VERIFY FINISH COLOR AND STYLE OF ALL AIR DEVICES WITH THE ARCHITECT PRIOR TO ORDERING. C. ALL SURFACES OF DUCTWORK VISIBLE THROUGH AIR DEVICES SHALL BE PAINTED FLAT BLACK. D. ACCEPTABLE MANUFACTURERS ARE: TITUS, PRICE, METALAIRE, TUTTLE & BAILEY, AND BARBER COLEMAN. 13. DUCTWORK A. SMACNA'S "HVAC DUCT CONSTRUCTION STANDARDS" AND "FIBROUS GLASS DUCT CONSTRUCTION STANDARDS" SHALL BE CONSIDERED PART OF THE SPECIFICATIONS FOR THIS PROJECT. ANY WORK WHICH DOES NOT CONFORM TO THESE STANDARDS MAY BE REJECTED AT ANY TIME. B. ALL SUPPLY AND RETURN AIR DUCTWORK SHALL BE CONSTRUCTED OF 24 GAUGE GALVANIZED STEEL, CROSS -BROKEN, SEALED, AND 'EXTERNALLY INSULATED, SMACNA 1 INCH PRESSURE CLASS, SMACNA "A" SEAL CLASS. C. ALL SUPPLY AND RETURN AIR DUCTWORK SHALL BE CONSTRUCTED OF 1.5" THICK R-6 FOIL FACED FIBERGLASS DUCT BOARD, TAPED AND SEALED, BY KNAUF, JOHNS MANVILLE, OWENS CORNING, OR EQUIVALENT. D. ALL EXHAUST AIR DUCTWORK SHALL BE CONSTRUCTED OF GALVANIZED STEEL, SMACNA 1 INCH PRESSURE CLASS, SMACNA "A" SEAL CLASS. PROVIDE GRAVITY BACKDRAFT DAMPERS IN ALL EXHAUST DUCTS NEAR THE BUILDING EXIT POINT. E. ALL FLEXIBLE DUCTWORK SHALL BE THERMAFLEX TYPE M-KE R-6 OR EQUIVALENT. NO FLEX DUCT SHALL EXCEED 10'-0" IN LENGTH. F. NOT USED. G. NOT USED. H. DUCT DIMENSIONS SHOWN ARE CLEAR INSIDE DIMENSIONS. DUCT SIZE SUBSTITUTIONS ARE ACCEPTABLE ONLY IF THE CLEAR AREA SUBSTITUTED IS NOT LESS THAN THAT SHOWN AND THE DUCT ASPECT RATIO IS LESS THAN 4 TO 1. J. PROVIDE 45-DEGREE ENTRY ON ALL RECTANGULAR BRANCH CONNECTIONS. PROVIDE CONICAL TAPS WITH DAMPERS ON ALL ROUND BRANCH CONNECTIONS. K. PROVIDE LONG RADIUS ELBOWS, 3-PIECE ELBOWS, OR TURNING VANES AT ALL 90-DEGREE TURNS. SUBSTITUTION OF SQUARE ELBOWS IS NOT ACCEPTABLE. L. TEST ALL DUCTWORK FOR LEAKS PRIOR TO INSULATING. MAXIMUM LEAKAGE RATE IS 5 PERCENT. M. DUCTWORK SHALL NOT BE SUPPORTED BY ANYTHING OTHER THAN THE BUILDING STRUCTURE. LIKEWISE, NOTHING SHALL BE SUPPORTED BY THE DUCTWORK. N. PROVIDE VOLUME DAMPERS AT ALL BRANCH TAKE -OFFS OR AS INDICATED ON PLANS, PROVIDE VOLUME DAMPERS IN ALL AIR DEVICES LOCATED IN HARD CEILINGS. P. PROVIDE NORMALLY CLOSED MOTORIZED OUTSIDE AIR DAMPERS TO AUTOMATICALLY OPEN ONLY WHEN THE HEATING OR COOLING SYSTEMS (HEATER OR COMPRESSOR) IS OPERATING. OUTSIDE AIR DAMPERS SHALL NOT BE OPENED WHEN THE AIR HANDLING UNIT IS SET TO "FAN ON" WITHOUT THE REFRIGERANT CIRCUIT ENERGIZED. 13. DUCTWORK (CONTINUED) Q. PROVIDE FIRE PROOF FLEXIBLE CONNECTORS AT ALL DUCT CONNECTIONS TO FANS OR AIR HANDLING UNITS, UNLESS SPECIFICALLY NOTED OTHERWISE. R. PROVIDE SUPPLY AND RETURN AIR DUCT SMOKE DETECTORS FOR ALL AIR HANDLING SYSTEMS GREATER THAN 2,000 CFM OR AS NOTED ON PLANS. UPON ACTIVATION, SMOKE DETECTORS SHALL AUTOMATICALLY SHUT DOWN THE AIR HANDLING SYSTEM AND GENERATE A SIGNAL TO THE BUILDING FIRE ALARM (IF PROVIDED). PROVIDE A REMOTE KEY SWITCH WITH PILOT LIGHT IN CEILING BELOW UNIT FOR DETECTOR RESET. 14. PIPING A. REFRIGERANT PIPING SHALL BE TYPE "K" OR "ACR" COPPER PIPE WITH WROUGHT COPPER FITTINGS AND SILVER SOLDER JOINTS. REFRIGERANT LINES AND ALL ACCESSORIES SHALL BE SIZED, INSULATED, AND INSTALLED ACCORDING TO THE MANUFACTURER'S INSTRUCTIONS. THE MANUFACTURER SHALL BE MADE AWARE OF THE DISTANCE AND VERTICAL RISE OF REFRIGERANT PIPING BETWEEN EACH AIR HANDLER AND CONDENSING UNIT TO VERIFY PROPER OPERATION. B. CONDENSATE DRAIN PIPING SHALL BE SCHEDULE 40 PVC, PROVIDE A P-TRAP WITH CLEANOUT AT ALL DRAIN PAN LOCATIONS. ALL DRAIN PIPING SHALL BE AT LEAST THE SIZE OF THE COIL DRAIN CONNECTION. SLOPE ALL DRAIN PIPING A MINIMUM OF 1/8" PER FOOT TOWARDS THE DRAIN LOCATION. INSULATE ALL CONDENSATE DRAIN PIPING RUN IN UNCONDITIONED INTERIOR SPACES OR WHERE CONDENSATION MAY CAUSE DAMAGE WITH 3/4" CLOSED CELL FOAM INSULATION. C. WHERE MULTIPLE PIPES ARE RUN IN THE SAME AREA, ALL PIPING SHALL BE GROUPED AND RUN PARALLEL IN A NEAT AND ORDERLY MANNER. D. SUPPORT ALL PIPING ACCORDING TO THE FOLLOWING SPACING CRITERIA: HORIZONTAL(FT) VERTICAL (FT) CAST IRON 5 15 COPPER 6 10 CPVC 3 10 PVC 4 10 STEEL 8 10 15. NOT USED. 16. FILTERS & BELTS A. FILTERS SHALL BE OF A SIZE AND ARRANGEMENT SUITABLE TO THE REQUIREMENTS OF THE EQUIPMENT. FILTERS SHALL BE THE THROWAWAY TYPE AND PROVIDE 30% EFFICIENCY. B. BELTS SHALL BE REINFORCED RUBBER N" NOTCH TYPE SUITABLE FOR THE EQUIPMENT ON WHICH THEY ARE INSTALLED. C. AIR HANDLING UNITS SHALL NOT BE STARTED UNTIL ALL ROUGH CONSTRUCTION IS COMPLETE OR AS OTHERWISE DIRECTED BY THE MANUFACTURER CHANGE ALL AIR HANDLING UNIT FILTERS AT THE COMPLETION OF ALL CONSTRUCTION ACTIVITIES. D. PROVIDE 2 SPARE SETS OF FILTERS AND BELTS FOR ALL EQUIPMENT. 16. INSULATION A. INSULATE ALL SUPPLY, RETURN, AND OUTSIDE AIR METAL DUCTWORK WITH MINIMUM R-6 GLASS FIBER BLANKET TYPE, 2" THICK, WITH FACTORY APPLIED, FLAME RETARDANT, FOIL REINFORCED, KRAFT FACING EQUAL TO OWENS CORNING FIBERGLASS TYPE 150. APPLY IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. ALL INSULATION SHALL BE UL RATED 25/50/50. PROVIDE ALL ACCESSORIES NECESSARY TO MAKE A COMPLETE INSTALLATION SUCH AS TAPES, SEALANTS, FASTENERS, ETC. B. INSULATE ALL REFRIGERANT SUCTION PIPING AND INTERIOR CONDENSATE DRAIN PIPING WITH 3/4" THICK CLOSED CELL FOAM INSULATION SUCH AS ARMAFLEX TYPE AP OR EQUIVALENT. PROVIDE MANUFACTURER'S RECOMMENDED PAINT COATING ON EXTERIOR INSULATION TO PREVENT DECOMPOSITION. 17. TEMPERATURE CONTROL A. PROVIDE A THERMOSTAT FOR CONTROLLING EACH AIR CONDITIONING SYSTEM. ALL THERMOSTATS SHALL BE DIGITAL 7-DAY PROGRAMMABLE TYPE, LOW VOLTAGE, WALL MOUNTED, 48" ABOVE FINISHED FLOOR. THE MECHANICAL CONTRACTOR SHALL PROVIDE ALL LOW A PENETRATIONS BEHIND THE RMOSTATS WITH VOLTAGE WIRING SEAL EXPANDABLE FOAM INSULATION. THERMOSTATS SHALL HAVE SETTINGS FOR "HEAT" AND "COOL" TO PROVIDE COOLING AND STAGES OF HEATING AS LISTED IN THE SCHEDULE. THERMOSTATS SHALL ALSO HAVE FAN SETTINGS OF "ON" -"OFF" -"AUTO". B. ALL ELECTRIC HEATERS SHALL BE INTERLOCKED WITH AIR HANDLING UNITS TO PROVIDE HEATER SHUTDOWN IN THE EVENT OF FAN FAILURE. HEATER OPERATION SHALL REQUIRE AIRFLOW. C. ALL EQUIPMENT SHALL BE INTERLOCKED SUCH THAT HEATING AND COOLING OPERATIONS CAN NOT OCCUR SIMULTANEOUSLY, UNLESS EXPRESSLY NOTED ON PLANS AND ALLOWED BY FBC. 18. ELECTRICAL A. PROVIDE ALL STARTERS, CONTACTORS, RELAYS, CONTROLS, AND ACCESSORIES TO PROVIDE A COMPLETE POWER AND CONTROL WORKING SYSTEM. THE ELECTRICAL CONTRACTOR SHALL PROVIDE ALL DISCONNECT SWITCHES, CONDUIT, AND WIRING FOR ALL EQUIPMENT. ALL ELECTRICAL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE ELECTRICAL SPECIFICATIONS OF THESE DOCUMENTS AND THE NATIONAL ELECTRICAL CODE. B. THE MECHANICAL CONTRACTOR SHALL PROVIDE ALL WIRING DIAGRAMS, BE RESPONSIBLE FOR PROPER OPERATION OF THE COMPLETE SYSTEM, AND SHALL SUPERVISE ALL WIRING OF MECHANICAL EQUIPMENT. COORDINATE THE INSTALLATION OF ALL EQUIPMENT WITH AND PROVIDE ALL WIRING DIAGRAMS TO THE ELECTRICAL CONTRACTOR PRIOR TO THE ELECTRICAL CONTRACTOR BEGINNING ANY WORK C. NO WIRING OF ANY KIND SHALL BE EXPOSED IN FINISHED AREAS. WIRING TO ALL MOTORS OR OTHER ELECTRICAL EQUIPMENT SHALL HAVE HEATER ELEMENTS IN EACH PHASE WITH EITHER THE STARTER OR THE CONTACTOR. ALL MOTORS SHALL BE WOUND FOR THE VOLTAGE SPECIFIED AND SHALL HAVE A NAMEPLATE STATING THAT VOLTAGE AND CORRESPONDING AMPERES. WHERE MORE THAN ONE MOTOR OR OTHER EQUIPMENT IS CONTROLLED BY THE SAME CIRCUIT, OR WHEN THE LOAD EXCEEDS THE CAPACITY OF THE CONTROL EQUIPMENT, THE CONTRACTOR SHALL PROVIDE ALL NECESSARY CONTROLS AND RELAYS. 19. WARRANTIES AND MAINTENANCE A. ALL EQUIPMENT SHALL BE STARTED, TESTED, ADJUSTED, LUBRICATED, CLEANED, AND PLACED IN GOOD OPERATING CONDITION BY THE CONTRACTOR. CONTRACTOR SHALL GUARANTEE ALL EQUIPMENT, MATERIALS, AND WORKMANSHIP TO BE FREE OF DEFECTS FOR A PERIOD OF ONE YEAR FROM THE DATE OF ACCEPTANCE BY THE OWNER AND THE CONTRACTOR SHALL REPAIR ANY SUCH DEFECTS AT NO COST TO THE OWNER. ALL EQUIPMENT INCLUDED IN THE PROJECT SHALL BE COVERED BY THE MANUFACTURER'S WARRANTY FOR THE DURATION OF THAT WARRANTY. COPIES OF ALL MANUFACTURER'S WARRANTIES AND CONTRACTOR WARRANTIES SHALL BE PROVIDED TO THE OWNER AT FINAL ACCEPTANCE. B. CONTRACTOR SHALL MEET WITH THE OWNER'S REPRESENTATIVE AND REVIEW ALL OPERATIONS AND MAINTENANCE OF ALL SYSTEMS. CONTRACTOR SHALL PROVIDE THE OWNER WITH BOUND COPIES OF ALL OPERATION AND MAINTENANCE MANUALS INCLUDING PARTS LISTS, MAINTENANCE SCHEDULES, ETC. C. THE CONTRACTOR SHALL CONTINUALLY RECORD ANY AND ALL DEVIATIONS TO THE CONTRACT DOCUMENTS MADE DURING CONSTRUCTION AND PROVIDE A COMPLETE SET OF THESE RECORD DRAWINGS TO THE OWNER WITHIN 30 DAYS OF COMPLETION OF CONSTRUCTION. IF REQUIRED BY THE AUTHORITY HAVING JURISDICTION, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO SECURE THE SERVICES OF A LICENSED PROFESSIONAL ENGINEER TO PROVIDE SIGNED AND SEALED RECORD DRAWINGS. 20 TEST AND BALANCE A. THE MECHANICAL CONTRACTOR MAY TEST, ADJUST, AND BALANCE THE SYSTEM. ALL PROCEDURES SHALL BE PERFORMED IN ACCORDANCE WITH AABC OR NEBB STANDARDS. NOTE THAT FAN SELECTION POINTS REPRESENT DESIGN AIR FLOW RATES WITHOUT CONSIDERING DUCT LEAKAGE. PROVIDE ADDITIONAL DUCT SEALS AND ADJUST FANS TO COMPENSATE FOR DUCT LEAKAGE. PERFORM ALL TESTS NECESSARY TO ESTABLISH AND CONFIRM CAPACITY, QUALITY, AND COMPLETED STATUS OF WORK. B. SPECIFIC TESTS INCLUDE (BUT ARE NOT LIMITED TO): TEST & ADJUST SUPPLY FAN RPM TO DESIGN REQUIREMENTS. TEST & RECORD MOTOR LOAD AMPERES. DO NOT EXCEED NAMEPLATE RATING.IFIC TEST & RECORD SYSTEM STATIC PRESSURES. TEST & RECORD INDOOR COIL ENTERING & LEAVING AIR CONDITIONS. TEST & RECORD INDOOR COIL LEAVING AIR CONDITIONS. TEST & ADJUST EACH AIR DISTRIBUTION DEVICE TO PROVIDE AIRFLOW WITHIN 10 PERCENT OF DESIGN. TEST & VERIFY OPERATION OF ALL ELECTRIC HEATERS. DCH PROJECT NUMBER: 11-002' TO THE BEST OF THE KNOWLEDGE OF THE ARCHITECTS AND ENGINEERS, SAID PLANS AND SPECIFICATIONS COMPLY WITH THE 2007 FLORIDA BUILDING CODE WITH 2O09 SUPPLEMENTS AND THE APPLICABLE MINIMUM FIRE SAFETY STANDARDS, ALL DIMENSIONS AND JOB CONDITIONS SHALL BE VERIFIED BY THE CONTRACTOR, ANY AND ALL DISCREPANCIES SHALL BE REPORTED TO THE ARCHITECT PRIOR TO COMMENCEMENT OF CONSTRUCTION. THE DRAWINGS & DESIGN ARE VALID FOR 12 MONTHS FROM DATE OF ORIGINAL SEAL. m U z w N G✓ w z a✓ w I d z z w 0 w N 0 0 N 0 r a 0 c-) ISSUE DATE REVIEW 1 /27/11 PERMIT 1/27/11 REV. REV. REV. REV. THESE DOCUMENTS, DESIGNS, NOTES, DETAILS AND SPECIFICATIONS AND CONCEPTS ARE THE SOLE PROPERTY OF FRAZE DESIGN, INC. AND SHALL NOT BE REPRODUCED, RE -USED OR COPIED FOR OTHER PROJECTS, IN WHOLE OR PART WITHOUT THE WRITTEN CONSENT OF FRANK FRAZE, ARCHITECT, AIA. ALL RIGHTS ARE RESERVED BY THE ARCHITECT IN ACCORDANCE WITH U.S. COPYRIGHT AND PATENT LAWS. UNAUTHORIZED REPRODUCTION WILL BE PROSECUTED TO THE FULL EXTENT OF THE LAW. PROFESSIONAL SEAL t� It co oL,EON s ,p m ® d NOcrll •- ()� ® w .rFL O��`am�®® • s mge ®e • � ®� VINCENT C"alLfi iApeo FLORIDA P.E. #58009 k �! u • k _fflN - ----------- s • SHEET TITLE MECHANICAL SPECIFICATIONS SHEET NUMBER M_ 2 SANITARY WASTE + VENT PLAN P-1 j SCALE: 1/4" = 1'-0" NORTH .............. - - P-3 rl rl r1r1 LJ 1, RA l?J HW I I I P-3 .........................I ..... PLUMBING LEGEND NEW SANITARY WASTE PIPING NEW COLD WATER PIPING --- --- NEW HOT WATER PIPING --v--- v ---v -— NEW VENT PIPING Cp POINT OF COINNECTION GLOBE SHUTOFF VALVE 4MCH Cw-�- fL'kr--sp-F-s "D FT DCH PROJECT NUMBER: 11-002 Tll TI Ir ❑11T !lI TI IC 11AI AUll rnnr nr TI I A1111 II TrlTC` A A I I m Q U Z Q Q LLI N L.� Y Z Q Of L.L— I U Z Z U N Lil LLJ N Q Li CD 0 N f- 2 CD CL O U ISSUE DATE REVIEW 1 /27/11 PERMIT 1/27/11 REV. REV. REV. REV. THESE DOCUMENTS, DESIGNS, NOTES, DETAILS AND SPECIFICATIONS AND CONCEPTS ARE THE SOLE PROPERTY OF FRAZE DESIGN, INC. AND SHALL NOT BE REPRODUCED, RE —USED OR COPIED FOR OTHER PROJECTS, IN WHOLE OR PART WITHOUT THE WRITTEN CONSENT OF FRANK FRAZE, ARCHITECT, AIA. ALL RIGHTS ARE RESERVED BY THE ARCHITECT IN ACCORDANCE WITH U.S. COPYRIGHT AND PATENT LAWS. UNAUTHORIZED REPRODUCTION WILL BE PROSECUTED TO THE FULL EXTENT OF THE LAW, PROFESSIONAL SEAL etne�ps ,gB gym...., ®�►® m at® ®� � v a .: ze mP. m g+ .. .-: CA • • • • • • J f 00 ._ • • • SHEET PLUMBING TITLE PLANS SHEET NUMBER No P-3 �. �, P-3 I �, -2„ I I ' 2 2„ r/ 4„ _P _--1 2' T` I .„ P-2 FCO I ` t- > `. I � ` I > I � J' ` . EXIST ` 2" 3" VTR 4„ 2„ (, 2„ I v'' I 4" I 2" I I I 2.. \ P-4 4" / PT 1 � EXIST I 3" VTR I �`. P-3 4„ J 2 4„ J ' 4„ P-1 I P-2 2n „ I 2 `� > ' • I I` P-3 �� 2„ , 2 > > `� I I I ' P-3 FCO )" 2 ' SANITARY WASTE + VENT RISER SCALE: NONE PLUMBING SPECIFICATIONS: 1. GENERAL A. PROVIDE ALL LABOR, MATERIALS, AND EQUIPMENT REQUIRED FOR A COMPLETE SYSTEM AS OUTLINED IN THE CONTRACT DRAWINGS AND THESE SPECIFICATIONS. B. NOTE THAT DRAWINGS ARE DIAGRAMMATIC ONLY AND INTENDED TO SHOW THE GENERAL ARRANGEMENT OF SYSTEMS, NOT EVERY MINUTE DETAIL. C. DO NOT SCALE PLANS, D. PROVIDE ALL NECESSARY FITTINGS, TRANSITITONS, CONNECTORS, ETC. WHETHER SHOWN OR NOT ON PLANS. E. ALL WORK IS NEW UNLESS OTHERWISE NOTED. F. THESE PLANS REPRESENT THE DESIGN INTENT BASED ON INFORMATION AVAILABLE AT THE TIME OF DESIGN. ANY SUBSTANTIAL MODIFICATIONS OR ALTERATIONS MADE DURING THE CONSTRUCTION PHASE SHALL BE REPORTED TO THE ENGINEER PRIOR TO WORK. MODIFICATIONS MADE WITHOUT THE ENGINEER'S WRITTEN APPROVAL SHALL REMAIN THE RESPONSIBILITY OF THE CONTRACTOR. G. IN CASE OF ANY DISCREPANCIES BETWEEN THE DRAWINGS, SPECIFICATIONS, FIELD CONDITIONS, CODES, ETC. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO REFER ALL SUCH MATTERS TO THE ENGINEER IN WRITING IMMEDIATELY FOR RESOLUTION PRIOR TO EXECUTING ANY WORK. ANY WORK PERFORMED WITHOUT THE WRITTEN AUTHORIZATION OF THE ENGINEER SHALL REMAIN THE RESPONSIBILITY OF THE CONTRACTOR. H. ALL WORK SHALL CONFORM TO THE FOLLOWING CODES (AS APPLICABLE) AS WELL AS ALL LOCAL REGULATIONS, ORDINANCES, AND AMENDMENTS: 2007 FLORIDA BUILDING CODE W /2009 SUPPLEMENT 2. SCOPE OF WORK PROVIDE A COMPLETE NEW PLUMBING SYSTEM AS DESCRIBED BY THESE DOCUMENTS. 3. ITEMS FURNISHED BY CONTRACTOR IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE ALL MATERIALS, EQUIPMENT, AND ACCESSORIES NECESSARY TO MAKE A COMPLETE INSTALLATION. ALL EQUIPMENT SHALL BE STORED IN A SAFE, DRY PLACE IN THE MANUFACTURER'S ORIGINAL PACKAGING UNTIL READY FOR USE. THE OWNER SHALL NOT BE RESPONSIBLE FOR PROVIDING ANY PART OF THE PROJECT, UNLESS SPECIFICALLY NOTED. THE CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR PAYING ALL REQUIRED FEES, OBTAINING ALL PERMITS, AND ARRANGING FOR ALL INSPECTIONS, INCLUDING COORDINATION WITH AND SATISFYING ALL REQUIREMENTS OF THE PLUMBING UTILITY COMPANY(IES) AS MAY BE REQUIRED TO EXECUTE THIS SCOPE OF WORK. 4, WORK IN EXISTING BUILDINGS A. DO NOT USE POWDER DRIVEN FASTENERS OF ANY TYPE. B. ALL ITEMS REMOVED AND NOT RE —USED SHALL BE TURNED OVER TO THE OWNER. CONTRACTOR SHALL REMOVE ANY UNSATISFACTORY ITEMS FROM THE PROJECT SITE. C. SOME EXISTING ITEMS TO REMAIN WITHOUT WORK ARE SHOWN FOR CLARITY OR REFERENCE ONLY. NOTE THAT ADDITIONAL ITEMS WITHOUT WORK MAY ALSO BE PRESENT. D. DRAWINGS OF EXISTING SYSTEMS ARE BASED ON EXISTING DOCUMENTS AND FIELD CONDITIONS, SOME OF WHICH MAY BE UNVERIFIED. PRIOR TO SUBMITTING A BID, CONTRACTOR SHALL STUDY THE PLANS AND VISIT THE PROJECT SITE IN ORDER TO BECOME FAMILIAR WITH EXISTING CONDITIONS. ANY DISCREPANCIES IN THE CONTRACT DOCUMENTS WHICH COULD SIGNIFICANTLY IMPACT THE PROJECT BUDGET OR SCHEDULE MUST BE REPORTED TO THE ENGINEER IN WRITING IMMEDIATELY. FAILURE TO DO SO WILL NOT BE SUFFICIENT CAUSE FOR DELAYS OR CHANGES LATER IN THE PROJECT. CHANGE ORDERS RESULTING FROM FAILURE TO PROPERLY INVESTIGATE EXISTING FIELD CONDITIONS WILL NOT BE ACCEPTED. ALL WORK IS NEW UNLESS OTHERWISE NOTED. E. MODIFICATIONS TO EXISTING SYSTEMS NECESSARY TO CONNECT TO NEW WORK SHALL BE CONSIDERED TO BE PART OF THE BASIC WORK OF THIS CONTRACT. F. COORDINATE ALL WORK SCHEDULES WITH THE OWNER TO MINIMIZE DISRUPTIONS TO EXISTING SYSTEMS OUTSIDE THIS SCOPE OF WORK. 5. COORDINATION ALL WORK ON THIS PROJECT SHALL BE COORDINATED WITH THE OWNER AND ALL OTHER TRADES PRIOR TO BEGINNING ANY WORK OR ORDERING ANY MATERIALS. CONTRACTOR SHALL REVIEW PLANS OF ALL DISCIPLINES INVOLVED AND ADVISE THE ARCHITECT IN WRITING OF ANY CONFLICTS, CODE OR SAFETY ISSUES THAT MAY EXIST PRIOR TO ANY FABRICATION OR ORDERING OF EQUIPMENT. RESOLUTION OF SUCH CONFLICTS WHICH ARE NOT REPORTED PRIOR TO CONSTRUCTION SHALL REMAIN THE RESPONSIBILITY OF THE CONTRACTOR AND CHANGE ORDER PROPOSALS FOR SUCH WORK WILL NOT BE ACCEPTED. PROVIDE ROUTING AND OFFSETS NECESSARY TO AVOID CONFLICTS WITH STRUCTURE, FINISHES, AND WORK OF OTHERS. CONTRACTOR SHALL PROVIDE ALL CORE PENETRATIONS AND PATCHING FOR FLOOR PENETRATIONS. 6. PLUMBING GENERAL A. ALL PLUMBING SERVICES TERMINATE 5'-0" FROM THE BUILDING EXTERIOR WALLS. B. NO LEAD OR ASBESTOS CONTAINING MATERIALS OF ANY KIND SHALL BE USED IN THE FABRICATION OF POTABLE WATER SUPPLY SYSTEMS. GALVANIZED STEEL PIPING SHALL NOT BE USED FOR POTABLE WATER SUPPLY PIPING. C. INSTALL ALL WORK IN COMPLIANCE WITH ADA REQUIREMENTS. D. PROVIDE "P" TRAPS WITH CLEANOUTS IN THE DRAINS OF ALL FIXTURES EXCEPT THOSE WITH INTERNAL TRAPS OR AS SPECIFICALLY NOTED ON PLANS. E. PROVIDE FLOOR DRAINS WITH TRAP PRIMERS IN ALL PUBLIC BATHROOMS. F. ALL PIPING SHALL BE CONCEALED IN WALLS, CHASES, CEILINGS, ETC. UNLESS SPECIFICALLY NOTED ON DRAWINGS. ANY PIPING OR ACCESSORIES THAT MUST BE EXPOSED SHALL HAVE A POLISHED CHROME FINISH. G. INSTALL ALL VALVES AND CONTROLS IN ACCESSIBLE LOCATIONS, EXCEPT AS SPECIFICALLY NOTED ON PLANS OR PROHIBITED BY CODE. H. PROVIDE MIN. 6x6 INCH PAINTED ALUMINUM ACCESS DOORS WITH FULL HINGE AND KEY, FOR ACCESS TO ALL VALVES, CONTROLS, AND ACCESSORIES CONCEALED IN PLASTER, TILE, DRYWALL, OR INACCESSIBLE CEILINGS, OR IN WALLS. GROUP DEVICES AT A SINGLE LOCATION, AS AVAILABLE. J. COORDINATE THE ELECTRICAL CHARACTERISTICS OF ALL ELECTRICAL EQUIPMENT WITH THE ELECTRICAL CONTRACTOR PRIOR TO ORDERING. L. PIPING SHALL NOT PASS THROUGH DUCTWORK OF ANY KIND UNLESS APPROVED BY THE ENGINEER. M. PIPING SHALL NOT BE RUN ABOVE ELECTRICAL PANELS THROUGH ELECTRICAL ROOMS OR ANY OTHER WATER SENSITIVE AREAS, EXCEPT AS SPECIFICALLY NOTED ON PLANS. 7. SANITARY WASTE & VENT PIPING A. ALL SANITARY WASTE & VENT PIPING ABOVE AND BELOW GROUND SHALL BE SCHEDULE 40 PVC. B. ALL SANITARY WASTE PIPING 3" TO 6" SHALL BE SLOPED AT NO LESS THAN 1/8" PER FOOT. ALL SANITARY WASTE 2 34" AND SMALLER SHALL BE SLOPED AT NO LESS THAN �1 " PER FOOT. C. THE MINIMUM SANITARY WASTE & VENT PIPE SIZE SHALL BE 1 �'A". VERIFY LOCATIONS AND INVERT ELEVATIONS OF ANY AND ALL EXISTING WASTE, VENT, AND STORM DRAIN PIPING PRIOR TO BEGINNING ANY WORK. 8. DOMESTIC WATER PIPING A. ALL DOMESTIC WATER PIPING ABOVE GROUND SHALL BE TYPE "L" COPPER WITH WROUGHT COPPER FITTINGS AND LEAD FREE SOLDER JOINTS. B. ALL DOMESTIC WATER PIPING BELOW GROUND OR SLAB SHALL BE TYPE "K" COPPER WITH WROUGHT COPPER FITTINGS AND NO JOINTS BELOW FLOORS. C, CPVC PIPING WITH CPVC FITTINGS AND PRIMED/GLUED JOINTS IS AN ACCEPTABLE SUBSTITUTE TO COPPER PIPING IF INSTALLED PER FBC AND APPROVED BY THE AUTHORITY HAVING JURISDICTION. D. ALL NEW WATER SUPPLY PIPING SHALL BE RUN OVERHEAD (DO NOT RUN WATER SUPPLY PIPING BELOW CONCRETE FLOOR SLABS) UNLESS SPECIFICALLY STATED ON PLANS OR AS ABSOLUTELY NECESSARY TO MATCH AN EXISTING INSTALLATION, E. THE MINIMUM DOMESTIC WATER PIPE SIZE SHALL BE F. ALL HOT WATER SUPPLY PIPING SHALL BE INSULATED WITH 1" THICK, MIN. R-6, CLOSED CELL FOAM INSULATION (ARMAFLEX OR EQUIVALENT). 10. VENTS A. ALL TRAPS OR TRAPPED FIXTURES SHALL BE PROVIDED WITH AN INDIVIDUAL VENT UNLESS OTHERWISE NOTED. B. PLUMBING VENTS SHALL NOT BE LOCATED LESS THAN 10'—D" FROM ANY OUTSIDE AIR INTAKE, WINDOW, OR DOOR. C. SLOPE ALL HORIZONTAL VENTS SUCH THAT WATER MAY DRAIN BACK INTO THE SANITARY SYSTEM. D. OFFSET ALL VTR'S AS REQUIRED WHETHER SHOWN OR NOT ON DRAWINGS. E. PROVIDE ALL VTR'S WITH 4 LB. HIGH BOOT LEAD FLASHING OR AS REQUIRED BY THE ROOFING MANUFACTURER. FLASHING SHALL EXTEND UPWARD AROUND THE PIPE AND TURN DOWN INSIDE THE PIPE. 11, WATER HEATERS A. THE MAXIMUM HOT WATER DISCHARGE TEMPERATURE SHALL NOT EXCEED 110-F, UNLESS OTHERWISE NOTED ON PLANS. B. PROVIDE ISOLATION VALVES AT THE INLET AND OUTLET OF ALL WATER HEATERS. C. PROVIDE A SEPARATE DISCONNECT SWITCH FOR ALL ELECTRIC WATER HEATERS OR A GAS SHUTOFF VALVE FOR ALL GAS WATER HEATERS. 12. VALVES & ACCESSORIES A. PROVIDE WATER HAMMER ARRESTORS OR AIR CHAMBERS AS REQUIRED TO ELIMINATE WATER HAMMER AND COMPLY WITH LOCAL REGULATIONS, PARTICULARLY AT ALL APPLIANCES OR DEVICES WITH QUICK —CLOSING VALVES. B. PROVIDE A MAIN SHUTOFF VALVE AT THE BUILDING'S DOMESTIC WATER SERVICE ENTRANCE. COLD WATER C. PROVIDE VACUUM BREAKERS FOR ALL SILLCOCKS, HOSE BIBBS, AND WALL HYDRANTS. D. PROVIDE CLEANOUTS AT ALL CHANGES OF DIRECTION OF MORE THAN 45 DEGREES OR EVERY 50 FEET OF SUPPLY STRAIGHT PIPE FOR ALL SANITARY WASTE AND STORM DRAIN PIPING. PROVIDE CLEANOUTS AT THE BASE OF ALL STACKS. PROVIDE A YARD CLEANOUT FLUSH WITH FINISHED GRADE WITHIN 5 FEET OF THE BUILDING SEWER VACUUM BREAKER GATE EXITING THE BUILDING. COORDINATE ALL CLEANOUT LOCATIONS WITH THE ARCHITECT PRIOR TO INSTALLATION. VALVE E, PROVIDE DIELECTRIC UNIONS AT ALL POINTS OF CONNECTION BETWEEN PIPES OF DISSIMILAR METALS. 36 WATTS OR EQUAL CHECK F. APPLY MIN. 20 MILS THICK SCOTCHWRAP (OR EQUIVALENT) VINYL TAPE COVERING OVER ALL STEEL OR VALVE COPPER WATER PIPING IN CONTACT WITH MASONRY OR CONCRETE. UNION G. PROVIDE CHROME PLATED ESCUTCHEONS WHERE PIPES PENETRATE ANY EXPOSED WALLS, PARTITIONS, ETC. TO COVER THE PENETRATION. 13, FIXTURES A. FIXTURES HAVE BEEN SELECTED TO ESTABLISH A STANDARD OF QUALITY AND SUBSTITUTIONS ARE NOT PERMITTED UNLESS SUBMITTED AND APPROVED PRIOR TO USE. B. ALL VITREOUS CHINA FIXTURES SHALL BE WHITE UNLESS OTHERWISE NOTED. T & P RELIEF C. SEE ARCHITECHTURAL PLANS FOR EXACT FIXTURE LOCATIONS AND MOUNTING HEIGHTS. D. ALL FIXTURES IN THE SAME BUILDING OR AREA SHALL HAVE IDENTICAL FAUCETS, ESCUTCHEONS, AND TRIM VALVE KITS, UNLESS SPECIFICALLY NOTED ON PLANS. E. INSTALL HOT WATER SUPPLY ON THE LEFT SIDE OF ALL FIXTURES, F. ALL LAVATORIES IN PUBLIC RESTROOMS SHALL HAVE 0.5 GPM FLOW RESTRICTING AERATORS. 3/4" T&P G. FLUSH CONTROLS SHALL BE INSTALLED ON THE WIDE SIDE OF ALL WATER CLOSET STALLS. H. PROVIDE CONCEALED ARM CARRIERS OR 200 PT BLOCKING WITH ALL WALL MOUNTED LAVATORIES, URINALS, TO PAN WATER CLOSETS, AND WATER COOLERS. CARRIERS OR BLOCKING SHALL WITHSTAND A MINIMUM VERTICAL LOAD OF 250 POUNDS ON THE FRONT OF THE FIXTURE, J. PROVIDE PROTECTIVE ANTI —MICROBIAL INSULATION ON THE SUPPLY SET AND WASTE DRAIN AND TRAP OF ALL 4" HEAT EXPANSION TANK HANDICAPPED LAVATORIES. TRAP AMTROL ST-5 K. ALL WATER CLOSETS SHALL BE THE ELONGATED TYPE WITH OPEN FRONT SEATS. SUSPEND FROM STRUCTURE W/ 14, SUPPORTS & PENETRATIONS MIN. 1t2" THREADED RODS & A. PROVIDE MANUFACTURED PIPE HANGERS, RODS, AND INSERTS OR CLAMPS FOR THE PROPER SUPPORT OF ALL PIPING. BAND IRON, TIE WIRE, OR WIRE STRAPPING ARE NOT ACCEPTABLE. ALL PIPES SHALL BE SUPPORTED UNISTRUT TRAPEZE. VERIFY W1 AT REGULAR INTERVALS. PIPE SWAY AND/OR VIBRATION SHALL NOT BE ACCEPTABLE. DO NOT HANG PIPING FROM STRUCTURAL & INCREASE AS ANYTHING OTHER THAN THE BUILDING STRUCTURE. NECESSARY. 1 PER CORNER, TYP. B. SUPPORT ALL PIPING ACCORDING TO THE FOLLOWING SPACING CRITERIA: HORIZONTAL(FT) VERTICAL (FT) WATER HEATER CAST IRON 5 15 COPPER 6 10 CPVC 3 10 PVC 4 10 STEEL 8 10 SERVICE C. PROVIDE PLASTIC OR RUBBER COATED ISOLATORS WHERE COPPER PIPING IS IN DIRECT CONTACT WITH OR - DRAIN VALVE SUPPORTED BY STEEL PIPE HANGERS. m 15. WARRANTIES AND MAINTENANCE C A. ALL FIXTURES SHALL BE TESTED, CLEANED, AND PLACED IN GOOD OPERATING CONDITION BY THE 1 1/2" EDGE CONTRACTOR. CONTRACTOR SHALL GUARANTEE ALL EQUIPMENT, MATERIALS, AND WORKMANSHIP TO BE FREE OF DEFECTS FOR A PERIOD OF ONE YEAR FROM THE DATE OF ACCEPTANCE BY THE OWNER AND THE CONTRACTOR SHALL REPAIR ANY SUCH DEFECTS AT NO COST TO THE OWNER. ALL EQUIPMENT INCLUDED IN THE PROJECT SHALL BE COVERED BY THE MANUFACTURER'S WARRANTY FOR THE DURATION OF THAT WARRANTY. COPIES OF SAFETY PAN ALL MANUFACTURER'S WARRANTIES AND CONTRACTOR WARRANTIES SHALL BE PROVIDED TO THE OWNER AT FINAL 1" DRAIN TO ACCEPTANCE. B. CONTRACTOR SHALL MEET WITH THE OWNER'S REPRESENTATIVE AND REVIEW ALL OPERATIONS AND STORM DRAIN OR MAINTENANCE OF ALL SYSTEMS. CONTRACTOR SHALL PROVIDE THE OWNER WITH BOUND COPIES OF ALL EXTERIOR OPERATION AND MAINTENANCE MANUALS INCLUDING PARTS LISTS, MAINTENANCE SCHEDULES, ETC. C. THE CONTRACTOR SHALL CONTINUALLY RECORD ANY AND ALL DEVIATIONS TO THE CONTRACT DOCUMENTS MADE DURING CONSTRUCTION AND PROVIDE A COMPLETE SET OF THESE RECORD DRAWINGS TO THE OWNER WITHIN 30 DAYS OF COMPLETION OF CONSTRUCTION. IF REQUIRED BY THE AUTHORITY HAVING JURISDICTION, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO SECURE THE SERVICES OF A LICENSED PROFESSIONAL ENGINEER TO PROVIDE SIGNED AND SEALED RECORD DRAWINGS. 16. TESTING A. AT THE COMPLETION OF THE PROJECT, TEST ALL PLUMBING SYSTEMS AND FIXTURES FOR PROPER OPERATION. TEST ALL PIPING FOR LEAKS ACCORDING TO FPC. REPORT ALL RESULTS TO THE ARCHITECT IN WRITING. REPLACE ANY DEFECTIVE DEVICES OR EQUIPMENT. WATER HEATER INSTALLATION P-2 I SCALE: NONE DCH PROJECT NUMBER: 11-002 TO THE BEST OF THE KNOWLEDGE OF THE ARCHITECTS AND ENGINEERS, SAID PLANS AND SPECIFICATIONS COMPLY WITH THE 2007 FLORIDA BUILDING CODE WITH 2O09 SUPPLEMENTS AND THE APPLICABLE MINIMUM FIRE SAFETY STANDARDS. ALL DIMENSIONS AND JOB CONDITIONS SHALL BE VERIFIED BY THE CONTRACTOR, ANY AND ALL DISCREPANCIES SHALL BE REPORTED TO THE ARCHITECT PRIOR TO COMMENCEMENT OF CONSTRUCTION. THE DRAWINGS & DESIGN ARE VALID FOR 12 MONTHS FROM DATE OF ORIGINAL SEAL. m Cam' <C U Z Q �P N Q Y z Q w I d z Z w 0 w N Q 0 O N r- CD O U ISSUE DATE REVIEW 1 /27/11 PERMIT 1127111 REV. REV. REV. REV. THESE DOCUMENTS, DESIGNS, NOTES, DETAILS AND SPECIFICATIONS AND CONCEPTS ARE THE SOLE PROPERTY OF FRAZE DESIGN, INC. AND SHALL NOT BE REPRODUCED, RE —USED OR COPIED FOR OTHER PROJECTS, IN WHOLE OR PART WITHOUT THE WRITTEN CONSENT OF FRANK FRAZE, ARCHITECT, AIA. ALL RIGHTS ARE RESERVED BY THE ARCHITECT IN ACCORDANCE WITH U.S. COPYRIGHT AND PATENT LAWS. UNAUTHORIZED REPRODUCTION WILL BE PROSECUTED TO THE FULL EXTENT OF THE LAW. PROFESSIONAL SEAL ee®°® E lost I 0 ®�® 'q 10 • i w F v VI` 4 5-`I'LEONARDO FLOR P. E. #58009 .. ONO ,1.- • • • • .. w SHEET PLUMBING TITLE SPECIFICATIONS SHEET NUMBER GENERAL NOTE: VERIFY ALL PIPE SIZES, EQUIPMENT LOCATIONS AND CONSTRUC-nOISLDETAILS WITH DENTAL EQUIPMENT SUPPLIER PRIOR TO ANY CONSTRUCTION ACTNRY OR QRDERING MATERIALS. IN CASE OF 1 MEDICAL GAS PLAN P-3 SCALE: 1/4" = 1'-0" ►1,12 C�liil MEDICAL GAS LEGEND AIR — AIR — D D D — N20 N20 N2 — N2 02 02 VAC VAC — -V--- V - - -V -- COMPRESSED AIR PIPING DRAIN PIPING NITROUS OXIDE PIPING NITROGEN PIPING OXYGEN PIPING VACUUM PIPING VENT PIPING KEYED NOTES: O 1. NEW MEDICAL AIR COMPRESSOR BY DENTAL EQUIPMENT SUPPLIER (DES). PROVIDE ALL OPTIONS AND ACCESSORIES AS REQUIRED BY DES. PROVIDE 2" PVC INTAKE PIPE TO ROOF CAP & MAINTAIN 10 FEET CLEARANCE FROM ALL EXHAUSTS. 2. NEW VACUUM PUMP BY DES. PROVIDE ALL OPTIONS AND ACCESSORIES AS REQUIRED BY DES. PROVIDE 2" PVC INTAKE PIPE TO ROOF CAP & MAINTAIN 10 FEET CLEARANCE FROM ALL EXHAUSTS. ROUTE DRAIN PIPE INDIRECT TO FLOOR DRAIN WITH MIN. 1 " AIR GAP. 3. NEW DENTAL UTILITY STATION BY DES. 4. NEW AIR OUTLET LOCATED ABOVE COUNTERTOP. 5. NEW VACUUM INLET LOCATED ABOVE COUNTERTOP. 6. NEW AREA ALARM BY DES. CONNECT POWER VIA CORD/PLUG TO RECEPTACLE LOCATED ABOVE CEILING. 7. NEW MASTER CONTROL VALVE BY DES. CONNECT POWER VIA CORD/PLUG TO RECEPTACLE LOCATED ABOVE CEILING. 8. NEW OXYGEN AND NITROUS OXIDE BOTTLE TANK STORAGE CLOSET. MANIFOLD TANKS TOGETHER ACCORDING TO DES DETAILS. PROVIDE FULLY LOUVERED CLOSET DOOR FOR VENTILATION TO BE PROVIDED BY FAN IN BREAK ROOM. MEDICAL GAS SPECIFICATIONS 1.GENERAL A.PROVIDE ALL LABOR, MATERIALS, AND EQUIPMENT REQUIRED FOR A COMPLETE SYSTEM AS OUTLINED IN THE CONTRACT DRAWINGS AND THESE SPECIFICATIONS. B. NOTE THAT DRAWINGS ARE DIAGRAMMATIC ONLY AND INTENDED TO SHOW THE GENERAL ARRANGEMENT OF SYSTEMS, NOT EVERY MINUTE DETAIL. C.DO NOT SCALE PLANS. D.PROVIDE ALL NECESSARY FITTINGS, TRANSITITONS, CONNECTORS, ETC. WHETHER SHOWN OR NOT ON PLANS. E.ALL WORK IS NEW UNLESS OTHERWISE NOTED. FALL WORK SHALL CONFORM TO THE FOLLOWING CODES (AS APPLICABLE) AS WELL AS ALL LOCAL REGULATIONS, ORDINANCES, AND AMENDMENTS: 2007 FLORIDA BUILDING CODE W/ 2009 SUPPLEMENT 2002 NFPA 99 2.SCOPE OF WORK PROVIDE NEW MEDICAL GAS PIPING, EQUIPMENT, AND ACCESSORIES AS SHOWN ON THIS PLAN AND THE DENTAL EQUIPMENT SUPPLY DRAWINGS. 3.ITEMS FURNISHED BY CONTRACTOR IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE ALL MATERIALS, EQUIPMENT, AND ACCESSORIES NECESSARY TO MAKE A COMPLETE INSTALLATION. ALL EQUIPMENT SHALL BE STORED IN A SAFE, DRY PLACE IN THE MANUFACTURER'S ORIGINAL PACKAGING UNTIL READY FOR USE. THE OWNER SHALL NOT BE RESPONSIBLE FOR PROVIDING ANY PART OF THE PROJECT, UNLESS SPECIFICALLY NOTED. THE CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR PAYING ALL REQUIRED FEES, OBTAINING ALL PERMITS, AND ARRANGING FOR ALL INSPECTIONS. 4.WORK IN EXISTING BUILDINGS A.DO NOT USE POWDER DRIVEN FASTENERS OF ANY TYPE. BALL ITEMS REMOVED AND NOT RE -USED SHALL BE TURNED OVER TO THE OWNER. CONTRACTOR SHALL REMOVE ANY UNSATISFACTORY ITEMS FROM THE PROJECT SITE. C.SOME EXISTING ITEMS TO REMAIN WITHOUT WORK ARE SHOWN FOR CLARITY OR REFERENCE ONLY. NOTE THAT ADDITIONAL ITEMS WITHOUT WORK MAY ALSO BE PRESENT. D.DRAWINGS OF EXISTING SYSTEMS ARE BASED ON EXISTING DOCUMENTS AND FIELD CONDITIONS, SOME OF WHICH MAY BE UNVERIFIED. PRIOR TO SUBMITTING A BID, CONTRACTOR SHALL STUDY THE PLANS AND VISIT THE PROJECT SITE IN ORDER TO BECOME FAMILIAR WITH EXISTING CONDITIONS. ANY DISCREPANCIES IN THE CONTRACT DOCUMENTS WHICH COULD SIGNIFICANTLY IMPACT THE PROJECT BUDGET OR SCHEDULE MUST BE REPORTED TO THE ENGINEER IN WRITING IMMEDIATELY. FAILURE TO DO SO WILL NOT BE SUFFICIENT CAUSE FOR DELAYS OR CHANGES LATER IN THE PROJECT. CHANGE ORDERS RESULTING FROM FAILURE TO PROPERLY INVESTIGATE EXISTING FIELD CONDITIONS WILL NOT BE ACCEPTED. ALL WORK IS NEW UNLESS OTHERWISE NOTED. E.MODIFICATIONS TO EXISTING SYSTEMS NECESSARY TO CONNECT TO NEW WORK SHALL BE CONSIDERED TO BE PART OF THE BASIC WORK OF THIS CONTRACT. F. COORDINATE ALL WORK SCHEDULES WITH THE OWNER TO MINIMIZE DISRUPTIONS TO EXISTING SYSTEMS OUTSIDE THIS SCOPE OF WORK. 5.000RDINATION ALL WORK ON THIS PROJECT SHALL BE COORDINATED WITH ALL OTHER TRADES. CONTRACTOR SHALL REVIEW PLANS OF ALL DISCIPLINES INVOLVED AND ADVISE THE ARCHITECT IN WRITING OF ANY CONFLICTS, CODE OR SAFETY ISSUES THAT MAY EXIST PRIOR TO ANY FABRICATION OR ORDERING OF EQUIPMENT. PROVIDE ROUTING AND OFFSETS NECESSARY TO AVOID CONFLICTS WITH STRUCTURE, FINISHES, AND WORK OF OTHERS. CONTRACTOR SHALL PROVIDE ALL CORE PENETRATIONS AND PATCHING FOR PIPING FLOOR PENETRATIONS. 6.MEDICAL GAS GENERAL A.ALL MEDICAL GAS SYSTEMS INSTALLATION SHALL BE COORDINATED WITH THE OWNER, ARCHITECT, AND DENTAL EQUIPMENT SUPPLIER PRIOR TO ROUGH IN. IN CASE OF CONFLICTS THE DENTAL EQUIPMENT SUPPLIER DRAWINGS & SPECS SHALL GOVERN. B.INSTALL ALL WORK IN COMPLIANCE WITH ADA REQUIREMENTS AS NECESSARY. CALL PIPING SHALL BE CONCEALED IN WALLS, FLOORS, CHASES, CEILINGS, ETC. UNLESS SPECIFICALLY NOTED ON DRAWINGS. ANY PIPING OR ACCESSORIES THAT MUST BE EXPOSED SHALL HAVE A POLISHED CHROME FINISH. D.000RDINATE THE ELECTRICAL CHARACTERISTICS OF ALL ELECTRICAL EQUIPMENT WITH THE ELECTRICAL CONTRACTOR PRIOR TO ORDERING. E.PROVIDE LABELS AT REGULAR INTERVALS FOR ALL PIPING ABOVE GROUND. LABELS SHALL STATE THE TYPE OF FLUID OR PIPE SERVICE AND FLOW DIRECTION. 7.MEDICAL GAS PIPING A.ALL MEDICAL GAS PIPING SHALL BE CONSTRUCTED OF OXYGEN GRADE TYPE "L" COPPER WITH SILVER SOLDERED JOINTS. BALL PIPING SHALL BE SIZED PER THE DRAWINGS OR NFPA 99, WHICHEVER SIZE IS GREATER. CALL VACUUM PIPING SHALL BE MIN. 3✓4" SIZE. D.PIPING FOR ALL OTHER GASES SHALL BE MIN 16" SIZE. E.ALL PIPING SHALL BE RUN BELOW FLOOR AS SHOWN TO INDICATED INLET & OUTLET LOCATIONS. FOR ALL PIPING BELOW FLOORS, MAKE EVERY ATTEMPT POSSIBLE TO MINIMIZE THE NUMBER OF JOINTS BELOW THE FLOOR. 8.MEDICAL GAS EQUIPMENT AND ACCESSORIES A.PROVIDE AND INSTALL ALL EQUIPMENT AS SPECIFIED BY THE MEDICAL OR DENTAL EQUIPMENT SUPPLIER. B.PROVIDE SHUTOFF VALVES AT ALL CONNECTIONS TO MEDICAL GAS EQUIPMENT. C.PROVIDE DISCONNECT SWITCHES WITH ALL ELECTRICAL EQUIPMENT, D.PROVIDE ZONE ISOLATION AND CONTROL VALVES AT LOCATIONS SPECIFIED ON DRAWINGS OR ELSEWHERE AS REQUIRED BY NFPA 99. A.MOUNT ALL WALL DEVICES MIN 42" A.F.F. OR 6" ABOVE COUNTER, UNLESS OTHERWISE NOTED ON DRAWINGS. COORDINATE EXACT LOCATION WITH OWNER, MEDICAL/DENTAL EQUIPMENT SUPPLIER, AND ARCHITECT PRIOR TO ROUGH IN. 9. PENETRATIONS A.ALL PENETRATIONS THROUGH RATED WALLS OR FLOORS SHALL BE SEALED WITH AN APPROVED FIREPROOFING TO MAINTAIN THE INTEGRITY OF THE WALL OR FLOOR. B.ALL PIPING PASSING THROUGH BUILDING STRUCTURE OR RATED WALLS OR FLOORS SHALL BE SLEEVED. C.ALL PIPE SLEEVES SHALL BE SIZED AND INSTALLED TO ALLOW FOR PIPE EXPANSION. D.SUBMIT ALL SLEEVE SIZES AND LOCATIONS TO THE STRUCTURAL ENGINEER FOR APPROVAL PRIOR TO STARTING WORK. 10. WARRANTIES AND MAINTENANCE A.ALL FIXTURES SHALL BE TESTED, CLEANED, AND PLACED IN GOOD OPERATING CONDITION BY THE CONTRACTOR. CONTRACTOR SHALL GUARANTEE ALL EQUIPMENT, MATERIALS, AND WORKMANSHIP TO BE FREE OF DEFECTS FOR A PERIOD OF ONE YEAR FROM THE DATE OF ACCEPTANCE BY THE OWNER AND THE CONTRACTOR SHALL REPAIR ANY SUCH DEFECTS AT NO COST TO THE OWNER. ALL EQUIPMENT INCLUDED IN THE PROJECT SHALL BE COVERED BY THE MANUFACTURER'S WARRANTY FOR THE DURATION OF THAT WARRANTY. COPIES OF ALL MANUFACTURER'S WARRANTIES AND CONTRACTOR WARRANTIES SHALL BE PROVIDED TO THE OWNER AT FINAL ACCEPTANCE. B.CONTRACTOR SHALL RECORD DRAWINGS DURING CONSTRUCTION AND NOTE LOCATIONS OF ANY OFFSETS OR OTHER DEVIATIONS FROM THE ORIGINAL CONTRACT DOCUMENTS. AT THE CLOSE OF THE PROJECT, CONTRACTOR SHALL PROVIDE A COPY OF THESE DRAWINGS TO THE OWNER AS "AS-BUILTS". DCH PROJECT NUMBER: 11-002 TO THE BEST OF THE KNOWLEDGE OF THE ARCHITECTS AND ENGINEERS, SAID PLANS AND SPECIFICATIONS COMPLY WITH THE 2007 FLORIDA BUILDING CODE WITH 2O09 SUPPLEMENTS AND THE APPLICABLE MINIMUM FIRE SAFETY STANDARDS. ALL DIMENSIONS AND JOB CONDITIONS SHALL BE VERIFIED BY THE CONTRACTOR, ANY AND ALL DISCREPANCIES SHALL BE REPORTED TO THE ARCHITECT PRIOR TO COMMENCEMENT OF CONSTRUCTION. THE DRAWINGS & DESIGN ARE VALID FOR 12 MONTHS FROM DATE OF ORIGINAL SEAL. ISSUE DATE REVIEW 1 /27/11 PERMIT 1 /27/11 REV. REV. REV, REV. THESE DOCUMENTS, DESIGNS, NOTES, DETAILS AND SPECIFICATIONS AND CONCEPTS ARE THE SOLE PROPERTY OF FRAZE DESIGN, INC. AND SHALL NOT BE REPRODUCED, RE -USED OR COPIED FOR OTHER PROJECTS, IN WHOLE OR PART WITHOUT THE WRITTEN CONSENT OF FRANK FRAZE, ARCHITECT, AIA. ALL RIGHTS ARE RESERVED BY THE ARCHITECT IN ACCORDANCE WITH U.S. COPYRIGHT AND PATENT LAWS. UNAUTHORIZED REPRODUCTION WILL BE PROSECUTED TO THE FULL EXTENT OF THE LAW. PROFESSIONAL SEAL ®�oottt®ieoo+ o®�® t LEOn j,(� 00 ��e 4 � • • • • ° e i�w®I�I e 1U .• NS�c ®v, O ° O e ® • $ ® (�I SOf ' 4U O•a VINE z �RDO FLO Gar *ji 009 W) 00 O o N � m V) M 00 � QI 00 z N U a 00 A w w W ao N M N w W E °�z b�A OO m � OD N m w � o� w � a SHEET TITLE MEDICAL GAS PLANS SHEET Pttttt>. NUMBER QUAD ELEC. BOX D-—Ul UTILITY CENTER 3)NOT TO SALE GENERAL NOTES: THIS DRAWING IS FOR INFORMATIONAL PURPOSES ONLY. CONSULT ACTUAL MANUFACTURER'S TEMPLATE WHEN INSTALLING EQUIPMENT. LOCAL REGULATIONS PROVIDE THAT LICENSED PLUMBERS AND ELECTRICIANS SHALL INSTALL UTILITIES. ALL PLUMBING AND ELECTRICAL MUST MAXIMUM HEIGHT CONFORM TO PREVAILING LOCAL CODES. OF OPENED VALVE- 6" AIR AND WATER: MANUALSHUT-OFP VALVES. VACUUM- 5/8-O.D. TUBE ELEC. - ALLOW V! OF 1/2" FLEX ELECTRICAL° I I 5VAC, 60 HZ, TO BE CONDUIT TO INSTALLED WITH GFCI PROTECTED EXTEND BEYOND RECEPTACLE OUTLETS, CHECK AMPERAGE STUB -UP FOR ELEC, REQUIREMENTS, HOOK-UPS CONNECTIONS: ALL NITROUS OXIDE LINES ARE 3/8!'O.D. ALL PIPING,O 02 ALL OXYGEN LINES ARE I /2'O.D, INLET HOSE BARB COPPER PIPING. USE D.I.S.S. FITTINGS TO INLET TO BAG TEE CONNECTST I UBS TO FLOWMETER. NOTE: D,I,S.S. FITTINGS MUST BE ACCESSIBLE. THIS IS A TYPICAL UNIT. REFER TO MANUFACTURER'S INSTALLATION LITERATURE TO VERIFY TOP VIEW REQUIREMENTS. CLEARANCE V-0 3/16" FORHHOSE 41/2 115/9, 3 t CD + z E' NITROUS OXYGEN m. L-- — — LEFT SIDE VIEW FRONT VIEW NITROUS OXIDE FLOWMETER NOT TO SCALE GENERAL NOTES:, THIS DRAWING IS FOR INFORMATIONAL PURPOSES ONLY. CONSULT ACTUAL MANUFACTURER'S TEMPLATE WHEN INSTALLING EQUIPMENT. LOCAL REGULATIONS PROVIDE THAT LICENSED PLUMBERS AND ELECTRICIANS SHALL INSTALL UTILITIES. ALL PLUMBING AND ELECTRICAL MUST CONFORM TO PREVAILING LOCAL CODES. WATER* 35-40 PSI AIR: 70-80 PSI 1/2" O.D. (1.27cm) COPPER TUBING WITH I /Z'NPT MALE FITTING. STUB -Up 1-112'(3.81cm) FIRQ MANISHED, FLOOR SURFACE. FLUSH ALL DEBRIS FROM LINE BEFORE INSTALLING VALVES, NOTE: AIR AND WATER SHUT-OFF VALVES CAN NOT EXTEND MORE THAN 6" ABOVE FINISHED FLOOR SURFACE, FULLY OPENED. VACUUM. WATER —AIR N20 02 5/6'O,D. (I .59trri) COPPER TUBING, TYPE L (.045 WALL THICKNESS), STUMP IlT (1.27cm) MIN., I" (2,54cm) FINISHED FLOOR SURFACE MAX FROM FINISHED FLOOR OR WALL SURFACE. ELBOW CONNECTION FURNISHED BY P&C TO BE SOLDERED IN PLACE. -----VACUUM' ELECTRICAL: STUB -UP WITH 1 /7'(1.27cm) FLEXIBLE CONDUIT FOR CONNECTION TO THE POWER STRIP. CIRCUIT SHOULD BE 120 VAC. DEDICATED 15 AMP. NODE: ELECTRICAL INSTALLATION MOST MEET ALL APPROPRIATE ELECTRICAL CODES, CONSULT ELECTRICAL CONTRACTOR TO PROVIDE A Ill 5 VAC RECEPTACLE. ISAL RI CABINET UTILITIES NOT TO SC ELECTRICAL CONTRACTOR IS USE 12 AWG WIRE BETWEEN CONTROL BOX AND RESPONSIBLE FOR FOLLOWING ALL X-RAY UNIT FOR TOTAL WIRE LENGTH UP TO 50 FEET. LOCAL CODES FOR ROUGH INSTALLATION. HENRY SCHEIN TO 10 AWG WIRE IS REQUIRED WHEN WIRE LENGTH IS Q- MAKE FINAL CONNECTIONS. BETWEEN 50-75 FEET, ELECTRICIAN TO PROVIDE A FLUSH -MOUNTED SINGLE GANG JUNCTION BOX & 3/4!'CONDUIT W/ PULL -WIRE FROM CONTROL BOX TO X-RAY UNIT. POWER FROM BUILDING MOUNTING PLATE. CONTROL ELECTRICAL PANEL. 120V, BOX CAN BE MOUNTED DEDICTATED 15A CIRCUIT ADJACENT TO X-RAY UNIT OR IN HALL. SEE .SHEET SE.1 FOR LOCATION, SEE HENRY SCHEIN PANEL CUTOUT NOTE OWER REP FOR EXACT HEIGHT. LOW -VOLTAGE & WER CABINET (SEE CABINET DRAWINGS FOR ACTUAL CABINET LAYOUT) AUTOCLAVE OUTLET SEPARATE CIRCUIT 20 AMP HEIGHTS TO BE DETERMINED 0- AUTOCLAVE PROVIDED AND INSTALLED BY HENRY SCHEIN DENTAL STATIM, OUTLET SEPARATE 15 AMP CIRCUIT HENRY SCHEIN DENTAL EQUIPMENT SPECIALIST TO DETERMINE LOCATION. NOTE* SWITCHED OUTLET RECOMMENDED. --�STATIM PROVIDED AND INSTALLED 1 'no BY HENRY SCHEIN DENTAL CONDENSER BOTTLE OUTLETS PROVIDED AND INSTALLED BY CONTRACTOR AUTOCLAVE AND STATIM OUTLET. NOT TO SCALE MODEL 1025D 5 TOTAL HP 1.5 VOLTAGE 230 BREAKER$Zi 20A HERTZ 610 AMPS 8.4 TANKSIZE 10 GAL. WIDTH 24-3U' DEPTH 20,$-271, 1 HEIGHT 2615 30" IWEIGHT 174LBS NOTES. 1. SUPPLY HOSE, 1/4'mtpx3/6'mtp, &LONG (SUPPLIED) 2. DRAIN TUBING, 3/9'PLASTIC, 4' LONG (SUPPLIED) 3. BUSHING, I]Tmpt x 3/Vlfpt (SUPPLIED) 4. ALLOW 6" S . ERVICE CLEARANCE ON SIDES., BACK AND TOP OF COMPRESSOR. MAINTAIN I Z'CLEARANCE IN FRONT OF COMPRESSOR. CONNECT FRESH AIR INTAKE (USES V HOSE BARB) TO EXTERNAL AIR SOURCE PER NFPA 99C RECOMMENDATIONS. CONNECT UNIT TO OUTLET ON 230V, 20A DEDICATED CIRCUIT. LOW -VOLTAGE CONTROL WIRING TERMINALS. MAX. DISTANCE FOR 18 GA. WIRE-- 500 FT, CONNECT UNIT TO FACILITY PLUMBING USING PROVIDED SUPPLY HOSE. USE BUSHING IF NECESSARY. NOTE: INSTALL UNIT PER. FOLLOWING ALL LOCAL & STATE CODES. RMC1025D IRCAOMPRESSOR j NOT TO SCALE MAY REQUIRE SEPARATE JUNCTION BOXES. VERIFY LOCAL CODE REQUIREMENTS. di uj LOW -VOLTAGE WIRE TO X-RAY > UNIT (SPEC. 9) SEE MANUFACTURER'S INSTALLATION MANUAL FOR MORE DETAIL, BEL 096 X—RAY CONTROL BOX NOT TO SCALE DOUBLE BOWL SINK (MAY VARY TO SINGLE BOWL) RECESSED ULTRASONIC CLEANER REMOTE TIMER PANEL ULTRASONIC CLEANER DRAIN ULTRASONIC CLEANER GENERATOR ADJUSTABLE SHELF 1 ULTRASONIC CLEANER. NOT TO SCALE ODEL QT- 1,2 VERIFY AMBIENT ROOM DISCONNECT )TAL HP 1.0 ---9-5/-230 TEMPERATURE AND D.LTAGE VENTILATION REQUIREMENTS DEDICATED 'EAKER SZ, 20A WITH MANUFACTURE CIRCUIT RTZ mps 13.4/6,7 PRE -INSTALLATION GUIDE 7 BUILDING IDTH 25' POWER =PTH SUPPLY PANEL TO OPTIONAL REMOTE CONT ZOL PANEL Q EXHAUST TO ELECTROL OUTSIDE BUILDING (SUPPLIED BY RAMVAC) (Z'SCH. 80 PVC OR METAL) JUNCTION BOX (OPTIONAL) 0 15 GAL. OTTER TANK TREATMENT ROOM DRAIN LINE (TO SEE DETAIL(S) 1,3 OR 3A FOR VACUUM FLOOR DRAIN LINE STUB -UP REQUIREMENTS WITHIN . OR P-TRAP) -I 1 /2' ROOM. PV PI C FLOOR PE --------- - - TR TANK LINE- 1 1/2'OR 2" PVC W/ DWV VACUUM LINES PER LOCAL CODE, FITTINGS OR COPPER PER LOCAL CODE SLOPE MINIMUM I/4PPER 10 FEET. WOTEW' REFER TO RAMVAC SPECS AND PRE -INSTALLATION GUIDE FOR EXACT REQUIREMENTS. VERIFY LOCAL CODES BEFORE INSTALLING UNIT, \BULLDOG COMBO 1 &2 NOT TO SCALE ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR FOLLOWING ALL LOCAL CODES FOR ROUGH INSTALLATION. HENRY SCHEIN TO MAKE FINAL CONNECTIONS. ELECTRICIAN TO PROVIDE A FLUSH -MOUNTED SINGLE GANG JUNCTION BOX & 3/4!'CONDUIT W/ PULL -WIRE BETWEEN EXPOSURE BUTTON & X-RAY MASTER CONTROL/UNIT.—���� X -RAY EXPOSURE BUTTON f".)— VERIFY WIRING REQUIREMENTS BETWEEN EXPOSURE BUTTON AND X-RAY MASTER CONTROL/UNIT WITH MANUFACTURER'S INSTALLATION MANUAL. PROVIDED BY HENRY-SCHEIN DENTAL, INSTALLED BY ELECTRICIAN. SEE MANUFACTURER'S INSTALLATION MANUAL FOR MORE DETAIL. X—RAY EXPOSURE BUTTON NOT TO SCALE COLD WATER, PLUMBER.'SHALL PROVIDE AND INSTALL A CHROME PLATED ANGLE STOP (VALVE) TO BE LOCATED AT MODEL TRIMMER MODEL TRIMMER - 115V. 15AMP. ELEC. OUTLET FOR MODEL TRIMMER., DRAIN HOSE FROM MODEL TRIMMER TO EXPEL INTO SINK. DRAIN HOSE --- me FRONT VIEW MODEL TRIMM NOTTO.SCALE 314- UNION (2 P' PROVIDED BY PI I I 5V WALL OUT WITHIN 5'OF Wi FILTER BYPASS, LOW VOLTAGE CONTROL WIRE STANDARD LAB SINK SUPPLIED AND INSTALLED BY PLUMBER FLEX.HOSE (SUPPLIED) 0 SINK DRAIN 0 PLASTER TRAP & HOSES PROVIDED BY HENRY SCHEIN DENTAL AND INSTALLED BY PLUMBER. BASE OF SINK CABINET SIDEVIEW DISP. PLASTER TRAP NOTE: WHEN MOUNTING FROM ABOVE OUTLET STATION. VACUUM PIPING FOR GAS SCAVENGING MUST INCLUDE VERTICAL LOOP TO PREVENT BACKFLOW OF LIQUIDS INTO VACUUM BLOCK. 1/2" 01). VACUUM LINE 1/7'O.D. OXYGEN FROM TANK ROOM 3/8" O.D. NITROUS FROM TANK Room WALL FRAMING------_., BRACKET "A" TO MOUNT TO STUD BEFORE GYP. BIRD - --------- PROVIDED BY HENRY SCHEIN DENTAL AND INSTALLED BY PLUMBER THIS DRAWING REPRESENTS A TYPICAL INSTALLATION AND IS FOR INFORMATIONAL PURPOSES ONLY. REVIEW MANUFACTURER SPECIFICATIONS FOR EXACT MODEL AND SYSTEM REQUIREMENTS. N20,02AND VACUUM OUTLET STATION NOT TO SCALE SEE ACTUAL VALVE TO ADJUST THE MOUNTING POSITION OF THE 1, 2„ FPT ADAPTOR SO THE. TRIM RING IS SECURED FIRMLY AGAINST THE S.HEETROCK. AIR VALVE PROVIDED AND INSTALLED BY CONTRACTOR, 3/9'COMPRESSION FITTING OR OPTIONAL FEMALE QUICK DISCONNECT PROVIDED & INSTALLED BY CONTRACTOR. AIR VALVE NOT TO SCALE I ITSUP x I /Z'FPT ADAPTOR. PROVIDED & INSTALLED BY CONTRACTOR, 1/2" FEMALE ADAPTOR PROVIDED & INSTALLED BY QNTRACTOR. AIR LINE BY CONTRACTC Q- ®R ANCHOR TERMINATION FITTINGS SECURELY TO A OR A CROSS BRACE. FITTINGS PROVIDED AND INSTALLED BY CONTRAC VACUUM WALL OUTLET NOT TO SCALE LOW VOLTAGE CONTROL WIRES - RUN 18/3 BELL WIRE FROM UNITS TO MASTER CONTROL PANEL (CONTRACTOR TO SUPPLY WIRE) STUB PIPE OUT OF STANDARD SINGLE GANG BOX (2-1/8" D x WALL 6" 4!'H x 7'W) SUPPLIED BY ELECTRICIAN MASTER WATER SHUT—OFF W/FILTER NOT TO SCALE 1 /7'PVC SLIP X SLIP, 900 ELBOW. PROVIDED �& INSTALLED: BY CONTRACTOR. ANCHOR TERMINATION FITTINGS SECURELY TO A STUD OR A CROSS BRACE, FITTINGS PROVIDED AND INSTALLED BY CONTRACTOR. I /Z'SC-H 40 PVC BRANCH FROM MAIN TRUNK LINE. PROVIDED & INSTALLED BY CONTRACTOR. 60" THIS IS A TYPICAL INSTALLATION. SEE A.F.F. MAN U FACTURER'S SPECS FOR EXACT EQUIPMENT REQUIREMENTS. , n RA M�V �ACCONTROL PANEL NOT TO SCALE ISSUE DATE REAM 02/22AI PERMIT 02/23/11 REV. REV. REV. IREV. 7tME POUMM VM05 NOTE5 MTAiL5 NO 935CMAWM AND CONCEPTS ARE IM SOLE MMM OF MAZE MM M AND SHALL NOT BE N"==, M-USED OR GOP® FOR Mat PROJMI% IN MOLE OR FM MW 7W W7N CONSENT Of MW FRAM ARGHr=T, AIA6 ALL ROM AM IMURVW BY THE ARCHITECT IN ACCORDANCE NTH UA COMIOW AND FATEW LAWS. WAmimm REPRO zTm YcL BE Mwwfxw To THE FULL EXTENT OF THE LW O V) w W /-� ;4 0 4-4 con 4-a U 1.4 0 u OfM-9910NAL 5C6L 1,.EO Glta s ..C) 0 ®° 0 00 uj ZP gap I A SHEET TITLE M.UMIDING DETAILS THESE RECOMMENDATIONS ARE BASED: ON NFPA-99 STANDARDS FOR MEDICAL GAS SYSTEMS. LOCAL BUILDING AND FIRE CODES MAY SUPERSEDE NFPA-99. IMPORTANT: VERIFY LOCAL REQUIREMENTS BEFORE BEGINNING CONSTRUCTION. SIGNAGE REQUIRED ON DOOR - CAUTION .MEDICAL GASES NO SMOKING OR OPEN FLAME ROOM MAY HAVE INSUFFICIENT OXYGEN OPEN DOOR AND ALLOW ROOM TO VENTILATE BEFORE ENTERING PIPING (SEE MFR. SPECS) LOW VOLTAGE: CONTROL I HR. FIRE RATED WIRES: TO D-34 ROOM MANIFOLD INSTALLED BY 1 HR. FIRE RATED CONTRACTOR DOOR WITH LOCK ,--CYLINDER CAPTOR INSTALLED BY CONTRACTOR, ---CYLINDERS BY DOCTOR N20, 02 C t NOT TO SCALE REQUIRES VENTING TO BUILDING EXTERIOR PER NFPA-99 STANDARDS PROVIDED BY HENRY SCHEIN DENTALAND INSTALLED BY CONTRACTOR LINDER CLOS T 4 CYLINDERS LOW VOLTAGE WIRE TO MANIFOLD SYSTEM WIRE BY HENRY SCHEIN DENTAL TO A I I 5V OUTLET IN CEILING SPACE 1.5 A CUTOUT DIMENSIONS MOUNTING FRAME PROVIDED BY HENRY SCHEIN DENTAL AND INSTALLED BY CONTRACTOR. N2, 2 ALAR1 PANEL NOT TO SCALE 115 VAC RECEPTACLE VtATSrREMMFT5 IN' CYLINDER ROOM (PERMITTED IN LEVEL 11 FACILITY) LATOR (TYP.) TO OUTLETS (IF ZONE VALVES ARE NOT REQUIRED) O.D. i'O.D. 02 SYSTEA �o 0 MANIF N20 N20 02 2 X 10 BLOCKING FLUSH WITH STUDS, 4U'A.F.F. TO CENTER LINE. - NOT TO SCALE -THE ELECTRICIAN SHALL EXTEND L/V CABLE, PROVIDED WITH THE EQUIPMENT, FROM THE MANIFOLD TO THE ZONE VALVE, (IF REQUIRED.). CYLINDER ROOM LEVEL I I I FACILITY WITH LESS THAN 2000 CU. Fr. GAS (INCLUDING STORAGE, EXCLUDING NITROGEN). 99 i- O.D. 02 - k'O.D. N20 CYLINDER RESTRAINTS FROM MANIFOLD THE ELECTRICIAN SHALL EXTEND L /V CABLE, PROVIDED WITH THE EQUIPMENT FROM THE MANIFOLD TO THE ALARM STATION. MANUAL ZONE VALVES _'N (VERIFY THAT ZONE VALVES ARE TO BE USED,) REQUIRED WHEN THE CYLINDERS ARE REMOTELY LOCATED OR SERVICE MORE THAN ONE FACILITY. VERIFY GAS DIRECTION. TO A` O.D. N20 OUTLETS �'O, D. 02 -CAI I =2016 115 VAC SERVICE MAY BE REQUIRED FOR THE ALARM STATION (VERIFY), ALARM. STATION WALL MODEL IS ILLUSTRATED A DESK MODEL 15 OPTIONAL (REQUIRED BY NFPA 99). Z:3-la . = cr 758" A.F.F. GENERAL REQUIREMENTS 1.),STRICT ACCORDANCE WITH THE NFPA 991 IS REQUIRED. 2.1 IF THE CYLINDER ROOM IS REMOTELY LOCATED IT MUST BE LOCKED. 3.) THE CYLINDER ROOM SHALL BE VENTILATED WITH NO LESS THAN 72 SQ IN TOTAL FREE AREA WHEN NO OTHER VENTING IS POSSIBLE. 4.) USE TYPE K OR L PRE CLEANED, DEGREASED, CAPPED COPPER PIPING ONLY. 3/-W'O.D, FOR N20 AND 1/2"FOR 02. 5.) USE SILVER SOLDER OR SIMILAR BRAZING ALLOY. SOLDER SHALL HAVE A MELTING TEMPERATURE Of 1000 DEGREES F. 6.) PRIOR TO SHEET ROCK, STATIC PRESSURE TEST THE PIPING SYSTEM USING DRY ,NITROGEN AT 150 PS.L FOR 24 HOURS. 7.) EACH LINE SHALL BE INDIVIDUALLY TESTED TO ENSURE THE PIPING DID NOT GET CROSSED. CONNECT THE N20 / 02 CYLINDERS AND SET THE PRESSURE ACCORDING TO INSTRUCTIONS. CHECK ONLY ONE GAS AT A TIME. 8.) LABELING SHALL APPEAR ON THE PIPING AT 20 FT, (MAX) INTERVALS AND AT LEAST ONCE IN EACH TREATMENT ROOM. 9.) THIS ILLUSTRATION IS FOR THE GENERAL LAYOUT ONLY. EXACT EQUIPMENT REQUIREMENTS SHALL BE AS DIRECTED AT SITE. 10.) PROVIDE A I HOUR FIRE -RATED DO a' O.D. N20 I'O.D. 02 SEE MAN UFACTURER'SS.PECS FOR INSTALLATION � 1,4 —IL , Nj-,� r —,%LLC_ l' Rpfl_'lL"4 fOS t_0tA-rL_&A OUTLET STATION RECESSED MODEL �2 ILLUSTRATED. Lu z 'm 0 REDUCE TO VACUUM ,00 OUTLET (IF REQ'D) Lu VACUUM TRUNK LINE 0 (IF REQ'D) FINISHED FLOOR ISSUE DATE REVIEW 02/22/11 PERMIT 02123AI REV. REV. REV. Rr=v. 1r M VOUM4% MIM, trans, LeTAILS NO sPECIFIGATM MV WWLTIS ARE THE SOLE PROPHiT I M FRAZE VMRK NO. AV %OU NOT BE lar ==, PM42M OR COPIED FOR OTHM MX507% IN WOLE OR FMr MMM 7w HRMM WOW OF FRANC FRAZE, ARCHIMT, ALA. ALL M&M ARE FM5MVW Vf TW ARCHITECT N ACWWANCE NTH UA C*vtRr*ff AND WENT LAN5. MOONED IROMROMTON NLL DE MaMW TO IM MI MW OF M LAK O 11 Tv W�QQ O �4 U���N PRD_fr:55I0NAL SEAL 40, : O� bo Ic E SHEET Tl= PLUMSINCHDETAILS yr s 0 a �1 J C, Q . LIFE SAFETY PLAN SCALE: 1/4" = I' —On EXIT REQUIREMENTS: MAXIMUM TRAVEL DISTANCE TO EXIT - 300'-0" FROM ANY POINT. SQUARE FOOTA6E CALCULATIONS: SQUARE FOOTAGE UNDER IMPROVEMENT 2552 50 FT NUMBER EXITS: TOTAL SQUARE FOOTAGE OF SPACE 2552 S.F. DIVIDED BY NEB`/50. FT PER OCCUPANCY IOO 24 TOTAL NUMBER OF PEOPLE ON FLOOR. NUMBER OF DOORS PROVIDED 2 NUMBER OF DOORS REQUIRED: 2 ALL WOa'CWMABUI �II3G pnVABMG CODES,CCODEASND GOD ,,NpaoNALAECM CITY OT &WflMls REVIEW DATE CITY OF ZEPHYRHILL� PLANS EXAMINER ISSUE DATE REVIEW 02/22/11 PERMIT 02/23/11 REV A 05122A I REV REV. REV. 9Pv gcAim my coNf.E nS ARE IM SOLE PRO"" OF MAM DsI911, wG. ANv SKL Nor w I"RODuoED RrAM OR c pw POR ordm FAMCM w fi1OLE OR PART NI1 M IM HWM cO eW OF MWK PRAM ARG111Ef6T, AM ALL 140M AM IMERM Wr IM AR HOW IN ACCORDANCE NO UA cOPYRIBMr AW PAlW L 4& UMhOM= REDUCTION HU W PP4Wa= W TIE Ku E cmw OF TIf LAK S N 0 z a cn w� A za� 114 Wawao A t wa U VQ�N ORA FRAWLIN r � MEN• MEN• • • • 1�1 it � f• s F W STANDARD FOR FORTABLE FIRE EXTINGAISHERS ALL FIRE ti s r MST BE CERI-.ar syFIRE 3. . •.- IIIALLS 14AVE I METAL 87W OR FACE r.�• ZIP ADDRESS To BE LOCATED OF INTERIOR MOCK. IIIALLS Rl �� ♦ -� Mir I • - r , i . ON FMA- OF r♦♦-4. . COORDINATED11ENSM AND ELEVATIONS, Zil -1 [OVATION NOTES: $0110 ® ��� I \ i \x / TRIC IN P400M WALL ♦ -_ / -`.. IMm`-BE yr. 1' I . PROOF ♦-_IPER MECHANICAL ROOM TO - NOT BE M FOR STORAGE OF ANY KIND. IT ALSO SHALL BE SMOKE TIGHT AND ABIDE BY Ill POI, 6.112 r--1 EXISTING �--rRESTAURANT T HW A4 WALL - EXISTING ONE HR RATED - DEMISING WALL TO 104NN 0 '+ 4'-0' ah. HT. 115 Y1• - 1 -- ME II 11 I I STF�ILIZATION I I I 110 + Tl CL.6. HT. i II II -- MNISTRA71ON + 4'-0' CI-6. HT. 0 N 116 A I I I I I I I I 1� if i I WAFTING loo + q,-ol CL6. HT. EXISTING ONE HR RATED DEMISING WALL TO REMAIN ■l�� l 17t�,'i!"1 a. a. 4 Q 4 A zss BOX FOR FIRE DEPARTMENT UPON CONIF' MON OF CONSTRUCTION 4 4 6REAT EXPF4 56M WILL PROVIDE Q d A& RENOVATION PLAN SCALE, 1/411 = 1'-011 - EXISTWN6 RESTAURANT 2. ALL DEMOLITION UIORK SHALL BE FERFOR W W1H "DUE CARE AND DILKTICE' SO AS TO PREV9dT THE ARBITRARY DESTRUCTION OF INTERRIPTION OF CONCEALED UTILITIES VACH ARE INTWW TO RBUIN IN USE AND TEE ROUTING OF UACH COULD NOT BE FIRE-DETERMIIIIED WiIL DE11OLItION WAS STARTED. ALL SUCH DISCOAM OF UTTLITIES DURM THE DLaN01-ITION PROCESS Ill ARE N A LOCATION DIIFFERENT FROM THAT INDICATED, CHANGE DIRECTION, ETC. OR ARE WDWFW, WALL BE REPORTED TO TEE ARCHITECT J OWNER 9WORE REINOYAL FOR FINAL. DEPOSITION. I REMOVE ALL CONSTRUCTION DESKiNATED TO BE REIWO D AND CLEAR TO RECEW NEW WOW AS HERE -IN NDIOATED. 4. RBWVE PORTIONS OF EXISTING CONSTRUCTION AS DRAW AND PATCH TO MATCH AWACENT CONSTRUCTION TO ACIHEVB UNIFORM, NEW APFEARANCE S. THE OUHER WILL NOT BE NMI) LIABLE FOR FIELD C"GES THAT ARISE FROM CONTRACTOR ERROR OR OMISSION OF MATERIALS. 6. TEE CONTRACTOR GIAR4NTEES ALL WOW AGAINST FAULTY OR MPBRFECT MATERIALS OR WORMANSHIP ALL WORK SHALL BE ENTIRELY UWTERTIGHT AND LEAKPROOF. ALL MATERIALS ARE INSTALLED IN ACCORDANCE WITH MANFACTURER'S RECOM MI90ATIONS -I. TEE CONTRACTOR SHALL GIVE UI211TEN NOTICE TO TEE ARCHITECT OF ANY MATERIALS, EQ11MENT OR DESKN FEATURES U #CH 1 E BEI-EVES NADEaAATE OR UNSUITABLE* N VIOLATION OF LAWS, ORDINANCES, OR RILES AND REGULATIONS OF ALL AUTHORITIES HAVING JURISDICTION OVER: THE WORK4 AND OF ANY NECESSARY M" OR WORK OMITTED FROM THE DRAWINGS OR SPECIFICATIONS 8� PLANS W� DEVELOPED FROM INFORMATION SUhfiLED BY THE OVER AND EXISTING CONDITIONS 0860;ZVED. ANY DISCRB'ANCES BETUM DR IIIINGS AND EXISTING CONDITIONS ARE TO BE REPORTED TO ARCHITECT PRIOR TO STARING WOW ON A GIVEN ITEM AI D BOORS INCUR" ANY ADDITIONAL COSTS 3 CONTRACTOR SHALL FIELD VERIFY ALL DHENSIONS, INDICATED. FABRICATION SHALL BE BASED ON THE ACTUAL FIELD MIENS!" ONLY. 10. ARCHITECT HAS NOT CONDUM ANY NVESTIGATION AS TO THE PRESENCE OF ASBESTOS OR ANY OTHER HAZARDOUS SUBSTANCE AND A86M NO RES oamiLTTY WITH RESPECT TO SAME. U. DEWAN DRAWMS INDICATE SC14EM4TTC STRUCTURAL M B 10ER LAYOUT. CONTRACTOR SHALL SUBMIT SWOP DR4WAM INDICATING ACTUAL LAYOUT OF ALL S'UCTURAL FOR APPROVAL. PRIOR TO NSTALI ATICN, ALONG WTH REGISTERED STRUCTURAL 'S CALCULATIONS ALL MBA SHALL. BE INSTALLED ACCORDING TO MANIFACTIIFIERS RECatlIENDATIONS INCLUDING BRACING, SPACING, ETC, 12. CONTRACTOR PRIOR TO INSTALLATION WALL. FEW VERIFY ALL EXISTING CONDITIONS AND BRING TO THE ATTENTION OF THE ARCHITECT ANY DISCREPANCIES 13 CONTRACTOR 16 WIAESTED TO VISIT TEE SIZE. COWARE TEE DR4IUNGS AND SPECIFICATIONS WITH VISIBLE EXISTINS CONDITIONS AND WORM ARCHITECT AS TO ANY DISCREPANCIES PRIOR TO BD SUE MISSION SO AN ADDENDA" I CAN BE ISStl FAILURE TO VISIT TEE SITE WLL IN NO WAY MCA THE CONTRACTOR FROM NECESSITY OF FURNIS" ANY MATERIALS OR ANY WORK THAT MAY BE REGILMIED TO COMPLETE WORK IN ACCORDANCE UATEI DRAWINGS AND SPECIFICATIONS WITHOUT ADDITIONAL COSTS TO TEE OWNER 14.1W CONTRACTOR SHALL BE RESPONSIBLE FOR TEE EQLIFhENT AND METHODS USED N TEE ERECTION OF HIS WOIRIC COVERED BY TEE CONTRACT, BUT TEE ARCHITECT RESERVES TEE WGHT TO APPROVE SUCH EQUUiPI W AND METHODS 5 THE C ,111RACtOR SHALL BE TOTALLY RESPONSIBLE FOR ANY AND ALL DEVIATIONS FROM THE CONSTRUCTION DRAWINGS INSTALLED WTI40UT APPROVAL OF ARCHITECT AND LOCAL JURISDICTION. TEES INCLUDES REPAIR COSTS NECESSARY TO CORRECT WAPPROVED UJOWc NSTALLED. RENOVATION LEGEND: INDIGAn5 N EN Ill INDIGATi'-a EXI5TIN6 WALL *as DATE REVIEW 02/22AI PERMIT 02123AI REV. 1 05/22/11 REV. REV. REV. SPWAlIGAt10NB AND l AM 1W SM rRO my OF fiRAM VW K W. AND qvu NOT a IiEPRdD m, RBw OR copes fm am PRO l M N M= OR PART 1itNW 7Ne NRIi M COMW OF PRANG MtM WNW, Al ALL Wft ARE RE°�WW BY M i4RAMW N AGG K"NM WITH VA GOPT Off AIV PAM LArlb. WMaRm fe"Awto" mu eePrWa6cm To tNe �u extair of the LArt ORA FRANKLIN ~ Mt` N � � N 4 o � w W W as to 000 N N w 0 w 0 ® M N all bw� <` w aOo a 1 GENERAL NOTE: MOUNTING HEIGHT OF...ALL.__R.ECE.PTACLES_, SWITCHES.,_ AND DEVICES IS TO BE AS INDICATED ON DENTAL EQUIPMENT SUPPLY DRAWINGS. VERIFY ALL MOUNTING HEIGHTS' WITH DENTAL SUPPLIER IN WRITING PRIOR TO ROUGH -IN. Ai B-19 l .............................................. A-6 A-4 A-2 ELECTRICAL LEGEND Q GENERAL NOTE: 0 . __. _ _ _ - _ RE USE 2 EXISTING 200A METERS __.. ,.. _. ........ MOUNTING ,,HEIGHT OF ALL __ H ....... - _ --- R CEPTACLES SWITCHES E __ --- _. .... _._. ._...... .---------..... ...... -::: SERVICE DISCONNECTS AND DEVICES IS TO BE AS INDICATED ON DENTAL HOME RUN TO PANEL NOTE: ALL DEVICES & EQUIPMENT EQUIPMENT SUPPLY DRAWINGS. VERIFY ALL MOUNTING NOTE: ALL DEVICES & EQUIPMENT IN THIS TO BE EXPLOSION HEIGHTS WITH DENTAL SUPPLIER IN WRITING PRIOR IN THIS ROOM TO, BE EXPLOSION >@r DUPLEX RECEPTACLE, 18" A.F.F., GFCI IF SHOWN ON PLAN -ROOM PROOF AND SHALL COMPLY WITH TO ROUGH -IN. PROOF AND SHALL COMPLY WITH DUPLEX RECEPTACLE, 42" A.F.F., GFCI IF SHOWN ON PLAN NEC 517.60A NEC 5:.1:::7.60A cFcl ®C CEILING MOUNTED DUPLEX RECEPTACLE 0 `FY FLOOR MOUNTED DUPLEX RECEPTACLE AND COMBINATION _..,. ' _.. _. VOICE/DATA OUTLET _. B— -21 ®�® . „ QUADRUPLEX RECEPTACLE, OR AS NOTED OUTLET, COMBINATION VOICE/DATA 8"A.F.F. OR AS NOTE +rFa -B 2 a DISCONNECT SWITCH .......JUNCTION BOX :. _. t MOTOR, NUMBER INDICATES HORSEPOWER R, MB ' FGFCI -- , � 42" A.F.F._ _ .F.F. 3 3 DIM MOTION SWITCH, - WAY; D MER; M ; CALETTERS a, b ETC INDICATE FIXTURES CONTROLLED cFet ° ;..... , . :. ... '.. _. 200A.,: PA1vEL A & B FEEDERS: ................ ;' . 0 120 1 60 WITH BATTERY BACKUP SMOKE DETECTOR, / / >: B_4 .� 2x 4OQQ ICU, 1 #4 CU 0; 2 C ¢ ;.. Q ¢ 11 _ • :..... DETECTOR, 12 60 WITH BATTERY BACK UP 165 HEAT DETE , _. O TV CONNECTION PNL "A" PNL "B' �....: _. B 14 - TIMECLO C K -14 WTR HTIR g-1 p B- 4 1x4 FLUORESCENT LIGHT FIXTURE, LETTER INDICATES TYPE A-10 A-21,23. 10 - .;..Q c....:.. A X A A 2x4 FLUORESCENT LIGHT FIXTURE, LETTER INDICATES TYPE B-18 _ X 0 FLUORESCENT STRIP FIXTURE, LETTER INDICATES TYPE 17 : -10 8 I:D g.-13 Qo A RECESSED CAN LIGHT FIXTURE, LETTER INDICATES TYPE g'25 FG"t;; -- o OC2 RECESSED WALLWASH FIXTURE, LETTER INDICATES TYPE CEILING LIGHT FIXTURE,LETTER INDICATES TYPE _ RTU-.4T. a WALL MOUNTED LIGHT FIXTURE, LETTER INDICATES TYPE cFct. .:: _... WA MOUNTED EXIT EMERGENCY LIGHT W BATTERY ... _ m LIGHTED EXIT SIGN WITH BATTERY BACKUP �- 1 OR 2 WAY AND DIRECTIONAL INDICATORS AS SHOWN <7 B 23F - B 10 - 10 i ,--. NOTE: NOT ALL SYMBOLS ARE USED IN THIS PROJECT. SEE PLANS. B 15 .... .. .............. . ..................... ........ Rl GENERAL NOTE:- - INSTALLATION OF ALL ELECTRICAL SHALL FULLY COMPLY WITH ALL APPLICABLE SECTIONS OF NEC 517, IN PARTICULAR SECTION IV - "INHALATION ANESTHETIZING LOCATIONS". ELECTRICAL POWER PLAN E-1 SCALE: 1/4" = V-0" NORTH m 4 RISER NOTES: (D 1. EXISTING UTILITY SERVICE ON REAR EXTERIOR L , (2) EXISTING 200A METERS AND SERVICE DISCONNECTS. COORDINATE MULTI -METERING OF THIS TENANT SPACE WITH UTILITY. CLEARLY LABEL METERS/DISCONNECTS WITH SPACE NAME AND ADDRESS PER AHJ. 2 PROVI EW 200A 20836 F DE 0 C DUIT AS NECESSARY TO EXISTING STUBS FROM METER BANK. FEEDERS EACH: 4 #000 CU, 1 #4 CU G, 2"C 3. NEW 200A PANEL "A" AND "B" ON WALL IN BREAK ROOM. SEE PANEL SCHEDULE FOR MORE INFORMATION. 11;0i1919 ELECTRICAL RISER DIAGRAM SCALE: NONE DCH PROJECT NUMBER: 11-002 0 TO THE BEST OF THE KNOWLEDGE OF THE ARCHITECTS AND ENGINEERS, SAID PLANS AND SPECIFICATIONS COMPLY WITH THE 2007 FLORIDA BUILDING CODE WITH 2O09 SUPPLEMENTS AND THE APPLICABLE MINIMUM FIRE SAFETY STANDARDS. ALL DIMENSIONS AND JOB CONDITIONS SHALL BE VERIFIED BY THE CONTRACTOR, ANY AND ALL DISCREPANCIES SHALL BE REPORTED TO THE ARCHITECT PRIOR TO COMMENCEMENT OF CONSTRUCTION. THE DRAWINGS & DESIGN ARE VALID FOR 12 MONTHS FROM DATE OF ORIGINAL SEAL. m ¢ z Q Q Lv N LL Y z LL I U Z Z C� LLJ 0 LLJ N ¢ 0 N 2 r 0- CD ISSUE DATE REVIEW 1 /27/11 PERMIT 1 /27/11 REV. 0 3/10/11 REV. REV. REV. THESE DOCUMENTS, DESIGNS, NOTES, DETAILS AND SPECIFICATIONS AND CONCEPTS ARE THE SOLE PROPERTY OF FR AZE DESIGN INC. AND SHALL NOT BE REPRODUCED RE -USED OR COPIED FOR OTHER PROJECTS, IN WHOLE OR PART WITHOUT THE WRITTEN CONSENT OF FRANK FRAZE, ARCHITECT, AIA. ALL RIGHTS ARE RESERVED BY THE ARCHITECT IN ACCORDANCE WITH U.S. COPYRIGHT AND PATENT LAWS. UNAUTHORIZED REPRODUCTION WILL BE PROSECUTED TO THE FULL EXTENT OF THE LAW. PROFESSIONAL SEAL ee ldllddl,0 a '� �G . IN �S� •" N , 5 4lo 09 `® • o er E OF s 1 ® O.R®� O ®®at�p VI FLoif . �( 9 � m z A N r U a0o � RJ � A 0 W W a o � M 00 N M N w W W > 0 00 ai 00 m w � U o� w � w SHEET TITLE ELECTRICAL PLANS SHEET NUMBER ;:�) MECHANICAL PLAN M-1 J SCALE: 1 /4" = 1'—O" NORTH KEYED NOTES: (D 1. EXISTING PACKAGED ROOFTOP UNIT WITH ELECTRIC HEAT TO REMAIN. CLEAN/SERVICE/REPAIR UNIT AS NECESSARY TO LIKE NEW CONDITION. RE —CONNECT NEW DUCTWORK AS SHOWN ON PLAN. CONNECT EXISING SUPPLY AIR SMOKE DETECTOR FOR AUTOMATIC UNIT SHUTDOWN AND CONNECT TO BUILDING FIRE ALARM (IF APPLICABLE). RE —BALANCE AIR FLOWS TO VALUES AS FOLLOWS: A) EXISTING 5 TON UNIT: SUPPLY AIR: 1,650 CFM RETURN AIR: 1,330 CFM OUTSIDE AIR: 320 CFM B) EXISTING 4 TON UNIT: SUPPLY AIR: 1,250 CFM RETURN AIR: 970 CFM OUTSIDE AIR: 280 CFM 2. PROVIDE NEW BATHROOM EXHAUST FAN AND 6"0 METAL EXHAUST DUCT TO ROOF CAP. CONNECT FAN TO ROOM LIGHT SWITCH FOR SIMULTANEOUS OPERATION. 3. PROVIDE NEW DIGITAL 7—DAY TEMPERATURE CONTROLLER ON WALL WITH LOCKING CLEAR PLASTIC COVER. MOUNT CONTROLLER MAX. 48" A.F.F. 4. PROVIDE 18x6 LOUVER LOW IN DOOR FOR RETURN AIR FROM THIS ROOM. COORDINATE EXACT STYLE, FINISH, AND PLACEMENT WITH ARCH. 5. PROVIDE NEW GENERAL EXHAUST FAN AND 6"0 METAL EXHAUST DUCT TO ROOF CAP. CONNECT FAN TO SEPARATE WALL SWITCH FOR OPERATION AS NEEDED. 6. PROVIDE NEW EXHAUST FAN WITH EXPLOSION PROOF MOTOR AND 6" 0 METAL EXHAUST DUCT TO ROOF CAP FOR GAS STORAGE ROOM. FAN SHALL RUN 7. GAS STORAGE ROOM VENTILATION LOUVERS (2). MINIMUM 72 SQUARE INCHES FREE AREA EACH. INSTALL ONE LOUVER WITHIN 12 INCHES OF FLOOR AND OTHER LOUVER WITHIN 12 INCHES OF CEILING. COORDINATE EXACT LOCATION, STYLE, AND 0 FINISH WITH ARCH. & OWNER PRIOR _TO CONSTRUCTION. w w MECHANICAL LEGEND AXB, AO SUPPLY AIR DUCT, DIMENSION "A" SHOWN AxB, AO RETURN AIR DUCT, DIMENSION "A" SHOWN FLEXIBLE DUCTWORK, SAME SIZE AS DIFFUSER NECK —� REFRIGERANT PIPING �Z�I�17�►C.`Lrl���l:7_11�«'�R7► e FZJ ® SUPPLY AIR DIFFUSERS RETURN AIR GRILLE ® EXHAUST AIR GRILLE _)P- FIRE DAMPER �Vo VOLUME DAMPER m THERMOSTAT, 48" A.F.F. ROOFTOP EXHAUST FAN ® CEILING EXHAUST FAN HVAC EQUIPMENT TAG CU —DENOTES EQUIPMENT TYPE 1 —DENOTES EQUIPMENT NUMBER AIR DEVICE TAG --DENOTES DEVICE TYPE MRG-1 6 DENOTES NECK/FLEX DUCT SIZE 60 --DENOTES AIR FLOW (CFM) DCH PROJECT NUMBER: 11-002 TO THE BEST OF THE KNOWLEDGE OF THE ARCHITECTS AND ENGINEERS, SAID PLANS AND SPECIFICATIONS COMPLY WITH THE 2007 FLORIDA BUILDING CODE WITH 2O09 SUPPLEMENTS AND THE APPLICABLE MINIMUM FIRE SAFETY STANDARDS. ALL DIMENSIONS AND JOB CONDITIONS SHALL BE VERIFIED BY THE CONTRACTOR, ANY AND ALL DISCREPANCIES SHALL BE REPORTED TO THE ARCHITECT PRIOR TO COMMENCEMENT OF CONSTRUCTION. THE DRAWINGS & DESIGN ARE VALID FOR 12 MONTHS FROM DATE OF ORIGINAL SEAL. ISSUE DATE REVIEW 1 /27/11 PERMIT 1 /27/11 REV. QT 3/10/11 REV. REV. REV. THESE DOCUMENTS, DESIGNS, NOTES, DETAILS AND SPECIFICATIONS AND CONCEPTS ARE THE SOLE PROPERTY OF FRAZE DESIGN, INC. AND SHALL NOT BE REPRODUCED, RE -USED OR COPIED FOR OTHER PROJECTS, IN WHOLE OR PART WITHOUT THE WRITTEN CONSENT OF FRANK FRAZE, ARCHITECT, AIA. ALL RIGHTS ARE RESERVED BY THE ARCHITECT IN ACCORDANCE WITH U.S. COPYRIGHT AND PATENT LAWS. UNAUTHORIZED REPRODUCTION WILL BE PROSECUTED TO THE FULL EXTENT OF THE LAW. 0 0 N 0 O ICI � Was O ��4 o o W �1,4 4 o W �x PROFESSIONAL SEAL �®®�'ia Haase®o .� DALE® ON,3 �® • T�ATF- OF ° f�_ 0 ON VINCEN.801t-e6NARDO FLORIDA P.E. #58009 P I' � I' � V� v I M 00 m Q � Z � N � U cn00 w a F N 0 � � M 00 N M N w W W � 00 M -d N M w � u V7 w�a SHEET TITLE MECHANICAL PLANS SHEET NUMBER L m ................... I SANITARY WASTE + VENT PLAN P-1 I SCALE: 1/4" = V-0" NORTH 2 DOMESTIC WATER SUPPLY PLAN P-1 SCALE: 1/4" = V-0" NORTH PLUMBING LEGEND NEW SANITARY WASTE PIPING NEW COLD WATER PIPING — — — — — NEW HOT WATER PIPING --v--- v ---v —— NEW VENT PIPING p POINT OF COINNECTION GLOBE SHUTOFF VALVE GENERAL NOTE 2007 FPC SECTION 422 "HEALTH CARE FIXTURES & EQUIPMENT SHALL BE APPLICABLE THIS PROJECT. ALL FIXTURES AND INSTALLATION METHODS SHALL COMPLY. FAN DCH PROJECT NUMBER: 11-002 TO THE BEST OF THE KNOWLEDGE OF THE ARCHITECTS AND ENGINEERS, SAID PLANS AND SPECIFICATIONS COMPLY WITH THE 2007 FLORIDA BUILDING CODE WITH 2O09 SUPPLEMENTS AND THE APPLICABLE MINIMUM FIRE SAFETY STANDARDS. ALL DIMENSIONS AND JOB CONDITIONS SHALL BE VERIFIED BY THE CONTRACTOR, ANY AND ALL DISCREPANCIES SHALL BE REPORTED TO THE ARCHITECT PRIOR TO COMMENCEMENT OF CONSTRUCTION. THE DRAWINGS & DESIGN ARE VALID FOR 12 MONTHS FROM DATE OF ORIGINAL SEAL. m ¢ U Z Q Q w IV ¢ Of w z I Z z Lu w 0 w IV ¢ 0 0 CN U O U ISSUE DATE REVIEW 1 /27/11 PERMIT 1 /27/11 REV. Q 3/10/11 REV. REV. REV. THESE DOCUMENTS, DESIGNS, NOTES, DETAILS AND SPECIFICATIONS AND CONCEPTS ARE THE SOLE PROPERTY OF FRAZE DESIGN, INC. AND SHALL NOT BE REPRODUCED, RE -USED OR COPIED FOR OTHER PROJECTS, IN WHOLE OR PART WITHOUT THE WRITTEN CONSENT OF FRANK FRAZE, ARCHITECT, AIA. ALL RIGHTS ARE RESERVED BY THE ARCHITECT IN ACCORDANCE WITH U.S. COPYRIGHT AND PATENT LANE. UNAUTHORIZED REPRODUCTION WILL BE PROSECUTED TO THE FULL EXTENT OF THE LAW. 0 0 N O *Ak W v1 O O h� O COD 0 a 1 FT o W �� •0 U �N PROFESSIONAL SEAL ��$4431122its�a `q R • „ aaa too. 5$0 F a�o STATE • s VINC�t"Tpo !"NLEONARDO FLORIDA P.E. 458009 k I 00 g M 00 M N 00 U a W 00 � C7 PSG W W ao F� � M i 00 N M 11 rl N w w w 0 ® 00 M �� � N 00 N M W � 0 � W w � a SHEET PLUMBING TITLE PLANS SHEET p NUMBER I A.= p