Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
3149 Moulden Hollow Dr
Y ABBREVIATIONS A.B. Anchor Bolt F.P. Fireplace P.T. Pressure Treated Abv. Above F.O.M. Face Of Masonry Pwd. Powder Room A/C Air -Conditioner Ft. Foot/ Feet Rad. Radius ADJ. Adjustable Ft . g Footing g Ref. Refrigerator A.F.F. Above Finished Floor FIX Fixed Req d. Required A.H.U. Air Handler Unit ALT. Alternate Galy. Galvanized Rm. Room B.A. Base Cabinet G.C. General Contractor Rnd. Round BF Bifold Door G.F.I. Ground Fault Interrupter R/S Rod and Shelf Bk Sh BookShelf G.T. Girder Truss SD. Smoke Detector Bm. Beam Hdr. Header S.F. Square Ft. Bot. Bottom Hgt. Height Sh. Shelves B.P. Bypass door HB Hose Bibb SHT Sheet BRG. Bearing Int. Interior S.L. Side Lights Cir. Cig. Circle Ceiling K/Wall Kneewall S.P.F. Spruce Pine Fir CJ Control Joint K.S. Knee Space Sq. Square Col. Column Laun. Laundry S.Y.P. Southern Yellow Pine Comm. Community Lay. Lavatory TB Towel Bar Comp. Compressor L.F. Linear Ft. Temp. Tempered C.T. Ceramic Tile LL Lintel Length Thik'n. Thicken D. Dryer Tub T.O.B. Top of Block DB Door Bell M as. Masonry ry T.O.M. Top of Masonry Dec. Decorative T.O.P. Top Plate Ded. Dedicated Outlet Max Maximum TR TOWEL RING Dbl. Double M.C. Medicine Cabinet Dia. Diameter Mfgr. Manufacturer TP TOILET PAPER Disp. Disposal Micro. Microwave Trans. Transom Window Dist. Distance Min Minimum Typ. Typical D.S. Drawer Stack M.L. Microlam U.C. Under Counter D.V. Dryer Vent Mir. Mirror UCL Under Cabinet Lighting D.W. Dishwasher U.N.O. Unless Noted Otherwise Ea. Each Mono Monolithic V. Shower Valves E.W. Each Way N.T.S. Not to Scale VB Vanity Base Elec. Electrical Opn'g. Opening Vert. Vertical Elev. Elevation Opt. Optional V.L. Versalam Ext. Exterior Pc. Piece VTR Vent through Roof Exp. Expansion Ped. Pedestal w Washer FBC Florida Building Code PH PHONE W/ With Fin. Fir. Finished Floor P.L. Parallam W/C Water Closet F.G. ixed Glass PLF Pounds per linear foot W.A. Wedge Anchor Fir. Floor Pit, HI. Plate Height Wd Wood Fdn. Foundation Pit Sh. Plant Shelf WP Water Proof Fir Sys Floor System PSF Pounds per square foot REVISIONS 08-20-15 1.00 NEW BASE PLAN 12-8-15 2.00 ADDED VAULT. CLG. in #U1 11, Sus 1941 INDEX OF DRAWINGS SHEET DESCRIPTION SHEET No. CS COVER SHEET 1 FLOOR PLAN 2 INTERIOR ELEVATIONS 3.1 EXTERIOR ELEVATIONS 3.2 EXTERIOR ELEVATIONS F1 FOAM DETAILS 4 ELECTRICAL PLAN 5 ROOF PLAN 6 FOUNDATION PLAN 7 ROOF FRAMING PLAN 8 LINTEL DETAILS SN STRUCTURAL NOTES SN1 DETAILS S3S STEM DETAILS S4 DETAILS S5 DETAILS SS RETROFIT DETAILS D1 SECTIONS & DETAILS WP WATERPROOFING DETAILS PA1.0 PRODUCT APPROVAL NUMBERS PA1.1 PRODUCT APPROVAL NUMBERS PA1.2 PRODUCT APPROVAL NUMBERS PA1.3 PRODUCT APPROVAL NUMBERS ALL WORK SHALL COMPLY WITH PREVAILING DES NATIONAL E FLORIDA ECT DING CODE, AND THE CITY OF ZEPHYRHILLS CVO CITY .. LS MEAN ROOF 15 FT. HIGH TYPICAL FOR SINGLE STORY HOMES MEAN ROOF 30 FT. HIGH TYPICAL FOR 2 STORY HOMES THIS DRAWING AND DESIGN IS VALID FOR 12 MONTHS AFTER THE DATE IT IS SIGNED AND SEALED OR WHILE CURRENT CODE IS VALID Notice to Builder & All Subcontractors It is the intent of Designer/Engineer listed in the titleblock of these documents that these documents be accurate, providing Licensed Professionals clear information. Every attempt has been made to prevent error. The Builder and all subcontractors are required to review all the information contained in these documents, prior to the commencement of any work. The Designer/Engineer are not responsible for any plan errors, omissions,or misinterpretations undetected and not reported to the Designer / Engineer prior to construction. All construction MUST be in accordance to the information found in these documents. Any questions regarding the information found in these plans should be directed to our Office at (407) 880-2333 immediately. No backcharges will be considered for reimbursement by the Designer/Engineer without advanced notification and approval by the Designer/Engineer. Payments will be made in accordance to the terms of the agreement. (D�2 z(oz° z Q WV) C� vw O w V) E E o o 0 �mti U M w i— E N C: M 0 T:O R) O — =ai o 0 :5LLco //`\ In N 0 co aO Y Q °o� q.LO V rn Q 0 A I N- C B D C c CID � o ro v o - o N7o CV 0 Co.. Z��� N r Z M 0� c / - (7 LL 0 Z _I lC a W.. '- N T R.t1I W u V¢'Q �. Z 0 Q o � 9 o aY 0 , ZH.o^w mO° a�.<N�: IL d W N ¢ co `s O'O V . ❑ ❑ To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code 5th Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. O 0 Z tV 0 � n C:) �> Q �- V) L G( LL c' M ice V OL 00 Q E Z W.W_I J oZ �o W� Zg ga Lu Z t~� 00 U Z La < U= w Z w ~ Lu " 8 Lu d— w w Wo o /3{ T + Zz Q U > Z w Z) IM Lu 0 p o J Q o� a�QZO o ULU N Z�oa J Q V Q Q Q ~~g R 0 Z Wo,�o z J Lr) WW o w u Q A1""l T'-I Q z a�z a Z k CYZ O _ �Z LU SCALE : AS NOTED DATE : 2/24/2014 TECH: ERAND VERSION N0. 10 O SHEET NO. CS A S3 D S3 H.B. T 00 T P ° ° 5-SH 6" DP*-- - - - - R&S - - - BUILDER TO PROVIDE 1-----__---- l— 36 I N APPLIANCE I I I I I INE PROTECTION I I I -(-- _- - ' OWNER'S SUITES-_ - - W.I.C. , WHEN REQUIRED 2'-6" PER FBC I I I I I I I Y ■co 8'-0" CLG. - - 4 ------_ 8'-0" CLG.00 I I I I CARPET TILE� — - CARPET ;� 1 2 CAR GARAGE I I I CO O � � 17'-O$„ I r _ I _ = —1 --' r -- I 7'-8" ,= •rs I � ,� 8 -0 CLG. 2048„ I I I I 17$„I I le "W Tz — - — 5=$.,� - �— j 0' 2668 I I I 1 O I I HANSON I I p I I -__ ___ __ _- I BOX @ 36" EDGE OF SLAB 2" 1 i7 I 1 1 o v 0A.F.F. BEYOND WALLv=60"x36" rFBER - DRYER VENT S3 I W SHOWER THRU ROO I I >CD S3 1 (4) 2x4 #2 SYP STUDS SS R&S I 1 1 I1 xW/ "° cli USP HTT4 @ BASE D I I I I I T I I TYP @ 1 STORY A 64" I 4'-0" _ PT. W OPT. D IgoI NI I I I I I 33 ( Md' N Ilx IW� Q JI NOTE: FINISHED 7 WALLS TO BE I I F �l ( AHU r0,r-C�G. I FLUSH. VERIFY IN FIELD. I I r- ITILE 1 I 1 K (4) 2x4 #2 SYP CC D S3 STUDS W/ USP HTT4 BASE 53 S3 ,' - 868 ' FAMILY R M R.A.G.__ @ o OLO ^ 2:12 VAULTED CLG. _ ^ 9'-4" CLG. �- --a--T--i-- ., CARPET 3068 I I o co (9'-4 CL i A I ENTRY - 23'-Og„ in T-10" T-8" 10'-10$„ LE- 6 - 7 „ 4„ 8'-0" CLG. + - --- HDR AT T-4" rw J5, = -------R&S------ =M 2668 rco _ �100 R&S 2668 T P------------ 4'-0" 1 V-78„ 6'-10„ `44, 7„ 8'_g" i� 5-4`� 14'-6" 5'-4" �' I N 7'-6" - CV 5068 B.F. 1 4068 B.F. LID OPT. o i RE� BEDROOM 2 " W �o W'`'° 1 -- ---_ --- - --r-. T PATIO CAFE ______________ --- `1 - .. .. BEDROOM 3 N T o BED8R,OOM 4 , - -� - 8'-0"CLG. CARPET W r o o . 3 D.W. aD 8 :34--- I CARPET I 8-0 CLG. Ai I H �W v,m A o d --{--a---- 0o in cOn l� co 1 Q i�i > -' U I iP �_ CARPET I I ILE, .. MM CARPET Mw I SI K w/ ISP 20,- $„ --� ,- 2 - „ 2 I „ 10, 10'-42' 2'-4" I ^ J 5'-3 „ C)rLrn COO i--;- w � 11 m I 023 0 P- LI � 2" oa —r NT Y o- M�- 00 B-� I TYP @ 1P STORY LU 0?0FLT CLG, 36 36 T FIBERGLASS Mim I SC? -I -TILE O 0 ---�- 5-SH 16" DEEP SURROUND 0 N N H.B EGRESS EGRESS A OS3 O 29'-8" HEADER SCHEDULE MARK HEADER SIZE REMARKS H 1 (2) - 2X6 #2 SYP W/ 1/2" FLITCH PLATE H2 (2) - 2X8 #2 SYP W/ 112" FLITCH PLATE H3 (2) - 2X10 #2 SYP W/ 1/2" FLITCH PLATE H4 (2) - 2X12 #2 SYP W/ 1/2" FLITCH PLATE H5 (2) - 1 3/4" X 11 1/4 LVL 2.0E Fb=2950 H6 (2)- 1 3/4" X 9 1/4" LVL 2.0E Fb=2950 H7 (2) -1 3/4" X 16" LVL 2.0E Fb=2950 H8 (2) - 1 3/4" X 7 1/4" LVL 2.0E Fb=2950 (2) - 2X4 #2 SYP W/ 112" Follow Q/S4. See Plan for R.A.G. FLITCH PLATE Bearing Wall Call Out When Straps are Required * VERIFY W/ PLAN CORRECT LENGTH OF HEADER REQUIRED ** SEE PLAN FOR DETAIL CALL OUT FOR CONNECTIONS AND REQUIRED STUDS WINDOW SCHEDULE SIZE R.O. CMU (Flange) R.O. FRAME (Fin) TYPE 12 20 X 26 18 J X 25 z S.H. 13 20X38$ 18JX37j S.H. 14 20 X 50 5 18 2 X 50 S.H. 15 20 X 63 18 3 X 62 1 S.H. 16 20X72 182X71j S.H. 2 32 27 1!4 X 26 26 X 25 # S.H. 133 27 1/4 X 38 $ N/A S.H. 3134 27 a X 50 a N/A S.H. 2 33 N/A 26 x 37 1 S.H. 2134 N/A 26 x 50 S.H. g 35 27 J X 63 26 X 62 1/2 S.H. z 36 27 1 X 72 26 X 71 1/2 S.H. 22 37 4 X 26 36 J X 25 1/2 S.H. 23 37 a X 38 a 36 i X 37 3/4 S.H. 24 37 a X 50 58 361 X 50 S.H. 25 37 J4 X 63 36 J X 62 112 S.H. 26 37 J X 72 36 z X 71 1/2 S.H. DOUBLE 2 WIDE 75" TALL 73 J WIDE S.H. 32 54 X 26 52 � X 25 2 S.H. 33 54 X 38 j 52 J X 37 j S.H. 34 54 X 501 52 J X 50 S.H. 35 54 X 63 52 2 X 621 S.H. 36 54 X 72 52 j X 71 j S.H. 39X59 40 X 59 N/A S.H. DOUBLE 39X59 79 X 59 N/A S.H. General notes R302.5 Dwelling/Garage Opening/Penetration Protection. • Openings from a private garage directly into a room used for sleeping purposes shall not be permitted. Door between garage and residence shall be equipped with solid doors not less than 1 3/8" in thickness, solid or honeycomb -core steel doors not less than 1 3/8" thick, or 20-minute fire -rated doors, equipped with self -closing device. • Duct Penetration. Ducts in the garage and ducts penetrating the walls or ceilings separating the dwelling from the garage shall be constructed of a minimum No. 26 gage (0.48 mm) sheet steel, 1 inch minimum rigid nonmetallic class 0 or classl duct board, or other approved material and shall have no openings into the garage. • Other penetrations shall be protected as required by section R302.11, Item 4. R302.6 Dwelling/Garage Fire Separation. The garage shalt be separated from the dwelling as per the following: • From the Residence & Attics - Not Less than 1/2" Gyp. Bd. or equivalent applied to garage side. • From Habitable Rooms Above Garage - Not Less than 5/8" Type-X Gyp. Bd. or equivalent. • Structure(s) Supporting Floor/Ceiling Assemblies - Not Less than 1/2" Gyp. Bd. or equivalent. • Garages Located Less Than 3 Feet From Dwelling On The Same Lot - Not Less than 1/2" Gyp. Bd. or equivalent applied to the interior side of exterior walls that are within this area. R312.2.1 Window Sills. In dwelling units, where the opening of an operable window is located more than 72 inches above the finished grade or surface below, the lowest part of the clear opening of the window shall be a minimum of 24 inches above the finished floor of the room in which the window is Iocated.Operable sections of windows shall not permit openings that allow a 4-inch-diameter sphere where such openings are located within 24 inches of the finished floor. Chapter 45 Private Swiming Pools, Section R4501.17.1.9 All doors and windows providing direct access from the home to the pool shall be equipped with an exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 db a at 10 feet. Any deactivation switch shall be located at least 54 inches above the threshold of the access. Separate alarms are not required for each door or window if sensors wired to a central alarm sound when contact is broken at any opening. M1507.2 Recirculation of Air. Exhaust air form Bathrooms and toilet rooms shall not be recirculated within a residence or to another dwelling unit and shall be exhausted directly to the outdoors. Exhaust air from bathrooms and toilet rooms shall not discharge into an attic, crawl space or other areas inside the building. GAS APPLIANCES G.C. to verify location of gas riser before commencement of work. see Sht. SN1 for installation detail. Where gas water heaters are installed. Water heaters shall be installed a min. of 18" above fir, per FBCR G2408.2. Except where appliances that are listed as flammable vapor ignition resistant. OPENING PRESSURES ENCLOSED-EXPOSURE"C" O +25.6 / -27.8 © +25.6 / -34.3 © +24.5 / -26.7 (b) +24.5 / -31.9 �E +23.0 / -25.2 �F +23.0 / -28.9 6W;9"" NOTE: WIND SPEED INDICATED ABOVE IS AN "ULTIMATE" WIND SPEED. THE WIND PRESSURES LISTED ABOVE ARE ALLOWABLE PRESSURES WALL LEGEND [IIIIIIIIIIIIIIIII TYP. 2x FRAME WALL BEARING WALL INTERIOR BEARING WALLS NOTED "FLOOR BEARING ONLY" ARE FLOOR SYSTEM SUPPORTING ONLY AND REQUIRES NO UPLIFT CONNECTORS TO FLOOR SYSTEM AREA TABULATION "A1" 1ST FLOOR LIVING AREA 1936 LIVING TOTAL 1936 GARAGE 416 FRONT ENTRY 20 TOTAL AREA 2372 INSULATION REQ. LOCATION R-VALUE / TYPE EXT CONC WALL R-4.1 HIGH PERM EXT FRAME 2 x 4 R-11/R-13 KRAFT FACED EXT FRAME 2 x 6 R-19 KRAFT FACED CONDITIONED CEILING R-30 BLOWN -IN (INSTALL BAFFELS AT EAVE) GARAGE SEPARATION R-11/R-13 KRAFT FACED (GARAGE / LIVING) a (D!P Z o - C) Z Q 0 Q) cn -I---� w ru .0 — 0 w o o0 m� w a) M rnmc') ~ v @ "O M O 00 = ai ( U m sE00 Q .Y U) LO O < 0 rn o 1 N C B D C TZ 3;,,� .150 rreep� � i �J � r.i:� .� OCA ��I a Q tee: >ll ¢ ` Z� o o .mt, W a C-a �4 To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code 5th Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing. Engineer's signature and seal. O � Z M O z r) a Ln a�'°'� 0-fu M oC U Q, '—' Q � E zca J� W Oz �o z 2 <¢ H �J¢000 zo U Z a w Z y�z W ¢ � � J r—I J ffi O � w W mz0 ozZz rr Qo Imo- > � ® g V)� wV IM ILL. O O I o o U = r ^ 1• L T J a J U Lu Uj o� � Q{� yx, seO X OU � a cV 0 Z<�< � J Z ��o $0 z z o LU Lli IJJ a E = o i.Lcc.,l G o W U LL Y Q Q r� 1` Z LU i- Ln Z a< O az d to F� SCALE : AS NOTED DATE : 2/24/2014 TECH: ERAND VERSION N0. 10 SHEET NO. 1.0 6 0 00 b� MIRROR 0 ih 11 E OWNER'S BATH o IO 01 0 DW KITCHEN ISLAND _+ i ! i- OWNER'S BATH KITCHEN 8c 9'-11 Q" Z-84' MIRROR 0 M - o !! I -I-- Lij KITCHEN BATH 2 0 (V 0 M INTERIOR ELEVATIONS_ U rU3 UHz� z� C� z 0 V) U w �U — O w E o r^ v , � V) F— O M m V w Ctan O — � 2 :O M N O 00 _ ai U s LL ao 1)Y� C Y O ¢ m 0) Q O w 1 N,C B*D*C i C r B D. h'm, };.-r CN LL �f O '4ya5J+' 'V v°r c u- Z U)�0 Uj c _ o� c au^ fi N dui' ,.,• ®„ LL N Mi oe �❑ ❑ To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code 5th Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. O C) Z N 0 N I� t-•i 4 -' p r>—i M O a'(10`r) d' d V)z LI) G( LJ LL C- M Q� U fl. 00 ¢ ot� E z Uj (:� J C) W d' oZ o �Ln w � z as za �zag�a z0 U Z UUJwL =nWz 0 Lo OW W O W z z Q U W z O �3 2 ULJ A� J ' N U o m a a o¢oa ¢ aoW� Fro 10�o Z Z W Lr) W a F �� o .I { n O Z 8 a ¢ W ~ z ,-4 ¢ z a�z a N U) Z o _ ¢ z SCALE : AS NOTED DATE : 2/24/2014 TECH: ERAN D VERSION No' 10 O SHEET NO. 2.0 ao C a TOM - -- 12 5[:::T,, EXTENDED OVERHANG TO BE CENTERED - ON DOOR 3 TAB SHINGLES. ROOF INSTALLED AS PER MANUF —�� SPECIFICATIONS ------------ TEXTURED CEMENTICIOUS FINISH ON C.M.U. (TYP.) REAR ELEVATION - Al SCALE: 1 /4"=V-0" 3 TAB SHINGLES. ROOF INSTALLED AS PER MANUF. SPECIFICATIONS 15'-0" RIDGE VENT 14'-0" RIDGE VENT T.O.M. - --,-_,---- T--,--,._��--�-----�-T- -- -------�-- ----------- —- T---- ,- ___ ----- - - - -- --- --= - ------ - _ _ --- --- -- - - - - - - - - _ - - - - -- - - - - - - - - - HDR HGT. - — -q— — — — — — — — — — — — — — — — 1'-0 TEXTURED " TEXTURED CEMENTICIOUS CEMENTICIOUS FINISH ON C.M.U. FINISH ON C.M.U. 2'-0" (TYP.) (TYP.) F.FL. RIGHT ELEVATION - Al 1/4"=1'-0" General Notes ROOF CRITERIA: • 12" OVERHANG U.N.O. • PLUMB CUT FASCIA ROOF • PITCH PER ELEVATION .G.C. VERIFY ROOF PITCH" ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE CONTRACTORS RESPONSIBILITY TO VERIFY ROOF SLOPE REQUIREMENTS WITH TRUSS MANUFACTURER. "ELECTRICAL SPECIFICATION NOTES" ELECTRICAL CONTRACTOR MUST VERIFY WITH THE SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT FIXTURES SHOWN ARE FOR LOCATION PURPOSES. Exterior Covering R703.6 Exterior plaster. Installation of these materials shall be in compliance with ASTM C 926 and ASTM C 1063. R703.6.1 Lath. All Lath and lath attachments shall be of corrosion -resistant materials. Attached per ASTM C 1063, R703.6.2 Plaster. Plastering w/ portland cement plaster shall be not less than three coats when applied over metal lath or wire lath and shall be not less than two coats when applied over masonry, concrete. R703.6.3 Water-Resisitive Barriers. Water-resisitive barriers shall be installed where cement plaster (stucco) is to be applied over wood -based sheathing, shall include a water -resistive vapor -permeable barrier. The individual layers shall be installed independently such that each layer provides a separate continuous plane and any flashing intended to drain to the water -resistive barrier is directed between the layers. The barriers shall consist of one of the following. 1. Two layers of an approved water resistant barrier material in accordance with R703.2. 2. One layer of an approved water -resistive barrier (paperbacked stucco lath) over an approved synthetic house wrap. R703.8 Flashing. Approved corrosion -resistant flashing shall be applied shingle -fashion in a manner to prevent entry of water into the wall cavity or penetration of water to the building structural framing components. Flashing shall be installed at the following locations. • Exterior window/door openings. • Intersection of chimneys or other masonry contructions with frame walls. • Under and at the ends of masonry, wood or metal copings and sills. • Continuously above all projecting wood trim. e Where exterior porches, decks or stairs attach to a wall or floor assembly of wood -frame construction. • At wall and roof intersections • At Built-in gutters. Attic Ventilation Attic Ventilation to be in compliance with the Florida Building Code 5th Edition (2014) Residential R806. The Minimum net free ventilating area shall be 1/150 of the area of the vented space. The ventilating area may be reduced to 11300 provided that at least 40% but no more than 50% of the required ventilation is provided in the upper portion of the space to be ventilated.Upper ventilators shall be located no more than 3 feet (measured vertically) below the ridge or highest point of the space, with the balance of the required ventilation provided by eave or cornice vents. **CALCULATIONS BASED ON THE FOLLOWING VALUES, SEE ROOF PLAN*" (Values to be verified with Manufacturer Specifications) • RIDGE VENTS 15 SQ. IN. OF NET FREE AREA / LINEAR FT. • OFF -RIDGE VENTS 138 SQ. IN. OF NET FREE AREA / UNIT • SOFFIT VENTS 7 SQ. IN. OF NET FREE AREA / SQ. FT. • O'HAGIN WEATHERMASTER (Shingle Roof) - 72 SQ. IN. OF NET FREE AREA/ FT. ** (Sq. FL Soffit Needed) x 7 = (Sq. In. Needed) / 72 = Amount of O'Hagin Vents Needed • LOMANCO DECK -AIR (Shingle Roof) - 9 SQ. IN. OF NET FREE AREA / FT. * Formula: (Sq. Ft. Soffit Needed) x 7 = (Sq. In. Needed) / 9 = Linear Ft. of Deck -Air Needed) • O'HAGIN (Tile Roof) - 86.25 SQ. IN. OF NET FREE AREA / VENT **Formula: (Sq. Ft. Soffit Needed) x 7 = (Sq. In. Needed)186.25 = Amount of O'Hagin Vents Needed (DL9 Z M 0 z� d a. L/) 0 v) a--�LLJ 'U — OW N E o II^^ CO I® Od m U UaiJ N M m coF® E - ° T .c N O o 0 a) III :3 OYti i�I a) a) 1Y O Q co rn Q o 1 N.C-B-DC 13 D. C, C14 (10 04 r �.� c�' ma �; U.J. m -p atn W 3 4 m q Q�� OLL N °"� ° F - � w W a Lr ^, !t�!lili�l��1 ❑ To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code 5th Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. 0 0 Z cV 0 (U r--I a_+ O a> -I U) M O Q U7 - 2 � 0 rl-. LL Q � U Q 00, z < Z E fa LU O W Jl0 d" J O z x O w� z Qa <a ~ Cf) Z Qua z o p o U W ZF W I— Q z 2 ,n W z �0�Lq 1 ' W S W N W mzo L W > O v' Lu z z C: M u) -0 0 0 o 'CS Z < = (u r Q OW W O z ~Yt72¢¢ ` 0 °-I a W X UO U �rF. � UiY ma a cj� a o¢oa w, za H � W Z LU r~-i Lr) WDEo Q o z J T.{ W Q LLJ z o i-o 0 z U 0 Wse ~z Z W (n ¢Z O _ r la - SCALE: AS NOTED DATE ; 2/24/2014 TECH: ERAND VERSION NO- 10 O SHEET NO. 3.2 2 1" *NOTE: VARIES 1" RADIUS Cl) iv M iv f2" N � - CO FOAM TO BE USED ONLY WHEN REQUIRED BY COMMUNITY SPECS. IF NOT, DETAIL TO BE 1"�2- OPENING VARIES 2" 2" BUILT W/ STUCCO. EDGE OF OPENING N :- 3 1/2" RADIUS 3/4" RADIUS a 1/2" RADIUS 1" 4" 1/2" RADIUS 1'-53" a VARIES VARIES �M _ 0 + M r (V 22, VARIES 4" 4, & MIV' CO �� r)Iv 1 n 1 n a" 4" 42 N „r 00 3" SIN T 3" D 2„ "vi �O VARIES 12" 2 2 �IN M 32, 11" 32, 1, $„ 1 1/2" RADIUS 2 1/2" RADIUS 12' VARIES BASE SIN r t;7 r. O 3„ *NOTE: FOAM TO BE USED ONLY WHEN REQUIRED BY d COMMUNITY SPECS. IF NOT, 1" DETAIL TO BE BUILT W/ STUCCO. VARIES OPENING VARIES 2" 2" 2" g" 2" d�N 1'-s" 1" V 4" 1" `O F—E 12' `O EDGE OF OPENING • , r 24, • O 101,CV 241" `Iv _ � iT I I N r 1-1/2" THICK 1-1/2" THICK �N N r, 3++ 4 2 N 2„ 4„ 3++ 6" 2„ 2" iv W W {M 1-1/2" THICK 24+ _� r TM 2'-4" 1'-10" 4" 31" �++ 1+_5+, SZ++ IN 00 1 +„ 3„ _ N - ++ L 4 w Q � M 2 o II�'j 22' io VARIES VARIES I I 4" 8" r--------- _a 00 I M ^ . 2 41+ 6" 4" `--r N N io R�4b, 2_ NOTE: • INSTALL OVER STONE, TYP. • FIN. TO HAVE TRADITIONAL LOOK & SMOOTH FINISH VARIES • FOAM/ EPS MATERIAL IS ACCEPTED r VARIES PNEF0 . OPENING VARIES 3" a 4" NOTE: • FIN. TOHAVE TRADITIONAL LOOK & SMOOTH FINISH • FOAM/ EPS MATERIAL IS ACCEPTED 3'-$" 14, V-6a" 14. 12 f2" to co 1 " _ � v 4" T-0" 4" 10„ V-4„ 10+, 0 m iv KEYSTONE F11 OPTIONAL 00 N b CV ' 4" WINDOW OPENING 4" 5a„ 1'-12' 53„ D�� 1++ N 1 TN p') I M M r ��- RrO, r `t I —/ I GENERAL NOTES: • 1.5 LBS DENSITY STYROFOAM • POLYCOAT (HARD COAT) ACRYLIC SAND FINISH im zo z� Q J C a--� w .0 O W 1 (21- o (Jn = In Mo U C(] r L U U nC'i c� c0 aMj tV 'O co_ 0 NO N O CU-a0 7 U (D C fl o O 1 Q m U-) "t Q O N,C 6 D C ®o ti N _ N c N t7 yo o° �z o CV N ° a 0 Z W mNtiz — Z W Q�""'N °U-j W �W—��- �Q- Z a v7 O = �,o¢ (r O O LLZ Nc, o W a°'a�r- ¢ N co - C5 U O0 To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code 5th Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. 0 Z N O1-4 v r\ 0 Q (1) 0 Lr) a V) a LZ LL '� a H z Q UD 00 \J E z� WJ C:) d' Oz F O w � z a z� <¢ W¢�0, U z O O U Z U Z Q J mlwz Lq U LL N W W Qzz o Lu Ln >0 az TI 5 cc: a z c M F-- oC o Q O z �a U = ^_�� C� Woo LU U E! m J N z Q 0 Q Wo J w c� z; 20 z z C,.o W a z LU J Lln >� L1.1 '<,Ru..o ,-1 ¢ Z z Q z aun m 0 ^ = QLn z SCALE : AS NOTED DATE : 2/24/2014 TECH: ERAN D VERSION N0. 10 O SHEET NO. F 1 ELECTRICAL SPECIFICATION 200AINDEL CENNTERTER NOTES: #14 copper to lights &outlets ELECTRICAL CONTRACTOR NEMA 1 200 AMP 10 #12 copper to 20 amp ckts MUST VERIFY WITH THE 10 #10-2 copper to WH SPECIFICATIONS FOR THE TYPE 10 #10-3 copper to Dryer OF FIXTURE TO BE USED. LIGHT FIXTURES SHOWN ARE FOR METER T LOCATION PURPOSES. MAIN 2/0 or 4/0 SER Alu 200 amp 150 amp POWER CO. FEED INTERSYSTEM BONDING O TERMINATION PER 71 NEC 08, 250.94 J 4 Bare Cu Ground CLAMP PER 250.50 AND 250.52 OF THE 2011 NEC. GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2011, LOCAL CODES AND THE LOCAL POWER CO. 1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF (general) kitchen 44" AFF bathroom 39" AFF laundry room 36" AFF exterior waterproof 12" AFF garage general purpose 42" AFF range 2" AFF 2. All trim plates & devices to be ganged, where possible. 3. Electrical switches to be at 42" centerline above finished floor. 4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the installation & sizing of all electrical, wiring & accessories. 5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. 6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch circuits in all dwelling units per NFPA 70 and the 2011 NEC. 7. Provide Tamper Resistant Receptacles as required by the 2011 NEC, 406.11 8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and vapor detector sensor, according to the installation. 9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a Nationally Recognized Testing Laboratory. 10. Keep all smoke detectors minimum of 36" from bathroom doors 11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be equipped with a monitored battery backup. 12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits is not acceptable. 13. All doors and windows providing direct access from the home to the pool shall be equipped with an exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning when the door or window are opened.. 14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' if the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacles outlests shall not be required on a wall directly behind a range or sink to fulfill the requirement for an outlet every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and 18" for sinks and ranges installed in corner counters. ELECTRICAL KEY DUPLEX CONVENIENCE OUTLET DUPLEX OUTLET ABOVE COUNTER W.P. WEATHERPROOF DUPLEX OUTLET G.F.I. GROUND FAULT INTERRUPTER DUPLEX OUTLET HALF -SWITCHED DUPLEX OUTLET I� SPECIAL PURPOSE OUTLET DUPLEX OUTLET IN FLOOR 220 VOLT OUTLET WALL SWITCH THREE-WAY SWITCH �'4 FOUR-WAY SWITCH $R RHEOSTAT SWITCH CEILING MOUNTED LIGHT FIXTURE WALL MOUNTED LIGHT FIXTURE ORECESSED LIGHT FIXTURE P.C. LIGHT FIXTURE WITH PULL CHAIN TRACK LIGHT FLOURESCENT LIGHT FIXTURE O EXHAUST FAN EXHAUST FAN/LIGHT COMBINATION ELECTRIC DOOR OPERATOR (OPTIONAL) CH CHIMES (OPTIONAL) 0 PUSHBUTTON SWITCH (OPTIONAL) SD SMOKE DETECTOR CM SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) TELEPHONE (OPTIONAL) © TELEVISION (OPTIONAL) ©V 2 (2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. O THERMOSTAT ELECTRIC METER _a ELECTRIC PANEL DISCONNECT SWITCH SPEAKER (OPTIONAL) �7 ROUGH -IN FOR OPT. CEILING FAN v J c� CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR G J OPT. CEILING FAN W (1) PHONE LINE, (1) DATA PORT u RECEPT. FOR ALARM SYSTEM I OWNER'S S��I ITE -- -�- 0 A -� W.I.C. '1'-- ' / ROUGH -IN FOR OPT. CLG. FAN/ I LIGHT PRE -WIRE _ I 0 P------------f ----� t k - � Y ?�I PA 10 CAFE IN, I I FAMILY RM ROUGH -IN FOR OPT. CLG. FAN/ LIGHT PRE -WIRE I I GFI I F I -- - ' I o D.W. ' L-__J INK / DIS - U. IT H PENDANT AS \ PER SPECS � r EP)ADL WP H.B. GFI DISC. DEDICATED RECEPTACLE FOR MICROWAVE RANGE HOOD PER SPECS ®L 'MI VERIFY METER LOCATION WITH BUILDER H.B. IRRIGATION VERIFY LOCATION GFI @ 44" A.F.F. W H ELECTRICAL PANEL I O 1 I I I 2 CAR GARAGE I I GFI FOR GAR. DOOM GFI -_GFI @ 44" A.F.F. I I _ I I A I I / 1 II I L------------ GFI @ 44" A.F.F. I ENTRY I ' I WP j GFI I BEDROOM 4 ROUGH-IN FOR 7L-t OPT. CLG. FAN/ LIGHT PRE -WIRE MAIN FLOOR ELECTRICAL PLAN SCALE: %4"=V-0" (Dr Z (M 0 — o z� z� Lu Q o z O n07 W 'I--J LLJ Q Ow ry E o 107 c J v , F (� M c m r` U 0, W H o Ct to M N .0 M — Q O 20 = a)= U LL co to C n ao 4 Q tT u7 O V CL 0) Q O A' B D. N C a D C N N N �fl Lo .n N oo `- o rn o0 V o o N 'Z iCi Z W �Nnz —� w_ � c LL o o z , J LU �y�N W Q CL ozo j aW Z m Z o a .n 1A a c O m OHO IUL (10, dM Wa°<NIt_t_ V M Jo In U V O To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code 5th Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. O ON Z O � n 0 f>-+HMO Q J) - d ( i L_ Q U_ F— 0-11-1-1 UQ00 Q �� Z W d' J oZ = ZU) Lo LU Z g Z z <a } UzQ�a Q g450 J Z.za �oWZ J 2_uj o O o OV U w N FWo L. oN o /1 / U Z Z Z g in� W (� LJ S 1 � O _fu O O a w o QLL_ Y O J 7OC� ul 2 ma N Q a a Z�� ��¢ce `tOw3 Z o � o WC-) LJJ �¢�_ J �.{ L.Ic..I N o owu w Y r� \ G Q H rl Ln Q Z Z ¢�Z a� z m 0 _ ¢o LZU SCALE : AS NOTED DATE : 2/24/2014 TECH: ERAN D VERSION N0. 2.,0 SHEET NO. 4.0 L!. Y!r'. vIIII III a !•._�L-_. I. VENTED SOF 46 SQ. FT. VCIN I GV O%j-r-I I V/ JV(. r l . ATTIC VENTILATION CALCULATIONS - Al ATTIC VENTILATION REQUIRED UPPER VENTILATION PROVIDED 1/150 Rule 1/300 Rule Ridge Off -Ridge (No Upper Ventilators (Must Provide Upper Ventilators) Vent Amt Amt. Req.) (Ft) Total Ventilation ATTIC Provided SPACE SQ. FT. Total SQ. SQ. FT. SQ. IN. of by Upper SQ. IN. of ventilation of vented IN. of of vented ventilation to be provided SQ. IN. of SQ. IN. of Ventilators (See Elev ) required soffit ventilation soffit by upper Ventilation Ventilation needed required needed ventilators Main 29.00000 1.000000 Floor 2373 2278 325 1139 81 570 0 573.0 435.0 138.0 (Zone 1) ""NOTE** GENERAL CONTRACTOR MUST ENSURE THAT PROPER VENTILATION IS PROVIDED AT EAVES/SOFFITS AS REQUIRED BY FBC 5th ED. RESIDENTIAL. VENTED SOFFIT LEGEND 71 IF SOFFIT IS LABELED AS "NON -VENTING" FIRE PROTECTION WILL BE INSTALLED AS REQUIRED BY SECTION R302 OF THE FBC 5th EDITION (2014) RESIDENTIAL. IF LABELED AS "VENTED", NO FIRE PROTECTION WILL BE REQUIRED. VENTED SOFFIT '3OFFIT ROOF PLAN SCALE: %4"=1'-0" General Notes ROOF CRITERIA: • 12" OVERHANG U.N.O. • PLUMB CUT FASCIA ROOF • PITCH PER ELEVATION **G.C. VERIFY ROOF PITCH** ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE CONTRACTORS RESPONSIBILITY TO VERIFY ROOF SLOPE REQUIREMENTS WITH TRUSS MANUFACTURER. **ELECTRICAL SPECIFICATION NOTES** ELECTRICAL CONTRACTOR MUST VERIFY WITH THE SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT FIXTURES SHOWN ARE FOR LOCATION PURPOSES. Exterior Covering R703.6 Exterior plaster. Installation of these materials shall be in compliance with ASTM C 926 and ASTM C 1063. R703.6.1 Lath. All Lath and lath attachments shall be of corrosion -resistant materials. Attached per ASTM C 1063. R703.6.2 Plaster. Plastering w/ portland cement plaster shall be not less than three coats when applied over metal lath or wire lath and shall be not less than two coats when applied over masonry, concrete. R703.6.3 Water-Resisitive Barriers. Water-resisitive barriers shall be installed where cement plaster (stucco) is to be applied over wood -based sheathing, shall include a water -resistive vapor -permeable barrier. The individual layers shall be installed independently such that each layer provides a separate continuous plane and any flashing intended to drain to the water -resistive barrier is directed between the layers. The barriers shall consist of one of the following. 1. Two layers of an approved water resistant barrier material in accordance with R703.2. 2. One layer of an approved water -resistive barrier (paperbacked stucco lath) over an approved synthetic house wrap. R703.8 Flashing. Approved corrosion -resistant flashing shall be applied shingle -fashion in a manner to prevent entry of water into the wall cavity or penetration of water to the building structural framing components. Flashing shall be installed at the following locations. • Exterior window/door openings. • Intersection of chimneys or other masonry contructions with frame walls. • Under and at the ends of masonry, wood or metal copings and sills. • Continuously above all projecting wood trim. • Where exterior porches, decks or stairs attach to a wall or floor assembly of wood -frame construction. • At wall and roof intersections • At Built-in gutters. Attic Ventilation Attic Ventilation to be in compliance with the Florida Building Code 5th Edition (2014) Residential R806. The Minimum net free ventilating area shall be 1/150 of the area of the vented space. The ventilating area may be reduced to 1/300 provided that at least 40% but no more than 50% of the required ventilation is provided in the upper portion of the space to be ventilated. Upper ventilators shall be located no more than 3 feet (measured vertically) below the ridge or highest point of the space, with the balance of the required ventilation provided by eave or cornice vents. **CALCULATIONS BASED ON THE FOLLOWING VALUES, SEE ROOF PLAN** (Values to be verified with Manufacturer Specifications) • RIDGE VENTS 15 SQ. IN. OF NET FREE AREA / LINEAR FT. • OFF -RIDGE VENTS 138 SQ. IN. OF NET FREE AREA / UNIT • SOFFIT VENTS 7 SQ. IN. OF NET FREE AREA / SQ. FT. • O'HAGIN WEATHERMASTER (Shingle Roof) - 72 SQ. IN. OF NET FREE AREA/ FT. * (Sq. Ft. Soffit Needed) x 7 = (Sq. In. Needed) / 72 = Amount of O'Hagin Vents Needed • LOMANCO DECK -AIR (Shingle Roof) - 9 SQ. IN. OF NET FREE AREA / FT. " Formula: (Sq. Ft. Soffit Needed) x 7 = (Sq. In. Needed) / 9 = Linear Ft. of Deck -Air Needed) • O'HAGIN (Tile Roof) - 86.25 SQ. IN. OF NET FREE AREA / VENT **Formula: (Sq. Ft. Soffit Needed) x 7 = (Sq. In. Needed) / 86.25 = Amount of O'Hagin Vents Needed cD t2 z o 0z� z� Q J !2. co z n) W cn 'N w � o 'u - O w I — E Of /I ^) � o V1 F— OM O w C CY) O — U aimE— E f6 6 M O o a a) V U00 W L L.L co 0Co Y L0 O O u0 v <C rn rnQ o A 1 B D. N c s o c C 't0 E t CV Z W �' ;' � NL :z C' ) w ai TR r ...�+ Lit 40 U3 � CD ,. `Z r.L O w o . 0- PI w 0,., Y.�Ema>{..! :r!(I�CRtB.sk To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code 5th Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. O zo U 0) r-, t-1 -L-' O L7-iO Q -0 Lf) ( 'i I- 0- to n Q L.L C)-e--, 170 00 Q V Q00 z E Z W._I C:) d" 0 oz �o w � Za f F: r w ¢ n VZOO U Q Z w Z = p W Z HJLL� z OLO W mz0 O Ln L (3) �• } O a �-- VT, z Z V� C: M ' C z o o Q z J Q U = (u ^ ,J > J se QQ x O V U2cr ma OQOa �Z¢ Q Q � W io Z �a LL W Ln Lij LL.j (Cz a W yr O Z o 0 v W ~ 0 ri Q z < ce as Q Qz J = ¢ z r, ,—I a to SCALE : AS NOTED DATE ; 2/24/2014 TECH: ERAND VERSION N0. ^ . 0 SHEET NO. 5.0 c c d 6 -41" a 6'-0" TYP @ 1 STORY U.N.O. A S3 55'-10" 6-0" 6'-0" ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ .......... _........_........................ o0 I ----------� --- =: ° -- ° --------�: - ----- BUILDER TO �-- ------71 r 4'-0" .. 12'-1" W.H. PROVIDE APPLIANCE 2 #5 REBAR 0 0'-0- 1 : ; I ; : PROTECTION WHEN RE—, D VERTICALS w/ in ■ I I FILLED CELL :: : PER FBC 351-4" 1 20'-6" 3-1/2" MIN 3000 PSI CONC. I SLAB FOR HERNANDO `r' r I: K N J -v COUNTY ONLY `� T S3 I : S3 3-1/2" MIN 2500 PSI CONC I SLAB OVER 6 MIL VISQUEEN 2'-74" 4'-O2" VAPOR BARRIER _• :: I... :: I:■ ' — :GJ CJ 1I 0io IT � 1'-103-6"M . 15-3" ,10 c) 00 I •'I i .•••••••••.Acd •••••••••••••••• — I 1 : PT. OPT. D I : -3 1/2" 4.- I G : SLOPE b o'' 2'-6"x2'-6"X1'-0" FTG I W/ (3) #5 E.W. S3 �� I • 3'-5" 7'-1" (2) #5 REBAR F, 2'-6" x 2'-6" x 1'-0" I iv AHU I VERTICALS w/ inA4'-4 W/ (3) #5'S E.W. TYP @ 1 STORY A U.N.O. S3 I K CC I S3 ici FILLED CELL I CJ I- ( - - I- — — — .:.:.''.'.'.'.'.'.'.'.' '.'. '.'.'.'.'.'.' '.'..'.'.'.'.'.'.'.' o ... 25'-1028" i i 9'-5, g"■ ■r 00" " ¢- ¢I 2'-6 x2 6 X1 0 FTG W/ (3) #5 E.W. INDICATES FILLED CELL w/ 3000 PSI I BEAM PROVIDE /2 x 9RECESS FOR FRT. " 'n CONC. GROUT FROM FT. TOOOR I -4" I SLOPE L S3 io o LO W/ (1) #5 REBAR VERT ABOVE SLAB �!� HVAC CHASE 4'-0" 4' 4" 4'-6" I TYP @ ALL PLACES SHOWN TOP OF CONC./ PAVER T BE4" ' BASED ON 0'-0" HOOKED FTG. DOWELS 5" E BED BELOW FIN. FLR. ■ I : In IN IN ■ W/ 25" EXT. ABOVE SLAB "GF ADE 40 I % LOCATION "::::::::::::::::::::::::::::::::. ' ' ' STEEL" ��� .::::::.... L� .... ........... --------- 4'-0" i 16'-10" o ;12¢:10" o 9 STEPS AS i i I I PROVIDE 1 %" RECESS r �r REQUIRED PER FIELD CONDITIONS I FOR SGD. REFER TO I �� KITCHEN ISLAND MASON'S SLOPE FOR OPT. • ' " """"""" ' "' ' ; ���� LOW WALLS WIDTH - - - - - - - - •. 10-104' " ' ' ' .. �.. CJ:; �.____ � REF. .. CJ ■ / % CJ CJ CJ 4I •■ — — I -----_---- -- s--= -=__ :: —I F - I CHASE TO ISLAND I TYP 1 S3 ii / .. ..... I I D.W. oa f I STORY U.N.O. - CV o r op o I .i- , I I I L� �- I} f - III 60 A S3 `r' T 11' n I I � _ - - I z i / SINK / DISP f I 3 1/2" }f 16'-0" 2'-94" 6'-10" C1 / '• I I I :: 1 III o I r O st i.. ................:........ ............ ................ .�_ ............. ... ......� .............■IN ■ �. Nj......•....... �.................:_ «j... H,B 5'-4" , 1'-9$" T-22" TYP @ 1 STORY U.N.O. A S3 5'-0" 5'-0" 5'-10" T-10" L 6'-0" L 6'-0" L T-10" L 2'-1064' L 5'-11R" 5'-4" FOUNDATION PLAN SCALE: %4"=1'-0" NOTE: • WHERE PROJECT IS TO BE LOCATED IN KNOWN RADON GAS PREVALENT AREAS, APPENDIX "E" OF THE FBC 5th EDITION (2014) BUILDING IS TO BE IMPLEMENTED. CONCRETE STRENGTH IN THESE AREAS TO BE A MINIMUM OF 3000 P.S.I. THEREFORE, ANY AND ALL NOTES ON THESE PLANS THAT INDICATED 2500 P.S.I. SHALL BE REPLACED WITH 3000 P.S.I. FOR THE CONCRETE STRENGTH • SEE SHEET SN FOR SOIL & TERMITE NOTES. BORATE / BORACARE TREATED LUMBER IS AN ALTERNATE TERMITE PROTECTION TO SOIL POISONING W.W.M. PLACED IN 1/8" SAWCUT x 1/4 SLAB UPPER 1/3 OF SLAB THICKNESS WHERE OR FIBERMESH SHOWN ON REINF. SEE PLAN. FOUNDATION PLAN LU `) L CONTROL JOINT DETAIL SCALE:1 1/2"=1'-0" .; . •" :;: #5 CONT REINF. SEE FND. FOR QUANTITY #5 X 25" X 25" CORNER -_ BAR ONE FOR EA. • - HORIZ. REBAR, TYP. U.N.O. :. ;':: , ;': „': ;;:: • ; "Alternate: The reinf. bars shall be cont. around corner by cold bending the bar w/ min. bar lap of 25". TYP. CORNER BAR DTL. SCALE: 1 1 /2"= V-0" (D u' Z M 0 — o z� z Q J Z V) W U w • U — m O LU F E V) 0 M o o LUC E — ca co N '6 M O oQ = N Ua) = LL 00 � o ��o 0 Q N C B*D,C T x ® s: � z �A n LU. ��F,.i W r ✓ �f��ts ((PP 011 i t fPe : ❑ ❑ To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code 5th Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. O ON Z O N ^ ,O ►/-I M O < (0 Lr) Q U- C' F- , M = U Q '-I Q � � z WJo� 9.O oz ce w� z Qa �Q Z W V G o m �ZUo < J zUjwK U Z Q ��JoWZ Yo�eN w O �Wo oZ i zo Z j.2 a 0 Oo O � LJ._ o J _.. [o O Z w 2 oLL o Um oaoa yl CV Z W 2 J ...I ZIcy- Q Q O E z z � a0zo LU J L0 T-A w 4 w 0H ¢LLz O O c� z ose �i- T-i Q z Z QI aV) Q J p aZ O J = LU r, .-1 CL LO SCALE : AS NOTED DATE : 2/24/2014 TECH: ERAND VERSION No' 10 0 SHEET NO. 6.0 (2) (2) A A A S3 ) M CJ3 CJ5 EJ7 EJ7 S3 EJ7 ' EJ7 I EJ7 D1 EJ7 M 1 (2 X NCJ3f}Ln CJ5 EJ7 (2) X 1 , , ¢ : : : : : : : : : : Lf :: ;; :: . . . : ... co ¢ : ... ;; 111 I � j I -- '.•.'.'. '.'.'.'. EJ7 EJ7 EJ7 1 I EJ7A 1 I 1 LO Ma EJ7A S3 I EJ7A I'.'.'.'. EJ7A i: M Q U ¢ a a ¢ I EJ7A I EJ7A O a •G� � ¢r1 00 mco 7 a. EJ713 LU m EJ7B UU U LU CJ5B CJ3A ,Z, a LO A J -i U (2) A (2) (2) A S3\L-\\-0 A UPLIFT CONNECTION CROSS-REFERENCE MARK SIMPSON STRONG TIE USP MANUFACTURING, INC. 0 CONNECTOR CAPACITY FASTENERS CONNECTOR CAPACITY FASTENERS SYP SPF SYP SPF A HETA20 1810 9 - 10d x 1 1/2" HTA20 1615 1585 10 - 10d x 1 1/2" B HETA16 1810 9 -10d x 1 1/2" HTA16 1615 1585 10 - 10d x 1 1/2" C H2.5A 600 535 10 - 8d RT7A 670 565 10 - 8d X 1 1/2" D H3 455 320 8 - 8d RT3 610 525 8 - 8d X 1 1/2" E META20 1450 7 -10d x 1 1/2" HTA20-18 1400 1400 10 -10d X 1 1/2" F HHETA20 2235 10 - 1 Od x 1 112" G H10A 1340 1015 18 - 10d x 1 1/2" RT16A 1380 1160 9-1 Od X 1 1/2% 8-1 Od H HTT4 3610 3105 5/8" ANCH. / 18 10dx1-1/2 HTT4 2715 5/8" ANCH. /(20)10dxl-1/2 J HTT5 4350 3740 518"ANCH. ! 26 10dx1-1/2" HTT5 3225 5/8" ANCH. /(28) 10dxl-1/2 K HD313 * 3130 3050 5/8" DIA. BOLTS TDX2-TZ 2345 - 2 - 5/8" DIA. BOLTS L HD5B * 4505 3785 5/8" ANCH. 3/4" STUD BOLTS TDX6 5320 - 2 - 7/8" DIA. BOLTS M HD7B * 6645 5650 7/8" ANCH. 3/4" STUD BOLTS TDX10 7845 - 4 - 7/8" DIA. BOLTS N L 5 6 1165/1070 ** 1005/915 ** 8 - 10d x 3" JUS26 1115/1060** - 8 - 10d P HUS26 1550/3335 ** 1335/2820 ** 20 - 16d x 3 1/2" HUS26 1925/3295 - (20)16d x 3-1/2" Q HUS28 2000/4220 ** 1720/3125 ** 30 - 16d x 3 112" HUS28 2570/4345 - 30d -16d x 3-1/2" R MTS12 1000 860 14 - 10d x 1 1/2" MTW12 1195 1005 14-10d x 1-1/2" S MTS16 1000 860 14 - 10d x 1 1/2" MTW16 1195 1005 14-10d x 1-1/2" T MTS20 1000 860 14 - 1Od x 1 1/2" MTW20 1195 1005 14-10d x 1-1/2" U MGT/MUGT 3140 3140 22 - 10d X 1 5/8" ATR W/ 5" EMBED W/ SIMPSON "SET" EPDXY V LGT2 2150 1850 (16)16d SINKERS & (7) 1/4" x 2-1/4" TITENS LUGT2 1850 1810 (16)1Old NAILS AND (5) 1/4" x 3" WEDGE BOLTS HTS 20 1450 1245 24-10d X 1 112" HTW20 1530 1285 24-1 Od X 1 1/2" SP1 585 535 10-10d SPT22 685 8-10d SP2 1065 605 12-10d SPT24 1030 12-10d HCP2 645 555 12-10d X 1 112" * MINIMUM 3" MEMBER ** REACTIONS ARE FOR ROOF LOADS ONLY *** DO NOT DRIVE NAILS THROUGH THE TRUSS PLATE ON THE OPPOSITE SIDE OF THE TRUSS, WHICH COULD FORCE THE PLATE OFF OF THE TRUSS, ALL EPDXY ANCHORS USP CIA-7000C NOTE: DOUBLE FELT REQ'D ON ROOF PITCHES 3/12 & LOWER. LOADS -- ROOF = L / 360 FLOOR = L / 480 W! 3/8" MAX DEFLECTION. FLOOR JOIST SPACING SHALL BE MAX OF 19.2" OC FOR HARDWOOD & TILE AREA'S & 24" OC FOR CARPET AREA'S DROP HIP DETAIL 2-0-0 MAXIUM SPACING ON VERTICALS OF (B) TRUSS ++) (B) B) (A) (+) 1 OR 2 PLY Fri/ CARRIER CLEAR GAP BETWEEN (B) TRUSSES (+l- 6") 'FASTEN EACH (B) TRUSS WEB TO EACH (A) TRUSS TOP CHORD @ EVERY INTERSECTING POINT SHOWN ON THE HIP TRUSS SYSTEM BELOW. FASTEN TOP CHORDS OF EACH (B) TRUSS TO THE TOP CHORDS OF (A) TRUSSES AT EVERY OTHER INTERSECTING POINT (*"). (B INTERSECTING POINT TO BE FASTENED WITH 2 - 16d COMMON NAILS OR 0.128" x 3" GUN NAILS. FASTEN BOTTOM CHORD OF (B) TRUSS TO TOP CHORD OF CARRIER TRUSS WITH THE SAME SPECIFIED COMMON NAILS OR GUN NAILS AT 48" OC. (+) IN LIEU OF PREFABRICATED HIP PLANING TRUSSES, (B) 2x4 SO. PINE #2 OR #2 PT. STICK LUMBER (LAID FLAT WISE) MAY BE USED. FOLLOW FASTENING SCHEDULE AS DEFINED FOR HIP PLANING TRUSSES, R1 STICK FRAMING SPLICING IS ALLOWED BETWEEN TRUSSES OR AT TRUSS 1 02R CONT LEDGER (A) INTERSECTIONS. SPLICING TO BE STAGGERED BETWEEN COMMON TRUSSES, NO CATS REQUIRED UNDER STICK FRAMING SPLICING. MINIMUM LENGTH OF STICK FRAMING TO BE 5-0" ON A HORIZONTAL PROJECTION. NOTE: SEE SHEET D-1 FOR ROOF FRAMING DETAILS 1. (2) 12d TOENAILS EACH SIDE OF FLOOR TRUSS TO WALL OR BEAM BELOW TYP @ INT. BEARING U.N.O. SCALE: %4"=1'-0" I C� � o z CL. U) Z LA U u7 (DM LiJ 0 U - O 0� E 0 M � r° �('6 O o mti P9 +� L� N co mN M 0 lain 2 -S cm O 00 ai 1z, LL 00 ��� �o I= 0Qo Lo0 QCL - 4o N C B D C ?>to ".. "- =L V �� NEaa.•...ro a'dp m .1 LLW�ESS1��w`� 4= qq p !! gg ■❑ To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code 5th Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. O Z � 0 N R M O fa LIB z L 0 PG Q n LL W U Q --I Q 00 E fQ Z W-j C:) d" D oz Co G rL p z d �¢ Z WQa� U zoo o zOww< �yoWZ � V LU � � ,_o w Z �iz0 o� } O U T� CC z � z LL M C M 0 1 O ® o o J z V = (� 1J� \ O� HORZO �¢U¢' U®O� 0 co zi� cr+ O¢03 a�-- w z < Q �a L-L, 1 3.; 2) Z 202EM' owo �-i Zoz r-i Ln Q Z Z ¢ w z =O' U) L0z 0 LLJ _ ¢z r-f ri Cl- ul SCALE : AS NOTED DATE : 2/24/2014 TECH: ERAND VERSION N0. 10 0 SHEET NO. 7.0 GENERAL INSTALLATION NOTES 1, Provide full mortar head and bed joints. 2. Shore filled lintels as required. 3. Installation of lintel must comply with the architectural and/or structural drawings. 4. U-Lintels are manufactured with 5-1/2" long notches at the ends to accommodate vertical cell reinforcing and grouting. 5. All lintels meet or exceed U360 vertical deflection, except lintels 174" and longer with a nominal height of 8" meet or exceed U180. 6, Bottom field added rebar to be located at the bottom of the lintel cavity. 7. 7/32" diameter wire stirrups are welded to the bottom steel for mechanical anchorage. 8. Cast -in -place concrete may be provided in composite lintel in lieu of concrete masonry units. 9, Safe load ratings based on rational design analysis per ACI 318 and ACI 530 10. Product Approvals: Miami Dade County, Florida Nos.03-0605.05 and 03-0605.04. 11. The exterior surface of lintels installed in exterior concrete masonry walls shallhave a coating of stucco applied in accordance with ASTM C-926 or other approved coating. 12. Lintels loaded simultaneously with veritcal (gravity and uplift) and horizontal (lateral) loads shoud be checked for combine loading with the following equation: Applied vertical load + Applied horizontal load / . 0 Safe vertical load Safe horizontal load `— GENERAL CONCRETE LINTEL SCHEDULE APPROVED LINTEL MANUFACTURERS: CASTE-CRETE, QUALITY 8F44 1 B/iT 8F40 1 B/1 T 8RF40 OB/1T 8F321 B/1T TYPE DESIGNATION F = FILLED WITH GROUT / U = UNFILLED R = RECESSED QTY. OF #5 REBAR @ BOTTOM OF LINTEL CAVITY = J w 8F 16— B/1 T f- J a Z c' z tNOMINAL. QUANTITYOF WIDTH #5 REBAR AT TOP NOMINA HEIGHT MATERIALS cif precastTintels = 3500 psi. 2. fc prestressed lintels = 6000 psi. 3. grouted per ASTM C476 fg = 3000 psi w/ 4. maximum 3/8" aggregate and 8" to 11" slump. 5. Concrete masonry units (CMU) per ASTM C90 w/ minimum net area compressive strength = 1900 psi. 6. Rebar per ASTM A615 Grade 60. Prestressing strand perASTM A416 grade 7. 270 low relaxation. 7/32 wire per ASTM A510. 8. Mortar per ASTM C270 type M or S. © © © 8F20-OB% T 8F20-1B/110 1T 8F20-1B- © O I IN 0 i 6 IN on MONSOON NMI 6 #5REBAR MIN. ATTOP (1) REQ'D CLEAR ALTERNATE POWERS STEEL LINTEL d n d (1 4 4 .M.U. #5 REBAR AT TOP ° Q ° D 4' n O GROUT MIN. (1) RECI'D 1-1/2" CLEAR e G a c r J D Q C.M.U. 5 REBAR AT = u~i w - O BOTTOM OF � cn z w w 0 o `-*-BOTTOM LINTEL CAVITY U ❑¢ d O z 0 REINFORCING PROVIDED IN LINTEL ¢ ¢ C7 Co Z Z "6 o w v^� a = - u, D D Q L l 5 REBAR AT BOTTO AS INDICATED 7-5/8"ACTUAL 'NOMINAL WIDTH (VARIES) a o , LINTEL MINIMUM DEPTHS ARE CALLED OUT ON LINTEL PLAN. IF CONTRACTOR INSTALLS A DEEPER LINTEL THAN INDICATED ON THE PLAN, DOING THIS INCREASES THE STRENGTH OF THE LINTEL AND IS APPROVED WITHOUT ENGINEERING LETTER. IF A SMALLER LINTEL IS INSTALLED CONTACT E.O.R. FOR APPROVAL. (SEE LINTEL PLAN FOR SCHEDULE) 16 GAUGE POWERS STEEL BOXED LINTEL POWERS STEEL BOXED LINTEL NOTES (ALT.) ONLY IF NOTED ON LINTEL PLAN 1. Refer to manufacturer's specifications for installation. 2. Contractor to provide proper protection of lintel to prevent rusting Refer to manufacturer's specifications. 3. If lintel is scratched or damaged refer to Powers Steel for repair. 4. Lintel depth to match precast depth. One #5 Bar required at top see lintel plan/details for bottom steel required. 5. A bonding agent must be applied to the Steel Box lintels prior to applying the cementitiuos coating. See contractor specifications O O 4'-6" LL 4'-6" LL 6-10" LL SCALE: l4"=1'-0" 0 z o o Q CL Ln�, Z W cn 4--J w VO fv E 0 f ^ � MO /v, 2 I` 4 ✓ O M w �- E ® 0 0) Cl) m - 0 .o 0 N N LL c0 O f6 co N �Y 0-0 0d Q u7 O Q O 1 D. N C B D C TR *C1 / N � N ..`'V o 00 y o o `�,,W 'O co .M N N �'�'.Z r a) co 0 co ,lu7 LLB Q.a ids a� t� _ o a: -_ ��/� m C) O_ �.O To the best of the EngineJASYrii information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code 5th Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. O O Z cV O a� t--I 4-J O F>(n Q�raLn d N n Ln Q LO fl. n U 0000 Z Q Z § L(a Z I� J W � J oz �o 35 Wn za z� �F �¢C� O� 0 1--ZUO U Z 'M =owZ LLJ OU � _ J i-1 W N mz0 L� Y } O �y VT• J w z k M F- QJ -0 I A-'0 O J o U L11 J O w aYZO ® to XOOU o¢Wo°d fV —� UJ � a o w C) Z �o,.o LU ,�1 Ln =Q�Z J c� lJ J a w �ow0 Y F r��—{ z z LO Z a a �Z z O Q Z LU T_A d ��q V / Z SCALE : AS NOTED DATE ; 2/24/2014 TECH: ERAND VERSION NO. 10 SHEET NO. 8.0 NOTE: BORATE/ SENTRA CON SYSTEM APPLIED TO ALL FRAME MEMBERS WITHIN 24" A.F.F. 1) METHOD OF TREATMENT SHALL BE APPROVED BY THE GOVERNING JURISDICTION "LIQUID BORATE OR BOR-A-COR" PRODUCT METHODS MUST BE DETERMINED AT PERMIT STAGE. 2) PRESSURE TREATED LUMBER THAT HAS BEEN CUT OR DRILLED THAT EXPOSES UNTREATED PORTIONS OF WOOD ARE REQUIRED TO BE FIELD TREATED TO PREVENT INSECT INFESTATION. ATTENTION: CHEMICAL CHANGES IN PRESSURE TREATED WOODS AS OF DECEMBER 31ST, 2003, CHROMATED COPPER ARSENATE (CCA-C) WILL NO LONGER BE PRODUCED FOR RESIDENTIAL OR GENERAL CONSUMER USE. SEVERAL NEW PRESSURE TREATED WOOD ALTERNATIVES HAVE BEEN CREATED TO REPLACE CCA-C. MANY OF THE NEW PRESSURE TREATED WOODS USE CHEMICALS THAT ARE CORROSIVE TO STEEL. IT IS THE CONTRACTOR'S RESPONSIBILITY T0 VERIFY E FY THE TYPE OF WOOD TREATMENT AND TO SELECT APPROPRIATE CONNECTORS THAT RESIST CORROSION. FOR EXAMPLE, ACQ-C, ACQ-D, CBA-A, OR CA-B REQUIRE HOT -DIPPED GALVANIZED OR STAINLESS STEEL FASTENERS. DOT SODIUM BORATE (SBX) DOES NOT. REQUIRED SAFETY GLAZING IN HAZARDOUS LOCATIONS RE: FRC R308.4 R308.3 HUMAN IMPACT LOADS. INDIVIDUAL GLAZED AREAS INCLUDING GLASS MIRRORS IN HAZARDOUS LOCATIONS SUCH AS THOSE INDICATED AS DEFINED IN SECTION R308.4 SHALL PASS THE TEST REQUIREMENTS OF CPSC 16 CFR, PART 1201 CRITERIA FOR CATEGORY I OR CATEGORY II AS INDICATED IN TABLE R308.3 EXCEPTIONS: 1. POLISHED WIRED GLASS FOR USE IN FIRE DOORS AND OTHER FIRE RESISTANT LOCATIONS SHALL COMPANY WITH ANSI Z97.1 2. LOUVERED WINDOWS AND JALOUSIES SHALL COMPANY WITH SECTION R308.2 R308.4 HAZARDOUS LOCATIONS. THE FOLLOWING SHALL BE CONSIDERED SPECIFIC HAZARDOUS LOCATIONS FOR THE PURPOSE OF GLAZING: 1. GLAZING IN SWINGING DOORS EXCEPT JALOUSIES. 2. GLAZING IN FIXED AND SLIDING PANELS OF SLIDING DOOR ASSEMBLIES AND PANELS IN SLIDING AND BIFOLD CLOSET DOOR ASSEMBLIES. 3. GLAZING IN STORM DOORS. 4. GLAZING IN ALL UNFRAMED SWINGING DOORS. 5. GLAZING IN DOORS AND ENCLOSURES FOR HOT TUBS, WHIRLPOOLS, SAUNAS, STEAM ROOMS, BATHTUBS, AND SHOWERS. GLAZING IN ANY PART OF A BUILDING WALL ENCLOSING THESE COMPARTMENTS WHERE THE BOTTOM EXPOSED EDGE OF THE GLAZING IS LESS THAN 60 INCHES (1524MM) MEASURED VERTICALLY ABOVE ANY STANDING OR WALKING SURFACE. 6. GLAZING, IN AN INDIVIDUAL FIXED OR OPERABLE PANEL ADJACENT TO A DOOR WHERE THE NEAREST VERTICAL EDGE IS WITHIN A 24-INCH(610MM) ARC OF THE DOOR IN A CLOSED POSITION AND WHOSE BOTTOM EDGE IS LESS THAN 60 INCHES (1524MM) ABOVE THE FLOOR OR WALKING SURFACE. 7. GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL, OTHER THAN THOSE LOCATIONS DESCRIBED IN ITEMS 5 AND 6 ABOVE, THAT MEETS ALL OF THE FOLLOWING CONDITIONS: 7.1 EXPOSED AREA OF AN INDIVIDUAL PANE GREATER THAN 9 SQUARE FEET (0.836 M2). 7.2 BOTTOM EDGE LESS THAN 18 INCHES (457 MM) ABOVE THE FLOOR, 7.3 TOP EDGE GREATER THAN 36 INCHES (914 MM) ABOVE THE FLOOR. 7.4 ONE OR MORE WALKING SURFACES WITHIN 36 INCHES (914 MM) HORIZONTALLY OF THE GLAZING. 8. ALL GLAZING IN RAILINGS REGARDLESS OF AN AREA OR HEIGHT ABOVE WALKING SURFACE. INCLUDED ARE STRUCTURAL BALUSTER PANELS AND NONSTRUCTURAL IN FILL -PANELS. 9. GLAZING IN WALLS AND FENCES ENCLOSING INDOOR AND OUTDOOR SWIMMING POOLS, HOT TUBS AND SPAS WHERE THE BOTTOM EDGE OF THE GLAZING IS LESS THAN 60 INCHES (1524 MM) ABOVE A WALKING SURFACE AND WITHIN 60 INCHES (1524 MM) HORIZONTALLY OF THE WATER'S EDGE. THIS SHALL APPLY TO SINGLE GLAZING AND ALL PANES IN MULTIPLE GLAZING. 10. GLAZING ADJACENT TO STAIRWAYS, LANDINGS, AND RAMPS WITHIN 36 INCHES (914 MM) HORIZONTALLY OF A WALKING SURFACE WHEN THE EXPOSED SURFACE OF THE GLASS IS LESS THAN 60 INCHES (1524 MM) ABOVE THE PLANE OF THE ADJACENT WALKING SURFACE. 11. GLAZING ADJACENT TO STAIRWAYS WITHIN 60 INCHES (1524 MM) HORIZONTALLY OF THE BOTTOM TREAD OF A STAIRWAY IN ANY DIRECTION WHEN THE EXPOSED SURFACE OF THE GLASS IS LESS THAN 60 INCHES (1524 MM) ABOVE THE NOSE OF THE TREAD. EXCEPTION: THE FOLLOWING PRODUCTS, MATERIALS AND USES ARE EXEMPT FROM THE ABOVE HAZARDOUS LOCATIONS: 1. OPENINGS IN DOORS THROUGH WHICH A 3-INCH(76 MM) SPHERE IS UNABLE TO PASS. 2. DECORATIVE GLASS IN ITEMS 1, 6 OR 7. 3. GLAZING IN SECTION R308.4, ITEM 6, WHEN THERE IS AN INTERVENING WALL OR OTHER PERMANENT BARRIER BETWEEN THE DOOR AND THE GLAZING. 4. GLAZING IN SECTION R 308.4 ITEM 6 IN WALLS PERPENDICULAR TO THE PLANEOF THE DOOR IN A L CLOSED POSITION OR WHERE ACCESS THROUGH THE DOOR IS TO A CLOSET OR STORAGE AREA 3 FEET (914 MM) OR LESS IN DEPTH. GLAZING IN THESE APPLICATIONS SHALL COMPANY WITH SECTION R308.4, ITEM 7. 5. GLAZING IN SECTION R308.4, ITEMS 7 AND 10, WHEN A PROTECTIVE BAR IS INSTALLED ON THESE ACCESSIBLE SIDE(S) OF THE GLAZING 36 INCHES ± 2 INCHES (914 ± MM 51 MM) ABOVE THE FLOOR. THE BAR SHALL BE CAPABLE OF WITHSTANDING A HORIZONTAL LOAD OF 50 POUNDS PER LINEAR FOOT KG/M) WITHOUT CONTACTING THE GLASS AND BE A MINIMUM OF 1 INCHES (38 MM) IN HEIGHT. 6. OUTBOARD PANES IN INSULATING GLASS UNITS AND OTHER MULTIPLE GLAZED PANELS IN SECTION R308.4, ITEM 7, WHEN THE BOTTOM EDGE OF THE GLASS IS 25 FEET (7620 MM) OR MORE ABOVE GRADE, A ROOF, WALKING SURFACES, OR OTHER HORIZONTAL [WITHIN 45 DEGREES (0.79 RAD) OF HORIZONTAL] SURFACE ADJACENT TO THE GLASS EXTERIOR, 7. LOUVERED WINDOWS AND JALOUSIES COMPLYING WITH THE REQUIREMENTS OF SECTION R308.2. 8. MIRRORS AND OTHER GLASS PANELS MOUNTED OR HUNG ON A SURFACE THAT PROVIDES A CONTINUOUS BACKING SUPPORT. 9. SAFETY GLAZING IN SECTION R308.4, ITEMS 10 AND 11 IS NOT REQUIRED WHERE: 9.1 THE SIDE OF STAIRWAY, LANDING OR RAMP HAS A GUARDRAIL OR HANDRAIL, INCLUDING BALUSTERS OR IN -FILL PANELS, COMPLYING WITH THE PREVISIONS OF SECTION 1012 AND 1607.7 OF THE FLORIDA BUILDING CODE, BUILDING; AND 9.2 THE PLANE OF THE GLASS IS GREATER THEN 18 INCHES (457 MM) FROM THE RAILING. 1. SPECIFICATIONS 1. 1. CONSTRUCTION: 1. 1. 1. ACI 318-11 BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE 1. 1. 2.. ACI 530-11, ASCE 5/TMS 402-11 & ACI 530.1-11, ASCE 6/TMS 602-11 SPECIFICATIONS FOR MASONRY STRUCTURES. 1. 1. 3. ASTM C270-07a, C90-06b & C91-05 SPECIFICATIONS FOR MASONRY STRUCTURES 1.1.4. NATIONAL DESIGN SPECIFICATIONS (NDS) FOR WOOD CONSTRUCTION, 2012 EDITION, AND ALL ACCOMPANYING SUPPLEMENTS. 1.1.5. FLORIDA RESIDENTIAL CODE (FRC), FLORIDA BUILDING CODE (FBC) 5th ed, (2014) 1.1.6. "MANUAL OF STEEL CONSTRUCTION, ALLOWABLE STRESS DESIGN", BY THE AMERICAN INSTITUTE OF STEEL CONSTRUCTION, (AISC) 13TH EDITION. 1. 1.7. "DESIGN SPECIFICATION FOR LIGHT METAL PLATE CONNECTED WOOD TRUSSES" BY THE TRUSS PLATE INSTITUTE TRI1-02. 1.2. DESIGN: 1.2.1, ACI 301-11 BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE 1.2.2. ACI 530-11, ASCE 5/TMS 402-11 & ACI 530.1-11, ASCE 6/TMS 602-11 SPECIFICATIONS FOR MASONRY STRUCTURES. 1.2.3. ASTM C270-07a, C90-06b & C91-05 SPECIFICATIONS FOR MASONRY STRUCTURES 1,2.4. NATIONAL DESIGN SPECIFICATIONS (NDS) FOR WOOD CONSTRUCTION, 2012 EDITION, AND ALL ACCOMPANYING SUPPLEMENTS. 1.2.5. PLYWOOD DESIGN SPECIFICATIONS (APA) 1.2.6. FLORIDA BUILDING CODE (FBC) 5th ad. (2014) AND FLORIDA BUILDING CODE 5th ed. RESIDENTIAL (FBCR) 1.3. SHOP DRAWINGS: 1.3.1. THERE SHALL NOT BE ANY DEVIATIONS FROM THESE DESIGN PLANS BY OTHERS DURING THE PREPARATION OF SHOP DRAWINGS WITHOUT WRITTEN APPROVAL FROM THE ENGINEER OF RECORD. 1.3.2. ALL SHOP DRAWINGS ARE TO BE SUBMITTED TO THE ENGINEER OF RECORD PRIOR TO THE COMMENCEMENT OF CONSTRUCTION. 1.3.3. ALL ROOF AND FLOOR TRUSS SHOP DRAWINGS ARE TO BE SIGNED AND SEALED BY A FLA, REG. PE. AND SHALL INCLUDE: DRAWINGS AND CALCULATIONS REACTIONS AND BEARING POINTS BRACING REQUIREMENTS, CONNECTIONS TO Q AND SUPPORTING TRUSS MEMBERS. 2. DESIGN LOADS 2.1. DEAD LOADS: 2. 1. 1. UNIT WEIGHT OF SOIL, COMPACTED: 120 PCF 2.1.2. WEIGHT NIT F REINFORCED CONCRETE: U 0 ORCED CONCRE 150 PCF 2.1.3. UNIT WEIGHT OF 8" C.M.U. BLOCK: 55 PSF 2.1.4. 1ST FLOOR SUPERIMPOSED LOAD: 20 PSF 2.1.5. UNIT WEIGHT OF 2x4 PARTITION WALLS: 11 PSF 2.1.6. UNIT WEIGHT OF 2x6 BEARING WALLS: 12 PSF 2,1.7. BALCONIES & DECKS: 15 PSF 2. 1.8. TILE ROOF TOP CHORD : 15 PSF BOTTOM CHORD: 10 PSF 2.1.9. SHINGLE ROOF TOP CHORD : 7 PSF BOTTOM CHORD: 10PSF 2. 1. 10, FLOOR TRUSSES 15 2.2. LIVE LOADS: 2.2.1. SIDEWALK AND DRIVEWAY LOAD: 250 PSF 2.2.2. GARAGE LOADS : 40 PSF 2.2.3, PARTITIONED ROOMS: 40 PSF 2.2.4. BALCONY AND DECKS: 60 PSF-UNDER 100 sq. ft. 2.2.5. STAIRWAYS AND LANDINGS: 40 PSF 2. 2, 6. SLEEPING ROOMS: 30 PSF 2.2.7. FLOOR TRUSS TOP CHORD MINIMUM: 40 PSF 2.2.8. ROOF TRUSS TOP CHORD MINIMUM: 20 PSF BOTTOM CHORD (ATTIC W/O LIMITED STORAGE) : 10 PSF (NON -CONCURRENT) BOTTOM CHORD (ATTIC W/ LIMITED STORAGE) : 20 PSF 2.3. RAILING LOADS: 2.3.1. ALL RAILING AND GUARD RAIL SYSTEM'S ARE TO BE DESIGNED TO WITHSTAND A CONCENTRATED LOAD OF 200 POUNDS APPLIED AT ANY POINT AND IN ANY DIRECTION ON THE RAILING. 2.3.2. ALL RAILING AND GUARD RAIL SYSTEM'S ARE TO BE DESIGNED TO WITHSTAND A HORIZONTAL LOAD OF 50 PLF ON THE GUARDRAIL AND A SIMULTANEOUS LOAD OF 100 PLF APPLIED VERTICALLY DOWNWARD AT THE TOP OF THE GUARDRAIL 2.3.3. GUARDRAIL SYSTEM SHALL BE DESIGNED TO WITHSTAND 2001b CONCENTRATED HORIZONTAL LOAD APPLIED ON 1 SQ. FT. AT ANY POINT IN THE SYSTEM. 2.3.4. 2.3.1., 2.3.2 & 23.3. ARE NOT REQUIRED TO BE APPLIED SIMULTANEOUSLY, BUT EACH SHALL BE APPLIED TO PRODUCE THE MAXIMUM STRESSES IN THE MEMBER COMPONENTS. 2.4. WIND LOADS: 2.4.1. WIND DESIGN TO BE CONDUCTED IN ACCORDANCE WITH SECT. R301.2 OF THE FBC 5th ed. (2014), AND CONDUCTED BASED ON A140 MPH 3 SECOND GUST, EXPOSURE "C", IMPORTANCE FACTOR "I" = 1.0. ENCLOSED BUILDING 2.4.2. NET UPLIFT DEAD LOADS -10 PSF SHINGLE, 15 PSF TILE 2.4.3. WIND LOAD DETERMINATION BASED ON ASCE 7-10 2.5. DEFLECTIONS: 2. 6. 1. FLOOR TRUSSES SHALL LIMIT DEFLECTION TO U480TIMES THE SPAN FOR LIVE LOADS AND U240 TIMES THE SPAN FOR TOTAL LOAD. 3. DESIGN METHOD 3.1. LOAD FACTOR DESIGN: 3. 1. 1. THE LOAD FACTOR DESIGN METHOD WAS USED TO DESIGN: CAST -IN -PLACE CONCRETE SLABS AND FOOTINGS 3.2. SERVICE LOAD DESIGN: 3.2.1. THE SERVICE LOAD DESIGN METHOD WAS USED TO DESIGN: MASONRY WALLS AND LINTELS INTERIOR AND EXTERIOR WOOD FRAMING AND SHEATHING STAIRS AND FLOOR FRAMING ROOF FRAMING, SHEATHING AND UPLIFT 3.3. LOAD COMBINATIONS FOR LRFD DESIGNS: 3.3.1. THE FOLLOWING LOAD COMBINATIONS WERE DESIGNED FOR: TOTAL DL + FLOOR LL + ROOF LL TOTAL DL + FLOOR LL + WL TOTAL DL + WL 3.3.2. ALL ROOF AND FLOOR TRUSSES SHALL BE DESIGNED TO RESIST THE WORST LOAD COMBINATION RESULTING IN THE MAXIMUM STRESSES PLACED ON THAT COMPONENT, BOTH PARTIAL, FULL, AND ALTERNATING SPAN LOADING ARE TO BE CONSIDERED. 3.4. DESIGN ASSUMPTIONS: 3.4.1. ALL FOUNDATIONS ARE CENTERED UNDER SUPPORTED COLUMNS AND WALLS UNLESS SHOWN OTHERWISE IN THE DESIGN PLANS. 4• MATERIALS 4.1. REINFORCING STEEL: 4. 1. 1. REINFORCING STEEL SHALL BE ASTM A615 / A185M-04A MIN. GRADE 40, fy = 40 Ksi 4.1.2. LAP SPLICE SHALL BE AS FOLLOWS: #5 BAR 25", #4 BAR 20", #3 BAR 20". 4.1.3. ALL DIMENSIONS PERTAINING TO THE LOCATION OF REINFORCING ARE TO THE CENTERLINE OF EACH BAR EXCEPT WHERE THE COVER DIMENSION IS SHOWN TO THE FACE OF THE CONCRETE. 4.1.4. REINFORCING DETAIL DIMENSIONS ARE OUT TO OUT OF BARS. 4.1.5. REINFORCING MECHANICAL COUPLERS ARE TO DEVELOP 125 % OF THE REQUIRED YIELD STRENGTH OF THE BAR AND ARE TO BE APPROVED BY THE ENGINEER OF RECORD. 4.1.6. DESIGN COVER REQUIREMENTS: C-1-P CONCRETE FORMED AGAINST EARTH: 3" C-1-P CONCRETE EXPOSED TO EXTERIOR: C-1-P CONCRETE NOT EXPOSED: 1 /„ GROUT FILLED MASONRY: �" 4. 1. 7. WELDED WIRE FABRIC (WWF): ASTM A-185 /A 185M-07 4.1.8. DETAIL REINFORCEMENT IN ACCORDANCE WITH ACI 318-11 (STRUCTURAL CONCRETE) ACI 530-11 (MASONRY STRUCTURES) 4.2. CONCRETE: 4.2.1, MODULES OF CONCRETE TYPE MIN. 28 DAY ELASTICITY DESIGN (fc) DESIGN (E) C-I-P CONCRETE (NORMAL WEIGHT) 2,500 Psi 2,850 Ksi C-I-P CONCRETE (NORMAL WEIGHT) HERNANDO CO. ONLY 3,000 Psi 3,122 Ksi C-I-P GROUT 3,000 Psi 3,122 Ksi 4.2.2. CONCRETE SHALL CONSIST OF 1" MAXIMUM AGGREGATE CONCRETE MIX WITH SLUMP BETWEEN 6" AND 7" AT TIME OF PLACEMENT. SEE SPECIFICATIONS FOR ADDITIONAL CRITERIA. 4.2.3. GROUT SHALL CONSIST OF PEA ROCK (3/8" MAXIMUM AGGREGATE) CONCRETE MIX WITH SLUMP BETWEEN 8" AND 10" AT TIME OF PLACEMENT. SEE SPECIFICATIONS FOR ADDITIONAL CRITERIA. 4.2.4. CONSTRUCTION JOINTS WILL BE PERMITTED 4.2.5. METHOD OF CONCRETE FORMING, PLACEMENT AND CURING SHALL BE CONDUCTED IN ACCORDANCE WITH THE SPECIFICATIONS AS STATED. 4.2.6. EARTH SUPPORTED SLABS (EXCLUDING EXTERIOR WALKWAYS & DRIVEWAYS) : 3 1/2" MIN. THICKNESS W/ MIN. REINFORCEMENT OF 6.0 x 6.0 W/ 1.4 x 1.4 WWF @ MID -DEPTH OF SLAB. FIBER MESH PER DESIGN MIX MAY BE USED I.L.O. WWF @ CONTRACTORS DISCRETION. 4.2.7. CONCRETE PLACEMENT PRACTICES SHALL BE IN ACCORDANCE W/ ALL ACI- MCP 2011 STANDARDS. 4.3. CONCRETE MASONRY: 4.3.1. FILLED CELLS W/ (1) #5 BAR SHALL BE LOCATED PER PLAN. 4.3.2. LOAD BEARING CONCRETE MASONRY BLOCK SHALL BE ASTM C90-0601, TYPE II NON -MOISTURE CONTROLLED. 4.3.3. ALL CELLS & CAVITIES BELOW GRADE WILL BE FILLED W/ CONCRETE IN ALL STEM WALLS. 4.3.4. THE AGGREGATE STRENGTH OF THE BLOCK AND MORTAR SHALL BE F'm = 1,500 PSI MINIMUM. 4.3.5. METHOD OF CONCRETE MASONRY PLACEMENT AND CONSTRUCTION SHALL BE CONDUCTED IN ACCORDANCE WITH THE SPECIFICATIONS AS STATED. 4.3.6. MORTAR SHALL BE ASTM C270 TYPE "S" FOR ALL MASONRY CONSTRUCTION. 4.4. STRUCTURAL LUMBER : 4.4. 1.1. INTERIOR LOAD BEARING WALLS SPF #2, fb =1,312 PSI, E =1,400 KSI ALL EXTERIOR FRAMING SPF #2, fb = 1,312 PSI, E =1,400 KSI 4.4. 1.2. ALL FRAME WALLS TO BE CONSTRUCTED USING SPF #2, STUD QUALITY OR BETTER 4.4.2. ALL PLYWOOD USED FOR EXTERIOR APPLICATIONS SHALL BE APA RATED STRUCTURAL SHEATHING 15/32" EXP 1 OR 7/16" STRUCTURAL 1, U.N.O. 4. 4.3. ALL PLYWOOD USED FOR INTERIOR APPLICATIONS SUCH AS SUB FLOORING 0 NG AND SHEAR WALLS SHALL BE APA RATED SHEATHING EXP 1 U.N.O. 4.4.4. IF OSB BOARD IS TO BE USED IN PLACE OF PLYWOOD IS TO HAVE SIMILAR OR GREATER SECTION PROPERTIES. 4.4.5. ONLY STRUCTURAL LUMBER TO BE USED FOR AN EXTERIOR APPLICATION. WOOD IN CONTAGT WITH CONCRETE IS TO RECEIVE A STANDARD GRADE PRESSURE TREATING. 4.4, 6. WHEN PRE ENGINEERED TRUSSES ARE CALLED FOR ON THE PLANS THE MANUFACTURER IS TO SUBMIT SHOP DRAWINGS TO THE ENGINEER OF RECORD. 4.4.7. DESIGN, FABRICATE AND ERECT WOOD TRUSSES IN ACCORDANCE WITH THE "DESIGN SPECIFICATION FOR LIGHT METAL PLATE CONNECTED WOOD TRUSSES" BY THE ANSIITPI 1-2007, BCSI 4.4. 8. UNTREATED WOOD SHALL NOT BE IN DIRECT CONTACT WITH CONCRETE. SEAT PLATES SHALL BE PROVIDED AT BEARING LOCATIONS WITHOUT WOODEN TOP PLATES. 4.4.9. ALL EXTERIOR FRAME WALLS SHALL BE STUCCO FINISH- 7/8" STUCCO FINISH PER ASTM C. 926, APPLY 3 LAYERS Wl TOTAL THICKNESS 7/8" OVER METAL LATH. FIRST 2 LAYERS 3/8" THICK EACH. 3RD LAYER 1/8" THICK 4.4.10. INSTALLATION OF EXTERIOR LATHING & FRAMING SHALL COMPLY TO ASTM C 1063 PER FLORIDA CODE R706.6.1 4.5. FASTENERS AND TIE DOWNS: 4.5.1. FASTENERS AND TIE DOWNS SHALL CONSIST OF BUT ARE NOT LIMITED TO: SHAPES, ANGLES, CHANNELS: ASTM A36/36M 05 Fy = 36 Ksi ROUND METAL PIPE: ASTM A53, GRADE B Fy = 35 Ksi SQUARE METAL TUBING: ASTM A500, GRADE B Fy = 46Ksi HIGH STRENGTH BOLTS: ASTM A325 MACHINE BOLTS: GALVANIZED ASTM A307 4.5.2. SHEET METAL ACCESSORIES SHALL CONFORM TO: Fy = 33KsiWITH G90 GALVANIZED COATING IN ACCORDANCE WITH ASTM A525-87. 4.5.3. NAILS SHALL CONSIST OF: COMMON WIRE NAILS WITH MINIMUM DIAMETER AS FOLLOWS: 8d = 0.131", 10d = 0.148", 12d = 0.148", 16d = 0.162". 4.5.4. ALL FASTENERS AND TIE DOWNS EMBEDDED IN CONCRETE OR USED IN AN EXTERIOR APPLICATION ARE TO RECEIVE AN ANTI -CORROSIVE COATING BY MANUFACTURER PRIOR TO INSTALLATION. 4.5.5. ALL FASTENERS AND TIE DOWNS ARE TO PROVIDE THE UPLIFT CAPACITY CALLED FOR IN THE PLANS ARE A MINIMUM. 4.5.6. ALL FASTENER TIE DOWNS, BEAM HANGERS, JOIST HANGERS, AND FLOOR TRUSS STRAPPING ARE TO BE INSTALLED IN ACCORDANCE WITH THE PLANS AND SPECIFICATIONS. 4.5.7, CONCRETE EMBEDDED V BOLTS USED FOR UPLIFT ARE TO BE WET SET PRIOR TO INITIAL SET OF THE CONCRETE, SPACING AND ALIGNMENT ARE TO BE IN ACCORDANCE WITH THE DESIGN PLANS U.N.O. ALTERNATES TO'°J" BOLTS ARE NOTED ON PLANS. S 4.5.8. CONCRETE EMBEDDED TIE DOWNS USED FOR TRUSS AND WALL UPLIFT ARE TO BE PLACED AROUND EMBEDDED REINFORCING PRIOR TO OR WHILE PLACING GROUT. 4.6. MICRO -LAM LUMBER: 4.6.1. MICRO -LAM STRESS GRADES SHALL PROVIDE THE FOLLOWING MINIMUM PROPERTIES: E = 2,000,000 PSI Fb = 2,950 PSI Ft = 1,850 PSI Fc = 500 PSI (PERPENDICULAR) Fc = 2,700 (PARALLEL) 4.7. STEEL: Fv= 285PSI 4.7.1. INSTALLATION OF ALL STEEL TO BE PERFORMED BY AN EXPERIENCED, QUALIFIED STEEL ERECTOR. 4.7.2. FABRICATE AND ERECT ALL STRUCTURAL STEEL IN ACCORDANCE WITH A.I.S.C. "SPECIFICATION FOR THE DESIGN, FABRICATION, AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS". 4,7.3. STRUCTURAL STEEL: ASTM A36136M 05. 4.7.4. STEEL TUBING: ASTM A500, GRADE B. 4.7.5. WELDED CONNECTIONS: E70XX ELECTRODES, MINIMUM SIZE FILLET WELDS 3/16", AWS CERTIFIED WELDERS. CERTIFICATION PAPERS TO BE SUBMITTED UPON REQUEST, 4.7.6. WHERE STEEL BEAMS ARE CONTINUOUS OVER COLUMNS, PROVIDE WEB STIFFENER PLATES ON EACH SIDE OF THE WEB, OF A THICKNESS EQUAL TO BEAM FLANGE THICKNESS, LOCATED AT THE CENTER LINE OF THE TUBE COLUMN. 4.7.7. THE STEEL FRAME IS "NON -SELF SUPPORTING". ADEQUATE TEMPORARY SUPPORT SHALL BE PROVIDED BY THE CONTRACTOR UNTIL REQUIRED CONNECTIONS OR 4.8. SOIL: ELEMENTS ARE IN PLACE. 4, 8. 1. MINIMUM SOIL BEARING PRESSURE CAPACITY OF 2000 PSF. FOUNDATIONS HAVE BEEN DESIGNED WITH THE MIN. CAPACITY OF 2000 PSF 4.8.2. ALL SOIL IS TO BE CLEAN & POISONED FOR TERMITES PER FBC 5th ed. (2014), RESIDENTIAL SECTION R318. 4.8.3. SOIL IS TO BE COMPACTED TO 95% MODIFIED PROCTOR AS DEFINED BY ASTM D 1557-02E01 TERMITE PROTECTION - CONTRACTOR TO USE (1) OF THE TREATMENTS BELOW Borate / Boracore treated lumber Soil Chemical Barrier Method Other treatment - Must specify proposed method and submit documentation, which substantiates the proposed method, is an approved termite protection system or method. OR CHEMICAL SOIL TERMITE TREATMENT IS USED 1. FRC R318.1- "A permanent siggn which identifies the termite treatment provider for be and need re -inspection andtreatment contract renewal shall provided. The sign shall be posted near the water heater or electric panel" 2. Condensate and roof downspouts shall discharge at least V-0" away from the building side walls. 3. Irrigation/sprinkler systems including all risers and spray heads shall not be installed within V-0" of the building side wall. 4. FRC R318.7- To provide for inspection for termite infestation, between finalearth inches. wall covering andgrade shall not be less than 6 Exception: Paint or decorative cementitious finish less than 5/8" thick adhered directly to the foundation wall. 5. FRC R318.1.1 - Initial treatment shall be done after all excavation and backfill is complete. 6, FRC R318.1.2 - Soil disturbed after the initial treatment shall be retreated including spaces boxed or formed. 7. FRC R318.1.3 - Boxed areas in concrete floors for subsequent installation of traps etc., shall be made with permanent metal or plastic forms. Permanent forms must be of a size and depth that will eliminate the disturbance of soil after the initial treatment, 8. FRC R318.1.4 - Minimum 6 mil vapor retarder must be installed to protect against rainfall dilution. If rainfall occurs before vapor retarder placement, retreatment is required. 9. FRC R318.1.5 - C n rete over our nd mortar along the foundation perimeter must be removed �iecfore exterloor soil treatment. 10. FRC R318.1.6 - Soil treatment must be applied under all exterior concrete or grade within V-0" of the structure sidewalls. 11. FRC R318.1.6 - An exterior vertical chemical barrier must be installed after is including landscaping irrigation. Any construction complete, and soil disturbed after the vertical barrier is applied, shall be retreated, 12. FRC R318.1 - All buildings are required to have pre -construction treatment. 13. FRC R318.1 - A certificate of compliance must be issued to the building department by a licensed pest control company before a certificate of occupancy will be issued. The certificate of compliance shall state: "The building has received a complete treatment for the prevention of subterranean termites. The treatment is in accordance with the rules and laws of the Florida Department of Agriculture and Consumer Services". 14. FRC R318.6 - After all work is completed, loose wood and fill must be removed from below and within V-0" of the building. This includes all grade stakes, tub trap boxes, forms, shoring or other cellulose containing material. WORST CASE DESIGN PRESSURE TABLE BUILDING DATA WIND SPEED (ULTIMATE) 140 MPH WIND SPEED (ALLOWABLE) 108 MPH WIND EXPOSURE -- "C" (FRC R301) INTERNAL PRESSURE COEFFICIENT= 0.18 ENCLOSED BLDG) BUILDING CATEGORY = II DESIGN WIND PRESSURE: (COMPONENT AND CLADDING) WORST CASE (10 SF - END ZONE) # END ZONE IS ONLY WITHIN 5'-0" OF ALL EXTERIOR BUILDING CORNERS WINDOWS AND DOORS 140 MPH + 29.7 PSF / -39.6 PSF (END) U.N.O. + 29.7 PSF / -32.2 PSF (INTERIOR) U.N.O. CONSTRUCTION GARAGE DOORS (V = 140 MPH) TYPE: 5B SINGLE 90 +26.3 PSF / -29.8 PSF DOUBLE 160 +25.2 PSF / -28.1 PSF NOTE: THE WIND PRESSURES LISTED ABOVE ARE ALLOWABLE PRESSURES. NOTE: IT IS THE CONTRACTORS RESPONSIBILITY TO REVIEW AL L DRAWINGS BEFORE CONSTRUCTION BEGINS. FLORIDA DESIGN SOLUTIONS, INC. IS RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF THIS PROJECT ONLY. ANY DISCREPANCY BETWEEN FIELD CONDITIONS, OTHER DESIGN PROFESSIONALS' SHOP DRAWINGS, CONTRACTORS' BUILDING METHODS, AND THESE SIGNED AND SEALED DRAWINGS MUST BE BROUGHT TO THE ATTENTION OF FLORIDA DESIGN SOLUTIONS, INC. PRIOR TO THE COMMENCEMENT OF CONSTRUCTION. NOTE: GYPSUM BOARD MAY BE INSTALLED USING GWB54 NAILS TO SET IN PLACE. FIELD FASTENING SHOULD BE TYPE "W" 1 4" DRYWALL SCREWS AT 12" O.C. FOR CEILINGS AND 1 $" DRYWALL SCREWS AT 12" O.C. FOR WALLS. ALL ENDS AND EDGES OF WALLBAORD SHALL OCCUR OVER AND BE SCREWED TO SUPPORTS. MAXIMUM SCREW SPACING AT ENDS (EDGES IN VERTICAL APPLICATION) SHALL BE 6" O.C. AT EACH SUPPORT. MINIMUM SCREW / NAIL DISTANCEFROM EDGE SHALL BE /". THIS SHALL APPLY TO BOTH CEILING AND WALL INSTALLATION. DRYWALL SHIMS SHALL BE USED ONLY WHERE NECESSARY. OPENINGS CUT FOR OUTLETS, SWITCHES, ETC, SHALL BE OF A TOLERANCE THAT CAN BE COVERED ADEQUATELY WITH NORMAL SWITCH PLATES AND COVERS WITHOUT ADDITIONAL TAPING OR CAULKING. DRYWALL SHALL NOT BE INSTALLED WITHOUT PROPER BACKING. NOTE: ALL HEADERS, BEAMS, ETC ARE TO BE SYP #2 OR BETTER AND OR MICROLAM AS INDICATED ON THE DRAWINGS AND CAN NOT BE REVISED. 0U) �o Z Q J 0 I�n In ,, (D crs w Q 0 LU V) 0� E 0 r o 0 LU N M 0 N M �- E ® o MIi't' N a ch O .o 0 N a) -:5c00 a)Q- a) �Y o LO ov Q 0) ¢ o Do nce Dc It . CV CS) `� CV a co Co 0 o Z WoM N N Z �M J ' J r �O LL O � N LLL 0 a ¢ w,j�� mp?o `V N Q o O m m L. p m' l e 0O a �o_. Q To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code 5th Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. O O Z 0 � N O >()MO Q j 0 Lr _O Ln u- CL 13� U OL 00 Q E� Z WJ Ot,G oZ 0 W� zQa <¢ Zoo: 0 �zUo U Z Z Q _ Z Z C)0 w a w C o J i-1 UU � N W W O i.. U) LU l- o Z Z /1 0) F Q U �r O J 0 z C: M 1 Q S o p U _ (� I-- JZ o "- J v r XOt� F- U 2 m 5 d a R oaoa w L z Q Q QgFwo Z Woo W L0 a�oz ¢LLB J Q Z oWo W Z ¢�z T--q Ln Z aZ m Q J = z �o aZ X ,-, a to SCALE : AS NOTED DATE : 2/24/2014 TECH: ERAND VERSION NO 10 o SHEET NO. SN t� ROOF DIAPHRAGM NAILING SCHEDULE RIDGE LINE + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + o + + + + + + + + + + + + + + + + + + + + + + + + + + + � + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + -0" (TYP.) 6'-0" + + + 6-4' + + + + + + +++ + + + + +++ + + + + + + +++ +++ + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + o + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + ++ +++ ++++++++ + 15/32" CDX PLYWOOD OR 7116" OSB `RIDGE LINE 140 MPH (ult)3 SECOND GUST EXPOSURE "C" WIND ZONE 140 MPH (ult) 3 SECOND GUST EXPOSURE "C" WIND ZONE 8d RING SHANK NAILS @ 6" O.C. & 8d RING SHANK NAILS @ 6" O.C. EDGES & + + + + + 4" O.C. @ GABLE END WALL OR GABLE TRUSS 8d RING SHANK NAILS @ 6" O.C. INTERMEDIATE 0.113 INCH NOMINAL SHANK DIAMETER 0.113 INCH NOMINAL SHANK DIAMETER RING DIAMETER OF 0.012 OVER SHANK DIAMETER RING DIAMETER OF 0.012 OVER SHANK DIAMETER 16 TO 20 RINGS PER INCH 16 TO 20 RINGS PER INCH 0.280 INCH FULL ROUND HEAD DIAMETER 0.280 INCH FULL ROUND HEAD DIAMETER 2 INCH NAIL LENGTH 2 INCH NAIL LENGTH NOTE: * FOR 8d RING SHANK NAILS 0.113x 2x 3/8" RING SHANK COIL GUN NAILS MAY BE USED 1) SEE STRUCTURAL NOTES FOR SHEATHING SPECIFICATIONS AND WIND SPEED. 2) END JOINTS OF THE ROOF SHEATHING SHALL BE STAGGERED AND OCCUR OVER FRAMING MEMBER. 3) SCHEDULE ASSUMES SHEATHING IS FASTENED DIRECTLY TO SOUTHERN YELLOW PINE OR DOUGLAS FIR OR BETTER. IF ROOF FRAMING CONSISTS OF A LESSER GRADE OF LUMBER, CONTRACTOR MUST CONTACT ENGINEER OF RECORD FOR ALTERNATE NAILING PATTERN. Backer and Filler Block Dimensions BCI®Joist Backer Block Thickness Filler Block Thickness Series 3/4" 5000s 1.8/1.7 p nel wood panels Two 3/4" wood panels or 2 x 1-1 /8" or two 1/2" 6000s 1.8/1.7 wood panels 2 x — + 5/8" or 3/4" wood panel 1-1 /8" or two 1/2" 6500s 1.8/1.7 wood panels 2 x — + 518" or 3/4" wood panel 1-1/8" or two 1/2" 602.0 wood panels 2 x — + 5/8" or 3/4" wood panel 902.0 2 x — lumber Double 2 x — lumber DOUBLE JOIST CONSTRUCTION (Not required if both loaded equally from above) k Filler blocking x / 1/8" gap k / / FILL CELL STD. 90° HOOK BOND BEAM w ..... .... ... ...... ¢ STD. 90' CONT. #5 CONT. #5 HOOK BAR BAR #5 CONT. FROM FOUNDATION LTO BOND BEAM v BOND BEAM STEP SCALE: N.T.S. 2nd FLOOR INTERIOR/EXT WALL SEE PLAN FOR MORE INFO CONT. BASE PLATE BEARING COLUMN SEE PLAN FOR REQ'D PLYWOOD FLOOR COLUMN AND SHEATHING PER PLAN CONNECTION TJI TO BE CUT TO ALLOW FOR BLOCKINGITJI ~MASONRY WALL OR INTERIOR BRG. WALL TJI PER PLAN OTHERWISE SOLID BLOCKING TO MATCH Solid block all posts from # OF 2nd FLOOR above to bearing below. STUDS SECTION @ INT. BRG. WALL N.T.S. 1/8" min.) Small gap 2" min. 2" max. 4" max. i� Clinch nails when possible 1) Support back of web during nailing to prevent damage to web -flange connection. 2) Block solid between joists for full length of span. Tight fit 3) Leave 1/8" gap between top of filler blocking and bottom of top flange. 4) Place joists together and nail from each side with 2 rows of 10d nails 2x4/Plywood/OSB web stiffener 4" max. 2x_: CONTRACTOR TO PROVIDE 2x TO FILL THE HEIGHT at 12" o.c., clinched when possible. Stagger rows from opposite required when indicated or - Hangers with side nailing. OF THE JOIST ASA REQUIRED LEAVING %" GAP @ TOP sides by 6". - Hangers with sides not containing t. WEB STIFFENER DOUBLE JOIST CONNECTION topflanguthe ofcuts. - Birdsmouth cuts. N.T.S. Under 2nd floor column w/ loads N.T.S. SQUASH BLOCKS AT INTERIOR BEARING Vertical load transfer =1900 plf max along load bearing wall. Load bearing wall must stack *Non -stacking walls over squash=20 blocks and require additional wall or beam below.* consideration. Check local building code for appropriate ;V 1/16" details in One 10d box areas=20 of high or-20 sinker lateral load. nail each side 1 0'-0" at bearing. TANK -LESS W/H CORNER OF HOME H C G GARAGE SIDE O O O 0. 5'-0" - STUB -OUT FOR 1 �_�+� o 0 GAS METER O ° U 0 CV = • MEASUREMENTS ARE FROM FINISHED FLOOR • ROUGH -IN GAS TO RIGHT (ALWAYS) - 12" OFF -CENTER • ROUGH -IN ELECTRIC TO LEFT (ALWAYS) - 12" OFF -CENTER GAS CONNECTION DETAIL **ONLY APPLIES TO HILLSBOROUGH AND PASCO COUNTY** RAFTER SPAN TABLE MEMBER SIZE AND SPACING MAXIMUM LENGTH MEMBER CONNECTIONS* 2" X 4" @ 16" O.C. 7'-5" (2) 16d TOENAILS 2" X 6" @ 16" O.C. 10'-8" (2)16d TOENAILS 2" X 8" @ 16" O.C. 13'-9" (3) 16d TOENAILS 2" X 10" @ 16" O.C. 16'-5" (1) USP HTW20 OR (3)16d TOENAILS 2" X 12" @ 16" O.C. 19'-3" (1) USP HTW20 OR (4)16d TOENAILS 2" X 4" @ 24" O.C. 6'-1" (2) 16d TOENAILS 2" X 6" @ 24" O.C. 8'-6" (2) 16d TOENAILS 2" X 8" @ 24" O.C. 11'-0" (2)16d TOENAILS 2" X 10" @ 24" O.C. 13'-0" (3)16d TOENAILS 2" X 12" @ 24" O.C. 15'-4" (1) USP HTW20 OR (3)16d TOENAILS * TOENAIL CONNECTIONS DESIGNED FOR SHEAR ONLY (i.e. RAFTER TO RIDGEBEAM). ** SOUTHERN YELLOW PINE, 55 PSF LOADING Boise Joist Blocking Use 3" (10d) nails at 6" o.c. Load bearing walls higher than 15001b. BLOCKING PANEL, INTERIOR Vertical load transfer =1900 plf max. along bearing wall Required on interior walls : - for vertical load transfer when load bearing - for lateral support when joists meet over wall, or wall stacks directly over wall or beam below Load bearing wall must stack over blocking and wall or beam below.* i/ Provide adequate bearing for each lapped joist. Use 10dx3" nails at 6"o.c. for all joist blocking panel *Non -stacking walls (quash block) 10dnails SECTION @INT. BRG. WALL require additional consideration.- 2x4 minimum Bearing wall, Versa -Lam LVL or N.T.S. Glulam Beam MINIMUM SPACING = 2x GREATEST KNOCKOUTS) ALLOWED DIMENSION OF LARGEST HOLE IN BEARING ZONES D (KNOCKOUT EXEMPTS) (see table below) D (see table below) DO NOT cut, notch or drill flanges 6" A 1 z' ROUND HOLE MAY 61, 6", DO NOT CUT HOLES BE CUT ANYWHERE IN CANTILEVER LARGER THAN 1%" THE WEB. PROVIDE AT ROUND IN LEAST 3" OF CLEARANCE CANTILEVERS. FROM OTHER HOLES MINIMUM DISTANCE FROM SUPPORT, LISTED BELOW, IS REQUIRED FOR ALL HOLED GREATER THAN 1%" S 4 -0 1f -'I` 'I' 2 142" 1'-3" 1-3' 4'-7'" 1'-11 ` '-4' 2,-9' S'- ' S' 7," _ A 10 jr i f 12 'I'- ' 1"" .1, . 1,-2. I''-5,. 1,Lg. Z-4" '-11" S'-7"' 4_2'" 4' S-4 - ._.._ 11S 1't'" 1,_1," 11-2" 1,^2," 1._7 ° 3'-2° ?I'-1[J..,,,. 6,_ ,7-2 " 20 1,," 1'-1„ 1, 2. 1'2'° 2 {Y. 3'-J. 4'-{J'" 4'-10" S'-11'" 6'-11,. 7''-1,° S'-11,. 24 T-0'" 1,-1,. 1 Z' 1'-3" 2' 9' 3' 7"° 4-` 6'-10" 7-2' Ste„ �, , 10,E NOTES: 1. JOISTS MUST BE PROPERLY DESIGNED TO MEET BUILDING CODE REQUIREMENTS. 2. TABLE IS FOR UNIFORMLY LOADED MAXIMUM LOADS OF 40 PSL(LIVE) AND 15 PSF (DEAD) ON SIMPLE SPAN APPLICATIONS ONLY. 3. REFER TO JOIST SPECIFIER GUIDE FOR INSTALLATION AND OTHER INFO. 4. SELECT A TABLE ROW BASED ON JOIST DEPTH AND THE ACTUAL JOIST SPAN ROUNDED UP TO THE NEAREST TABLE SPAN. SCAN ACROSS THE ROW TO THE COLUMN HEADED BY THE APPROPRIATE ROUND HOLE DIAMETER OR RECTANGULAR HOLE SIDE. USE THE LONGEST SIDE OF A RECTANGULAR HOLE. THE TABLE VALUES IS THE CLOSEST THAT THE CENTERLINE OF THE NEAREST SUPPORT. 5. THE ENTIRE WEB MAY BE CUT OUT. DO NOT CUT THE FLANGES. HOLES APPLY TO EITHER SINGLE OR MULTIPLE JOISTS IN REPETITIVE MEMBER CONDITIONS. 6. FOR MULTIPLE HOLES, THE AMOUNT OF UNCUT WEB BETWEEN HOLES MUST EQUAL AT LEAST TWICE THE DIAMETER (OR LONGEST SIDE) OF THE LARGEST HOLE. 7.1%" ROUND KNOCKOUTS IN THE WEB MAY BE REMOVED BY USING A SHORT PIECE OF METAL PIPE AND HAMMER. 8. HOLES MAY BE POSITIONED VERTICALLY ANYWHERE IN THE WEB. THE JOIST MAY BE SET WITH THE %" KNOCKOUT HOLES TURNED WITHER UP OR DOWN. 9. THIS TABLE WAS DESIGNED TO APPLY TO THE DESIGN TO APPLY TO THE DESIGN CONDITIONS COVERED BY TABLES ELSEWHERE IN HIS PUBLICATION. USE THE BC CALC SOFTWARE TO CHECK OTHER HOLE SIZES OR HOLES UNDER OTHER DESIGN CONDITIONS. IT MAY BE POSSIBLE TO EXCEED THE LIMITATIONS OF THIS TABLE BY ANALYZING A SPECIFIC APPLICATION WITH THE BC CALC SOFTWARE. HOLE CUTTING CHART N.T.S. Web Stiffener Fastener Schedule Joist Bearing Location Series Depth End Intermediate ® BCI5000s 9-1/2" 2-8d 2-8d 11-7/8" 2-8d 3-8d 14" 2-8d 5-8d BCI6000se BCI6500s® 9-1/2" 11-7/8" 2-8d 2-8d 2-8d 3-8d 14" 2-8d 5-8d 16" 2-8d 6-8d BCI60s® 11-7/8" 2-8d 3-8d 14" 2-8d 5-8d 16" 2-8d 6-8d BC190s® 11-7/8" 3-16d 3-16d 14" 5-16d 5-16d 16" 6-16d __J 6-16d Plumbing Joist �When joists meet over wall, provide 13/4" minimum bearing for each. I -Joist can be offset up to 3" to avoid vertical plumbing 3" max JOISTS OFFSET N.T.S. Joist hanger USP MUC 5/8"0 THRU BOLT US ML R TRUSS 'OP PLATE I.0 TYPICAL USP MUGT15 TO BUILT-UP COLUMN DETAIL TYPICAL HUS INSTALLATION MIN. EMBEDMENT SCHEDULE FOR AND QUANTITY )F FASTENERS TYPICAL HTA 20-18 / HTA 20 INSTALLATION A/C CHASE 4" PVC SLEEVE THRU STEM WALL Backer block (12" wide min.) ;III —III —I I I —I I I-Tll—t�hl I I Nail with 10-10d nails. -I 11=1 11=TI 1=T—% Install tight to top flange. SLEEVE THRU STEM SEE PLAN FOR FOUNDATION INFO a ^ 4'' STEM FOUNDATION \ \ GRADE Filler block. r \ Nail with 10-10d nails. Backer block required where top mount hanger load exceeds 250 lbs. Install tight to top flange. 1/4%2" gap Backer Block "Top Mount' "Face Mount" Backer block shall be tight Backer block shall be tight to bottom of top flange with to top of bottom flange with 1/4"-2" gap at top of bottom 1/4"-2" gap at bottom of top flange, flange. eb stiffner as Web stiffeners are not required when top required if hanger flange is laterally supported by joist hanger. doesn't meet height requirements I 0.6 X Joist p j�depth of I -JOISTS BUCKETS N.T.S. REINF. SEE PLAN rvu �.nri�� 4 r_v�l SLEEVE THRU FOOTING MONO FOUNDATION TYP. FND. PENETRATIONS SCALE: N.T.S. LC SE HTA 20-18 / HTA 20 INSTALLATION @ MID SPAN NOTE: UPLIFT VALUE IS BASED ON S.P.F. USP RT16 USING 16-8d x1 1/2" NAILS UPLIFT =1030# TYPICAL RT16 INSTALLATION TYPICAL MTW INSTALLATION TOP (2) #5's x 4'-0" CENETERED @ PIPE PENETRATION d" a a :I I I WI I I —I WI I f=1 . 11=1 I I— o 12" BELOW GRADE PLUMBING LINE i—PVC OR SCH40 SLEEVE �• - d ° 1=1I1=III- • IIlIIi� �I� SEE FND. PLN. SIZE & REINF. PIPE VERTICAL THRU FND. TOP (2) #5's x 4'-0` CENETERED @ PIPE PENETRATION /r_ PVC OR SCH40 SLEEVE PLUMBING LINE d m •°• • ° SEE FND. PLN. SIZE & REINF. PIPE PERPENDICULAR TO FND. TOP (2) #5's x 4'-0" CENETERED @ PIPE PENETRATION PVC OR SCH40 SLEEVE PLUMBING LINE ° atd a n T ° T .Q SEE FND. PLN. SIZE & REINF. z — o (0 Z CO z� Q a O Q 4 w �U — W (D-0 F_ Lv E V) to o 0 U m r W vM C O Cl) a3�M 0 0 0 allEO a)— 00 = ai :E U_ co U0 C a, W o Y 0) LO O zr ch ¢ O N C B D C • N � O v rn N Z�; N 4s 0 elf M INo N M 04 Z I� CIO0, ,� 0-" o o J `n..- w v_tn m :3 - boa 0 oof 0 E m Cn � 2 m LL_ a°QM o 0 To the best of the Engfd`eedsJnowledge, i for ation, and belief, the structural plans a �cis�i�fiL�FioiT`s'contained within these drawings comply with the Florida Building Code 5th Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. 11 O O Z N 0 -N >=)fno a'03'n � LL Ln H Q U a00 Z J O W d- oZ x �o za z� aQ �F z W Y 0 o Uo zOww� x0Wz 2 J TJI '^ o��o w FzOO vJ LU W zz M Qo �W z 5 ro 5w 0 C < o o U 2 10 J Q 0 J < � x U. CaJ U 0 m J C/) o¢oa K O J Q Q F - W n °��° :;1a W Lr) o �oz J cW L Q v,awu ° Y Q 1 ri Ln Q z z ¢Wz t a Z z J ° m O N = az 0 rn T-11 a cn SCALE : AS NOTED DATE : 2/24/2014 TECH: ERAND VERSION N0. 2.0 SHEET NO. SIN 1 FOR UNDERLAYMENT REQUIREMENTS SEE R905. 12 (TYP.) VARIES / Ili (1) LAYER TYPE II (#30) UNDERLAYMENT FOR ROOF PITCH >4:12 (2) LAYERS TYPE I OR TYPE II (#15 OR #30) UNDERLAYMENT FOR ROOF PITCH 4:12 OR LESS. PRE ENGINEERED WOOD TRUSS @ 24" O.C. U.N.O. HURRICANE ANCHOR @ EACH TRUSS (SEE UPLIFT SCHED.) W/ METAL PL. UNDER EA. TRUSS MOISTURE BARRIER `SHINGLE ROOF 7/16" O.S.B. MIN. SEE ROOF /NAILING SCHEDULE ON SHT. CAM I 5/8" OR 1/2" HIGH ALUMINUM DRIP STRENGTH CEILING EDGE BOARD PER CODE (OR 5/8" GYP. TYPE "X" @ GARAGE ALUMINUM FASCIA W/A HABITABLE ROOM 12" N.O. 2x SUB FASCIA ABOVE) W/DRYWALL EE SOFFIT SCREWS @ 7" O.C. SHEET CEILING & 8" O.C. WALLS 8"x8"X16" KNOCK -OUT INSULATION PER BLOCK W! 1#5 CONT. CHART ON FLOOR FILLED SOLID W/GROUT PLAN 1x2 P.T. HORIZONTAL NAILER 8" C.M.U. TYPICAL STD. 90-HOOK (SEE DETAIL) TYPE "S" MORTAR ARCHITECTURAL FINISH 1x2 PT WD FURRING @ 24" O.C. 1/2" GYPSUM WALLBOARD (1) #5 VERT. IN FILL U.N.O. CELLS (SEE FOUNDATION PLAN FOR LOCATIONS) 1x4 P.T. BASE NAILER 4"x4" INSPECTION 31/4" BASEBOARD PORT AT EACH FILLED CELL TYPICAL MIN. 2500 PSI CONC. SLAB M AT GARAGE CONTRACTOR MIN PSI MAY VARY PER TO CUT BLOCK OR POUR MUNICIPALITY. CURB DUE TO SLOPE CONCRETE SLAB W/ 6X6 n- NOTE:EXTEND W1.4XW1.4 WWF OR DECO FINISH 4" to 6" ^FIBERMESH" BELOW GRADE c °° 2 co_ D 6 MIL VAPOR 00 BARRIER COMP. SOIL.I (COMPACTED TO 95% —I I I I =III=III 11— MODIFIED PROCTOR I I I I I I -III -I I I I ASTM D1557) 3" MIN. CLR. (2) #5 REBAR CONT. ON 3" CHAIRS TYP. 4" 1'-4'° STD. 90 HOOK (SEE U.N.O. DETAIL) TYPICAL WALL SECTION A SCALE: 3/4" =1'-0" S3 OPT: DEPRESS SLAB 5 %" DEEP AND 6" BEYOND DOOR TO - RECEIVE PAVERS! DRIVEWAY CONCRETE SLAB PAVERS� BLOCK WALL BEYOND 14 O.H.D. RECESS z cv I— " 4" II" o0 J. r III�II SEE A/S3 0R J/S6 J -III I I Ii 11 1 1 1 PFLI _I P FOR REINF. INFO. 3" MIN. CLEARANCE 1' 4" (1 STORY) / V-8" (1 STORY w/ DEPRESSED SLAB OPT.) 1' 8" (2 STORY) GARAGE DOOR SLAB RECESS J.1 SEE TYP. WALL SECTION FOR SCALE: N.T.S. S3 ADDITIONAL INFORMATION. 2x #2 SPF STUDS - @16" O.C. W/ (2) 16d TOENAILS T & B 2x P.T. PLATE --\ (2) #5 CONT. ON 3" CHAIRS (TYP.) D =LI.=III—I m D =.1 1'IIIIIIIIIII III IIIIIII (1) ROW 2x BLOCKING @ MID HGT. FOR WALL HGT. <_ V-6". (2) ROWS 2x BLOCKING @ 3rd PTS FOR WALL HGT. > 8'-6". 1/2" GYP. WB (MIN.) @ GARAGE SIDE IF z APPLICABLE. 1/4" DIA. X 31/4" TAPCONS @ 24" 0/C & @ 6" MAX FROM END OF 2 x PLATE _ .6x6W1.4xW1.4 r WWF OR FIBERMESH —I I I —III —III= I I Ti-I I -I I -I r TYPICAL INTERIOR BEARING WALL W/OUT UPLIFT r SEE TYP. WALL SECTION FOR ADDITIONAL SLAB INFORMATION. LOAD BEARING OR EXTERIOR WALL SEE CC/S3 OR — G/S3 FOR ANCHOR BOLT INFO. (IF NO UP LIFT ON WALL SEE GG/S3) *USP SPT22 TYP. - MONO OR STEMWALL- FOOTING MONO SHOWN FOR CLARITY ' NOTE: *FOR BEARING WALL WI UPLIFT ONLY SCALE:3/4"=V-0" S3 2x S.P.F. STUDS @ 16" O.C. 5/8"OR 1/2" HIGH STRENGTH `-TRUSS BOTTOM CHORD OR 2x4 BLOCKING 5/8"OR 1/2" HIGH STRENGTH —� `-TRUSS BOTTOM CHORD OR 2x4 BLOCKING W/ (U.N.O.) (OR %" GYP. TYPE "X" @ W/ 2-16d TOE NAILS @ EACH END 2-16d TOE NAILS @ EACH END GARAGE W/A HABITABLE ROOM (U.N.O.) (OR %" GYP. TYPE "X" @ ABOVE) SEE UPLIFT SCHEDULE FOR UPLIFT GARAGE W/A HABITABLE ROOM SEE UPLIFT SCHEDULE FOR UPLIFT CONNECTIONS. PROVIDE (1) USP HTW20 WHEN ABOVE) CONNECTIONS. PROVIDE (1) USP HTW20 S.P.F. DOUBLE TRUSS ALIGNED WITH STUD BELOW WHEN TRUSS ALIGNED WITH STUD BELOW 8"x8"x16" NOMINAL BLOCK WITH TOP PLATE S.P.F. DOUBLE TOP PLATE 3/8" MORTAR BETWEEN COURSES USP SPT24 CONNECTOR 211x S.P.F. (OR EQUAL) STUDS @ 16" O.C. U.N.O. USP SPT24 2"x S.P.F. (OR EQUAL) STUDS @ 16" O.C. 1/2" CDX PLYWOOD OR 7116" O.S.B. CONNECTOR U.N.O. SHEATHING REQ'D. FOR ALL 1) ROW 2x BLOCKING @ MID HGT. FOR WALL 1) ROW 2x BLOCKING @ MID HGT. FOR EXTERIOR OR SHEAR WALLS AS HGT. < 8'-6". (2) ROWS 2x BLOCKING @ 3rd PTS WALL HGT. < 8'-6". (2) ROWS 2x BLOCKING INDICATED ON THE PLAN. ATTACH FOR WALL HGT. > 8'-6". @ 3rd PTS FOR WALL HGT. > 8'41 . SHEATHING W/ COMMON NAILS @ 4" O.C. @BOUNDARIES, 6" O.C. @ NSULATION PER CHART ON FLOOR PLAN NSULATION PER CHART ON FLOOR PLAN 3/8" MORTAR BETWEEN EDGES, AND @ 12" O.C. @ FIELD SLAB & BLOCK SP SPT22 CONNECTOR 5/8"° x 10" "J" BOLT @ 24" O.C. W/ SP SPT22 CONNECTOR 5/8"° x 10" "J" BOLT @ 24" O.C. W/ 2"°x3116"PLATE WASHER (TYP.) 2"°x3/16" PLATE WASHER (TYP.) T (ALT: 1/2"x12" TITEN HD @ 24" 2x P.T. BOTTOM PLATE (ALT: 1/2"x12"TITEN HD @ 24" 2x P.T. BOTTOM PLATE ELEV. 0'-0" O.C. OR 5/8"x10' WEDGE ANCHOR O.C. OR 5/8"x10' WEDGE ANCHOR A.F.F.@24"OC 2 @24"OC 21I 6x6W1.4xW1.4 WWF OR FIBERMESH ) WWF OR FIBERMESH q' z �3 1/2" MIN. �3 1/2" MIN. Z ELEV.-0'-31/2" , d O D D .. p ° ° _. I__ . I 11II _I—II1-1 D I —I I—IpbAFFO —TII I Ii I��II8 I �I _-- I =1 I I 1 11= - 1 I I= 1/2"(min.)- (min.)- 4"2x4 CONT. III' °° d 1/2 (min)- 4 111= I•IW I I —I I _N —"(minF1/2(i. 3 2 - ---.- GARAGE DEPTH VARIES =1 = ::::I III II— d(2) #5 CONT. 4„(2) #5 CONT. 4" 1' 8" U.N.O. MIN.U.N.O. MIN. TYPICAL BEARING WALL @STEPGARAGE SLAB AT STEP TYPICAL BEARING WALL STEP @ SHEARWALL3 "m44 - CC SCALE: 3/4"=V-0" S3 "SHEAR WALL" 2x STUD 8" C.M.U. 1 "x P.T. STUD d #5 VERT. IN FILLED CELL CV 5/8"4" "J" BOLTS BOLT @ 24" O.C. VERT. OR 518" x 6" EPDXY BOLT OR (6) 1/4"x3 1/4" TAPCONS SPACED EVENLY 2x P.T. PLATE ASSUMED FINISHED GRADE 00 ° � I=III=III=1I1=1I1=1I1=_� � D ° 1=III=III=III—III—III—III � g ° III—III=III—III—III—III N 1-1 1-1 I —I I —I I 1.-1I , 1I 111 I i 1 r 1 151I-1I1=1I'- FRAME WALL TO C.M.U. WALL CONNECTION rD� SEE TYP. WALL SECTION FOR ADDITIONAL SCALE: 314"=1'-0" S3 SLAB INFORMATION. 6x6W1.4xW1.4 31/2" WWF OR FIBERMESH min.) 4 ° ° GRADE 00 • a_ 1 1 1 11 1—III—I I —I -(1) #5 REBAR w/ OPT. III-III1 Ill- 11= 11=Ill- 11=SCREEN ENCLOSURE MIN. TYPICAL THICKENED SLAB EDGE L SCALE:3/4"=V-0" S3 BLOCK WALL BEYOND EXPANSION JOINT 13" —t O.H.D. RECESS M T=► -4- : A Ii. -1-i :4 Fq 1 —I I 1-4111 SEE A1S3 0R J/S6 J _I I I l FOR REINF. INFO. 3" MIN. CLEARANCE 1'-4" (1 STORY) 1'-8" (2 STORY) GARAGE DOOR SLAB RECESS SEE TYP. WALL SECTION FOR SCALE: N.T.S. �,,S3 ADDITIONAL INFORMATION. 1/2" OR 7/16" OSB MIN. PLYWOOD SHEATHING — NAILED W/ 8d COMMON NAILS @ 4" O/C BOUNDARIES, 6" O!C EDGES, AND 12" O/C FIELD. SHEAR WALL REQUIRES 2x BLOCKING @ SEAMS. (2) ROWS OF 2x BLOCKING @ THIRD POINTS SCALE: 3/4"=V-0" ens' -10��GJ -2x STUDS @ 16" O/C /- 1<8ULATION PER CHART ON FLOOR PLAN 7/8" STUCCO FINISH PER ASTM C. 926 APPLY 3 LAYERS W/ TOTAL THICKNESS 7/8" OVER 5/8"° x 10" "J" BOLT @ 24" O/C W/ 2"°X 3/16" METAL LATH. FIRST 2 LAYERS 3/8" THICK EACH. CONTINUOUS TO FOOTER BELOW 90 NOOK DETAIL PLATE WASHER TYPICAL 3RD LAYER 1/8"THICK. K.O. BLOCK MIN. 2500 PSI CONCRETE SLAB W/ SP SPT22 @ EA. STUD 6 x 6 W1 A x W1.4 WWF OR 2X P.T. PLATE 20" MIN. LAP [24" MIN. LAP] #5 REINFORCING FIBERMESH WEEP SCREED INSTALLED BAR PER MANUF. #3 OR #4 REINFORCING BAR #3 & #4 LAP SPLICE GRADE 40 MIN. Fy= 40ksi p D CV �• ..—� D _Z FINISH GRADE °O [GRADE 60 MIN. Fy= 60ksi] 25" MIN. LAP [30" MIN. LAP] 6 MIL VAPOR BARRIEIR� _IIII I II I I D ° I I�1=1 11=1 E— -`�' 1=1 I IW I ,L=. '- #5 REINFORCING BAR R 1 7/8" =�=�1 I I II I II i I.U. :� — #5 LAP SPLICE COMP. SOIL. (COMPACTED TO II I • D 95% MODIFIED PROCTOR ASTM I I I I I I—IIII 1=III=1 I I-1 I I—III- D1557) I II II�I I IIIII 111111 I I IIII Ill 4" 1'-4" TYPICAL EXTERIOR FRAME WALL FOOTING SEE TYP. WALL SECTION FOR ADDITIONAL SCALE: 3/4"=V-0" SLAB INFORMATION. P.T. 2x 1/2" GYP. BD. 2„ HOLD GYP. BD. e. 1/2" FROM SLAB 0� J CONT. BEAD SEALA& �i- ° . INTERIOR -31/2" � a ° CONCRETE NAILS W 1 1/2 EMBEDMENT @ 12" O.C. STAGGERED, FROM BOTTOM PLATE TO CONCRETE (MIN. SHEAR 180# MIN. TENSION 120#) CONCRETE SLAB 00 ' €= _ 1=__=I M 6 MIL VAPOR —1 7 BARRIERIa E S3 2X STUDS @ 24" O.C. U.N.O. GARAGE GYPSUM WALLBOARD U.N.O. W/ DRYWALL SCREWS @ 8"O.C. INSULATION PER CHART ON FLOOR PLAN CONT. BEAD SEALANT r 6x6W1.4xW1.4 N M WWF OR FIBERMESH '. a 36"MIN. LAP [36" MIN. LAP] 10" #6 REINFORCING BAR #5 STD. 90 HOOK #6 LAP SPLICE NOTE: SEE SECTION C/S3 FOR ADDITIONAL INFORMATION USP SPT22 CONNECTOR 2x P.T. PLATE SPACE ANCHOR BOLTS 6" MAX FROM IL w END OF 2" x PLATE LU U I—III=I_LI—II I_ o W 'I ,IIIIII�II I L1= D � ° 1I— (2) #5 CONT. =1 I ICI I II ON 3" CHAIRS 8" 1'-4" (TYP.) REBAR DETAILS rF SCALE: N.T.S. S3 FRAME -DOWN FALSE BEAM w/ (3) SEE PLAN 10d NAILS TO TRUSS TOP CHORD SEE ROOF PLAN AT 24" O.C. MAX. FOR TRUSS SEE PLAN FOR CONNECTION INFO TOP OF BEAM & LAYOUT DESIGN I W 11 SEE ROOF PLAN00 2x4 P.T. PLATE � pits^ o.s.e. COLUMN LOCATION 0'-0" FIN. FLR. FOR STRUCTURAL BEAM SIZE & CONNECTION INFO •- I I 2x4 #2 SYP P.T. FRAMING w/ MIN 7/16" O.S.B. SHEATHING Z ATTACHED PER NAILING w SCHEDULE ] W w oLU SEE FLOOR PLAN FOR STRUCTURAL COLUMN SIZE & BASE CONNECTION INFO. SECURE 2x4 P.T. BTM. PLATE w/ 1/4"x3" TAPCONS AT 8" O.C. TRIM PER PLAN SQUARE CMU BLOCK BASE, SIZE VARIES PER PLAN w/ MIN. (2) #5 VERTICALS FILLED SOLID BRICK PAVERS or SLAB PER COMMUNITY SPECS (1) ROW 2x BLOCKING @ MID HGT. FOR WALL HGT. s 8'-6". (2) ROWS 2x BLOCKING @ 3rd PTS FOR WALL HGT. > 8'-6". 1/2" GYP. WB (MIN.) @ GARAGE SIDE IF APPLICABLE. 5/8- EXPANSION BOLT @24 " O.C. W/ 7" EMBEDMENT (MIN. SHEAR 3500#, MIN. TENSION 2600#) E 6x6W1.4xW1.4 - WWF OR FIBERMESH r III 11111-III-I1J 8" TYPICAL INTERIOR BEARING WALL W/ UPLIFT rG SCALE: 3/4"=V-0" S 3 i A 1^1. n -nn I^- VARIES C .. C \AN A.. IA14 A a ) v OPTION #1 SEE TYP. WALL SECTION FOR ADDITIONAL SLAB INFORMATION. �- SLAB STEP & RECESS an S.G.D. ( M SCALE:3/4"=1'-0" S3 q MASONRY WALL AND11 PAD FOOTING 8" MASONRY WALL-71 EXTEND FILL CELLS c TO FOUNDATION PAD _9 CONT. FOOTING STEEL MAT REINFORCING. r ' M 00 GRADE _ ° < d d. z LUo = I— —III—III— = v '— a w LUIII=1 I I III=1 I1=1I I- z (U)LU 1=1 11=1 11=1 1=1 I I I I 1=1 I PE 1—' FOOTING 11 �1111i11�11i11�11�111111-III-III—' BEYOND PAD REINFORCEMENT 3" MIN. CLEARANCE (SEE SCHEDULE) FOOTING WIDTH SEE SCHEDULE PATIO COLUMN FTG. DETAIL N SCALE: N.T.S. S3 UI �' z o O C° z� z co 0 V) (D Q) C w (z 0 V — 0 w V) Lv '2 E o U) C') V U C° co LU Ol ca M F— E —� N 'O M O`oo = N U (° cU-a0 0 00 o ca °°)) U) n o Y <C LO O rnQo NC6DC X < CV LO N to ,r V oq. N O co Z all ::, fl =MS, a`&5' 00 C) m m N_E- [Liz a� Q Ms PF� Q J o To the best of the EnginieeAj�q�yuledge, irlforYnafion, and belief, the structural plans andxsplecifieAions contained within these drawings comply with the Florida Building Code 5th Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. O ON Z 0�1� ►�—II�MO Q��_Ln a V S a Ln <t F �" ` /\ a U �- 00 E Z W J�~ d' mi oZ �o z z<a <¢ U) --1 �zgO Q F- W z =owz 0 2r , O J w N �Zo W oLn L j Q }o } _ Tq xW z� Z � M z 0 -0 0 O C z j < U _ (� Q IO W� o� *' = X,06 O Uama k N � � z- W��� Q d- ~ 0 0o ��u-o Z r` W T- 1 Lr) a LL °� J LU Q oW8 P98 L!i Z a Z a Ln V m z Qo � ^ = T-i d cn SCALE : AS NOTED DATE : 2/24/2014 TECH: ERAN D VERSION N0. 200 SHEET NO. S3 (MONO) 12 :y7p) SEE ELEV. USP SPT24 @ EA. STUD CRICKET AS REQUIRED SINGLE 2x CONT. BASE (2) 2x6 OR (2) 2x8 TOP PLATE SEE PLAN (2) 2x HEADER TO SIT 2x6 / 2x8 WALL BEYOND FLUSH TO THE OUTSIDE SEE PLAN FOR HEADER SEE PLAN FOR SIZE CONNECTION 2x DEAD WOOD @ MID POI NT w/ (3)12d DOUBLE 2x TOP TONEAILS SPACED PLATE EVENLY HEADER FLUSH TO OUTSIDE OPTION 2x BLOCKING @ EACH END W/ 10d @ 4" O.C. FROM EACH HEADER FACE TO BLOCKING (2) 2x HEADER PER PLAN VARIES 2x BOTTOM PLATE W/ (1)10d @ 8" O.C. TO EACH HEADER FACE 2 x 6 (MIN.) FRAME WALL HEADER DETAIL 1 SCALE: N.T.S. S4 SEE TYPICAL WALL SECTION PRE-ENGINEERED WOOD TRUSSES @ 24" O/C UPLIFT CONNECTOR KNOCK -OUT (SEE SCHEDULE) BLOCK W/ (1) #5 DOUBLE 2x4 SPF #2 TOP PLATE 2x S.P.F. STUDS @ 16" O.C. SINGLE 2x CONT, TOP PLATE W/ (2) 12d INTO TRUSS ABOVE 2x CLOSURE WALL W/ STUDS @ 16" O.C. W/ (3)10d TOENAILS T&B AS REQ'D 2x BLOCKING @ MID POINT EVERY OTHER +F-1�STUDWI(3)l0dNAS IL PLATE W/ (2)16d TO TRUSS BELOW 1/2" EXTERIOR GRADE SHEATHING FASTENED TO TRUSSES WITH 8d COMMON WIRE NAILS @ 4" O/C BOUNDARIES 6" O/C EDGES & 8" O/C FIELD USP SPT22 @ EA. STUD 2!V� 2x P.T. PLATE 5/8" x 10" "J" BOLT @ 24" O/C MAX W/ 8" EMBEDMENT El 8"X8"X16" K.O. BLOCK W/ 1 #5 CONT. AND FILLED SOLID W/GROUT 1 #5 VERT. IN CONC. FILLED CELL W/ STD. 90A HOOK IN K.O. BLOCK KNEE WALL ABOVE MASONRY WALL DETAIL MOUNTING BASE NOT SHOWN FOR CLARITY SEE DETAIL K/S4 SEAT FOR BLOCK IS POURED, IN PLACE CONCRETE GARAGE FLOOR SLAB TROWEL FINISH SEE GENERALNOTES SLOPE FORWARD FOR DRAINAGE BLOCKING (TYP.) V--ROOF TRUSS UPLIFT CONNECTOR (SEE SCHEDULE) MOISTURE BARRIER SCALE: N.T.S. SEE PLAN FOR FOOTING DIMENSIONS GARAGE ENTRY FINISHED MASONRY DETAIL SCALE: N.T.S. 1/2" MINIMUM CEMENT FINISH STANDARD 3" DIA. TEE THREADED 3" DIA. EXTENSION SCREW OFF CAP (3" DIA.) FOR CLEAN -OUT MIN. EXTENSION FROM EXTERIOR FACE OF BLOCK WALL IS 1 1/2" MAXIMUM EXTENSION FROM EXTERIOR FACE OF BLOCK WALL IS 2 1/4" VENT OR 2ND FLOOR TYPICAL C.M.U. WALL 3/4" FURRING STRIPS 1/2" GYPSUM BOARD W/ DRYWALL SCREWS @ 8" O.C. OR 4d DRYWALL NAILS TO DRAIN WALL CLEAN -OUT rA SCALE: N.T.S. S4 REFER TO WINDOW PRODUCT APPROVAL SHEETS FOR INSTALLATION INFORMATION BY MANUFACTURER. TYPICAL SECTION THRU WINDOW NOTCH LINTEL WHERE REQUIRED 7 FOR CONCRETE PLACEMENT / a. ,Q a 81, STD. 90°HOOK 8" LINTEL BEAM W/ (1) #5 CONT. IN OPENINGS GREATER THAN 6'-0" WIDE (U.N.O. ON PLAN) OPENING FILLED CELL W/ (1) #5 VERTICAL SEE FDN. PLAN FOR LOCATION NOTES: 1O FILL LINTEL AND ALL CELLS ABOVE LINTEL. NOTE: FOR BEAM DEPTH 22", PROVIDE A 4" x 4" INSPECTION PORT @ EACH VERTICAL REBAR & DIRECTLY ABOVE THE LINTEL. O VERIFY THAT ALL REINFORCEMENT HAS BEEN PLACED PROPERLY. O3 SEE FLOOR PLAN FOR ADDITIONAL INFORMATION. ® OPENINGS LESS THAN OR EQUAL TO 6-0" IN WIDTH DO NOT REQUIRE ADDITIONAL STEEL REINFORCEMENT UNLESS NOTED ON FLOOR PLAN. TYPICAL FILLED LINTEL ASSEMBLY SCALE: N.T.S. WIDTH OF OPENING VARIES 4" FORM CONCRETE INSET TO 1/2"X91/2" PLYWOOD CREATE A SOLID BASE FOR BLOCK WALL ABOVE. SCRAP MATERIAL J 10 T (u O FORM CREATES CONCRETE RECESS TO 2x4 (NOM.) RECEIVE GARAGE DOOR AND TO ALLOW FOR WATER SHED. KEEP STIFFENER BACK FROM SIDES ENOUGH TO ALLOW SPACE FOR FLAT MASONS TOOLS (THIS IS A RECOMENDATION FOR CONSTRUCTION OF THIS FORM. ANY MATERIAL OR CONSTRUCTION METHOD MAY BE USED PROVIDED END PRODUCT MEETS THE SHAPE AND DIMENSIONS OF THIS DRAWING.) MOUNTING BASE SHOWN IN POSITION GARAGE ENTRY FORM DETAIL 2x6 MOUNTING BASE �8x8x16 C.M.U. GARAGE DOOR GARAGE DOOR ROLLER CONNECTION ASSEMBLY :.,:: •,: �— GARAGE FLOOR ,./ TRAVEL DIRECTION OF GARAGE DOOR MOUNTING BASE DETAIL SCALE: N.T.S. TRACK MOUNTING BRACKET GARAGE DOOR TRACK SCALE: N.T.S. POURED CONCRETE BASE FOR BOTTOM OF MOUNTING B BLOCK WALL. RECESSED SPACE TO BE 2" ABOVE FINISHED FOR GARAGE DOOR AND WATER GARAGE FLOOR. SHED FORWARD THIS DRAWING. PARTIAL INTERIOR ELEVATION SCALE: N.T.S. 2x TOP PLATE 7 5/8" 8" 7 5/8" 8" 7 5/8" 8" ❑ SOLID AREAS ARE ❑ ❑ ❑ STEEL AND GROUT ❑ ❑ INTERIOR WALL -\ ❑ ❑ ❑ DOOR OPENING DOOR OPENING EXTERIOR ❑ ❑ WALL ❑ ❑ ❑ ❑ FIT ❑ 1ST COARSE 2ND COARSE 3RD COARSE MASON TO LAY BLOCK AS SHOWN ABOVE. EVERY COARSE MUST BE BONDED TO THE COARSE BELOW. EVERY THIRD (3RD) COARSE THE 11" DOORJAMB WALL IS TO BE WOVEN INTO THE MAIN FRONT TO REAR WALL AS SHOWN. MASONRY LAYOUT rD SCALE: N.T.S. S'r� SOLID AREAS ARE STEELAND GROUT FULL 8x8x16 BLOCK DOOR OPENING -� SEE TYPICAL WALL SECTION 12 PRE-ENGINEERED WOOD TRUSSES @ 24" O/C (NP) SEE ELEV. UPLIFT CONNECTOR (SEE SCHEDULE) DOUBLE 2"x4" S.P.F. TOP PLATE 7/8" STUCCO FINISH PER ASTM C. 926 APPLY 3 LAYERS W/ TOTAL THICKNESS 7/8" OVER METAL LATH. FIRST 2 LAYERS 3/8" THICK EACH. 3RD LAYER 1/8" THICK. CRICKET AS REQUIRED USP SPT24 @ EA. STUD 1/2" EXTERIOR GRADE SHEATHING FASTENED TO TRUSSES WITH 8d COMMON WIRE NAILS @ 4" O/C BOUNDARIES 6" O/C EDGES & 8" BLOCKING (- O/C FIELD 2X4 PT STUDS @ 16" O.C. (2) 2X4 PT STUDS UNDER HIP CARRIER/GIRDER TRUSS - - - USP HTA20 @ EA. STUD I _\ L MAIN SPANROOF MOISTURE BARRIER TRUSS UPLIFT CONNECTOR 8"X8"X16" K.O. BLOCK W/ 1 #5 CONT. (SEE SCHEDULE) AND FILLED W/ GROUT 1 #5 VERT. IN CONC. FILLED CELL) W/ STD. 90' HOOK IN K.O. BLOCK VERTICAL JAM ALT. KNEEWALL ABOVE MASONRY WALL DETAIL 5/8"DIA. x 8" J-BOLTS AT 6-3/4", 41-3/4", 71", AND 96-3/8"ABOVE GARAGE FLOOR. ALL J-BOLTS WILL BE IN FILLED CELLS (2,000 PSI MIN. SCALE: N.T.S. CONCRETE). ANCHORS MAY BE COUNTERSUNK (BUT NOT REQUIRED) TRUSS BOTTOM CHORD OR 2x4 TO PROVIDE A FLUSH MOUNTING SURFACE. HORIZONTAL JAMBS DO BLOCKING W/ 2-16d TOE NAILS NOT TRANSFER LOAD. PIPE OR DUCT w/ PENETRATION THRU TOP PLATE w/ MORE @ EACH END WALL THAN 50% OF TOP PLATE WIDTH INSTALL SIMPSON a PSPN516Z w/ (12)16d NAILS w ° a DOOR STOP TOP SPLICE z a Q MOLDING 2 ROWS 10d @ 3IT -" O.C. (14 �'� 2 U) GARAGE NAILS TOTAL) EA. SIDE OF 2-16d NAILS @ 24" O.C. OR DOOR 48•�PLICE STAGGERED • N. EQUAL TO TRUSS BOTTOM CHORD OR BLOCKING 2 x 6 P.T. i (M�Nj 2x STUD @ 24" O.C. MAX. PROVIDE P.A.F. NAILS OR 2x P.T. PLATE EQUAL @ 12" O.C. SEE A/S3 FOR STAGGERED FROM BOT. PLATE TO CONCRETE REINF. INFO. W/MOUNTING ANGLE NOTE: REFER TO GARAGE DOOR PRODUCT APPROVAL SHEETS FOR DOOR INSTALLATION INFORMATION PER MANUFACTURER. TYPICAL INTERIOR NON - BEARING WOOD FRAME WALL J TYPICAL GARAGE DOOR BUCK K SCALE: N.T.S. S4 SCALE: N.T.S. S4 2x CRIPPLES @ - 16" O.C. W/ (2)12d TOENAILS T/B USP SPT4 w/ (6) - 10dx1%"@24" O.C. 10d NAILS @ 8"- O/C TYP. DOUBLE 2x —� CRIPPLE STUD TYPICAL (U.N.O.) HEADER SUPPORT NO. OF JACKS & STUDS REQ. AT OPENINGS OPENING 2" x 4" WALL 2" x 6" WALL STRAPS SIZE JACKS STUDS JACKS STUDS EA END EA END EA END EA END 1'-4' (1) (2) (1) (2) (1) USP LSTA30 4'- 9' (2) (3) (2) (2) (1) USP LSTA30 9' -16' (3) (4) (2) (4) (2) USP LSTA30 FLAT STRAPS PER CHART ABOVE TO BE BENT OVER TOP PLATE ** HOLD DOWN CONNECTIONS NOT REQUIRED @ BEARING WALLS NOTED WITHOUT UPLIFT SEE FLOOR PLAN NOTES FOR REQUIRED CONNECTION 2-ROWS 12d NAILS STAGGERED @ 12" O/C EACH FACE OR 3-ROWS 12d NAILS STAGGERED @ 12" O/C FOR 2"x10" OR GREATER HEADER \—(2) 2x HEADER SEE PLAN S4 INTERIOR HEADER BOX HEADER (1) 2x SILL PLATE W/ (2) ONLY 12d TOENAILS. EXTERIOR HEADERS (1) 2x SILL PLATE W/ (2) 12d TOENAILS. OPENING LARGER THAN 4 ft (2) 2x SILL PLATE W/ MP3 CLIPS EACH SIDE '-2x STUDS TYP. USP HTT16 TYP. U.N.O. SEE N/S4 ** HOLD DOWN CONNECTIONS Op�00,4 NOT REQUIRED @ BEARING WALLS NOTED WITHOUT UPLIFT P.T. BOT. PLATE WALL HEADER DETAIL Q SCALE: N.T.S. S4' -USP SPT4 SPT24 us 2X STUDS @ 24" O.C. A A /8"x10" "J" BOLT @ 24" O.C. MAX. MIN. (2) PER BOTTOM PLATE SECTION 2. P USP SPT4 C P.T. ATE \ �10d @ 8" O/C ATTACH ALL J EXTERIOR STUDS W/ 4 16d TOENAILS TO YOP PLATE NOTE: PLATE LENGTHS MUST BE BOTTOM SPLIC AT LEAST 4'-0" LONG. TYPICAL OVER STUD TOP PLATE SPLICE DETAIL rM SCALE: N.T.S. S4 F= 2240 LBS �7 USP nc uor or I'+ SPT24 or or if SP SPT22 USP SPT4 iR�_ 10( ST io -I M, TRANSOM FRAMING SEE SECTION AA/S1 AND BB/S1 FOR ADDITIONAL DETAILS RECESS LINTEL NAILED INTO TRANSOM FRAMING _USP SPT4 ix d ° ° a 2X8 P.T. BOTTOM P TE USP O uor or I •+ SPT24 or or U� SF TRANSOM FRAMING SEE SECTION AA/S1 AND BB/S1 FOR ADDITIONAL DETAILS RECESS LINTEL NAILED INTO TRANSOM FRAMING USP SPT22 SP SPT4 ° a ° nD 2X8 P.T. BOTTOM PLATE 5/8"x10" "J" BOLTS @ 24" O.C. MAX. (MIN. (2) PER BOTTOM PLATE) 2X TOP PLATE OVERLAPPING NAILS @ 6" %GGERED 30LTS @ 24" O.C. kX 2X P.T. PLATE 5/8"x10" "J" BOLT @ 24" O.C. MAX. B (MIN. (2) PER BOTTOM PLATE) 174 L ROOF TRUSS ABOVE 2X BLOCKING 0 (2)16d TOE NAILS EA. BLOCKING 2X8 WALL ABOVE ENTRY K.O. BLOCK W/(1) #5 CONT. & FILLED 5/8"X10" J-BOLTS @ 2-0" O.C. MASONRY WALL 10d NAILS @ 4 10d NAILS @ 6" O.C. STAGGERED A STAGGERED TRANSOM FRAMING 0 o BEYOND. LPLYWOOD 3LYWOOD FASTENED TO TRUSSES o E SHEATHING WITH 8d COMMON WIRE NAILS @ 4" S4 )/C BOUNDARIES 6" O/C EDGES B 8" 0/C FIELD PLYWOOD SHEATHING MASONRY P WALL BELOW 5/8"X10" J-BOLTS @ 24" O.C. MAX. (MIN. (2) PER BOTTOM T4 PLATE) ALTERNATE: 5/8" DIA. ATR EPDXIED MIN. 6" INTO BOND BEAM @ 24" O.C. FRAMING DETAILS ABOVE ENTRY rR SCALE: N.T.S. S4 Z M 0 — 0 Z `O N Q IDz*0 J z to 0 � cn w Q w E o co � O o U a) Cl) L.1..1 EE C'(°M (L 'O M — 0 O o 0 = ai U s IL ao 0 y n Qo LO 0 d Qrn rnQo A 1/rD. N,C B DC x co N fn o t CO V 4.. c, C'V O ; Z , 0 Q N W '. `i U. "Z o? —D�o o N1Fo�a; ,Ems-.., LL t m0 m dam: y� V r✓¢ m Q Q\O 0 To the best of the Engineer's knowleclge,�information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code 5th Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. O O Z N O a) I� 1- 4 Ln � O r>-+ V) M O M Q 7 Ln a .L r 11-111) < L_ LL. a, .-� Q U 0. 00 z WJ C) d- oz 0 �s Lu za <¢ U¢�� �z80 U zaW� 0 _ w z 2 x J oho 1� w O W o� zz z z c r Q 0 O o a U U)W O u_ H 00 c� .=.' 0 ULu a m a ZLu cV Q Q � W fo z 2 0 - a�a LLU J Lf) L'I"I ' z N O LU 8 wu OLL Y Q ~ Q z C ¢Wz aLn g Uj J Q ¢ o N = r, ,-I a cn SCALE : AS NOTED DATE : 2/24/2014 TECH: ERAND VERSION N0. 10 O SHEET NO. S4 MEN Nil Nil SP HGAM10 W/ (4) 4"x1-3/4" WEDGE OLTS & (4) SDS 114 1 1/2" SCREWS I SEE STRUCTURAL NOTES AND NAILING SCHEDULE FOR SHEATHING DETAIL TOP CHORD BLOCKING FOR FIRST FOUR ROWS OF TRUSSES @ EDGES OF 2x4 CRO 7BRACE— SHEATHING APPROX. 8" FROM TYPICAL @ RIDGE FASTENED AT 48" O.C. EACH JOINT W/ (3) 10d MAX. & (2)10d TOE NAILS @ EA. END @ 48" O.C. TOENAIL W/ ( NAILS SEE STRUCTURAL NOTES AND BACKNAIL W/ (2)16d NAILS @ 24 OUTLOOKER7 NAILING SCHEDULE FOR USP RT16 OR EQUAL @ 24" O.C. SHEATHING DETAIL @ 2"x4" EA. OUTLOOKER OUTLOOKER @ 24" O.C. 45' ± 24" MAX. TOP CORD BLOCKING 45°± 2X4 CONT"L" BRACE USP RT16 OR FOR FIRST FOUR FASTENED W/ (2) 10d EQUAL @ EA. ROWS OF TRUSSES @ 3"@ 24" 0/C. CMID OUTLOOKER EDGES OF HEIGHT "L" BRACE TO EXTEND SHEATHING TYP. 2X4 KICKER 2x8BRACE�TO EXTEND @LEAST 90 /o OF AT LEAST 90% OF WEB @ 8'-0"/C. 2x4 CROSS BRACE WEB LENGTH & NOTCH @ ' LENGTH (SEE TABLE) APPROX. 8" FROM BOTTOM CHORD (SEE 2x6 P.T. GABLE TRUSS RIDGE FASTENED AT TABLE) SILL 1/2" CDX PLYWOOD OR EACH JOINT W/ (2) 10d USP RT3A WITH 8-8d 7/16" OSB SHEATHING & (2)10d TOE NAILS @ • FROM LEDGER TP ATTACHED W/ 10d EA. END BLOCKING NAILS @ 6" O.C. EDGES GYPSUM WALL BOARD GABLE TRUSS AND 12" O.C. FIELD 2"x4" PANEL BLOCKING @ 48" O.C. FOR THE FIRST 1/2" CDX PLYWOOD OR 10dX3" @ 3" O/C THROUGH CHORD (4) ROWS OF TRUSSES FROM EA. END TYP. BOTTOM CORD ATTACHED W/ (2) 16-d TOENAILS 7/16" OSB SHEATHING ATTACHED W/ 10d NAILS INTO 2"x6" P.T. PLATE 2"x4" LEDGER (MATCH BOTTOM CHORD @ 6" O.C. EDGES AND 12" 2x4 'IT" ON TOP OF PANEL BLOCKING, WEEP SCREED SLOPE OF ADJACENT SCISSOR TRUSS) O.C. FIELD FASTEN WITH 10dx3" @ 4" O/C SPACED INSTALLED PER MANUF. 2"x6" P.T. SILL NOTCH "L" BRACE HERE @ 48" O.C. Lv MOISTURE BARRIER 5/8" x 10" "J" BOLT @ 48" O.C. WEEP SCREED 5/8"x 10" "J" BOLT @ 32" O.C. MINIMUM 6" FROM USP HTA20 OR EQ. @ 6'-0" O.C. TYPICAL. INSTALLED PER MANUF. PLATE SPLICES W/ 3/16"x2" 0 PLATE WASHER USP HTA20 EA TRUSS ALTERNATE USP LSTA18 STRAIGHT STRAP @ 4'-0" MOISTURE BARRIER @ O/C ALIGNED WITH GABLE WEB. ATTACH TO TRUSS VERT. WEB (24" O/C MAX.) W/7-10dx1 1/2" AND TO MASONRY W/ (3) 3/16"x 2 1/4" NOTE: IF EMBEDDED � TAPCONS. SECTION 2 STRAP MISSED VERTICAL SECTION WEB; USE MSTAM36 ON OUTSIDE SCALE: N.T.S. S5 SCALE: N.T.S. 55 REFER TO DETAIL J ON SHEET S5 FOR r r SEE STRUCTURAL— X-BRACING, AND TOP NOTES AND NAILING CHORD BLOCKING N SCHEDULE FOR INFORMATION 00 `° °° SHEATHING DETAIL 1 1 1/ •. 2"x4" CROSS BRACE WOOD TRUSSES 50 00 APPROX. 8" FROM RIDGE FASTENED AT 2x4 RAT RUN BRACING 7 1 12" 1 1 2" " EACH JOINT W/ (2) AT 24 O.C. ON TOP OF 10d & (2)10d TOE BOTT. CHORD FOR 4 NAILS @ EA. END TRUSS SPANS ATTACHED W/2 -16dil 2X4 PANEL BLOCKING AT EA. TRUSS JOINT (2) 2" x 4" LAMINATIONS W/ (1) ROW (3) 2" x 4" LAMINATIONS W/ (1) ROW (3) 2" x 6" LAMINATIONS W/ (2) ROWS OF @ 48" O/C FOR THE FIRST (4) ROWS OF 2X4 BLOCKING @ 24" OF STAGGERED 10d COMMON WIRE NAILS OF STAGGERED 30d COMMON WIRE NAILS STAGGERED 30d COMMON WIRE NAILS TRUSSES FROM EA. (D = 0,148", L = 3") OR EQUAL (D = 0.207", L = 41/2") OR EQUAL (D = 0.207", L = 41/2") OR EQUAL END TOP & O/C W/ 2 -16d TYP. TOENAILS @ EA. END NOTES: BOTTOM ATTACHED 1) ADJACENT NAILS ARE DRIVEN FROM OPPOSITE SIDES 4) FOR 4-PLY, PROVIDE 1/4" DIA. x 51/2" LAG SCREWS OR EQUAL W/ (2) 16-d TOENAILS MASONRY WALL OF THE COLUMN (SPACE AS SHOWN FOR 3-PLY) ARCHITECTURAL FINISH 2) ALL NAILS PENETRATE AT LEAST 3/4 OF THE THICKNESS 5) FOR 5-PLY, PROVIDE 1/4" DIA. x 7" LAG SCREWS OR EQUAL OF THE LAST LAMINATION (SPACE AS SHOWN FOR 3-PLY) EXT. WALL CONN. a� 3) EACH 30d COMMON NAIL MAY BE REPLACED W/ (2)16d 6) REFER TO NDS SECTION 15.3 FOR ADDITIONAL INFORMATION NON - LOAD BEARING LOCATION COMMON NAILS. (ONE INTO EACH OUTSIDE FACE OF D B.U.C., SAME NUMBER OF ROWS, SAME SPACING) SEE TYP. WALL SECTION FOR ADDITIONAL INFORMATION. SCALE: 3/4"=V-0" S5 TYPICAL NAILING SCHEDULES FOR BUILT-UP COLUMNS r� 2"x4" OUTLOOKER @ 24" O.C. W/ (2) 10d PER JOINT IINIMUM 2x 'ROSS BRACING SEE PLAN FOR OCATIONS 10dx3" O/C @ TOENAIL 6" O/C RUNN W/ (2) 16d TYPICAL (2) 16d PER NAILS IT MAX JOINT CONTINUOUS BOTTOM CORD BRACING 2"x4" MIN. SEE M/S5 CROSS BRACING DETAIL ALTERNATE NON -DROP GABLE END DETAIL SCALE: N.T.S. S5 1 GABLE TRUSS "L" BRACE W/ 10d @ 4" O.C. 12 (SEE SCHEDULE FOR SIZE AND LOCATION) 6.9 MAX. S5 ° SCALE: N.T.S. \-CONT. BEARING GABLE END BRACING DETAIL MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION SCALE: N.T.S. CONNECTION 2X4 BLOCKING W/ (2)12d TOENAILS BACKNAIL W/ (2) 2x4 OUTLOOKER 16d NAILS @ 24 O/C TOP CORD BLOCKING FOR USP RT16 OR FIRST FOUR ROWS EQUAL @ EA. OF TRUSSES @ OUTLOOKER 24" MAX. EDGES OF SHEATHING TYP. Ir-"L" BRACE TO EXTEND AT LEAST 90% OF WEB LENGTH (SEE TABLE) GABLE TRUSS 1/2" CDX PLYWOOD OR 7/16" OSB SHEATHING : ATTACHED W/ 10d NAILS @ 6" O.C. EDGES AND 12" O.C. FIELD (2) 16d NAILS 2x4'7 ON TOP OF PANEL BLOCKING, FASTEN WITH 10dx3" @ 4" O/C USP HGA10 @ 36" O.C. DBL. TOP STUD WALL PLATE (SEE TYP SEC.) 2x4 BLOCKING 2x4 'IT" BLOCKING @ 48" O.C. 16d NAIL "L" BRACE ATTACHED W/ 10d NAILS @ 4" O.C. TYPICAL GABLE TRUSS WEB DOUBLE "L" BRACING DETAIL 5 SCALE: N.T.S. S5 2x4 "T" BLOCKING 2x4 BLOCKING @ 48" O.C. "L" BRACE ATTACHED 16d NAIL W/ 10d NAILS @ 4" O.C. Pill TYPICAL GABLE TRUSS WEB -' SINGLE "L" BRACING DETAIL 6 SCALE: N.T.S. S5 DIAPHRAGM BLOCKING @ 48" 0/C GABLE TRUSS TRUSS VERTICAL USP SPT24 @ EACH STUD (2) 2"x8" "L" BRACE J FASTENED WITH (3) SECTION 4 16d PER SIDE SCALE: N.T.S. S5 SCISSOR GABLE "T" BRACE 7 AS PER HIB 91 SCALE: N.T.S. S5 2 x 4 BLOCKING W/(2) 10d TOE NAILS @ EACH END @ 24" O/C (TYP) \-BRACING W/(3) 10d x 3" @ EACH CONN. @ 24" O/C MOISTURE BARRIER BOND BEAM MASONRY WALL ARCHITECTURAL FINISH EXT. WALL CONN.NON -LOAD BEARING LOCATION (UNEVEN CLG.) SEE TYP. WALL SECTION FOR ADDITIONAL INFORMATION. SCALE: N.T.S. "L" BRACING REQUIREMENTS STUD SPACING NO "L" BRACE (1) 2"x4" (U.N.O.) "L" BRACE 2"4" (U.N.O.) "L" BRACE 24" 010" - T-0" 3'-0" - 6'-0" 6-0" & GREATER SCISSOR GABLE - (1) 2"x8" #2 S.P.F. @ EACH VERTICAL AND (2) 2'W" FULL HEIGHT @ DIAPHRAGM BLOCKING NOTE: 1) "L" BRACE MUST EXTEND AT LEAST 90% OF WEB LENGTH EXCEPT, SCISSOR GABLE WHICH REQUIRES BRACE TO EXTEND FULL HEIGHT OF GABLE. 2) "L" BRACE TO BE FASTENED TO GABLE STUD WITH 1063" NAILS @ 4" 0/C. 3) SEE 6/S5 FOR MORE INFO. SCALE: N.T.S. PRE-ENGINEERED WOOD TRUSSES OVERLAP TRUSS BRACING AT LEAST TWO TRUSS SPACES SEE STRUCTURAL NOTES AND NAILING BACKNAIL W/ (2)16d NAILS SCHEDULE FOR SHEATHING DETAIL 2x4 OUTLOOKER @ 24" O.C. (OPTIONAL - SEE ELEVATIONS) SEE STRUCTURAL — TOP CORD BLOCKING USP RT16 OR EQUAL @ NOTES AND NAILING FOR FIRST FOUR ROWS 4" MAX. EA. OUTLOOKER SCHEDULE FOR OF TRUSSES @ EDGES SHEATHING DETAIL OF SHEATHING TYPICAL DOUBLE TOP PLATE 2"x4" CROSS BRACE 2x4 CROSS BRACE APPROX. APPROX. 8" FROM USP 8" FROM RIDGE FASTENED AT RIDGE FASTENED AT SPT4 @ EA. EACH JOINT W/ (2) 10d & (2) EACH JOINT W/ (2) STUD 10d TOE NAILS @ EA. END 10d & (2) 10d TOE 2X6 FRAMED WALL - SEE NAILS @ EA. END WALL SECTION FOR SPACING 2x4 PANEL BLOCKING 1/2" CDX PLYWOOD OR 7/16" @ 48" O/C FOR THE OSB SHEATHING ATTACHED FIRST (4) ROWS OF W/ 10d NAILS @ 6" O.C. EDGES TRUSSES FROM EA. AND 12" O.C. FIELD END TYP. TOP & (2) 16d NAILS BOTTOM ATTACHED 2X4 PANEL BLOCKING @ 48" 2x4 BLOCKING W/ (2) 16-d TOENAILS O.C. FOR THE FIRST (4) ROWS OF TRUSSES FROM EA. END 2x4 "T" ON TOP OF PANEL TYP. TOP & BOTTOM ATTACHED BLOCKING, FASTEN WITH W/ (2) 16-d TOENAILS 10dx3" @ 4" O/C 2X4 LEDGER (MATCH BOTTOM CHORD SLOPE OF ADJACENT TRUSS) SECTION 3 SCALE: N.T.S. S5 BACKNAIL W/ (2) 2x4 OUTLOOKER 8d @ 6"O/C - 16d NAILS @ 24 O/C TOP CORD WOOD TRUSSES BLOCKING FOR USP RT16 OR FIRST FOUR ROWS EQUAL @ EA. OF TRUSSES @ OUTLOOKER 24" MAX. EDGES OF SHEATHING TYP. "L" BRACE TO EXTEND AT LEAST 90% OF WEB LENGTH (SEE TABLE) GABLE TRUSS 1/2" CDX PLYWOOD OR 7/16" (2) 16d NAILS OSB SHEATHING ATTACHED W/ 10d NAILS @ 6" O.C. O.C.. FIELD USP HGAM10 W/(4)-3/16"x1-3/4"SEE r77' PLAN FOR EDGE S & (4) SDS 1/4" x 1 1//2" SCREWS 2x4 "T" ON TOP OF PANEL BLOCKING, FASTEN WITH 10dx3" @ 4" O/C SECTION g SCALE: N.T.S. S5 `-MINIMUM (2) 16d PER JOINT \-MINIMUM 2X4 TRUSS BRACING TRUSS BRACING OVERLAP DETAIL SCALE: N.T.S. 6" OVERLAP M S5 I" BRACE W/ 10d @ 4" O/C (SEE SCHEDULE FOR SIZE AND LOCATION) @ EACH STUD GABLE END BRACING DETAIL SCALE:3/4"=1'-0" MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION HIP FRAMING REFERENCE PLAN 20'-0" MAX 20'-0" MAX "X" BRACE SEE DET. J/S5 CONTINUOUS BOTTO CHORD BRACING 2X4 MIN. d ---- O o � O z o -v LU m o o ' 0 Cl w o o X � o o w NOTE: 1) SEE TRUSS MANUFACTURER'S TRUSS ENGINEERING CUT SHEETS FOR ADDITIONAL PERMANENT BRACING THAT MY BE REQUIRED 2) "T" BRACING MAY BE USED IN PLACE OF PERMANENT BRACING PROVIDED IT EXTENDS OVER AT LEAST 90% OF THE WEB. REQUIRED MINIMUM PERMANENT TRUSS BRACING PLAN AS PER BCSI 1-03 SCISSOR TRUSS SCISSOR TRUSS W/ DROP CEILING BRACING DETAIL /TOP & BOTTOM CHORD GABLE END BRACING @ 4'-0" O.C. MAX. FOR FIRST (4) ROWS OF TRUSSES SCALE: N.T.S. 2X4 BRACING @ 48" O.C. CONTINUOUS TO FIXED LOCATION ATTACHED W/ 2-10d @ EA. TRUSS (NOTE: BRACING MAY BE PLACED ON EITHER TOP OR BOTTOM OF THE BOTTOM CORD) COSMETIC DROP CEILING FRAMING MEAN ROOF HEIGHT UP TO 30'-0" SCALE: NTS SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION WOOD FRAMED GABLE END BRACING DETAIL MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES SCALE: N.T.S. FOR WIND SPEED SPECIFICATION 0 Z o 0z� z� O z ��� CJ /V11 u/ C-0 4•-J t.0 %a 0 �U — 0 w V ry F- o I= to C)r' v ' - O o �✓ w a) Cl) 0'as� t—E — mach O o 0 �aa) co ca C0Q-o Qv� Qo A 1 ncaDc c.; v 0, N k''� a • �f qy 9. N Z 0 smf' z 6, ., �°' n Q C) ja e � _ no ,4 N S' ub all '' To the best of the Engineer's know; Wee, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code 5th Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. O C:) Z 0(v1� O M P-4 M CD Q V) Q U_ Ln �- �— ro L)a '-' 00 Q zru J W Ct- s oZ R z Qa 1¢ �z 0. �zo0, U Z al Cr o z = O W z 2 �U z J LU � J 11 `1� W zo W o� Zz Gn J ao � 5z ( M w1 g OU o -r 0 Z o3 J '0 U y y fV A LL oaoa Z w � J �� 1 ` �Qw0� a 0 $M�o z a LL W w J Lf) --I LcLJ G LLJ Q o z 0 1.-C) o W u LL Y 4 H A I\ k T.{ Ln Q z z ¢�z az J 0 aw 0 = n r-I 11 to SCALE : AS NOTED DATE : 2/24/2014 TECH: ERAND VERSION NO' ^ ■ 0 SHEET NO. S5 1X4 1/2" DRYWALL DOOR JAMB (REFER 1 X 4 1/2" DRYWALL DOOR JAMB (REFER 1 X 4 1/2" DRYWALL ♦ UNACCEPTABLE INSTALLTION DOOR JAMB (REFER TO SHT. SDW2-K1 P.T. TO SHT. SDW2-Ki TO SHT, SDW2-K1 FOR HT. SD DETAILS MAX PROPER INSTALLATION 8„ DO NOT DO THIS 2"x BOT. PLATE W/ (2) 10d @ 6" O.C. FOR CONN. DETAILS FOR CONN. DETAILS 1 X 4 ` #5 REBAR (TYP,) ' 3/4" PLYWOOD DECKING GLUED ATTACHED WALL SHEATHING TO 1 X 4 3-1/4" LONG X 3/16" 0 FURRING 3/16"$ X 3" LONG FURRING " TAPCONS 3/16 f7J X 3-1/2 LONG FURRING #5 REBAR ` 6" O.C. AND ILED W1 8d EDGES AND 12" O.C. FIELD 2X BOTTOM PLATE W! 8d @ 4" O.C., 2 ROWS STAGGERED TAPCON. INTO TAPCONS STAGGERED STAGGERED @ 16" 2X8 (TYP,) ` ' BLOCK@ SPACING8 �� 1 DETAIL P.T. STAGGERED @ 16" O.C. O.C.O2-ROWS INTO 2-ROWS INTO 1X8 PER MANUFACTURE MASONRY THROUGH 1-1 /2" DETAIL MASONRY THROUGH 1�STD.` 3 DETAIL 90 D. 90° HOOK (TYP.) 2x BAND JOIST W/ FACE NAIL 10d @ TOP & BTTM CHORD, AND (8) 1x4 P.T. & 1x8 P.T. 1 x8 P.T. & 2x8 P.T. FILL SOLID BOTH CELLS HOOK (TYP.) FACE NAILS 1 Od @ TRUSS VERT. WEB 3/16" x 3 -1/2" TAPCON @ 16- METAL SEAT PLATE O.C. & 4" FROM P.T. 3/16" x 3 -1/2" DOOR JAMB (REFER 1/2" DRYWALL NOTE: NOTE: DOOR JAMB (REFER EACH END W/ MIN 2" EDGE DIST. DOOR JAMB (REFER TAPCON TO SHT. SDW2-K1 FOR TO SHT. SDW2-K1 CONN. DETAIL 1 X 4 ' LAP SHEATHING TO BOTTOM OF BAND TO SHT. SDW2-K1 ` JOIST TYPICAL FOR CONN. DETAILS FOR CONN. DETAILS 10d @ 12, O.C. 1 X 4 _ J FURRING 2X8 P.T. WITH 3116" 0 X 3" LONG TAPCONS ' +2 NOTC EB @ FIRST COURSE USP HGAM10 @ 12" O.C. w!4-SDS 1/4x1 1/2" SCREWS INTO BAND 2X8 P.T. 2X ` 2x P.T. AS REQ'D STAGGERED @ 16" O.C. NOTCH AT I ` JOIST & (4) 3/16"x1-3/4" WEDGE 2x DETAIL 2 1/4" DETAIL 2-ROWS INTO MASONRY 3-1 /411 DETAIL ±5^ WEB FIRST 2 COURSES E ' BOLTS INTO K.O. BLOCK BUILDOUT @ OVER SIZE DOOR -WINDOW ROUGH OPENINGS CC FILLED CELL PER FOUNDATION PLAN FILLED CELL INSTALLATION H RETROFIT FOR MISSING EMBEDDED STRAP SCALE: N.T.S. SS SEE TYP. 2-STORY WALL SECTION FOR ADDL. INFO SCALE: N.T.S. SCALE: N.T.S. SS 2x8 P.T. BUCK -CONNECT TO BLOCK mill. SECTION UPLIFT CAPACITY = 945 # FOR 1 STRAP W/ 1/4" x 31/4" TAPCON (1 1/4" MIN. A -A =1890 #FOR 2 STRAPS FILL 1st4 COURSES EMBEDMENT INTO BLK.) 1/4" MAX j. SOLID W/GROUT T Z-W 8" 1-PLY PRE-ENGINEERED TRUSS 1 X 4 FURRING SOLID BLKG. AT TOP BTWN. 1/4" x 3 1/4" TAPCONS BLOCK HEADER ARCH BLKG. &BUCK __:;..:.: ; ;: ~.,. USP RT16M W/ (8) NA11 NAILS & (6) 4' x 24' •..:, TAPCONS 1/2" DRYWALL * (IF TRUSS IS 2 PLY INSTALL USP HTWM16 W/ (6) � � 8d NAILS AT 8„ O.C. AT BUCK 10d NAILS x 12In NAILS AND `''. 2 x 8 45 DIAGONAL 4 10d NAILS INTO O LEAVE A CUTOUT IN O.S.B. ON THE (4)' X 1 4" WEDGE BOLTS [ (1) STRAP =1225 # , 2 STRAPS 2450# () �) BRACE(S) 2 x 8 BRACE/ BLKG. INSIDE TO ALLOW FOR INSULATION d 7/16" OSB TO BE INSTALLED BOND BEAM OR CAST FOR OVERHANGS BETWEEN OVER 1 1/2" BUILT BUCK ARCH PANEL CUT HOLE IN O.S.B. FOR „ . IN PLACE BEAM CONTACT ENGINEER OF RECORD FOR POLY -CELL IN THIS AREA E (NOTCH) SCRIBE (NOTCH) 2 x 8 45 DIAGONAL BRACE AT EA. FURTHER INSTRUCTIONS. , BACKSIDE TO FIT ARCH (4) 10d NAILS INTO 2 x 8 FACE OF ARCH W/ (3) 10d NAILS AT EA. END RETROFIT TRUSS DETAIL OVERRAN � . ° • �� : �... CONNECT W/ 8d NAILS BRACE/ BLKG. < . N.T.S. 'M 2 x 4 SOLID BLKG. (FULL WIDTH OF WALL BTWN. OSB INSTALL WDW. SCREW ANCHOR ) PROVIDE TAPCON WITHIN + INTO ARCH BLKG. PER ARCH FACES W (4)10d NAILS THRU OSB INTO 2 x 8 RETROFIT WALL OVERHANG DETAIL (NTS) 4" MIN. OF BRACE INSTALLATION DETAILS A -A PROVIDE TAPCON PER WDW. INSTALLATION DETAILS OR THRU 2 X 4 #2 SYP SCAB TO SIDE OF TRUSS AS SHOWN FOR O.H. UP TO 2'-6" FOR OVERHANGS BETWEEN 3/4" TO 1 1/2" 1-1/2" THK. OR MORE BUCK WITHIN 6" MIN. OF START OF ARCH 2X6 SYP #2 CONT. (MATCH TRUSS DEPTH * DOUBLE 2x4 SCAB FOR 2'-6" TO 4'-0" O.H. START OF ARC IF TRUSSES USED) W/ (3) #6 X 4'Y." WOOD NOTE: FOR OVERHANGS LESS THAN 3/4" - NO REPAIR REQ'D. 4' MAX. RAD. SCREWS @ 16" O.C. MAX. OR IF MASONRY X 0� (2) 10d NAILS @ 8" O.C. FRygN TO TRUSS TOP CHORD ARCH DETAIL WALL USE (3)1/4" X 31/2" TAPCONS AT 16" SCALE: N.T.S. SS O.C. 12 + + �FN + OiTN PLYWOOD SHEATHING 1_ 11 11- 11 5 0 JACK TRUSS PROVIDED BY SEE + TRUSS COMPANY OR PLAN 2x6 #2 SYP @ 24" O.C. + + + + AlLfINISH FLO 2 x 8 BUCK - CONNECT TO BLOCK SECTION + + BLOCKING AS ° WITH 1/4" x 31/4" TAPCON (1 1/4" MIN. B-B ROOF SHEATHING ATTACHED + REQUIRED , 1EMBEDMENT INTO K.) /4" MAX PER NAILING SCHEDULE ALL TO SUPPORT TRUSS + ° . ° as " #5 BAR BLOCK HEADER SOLID BLKG. AT TOP BTWN. ARCH Z-0" 8" (5) -12d NAILS + SOFFIT + .; ► P ° :' °` • :� . ► 10 p b CENTERED W/ 1 X 4 FURRING BLKG. & BUCK 2X6 TO 2X4 USP RT3A 2X4 SYP r ®s . P • . ° ' • .' "P 9� K IN TOP o EACH TRUSS _ o ; ' KNOCKOUT / N " ° CHAIR BLOCK 8d NAILS @ 8" O.C. AT BUCK' LVERT. W1 (10d , , PROVIDE 2 x 8 DIAG. BRACE BT LS AT EA. END NAILS PROVIDE (2) MIN. PROVIDE 2x CONNECTOR �® _ y MONO FOOTING •> , ° ( ° VERT. BRACES WHEN HGT. OF BRACE EXCEEDS 24" TAPCON AT EA. SIDE BUCK - (1) WITHIN 4" 1CZd NAILS JACK TRUSS PROVIDED BY SEE LINTEL SEE SCHED.I SIZE AND REINF. PER PLAN AND SECTION DETAILS -� LEAVE A CUT OUT IN O.S.B. ON T MIN. OF START OF TRUSS COMPANY OR 2x4 USS COM AN e 2 x 8 VERT. BRACE(S) INSIDE TO ALLOW FOR INSULATION ARCH #2 SYP @ 24" O.C. ENTER SO IT CLEAN FILL DIRT Z TO BE INSTALLED UP PLWD. BUCK - 4'-0" MAX SEE PLAN PRECAST LINTEL °, ° STANDARD CDBUILT SCRIBE (NOTCH) BACKSIDE 7/16" OSB ARCH PANEL 2X4 SYP #2 CONT. (MATCH TRUSS DEPTH SEE ELEVATION 90° #5 BAR IN ° HOOK cv TO FIT ARCH CONNECT W/ IF TRUSSES USED W/ 2 #6 X 4'/" WOOD ) () FOR OVER HANG FILLED CELL, -; -, •,, -, 8d NAILS 2 x 4 SOLID BLKG. (FULL WIDTH OF WALLS) START OF ARC 4' MAX. RAD. SCREWS @ 16" O.C. MAX. OR IF MASONRY (MAX. 4'-0") • • • , • , It It - �' s INSTALL WDW, SCREW BTWN. OSB ARCH FACES W/ (4) 10d NAILS EQUAL EQUAL WALL USE (2)1/4" X 31/2" TAPCONS AT 16" ,=.• •.- o.- �d �.-,• THRU OSB INTO 2 x 8 O.C. s• s• s• ANCHOR INTO ARCH BLKG. PER INSTALLATION DETAILS 13 ARCH DETAIL K SECTION @ ENTRY L SECTION @ ROOF EXTENSION STEMWALL FOOTING SIZE AND REINF. PERLAN AND STEMWALL MONO TO STEMWALL FOOTING SCALE: N.T.S. SS SCALE: 3/4" = 1'-0" SS SCALE: 3/4" =1'-0" SS SECTION DETAILS SCALE: 3/4" =1'-0" GLASS BLOCK INSTALLATION NOTES NOTE: IF RETROFIT FILLED CELL CONDITIONS A) COVER SILL AREA WITH A HEAVY COAT OF ASPHALT EMULSION, ALLOW EMULSION TO DRY AT LEAST 2 HOURS BEFORE PLACING MORTAR. EXCEED 3 PER PROJECT, CONTACT ENGINEER OF RECORD ( ) B) ADHERE EXPANSION STRIPS TO JAMBS AND HEAD. MAKE CERTAIN EXPANSION STRIP FOR ADDITIONAL INSTRUCTION. EXTENDS SILL. C) SET A FULLLL MORTAR BED JOINT, APPLIED TO SILL. MASONRY WALL. SEE PLAN FOR EXISTING BOND BEAM. D) SET LOWER COURSE OF BLOCK. MAINTAIN A UNIFORM JOINT WIDTH OF 3/8" PLUS OR MINUS REINFORCING. PROVIDE LOWER HOOKED DOWEL 1/8". ALL MORTAR JOINTS MUST BE FULL AND NOT FURROWED. ALL MORTAR SHALL BE "S" "N". SEE SHEET D2 AND DRILLS/4"X6"MIN. HOLE TYPE OR STEEL TOOLS MUST NOT BE USED TO TAP BLOCKS INTO POSITION. (PLACE EXPANSION STRIP FLOOR PLAN FOR A RUBBER CRUTCH TIP ON END OF TROWEL TO TAP BLOCK INTO POSITION.) DO NOT 20 ga. PANEL MORE INFO SET BAR IN EPDXY REALIGN, TAP, OR OTHERWISE MOVE BLOCK INITIAL PLACEMENT. FOR SOLID GLASS ANCHOR HTT16 W/ (18) -16d NAILS TO CAP TO PREVENT LEAKAGE BLOCK IT MAY BE NECESSARY TO USE WEDGES IN THE MORTAR JOINTS OF THE LOWER W.W.M. AT PERIMETER COURSES TO PREVENT THE MORTAR FROM BEING SQUEEZED OUT. 1/4 EXPANSION BOLT (2 WHERE THIS CONDITION STUDS & (1) - 5/8" DIA. ALL #5X6 EMBEDDED INTO E) INSTALL PANEL REINFORCING IN EVERY OTHER MORTAR BED HORIZONTALLY AND IN JOINTS 9 ga. PANEL PER ANCHOR) (1) #5 BARS CONT. OCCURS TOP WITH MIN. 3" THREAD ROD EPDXIED W/ SIMPSON "SET" EPDXY MIN. a Er Z EXISTING BOND BEAM IMMEDIATELY ABOVE AND BELOW ALL OPENINGS WITHIN PANELS. (THE SAME SPACING REINFORCING COVER 6'-0" 5" EMBEDMENT & 3"MIN. O SHALL APPLY TO PANEL ANCHORS WHEN USED AT JAMBS AND HEADS IN LIEU OF CHANNEL (EVERY OTHER F.F. EDGE DISTANCE FILL CELL FULL HEIGHT W/ OR CHASE SURROUNDS.) RUN REINFORCING CONTINUOUSLY FROM END TO END OF PANELS. LAP REINFORCING NOT LESS THAN 6 INCHES WHENEVER IT IS NECESSARY TO USE MORE COURSE) EXPANSION STRIP NON SHRINK GROUT. THAN ONE LENGTH. DO NOT BRIDGE EXPANSION JOINTS WITH REINFORCING. INSTALL °. c v o 0 LU ate. A REINFORCING AS FOLLOWS: * :.... Y:: =.; >' ::_: = SEALANT =III=1 I=III=III=III; T LL a 1 PLACE LOWER HALF OF MORTAR IN BED JOINT. DO NOT FURROW. '; ';: ` , . ; :::;:::^ ;' '.;; `:. g? e �( �f —L=I I -III- r * PRESS PANEL REINFORCING INTO PLACE. —L �- .. U Z 5X6 EMBEDDED INTO * COVER PANEL REINFORCING WITH UPPER HALF OF MORTAR BED AND TROWEL ;; ;. .': 6" MIN. LAP SPLICE W/ REINFORCING PANEL T EXISTING FOOTING 2-#5X6' IN CONC. SMOOTH. DO NO FURROW. :: ".` ° p:° I I I=�LI—I . \ ire c„ DRILL 3/4"X6" MIN. HOLE FILLED CELL F) PLACE FULL MORTAR BED FOR JOINTS NOT REQUIRING PANEL REINFORCING - DO NOT '''.' '''' ` '' :.``. `::•...• GRADE �. I I I—�- SET BAR IN EPDXY ,. FURROW. MAINTAIN UNIFORM JOINT WIDTH. ..,:,; 5r,:;<; 6" MIN. LAP p g G) SET SUCCEEDING COURSE OF BLOCKS. SPACE AT HEAD OF PANEL AND JAMBS MUST SPLICE REMAIN FREE OF MORTAR. NOTE: `' z \ ' H) STRIKE JOINTS SMOOTH WHILE MORTAR IS STILL PLASTIC AND BEFORE FINAL SET. AT THIS SEE GLASS BLOCK INSTALLATION NOTES. r TIME RAKE OUT ALL SPACES REQUIRING SEALANT TO A DEPTH EQUAL TO THE WIDTH OF THE SEALANT ° SAW CUT SPACES. REMOVE SURPLUS MORTAR FROM FACES OF GLASS BLOCKS AND WIPE DRY. GLASS BLOCK DETAIL \ ° . (2) #5 REBAR. MIN. 3" TOOL JOINTS SMOOTH AND CONCAVE, BEFORE MORTAR TAKES FINAL SET. (REMOVE WEDGES FROM LOWER COURSES OF SOLID BLOCKS AND POINT THE VOIDS WITH MORTAR.) GLASS BLOCK SHALL BE INSTALLED PER THE FLORIDA BUILDING CODE RESIDENTIAL SECTION R160 16"MIN. COVER EA. WAY A SECTION 1) AFTER FINAL MORTAR SET (APPROX. 24 HOURS), INSTALL PACKING TIGHTLY BETWEEN EXISTING FOOTING GLASS BLOCK PANEL AND JAMB AND HEAD CONSTRUCTION. LEAVE SPACE FOR SEALING. 1Q, SCALE: N.T.S. J) APPLY SEALANT EVENLY TO THE FULL DEPTH OF RECESSES IN ACCORDANCE WITH THE SECTION AT DEEP MONO FOUNDATION RETROFIT FOR MISSING MSTAM STRAP MANUFACTURER'S APPLICATION MANUAL AND INSTRUCTIONS. RETROFIT FILLED CELL DETAIL K) A MAXIMUM OF 60 SQUARE FEET OF GLASS BLOCK MAY BE INSTALLED IN ANY OPENING. _ SCALE: 3/4 -1-0 „ SCALE: 3/4 = 1-0 FOR WIND SPEEDS UP TO 110 MPH*, PER PITTSBURG CORNING RECOMMENDATIONS FOR SCALE: N.T.S. INSTALLATION OF GLASS BLOCK. U� z (0 z Q J O C/) 0 Q w n •U — 0 L" [u E 0 in Mo o w (CI (`) � o — U E2 , M O .20 = aim U(1) u- m 0Qo C_4 od Q0 �Qo A1 A I NCBDC f e i Sy to N ,4 V .n i%W Oo��� °N��°ooa J o Oki aQ Q`LL •� a w to �Z5LL' ��,,`r,. ,mac U p QB —5 t C"!'It To the best of the Engineer's n d�ed�4, i rmation, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code 5th Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. O CD z O a� Lf) ' ►>-�Lr)MO 4 M Ln •L a 0 N L_ Q LLL }— C- . n V CL � z z § E_ z J C:) J oZ �o z nQ f 0 clW K _ 2 Z p L. 2x� T� °N W mzo S� oin } o Z H T..� g C: M O J G U = iu Cj) 0 -' '< aYr- xo6 W o �aUdmrra N CD Lu 'i z a a ;� a o w L w -Q�? Q z *k Ln z a z O = J p Ln aZ SCALE : AS NOTED DATE : 2/24/2014 TECH: ERAND VERSION N0. 10 O SHEET NO. SS a p e CROSS BRACING DETAIL (TYP.) SCALE: 1/2" = 1'4" TRUSS NOTES: CONV. FRAMED RIDGE 1. WOOD TRUSS ERECTOR SHALL PROVIDE BRACING ACCORDING TO ANSI/TP1-2002 MAY BE NAILED (TRUSS PLATE INSTITUTE) NOTE THAT THE COMBINED WIND AREA IS GREATER W/ MIN. (4) 12d WHEN BEFORE THE ROOF SHEATHING IS APPLIED, AND BRACING SHALL THEREFORE BE IT LANDS NEXT TO INSTALLED AS THE TRUSSES ARE ERECTED. INADEQUATE BRACING IS THE MOST PRE-ENG. TRUSS — COMMON CAUSE OF ACCIDENT IN WOOD TRUSS CONSTRUCTION. FULL BUNDLES OF PLYWOOD SHALL NOT BE PLACED ON TRUSSES. THIS CONSTRUCTION LOAD SHOULD BE LIMITED TO 8 SHEETS OF PLYWOOD ON ANY PAIR OF TRUSSES & SHALL BE LOCATED ADJACENT TO THE SUPPORTS. NO EXCESS CONCENTRATION OF ANY CONSTRUCTION MATERIAL (SUCH AS GRAVEL OR SHINGLES) SHALL BE PLACED ON THE TRUSSES IN ANY ONE AREA THEY SHALL BE SPREAD OUT EVENLY OVER A LARGE AREA SO AS TO AVOID OVERLOADING ANY ONE TRUSS. 2. ALL BRACING (DB,CB,BB) SHOWN ABOVE SHALL BE IN ADDITION TO CONTINUOUS LATERAL BRACING SPECIFIED BY THE TRUSS MANUFACTER ALL LATERAL BRACING SPECIFIED BY TRUSS MANUF. SHALL HAVE ADDITIONAL DIAGONAL BRACES AT 20'-0" O.C. MAXIMUM. 3. ALL BRACES SHALL BE 2X4 NOMINAL DIMENSION LUMBER & SHALL BE ATTACHED W/ 2-16D NAILS AT EACH TRUSS INTERSECTION. 4. ADDITIONAL BOTTOM CHORD BRACING SHALL BE INSTALLED AS REQUIRED BY TRUSS DESIGN WHEREVER ADEQUATE STRUCTURAL CEILING ARE NOT ATTACHED DIRECTLY TO THE BOTTOM CHORD OF THE TRUSS. 5. PROVIDE TRUSS BLOCKING AT ALL TRUSS BEARING SUPPORTS WHERE TRUSS DEPTH EXCEEDS STANDARD HEEL HEIGHT. SEE TYP. TRUSS BLOCKING DETAILS 2X4 DIAGONAL AT 8'-0" O.C. 2X4 BLOCKING BETWEEN EA. TRUSS MAX & EACH END ALTERNATE A DIRECTION TYP. ----/—WOOD TRUSS A TYP. WOOD TRUSS BLOCKING DETAIL SCALE: 1 /2"=V-0" WOOD WALL OR TRUSS. SEE PLAN STRUCTURAL SHEATHING ATTACHED PER NAILING SCHEDULE VARIES W/ ROOF SLOPE 2X4 CONT. W/ (2) 16d COMMONS NAILS EACH STUD TYP. T&B TRUSS OR ROOF SYSTEM SHEAR TRANSFER EXTERIOR. WALL SCALE: 3/4" = V-0" CB rri j WM `, Wj i ill- v r a TYP. HAND FRAMING ABOVE TRUSS 2X4 STUDS & PLATES AT 2'-0" O.C. EACH DIRECTION TYP. U.N.O. 2x8 BLKING. NAILED @ EACH SIDE w/ (3) 12d NAILS WHEN REQUIRED w/ (2) USP HTW20 W/ (14) - 10d X 1 1/2" EACH B TB 7 PRE-ENG. TRUSS CONT. ROOF SHEATHING AT TRUSS TOP CHORD AT ALL HAND FRAMED AREAS TYP. DIAGONAL - AT 8'-0" MAX WOOD TRUSS SEE ROOF PLAN SHEATHING 2X4 BLOCKING BETWEEN TRUSSES SECT. A -A G.T. ADD 2X4 ALONGSIDE TOP CHORD WHEN REQ'D TO PREVENT PLYWOOD SPAN FROM EXCEEDING MAX 24" SPAN (EITHER SIDE OR BOTH IF REQ'D) PROVIDE 2X4 MIN. BLOCKING AT rk OF HIP/RIDGE, TYP.BETWEEN TRUSSES W/ (2) 12D NAILS EACH END TO TRUSS TOP CHORD TYP. ➢A TRUSS K HIP G.T (2) 12D NAILS — AT 12" O.C. MAX HIP/RIDGE BLOCKING DETAIL VERTICAL SCAB 2 x 6 #2 SPF 48" O.C. W/ (4) 10d TOP & BOTTOM OR USP RT7 OR HCLR/LL W/ 8 - 8d IN PLACE OF (4) 10d COLLAR TIE EVERY 3rd RAFTER 2X4 SPF 2 (2) #7X 3-1/2" WOOD SCREW EACH TRUSS OR USP RT7 @ 48" O.C. BEVEL CUTS (OPTIONAL) „ 2x8 #2 SPF RIDGE BEAM * * 2x6 #2 SYP RAFTERS FOR SPANS 4FT TO 8FT 2X4 RAFTERS FOR SPANS LESS THAN 4FT @ 2'-0"O.C. MAX. w/ (3) 10d COMMON TOENAILS TO RIDE BEAM 2X4 CONT. AT—/ CONC. MASONRY T & B CHORD STEEL OR WOOD BEARING SUPPORT A —A ALTERNATE BLOCKING DETAIL @ INTERIOR BEARING SCALE: 1/2" = V-0" PROVIDE BLOCKING AT ALL TRUSS BEARING SUPPORT WHERE TRUSS DEPTH EXCEEDS STANDARD HEEL HEIGHT VARIES ROOF SHEATHING ATTACHED PER 2X4 #2 SPF BRACING @ NAILING SCHEDULE 16" O.C. W/ (4) 12d COMMON TRUSSES. TOENAILS TO TOP SEE TRUSS PLAN PLATE & (2) 12d END MIN. (2) 2x4 FOR CONNECTION NAILS TO TRUSS FF EOp INFORMATION. BOTTOM CHORD VARIES SEE PLAN FOR WALL LOCATION a MIN. 2X4 #2 SPF STUDS @ v 16" O.C. W/ EXTERIOR SHEATHING ATTACHED PER NAILING SCHEDULE & (3) 12d TOENAILS TO SEE PLAN FOR PLATE BELOW TOP OF WALL o MIN. 2x4 #2 SYP P.T. PLATE °. W/ 1/2"X8" EPDXY ANCHOR MASONRY WALL SEE @ 3" FROM EACH END & PLAN FOR MORE o 16" O.C. MAX. INFO. ° SECTION @ ENTRY $ SCALE: 3/4" = V-0" USP LSTA18 CENTERED @ SPLIT TO TIE BEAMS TOGETHER SEE FLOOR PLAN FOR COLUMN SIZE & ADDITIONAL INFI SCALE: 1 /2"=V-0" USP HD4101F BUCK -- SEE ROOF PLAN FI MORE IN (2) 2x8 #2 SYP W 7/16" O.S.B. FLIT PLATE TOP @ TI BRG. TYPIC WALL NOTE: PENDING BEAM BEARING LOCATION, THE BEAM CAN SIT ON TOP OF COLUMN W/ (2) HTW20 STRAPS USP JUS46 OR JUS461F BUCKET TO COLUMN SUPPORT COLUMN BUILT-UP (2)-2x4's OR 4x4 W/ (2)-10d NAILS @ 8" O.C. EACH PLY (SHOWN AS 4 x 4) (2) USP HTA20's w/(10)-10d x 1 1/2 EA. TO COL. ALT: (2) USP MSTAM36 STRAPS CENTERED w/(13)-10d NAILS Ea TO COL. TIE BEAM BEAM @ RAISED ENTRY MASONRY WALL r4 SCALE: 1/2" = 1'4' SEE PLAN L. FOR CANT. SEE FLOOR PLAN FOR COLUMN SIZE & BASE 7116" OSB FLITCH PLATE CONNECTION INFO REQ'D ONLY WHEN INDICATED ON BM. 7116" OSB FLITCH PLATE SEE FLOOR PLAN FOR SCHEDULE/PLAN REQ'D ONLY WHEN COLUMN SIZE & BASE OPTION A INICATED ON B. SCHEDULE/PLANM OPTION B CONNECTION INFO OPTION C COMMON BM. TO POST ATTACHMENT SEE ROOF PLAN FOR BEAM SIZE & CONNECTION INFO. USP ST18 TYP. U.N.O. SEE FLOOR PLAN FOR _ COLUMN SIZE & ADDITIONAL INFO. (WOOD COLUMN SHOWN) 2X4 STUDS W/ USP SPT22 @ BASE SEE J/S6 FOR MORE INFO. A r__� A SEE PLAN FOR SEE PLAN FOR CANT. IF INDICATED O O CORNER SEE FOUNDATION PLAN FOR MORE INFO 5" COMMON BM. ATTACHMENT SCALE: 3/4"=V-0" EXTERIOR SHEATHING ATTACHED PER NAILING SCHEDULE 2X4 BASE PLATE W/ USP LSTA30 OR MTW12 TO FLOOR GIRDER BELOW @ 16" O.C. 16" FLOOR SYSTEM — FLOOR GIRDER SEE PLAN FOR SEE PLAN FOR DIRECTION CONNECTION SECTION @ FLOOR CONNECTION r22"� SCALE: 3/4" = V-0" SCALE: 3/4"=V-0" SEE 1/S5 FOR ADDITIONAL OUTLOOKER INFO. ju GABLE TRUSS 1/2" PLYWOOD (2) 16d NAILS TO EACH COMMON TRUSS/ FRAMING TYP TOP & BOTTOM BM. SPLICE OVER CL ///,-- CENTER OF POST MIDDLE [— SEE PLAN FOR 8d NAILS AT VALLEY TRUSS 4" O.C. INFO. MASONRY WALL BELOW: USP HTA16 @ 4'-0" O.C. TO GABLE MASONRY WALL TRUSS BEAM BELOW: USP OR BEAM HTW20 @ 4'-0" O.C. TO GABLE SEE TRUSS PLAN aTRUSS COMMON TRUSS '<. SEE ROOF PLAN FOR CONNECTION SECTION AT HIP GABLE 12 SCALE: 3/4" = 1'-0" EXTERIOR ATTACHED SCHEDULE KNEEWALL 2X4 #2 SYP NAILER. NAIL TO STUDS W/3-16d @ EA. STUD. TOENAIL EA. TRUSS TO NAILER w/3-10d JACK TRUSS (AS SHOWN) OR GABLE END SEE TRUSS LAYOUT CLIP EACH TRUSS (SEE ROOF PLAN FOR TYPE) FRAME OUT TO BLOCK EDGE SEE DETAIL 4/D1 FOR BEAM SIZE 2x SPF #2 AT 16" O.C. BUILDER FRAME RADIUS AS REQUIRED ENTRY FRONT WALL s SCALE: 1/2" = 1'4' USP JU26 OR IF 2 PLY ' TRUSS USP JUS26-2 TRUSS TO LEDGER 2X8 #2 SYP CONT. LEDGER w/ (4) 16d NAILS ATTACH NAILS INTO END OF EACH FLOOR TRUSS, 24" O.C. MAX. (AT EACH SIDE OF G.T. INSTALL (4) NAILS EACH SIDE) ROOF AND EXTERIOR SHEATHING ATTACHED PER NAILING SCHEDULE SEE 2ND FLOOR WALL SECTION FOR ADDITIONAL INFORMATION SEE FLOOR FRAMING PLAN AND J/S6 FOR MORE INFO. VERIFY WITH PLAN FOR LOCATION AND DIRECTION (IF PARALLE SEE 2/D2 FOR BLOCKING INFO) -MASONRY WALL (TYPICAL) SECTION AT LOW ROOF SCALE: 1/2" = 1'-0" LOW ROOF/WALL SHEATHING ATTACHED PER NAILING SCHEDULE 2x STUDS @ 16" O.C. W/ USP SPT22 @ BASE & SPT24 @ TOP 2x BLOCKING BETWEEN STUDS TO TRUSS W/ (2) 12d TOENAILS EACH END ( BETWEEN TRUSSES (2) 12d NAILS TO EACH VERTIVAL STUD) 2x BASE PLATE W/ (2) 12d NAILS @ 16" O.C. ALONG W/ USP MTW12 TO BLOCKING BELOW @ 16" O.C. PLYWOOD FLOORING LOW ROOF TRUSS W/— L (2) 2x6 BLOCKING UNDER FLOOR G.T. RAISED BOTTOM CHORD 2nd FLOOR WALL W/ USP SEE PLAN EXTENSION SEE TRUSS JUS24-2 EACH END MANUF. SPEC'S FOR CONNECTIONS TO G.T. SECTION @@ BUMP OUT 39 SCALE: 3/4"= V-0" DETAILS & SECTIONS 10 0 zo IDz� —0 z o J z V) (h Q) C i--d w �U - 12 0 w E E � YZ 0 co M U mco vM w E — q c' m m 2-0m O o0 = dj s U_ 00 0, Q 1, o 0 O V" Q 0) CL 0, Q O ®® N C B D C co C4 3 N "7 a -91 q. LL Cry - �yqN��OG��^`' al UM W N 0 I f +J ~W��� �s E S S To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code 5th Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. O O Z N � o ►>M � C)Q�_LO a .L n L_ Ln Q U_ �M QU a00 Z E W O Uj J d- oz =o �o Za z g i¢ U,00 r_�0 C,U FU Z Q ==WZ 2�ui J T� UU W � N W cn mow° o(n Z z 0 }o az > ,--I ZW CL U � 2: M w M O -0 06 o Z U C!) J ou_ ¢�¢0 o J Q x,0U W U r m a -oa T N I� Q Z¢a W Q J ;Q¢Q Q aow� -En Z Sao LU J Lr) ,--I W =5QC�= 0 8 W 0 W U 0 Y Q q Ln ¢ Z z �Ujo Q,Z IT as �Ln J [1 0 = Ln az SCALE: AS NOTED DATE ; 2/24/2014 TECH: ERAND VERSION N0. 10 SHEET NO. D1 a a THESE DETAILS ARE GENERIC AND MEANT TO SHOW GENERAL FLASHING AND WATERPROOFING METHODS TO BE USED. �nL n i Lq WEATHER dE BARRIER & tARILY SECURE WEATHER RESISITIVE BARRIER TAPE (ASSEMBLED WINDOW ) HEAD FLASHING TIE-IN INSTRUXTIONS; 1. Cut, fold up & temporarily secure weat barrier above header to allow for flashing installation 2. Self -adhered flashing plus head flashing under weather resistive barrier 3. Fold weather resistive barrier back over head flashing and seal with tape SELF -ADHERED FLASHING Scale: NTS FLANGED WINDOW FLASHING INSTALLATION AFTER WEATHER RESISTIVE BARRIER s DO NO' BOTTO FLANGE ,12 [•011�O• SELF -ADHERED FLASHING HALF ROUND WINDOW rLr�anLrv�a rv��nLLv�a SELF -ADHERED FLASHING DECK JOIST EXTERIOR SHEATHING WOOD FRAME CONSTR. SELF -ADHERED FLASHIN BY LAPPING DOWN OVER RIM JOIST AND UP WALL BY 6 IN. WEATHER RESISITIVE BARRIER SEAL TOPS OF JOI; UNDER DECKING (SEE DETAIL WP07) ED FLASHING E AM aSHING WEATHER RESISTIVE BARRIER DOOR ROUGH OPENING 3/4%1" BEAD OF CONSTR. ADHESIVE TO BE APPLIED UNDER THRESHOLD OF DOOR AND RETURN UP JAMB 6". USE LIQUID NAIL BRAND OR EQUAL WEATHER PROOF CAULKING SELF -ADHERED FLASHING SUBFLOOR SELF -ADHERED FLASHING EXTERIOR DOOR WITH DECK - SECTION A EXTERIOR SHEATHING 3/4"-1" BEAD OF CONSTR. ADHESIVE TO BE APPLIED UNDER THRESHOLD OF DOOR AND RETURN UP JAMB 6". USE LIQUID NAIL BRAND OR EQUAL WEATHER PROOF CAULKING SECTION -A (SEE DETAIL WP02) SELF -ADHERED FLASHING SEAL TOPS OF JOISTS UNDER DECKING (SEE DETAIL WP07) SELF-ADHER O SELF -ADHERED FLASHING EXTERIOR DOOR WITH DECK SELF -ADHERED FLASHING OUTSIDE CORNER NOT USED RIM JOIST INSTALL SELF -ADHERED FLASHING JAMB & HEAD FLASHING, SEE FLANGED WINDOW (SEE DETAIL WP01) SELF -ADHERED FLASHING, EXTEND A MINIMUM 6" VERTICALLY FROM BOTTOM OF THRESHOLD SELF -ADHERED FLASHING PATCH HERED FLASHING `QI WINDOW UNIT SLOPE 0.3 in: 12.0 in (0.6 cm : 30.5 cm) SELF -ADHERED FLASHING EXTERIOR CEMT. FIN. BUILDING PAPER WIRE LATH Q SELF -ADHERED FLASHING CEMT. FINISH SILL/ POTSHELF/ CHIMNEY SHOULDER MECHANICALLY FASTEN IF NEEDED IN CORNERS THROUGH SELF -ADHERED FLASHING RUBBERIZED RUBBERIZED ASPHALT ASPHALT ADHESIVE ADHESIVE SELF -ADHERED FLASHING F_ �i SELF -ADHERED FLASHING INSIDE CORNER SCORED RELEASE PAPER (BEFORE FOLDING, SCORE RELEASE PAPER TO EXPOSE ADHESIVE AS SHOWN) �-(Ground (�-�--- FOUNDATION WEEP SCREED NOT USED Water Resistant Barrier Lath Sheathing Stucco FLASHING REQUIREMENTS R612.10 Flashing, Sealants and Weatherstripping. Flashing and sealants for exterior windows shall comply with Section R703.8 R703.2 Weather -resistant sheathing paper. One layer of No.15 asphalt felt, free from holes and breaks, complying with ASTM D 226 for Type 1 felt or other approved water -resistive barrier shall be applied over studs or sheathing of all exterior walls. Such felt or material shall be applied horizontally, with the upper layer lapped over the lower layer not less than 2 inches (51 mm). Where joints occur, felt shall be lapped not less than 6 inches (152 mm). The felt or other approved material shall be continuous to the top of walls and terminated at penetrations and building appendages in a manner to meet the requirements of the exterior wall envelope as described in Section R703.1 Exception: Omission of the water -resistive barrier is permitted in the following situations: 1. In detached accessory buildings. 2. Under exterior wall finish materials as permitted in Table R703.4 3. Under Paperbacked stucco lath when the paper backing is an approved water -resistive barrier. R703.8 Flashing. Approved corrosion -resistant flashing shall be applied shingle -fashion in a manner to prevent entry of water into thewall cavity or penetration ofwater to the building structural framing components, Self -adhered membranes used as flashing shall comply with AAMA 711. The flashing shall extend to the surface of the exterior wall finish. Approved corrosion -resistant flashings shall be installed at all of the following locations: 1. Exterior window and door openings. Flashing at exterior window and door openings shall extend to the surface of he exterior wall finish or to the water -resistive barrier for subsequent drainage. Flashing at exterior window and door openings shall be installed in accordance with one or more of the following or other approved method: 1.1 The fenestration manufacturer's written flashing instructions. 1.2 The flashing manufacturer's written installation instructions. 1.3 In accordance with FMA/AAMA 100, FMA/AAMA 200, or FMA/WDMA 250. 1.4 In accordance with the flashing method of a registered design professional. 2. At the intersection of chimneys or other masonry construction with frame or stucco walls, with projecting lips on both sides under stucco copings. 3. Under and at the ends of masonry, wood or metal copings and sills. 4. Continuously above all projecting wood trim. 5. Where exterior porches, decks or stairs attach to a wall or floor assembly of wood -frame construction. 6. At wall and roof intersections. 7. At built-in gutters. R703.6.2.1 Weep Screeds A Minimum 0.019-inch (No. 26 Galy. sheet gage), corrosion -resistant weep screed or plastic weep screed, with a minimum vertical attachment flange of 3 1/2" shall be provided at or below the foundation plate line on exterior stud walls in accordance with ASTM C 926. SELF -ADHERED FLASHING PRODUCTS DETAILS TWO LAYERS OF FELT OR ONE LAYER OF HOUSE WRAP AND ONE LAYER OF FELT ARE REQUIRED BEHIND STUCCO. FBC R703.2.1 Detail Instructions Refer to the number marked as #Oin each detail that corresponds to the numbered items in the list of instructions below: 1. Install self -adhered flashing in order as shown by numbers 2. Install flashing and weather resistive barrier to form water shedding laps 3. Self -adhered flashing can be substituted for building paper 4. Split the release paper using the ripcord (Split release on demand, embedded in the adhesive layer) - for ease of installation and to minimize scoring cuts 5. Remove all release paper per standard installation instructions and adhere to substrate using a square piece of flashing material (6" x 6" Minimum) 6. Fold as shown by arrows 7. Angle of corner may vary, adjust folding of the flashing accordingly to fit tight to corner 8. Mechanically fasten as necessary Cement Plaster in accordance with ASTMC926 over wood 2nd floor Cement Plaster over block 1 st floor 7/8" Cement Plaster in accordance with ASTMC926 - Felt backed metal lathe in accordance with ASTMC1063 Building Paper -7/16" O.S.B. sheathing Metal Flashing Weep Screed Installed As Per Manufact. Specs. Maintain Bottom of Weep Screed 1 1/2" to 2" Above Roof Sheathing Note: The building paper and metal lath must be installed over the top of the weep screed. WEEP SCREED DETAIL SCALE: NOT TO SCALE 7/8" Cement Plaster in accordance with ASTMC926 Felt backed metal lathe in accordance with ASTMC1063 Building Paper 7/16" O.S.B. sheathing Stampede or similar cauk bottom joint only Weep Screed Installed As Per Manufact. Specs. 1/2" Cementitious Decorative Finish All inside and outside corner will need to be miter cut and caulked all butt joints need to becaulked using Stampede or Sim. caulk for all Z M 0 O - o z(0 z� Q Z 0 cn 4 -d LU M p OLU N Lv E o � Cn M v I f- O o U �D h LU �m m M c a3 co H- E - U as a M O O O = ai Ua) u. cc UnQo Y Q0 N O rnQo A 1 N C B D C ti N N Lo N a 0 oroM�oN N pZ WN tiz°° C, �_2th � -1 o Lu19s LL W Q"' DMN �W � Liar ° Lu Z a Q- •- Y Z -.rnm ca a?oQ �? Z C)U)m n o �p ii�rny m m Z .4 LL W N _J o O O U U I - To the best of the Engineer's knowledge, informa❑tion❑and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code 5th Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. O O Z N O av r-, I -I ,a-.+ O r>-a M O aU'rU'n °- Ul 0 Q � C)- M q) U Q� Z E W O W JCD d- 0 oZ o �2 zg <a L„ Z< FZ8O U Z Lu z Q � C) Z ¢ J U) a T'I -1 °�N Lli mZo ZZ L }o a V • LU = Tq gZ� Z LL =3 M O o O JQ U Lu X o F U - fV oaoa yyy.� y oC A 1` Z Lu J ZQ W0 awo o� °pgcr, Z Z Lu 0 2 0Qo� W Lr) LnoZ0 cW G Q U Y 4 C F 1` LP) Z Z nZZ Ln N Z rn r'I C L. V_ SCALE : AS NOTED DATE : 2/24/2014 TECH: ERAND VERSION No' 10 0 SHEET NO. W P Cv U) e5 N }' > U N Q O USP Florida Statewide Evaluation Report Simpson Florida Statewide Evaluation ReportQ. O L Stock No. Product Approval No. Basis Stock No. Product Approval No. Basis C6 ui O 0 O Q � 1O Q I- U) Q Z _ 0 ..�� O L v/ U I- o L W ¢ W z J z J W SHEET NO. PA 1.0-- A3 FL17244.1 ESR-3455 A23 FL10446.2 ESR-2606 HD210-2 FL17232.3 ESR-3445 HU210-2 FL10655.20 ESR-2549 HD212-2 FL17232.3 ESR-3445 HU212-2 FL10655.23 ESR-2549 HD216 FL17232.3 ESR-3445 HU216 FL10655.29 ESR-2549 PRODUCT APPROVAL SPECIFICATION SHEET O U_ 6 FL17232. ESR-3445 HD2 2 HU26 FL10655.31 ESR-2549 As required by Florida Statute 553.842 and Florida Administrative Code 96 72, please provide the information and approval numbers on the building components listed below if HD28-2 FL17232.3 ESR-3445 HU28-2 FL10655.34 ESR-2549 they will be utilized on the construction project for which you are applying for a building permit. We recommend you contact your local product supplier should you not know the O CU O > HD410 FL17232.4 ESR-3445 HU410 FL10655.44 ESR-2549 HD412 FL17232.4 ESR-3445 HU412 FL10655.45 ESR-2549 HD610 FL17232.4 ESR-3445 HU610 FL10655.51 ESR-2549 Category/Subcategory Manufacturer Product Description Approval Number(s) Test Pressures HD0410 FL17241.5 ESR-3444 HUC041.0 FL11468.11 SIM200804 HGA10KT FL17236.6 ESR-3448 HGA10KT FL11470.4 SIM200803 HGAM10KT FL17699.1 Evaluation Report HGAM10KT FL11470.4 SIM200803 HHCP2 FL17236.7 ESR-3448 HCP2 FL10447.2 ESR-2551 HTA16 FL17680.2 Evaluation Report HETA16 FL11473.5 SIM200802 HTA20-18 FL17680.2 Evaluation Report HETA20 FL11473.5 SIM200802 HTT16 FL17324.1 Evaluation Report HTT16 FL11496.1 ES-0130 HTT45 FL17324.1 Evaluation Report HTT22 FL11496.1 ES-0130 HTT4 FL17219.2 ER-0200 HTS16 FL10456.22 ESR-2613 HTT5 FL17219.2 ER-0200 HTS20 FL10456.23 ESR-2613 D. METAL LOUVERED DRS Curries Division of AADG, Inc 607,707,727,747,and 847 Single &Pairs of Doors FL11537.1 N/A (see inst sht) HTW16 FL17244.8 ESR-3455 HTS24 FL10456.24 ESR-2613 HTW20 FL17244.8 ESR-3455 HTS30 FL10456.26 ESR-2613 HTW24 FL17244.8 ESR-3455 HTSM 16 FL11473.11 SIM200802 A. SINGLE HUNG General Aluminum Company Series 1550/1570 FL15217.4 - FL15217.5 +50.0/-55.0 psf HTW30 FL17244.8 ESR-3455 HTSM20 FL11473.11 SIM200802 General Aluminum Company Series 1900/1970 FL15217.7 - FL15217.9 +40.0/-50.0 psf HTWM16 FL6223.2 Evaluation Report HGT2 FL10456.18 ESR-2613 HTWM20 FL6223.2 Evaluation Report HGT3 FL10456.19 ESR-2613 HUGT2 FL6223.3 Evaluation Report HUS210-2 FL10655.92 ESR-2549 HUGT3 FL6223.3 Evaluation Report HUS212-2 FL10655.93 ESR-2549 HUS210-2 FL17232.7 ESR-3445 HUS26 FL10655.94 ESR-2549 HUS212-2 FL17232.7 ESR-3445 HUS28 FL10655.96 ESR-2549 HUS26 FL17232.7 ESR-3445 HUS28-2 FL10655.97 ESR-2549 HUS28 FL17232.7 ESR-3445 LU24 FL10655.103 ESR-2549 HUS28-2 FL17232.7 ESR-3445 LU26 FL10655.104 ESR-2549 JL24 FL17232.8 ESR-3445 LUS210-2 FL10655.107 ESR-2549 JL26 FL17232.8 ESR-3445 LUS24 FL10655.109 ESR-2549 JUS210-2 FL17232.12 ESR-3445 LUS26 FL10655.111 ESR-2549 JUS24 FL17232.11 ESR-3445 LUS26-2 FL10655.112 ESR-2549 JUS26 FL17232.12 ESR-3445 LUS28 FL10655.113 ESR-2549 JUS26-2 FL17232.12 ESR-3445 LUS46 FL10655.118 ESR-2549 JUS28 FL17232.12 ESR-3445 LEG3 FL10667.71 ESR-2615 JUS46 FL17232.12 ESR-3445 MST60 FL10852.7 ESR-2105 KLEG3 FL17241.15 ESR-3444 LSTA12 FL10852.4 ESR-2105 KST260 FL17244.15 ESR-3455 LSTA15 FL10852.4 ESR-2105 LSTA72 FL17244.18 ESR-3455 LSTA18 FL10852.4 ESR-2105 LSTA15 FL17244.18 ESR-3455 LSTA24 FL10852.4 ESR-2105 LSTA18 FL17244.18 ESR-3455 LSTA30 FL10852.4 ESR-2105 Lomanco, Inc DA-4 Exahust Vent FL17202.1 N/A LSTA24 FL17244.18 ESR-3455 LSTA36 FL10852.5 ESR-2105 O'Hagin Manufactu r_ CIO ing, LLC O'Hagin's Cloakded Vent Tile FL16588.1 N/A LSTA30 FL17244.18 ESR-3455 LTT19 FL11496.3 ER-130 LSTA36 FL17244.18 ESR-3455 LTT20B FL11496.3 ER-130 Boral Tile Saxony 900 FL7849.13 - FL7849.16 N/A LTS19 FL17219.3 ER-0200 LTTI31 FL11496.3 ER-130 LTS20B F L 17219.3 E R-0200 LTS 12 FL 10456.29 ESR-2613 LTTI31 FL17219.3 ER-0200 LGT2 FL11470.7 SIM200803 LTW12 FL17244.8 ESR-3455 LS30 FL10446.15 ESR-2606 LUGT2 FL17240.2 ESR-3447 A34 FL10446.3 ESR-2606 MP3 FL17244.22 ESR-3455 LTP4 FL10446.19 ESR-2606 MP34 FL17244.23 ESR-3455 LS50 FL10446.16 ESR-2606 MP4F FL17244.24 ESR-3455 WM1416 FL10667.86 ESR-2615 MP5 FL17244.22 ESR-3455 MSTA12 FL10852.8 ESR-2105 MPH3516 FL17240.3 ESR�447 MSTA15 FL10852.8 ESR-2105 MSTA12 FL17244.18 ESR-3455 MSTA18 FL10852.9 ESR-2105 MSTA15 FL17244.18 ESR-3455 MSTA24 FL10852.9 ESR-2105 MSTA18 FL17244.18 ESR-3455 MSTA36 FL10852.9 ESR-2105 MSTA24 FL17244.18 ESR-3455 MSTC40 FL10852.11 ESR-2105 MSTA36 FL17244.18 ESR-3455 MSTC52 FL10852.11 ESR-2105 MSTC40 FL17244.26 ESR-3455 MTS12 FL10456.33 ESR-2613 MSTC52 FL17244.26 ESR-3455 MTS16 FL10456.34 ESR-2613 MTW12 FL17244.8 ESR-3455 MTS16 FL10456.35 ESR-2613 MTW16 FL17244.8 ESR-3455 MTS20 FL10456.36 ESR-2613 MTW18 FL17244.8 ESR-3455 MGT FL11470.9 SIM200803 MTW20 FL17244.8 ESR-3455 MBHA3.56/11.25 FL10866.12 ESR-2616 MUGT15 FL17240.5 ESR-3447 MBHA3.56l16 FL10866.12 ESR-2616 NFM35X12 FL578.2 Evaluation Report HDU2-SDS2.5 FL10441.4 ESR-2330 the applicable manufacturers installation requirements. Further, I understand these products may have to be removed if approval cannot be demonstrated during inspection. NFM35X16U FL578.3 Evaluation Report GLTV3.516 FL10667.8 ESR-261 (D 5 PAU44 FL17239.13 ESR-3449 FGTR FL11473.2 SIM200802 PAU66 FL17239.13 ESR-3449 CS16 FL10852.1 ESR-2105 PHD2A F L17219.4 ER-0200 H 1 FL 10456.5 ESR-2613 PHXU3516 FL17241.20 ESR-3444 H10 FL10456.6 ESR-2613 RFUS FL6223.5 Evaluation Report H10-2 FL10456.7 ESR-2613 RS 150 FL17244.27 ESR-3455 H 10A F L10456.6 ESR-2613 RT15 FL17236.11 ESR-3448 H3 FL10456.13 ESR-2613 RT16-2 FL17236.10 ESR-3448 H4 FL10456.14 ESR-2613 RT16A FL17236.10 ESR-3448 H5 FL10456.15 ESR-2613 � RT3A FL17236.11 ESR-3448 H2.5 FL10456.11 ESR-2613 RT4 FL17236.11 ESR-3448 H2.5A FL10456.12 ESR-2613 RT5 FL17236.11 ESR-3448 H8 FL11470.3 SIM200803 RT7 FL17236.11 ESR-3448 SP1 FL10456.41 ESR-2613 RT7A FL17236.11 ESR-3448 SP2 FL10456.42 ESR-2613 RT8A FL17236.11 ESR-3448 SP4 FL10456.43 ESR-2613 SPT22 FL17244.30 ESR-3455 SP6 FL10456.44 ESR-2613 SPT24 FL17244.31 ESR-3455 SPS FL10456.45 ESR-2613 o ICU SPT4 FL17244.32 ESR-3455 SPH4 FL10456.46 ESR-2613 SPT6 FL17244.32 ESR-3455 ESR-2613 SPH6 FL10456.47 SPT8 FL17244.32 ESR-3455 SPH8 FL10456.48 ESR-2613 SPTH4 FL17244.32 ESR-3455 U24 FL10655.141 ESR-2549 SPTH6 FL17244.32 ESR-3455 HHUS28-2 FL10655.3 ESR-2549 SPTHB FL17244.32 ESR-3455 HHU5410 FL10655.4 ESR-2549 SUH24 FL17232.14 ESR-3445 HGUS5.25/12 FL11468.11 SIM200804 THD28 FL17232.17 ESR-3445 HGUS414 FL11468.10 SIM200804 THD28-2 FL17232.17 ESR-3445 HD08-SDS3 FL10441.1 ESR-2330 THD410 FL17232.17 ESR-3445 MSTAM24 FL71473.19 SIM200802 o0 THD412 FL17232.17 ESR-3445 MSTAM36 FL11473.19 SIM200802 THD612 FL17232.17 ESR-3445 MSTCM40 FL11473.19 SIM200802 THDH414 FL17232.18 ESR-3445 HHETA20 FL11473.9 SIM200802 UGTS3F FL2033.1 Evaluation Report LGT3-SDS2.5 FL11470.7 SIM200803 UPHD8 FL17219.6 ER-0200 LGUM26-2 FL11473.12 SIM200802 product approval number for any of the applicable listed products. 1. EXTERIOR DOORS A. SWINGING ThermaTru Smooth -Star and Benchmark FL15225.5 +67.0/-67.0 psf ThermaTru Premium, Construction Series and Benchmark FL15225.6 +47.0/-47.0 psf ThermaTru Fiber Classic! Smooth Star FL15000.1 +55.0/-55.0 psf B. SLIDING General Aluminum Company Series 420l430 FL15332.1 - FL15332.5 +40.0/-40.0 psf C. SECTIONAL Clopay Building Products Residential WindCode Doors W5 (8X7) FL15279.37 +30.0/-32.0 psf Clopay Building Products Residential WindCode Doors W5 (16X7) FL15279.53 +30.0/-30.0 psf Clopay Building Products Residential WindCode Doors W6 (8X7) FL15279.85 +38.0/-42.0 psf Clopay Building Products Residential WndCode Doors W6 (16X7) FL15279.102 +37.0/-41.0 psf 2. WINDOWS B. HORIZONTAL SLIDER General Aluminum Company Series 1580/1590 FL15288.1 - FL15288.2 +40.OJ-50.0 psf General Aluminum Company Series 1980/1990 FL15288.3 - FL15288.4 +40.0/-50.0 psf C. FIXED General Aluminum Company Series 1550/1570 FL15278.4 - FL15278.5 +40.0l-40.0 psf General Aluminum Company Series 1900/1970 FL15278.7 - FL15278.9 +40.0/-50.0 psf D. MULLION General Aluminum Company 1445, 5347 and 5547 Vertical Mullion FL15333.7 N/A E. OTHER 3. PANEL WALL A. SIDING James Hardie Building Prod. Cemplank Lap Siding and HardiePlank Lap Siding FL13192.1 - FL13192.2 N/A B. SOFFITS Alside Solid and Vented Soffit FL15272.1 - FL15272.2 +70.0/-70.0 psf C. OTHER 4. ROOFING PRODUCTS A. ASPHALT SHINGLES Certain Teed Corporation CT20 (and AR), Landmark 30l40 (and AR), FL5444.1 N/A XT25 (and AR), XT30 (and AR) B. UNDERLAYMENTS Tamko 151b Felt Underiayment FL12328.6 N/A HomeGuard Building Products, Inc ToughSkin Synthethic Underiayments FL21675.1 N/A C. ROOFING FASTENERS NOT USED D. ROOF VENTILATORS Thompson Arch Metal Comp. Off Ridge Vents FL5219.1 - FL5219.3 N/A Florida Metal Products, Inc Vent RV10 FL2075.1 N/A E. ROOFING TILES Boral Tile Villa 900 FL7849.24 - FL7849.26 N/A F. OTHER 5. SHUTTERS A. STORM PANELS Global Protection Products Galvanized Steel Storm Panels FL15076.1 - FL15076.2 N/A Global Protection Products GPP Fabric Shutter Series 2000 FL15088.1 N/A Town and Country Industries Safety Edge Storm Panels FL12856.1 +54.0/-54.D psf All American Shutters Galvanized Steel Storm Panels FL17869.1 N/A 6. STRUCTURAL COMPONENTS A. WOOD CONNECTORS/ USP Structural Conn. see cha rt ANCHORS Simpson Strong -Tie see chart B. TRUSS PLATES ITW Building Components Alpine Truss Plates FL1999.1 - FL1999.4 N/A MiTek Industries, Inc. Truss Plates FL2197.1 - FL2197.5 N/A C. ENGINEERED LUMBER Boise Eng. Wood Prod. Versa -Lam SP FL1644.1 N/A Boise Eng. Wood Prod. Wood I -Joists ALLJOIST FL1645.1 N/A Weyerhaeuser Engineered lumber- TJI FL7630.1 - FL1630.11 NIA Weyerhaeuser iLevel Rim Board, LVL, PSL, LSL FL6527.1 - FL6527.4 N/A D. MATERIAL Cast -Crete Corp. High Strength Concrete Lintels FL158.1 N/A Commercial Concrete Products, Inc. High Strength Concrete Lintels FL1774 N/A Powers Steel, Inc. PSbox8LT, PSbox8LT(5-5/8) FL5450.1 N/A Powers Steel, Inc. PowerBOXB Lintels FL11383.1 N/A The products listed below did not demonstrate product approval at plan review. I understand that at the time of inspection of these products, the following information must be available to the inspector on the jobsite; 1) copy of the product approval, 2) the performance characteristics which the product was tested and certified to comply with, 3) copy of APPLICANT SIGNATURE DATE N Cn N +r N 0- O 2c, M 0 n- Florida Department of Business & Professional Regulation Page 1 of 2 Florida Department of Business & Professional Regulation Page 1 of 1 •� -4- r^f,, Building Codes and Standards 1/92017 Building Codes and Standards 1/92017 .= rR Department of Business & Professional Regulation Pagel oft (3)Florida V `v �O Product Approval Application Detail Product Approval Application Detail Building Codes and Standards 1/92017 c: O L FL#15000-R2 Product Approval Application Detail CO (5- FL#15225-R3 O LL Code Entityor Date Date Date Pending Date Code Entity or Date Date Date Pending Date FL#15332-R3 Products M 0 :- J 4_ (a Type Versio Manufacturer Contact Engineer & License Validated BY Validated Submitted FBC Approval Approved Status Type Versio Manufacturer Contact Engineer & License Validated By Validated Submitted FBC Approval Approved Status M O > Revision 2014 Therma-Tru Corporation p RickWright ht National Accreditation & Ran J. Kin P.E. g y g, 06/28/2015 06/13/2015 07/05/2015 A Approved Revision 2014 Therma-Tru Corporation Rick Wright Lyndon F. Schmidt, P.E. Ryan J. King, P.E. 06/28/2015 05/29/2015 07/05/2015 08/19/2015 Approved Quality Assurance Approved for Use Approved for Use Impact Design D -0 E O Category: Exterior Doors (419) 298-1740 Management Institute (813) 767-6555 Category: Exterior Doors (419) 298-1740 PE-43409 (813) 767-6555 Seq # Product Model, Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure � (D L L SubCategory: Swinging Exterior Door Assemblies g ry: g' g rick w@ wbldgconsultants. SubCategory: Swinging Exterior Door Assemblies rickw@rwbldgconsultants. 4 SERIES 420 ALUMINUM SGD REINFORCED SERIES 420 ALUMINUM SGD REINFORCED OX, 12l3l/2017 No Yes No N/A (n Q Co Q Compliance Method: Certification Mark or Listing com Compliance Method: Evaluation Report from a com XO, XX 96& uot;x96& uot; q G �� ('a �'+� -i-+ CD Florida Registered Architect or a Licensed Florida 5 SERIES 420 ALUMINUM SGD REINFORCED SERIES 420 ALUMINUM SGD REINFORCED XXX 12131/2017 No Yes No N/A FL#15225-R3 Products Professional Engineer 143"x96" •� - 7 SERIES 420 REINFORCED ALUMINUM SGD SERIES 420 REINFORCED ALUMINUM SGD OXO 12/3l/2017 No Yes No N/A Quality Assurance Approved for Use Approved for Use Impact Design Seq# Product Model. Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure FL#15000-R2 Products 8 SERIES 430/440 ALUMINUM SGD At; SERIES SERIES 430/440 ALUMINUM SGD XXX 12/31l2017 No Yes No N/A 5 e. "Smooth-Star" and " Benchmark by 6/8 and 810 Opaque and Glazed Fiberglass Door with 12/3112021 No Yes No N/A Quality Assurance Approved for Use Approved for Use Impact Design 143"x80"a NON -REINFORCED Therma-Tru"a and without Sidelites. Inswing and Outswing Sag # Product Model. Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure 9 SERIES 430/440 REINFORCED ALUMINUM SGD SERIES 430/440 REINFORCED ALUMINUM SGD 12/31/2017 No Yes No N/A 0 6 f. "Premium Series", "Construction 6/8 and 810 Opaque and Glazed Steel Door with 12l3l/2021 No Yes No NIA 1 a. "Fiber-Classic" or "Smooth-Star" 68#39;8 "Non-Impact" Opaque Fiberglass 12/31/2018 Yes Yes No N/A XXX 143"x96"a Series"a and "Benchmark byTherma-Tru" Transoms. With and Wthout Sidelites. Inswing and Door with & without Sidelite(s) - Outswing (X, OX with Transoms Outswing or XO, OXO, XX, OXXO Configurations) Florida Department of Business & Professional Regulation Page 1 of 1 Building Codes and Standards 1/92017 Florida Department of Business & Professional Regulation Pagel of Product Approval Application Detail Florida Department of Business & Professional Regulation Page 1 of 1 Building Codes and Standards 1/92017 LU FL#15279-R4 Building Codes and Standards 1/102017 Product Approval Application Detail Code Entity or Date Date Date Pending Date Product Approval Application Detail Type Versio Manufacturer Contact Engineer & License Validated By Validated Submitted FBC Approval Approved Status FL#15217-R4 Revision 2014 Clopay Building Products Company Mark Westerfield Intertek Testing Services NA, Gary Pfuehler 06/12/2015 03/19/2015 06/21/2015 Approved FL#11537-R6 Code Entity or Date Date Date Pending Date Type Versio Manufacturer Contact Engineer & License Validated By Validated Submitted FBC Approval roved Status Category: Exterior Doors (513) 770-6062 Inc. (513) 519-6566 Code Entity or ate Date Date Pending Date Revision 2014 MI Windows and Doors Brent Sitlinger Luis Roberto Lomas Steven M. Urich, PE 06/30/2015 06/25/2015 07/06/2015 08/19/2015 Approved SubCategory: Sectional Exterior Door Assemblies 9 rY� mwesterfield clo a .com @ P Y Tvpe Versio Manufacturer Contact Engineer Validated By Validated Submitted FBC Approved Status Compliance Method: Certification Mark or Listing Revision 2014 CURRIES Division of AADG, Inc Nelson Kraschel UL LLC Ted Berman, PE 07/21/2015 07/21/2015 07/27/2015 Approved Category: Windows Subcategory: Single Hung (717) 365-3300 PE-62514 (717) 317-8454 bsitlinger@miwd.com FL#15279-R4 Products Category: Exterior Doors (641) 423-1334 (305) 868-4707 Compliance Method: Evaluation Report from a Subcategory: Exterior Door Components nelson.kraschel@doorgro Florida Registered Architect or a Licensed Florida Quality Assurance Approved for Use Approved for Use Impact Design Compliance Method: Certification Mark or Listing up.com Professional Engineer Seq# Product Model, Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure 37 037 W5-09 PAN-21`151: 84A, 94, 73, 75, 1500, 190, 76, Steel Pan (min. 25 ga.) Single -Car (up to 9'0" wide) 05/21/2028 No Yes No +30 PSF/-32 FL#11537-R6 Products FL#15217-R4 Products 76V, 4RST, 4RSF, 6RST, 6RSF, 2RST, 48, 42, 55, 48B, WINDCODE® W5 Garage Door PSF Quality Assurance Approved for Use Approved for Use Impact Design Quality Assurance Approved for Use Approved for Use Impact Design 42B, 55S, GD5S, GD5SV, GR5S, GR5SV, AR5S, AR5SV, Sea # Product Model. Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure Sea # Product Model. Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure ED5S, EDSSV 1 607, 707, 727, 747, and 847 Single and Pairs of Doors Flush, Glazed, and Louvered single and pairs of 12131/2017 Yes Yes Yes N/A 4 SERIES GA 195 ALUMINUM SH SERIES GA 195 ALUMINUM SH NI 44X84 12/31/2017 No Yes No N/A hollow metal doors. 5 SERIES GA 195 ALUMINUM SH SERIES GA 195 ALUMINUM SH NI 54X72 12/31/2017 No Yes No N/A 53 053 W5-16 PAN-21`153: 84A, 94, 73, 75, 150Q 190, 4RST, Steel Pan (min. 25 ga.) Double -Car (9'2" to 160" 05/21/2028 No Yes No +30 PSF/-30 2 M, CM, and G Series Frames Three sided and four sided single and pairs of 12/3112017 Yes Yes Yes NIA 7 SERIES GA 195 ALUMINUM SH SERIES GA 195 ALUMINUM SH NI 54X72 12/31/2017 No Yes No NIA 4RSF, 6RST, 6RSF, 48, 42, 55, 48B, 42B, 55S, GD5S, wide) WINDCODE® W5 Garage Door PSF frames. Tansom frames. 8 SERIES GA 195 ALUMINUM TRIPLE SH SERIES GA 195 ALUMINUM TRIPLE SH NI 12/31/2017 No Yes No N/A GD5SV, GR5S, GR5SV, AR5S, AR5SV, ED5S, EDSSV CONTINUOUS HEAD AND SILL 108X72 NON 85 085 W6-09 PAN-2F153: 73, 75, 84A, 94, 42, 48, 42B, 4813, Steel Pan (min. 25 ga.) Single -Car (up to 9'0" wide) 05/21/2028 No Yes No +38 PSF!-42 9 SERIES GA 195 ALUMINUM TWIN SH IMPACT SERIES GA 195 ALUMINUM TWIN SH NI 12/31/2017 No Yes No N/A 4RST, 6RST, GD5S, GR5S, AR5S, ED5S VJINDCODE® W6 Garage Door PSF CONTINUOUS HEAD AND SILL 88 1/8X72 102 102 W6-16 PAN-21`153: 73, 75, 84A, 94, 42, 48, 42B, 48B, Steel Pan (min. 25 ga.) Double -Car (9'2" to 162" 05/21/2028 No Yes No +37 PSF/41 4RST, 6RST, GD5S, GR5S, AR5S, ED5S vide) WINDCODE® W6 Garage Door PSF Florida Department of Business & Professional Regulation Page 1 of 3 Florida Department of Business & Professional Regulation Page 1 of 1 Building Codes and Standards 1/92017 Building Codes and Standards 1/92017 Product Approval Application Detail Florida Department of Business & Professional Regulation Page 1 of 1 O Building Codes and Standards 1/92017 . t_ Product Approval Application Detail FL#15278-R4 Product Approval Application Detail FL#15288-R2 Code Entity or Date Date Date Pending Date Code Entity or Date Date Date Pending Date Type Versio Manufacturer Contact Eno ineer&License Validated By Validated Submitted FBC Approval Approved Status FL#15333-R2 Type Versio Manufacturer Contact Engineer & License Validated By Validated Submitted FBC Approval Approved Status Revision 2014 MI Windows and Doors BrentSiffinger Luis Roberto Lomas Steven M. Urich, PE 09/01/2015 08/31/2015 09/05/2015 10/16/2015 Approved Affirmation 2014 MI Windows and Doors Brent Sitinger Luis Roberto Lomas Steven M. Urich, PE 04/30/2015 04/30/2D15 05/10/2015 Approved Category: Windows SubCategory: Fixed (717) 365-3300 PE-62514 (717) 317-8454 bsitlinger@miwd.com Code Type Versio Manufacturer Entity or Contact Engineer & License Validated By Date Date Validated Submitted Date Pending FBC Approval Date Approved Status Category: Windows (717) 365-3300 PE-62514 (717) 317-8454 Compliance Method: Evaluation Report from a Revision 2014 MI Windows and Doors Brent Sitiinger Luis Roberto Lomas Steven M. Urich, PE 06/29l2015 06/19/2015 07/05/2015 08/19/2015 Approved r♦ r_ Subcategory: Horizontal Slider bsitlinger@miwd.com Florida Registered Architect or a Licensed Florida Category: Windows (717) 365-3300 PE-62514 (717) 317-8454 Compliance Method: Evaluation Report from a Professional Engineer Subcategory: Mullions bsitlinger@mwd.com Florida Registered Architect or a Licensed Florida Professional Engineer FL#15278-R4 Products Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida FL#15288-R2 Products Quality Assurance Approved for Use Approved for Use Impact Design Professional Engineer Sea # Product Model. Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure Quality Assurance Approved for Use Approved for Use Impact Design 4 SERIES GA 195 ALUMINUM PW SERIES GA 195 ALUMINUM PW NI 96X48 FIN 12/31/2017 No Yes No N/A FL#15333-R2 Products Sea # o Product Model. Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure 5 SERIES GA 195 ALUMINUM PW SERIES GA 195 ALUMINUM PW NI 72X72 12/31/2017 No Yes No N/A Quality Assurance Approved for Use Approved for Use Impact Design 1 SERIES G 19l, ALUMINUM HORIZONTAL SLIDER SERIES GA 198 ALUMINUM HORIZONTAL SLIDER 12l31/2017 No Yes No N/A FLANGE Sea # Product Model. Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure 2 SERIES GA 198 ALUMINUM HORIZONTAL SLIDER 72X54 SERIES GA 198 ALUMINUM HORIZONTAL SLIDER 12131/2017 No Yes No N/A 7 SERIES GA 195 ALUMINUM PW SERIES GA 195 ALUMINUM PW NI 96X48 12/31/2017 No Yes No N/A 7 1445, 5347 AND 5547 VERTICAL MULLION 1445, 5347 AND 5547 VERTICAL MULLION 12/3112017 No Yes Yes NIA 72X54 8 FLANGE SERIES GA 275 THERMALLY BROKEN ALUMINUM PW SERIES GA 275 THERMALLY BROKEN ALUMINUM 12/31/2017 No Yes No N/A 3 SERIES GA 198 ALUMINUM XOX HORIZONTAL SLIDER SERIES GA 198 ALUMINUM XOX HORIZONTAL 12/31/2017 No Yes No N/A PW NI 72X72 FIN A 1 SLIDER 108X48 9 SERIES GA 505 ALUMINUM PW SERIES GA 505 ALUMINUM PW NI 72X72 FIN 12/31/2017 No Yes No N/A VJ 4 SERIES GA 198 ALUMINUM XOX HORIZONTAL SLIDER SERIES GA 198 ALUMINUM XOX HORIZONTAL 12131/2017 No Yes No NIA SLIDER V O O L- 0- ry �i U CIO O Florida Department of Business & Professional Regulation Page 1 of Florida Department of Business & Professional Regulation Page 1 of 1 Florida Department of Business & Professional Regulation Page 1 of C Building Codes and Standards 1/92017 Building Codes and Standards 1192017 Building Codes and Standards 1/9/2017 Product Approval Application Detail Product Approval Application Detail Product Approval Application Detail (n FL#13192-R4 FL#15272-R1 FL#5444-R10 M I..I.J Code Entityor Date Date Date Pending Date Code Entityor Date Date Date Pendina Date Code Entityor Date Date Date Pending Date Cj Type Versio Manufacturer Contact Engineer&License Validated By Validated Submitted FBC: Approval Approved Status Type Versio Manufacturer Contact Engineer & License Validated By Validated Submitted FBC Approval Approved Status Type Versio Manufacturer Contact Engineer & License Validated By Validated Submitted FBC Approval Approved Status < Revision 2014 James Hardie Building Products, Inc. Pingsheng Zhu Ronald I. Ogawra John Southard, P.E. 08/26/2015 08/17/2015 09/07l2015 10/16/2015 Approved Revision 2014 Alside Nick Thom son Lyndon F. Schmidt, P.E. Ran J. King, P.E. p Y 02/23/2015 02/19/2015 03/01/2015 04/15/2015 Approved Pp Revision 2014 CertainTeed Corporation -Roofing P 9 Mark Harper Robert Nieminen John W. Knezevich PE � 12/14/2016 12f08/2016 12/15/2016 Pending FBC Approval 9 PP Category: Panel Walls (909) 349-2927 PE-24121 (352) 367-2526 Category: Panel Walls (330) 922-2389 PE-43409 (813) 767-6555 Category: Roofing (610) 651-5847 PE-59166 (954) 772-6224 SubCategory: Siding pingsheng.zhu@jameshar SubCategory: Soffits nthompson@alside.com SubCategory: Asphalt Shingles mark d.harner@saint-gob Compliance Method: Evaluation Report from a die.com Compliance Method: Evaluation Report from a Compliance Method: Evaluation Report from a ain.com Florida Registered Architect or a Licensed Florida Florida Registered Architect or a Licensed Florida Florida Registered Architect or a Licensed Florida S� Professional Engineer Professional Engineer Professional Engineer (_ FL#1 3192-R4 Products FL#15272-RI Products FL#5444-R10 Products 00 w C" Quality Assurance Approved for Use Approved for Use Impact Design # Product Model. Number Name Quality Assurance Approved for Use Approved Product Description Contract Expiration Date in HVHZ for Use Outside HVHZ Impact Resistant Design Pressure Quality Assurance Approved for Use Approved for Use Impact Sea # Product Model. Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure S, ea or Design 1 Cemplank Lap Siding fiber -cement lap siding 01/01/2018 Yes Yes NIA N/A 1 a. "2T" Soffit Vent or Solid Vinyl Soffit 12/31/2018 No Yes No N/A Sea # Product Model. Number or Name Product Descriotion Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure Q A 1 2 HardiePlank Lap Siding fiber -cement lap siding 01/01/2018 Yes Yes N/A N/A 2 b. "Alliance T4"a Soffit Vent or Solid Vinyl Soffit 12/3l/2018 No Yes No N/A 1 CertainTeed Asphalt Roofing Shingles 3-tab, 4-tab, strip (no -cut-outs), laminated and 07/03/2017 No Yes N/A N/A Z J architectural asphalt roof shingles Z Q J SHEET NO, PA 1 .1 N U) N O 3 � Q O Florida Department of Business & Professional Regulation Professional Page 1 of 1 (3) O Building Codes and Standards 1/92017 Ca n Florida Department of Business &Professional Regulation Pagel of Florida Department of Business &Professional Regulation Pagel oft n -4.—W -4 ��1♦♦ W Building Codes and Standards 1192017 Building Codes and Standards 2162017 Product Approval Application Detail U Ca U) Product Approval Application Detail Product Approval Application Detail FL#5219-R3 0 N O .Q _-2 FL#12328-R7 Products Coe Entity or Date Date Date Pending Date O L_ O Assurance Approved for Use Approved for Use Impact Design FL#21675-RO Tvpe Versio Manufacturer Contact Engineer&License ValidatedBv Validated Submitted FBC Approval Approved Status Quality Revision 2014 Thompson Architectural Metals Company, Inc. Scott Brown James L. Buckner Steven M. Urich, PE 05/01/2015 05/10/2015 06/23/2015 O Sea # Product Model. Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure Code Entity or Date Date Date Pending Date 04/29/2015 Approved cu. V 6 No. 15 UL Asphalt saturated organic felt 01/07/2019 No Yes N/A NIA Tvpe Versio Manufacturer Contact Engineer & License Validated By Validated Submitted FBC Approval Approved Status Category: Roofing (813) 248-3456 PE-31242 (717) 317-8454 � Qcom j New 2014 HomeGuard Building Products, Inc. John Cheslak ntertekTesting Services NA, Intertek Testing Services 02/01/2017 01/25/2017 02/03/2017 Subcategory: Roofing Accessories that are an Integral Part Roofing System flvalidation@yahoo.com ahoo (n Q Q Approved of the - M Compliance Method: Evaluation Report from a U) ly L Category: Roofing (904) 240-1382 Inc. NA, Inc. Florida Registered Architect or a Licensed Florida (n O Search Criteria Subcategory: Underlayments john.cheslak@hgwrap.00 (604) 520-3321 Professional Engineer !E Compliance Method: Evaluation Report from a m FL#5219-R3 Products Code Version: 2014 FL It. 12328 Product Evaluation Entity Application Type: ALL Product Manufacturer: ALL FL#21675-RO Products Quality Assurance Approved for Use Approved for Use Impact Design Category: ALL Subcategory: ALL Sea # Product Model. Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure Application Status: ALL Compliance Method: ALL Quality Assurance Approver! for Use Approved for Use Impact Design 1 1- "Flat Top Off Ridge Vent with Baffle for Tile" Minimum 26 Gauge Steel, Nominal 4', 6Ƈ, 12/31/2019 No Yes No NIA Quality Assurance Entity Contract Expired: ALL Product Model, Number or Name: ALL Sea # Product Model. Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure 8', or 10&439; Wide Off Ridge Vent Attached to Product Description: ALL Approved for use in HVHZ: ALL 1 ToughSkin Synthetic Underlayments ToughSkin 15, ToughSkin 20, ToughSkin 25, 01/01/2018 No Yes N/A N/A Wood Deck ToughSkin 30, ToughSkin 50 2 2- "Round Top Off Ridge Vent with Baffle for Minimum 26 Gauge Steel, Nominal 4',, 6', 12/31/2019 No Yes No N/A Approved for use outside HVHZ: ALL PP Impact Resistant: ALL P Tile" 8', or 10' Wide Off Ridge Vent Attached to Design Pressure: ALL Date From: ALL Wood Deck Date To: ALL 3 3- "Standard Off Ridge Vent with Permanent Baffle Minimum 26 Gauge Steel, Nominal 4', 6', 12I3112019 No Yes No NIA for Shingles" 8', or 10', Wide Off Ridge Vent Attached to Wood Deck Florida Department of Business & Professional Regulation Page 1 of 1 Florida Department of Business & Professional Regulation Pagel of 1 Building Codes and Standards 1/102017 Florida Department of Business &Professional Regulation Pagel of 1 LU Building Codes and Standards 1/92017 Product Approval Application Detail Building Codes and Standards g 1/102017 Product Approval Application Detail Product Approval Application Detail FL#17202-R1 FL#2075-R7 Code Entity or Date Date Date Pending Date FL#16588-R1 Tvpe Versio manufacturer Contact Engineer&License Validatedv Validated Submitted FBC Approval Approved Status Code Tvpe Versio Manufacturer Entity or Contact Engineer & License Validated By Date Date Validated Submitted Date Pending FBC Approval Date Approved Status Revision 2014 Lomanco, Inc Andrew Carter James L. Buckner, P.E. Steven M. Urich, PE 05101/2015 05/01/2015 05/10/2015 06/22/2015 Approved Code Versio Entity or Date Date Date Pending Date Category: Roofing (501) 982-6511 PE-31242 (717) 317-8454 Type Manufacturer Contact Engineer & License Validated By Validated Submitted FBC Approval Approved Status Affirmation 2014 Florida Metal Products Inc. Clark Jones Miami -Dade BCCO - EVL Miami -Dade BCCO - VAL 02/27l2015 02/27/2015 03l0912015 Approved Subcategory: RoofingAccessories that are an 9 ry' acarter@lomanco.com @ Affirmation 2014 O'Ha in Manufacturing, LLC 9 9' Gregory Daniels Miami -Dade BCCO - CER Ted Berman, PE 9 ry 06/17/2015 06/17/2015 06/25/2015 Approved PP Category: Roofing (904) 783-8400 (786) 315-2590 Integral Partof the Roofing System Category: Roofing (707) 872-3620 (305) 868-4707 Subcategory: Roofing Accessories that are an clark@flamco.com Compliance Method: Evaluation Report from a P P SubCategory: Roofing Accessories that are an g ry daniels oho in.com g @ g Integral Part of the Roofing System 9 9 Y Florida Registered Architect or a Licensed Florida o Integral Part of the Roofing System Compliance Method: Evaluation Report from a Professional Engineer Compliance Method: Certification Mark or Listing Product Evaluation Entity FL#17202-R1 Products FL#16588-R1 Products FL#2075-R7 Products nCD Quality Assurance Approved for Use Approved for Use act Design Quality Assurance Approved for Use Approved for Use Im pact Design Quality Assurance Approved for Use Approved for Use Impact Design Sea # Product Model. Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure Seq # Product Model. Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure Sea # Product Model, Number or Name ration Date in HVHZ Product Description Contract Expiration Outside HVHZ Resistant Pressure 1 Deck -Air- DA-4 Low Profile, Polypropylene Plastic, Roof Vent 07/10/2019 No Yes No +97.5/-97.5 1 0'Hagin's Cloaked Vent Tile Attic Ventilation Product for tile roofing applications 04/04/2018 Yes Yes N/A N/A 1 RV10 RV10 ALUMINUM RIDGE VENT 01131/2018 Yes Yes NIA N/A Mechanically Attached to Plywood Deck. 2 OmniRidge® PRO Vent PR04-N Molded Plastic, Roof Ridge Vent Mechanically 07/10/2019 No Yes No +N/A/-165 Attached to OSB or Plywood Deck. Florida Department of Business & Professional Regulation Page oft Building Codes and Standards 1/92017 Product Approval Application Detail FL#15076-R3 Florida Department of Business &Professional Regulation Page i of 3 Building Codes and Standards 1/92017 Code Entity or Date Date Date Pendina Date Tvpe Versio Manufacturer Contact Engineer & License Validated By Validated Submitted FBCApproval Approved Status O Product Approval Application Detail Revision 2014 Global Protection Products, LLC. Tim Robinson Walter A. Tillit Jr., P.E. John W. Knezevich, PE 05/06/2015 04/24/2015 05/11/2015 06/23/2015 Approved Florida Department of Business & Professional Regulation Page 1 of 1 Category: Shutters (954) 689-7545 PE-44167 (954) 772-6224 Building Codes and Standards 1/92017 M Subcategory: Storm Panels tim.robinson@gppent.com FL#7849-R9 Compliance Method: Evaluation Report from a Product Approval Application Detail Florida Registered Architect or a Licensed Florida Code Entity or Date Date Date Pending Date Professional Engineer Type Versio Manufacturer Contact Engineer & License Validated By Validated Submitted FBC Approval Approved Status FL#15088-R1 Revision 2014 Boral Roofing / MonierLfFetile Thomas Jammed ICC Evaluation Service, LLC Gary W. Walker 09/10/2015 08/25/2015 09/20/2015 Approved FL#15076-R3 Products Category: Roofing (602) 269-2288 (205) 854-0160 Quality Assurance Approved for Use Approved for Use Impact Design Code Entity or Date Date Date Pending Date SubCategory: Roofing Tiles thomas.jemmett@boral.co Sea # Product Model. Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure Tvpe Versio Manufacturer Contact Engineer & License Validated By Validated Submitted FBC Approval Approved Status Compliance Method: Evaluation Report from a m 1 20 Gage Galvanized Steel Storm Panels/HVHZ Corrugated Galvanized Steel Storm Panels retained 12/31/2017 Yes Yes Yes N/A Revision 2014 Globai Protection Products, LLC. Tim Robinson Walter A. Tillit Jr., P.E. John W. Knezevich, PE 04/27/2015 04/24/2015 05/03/2015 06/23/2015 Approved Product Evaluation Entity or not by tracks to provide hurricane protection. Category: Shutters (954) 689-7545 PE-44167 (954) 772-6224 2 24 Gage Galvanized Steel Storm Panels/NHVHZ Corrugated Galvanized Steel Storm Panels retained 12131/2017 No Yes Yes NIA SubCategory: Fabric Storm Panel tim.robinson@gppent.com FL#7849-R9 Products or not bytracks to provide hurricane protection. Compliance Method: Evaluation Report from a Quality Assurance Approved for Use Approved for Use Impact Design Florida Registered Architect or a Licensed Florida Sea # Product Model. Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure FL#15076-R4 Professional Engineer 13 Saxony 00 - Shake, Slate & Split Shake Flat Profile -Stockton 12/312018 No Yes N/A N/A Code Enti or Date Date Date Pending Date FL#15088-R1 Products 14 Saxony 900 -Country Slate, Shake & Slate 9 Flay Profile -Henderson 12/31/12018 No Yes N/A N/A T e Versio �� Manufacturer Contact Engineer & License Validated By Validated Submitted FBC Approval Approved Status Quality Assurance Approved for Use Approved for Use Impact Design 15 Saxony 900 - Country Slate, Shake, Slate & Split Flat Profile - Lake Wales 12/31/2018 No Yes N/A N/A Revision 2014 Global Protection Products, LLC. Tim Robinson Walter A. Tillit Jr., P.E. John W. Knezevich, PE 12/21/2016 12/2112016 Validated Sea # Product Model. Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure Shake Category: Shutters (954) 689-7545 PE-44167 (954) 772-6224 1 GPP FABRIC SHUTTER -SERIES 2000 Coated Polyethylene Fabric Panels retained by tracks 12/3112017 No Yes Yes N/A 16 Saxony 900 - Hartford Slate, Split Old English Thatch, Flat Profile - Stockton 12/31/2018 No Yes N/A NIA Subcategory: Storm Panels tim.robinson@gppent.com or direct mounted to provide hurricane protection. Shake, Slate, Country Slate Compliance Method: Evaluation Report from a 24 Villa 900 Medium Profile - Lake Wales 12/31/2018 No Yes N/A N/A Florida Registered Architect or a Licensed Florida 25 Villa 900 Medium Profile - Denver 1213112018 No Yes Yes N/A N/A N/A N/A Professional Engineer I^ ` (� 26 Villa 900 Medium Profile - Stockton 12/3l/2018 No FL#15076-R4 Products Quality Assurance Approved for Use Approved for Use I pact Design U) Sea # Product Model. Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure 1 20 Gage Galvanized Steel Storm Panels/HVHZ Corrugated Galvanized Steel Storm Panels retained 12/31/2017 Yes Yes Yes N/A 2 24 Gage Galvanized Steel Storm Panels/NHVHZ or not by tracks to provide hurricane protection. Corrugated Galvanized Steel Storm Panels retained 12/31/2017 No Yes Yes N/A or not by tracks to provide hurricane protection. 0 LL CL 0_ ry U Florida Department of Business & Professional Regulation Page 1 of 1 0 Building Codes and Standards 1/92017 Product Approval Application Detail Florida Department of Business & Professional Regulation Pagel of 2 Florida Department of Business & Professional Regulation Page 1 of 1 Building Codes and Standards 1/92017 Building Codes and Standards 1/92017 FL#12856-R5 Product Approval Application Detail Product Approval Application Detail U) Code Entity or Date Date Date Pending Date Type Versio Manufacturer Contact Engineer & License Validated By Validated Submitted FBCApproval Approved Status FL#17869-RO FL#1999-R5 M�y0 Revision 2014 Town and Country Industries, Tom Johnston Frank]. Bennardo ORLANDO L. BLANCO, 04/29/2015 04/28/2015 05/04/2015 06/22/2015 Approved I.. Category: Shutters SubCategory: Storm Panels (954) 493-8551 PE-0046549 P.E. tomj@tc-alum.com (305)510-8531 Code Type Versio Manufacturer Entity or Contact Engineer & License Validated By Date Date Validated Submitted Date Pending FBC Approval Date Approved Status Code Tvpe Versio Manufacturer Entity or Contact Engineer&License Validated By Date Date Validated Submitted Date Pending FBC Approval Date Approved Status Compliance Method: Evaluation Report from a New 2014 All American Shutters and Glass Mike Barbieri Frank L. Bennardo, RE Jorge A. Pomerantz, P.E. 07/03/2015 07/03/2015 07/10/2015 08/18/2015 Approved Revision 2014 ITW Building Components Group Inc. / Paslode Stuart Lewis ICC Evaluation Service, LLC William M. Ranieri, PE 03/25/2015 03/20/2015 03/29/2015 Approved ^^ Florida Registered Architect or a Licensed Florida Category: Shutters (561) 712-9882 PE-0046549 (954) 394-8521 Category: Structural Components (847) 918-6473 (407) 681-1917 11 Professional Engineer SubCategory: Storm Panels mikeb@allamericanshutte SubCategory: Truss Plates slewis@alpineitw.com FL#12856-R5 Products Compliance Method: Evaluation Report from a rs.com Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Product Evaluation Entity L� Quality Assurance Approved for Use Approved for Use Impact Design Professional Engineer FL#1999-R5 Products Seq # Product Model. Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure 1 0.050& q uot; Aluminum Storm Panel 0.050& uot; Aluminum Storm Panel with Optional 12/3112018 q p No Yes Yes N/A FL#17869-RO Products Quality Assurance Approved for Use Approved for Use Impact Design W Clear Panels 12131/28 No Yes Yes +54/-54 Quality Assurance Expiration Date Approved for Use Approved for Use HVHZ Impact Resistant Design Sea # Product Model, Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure 2 "Safety Edge" Storm Panels "Safety Edge"a Storm Panels, 28ga 01 (0.018"") Steel, 0.022" Alum (Pert Seq # 1 Product Model, Number or Name 22ga, 24ga Steel Panels Product Description Contract in HVHZ Outside 22ga, 24ga Steel Storm Panels 12/31/2017 No Yes Yes Pressure N/A 1 2 ITW BCG Higher Strength (H & S) ITW BCG Hinge Plate Metal Connector Plate 12/31/2020 Metal Connector Plate 12/31/2020 Yes Yes Yes Yes N/A N/A N/A N/A Q and Non -Pert) Clear Polycarb (Full and Halt) 3 ITW BCG Trulox Metal Connector Plate 12/31/2020 Yes Yes N/A N/A Z 3 24ga Steel Storm Panel 24ga (0.0232"a) Steel Storm Panel with Optional 12131/2018 No Yes Yes +100/-100 4 ITW BCG Wave Metal Connector Plate 12/31/2020 Yes Yes NIA N/A Clear Panels z 4 Aluminum Hinged Storm Panel .050" Aluminum Non -Porous Hinged Storm 1213l/2018 Yes Yes Yes N/A Panel Q J d SHEET NO. PA 1.2- N Cn ll oO O Florida Department of Business &Professional Regulation Page 1 of 1 Florida Department of Business &Professional Regulation Page 1 of 1 a) }+ ( U)(D Building Codes and Standards 1/92017 Building Codes and Standards 1/92017 Florida Department of Business &Professional Regulation Page 1 of 1 C � Co Building Codes and Standards 1,920,7 Q) � C.)-0 Product Approval Application Detail Product Approval Application Detail a) O O .L � Product Approval Application Detail O 0—FLtkL197-R5 FL#1644-R4 0 Code Entityor Date Date Date Pending Date Code Entityor Date Date Date Pending Date FL#1645-R4 CU O O 44— M Tope Versio Manufacturer Contact Engineer & License Validated Bv Validated Submitted FBC Approval Approved Status Type Versio Manufacturer Contact Engineer & License Validated By Validated Submitted FBCApproval Approved Status Code Entity or Date Date Date Pending Date Q Revision 2014 MiTek Industries, Inc. David Wert ICC Evaluation Service, LLC ICC Evaluation Service, 06/30/2015 06/11/2015 07/05/2015 Approved Revision 2014 Boise Engineered Wood Products Robert Taylor ICC Evaluation Service, LLC APA - The Engineered 05/27/2015 05/06/2015 06/02/2015 Approved Type Versio Manufacturer Contact Engineer & License Validated By Validated Submitted FBC Approval Approved Status .� O Category: Structural Components g ry: p (314) 851-7480 LLC. Category: Structural Components (541) 826-0200 Wood Association Revision 2014 Boise Engineered Wood Products Robert Taylor ICC Evaluation Service, LLC APA -The Engineered 05/27/2015 05/06/2015 06/02/2015 Approved � Q) L t� L Subcategory: Truss Plates dwert@mii.com (205) 599-9800 Subcategory: Engineered Lumber roberttaylor@bc.com (253) 620-7467 Category: Structural Components (541) 826-0200 Wood Association U) O Co Compliance Method: Evaluation Report from a Compliance Method: Evaluation Report from a Subcategory: Engineered Lumber roberttaylor@bc.com (253) 620-7467 (� 4— Product Evaluation Entity Product Evaluation Entity Compliance Method: Evaluation Report from a FL#2197-R5 Products FL#1644-R4 Products Product Evaluation Entity Quality Assurance Approved for Use Approved for Use Impact Design Quality Assurance Approved for Use Approved for Use Impact Design FL#1645-R4 Products Seq # Product Model, Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure Seq # Product Model, Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure Quality Assurance Approved for Use Approved for Use Impact Desicin 1 M18SHS 18 ga. super high strength truss connector plate 12/31/2017 Yes Yes N/A N/A 1 Versa -Lam Laminated Veneer Lumber 01101/2035 No Yes NIA N/A Seq Product Model. Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure 2 MII 16 16 ga. truss connector plate 12131/2017 Yes Yes N/A N/A 1 AJS Joists Wood "l" Joists 01/01/2035 No Yes N/A N/A 3 MT18HS 18 ga. high strength truss connector plate 12/31/2017 Yes Yes N/A N/A 4 MT20 20 ga. truss connector plate 12/31/2017 Yes Yes N/A N/A 5 MT20HS 20 ga. high strength truss connector plate 12/312017 Yes Yes N/A NIA Search Criteria Florida Department of Business & Professional Regulation Page 1 of 1 Building Codes and Standards 1/92017 Product Approval Application Detail Florida Department of Business & Professional Regulation Page 1 of 1 Building Codes and Standards 1/92017 FL#6527-R6 Florida Department of Business &Professional Regulation Pege1 oft Code Entityor Date Date Date Pending Date Product Approval Application Detail Type Versio Manufacturer Contact Engineer& License Validated By Validated Submitted FBC Approval Approved Status Building Codes and Standards 1/92017 Revision 2014 Weyerhaeuser Jim Anderson ICC Evaluation Service, LLC James A. Rothman, P.E. 07/06/2015 05/12/2015 07/30/2015 Approved FL#158-R7 Category: Structural Components (253) 924-4084 (608) 839-1344 Product Approval Application Detail Subcategory: ry:En Engineered Lumber jim.anderson2@weyerhae Code Entitygor Date Date Date Pending Date Compliance Method: Evaluation Report from a user.com Tope Versio Manufacturer Contact Engineer& License Validated By Validated Submitted FBC Approval Approved Status Product Evaluation Entity Revision 2014 CAST-CRETE USA, Inc. Craig Parrino Miami -Dade BCCO - CER Miami -Dade BCCO - VAL 03/16/2015 02/24/2015 03/18/2015 Approved FL#1630-R8 FL#6527-R6 Products Category: Structural Components 9 ry� P 813 621-4641 ( ) (786) 315-2590 Code Entity or Date Date Date Pending Date Subcategory: Products Introduced as a Result of cparrino@castcrete.com Type Versio Manufacturer Contact Engineer & License Validated By Validated Submitted FBC Approval Approved Status Quality Assurance Approved for Use Approved for Use Impact Design New Technology Revision 2014 Weyerhaeuser Jim Anderson ICC Evaluation Service, LLC James A. Rothman, P.E. 07/06/2015 05/1212015 07/30/2015 Approved Seq # Product Model. Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure Compliance Method: Certification Mark or Listing Category: Structural Components (253) 924-4084 (608) 839-1344 1 il-evel Rim Board Structural Composite Lumber or Oriented Strand 03/31/2017 No Yes N/A N/A FL#158-R7 Products Subcategory: Engineered Lumber jim.anderson2@weyerhae 2 Microllam LVL board Rim Board Laminated Veneer Lumber 03/3112017 No Yes N/A N/A Quality Assurance Approved for Use Approved for Use Impact Design Compliance Method: Evaluation Report from a user.com 3 Parallam PSL Parallel Strand Lumber 03/31/2017 No Yes N/A N/A Seq # Product Model, Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure Product Evaluation Entity 4 TimberStrand LSL Laminated Strand Lumber 03/31/2017 No Yes NIA N/A 1 High Strength Concrete Lintels 4, 6, 8, and 12 inch wide lintels 05/21/2016 Yes Yes N/A NIA FL#1630-R8 Products Quality Assurance Approved for Use Approved for Use Impact Design FL#6527-R7 FL#158-R8 Sea # Product Model, Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure Code Entity o Date Date Date Pending Date Code Entity o Date Date Date Pending Date 1 TJI 110 Prefabricated Wood ]-joist 03/31/2017 No Yes N/A N/A Type Versio Manufacturer Contact Engineer & License Validated By Validated Submitted FBC Approval Approved Status Type Versio Manufacturer Contact Engineer & License Validated By Validated Submitted FBC Approval Approved Status 2 TJI 210 Prefabricated Wood ]-joist 03/31/2017 No Yes N/A N/A Revision 2014 Weyerhaeuser Jim Anderson ICC Evaluation Service, LLC James A. Rothman, P.E. 10/31/2016 10/25/2016 11/05/2016 Approved Revision 2014 CAST-CRETE USA, Inc. Craig Parrino Miami -Dade BCCO - CER Miami -Dade BCCO - VAL 05/06/2016 04/29/2016 05/06/2016 Approved 3 4 TJI 230 TJI 360 Prefabricated Wood ]-joist 03/312017 Prefabricated Wood I -joist 03/31/2017 No No Yes Yes N/A N/A N/A N/A Category: Structural Components (253) 924-4084 (608) 839-1344 Category: Structural Components (813) 621-4641 (786) 315-2590 5 TJI 560 Prefabricated Wood ]-joist 03131l2017 No Yes N/A N/A SubCt aegory: Engineered Lumber jim.anderson2@weerhae y SubCate o g ry: Products Introduced as a Result of cparrino@castcrete.cem 6 TJI/560D Prefabricated Wood ]-joist 03/3112017 No Yes N/A N/A Compliance Method: Evaluation Report from a user.com New Technology Product Evaluation Entity Compliance Method: Certification Mark or Listing FL#6527-R7 Products FL#158-RS Products Quality Assurance Approved for Use Approved for Use Impact Desian Quality Assurance Approved for Use Approved for Use impact Design Sea # Product Model Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure Sea # Product Model. Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure 1 Microllam LVL Laminated Veneer Lumber 03/31/2017 No Yes N/A N/A 1 High Strength Concrete Lintels 4, 6, 8, and 12 inch wide lintels 05/21/2017 Yes Yes NIA N/A 2 Parallam PSL Parallel Strand Lumber 03/31/2017 No Yes N/A N/A 3 TimberStrand LSL Laminated Strand Lumber 03/31/2017 No Yes N/A N/A 4 TJ Rim Board Structural Composite Lumber or Oriented Strand 03/31/2017 No Yes N/A N/A board Rim Board 5 Weyerhaeuser Rim Board Oriented Strand Board Rim Board 03/31/2017 No Yes N/A N/A Florida Department of Business & Professional Regulation Pagel oft Florida Department of Business & Professional Regulation Page 1 of 1 Building Codes and Standards 1/9/2017 Florida Department of Business & Professional Regulation Page 1 of 1 O Building Codes and Standards 1/92017 Product Approval Application Detail Building Codes and Standards 1/92017 • o +� Product Approval Application Detail Product Approval Application Detail FL#5450-R5 FL#1774-R4 Code Entity or Date Date Date Pending Date FL#11383-R4 Type Versio Manufacturer Contact Engineer& License Validated By Validated Submitted FBC Approval Approved Status Code Entityor Date Date Date Pending Date Revision 2014 Powers Steel Inc. william powers Steven W. Schaub SAMUEL A. 03/26/2015 03/23/2015 03/30/2015 06/23/2015 Approved Code Entity or Date Date Date Pending Date Type Versio Manufacturer Contact Engineer& License Validated By Validated Submitted FBC Approval Approved Status Category: Structural Components (602) 437-1160 PE-60509 GREENBERG, RE,Tvpe Versio Manufacturer Contact Engineer & License Validated By Validated Submitted FBC Approval Approved Status Revision 2014 Commercial Concrete Products,lnc. Robert Gillis THUY H. HUYNH Florida Engineering 07/03/2015 06/24/2015 08/20/2015 08/26/2015 Approved SubCategory: Products Introduced as a Result of bill@powerssteel.com (813) 645-0166 Revision 2014 Powers Steel Inc. William powers Steven Schaub SAMUEL A. 03/26/2015 03/23/2015 03/30/2015 06/22/2015 Approved Category: Structural Components (813) 659-3707 PE-60122 Solutions New Technology Category: Structural Components 9 ry� p 602 4 ( ) 37-1160 PE-60509 GREENBERG, RE, SubCate o Products Introduced as a Result of 9 ry recast ator ahoo.com (352 588-5311 p g @y ) Compliance Method: Evaluation Report from a p P SubCategory: Products Introduced as a Result of bill@powerssteel.com 813 645-0166 ( ) New Technology Florida Registered Architect or a Licensed Florida New Technology Compliance Method: Evaluation Report from a Professional Engineer Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Florida Registered Architect or a Licensed Florida Professional Engineer FL#5450-R5 Products Professional Engineer FL#1774-R4 Products Quality Assurance Approved for Use Approved for Use Impact Design FL#11383-R4 Products Sea # Product Model. Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure Quality Assurance Approved for Use Approved for Use Impact _� Design r. 1 PSboxBLT, PSboxBLT{5-5/8) Powers Steel lintels are field assembled lintels 01/272017 No Yes N/A N/A Quality Assurance Approved for Use Approved for Use I act —�— Desi n —� Sea # Product Model Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure consisting of preformed steel lintels combined with Se # Product Model, Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure 1 Quality Precast or Commercial Concrete Products Precast and Prestressed Concrete Lintels 05/25/2024 No Yes N/A N/A concrete masonry units, grout, and steel reinforcing 1 PowerBOX8 Lintels Powers Steel Lintels are field assembled consisting 01101/2017 No Yes NIA NIA bars. of preformed steel lintels combined with brick or concrete masonry units, grout, and steel reinforcing Q) bars. U) U) O _O CL U O L cn � m Q U m W� ¢ z z J a SHEET NO. PA 1.3