Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
5044 9th St
6.24kW SOLAR ARRAY PLANS FOR MICHAEL VAN SANT 5044 9TH ST ZEPHYRH LLS, FLORIDA 33542 PROJECT DESCRIPTION: 16 MODULES - TRINA: TSPGa-DE09.05 390 16 INVERTERS - ENPHASE: IQ8PLUS-72-2-US GOVERNING CODES: 2023 FLORIDA PLUMBING CODE, 8TH EDITION 2023 FLORIDA BUILDING CODE, 8TH EDITION 2023 FLORIDA MECHANICAL CODE, 8TH EDITION NEC 2020 NFPA 1 2021 DISCONNECT MODULE ROOF LAYOUT NTS *: • N0 7479 "33 ST >� WINDSPEED DESIGN DATA PER FBCR 2023 WIND SPEED 140 MPH RISK CATEGORY II EXPOSURE C GUST FACTOR ±0.18 "A" DIMENSION 3 Ft ROOF PRESSURE FOR COMPONENTS AND CLADDING GABLE ROOF ZONE 1 +15.8 PSF -39.1 PSF ZONE 2E +15.8 PSF -39.1 PSF ZONE 2N +15.8 PSF -57.0 PSF ZONE 2R +15.8 PSF -57.0 PSF ZONE 3E +15.8 PSF -57.0 PSF HIP ROOF ZONE 1 +15.8 PSF -35.5 PSF ZONE 2R +15.8 PSF -46.3 PSF ZONE 2E +15.8 PSF -49.8 PSF ZONE 3 +15.8 PSF -49.8 PSF No pwoft +¢$, GENERAL NOTES: 1. THIS IS TO CERTIFY THAT TO THE BEST OF MY KNOWLEDGE AND BELIEF, THESE PLANS CONFORM WITH FLORIDA BUILDING CODE 2023 WITH ALL SUPPLEMENTS AND ADDITIONS. 2. ALL PRODUCTS TO BE INSTALLED PER MANUFACTURER'S WRITTEN SPECIFICATIONS. I, ANDREW D. HALL PEA 87479 AN ENGINEER LICENSED PURSUANT TO CHAPTER 471, CERTIFY THAT THE PV ELECTRICAL SYSTEM AND ELECTRICAL COMPONENTS ARE DESIGNED AND APPROVED USING THE STANDARDS CONTAINED IN THE MOST RECENT VERSION OF THE FBC, FBC 107. DRAWING INDEX: S-1 COVER S-2 ARRAY LAYOUT & DETAILS S-3 ELECTRICAL S-4 NOTES S-5 SPECIFICATIONS S-6 SPECIFICATIONS S-7 SPECIFICATIONS S-8 SPECIFICATIONS S-9 SPECIFICATIONS V v, 2 Z o C o co O J 00 woJ wC--)=� H Lr) r CV Z [V Z M d W N �. w Z O or d H Z o � o U uj � Q � _ U h- w �- o m C) cn z W W w w o o > � a. CD M. NO. S-1 T- 1 ,aA4fIAIIIps- EVEREST EC CLIP (TYP) 3/8"-16 X 3/4" HEX HEAD BOLT 3/8" - 16 FLANGE NUT PV MODULE \ K2 SPLICE FOOT X/XL EXISTING ROOF TRUSS EVEREST IMC CLIP EVEREST 1 /2" PLYWOOD EXISTING UNDERLAYMENT (2) 5/16" DIA SS LAG SCREW 2-1/2" EMBED MIN. TYPICAL SHINGLE ROOF ATTACHMENT NTS K2 SPLICE FOOT X/XL (TYP) 48" MAX. O.C. (2) 5/16" DIA SS LAG SCREW 2- K2 SPLICE FOOT X/X (TYP) EVEREST IMC CLIP (TYP) I V I Y I L 1 1 NTS TRINA: TSM-DE09.05 390 (TYP) EVEREST IMC CLIP (TYP) TRINA: TSM-DE09.05 390 (TYP) T-11 Li K2 SPLICE FOOT X/XL (TYP) EVEREST IMC CLIP (TYP) TYPICAL SHINGLE ROOF LAYOUT "'L EVEREST CROSSRAIL 48-X (TYP) EVEREST CROSSRAIL 48-X (TYP) EVEREST EC CLIP (TYP) W Elfz �o =DL- Z U ¢ W � W W '�'KEVEREST EC CLIP (TYP) °°° * fC874 7g �Ir ems•..<o J J Q 2 0 uj U W 2 U N M m N Z N o 3 w z M N v kn z o o ¢ ono Q_ ZWo� � d- W o = UJ = M N Z W N" W z 7 o CJ � H Z D Z CD Z r- 48 U O� F - 0 4i Z U or cii U to �- w p p DWG. NO. C -2 N L2 L1 METER 0 N I L2 L1 NEUTRAL GROUND AC PANEL 100 AMP/240V #6 THWN-2 3/4" EMT, FMC, FOR EXTERIOR APPLICATION USE PVC OR LFMC/LFNMC CONDUIT #10 THWN-2 3!4" EMT, FMC, FOR EXTERIOR LOCKABLE FUSED APPLCATION USE PVC PV AC DISCONNECT OR LFMC/LFNMC CONDUIT 60A 240V 2-POLE #10 THWN-2 30A RK-1 FUSE 3/4" EMT, FMC, FOR EXTERIOR APPLCATION USE PVC OR LFMC CONDUIT NEUTRAL BONDED TO GROUND PER NEC 250.142(A)(3) GROUND GROU ENPHASE IQ COMBINER 4 W/ (2) 20 AMP BREAKER N• •m I', ENPHASE Q CABLE Q-12-10-240 (TYP) NOTE: ALL INVERTERS ARE EQUIPPED W/ INTERNAL RAPID SHUTDOWN SYSTEM PER NEC 690.12 G ____j J I SOLADECK COMBINER BOX #6 THWN-2 L60OV/ NON -FUSED OR SOLTECTION RESIDENTIAL TRANSITION BOX GEC BOND AT RACKING SYSTEM (SEE NOTE #2) AC DC NO. 8 AC AC DCN DC N0, 1 NO. 8 I 1 1 ENPHASE Q CABLE Q-12-10-240 (TYP) TRINA: TSM-DE09.05 390 W/ ENPHASE IQ8PLUS-72-2-US INVERTER (TYP) EVEREST CROSSRAIL 48-X (TYP) NOTE: ALL STRINGS TO HAVE TERMINATORS & SEALING CAPS INSTALLED PER MANUFACTURER'S SPECIFICATIONS N 0 m N m N � CD w z 3 m 0 N v J J V) M z cn o o .z O J O Q Zw�� W O 1 W U = M 1-4 N Z z"'�� W W z D o C3' a H z D S-3 ..euoe®ef• MODULE SPECIFICATION MODULE MAKE TRINA SOLAR MODULE MODEL TSM-DE09.05 390 FSEC CERTIFICATION # PMAX (STC) 390 W VOC (STC) 40.80 V VMPP (STC) 33.80 V ISC (STC) 12.14 A IMPP (STC) 11.54 A NOCT 43 C TC ISC 0.0400 %/K TC VOC —0.2500 %/K TC PMPP —0.3400 %/K OPERATING TEMP. —40—+85 C SAFETY LABELS AND MARKINGS GENERAL NOTES: 1. EQUIPMENT SUCH AS INVERTERS AND SOLAR MODULES HAVE PRE -APPLIED LABELS FOUND HEREIN SHALL BE APPLIED TO SUCH EQUIPMENT FOR INFORMATIONAL PURPOSES. 2. LABELS AND MARKINGS SHALL BE APPLIED TO COMPONENTS IN ACCORDANCE WITH THE CURRENTLY ADOPTED EDITION OF NEC. 3. ALL REQUIRED PRODUCT SAFETY AND WARNING SIGNAGE SHALL BE UV RESISTANT OUTDOOR -RATED LAMINATED VINYL IN ACCORDANCE WITH ANSI Z535.4-2011. 4. ALL LABELS SHALL BE REFLECTIVE PER NFPA 11.12 SAFETY LABELS AND MARKINGS LEGEND A. LOCATION OF SERVICE DISCONNECTING MEANS. APPLY TO MAIN SERVICE DISCONNECTING MEANS AND PV DISCONNECTING MEANS AT POCC. MAIN SERVICE DISCONNECT MARKING A LABEL SHALL BE PERMANENTLY AFFIXED TO THE MAIN SERVICE DISCONNECT PANEL SERVING ALTERNATING CURRENT (AC) AND DIRECT CURRENT (DC) PHOTOVOLTAIC SYSTEMS. THE LABEL SHALL BE RED WITH WHITE CAPITAL LETTERS AT LEAST 3/4 IN. IN HEIGHT AND IN A NONSERIF FONT, TO READ: "WARNING: PHOTOVOLTAIC POWER SOURCE." THE MATERIALS USED FOR THE LABEL SHALL BE REFLECTIVE, WEATHER RESISTANT, AND SUITABLE FOR THE ENVIRONMENT. RAPID SHUTDOWN MEANS MARKING A PERMANENT LABEL SHALL BE AFFIXED ADJACENT TO THE CIRCUIT DISCONNECTING MEANS SERVING AC AND DC PHOTOVOLTAIC SYSTEMS. THE LABEL SHALL HAVE BE REFLECTIVE WITH ALL LETTERS CAPITALIZED AND HAVING A MINIMUM HEIGHT OF 3/8", IN A BLACK ON YELLOW BACKGROUND FOR THE FIRST LINE, THE REAMING TEXT MUST BE UPPERCASE AT LEAST 3/16" HIGH IN BLACK ON WHITE BACKGROUND. THE LABEL SHALL BE CONSTRUCTED OF DURABLE ADHESIVE MATERIAL OR OTHER APPROVED MATERIAL. INVERTER SPECIFICATION _ INVERTER MAKE ENPHASE INVERTER MODEL IQ8PLUS-72-2-US MAX AC POWER OUTPUT 300 VA MAX. INPUT VOLTAGE 60 V NOM. DC VOLTAGE @ 240V 240 V NOM. AC VOLTAGE 25-58 V MAX. CONTINUOUS OUTPUT CURRENT 1.21 A MAX. DC CURRENT 15.0 A MAX. DC POWER (STC) 440 W CEC EFFICIENCY 97 N AN EMERGENCY CONTACT -800-351-3430 SOLAR PHOTOVOLTAIC SYSTEM Ai -WARNING- AUTHORIZED PERSONNEL ONLY RATED AC CURRENT: 24.2A NOMINAL AC VOLTAGE: 240V LOCATION: MAIN PV PANEL PHOTOVOLTAIC DISCONNECT Ai -WARNING- ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS. TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION. LOCATION: AC DISCONNECT(S) NOTES: 1. ALL ASPECTS OF THE ELECTRICAL WORK REQUIRED TO COMPLETE THE PROJECT REPRESENTED IN THIS DOCUMENT SHALL COMPLY WITH THE MANUFACTURERS RECOMMENDATIONS/SPECIFICATIONS AND ALL CODES, STATUES AND STANDARDS ADOPTED BY THE STATE AND THE LOCAL AUTHORITY HAVING JURISDICTION, 2. ALL COMPONENTS MUST BE GROUNDED PER NEC 690.43. 3. ALL EQUIPMENT SHALL BE LISTED PER NEC 690.4(D). 4. THE INFORMATION PROVIDED IN THESE DOCUMENTS IS NOT EXHAUSTIVE. IT REMAINS THE CONTRACTORS RESPONSIBILITY TO ACHIEVE THE PROPOSED INSTALLATION, IN FULL EXERCISE OF AND COMPLIANCE WITH THE ITEMS IDENTIFIED IN NOTE 1.. 5. PER NEC 690.17 PROVIDE A WARNING SIGN AT ALL LOCATIONS WHERE TERMINALS OF THE DISCONNECTING MEANS BE ENERGIZED IN THE OPEN POSITIONS. SIGN SHALL READ "WARNING —ELECTRIC SHOCK HAZARD — DO NOT TOUCH TERMINALS — TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION OR EQUIVALENT. 6. PER NEC 705.10, PROVIDE A PERMANENT PLAQUE OR DIRECTORY SHOWING ALL ELECTRIC POWER SOURCES ON THE PREMISES AT SERVICE ENTRANCE. 7. INTERCONNECTION METHOD SHALL COMPLY WITH NEC 705.12. 8, PV METER MAY OR MAY NOT BE REQUIRED BY THE AHJ AND/OR UTILITY FOR INTERCONNECTION. 9. CONDUCTOR SIZING OF THIS DESIGN IS BASED ON RACEWAYS LOCATED OUTSIDE ATTICS OR NOT EXPOSED TO DIRECT SUNLIGHT. WHERE TWO DIFFERENT AMPACITIES APPLY TO ADJACENT PORTIONS OF A CIRCUIT, THE HIGHER AMPACITY SHALL BE PERMITTED TO BE USED BEYOND THE POINT OF TRANSITION, A DISTANCE EQUAL TO 3.OM (10ft) OR 10 PERCENT OF THE CIRCUIT LENGTH FIGURED AT THE HIGHER AMPACITY, WHICH EVER IS LESS. NEC 310.15 (B)(2) 10.ALL CONDUCTORS AND RACEWAYS SHALL BE SUPPORTED ON INTERVALS AND BY METHODS REQUIRED BY THE NEC. 11. LINE TAPS TO BE MADE WITH ILSCO PBTD-3-3/0 NIMBUS INSULATED ALUMINUM MULTI —TAP CONNECTOR. 12. GFI BUILT IN TO ALL INVERTERS. SAFETY LABELS Ai -WARNING- ELECTRIC SHOCK HAZARD. THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED AUTHORIZED PERSONNEL ONLY LOCATION: DISCONNECTS, INVERTERS, JUNCTION BOXES, OTHER ENCLOSES HOLDING DC CONDUCTORS EMERGENCY RESPONDER: THIS SOLAR PV SYSTEM IS EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION PvRZf1ECIPoCs TO SHUT DOWN LAj_ ENTIRE PV SYSTEM 9 V N 2 z o O H O Q O J z CIO wowLo W U = M Lo c�NZ N WMN" W z O z S-4 M M i N N 0 m 0 V) Lu O Z :,�m9mmmaaasPs. n!x,r it ce BA:CKSHEETMON©CW STALLINEi ODLILE A-A 6c.EL.9,YiC.�E £z3rT'F. (STC) Peak Power Watts-Pb (Wp)' 380 Power Tolerance-Pw x(W) AL i..._ e-m4.a PI y 9 Y 1 Graundingitole a ncatnitot r 1 CURIJES O. PV mwu4_. 400 350 ��x1 BackVlew 1ocmN/m>[ 4 300 Spa E k Siiic n6eaiant 250 /i 80ow/m 2L'b % 60011/ it / 400W/m' 100 Frame Frame So /// . ca'AWi 0 in 20 M 40 50 154 Voltage(V) 3850395 400 ...._............. ..............-. ..._,_, _ Maximum PdwerCmredit-k�(A) n,38 U46 21.54 11.62 -1170 Short Circuit Current-Isc.(A) 12,00 12.07 iZ.14 12.21 12:28 SrekMianee Y000tV/mZ CeO Temperame LS°G FIrMasz RMIS �Measurlrq ldetMKe:x346. ELECTRICAL TRICAL DATA (NOCT) Maximum Power PMnx(Wp) 286 290 294 298 302 Maxi mum Power Voltage-V—(V) 3L4 31.6 31,.8 319: 32-1 r.H'H1b_?!t Solar Cells Monocrystallme 2Dmm PERC No,ofcells 120cells quta E3jm8nK�igns/ %;, �1754*1b9>F30mm (6906*4315x110 nrnes) �//j�,. Weight 21,0 kg (46.3lb) ±) 5S ,l �. 92mm OJ,3 mL14p5),,p9fi rsn-iibwe.Ae0.2tt1i{ f4Vc41ytr7eJU .. .,� EjrcypsulantrmtErial EVA/POE - Back Wh(te ,MAN Frame _ 3anm(118inches) !Anodized Aluminium Alloy P 68 ra ed Cables Photo•;nitaic Technology Cable 4.0mma(0.006 inches), Ler:yth 1100/1100mm(43.31/43.31 inches) Cbnnechg MC4 EU(32 4 r t !', �'' y-; y, : .. �..._ -emu g, Fire Type -; TYpelorTypeZ TEMPERATURE RATINGS MAXIMUM NOCT,up..'m,+m aycer. ,emcerafwe 43 C(t2°Q OperatonafTemperature 40-+850L:. Temperature Coefficient of PMAx 0,34*h/`C Maximum System Voltage 1800VDC(IEQ Temperature Coefficient of Voc -0.25%/°C 1500VDC(UL) Terrperature Coefficient of Ix 0.04%/°C Max Series Fuse Rating 2DA WARRANTY PAC .KAWNC• COINFICUR.".; ION ......... ............ .............................. Cpen CIrcult:Voltage-vscm 38.0 382 ,384 38.6 3as 25 year Product Workmanship Warranty Module, per box;. 36 pieces 25yearPower Warranty modules per40'.c.re ner:828 pieces. P_.. �" .3sr�^�i.�ay," �Vl^", xx r„ 2% First Year Degradation ........ _...... ......_ ............. 0.55/Ann ual P ow or At[enuauo NOCiIrtatllanreateOeW/ma Ambkn(T�rurure 20°CWMs..r-..,:an•z rylea;e refer [op < rr y �cral zl - CAUTION READ SAFETY ANDNSTALLAT!ON INSrf2UCTI0d BEFuRE USING ihE. PRODUCT i 0r h yi' 40�1 n.�a Solar Cc.,Lid. Allrght>reserved Si ecifitatlocs r,ludee,i ,ru C,tashec:zre sub)ecti ha ,qe w,t ou: notice. (.,m,NI Version number iSt4 £EG9D5 N9_EN_2021,_C www.trinasolar.com. IQ8 and IQ8+ Microinverters Commonly used module pairings' w 235 - 3501 235 - 440 Module compatibility 60-cell/120 half -cell 60-cell/120 half -cell and 72-celf/144 half -cell MRPT voltage range v 27-37 29-45 Operating range V 25-48 25-58 Min/max start voltage V 30 / 48 30 / 58 Max input DC voltage V 50 60 Max, DO currene[module [Sol A 15 Overvoitage class DC port it DC port backfeed current '.raA 0 PV array configuration 1xl Ungrounded array; No additional DC side protection required; AC side protection requires max 20A per branch circuit Peak output power VA 245 300 Max continuous output power VA 240 290 Nominal (L L) voltage/range° V -. 240 /.211 - 264 Max continuous output current A 1.0 1.21 Nominal frequency Nz 60 Extended frequency range Hz 50 -68 Max units per 20 A (L L) branch circuit` 16 13 Total harmonic distortion <5% Overvoltago class AC port III AC port backfeed current mA 30 Power factor setting __. 70 Grid -tied power factor (adjustable) 035 leading - 0.85lagging Peak efficiency -,'�, -€ 97.5 -97.6 CEO weighted efficiency / 97 97 Night-time power consumption raw 60 Ambient temperature range,: -4010 to +601C (-40°F to,+140-F) Relative humidity range 4%to 100%(condensing) DG Connector type MC4 Dimensions (HzWxR) 212 mm (8.3") x 175 mm (6.9") x 30.2 mm 0,2") Weight 1.08 kg (2.38 Ibs) Cooling Natural convection - no fans Approved for wet locations Yes Acoustic noise at l m <60dBA Pollution degree': PD3 Enclosure ', Class 11 double -insulated, corrosion resistant polymeric enclosure Envuon. category./ UV exposure rating NEMA Type 6 / outdoor CA Rule 21(UL 1741-SA), QL 62109 1, UL1741/tEEE1547, FCC Part 15 Class&, ICES-0003 Class B, CAN/CSA-C22.2 NO.-107.1-01 Cerftlficaaons This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014, NEC 2017, and NECz202Q section 690.12 and 022.1-2018 Rule 64-218 Rapid Shutdown of PV Systems for AC and DC conductors, when installed according to manufacturer's Instructions. (1) No enforced DC/AC ratio. See the compatibility calculator at https://Iink.enphase.com/ module -compatibility (2) Maximum continuous input DC current is 10.6A (3) Nominal voltage range can be extended beyond nominal if required by the utility. (4) Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. IQ8SP-DS-0002-01-EN-US-2021-10-19 J J a m LU Y w U V J U) r2 Z a-, CD H O Q > O O __J Q ZWorlj mi H m 00 W CD Ln W U = � H n O cV Z CV Z�'�h7 W V) W Z ry� O IC 2 H Z D DWG. NO. S-5 r,t1t111118®p®. Q AGGREGATOR SPECIFICATIONS Q Commercial Aggregator Q-BA-3-3P-35 (three-phase). Combines up to three, single-phase rnicroinvKter branches into a three- phase house run. Proxectwith maximum 40 A, 3-pole QCPD. tt Frier dons )i r f , , r ( _2 in (R)) WE .. =- Homerun conductor size range #12 to 44 AWG tdEltnA'_(ttp to 45' frtirll honzontbrIl, Temperature range -40' C to +55` G (-40' F to +12.2` F) CONDUCTOR SPECIFICATIONS Fiame test rating FT4 C t Kt, combinecfidL'faritl Ursitet) tatek Conducaprtype THHN,-THWN-2 dry/wet Q CABLE TYPES / ORDERING OPTIONS Model Number Max Naminai Voltage Gannector Spacing PY Modu€e Orientation Connector Crsunt per Box. ,m > '� '�.77 UXC = "1.3m�4.2 Q-12-17-240 277 VAC 2.0 m (6,5 ft) € andscape (60-cell) 240 EN'PHASE 0 CABLE ACCESSORIES Name Phodel Numiaer' Dascrlptiern _.__ Field -,vireableconnector (male) Q-CONN-10M Cable Clip Q-CLIP-100 ) Aggregator sealing caps (male) Q-BA-GAP-10 Terminator Q-TERM 10 Replacement DC Adaptor (UTX) Q-DCC-5 Make connections from any Q Aggregator opor, cr nnector Used to fasters cabling to the racking or to ,ecure looped cabling Sealing cap for unused aggregator connections Terminator cap for unused cattle ends DC adaptor to UTX (max voltage 100 VDC) TERMINATOR SEALING CAPS Terminator cap for unused cable Sealing caps for unused aggregator ends, sold in packs often and cable connections (Q-TERM 10) (Q-BA-CAP-10 and Q SEAL:10) DISCONNECT TOOL CABLE CLIP r Plan to use at (east one per Used to fasten cabling to the racking may. installation, sold in packs often or to secure looped cabling, sold in (Q-DISC-10) packs of ten (Q-CLIP-100) To learn more about Enphase offerings, visit enphase.com 2018 Enphase Energy. Ali rights reserver!. All trademarks or bit, nds used are the property of Enphase Energy. Inc. I JY• S P p y p dy : 2018 {i1-03 ,,,,,// IQ Combiner 4C (X-IQ-AMt-240-4C) €Q Combiner 4C with Enphase IQ Gateway printed circuit board for integrated revenue grade PV production metering (ANSI C12.20+,,- 0.5`a) and consumption monitoring (+/-2.5%). Includes Enphase Mobile Connect cellular modem (CELLMODEM-101-06-SP-05), a plug -and -play industrial -grade cell modem for systems up to 60 microinverters- (Avai€able in the US, Canada, Mexico, Puerto Rico, and the US Virgin Islands, where there is adequate cellular service in the installation area) Includes a silver solar shield to match the IQ Battery and IQ System Controller and to deflect heat. ACCESSORIES AND REPLACEMENT PARTS (not included, order separately) w° w ®s w m • N 7479 w )•.• STA : OR N 441 0 Circuit Breakers Supports Eaton SR210, BR215, BR220, BR230, BR240, BR250, and BR260 circuit breakers. BRK-10A-2-240V Circuit breaker, 2 pole,10A, Eaton BR210 BRK-15A 2-240V Circuit breaker, 2 mole, 75A, Eaton BR215 m N z N BRK..2DA-2P-"240V Circuit breaker, 2 pole, 20A, Eaton BR220 BRK-15A-2P-240V-P Circuit breaker, 2 pole, tSA, Eaton BR215B with hold down kit support on\ N¢ - BRK-20A-2R-244V-B Circuit breaker, 2 pole, 20A, Eaton BR220B with hold down kit supportIp Z '�' O yo � IN XA-SOLARSHIEW-ES Replacement solershield for IQ Combiner414C o o XA-ENV-PCBA-3 Replacement IQ Gateway printed circuit board (PCB) for Combiner 414C Z)aA Hold aiowa'x1tfttrEaton ctrcuat r `rt1t� ELECTRICAL SPECIFICATIONS . I'.. f r pp , System voltage 120/240 VAC, 60 H? Max, con. nucce cur rent rating 65 A Max. fuse/lkcuit rating (Output) 90 A Max total branch circuit breaker rating, (ir ;uf` 80A or drstrrhr teo generation / 95A with IQ Gateway breaker included PYrsb t hA � 20.0 A solid core pre ins 1I d k 4 R,10 WIN, vy i Consumption monitoring CT (CT 10C P 1"I"} A pal, 4f 2C0 A s,,l.. care cwremtransformer s MECHANICAL DATA ..r ph is, INeIII hf 7.5 kg (16.5 ibs) Cooling Natural convection, plus heat ahie Id Wim sizes 20 A to 50 A breaker inputs: 14 to 4 AvvG copper conductors • 60 Abreaker branch input: 4 to 1/0 AWG copper conductors Main lug combined output 10 to 2r0 AWG copper conductors Neutral and ground: 14 to n o rp r conductors Always follow local codera ui—ri r N or conductor ctor icing Alzitu.44 TO 2{IOr1 r:�e-er.. 3£it tarn n4allifflo droll Cellular r !rr:JM Mt 06-iP-OS CFLLM M-Mt-06 AT 04 14 based LSE-M1 cellular ular modem), Notrth it at rnphase Mob ierequiredforar Ensernt e installation: EMK u s IR / COMPLIANCE C6ta[5 ...1•`�,.. ��f4a� �" i, 1., .,.-slC.,r,.rarL4r��.li,.�;i/%/l�.✓���e �f.�:K.:.. �,..�... -� Compliance, IQ Gateway UL 606011(CANCSA 22.2 No. 61"0 1 To [earn more about Enphase offerings, visit enphase.com I 2021 Enpi:asa Energy. All rights reserved. Enphase, the Ennhase ogo, Q Comb!her 4/4C, andont r names are trademarks of Enphase energy. Inc. Data subject to ohan e. ":0.21-2021 V _1 to M Z o O M H CIDO co CD OIf) J kb E5 Z l0:::CD rn � __J H m 000 LU CD I LU v = HCD Vl cV z cV Z a M LU Cn v LU Z Z) CD or d Z D F— Z N o Z r- U J U = Z w dam' CD O t-- Z U V U, Li U J n U d Q (n M. NO. S-6 .:aaaaa®arg,d .•¢®A®8s® M? 3 „< Multi Solutions Orr Ao,,,�H /yam „o se t EsI11/�// X Z/J/ PRODUCT: W-DE09,05 13ACKSHEET MONOC Y T 1, LINE MODULE PRODUCT RANGE:380-40ow 400'/W/ 0"u 20a8% MAXIMUM POWER OUTPUT POSITIVE POWER TOLERANCE {MAXIMUM EFFICIENCY °F/' a G h �4 r y � 2 ` Outstanding visual Appearance • Designed with aesthetics in mind • Excellent cell color control by dedicated cell blackening treatment and machine selection. • Thinner wires that appear all black at a distance h," Small in size, twig on }sewer i,..€,.1. p Small form factor. Generate a huge amount of energy even in limited space. • Up to 400W, 20.8°/a module efficiency with high density interconnect technology • Multi-busba r technology for better light trappin g effect, lower series resistance and improved current collection • Reduce installation cost with higher power bin and efficieny • Boost performance in warm weather lower temperature coefficient (-0.34%) and operating temperature Universal .solution for residential and C&I rooftops • ' • Designed for compatibility with existing mainstream optimizers, inverters and mounting systems •• Perfect size and low weight. Easy for handling. Economy fortransporting • Diverse installation solutions. Flexible for system deployment High Reliability • 25 year product warranty • 25 year performance warranty with lowest degradation • Minimized micro -cracks with innovative non-destructive cutting technology • Ensured PID resistance through cell process and module material control • Mechanical performance up to 6000 Pa positive load and 4000 Pa negative load Mounting Systems for scalar technology 1 li 6£sr CrossRail 48-X Technical Data Sheet Nam MECHANICAL PROPERTIES Material: 6000 Series Aluminum Ultimate Tensile Strength: 37.7 ksi (260 MPa) -------- --- Yield Strength: -- -- 34.8 ksi (240 MPa) Weight: 0.56 lbs./ft. (0.833 kg/m) Finish: Mill or Dark Anodized SECTION PROPERTIES Sx: 0.199 in3 (3.261 cm3) SY= 0.153 in3 (2.507 cm3) A (X-Section): 0.467 in2 (3.013 cm2) Genera[ Dimensions: ,�.� ..,. [4216.40j.�,, _,.. 1.54 _ 166 IF 8 1.8 Dimensions in [mm] Inches Notes: s- Structural values and span charts determined in accordance with Aluminum Design Manual and ASCE 7-10 UL2703 Listed System for Fire and Bonding N M U � I m N O N � Z N z o w Z m o o V J J kr) rM Z rn O o �> Q0o J i"j U O CM rz Z00 wo H�t�00 W O LU u7 H Ln VA N z N Za�I`�i W N" LL � o Z D PEN MEN TP 01, Comprehensive Products and System rfarat�` I rs 5 73� r / o/ CrossRail 48-X Technical Data Sheet US1-0817 UL r = e UL t ge ttrt_, er :. j %% �j c ��% (n I : r alt ark ern -f //i G�/ir �,�i „/,�„iI usm- O „- 9534 w u -.m o �.hand Saf. r U w C, o S-9