Single Family Dwelling
Plan Review Comments
1. F.F.E. Shall be a minimum of 8" above the road elevation and a engineered site plan.
2. Lots shall be graded to comply with R401.3 of the F.B.C..
3. Compaction test required if 24" or more of fill dirt is brought in at any one place.
4. Tie in survey required before pouring concrete.
5. Driveways require a R.O.W. use permit.
6. All setbacks shall be met.
7. All property markers shall be uncovered and marked at time of first inspection.
8. All A.D.A. requirements shall be met.
9. No electric, plumbing, mechanical, or framing shall be covered without an inspection and
approval first.
10. All Garages shall comply with section R309.2 of the F.B.C. (Fire Separation).
11. Appliances shall not be installed in a location where subject to mechanical damage unless
protected by approved barriers. M303.4 of the F.B.0
12. Water heaters shall comply with section P607.3 of the .F.B.0
13. Foundation supports for A/C units shall be raised at least 3" above finished grade. M 1308.1
14. Return air in all bedrooms. F.B.C. M1620.4
15. Smoke detectors are to be installed in accordance with R313.1 of the F.B.C.
16. All glazing requirements are to be in accordance with R308.4 of the F.B.C.
17. All means of egress are to be in accordance with R311 of the F.B.C.
18. "Green gypsum board" shall not be used as a backer in showers or tubs. R702.4.2 F.B.C.
19. Combination -type AFCI breakers are required at all locations requiring a AFCI type breaker.
20. Carbon monoxide alarms will be required in new construction that uses fossil -burning heating
or appliances or an attached garage. They shall be installed in accordance with the F.B.C.
21. All plumbing, mechanical, and electrical shall be separate from unit to unit. This includes all
underground plumbing and electric.
22. All 2008 N.E.C. Codes will be enforced.
23. Tamper- Resistant Receptacles in accordance with 406.11 of the 2008 N.E.0
22. In accordance with the Land Development Code, lots shall be sodded before final at least 10
feet around the structure.
F.F.E.-Finished Floor Elevation
F.B.C- Florida Building Code (2010)
R.O.W.-Right Of Way
A.D.A.- Americans with Disabilities Act
N.E.C.- National Electric Code (2008)