HomeMy WebLinkAbout36200 Shady Bluff Lp Lot 3Ln 3n'-O" FLOOR PLAN B 1/4"=>' FOUN. NOT TO SCALE RECESS SLOPENEEDED ♦LLA TION PLAN 114 _1' LINTEL SCHEDULE LINTEL SIZE REINF L1 8 x 16 1- #5 T&B L2 8 x 24 1- #5 T&B L3 8 x 32 1- 5 T&B *PRECAST LINTEL, (1) #5 REBAR IF OVER 6' NO REBAR REQ'D IF LESS THAN 6' L1 K.O. COARSE ALL CELLS, K.O. & P.C. LINTEL FILLED �.• w/3000 PSI CONIC P.C. LINTEL ORS �.- P.C. LINTEL FILLED III PSI CONC off I P.C. LINTEL 'I'm W 2 3 / 4 - jU ..J y 3 TAB FIBERGLASS SHINGLES ON 151 FELT, 1/2' CDX SHEATHING OR 7/16' ROOF PITCH J O.S.B. - 8d RING SHANK NAILS PER ELEVATION J r� o SIMPSON HETA20 A EA PRE—ENGINEERED TRUSS Z END OF EA TRUSS BY OTHERS)Fr W (OR EQUAL) `W -cct* R-30 BAT. INSUL W/ z 2x SUB FASCIA ,/ BAFFELS (SEE ENERGY o o 5 a / CALC.) Z VINYL SOFFIT -• GYP CEILING BRD } r LINTEL BLOCK w/1 15 CONT. T g FILLED w/3000 PSI CONIC. w PRECAST CONIC. LINTEL w/1 — 15 CONT. 0 SPANS Q o LL 6'-0* AND GREATER U L v W l E ac N d U ALUM. WINDOW (SIZE PER PLAN) 1/2' GYP. BRD. 0 WALLS ON 1 x2 PT FURRING STRIPS 0 24' o.c. w/R15 FOAM INJECTED INSUL PRE -CAST CONC. SILL STUCCO FINISH 3 1 /2' CONC. SLAB w/6x6 #10 W.W.M. OR FIBERMESH 15 BAR DOWEL w/10' STD. HOOK (LAP MIN. 25' w/ co VERT. REINF. BAR) FIN. FLR. \ EXISTING UNDISTURBED-• Y-=-: 0 GINEERED S01I Ea N •. -ED TYPICAL CMU WALL SECTION NOT TO SCALE EXISTING UNDISTURBED OR 4' THICK REINF. CONIC. ENGINEERED SOIL . • SLAB W/ 2500 P.S.I. toll I •' I ` ` FIBERMESH 12X18 BELL " i b ?? FOOTER. I (2)-#5 REBAR 12' a- NN w AL T MONO FO 0 TER W DETAIL '—' O H-� � O Q C.0cyD W Q w O � 4' THICK ROW CONC. SLAB W/ 25W P.S.I. FIBERMESH 12XIS BELL 4• THICK REINF. CONC. SLAB FOOTEIL W00 P.S I. FIWWSH 8x8 Q� FOOTER (NO REBAR ROD.; Oo THICKESCALENED EDGE ,r 2}� � � W cn uj 12x 18 FOOTER DETAIL HLTS co G REVIEW ,ATE L^ � S� � U s CITY OF ZEPHY ILLS - r--40 C:o PLANS EXAMINER f cn ALL WORK SHALL COMPLY NTH ALL PREVAILING CODES,FLORIDABUILDING CnDE, NATIONAL ELECTRIC CODE AND CITY Of ZE?Hyp_ TILLS OpDiNANCES f,M G 10/27 fr, PUNS DESIGNED 4 ENCA EERED N ACCORDANCE rd ROMA BULDNG CODE 2014 STH EDITION DRAWN RMH CHECKED CL 10-07-15 SCALE NOTED JOB No. SHEET 1 12 5 11 a IF10 I o■■o■■�o HAND RAIL IIII'lllll IMMI.'� _.. � ..FEE FRONT ELEVATION B 114 " -1 ' REAR ELEVATION 114" _ 1 ' RIGHT ELEVATION 1/4" = 1, 12 5� LEFT ELEVATION 114 " _ > ' 4" STUCCO BAND CORBEL DETAIL 2" CONTINUOUS RIDGE VENT (TYPICAL) FIELD BRACING is not the responsibility of the truss fabricator, truss designer, or plate manufacturer. Persons erecting trusses are cautioned to seek professional advice regarding temporary and erection bracing which is always required to prevent toppling and dominoing during erection, and permanent bracing which may be required in specific applications. Trusses shall be erected and fastened in a straight and plumb position. Vhere no direct top chord sheathing is applied, trusses must be braced at 24' on center maximum, Vhere no direct bottom chord sheathing is applied, trusses must be braced at 10'-0' on center maximum. Trusses must be handled with extreme care during erection to prevent damage or personal injury. Refer to truss engineering for connection and bracing requirements. These calculations are supplied in order for the ENGINEER OF RECORD to adequately provide for connection and integration of the roof assembly to the supporting structure. Designers of supporting connections are SOLELY responsible for the integrity of their product, Trusses remain our property until paid for in full. Truss layouts and engineering may not be reproduced in part or in full under any circumstances. APPROVED TRUSS ANCHOR BY BUILDER 511111017 1 PLUMB CUT OVERHANG HEEL HEIGHT = 2x4 STD. BOTTOM = 2x4 MIN. TOP = 2x4 MIN. -.Md 2.5 12 N TRUSS END DETAIL CONTINUOUS RIDGE VENT (TYPICAL) SPECIAL NOTE ANY PARTY WHO CUTS OR DAMAGES A TRUSS SHALL BE RESPONSIBLE FOR THE ENGINEERING DESIGN AND COST OF THE REQUIRED REPAIR. WARNING !! A SPREADER BAR IS REQUIRED TO PROPERLY SET TRUSSES ON THIS BUILDING. REFER TO HIB 91 SUMMARY SHEET OR CALL (941)665-9001 FOR INFORMATION. TRUSS BRACING 1) THE TOP CHORD PERMANENT BRACING IN THE FORM OF SHEATHING, OR PURLINS FOR A PIGGYBACK CONDITION. 2) BOTTOM CHORD PERMANENT BRACING IN THE FORM OF PURLINS ONLY IN AREAS WHERE THE DRYWALL WILL NEVER BE ATTACHED. THIS CAN OCCUR WHEN A BOTTOM CHORD IS CONCEALED BY A "FILLER" BOTTOM CHORD SECTION OR "FALSE" BOTTOM 3) ALL PERMANENT WEB BRACING AS SPECIFIED BY THE INDIVIDUAL TRUSS DESIGN DRAWING. HMCZ V CWU AL = HUS 26 (SIMPSON) \ = HGUS28-2 (SIMPSON) A k = HGUS28-3 (SIMPSON) STRAP / NAILING SCHD CITY STRAP MFG. NAILING - HUS 26-2 SIMPSON (4) 12d - RT - 18 USP (4) 10d - TA - 20 USP (8) 10d REFER TO ENG PACK FOR CONNECTION — REFER TO ENG PACK FOR CONNECTION CJ5 CJ3 ��h CJ3 o v7 I U in CJ1 v 'CJ1 U 1'-0 4 2' -0" 1'-01 TYPICAL 5' SETBACK CORNERSET LABELING AND SPACING ROOF DETAIL 7) '4 I 2'-0" * 2'-0" 4 TYPICAL 7' SETBACK CORNERSET LABELING AND SPACING /4 " _ 1 ' 12 �5 TRUSS LAYOUT B 1/4" TRUSS ANCHORS TRUSS TO BLK WALL CALCULATED FOR WORST CASE SCENERIO (1) USP TA 20 (OR EQUAL) EACH END EACH TRUSS CONNECTED w/(8) 10d NAILS O EACH STRAP F (1) PLY OR HIP GIRDER, USE (2) USP T O EACH END FOR (2/3) PLY GIRDER USE (2) USP TA20 EACH END FOR GABLE END TRUSS, USE (1) USP TA20 OR EQUAL UNLESS NOTED OTHERWISE ri nnn. �ni.T n /w LI` E� LF GE TC ELECTRIC PLAN 114 1) _ >' TO BUILDING ELECTRICAL NOTES 2" C SMOKE DETECTORS LOCATED ON WALL 12" TO BOTTOM OF BOX OUT. 200 A VANITY LIGHTS 80" TO CENTER OF BOX OUT. FRONT DOOR GFI 4" OFF SLAB CENTER (SEE 10 METER PLAN FOR LOCATION). MCB TV AND PHONE LOCATIONS PER COLOR SHEET. OTHER ELECTRICAL OPTIONS PER COLOR SHEET. DISHWASHER, DISPOSAL OUTLETS UNDER SINK. MICROWAVE PRE -WIRE. 5/8"x10 U/G FROM NOTES GROUND /7- UTILITY CO. 8KW & 3 1/2 TON - 6/2 ROMEX ROD F ELECTRICAL RISER SCALE N.T.S. ELEC LEGEND SYM. DESCRIPTION SINGLE POLE SWITCH THREE WAY SWITCH 4 e FOUR WAY SWITCH 110V RECP. 110V DUPLEX RECP. 220V RECP. 110V GROUND FAULT INTERUPT HALF SWITCHED DUPLEX RECP. LIGHT FIXTURE ® RECESSED LIGHT FIXTURE O JUNCTION BOX EXHAUST FAN ® EXH. FAN/LIGHT COMBINATION ' TELEPHONE JACK / CAT 5 SD SMOKE DETECTOR S�C COMBO SMOKE/CARBON MONOXIDE DET. O TELEVISION OUTLET SPEAKER WIRE OT THERMOSTAT LL LL a Lo J J HVA C PLAN 114 " = 1 ' EQUIPMENT BY (SEE ENERGY CALC) COND SEE ENERGY CALC A/H SEE ENERGY CALC HEATER 8KW) SEER 14 HSPF 7.5 DUCTBOARD R-6.5 FLEX R-6 BOOTS R-6 TAPE FASSON UL 181 a A/C CODE FRAME ROUGH OPENING CODE FRAME ROUGH OPENING 12 18 5 8 X 25 1 2 22 36 1 2 X 25 1 2 13 1858X3778 23 361 2X3778 14 18 5 8 X 50 1 8 24 36 1 2 X 50 1 8 245 36 1 2 X 55 1 2 15 18 5 8 X 62 1 2 25 36 1 2 X 62 1 2 EGRESS 16 1858X71 1 2 26 361 2X71 1/2 EGRESS 17 18 5 8 X 83 1 2 27 36 1 2 X 83 1 2 EGRESS 1 2 32 26 X 25 1 2 32 52 5 8 X 25 1 2 1/2 33 26X3778 33 5258X3778 1/2 34 26X501 8 34 5258X501 8 345 52 5 8 X 55 1 2 1 2 35 26 X 62 1 2 35 52 5 8 X 62 1 2 EGRESS 1/2 36 26X71 78 36 5258X71 1/2 EGRESS 1 2 37 26 X 83 1 8 37 52 5 8 X 83 1 2 EGRESS 2024 24 X 28 3050 36 X 60 2030 24 X 36 3060 36 X 72 EGRESS 2040 24 X 48 3424 40 X 28 2050 24 X 60 3430 40 X 36 2060 24 X 72 3440 40 X 48 2424 28 X 28 3450 40 X 60 2430 28 X 36 3460 40 X 72 EGRESS 2440 28 X 48 3824 44 X 28 2450 28 X 60 3830 44 X 36 2460 28 X 72 3840 44 X 48 2824 32 X 28 3850 44 X 60 2830 32 X 36 3860 44 X 72 EGRESS 2840 32 X 48 4024 48 X 28 2850 32 X 60 4030 48 X 36 2860 32 X 72 4040 48 X 48 3024 36 X 28 4050 48 X 60 3030 36 X 36 4060 48 X 72 EGRESS 3040 36 X 48 GENERAL NOTES SUPPLEMENTAL NOTES A FOUNDATION SURVEY SHALL BE PERFORMED AND A COPY OF THE SURVEY SHALL BE ON THE SITE FOR THE BUILDING INSPECTORS USE. OR, ALL PROPERTY MARKERS SHALL BE EXPOSED AND A STRING STRETCHED FROM MARKER TO MARKER TO VERIFY REQUIRED SETBACKS. ALL PLUMBING, ELECTRICAL AND MECHANICAL ROUGH -INS MUST BE COMPLETE, INSPECTED AND APPROVED BEFORE REQUESTING THE FRAMING INSPECTION. A PERMANENT SIGN WHICH IDENTIFIES THE TERMITE TREATMENT PROVIDER AND NEED FOR RE -INSPECTION AND TREATMENT CONTRACT RENEWAL SHALL BE PROVIDED. THE SIGN SHALL BE POSTED NEAR THE WATER HEATER OR ELECTRIC PANEL. CONDENSATE AND ROOF DOWNSPOUTS SHALL DISCHARGE AT LEAST 1'-0" AWAY FROM BUILDING SIDE WALLS. IRRIGATION/ SPRINKLER SYSTEMS INCLUDING ALL RISERS AND SPRAY HEADS SHALL NOT BE INSTALLED WITHIN 1'-0" OF THE BUILDING SIDE WALLS. TO PROVIDE FOR INSPECTION FOR TERMITE INFESTATION, BETWEEN WALL COVERING AND FINAL EARTH GRADE SHALL NOT BE LESS THAN 6 INCHES. EXCEPTION: PAINT OR DECORATIVE CEMENTITIOUS FINISH LESS THAN 5/8" THICK ADHERED DIRECTLY TO THE FOUNDATION WALL. INITIAL TREATMENT SHALL BE DONE AFTER ALL EXCAVATION AND BACKFILL IS COMPLETE. SOIL DISTURBED AFTER THE INITIAL TREATMENT SHALL BE RETREATED INCLUDING SPACES BOXED OR FORMED. BOXED AREAS IN CONCRETE FLOORS FOR SUBSEQUENT INSTALLATION OF TRAPS, ETC., SHALL BE MADE WITH PERMANENT METAL OR PLASTIC FORMS. PERMANENT FORMS MUST BE OF A SIZE AND DEPTH THAT WILL ELIMINATE THE DISTURBANCE OF SOIL AFTER THE INITIAL TREATMENT. MINIMUM 6 MIL VAPOR RETARDER MUST BE INSTALLED TO PROTECT AGAINST RAINFALL DILUTION. IF RAINFALL OCCURS BEFORE VAPOR RETARDER PLACEMENT, RETREATMENTIS REQUIRED. CONCRETE OVERPOUR AND MORTAR ALONG THE FOUNDATION PERIMETER MUST BE REMOVED BEFORE EXTERIOR SOIL TREATMENT. SOIL TREATMENT MUST BE APPLIED UNDER ALL EXTERIOR CONCRETE OR GRADE WITHIN 1'-0" OF THE STRUCTURE SIDEWALLS. AN EXTERIOR VERTICAL CHEMICAL BARRIER MUST BE INSTALLED AFTER CONSTRUCTION IS COMPLETE INCLUDING LANDSCAPING AND IRRIGATION. ANY SOIL DISTURBED AFTER THE VERTICAL BARRIER IS APPLIED, SHALL BE RETREATED. ALL BUILDINGS ARE REQUIRED TO HAVE PRE -CONSTRUCTION TREATMENT. A CERTIFICATE OF COMPLIANCE MUST BE ISSUED TO THE BUILDING DEPT BY A LICENSED PEST CONTROL COMPANY BEFORE A CERTIFICATE OF OCCUPANCY WILL BE ISSUED. THE CERTIFICATE OF COMPLIANCE SHALL STATE: "THE BUILDING HAS RECEIVED A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN TERMITES. THE TREATMENT IS IN ACCORDANCE WITH THE RULES & LAWS OF THE FLORIDA DEPT OF AGRICULTURE AND CONSUMER SERVICES." AFTER ALL WORK IS COMPLETED, LOOSE WOOD AND FILL MUST BE REMOVED FROM BELOW AND WITHIN 1'-0" OF THE BUILDING. THIS INCLUDES ALL GRADE STAKES, TUB TRAP BOXES, FORMS, SHORING OR OTHER CELLULOSE CONTAINING MATERIAL. NO WOOD, VEGETATION, STUMPS, CARDBOARD, TRASH, ETC., SHALL BE BURIED WITHIN 15'-0" OF ANY BUILDING OR PROPOSED BUILDING. MASONRY GENERAL NOTES STRUCTURAL DESIGN CRITERIA 1. MASONRY CONSTRUCTION SHALL CONFORM TO ACI STANDARD BUILDING CODE 1. FBC / FBCR 2014 REQUIRMENTS FOR CONCRETE MASONRY STRUCTURES (ACI 530-11). 2. ASCE/SEI 7-10 CODE (140 mph) 2. CONCRETE BLKS SHALL CONFORM TO ASTM C 90 (28 DAY STRENGTH=2000 3. STRUCTURE RISK CATEGGORY = II PSI, FM=1350 PSI) LAID IN RUNNING BOND. 4. ENVELOPE PROCEDURE FOR LOW RISE BUILDINGS 3. MORTAR SHALL BE TYPE S OR M. 5. EXPOSURE FACTOR = B 4. WHERE SHOWN, CELLS OF MASONRY BLOCK SHALL BE FILLED WITH CONCRETE 6. INTERNAL PRESSURE COEFFICENT = f0.18 WITH A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI AT 28 DAYS & 1-#5. 7. 2nd FL LOADS: UVE LOAD-40 PSF/DEAD LOAD-10 PSF VERTICAL. 8. ROOF LOADS: LIVE LOAD-20 PSF/DEAD LOAD-10 PSF 5. PROVIDE KNOCK -OUT IN CONCRETE MASONRY UNIT AT BASE OF EACH FILLED 9. COMPONENT & CLADDING WALL PRESSURE= (+35.3) (-47.2) PSF (MAX) CELL TO ALLOW VISUAL VERIFICATION OF COMPLETE GROUT PENETRATION. ROOFING / FLASHING DRAINAGE ROOF DEAD LOAD - 7# P.S.F. ROOF LIVE LOAD - 20# P.S.F. ALL ROOF PROVIDE AN ALTERNATE METHOD OF DIVERTING WATER AWAY FROM THE COMPONENTS ARE PRE-ENGINEERED TRUSSES. ENG. WILL BE SUPPLIED TO FOUNDATION, WHICH WAS NEEDED IN SITUATIONS LIKE "ZERO-LOT-UNE" FIELD INSPECTOR AT TIME OF FRAMING INSPECTION (SEE TRUSS LAYOUT CIRCUMSTANCES. THE ALTERNATIVE IS TO PROVIDE A MINIMUM OF 5% PROVIDED.) ROOF SHEATHING NAILING SCHEDULE FOR 7/16" OSB ROOF SLOPE AWAY FROM THE FOUNDATION. DECK, USE 8d RING SHANK NAILS, SPACE 6" O.C. AT EDGES & 6' O.C. STEMWALL FOOTING IN FIELDS. GAF SENTINEL/TIMBERLINE/CERTAINTEED FIBERGLASS SHINGLES STEMWALL FOOTING AS SHOWN ON WALL SECTION UP TO 36" HIGH CAN BE SECURE wA5) NAILS PER SHINGLE ON UNDERLAYMENT OVER 7/16' OSB USED WITH UNBALANCED FILL. UNBALANCED FILL GREATER THAN 36' SHALL BE ROOF DECK. PRODUCT MEETS ASTM D3462, D3161 F, D7158 G AND UL TEMPORARILY SUPPORTED DURING BACKFIWNG & CONCRETE SLAB PLACEMENT 997 FOR NAND SPEEDS UP TO 140 MPH. FLASH ALL VALLEYS W/ MIN. BY CONTRACTOR. THE MAXIMUM STEMWALL HEIGHT SHALL BE 10'-0" 16"x26GA VALLEY METAL PLACED OVER UNDERLAYMENT NAILED 12" o.c. WINDOWS 0 EDGES. WHERE WALLS MEET ROOF LINE, ALL FLASHING SHALL CONFORM ALL WINDOWS TESTED AND APPROVED IN ACCORDANCE WITH ANSI/AMMA/NWWDA TO FBC REQUIREMENTS. UNDERLAYMENTS SHALL CONFORM WITH ASTM 101/IS2 STANDARD AND LABELED AS SUCH. WINDOWS TO BE INSTALLED PER D226, ASTM D4869, OR ASTM D6757. INSTALLED PER R905.2.7 AND MANUFACTURERS REQUIREMENTS FOR APPLICABLE DESIGN PRESSURE. WINDOWS MANUFACTURER'S SPECS. IN MASONRY WALLS SHALL BE ANCHORED THROUGH 1x BUCK INTO MASONRY. FRAMED WALLS WINDOWS IN WOOD FRAMED WALLS MAY BE INSTALLED WITHOUT BUCKS. ALL ALL INTERIOR NON -BEARING WALLS MEET R6021.3.1. LUMBER TO BE MULLIONS SHALL CONFORM TO FBC REQUIREMENTS OF 1.5x THE DESIGN LOAD. STD SPF OR HIGHER GRADE. THE LOWEST PART OF THE CLEAR OPENING OF THE WINDOW TO BE A MIN. OF ALL INTERIOR FRAMED BEARING WALLS TO BE #2 SPF. 24" ABOVE FINISHED FLOOR WHERE THE OPENING OF THE OPERABLE WINDOW ALL WOOD BEARING HEADERS TO BE #2 SYP (SIZES AS INDICATED ON PLAN) IS LOCATED MORE THAN 72' ABOVE FINISHED GRADE OR THE SURFACE BELOW. FRAMED GARAGE WALLS TO HAVE MIN 1/2" GYPSUM BRD (IF AREA ABOVE EXCEPT FOR WINDOWS WHOSE OPENINGS WONT ALLOW A 4" DIA. SPHERE TO GARAGE IS HABITABLE, USE 5 8 TYPE X GYPSUM BRD ON CLING PASS AND OPENINGS THAT ARE PROVIDED WITH GUARDS COMPLY WITH ASTM F / " )• 2006 OR ASTM F 2090. TRUSS ANCHORS GARAGE DOOR TRUSS TO BLK WALL CALCULATED FOR WORST CASE SCENERIO (1) SIMPSON GARAGE DOOR TO BE 140 MPH RATED (MIN +18.3/-20.4 PSF DWP) INSTALL HETA20 (OR EQUAL) EACH END EACH TRUSS CONNECTED wA9) 10d NAILS 2x6 PT EA SIDE w/(3) 1/2"x8" "J" BOLTS w/2" WASHERS SPACED EQUALLY EACH STRAP FOR (1) PLY OR HIP GIRDER. USE (2) SIMPSON HHETA20 EACH END ALONG LEGNTH EMBEDED INTO POURED CELLS (OPTION: MAY USE 1/2"x6' FOR (2/3) PLY GIRDER. USE (2) SIMPSON HHETA20 EACH END FOR GABLE END WEDGE ANCHORS W/2" WASHERS) ANCHOR 2x6 PT ABOVE DOOR TO LINTEL W/ TRUSS, USE (1) SIMPSON HETA20 OR EQUAL UNLESS NOTED OTHERWISE WEDGE ANCHORS, CONCRETE SCREWS OR .145"0 P.D.F.'s A PERMANENT LABEL MISPLACED TRUSS STRAP IN THE GAS WHERE TRUSS STRAP IS MISSING THE IS REQUIRED AND THE INSTALLAT10N INSTRUCTIONS ARE REQUIRED TO BE PROVIDED AND AVAILABLE ON THE JOB SITE AS WELL. THIS ADDITION ENABLES FOLLOWING MLTHOD MAY BE USLD AS AN ALTERNATE. SUBSTITUTE A SIMPSON ENABLES ASSURANCE OF COMPLIANCE MTS18 OR HUGHES RT18 TW (OR EQUIVALENT) FOR EACH HETA20-18 MISSED. EXTERIOR PRE -HUNG DOORS CONNECT TRAP TO BOND BEAM WITH (3) 3/16" X 1 3/4" HEX HEAD TAPCONS. 1x DOOR BUCK (IF REQD) TO BE ATTACHED TO MASONRY WALL w/1 1/2 006 THIS SUBSTITUTION IS GOOD FOR A MAXIMUM UPLIFT OF 1,000# PER STRAP. WIRE COLLATED NAILS 0 4"O.C. 2x DOOR BUCK (IF REQD) TO BE ATTACHED TO ELECTRICAL NOTES MASONRY WALL w/2 1/2x.106 WIRE COLLATED NAILS 0 4" O.C. SECURE PRE- ELECTRICAL SYSTEMS AS INDICATED ON THESE PLANS ARE SCHEMATIC ONLY HUNG DOOR UNIT PRE MFG SPECS. AND DESIGNS SHALL BE PREPARED IN ACCORDANCE WITH THE NATIONAL ELECTRIC CODE (2011 NEC). ATTIC ACCESS SMOKE DET. LOCATED ON WALL 12 TO BOT. OF BOX OUT. VANITY LIGHTS ATTIC ACCESS SHALL COMPLY WITH SECTION R807.1 WITH A MIN. OPENING OF 80" TO CENTER OF BOX OUT. FRONT DOOR GFI 4" OFF SLAB CENTER (SEE 22"00". PLAN FOR LOC.) TV & PHONE LOCATIONS PER COLOR SHEET. OTHER ELECTRICAL OPTIONS PER COLOR SHEET. DISHWASHER, DISPOSAL OUTLETS EXTERIOR SIDING UNDER SINK. MICROWAVE PRE -WIRE. 1OKW & 5 TON - 6/2 ROMEX. FRONT 16" OSB SHEATHING NAIL w 8d CC 6" O.C. DOOR GFI 4" OFF SLAB CENTER (SEE PLAN FOR LOCATION) MIN 3/8" LP SMARTPANEL OR 7 / / ALL ELECTRICAL AT SLIDING GLASS DOOR TO BE ON RIGHT HAND SIDE EDGES & 6" O.C. IN FIELDS REGUARDLESS OF GARAGE HANDING. MISPLACED WALL RIENFORCING NOTE USE OF AFCI RECEPTACLES AND TAMPER RESISTANT RECEPTACLES IN THE CASE WHERE A FOOTING DOWEL IS MISPLACED THE FOLLOWING LATH CORRECTION IS ACCEPTABLE: ADD A DOWNPOUR w/(1) #5 VERT REINFORCING ALL ATTACHMENTS FOR SECURING WIRE LATH SHALL BE SPACED NOT IN THE CORRECT ORIGINAL LOCATION. THE BAR SHALL BE TIED INTO THE BOND MORE THAN 6' APART, AND SIDE LAPS SHALL BE SECURED TO SUPPORTS BEAM w/ A MIN. HOOK OF 10 IF THE NEW DOWEL LOCATION IS MORE THAN 8" AND BE TIED BETWEEN SUPPORTS NOT TO EXCEED 9". ALL METAL LATH OFFSET FROM ORIGINAL LOCATION THE BOTTOM OF THE BAR SHALL HAVE A SHALL BE LAPPED 1 MIN. METAL WIRE LATH SHALL BE ATTACHED TO #5x24" LONG DOWEL DRILLED 4" INTO THE CONCRETE SLAB & SET IN SIMPSON VERTICAL ER ICAL W PENETRATION IT 3TH; AND BENT OF 4d GALVANIZED SET EPDXY. 5 LESS THAN 8" NO EPDXY NEEDED. CELL SHALL BE FILLED STRANDS OF LATH. A BOND BREAK SHALL BE PROVIDED BETWEEN THE w/ A MIN. 2500 PSI CONCRETE. WATER- RESISTIVE BARRIER & THE CEMENT PLASTER CONSISTING OF ONE FLASHING, SEALANTS, AND WEATHERSTRIPPING OF THE FOLLOWING: TWO LAYERS OF AN APPRVD WATER-RESISTANT BARRIER MATERIAL OR ONE LAYER OF AND APPVD WATER-RESISTANT ALL FENESTRATIONS PRODUCTS TO BE SEALED AT THE JUNCTURE OF THE BARRIER OVER AN APPRVD PLASTIC HOUSE WRAP SHALL BE UNDER BUILDING WALL WITH A SEALANT COMPLYING WITH AAMA 800 AND ASTM C WIRE LATH. 920, ASTM C 1281, AA812, OR OTHER APPROVED STANDARD. FENESTRATION LOAD -BEARING PRESSURE CLASS OF MATERIAL (LBS. PER SQ/FT) CRYSTALLINE BEDROCK 12,000 SEDIMENTARY AND FOLIATED ROCK 4,000 SANDY GRAVEL AND/OR GRAVEL 3,000 (GW AND GP) SAND, SILTY SAND, CLAYEY SAND, 2,000 SILTY GRAVEL AND CLAYEY GRAVEL (SW,SP,SM,SC,GM AND GC) CLAY, SANDY CLAY, SILTY CLAY, 1,500 CLAYEY SILT, SILT AND SANDY SILT (CL,ML,MH AND CH) JUNCTURE OF EXTERIOR PLASTER AND ANY FENESTRATION PRODUCT IS REQD TO BE SEALED WITH A SEALANT COMPLYING WITH SECTION 612.12 PLUMBING ON MONO SLABS THE SEWER AND HVAC CONDENSATE LINE WILL GO UNDER THE FOOTER, ON A STEM WALL THE LINES WILL GO THROUGH THE BLOCK FOR THE LINE THAT PASSES THROUGH IT WILL BE SLEEVED WITH A PIPE TWICE THE SIZE OF IT 3" WILL BE SLEEVED WITH 6" AND 3/4" WILL BE SLEEVED WITH 1 1/2'. RECIRCULATION OF AIR M1507.2 EXHAUSET AIR FROM BATHROOMS AND TOILET ROOMS SHALL NOT BE RECIRCULATED WITHIN A RESIDENCE OR TO ANOTHER DWELLING UNIT AND SHALL BE EXHAUSTED DIRECTLY TO THE OUTDOORS. APPLIANCE PROTECTION M1307.3.1 ALL APPLIANCES SHALL BE PROTECTED FROM IMPACT BY AN APPROVED BARRIER SINGLE DOOR FL# CODE VERSION STATUS MANUFACTURER CATEGORY SUB CATEGORY PRODUCT MODEL # OR NAME PRODUCT DESCRIPTION BOORS RESISTANT GLAZING 15585.1 2014 APPRVD CROFT LLC WINDOWS SINGLE HUNG 96 SERIES SINGLE HUNG ALUMINUM SH WINDOW 16079.1 2014 APPRVD CROFT LLC EXTERIOR DOORS SLIDING EXT DOOR ASSEMBLIES 3000 SERIES SLIDING GLASS DOOR 17680.2 2014 APPRVD UNITED STEEL PRODUCTS COMPANY STRUCTURAL COMPONENTS WOOD CONNECTOR ANCHORS 10655-R3 2014 APPRVD SIMPSON STONG-TIE COMPANY STRUCTURAL COMPONENTS WOOD CONNECTOR ANCHORS 1774-R4 2014 APPRVD COMMERCIAL CONIC COMPANY STRUCTURAL COMPONENTS PRECAST/PRE- STRESSED LINTELS 8' &12' LINTELS 4904-R7 2014 APPRVD MASONITE INTERNATIONAL EXTERIOR DOORS SWINGING EXT DOOR ASSEMBLIES STEEL DOOR WITH OR WITHOUT SIDELITES 444.1 2014 APPRVD CERTAINTEED CORPORATION ROOFING ASPHALT SHINGLES 3-TAB / ARCH LAMINATED SHINGLE 075-R7 2014 APPRVD FL METAL PRODUCT COMPANY INC ROOFING ROOFING ACCESSORIES RIDGE VENT 5219.1-R2 2014 APPRVD TAMCO ROOFING ROOFING ACCESSORIES OFF RIDGE VENT 15279.20 2014 APPRVD CLOPAY BLDG PRODUCTS CO EXTERIOR DOORS SECTIONAL EXT DOOR ASSEMBLIES WINDCODE W4 GARAGE DOOR 13389.1 2014 APPRVD CERTAINTEED CORPORATION PANEL WALLS SOFFITS VINYL SOFFITS !APPRVDrct 13192 2014 ul In9 . PANEL WALLS SIDING LAP SIDING 9190-R6 2014 APPRVDroducts PANEL WALLS SIDING SMART PANEL ENG. WOOD EXT PANEL 17194.1 2014 APPRVD ROBETEX INC ROOFING UNDERLAYMENT TECH WRAP SYN. UNDERLAYMENT DOUBLE DOOR SINGLE DOOR W/ SDLT SINGLE DOOR WA2) SDLTS EXTERIOR PRE -HUNG DOORS SECURE PRE -HUNG DOOR UNIT USE 10 WOOD SCREWS/TAPCONS USE SIMPSON 1/4" X 1 1/2" MIN NAILON PINS AT THRESHOLD DOOR INSTALATIONIFASTENER PLACEMENT NOT SCALE ROOF PITCH PER ELEVATION �- CONNECT BEAM TO TRUSS W/SIMPSON MTS12. U.N.O. I 2 SYP BEAM SIZE PER PLAN) STRAP A1) SIMPSON HETA20 ALL CELLS THAT FLOOR PLAN INDICATES REBAR SHALL BE CONCRETE FILLED. CMU COLUMN AT FRONT ENTRY VER71CALPARCHCOLWUA"5 HEIGHT PER ELEVATION) (COLUMN SIZE & REBAR PLACEMENT PER FLOOR PLAN) FOOTING DOWELS: 2-#5 EMBED. 6" MIN. I Ldi/-INTO FTG. W/ 90' HOOK PAD PER FOUND PLAN MASONRY COLUMN DETAIL W/UPSET BEAM (ENTRY) NOT M SCALE ROOF PITCH PER ELEVATION TRUSS STRAP PER GENERAL NOTES /() # ( &B) CONTI UOUS S1PAN5 BETWEEN COLUMNS W/MIN. 8" BEARING SURFACE EACH END CAP ALL CELLS THAT FLOOR PLAN INDICATES REBAR SHALL BE CONCRETE FILLED. ' \-CMU COLUMN AT FRONT ENTRY PORCH W/�Y5 VERTICAL (COLU HEIGHT PER ELEVATION) (COLUMN SIZE & REBAR PLACEMENT PER FLOOR PLAN) I FOOTING DOWELS: 2-#5 EMBED. 6' MIN. INTO FTG. W/ 90' HOOK PAD PER FOUND PLAN MASONRY COLUMN DETAIL W/PRECAST LINTEL NOT M SCALE 26 GA VALLEY METAL (SEE GENERAL NOTES FOR NAIL PATTERN) ROOF DECK W/15/ FELT NOTES TYPICAL EACH SIDE VALLEY FLASHING DETAIL NOT M SCALE SIDING METAL FLASHING SHINGLE ROOF CEMENT ROOF DECK FLASHING DETAIL ROOF VENTILATION CALCULATIONS FLORIDA BUILDING CODE 2014 SECTION 806.2 - 1 /300 TOTAL ATTIC SPACE-2220.00 NET FREE VENT NEEDED - 532.80 # OF RIDGE VENTS - 3.00 # OF OFF RIDGE VENTS - NA COMPONENTS FLORIDA SECTION AND CLADDING BUILDING CODE 2014 301.2 140 MPH NO. ZONE EFFECTIVE WIND AREA DESIGN WIND PRESSURE A 4 10 +35.3/-38.2 B 4 20 +33.7/-36.7 C 4 50 +31.6/-34.6 D 4 100 +30.0/-33.0 AA 5 10 +35,3/-47,2 BB 5 20 +33.7/-44.0 CC 5 50 +31.6/-39.8 DD 5 100 +30.0/-36.7 TYPICAL EXAMPLES A 1 /2 32, 1 /2 33, 1 /2 34, 22 B 1 /2 SH 35, 1 /2 36, ALL SH 32-34, 3-0 DOOR OR 2- LESS C SH 35, 36, 5-0 OR 6-0 SGD 8-0 SGD, 8-0 CHID 16-0 X 7-0 OHD < +22.0/-26.9 CODE *ACTUAL* FLANGE W94M SIZE OFFING PLIGHT OPEINdG) 12 191 8X26 20X2618 13 1918X384 20X3812 14 191 8X5058 20X5034 15 19 t 8X63 20X631 8 16 191 8X72 20X7218 17 191 8X84 20X841 8 1 232 261 8X26 2738X261 8 26 t 8X3838 2738X381 2 261 8X5058 2738X5034 261 8X63 2738X6318 t236 261 8X72 2738X721 8 2618X84 2738X841 836X26 2738X261 8 23 36X3838 3778X381 2 24 1 36X5058 3778X5034 zu7 26 37 X 7 X 72 148 27 37 X 84 EGRESS 37 718 X 84 1 8 485 48 X 63 EGRESS 49 X 63 1 8 32 53 1 8 X 26 54 X 26 1 8 33 53 1 8 X 38 3 8 54 X 38 1 2 34 531 8X5058 54X5034 345 53 1 8 X 50 1/4 54 X 56 3 8 35 53 1 8 X 63 EGRESS 54 X 63 1 8 36 53 1 8 X 72 EGRESS 54 x 72 1 8 37 53 1 8 X 84 EGRESS 54 x 84 1 8 NOTE MJ<LNG C RS TOMM" U 1 DM RM OPG S12E NO AW (1O ) ACNZE AL MM SIFOR EACH TAOO1r. COOS SUDING GLASS DOORS BLOCK OPENING SIZE (I FRAME OPENING 1/4 X N 1/4 st 4 ■ In . s■a X N 1/4 X N 1/4 n 4. 81 .Fa xN 1/4X01/4 27 4■61 N 7/8 x N 1/4 1a : n 1»�xN 1»7AX 01/4 121 V11 xV xv 1425"AxN 11427/81 N1/4 144 3A.M 143 5A X N 1143 7A X N 1/4 145 : $I 1!1 3/r x N 1103 7A X 1/4 10 V11 a M CONVENTIONAL VALLEY FRAMING DETAIL GABLE END. COMMON RIDGE BEAM TRUSS OR GIRDER TRUSS 7 (SEE NOTE 16) VALLEY RAFTERS (24' O.C. MAX) 12 P TRUSS TYPICAL (24- O.C.) POST SEE NOTE �8) (DNISTRUCTION SEQUENCE (ALL MATERIAL 32 OR BETTER) TRUSS MUST -' BE SHEATHED 1. INSTALL BASE TRUSSES. 2. APPLY SHEATHING TO TOP CHORD OF SUPPORTING TRUSSES IF SHEATHING IS NOT APPLIED. PROVIDE 2x4 PURUNS AT 24' O.C. ON THE TOP CHORD OF THE SUPPORTING TRUSSES UNDER THE VALLEY FRAMING. CONNECT PURLINS TO EACH TRUSS WITH (2) - 16d NAILS. 3. BRACE BOTTOM CHORD AND WEB MEMBERS PER TRUSS DESIGNS. 4. INSTALL 2 x 4 VALLEY PLATES. FASTEN TO EACH SUPPORTING TRUSS WITH (2) 16d NAILS. 5. DEFINE VALLEY RIDGE BY RUNNING A LEVEL STRING FROM THE NTERSECTNG RIDGE OF THE (a.) GABLE END. (b.) GIRDER TRUSS OR (c.) COMMON TRUSS TO ROOF SHEATHING. 6. SET 2 x 6 /2 RIDGE BEAM. SUPPORT WITH 2 x 4 POSTS SPACED 48' O.C. BEVEL BOTTOM OF POST TO SET EVENLY ON THE SHEATHING. FASTEN POST TO ROOF SHEATHING WITH (3) 10d TOE NAILS. 7. FRAME VALLEY WIRERS FROM VALLEY PLATE TO RIDGE BEAM. MAXIMUM RAFTER SPACING IS 24" O.C. FASTEN VALLEY WAFTER TO RIDGE BEAM WITH (3) 16d NAILS. FASTEN VALLEY WAFTER TO VALLEY PLATE WITH (3) 16d TOE NAILS. S. SUPPORT THE VALLEY RAFTERS WITH 2 x 4 POSTS 48' O.C. (OR LESS) ALONG EACH WAFTER. INSTALL POSTS IN A STAGGERED PATTERN AS SHOWN ON PLAN DRAWING ALLIGN POSTS WITH TRUSSES BELOW. FASTEN VALLEY RAFTER TO POST WITH (4) 10d NAILS. FASTEN POST TO SHEATHING WITH (3) 16d TOE NAILS. FOR PURUN APPLICATION. CONNECT 2x4 POST TO FACE OF TOP CHORD WITH (4) 100 NAILS. 2x4 RAT RUNS OR 2X4 BLOCKING 4'-0" O.C. FOR FIRST FOUR---7 FRAMING SPACES FROM EACH END STRAP TRUSS w/ 2-16d SN1NP901N HETA20 (OR EQUAL) USING (6) 10d NAILS (MIN) 6 48' O.C. 1 2X6 PLATE CONTINUOUS 14' LENGTHS MINIMUMA CONNECTED TO CMU WALL W/1/2' X 8' ANCHOR BOLT 2-16d O 32' O.C. BOND BEAM L- 5d COOLER NAILS OR GWB54 O r O.C. GABLE END TRUSS CONNECTION STWICIU ALLY CONTINIXM WAIL NOT M SCAM VALLEY PLATE (SEE NOTE /4) POST NOTE WE GABLE END. COMMON TRUSS OR GNDER TRUSS LINE LOAD = 30 PSF (MAX) DEAD LOAD = 15 PSIF (MAX) D.O.L.. INC. 1.15 ASCE 7-10 (MWFRS) 140 MPH NOTE 48' O.C. MAXIMUM POST SPACING �l 0