5915 Gall Blvd (3)
GENERAL NOTES 1. THESE DWGS ARE THE PROPERTY OF GLOBAL CONSULTING ENGINEERS, INC. AND SHALL NOT BE USED, REPRODUCED, OR ALTERED IN ANY WAY WITHOUT THE PRIOR EXPRESSED WRITTEN CONSENT. ANY CHANGES, DELETIONS OR ADDITIONS TO THESE DRAWINGS WITHOUT CONSENT IS STRICTLY PROHIBITED. 2. ANY AND ALL ITEMS REQUIRED TO FURNISH A COMPLETE CONSTRUCTION, BUT NOT SPECIFICALLY SHOWN OR SPECIFIED ON THE DRAWINGS SHALL BE FURNISHED AND INSTALLED IN CONFORMANCE TO THE FLORIDA BUILDING CODE AND LOCAL ORDINANCES AND IN GOOD WORKMANLIKE MANNER. 3. IT IS NOT THE INTENT OF THESE DRAWINGS TO SHOW EVERY DETAIL OF CONSTRUCTION. THE CONTRACTOR IS EXPECTED TO FURNISH AND INSTALL ALL ITEMS REQUIRED TO COMPLETE THE WORK. 4. THE ENGINEER IS NOT RESPONSIBLE FOR THE EXISTING BUILDING, BUILDING UTILITIES OR WORK NOT SPECIFICALLY SHOWN OR SPECIFIED ON THESE DRAWINGS. 5. THE CONTRACTOR SHALL PROVIDE ALL REQUIRED BUILDING PERMITS, INSURANCES, LICENSES, TAXES, ETC. REQUIRED TO PERFORM THE WORK OUTLINED IN THE DRAWINGS. 6. THE CONTRACTOR SHALL COORDINATE AND SUPERVISE ALL THE WORK PERFORMED BY HIS FORCES AND BY SUBCONTRACTORS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION AND VERIFICATION WITH OTHER TRADES TO ASSURE COMPLIANCE WITH THE APPROVED DRAWINGS. 7. THE CONTRACTOR SHALL VERIFY SIZES AND LOCATIONS OF ALL MECHANICAL, PLUMBING AND ELECTRICAL EQUIPMENT PRIOR TO COMMENCING THE WORK. 8. THE CONTRACTOR SHALL COORDINATE ALL PARKING, STORAGE, TRASH REMOVAL, ETC. WITH THE OWNER OR BUILDING MANAGER. 9. ABBREVIATIONS NOTED IN THE DRAWINGS OR SPECIFICATIONS ARE THOSE COMMONLY USED. THE ENGINEER WILL DEFINE ANY ABBREVIATION QUESTIONED UPON REQUEST. 10. THE CONTRACTOR SHALL PROVIDE ALL NECESSARY TEMPORARY BARRIERS, LIGHTING, COVERING, BRACING, SHORING, FIRE PREVENTION AND OTHER EQUIPMENT NECESSARY TO PROTECT THE SAFETY AND SECURITY OF ALL PERSONS AND THE PROPERTY THROUGHOUT THE ENTIRE PERIOD OF CONSTRUCTION. 11. THE CONTRACTOR SHALL REPAIR OR REPLACE ANY EXISTING FINISHES AND/OR ANY ITEMS DAMAGED DURING CONSTRUCTION TO MATCH THE ADJACENT EXISTING. 12. THE PLANS ARE NOT TO BE SCALED. THE PLANS AND DIAGRAMS SHOW RELATIVE LOCATIONS AND ACTUAL EXISTING LOCATIONS MAY VARY IN THE FIELD. 13. THE CONTRACTOR SHALL REVIEW EXISTING BUILDING SYSTEMS AND UTILITIES AS TO THEIR COMPLIANCE WITH THE FLORIDA BUILDING CODE AND OTHER APPLICABLE CODES AND NOTIFY THE ENGINEER OF ANY NON -CONFORMING ITEMS FOUND. 14. SECTIONS AND DETAILS SHOWN TYPICAL ON THE PLANS MAY NOT BE SPECIFICALLY NOTED AT EACH APPLICABLE LOCATION. HOWEVER, THESE DETAILS MAY BE APPLICABLE OR MAY BE REQUIRED IN MORE THAN ONE LOCATION. 15. THE CONTRACTOR SHALL COORDINATE HIS CONSTRUCTION SCHEDULES, PLANNED POWER OUTGOS, NIGHTTIME WORK, WEEKEND WORK AND WORK IN OTHER ADJACENT TENANT SPACES WITH THE OWNER PRIOR TO PERFORMING THE WORK. 16. THE CONTRACTOR SHALL SUPPLY THE OWNER WITH ALL EQUIPMENT MANUALS AND WARRANTIES. 17. THE CONTRACTOR SHALL GUARANTEE IN WRITING ALL MATERIALS AND LABOR FOR A PERIOD OF ONE YEAR FROM THE DATE OF FINAL ACCEPTANCE BY THE OWNER AND WILL AT HIS OWN COST REPAIR OR REPLACE ALL WORK OR DAMAGES CAUSED BY THE WORK WHICH BECOMES DEFECTIVE DURING THE TERM OF THE GUARANTEE. AND OTHER SPECIFIC REQUIREMENTS MAY BE MODIFIED OR EXTENDED BY THE OWNER/CONTRACTOR AGREEMENT. 18. WHERE DISSIMILAR METALS COME IN CONTACT, THE CONTRACTOR SHALL PROVIDE PROPER INSULATION TO PREVENT GALVANIC OR ELECTROLYTIC ACTION AS WELL AS VIBRATION OR NOISE TRANSMISSION. 19. THE CONTRACTOR SHALL PROVIDE THE OWNER WITH A SET OF AS BUILT DRAWINGS INDICATING ALL FILED CHANGES, ADDITIONS OR DELETIONS MADE DURING CONSTRUCTION. 20. ALL DEMOLITION SHALL BE COORDINATED WITH THE OWNER PRIOR TO PERFORMING THE WORK. 21. ALL NEW MATERIALS/EQUIPMENT SHALL HAVE U.L. (UNDERWRITER'S LABORATORY) APPROVED LABELS AS ACCEPTED BY LOCAL AUTHORITY. 22. ELECTRICAL CONTRACTOR SHALL COORDINATE ALL HIS WORK WITH THE UTILITY COMPANIES TO ASSURE THAT IT COMPLIES WITH THEIR REQUIREMENTS. 23. ALL WORK PERFORMED UNDER THIS CONTRACT SHALL COMPLY WITH ALL NATIONAL, STATE, AND LOCAL CODES HAVING JURISDICTION AND WITH ALL REQUIREMENTS OF THE UTILITY COMPANIES WHOSE SERVICES SHALL BE USED. 24. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS AND SHALL NOTIFY THE ARCHITECT IF ANY DISCREPANCIES ARE DISCOVERED OR DEVIATIONS FROM THE APPROVED PLANS REQUIRED BEFORE PROCEEDING WITH THE WORK INVOLVED. COMMENCEMENT OF THE WORK SHALL CONSTITUTE ACCEPTANCE OF EXISTING CONDITIONS. 25. IF DOUBT EXISTS IN THE MIND OF THE BIDDER AS TO THE TRUE MEANING OF ANY PART OF THESE CONSTRUCTION DRAWINGS, BIDDER MUST REQUEST THE INFORMATION IN WRITING FROM THE ENGINEER IMMEDIATELY. 26. ALL SHOP DRAWINGS SHALL BE SUBMITTED W/ CONTRACTOR'S REVIEW STAMP TO ENGINEER FOR APPROVAL PRIOR TO FABRICATION. ALLOW 10 BUSINESS DAYS FOR REVIEW. 27. ANY SUBSTITUTIONS MUST BE REVIEWED AND APPROVED IN WRITTING BY THE ENGINEER PRIOR TO FABRICATION OR PURCHASING. 28. ALL WOOD IN CONTACT WITH MASONRY SHALL BE PRESSURE TREATED 29. ALL MATERIALS SHALL HAVE A MINIMUM CLASS "C" FLAME SPREAD RATING. 30. PROVIDE ONE TYPE ABC RATED FIRE EXTINGUISHER PER EVERY 3000 S.F. OR FRACTION THEREOF OF BUILDING AREA. (PROVIDE 2 MIN.) 31. ALL NEW WALLS SHALL RECEIVE ONE COAT OF PRIMER PRIOR TO RECEIVING TWO COATS OF INTERIOR LATEX PAINT. COLOR AS SELECTED BY OWNER. 32. CONTRACTOR SHALL COORDINATE ALL NEW CABINETRY, MILLWORK, EQUIPMENT, AND FINISHES WITH OWNER. 33. ALL NEW DRYWALL SHALL BE SMOOTH FINISH UNLESS OTHERWISE NOTED. 34. ALL DOOR AND WINDOW FRAMES SHALL BE CAULKED AROUND ENTIRE PERIMETER. 35. PROVIDE 2 X 4 BLOCKING AT PERIMETER OF ALL DOOR AND WINDOW OPENINGS. 36. IT IS NOT WARRANTED THAT THE EXISTING CONDITIONS SHOWN ARE REPRESENTATIVE OF ACTUAL EXISTING CONDITIONS. ENGINEER ASSUMES NO RESPONSIBILITY FOR EXISTING CONDITIONS WHICH ARE SHOWN ONLY FOR REFERENCE. CONTRACTOR TO VERIFY ALL CONDITIONS, MEASUREMENTS, & ELEVATIONS BEFORE START OF CONSTRUCTION OR FABRICATION. INFORM ENGINEER IN WRITING OF ANY DISCREPANCIES. 37. UNLESS OTHERWISE NOTED, DIMENSIONS ARE GIVEN TO FACE OF STUD & FACE OF CMU, TYPICALLY. 38. WHERE NEW CONSTRUCTION ABUTS EXIST. CONSTRUCTION THAT IS TO REMAIN, ALL ADJACENT MATERIALS & FINISHES SHALL BE REPAIRED & REFINISHED TO LIKE NEW FINISH. 39. WHERE EXISTING CEILING, WALLS & FLOORS HAVE BEEN DAMAGED DUE TO DEMOLITION & NEW CONSTRUCTION UNDER THIS CONTRACT, CONTR. SHALL REPAIR & REFINISH AS REQ'D. TO LIKE NEW FINISH. 40. EXISTING CONDITIONS SHALL BE FIELD MEASURED/VERIFIED PRIOR TO CONSTRUCTION. 41. CONTRACTOR SHALL ERECT DUST/SECURITY BARRIERS AS REQ'D FOR DURATION OF CONTRACT. BARRIERS SHALL CONSIST OF 2x4 CONSTRUCTION W/ \" OSB OR PLYWD ONE SIDE FOR SECURITY PURPOSES & VISQUEEN ON CONSTRUCTION SIDE FOR DUST CONTROL. EXTEND DUST/ SECURITY WALL FROM FLOOR TO EXIST GWB CLG, TYPICALLY. 42. FIELD VERIFY ALL CONDITIONS, INCLUDING UNDERGROUND WHENEVER POSSIBLE. 43. TERMITE TREAT FOR SUBTERRANEAN TERMITES BENEATH FLOOR SLABS ON GRADE FILL AND ALONG EXTERIOR OF ALL FOUNDATION WALLS. 44. ASSUMED SOIL BRG. PRESSURE IS 1500 PSF. 45. PROPORTIONING OF REINFORCED CONCRETE MEMBERS & THEIR STEEL REINFORCING ARE BASED ON AN ULTIMATE STRENGTH DESIGN IN ACCORDANCE W/ "BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE", ACI 318-83. 46. ALL CONCRETE SHALL BE CLASSIFIED AS NORMAL WEIGHT W/ A UNIT WT. OF 145 PCF AND 3,000 PSI. 47. ALL REINFORCING SHALL COMPLY WITH ASTM 615 GRADE 60, DEFORMRD. 48. UNLESS NOTED, LAP ALL HORIZONTAL BARS 30 DIAMETERS AND ALL VERTICAL BARS 24 DIAMETERS. 49• HORIZONTAL REINFORCEMENT IN FOOTINGS, TURNDOWN SLABS & WALLS SHALL BE CONTINUOUS AROUND CORNERS. 50. CONTRACTOR TO PROVIDE ALL NECESSARY BRACING AND SHORING DURING CONSTRUCTION. 51. MASONRY CONCRETE UNITS SHALL BE 8" CMU. 52. LUMBER SHALL COMPLY WITH PS 20 SOFTWOOD LUMBER STANDARDS. ALL LUMBER SHALL BE S4S SEASONED LUMBER WITH 19% MOISTURE CONTENT. 53. STRUCTURAL LUMBER SHALL BE NO. 2 YELLOW PINE, Fb= 1200 PSI. 54. CONSTRUCTION PANELS SHALL COMPLY WITH AMERICAN PLYWOOD ASSOCIATION AND MARKED WITH APA STAMP. 55. GYPSUM WALL BOARD SHALL COMPLY TO ASTM 36, 1 /2" THICK WITH TAPERED EDGES. GENERAL CONTRACTOR SHALL SELECT GYPSUM WALL FINISH. 56. ROOF ASSEMBLY SHALL COMPLY WITH FLORIDA BUILDING CODE SECTION 104.2.1.1. ROOF ASSEMBLY TO BE DESIGNED & PERMITTED BY TRUSS MANUFACTURER. 57. A FOUNDATION SURVEY SHALL BE PERFORMED AND A COPY OF THE SURVEY SHALL BE ON THE SITE FOR THE BUILDING INSPECTOR USE. OR, ALL PROPERTY MARKERS SHALL BE EXPOSED AND A STRING STRETCHED FROM MARKER TO MARKER TO VERIFY REQUIRED SETBACKS. 58. ALL PLUMBING, ELECTRICAL, AND MECHANICAL ROUGH -INS MUST BE COMPLETE, INSPECTED AND APPROVED BEFORE REQUESTING THE FRAMING INSPECTION IN ACCORDANCE WITH 2O17 FLORIDA BUILDING CODE (6TH ADDITION). 59• CONTRACTOR TO VERIFY STRUCTURAL INTEGRITY OF EXIST. WALLS, BEAMS, COLUMNS, ETC. BEFORE REMOVAL OR DEMOLISHING. AN INSPECTION BY A STRUCTURAL ENGINEER MAYBE REQUIRED BEFORE COMMENCEMENT OF CONSTRUCTION. 60. ALL EXISTING STRUCTURAL MEMBERS SUCH AS WALLS, BEAMS, COLUMNS, ROOF, FOUNDATION, ETC. TO BE VERIFIED BY STRUCTURAL ENGINEER PRIOR TO CONSTRUCTION. SOIL TREATMENT FOR TERMITES 1. A PERMANENT SIGN WHICH IDENTIFIES THE TREATMENT PROVIDER & NEED FOR RE -INSPECTION & TREATMENT CONTRACT RENEWAL SHALL BE PROVIDED. SIGN SHALL BE POSTED NEAR WATER HEATER, OR ELECTRICAL PANEL. 2. CONDENSATE AND ROOF DOWNSPOUTS SHALL DISCHARGE AT LEAST 1'-0" AWAY FROM THE BUILDING SIDE WALLS. 3. IRRIGATION/ SPRINKLER SYSTEM INCLUDING ALL RISERS 8c SPRAY HEADS SHALL NOT BE INSTALLED WITHIN 1'-0" OF THE BUILDING SIDE WALLS. 4. TO PROVIDE FOR INSPECTION OF TERMITE INFESTATION, SEPARATION BETWEEN WALL COVERING 8c FINAL EARTH GRADE SHALL NOT BE LESS THAN 6 INCHES. EXCEPTION: PAINT OR CEMENTITIOUS FINISH < THAN 5/8" THICK APPLIED DIRECTLY TO FOUNDATION WALL 5. INITIAL TREATMENT SHALL BE DONE AFTER ALL EXCAVATION AND BACKFILL IS COMPLETE. 6. SOIL DISTURBED AFTER THE INITIAL TREATMENT SHALL BE RE TREATED INCLUDING SPACED BOXED OR FORMED. 7. BOXED AREAS IN CONCRETE FLOORS FOR SUBSEQUENT INSTALLATION OF TRAPS, ETC., SHALL BE MADE WITH PERMANENT METAL OR PLASTIC FORMS. PERMANENT FORMS MUST BE OF A SIZE 8c DEPTH THAT WILL ELIMINATE THE DISTURBANCE OF SOIL AFTER THE INITIAL TREATMENT. 8. A 10-MIL. MINIMUM VAPOR RETARDER MUST BE INSTALLED TO PROTECT AGAINST RAINFALL DILUTION. IF RAINFALL OCCURS BEFORE VAPOR RETARDER PLACEMENT, RETREATMENT IS REQUIRED. 9. CONCRETE OVERPOUR & MORTAR ALONG FOUNDATION PERIMETER MUST BE REMOVED BEFORE EXTERIOR TREATMENT. 10. APPLY SOIL TREATMENT UNDER ALL EXTERIOR CONCRETE OR GRADE WITHIN 1'-0" OF STRUCTURE SIDEWALLS. 11- AN EXTERIOR VERTICAL CHEMICAL BARRIER MUST BE INSTALLED AFTER CONSTRUCTION IS COMPLETE INCLUDING LANDSCAPING 8c IRRIGATION. ANY SOIL DISTURBED AFTER THE VERTICAL BARRIER IS APPLIED SHALL BE RETREATED. 12. ALL BUILDINGS ARE REQUIRED TO HAVE PRE -CONSTRUCTION TREATMENT. 13. A CERTIFICATE OF COMPLIANCE MUST BE ISSUED TO BUILDING DEPARTMENT BY A LICENSED PEST CONTROL COMPANY BEFORE A 0.0. WILL BE ISSUED. CERTIFICATE OF COMPLIANCE SHALL STATE "THE BUILDING HAS RECEIVED A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN TERMITES. THE TREATMENT IS IN ACCORDANCE WITH THE RULES & LAWS OF THE FLORIDA DEPARTMENT OF AGRICULTURE & CONSUMER SERVICES." 14- AFTER WORK IS COMPLETED, LOOSE WOOD & FILL MUST BE REMOVED FROM BELOW & WITHIN 1'-0" OF BUILDING. INCLUDING ALL GRADE STAKES, TUB TRAP BOXES, FORMS, SHORING, OR OTHER CELLULOSE CONTAINING MATERIAL. 15. NO WOOD, VEGETATION, STUMPS, CARDBOARD, TRASH, ETC., SHALL BE BURIED WITHIN '5'-0" OF ANY BUILDING OR PROPOSED BUILDING. PROPOSED INTERIOR BUILD -OUT AT: 5915 Gall Blvd, Zephyrhills, FL 33542 OWNER NAME: ZEPHYR LLC OWNER ADDRESS: 7162 READING RD STE 730 CINCINNATI, OH 45237-3845 PROFESSIONAL SERVICES BY: GLOBAL CONSULTING ENGINEERS, INC. Dead Jot sullo o GasStation0 ul G x gaIV 1P Rd 0, Rd North Ave North Ave 0, ' K & K Glass, I s r �w Laundry USA w 011ie's Bargain OtItlet i iscount tcr. Pet Supplies IVI rion Smith Florist Pius Z phyrhills Delivery Sunrise Eatery s4 � T €� Sl ell's Killer Bakery SITE-LOCA110LA Hart cl� 9 Tai�e��_J Adkins 0 Pet Hospital T - Wellspring Tree Lane Village ,.. �. itd LlVit� Mobile Horne - All � ,, AbOUt , Salon Day Spa R.. 4 sc, y, I5th Ave . ALL WORK SHALL COMPLY WITH PREVAILING CODES FLORIDA BUILDING CODE, NATIONAL ELECTRIC CODE, DRAWING ABBREVIATIONS AND THE CITY OF ZEPHYRHILLS A.B. ANCHOR BOLT DET. DETAIL GYP. GYPSUM PSI PER SQUARE INCH ORDINANCES A. C. AIR CONDITIONING DIA. DIAMETER HGT. HEIGHT REF. REFERENCE ACOUST. ACOUSTICAL DIM. DIMENSION HDWE. HARDWARE REINF. REINFORCED ADD'N. ADDITION DN. DOWN HM. HOLLOW METAL R/C REINFORCED CONCRETE ADMIN. ADMINISTRATION DRYW DRYWALL INFO INFORMATION A.F.F. ABOVE FINISHED FLOOR DS. DOWNSPOUT INSUL. INSULATION RM. ROOM DWGS. DRAWINGS JT. JOINT SCHED. SCHEDULE ALT. ALTERNATE EA. EACH LAM. LAMINATED SC. SOLID CORE n(� ALUM. ALUMINUM EIFS EXTERIOR INSULATING LAV. LAVATORY SECT. SECTION(S) i"11 /i ANCH. ANCHOR FINISH SYSTEM MACH. MACHINE SH. SHEET *AV`)A "Ti: ACT. ACOUSTICAL CEILING TILE ELECT. ELECTRICAL MANUF. MANUFACTURER SIM. SIMILAR tX1;°V--s ZCMYINrHIL ELEV. ELEVATION MATL. MATERIAL SS. STAINLESS STEEL o11 AWV,,; OMCIAL ® AT EQ. EQUAL MAX. MAXIMUM STL. STEEL BLK. BLOCK EWC. ELECTRIC WATER COOLER MECH. MECHANICAL STD. STANDARD BD. BOARD MIN. MINIMUM STRUCT. STRUCTURAL BM. BEAM EXIST, EXISTING M.O. MASONRY OPENING TELE. TELEPHONE BOTT. BOTTOM EXT. EXTERIOR M.R. MOISTURE RESISTANT TH. THICK(ENED) BRG. BEARING EXP. EXPANSION MET. METAL TYP. TYPICAL B.U.R. BUILT UP ROOF F&I FURNISH AND INSTALL NIC. NOT IN CONTRACT T.O.W. TOP OF WALL C.J. CONTROL JOINT FIBERGL. FIBERGLASS NO. NUMBER T.O.S. TOP OF STEEL CLG. CEILING F.D. FLOOR DRAIN NTS. NOT TO SCALE UL UNDERWRITERS CLR. CLEAR F.E. FIRE EXTING. O.C. ON CENTER LABORATORIES CMU. CONCRETE MASONRY UNIT FIN. FINISH O.D. OUTSIDE DIAMETER UNO UNLESS NOTED FLASH'G. FLASHING OFF. OFFICE OTHERWISE COL. COLUMN FL. FLOOR OPG. OPENING VCT VINYL COMPOSITION CONC. CONCRETE FTG. FOOTING OPP. OPPOSITE TILE CONT. CONTINUOUS FURN. FURNISH PART. PARTITION VERT. VERTICAL CONSTR. CONSTRUCTION GA. GAUGE PAV'T. PAVEMENT W/ WITH C.T. CERAMIC TILE GALV. GALVANIZED P.T. PRESSURE TREATED W.W.F. WELDED WIRE FABRIC COORD. COORDINATE GWB GYPSUM WALL BOARD PTD. PAINTED CHLORIDE W. WIDTH DBL. DOUBLE PVC POLY VINYL WD. WOOD SCOPE OF WORK &PERMIT REFERENCE: NEW INTERIOR BUILDOUT IN AN EXISTING 1,072 SF RETAIL SPACE IN EXISTING SHELL SPACE. TENANT CONTRACTOR NOTE TENANT/ GENERAL CONTRACTOR MUST AQUIRE LAND LORD'S APPROVAL OF THE PROPOSED DESIGN/ WORK IN WRITING BEFORE THE START OF ANY WORK. LEGAL DESCRIPTION SITE: PARCEL ID: 10-26-21-0020-00000-0100 PINE GROVE PB 2 PG 15 COM SW COR LOT 10 FOR POB TH NO2DG 02' 12"W 172.00 FT TH N88DG 28' WE 623.71 FT TH S02DG 02' WE 47.00 FT TH S88DG 28' 05"W 93.00 FT TH S02DG 02' 10"E 60.00 FT TH N88DG 28' 05"E 93.00 FT TH S02DG 02' 12"E 65.00 FT TH S88DG 28' 05"W 630.08 FT TO POB LESS THAT POR DESC IN OR 9679 PG 2653 LYING WITHIN OR 4341 PG 1041 CODE INFORMATION FLORIDA BUILDING CODE, 2020 (7TH EDITION) ALL WORK SHALL CONFORM TO THE FOLLOWING CODES AS WELL AS ALL LOCAL ORDINANCES AUTHORITIES HAVING LOCAL JURISDICTION: FLORIDA EXISTING BUILDING CODE 2020 EDITION FLORIDA ENERGY CONSERVATION CODE 2020 EDITION FLORIDA MECHANICAL CODE 2020 EDITION FLORIDA CODE FUEL GAS 2020 EDITION FLORIDA PLUMBING CODE 2020 EDITION FLORIDA FIRE PREVENTION CODE 2020 EDITION NFPA 1 UNIFORM FIRE CODE 2018 EDITION NFPA 101 LIFE SAFTY CODE 2018 EDITION NFPA 70-17 NAT'L ELECTRICAL CODE 2017 EDITION NFPA 72-18 NAT'L FIRE ALARM CODE 2018 EDITION FLORIDA ACCESSIBILITY CODE 2020 EDITION (COMBINES FL. AMERICANS W\ DISABILITIES ACT & FED. ADA LAW) BUILDING DATA BUILDING LOCATION RIVERVIEW/ HILLSBOROUGH COUNTY EXISTING ZONING OOSD PROPERTY USE MERCANTILE (GENERAL RETAIL) EXISTING OCCUPANCY VACANT SHELL PROPOSED OCCUPANCY "M" MERCANTILE (RETAIL STORE) LAND AREA 2.13 ACRES EXISTING SHELLBUILDING AREA 14,024 S.F. PROPOSED BUILDOUT AREA 1,072 S.F. MAXIMUM AREA ALLOWED 12,500 S.F. EXISTING BUILDING HEIGH 16'-0" MAXIMUM HEIGHT ALLOWED 35' TYPE OF CONSTRUCTION TYPE VB UNSPRINKLED UNPROTECTED, FIRE ALARM NO MEANS OF EGRESS/ MAX OCCUPANT LOAD: FBC - BUILDING, CHAPTER 10 FLOOR AREA PER OCCUPANT TABLE 1004.1.2: TOTAL OCCUPANT LOAD = 1072 / 60 SF PER PERSON =18 PERSONS PARKING REQUIREMENTS. PARKING REQUIREMENT: 5 SPACES PER 1,000 SF 1,072 / 1000 * 5 = 6 SPACES REQUIRED 270 SHARED SPACES PROVIDED WIND DESIGN CRITERIA: (ASCE7-10) BASIC WIND SPEED: 140 MPH (3 SEC. GUST) WIND EXPOSURE: "C" BUILDING RISK CATEGORY II ENCLOSED BUILDING INTERNAL PRESSURE COEFFICIENT, P = qh [(GCp) - (GCpi)] GCpi = +/- 0.18 CORNER DISTANCE = 8.0 FT COMPONENTS AND CLADDING WIND PRESSURES = SEE TABLES NET WIND UPLIFT = -0.6DL + WL GRAVITY DESIGN LOADS: ROOF LIVE LOAD: 20 PSF ASSUMED ROOF DEAD LOAD: 20 PSF (37 PSF AT TOWERS). ASSUMED DESIGN SOIL BRG PRESSURE: 2,000 PSF (GC VERIFY) COMPACT TO 95% OF THE MODIFIED PROCTOR DRY DENSITY SITE NOTES 1. CONTRACTOR SHALL VERIFY FIELD CONDITIONS AND CAREFULLY COMPARE SUCH FIELD MEASUREMENTS AND CONDITIONS AND OTHER INFORMATION KNOWN TO THE CONTRACTOR WITH THE DRAWINGS BEFORE COMMENCING WORK ACTIVITIES. ERRORS, INCONSISTENCIES OR OMISSIONS DISCOVERED BY OR MADE KNOWN TO THE CONTRACTOR SHALL BE PROMPTLY REPORTED TO THE ENGINEER. CONTRACTOR'S COMMENCEMENT OF WORK SHALL CONSTITUTE T U E ACCEPTANCE OF EXISTING CONDITIONS. 2. CONTRACTOR SHALL REMOVE ALL DEBRIS, TREES, VEGETATION AND ORGANIC MATTER IN ORDER TO PREPARE THE SITE FOR DEVELOPMENT. 3. CONTRACTOR SHALL CONNECT ALL POTABLE WATER LINES FIRE LINES AND SEWER LINES TO EXISTING WATER, FIRE AND SEWER LATERALS. 4. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS BEARING THEIR REVIEW STAMP. TO THE ENGINEER FOR REVIEW OF ALL PRE -MANUFACTURED COMPONENTS PRIOR TO FABRICATION &/OR PURCHASE. ALLOW 10 BUSINESS DAYS FOR REVIEW. HANDICAP ACCESSIBILITY NOTES THE DESIGN OF SPACES DEPICTED IN THESE DRAWINGS COMPLIES WITH THE ACCESSIBILITY REQUIREMENTS OF THE 2020 FLORIDA BUILDING CODE 6TH EDITION. BUILDING SHALL INCLUDE AN ACCESSIBLE ROUTE FOR THE PUBLIC FROM ACCESSIBLE PARKING SPACES TO ENTRY DOORS AND INTO THE BUILDING. ALL PUBLIC AREAS ARE ACCESSIBLE AND HAVE NO LEVEL CHANGES GREATER THAN j " EXCEPT AS PROVIDED BY RAMP. SHEET INDEX 1 - CS.1 COVER SHEET. 2 - G1.1 PROPOSED FLOOR PLAN & DETAILS. 3 - G1.2 LIFE SAFETY & REFLECTED CEILING PLANS. 4 - G1.3 ENLARGED RESTROOMS PLANS AND DETAILS. 5 - G1.4 SCHEDULES AND DETAILS. 6 - P-1 PLUMBING PLAN DETAILS. 7 - P-2 PLUMBING RISER DIAGRAMS. 8 - M-1 MECHANICAL PLAN. 9 - E-1 ELECTRICAL POWER & LIGHTING PLANS. 10- E-2 ELECTRICAL NOTES AND SPECS. 11- E-3 ELECTRICAL SPECIFICATIONS BEFORE PERMITTING OR START OF CONSTRUCTION: 1. TENANT TO ACQUIRE LANDLORD WRITTEN APPROVAL OF ALL PROPOSED ALTERATIONS. 2. CONTRACTOR TO VERIFY ALL EXISTING DIMENSIONS AND ELEVATIONS. 3. CONTRACTOR TO COORDINATE ROUGH WINDOW/ DOOR OPENINGS SIZE W/ MFR SPECS ISSUED FOR: REVIEW 11.12.2021 z O o' U U) w 0 xw>_w_0zM O Ln -� co q � � O � W � � a N W � O (� W � z L;j > a z 0 0 J Lo U U z Q_ U) Lp::� �O � U co 0z m�I O �{ a® F' O z W �l co rr CrD w a� 0 H (f a E- �� 6 w ✓(\ i1�1 m O fs-� Ld ai T Q o 62 Gw,ffFi7 COA. NO.29116 MAZEN PE. MAR,if, (FL. P I# 691 6) o Q w cn W cn v O w -' w ,F �- 0w SHEET 7z L 17 GENERAL NOTES 1. THESE DRAWINGS ARE THE PROPERTY OF GLOBAL CONSULTING ENGINEERS, INC. AND SHALL NOT BE USED, REPRODUCED, OR ALTERED IN ANY WAY WITHOUT THE PRIOR EXPRESSED WRITTEN CONSENT. ANY CHANGES, DELETIONS OR ADDITIONS TO THESE DRAWINGS WITHOUT CONSENT IS STRICTLY PROHIBITED. 2. ANY AND ALL ITEMS REQUIRED TO FURNISH A COMPLETE CONSTRUCTION, BUT NOT SPECIFICALLY SHOWN OR SPECIFIED ON THE DRAWINGS SHALL BE FURNISHED AND INSTALLED IN CONFORMANCE TO THE FLORIDA BUILDING CODE AND LOCAL ORDINANCES AND IN GOOD WORKMANLIKE MANNER. 3. IT IS NOT THE INTENT OF THESE DRAWINGS TO SHOW EVERY DETAIL OF CONSTRUCTION. THE CONTRACTOR IS EXPECTED TO FURNISH AND INSTALL ALL ITEMS REQUIRED TO COMPLETE THE WORK. 4. THE ENGINEER IS NOT RESPONSIBLE FOR THE EXISTING BUILDING, BUILDING UTILITIES OR WORK NOT SPECIFICALLY SHOWN OR SPECIFIED ON THESE DRAWINGS. 5. THE CONTRACTOR SHALL PROVIDE ALL REQUIRED BUILDING PERMITS, INSURANCES, LICENSES, TAXES, ETC. REQUIRED TO PERFORM THE WORK OUTLINED IN THE DRAWINGS. 6. THE CONTRACTOR SHALL COORDINATE/ SUPERVISE ALL WORK PERFORMED BY HIS FORCES AND BY SUBCONTRACTORS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION AND VERIFICATION WITH OTHER TRADES TO ASSURE COMPLIANCE WITH APPROVED DRAWINGS. 7. CONTRACTOR SHALL VISIT SITE & VERIFY BUILDING DIMENSIONS & SIZES & LOCATIONS OF ALL MECHANICAL, PLUMBING, ELECTRICAL EQUIPMENT BEFORE COMMENCING OF WORK. 8. THE CONTRACTOR SHALL COORDINATE ALL PARKING, STORAGE, TRASH REMOVAL, ETC. WITH THE OWNER OR BUILDING MANAGER. 9. ABBREVIATIONS NOTED IN THE DRAWINGS OR SPECIFICATIONS ARE THOSE COMMONLY USED. THE ENGINEER WILL DEFINE ANY ABBREVIATION QUESTIONED UPON REQUEST. 10. THE CONTRACTOR SHALL PROVIDE ALL NECESSARY TEMPORARY BARRIERS, LIGHTING, COVERING, BRACING, SHORING, FIRE PREVENTION AND OTHER EQUIPMENT NECESSARY TO PROTECT THE SAFETY AND SECURITY OF ALL PERSONS AND THE PROPERTY THROUGHOUT THE ENTIRE PERIOD OF CONSTRUCTION. 11. THE CONTRACTOR SHALL REPAIR OR REPLACE ANY EXISTING FINISHES AND/OR ANY ITEMS DAMAGED DURING CONSTRUCTION TO MATCH THE ADJACENT EXISTING. 12. THE PLANS ARE NOT TO BE SCALED. THE PLANS AND DIAGRAMS SHOW RELATIVE LOCATIONS AND ACTUAL EXISTING LOCATIONS MAY VARY IN THE FIELD. 13. THE CONTRACTOR SHALL REVIEW EXISTING BUILDING SYSTEMS AND UTILITIES AS TO THEIR COMPLIANCE WITH THE FLORIDA BUILDING CODE AND OTHER APPLICABLE CODES AND NOTIFY THE ENGINEER OF ANY NON -CONFORMING ITEMS FOUND. 14. SECTIONS AND DETAILS SHOWN TYPICAL ON THE PLANS MAY NOT BE SPECIFICALLY NOTED AT EACH APPLICABLE LOCATION. HOWEVER, THESE DETAILS MAY BE APPLICABLE OR MAY BE REQUIRED IN MORE THAN ONE LOCATION. 15. THE CONTRACTOR SHALL COORDINATE HIS CONSTRUCTION SCHEDULES, PLANNED POWER OUTGOS, NIGHTTIME WORK, WEEKEND WORK AND WORK IN OTHER ADJACENT TENANT SPACES WITH THE OWNER PRIOR TO PERFORMING THE WORK. 16. THE CONTRACTOR SHALL SUPPLY THE OWNER WITH ALL EQUIPMENT MANUALS AND WARRANTIES. 17. THE CONTRACTOR SHALL GUARANTEE IN WRITING ALL MATERIALS AND LABOR FOR A PERIOD OF ONE YEAR FROM THE DATE OF FINAL ACCEPTANCE BY THE OWNER AND WILL AT HIS OWN COST REPAIR OR REPLACE ALL WORK OR DAMAGES CAUSED BY THE WORK WHICH BECOMES DEFECTIVE DURING THE TERM OF THE GUARANTEE. AND OTHER SPECIFIC REQUIREMENTS MAY BE MODIFIED OR EXTENDED BY THE OWNER/CONTRACTOR AGREEMENT. 18. WHERE DISSIMILAR METALS COME IN CONTACT, THE CONTRACTOR SHALL PROVIDE PROPER INSULATION TO PREVENT GALVANIC OR ELECTROLYTIC ACTION AS WELL AS VIBRATION OR NOISE TRANSMISSION. 19. THE CONTRACTOR SHALL PROVIDE THE OWNER WITH A SET OF AS BUILT DRAWINGS INDICATING ALL FILED CHANGES, ADDITIONS OR DELETIONS MADE DURING CONSTRUCTION. 20. ALL DEMOLITION SHALL BE COORDINATED WITH THE OWNER PRIOR TO PERFORMING THE WORK. 21. ALL NEW MATERIALS/EQUIPMENT SHALL HAVE U.L. (UNDERWRITER'S LABORATORY) APPROVED LABELS AS ACCEPTED BY LOCAL AUTHORITY. 22. ELECTRICAL CONTRACTOR SHALL COORDINATE ALL HIS WORK WITH THE UTILITY COMPANIES TO ASSURE THAT IT COMPLIES WITH THEIR REQUIREMENTS. 23. ALL WORK PERFORMED UNDER THIS CONTRACT SHALL COMPLY WITH ALL NATIONAL, STATE, AND LOCAL CODES HAVING JURISDICTION AND WITH ALL REQUIREMENT'S OF THE UTILITY COMPANIES WHOSE SERVICES SHALL BE USED. 24. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS AND SHALL NOTIFY THE ENGINEER IF ANY DISCREPANCIES ARE DISCOVERED OR DEVIATIONS FROM THE APPROVED PLANS REQUIRED BEFORE PROCEEDING WITH THE WORK INVOLVED. COMMENCEMENT OF THE WORK SHALL CONSTITUTE ACCEPTANCE OF EXISTING CONDITIONS. 25. IF DOUBT EXISTS IN THE MIND OF THE BIDDER AS TO THE TRUE MEANING OF ANY PART OF THESE CONSTRUCTION DRAWINGS, BIDDER MUST REQUEST THE INFORMATION IN WRITING FROM THE ENGINEER IMMEDIATELY. 26. ALL SHOP DRAWINGS SHALL BE SUBMITTED W/ CONTRACTOR'S REVIEW STAMP TO THE ENGINEER FOR APPROVAL PRIOR TO FABRICATION. ALLOW 10 BUSINESS DAYS FOR REVIEW. 27. ANY SUBSTITUTIONS MUST BE REVIEWED AND APPROVED IN WRITTING BY THE ENGINEER PRIOR TO FABRICATION OR PURCHASING. 28. ALL WOOD IN CONTACT WITH MASONRY, CONCRETE, OR EXPOSED TO WEATHER SHALL BE PRESSURE TREATED. 29. ALL MATERIALS SHALL HAVE A MINIMUM CLASS "C" FLAME SPREAD RATING. 30. PROVIDE ONE TYPE ABC RATED FIRE EXTINGUISHER PER EVERY 3000 SQUARE FT OR FRACTION THEREOF OF BUILDING AREA. (PROVIDE 2 MIN.) 31. ALL NEW WALLS SHALL RECEIVE ONE COAT OF PRIMER PRIOR TO RECEIVING TWO COATS OF INTERIOR LATEX PAINT. COLOR AS SELECTED BY OWNER. 32. CONTRACTOR SHALL COORDINATE ALL NEW CABINETRY, MILLWORK, EQUIPMENT, AND FINISHES WITH OWNER. 33. ALL NEW DRYWALL SHALL BE SMOOTH FINISH UNLESS OTHERWISE NOTED. 34. ALL DOOR AND WINDOW FRAMES SHALL BE CAULKED AROUND ENTIRE PERIMETER. 35. PROVIDE 2 X 4 BLOCKING AT PERIMETER OF ALL DOOR AND WINDOW OPENINGS. 36. IT IS NOT WARRANTED THAT THE EXISTING CONDITIONS SHOWN ARE REPRESENTATIVE OF ACTUAL EXISTING CONDITIONS. ENGINEER ASSUMES NO RESPONSIBILITY FOR EXISTING CONDITIONS WHICH ARE SHOWN ONLY FOR REFERENCE. CONTRACTOR TO VERIFY ALL CONDITIONS, MEASUREMENTS, & ELEVATIONS BEFORE START OF CONSTRUCTION OR FABRICATION. INFORM ENGINEER IN WRITING OF ANY DISCREPANCIES. EGRESS FLOOR LEVEL NOTES: 1. LEVEL CHANGE AT DOORS SHALL NOT EXCEED 1/2" PER 11-4.13 F.B.C. 2. DIFFERENCE IN FLOOR LEVEL BETWEEN OPPOSITE SIDES OF EGRESS DOORS SHALL NOT EXCEED 1/2". (N.F.P.A. 101 - 7.2.1.3) ACCESSIBILITY NOTES THE DESIGN OF SPACES DEPICTED IN THESE DRAWINGS COMPLIES WITH THE ACCESSIBILITY REQUIREMENTS OF THE FLORIDA BUILDING CODE 2017 (6th EDITION). BUILDING SHALL INCLUDE AN ACCESSIBLE ROUTE FOR THE PUBLIC FROM ACCESSIBLE PARKING SPACES TO ENTRY DOORS & INTO THE BUILDING. ALL PUBLIC AREAS ARE ACCESSIBLE & HAVE NO LEVEL CHANGES GREATER THAN j" EXCEPT AS PROVIDED BY RAMP. SLAB NOTES 1. REPAIR SLAB -ON -GRADE WITH 4" THICK (3000 PSI) P.I.P CONCRETE EXCEPT WHERE NOTED. REINFORCE W/ 6x6 - W1.4xW1.4 W.W.F. (PROVIDED IN SHEETS) OVER 10 MIL . VAPOR RETARDER (LAP 6" AND TAPE SEAMS) OVER WELL COMPACTED TREATED SOIL. 2. CJ= PROVIDE SLAB CONTROL JOINTS AT 8'-0" MAX. CONTRACTOR NOTE: ALL DIMENSIONS ARE TO THE APPROXIMATE INCH. IF THERE IS A MAJOR DISCREPANCY REGARDING A DIMENSION PLEASE CONTACT THE OWNER OR ENGINEER. ALL INTERIOR CABINETS , PLUMBING FIXTURES, LIGHT FIXTURES ETC. TO BE DETERMINED BY OWNER COORDINATE ALL RADIUSED CORNERS WITH OWNER. IMPORTANT NOTE TO ELECTRICAL & PLUMBING CONTRACTORS: ALL PLUMBING PIPING ELECTRICAL CONDUITS SWITCHES & OUTLETS SHALL BE MADE OF NON- COMBUSTIBLE MATERIALS & SEALED TIGHT OR BE RUN IN A SECONDARY FRAME WALL ADJACENT TO FIRE WALL. EXISTING TENANT WALL FINISH. F.V. EXISTING 8" MASONRY WALL FMCI NEW GYPSUM WALLBOARD ON 1X2 P.T. FURRING STRIPS ON R5 L-FOIL (CONT.) BOARD. PROVIDE 1x 2 P.T. FIRE STOPS ® WALL MIDHT. NOT TO EXCEED 8'-0" HORIZ. OR VERTICALLY. WALL TYPE 'A' NOTES: 1. ALL MATERIALS SHALL HAVE A MINIMUM CLASS "C" FLAME SPREAD RATING. 2. PROVIDE ONE TYPE ABC RATED FIRE EXTINGUISHER PER EVERY 3000 S.F. OR FRACTION THEREOF OF BUILDING AREA. (PROVIDE 2 MIN.) 3. ALL NEW WALLS SHALL RECEIVE ONE COAT OF PRIMER PRIOR TO RECEIVING TWO COATS OF INTERIOR LATEX PAINT. COLOR AS SELECTED BY OWNER. 4. CONTRACTOR SHALL COORDINATE ALL NEW CABINETRY, MILLWORK, EQUIPMENT AND FINISHES WITH OWNER. 5. ALL NEW DRYWALL SHALL BE SMOOTH FINISH UNLESS OTHERWISE NOTED. MINIMUM INTERIOR FINISH CLASSIFICATION OCCUPANCY UNSPRINKLERED EXIT OTHER SPACES EXITS ICORRIDORS GROUP M, MERCANTILE A A C ODOOR NUMBER Cf>-WNDOW TYPE NEAMMEE WALL SECTION TYPE # APPEARS WALL TYPE ON SHEET # DESIGNATION SECTION DESIGNATION STUDS" ® 24 20GA O/C MAX. �" GYP. BD. INTERIOR WALL WALL TYPE 'B' #10 WIRE 2 16' O.C, MAX, WITH (B) TWISTS MIN, / DIAGONAL BRACES 2 6'-0/ ❑,C, MAX, TO ROOF STRUCT. \ TO ROOF STRUCT. T� SEE REFLECTED J I0I CEILING PLANS WALL METAL STUDS PER PLANS, CONT. BLOCKING AT MIDHEIGHT +111 1 ITERIOR PARTITION BRACE 6", "20GA. STUDS-J ® 24" O/C MAX. NEW 1/2" GYPSUM BOARD PLUMBING WALL PLUMBING WALL TYPE 'Cl WALL LEGEND TYPE SECTION DESCRIPTION FIRE RATING REMARKS ❑A 8" REINFORCED MASONRY WALL 1-HR ■101 1 10 1 ImlEXISTING NEW NON BEARING PARTITION (3 1/2" 24GA ® 16" O.C.) TO 6" ABOVE CEILING NA © NEW NON BEARING PLUMBING WALL (6" 20GA ® 16" O.C.) TO 6" ABOVE CEILING NA ALL DIMENSIONS & ELEVATIONS ARE EXISTING TO BE VERIFIED IN FIELD ROOM FINISH SCHEDULE (COORDINATE AND CONFIRM WITH TENANT) ROOM NAME FLOOR BASE WALLS CEILING REMARKS NUMBER NUMBER NAME NORTH SOUTH EAST WEST 101 RETAL-AREA TILE -TT BASE -B1 PAINTED GYP. BD PAINTED Gyp. BD LATEX EPDXY WATERPROOF PAINT ON PAINTED GYP. � EXPOSED FOAM BLACK) COORDINATE COLORS AND EXACT 101 GYP. BOARD INSULATION ON MTTLL. DECCK MODELS WITH OWNER 102 BACK ROOM TILE-T7 BASE -B1 PAINTED GYP. BD (LATEX EPDXY WATERPROOF PAINTED GYP. BD PAINTED GYP. BO PAINTED GYP. BD EXPOSED FOAM (BLACK) COORDINATE COLORS AND EXACT 102 PAINT AT WET AREA INSULATION ON MTL. DECK MODELS WITH OWNER 103 RESTROOM TILE-TI BASE -B2 LATEX EPDXY WATERPROOF PAINT ON GYP. LAID( EPDXY WATERPROOF PANT ON GREEN LATEX EPDXY WATERPROOF PAINT ON LATEX EPDXY WATERPROOF PAINT ON PAINTED GYP. BD (8'-0) COORDINATE COLORS AND EXACT 103 GYP. BOARD GYP. BOARD GYP. BOARD MODELS WITH OWNER ROOM FINISH LEGEND ACT-1 ARMSiR0K SWAR EDGE 24X48 ACT-2 ARMSiRONG. FIRE RATED SQUAR EDGE 24X48 8-1 6' WOOD BASE PAINTED B-2 8' CERAMIC BASE T-1 12X12 CERAMIC TILE NEW 3-5/8" METAL STUDS FURRING 0 16" _ O.C. FOR THE WATER b FOUNTAIN PLUMBING ADJACENT TENANT SPACE: PIZZA HUT RESTAURANT EXISTING 2-HR 8 MASONRY WALLS. EXISTING 8" MASONRY WALLS. L 17'-3" EXIST. 3'4"X6'8" METAL DOOR. -\\ EXIST. 00 ID METER x 3 3'-.4". 6'-4" 2y2" EXIST. ELECT. PANEL G o) ' U °I� I SEX ..... . EXIST. " . �� �Tf�Q0 3 so.. 1 [03===' .3.0 X6 8._11� tl �. T 1iL__ ---- Ll 10'-Q" 7,-2„ EXIST: 4" SLAB ON GRADE -SEE, FINISH SCHEDULE COORDINATE ALL FINISHES .WITH ,TENANT. TYP. OX 1 X EXISTING o STOREFRONT 9'-8" 3'-0" 4'-6,V„ 2 18'-7' EXISTING SIDEWALK UNDER EXISTING CANOPY TO REMAIN -EXISTING CONC. STEPS TO BE REPLACED BY PRE-ENGINEERED METAL STEPS WITH LANDING AND RAILING BY OTHERS UNDER SEPARATE PERMIT. co ul) ADJACENT TENANT SPACE: EXIST. PET SUPPLY RETAIL EXISTING 2-HR 8" MASONRY WALLS PORPOSED FLOOR PLAN SCALE: 1 /4" = 1'-0" 0 BEFORE PERMITTING OR START OF CONSTRUCTION: 1. TENANT TO ACQUIRE LANDLORD WRITTEN APPROVAL OF ALL PROPOSED ALTERATIONS 2. CONTRACTOR TO VERIFY ALL EXISTING DIMENSIONS AND ELEVATIONS. 3. CONTRACTOR TO COORDINATE ROUGH WINDOW/ DOOR OPENINGS SIZE W/ MFR SPEC ISSUED FOR: REVIEW 11.12.2021 R. • n xw>_w_ozw � It O Lo Q co Z � � Q J IZ O � O W �rl O 0 W N x O f1 W > fy_ O a' � W z O F > a � o z .J L U z U w w H O O w ir m = IL a V) Lo t` O � U el v� I0 LoZ H I �o � E® o W z f--I w � cfl M a ti E) Q) a O Ey 6 a h�--I m LTO-+ O w ai a cQ w � a W JOB. N0. 21040 COA. NO.29116 MAZEN ARI E. (FL. P 60 6) -id: ui G1.1 1� e ( _3� __ c (�_ Y_ GENERAL NOTES ti J 1. THESE DRAWINGS ARE THE PROPERTY OF GLOBAL CONSULTING ENGINEERS, INC. AND SHALL NOT BE USED, REPRODUCED, OR ALTERED IN ANY WAY WITHOUT THE PRIOR EXPRESSED WRITTEN CONSENT. ANY CHANGES, DELETIONS OR ADDITIONS TO THESE DRAWINGS WITHOUT CONSENT IS STRICTLY PROHIBITED. 2. ANY AND ALL ITEMS REQUIRED TO FURNISH A COMPLETE CONSTRUCTION, BUT NOT SPECIFICALLY SHOWN OR SPECIFIED ON THE DRAWINGS SHALL BE FURNISHED AND INSTALLED IN CONFORMANCE TO THE FLORIDA BUILDING CODE AND LOCAL ORDINANCES AND IN GOOD WORKMANLIKE MANNER. 3. IT IS NOT THE INTENT OF THESE DRAWINGS TO SHOW EVERY DETAIL OF CONSTRUCTION. THE CONTRACTOR IS EXPECTED TO FURNISH AND INSTALL ALL ITEMS REQUIRED TO COMPLETE THE WORK. 4. THE ENGINEER IS NOT RESPONSIBLE FOR THE EXISTING BUILDING, BUILDING UTILITIES OR WORK NOT SPECIFICALLY SHOWN OR SPECIFIED ON THESE DRAWINGS. 5. THE CONTRACTOR SHALL PROVIDE ALL REQUIRED BUILDING PERMITS, INSURANCES, LICENSES, TAXES, ETC. REQUIRED TO PERFORM THE WORK OUTLINED IN THE DRAWINGS. 6. THE CONTRACTOR SHALL COORDINATE/ SUPERVISE ALL WORK PERFORMED BY HIS FORCES AND BY SUBCONTRACTORS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION AND VERIFICATION WITH OTHER TRADES TO ASSURE COMPLIANCE WITH APPROVED DRAWINGS. 7. CONTRACTOR SHALL VISIT SITE & VERIFY BUILDING DIMENSIONS & SIZES & LOCATIONS OF ALL MECHANICAL, PLUMBING, ELECTRICAL EQUIPMENT BEFORE COMMENCING OF WORK. 8. THE CONTRACTOR SHALL COORDINATE ALL PARKING, STORAGE, TRASH REMOVAL, ETC. WITH THE OWNER OR BUILDING MANAGER. 9. ABBREVIATIONS NOTED IN THE DRAWINGS OR SPECIFICATIONS ARE THOSE COMMONLY USED. THE ENGINEER WILL DEFINE ANY ABBREVIATION QUESTIONED UPON REQUEST. 10. THE CONTRACTOR SHALL PROVIDE ALL NECESSARY TEMPORARY BARRIERS, LIGHTING, COVERING, BRACING, SHORING, FIRE PREVENTION AND OTHER EQUIPMENT NECESSARY TO PROTECT THE SAFETY AND SECURITY OF ALL PERSONS AND THE PROPERTY THROUGHOUT THE ENTIRE PERIOD OF CONSTRUCTION. 11. THE CONTRACTOR SHALL REPAIR OR REPLACE ANY EXISTING FINISHES AND/OR ANY ITEMS DAMAGED DURING CONSTRUCTION TO MATCH THE ADJACENT EXISTING. 12. THE PLANS ARE NOT TO BE SCALED. THE PLANS AND DIAGRAMS SHOW RELATIVE LOCATIONS AND ACTUAL EXISTING LOCATIONS MAY VARY IN THE FIELD. 13. THE CONTRACTOR SHALL REVIEW EXISTING BUILDING SYSTEMS AND UTILITIES AS TO THEIR COMPLIANCE WITH THE FLORIDA BUILDING CODE AND OTHER APPLICABLE CODES AND NOTIFY THE ENGINEER OF ANY NON -CONFORMING ITEMS FOUND. 14. SECTIONS AND DETAILS SHOWN TYPICAL ON THE PLANS MAY NOT BE SPECIFICALLY NOTED AT EACH APPLICABLE LOCATION. HOWEVER, THESE DETAILS MAY BE APPLICABLE OR MAY BE REQUIRED IN MORE THAN ONE LOCATION. 15. THE CONTRACTOR SHALL COORDINATE HIS CONSTRUCTION SCHEDULES, PLANNED POWER OUTGOS, NIGHTTIME WORK, WEEKEND WORK AND WORK IN OTHER ADJACENT TENANT SPACES WITH THE OWNER PRIOR TO PERFORMING THE WORK. 16. THE CONTRACTOR SHALL SUPPLY THE OWNER WITH ALL EQUIPMENT MANUALS AND WARRANTIES. 17. THE CONTRACTOR SHALL GUARANTEE IN WRITING ALL MATERIALS AND LABOR FOR A PERIOD OF ONE YEAR FROM THE DATE OF FINAL ACCEPTANCE BY THE OWNER AND WILL AT HIS OWN COST REPAIR OR REPLACE ALL WORK OR DAMAGES CAUSED BY THE WORK WHICH BECOMES DEFECTIVE DURING THE TERM OF THE GUARANTEE. AND OTHER SPECIFIC REQUIREMENTS MAY BE MODIFIED OR EXTENDED BY THE OWNER/CONTRACTOR AGREEMENT. 18. WHERE DISSIMILAR METALS COME IN CONTACT, THE CONTRACTOR SHALL PROVIDE PROPER INSULATION TO PREVENT GALVANIC OR ELECTROLYTIC ACTION AS WELL AS VIBRATION OR NOISE TRANSMISSION. 19. THE CONTRACTOR SHALL PROVIDE THE OWNER WITH A SET OF AS BUILT DRAWINGS INDICATING ALL FILED CHANGES, ADDITIONS OR DELETIONS MADE DURING CONSTRUCTION. 20. ALL DEMOLITION SHALL BE COORDINATED WITH THE OWNER PRIOR TO PERFORMING THE WORK. 21. ALL NEW MATERIALS/EQUIPMENT SHALL HAVE U.L. (UNDERWRITER'S LABORATORY) APPROVED LABELS AS ACCEPTED BY LOCAL AUTHORITY. 22. ELECTRICAL CONTRACTOR SHALL COORDINATE ALL HIS WORK WITH THE UTILITY COMPANIES TO ASSURE THAT IT COMPLIES WITH THEIR REQUIREMENTS. 23. ALL WORK PERFORMED UNDER THIS CONTRACT SHALL COMPLY WITH ALL NATIONAL, STATE, AND LOCAL CODES HAVING JURISDICTION AND WITH ALL REQUIREMENTS OF THE UTILITY COMPANIES WHOSE SERVICES SHALL BE USED. 24. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS AND SHALL NOTIFY THE ENGINEER IF ANY DISCREPANCIES ARE DISCOVERED OR DEVIATIONS FROM THE APPROVED PLANS REQUIRED BEFORE PROCEEDING WITH THE WORK INVOLVED. COMMENCEMENT OF THE WORK SHALL CONSTITUTE ACCEPTANCE OF EXISTING CONDITIONS. 25. IF DOUBT EXISTS IN THE MIND OF THE BIDDER AS TO THE TRUE MEANING OF ANY PART OF THESE CONSTRUCTION DRAWINGS, BIDDER MUST REQUEST THE INFORMATION IN WRITING FROM THE ENGINEER IMMEDIATELY. 26. ALL SHOP DRAWINGS SHALL BE SUBMITTED W/ CONTRACTOR'S REVIEW STAMP TO THE ENGINEER FOR APPROVAL PRIOR TO FABRICATION. ALLOW 10 BUSINESS DAYS FOR REVIEW. 27. ANY SUBSTITUTIONS MUST BE REVIEWED AND APPROVED IN WRITTING BY THE ENGINEER PRIOR TO FABRICATION OR PURCHASING. 28. ALL WOOD IN CONTACT WITH MASONRY, CONCRETE, OR EXPOSED TO WEATHER SHALL BE PRESSURE TREATED. 29. ALL MATERIALS SHALL HAVE A MINIMUM CLASS "C" FLAME SPREAD RATING. 30. PROVIDE ONE TYPE ABC RATED FIRE EXTINGUISHER PER EVERY 3000 SQUARE FT OR FRACTION THEREOF OF BUILDING AREA. (PROVIDE 2 MIN.) 31. ALL NEW WALLS SHALL RECEIVE ONE COAT OF PRIMER PRIOR TO RECEIVING TWO COATS OF INTERIOR LATEX PAINT. COLOR AS SELECTED BY OWNER. 32. CONTRACTOR SHALL COORDINATE ALL NEW CABINETRY, MILLWORK, EQUIPMENT, AND FINISHES WITH OWNER. 33. ALL NEW DRYWALL SHALL BE SMOOTH FINISH UNLESS OTHERWISE NOTED. 34. ALL DOOR AND WINDOW FRAMES SHALL BE CAULKED AROUND ENTIRE PERIMETER. 35. PROVIDE 2 X 4 BLOCKING AT PERIMETER OF ALL DOOR AND WINDOW OPENINGS. 36. IT IS NOT WARRANTED THAT THE EXISTING CONDITIONS SHOWN ARE REPRESENTATIVE OF ACTUAL EXISTING CONDITIONS. ENGINEER ASSUMES NO RESPONSIBILITY FOR EXISTING CONDITIONS WHICH ARE SHOWN ONLY FOR REFERENCE. CONTRACTOR TO VERIFY ALL CONDITIONS, MEASUREMENTS, & ELEVATIONS BEFORE START OF CONSTRUCTION OR FABRICATION. INFORM ENGINEER IN WRITING OF ANY DISCREPANCIES. EGRESS FLOOR LEVEL NOTES: 1. LEVEL CHANGE AT DOORS SHALL NOT EXCEED 1/2" PER 11-4.13 F.B.C. 2. DIFFERENCE IN FLOOR LEVEL BETWEEN OPPOSITE SIDES OF EGRESS DOORS SHALL NOT EXCEED 1/2". (N.F.P.A. 101 - 7.2.1.3) ACCESSIBILITY NOTES THE DESIGN OF SPACES DEPICTED IN THESE DRAWINGS COMPLIES WITH THE ACCESSIBILITY REQUIREMENTS OF THE FLORIDA BUILDING CODE 2017 (6th EDITION). BUILDING SHALL INCLUDE AN ACCESSIBLE ROUTE FOR THE PUBLIC FROM ACCESSIBLE PARKING SPACES TO ENTRY DOORS & INTO THE BUILDING. ALL PUBLIC AREAS ARE ACCESSIBLE & HAVE NO LEVEL CHANGES GREATER THAN J" EXCEPT AS PROVIDED BY RAMP. SLAB NOTES 1 • REPAIR SLAB -ON -GRADE WITH 4" THICK (3000 PSI) P.I.P CONCRETE EXCEPT WHERE NOTED. REINFORCE W/ 6x6 - W1.4xW1.4 W.W.F. (PROVIDED IN SHEETS) OVER 10 MIL . VAPOR RETARDER (LAP 6" AND TAPE SEAMS) OVER WELL COMPACTED TREATED SOIL. 2. CJ= PROVIDE SLAB CONTROL JOINTS AT 8'-0" MAX. EXISTING TENANT WALL FINISH. F.V. EXISTING 8" MASONRY WALL [:1 E F-1 F-1 Du NEW lh" GYPSUM WALLBOARD ON 1X2 P.T. FURRING STRIPS ON R5 L-FOIL (CONT.) BOARD. PROVIDE 1 x 2 P.T. FIRE STOPS ® WALL MIDHT. NOT TO EXCEED 8'-0" HORIZ. OR VERTICALLY. WALL TYPE 'A' EXISTING TENANT WALL FINISH. F.V. EXISTING 8" MASONRY WALL-\ L [EXISTING MASONRY. PROVIDE FLUSH FINISH JOINT WHERE REQUIRED BY TENANT. PAIN AND COLOR PER TENANT REQUIREMENTS. -L WALL TYPE ID' #10 WIRE 2 16' O.C. MAX, WITH (8) TWISTS MIN. \ / DIAG❑NAL BRACES 2 O.C. MAX. TO ROOF STRUCT, \� / TO ROOF STRUCT. �n SEE REFLECTED -� CEILING PLANS 0 NOTES: 1. ALL MATERIALS SHALL HAVE A MINIMUM CLASS "C" FLAME SPREAD RATING. 2. PROVIDE ONE TYPE ABC RATED FIRE EXTINGUISHER PER EVERY 3000 S.F. OR FRACTION THEREOF OF BUILDING AREA. (PROVIDE 2 MIN.) 3. ALL NEW WALLS SHALL RECEIVE ONE COAT OF PRIMER PRIOR TO RECEIVING TWO COATS OF INTERIOR LATEX PAINT. COLOR AS SELECTED BY OWNER. 4. CONTRACTOR SHALL COORDINATE ALL NEW CABINETRY, MILLWORK, EQUIPMENT AND FINISHES WITH OWNER. 5. ALL NEW DRYWALL SHALL BE SMOOTH FINISH UNLESS OTHERWISE NOTED. MINIMUM INTERIOR FINISH CLASSIFICATION OCCUPANCY UNSPRINKLERED EXIT OTHER SPACES EXITS CORRIDORS GROUP M, MERCANTILE A A C ODOOR NUMBER o-WINDOW TYPE ECTION NAME WALL TYPE # SECTION APPEARS WALL TYPE ON SHEET # DESIGNATION SECTION DESIGNATION IMPORTANT NOTE TO ELECTRICAL & PLUMBING CONTRACTORS: ALL PLUMBING PIPING ELECTRICAL CONDUITS SWITCHES & OUTLETS SHALL BE MADE OF NON- COMBUSTIBLE MATERIALS & SEALED TIGHT OR BE RUN IN A SECONDARY FRAME WALL ADJACENT TO FIRE WALL. WALL METAL STUDS PER PLANS. CONTRACTOR NOTE: CONT. BLOCKING AT ALL DIMENSIONS ARE TO THE APPROXIMATE INCH. IF MIDHEIGHT THERE IS A MAJOR DISCREPANCY REGARDING A DIMENSION PLEASE CONTACT THE OWNER OR ENGINEER. ALL INTERIOR CABINETS , PLUMBING FIXTURES, LIGHT 1 ITERIOR PARTITION FIXTURES ETC. TO BE DETERMINED BY OWNER BRACE COORDINATE ALL RADIUSED CORNERS WITH OWNER. 3 1 /2" (20GA) MTL GYP. BD. STUDS ® 24" O/C MAX. INTERIOR WALL WALL TYPE 'B' 6", -20GA. STUDS J ® 24" O/C MAX. NEW 1 /2" GYPSUM BOARD PLUMBING WALL PLUMBING WALL TYPE 'C' EXTERIOR EXISTING STUCCO FINISH EXISTING 8" MASONRY WALL NEW %" GYPSUM WALLBOARD ON 1 X2 P.T. FURRING STRIPS ON R5 L-FOIL (CONT.) BOARD. PROVIDE 1 x 2 P.T. FIRE STOPS ® WALL MIDHT. NOT TO EXCEED 8'-0" HORIZ. OR VERTICALLY. WALL TYPE 'F"__/_� p WALL LEGEND TYPE SECTION DESCRIPTION FIRE RATING REMARKS 0 EXISTING 8" REINFORCED MASONRY WALL 1-HR 101 1 11111■ B NEW NON BEARING PARTITION (3 1/2" 24GA 0 16" O.C.) TO 6" ABOVE CEILING NA © NEW NON BEARING PLUMBING WALL (6" 20GA ® 16" O.C.) TO 6" ABOVE CEILING NA ALL DIMENSIONS & ELEVATIONS ARE EXISTING TO BE VERIFIED IN FIELD ROOM FINISH SCHEDULE (COORDINATE AND CONFIRM WITH TENANT) ROOM NAME FLOOR BASE WALLS CEILING REMARKS NUMBER NUMBERI NAME NORTH SOUTH EAST WEST 101 RETAIL -AREA TILE-T1 BASE -B1 PAINTED GYP. BD PAINTED GYP. BO � ► WATERPROOF PAINT ON PAINTED GYP. BD EXPOSED FOAM ((BLACK CDDRaNATE COLORS AND DUCT 101 BOARDINSULATION ON M tL. DE�K MODELS WITH OWNER 102 BACK ROOM TILE-Tl BASE -B1 PAINTED GYP. BD (LATE( EPDXY WATERPROOF PAINTED GYP. BD PAINTED GYP. BD PAINTED GYP. BD EXPOSED FOAM ((BLACK) COORDINATE COLORS AND DUCT 102 PAINT AT WET AREA INSULATION ON M1L. DECK MODELS WITH OWNER 103 RESTROOM TILE-T1 BASE -B2 LATE EPDXY WATERPROOF PAINT ON GYP. LATEX EPDXY WATERPROOF PAINT ON GREEN LATEX EPDXY WATERPROOF PAINT ON LATE( EPDXY WATERPROOF PAINT ON PAINTED GYP. BD (8'-0) COORDINATE COLORS AND DUCT 103 BOARD GYP. BOARD GYP. BOARD GYP. BOARD MODELS WITH OWNER ROOM FINISH LEGEND ACT-1 ARMSTRONG, SQUAR EDGE 2048 ACT-2 ARMSTRONG. FIRE RATED SQUAR EDGE 2048 B-1 r MOOD BASE PAINTED B-2 8' CERAMIC BASE T-1 12X12 CERAMIC TILE NEW 3-5/8" - METAL STUDS FURRING ® 16" O.C. FOR THE WATER FOUNTAIN PLUMBING ADJACENT TENANT SPACE PIZZA HUT RESTAURANT EXISTING 2-HR 8" MASONRY WALLS. EXISTING 8" MASONRY WALLS. 17'- 3" EXIST. 3'4"X6'8" METAL DOOR. EXIST. °D METER x 3 ■ ml 1 101■ ■ .7'-6J2" 3'-.4" 6' 4" �F 117'_2,Y2"-. 0 EXIST. ELECT. PANEL 0 102 CID 00 I. . 5,_O L 1 7'-6„ 4'-2" 2" 1( H.S 10 FX ' U a ISEX EXIST. =_ 3" VTR -I- " .I . �QO so.l �03 .3 0 X6 8t Ea Bo FF=O-0D 101- TR. EXIST: 4" SLAB ON GRADE SEE FINISH SCHEDULE -- & COORDINATE ALL FINISHES .WITH _TENANT. 'TYP. EXISTING CONC. STEPS TO BE REPLACED BY PRE-ENGINEERED METAL STEPS WITH LANDING AND RAILING BY OTHERS UNDER SEPARATE PERMIT. 00 Lo ADJACENT TENANT SPACE: EXIST. PET SUPPLY RETAIL EXISTING 2-HR 8" MASONRY WALLS F.. O'o 1 x EXISTING o STOREFRONT ro 9'-8" 3'-0" 46y2„ 18'-7" EXISTING SIDEWALK UNDER EXISTING CANOPY TO REMAIN KEVIL`JV DATE;IdIOIJJU JN{Q _. � � SllIH2�AHc'.�- �` • CITY OF ZFPHYRH LL 17UILDINu OFFICIAL--- --� - ,RTH PORPOSED FLOOR PLAN SCALE: 1 /4" = 1'-O" BEFORE PERMITTING OR START OF CONSTRUCTION: 1. TENANT TO ACQUIRE LANDLORD WRITTEN APPROVAL OF ALL PROPOSED ALTERATIONS 2. CONTRACTOR TO VERIFY ALL EXISTING DIMENSIONS AND ELEVATIONS. 3. CONTRACTOR TO COORDINATE ROUGH WINDOW/ DOOR OPENINGS SIZE W/ MFR SPEC ISSUED FOR: REVIEW 11.01.2021 1�11� ww>_w_ozw E- �D "t O Lo Q � � w Z Q J 0 W 0 0 Z a0 W N LL. 0 W 0 W O > O n' in W O z z O F U o Lo Q c) U z w w F- O O w w w x a a rn t` O CO U � v� In F--� co I L%_CQ o V1 H® O W z W �J w � co co a H Qj ti ti a� F a 0 Ey � a m w 0 ai wOf < a o wCQ a co JOB. N0.21040 �y COA. NO.291lE MAZEN MARIE, PE. (F . PE 60166) w cn i��; ca ui z • . ". r� �, .�. �•. ,.� ;0 z w FR'.7F'• �.a G1.1 L- I ISSUED FOR: REVIEW 11.12.2021 EXISTING (EXPOSED) METAL ROOF JOIST TO REMAIN. APPLY R36 SPRAY FOAM INSULATION WITH THERMAL BARRIER TO ENTIRE BOTTOM OF DECK IN THE SPACE. (ICYNENE ULTRA SELECT DC-315 OR APPROVED EQUIV.) NEW 2'X4' LIGHT FIXTURE 15'-4" EXPOSED NEW A.0 DUCT16 T DECK CLG. SYSTEM. SEE (W/ SPRAY INSULATION MECHANICAL - DRAWINGS T la 1 1 T 15'-4" EXPOSED DECK CLG. (W/ SPRAY INSULATION) EXISTING SIDEWALK UNDER EXISTING CANOPY TO REMAIN PROPOSED REFLECTED CEILING PLAN SCALE: 1 /4" = 1'-0" WALL -HUNG FIRE EXTINGUISHER WALL FLOOR INSTALLATION NOTES: 1. PORTABLE FIRE EXTINGUISHERS SHALL MEET REQUIREDMENTS OF NFPA 10, LATEST EDITION. 2. TOP OF FIRE EXTINGUISHER (OR CABINET) SHALL NOT EXCEED 5'-0" A.F.F. 3. BOTTOM OF FIRE EXTINGUISHER (OR CABINET) SHALL NOT BE LOWER THAN 4" A.F.F. 4. FINAL LOCATIONS OF FIRE EXTINGUISHERS TO BE DETERMINED BY FIRE MARSHAL. 5. FIRE EXTINGUISHERS SHALL BE PLACED NEXT TO EACH EXTERIOR EGRESS DOOR. 6. FIRE EXTINGUISHERS SHALL BE LOCATED SO THAT THE MAXIMUM TRAVEL DISTANCE FROM ANY INTERIOR POINT OF THE ENTIRE SPACE SHALL NOT EXCEED 75'. 7. ATTACHMENT TO WALLS PER MANUFACTURER SPECIFICATIONS. WALL HUNG FIRE EXTINGWISHER LIFE SAFETY REQUIREMENTS N.F.P.A. 101, 2018 EDITION TABLE A.7.6 COMMON PATH, DEAD-END, AND TRAVEL DISTANCE LIMITS TYPE OF COMMON PATH LIMIT DEAD-END LIMIT TRAVEL DISTANCE LIMIT UNSPRINKLERED SPRINKLERED UNSPRINKLERED SPRINKLERED OCCUPANCY UNSPRINKLERED SPRINKLERED m (ft.) m (ft.) m (ft.) m (ft.) m (ft.) m (ft.) MERCANTILE EXIST. 23 (75) 30 (100) 6.1 (20) 15 (50) 60 (200) 91 (300) FLORIDA BUILDING CODE - 2020 (7TH EDITION) TABLE 1016.1 - EXIT ACCESS TRAVEL DISTANCE OCCUPANCY WITHOUT SPRIKLER WITH SPRIKLER SYSTEM SYSTEM (feet) (feet) M 150 250 LIFE SAFETY LEGEND NOTE: I FOR TRAVEL -----'-'-TRAVEL DISTANCE LAYOUT DISTANCES PROVIDED, SEE FLOOR PLAN. MINIMUM INTERIOR FINISH CLASSIFICATION OCCUPANCY UNSPRINKLERED EXIT OTHER SPACES EXITS CORRIDORS GROUP M, MERCANTILE A A C ACCESSIBILITY NOTES THE DESIGN OF SPACES DEPICTED IN THESE DRAWINGS COMPLIES WITH THE ACCESSIBILITY REQUIREMENTS OF THE FLORIDA BUILDING CODE 2017 (6th EDITION). BUILDING SHALL INCLUDE AN ACCESSIBLE ROUTE FOR THE PUBLIC FROM ACCESSIBLE PARKING SPACES TO ENTRY DOORS & INTO THE BUILDING. ALL PUBLIC AREAS ARE ACCESSIBLE & HAVE NO LEVEL CHANGES GREATER THAN j" EXCEPT AS PROVIDED BY RAMP. PLAN LEGEND CLASS A: PROVIDE ONE WALL HUNG FIRE EXTINGUISHER AS PER NFPA 101 FOR EACH 3,000 SQ.FT. OF BUILDING WITH A 75'-0" MAX. TRAVEL DISTANCE. REFER TO NFPA 10 SECTION 1-6.10 FOR FIRE EXTINGUISHER MOUNTING HEIGHTS. B FEX - WALL MOUNTED, CLASS B. FIRE EXTINGUISHER EXIST EXIT SIGN WITH BATTERY PACK. SEE ELEC. DWGS. An EMERGENCY LIGHT FIXTURE WITH BATTERY PACK SEE ELECTRICAL DWGS. �1 SECURITY CAMERA STOREFRONT SIGN WHICH READS: "CASH REGISTER CONTAINS $50 OR LESS AT ALL TIMES". MO SECURITY HEIGHT MEASURE INSTALLED ® EXITS • ALARM PANIC BUTTON UNDER COUNTER. CEILING PLAN LEGEND 2'X4' SUSPENDED CEILING PANEL. SEE NOTES. 1 /2" DRYWALL CEILING ON 2X FRAMING PER PLAN. ®DENOTES 2'x4' PARABOLIC LIGHT FIXTURES. SEE ELECTRICAL DRAWINGS FOR SPECS. ® DENOTES 2'x2' PARABOLIC LIGHT FIXTURES. SEE ELECTRICAL DRAWINGS FOR SPECS. DENOTES LIGHT FIXTURE SEE ELECTRICAL DRAWINGS FOR SPECS. ExIST EXIT SIGN WITH BATTERY PACK SEE ELECTRICAL DWGS. EMERGENCY LIGHT FIXTURE WITH BATTERY PACK. SEE ELECTRICAL DWGS. ® CEILING MOUNTED AIR SUPPLY DIFFUSER SEE MECHANICAL DWGS. Z RETURN AIR SEE MECHANICAL DWGS. CEILING MOUNTED EXHAUST FAN SEE MECHANICAL DWGS. EGRESS FLOOR LEVEL NOTES: 1. LEVEL CHANGE AT ALL DOORS SHALL NOT EXCEDEED 1/2" AS PER 11-4.13 F.B.C. 2. DIFERENCE IN FLOOR LEVEL BETWEEN OPPOSITE SIDES OF EGRESS DOORS SHALL NOT EXCEED 1 2". N.F.P.A. 101 - 7.2.1.3 DRAWING NOTES 1. REFER TO CIVIL PLAN FOR EXISTING FIRE HYDRANT LOCATIONS. 2. REFER TO MECHANICAL AND ELECTRICAL DRAWINGS FOR FURTHER INFORMATION. 3. PROVIDE MAXIMUM OCCUPANCY SIGN FLAME SPREAD NOTE: ALL INTERIOR FINISHES INCLUDING WALLS, PARTITIONS, CEILINGS AND OTHER EXPOSED INTERIOR SURFACES, COMPRISING BOTH PLASTER, WOOD OR OTHER INTERIOR FINISH MATERIAL AND ANY SURFACING MATERIAL SUCH AS PAINT OR WALL PAPER APPLIED THEREOF SHALL HAVE A FLAME SPREAD CLASSIFICATION OF CLASS C U.N.O. SUSPENDED CEILING GENERAL NOTES 1. METAL SUSPENSION SYSTEMS FOR ACOUSTICAL TILE AND FOR LAY -IN PANEL CEILINGS SHALL BE INSTALLED IN ACCORDANCE WITH FLORIDA BUILDING CODE. 2. HANGERS FOR SUSPENDED CEILINGS SHALL BE FASTENED TO OR EMBEDDED IN THE STRUCTURAL FRAMING MASONRY OR CONCRETE. HANGERS SHALL BE SADDLE -TIED AROUND MAIN RUNNERS TO DEVELOP THE FULL STRENGTH OF THE HANGERS. LOWER ENDS OF FLAT HANGERS SHALL BE BOLTED WITH 3/4 INCH BOLTS TO RUNNER CHANNELS OR BENT TIGHTLY AROUND RUNNERS & BOLTED TO THE MAIN PART OF THE HANGER. 3. SPLICES AND INTERSECTIONS OF RUNNERS SHALL BE ATTACHED W/ MECHANICAL INTERLOCKING CONNECTORS SUCH AS POP RIVETS, SCREWS, PINS, PLATES WITH BENT TABS, OR OTHER APPROVED CONNECTORS. DESIGN CONNECTORS FOR 2 X DESIGN LOAD OR ULTIMATE AXIAL TENSION OR COMPRESSION (MINIMUM 60 POUNDS). OR, CROSS -FURRING SHALL BE SECURELY ATTACHED TO THE MAIN RUNNER BY SADDLE -TYING W/ NOT LESS THAN ONE STRAND OF NO. 16 OR TWO STRANDS OF NO. 18 U.S. GAUGE 11E WIRE OR APPROVED EQUIVALENT ATTACHMENTS. 4. RUNNERS AND FURRING. THE MAIN RUNNER AND CROSS -FURRING SHALL BE IN STANDARD SIZES AS PROVIDED BY MANUF., EXCEPT THAT OTHER STEEL SECTIONS OF EQUIVALENT STRENGTH MAY BE SUBSTITUTED. 5. LATERAL SUPPORT MAY BE PROVIDED BY FOUR WIRES OF MINIMUM NO. 12 GAUGE SPLAYED IN FOUR DIRECTIONS 90 DEGREE APART, AND CONNECTED TO THE MAIN RUNNER WITHIN 2" OF THE CROSS RUNNER AND TO THE STRUCTURE ABOVE AT AN ANGLE NOT EXCEEDING 45 DEGREE FROM THE PLANE OF THE CEILING. THESE LATERAL SUPPORT POINTS SHALL BE PLACED 12' O.C. IN EACH DIRECTION WITH THE FIRST POINT WITHIN 4' FROM EACH WALL. 6. ALLOWANCE SHALL BE MADE FOR LATERAL MOVEMENT OF THE SYSTEM. MAIN RUNNERS AND CROSS RUNNERS MAY BE ATTACHED AT TWO ADJACENT WALLS WITH CLEARANCE BETWEEN THE WALL AND THE RUNNERS MAINTAINED AT THE OTHER TWO WALLS. 7. VERTICAL SUPPORT SHALL BE PROVIDED AS REQUIRED WITH ADDED REQUIREMENT THAT DISCONTINUOUS ENDS OF CROSS RUNNERS AND MAIN RUNNERS BE VERTICALLY SUPPORTED WITHIN 8" OF SUCH DISCONTINUITIES AS MAY OCCUR WHERE THE CEILING IS DISRUPTED BY A WALL. 8. LIGHTING FIXTURES & AIR DIFFUSERS SHALL BE SUPPORTED DIRECTLY BY WIRES FROM STRUCTURE ABOVE. MATERIAL SPECIFICATIONS: 1. CEILING TILE SIZE: 24"X 48"X 5/8" THICK. ALL CEILING TILES IN STORE TO BE: ARMSTRONG VINYL ROCK WASHABLE CEILING PANELS (PER LOCAL COUNTY HEALTH DEPARMENT). 2. WIRES: HANGER WIRE ALLOWABLE TENSION #12 170 LB. #11 225 LB. #10 250 LB. LIFE SAFETY PLAN SCALE: 1 /4" = 1'-0" EXISTING CONC. STEPS TO BE PrDI erDn UATu rnnC :ERED 'VG ww>-to-ozw O ICJ Q co 1-4 co (m G� O ,4 Ewe x O W x N W > O m U w � z L;j Z > O F cai OJ Lo Lo Q U U Z O O W a a cn BEFORE PERMITTING OR START OF CONSTRUCTION: 1. TENANT TO ACQUIRE LANDLORD WRITTEN APPROVAL OF ALL PROPOSED ALTERATIONS. 2. CONTRACTOR TO VERIFY ALL EXISTING DIMENSIONS AND ELEVATIONS. 3. CONTRACTOR TO COORDINATE ROUGH WINDOW/ DOOR OPENINGS SIZE W/ MFR SPEC: GCE r m a Q O Z :. cm co in a w ai U h a� a EH ai d a m w w a o a CQ w d m 10B. NO.210i COA. NO.291: MAZENIMARIE, PE. (FL. PM # OXt66) 4 G1.2 L F DOOR TYPES AND CLEARNACES - ADA SECTION 404 r.......... I 18 Inin r p 446 E 9 I (a) ilront approach, pul side r------------ --- , I � ! t ! 1 c 42 rrdn 4'--� -- all - hinge (e� approach. lxA side ! 1 ! ! 24 nl ego - - - - ! kAch appinch, puM side, door provided with closer ISO (8) e�IQVBbOn front approach, push side r----------� 1 I 22 min I r 1 Soo I L------ ---� --------i 1 V 1 I 1 2 Min � sos 1 1 ------------� (c) front approach, push side, door provided with both closer and latch E� ! 22min ! Soo ! L------ r-------------- I I I I4> I I I i 1 C I � 36 min i i 8lb� 1 I 1 1 (d) hinge approach, pull side <* 1 24 rr 1 610 I 1 ! r 9'x6' ADA UNISEX RESTROOM SIGN WITH BRAILLE SIGN PER FBC ACCESSIBILITY 2020 SECT. 216 & 703 NEW UNISEX RESTROOMS DOOR ELEVATION SCALE: N.T.S. GRAPHICS - ADA SECTION 703 C ■ I ^ " X 48" SINK � CLEARANCE I ■ 48" cal I � ■ C co ■ I-- - - - - - - - - 54" X 60" DOOR 54 ■ CLEARANCE 703A.1 Height Above Finish Floor or Ground. Tactile characters on signs shall be located 48 inches (1220 mm) minimum above the finish floor or ground surface, measured from the baseline of the lost tact le character and 60 inches (1525 mm) maximum above the finish floor or ground surface, measured from the baseline of the highest tactile character. 703A.2 Location. Where a tactile sign is provided at a door, the sign shall be bated alongside the door at the latch side. Where a tactile sign is provided at double doors with one active leaf, the sign shall be located on the inactive leaf. Where a tactile sign is provided at double doors with two active leafs, the sign shall be located to the right of the right hand door. Where there is no wall space at the latch side of a single door or at the right side of double doors, signs shall be located on the nearest adjacent wall. Signs containing tactile characters shall be located so that a clear floor space of 18 inches (455 mm) minimum by 18 inches (455 mm) minimum, centered on the tactile characters, is provided beyond the arc of any door swing between the closed position and 45 degree open position. 703.5.1 [Visual Characters] Finish and Contrast. Characters and their L - J background shall have a non -glee finish. Characters shall contrast with 308.2 Forward Reach. centered on their background with either light characters on a dark background or tcgle dark characters on a fight background. 308.2.1 Unobstructed. Where a forward reach is unobstructed, F------ -- .- 703.6.1 Pictogram Field. Pictograms shall have a field height of 6 e the high forward reach shall be 48 inches (1220 mm) maximum 1$ min " � inches (150 mm) minimum. Characters and braille shall not be located in p g and the low forward reach shall be 15 inches (380 mm) minimum as the p iccttogram fell cs " above the finish floor or ground. 9 met l � 70<i.6.2 [Pictogram] Finish and Contrast. Pictograms and their field 308.2.2 Obstructed High Reach. Where a high forward reach is Figure 703.4.2 230 L _ _ _ _ _ _ _ shall have anon -glare finish. Pictograms shall contrast with their field over an obstruction, the dear floor space shall extend beneath Location of Tactile Signs at Doors not in with either a lot pictogram on a dark field or dark pictogram on a light the element for a distance not less than the required reach depth M E pickWain field. 25 ffm over the obstruction. The high brward reach shall be 48 inches . 1�d field. 3 Teri Descriptors. Picto ems shall have text descriptions Bsa (1220 mm) maximum where the reach depth is 20 inches (514 located directly below the pictogram field. Text desaipiors shall comply �) 2ea �a) (b) mm) maximum. Where the reach depth exceeds ZQ inches (510 with 703.2, 703.3 end 703.4. mm), the high forward reach shall be 44 inches (1120 mm) Figure 703.61 7031.2.1 International Symbol of Accessibility. The International planes PIS maximum and the reach depth shall be 25 inches (635 mm) Picto ram Field Figure 306.2 Figure 306.3 Toe: Clearance Knee Clearance (h) latch approach, pull side M hwW aWoach,pish ell door 404.2.3 Clear Width. Door openings shall provide a clear width of 32 inc has (815 hinge approach, push slde Wvvided wrtl� both cbseir and hitch ml minimum. Clear openings of doorways with swinging doors shall be F. _ _ _ _ _ - - - - _ r---------- measured between the face of the door and the stop, with the door open 90 4> degrees. Openings more than 24 inches (610 mm) deep shall provide a dear I c opening of 36 inches (915 mm) minimum. There shall be no projections into the 1 24 min ! 1 24 rrt�rh 1 E required dear opening width lower than 34 inches (865 mm) above the finish floor V ' I �o i $ or ground. Projections into the clear opening width between 34 inches (89 mm) I ------ I and 80 inches (2030 mm) above the finish floor or ground shall not exceed 4 ------ inches (100 mal 404.2.4 Maneuvering Clearances. Minimum maneuvering clearances at doors and gates shall comply with 404.2.4. Maneuvering clearances shall extend the full width of the doorway and the required latch side or hinge side clearance. 404.2.5 Thresholds. Thresholds, if provided at doorways, shall be % inch (13 (k) mm) high maximum. Raised thresholds and changes in level at doorways shall il) latch . Pv comply with 302 and 303. la" , t side door p with qp� 404.2.E Doors in Series and Gates in Series. The distance between two hinged or pivoted doors in series and gales in series shall be 48 inches (1220 mm) Figure 404.2.4.1 minimum plus the width of doors or gates swinging into the space. Maneuvering Clearances at Manual Swinging Doors and Gates 404.2.7 Door and Gate Hardware. Handles, pull, latches, locks, and other operable parts an doors and gates shall comply with 309.4.Operedle parts of such hardware shall be 34 inches (865 mm) minimum and 48 inches (1220 mm) maximum above the finish floor or ground. Where sliding doors are in the fully open position, operating hardware shall be exposed and usable from both sides. REFER TO ADA STANDARDS FOR MORE INFORIl9ATI0N. CLEARANCE AND REACH - ADA SECTION 308 a ml 2W r--------� 1 1 c_ A. E 1 1 I eM n, I L- - - - - -- tV 17-25 430-M 11 min Figure 3082.1 Unobstructed Forward Reach 5" MIN 5" MAX coNrRas -NE;; ON FRONT oR siDE {a) (b) Figure 308.2.2 Obstructed High Forward Reach R Figure 703.4.1 Height of Tactile Characters Above Finish Floor or Ground t 1 1$ rrrt - C I , l � g Symbol of Accessibility shall comply with Figure 703.7.2.1. maximum. 308.3 Side Reach. 703.7.1 [Symbols of Accessibility] Finish and Contrast. Symbol of 308.3.1 Unobstructed. Where a clear floor or ground space accessibility and their background shall have a rum -glare finish. Symbols allows a parallel approach to an element end dire side reach is of accessibility shall contrast with their background with either a light Figure 703.7.2.1 symbol on a dark background or a dark symbol on a light background. unobstructed, the high side reach shall be 48 inches (1220 mm) maximum and the low side reach shall be 15 inches (380 mm) International Symbol REFER TO ADA STANDARDS FOR MORE /NFORMATiOIV minimum above the finish floor or ground. of Accessibility 308.3.2 obstructed High Reach. Where a shear floor or ground - __- - - _- -- x space allows a parallel approach to an element and the high side 'E $ cc E reach is over an obstruction, the height of the obstruction shall be CHANGES IN LEVEL - ADA SECTION 303 C* ao 34 inches (865 mm) maximum and the depth of the obstruction shall be 24 inches (610 mm) maximum. The high side reach shall; 303.2 Vertical. Changes in level of'l. inch (6.4 mm) high maximum shall be 48 inches (1220 mm) maximum for a reach depth of 10 inches �4 C1C1aX 2 2 be ppnrntted to be vertical. (2M mm) maximum. Where the reach depth exceeds 10 inches 6.4 6.4 �'" 13 303.3 Beveled. Changes in level between'/. inch (6.4 mm) high (255 mm), the high side reach shall be 46 inches (1170 mm) MR 4 minimum and % inch (13 mm) high maximum shall be beveled with a 10 max maximum for a reach depth of 24 inches (610 mm) maximum. 6 4 slope not steeper than 1:2. 2ss REFER TO ADA STANDARDS FOR MORE INFORMATION. Figure 3t.2 3�i•4 Ramps. Changes in level greater then inch (13 mm) high shall Vertical change in Level Figure 303.3 be ramped, and shall comply with 406 or 406. Figure 308.3.1 Beveled Change in Level Unobstructed Side Reach REFER TO ADA STANDARDS FOR MORE INFORMATION 48" MIN. z OR SIDE o z z LO 0 co N U HIG HI -LOW ELECTRIC WATER COOLER 8" MIN. 6" MAX. E.W.C. 11 HIGH DRINKING LOW DRINKING 1711-1911 FOUNTAIN SPOUT FOUNTAIN SPOUT CLEAR FLOOR SPACE HEIGHT DETAIL HEIGHT & KNEE AT DRINKING CLEARANCE DETAIL FOUNTAINS 5" MIN 5" MAX. CONTROLS ON FRONT - MIRROR PAPER TOWEL FINISHED / DISPENSER IRROR WALL SURFACE / WALL MTD. SOAP HOT WATE DASHED LINE DISPENSER INDICATES AND DRAIN REQUIRED 1UU, 5 INSULATED CLEARANCES AT z N C.3 MIN. LAVATO Y _> �, SINK WITH N = 2 LEVER HANDLE FAUCET V N xxCn ' ZO Q d W ch 8" CV CV M N N co co � MIN. 0 -1l 611 z aX. 15" MIN. URINAL SINK SINK & MISC. ITEMS ELEVATIO1C0t1_BDV8" rYN'490UNTING HT. FOR PAPER TOWEL DISPENSER AND WALL MTD. SOAP DISPENSER. OPP. HAND CONDITION MAY APPLY. RESTROOM FIXTURES TYPICAL HEIGHTS / CLEARANCES "BACK PROVIDE VERT. GRAB 3 3121, 24" N r FINISHED WALL SURFACE WATER CLOSET = N � r GRAB BAR/TOILET PAPER AT TOILET BAR ONLY IF REQUIRED 41"MAX. BY PERMITTING AUTHORITY. 6„ 12' z MAX 42"SIDE �° H.S 3 COMPN�H�. a O O Llo I ■ I /� I 100 �I I �\ ■ bl , �I I � o1 I� I I 14- 30" 6 0 / ■ T1 60" X 48" TOILET CLEARANCE 7' - 6" M NEW ADA RESTROOMS ENLARGED PLAN WALID 1/P' 1' ADA SECTION 305 305.2 Floor or Ground Surfaces. Floor or ground surfaces of a clear floor or ground space shall comply with 302. Changes in level are not permitted. 305.3 Size. The clear floor or ground space shall be 30 inches (760 mm) minimum by 48 inches (1220 mm) minimum. 305.4 Knee and Toe Clearance. Unless otherwise specified, clear floor or ground space shall be permitted to include knee and toe clearance complying with 306. 305.5 Position. Unless otherwise specified, clear I� . floor or ground space shall be positioned for either forward or parallel approach to an element. 305.6 Approach. One full unobstructed side of the clear floor or ground space shall adjoin an accessible route or adjoin another clear floor or ground space. REFER TO ADA STANDARDS FOR MORE INFORMATION GROUND AND FLOOR CLEARANCES - 48 min 1220 c I I 1 I 'Ea I h I c I I - _...,1. .� L_-.- I 1 I I I 48 min I ' I C0 �..____..., 1220 L___ ---_J 30 min Figure 305.3 IOU Clear Floor or Ground Space (a) (b) forward parallel Figure 306.5 Position of Clear Floor or Ground Space 3/4" FIRE RETARDANT PLYWOOD BACKING BOARD ( TYP) AT ALL GRAB BARS. 3 5/8" STEEL STUDS 2 1/2" STEEL SECURE TO STUDS WITH SELF TAPPING SCREWS STUDS 16" O.C. (3) #8 X 1- (3) #8 X 1-1/2 SHEET METAL SCREWS SHEET METAL SCREWS (TYP.) EA. SIDE (TYP.) EA. SIDE MOUNTING PLATE COVER PLATE (FIN: STAINLESS STEEL -SATIN) GRAB BARS SHALL BE INSTALLED W.R. GYPSUM BOARD PARTITION TO SUSTAIN A DEAD WEIGHT OF 250 1 /4" Y04 TOGGLE BOLTS BY IBS, INC. (TYP) POUNDS FOR 5 MINUTES, AND AS PER ALL APPLICABLE CODES. 1 1/2" O.D. STAINLESS STEEL GRAB BARS SEE ELEVATIONS FOR MOUNTING HEIGHTH. IF GRAB BARS ARE TO BE INSTALLED ON EXIST'G. WALL, G.C. IS TO REMOVE AND REPLACE GYP. BD. AS REO'D. FOR INSTALLATION GRAB BAR DETAIL OF WD. BLK'G. SCALE: none BEFORE PERMITTING OR START OF CONSTRUCTION: 1. TENANT TO ACQUIRE LANDLORD WRITTEN APPROVAL OF ALL PROPOSED ALTERATIONS. 2. CONTRACTOR TO VERIFY ALL EXISTING DIMENSIONS AND ELEVATIONS. 3. CONTRACTOR TO COORDINATE ROUGH WINDOW/ DOOR OPENINGS SIZE W/ MFR SPECS ISSUED FOR: REVIEW 11.01.2021 Z 0 iY U In LLI e�eeeme� Ww>-W-0ZW � � o Q In co a co � E-i � Q o z�11 z Z Q � co z a O x Cl) N � O O W E- O � (� W W M � w� Z z o F a o � LO �' LO 04 z W U I'_ Z 'o 'o w a d Lp� r- O � U CO o0 m I1 r` �0 1.4 Q'I �® H o W I� z W co co w Ely E, CD °' a 0 E d x I-�-I m r w ai Q d O w � t` a m JOB. NO. 21040 GCE OA. NO.29116 MAZEN ARIE, PE. (FL. # 1.66) J _ C" - w f �Q � �4% G1. 3 L 16 GA. PL W/ (3) #12 SCREWS INTO JAMB AND (3) #12 SCREWS INTO LINTEL BEAM EACH SIDE OF LINTEL BEAR LINTEL ON TOP OF VERT. STUD CONTINUOUS TOP RUNNER TRACK WELDED TO HEADER (16 GA TYP.) (2) 6" CEE STUD (16 GA.) 6" STUDS SEE DETAIL #3 LOAD BEARI NO 'HEADER NO SCALE STEEL JAMB STUDS NESTED TOGETHER SEE DETAIL 3 4"x4"x16 GA CLIP ANGLE 5" LONG. SCREW ATTACHED TO JAMB & TRACK / (6) 112 HEAD AND/OR SILL SET NO SCALE FULL HEIGHT STUD JAMB STUD SEE DETAIL 3 16 GA. RUNNER TRACK } WELD TO TRACK 4'x4'x16GA. (N.T.S.) CUP ANGLE 5" LONG, ATTACHED TO =A.CH SIDE OF JAMB 2 JAMB ANCHOR DET NO SCALE DOOR ELEVATION NO SCALE FULL HEIGHT 6" CEE STUD (18 GA.) TO BE PLACED ADJ. TO ALL JAMBS & WELD (3) 6" CEE JAMB STUD EACH SIDE OF OPENING WELD ATTACH JAMB STUDS TOGETHER 3 TYP JAMB DET NO SCALE 112 TEK SCREWS 1\7 (16 GA.) COLD -ROLLED CHANNEL (CRC) PLACE 0 4'-0" O.C. MA (2) 110 TEK 16 GA. BRIDGE CUP W I O EACH STUD ALL METAL STUD FRAMING IS TO BE DESIGNED BY A LICENSED FLORIDA P.E. SUBMIT SIGNED & SEALED CALCULATIONS & SHOP DRAWINGS. BRIDGE CUP CAPACITY DESIGNATION F1 kips M1 in. -kips BC600 6" STUD 0.680 0.720 BC800 8" STUD 0,680 0.900 LATERAL BRACT NO NO SCALE 4"x4" x 16 GA. CUP 5' LONG ATTACHED T FULL HEIGHT STUD & RUNNER TRACK RUNNER TRACK 16 GA. MIN. TYP. FULL HEIGHT STUD JAMB STUDS HEADER NOT SHOWN FOR CLARITY 4 JAMB ANCHORAGE DET NO SCALE I Ilvv LLLVA I IUIN 1 STOREFRONT EXISTING DOOR SCHEDULE MARK WIDTH HEIGHT THICKNESS H.C.S.C. DOOR DESCRIPTION MATERIAL DOOR FINISH FRAME FRAME FINISH DOOR ELEV. SILL TYP. LOCK REMARKS KEY PRIVACY PASSAGE 1 10'-10" 12'-8" 1 3/4" i — EXIST. STOREFRONT GLASS / ALUMN. EXISTING EXISTING EXISTING 1 EXIST. DR TO COMPLY W/ COUNTY APPROVAL. INCLUDING CLOSERS & PANIC HARDWARE. G.0 VERIFY. 2 3'-0' 6'-8" 1 3/4" — — NEW SWING (RESTROOM) WOOD SATIN WOOD PAINT 2 PROVIDE DOOR CLOSER AT RESTROOMS 3 3'-4" 6'-8" j 1 3/4" — — EXIST. METAL EXIST. METAL EXISTING EXIST. EXISTING 3 EXIST. DR TO COMPLY W/ COUNTY APPROVAL. INCLUDING CLOSERS & PANIC HARDWARE. G.0 VERIFY. DOOR HARDWARE SHALL BE COMMERCIAL GRADE, ADA COMPLIANT LEVER TYPE AS MANUFACTURED BY SCHLAGE OR APPROVED EQUIVALENT. DOOR HARDWARE NOTES DOOR OPERATION SHALL COMPLY WITH THE FOLLOWING REQUIREMENTS: 1008.1.2- EGRESS DOOR SHALL BE SIDE -HINGED SWINGING. 1008.1.8- EGRESS DOORS SHALL BE READILY OPENABLE FROM THE EGRESS SIDE WITHOUT USE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT. 1008.1.9- PANIC HARDWARE SHALL COMPLY WITH THE FOLLOWING: A.- THE ACTUATING PORTION OF THE RELEASING DEVICE SHALL EXTEND AT LEAST ONE-HALF OF THE DOOR LEAF WIDTH. B.- MAXIMUM UNLATCHING FORCE OF 15 POUNDS. (67 N) 11-4.13.9- HARDWARE SHALL BE LEVER TYPE, PUSH TYPE & U SHAPE HANDLES. 11-4.13.10- CLOSER TO BE ADJUSTED SO THAT FROM THE OPEN POSITION OF 70' THE DOOR WILL TAKE AT LEAST 3 SECONDS TO MOVE TO A POINT 3" FROM THE LATCH, MEASURED TO THE EDGE OF DOOR. 11.4.13.11- DOOR OPENING FORCE: A.- EXTERIOR HINGED DOOR 8.5 Ibf (37.8 N) B.- INTERIOR HINGED DOOR 5 Ibf (22.2 N) C.- SLIDING OR FOLDING 5 Ibf (22.2 N) TYP E 1 ALUM. DOOR W/ GLAZING. SEE DOOR SCHEDULE. BUG SWEEP ALUM. THRESHOLD X Q TYPE 2 DOOR DOOR SCHEDULE. THRESHOLD N MASTIC. LE TYPE. 5" TYPE 3 EGRESS FLOOR LEVEL NOTES: 1. LEVEL CHANGE AT DOORS SHALL NOT EXCEED 1/2" PER 11-4.13 F.B.C. 2. DIFFERENCE IN FLOOR LEVEL BETWEEN OPPOSITE SIDES OF EGRESS DOORS SHALL NOT EXCEED 1 /2". (N.F.P.A. 101 - 7.2.1.3) HOLLOW METAL DOOR SEE DOOR SCHEDULE. ALUM. THRESHOLD SET IN MASTIC. BUMPER TYPE. X Q ATTACH BOTH ENDS OF RUNNER TRACK TO STUD SECTION W/ #12 TEK SCREWS SING SHORT )F STUD RUNNER TRACK 16 GA. MIN. TYP. 5 TYP.RVNNER TRACK SPLICE NO SCALE CLEAR ANODIZE[ ALUM. FRAME. KI ST. TOREFRONT D00 �.ti.rr��111`1► 11N. RUNNER TRACK ...... STUD TO RUNNER TRACK W/ (2) #12 TEK SCREWS EA. SIDE TYP. s TYP. STUD ANCHORAGE OD FRA iD DOOF 3E STAI ELEVATION 2 NEW NO SCALE ELEVATION 3 EXISTING METAL FRAME METAL DOOR ISSUED FOR: REVIEW 11.01.2021 will limemmim, Ofw>—(n-0zcn E-i �D di O Lo Q � co m [z O � Q � N w > W O m � � Q W z Lo o > Lo z w U U Z w w � 0 0 w O _ a_ V) Lp� ro d' U co U I v� co CS co W Nm �o �® 0 z co co a H aj co El U N V1 Q) a U W a o m 4, Lw N ft a o % w � O_ co GCE JOB. N2 COA. NO. 29.11116 MAZEN MARIE, PE. (FL. PE # 60166) O Q �c'_d,W A�' F �z ova„ O w EET BEFORE PERMITTING OR START OF CONSTRUCTION: 1. TENANT TO ACQUIRE LANDLORD WRITTEN APPROVAL OF ALL PROPOSED ALTERATIONS. 2. CONTRACTOR TO VERIFY ALL EXISTING DIMENSIONS AND ELEVATIONS. 3. CONTRACTOR TO COORDINATE ROUGH WINDOW/ DOOR OPENINGS SIZE W/ MFR SPECS L IJ 'I■I'�■�'IIAO!I' �I')II�I■�hAYI��1�■I� 1 ISOMETRIC VIEW PLUMBING EQUIPMENT SCHEDULE s C E^c o c ; 1 s o.% Itema ° c co ., o in o M �o min HE_ Equipment o c a. 80 x° c Manufacturer Model Number REMARKS 7 1 3 COMP SNK 1/2 1/2 2 UNIVERSAL BS1512-3 WASTE FROM EACH COMPARTMENT TO BE SEPARATELY DISCHARGED INDIRECTLY TO FLOOR SW B 1 WALL MOUNTED HAND SNK 1/2 1/2 -1-1/2j WMANCE TABOO 7-PS-40 IWASIT TO BE DIRECTLY CONNECTED TO WASTE UW-PROVIDE THERMOSTATIC MW4 VALVE TO PROVIDE TEMPERED WATER BS' F. TO 110' F. GENERAL PLUMBING SPECIFICATIONS: 1. ALL WORK UNDER THIS HEADING SHALL BE PERFORMED AND ALL MATERIALS AND EQUIPMENT SHALL BE INSTALLED IN STRICT COMPLIANCE WITH ALL RATINGS, CODES AND STANDARDS OR OTHER AUTHORITIES HAVING JURISDICTION. 2• ALL LICENSES, PERMITS, INSPECTIONS AND FEES REQUIRED FOR WORK UNDER THIS HEADING SHALL BE SECURED, PERFORMED AND PAID FOR BY THIS SUBCONTRACTOR AS A PART OF HIS CONTRACT. 3. ALL MATERIALS SHALL BE NEW, FREE FROM DEFECTS, AND FULLY EQUAL TO THE QUALITY SPECIFIED. WORK SHALL BE NOTE: EQUIPMENT REQUIREMENTS PERFORMED BY SKILLED MECHANICS AND WORKMANSHIP SHALL BE FIRST CLASS IN EVERY RESPECT. CONTRACTOR SHALL HAVE A COMPETENT SUPERINTENDENT (WHO IS EXPERIENCED IN THE WORK BEING INSTALLED UNDER THIS CONTRACT) IN CHARGE OF * THE DOMESTIC WATER PIPING SYSTEM SHALL BE FLUSHED WITH CLEAN WORK AT ALL TIMES DURING CONSTRUCTION. POTABLE WATER UNTIL CONTAMINATED WATER DOES NOT APPEAR AT THE OUTLET AND SHALL BE FILLED WITH A SOLUTION CONTAINING 50 PPM OR CHLORINE AND ALLOWED TO STAND AS REQUIRED BY CODE BEFORE FLUSHING. THE SYSTEM SHALL BE FLUSHED COMPLETELY WITH CLEAR 4. ALL PIPING SHALL HAVE THE MANUFACTURER'S NAME ROLLED INTO EACH LENGTH, OR SHALL OTHERWISE BE PROMINENTLY IDENTIFIED. AFTER CUTTING, ALL PIPE SHALL BE REAMED FULL BORE, AND ALL CUTTINGS, AND FOREIGN MATERIALS SHALL BE REMOVED BEFORE INSTALLATION. ITEM EQUIPMENT PLUMBING REQUIREMENTS REMARKS CW SIZE HW SIZE WASTE SIZE VENT SIZE MANUFACTURER/ MODEL WATER UNTIL ALL RESIDUAL CHLORINE CONTENT IS REMOVED. 5. ALL SANITARY WASTE AND VENT PIPING SHALL BE PVC SCHEDULE 40, WITH FITTINGS OF THE SAME WEIGHT AS THE PIPE. UNDER CHLORINATION SHALL BE PERFORMED AFTER ALL PIPING AND FINAL CONNECTIONS AND PRESSURE TESTING HAVE BEEN COMPLETED. D.F. ADA COMPLIANT WALL HUNG BI-LEVEL DRINKING FOUNTAIN 1/2" 2" 2• SUNROC ADAACB OR APPROVED EQUAL GROUND PIPING TO HAVE 1/4" PER FOOT SLOPE. 6. ABOVE GRADE DOMESTIC WATER PIPE SHALL BE TYPE "L" SEAMLESS, HARD DRAWN COPPER TUBING AND TYPE "K" BELOW GRADE IN CONFORMANCE WITH ASTM B88-48. FITTINGS SHALL BE WROUGHT COPPER SUITABLE FOR 200 PSI. CONNECTIONS TO DISSIMILAR MATERIALS SHALL BE MADE WITH DIELECTRIC UNIONS. JOINTS SHALL BE 95-5 TIN ALTIMONY FOR 200 PSI. BELOW M.S. MOP SINK 1/2" 1/2" 3" 2• ADVANCE TABCO 9-OP-20 OR APPROVED EQUAL WASTE TO BE DIRECTLY CONNECTED TO WASTE LINE. PLUMBING EQUIPMENT NOTES: JOINTS SHALL BE BRAZED. 7. ALL FIXTURES SHALL HAVE INDIVIDUAL FIXTURE CONTROL VALVES WHICH SHALL BE CRANE, WATTS, NIBCO OR APPROVED EQUAL. VALVES OF EACH TYPE, SUCH AS GATE OR GLOBE, SHALL BE THE PRODUCTS OF ONE MANUFACTURER. VALVES SHALL BEAR THE NAME OR TRADEMARK OF THE MANUFACTURER AND THE WORKING PRESSURE CAST OR STAMPED ON THE VALVE BODY. MIN. 125 PSI. ALL VALVES SHALL BE ACCESSIBLE FOR EASE OF OPERATION. W.H. TANKLEGROUND HEATERSS ELECTRIC WATER 3,4" 3/4" TSTIEBEL EMPRA 2�223420 OR APPROVED EQUAL O CONNECT NEW PLUMBING DRAIN LINES TO EXISTING SANITARY WASTE LINE, CONTRACTOR TO VERIFY EXACT LOCATION IN FIELD. El SHOCK SUPPRESSORS AMTROL DIATROLS 537 OR APPROVED EQUAL INSTALLED AS RECOMMENDED BY P.D.I. 3 O REUSE EXISTING 3" VENT THROUGH ROOF (VTR) AND CONNECT TO VENT LINES IN CEILING SPACE, CONTRACTOR TO VERIFY EXACT 8. PROVIDE DIELECTRIC FITTINGS BETWEEN PIPING OF DISSIMILAR METALS AND AT WATER HEATER CONNECTIONS. El PREVENTER WATTS LSD-3 ASSE 1022 EXIST. SANITARY WASTE LINE A SZ r_ K 7 8 LOCATION IN FIELD. O CONNECT NEW PLUMBING WATER LINE TO EXISTING WATER SUPPLY LINE. CONTRACTOR TO VERIFY EXACT LOCATION IN FIELD. O PROVIDEBACK EIS POSSIBLE.OW PVENTER AS SHOWN OR WHEREVER BACK 9. PROVIDE 1/2" THICK FLEXIBLE UNICELLULAR FIRE RETARDANT INSULATION ON EXPOSED LAVATORY TRAP AND EXPOSED HOT AND COLD WATER SUPPLY AND ANY MISCELLANEOUS PIPING SUCH AS CONDENSATE PIPING. ALL JOINTS SHALL BE INSULATED AND SEALED WITH VAPOR BARRIER CEMENT. 10. ALL PIPING, PIPE HANGERS, CLAMPS, SUPPORTS, ETC. SHALL BE FASTENED TO JOISTS OR BEAMS. WHERE PIPING IS SUSPENDED FROM STEEL JOISTS THE CONNECTION SHALL BE MADE AT THE T P H R G ADA COMPLIANT WATER CLOSET 1. 3" 2" ZURN Z5550 OR APPROVED EQUAL VITREOUS CHINA TOILET. 1 � t3 I M.S. 1 2"V ' �0 0 1 NEW FCO H 1 D.F. K EXIST. 3" VTR M EXIST. WASTE PLAN SCALE: 1/4" = V-0" ISOMETRIC VIEW WATER PLAN SCALE: 1/4" = V-0" M.S. F❑ O W.H. F CONTRACTOR SHALL VERIFY ALL EQUIPMENT & FIXTURES SPECS & UTILITY REQUIREMENTS WITH OWNER PRIOR TO ROUGH -IN. CONTRACTOR SHALL VERIFY EXISTING PLUMBING LINES AND UTILIZE AS MUCH AS POSSIBLE. ZURNZ5310 W/Z81104—XL—P VITREOUS CHINA. PROVIDE AND O C O D OF JOIST. PIPE SUPPORTS SHALL BE SPACED MO ADA COMPLIANT RESTROOM 4"CENTERSET FAUCET INSTALL THERMOSTATIC MIXING MORE THAN 10 FEET APART. NOTHING SHALL BE ATTACHED DIRECTLY TO THE DECK, CEILING SYSTEM OR DUCT WORK ABOVE. El WALL HUNG LAVATORY & 1/2" 1/2" 2" 2" WITH 4" WRIST BLADE HANDLES VALVE TO PROVIDE TEMPERED FAUCET AND POP—UP OR APPROVED WATER (85' F. TO 110' F.) AT 11. HANGERS SHALL NOT PIERCE PIPING INSULATION VAPOR BARRIER. EQUAL ALL PUBLIC LAVATORY. 12. IT IS THE CONTRACTOR'S RESPONSIBILITY TO REPAIR ANY DAMAGE DONE TO THE FIRE PROOFED STRUCTURAL STEEL SERVING El THERMOSTATIC MIXING VALVE 1/2" 1/2" WATTSSERIES MMV—UT—M1 1/2" ADJUST TO PROVIDE TEMPERED HOT WATER (85' TO 110- F.) THE FIRST FLOOR. OR FROM PUBLIC LAVATORY(S) 13. ALL HANGERS, RODS, BEAM CLAMPS ETC. EXPOSED TO PUBLIC VIEW SHALL BE PAINTED TO MATCH ADJACENT FINISHES AND BE FAUCET(S) MANUFACTURED BY F&M, GRINNEL, OR CENTRAL FOUNDRY, 14. THE CONTRACTOR SHALL ENSURE THAT ALL SLAB PENETRATIONS WITHIN THE TENANT SPACE (AND THROUGH THE ROOF) ARE PROPERLY SEALED AND REMAIN WATERTIGHT TO PREVENT POSSIBLE WATER LEAKAGE AND/OR DAMAGE. ANY DAMAGE CAUSED El FLOOR SINK 4• 2" JOSAM 49300 & 49310 SERIES. SUPER—FLO, 6" MEDIUM DEEP BODIES FROM FAILURE TO DO SO SHALL BE A CONTRACTOR'S SOLE RISK AND EXPENSE. ALL ROOF AND SLAB PENETRATIONS MADE BY 8" SQUARE TOPS THE CONTRACTOR ARE SUBJECT TO L.L. APPROVAL AS TO LOCATION AND CONSTRUCTION DETAILS. ALL PENETRATIONS IN ROOF AND CEILING SHALL BE FIRE CAULKED. JOSAM 30000—S SERIES OR PROVIDE AND INSTALL TRAP PRIMER FLOOR DRAIN 3" 2" APPROVED EQUAL BOTTOM OUTLET WITH SUPER—FLO SQUARE NIKALOY ONLY IF REQUIRED BY LOCAL CODE. 15. PROVIDE CAST BRASS OR CHROME ESCUTCHEONS WITH SET SCREW DEEP TYPE, TO COVER SLEEVES OR OF A SIZE TO COVER STRAINER WASTE TO BE DIRECTLY CONNECTED E WASTE LINE. FITTING PROJECTIONS, PROVIDE ESCUTCHEONS FOR ALL EXPOSED PIPING THROUGH WALLS, FLOORS, AND EXPOSED CEILINGS. 16. THE CONTRACTOR SHALL CORE DRILL EXISTING FLOOR SLAB AS REQUIRED FOR INSTALLATION OF UNDERSLAB UTILITIES. CONTRACTOR MUST COORDINATE ALL INSTALLATION OF BELOW -SLAB SERVICES WITH L.L. ALL MODIFICTIONS TO THE SLAB N❑ 1/2" ZURN Z-1022 SANI—GARD. CONNECT TO CW W/VALVE, EXTEND INSTALL ONLY IF REQUIRED TRAP PRIMER TPP TO FLOOR DRAIN AS REQUIRED BY LOCAL CODE. SHALL BE REPAIRED BY APPROVED L.L. METHODS THAT MEET OR EXCEED THE ORIGINAL SLAB DESIGN INCLUDING WATERPROOFING. THE CONTRACTOR SHALL PROPERLY SLEEVE AND SEAL ALL PENETRATIONS TO COMPLY WITH L.L AND CODE C/O WALL CLEAN -OUT - ZURN, #Z-1441, SMOOTH STAINLESS STEEL ACCESS COVER, DURA-COATED CAST IRON BODY. MATCH TO PIPE SIZE. REQ.'S. 17. ALL UTILITIES NOT RE -USED SHALL BE CAPPED -OFF AND REMOVED. DISPOSAL SHALL BE PER L.L. APPROVED METHOD(S). NO FCO FLOOR CLEANOUT - ZURN NO. Z-1444, POLISHED BRONZE ACCESS COVER, DURA-COATED CAST IRON BODY. MATCH TO PIPE SIZE. UTILITIES SHALL BE ABANDONED IN PLACE. NOTE: VERIFY FINAL PLUMBING REQUIREMENTS WITH EQUIPMENT CUT SHEETS AND PLANS PRIOR TO THE START OF WORK TO AVOID ANY CONFLICTS. 18. COORDINATE ALL PENETRATIONS FLOOR, DRAINS/SINKS W/ WATERPROOFING OF SLAB. 8 7/8" x 3 5/8" x 3 DRAIN LINE 3/4" HIGH FUNNEL. IF SPECIFIED. I I I FLOOR GRATE.I I � MOUNT AIR GAP = 2 x "d" FLUSH wrrrr— FLOOR vo v vv LIFT OUf ALUMINUM b SEDIMENT BUCKET. 19! FLOOR UNION HW SUI HUB OUTLET FLOOR SINK DETAILEL SCALE: NONE CHECK VALVE :W SUPPLY PROVIDE DIELECTRIC FITTINGS AT WATER WATER HAMMER HEATER CONNECTIONS ARRESTORS REFER TO SPECIFICATIONS, SCHEDULES AND NOTES FOR MORE INFORMATION. PIPING ARRANGEMENT SHOWN IS SCHEMATIC; ADJUST AS REQUIRED TO SUIT ACTUAL CONDITIONS. VERIFY CONNECTION SIZES AND LOCATIONS WITH WATER HEATER FURNISHED. REFER TO FLOOR PLANS FOR PIPE SIXES. PROVIDE SEISMIC STRAP OR BRACING IF/AS REQUIRED BY LOCAL AUTHORITIES. PROVIDE HEAT TRAP AND AUTOMATIC VACUUM RELIEF VALVE WHEN REQUIRED BY LOCAL AUTHORITIES. WATER HEATER DETAIL SCALE: NONE MA) AS' OR CLE TEE CL DI. MA INSTALL ONLY IF REQUIRED BY LOCAL CODE FOR WALL CONST. 1/2" TRAP PRIMER SUPPLY SEE ARCH. DWGS. DOMESTIC WATER LINE CLEANOUT PLUG COUNTERSUNK SCREW TRAP PRIMER VALVE POLISHED S.S. DISTRIBUTION UNIT, FOR ACCESS COVER UP TO 4 LINES FLUSH w/ WALL WASTE LINE w/ LENGTH TO SUIT AT END OF 4NOUT _\L I I I =J MAIN WASTE LINE WALL CLEANOUT DETAIL SCALE: NONE C/O CLEANOUT AND ACCESS COVER. TOP OF COVER TO BE FLUSH W/TOP OF =LOOR LINE END E LINE 'H TO SUIT E LINE 1/0 DCIVU Lr %_LCHIVVUT OCCURS AT END OF LINE FLOOR CLEANOUT DETAIL NO SCALE FCO 1/2" TRAP PRIMER LINE SLEEVE THRU SLA TRAP PRIMER CONNECTION DETAIL SCALE: N.T.S. THERMOSTATIC MIXING VALVE REDUCERv 1/2"-3/4" HW & CW WHEN APPLICABLE: HW BRANCH FROM RECIRCULATING MAIN LOOP, KEEP SHORT AS POSSIBLE. UNIONS �1/2"-3/4" TW TO FIXTURE(S), KEEP SHORT AS POSSIBLE. NOTE: INSTALL ABOVE CEILING OR IN WALL CAVITY WITH 12"x12" ACCESS DOOR WHERE REQUIRED El THEFfi l" IOSTATIG MIXING VALVE PETAL NOT TO SCALE SYMBOL CODE -�--- COLD WATER PIPING ---------- HOT WATER PIPING - - - - - - - - - - - FILTERED WATER PIPING - - - - - - - - - - - — INDIRECT WASTE PIPING SAN. WASTE PIPING — — — — — — — - EXIST. SAN. WASTE PIPING --------- WASTE VENT PIPING SHUT OFF VALVE .1 UNION T & P RELIEF VALVE &__ VALVED WATER TAP 1 CONNECT TO EXISTING STRAINER, FLUSH w/ El 1/2" TRAF PRIMER DRAIN SU DEEP SEA FLOOR DRAIN D ETAI L SCALE: N.T.S. FLOOR FINISH AIN - 1/4"/FT. MIN. ADJUSTABLE DRAIN HEAD DRAIN BODY INSIDE CAULK PIPE 0 BEFORE PERMITTING OR START OF CONSTRUCTION: 1. TENANT TO ACQUIRE LANDLORD WRITTEN APPROVAL OF ALL PROPOSED ALTERATIONS 2. CONTRACTOR TO VERIFY ALL EXISTING DIMENSIONS AND ELEVATIONS. 3. CONTRACTOR TO COORDINATE ROUGH WINDOW/ DOOR OPENINGS SIZE W/ MFR SPEC ISSUED FOR: REVIEW 11.01.2021 z F a_ FE U N w 0 w �I 0_w>-In-OZtn C) LO Q co O I-� w z H� a, x x a Q J ON. 0 0 N Z w O (� D J W � i F:. 8 Lo __l L U V Z W 0. IL t3f Lp I` O � U coII O? Lnz H I� O r— V1 � N E O W w z THF� V w co co z a L) ns EO V1 N a O E) A~ 8 ai O l Fj IL W � a co T1 JOB. N0.21040 GC �1 COA. NO.29116 MAZEN MARIE, PE. (F . PE 0166) P-1 ISSUED FOR: REVIEW 11.01.2021 m EXIST. 3" VTR 211 I I I I I I I I I I I I I I I � I I I I I I I I I I I I I I 2" 2if " I I I I 2 �I 2" I I � I I I 8 I I I WASTE ISOMETRIC SCALE: N.T.S. 3 3/4" 3/411 . 3/4" 3/411 ` W.H. ` I I 3/4if I E � I I I I I 3/4" I 3/411 I I I 1/211 �� I I ` 1/2if 1/2 1 2 I I I I I / �� I I O \ . I ❑ I I I M.S. K g I 1/2" I 1/2° 1/2" G I H K I fl/211 1 I D. F. WATER ISOMETRIC SCALE: N.T.S. BEFORE PERMITTING OR START OF CONSTRUCTION: 1. TENANT TO ACQUIRE LANDLORD WRITTEN APPROVAL OF ALL PROPOSED ALTERATIONS. 2. CONTRACTOR TO VERIFY ALL EXISTING DIMENSIONS AND ELEVATIONS. 3. CONTRACTOR TO COORDINATE ROUGH WINDOW/ DOOR OPENINGS SIZE W/ MFR SPEC: z O F a U N W a O z ww>-w-ozw o Q co CD � � H O � W wto z Ix Q. aLLI O W Q x N � q 0 x Z o m Q w Lo W � F: z L CJ U U Z O a a i3 L t` O co � U I v� cz � O E c� O z W z I —I z W O `J cr) a N rr �� E� V1 � a z 0 E-+ y a m w O W N O CL co GCE SOB. N0.21040 COA. NO.29116 MAZEN MARIE, PE. FL. P1 # 60166) P-2 Wi .ICI i ,i ,. I JL IIL 1 ; L'LIllI&iA IL 1.: 1:1J Of NER.At MECHANICAL NOTES I OUfD00R 141R CALCULATIONS RVAC LOAD CALCULATION ISSUED FOR: REVIEW 11.01.2021 MECHANICAL NOTES: 2020 F.M.C. SECTION 403.3.1.1 IN GENERAL, PLANS AND DIAGRAMS ARE SCHEMATIC ONLY AND SHOULD NOT BE SCALED. ALL WALL MOUNTED THERMOSTATS AND/OR TEMPERATURE SENSORS SHALL BE INSTALLED AT AN ELEVATION OF 48" ABOVE FINISHED TENANT SPACE HAS: FLOOR TO THE TOP UNLESS OTHERWISE NOTED ON DRAWINGS. LOCATION OF THE WALL MOUNTED THERMOSTAT SHALL BE COORDINATED 639 SQ. FT. OF SALES WITH OTHER TRADES FOR A NEAT APPEARANCE. FINAL LOCATION OF THERMOSTAT SHALL BE SUBJECT TO THE APPROVAL OF THE 304 SQ. FT. OF STORAGE ROOM ENGINEER OR HIS REPRESENTATIVE IN THE FIELD. 45 SQ. FT. OF TOILET ROOM ALL SUPPLY AIR DIFFUSERS SHALL BE 4-WAY THROW UNLESS OTHERWISE NOTED. CONTRACTOR SHALL PAINT INSIDE EACH RETURN GRILLE'S PLENUM AND DUCT CONNECTION FLAT BLACK TO CONCEAL CONNECTION. COORDINATE AIR DEVICE LOCATIONS WITH LIGHTING PER TABLE 403.3.1.1 FIXTURES AND FIRE SPRINKLER HEADS. PRIOR TO INSTALLATION, THE CONTRACTOR IS TO REFER TO THE ARCHITECTURAL REFLECTED SALES OCCUPANT DENSITY IS (15 PERSON PER 1000 SQ. FT.) CEILING PLAN FOR ACTUAL FINAL LOCATIONS OF AIR DEVICES. STORAGE ROOM OCCUPANT DENSITY IS (0 PERSON PER 1000 SQ. FT.) CONTRACTOR SHALL PROVIDE A COPY OF THE TEST AND BALANCE REPORT BY AN AABC OR NEBB CERTIFIED AGENCY. ALL DUCTWORK TOILET ROOM OCCUPANT DENSITY IS (0 PERSON PER 1000 SQ. FT.) MUST BE INSTALLED 6" AWAY FROM ANY FIRE RATED WALL TO FACILITATE INSPECTION. SALES CALCULATION THE GENERAL CONTRACTOR IS RESPONSIBLE FOR ALL TRADES INSTALLATION SCHEDULES. FIXED WORK SUCH AS DUCTWORK AND SQ. FT. = 639 15 x 639 PLUMBING SHALL BE INSTALLED PRIOR TO ANY TRADE WORK THAT CAN BE EASILY RELOCATED OR OFFSET SUCH AS ELECTRICAL NUMBER OF OCCUPANT =------------- = 10 PERSON CONDUITS, SMALL WATER LINES ETC. 1000 PER EQUATION 4-1 VbZ RpPz + RaAz PENETRATIONS THROUGH SMOKE OR FIRE -RATED ASSEMBLIES: PENETRATIONS FOR PIPES, CONDUITS OR OTHER PURPOSES THROUGH ASSEMBLIES (FLOORS, ROOF, WALLS, PARTITIONS, ETC.) WITH A REQUIRED FIRE RESISTANCE RATING SHALL BE SEALED TO THE Vbz = 7.5 X 10 + 0.12 X 639 = 152 CFM PENETRATING MEMBER IN AN APPROVED MANNER WHICH MAINTAINS THE REQUIRED FIRE RESISTANCE RATING OF THE ASSEMBLY AS Vbz FOLLOWS: PER EQUATION 4-2 SECTION 403.3.1.3 V = --- WHERE HOLES FOR PENETRATIONS ARE FORMED CIRCULAR OR CORE -BORED, THE PENETRATION SHALL BE PROTECTED WITH °Z Ez FIRE -SEAL BRAND SMOKE AND FIRE STOP FITTINGS MFG. BY 0-Z GEDLEY, LINK SEAL BRAND BY THUNDER LINE OR AN EQUAL V0z = 152 / 0.8 = 190 CFM APPROVED BY ENGINEER. WHERE HOLES FOR PENETRATIONS ARE IRREGULAR (NON -CIRCULAR) IN SHAPE, THE PENETRATION SHALL BE PROTECTED WITH STORAGE ROOM CALCULATION DOW CORNING 3-6548, SILICONE RTV FOAM, 3M FIRE BARRIER PENETRATION SEAL SYSTEM OR AN EQUAL APPROVED BY THE SQ. FT. = 304 ENGINEER. NUMBER OF OCCUPANT = -- 0 0--x 304- 304 = 0 PERSON INTENT OF THESE NOTES AND MECHANICAL NOTES ON DRAWINGS IS TO CLARIFY THE SCOPE OF WORK AND ALERT CONTRACTOR OF 1000 EXISTING CONDITIONS. CONTRACTOR TO VISIT SITE AND VERIFY ALL CLEARANCES BEFORE FABRICATION OF DUCTWORK AND PROVIDE PER EQUATION 4-1 VZ Rbp P + R A ADDITIONAL OFFSET AND/OR CHANGES IN DUCT SIZES TO MEET FIELD CONDITIONS AND COORDINATE WITH ELECTRICAL, PLUMBING AND z a z FIRE PROTECTION SUBCONTRACTOR BEFORE ANY CONSTRUCTION WORK. Vbz = 0 X 0 + 0.012 X 304 = 4 CFM FLEXIBLE AND RIGID ROUND DUCT TAKE -OFFS FOR DIFFUSERS SHALL BE THE SAME SIZE AS DIFFUSER NECK. MAXIMUM FLEXIBLE DUCT PER EQUATION 4-2 SECTION 403.3.1.3 V =Vbz Oz LENGTH SHALL BE 8'- 0". Ez V°Z=0/0.8=5CFM UNLESS OTHERWISE NOTED, INSTALL DUCTWORK AS HIGH AS POSSIBLE, TIGHT TO BOTTOM OF STRUCTURE. COORDINATE DUCT ELEVATION WITH RAIN LEADERS, WATER PIPING, SANITARY DRAINS AND MAJOR ELECTRICAL CONDUITS. TOILET ROOM CALCULATION CONTRACTOR SHALL PROVIDE ALL SUPPLEMENTARY STEEL REQUIRED TO SUSPEND MECHANICAL EQUIPMENT AND MATERIALS. PROVIDE SQ. FT. = 45 0 x 45 MANUAL OR AUTOMATIC DAMPERS IN ALL OUTSIDE AIR DUCTS. NUMBER OF OCCUPANT =------------- = 1000 0 PERSON PROVIDE A TRAP IN ALL CONDENSATE PIPING LOCATED AT THE AIR HANDLING UNIT. INSULATE ALL CONDENSATE LINES WITH 1/2" THICK PER EQUATION 4-1 VbZ RpPz +RaAz CLOSED CELL FOAM INSULATION. Vbz=OXO+OX45 =OCFM PROVIDE A 4" HIGH CONCRETE HOUSEKEEPING PAD UNDER ALL MECHANICAL EQUIPMENT, UNLESS OTHERWISE NOTED. PADS SHALL BE 4" Vbz LARGER THAN THE EQUIPMENT ON ALL SIDES. PER EQUATION 4-2 SECTION 403.3.1.3 VOZ --- Ez UNLESS OTHERWISE NOTED, ALL UNDERGROUND PIPING SHALL HAVE A MINIMUM OF 3'-0" OF COVER. V = 0 / 0.8 = 0 CFM ALL MECHANICAL WORK SHALL MEET ALL THE REQUIREMENTS OF THE "2007 FLORIDA MECHANICAL CODE" AND ALL UPDATED O2 AMENDMENTS. TOTAL CFM REQUIRED FOR ALL AREAS = RECTANGULAR SUPPLY, RETURN, AND TRANSFER AIR DUCTS SHALL BE CONSTRUCTED OF 1.5" THICK DUCT BOARD AND CONFORM WITH UL 190 + 5 = 195 CFM STANDARDS FOR SAFETY AIR DUCT, NO. 181, 1967 ESTABLISHED FOR CLASS 1 AIR DUCTS. CONSTRUCTION SHALL COMPLY WITH 195 CFM OF OUTSIDE AIR IS REQUIRED RECOMMENDATIONS AND DETAILS IN SMACNA BULLETIN 15, LATEST REVISION AND MANUFACTURER'S RECOMMENDATIONS. ALL JOINTS 200 CFM OF OUTSIDE AIR IS PROVIDED THRU RTU-1 SHALL BE SECURELY TAPED WITH FASSON 0810 OR APPROVED EQUAL PRESSURE SENSITIVE TAPE. METAL TO FIBERGLASS CONNECTIONS TO BE MADE USING 3" WIDE GLASS FABRIC TAPE WITH FOSTER 30/35 MASTIC OR EQUAL. SUPPORT DUCTS WITH 1X2X1 22 GAUGE MINIMUM CHANNELS AND STRAP OR 12-GAUGE WIRE FROM BUILDING CONSTRUCTION. SUSPEND FROM JOISTS WITH BEAM CLAMPS. PROVIDE HOT DIPPED STEEL FASTENERS, ANCHORS, RODS, STRAPS, TRIM AND ANGLES FOR SUPPORT OF DUCTWORK. PROVIDE ADDITIONAL DUCTWORK AND PIPING SUPPORTS ON BOTH SIDES AND WITHIN 18" OF FIRE RATED WALL. DUCTWORK OR PIPING SHALL NOT BE SUPPORTED FROM ANY FIRE RATED WALL. TURNING VANES SHALL BE PROVIDED IN ALL SUPPLY DUCT RECTANGULAR ELBOWS WITH ANGLES BETWEEN 45 DEGREES AND LESS THAN 90 DEGREES PER FIG. 2-5 OF THE SMACNA MANUAL. DUCT DIMENSIONS SHOWN ON DRAWINGS ARE CLEAR INSIDE DIMENSIONS. MECHANICAL CONTRACTOR SHALL SIZE AND INSTALL REFRIGERANT PIPING PER MANUFACTURER'S RECOMMENDATIONS. REFRIGERANT PIPING SHALL BE TYPE "K" COPPER WITH BRAZED JOINTS. APPLY 3'4" CLOSED CELL INSULATION ON COMPRESSOR SUCTION LINE. DUCTWORK, DIFFUSERS, REGISTERS, GRILLES, AND OTHER ITEMS OF THE AIR HANDLING SYSTEM SHALL NOT BE SUPPORTED BY THE CEILING OR CEILING SUSPENSION SYSTEM. O ROOF TOP UNI JI/i� M W0. KA! � FUC. CWU NOTE: ALL DUCT WRAP SHALL BE SEALED WITH GLASS FAB AND MASTIC. NET HEATING ENTERING COOLING CAPACITY ELECTRICAL MARK MFG/MODEL DISCHARGE TONS ESP CFM OUTSIDE AIR CAPACITY EER KW CRATED MCA/ UNIT WEIGHT SPIN -IN FITTING WITH VOLUME WRAPPED SHEETMETAL AIR CFM CONDITIONS (MBH) VOLTAGE VOLT / PH / Hi MOCP (LBS) EXTRACTOR AND \ DUCT SEE NOTE RTU-1 CARRIER SOHCA04 DOWNFLOW 3 1.0 1200 200 80°F DB 67°F WB 36 12.5 8.7 @ 208 208 / 3 / 60 33/35 458 BALANCING #6 IN GENERAL OR EQ. 0 95 OF AMBIENTI DAMPER HAVC. SPECS. HARD DUCT ACCESSORIES PROVIDED AND INSTALLED BY TENANT CONTRACTOR: HORIZONTAL 1. NEW ROOF CURB, CARRIERITHYBAR TC-05 14 GAUGE CURB CERTIFIED FOR LOCAL WIND LOAD (175 MPH) AND ATTACHMENT KIT WITH UNIT/PANEL WIND KIT. 2. DRAIN PAN OVERFLOW SWITCH FOR UNIT SHUT DOWN. HARD ELBOWS ACCESSORIES PROVIDED BY TENANT FOR TENANT CONTRACTOR INSTALLATION: WHERE BEND DUCT CLAMP 1. DIFFERENTIAL ENTHALPY ECONOMIZER WITH BAROMETRIC RELIEF. EXCEEDS 450 2. INSTALL EMS CONTROLS PACKAGE. 3. LOUVERED CONDENSER COIL GUARDS. DUCT INSULATED FLEXIBLE 4. UNIT MOUNTED NON POWERED WEATHERPROOF GFCI OUTLET. CLAMP DUCT 5. UNIT MOUNTED DISCONNECT SWITCH. / 1-1/2" INSULATION WITH (VOTE: VAPOR BARRIER COVERING CONTRACTOR SHALL BE RESPONSIBLE FOR ALL STARTUP AND WARRANTY WORK. VERIFY ELECTRICAL POWER PRIOR TO TOP SIDE OF DIFFUSER INSTALLING UNITS. FAILURE TO DO SO SHALL RESULT IN CONTRACTOR FURNISHING CORRECT UNITS OR POWER AT NO FROM NECK TO CEILING AND SEALED TO DUCT ADDITIONAL COST TO TENANT. INSULATION. (R=6.0) G UMOOM WATUST FIN SCNEM FLEX DUCT INSTL. PETAIL MARK MANUFACTURER MODEL # TYPE CFM E.S.P. WATTS VOLTS/pf B.D.D. DRIVE REMARKS SCALE: NONE EF-1 GREENHECK SP-C CEILING 50 0.125 46 115/1 NO DIRECT 1,2 1. PROVIDE WITH FACTORY SPEED CONTROLLER FOR BALANCING, AND FACTORY DISCONNECT. MECHANICAL LEGEND 2. INTERLOCK WITH LIGHT SWITCH. SYMBOL DE'SCRIP AIR Ii��cc .1�/i SV�I pper�'� U NEW DUCTWORK, PIPING, OR EQUIPMENT MARK TYPE MATERIAL FINISH ACCESSORIES MANUFACTURER REMARKS AND MODEL EXISTING DUCTWORK, PIPING, OR EQUIPMENT TO REMAIN MOUNTED ALUMINUM ALUMINUM ASD TITUS SUPPLY OR OUTSIDE AIR DUCT SECTION ODUCT B SUPPLY S300FL X X 26 ASD DIFFUSER OR EQUAL RETURN OR EXHAUST DUCT SECTION SUPPLY ALUMINUM BAK. WHT. O OBD TfmS PAS 1 & 2 DIFFUSER ENAMEL 12X12 DUCTWORK TRANSITION RETURN BAK. WHT. OBD TITUS D REGISTER ALUMINUM ENAMEL PAR 1 MANUAL AIR VOLUME CONTROL DAMPER 24X24 AIR DEVICE NOTES: 1. CONTRACTOR TO COORDINATE AIR DEVICE FRAMES WITH CEILING AND/OR WALL TYPE. ® m SUPPLY AIR DEVICE. CLEAR TRIANGLE SIDES INDICATE 2. NECK SIZES AND CFM QUANTITIES SHOWN ON MECHANICAL FLOOR PLANS. AIR FLOW PATTERN z RETURN OR EXHAUST AIR DEVICE OUTSIDE AIR INTAKE ROOF CAP NEW CONNECTION TO EXISTING EQUIPMENT _- UNDERCUT DOOR 3/4" (MINIMUM) Q WALL MOUNTED THERMOSTAT SMOKE DETECTOR CD CEILING DIFFUSER RRC RETURN REGISTER AT CEILING BASIS OF DESIGN: SUMMER WINTER HEATING LOAD: OUTSIDE AIR ROOF GLASS WALLS COOLING LOAD: SENSIBLE LOAD: OUTSIDE AIR ROOF GLASS WALLS PEOPLE LIGHTING > ;Al2►i11[97_1f OUTSIDE PEOPLE OUTSIDE 917 db, 777 wb 40'F db INSIDE 75-F db, 50% R.H. 70'F Fdb 200 CFM X 30' X 1.08 = 6480.00 BTUH 1010 SQ.FT. X 30' X 0.031 = 939.30 BTUH 148 SQ.FT. X 30' X 1.16 = 5150.40 BTUH 503 SQ.FT. X 30' X 0.36 = 5432.40 BTUH TOTAL SPACE HEAT LOAD .... = 18002.10 BTUH 200 CFM X 16' X 1.08 = 3456.00 BTUH 1010 SQ.FT. X 16' X 0.031 = 500.96 BTUH 148 SQ.FT. X 16' X 1.16 = 2746.88 BTUH 503 SQ.FT. X 16' X 0.36 = 2897.28 BTUH 10 PEOPLE X 250 = 2500.00 BTUH 330 WATT X 3.412 = 1125.96 BTUH SENSIBLE TOTAL ..................= 13227.08 BTUH 200 CFM X 0.68 X 54 = 7344.00 BTUH 10 PEOPLE X 250 = 2500.00 BTUH LATENT TOTAL .....................= 9844.00 BTUH GRAND TOTAL COOLING LOAD = 23071.08 BTUH 2 TONS REQUIRED 3 TONS PROVIDED glll � NEW UNIT GASKET NEW UNIT BASE RAIL EXIST.MANUFACTURED ,�1/4" x #28 x 6" TEK ROOF CURB HEX STEEL -ZINC P.T. NAILER FASTENER -ALL FOUR HARD INSULATION __ SIDES 16" MAXIMUU M SPACING CANT. G.C. VERIFY. EXIST. ROOFING TOP EXIST. 3/8" MIN THREADED ROD CAP & INSULATION.6.C. VERIFY WITH -IN 12" EA. CORNER THROUGH CURB STEEL AND BUILDING ----�--�---�-- -----------�-------- STRUCTURE. G.C. VERIFY EXIST. WELDED STEEL L4X4 EQUIPMENT FRAME BELOW oo" L DECK & RTU CURB STEEL TYPICAL METAL DECK PAN ROOF SUPPORT EXIST. 2"x2"4/4" STIFFENER -� STRUCTURAL MIN. @ EACH LOCATION OF L4X4 STEEL ANGLE AT CROSSING STEEL JOIST POINT OF EXIST.ROOF TRUSSES. G.C. VERIFY EQUIPMENT ATTACHMENT TO EXIST ROOF CURB HOLD DOWN N.T.S. V I I MAX. 200 TRANSITION 0.25 D (4" MIN. PER SMACNA) RECTANGULAR DUCT o to 0 N VOLUME DAMPER CONICAL FITTING WITH LOCKING TYPE VOLUME DAMPER. OR SIDE WALL TAKEOFF EQUAL TO FLEXMASTER STO. `FLEX DUCT OR ROUND SHEET METAL DUCT. FLEX DUCT MAX. 5'-0" Ld LONG, USE CLAMP TO ATTACH FLEX DUCTS AND SEAL. SUPPORT DUCT EVERY FOUR FEET FROM STRUCTURE 6IA140H DUCT DETAILS NO SCALE EXI 50 CFM 50 CFM O O 00 50 CFM 50 CFM CB) OB 1000 CFM R/A 0 1OX20 UP TO RTU-1 0 O g3 1000 CFM T R/A 0 to �= CFM G RTU-1 XH' 50 0 CFM io 100 CFM 100 CFM 100 CFM 100 CFM 100 C� 100 CFM O O O 150 CF� 150 CFM O O EXIT 0 MECHANICAL PLAN SCALE: 1/4" = V-0" 1200 CFM 16X12 SUPPLY DUCT DOWN FROM RTU-1 MECHANICAL PLAN NOTES OPROVIDE AND INSTALL RTU PER SCHEDULE & DETAIL. O2 PROVIDE & INSTALL FLEXIBLE DUCT DOWN TO SUPPLY DIFFUSER. O3 PROVIDE AND INSTALL ZONE SENSOR THERMOSTAT, COORDINATE LOCATION WITH OWNER OPROVIDE AND INSTALL RESTROOM EXHAUST FAN PER SCHEDULE. RUN 5" EXHAUST DUCT TO ROOF AND INSTALL ROOF CAP. 10'-0" MINIMUM SEPARATION IS REQUIRED BETWEEN EXHAUST OUTLET AND AIR -INTAKES BEFORE PERMITTING OR START OF CONSTRUCTION: 1. TENANT TO ACQUIRE LANDLORD WRITTEN APPROVAL OF ALL PROPOSED ALTERATIONS. 2. CONTRACTOR TO VERIFY ALL EXISTING DIMENSIONS AND ELEVATIONS. 3. CONTRACTOR TO COORDINATE ROUGH WINDOW/ DOOR OPENINGS SIZE W/ MFR SPEC: Z F a Fr U In W 0 �D "t O 0 Q co co O w x a z Q x U O w Z Ia U w W O m � a � W Z F Lo > . __j 0) Lo U U Z a IL t3i �O � U co H co I r-o �jE O w ;T-1 z W H W r- co co F� Gj T� H rn V 1 (u a O E- a; P. m� O 8� a O Cq a CID JOB. N0. 21040 G�`I \v � COA. N0.29116 MAZEN MARIE, PE. L. E # 60166) _ �c '�,il11111\\ M1.0 F CVTCT KA=D Cr%rVLT /YV11)rlTKIATC ELECTRICAL POWER PLAN SCALE: 1/4" = V-0" 7 OR DISPLAY LED LIGHTS, IERIFY NUMBER & .00ATIONS WITH OWNER A-19 VIA T/C T Ate. IM �' s kl'04" i� rIA . O TYP. J � TIE TO - - A-13 J O ® N/L O TYPO O A-11 Lai TIE TO A-15 O TELEPHONE AND DATA SCHEDULE CALLOUT SYMBOL NOTE QUANTITY DATA OUTLET 4 (1) CAT5E 24AWG 350MHZ 0 (AT OWNER'S OPTION) UTP STANDED. 4 PAIRS IN WALL RATED RJ45 PLUG DUPLEX TELEPHONE/ (2) CAT5E 24AWG 350MHZ 1 DATA OUTLET UTP STANDED. 4 PAIRS IN WALL RATED 1-RJ45 PLUG AND 1-RJ11 PLUG BRANCH CIRCUIT FEEDER SCHEDULE AMP/POLE CONDUCT. GND. CONDUCT. CON. 15A/1P OR 15A/2P (2) #12 #12 1/2" 20A/lP OR 20A/2P (2) #12 #12 1/2" 15A/3P OR 20A/3P (3) #12 #12 1/2" 25A/1P OR 25A/2P (2) #10 #10 3/4" 30A/1P OR 30A/2P (2) #10 #10 3/4" 25A/3P OR 30A/3P (3) #10 #10 3/4" 35A/1P OR 35A/2P (2) #8 #10 3/4" 40A/lP OR 40A/2P (2) #8 #10 3/4" 35A/3P OR 40A/3P (3) #8 #10 3/4" 45A/1P OR 45A/2P (2) #6 #10 1" 50A/1P OR 50A/2P (2) #6 #10 1" 45A/3P OR 5OA/3P (3) #6 #10 1" 60A/lP OR 60A/2P (2) #4 #8 1" 60A/3P (3) #4 #8 1 1/4" 70A/3P OR 80A/3P (3) #4 #8 1 1/4" 9OA/3P (3) #3 #8 1 1/4" 100A/3P OR 11OA/3P (3) #2 #6 1 1/2" 125A/3P (3) #1 #6 1 1/2" - PROVIDE BRANCH CIRCUIT FEEDERS AS NOTED ABOVE UNLESS NOTED OTHERWISE SYMBOLS 2'X4' NIGHT LT (N/L) DUPLEX RECEPTACLE WITH 6 120 V, 20 AMPERE RATING, 6GFI DUPLEX W/GRND F. INTERRUPTER QUADRUPLEX WITH 120V, 20 A. (QUADRUPLEX W/GRND F. INTERRUPTER WHERE NOTED AS "GFI" O CEILING/WINDOW OUTLETS. ABOVE CEILING. OJUNCTION BOX 01 DISCONNECT SWITCH Q SURFACE MOUNTED POWER PANEL TWO WAY SWITCH TWO WAY SWITCH, WITH OCCUPANCY OS SENSOR (WHO WATER HEATER MANUAL PULL STATION - 270-SPO 42" A.F.F. r� HORN/STROBE-792-7A-006 80" A.F.F. El FAN SHUT DOWN RELAY W/ ENCLOSURE-M R-199X-13/C Imo_ DUCT SMOKE DETECTOR 6264E-001/ �- 6260A-100/6261-003-6251B-001A REMOTE INDICATOR/TEST STATION - 6262A-001 CONCEALED IN WALL, CEILING OR UNDER GROUND CONDUIT RUN CONSISTING OF: Z - GROUND CONDUCTOR III - SMALL LINES INDICATE POWER NON GROUNDED CONDUCTORS. - BIG LINE INDICATES NEUTRAL CONDUCTOR LIGHTING PLAN FIXTURE SCHEDULE SYMBOL DESCRIPTION MANUFAC. CATALOG LAMP MTG. VOLT REMARKS LFIA� / WATT O 2X4 SUSPENDED LED HIGH BAY LITHONIA IBE L48 12000LM L/LENS MD MVOLT GZ10 40K 80CRI DWH LED (39W) 4000 LUMEN SUSPENDED 120 - PROVIDE ALL REQ'D HARDWARE - (1) EM / NIGHT LIGHT REQ'D AT 1 83 ENTRANCE O 2X2 RECESSED LED TROFFER LITHONIA 2GTL2 LP835 LED (39.6W) 4000 LUMEN RECESSED 120 - PROVIDE ALL REQ'D HARDWARE 1 40 1 PER TRACK LIGHT WAC LIGHTING H-8010-30-BK-12 LED TRACK 120 TRAC HEAD 11 PENDANT LED LIGHT ® FIXTURE COORDINATE WITH OWNER LED PENDANT 120 -PROVIDE ALL REQ'D HARDWARE 1 23 EXISTING EXTERIOR WALL LED WALL 120 1 10 MOUNTED LIGHT FIXTURE EMERGENCY LIGHT SURELITE CC-2 FURNISHED UNIVERSAL 120 90 MINUTE BATT. BACKUP POWER N/A 3 W/UNIT EX EXIT LIGHT ATLITE PNLRU FURNISHED UNIVERSAL 120 90 MINUTE BATT. BACKUP POWER N/A 5 W/UNIT ® CEILING EXHAUST FAN 120 VENTED TO OUTSIDE SEE MECHANICAL DRAWINGS NOTES: 1. ELECTRICAL CONTRACTOR TO INQUIRE ABOUT LOCAL REBATES ON LIGHT FIXTURES. 2. INSTALLATION OF LIGHT FIXTURES SHALL BE ACCORDING TO MANUFACTURER'S RECOMMENDATIONS AND ACCORDING TO CODE REQUIREMENTS. FOR SIGN ELECTRICAL LIGHTING PLAN SCALE: 1/4" = 1'-0" H.V.AC. DUCT SMOKE DETECTORS AND REMOTE AUDIO/ VISUAL ALARM TO BE FURNISHED AND INSTALLED BY MECHANICAL CONTRACTOR HARED BY ELECTRICAL CONTRACTOR. DUCT DETECTORS ARE REMOTE T STAND ALONE TYPE UNITS do SHALL BE INTERLOCKED SO THAT SMOKE DETECTION IN ANY UNIT SHALL SHUT DOWN ALL OTHER UNITS CONFIRM ALL EQUIPMENT TYPES do LOCATIONS WITH OWNER BEFORE INSTALLATION. ELECTRICAL OUTLETS SHOWN ARE MINIMUM. ALL PLUMBING, PIPING CONDUITS OR OUTLETS SHALL BE MADE OF NON- COMBUSTIBLE MATERIALS & SEALED TIGHT. OTHER OPTIONS SHOULD BE CONSIDERED SUCH AS BUILDING FRAME WALL ADJACENT TO FIRE WALL TO RUN ALL PLUMING do ELECTRICAL CONDUITS. A KEYNOTES OPROVIDE LOCK TAB AT CIRCUITS FEEDING NIGHT, EXIST AND EMERGENCY LIGHTS. ALL NIGHT, EXIT AND EMERGENCY LIGHTS SHALL BE WIRED AHEAD OF ANY LOCAL CONTROL SWITCHES. O2 THE CONTACTOR SHALL FURNISH AND INSTALL ALL LIGHT FIXTURES AS SHOWN ON THE LIGHTING SCHEDULE; HOWEVER CONTRACTOR MUST COORDINATE WITH THE OWNER AND OBTAIN APPROVAL ON ALL MODEL NUMBERS BEFORE PURCHASING ANY LIGHT FIXTURES. ORESTROOM LIGHT AND EXHAUST FAN SHALL BE OPERATED BY THE SAME SWITCH. MAKE ALL CONNECTIONS AS REQUIRED. O4 COORDINATE WITH THE OWNER AND INSTALL NEW SWITCH LEG FOR LIGHTING CONTROL SYSTEM AS SHOWN. DETERMINE LOCATIONS OF ALL SWITCHES AT SITE. �5 THE CONTRACTOR SHALL VERIFY AND REUSE EXISTING 200 AMP, 120/208V, 3PH, 4W POWER SUPPLY IN COMPLIANCE WITH THE RISER DIAGRAM, PANEL SCHEDULE & AS DESCRIBED BELOW: ■ VERIFY THAT ALL EXISTING EQUIPMENT AT THE LANDLORD'S METER CENTER INCLUDING MAIN DISCONNECT AND METER ARE IN COMPLIANCE WITH RISER DIAGRAM AND N.E.0 APPLICABLE CODE. IF NOT UPGRADE THEM PER RISER DIAGRAM. ■ REUSE EXISTING PANEL "A" IN COMPLIANCE WITH THE RISER DIAGRAM AND PANEL SCHEDULE. ALL BREAKERS IN PANEL SHALL BE BOLTED TYPE. REFER TO FOOT NOTES AT PANEL SCHEDULE. ■ THE GROUNDING SYSTEM SHALL BE INSTALLED IN COMPLIANCE WITH N.E.C. STD #250 REQUIREMENTS. OALL OUTLETS WITHIN 6' OF ANY SINK SHALL BE GFI OUTLETS TO COMPLY WITH N.E.C. STD. #210.8(B)(2). OTHE CONTRACTOR SHALL COORDINATE LOCATIONS OF ALL OUTLETS WITH THE OWNER BEFORE ROUGH IN AND INSTALLING OUTLETS, THIS IS TYPICAL. OFURNISH AND INSTALL POWER SUPPLY AND DISC. SWITCH FOR RTU-1. COORDINATE WITH EQUIPMENT SUPPLIER. IF NOT EXISTING, INSTALL A WEATHER PROOF GFI OUTLET NEAR UNIT. MAKE ALL CONNECTIONS AS REQUIRED. (D COORDINATE WITH THE PLUMBING PLANS AND FURNISH AND INSTALL A DISCONNECT SWITCH FOR THE WATER HEATER. THE CONTRACTOR SHALL PROVIDE ALL CONTROLS AND CONNECTIONS AS REQUIRED TO MAKE SURE IT FUNCTIONS AS REQUIRED. 10 CONTRACTOR SHALL COORDINATE WITH OWNER AND PROVIDE A TIME CLOCK T/C TO CONTROL EXTERIOR LIGHT AND STOREFRONT SIGN. INSTALL JUNCTION BOX AND SWITCH FOR STORE SIGN CIRCUIT AS REQUIRED. 11 AT OWNER'S DISCRETION, ROUTE ALL LIGHTING/SIGN CIRCUITS THROUGH A WATTSTOPPER 8 RELAY PEANUT PANEL LP8S-8-G-115 AND PROVIDE AS-100-W SWITCHES FOR ALL LIGHTING SWITCHES. (FOR LOCAL CONTROL AND TIME OF DAY OVERRIDE ) 12 INSTALL NEW LIGHT SWITCH WITH OCCUPANCY SENSOR. ALL ROOM LIGHTING CONTROLS SHALL COMPLY PER THE FLORIDA BUILDING CODE 2020 ENERGY CONSERVATION CHAPTER 4 SECTION C405. 13 LIGHTING CONTROLS SHALL BE INSTALLED IN COMPLIANCE WITH 2O20 FBC ENERGY CONSERVATION. THIS IS TYPICAL. 14 CONTRACTOR SHALL COORDINATE WITH OWNER, LANDLORD AND INSTALL NEW LOW VOLTAGE EQUIPMENT AS REQUIRED. EXTEND TELEPHONE CONDUIT AND CABLE TO TEL. BD "TTB" IN OFFICE. COORDINATE ALL LOW VOLTAGE REQUIREMENTS WITH OWNER. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL CABLES AND DATA/TEL. OUTLETS. THE TELEPHONE AND LOW VOLTAGE SYSTEMS SHALL BE COMPLETE AND FUNCTIONAL. 15 PROVIDE A MINIMUM 1/2" CONDUIT W/WIRE FROM TELEPHONE OUTLET BACK TO TELEPHONE BOARD LOCATED IN OFFICE AREA. THIS IS TYPICAL FOR ALL TELEPHONE OUTLETS. 16 PROVIDE KEY -LOCK TABS AT THESE CIRCUITS. ROUTE CASH REGISTER CIRCUITS WITH AN ISOLATED GROUND CONDUCTOR. 17 ALL CONDUIT PENETRATIONS THROUGH CASEWORK SHALL BE CLEAN, TIGHT AND SEALED WITH WHITE SILICONE. THIS IS TYPICAL. 18 FURNISH AND INSTALL DUCT SMOKE DETECTORS, RELAY AND REMOTE INDICATOR FOR RTU-1. TIE RELAY INTO DUCT MT'D SMOKE DETECTOR WHICH WHEN ACTIVATED WILL SHUT DOWN THE A/C UNIT FAN AND SIGNAL LANDLORD'S MASTER FIRE ALARM CONT. PANEL, IF REQ'D. PROVIDE CONDUIT, WIRES AND MAKE ALL CONNECTIONS AS REQUIRED. DETERMINE BEST LOCATION OF REMOTE INDICATOR AT SITE. GENERAL NOTES: 1. CONTRACTOR SHALL REVIEW THE SPECIFICATIONS, GENERAL NOTES, KEY NOTES, ELECTRICAL PLANS AND THE LANDLORD DESIGN CRITERIA BEFORE BIDDING AND STARTING ANY CONSTRUCTION WORK. 2. ALL INSTALLATION SHALL COMPLY WITH THE REQUIREMENTS OF THE DESIGN DOCUMENTS, LANDLORD DESIGN CRITERIA AND N.E.C. REQUIREMENTS. 3. CONTRACTOR SHALL VERIFY AND REUSE EXISTING METER AND POWER SUPPLY IN COMPLIANCE WITH THE RISER DIAGRAM. THIS WILL INCLUDE ELECTRIC METER, BREAKER, POWER SUPPLY FEEDERS AND CONDUITS AND POWER PANEL. 4. CONTRACTOR SHALL PROVIDE NEW WIRING AND BREAKERS FOR ALL NEW LOADS AS SHOWN ON PANEL SCHEDULES. 5. CONTRACTOR SHALL PROVIDE ALL CONDUITS, WIRING, AND OUTLETS FOR TELEPHONE AND LOW VOLTAGE SYSTEMS TO BE FULLY FUNCTIONAL. COORDINATE WITH TENANT. 6. INTERIOR TELEPHONE AND DATA WIRING SHALL INCLUDE FURNISHING AND INSTALLING ALL TELEPHONE AND DATA JACKS, AND COVER PLATES AS REQUIRED. COORDINATE WITH OWNER. 7. LABEL ALL ELECT. EQUIPMENT WITH ENGRAVED BAKELITE NAMEPLATE OR EMBOSSED PLASTIC NAME STRIP. LABEL ALL PANELS AS SHOWN ON THE RISER DIAGRAM. 8. FURNISH NEW TYPE WRITTEN CIRCUIT DIRECTORY CARDS FOR ALL PANELS. LIST ALL USED AND SPARE CIRCUITS. 9. CONTRATCOR SHALL FURNISH AND INSTALL POWER SUPPLY AND DISCONNECT SWITCHES FOR RTUS 10. ALL ELECTRICAL DEVICES AND EQUIPMENT SHALL BE EFFECTIVELY GROUNDED IN ACCORDANCE WITH N.E.C. REQUIREMENTS. ALL BRANCH CIRCUITS SHALL HAVE A SEPARATE GREEN INSULATED GROUND WIRE IN EACH CONDUIT RUN. 11. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL ELECTRICAL CONNECTIONS U.N.O. 12. CONTRACTOR SHALL BE RESPONSIBLE FOR COMMUNICATION WITH THE PROPERTY OWNER'S PERSONNEL TO REVIEW CONTRACT DOCUMENTS PRIOR TO INSTALLATION. 13. CONTRACTOR TO SEAL ALL WALL PENETRATIONS IN AN APPROVED MANNER TO INSURE THE FIRE RATING INTEGRITY OF THE INVOLVED AREAS. 14. COORDINATE FINAL INSTALLATION REQUIREMENTS WITH PROPER AUTHORITIES. 15. CONTRACTOR, UPON COMPLETION OF HIS WORK, SHALL BE RESPONSIBLE TO PROVIDE ANY AND ALL CERTIFICATIONS. 16. ALL CONDUIT RUNS SHALL BE PARALLEL OR PERPENDICULAR TO THE WALLS. 17. ALL CABLES AND WIRES SIZES SHALL COMPLY WITH N.E.C. TABLE 310-16. MINIMUM SIZE OF CONDUCTOR SHALL BE #12 AWG CU. NO. 10 WIRES SHALL BE USED IN PLACE OF #12 FOR CIRCUITS LONGER THAN 75 FEET FROM PANEL TO LOAD. ALUMINUM CONDUCTOR SHALL NOT BE PERMITTED. WIRE INSULATION SHALL BE THHN OR THWN. 18. ALL INTERIOR WIRING SHALL BE CONCEALED AND IN GAL. STEEL OR EMT CONDUITS AND IN COMPLIANCE WITH THE N.E.C. 19. CONTRACTOR MAY USE FLEXIBLE CONDUIT FROM JUNCTION BOX TO THE LIGHTING FIXTURE, BETWEEN LIGHTING FIXTURES, AND TO OTHER DEVICES PROVIDED THE LENGTH OF THE FLEXIBLE CONDUIT IS NOT MORE THAN 6 FEET. 20. BX, ROMAX, MC OR ANY OTHER ARMORED OR METAL -CLAD WIRING SHALL NOT BE PERMITTED. REVIEW DATE:�- CITY ,7 - ?I;PHYR IL BUIP OFFICIAL ,)-;' BEFORE PERMITTING OR START OF CONSTRUCTION: 1. TENANT TO ACQUIRE LANDLORD WRITTEN APPROVAL OF ALL PROPOSED ALTERATIONS. 2. CONTRACTOR TO VERIFY ALL EXISTING DIMENSIONS AND ELEVATIONS. 3. CONTRACTOR TO COORDINATE ROUGH WINDOW/ DOOR OPENINGS SIZE W/ MFR SPEC: ISSUED FOR: REVIEW 11.01.2021 m Ww>-to-0ztn Q co co � F=•I O I --I a I- f --I E � W x N U� Q a W � ti I> z Z F U< O Lo r-I Lo H H a a 0 GCE MAZEN MA (FL. RE # Z F a � U N W 0 8 Lp �$ I` O c' U cr) I °z 101 I r- C\2 O �a EO w z rl- -4 co 00 CYJ a r� N U E- a E4 x 0 S.: Pr. O W 0. :` co JOB. NO.2104 COA. NO. 291: ►li f1 PE. L GVrcr urren ce%o-wor f`Mnr%Tk1AT0 w NE ELECTRICAL POWER PLAN SCALE: 1/4" = V-0" )ISPLAY LED LIGHTS, Y NUMBER & (IONS WITH OWNER ELECTRICAL LIGHTING PLAN SCALE: 1/4" = 1'-0" TELEPHONE AND DATA SCHEDULE CALLOUT SYMBOL NOTE QUANTITY DATA OUTLET 4 (1) CAT5E 24AWG 350MHZ 0 (AT OWNER'S OPTION) UTP STANDED. 4 PAIRS IN WALL RATED RJ45 PLUG DUPLEX TELEPHONE/ DATA OUTLET (2T)P CST 5E 2 A4G 3 ROM HZ IN WALL RATED 1—RJ45 PLUG 1 AND 1—RJ11 PLUG BRANCH CIRCUIT FEEDER SCHEDULE AMP/POLE CONDUCT. GND. CONDUCT. CON. 15A/1P OR 15A/2P (2) #12 #12 1/2" 20A/1P OR 20A/2P (2) #12 #12 1/2" 15A/3P OR 20A/3P (3) #12 #12 1/2" 25A/1P OR 25A/2P (2) #10 #10 3/4" 30A/1P OR 30A/2P (2) #10 #10 3/4" 25A/3P OR 30A/313 (3) #10 #10 3/4" 35A/1P OR 35A/2P (2) #8 #10 3/4" 40A/1P OR 40A/2P (2) #8 #10 3/4" 35A/3P OR 40A/3P (3) #8 #10 3/4" 45A/1P OR 45A/2P (2) #6 #10 1" S0A/1P OR 5OA/2P (2) #6 #10 1" 45A/3P OR 50A/313 (3) #6 #10 1" 60A/1P OR 60A/2P (2) #4 #8 1" 60A/3P (3) #4 #8 1 1/4" 70A/3P OR 80A/3P (3) #4 #8 1 1/4" 90A/3P (3) #3 #8 1 1/4" 10OA/3P OR 11OA/3P (3) #2 #6 1 1/2" 125A/3P (3) #1 #6 1 1/2" - PROVIDE BRANCH CIRCUIT FEEDERS AS NOTED ABOVE UNLESS NOTED OTHERWISE KEYNOTES ISSUED FOR: REVIEW 11.01.2021 OPROVIDE LOCK TAB AT CIRCUITS FEEDING NIGHT, EXIST AND EMERGENCY LIGHTS. ALL NIGHT, EXIT AND EMERGENCY LIGHTS SHALL BE WIRED AHEAD OF ANY LOCAL CONTROL SWITCHES. O2 THE CONTACTOR SHALL FURNISH AND INSTALL ALL LIGHT FIXTURES AS SHOWN ON THE LIGHTING SCHEDULE; HOWEVER CONTRACTOR MUST COORDINATE WITH THE OWNER AND OBTAIN APPROVAL ON ALL MODEL NUMBERS BEFORE PURCHASING ANY LIGHT FIXTURES. ORESTROOM LIGHT AND EXHAUST FAN SHALL BE OPERATED BY THE SAME SWITCH. MAKE ALL CONNECTIONS AS REQUIRED. OCOORDINATE WITH THE OWNER AND INSTALL NEW SWITCH LEG FOR LIGHTING CONTROL SYSTEM AS SHOWN. DETERMINE LOCATIONS OF ALL SWITCHES AT SITE. OTHE CONTRACTOR SHALL VERIFY AND REUSE EXISTING 200 AMP, 120/208V, 3PH, 4W POWER SUPPLY IN COMPLIANCE WITH THE RISER DIAGRAM, PANEL SCHEDULE & AS DESCRIBED BELOW: IN VERIFY THAT ALL EXISTING EQUIPMENT AT THE LANDLORD'S METER CENTER INCLUDING MAIN DISCONNECT AND METER ARE IN COMPLIANCE WITH RISER DIAGRAM AND N.E.0 APPLICABLE CODE. IF NOT UPGRADE THEM PER RISER DIAGRAM. ■ REUSE EXISTING PANEL "A" IN COMPLIANCE WITH THE RISER DIAGRAM AND PANEL SCHEDULE. ALL BREAKERS IN PANEL SHALL BE BOLTED TYPE. REFER TO FOOT NOTES AT PANEL SCHEDULE. ■ THE GROUNDING SYSTEM SHALL BE INSTALLED IN COMPLIANCE WITH N.E.C. STD #250 REQUIREMENTS. OALL OUTLETS WITHIN 6' OF ANY SINK SHALL BE GFI OUTLETS TO COMPLY WITH N.E.C. STD. #210.8(B)(2). 7 THE CONTRACTOR SHALL COORDINATE LOCATIONS OF ALL OUTLETS WITH THE OWNER BEFORE ROUGH IN AND INSTALLING OUTLETS. THIS IS TYPICAL. cr w > — cn — o Z cn OFURNISH AND INSTALL POWER SUPPLY AND DISC. SWITCH FOR RTU-1. COORDINATE WITH EQUIPMENT SUPPLIER. IF NOT EXISTING, INSTALL A WEATHER PROOF GFI OUTLET NEAR UNIT. MAKE ALL CONNECTIONS AS REQUIRED. O9 COORDINATE WITH THE PLUMBING PLANS AND FURNISH AND INSTALL A DISCONNECT SWITCH FOR THE WATER HEATER. THE CONTRACTOR SHALL PROVIDE ALL CONTROLS AND CONNECTIONS AS REQUIRED TO MAKE SURE IT FUNCTIONS AS REQUIRED. 10 CONTRACTOR SHALL COORDINATE WITH OWNER AND PROVIDE A TIME CLOCK T/C TO CONTROL EXTERIOR LIGHT AND STOREFRONT SIGN. INSTALL JUNCTION BOX AND SWITCH FOR STORE SIGN CIRCUIT AS REQUIRED. 11 AT OWNER'S DISCRETION, ROUTE ALL LIGHTING/SIGN CIRCUITS THROUGH A WATTSTOPPER 8 RELAY PEANUT PANEL LP8S-8-G-115 AND PROVIDE AS-100-W SWITCHES FOR ALL LIGHTING SWITCHES. (FOR LOCAL CONTROL AND TIME OF DAY OVERRIDE ) 12 INSTALL NEW LIGHT SWITCH WITH OCCUPANCY SENSOR. ALL ROOM LIGHTING CONTROLS SHALL COMPLY PER THE FLORIDA BUILDING CODE 2020 ENERGY CONSERVATION CHAPTER 4 SECTION C405. 13 LIGHTING CONTROLS SHALL BE INSTALLED IN COMPLIANCE WITH 2O20 FBC ENERGY CONSERVATION. THIS IS TYPICAL. 14 CONTRACTOR SHALL COORDINATE WITH OWNER, LANDLORD AND INSTALL NEW LOW VOLTAGE EQUIPMENT AS REQUIRED. EXTEND TELEPHONE CONDUIT AND CABLE TO TEL. BD "TTB" IN OFFICE. COORDINATE ALL LOW VOLTAGE REQUIREMENTS WITH OWNER. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL CABLES AND DATA/TEL. OUTLETS. THE TELEPHONE AND LOW VOLTAGE SYSTEMS SHALL BE COMPLETE AND FUNCTIONAL. 15 PROVIDE A MINIMUM 1/2" CONDUIT W/WIRE FROM TELEPHONE OUTLET BACK TO TELEPHONE BOARD LOCATED IN OFFICE AREA. THIS IS TYPICAL FOR ALL TELEPHONE OUTLETS. 16 PROVIDE KEY -LOCK TABS AT THESE CIRCUITS. ROUTE CASH REGISTER CIRCUITS WITH AN ISOLATED GROUND CONDUCTOR. 17 ALL CONDUIT PENETRATIONS THROUGH CASEWORK SHALL BE CLEAN, TIGHT AND SEALED WITH WHITE SILICONE. THIS IS TYPICAL. 18 FURNISH AND INSTALL DUCT SMOKE DETECTORS, RELAY AND REMOTE INDICATOR FOR RTU-1. TIE RELAY INTO DUCT MT'D SMOKE DETECTOR WHICH WHEN ACTIVATED WILL SHUT DOWN THE A/C UNIT FAN AND SIGNAL LANDLORD'S MASTER FIRE ALARM CONT. PANEL, IF REQ'D. PROVIDE CONDUIT, WIRES AND MAKE ALL CONNECTIONS AS REQUIRED. DETERMINE BEST LOCATION OF REMOTE INDICATOR AT SITE. LIGHTING PLAN FIXTURE SCHEDULE SYMBOL DESCRIPTION MANUFAC. CATALOG LAMP MTG. VOLT REMARKS FIXT.S/ TOTAL WATT O 2X4 SUSPENDED LED HIGH BAY LITHONIA IBE L48 12000LM L/LENS MD MVOLT GZ10 40K 80CRI DWH LED (39W) 4000 LUMEN SUSPENDED 120 - PROVIDE ALL REQ'D HARDWARE - (1) EM / NIGHT LIGHT REQ'D AT 1 83 ENTRANCE El 2X2 RECESSED LED TROFFER LITHONIA 2GTL2 LP835 LED (39.6W) 4000 LUMEN RECESSED 120 - PROVIDE ALL REQ'D HARDWARE 1 40 1 PERTRACK TRACK LIGHT WAC LIGHTING H-8010-30-BK-12 LED TRACK 120 HEAD 11 ® PENDANT LED LIGHT FIXTURE COORDINATE WITH OWNER LED PENDANT 120 - PROVIDE ALL REQ'D HARDWARE 1 23 EXISTING EXTERIOR WALL LED WALL 120 1 10 MOUNTED LIGHT FIXTURE EMERGENCY LIGHT SURELITE CC-2 FURNISHED UNIVERSAL 120 90 MINUTE BATT. BACKUP POWER N/A 3 W/UNIT EX EXIT LIGHT ATLITE PNLRU FURNISHED UNIVERSAL 120 90 MINUTE BATT. BACKUP POWER N/A 5 W/UNIT ® CEILING EXHAUST FAN 120 VENTED TO OUTSIDE SEE MECHANICAL DRAWINGS NOTES: 1. ELECTRICAL CONTRACTOR TO INQUIRE ABOUT LOCAL REBATES ON LIGHT FIXTURES. 2. INSTALLATION OF LIGHT FIXTURES SHALL BE ACCORDING TO MANUFACTURER'S RECOMMENDATIONS AND ACCORDING TO CODE REQUIREMENTS. SYMBOLS 2'X4' NIGHT LT (N/L) DUPLEX RECEPTACLE WITH 6 120 V, 20 AMPERE RATING. 6GIFI DUPLEX W/GRND F. INTERRUPTER QUADRUPLEX WITH 120V, 20 A. (QUADRUPLEX W/GRND F. INTERRUPTER WHERE NOTED AS "GFI" O CEILING/WINDOW OUTLETS. ABOVE CEILING. OJUNCTION BOX O1 DISCONNECT SWITCH Q SURFACE MOUNTED POWER PANEL TWO WAY SWITCH TWO WAY SWITCH, WITH OCCUPANCY OS SENSOR (WH) WATER HEATER MANUAL PULL STATION - 270-SPO 42" A.F.F. r� HORN/STROBE-792-7A-006 80" A.F.F. FAN SHUT DOWN RELAY W/ ENCLOSURE-M R-199X-13/C DUCT SMOKE DETECTOR 6264E-001/ 6260A-100/6261-003-6251B-001A ® REMOTE INDICATOR/TEST STATION - 6262A-001 CONCEALED IN WALL, CEILING OR UNDER GROUND CONDUIT RUN CONSISTING OF: Z - GROUND CONDUCTOR III - SMALL LINES INDICATE POWER NON GROUNDED CONDUCTORS. - BIG LINE INDICATES NEUTRAL CONDUCTOR BEFORE PERMITTING OR START OF CONSTRUCTION: 1. TENANT TO ACQUIRE LANDLORD WRITTEN APPROVAL OF ALL PROPOSED ALTERATIONS. 2. CONTRACTOR TO VERIFY ALL EXISTING DIMENSIONS AND ELEVATIONS. 3. CONTRACTOR TO COORDINATE ROUGH WINDOW/ DOOR OPENINGS SIZE W/ MFR SPEC It Lo co C' J Qom' Q-� N Q VN1 w W W z F—I z W �J H V 1 z C U m z F IL U N W 0 Q 0 O c') m a G4 U cd fr E V a E- GCE JOB. N0.21040 COA. NO.29116 MAVEN MARIE, PE. L. # 60166) � z E1.0 GENERAL NOTES: ISSUED FOR: REVIEW 11.01.2021 EXISTING PANEL "A" MCB: 200 A.I.C.: EXISTING PHASE: 3, S/N WIRE: 4 BLDG: VIBES SMOKE SHOP MLO: N/A VOLTS: 120/208 V MTD: RECESSED DESCRIPTION OF LOAD BRKR KVA PH LOAD CIR NO PHASE CI N KVA PH LOAD BRKR DESCRIPTION OF LOAD AMP P 0A 0B 0C A B C 0A OB 0C P AMP H RTU-1 35 3 3.96 1 ■ 2 0.70 1 20 DF & RECEPT. R 3.96 3 ■ 4 0.36 1 20 WINDOW RECEPT. R 3.96 5 ■ 6 SPACE W WATER HEATER 25 212.25 17 ■ 8 0.18 1 20 ROOF RECEPT. R 2.25 9 • 10 0.72 1 20 BACKROOM RECEPT. R L SIGN 20 1 1.20 11 ■ 12 SPACE L INTERIOR LIGHTS 20 110.13 13 ■ 14 0.36 1 20 POS RECEPT. R L INTERIOR LIGHTS 20 1 0.26 15 ■ 16 0.36 1 20 SALES RECEPT. R L DISPLAY LIGHTS 20 1 1.50 17 ■ 18 SPACE L EXISTING EXTERIOR LIGHT 20 110.101 19 ■ 20 0.36 1 20 RESTROOM RECEPT. R I TIME CLOCK 20 11 10.10 21 ■ 22 SPACE L DISPLAY LIGHTS 20 1 1.20 23 124 SPACE 25 ■ 26 27 ■ 28 29 ■ 30 31 ■ 32 33 ■ 34 35 • 36 37 ■ 38 39 ■ 40 41 ■ 42 I TOTAL 1 6.441 6.57 17.86 1 LEGEND L LIGHTING R RECEPTACLE W WATER HEATER I I MISCELLANEOUS H I AIR CONDITION/HEATING LOAD ANALYSIS LOAD VOLT CONNECTED (KVA) FACTOR DEMAND (KVA) LIGHTING 120 4.39 125% 5.49 CONV. OUTLETS 120 3.04 100% 3.04 WATER HEATER 240 4.50 65% 2.93 AIR CONDITION 208 11.88 100% 11.88 MISCELLANEOUS 120 0.10 100% 0.10 OTHERS --- --- 100% --- TOTAL 23.91 23.44 120/208. 30 POWER SUPPLY CALCULATIONS: 1. TOTAL DEMAND LOADS = 23.44 KVA 2. DEMAND CURRENT/O = 65 AMPS @ 120/208V,30 3. EXISTING PANEL "A" = 200 AMP MCB, 120/208V, 30, 4W. 4. EXISTING POWER SUPPLY = 200 AMP, 120/208V, 30, 4W. 11.60 1 1.441 0.00 I TOTAL I OA OB OC TOTAL CONNECTED KVA 8.04 8.01 1 7.86 67 67 1 65 TOTAL CONNECTED AMPS (1)(2) (1) PROVIDE LOCK TAB AT THESE BREAKERS IN "ON" POSITION. (2) ROUTE THIS CIRCUIT WITH ISO. GROUND CONDUCTOR. (3) ROUTE THESE LIGHT CIRCUITS THROUGH TIME CLOCK. I EXTERIOR TENANT SPACE I EXIST. 4-#250 MCM, AL, 1-#4, AL, GRND, 3 2 IN 2" C. FROM UTILITY TRANSFORMER I EXIST. 4-#250 MCM, AL, 1-#4, AL, GRIND, IN 2" C. 7 DAY, 24-HOUR f-El TIMECLOCK I 1 EXIST. D I i I I PANEL EXIST. METER SOCKET, COORDINATE WITH UTILITY M I I J „A" 5 COMPANY TO INSTALL NEW ELECT. I - 200 AMP O METER FOR EXISTING 200A, 120/ I I I 208V, 30, 4 W SERVICE MCB L- r- J I I 120/208V I O L 3PH, 4W I I I I EXIST. GROUNDING-4 0 - I I i RISER DIAG. NOTES: Ol VERIFY EXISTING METER SOCKET IS IN COMPLIANCE WITH RISER DIAGRAM AND N.E.0 APPLICABLE CODE. OVERIFY EXISTING GROUNDING SYSTEM IS IN COMPLIANCE WITH RISER DIAGRAM AND N.E.C. STD. #250 REQUIREMENTS. OVERIFY EXISTING FEEDERS AND CONDUITS ARE IN COMPLIANCE WITH THE RISER DIAGRAM. 4 VERIFY AND REUSE EXISTING PANEL "A" IN COMPLIANCE WITH THE RISER DIAGRAM. ALL BREAKERS IN PANEL SHALL BE BOLTED TYPE. 5 CONTRACTOR SHALL INSTALL A COMPLETE TYPEWRITTEN IDENTIFICATION DIRECTORY CARD FOR ALL MAIN AND BRANCH CIRCUITS IN THE PANEL DOOR (ELECTRICAL PANEL BOX.) EXISTING ELECT. POWER RISER DIAGRAM 1. CONTRACTOR SHALL REVIEW THE SPECIFICATIONS, GENERAL NOTES, KEY NOTES, ELECTRICAL PLANS AND THE LANDLORD DESIGN CRITERIA BEFORE BIDDING AND STARTING ANY CONSTRUCTION WORK. 2. ALL INSTALLATION SHALL COMPLY WITH THE REQUIREMENTS OF THE DESIGN DOCUMENTS, LANDLORD DESIGN CRITERIA AND N.E.C. REQUIREMENTS. 3. CONTRACTOR SHALL VERIFY EXISTING POWER DISTRIBUTION CENTER AND REUSE EXISTING POWER SUPPLY TO THE SPACE IN COMPLIANCE WITH THE RISER DIAGRAM. THIS WILL INCLUDE ELECTRIC METER, FUSED DISCONNECT SWITCH, POWER SUPPLY FEEDER AND POWER PANEL. 4. CONTRACTOR SHALL PROVIDE NEW WIRING AND BREAKERS FOR ALL LOADS AS SHOWN ON PANEL SCHEDULES AS REQUIRED. 5. PULL STRINGS SHALL BE PROVIDED IN ALL EMPTY CONDUIT. FOR TELEPHONE AND LOW VOLTAGE SYSTEM. 6. INTERIOR TELEPHONE AND DATA WIRING SHALL INCLUDE FURNISHING AND INSTALLING ALL TELEPHONE AND DATA JACKS, AND COVER PLATES AS REQUIRED. COORDINATE WITH THE TENANT. 7. LABEL ALL ELECT. EQUIPMENT WITH ENGRAVED BAKELITE NAMEPLATE OR EMBOSSED PLASTIC NAME STRIP. LABEL ALL PANELS AS SHOWN ON THE RISER DIAGRAM. 8. FURNISH NEW TYPE WRITTEN CIRCUIT DIRECTORY CARDS FOR EXISTING PANELS. LIST ALL USED AND SPARE CIRCUITS. 9. CONTRATCOR SHALL PROVIDE NEW DISCONNECT SWITCHES FOR RTU-1 AS DESCRIBED IN KEY NOTE #8. COORDINATE WITH MECHANICAL PLANS AND PROVIDE DUCT SMOKE DETECTOR IF REQUIRED. 10. ALL ELECTRICAL DEVICES AND EQUIPMENT SHALL BE EFFECTIVELY GROUNDED IN ACCORDANCE WITH N.E.C. REQUIREMENTS. ALL BRANCH CIRCUITS SHALL HAVE A SEPARATE GREEN INSULATED GROUND WIRE IN EACH CONDUIT RUN. 11. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL ELECTRICAL CONNECTIONS UNLESS NOTED OTHERWISE. 12. CONTRACTOR SHALL BE RESPONSIBLE FOR COMMUNICATION WITH THE PROPERTY OWNER'S PERSONNEL TO REVIEW CONTRACT DOCUMENTS PRIOR TO INSTALLATION. 13. CONTRACTOR TO SEAL ALL WALL PENETRATIONS IN AN APPROVED MANNER TO INSURE THE FIRE RATING INTEGRITY OF THE INVOLVED AREAS. 14. COORDINATE FINAL INSTALLATION REQUIREMENTS WITH PROPER AUTHORITIES. 15. CONTRACTOR, UPON COMPLETION OF HIS WORK, SHALL BE RESPONSIBLE TO PROVIDE ANY AND ALL CERTIFICATIONS. 16. ALL CONDUIT RUNS ABOVE CEILING SHALL BE PARALLEL OR PERPENDICULAR TO THE COLUMN LINES. 17. ALL CABLES AND WIRES SIZES SHALL COMPLY WITH N.E.C. TABLE 310-16. MINIMUM SIZE OF CONDUCTOR SHALL BE #12 AWG CU. NO. 10 WIRES SHALL BE USED IN PLACE OF #12 FOR CIRCUITS LONGER THAN 75 FEET FROM PANEL TO LOAD. ALUMINUM CONDUCTOR SHALL NOT BE PERMITTED. WIRE INSULATION SHALL BE THHN OR THWN. 18. ALL INTERIOR WIRING SHALL BE CONCEALED AND IN GAL. STEEL OR EMT CONDUITS AND IN COMPLIANCE WITH THE N.E.C. 19. CONTRACTOR MAY USE FLEXIBLE CONDUIT FROM JUNCTION BOX TO THE LIGHTING FIXTURE, BETWEEN LIGHTING FIXTURES, AND TO OTHER DEVICES PROVIDED THE LENGTH OF THE FLEXIBLE CONDUIT IS NOT MORE THAN 6 FEET. 20. BX, ROMAX, MC OR ANY OTHER ARMORED OR METAL -CLAD WIRING SHALL NOT BE PERMITTED. BEFORE PERMITTING OR START OF CONSTRUCTION: 1. TENANT TO ACQUIRE LANDLORD WRITTEN APPROVAL OF ALL PROPOSED ALTERATIONS. 2. CONTRACTOR TO VERIFY ALL EXISTING DIMENSIONS AND ELEVATIONS. 3. CONTRACTOR TO COORDINATE ROUGH WINDOW/ DOOR OPENINGS SIZE W/ MFR SPEC: c m Z F a U N Ld 0 11111111 U) w J D 0 Lu U) J W z Q J Q _U U J w Lo 1'--o � U co I I) �z cta w I d r- O �a m 0 w z W z w U Q 1.4 ti ti O E+ V1 O z P., O E- U a; 1.4 a � m w O e� I._4 o W IL co JOB. N0.21040 GICIE COA. NO.29116 MAZEN IWARIE, PE. L. P 60166) r 1J E2.0 ISSUED FOR: REVIEW 11.01.2021 m I ELECTRICAL SPECIFICATIONS AND INSTRUCTIONS FOR INSTALLATION WORK 1.0 GENERAL 1.1 BIDDERS QUALIFICATIONS AND INSTRUCTIONS: 1.1.1 QUALIFICATIONS: THE BIDDERS SHALL BE QUALIFIED, EXPERIENCED, AND LICENSED ELECTRICAL CONTRACTORS. THEY MUST BE FAMILIAR WITH ALL FEDERAL, STATE, AND LOCAL LAWS, ORDINANCES, RULES, AND REGULATIONS THAT MAY, IN ANY MANNER, AFFECT THE TASK. 1.1.2 BIDDING INSTRUCTIONS: BEFORE SUBMITTING THE BID, THE BIDDERS MUST REVIEW THE TENANT INFORMATION AND CRITERIA MANUAL, SPECIFICATIONS, PLANS, DRAWINGS, AND ALL OTHER CONDITIONS AND REQUIREMENTS THAT MAY, IN ANY MANNER AFFECT THE WORK UNDER CONTRACT. THEY MUST VISIT THE SITE OF THE PROPOSED PROJECT TO FAMILIARIZE THEMSELVES WITH THE LOCAL CONDITIONS, FIRE RATING REQUIREMENTS, AND THE NATURE OF THE PROJECT. THE PRICING SHALL BE BASED ON THESE SPECIFICATIONS AND THE MATERIALS SHOWN ON THE DRAWINGS. SUBMISSION OF THE BIDS SHALL BE CONSIDERED AS THE EVIDENCE THAT THE BIDDER IS FAMILIARIZED TO ALL THE FACETS OF THE SPECIFIED PROJECT. CONTRACTOR SHALL USE APPLICABLE SECTIONS OF THIS SPEC. 1.1.3 EXCEPTIONS: ANY EXCEPTIONS, OMISSIONS, DISCREPANCIES, AND DOUBTS REGARDING PLANS, DRAWINGS, AND SPECIFICATIONS, IF ANY, SHALL BE COMMUNICATED PROMPTLY IN WRITING TO THE ARCHITECT OR TO THE ENGINEER FOR THEIR REVIEW AND RESPONSE BACK BEFORE THE BID SUBMISSION DATE. NO ORAL COMMUNICATION REGARDING THE EXCEPTIONS OR CHANGES SHALL BE ACCEPTED. BIDDERS SHALL BE NOTIFIED OF ANY CHANGES, IF MADE, DUE TO THE ACCEPTANCE OF EXCEPTIONS BEFORE THE BID SUBMITTAL DATE. 1.1.4 MATERIAL TAKE OFF: ALL MATERIAL TAKE OFFS, OTHER THAN THE EXISTING DEVICES, SHALL BE MADE USING THE LIGHT & POWER WIRING AND CONDUIT DRAWINGS AND THEIR ASSOCIATED REFERENCES INCLUDING THE SPECIFICATIONS OF THIS PROJECT ON THIS DRAWING. ALL LIGHTING MATERIALS INCLUDING TRANSFORMER, PANELS, FIXTURES, SWITCHES, RECEPTACLES, WIRES AND RACEWAYS, ETC. SHALL BE PURCHASED BY THE CONTRACTORS PER SECTION NO. 2, UNLESS NOTED OTHERWISE. 1.1.5 BID PRICE: THE BID PRICE SHALL INCLUDE LABOR AND MATERIAL COSTS, NECESSARY INSURANCE COSTS AND PERMITS FEES AS REQUIRED TO INSTALL THE COMPLETE ELECTRICAL SYSTEM IN COMPLIANCE WITH THE DESIGN REQUIREMENTS OF THIS PROJECT. 1.1.6 SUCCESSFUL BIDDER: THE SUCCESSFUL BIDDER WILL BE REFERENCED AS THE CONTRACTOR FROM THIS POINT ONWARDS THROUGHOUT THE REST OF THE SPECIFICATION. 1.2 THE ELECTRICAL CONTRACTOR REQUIREMENTS AND INSTRUCTIONS: 1.2.1 THE CONTRACTOR SHALL USE EXPERIENCED AND SKILLED PERSONS TO PERFORM ALL THE ELECTRICAL INSTALLATION WORK UNDER THE CONSTANT SUPERVISION OF LICENSED ELECTRICIANS AND/OR LICENSED JOURNEYMAN ELECTRICIANS. 1.2.2 THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL REQUIRED PERMITS, PAYING ALL FEES, AND PROVIDING ALL NECESSARY INSPECTIONS INCIDENTAL TO THE ELECTRICAL PORTION OF THE WORK. 1.2.3 THE CONTRACTOR SHALL BE RESPONSIBLE FOR CARRYING NECESSARY INSURANCE AS REQUIRED BY LAW TO PROTECT EMPLOYEES, OTHER PERSONS, EQUIPMENT, AND MATERIAL. 1.2.4 THE INSTALLATION WORK SHALL COMPLY WITH ALL APPLICABLE STATE, COUNTY, AND LOCAL BUILDING CODES. APPLICABLE CODES, AS A MINIMUM, WILL INCLUDE THE LATEST EDITION OF THE FOLLOWING. THESE WILL BE CONSIDERED PART OF THE SPECIFICATION OF THIS PROJECT. A) BUILDING CODE OF THE APPLICABLE CITY AND COUNTY. B) NATIONAL ELECTRIC CODE NFPA 70, 2017 C) LIFE SAFETY CODE NFPA 101, 2018 D) S.B.C.C.I. LATEST EDITION. 1.2.5 IN CASE OF SUBSTITUTIONS THE CONTRACTOR SHALL PROVIDE A WRITTEN REQUEST TO THE ARCHITECT FOR HIS REVIEW . THE CONTRACTOR SHALL IDENTIFY CLEARLY THE DIFFERENCE BETWEEN THE SPECIFIED ITEMS AND THE SUBSTITUTE ITEMS, INCLUDING THE ECONOMIC IMPACT ON THE PROJECT. THE SUBSTITUTE ITEM SHALL NOT BE ORDERED OR USED UNLESS APPROVED BY THE ARCHITECT AND/OR BY THE OWNER IN WRITING. 1.2.6 THE CONTRACTOR SHALL SUBMIT FIVE SETS OF SHOP DRAWINGS FOR SPECIFIED PRODUCTS AT ONE TIME WITHIN THIRTY (30) DAYS FROM THE OFFICIAL NOTICE TO PROCEED. SHOP DRAWING SUBMITTAL SHALL BE MADE FOR THE FOLLOWING MATERIALS AND SYSTEMS: A. LIGHTING FIXTURES, DIMMERS, LAMPS, AND SAFETY SWITCHES. B. TRANSFORMERS, SWITCH BOARDS, DISTRIBUTION PANELS, DISCONNECTS, AND WIREWAYS IF PURCHASED NEW. C. METER CENTERS, CIRCUIT BREAKERS, FUSES, MOTOR STARTERS IF PURCHASED FOR THIS PROJECT. D. TIME CLOCK AND OTHER DEVICES. E) SCHEMATIC DIAGRAMS FOR THE ABOVE ITEMS. 1.2.7 THE CONTRACTOR SHALL PROVIDE FOLLOWING DOCUMENTS BEFORE THE CLOSING OF THE PROJECT AND PRIOR TO THE FINAL PAYMENT: A. ONE YEAR WRITTEN WARRANTY FOR ANY DEFECT IN WORKMANSHIP, MATERIAL, AND EQUIPMENT. B. TWO SETS OF MANUFACTURER'S OPERATIONAL AND MAINTENANCE MANUALS IF APPLICABLE. C. MANUFACTURER'S WARRANTIES AND WARRANTY CERTIFICATES. D. TWO SETS OF REPRODUCIBLE OR RED MARKED UP PRINTS OF "AS -BUILT" DRAWINGS, ONE FOR THE ARCHITECT AND ONE FOR THE OWNER OF THE PROJECT. 1.2.8 THE CONTRACTOR SHALL BE RESPONSIBLE TO PROVIDE THE NECESSARY TEMPORARY ELECTRICAL POWER, AT HIS EXPENSE, AS REQUIRED BY HIS TRADE AND BY THE GENERAL CONTRACTOR. 1.2.9 THE CONTRACTOR SHALL MAKE SURE ON A DAILY BASIS THAT ALL UNNECESSARY MATERIAL AND TRASH CONTRIBUTED BY HIS TRADE ARE REMOVED. 1.2.10 THE CONTRACTOR SHALL CONCEALED ALL THE CONDUIT IN THE FINISHED AREAS. 2.0 PRODUCTS: 2.1 GENERAL: THE ELECTRICAL CONTRACTOR SHALL PURCHASE AND USE ALL "NEW" MATERIAL AS SPECIFIED AND SHOWN ON THE ELECTRICAL PLAN OF THIS PROJECT. ALL THE MATERIAL SHALL BE FREE FROM DEFECTS AND SHALL CARRY A "UL" LABEL. 2.2 CONDUCTORS: T CONDUCTORS HALL BE UNCOATED COPPER OF 98% CONDUCTIVITY 6 VOLT DAL ALL INSULATED UCTO S S O 00 O C, U RATED, TYPE THHN/THWN AS NECESSARY TO MEET THE DESIGN REQUIREMENTS AND THE APPLICABLE CODES. THW (FOR # 4 AWG AND LARGER) AND THERMO PLASTIC WIRES RATED FOR 75 DEGREES CENTIGRADE OPERATIONS IN WET AND DRY LOCATIONS AND 90 DEGREES CENTIGRADE WITHIN ELECTRIC DISCHARGE LIGHTING EQUIPMENT MAY BE USED. CONDUCTORS NUMBER # 10 AWG AND LOWER SHALL BE SOLID COPPER AND #8 AWG AND ABOVE SHALL BE STRANDED COPPER. THE MINIMUM SIZE OF WIRE SHALL BE # 12 AWG FOR 20 AMP BREAKER, # 10 AWG FOR 30 AMP BREAKER, # 8 AWG FOR 40 AMP BREAKER. 2.3 CABLE: SIGNAL CABLES, IF USED, SHALL BE COPPER AND SHALL MEET ALL UL AND N.E.C. CODE REQUIREMENTS. METAL CLAD (TYPE MC), ARMORED (TYPE AC) AND NOW METALLIC (NM) CABLES SHALL NOT BE USED. ALL CABLE ASSEMBLIES SHALL CONTAIN COPPER GROUND CONDUCTOR. 2.4 CONDUITS: THE CONDUITS SHALL BE ELECTRICAL METALLIC TUBING (EMT) AND HOT DIPPED GALVANIZED STANDARD STEEL AS MANUFACTURED BY WHEATLAND TUBE COMPANY OR EQUIVALENT. 2.5 OUTLET BOXES AND FITTINGS: OUTLET BOXES, FITTING CLAMPS AND HANGERS ETC. SHALL BE GALVANIZED STEEL, RUST RESISTANT AND COMPATIBLE WITH THE RACEWAY. OUTLET BOXES FOR FIXTURES, SWITCHES, AND RECEPTACLES SHALL HAVE SMOOTH ROUND EDGES AND SHALL BE WITH COVER PLATES. BOXES SHALL BE "STEEL CITY" OR EQUIVALENT. FITTINGS FOR EMT CONDUITS SHALL BE COMPRESSION TYPE. NO SET SCREW WILL BE USED. UNUSED HOLES SHALL BE COVERED WITH APPROVED INSERT CAPS. 2.6 SWITCHES AND DIMMERS: SWITCHES AND DIMMERS SHALL BE TOTALLY ENCLOSED, RATED AT 120/277 VOLTS AC, 20 AMPS, 2000 WATTS WITH GRAY TOGGLE AND DEVICE PLATE. THESE SHALL BE QUIET OPERATION, COMMERCIAL GRADE AS MANUFACTURED BY LEVITON, LUTRON OR EQUIVALENT. PLATES SHALL MATCH THE SWITCHES. FURNISH IN GANGS AS NECESSARY. 2.7 RECEPTACLES: RECEPTACLE SHALL BE COMMERCIAL GRADE, 125 VOLTS AC, AND 20 AMPERE RATING WITH GROUNDED POLE AND TWO CIRCUIT OPTION, AS MANUFACTURED BY LEVITON OR EQUIVALENT. PLATES SHALL MATCH THE RECEPTACLES. FURNISH IN GANGS AS NECESSARY. 2.8 DEVICE PLATES: PROVIDE DEVICE PLATE FOR EACH AND EVERY OUTLET BOX. FURNISH IN GANGS AS NECESSARY. PLATES AND SCREWS SHALL BE GRAY UNLESS THE OWNER PREFERS SOME OTHER COLOR, AND SHALL BE OF THE SAME MANUFACTURER AS OF THE DEVICES. 2.9 BALLASTS: BALLASTS FOR FLUORESCENT FIXTURES SHALL BE RAPID START, SYLVANIA ELECTRONIC ENERGY SAVING, HIGH POWER FACTOR AND SHALL BE CLASS "P," CBM, TITLE 24 CERTIFIED WITH INTERNAL THERMAL PROTECTOR WITH AUTOMATIC RESET AND CLASS "A" SOUND RATING NOISE LEVELS LESS THAN 30 dB MAXIMUM. BALLASTS SHALL BE MANUFACTURED BY SYLVANIA AS SHOWN ON THE LIGHTING SCHEDULE OR EQUAL EQUAL AND SHALL SHALL BE GUARANTEED AT LEAST FOR FIVE (5) YEARS OF OPERATION AFTER THE ACCEPTANCE. THE BALLAST MODEL NUMBER SHALL BE "2 OR 4 LAMP PSX-SYL Xtreme AS REQUIRED". 2.10 LAMPS: LAMPS SHALL BE MANUFACTURED BY SYLVANIA MODEL # SYL "F028/841XP/SS/ECO OR EQUIVALENT. ALL LAMPS SHALL BE GUARANTEED FOR AT- LEAST 4 YEARS OF OPERATION AFTER THE ACCEPTANCE. 2.11 LIGHTING DEVICES: ALL LIGHTING FIXTURES, EMERGENCY & EXIT LIGHTS SHALL BE AS LISTED ON THE LIGHT FIXTURE SCHEDULE; HOWEVER BEFORE PURCHASING ANY LIGHT FIXTURES, SUBMIT FIXTURE. CUT SHEETS FOR THE ARCHITECT AND THE OWNER'S APPROVAL. 2.12 TIME CLOCK OR TIME SWITCH: TIME CLOCK SHALL BE ELECTRO- MECHANICAL 24 HOURS SEVEN DAYS TYPE WITH RESERVE POWER AND CONTACTS RATED 40 A. 4 PST AND N.E.M.A. TYPE 1 OR 3R ENCLOSURE. IT SHALL BE SELF POWERED BY A SELF STARTING SYNCHRONOUS MOTOR WITH MINIMUM 16 HR SPRING DRIVEN RESERVE POWER AND A DAY OMITTING DEVICE. TIME CLOCK SHALL BE PARAGON 7007-0, TORK "W" SERIES, OR APPROVED EQUAL. 2.13 GUARANTEE: ALL ELECTRICAL EQUIPMENT, MATERIAL AND WORKMANSHIP SHALL BE GUARANTEED FOR A PERIOD OF ONE (1) YEAR FROM THE DATE OF ACCEPTANCE. 3.0 INSTALLATION INSTRUCTIONS: 3.1 GENERAL: THE PLAN LOCATION OF LIGHTING FIXTURES, JUNCTION BOXES, CONVENIENCE OUTLETS, AND PANEL BOARDS ARE APPROXIMATE UNLESS DIMENSIONED AND ARE TO BE ADJUSTED BY THE CONTRACTOR AS REQUIRED IN THE AREAS WHERE CEILING GRID AND OTHER OBSTRUCTIONS DETERMINE FIXTURE LOCATIONS. THE CONTRACTOR SHALL COORDINATE WITH OTHER ARCHITECTURAL, MECHANICAL AND OTHER SYSTEMS TO AVOID INTERFERENCE. ALL CUTTING AND CONSEQUENT REPAIRS IN CONJUNCTION WITH THE WORK SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. BEAMS OR OTHER STRUCTURAL COMPONENT SHALL NOT BE CUT WITHOUT THE KNOWLEDGE AND WRITTEN CONSENT OF THE ARCHITECT. 3.2 THE CONTRACTOR SHALL PROVIDE ALL NECESSARY MATERIALS, LABOR, TRANSPORTATION, RIGGING & HOISTING, TOOLS, AND STORAGE, ETC, FOR ALL WORK INDICATED AND REQUIRED FOR COMPLETE INSTALLATION. 3.3 THE ELECTRICAL WORK SHALL BE EXECUTED IN ACCORDANCE WITH ALL APPLICABLE CODES AND SHALL INCLUDE COMPLETE TESTING OF ALL EQUIPMENT AND WIRING. WORKMANSHIP SHALL BE THE HIGHEST QUALITY AS ESTABLISHED BY TRADE STANDARD. 3.4 THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING NECESSARY PERMITS AND COMMUNICATIONS WITH THE LOCAL BUILDING DEPARTMENT AND INSPECTION PERSONNEL TO REVIEW CONTRACT DOCUMENTS PRIOR TO INSTALLATION. 3.5 OWNER WILL NOT BE HELD RESPONSIBLE FOR FIELD CHANGES THAT ARISE FROM CONTRACTOR'S ERROR OR OMISSION OF MATERIALS OR WORKMANSHIP IN WORK PERFORMANCE. 3.6 THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OF ALL UTILITIES PLACEMENT, AS IDENTIFIED ON THE RISER DIAGRAM, AND LOCATION OF THE ELECTRICAL SERVICE EQUIPMENT. THE PAY ALL NECESSARY CHARGES ASSOCIATED WITH INSTALLATION OF ALL UTILITIES CONTRACTOR SHALLA S O TO THE POWER COMPANY PRIOR TO THE CONSTRUCTION. A LETTER SHALL BE PROVIDED FROM THE POWER COMPANY THAT ALL THE CHARGES HAVE BEEN PAID IN FULL. 3.7 NECESSARY AND OBVIOUSLY REQUIRED, ELECTRICAL ITEMS THAT ARE NOT SHOWN ON THE DRAWINGS, SHALL NOT RELIEVE THE CONTRACTOR OF HIS RESPONSIBILITIES TO INSTALL A COMPLETE AND SAFE ELECTRICAL SYSTEM. 3.8 THE ELECTRICAL CONTRACTOR SHALL FOLLOW THE SAME COLOR CODE IDENTIFICATION FOR EACH PHASE THROUGHOUT THE SYSTEM FROM SERVICE SWITCH OR TRANSFORMER THROUGH ALL BRANCH CIRCUITS. 3.9 ALL SLAB OR ROOF PENETRATIONS SHALL BE MADE WITH APPROVED FIRE RATED SMOKE BARRIER FITTINGS. PROVIDE ACCESSORIES (PITCH POCKETS, SLEEVES, ETC.) AS REQUIRED. 3.10 JUNCTION BOXES FOR NEON SIGN LIGHTS, SWITCHES, LIGHTING FIXTURES, RECEPTACLES AND FOR PULLING WIRES SHALL BE AS APPROXIMATE AS SHOWN ON THE PLANS BUT EXACT LOCATIONS SHALL BE GOVERNED BY THE ARCHITECTURAL PLANS. 3.11 ALL OUTLET BOXES SHALL HAVE SQUARE CUT CORNERS. AIR SPACE GREATER THAN 1/8" AROUND OUTLET BOXES, AND ADJACENT DRYWALL WILL NOT BE PERMITTED. THE CONTRACTOR SHALL COORDINATE WITH DRYWALL INSTALLER PRIOR TO INSTALLATION. CAULK AROUND BOXES TO ELIMINATE STEEL OUTLET. 3.12 LIGHTING SWITCHES AND CONVENIENCE RECEPTACLES SHALL BE FLUSH MOUNTED IN SECTIONAL SWITCH BOXES WITH MATCHING COVER PLATES UNLESS NOTED OTHERWISE. 3.13 THE MOUNTING ARRANGEMENT OF EACH FIXTURE WILL BE DETERMINED BY THE CONTRACTOR EXCEPT WHERE THE MANUFACTURER HAS GIVEN SPECIFIC MOUNTING INSTRUCTIONS. 3.14 THE CONTRACTOR SHALL FURNISH AND INSTALL ALL LUMINARIES, DEVICES, AND EQUIPMENT AS SPECIFIED AND SHOWN ON THE PLAN DIAGRAMS. PROVIDE ALL CABLES, CONDUCTORS, CONDUITS, AND CONNECTIONS AS REQUIRED TO PROVIDE COMPLETE AND OPERATIONAL ELECTRICAL AND MECHANICAL SYSTEMS. ALL CONDUITS SHALL BE RUN CONCEALED IN FINISHED AREAS. 3.15 INDIVIDUAL BREAKERS WILL SUPPLY ELECTRICAL POWER TO INDIVIDUAL SIGN OR NEON LIGHT CIRCUITS. NEON TRANSFORMER EQUIPMENT IS TO BE CONCEALED ABOVE ADJACENT COLUMN ENCLOSURE OR TO BE INSTALLED AS SHOWN ON ARCHITECTURAL DRAWINGS. 3.16 ALL JOINTS IN CONDUIT AND RACEWAY SHALL BE MADE TIGHT AND BENDS SHALL BE MADE OVER LONG RADIUS WHERE ENTERING A CABINET AND JUNCTION BOX. THE CONTRACTOR SHALL SUPPORT ALL CONDUIT AND RACEWAYS SECURELY FROM JOISTS AND/OR BEAMS (TIE WIRES ARE NOT ACCEPTABLE). THE CONTRACTOR SHALL VERIFY ALL RACEWAY SIZES IN ACCORDANCE WITH THE N.E.C. CODE. NO CONDUIT SHALL CARRY MORE THAN THREE (3) CURRENT CARRYING CONDUCTORS. NOTE: ALL JOB CUT THREADS SHALL BE COATED WITH RUST RESISTANT ZINC CHROMATE FOR THIN WALL EMT. 3.17 LIGHTING CONDUITS SHALL BE SUPPORTED AT EVERY 8 FEET. 3.18 MOUNTING HEIGHT OF LIGHTING EQUIPMENT, UNLESS NOTED OTHERWISE ON ARCHITECTURAL PLANS SHALL BE APPROXIMATELY AS FOLLOWS: A. LIGHTING SWITCHES CENTERLINE 4 FEET ABOVE A.F.F B. CONVENIENCE OUTLETS CENTERLINE 1 FEET, 6 INCHES A.F.F C. LIGHTING & POWER PANELS TOP 6 FEET, 6 INCHES ABOVE A.F.F D. EMERGENCY LIGHT FIXTURES W ABOVE A.F.F TO BOTTOM OF THE UNIT. 3.19 ELECTRICAL RACEWAYS AND SHALL BE SIZED IN ACCORDANCE WITH NATIONAL ELECTRIC CODE (N.E.C.), ARTICLE 250. ALL BRANCH CIRCUITS SHALL HAVE A SEPARATE GREEN INSULATED GROUND WIRE IN EACH CONDUIT RUN. ISOLATED GROUND CONDUCTORS SHALL BE ROUTED TO THOSE CIRCUITS WHICH NEED ISOLATED GROUND SPECIALLY FOR COMPUTERS AND CASH REGISTERS. 3.20 THE CONTRACTOR SHALL PROVIDE LIGHTNING PROTECTION VOLTAGE SURGE PROTECTOR FOR ALL SERVICE PHASE CONDUCTORS TO GROUND (IF IT IS NOT ALREADY THERE IN CASE OF RENOVATIONS). DEVICE SHALL BE APT TE 400 OR APPROVED EQUIVALENT. 3.21 LUMINARIES SHALL BE AS SPECIFIED IN THE "LIGHTING FIXTURE SCHEDULE". ALL RECESSED AND LAY -IN FIXTURES SHALL BE SUPPORTED FROM THE FOUR CORNERS WITH SUPPORTS CAPABLE OF CARRYING TWICE THE WEIGHT OF THE FIXTURE. ALL SUPPORTS SHALL BE ATTACHED TO THE JOISTS AND/OR BEAMS, NO LIGHTING FIXTURE SHALL BE INSTALLED WITHIN 2 FEET OF ANY SPRINKLER HEAD. 3.22 THE CONTRACTOR SHALL INSTALL ALL TELEPHONE JACKS AND WIRING FROM THE MAIN TELEPHONE TERMINAL BOARD TO THE FINAL TELEPHONE OUTLETS. WIRING SHALL BE INSTALLED IN A MINIMUM 1/2 INCH CONDUIT. 3.23 THE CONTRACTOR SHALL COORDINATE WITH THE FIRE PROTECTION CONTRACTOR AND SHALL MAKE ALL NECESSARY CONNECTIONS BETWEEN DUCT SMOKE DETECTORS AND HVAC UNITS. 3.24 ALL JUNCTION BOXES SHALL BE ACCESSIBLE FROM BELOW. OTHERWISE, CONTRACTOR SHALL PROVIDE ACCESS PANEL AT ALL JUNCTION BOX LOCATIONS AND SMOKE DETECTORS. 3.25 IF NOT ALREADY EXISTING, THE CONTRACTOR SHALL FURNISH ALL THE NECESSARY DISCONNECT SWITCHES, RELAY BOXES, AND CONTROL BOXES AS REQUIRED AND RECOMMENDED BY THE HVAC MANUFACTURER FOR THE HVAC UNIT AND WATER HEATER. THE ELECTRICAL CONTRACTOR SHALL COORDINATE WITH THE MECHANICAL CONTRACTOR AND MAKE ALL NECESSARY CONNECTIONS TO MAKE THE HVAC SYSTEM FUNCTIONAL. 3.26 A PLASTIC COVERED TYPE WRITTEN IDENTIFICATION CARD FOR ALL MAIN AND BRANCH CIRCUITS INCLUDING SPARES SHALL BE POSTED AT THE INSIDE OF THE PANEL DOOR. 3.27 LOCK -ON DEVICES ON PANEL CIRCUIT BREAKERS FOR NIGHT, EXIT AND EMERGENCY LIGHTING CIRCUITS SHALL BE PROVIDED AND THE SHALL BE GIVEN TO THE OWNER. 3.28 LOW VOLTAGE WIRING LOCATED ABOVE THE CEILING SHALL BE PLENUM RATED OR INSTALLED IN METAL CONDUIT. 4.0 TRANSFORMER AND PANEL BOARD SPECIFICATIONS : THIS SECTION SHALL APPLY TO THE NEW TRANSFORMER, PANEL BOARDS, CIRCUIT BREAKERS, PANEL BOXES & TRIMS, DISCONNECT SWITCHES, AND FUSES. 4.1 PANEL BOARDS: PANEL BOARDS SHALL BE GENERAL PURPOSE N.E.M.A. TYPE 1 EN R TYPE R O 3 ENCLOSUR ES SUITABLE FOR SPECIFIED INDOOR OR OUT DOOR LOCATIONS AND AND FLUSH OR SURFACE MOUNTING APPLICATIONS AS INDICATED ON THE PANEL SCHEDULE. PANEL BOARDS AND THE INTERNAL COMPONENTS SHALL BE RATED TO PERFORM THEIR FUNCTIONS CONTINUOUSLY AT 400C AMBIENT AND 50% RELATIVE HUMIDITY. BUSSES, TERMINALS, AND LUGS SHALL BE RATED AND CAPABLE TO FUNCTION CONTINUOUSLY AT 75 DEGREES CENTIGRADE. PANEL BOARDS SHALL BE AS MANUFACTURED BY WESTINGHOUSE ELECTRIC CORP., GENERAL ELECTRIC, SQUARE 'D', CHALLENGER, OR APPROVED EQUAL. A NAMEPLATE LISTING PANEL NUMBER, TYPE, MANUFACTURER'S NAME, NUMBER OF PROTECTIVE AND SWITCHING DEVICES, VOLTAGE, CURRENT, PHASE AND AIC RATINGS SHALL BE PROVIDED. BRANCH CIRCUITS SHALL BE ARRANGED USING DOUBLE ROW CONSTRUCTION. ALL INTERIORS SHALL BE COMPLETELY FACTORY ASSEMBLED WITH SWITCHING AND PROTECTIVE DEVICES, WIRE CONNECTORS, ETC. ALL WIRE CONNECTORS, EXCEPT SCREW TERMINALS, SHALL BE OF THE ANTI -TURN SOLDERLESS TYPE AND ALL SHALL BE SUITABLE FOR COPPER WIRE OF THE SIZES INDICATED ON DRAWINGS OR IN THE PANEL SCHEDULES AND CONTINUOUSLY FUNCTIONING AT 75 DEGREE CENTIGRADE. ALL BREAKERS, SIZED AS SHOWN ON PANEL SCHEDULE, SHALL BE BOLT -ON BREAKERS. INTERIORS SHALL BE SO DESIGNED THAT SWITCHING AND PROTECTIVE DEVICES CAN BE REPLACED WITHOUT DISTURBING ADJACENT UNITS AND WITHOUT REMOVING THE MAIN BUS CONNECTORS AND SHALL BE SO DESIGNED THAT CIRCUITS MAY BE CHANGED WITHOUT MACHINING, DRILLING, OR TAPPING. BUS BARS FOR THE MAINS SHALL BE OF COPPER AND SIZED IN ACCORDANCE WITH UNDERWRITERS' LABORATORIES STANDARDS. UNLESS NOTED OTHERWISE, FULL SIZE NEUTRAL BARS SHALL BE INCLUDED. BUS BAR TAPS FOR PANELS WITH SINGLE POLE BRANCHES SHALL BE ARRANGED FOR SEQUENCE PHASING OF THE BRANCH CIRCUIT DEVICES. THE SHORT CIRCUIT RATING OF THE ASSEMBLED PANEL BOARD SHALL BE IN ACCORDANCE WITH UL. INC. STANDARDS AND THEIR TEST VERIFICATION. PHASE BUSSING SHALL BE FULL HEIGHT WITHOUT REDUCTION. CROSS AND CENTER CONNECTORS SHALL BE COPPER. NEUTRAL AND GROUND BUSSING SHALL HAVE SUITABLE LUGS FOR OUTGOING FEEDERS REQUIRING A NEUTRAL AND GROUND CONNECTIONS. SPACES FOR FUTURE SWITCHING AND PROTECTIVE DEVICES ON LIGHTING AND APPLIANCE DISTRIBUTION PANELS SHALL BE BUSSED FOR THE MAXIMUM DEVICE THAT CAN BE FITTED INTO THEM. PROVIDE BLANK FILLER PLATES IN THE EMPTY SPACES. 4.2 CIRCUIT BREAKER: THE CIRCUIT BREAKERS ARE TO BE INDUSTRIAL MOLDED CASE BOLT ON TYPE, STANDARD THERMAL, MAGNETIC, WITH TRIP FREE MECHANISM, THREE POSITION HANDLES INDICATING "ON" "OFF" AND "TRIPPED" CONDITION. EACH POLE SHALL PROVIDE INVERSE TIME DELAY AND INSTANTANEOUS CIRCUIT PROTECTION. THE BREAKER RATING AND CONFIGURATION SHALL BE AS INDICATED ON THE PANEL BOARD SCHEDULE. ALL MULTI POLE BREAKERS SHALL HAVE AN INTERNAL COMMON TRIP. ALL BREAKER LUGS SHALL BE SUITABLE TO WITHSTAND 75 DEGREE CENTIGRADE WITHOUT MALFUNCTIONING. 4.3 PANEL TRIM: HINGED DOORS IN PANEL TRIMS SHALL COVER ALL SWITCHING DEVICE HANDLES AND SHALL CONFORM TO THE FOLLOWING REQUIREMENTS: 1. DOORS SHALL NOT UNCOVER ANY LIVE PARTS WHILE MAKING SWITCHING DEVICE HANDLES ACCESSIBLE. 2. DOORS SHALL HAVE FLUSH -TYPE CYLINDER LOCK AND CATCH, EXCEPT THAT DOORS OVER 48" IN HEIGHT SHALL HAVE AUXILIARY FASTENERS AT TOP AND BOTTOM OF DOOR IN ADDITION TO FLUSH -TYPE CYLINDER LOCK AND CATCH. DOOR HINGES SHALL BE CONCEALED. ALL LOCKS SHALL BE KEYED ALIKE. DIRECTORY FRAME AND CARD HAVING A TRANSPARENT COVER SHALL BE FURNISHED ON EACH DOOR. THE TRIMS SHALL BE FABRICATED FROM CODE GAUGE SHEET STEEL. ALL EXTERIOR AND INTERIOR STEEL SURFACES OF THE PANEL BOARDS SHALL BE PROPERLY CLEANED PRIMED AND PAINTED IN ACCORDANCE WITH THE MANUFACTURER'S STANDARD SPECIFICATIONS AND COLOR. TRIMS FOR FLUSH MOUNT PANELS SHALL OVERLAP THE BOX BY AT LEAST 3/4" ALL AROUND. SURFACE MOUNT PANELS TRIMS SHALL HAVE THE SAME WIDTH AND HEIGHT AS OF THE BOX. TRIMS SHALL BE MOUNTABLE BY A SCREW DRIVER WITHOUT THE NEED FOR SPECIAL TOOLS. 4.4 PANEL BOXES: BOXES SHALL BE MADE FROM UNPAINTED GALVANIZED CODE GAUGE STEEL HAVING MULTIPLE KNOCKOUTS ON THE TOP AND THE BOTTOM EXCEPT WHERE NOTED OTHERWISE. BOXES SHALL BE OF SUFFICIENT SIZE TO PROVIDE A MINIMUM GUTTER SPACE OF 4" ON ALL SIDES. WHERE FEEDER CABLES SUPPLYING THE MAINS OF A PANEL ARE CARRIED THROUGH ITS BOX TO SUPPLY OTHER ELECTRICAL EQUIPMENT, THE BOX SHALL BE SO SIZED AS TO INCLUDE THIS WIRING SPACE. THIS WIRING SPACE SHALL BE IN ADDITION TO THE MINIMUM GUTTER SPACE SPECIFIED ABOVE AND THE LIMITING WIDTH MAY BE INCREASED ACCORDINGLY. AT LEAST FOUR (4) INTERIOR MOUNTING STUDS SHALL BE PROVIDED. ALL UNUSED HOLES IN THE BOXES SHALL BE PLUGGED WITH APPROVED INSERT CAPS. BOXES SHALL BE "STEEL CITY" OR EQUAL. 4.5 DISCONNECT SWITCHES: THE CONTRACTOR SHALL INSTALL N.E.M.A. TYPE 1 DISC. SWITCHES FOR INDOOR AND N.E.M.A. TYPE 3R DISC. SWITCHES FOR OUT DOOR APPLICATIONS. ALL DISCONNECT SWITCHES FOR SERVICE CONDUCTOR ENTRANCES SHALL BE RATED AT LEAST 100K AIC. DISCONNECT SWITCHES FOR MOTOR CIRCUIT AND FIXED LOAD (SUCH AS HVAC EQUIPMENT, AND WATER HEATER ETC.) CIRCUITS SHALL BE FUSIBLE OR NON FUSIBLE AS SHOWN ON THE DRAWINGS OR REQUIRED BY THE MANUFACTURER. 4.6 FUSE: THE CONTRACTOR SHALL USE DUAL ELEMENT, TIME DELAY CURRENT LIMITING, 100,000 AMP AIC RATED, CLASS RK-1 FUSES WHEN PROTECTING PANEL BOARDS AND TRANSFORMERS AND 100,000 AMP AIC RATED CLASS RK-5 FUSES WHEN PROTECTING MOTORS UNLESS NOTED OTHERWISE OR REQUIRED DIFFERENTLY BY THE MANUFACTURER. ALL FUSES IN ANY DISC.. SW SHALL BE OF THE SAME MANUFACTURER AND SHALL BE MANUFACTURED BY BUSSMANN, GOULD SHAWMUT OR EQUIVALENT. BEFORE PERMITTING OR START OF CONSTRUCTION: 1. TENANT TO ACQUIRE LANDLORD WRITTEN APPROVAL OF ALL PROPOSED ALTERATIONS. 2. CONTRACTOR TO VERIFY ALL EXISTING DIMENSIONS AND ELEVATIONS. 3. CONTRACTOR TO COORDINATE ROUGH WINDOW/ DOOR OPENINGS SIZE W/ MFR SPECS Q � I o o� T itW>-(n-OZ0 E- C\2 It O Lo Q Co co H QQ 04 O � E z a a O W x N W > a a W � ZZp CJ > z O Lo r-I L Z WU 3 WU 3 W v v W a a ii5 GCE MAZEN A Z O a U_ LL U L LJ CL U) J Q U_ L.L U LLJ _I W Lo �jj t` O d' U C') I 00 to c I � I` C\2O �' a w O z O CO a w U U cd F, ILI U E- U a N E- S.: O L� e� a O W t` d co JOB. NO. 21040 COA. NO.29116 ►RIE, PE. E3.0 i ■