HomeMy WebLinkAbout5947 Gall BlvdI I I I ALL WORK SHALL COMPLY WITH NFFA CODES AND STANDARDS GENERAL NOTES A. FIELD VERIFY ALL DIMENSIONS PRIOR TO COMMENCEMENT OF WORK. ?, , Z B. SEE 514EET A302 FOR EQUIPMENT SCHEDULE. REVIEW DATE •A� C. SEE SWEET A320 FOR PARTITION TYPES. CITY OF ZEPHYRH LLS /` D. E. SEE SWEET A600 FOR ELEVATIONS. SEE SHEET MW FOR FINISH SCHEDULE. FIRE AND LIFE SAFETY EXAMINER L�- FLOOR PLAN SCALE- 1/4' • 1'-0' 1 O KEYNOTES O I. REINSTALL EXISTING WALL HUNG FIRE EXTINGUISHER. GC TO REFURB45H AS REQUIRED TO MEET THE REQUIREMENTS OF NFPA 10 AND INSPECTION BY JURISDICTION HAVING AUTHORITY. 2. WALL HUNG TANKLESS WATER NEATER. REFER TO PLUMBING DRAWINGS. 3. CUSTOM MILLWORK BY FOOD SERVICE VENDOR. SEE EQUIPMENT L15T ON A302. 4, NEW HAND SINK. COORDINATE LOCATION WITH LOCATION OF NEW EQUIPMENT. SEE PLUMBING DRAWINGS. SEE EQUIPMENT SWEET A302. 5. TV TO BE CEILING MOUNTED. 6. ALIGN FINISHED FACE WITH FINISHED FACE. 7. PROVIDE ADA COMPLIANT RESTROOMI SIGNAGE. SEE DETAIL 7/A600. 8. 3-COMP. SINK AND GREASE TRAP. SEE PLUMBING DRAWINGS. 9. MOP SINK WITH DURAGUARD WALL GUARDS. SEE PLUMBING DRAWINGS. 10. NEW 101b CLA55 K WALL HUNG FIRE EXTINGUISHER WITH REQUIRED INSTRUCTIONS. II. TV TO BE WALL MOUNTED TO MEET THE MINIMUM REQUIREMENTS OF F13C ACCE551BILITY CODE, SECTION 307. 12. LINE OF SOFFIT/WEADER ABOVE. 13. A CO2 MONITORING SYSTEM WITH AUDIBLE AND VISUAL ALARM SHALL BE INSTALLED PER NFPA REQUIREMENT5, THE MONITOR SHALL BE EQUAL TO CO2METER.COM, MODEL RAD-01002-6, WITH DUAL STROBE CM-1026. THIS WILL BE INSTALLED NEAR THE CO2 SOURCE AND PER MANUFACTURER'S RECOMMENDATIONS. 14. NEW PREP SINK. REFER TO PLUMBING DRAWINGS AND EQUIPMENT SHEET A302. 15. PROVIDE FLOATING PLAM COVERED V MDF COUNTER AND 4' SPLASH WITH WALL BRACKET SUPPORT BELOW, FULL WIDTH OF OFFICE, AT 36' AFF. SCRIBE COUNTER TO WALL. CAULK PERIMETER. 16. NEW ELECTRICAL PANEL. REFER TO ELECTRICAL DRAWINGS. PANEL TO BE RECESSED AS MUCH AS P0551BLE INTO PARTITION. GC TO MINIMALLY FURR OUT FACE OF PARTITION AS REQUIRED AT PERIMETER. 17. DINING ROOM TV. SAMSINJG 75' LED NU6900. MOUNT TV AT 7'-2' AFF TO CENTER OF TV. 18. EXISTING CMU DEMISING PARTITION WITH GYPSUM FURRING. GC TO FIELD VERIFY FIRE RE515TANCE RATING OF A MINIMUM 2 HOUR PROTECTION. SEAL PARTITION TO DECK ABOVE AS REQUIRED. SEE 514EET A320 FOR UL DETAIL. REQUIRED FIRE RATED TENANT SEPARATION WALL UPGRADES SHALL BE PAID FOR BY LANDLORD. 19. G.G. TO REMOVE BOTTOM 12' OF GYPSUM WALLBOARD FROM EXISTING WALLS (ON KITCHEN 51DE ONLY) AND REPLACE WITH 5/8' CEMENT BOARD. PROVIDE CONTINUOUS SEALANT AT WALL/FLOOR INTERFACE. I KEY PLAN 1 NTS C&K ARCHITECTS I INTERIORS cmtdwck"-hww d"w-egad mvbm AAC001629 4221 WEST BOY SCOUT BLVD., SUITE 150 TAMPA. EL 33607-5/43 813.884.2000 280 WEST CENTRAL AVE. WINTER HAVEN. FL 33880-2957 863.577.2054 P O Q oa V O 0. I � rb�'1c fs22 4 i n i .A N a 0 0 ICY O m LL- cL cf) z 10 0 0 m 0 z m W ix ISSUED FOR: PERMIT FROJECI NUMBER 21020 DATE 5.5.21 DRAWING NUMBER A301 -- 4 J Li [:1 Ll I 0 I _ I I I i i l 1 Ttt' 42 40 DINING � I II I 4i L 1` 7 ❑ ABOVE 9 18 Q SERVICE �� LINE 32 -F" Fwi - - r - ,--ii�--�-- p III ( -, 24 p 25 � II M It III LQ FLOOR PLAN SCALE: 1/4' = 1'-0' GENERAL NOTES A. EQUIPMENT SHOWN 15 PURCHASED BY TENANT, INSTALLED FOOD SERVICE VENDOR UNLESS NOTED OTHERWISE. CONNECTIONS TO PLUMBING, POWER AND GAS BY G.C. B. PROVIDE ALL REQUIRED BLOCKING IN PARTITIONS AND CEILINGS A5 REQUIRED FOR INSTALLATION OF EQUIPMENT AND ACCESSORIES. C. REFERENCE PLUMBING AND MECHANICAL DRAWINGS FOR RELATED SPECIFICATIONS. I ❑ EQUIPMENT LIST ❑ I. GARBAGE/RECYCLING CENTER 2. ICE CUBER 3. MENU BOARDS PROVIDED AND INSTALLED BY G.C. SAMSUNG 50' LED UN50NU. 4. WALK-IN COOLER V X 10' S. POINT-OF-U5E WATER HEATER PROVIDED AND INSTALLED BY G.C. 6. PREP SINK 7. POS PROVIDED AND INSTALLED BY TENANT. 8. SANDWICH/5ALAD PREP FRIDGE 9. 3 PAN HOT SERVING COUNTER 9A. CUTTING BOARD (NOT SHOWN). KU. HEAT LAMP II. FOOD TOPPING WARMER 12. SANDWICH PANINI GRILL 13. REACH -IN FREEZER 14. CAN OPENER (NOT SHOWN) 15. REFRIGERATED EQUIP. STAND 16, 55 WORK TABLE 36' X 30' 17. 55 WORK TABLE 48' X 30' 18. 55 WORK TABLE 60' X 30' 19, 55 WORK TABLE 72' X 30' 20. 55 SHELVING 36' X 12' 21. 55 514ELVING 60' X 12' 22. RICE COOKER 23. 3-COMP.SINK 24. GAS GRIDDLE AV 25. GAS GRIDDLE 24' 26. GAS FRYER 27. HOT PLATE (NOT SHOWN) 27A. GAS HOSE KIT 27B. 55 STAND 24' X 30' 26- NAND SINK 29. SOAP DISPENSER PROVIDED AND INSTALLED BY G.G. ECOLAB NEXA - SURFACE MTD. 30, SANDWICH PREP 31. 55 SHELF 12' X 36' 32. 14' EXHAUST AND SUPPRE55ION HOOD PROVIDED AND INSTALLED BY G.G. 33. HOOD UTILITY CABINET PROVIDED AND INSTALLED BY G.G. 34. APW FOOD WARMER 35. METRO SHELVING 48' x 24' 36. METRO SHELVING 36' X 24' 37. METRO SHELVING 60' X 24' 37A. SHELF WITH METAL FRAME 375. SHELF WITH METAL FRAME 38. GREASE TRAP PROVIDED AND INSTALLED BY G.G. 39. MOP SINK AND DURAGUARD WALL GUARDS 67.2424 PROVIDED AND INSTALLED BY G.C. 40. PLPSI CODER BY TENANT VENDOR. Al. PEPSI DISPENSER BY TENANT VENDOR. 42. TV PROVIDED AND INSTALLED BY G.C. SAMSUNG 75' NU6900. 43. SNEEZE GUARD PROVIDED AND INSTALLED BY G.C. DK HARDWARE PP65 LEBS. 44. WALL MOUNTED SHELVING (ABOVE) 45. BAG IN BOX SYSTEM PROVIDED BY TENANT, INSTALLED BY G.C. 46. REACH IN FREEZER 47. PAPER TOWEL HOLDER PROVIDED AND INSTALLED BY G.C. GP PRO VISTA DISPENSER #310052 48. 55 WORK TABLE 30' X 24' 49. WIRE SHELVING 36' X 18' A CUSTOM MILLWORK BY FOOD SERVICE VENDOR B. BANQUETTE SEATING PROVIDED AND INSTALLED BY G.C. C. TABLE AND CHAIRS BY TENANT D. ADA SEATING 1 0 KEYNOTES O I. TENANT PROVIDED GC INSTALLED BAG -IN -BOX SYSTEM/ SOFT DRINK DISPENSER. VENDOR TO PROVIDE STEEL NK HOLDER TAWITH SAFETY STRAP. GC TO PROVIDE CONDUIT. G.C. TO PROVIDE SELF-ADHESIVE LAMINATED VINYL LABEL AT FACE OF MILLWORK ON EMPLOYEE SIDE STATING 'CAUTION -CARBON DIOXIDE', PART #S-8185 BY MY5AFETYSIGN.COM OR EQUAL. SEE DETAILS ON A700. C&K ARCHITECTS I INTERIORS alclYlochae-Mello Eaki+.aelx aorv:. AAC001929 4721 WEST BOY SCOUT Bl VD.. SUITE 150 TAMPA, FI 33607-5743 813.884.2000 280 WEST CENTRAL AVE. WINTER I IAVEN. FL 33880.2957 W6 S77.2054 co * 'L C, W o. I � vbf-fy8 O`y D 0 z x Z g � ss Z W 90 d LLA E a 0 m W m m m U' M P In IMUED FOR: PERMIT PROJECT NUMBER 21020 DATE 5.5.21 DRAWING NUMBER A302 11 I '11! 1 _ I Art _I_L. -- 8 .., ILI. 1 1 IIMPIrl 9m1 1 ", u. 1"'I. I 11 I. 1 _ I GENERAL NOTES A. ALL CONCENTRATED LOADS APPLIED TO THE TRU55 SHALL BE INSTALLED WITHIN 6' OF THE TRUSS PANEL POINT AT THE CHORD TO WHICH THAT LOAD 15 BEING APPLIED WHENEVER POSSIBLE. WHERE LOAD DISTANCE FROM PANEL POINT EXCEEDS 6', A WEB STIFFENER WILL BE REQUIRED CONNECTING THE POINT OF 714E LOAD TO THE NEAREST PAENL POINT AT THE OPPOSITE CHORD. B. JOIST STIFFENER REQUIRED IF CONCENTRATED LOAD 15 GREATER THAN 151# OR IS LOCATED MORE THAN 6" FROM TRUSS TOP OR BOTTOM CHORD OF PANEL. SEE DETAIL 2. II ,o II II II II II II II II II II 6" 6' 6 b II � II O KEYNOTES O II MA II RTU-I I I 1. ROOF OPENING SIZE PER MANUFACTURER'S CERTIFIED 4 DRAWING. 3[12 7 II II 2. 6' x 4' x 3/8' STEEL ANGEL(L.L.H.) x O'-W LONG (TYPICAL). I ( ROOF TOP UNIT FRAME SCHEDULE UNIT HEIGHT ANGLE SIZE 4 I I 3. BAR JOIST. 0-1,000 LB5 [ 3x3x1/4' 30 4. 3' x 3' x I/4' STEEL ANGLE. 1,001-2,500 LBS L 4x4xI/4' I I I I 2,5001-6,000 LEIS L 6x6x3/8' 5. JOIST STIFFENER AS REQUIRED. 24 I I N I I 6. 3/16' FILLET WELD, ALL AROUND. OVER 6' 8 7. TO NEAREST TOP CHORD PANEL POINT. 13 9 I I I I 8. BOTTOM CHORD PANEL POINT. 19 I 9. CONCENTRATED LOAD GREATER THAN 15I#. — — — — 23 9 I I EF I ( I EF I I 10. CONCENTRATED LOAD LESS THAN 151# AND WITHIN 6' OF PANEL POINT -NO STIFFENER REQUIRED. 20 21 3 IS b' II I I I I II. TOP CHORD PANEL POINT. 12. ANGEL PLACED DIRECTLY UNDER HVAC UNIT CURB- 5 13. LINE OF HVAC UNIT. 22 3 I I I I W. IF DECK OPENING REQUIRED ONLY AT HVAC DUCT WORK. I I I I USE 3' x 3' x 1/4' STEEL ANGLE TO SUPPORT DECK AT OPENING. REFER TO CURB ATTACHMENT DETAIL TH15 SHEET 4 I I I I 15. ANGLE SIZES PER SCHEDULE. 8 I I I I 25 16. 6' x 4' X 3V STEEL ANGLE X a-8' LONG LLV 1 17. EXTEND ANGLE, AS REQUIRED, FOR UNITS OVER 0-0' LONG. 00-I 15. FIELD WELD DECK TO PERIMETER ANGLE ALL 4 SIDES. 19. #12 TEK SCREWS INTO CURB, 4' FROM EACH CORNER AND @ 4 CURB ATTACHMENT DETAIL 2 BAR J0I5T STIFFENER RT"-2 24' O.C. MAX. MINIMUM 3 SCREWS PER SIDE, TYPICAL ALL 4 DETAIL i SIDES. SCALE: 3/4' = I'-O' SCALE: 3/4' = 11-0' (I 20. #12 TEK SCREWS 0 6' O.C. AT CURB TO DECK. 21. ROOFING SYSTEM. 1 22. HVAC SUPPORT FRAME MEMBER. REFER TO WAC SUPPORT FRAME DETAIL THIS SHEET. i 17 I i 5 q 3 I I I I I I 30 I I 23, ROOF TOP CURB. 12 13 , 24. 1/8' FILLET WELD, ALL AROUND. 1 1 1 2 ,IVERIFT I I 25. NEW RTU WITH NEW CURB. SEE MECHANICAL DRAWINGS. 1 ------- ----------------- EF PROVIDE NEW ROOF OPENING AND SUPPORT STRUCTURE FOR 1 1 18 b'OC26. 15/8" I I NEW OPERATING WEIGHT. NEW CONDENSATE PIPING. DISCHARGE TO NEAREST GUTTER. :e L REFERENCE MECHANICAL DRAWINGS. 1 r 1 r 1 1 1 1 1 PLAN VIEW 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 I 1 1 1 1 1 1 1 1 1 1 1 1 1 Ib 18 PERIMETER 4 1 1 OPENING 5/8 1 3 1Li1 15 FIELD VERIFY b 1 - 1 SECTION VIEW ROOF PLAN 3 HVAC SUPPORT FRAME I ROOF OPENING FRAMING SCALE= 3/4' = I'-0' SCALE: 3/8' - P-0' C&K ARCHITECTS I INTERIORS ..tft.tA h9r0r OftM-dk dG It— AAC001029 4221 WEST BOY SCOUT BLVD.. SLATE 150 TAMPA. FL 33607-5743 813.884.2000 280 WEST CENTRAL AVE. WINTER HAVEN. FL 33880-295/ 863.577.2054 �Y �i IdQC1 X o" J O.44 I O� .m d•;6 C., Y6f1�13 s - -- ID n ZN � O L.L.. 0 ^� m J I 90 N0 LLI ` H m c) m Q m P ISSUED FOR: PERMIT PROJECT NUMBER 21020 DATE 5.5.21 DRAWING NUMBER A303 I I __I I -__ u. _jI! I_ i4In muLl ! III .I -I 1. I 11BI I'!. I I I _. I I I I ll. A II MECHANICAL SMCMATIONS MECHAMCAL LEG END RIGID DUCT - DOUBLE LINE PART 1 - GENERAL 2.02 ACCESS PANELS, FIRE DAMPERS, AND FIRE/SMOKE DAMPERS 2-08 DUCTWORK CONSTRUCTION ROUND STEEL DUCT GAGE 0.01 GENERAL SCOPE A. THEGETIERAI. AND MECHANICAL CONTRACTORS SHALL PROVIDE A. THE $MEET METAL AND AIR CONDITIONING CONTRACTORS' NATIONAL DUCT LONGITUDINAL PART 3-EXECDRON RIGID DUCT- SINGLE LINE A THIS PROJECT WILL REQUIRE INSTALLATION OF NEW HVAC SYSTEMS AS ACCESS PANELS TO ALLOW ACCESS TO VOLUME DAMPERS ABOVE ASSOCIATION'S'FlBROUS GLASS DUCT CONSTRUCTION STANDARDS' DIAMETER SPIRAL SEAM SEAM INDICATED. PIASTER OR GYPSUM CEILINGS, TURNING VANES, FIRE DAMPERS, AND 9HVAC DUCT CONSTRUCTION STANDARDS• SHALL BE IN INCHES IN INCHES IN INCHES 3.01 INSTALLATION FLEXIBLE OUCH -INSULATED, SINGLE LINE FIRE/SMOKE DAMPERS, DUCT -MOUNTED SMOKE DETECTORS, AND CONSIDERED PART OF THE SPECIFICATIONS FOR THIS PROJECT. ANY 1.01 GENERAL DOCUMENTS WHERE. REQUIRED FOR THE MAINTENANCE OF ALL MECHANICAL WORK THAT DOES NOT COMPLY WITH THESE STANDARDS MAY BE 3-8 28 28 A OCOORDINATE WORK WITH OTHER TRADES AND EXISTING CONDITIONS \_/ FLEXIBLE DUCT - INSULATED EQUIPMENT. ACCESS PANELS SHALL HAVE A FIRE RATING EQUAL TO REJECTED AT ANY TIME DURING THE PROJECT. 9- 14 25 26 PRIOR TO BEGINNING WORK. MECHANICAL CONTRACTOR SHALL PROVIDE A INSTALLATION SHALL HE IN ACCORDANCE WITH THE FLORIDA BUILDING THE PENETRATED ASSEMBLY, WITH A MINIMUM FIRE RATING OF ONE (1) 15 - 26 26 24 ROOTING AND OFFSETS NECESSARY TO AVOID CONFLICT WITH CODE TIM EDITION 2020 (EFFECTIVE 12I31202D), WHICH INCLUDES THE HOUR, B. REFER TO BASIC MATERIAL REQUIREMENTS ON THIS SHEET FOR 27 - 30 24 22 STRUCTURE. FINISHES, AND WORK OF OTHER TRADES. ® SUPPLY AIR DUCT - SECTION RORIDA BUILDING CODE, MECHANICAL., FLORIDA RUADING CODE, DUCTWORKAND DUCT INSULATION MATERIAL SELECTIONS- 37-50 22 20 ENERGY CONSERVATION, AS WELL AS FLORIDA FIRE PREVENTION CODE, B. THE MECHANICAL CONTRACTOR SHALL ATTACH A DRIGHRY-COLORED 51 60 20 18 RETURN 7TH EDITION 2020 (EFFECTIVE 12)31Y102% ALL EQUIPMENT SHALL BE UL STRIP OF PLASTIC TAPE TO EVERY DUCT -MOUNTED ACCESS PANEL THE C M I DU CT DIMENSIONS SHOWN ON THE CONSTRUCTION DOCUMENTS 61 - 84 18 16 3.02 DISNFECTNG OF POTABLE WATER SYSTEM AIR DUCT -SECTION LIST ED. STRIP SHALL BE OF SUFFICIENT FENCE TO HANG A MINIMUM OF 12" ARE INSIDE CLEAR DIMENSIONS. THE MECHANICAL CONTRACTOR BELOW THE BOTTOM OF THE ASSOCIATED DUCT. SHALL PROVIDE FLEXIBLE CONNECTIONS BETWEEN EACH ITEM OF ROUND At UMINIAN DUCT GAGE A. THE SYSTEM SHALL BE FILLED WITH A SOLUTION CONTAINING 50 PARTS 0 DUCT TRANSITION - SINGLE LINE S. THE MECHANICAL. WORK SHALL INCLUDE FURNISHING ALL. LABOR MECHANICAL EQUIPMENT AND ITS ASSOCIATED DUCT'(S). ALL ITEMS DUCT LONGITUDINAL PER MILLION OF AVAILABLE CHLORINE AND ALL ALLOWED TO STAND 24 EQUIPMENT, MATERIALS AND SERVICE NECESSARY FOR AND C. THE MECHANICAL CONTRACTOR SHALL PROVIDE A FIRE DAMPER AT OF THE HEATING, VENTILATION, AND AIR CONDITIONING SYSTEM DIAMETER SPIRAL SEAM SEAM HOURS BEFORE FLUSHING AND RETURNING TO SERVICE. DISINFECTION � DUCT TRANSITION REASONABLY INCIDENTAL TO THE PROPER COMPLETION OF ALL EVERY DUCT PENETRATION OF A FIRE -RATED ASSEMBLY AND A INCLUDING, BUT NOT LIMITED TO, AIR HANDLERS, FANS, DUCTWORK, IN INCHES IN INCHES IN INCHES PROCEDURE AND RESULT SHALL BE SUBJECT TO THE APPROVAL OF THE MECHANICAL WORK SHOWN ON THE. DRAWINGS AND AS SPECIFIED. ALL FIRE/SMOKE DAMPER WITH A MINIMUM FIREISMOKE RATING OF TWO (2) DIFFUSERS. AND GRILLES SHALL NOT BE SUPPORTED BY THE CEILING LOCAL MECHANICAL INSPECTOR ELBOW WITH'AIRFOIL' TURNING VANES 16 MATERIAL SHALL BE NEW. HOURS AT EVERY DUCT PENETRATION OF A SMOKE ASSEMBLY OR OR CEILING SUSPENSION SYSTEM, BUT INSTEAD SHALL BE 3 -14 .026 .032 CHASE EACH FIREISMOKE DAMPER SHALL CLOSE AND THE SUPPORTED BY THE BUILDING STRUCTURE. 15- 26 .032 .040 3.03 TEST �y-� C. EACH PROSPEC DVF MECHANICAL CONTRACTOR SHALL EVALUATE THE ASSOCIATED AIR HANDLER SHALL SHUTDOWN IF EITHER OF THE AIR 27 - 36 .040 .050 1 - I IVD MANUAL VOLUME DAMPER (VD) SCOPE OF WORK THOROUGHLY PRIOR TO SUBMITTING A BID. HANDLERSES ' OR THE SPACSMOKE DETECTORS ARE AC RVATED. D. ALL ELBOWS SHALL HAVE A ONE AND ONE-HALF (1.5) CENTERLINE 37 - 50 .050 .063 A. ALL MECHANICAL SYSTEMS SHALL BE TESTED IN ACCORDANCE WITH THE 7a'NY�'+ RADIUS -TO -WIDTH OR RADIUSTO-DEPTH RATIO OR SHALL BE ZOO DUCT LEAKAGE PERFORMANCE FLORIDA BUILDING CODE MECHANICAL. ALL TESTS SHALL BE APPROVED BY D. SOME CONDUIT, PIPING, AND OTHER OBSTACLES MAY NEED TO BE D_ THE MECHANICAL CONTRACTOR SHALL PROVIDE ADDITIONAL CONSTRUCTED WITH SINGLE BLADE TURNING VANES. ANGULAR THE LOCAL MECHANICAL INSPECTOR AND SHALL BE OBSERVED BY A RELOCATED AND SUCH RELOCATION SHOULD BE INCLUDED IN EACH DUCTWORK AND PIPING SUPPORTS WITHIN EIGHTEEN (18) INCHES OF TAPERS SHALL BE LIMITED TO THIRTY (30) DEGREES FOR A FOR AIR CONDITIONING SYSTEMS OF FIFTEEN (15) TONS OR REPRESENTATIVE OF THE ARCHITECT. ® SUPPLY AIR DIFFUSER PROSPECTIVE MECHANICAL CONTRACTOR'S BID- BOTH SIDES OF ALL FIRE -RATED ASSEMBLIES. DUGTWORK AND PIPING CONTRACTING TAPERS AND TWENTY (20) DEGREES FOR EXPANDING GREATER CAPACITY, AN INDEPENDENT TEST AND BALANCE SHALL NOT BE SUPPORTED BY FIRE -RATED WALLS, BUT INSTEAD SHALL TAPERS. CONTRACTOR SHALL PERFORM A DUCT LEAKAGE TEST IN 3.04 SYSTEM IDENTIFICATION RETURN AIR OR VENTILATION EXH. GRILLE E. THIS ENGINEER 13 NOT RESPONSIBLE FOR MATERIALS. METHODS. BE SUPPORTED BY THE BUILDING STRUCTURE COMPLIANCE WITH SMACMA'S'HVAC AIR DUCT LEAKAGE TEST INSTALLATION, AND CONSTRUCTION WHICH DEVIATE FROM THESE CONSTRUCTION DOCUMENTS AND SPECIFICATIONS. 2.03 SMOKE DETECTORS E. THE MAXIMUM LENGTH OF NEW FLEXIBLE DUCT SHALL BE 1014Y. FLEXIBLE DUCT SHALL BE INSTALLED AND SUPPORTED SO AS TO MANUAL" TO VERIFY THE FUNCTION OF THE DESIGN AND THE WORKMANSHIP OF THE MECHANICAL CONTRACTOR. A DUCT A THE MECHANICAL CONTRACTOR SHALL PROVIDE IDENTIFICATION TAGS FOR ALA. NEW EQUIPMENT, PIPING AND VALVES IN THE BUILDING. TAGS ® EXHAUST AIR GRILLE OR CEILING PREVENT THE USE Or EXCESS DUCT MATERIAL, PREVENT LEAKAGE TEST USED TO CONFIRM DUCT LEAKAGE CLASS SMALL BE METAL WITH ENGRAVED UNIT/TAG NUMBER. MOUNTED EXHAUST FAN 1.02 SUBMITTALS A. INDIVIDUAL AIR HANDLING SYSTEMS WITH A DESIGN CAPACITY OF MORE SMALL DISLOCATION OR DAMAGE, AND PREVENT CONSTRICTION OF THE DUCT BELOW THE RATED DUCT DIAMETER FLEXIBLE DUCT BENDS SHALL BE CONDUCTED AT THE PRESSURE FOR WHICH THE DUCT WAS DESIGNED AND CONSTRUCTED. 3.05 TESTING, ADJUSTING. BALANCING AND COMMISSIONING O O A MATERW S OR PRODUCTS SPECIFIED HEREIN AND/OR INDICATED ON THAN 2000 CFM AUTOMATICALLY SHUT DOWN BY MEANS OF AN APPROVED SMOKE DETECTOR PLACED IN THE SUPPLY AIRFLOW AFTER SHALL MAINTAIN A CENTERUME RADIUS OF NOT LESS THAN ONE AND THERMOSTAT OR HUMIDISTAT - WALL MOUNTED DRAWINGS BY TRADE NAME, MANUFACTURER'S NAME OR CATALOG ANY AIR FILTERS AND BEFORE ANY BRANCH CONNECTIONS IN THE ONE-HALF (1.5) DUCT DIAMETERS. SAGS SHALL NOT EXCEED B. DUCT CONSTRUCTION AND SEALING SYSTEMS SHALL MEET THE BE THE MECHANICAL CONTRACTOR SHALL ENSURE THAT THE MEC 4AMCAL DUCT SMOKE DETECTOR NUMBERS SHALL BE INTERPRETED AS ESTABLISHING A STANDARD OF SUPPLY DUCTWORK ONE-HALF (LIES) INCH PER LINEAR FOOT OF FLEXIBLE DUCT. HANGERS, REQUIREMENTS OF THE FLORIDA ENERGY CONSERVATION SYSTEMS ARE TESTED AND BALANCED. OUALI I Y AND DESIGN. SUBSTITUTIONS MAY BE ALLOWED IF THEY MEET SADDLES, AND OTHER SUPPORTS SHALL HAVE A MINIMUM WIDTH OF CODE AND SMACNAS "FIBROUS GLASS DUCT CONSTRUCTION THE QUALITY STANDARDS AND DESIGN IN ITNUNLESS UNLESS OTHERWISE S. MULTIPLE AIR HANDLING SYSTEMS SERVING THE SAME SPACE WITH A ONE AND ONE-HALF (1.5) INCHES. THE MECHANICAL CONTRACTOR STANDARDS' AND'HVAC DUCT CONSTRUCTION STANDARDS'. C. THE MECHANICAL CONTRACTOR SHALL PERFORM ALL TESTING. �-U - 3/4-UNDERCUT NOTED. COMBINED DESIGN CAPACITY OF MORE THAN 2000 GEM SHALL SHALL PROVIDE SUPPORT FOR NEW AND MODIFIED EXISTING FLEXIBLE IF THERE IS A CONFECT AMONG THE STANDARDS, THEN THE ADJUSTING, BALANCING, AND DATA RECORDING NECESSARY TO AUTOMATICALLY SHUT DOWN BY MEANS OF AN APPROVED SMOKE DUCTWORK IN'I HE SCOPE OF WORK WITH A MAXIMUM SPACING OF MORE STRINGENT STANDARD SHALL BE ENFORCED. ESTABLISH THE CAPACITY AND QUALITY OF THE SYSTEMS AND CONFIRM -G-� 16X16 DOOR GRILLE e. PRIOR TO STARTING THE PROTECT, THE MECHANICAL CONTRACTOR SHALL STUDY THE COMPLETE SE Of CONSTRUCTION DOCUMENTS AND DETECTOR PLACED IN THE SUPPLY AIRFLOW AFTER ANY AIR DETERS AND BEFORE ANY BRAVED CONNECTIONS IN THE SUPPLY DUCTWORK, F-W. UNLESS OTHERWISE NOTED ON THE CONSTRUCTION DOCUMENTS OR AUTHORIZED BY MECHANICAL ENGINEER OF RECORD. C EA THE MECHANICAL CONTRACTOR SHALL SEAL ALL TRANSVERSE THE SATISFACTORY COMPLETION OF ALL ASPECTS OF THE SCOPE OF WORK THIS WILL INCLUDE ALL SYSTEMS WITHIN THE SCOPE OF WORK COORDINATE WITH THE MANUFACTURER(S) AS REQUIRED TO PROVIDE AS WELL AS AN APPROVED SMOKE DETECTORPLACED IN THE RETURN JOINTS, LONGITUDINAL SEAMS, AND DUCT WALL ANYTIME FLOWS OR CALCULATIONS ARE SHOWN ON PLANS, DETAILS OR SPIN -IN FITTING WITH VOLUME DAMPER EQUIPMENT SUBMITTALS TO SUBMIT TO IRIS ENGINEER FOR REVIEW AIRFLOW AFTER ANY BRANCH CONNECTIONSTIONSIN THE REl'URN F. SURFACES UPON WHICH CLOSURE OR SEALING PRODUCTS ARE TO BE PENETRATIONS TO A MAXIMUM ALLOWABLE DUCT LEAKAGE SCHEDULES, TEST 8 BALANCE IS REOlIREO. AND APPROVAL. THE EQUIPMENT SUBMITTALS SHALL INCLUDE DUCTWORK AND BEFORE ANY EXHAUST OR OUTSIDE AIR APPLIED SHALT- BE CLEAN AND DRY IN ACCORDANCE WITH THE CLASS OF THREE (3) CFM PER 100 SQUARE FEET OF DUCT AREA DIMENSIONS. WEIGHTS, SPECIFIED ACCESSORIES AND REQUIRED CONNECTIONS. MORE INFORMATION IS AVAILABLE IN CHAPTER 4 OF MANUFACTURER'S INSTALLATION INSTRUCTIONS. ALL DUCTWORK (1.5%) FOR ROUND DUCT AND SIX (6) CFM PER 100 SQUARE rBODI BACKDRAFT DAMPER CLEARANCES. AS WELL AS FAN CURVES. SOUND LEVELS, CONSTRUCTION NFPA IBA SHALL BE SEALED WITH A NON -HARDENING, NON -MIGRATING MASTIC FEET OF DUCT AREA (3%) FOR ALL OTHER DUCT TYPES. O. THE MECHANCAL CONTRACTOR SHALL ENSURE THAT THE BUILDING IS DETAILS, WARRANTY INFORMATION, AND ALL OTHER RELEVANT DATA OR LIQUID ELASTIC SEALANT AS REQUIRED TO MEET THE FLORIDA UNLESS OTHERWISE NOTED ON THE CONSTRUCTION UNDER POSITIVE PRESSURE AT THE CONCLUSION OF THE TEST AND ENERGY CONSERVATION CODE. THE MECHANICAL CONTRACTOR DOCUMENTS OR AUTHORIZED BY MECHANICAL ENGINEER OF BALANCE PROCESS. IF THE BUILDING IS NOT UNDER POSITIVE PRESSURE MD MOTORIZED DAMPER C. IF ALTERNATES TO THE BASIS OF DESIGN ARE SUBMITTED, THE C. THE MECHANICAL CONTRACTOR SHALL INCLUDE IN HIS/HER BID ALL SMALL PROVIDE HOT -DIPPED GALVANIZED STEEL FASTENERS, RECORD. TRANSVERSE. JOINTS ARE CONNECTIONS OF TWO AT THE CONCLUSION OF THE TEST AND BALANCE PROCESS, THEN THE MECHANICAL CONTRACTOR SHALL PROVIDE A CLEAR, DETAILED H COSTS ASSOCIATES W FURNISHING, T AND WIRING ALL ANCHORS, RODS. STRAPS. TRIM, AND ANGLES FOR INTERIOR DUCT OR FITTING ELEMENTS ORIENTED PERPENDICULAR TO TEST AND BALANCE AND MECHANICAL CONTRACTORS SHALL IMMEDIATELY SUMMARY IN THE SUBMITTALS OF THE DIFFERENCES BETWEEN THE SMOKE DETECTORS. THIS WILL INCLUDE,, B NOT BUT NOT NECESSARILY BE DUCTWORK SUPPORTS. INTERIOR DUCTWORK SUPPORT SPACING THE DIRECTION OF THE AIRFLOW. LONGITUDINAL SEAMS ARE AND WITHOUT DELAY NOTIFY THE ARCHITECT AND MECHANICAL ENGINEER XX FD-FIRE DAMPER, SD=SMOKE DAMPER SUBMITTED EQUIPMENT AND THE BASIS OF DESIGN. MECHANICAL LIMITED TO, MAKING DUCTWORK MODIFICATIONS AS REQUIRED BY THE SHALL NOT EXCEED V-W. JOINTS ORIENTED IN THE DIRECTION OF THE AIRFLOW. DUCT OF RECORD. FSD = FIREISMOKE DAMPER ENGINEER OF RECORD MAY ACCEPT OR REJECT THE ALTERNATES. MANUFACTURER'S INSTRUCTIONS. THE GENERAL OR MECHANICAL WALL PENETRATIONS ARE OPENINGS MADE BY SCREWS, TO MATCH ASSEMBLY CONTRACTOR SMALL SUB -CONTRACT THE PURCHASE AND WIRING OF G ALL DUCTWORK INSULATION, FITTINGS, COVERS, AND FINISHES SHALL NONSAELF-SEUNG FASTENERS, PIPES. TUBING. RODS, AND E. THE MECHANICAL CONTRACTOR SHALL, UPON COMPLETION OF ALL PENETRATION RATING (1-HR, 2-HR. ETC.): 1.03 SHOP DRAWINGS ALL SMOKE DETECTORS TO THE ELECTRICAL CONTRACTOR TO ENSURE HAVE, A MAXIMUM FLAME SPREAD RATING OF 25. A MAXIMUM SMOKE WIRE ROUND AND FLAT -OVAL SPIRAL LOCK SEAMS NEED NOT NECESSARY TESTING AND BALANCING AND AT LEAST ONE (1) WEEK PRIOR PROVIDE ACCESS PANEL FOR ACCESS THE SMOKE DETECTORS' COMPATIBILITY WITH THE FIRE ALARM DEVELOPMENT RATING OF 50, AND SHALL BE IN COMPUANCE WITH BE SFAI FD PRIOR TO ASSEMBLY BUT SMALL RE COATED AFTER TO SUBSTANTIAL COMPLETION, SUBMIT THREE (3) BOUND COPIES OF THE A. PRIOR TO STARTING THE PROJECT, THE MECHANICAL CONTRACTOR SHALL SYSTEM. NFPA 90A PROVIDE MINIMUM OF W" FIBERGLASS WITH FOIL/SCRIM ASSEMBLY TO REDUCE LEAKAGE ALL OTHER CONNECTIONS TEST AND BALANCE AND COMMISSIONING REPORTS TO THE GENERAL Hb CONNECTION - NEW TO EXISTING WORK. STUDY THE COMPLETE SET OF CONSTRUCTION DOCUMENTS AND VAPOR BARRIER ON THE BACK PAN OF ALL NEW AIR DEVICES. ARE CONSIDERED TRANSVERSE JOINTS INCLUDING, BUT NOT CONTRACTOR AND MECHANICAL ENGINEER OF RECORD. COORDINATE WITH THE OTHER TRADES AS REQUIRED TO PROVIDE SHOP U. THE CONTRACTOR -PROVIDED INSTRUCTIONS TO THE OWNER FOR UNITED TO. SPINdNS, TAPS OR OTHER BRANCH CONNEC710NS, DRAWINGS TO SUBMIT TO MECHANICAL ENGINEER OF RECORD FOR OPERATING AND MAINTAINING ALL MECHANIST EQUIPMENT SNARL H- ALL OUTSIDE AIR INTAKES SHALL BE A MINIMUM OF 10.0' FROM ANY ACCESS DOOR FRAMES, AND DUCT CONNECTIONS TO F. THE MECHANICAL CONTRACTOR SHALL INCLUDE IN HISMER BID THE COST NEW LINE TYPE APPROVAL. TI1E SHOP DRAWINGS MAY BE SUBMITTED AS HAND -DRAWN INCLUDE TESTING ALL AUTOMATIC SHUTDOWN DEVICES AT LEAST ONCE EXHAUST DO RET OR VENT PIPE (UNLESS THE VENT PIPE IS AT LEAST EQUIPMENT. MORE INFORMATION 13 AVAILABLE IN CHAPTER 35 OF ANY SHEAVE CH AGES REQUIRED FOR REBALANCING THE SYSTEM. NOTES UPON A COPY OF THE CONSTRUCTION DOCUMENTS. THE PER YEAR SPECIAL INSTRUCTIONS SHALL BE GIVEN WITH REGARD TO TWO (2) FEET ABOVE THE OUTSIDE AIR IN TAKE). THE MECHANICAL OF ASHRAE'S "FUNDAMENTAL$ HANDBOOK". - - - - EXISTING LINE TYPE CONSTRUCTION DOCUMENTS ARE DIAGRAMMATIC IN NATURE AND ENSURING THAT SMOKE SENSING DEVICES ARE PROPERLY CLEANED CONTRACTOR SHALL PROVIDE SCREENS ON ALL OUTSIDE AIR INTAKES 3.06 SUBSTANTIAL AND FINAL COMPLETION INTENDED BOLDLY TO CLARIFY THE SCOPE OF WORK AND INDICATE THE AND CALIBRATED IN ACCORDANCE WITH THE MANUFACTURER'S AND EXHAUST OUTLETS AT NO LESS THAN 1/4" BY 114 AND NO D. ALL DUCTWORK SHALL BE INSPECTED BY MECHANICAL GENERAL ARRANGEMENT OF SYSTEMS. THE CONSTRUCTION DOCUMENTS REQUIREMENTS. MORE INFORMATION IS AVAILABLE IN CHAPTER 4 OF GREATER THAN 1? BY 1/2". THE MECHANICAL CONTRACTOR SHALL ENGINEER OF RECORD PRIOR TO BEING COVERED OR A THE MECHANICAL CONTRACTOR SHALL MAINTAIN A SET OF ARE NOT INTENDED TO ALERT THE MECHANICAL CONTRACTOR OF ALL NFPA 90k PROVIDE MOTORIZED DAMPERS IN ALL OUTSIDE AIR DUCTS. EACH INSULATED. . TOWNER AND MECHANICAL ENGINEER OF CONTINUOUSLY UPDATED, REPRODUCIBLE AS -BUILT DRAWINGS DURING OBSTACLES. THE SHOP DRAWINGS SHALL SHOW THE COORDINATION OF MOTORIZED DAMPER SHALL BE CONTROLLED TO OPEN IN OCCUPIED RECORD SHALL BE PRESENT DURING ALL DUCT LEAKAGE CONSTRUCTION AND PROVIDE A COMPLETE SET OF THOSE DRAWINGS IN MECHAMAL SHEET NIX DUCTWORK AND MECHANICAL EOLAPMENT INSTALLATION WITH EXISTING E THE MECHANICAL AND ELECTRICAL CONTRACTORS SHALL PROVIDE MODE. TESTING AND THE DUCTWORK SHALL BE TESTED AS BOTH ELECTRONIC AND HARDCOPY FORMATS TO THE GENERAL. AND NEW OBSTACLES INCLUDING. BUT NOT LIMITED TO, FL FCTRICAI. EACH AIR HANDLING SYSTEM WITH A MINIMUM OF ONE (1) INSTRUCTED BY MECHANICAL ENGINEER OF RECORD AND CONTRACTOR AND MECHANICAL ENGINEER OF RECORD UPON FINAL MECHANICAL GENERAL CONDUITS, FIRE PROTECTION PIPING, RAIN LEADERS, SANITARY DRAINS, MANUALLY -OPERABLE MEANS TO SHUT DOWN ALL SUPPLY. RETURN, 1. THE MECHANICAL CONTRACTOR SHALL PROVIDE AN OPPOSEDELADE RETESTED IF REQUIRED BY MECHANICAL ENGINEER DU COMPLETION. .1 STRUCTURAL MEMBERS, AND WATER PIPING, AS WELL AS THE MECHANICAL EXHAUST AND OUTSIDE AIR FANS IN AN EMERGENCY. MORE VOLUME DAMPER FOR EVERY RECTANGULAR BRANCH AND OUTLET RECORD. IF ANY DISCREPANCIES ARE IDENTIFIED, THE -- - - _ - - - - EOOIPIENTMANUFACTURERS' RECOMMENDED CLEARANCES- THE INFORMATION IS AVAILABLE IN CHAPTER 6 OF NFPA 80A AND AT EVERY RECTANGULAR TAKE -OFF FOR A DIFFUSER OR GRILLE. DUCTWORK SHALL BE UNCOVERED AND REPAIRS SHALL BE B. THE MECHANICAL CONTRACTOR SHWA CLEAN ALL COOLING AND HEATING' MECHANICAL DEMO PLAN MECHANICAL CONTRACTOR SHALL ALSO SHOW THE EXISTING CONDITIONS (ROUND OR OVAL BRANCHES. OUTLETS, AND TAKE -OFFS FOR MADE A MECHANICAL CONTRACTORS EXPENSE. THE COALS, CONDENSATE PANS, AND CONDENSATE DRAIN LINES PRIOR TO ON THE SHOP DRAWINGS WHERE THE D03TM0 CONDTONS ARE 2.05 CONDENSATE DRAIN LINES DIFFUSE AND GRILLES $DAL BE PROVIDED WITH STANDARD ITHE MECHANICAL CONTRACTOR SMALL ONE MECHANICAL SUBSTANTIAL COMPLETION. THE MECHANICAL CONTRACTOR SHALL ALSO M4.1 MECHANICAL PROPOSED DIFFERENT FROM THOSE SHOWN ON THE CONSTRUCTION DOCUMENTS. VOLUME DAMPERS.) NOT ALL DAMPERS ARE SHOWN ON THE ENGINEER OF RECORD TWO (2) WEEKS NOTICE BEFORE REPLACE ALL FILTERS AND BELTS PRIOR TO SUBSTANTIAL COMPLETION PLAN CONSTRUCTION DOCUMENTS. HOWEVER. DAMPERS ARE REQUIRED TESTING THE DUCTWORK AND PROVIDE TWO (3) COMPLETE REPLACEMENT SETS OF FILTERS AND (2) - - - - -- B. FURNISH SIX (6) COPIES OF SHOE' DRAWINGS OF E-0111PMINi. MATERIALS A REFER TO BASIC MATERIAL REQUIREMENTS ON THIS SHEET FOR EVERY BRANCH. OUTLET, AND TAKE -OFF. SOME DAMPERS MAY BE SETS OF BELTS FOR ALL MECHANICAL EQUIPMENT TO THE OWNER UPON M7.'1 - MECHANICAL SCHEDULES AND SYSTEM LAYOPI TO GENERAL CONTRACTOR AND MECHANICAL FOR CO. MATERIAL SELECTIONS REQUIRED AFTER TRANSITIONS. 2.10 AIR DEVICES IINN COMPLETION. ENGINEER OF RECORD PRIOR TO PURCHASING ANY EQUIPMENT AND BEGINNING WORK. e. THE MECHANICAL CONTRACTOR SHALL PROVIDE A P-TRAP AT J. THE. MECHANICAL CONTRACTOR SHALL. ATTACH A BRIGHTLY -COLORED A THE MECHANICAL CONTRACTOR SHALL VERIFY THE LOCATIONS MECHANICAL SCHEDULES EACH HANDLERS CONDENSATE DRAIN LINE CONNECTION. STRIP OF PLASTIC TAPE TO EVERY VOLUME DAMPER, EXCEPT THOSE OF THE DIFFUSERS AND GRILLES AND SUBMIT A 3.07 WARRANTY 1.a RECORD DRAWINGS EACH CONDENSATE DRAIN LINE SHALL BE SLOPED DOWN A AT THE HEAD OF A DIFFUSER OR GRILLE THE STRIP SHALL SE OF REQUEST -FOR -INFORMATION IF THERE IS A CONFLICT i MA.1 MECHANICAL DETAILS MINIMUM OF ONE -EIGHTH ( INCH PER LINEAR FOOT SUFFICIENT LENGTH TO HANG A MINIMUM OF 12" BELOW THE BOTTOM BETWEEN THE ARCHITECTURAL AND MECHANICAL PORTIONS A THE MECHANICAL CONTRACTOR SHALL WARRANT ITS WORK TO BE FREE A AFTER COMPLETION OF ALL WORK THE MECHANICAL CONTRACTOR SHALL TOWARD THE ASSOCIATED POINT POINT OF DISCHARGE. OF THE ASSOCIATED DUCT. OF THE CONSTRUCTION DOCUMENTS. THE MECHANICAL FROM DEFECTS IN MATERIALS AND WORKMANSHIP FOR A PERIOD OF ONE PROVIDE THE GENERAL CONTRACTOR WITH AS BUILT RECORD DRAWINGS. CONTRACTOR SHALL ALSO VERIFY THE TYPES OF CEILINGS IN YEAR FROM FINAL ACCEPTANCE OF ALL WORK. MECHANICAL CONTRACTOR SHALL L KEEP A RECORD OF THE LOCATIONS OF C. THE DIAMETER OF THE CONDENSATE DRAIN LINE SHALL BE THE SCOPE OF WORK PRIOR TO ORDERING DIFFUSERS AND ALL CONCEALED WORK AND UPON COMPLETION OF THE JOB, SHALL EQUAL TO OR GREATER THAN THE CONDENSATE DRAIN LINE K THE MECHANICAL CONTRACTOR SHALL CLEARLY AND PERMANENTLY GRILLES. FOR DIFFUSERS AND GRILLES LOCATED IN PLASTER B. THE MECHANICAL CONTRACTOR SMALL PROVIDE FIVE (5) BOUND COPIES SUPPLY AS -BUILT DRAWINGS SHOWING ANY DEVIATION FROM THE CONNECTION- TO AVOID EXCESSIVE DIPS IN AND TO PREVENT MARK EACH VOLUME DAMPERS OPEN AND CLOSED POSITIONS. THE OR GYPSUM CEILINGS, THE MECHANICAL CONTRACTOR SHALL OF ALL MECHANICAL CONTRACTOR WARRANTIES, MANUFACTURE. HS' ORIGINAL DRAWINGS. THESE DRAWINGS SHALL INDICATE DIMENSION OF ANY SHIFTING OF THE CONDENSATE DRAIN LINES, THE MECHANICAL CONTRACTOR SHALL PROVIDE A VOLUME DAMPER WITH PROVIDE METALAIRE MODEL TBPF / TINS MODEL TRM PLASTER WARRANTIES, PARTS LISTS, AND INSTALLATION AND MAINTENANCE AI SUMED UTILITYLINES FROM BUILDING WALLS. MECHANICAL CONTRACTOR SHALL PROVIDE SUPPORTS AT A T STANDOFF WITH A LOCKING QUADRANT THAT IS 24 GAUGES OR 2 FRAMES. THE FRAMES MAY BE ALUMINUM N NON -FIRE -RATED MANUALS FOR ALL MECHANICAL EQUIPMEN I, AS WELL AS INSTRUCTIONS THE FOLLOWING INTERVALSTHREE (3) FEET FOR GAUGES HEAVIER. CEILINGS BUT MUST BE STEEL. IN FIRE -RATED CEILINGS. THE FOR OPERATING AND MAINTAINING ALL MECHANICAL EQUIPMENT 70 THE PART 2 - INSTALLATION CONDENSATE DRAIN LINES CONSTRUCTED OF PVC, SIX (6) MECHANICAL CONTRACTOR SHALL. COORDINATE THE FINISH OF OWNER UPON FINAL COMPLETION. FEET FOR CONDENSATE DRAIN LINES CONSTRUCTED OF L PROVIDE AND INSTALL92USKIN PRD19' POSITIVE PRESSURE RELIEF ALL DIFFUSERS AND GRILLES. EXPOSED DUCTWORK, GRAVITY 2.01 EQUIPMENT COPPER AND TEN (10) FEET FOR CONDENSATE LINES DOORS IN SUPPLY DUCTWORK FOR ALL AIR HANDLER SYSTEMS WITH VENTILATORS, LOUVERS. AND WALL CAPS WITH THE CONSTRUCTED OF STEEL CONDENSATE DRAIN LINE VAV BOXES. SMOKE DAMPERS OR FIRE DAMPERS. PROVIDE AND (ARCHTECTIOWNER). ALL VISIBLE EXTERIOR COMPONENTS A ALL MECHANICAL EQUIPMENT SMALL BE INSTALLED AS REQUIRED BY THE SUPPORTS SHALL BE FIXED SOLIDLY IN PLACE. INSTALL"RUSKIN NRD-18 NEGATIVE PRESSURE RELIEF DOOR IN (SUCH AS EXPOSED DUCTWORK AND LOUVERS) SHALL BE MANUFACTURERS' INSTALLATION AND MAINTENANCE MANUALS. THOSE RE I URN DUCTWORK FOR ALL AIR HANDLER SYSTEMS THAT HAVE PROVIDED WITH A PAINT -GRIP FINISH. MANUALS WILL TYPICALLY PROVIDE MORE DETAIL THAN THE D. CONDENSATE DRAIN LINES SHALL L NOT BE ROUTED TO THE MOTORIZED RETURN AIR DAMPERS, SMOKE DAMPERS OR FIRE CONSTRUCTION DOCUMENTS- IF THERE IS A CONFLICT BETWEEN THE INSTALLATION AND MAINTENANCE MANUALS AND THE CONSTRUCTION SANITARY SEWER SYSTEM OR TO SCUPPERS. DAMPERS. 2.11 CONTROLS DOCUMENTS, THEN THE MECHANICAL CONTRACTOR SHALL SUBMIT' A E THE MECHANICAL CONTRACTOR SHALL INSULATE EACH M. ALL DUCT SHALL MEET THE FOLLOWING CONSTRUCTION A THE MECHANICAL CONTRACTOR SHALL PROVIDE ALL REQUEST -FOR -INFORMATION TO MECHANICAL ENGINEER OF RECORD. CONDENSATE DRAIN LINE WITH ONE-HAL F (12) INCH REQUIREMENTS' CONTROLS AND SUB CONTRACT TO THE ELECTRICAL ARMAFLEX WHEREVER THAT CONDENSATE DRAIN LINE IS CONTRACTOR ALL CONTROLS POWER AND TRANSFORMERS B. VIBRATION ISOLATION: THE MECHANICAL CONTRACTOR SHALL PROVIDE ROUTED WITHIN THE STRUCTURE OR THE CONDENSATE MAY SUPPLY DUCTWORK (UPSTREAM OF ANY VAV): 20 TWO POSITIVE STATIC NOT IDENTIFIED IN THE ELECTRICAL PORTION OF THE VIBRATION ISOLATION AS RECOMMENDED BY THE MANUFACTURER(S) OTHERWISE CAUSE DAMAGE PRESSURE AND VELOCITIES LESS THAN Z500 FPM. CONSTRUCTION DOCUMENTS. AND/OR REOUIRED BY MECHANICAL ENGINEER OF RECORD TO ENSURE QUIET OPERATION OF THE MECHANICAL EQUIPMENT. NO UNDUE VIBRATION F. THE MECHANICAL CONTRACTOR SHALL CLEARLY LABEL ALL SUPPLY DUCTWORK (DOWNSTREAM OF ANY VAV): 1.0IWG POSITIVE B. THE MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR OR SOUND SHALL BE TRANSMITTED TO THE STRUCTURE OR ANY OCCUPIED CONDENSATE DRAIN LINES TO INDICATE CONTENT AND STATIC PRESSURE AND VELOCITIES LESS THAN 1OW FPM. DETERMINING WHAT IS REQUIRED TO INCORPORATE NEW SPACES WITHIN THE STRUCTURE. DIRECTION OF FLOW. MECHANICAL EQUIPMENT AND CONTROLS INl U THE EXISTING C. FILTERS: THE MECHANICAL CONTRACTOR SHALL PROVIDE FILTER RACKS • ALL OTHER RETURN DUCTWORK: 1.0 NVG NEGATIVE STATIC PRESSURE AND VELOCITIES LESS THAN 1600 RPM. CONTROL SYSTEM(S) AND INCLUDING ALL COSTS ASSOCIATED WITH INCORPORATING NEW MECHANICAL EQUIPMENT AND BASIC DUCTWORK MATERIAL REOUAENENTSI FOR THE MECHANICAL EQUIPMENT AS REQUIRED. THE FILTER HACKS 2.07 ROOF MOUNTED EQUIPMENT CONTROLS INTO THE EXISTING CONTROL SYSTEM(S) IN HISMER SHALL BE INSTALLED SUCH THAT SUFFICIENT CLEARANCES ARE PROVIDED ALL EXHAUST AND OUTSIDE AIR DUCTWORK: 1.0IWO POSITIVE OR BID. THE CONTROLS CONTRACTOR SMALL PROVIDE A SUPPLY/RETURN: FOR MAINTENANCE AND SHALL BE SEALED AIRTIGHT. THE MECHANICAL A. THE MECHANICAL CONTRACTOR SMALL SET EACH ITEM OF NEGATIVE STATIC PRESSURE AND VELOCITIES LESS THAN 1600 RPM. COMPLETE DESCRIPTION OF THE ENTIRE CONTROL SYSTEM, CONTRACTOR SHALL PROVIDE A TOTAL OF THREE (3) COMPLETE TE SETS OF ROOF -MOUNTED MECHANICAL EQUIPMENT ON A FACTORY INCLUDING SCHEMATIC DRAWINGS. ❑ SHEET METAL FILTERS FOR ALL MECHANICAL EQUIPMENT N THE SIZE AND ARRANGEMENT CURB, CURB ADAPTER, OR ON A MINIMUM OF FOUR (4) PHP ALL TRANSFER OUCTWORK. 0.5TING POSITIVE OR NEGATIVE STATIC ®DUCTBOARD RECOMMENDED BY THE MANUFACTURER THE FILTERS SHALL PROVIDE SYSTEMSOESIGN MODEL RTU-20 EQUIPMENT SUPPORTS AT PRESSURE AND VELOCITIES LESS THAN 5W FPM. C THE MECHANICAL CONTRACTOR SHALL PROVIDE A HONEYWELL. ASHRAE FILTRATION EFFICIENCY AS SHOWN ON THE CONSTRUCTION THE HEIGHT REQUIRED BY TABLE 1509.7 OF THE FLORIDA MODEL T350 PROGRAMMABLE THERMOSTAT WITH A REMOTE DOCUMENTS OR 30% ASHRAE FILTRATION EFFICIENCY (MERV 6) IF NO BLALOING CODE UNLESS, OTHERWISE NOTED ON THE ANY OTHER DUCTWORK: REFER TO SMACNA "RVAC DUCT CONSTRUCTION SENSOR AND A LOCKABLE COVER FOR EACH NEW AND FXHAUST/OUTSIDE AIR: HIGHER VALUE IS SPECIFIED. CONSTRUCTION DOCUMENTS_ STANDARDS". EXISTING MR CONDITIONING SYSTEM. THE MECHANICAL ® SHEET METAL D. THE MECHANICAL CONTRACTOR SHALL. PROVIDE ALL STARTERS, ALL RECTANGULAR METALLIC DUCTWORK SHALL BE SHOP CONTRACTOR SHALL ALSO PROVIDE ONE (1) PERSONAL DIGITAL ASSISTANT (PDA)AND HONEVWELLS THERMOSTAT ❑ DUCTBOARD CONTACTORS, RELAYS, CONTROLS, AND ACCESSORIES NECESSARY TO FABRICATED OF GALVANIZED STEEL SHFFTS. FOLLOWING ARE THE INTERFACE MODULE AND PROGRAMMING SOFTWARE THE PROVIDE A COMPLETE AND WORIONG POWER AND CONTROL SYSTEM FOR SMACNA RECOMMENDATIONS FOR GAUGES AND SEAMS. CONFORM MECHANICAL CONTRACTOR SHALL COORDINATE THE INITIAL THE MECHANICAL EQUIPMENT WITHIN THE SCOPE OF WORK. THE TO THE RECOMMENDATIONS OF SMACNA AS TO SEAMS. JOINTS, OCCUP R OCCUPANCY SCHEDIAE(S) AND PROGRAMMBM WITH THE NOTES: ELECTRICAL. CONTRACTOR WILL PROVIDE ALL DISCONNECT SWITCHES, CROSS BREAKS AND TRANSITIONS, ETC. ANDYPROVIDE TRAINING P . ALL REQUIRED. ALL OWNERPROGR ® UTILIZE MATERIALS ABOVE UNLESS NOTED OTHERWISE ON PLANS CONDOR, AND WIRING FOR THE MECHANICAL EQUIPMENT WITHIN THE SCOPE OF WORK. ALLL ELECTRICAL WORK SHALL COMPLY WITH THE SHALL COMPLETED USING WELL'S THERMOSTAT PROGRAMMING SOFTWARE. ® CONTRACTOR TO PROVIDE DEDUCTIVE COST ALTERNATE FOR USE OF REQUIREMENTS OF THE NATIONAL ELECTRIC CODE. THE MECHANICAL. RECTANGULAR STEEL DUCT GAGE DUCTBOARD CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROPER OPERATION OF DUCT WITH FLATS' SLIP WITH STANpING 5' SLIP D. EACH SENSOR SHALL HE INSTALLED AT 4'6' ABOVE THE THE COMPLETE SYSTEM AND STALL ENSURE THAT WING DIAGRAMS ARE DIAMETER IN INCHES ON S SPACING GA ON 5 SPACING GA ( ) ( ) FINISHED FLOOR UNLESS OTHERWISE NOTED THE PROVIDED D I THE GENERAL CONTRACTOR NO WIRING OF ANY KIND SHALL I BE EXPOSED IN FINISHED AREAS. AL CONSTRUCTION DOCUMENTS. THE MECHANICAL CONTRACTOR SHALL COORDINATE THE EXACT LOCATION OF EACH SENSOR BASIC CD. MATERIAL REOUNRENENTS � 0 - 12 26 26 B WITH THE OWNER AND SUBMIT THE PROPOSED LOCATION TO E- HOUSEKEEPING PADS: THE. GENERAL AND MECHANICAL. CONTRACTORS 13 - 14 24 26 B MECHANICAL ENGINEER OF RECORD FOR APPROVAL. THE CONDENSATE DRAIN: SHALL PROVIDE A 4' MGM CONCRETE HOUSEKEEPING PAD UNDER ALL MECHANICAL EQUIPMENT, UNLESS OTHERWISE NOTED ON THE 15 - 18 22 265 19 - 20 20 26 C MECHANICAL CONTRACTOR SHALL PROVIDE COORDINATION OF ALL SENSOR FINISHES WITH ROOM FINISHES AT NO ADDITIONAL ® SCHEDULE 40. PVC CONSTRUCTION DOCUMENTS. THE HOUSEKEEPING PAD SHALL. EXTEND P BEYOND THE 21 - 26 18 26 C COST TO THE OWNER. ❑ COPPER, TYPE L. WIARMAFLEX INSULATION MECAMCAL EQUIPMENT ON ALL SIDES. 27 - 28 16 26 C E ELECTRIC DUCT HEATERS: ELECTRIC DUCT HEATERS SHALL BE 29 - 30 16 26 D E. ALL EXHAUST AND OUTSIDE AIR FANS SHALL INTERLOCKED WITH THE AIR HANDLER SERVING THEEASSOCIATED SPACE. NOTES: UNDERWRITERS` I ABOIA I DRIES LISTED, BEAR THE SILL OR MARK OF AN 31 - 36 - 240 ®1JQ117'F MATERIALS ABOVE UNLESS NOTED OTHERWISE ON PLANS APPROVED TESTING AGENCY. AND BE EQUIPPED WITH AN APPROVED. 37 - 42 - 24 E F. ALL 120-VOLT RESTROOM EXHAUST FANS WITH ELECTRICAL AUTOMATICALLY RESETTING OUTLET AIR TEMPERATURE LIMIT CONTROL 43 - 60 - 22 G REQUIREMENTS OF UP TO SIX WATTS SKILL BE CONTROLLED THAT WILL LIMIT THE OUTLET AIR TEMPERATURE TO NOT MORE THAN 20mv BY AN OCCUPANCY SENSOR WITH A TIME DELAY. THE INITIAL THE MECHANICAL CONTRACTOR AND MANUFACTURER SMALL EQUIP THE STANDINGS' SLIP STANDING TIME DELAY SHALL BE SET AT TWENTY (20) MINUTES ELECTRIC ELEMENTS OF THE HEATER WITH FUSIBLE LINKS ORA MANUAL RESET TEMPERATURE CONTROL THAT WILL PREVENT THE OUTLET AIR SIZE G THE MECHANICAL CONTRACTOR SHM.I PROVIDE A THE CLOCK INSULATION MATERIAL REQUEEIbENTSI TEMPERATURE FROM EXCEEDING 25(PF. EACH ELECTRIC DUCT HEATER FOR ALL OUTDOOR AIR FANS THE MECHANICAL CONTRACTOR SHALL BE INTERLOCKED WITH THE ASSOCIATED MR HANDLER TO ENSURE B 1' x 26 GA SHALL COORDINATE THE INITIAL OCCUPANCY SCHEDULE(S) ON CONCEALED DUCTWORK. ELECTRIC DUCT HEATER SHUTDOWN IN THE EVENT OF AN AIR HANDLER FAN C 1'x 22 GA AND SETTINGS WITH THE OWNER AND PROVIDE TRAINING AS ®FLEXIBLE FIBERGLASS FAILURE. D 1-1/6' x 22 GA REQUIRED. E 1-I18' x 18 GA ❑ FIBROUS DUCTBOARD G 1-5/8' x 18 GA Os .Rae N: sea 1.s 1 .Da REFER TO SMAGNA TABLES FOR REINFORCEMENT FOR DUCT LENGTHS ON EXPOSED DUCTWORK- OTHER THAN FIVE (5) FEET. ❑ FLEXIBLE FIBERGLASS G L� B A L ALL ROUND RIGID METAL DUCTWORK CAN BE PREFABRICATED OR SHOP FOLLOWING ARE THE SMACNA RECOMMENDATIONS FOR al FIBROUS DUCTBOARD S�NCu c- C GAUGES AND SEAMS. ELBOWS SHALL. HAVE CENTERLINE RADIUS OF 1-1/2 TIMES DUCT DIAMETER. THE CONTRACTOR MAY PROVIDE EQUIVALENT INCFABRICATED. R-VALUE: ROUND OR RECTANGULAR DUCT AS CONDITIONS AND SPACE PERMIT. ® IN UNCONDITIONED SPACE, R-8 M E P F ENGINEERING © ALL OTHER DUCTWORK, R-4.2 IN FOPGLOBAL-SANCHE2.COM CA4'': 6237 NOTES: 816 MANATEE AVE. E, SUITE 16 ® UTILIZE MATERIALS ABOVE UNLESS NOTED OTHERWISE ON PLANS BRADENTON, FL 34208 PHONE: 941-75B-2557 1CG7 -ND E RGON CLVD.. SUITE 103 TAMPA, FL 33629 PHONE: B13-281-0001 C&K ARCHITECTS I INTERIORS - MW!ur -kft m design. tlicnt n iM AACOO16- 4221 WEST BOY SCOUT RI VD., SUIIE 150 TAMI'A, FL 33607-5743 813.8B4.2000 280 WEST CENTRAL AVE. WINTER HAVEN, FL 33880-2957 863.577.2054 s\� A. sF N o. 71454' i t, A 7 t * -A X 5/14/2021 j,* CO.. STATE OF ' Nv Fs � ORIDP+ Q;' S70NAL E� E'I'l, i 9 EE QJ/ Ii O Z W 44 •. J d U 0 Z 0 2 pp U ao Lu m P MD BAI®Fm PERMIT FMOIBCTRWYBI 21020 DATE 5.5.21 Dullim IMMOH mo 1 � C&K ARCHITECTS I INTERIORS 4221 WEST BOY SCOUT BLVD.. SUITE 150 813-884.2000 280 WEST CENTRAL AVE. WINTER HAVEN. FL 33880-2957 CL LLI CL Lu PERMIT mosmNwmm 21020 5.5.21 M2.1 PRESSURIZATION CALCULATION ITEM EXHAUST (CFM) MAKE-UP (CUM) OA (CFM) HOOD 1 3150 2550 - RESTROOMS AND JANITOR 140 - DISHWASHER HOOD NONE NONE NONE RTU-1 AND RTU-2 - - 940 TOTALS 3290 2550 940 TENANT PRESSURE = 940 OA FROM HVAC UNITS •2550 MAKE-UP - 3290 EXHAUST FROM AND RESTROOM = 200 CFM (POSITIVE) til}3 345 CFM 1 J ® ® I RTU T5TON EFI 8'0 220 RA D1J($T UP TO I 220 CFM RTU-$ III 70 CFM D .. 8 L r 345 CFM e2 ,1-1/4- GO CONNECT TO TO CFM FNJ \ �XISTIN( ROOF DRAIN c I 8'0 EA DUCT CONNECTO TO EXISTING EXHAUST TERMINATION 6 N MECHANICAL PROPOSED PLAN 0 2' 4' SCALE: 1 /4' = 1'-0' AREA OF WORK Ili KEY PLAN SCALE: NOT TO SCALE �GLOBAL n��IEvC SANC MEPF,,,,,,Il ENGINEERING INrB@GL00AL BANCNE2. coM CAI: 6237 81 6 MANATEE AVE. E. SUITE 18 BRAOENToN, FL 342D8 PHONE: 941-758-255 I 3B25 HENOERs.. 8"... BUTTE 103 TAMPA. FL 33629 PHONE: a13.281-DOO1 1p C&K ARCHITECTS I INTERIORS lfrhrte m-inlndprdesign.dlenl services ne Cnelezn 4221 WEST BOY SCOUT 81 VD., SUITE 150 IAMPA. R 336U7-5743 813-884-2000 280 WEST CENTRAL AVE. WINTER HAVEN. R 33880-2957 863.5//-2054 : No. 71454 i • A15/14/2021?W 0 St, STATE OF . 4, 3/0N AL F'N - TR .-c i _J x qz J O o O Lu :n O Oa co > S O Q N N U Q Q co m U w P 851i®fOt PERMIT AOI[Ci Numm 21020 Don 5.5.21 DUWrc WWtR } M4.1 I!'IIII i 1 I I I _L_ I __3_ I If I I I I _ I 1 1 I- 1 1 11 1 1. 11 11 1 -. '.I I I I 111T - .. I .. _ 1 11 1 11 'I I I' II 11 I 1 1 1 1 '71I_'L:!I EXHAUST FAN SCHMULE MARK EF-1 EF-2 MANUFACTURER GREENHECK GREENHECK MODEL - - - - SP-R110 SP-8110 CFM 70 70 E.S.P- (IN. W.G.) 0.5 0.5 FAN TYPE CEILING CEILING MOTOR SIZE (WATTS OR BHP) SOW BOW ELECTRICAL (V/PWHZ) 115/1I60 115/1/60 SOUND (SONES) _ 2 2 _ WEIGHT (LBS) 10 10 SERVICE WOMENS 104 MENS 105 QUANTITY _ _ 14 - _- 1 CONTROLS INTERLOCK INTERLOCK WILIGHT SWITCH W/LIGHT SWITCH NOTES 1 2 3 4 5 6 1 2 3 4 5 6 NOTES OPROVIDE FLEXIBLE CONNECTORS AT ALL DUCT CONNECTIONS TO FAN. OPROVIDE FAN WITH GRAVITY BACKDRAFT DAMPER. OPROVIDE WITH FACTORY MOUNTED DISCONNECT SWITCH OPTION. OPROVIDE FAN WITH SPEED CONTROLLER. MOUNT SPEED CONTROLLER IN 2X4 METALUC BOX ADJACENT TO FAN IN CEILING. TEST AND BALANCE CONTRACTORS SHALL ADJUST FAN PERFORMANCE THROUGH USE OF SPEED CONTROLLER. (DPROVIDE FAN WITH ADJUSTABLE TIME DELAY RELAY FOR FAN TO CONTINUE TO OPERATE WHEN SWITCH IS OPENED. OPROVIDE WITH CFL LIGHT OPTION. AIR SYSTEM SIZING SUMMARY FOR RTU-1 Air System Information Air System Name RTU-1 Number of zones 1 Equipment Class PKG ROOF Floor Area _ 804.0It Air System Type SZCAV Location _ _ _ _ Tampa, Florida Stang Calculation Information Calculation Morth. Jan to Dec Sizing Data _ Calculated Central Cooling Coil Sizing Data Total Cal bad _ _ 4.8 Tons Total call bad 57.5 MBH Sensible cal bad _. 37.0 MBH Coil CFM al Jun 1500 -1638 CFM Max block CFM 1638 CFM Sum of peak lone CFM _. _ 1638 CFM Sensible heat ratio 0.643 fl°/T- 167.9 BTLY(Ilrfl') 71.5 Wain flow Q 10.0 -F rise WA Central Hosting Coil String Data Max coil load 23.8 MBH Cod CFM at Des Htg ___ __ 1838 CFM Max coil CFM 1636 CFM Water flow ® 20.0 `F drop _. _ WA Supply Fan Sizing Data Actual max CFM 1638 CFM Standard CFM 1637 CFM Actual Max CFM/n' 2.04 CFMrW Outdoor Ventilation Air Data Design sallow CFM -. 267 CFM CFM/fP 0.33 CFMM' Zone CFM Slang _ Sum of apace airflow rates Space CFM Sizing _ Individual peak space loads Load acwrs at _ Jun 1500 OA DB / WET _ 89,0180.0'F Entering DS I WB 78.2167.7'F Leaving OB/WB - 57.315SAF Cod ADP _ 55.0'F Bypass Factor 0.100 Resulting RH _ - _ _ 55 % Design supply temp. ._ 56.0'F Zone T-sbt Check 1 call OK Max zone temperature deviation 0.0'F Load occurs at DesHLg BTUI("R) 20.5 EnL DB / Lvg DB .. 63A I T7.0 -F Fan motor BHP _-._ _. 0.00 BHP Fan motor kW 0.00 kW Fen static - 0.00 in wg CFMIpw an 14.06 CFMlporson At Sizing Calculation Information Calculation Mwdis Jan to Dec Sizing Data _Calculated Central Cooling Coll Sizing Dats Total wd load _ 7.1 Tons Total wi load __ 85.6 MBH Sensible col bad 58.1 MSH Cod CFM al .lun I.W 2610 CFM Max Node CFM 2610 CFM Sum of peak zone CFM 2610 CFM Sensible heal ratio __ 0.6'79 R'/Tw _ 109.2 BTUI(hrfl') 109.9 Water lbw @ 10.0 -F naa WA Central Nesting Coil String Date Max Call load -_ _ _ 24.6 MBH Cog CFM at Das- Hig _2610 GEM Max coil CFM 2610 CFM Water flow @ 20.0'F drop WA Supply Fan Sizing Data Actual max CFM _ _. _ _ _ 2610 CFM Standard CFM _. _ 2609 CFM Actual max CFM/IF 3.35 CFMM' Outdoor Ventilation Air Date Design sallow CFM 150 CFM CFM1W _ 0.19CFMNe Air AR DISTRIBUTION SCHML LE MARK FACE SIZE NECK SIZE MATERIAL ACCESSORIES FINISH MANUFACTURER AND MODEL NOTES SD-1 SD-2 24X24 24)(24 6-0 8'0 ALUMINUM - - TITUSTMS-AA 9 ow ALUMINUM - - - - - - TITUSTMS-AA TITUS•TMS-AA CKDO 3 ow SD-3 SD-4 24X24 24X24 10'0 12'0 14'0 ALUMINUM ALUMINUM ALUMINUM - - - TITUSTMS-AA TITUS-TMSAA TITUSTMS-AA TITUS-50F TITUS-50F TITUS-WF 3 ow SD-5 SDS1 24X24 coo 12X12 610 22X22 22X22 ALUMINUM ALUMINUM ALUMINUM ALUMINUM - - - - 3 ow 2 3 2 3 00 24X24 - - - LT.,E- 24X24 24X24 I 22X22 NOTES OFLEX DUCT SIZE TO MATCH NECK SIZE. MINIMUM LENGTH OF FLEX SHALL BE 6`4r TO MAXIMUM LENGTH OF 10'-0', BALANCE OF DUCT SHOWN ON PLAN SHALL BE RIGID STEEL DUCT SAME SIZE AS NECK SIZE, EXTERNALLY INSULATED. OPROVIDE RUNOUT BRANCH DUCT TO AIR DEVICE SAME SIZE AS AIR DEVICE NECK UNLESS OTHERWISE NOTED ON PI. ANS. PROVIDE O.B.D. MODEL # AG-15-AA FOR AIR DEVICES IN HARD CEILING. OCOORDINATE COLOR AND FINISH PER ARCH. DRAWINGS, REFER TO SHEET A100 NOTE -F AR SYSTEM SIZING SUMMARY FOR RTU-2 Air System information System Name __ RTU-2 Number of zones 1 F_gripment a- PKG ROOF Floor Area 779.0 W r System Type SZCAV Location Tampa, Florida Zone CFM Sing B3 of apace airnow rates Space CFM Sizing Individual peak space loads Load occure at Jun 1500 OA DB/WB 99.01$0.0'F Entering DB I WET _. _ ... 77.0166.3'F Leaving DB / WET 56.3155A'F Cod ADP _- _. 54.0'F Bypass Factor 0.100 Resulting RH _. 56 % Design s "'y temp. _ 58.0'F Zeta T-sta1 Chac* _ 1 of 1 OK Max zone temperatre deviation 0.0'F Load occurs at Des Htg BTUI(hr8') 31.6 Ent DB I Lvg DB 67.9/76.6'F Fan molar BHP 0.00 BHP Fan motor kW 0.00 kW Fan static __ 0.00 in wg CFM/persIM _. 25.07 CFWpenson ROOFTOP UNIT SCHEDULE MARK MANUFACTURER MODEL TOTAL COOLING CAPACITY SENSIBLE CAPACITY - - - RTU-1 LENNOX KCB060S4B RHIU-2 LENNOX KCB09OS4B BTUH STUH 61.800 41.100 1750 93.600 64.500 2625 SUPPLY AIR CFM OUTSIDE AIR CFM - - 375 565 ENTERING AIR TEMPERATURES DBNVB;F 76.6166.8 78.6166.8 LFAVING AIR TEMPERATURES DBIWB;F 55.8/54.9 54.9/54.8 E.S.P. ELECTRIC HEAT - � IN. W.G. _-KIN -� 0.5 - - 11.3 0.75 16.9 - ELECTRICAL CHARACTERISTICS MCA MOCP SEER/EER WEIGHT NOTES V/PWHZ A 208060 45.0 45 14.0 SEER - -� 208/3/60 69.0 70 12.9 EER --1235-- - A - LOS - 00 3 4 5 1 2 3 4 O5 NOTES OUNIT CONTROL SHALL BE BASED ON SPACE TEMPERATURE AND UNIT SHALL BE CAPABLE OF HUMIDITY CONTROL. PROVIDE WITH HOT GAS REHEAT COIL OPTION. UNLESS VALUE ENGINEERED BY THE OWNER OPROVIDE GALVANIZED STEEL FILTER FRAMES AND MEDIA IN UNIT FILTER WITH MEDIA. FRAMES SHALL BE PRE -MANUFACTURED (NOT FIELD FABRICATED)_ FILTER 9HAL.L BE MERV 8. OPROVIDE HIGH EFFICIENCY MODEL WITH FACTORY ROOF CURB, OUTSIDE AIR INTAKE WITH 3 MOTORIZED DAMPER AND BIRD SCREEN AND THRU-THE BASE ELECTRICAL CONNECTION. OPROVIDE WITH FACTORY THERMOSTAT WITH REMOTE SENSOR UNIT SHALL CYCLE GOOUNGIHEATING FROM THEIR THERMOSTAT OR SENSOR. COORDINATE TSTAT & SENSOR LOCATIONS WITH OWNER PRIOR TO INSTALLATION. OPROVIDE WITH FACTORY INSTALLED ELECTRIC HEATER, SINGLE POINT POWER CONNECTION AND 5 FACTORY DISCONNECT. DUAL POWER WILL NOT BE ACCEPTED. VENTLATION SIZING SUMMARY FOR RTU-1 1. Summary Ventilation Sizing Method _ _ ASHRAE Slid 62.1-2010 Design Condition .. _ Coating operation Occupant Diversity (D) -... - 1.000 Unconecied outdoor Air Intake (Vou) 263 CFM System Ventilation EfBciarlcy (Ev) OJIS3 Outdoor Air Intake (Vol) 267 CFM 2 V4mtilation Analysis Time People Breathing Space Floor Am Outdoor Averaged Outdoor Air Air Space Zone Outdoor Space Supply Air Arse Air Rate Occupancy Rate DiaMkutlon Outdoor Alt Air Ventilation CFM C Oltc rib CFM/In- ERective- CFM CFM Emrdan Name Name MWL (VTR) (Az) me) (Pz) (Rp) ( ea) (Vbz) vz) 1 RRIDOR rOFRCE 1 218 16110 0.06 0.0 0.00 1.00 10 10 1.114 _ NING AREA 1 1387 619.0 IS IN 7.50 1.00 246 246 0.983 1 35 17.0 0.06 1.0 5.00 1.00 6 B 0.987 _ s nd Multipliers) 1638 _ 263 0.963 VENTILATION SIZING SUMMARY FOR RTU-2 1. Summary VentYaOran Suing M.1hod _ ASHRAE Std 621-2010 Design Condition _ _. Healing operation Occupant Diversity (D) 1.000 Uncorrected Outdoor Air Intake (Vou) 138 CFM System Ventilation Emd-cy (Ev) _ _ 0.920 Outdoor Air Intake (Vol) 150 CFM 2. Verdlisllon Analysis Time People Breathing Space Floor Ana Outdoor Averaged Outdoor Air Air Space Zone Outdoor Space Supply Air Ana Air Rate Occupancy Rate Distribution Outdoor Air Air Ventilation c cF ElTactiverneee CFM CFM Efficiency Zone Nance/ Name Mail. (VP4 (Az) IRS) (p.) (Rp) (E, (Vea) (�) (E-) Zone 1 465.0 0.12 SERVICE 1 690 20 7.50 0.80 91 73 0.920 KITCHEN 1 1920 294.0 0.12 4.0 7.50 0.80 82 65 1.011 ebb Ind. Mud 2610 138 0.220 MECHANICAL SCHEDULES SCALE. NOT TO SCALE 09 JOB I: SO71.21.00 GLOBAL S crlr-7LI MEPF ENGINEERING IN FO(q)DLDBAL-9ANCHEZ . COM CA#: 6237 S 1 6 MANATEE AVE. E, SMITE 1 B BRADENTON, FL 3420E PHONE: 94 1-758-255 1 3825 HENDERSON BLVD.. SUITE 103 TAMPA. FL 33629 PHONE: B13-2B1-0001 C&K ARCHITECTS I INTERIORS archile t ue-kserior design. diern servicee 4221 WEST BOY SCOUT BLVD., SUBS 150 TAMPA. N. 33607-5743 813.884.7000 290 WEST CENTRAL AVE. WINTER HAVEN, Fl .3.31180.2957 863.577.2054 FS� A. Sf� ar fr+� jCE NS�-f! No. 71454' A . 5/14/2021 0 \ STATE OF j ru S7ONAL V_ i if N W Cn O W 2 � U� c„ m 9O a-O LU _U Z Q m U � W m 4 M 10 to to 0T11®Tpk PERMIT ?*OLEO Mao 21020 DAR 5.5.21_ _ oatMcImim M 7.1 HOOD NO TAG MODEL UFACTUR LENGTH MAX COOKING TEMP TYPE APPUANCF DUTY DESIGN CFM/FT TOTAL EXH CFM EXHAUST PLENUM TOTAL SUPPLY CFM 14000 CONSTRUCTION HOOD CONFIG END TO END ROW WIDTH LENG HEIGHT DIA CFM VEL SP 1 KH-1 5424 FX-p-PBp-F FCON-AR W(r 600 DEG I HEAVY 225 31SO 4' 14' 1575 1473 -0.395' 2550 430 55 WFERE EXPOSED ALONE ALONE 4' id- 1575 1473 -0.395 FlRE HOOD HOOD FIRE SYSTEM ELECTRICAL SWITCHES NO TAG TYPE OTY H/EIGHTY LENGTH EFFICIENCY@ 7MICRONS OTY TYPE WIRE LOCATION SIZE SYSTEM N UAR TYPE SIZE MODELM OUANTITY PIPING WEIGHT 1 LIGHT I'll, 1 KH-1 SS BAFFLE WITH 11/WOLES 10 18- 18- 30% 7 L55 SERIES E28 NO RIGHT 12'k54'x74' ANSUL R702 3.N3.0 SG321110FP 1 FAN YES vnnn norvrn Aro HOOD NO TAG OPTION FIELD WRAPPER 18,00' HIGH FRONT, LEFT, RIGHT. 1 KH-1 BACKSPLASH S0.00' HIGH X 180.00" LONG 43O SS VERTICAL, RISER SENSOR INSTALL 31N DBL. HOOD NO TAG POS LENGTH WIDTH HEIGHT TYPE WIDTH LENG DIA CFM SP 1 K14-1 Front 180' 16' 6' MUA 1T 28- 819 0.230' MUA 12. 28' 849 0.230' MUA IT TB- 849 1 0.230' wv"ArTv'r PIA rArNIARMATTrHA _ TrIPIAARryf00 FAN UNIT TAG QTY FAN UNIT MODEL# MANUFACTURER CFM ESP RPM MOTOR HP BHP PHASE VOLT FLA DISCHARGE WEIGHT SONES NO ENCL VELOCITY (LBS) 1 KEF-1 1 EARDUIS ECON-AIR 1575 1.000 1 1195 ODP 0,750 0.4880 3 206 2.5 498 FPM 122 128 2 KEF-2 1 FABOUIS ECON-AIR 1575 1.000 1 1195 GOP 1 0.750 0.48W 3 1 208 25 498 FPM 122 12.8 MTTA PAAT TArPAQA/ATTATV - _TARLAAR71 AA FAN MIN MIN DESIGN MOTOR WEIGHT UNIT TAG OTY FAN UNIT MODEL It BLOWER HOUSING CFM CFM ESP RPM ENCL HP BHP PHASE VOLT FLA MCA MOCP (LBS) SONES NO 1 3 KSF-1 I 1 EA-A1-.10 G10 Al - 2. 1 0.. 913 ODP ISM 0.8780 3 208 4.8 5-SA 1 245 - FAN UNIT TAG OTY OESCRIPRON NO I GREASE BOX 1 KEF-1 1 2 YEAR PARTS WARRANTY- 1 GREASE BOX. 2 KEF-2 1 2 YEAR PARTS WARRANTY. 1 GRAVITY BACKDRAFT DAMPER FOR SIZE 1 HOUSING. 3 KSF-1 1 12 YEAR PARTS WARRANTY. PIA7 Ar V.0ADTDO FAN EXHAUST SUPPLY UNIT NO TAG GREASE CUP GRAVITY DAMPER WALL MOUNT SIDE DISCHARGE GRAVITY DAMPER MOTORIZED DAMPER WALL MOUNT 1 KEF-1 YES 2 KEF-2 YES 3 KSF-1 I I I YES NO ONN FA TAG WEIGHT ITEM SIZE 1 II1 KEF-1 41 LBS CURB 23.00011f X 23.000'L X 24.000'H VENTED HINGED. 2 9 2 KEF2 41 LBS CURB 23.000-W X 23.00TL X 24.000-H VENTED HINGED. 3 1113 KSF-1 34 LBS CURB 21.000-W X 21.000'L X 24.000-H . FEATURES: RD« M«N1m FA16 -rasrwxunl9rooEL r,.�aas Aa wmFnro -wnnsu clan NOTDa m dsal9r<cr - li fiAFEIY dR(xnaEr.T RVATM OPER.EIgN 91e'F I1+aC} -[alFA9 UAS9x211xn IL^u11M8 UmknLL FnR PMIe IwVE f9FACHEO TIIER VL Ed149aVM. NO n9HIXRAMI' UFIkIar)rGIYW KFEG18 TO 111E FAN WNCH veal. uulru1s1s10erwANo gssv vnFORs nr sucF plrclFoanaoaponF +s Awules w9mlwr nE FAI9 a cww 11AhAA64D ru ANY DnnXr T1wr cdan dweE gwA6c wxxlxaa cxa:aa: aox Aere WAARANTV FEATURES: µTafrED­G. -Tex NW UE162A1®Ulf. g616. a-- --WTOR TO OIBL'«l1Er. T -TM A-elT�l - gaCONHEGi gnTCH - AT Ix'FnAlmHam nlwOH -n1fAv n.Asarxwlxn T®nxn II1rLL TFar EowusT FAN MlerorFlwTF rnanrXAxxu Y YYrlf WaIIBTWDAM Ai 900'F 11aYC) Ue111 nLL FNI PARTS IwVE 1MAC1® 11EMIK EaaIBPAxr, AND 1MTNaT ANY n6 rFaueara96 Ls66c1s To TIE FAIuwucH w«xu anl><uusAr [ uw.ERTmra ARN(1F I FVJIELV ILgI E%1W9g1 fANMar lxilNt[ CWIMUDIR[Y V 60NG W11OaNF CgEA1E VMtx6 a96'cI WSRAI'Elet119« WTXXIr TIE FAM IF«AaNG oA61A®To w7+FxrPHr mnr rxxa n rxaF 611En6E ecxewc NIOnIRe WMPAMY. VENTEO cum. 0� HEEL NOIX-OPEMNC zz lrz aMENSKX6s. II12 PIT.ED CURBS ARE AVNEABLC FOR PITCHED R(XRE 5- SPE(SY STU E. 12- EXAMPLE' 7112 PITCH = 30- SLOPE. WNTEO CURB. 0 OAUGE TFEL 4 _ , nOOF.oPENINc zz trz IIWENBIONB. II 1R VON Nr HLOCUR SAKE R ARE AVNAN LF 0- Ha1PID S' SPEaFY PITCH, 1 EXAMPLE 7112 PITCH =So' SLOPE. BLOWER PITCHEDCURBS5ARCAVNLAaE SAKE. / IP FOR PITCHED 0' SPFC!" PITCH 1 EXAMPLE: 1112 RrCll • 70' SLOPE, 0 0 O 0 O FAN 93 EA-Al-G10 - SUPPLY FAN (KSF-1) 1. UNTEMPERED SUPPLY UNIT WITH 10' BLOWER IN SIZE 81 HOUSING. 2. INTAKE HOOD WITH EZ FILTERS. 3. DOWN DISCHARGE - AIR FLOW RIGHT-> LEFT. 4. GRAVITY BACK DRAFT DAMPER, 16' WIDE X 18' HIGH. STANDARD GALVANIZED CONSTRUCTION, 1 1/4' REAR FLANGE, FOR SIZE 1 UNTEMPERED FAN HOUSING (5181). 6.2 YEAR PARTS WARRANTY. 'NOTE: SUPPLY DUCT MUST BE INSTALLED TO MEET SMACNA STANDARDS. A MINIMUM STRAIGHT DUCT LENGTH MUST BE MAINTAINED DOWNSTREAM OF UNIT DISCHARGE AS OUTLINED IN AMCA PUBLICATION 201. WHEN USING RECTANGULAR DUCTWORK, ELBOWS MUST BE RADIUS THROAT, RADIUS BACK WITH TURNING VANES. FLEXIBLE DUCTWORK AND SQUARE THROAT/SQUARE BACK ELBOWS SHOULD NOT BE USED. ANY TRANSITION AND/OR TURNS IN THE DUCTWORK WILL CAUSE SYSTEM EFFECT. SYSTEM EFFECT WILL DRASTICALLY INCREASE STATIC PRESSURE AND REDUCE AIRFLOW. DO NOT RELY ON UNIT TO SUPPORT DUCT IN ANY WAY. FAILURE TO PROPERLY SIZE DUCTWORK MAY CAUSE SYSTEM EFFECTS AND REDUCE PERFORMANCE OF THE EQUIPMENT. SUGGESTED STRAIGHT DUCT SIZE IS 14- x 14'. FIRE SIPPRESSION srsTEM Fwnldl WqN-wall, facmry SWI, grease duct fix use wTpo I kWw hoods, eldd+oonbsrm tothe requi-mutt ofNFPA-96. Producss ahe1 Be ETL listed 1.UL•1978 a ld G CANIULSB02 for vedklg ak And I/malc vapras k«n rxxrxlmldw «XdMl9 rlprlraarne 1m M:acribad'n NFPA9111. des wa .hr b. oDlMu19be d.1138 «.a7 thrx Hype slubdeae sled aria Da evedebb m dMlabrs e' IN«Igfl 24-. a aappena, ran eaapters. no6a Inral.Otione, tnblpn eras SERVICEAIRFLOW. expansion Jokft re Wired m k"gfMea duct xh.1 he aKAlded. r�F.m. CONNESWITCH.Rod poMtratlone sh0a w111p1y with Iaded aWrx m m11DueMhles, sme-Cbarwxa fo Cmblm8dec' guide mr deNil6 The grease dull WI bnrtlNe al Bb fan adDlaF dale. AWT13RwN be fWy woldud m lip Bin adapter pleb and do fen adaplie Ow wM l ,,, faMmmd b ft alb t16kg a suimNy.-d laalerler provldrd bytitan; Ame plW 12d Ifs OOOROperdbn CE end MlMaehohos MMad- Tor dNxpe. G.- dud pads Nall be held mpNMr by r1aMa of Iorrrled vM d..W. Bed aaeleel wlBl 3M Fae Same/ 2000.. Scnws. Imad to sedlra the - damps Y1691. d the Mx -Hand type wM IbngW skps ant bWo land m'thaadu for aaq Nrdq. Nub shall be raWled by rraMM till hee#aMkg c" m all- wy.Yp wind. Si glswa C-aae DW"be ftWW m accordnlce with the -ofi d-r-il-InOWtbn. Operation aM Mambrl«ae Marxd: ETL lWotip aM We and bpi .ties. G- el t kleleled outside of the build, 9 shall be Woleead agaarol aeeider" dana" «vandaTRrr[ Slppmt v«kcdy w.tWiad pease dud kmm Ba E Wdap WIWe uxng ngM stru(rieN upp«b. Mvdex vgaMe b Bre Wurlum 6Y waldaq «bdbrp ebal atgwnebn erxYexx w c.no ete inserts. Supp«I h«r2ontMy In MW ones drd ham ea buAdxg emxdxe using above n.Ahod. 1rt 7Ne0ded rod and aeddes may oleo d lased /« 1st auDDorl d hodnn1Y pease duct Fan. shall be supposed mdaperlOenlY I- U. W- dlua waons. Probe pease duct f . twi wg « m 0,ftd C.Aw by Ian hlrque «vibeam. __ _ Da oe • a Bo I z I ua U�� Co The DW 8errU. has bast by I Thaly wldaly r product has ben Wbd m and flea mli ant lam be tad, mMk sMirelee thatdw Canadian cia sbar agreed! f foc"ed (wnsarrR9e1 U.S and CanWlan products aaiMy Marldrd, theI Ba rna«dsdudrg site hoc been uxudlled, and Bd tlr appNranf Iw agreed b a 111nBIam d pMd9c bcmN p V n ixog G L� B A L kA-up klgXw4kA1s m v9Mfy -*..it Pxrldrma . Modal DW Sells Is ETL Listed udder Ns number 3114021 erM mmplas with UL 1970 Slaudard and CANWLG.S882. [> ��r_z I„ M MEPF ENGINCERING MECHANICAL SCHEDULES NFOC?%GLUL BANCHEZ.COM CA;6237 SCALE: NOT TO SCALE _ - - - 81 6 MANATEE AVE. E, SUITE 1 B BRADENTON. FL 34208 PH.. F:... _758-2551 3825 MENDER... BIND., SUITE 103 TAMPA, FL 33629 PHONE: 81 3-2B 1 -0001 C&K ARCHITECTS I INTERIORS erd*aawa-mbvb dasipl. diem services AAC001629 4721 WFST BOY SCOUT BLVD.. SURE 150 TAMPA, FL 3,W7-574.3 813.884 2000 280 WEST CENTRAL AVE. WINTER HAVEN. R 33880-2957 863.5//.2054 SUM A. 3F N0. 71454 p � 5/14/2021 i w O % STATE OF 24A GR10„1"+ G� SYONAL It i '^ S V5/ WW N O Fx L M�M W W� =J /rk d V '^ 0 W_ J N O U m Z m m U LLi p m b ol � - Ii41®FOC PERMIT_ 1101R.1NUMILI 21020 DAZE 5.5.21 DMNNMF NUMIB M8.1 END VANES SPUTTER VANES SHALL BE IU71 LOCATED AT ELBOW WHEEL IN BACK OF DUCTWORK R SHALL NOT BE VISIBLE \ VANE SHALL FROM POINT IN COVER ELBOW OUT W THROAT IF RAN < 1.0 PROVIDE SPUTTER VANES. THIS DETAIL APPLIES TO 90• RADIUS ELBOWS AND LESS THAN 90• RADIUS ELBOWS AND ANY RECTANGULAR DUCT LESS THAN 90•. VOLUME DAMPER VOLUME DAMPER ON bxc c RETURN DUCT ONLY. (8-b)ro DOUBLE OR axc SINGLE BLADE TURNING VANES SPUTTER DAMPER ON 12• 15• SUPPLY DUCTS ONLY (a+bpcc MAIN SUPPLY, RETURN OR EXHAUST DUCTWORK 15' FOR ALL SUPPLYIRETURN DUCT SUPPLY RETURN TO DIFFUSER BRANCHES. OR RETURN OR ©CONNECTION AT SIDE, 45• EXHAUST GRILLE TOP OR BOTTOM OF DUCT. END OF DUCT TO HAVE AIR BALANCING MINIMUM I2' ? I J MINIMUM STRAIGHT DAMPER (TYP.). STRAIGHT r?u `II IL FROM DUCT TTRAANNSMOONN y TRANSITION VOLUME DAMPER AT BRANCH TAKEOFFS (TYP.) BRANCH TURNING DAMPER VANES L RRN (TYP-) DAMPER a MAIN DUCT BRANCH o c a c v 6 046 / SUPpL� TRANSITION SPLIT IF REQUIRED TYPICAL BRANCH DUCT & NOT TO SCALE MINIMUM OF 1 SUPPORT IF DUCT IS LESS THAN 4' LONG 1;0. @1 DUCT SHOULD EXTEND STRAIGHT FOR FAO SEVERAL INCHES FROM A CONNECTION P BEFORE BENDING. SHARP BENDS ARE 6b NOT ALLOWED. l,y 1MGM 45• FITTING.—' MAXIMUM SAG 1/2• PER FOOT (41.7 mm PER m) OF SUPPORT SPACING NOTE: CLOSER MAXIMUM HANGER INTERVALS MAY BE SPECIFIED AS A CONDITION OF U.L. LISTING, PARTICULARLY IN FIRE RATED FLOOR -CEILING ASSEMBLIES. FLEXILE DUCT SUPPORTS DETAL NOT TO SCALE AS PER HVAC DUCT CONSTRUCTION STANDARDS METAL AND FLEXIBLE SMACNA - THIRD EDITION OUTSIDE AIR INTAKE FACTORY FABRICATED, / INSULATED ROOF CURB DUCT VIBRATION ISOLATION CONNECTORS TRANSITION AS REQ'D TO INLET/OUTLET OF AHU GALVANIZED HOLD DOWN STRAP 18" LONG 4X4 TREATED WOOD BLOCK E 1"THICK RIGID INSULATION ADHERED TO WOOD BLOCK PLACE RTU ON ROOF CURB. PROVIDE CONTINUOUS GASKET ON CAP OF ROOF CURB. SECURE RTU AS PER ARCHITECTURAUSTRUCTURAL DRAWINGS. I"CONDENSATE DRAIN LINE WITH TRAP. (DISCHARGE TO NEAREST ROOF RTU DRAIN) ROOF - ® ROOFNOIST CAPACITY AS PER ARCH/STRUCT ROOFTOP DETAL SCALE: NOT TO SCALE GAS/ CONDENSATE/ REFIGERANT PIPING 18• LONG 2X12 TREATED WOOD SECURED TO 4X4 WITH GALVANIZED HARDWARE PFNNO SUPPORT DETAIN. ON ROOF SCALE: NOT TO SCALE NIC MECHAAL DUALS 12. SCALE: NOT TO SCALE MECHANICAL DETALS SCALE: NOT TO SCALE GLOBAL S�Cnc�I�C MEPF ENGINEERING INFOPQ OL09AL-SANCH E- DOM CAI: 6237 B 1 6 MANATEE AVE. E, SUITE 16 BRADENTON, FL 34208 PHONE: 941-758-2551 3825 HENDERSON BLVD., SUITE 103 TAMPA. FL 33629 PHONE: 8 1 3-26 7.000 1 C&K ARCHITECTS I INTERIORS eldxorxwre.arcarla assign. aom 829 A4co01axa 4221 WEST BOY SCOUT BI VD., SURE 150 TAMPA, FL 336D7-5743 813.884.20DO 280 WEST CENTRAL AVE. WINTER HAVEN. FL 33880.2957 963.577.2054 5�W A SF C E NSF •�1! �P��,,,•''�,� *'N o. 71454 t 5/14/20211W O \ STATE OF f? F`s•••.. FC OR10Pr' G� S10NAL e a 7 W c!a � J 0 H � W 0 � IL U �O CL N O V Lu G m J m 0. a m WWKfE PERMIT 1e wmwm 21020 DAIS 5.5.21 DuweK mwm mg. i /C r.04