HomeMy WebLinkAbout36690 Garden Wall Way-- I !I - I 1 1 1 1 - III _ _ I i ,I, Ir II 1' 1 111 11 11 _11 11 Cm CU I x rn LO u7 v cry 0 m 0 J 0 I 3 =I a rn L0 0 0 0 00 0 CJ� N tC v a' 0 C 3 Q N N d E CD E 2 0 c J N a� U N / 0 v 0 J N N N N S 0 0 U Z w r m v N ABBREVIATIONS AB or A.B. Anchor Bolt FIX or FXD Fixed RA or R/A or R.A. Return Air ABV or Abv. Above FLR or Flr. Floor RAD or Rad. Radius AC or A/C Air -Conditioner FLR SYS or Fir Sys Floor System RAG or Rag. Return Air Grill ADJ or ADJ. Adjustable FOM or F.O.M. Face Of Masonry REC or Rec. Recessed AFF or A.F.F. Above Finished Floor FP or F.P. Fireplace RECEPT Receptacle AHU or A.H.U. Air Handler Unit FIR DR French Door REF or Ref. Refrigerator ALTorALT. Alternate FRT Front REINF Reinforcing BC Base Cabinet FT or Ft. Foot/ Feet REQD or Req'd. Required BF Bifold Door FTG or Ftg. Footing RM or Rm. Room BK SH or Bk Sh BookShelf FXD GL Fixed Glass RND or Rnd. Round BLK or BLK. Block GALV or Galy. Galvanized RO or R.O. Rough Opening BLW or BLW. Below GC or G.C. General Contractor RS, R/S, R/SH or R&S Rod and Shelf BM or Bm. Beam GFI or G.F.I. Ground Fault Interrupter SC Solid Core BOT or Bot. Bottom GT or G.T. Girder Truss SO or SO. Smoke Detector BP or B.P. Bypass (door) GYP BD or Gyp. Bd. Gypsum Board SGD Sliding Glass Door BRG or BRG. Bearing HB Hose Bibb SH or Sh. Shelves C Carpet HC Hollow Core SHT Sheet CAB Cabinet HDR or Hdr. Header SHWR or Shwr. Shower CIR or Cir. Circle HGT or Hgt. Height SL or S.L. Side Lights CJ or C/J Control Joint HH or H.H. Hand Held (plumbing faucet) SPECS or SPECS. Specifications CLG or Clg. Ceiling HORIZ Horizontal SPF or S.P.F. Spruce Pine Fir CMU Concrete Masonry Unit HS Hard Surface (flooring) SQ FT or SF or S.F. Square Foot (feet) COFF or Coff. Coffered or Tray Ceiling ILO In Lieu Of SQ or Sq. Square COL or Col. Column INSUL or Insul. Insulation STO Storage COMM or Comm. Community INT or Int. Interior SW or S.W. Shear Wall COMP or Comp. Compressor KIWALL or K/Wall Kneewall SYP or S.Y.P. Southern Yellow Pine CONN or CONN. Connection KS or K.S. Knee Space TB Towel Bar CONT or Cont. Continuous LAUN or Laun. Laundry TEMP or Temp. Tempered CSMT Casement LAV or Lay. Lavatory THIKN or Thik'n. Thicken CT or C.T. Ceramic Tile LF or L.F. Linear Ft. TOB or T.O.B. Top of Block D or D. Dryer LL Lintel Length TOM or T.O.M. Top of Masonry DB Door Bell LT Laundry Tub TOP or T.O.P. Top of Plate DBL or Dbl. Double MAS or Mas. Masonry TP Toilet Paper Holder DCF Decorative Cementitious Finish MAX or Max Maximum TR Towel Ring DEC or Dec. Decorative MC Medicine Cabinet TRANS WOW or Trans. Transom Window DED or Ded. Dedicated (outlet) MFR or Mfr. Manufacturer TYP or Typ. Typical DIA or Dia. Diameter MGT Management (room) UC or u.c. Under Counter DISP or Disp. Disposal MIN or Min Minimum UCL Under Cabinet Lighting DIST or Dist. Distance MIR or Mir. Mirror LINO or U.N.O. Unless Noted Otherwise DMF Decorative Masonry Finish ML or M.L. Microlam V or v. Valve (shower or tub/shower) DS or D.S. Drawer Stack MONO or Mono Monolithic VB Vanity Base DTL Detail MW or MICRO or Micro. Microwave VERT or Vert. Vertical DV or D.V. Dryer Vent NTS or N.T.S. Not to Scale VL or V.L. Versalam OVP or D.V.P. Diverter Valve (plumbing) OE or O.E. Owner's Entry VTR or VTE Vent through Roof / Exterior DW or D.W. Dishwasher OPNG or Opn'g. Opening W or w Washer EA or Ea. Each OPT or Opt. Optional W/ or w/ With ELEC or Elec. Electrical PC Pull Chain WA or W.A. Wedge Anchor ELEV or Elev. Elevation PED or Ped. Pedestal WC or W/C or W.C. Water Closet (toilet) EQ Equal PH Phone WD or Wd Wood EW or E.W. Each Way PKT or Pkt. Pocket (Door) WDW HDR or WOW. HDR. Window Header EXP or Exp. Expansion PL or P.L. Parallam WH or W.H. Water Heater EXT or Ext. Exterior PLF Pounds per linear foot WIC or W.I.C. Walk-in Closet FBC Florida Building Code PLNT SHLF or Plt. Sh. Plant Shelf WM or W.M. Wall Mounted (plumbing fixture) FDN or Fdn. Foundation PLT HT or Plt. Ht. Plate Height WP Water Proof(ing) FFB Finsh Floor Break PSF Pounds per square foot WS Water Softener FG Fiberglass (Shower Pan) PT or P.T. Pressure Treated WWF Welded Wire Fabric (Mesh) FIN Finished PW or P.W. Pre -wire FIN FLR or FF or Fin. Flr. Finished Floor PWDR or Pwd. Powder Room REV. 06.23.22 PLAN REVISIONS DATE VERSION DESCRIPTION 08-20-15 1.0 NEW BASE PLAN 12-8-15 2.0 ADDED VAULT. CLG. 12-28-17 3.0 2017 FBC UPDATES 02-21-18 4.0 ADDED GRADE BEAM 150 MPH ENG. 08-27-19 4.1 ENG. REVIEW FOR 150—C MPH 09-20-19 4.2 ADD 8'-8" ELEV. FOR TREVESTA 12-12-19 4.3 ELEV. B EXTEND ENTRY SLAB 12-15-20 4.4 OVERHANG OVER SGD REV. TO 3- PER C.M. 12-19-20 5.0 FBC 2020 CODE UPDATE 06-14-21 5.1 HVAC DOOR TO 2652 PER C.M. 11-29-21 6.0 ADDED ELEV KLM PER C.M. 1941 Al B1 KLM INDEX OF DRAWINGS SHEET DESCRIPTION SHEET No. CS COVER SHEET 1 FLOOR PLAN 2 INTERIOR ELEVATIONS 3.1 EXTERIOR ELEVATIONS 3.2 EXTERIOR ELEVATIONS F1 FOAM DETAILS 4 ELECTRICAL PLAN 5 ROOF PLAN 6 FOUNDATION PLAN MONO 7 ROOF FRAMING PLAN 8 LINTEL PLAN AND DETAILS SIN STRUCTURAL NOTES SN1 DETAILS S3 DETAILS S4 DETAILS S5 DETAILS SS RETROFIT DETAILS D1 SECTIONS & DETAILS WP WATERPROOFING DETAILS PA1.0 PRODUCT APPROVAL NUMBERS PA1.1 PRODUCT APPROVAL NUMBERS PA1.2 PRODUCT APPROVAL NUMBERS SH1.0 HURRICANE SHUTTER PRODUCT APPROVAL SH1.1 HURRICANE SHUTTER PRODUCT APPROVAL SH1.2 HURRICANE SHUTTER PRODUCT APPROVAL SH1.3 HURRICANE SHUTTER PRODUCT APPROVAL SH1.4 HURRICANE SHUTTER PRODUCT APPROVAL SH1.5 HURRICANE SHUTTER PRODUCT APPROVAL MEAN ROOF 15 FT. HIGH TYPICAL FOR SINGLE STORY HOMES MEAN ROOF 30 FT. HIGH TYPICAL FOR 2 STORY HOMES THIS DRAWING AND DESIGN IS VALID FOR 12 MONTHS AFTER THE DATE IT IS SIGNED AND SEALED OR WHILE CURRENT CODE IS VALID CODE REFERENCES ARE SUMMARIES OF CODE SECTIONS. SEE FBCR (CURRENT VERSION) FOR COMPLETE CODE INFORMATION. Notice to Builder & All Subcontractors It is the intent of Designer/Engineer listed in the titleblock of these documents that these documents be accurate, providing Licensed Professionals clear information. Every attempt has been made to prevent error. The Builder and all subcontractors are required to review all the information contained in these documents, prior to the commencement of any work. The Designer/Engineer are not responsible for any plan errors, omissions,or misinterpretations undetected and not reported to the Designer / Engineer prior to construction. All construction MUST be in accordance to the information found in these documents. Any questions regarding the information found in these plans should be directed to our Office at (407) 880-2333 immediately. No backcharges will be considered for reimbursement by the Designer/Engineer without advanced notification and approval by the Designer/Engineer. Payments will be made in accordance to the terms of the agreement. Control of Construction Site The Designer/Architect and engineer of record (EOR) have no control over the construction site and shall not be responsible in any manner for control of the construction site including, but not limited to, scheduling and sequencing of work, jobsite safety, and ventilation of the building and thereby shall not be responsible for the indoor air quality, or the effects thereof, for any reason whatsoever. The Designer/Architect and FOR has no duty to protect, without limitation, the residence, construction site, materials, or equipment, from moisture, mold, fungus, fire, theft, vandalism, trespass, or any other peril or condition, at any time, expressly including, but not limited to, the period of time before construction, during the construction of the project, or after construction and the Designer/Architect and FOR has no duty to take any action or preventive measures to protect such property against any such peril at any time for any reason. Care and Maintenance Yearly maintenance and inspections by the builder/homeowner are necessary for the future life of this home. Care must be taken to check windows and doors for caulking, remove leaves and debris off roofs, make sure that water flow is away from the house and have your home repainted every 3 - 5 years to protect the coatings. The designer and engineer of record are not responsible for the upkeep of the home and will not be held liable for instances that may occur over the normal life of the home without proper maintenance. RF: v a II Chi N41i �I�f Y c� _K., S W chi Q -0 cc m V y N Y 0 44 cd Ij c .0 a ZLc-E f� U r t . lffo 'iit '0, ` To the best of the Engineers knowledge, information and belief, the structural plans and specifications contained within these drawings comply with the 2020 Florida Building Code - Residential 7th Edition. Engineers signature and seal is only for the structural engineering portions of the drawing pages bearing Engineers signature and seal. H of a O N V N 0 C . " to 'R u' Wcc tl! rNi d ILL LL V 2 O Z N C o LL°g _ o W 7 (6r� 00 m W � 0 4' p w LL Z co 0 N `'QL)toF Z o d DDO W z N 00 (O z 0 N z � � c a N M N z 0 o u- fi a--+ CD CD O w s Ly N N V^) ' C/) A v c LL ~ J E L z� rn I �® o rY+ m tffil 14 o M zc w Z LL- ce E E m =o oz ,m <� as Z M O o x� ¢a a� w0 �o U O �z ¢w a o 0 m¢ Z C� ) D C Q m J U U � Z r �z 3 8< Q0 W Cn 3I T � O wLL E ap aZ � _ J o oz J a< ti3 =C r o M a0 3 =o ,o = LOrn L Q 00 CID� � O r O J 'Ile z— Cr Y T J W m r O N 0) N O) LO E t6 c 3 y o Z Z r a) 16 a c°� Q o JOB NO: 22-04746 SCALE : AS NOTED SHEET NO. C S rn v v Cr 3 x a rn 0 C 0 m O J 4- 0 I 3 Cn In (n 0 a J to I N L0 LO 0 Q 0 0 CA. F�- 0 0 c a N L v cli 0 tom. N N 0 56-10" 8'-6" VERIFY METER A LOCATION WITH T-0" S3 BUILDER H.B. �r ----- L 5-SH T DPr R&S ---- ---- LOCATION NVERIFY ELECTRICAL PANEL TYP @LIN K N ' OWNER'S SUITE -6" O.BAT N W.I.C. I OC* BUILDER TO PROVIDE 2-6 APPLIANCE PROTECTION° I I I I GARAGE OPENING ■ TB CD 8'-0" CLG. 50 8-0 CLG. 8-0 CLG. I WHEN REQUIRED PER FBC I I I CARPET TILE o CARPET I 2 CAR GARAGE I I �w I N 1T-8" -10" 3'-0'r r 7'-8" jL 8'-0" CLG. 20'-0" s 1 1 175„I 8 A L6Ir r>w 5._32" 82 T-10" 2668 I Cr I 00 I I 2868 HANSON II EDGE OF SLAB 2" p I I I BOX @ 36" I EYOND WALL Q o � A.F.F. _ t I 2 io it 60"x36" _ N DRYER VENT I K I wTHRU L %I ROO S3 I >GSHOWER ------- &S(" 00 S3 (3) 2x4 #2 SPF w/ SS .- I ocaao--- DTT2Z @ BASE D r TP I l l l TYP @ 1 STORY 5'-11g' I 4'-0" IrA S3 I I/x U cil NOTE: FINISHED I i /f, j 1� 1. -� V IL ¢ �I I WALLS TO BE I I CO AHU LAU � i I FLUSH. VERIFY IN I I ~71 CLG. I I FIELD. I r C I h`1 TILE ti6 L ----- ----- r2868 K CC D 1 oo I S3 S3 S3 •- r = (n I FAMILY RM R.A.G. q' o O L 2:12 VAULTED CLG. 1 9'-4" CLG. (3) 2x4 #2 PF w/ ibyER DTT2Z @ ASE `�o CARPET 3068 I o ^ I I ENTRY = 23'-8" 3'-10" T-8" 10'-108" in TILE A A 6 I 8'-0" CLG. U') 1 I HDR AT 7-4" I I I r -------R&S------ �. 2668------- iba0 2668 �00 R&S r r - - - - - - - - - - - - 4'-0" 11'-7s' 6'-10" c� -' -' 4'-7" 8'-8" N 5'-4° co 14'-6" 5.-4. N 7�_6" i i I 5068 B.F. 4068 B.F. OPT. I I b I I-----C---=--� ---- REF. r- BEDROOM M(D 2 =o_ Z �, N K ° PATIO CAFE --------- r - � 8 -0 CLG. , ' " BEDROOM 3 u6z T J BEDROOM 4 _W tn� A M� O VAULT. CLG. ��/ J i D.W. I a °O N Z) U I CARPET _ I 8 -0' CLG. BATH I 8'-0" CLG. ~ w - o 00 CARPET t T Q � 'L - Z' - J 1B N> U b`° CARPET I 8'-0" CLG. ;- CARPET Oi � i SINK w/DISP I TILE 2" i 21'-2"CD 2'-2" 2, 10'-4" r 10'-42' 2' 4' I VAULT. CLG.. �:. L1 I Ca TP m I ■ i I TILE - - o6� rL PANTRY a inI I TB TYP @ 1 i� RANGE `� 8'-0" =w r ^ I STORY ;: 36 36 FLAT CLG. ,� I FIBERGLASS I AC PAD ---'rl4 5-SH '- I SURROUND ° � I "' S3 �� .00. 16" DEEP fl 11111IM111111171111111101, H B EGRESS EGRESS A OS3 O 29'-8" 15'-10" 19'-6" 65-0" HEADER SCHEDULE MARK HEADER SIZE REMARKS H 1 (2) - 2X6 #2 SYP W/ 1/2" FLITCH PLATE H2 (2) - 2X8 #2 SYP W/ 1/2" FLITCH PLATE H3 (2) - 2X10 #2 SYP W/ 1/2" FLITCH PLATE H4 (2) - 2X12 #2 SYP W/ 1/2" FLITCH PLATE H5 (2) - 1 3/4" X 11 1/4 LVL 2.0E Fb=2950 H6 (2) -1 3/4" X 9 1/4" LVL 2.0E Fb=2950 H7 (2) -1 3/4" X 16" LVL 2.0E Fb=2950 H8 (2) - 1 3/4" X 71/4" LVL 2.0E Fb=2950 (2) - 2X4 #2 SYP W/ 1/2" Follow Q/S4. See Plan for RAG FLITCH PLATE Bearing Wall Call Out When Straps are Required * VERIFY W/ PLAN CORRECT LENGTH OF HEADER REQUIRED ** SEE PLAN FOR DETAIL CALL OUT FOR CONNECTIONS AND REQUIRED STUDS WINDOW SCHEDULE SIZE R.O. CMU (Flange) R.O. FRAME (Fin) TYPE 12 20 X 26 18 } X 25 i S.H. 13 20X38J 184X371 S.H. 14 20X50J 184X50 S.H. 15 20X63 18#X62J S.H. 16 20X72 184X71 S.H. 11-12 271/4X26 26X25 S.H. 1H3 271/4X38J 26x37 S.H. 11-14 274X50J 26x50 S.H. 1H5 274X63 26X621/2 S.H. 1H6 27}X72 26X711/2 S.H. 22 37 J X 26 36 J X 25 1/2 S.H. 23 374X38J 364X37314 S.H. 24 37 J X 50 J 36 4 X 50 S.H. 25 37 J X 63 36 J X 62 112 S.H. 26 37 J X 72 36 J X 71 1 /2 S.H. DOUBLE 2 WIDE 75" TALL 73 � WIDE S.H. 32 54 X 26 52 } X 25 4 S.H. 33 54 X 38 J 52 J X 37 J S.H. 34 54 X 50 1 52 4 X 50 S.H. 35 54 X 63 52 J X 62 J S.H. 36 54 X 72 52 J X 714 S.H. 39X59 40 X 59 DOUBLE 39X59 79 X 59 N/A S.H. TIE WALLS TOGETHER BY ROTATING BLOCKS EVERY OTHER COURSE General Notes R302.5 Dwelling/Garage Opening/Penetration Protection Opening and penetrations through walls or ceilings separating the dwelling from the garage shall be in accordance with sections R302.5.1 through R302.5.3. R302.5.1 Opening Protection Openings from a private garage directly into a room used for sleeping purposes shall not be permitted. Other openings between the garage and residence shall be equipped with solid wood doors not less than 1-3/8" in thickness, solid or honeycomb -core steel doors not less than 1-3/8" thick, or 20-minute fire -rated doors. R302.5.2 Duct Penetration Ducts in the garage and ducts penetrating the walls or ceilings separating the dwelling from the garage shall be constructed of a minimum No. 26 gage (0.48 mm) sheet steel, 1 inch minimum rigid nonmetallic class 0 or classl duct board, or other approved material and shall not have openings into the garage. R302.5.3 Other Penetrations Penetrations through the separation required in Section R302.6 shall be protected as required by section R302.11, Item 4. R302.6 Dwelling/Garage Fire Separation. The garage shall be separated as required by Table R302.6. Openings in garage walls shall comply with Section R302.5. Attachment of gypsum board shall comply with Tab;e R702.3.5. The wall separation provisions of Table R302.6 shall not apply to garage walls that are perpendicular to the adjacent dwelling unit wall: • From the Residence & Attics - Not Less than 1/2" Gyp. Bd. or equivalent applied to garage side. • From Habitable Rooms Above Garage - Not Less than 5/8" Type-X Gyp. Bd. or equivalent. • Structure(s) Supporting Floor/Ceiling Assemblies - Not Less than 1/2" Gyp. Bd. or equivalent. • Garages Located Less Than 3 Feet From Dwelling On The Same Lot - Not Less than 1/2" Gyp. Bd. or equivalent applied to the interior side of exterior walls that are within this area. R312.2.1 Window Sills In dwelling units, where the top of the sill of an operable window is located less than 24 inches (610 mm) above the finished floor and greater than 72 inches (1829 mm) above the finished grade or other surface below on the exterior of the building, the operable window shall comply with one of the following: 1. Operable windows with openings that will not allow a 4-inch-diameter (102 mm) sphere to pass through the opening where the opening is in its largest opened position. 2. Operable windows that are provided with window fall prevention devices that comply with ASTM F2090. 3. Operable windows that are provided with window opening control devices that comply with Section R312.2.2. Chapter 45 Private Swimming Pools Outdoor swimming pools shall be provided with a barrier complying with R4501.17.1.1 through R4501.17.1.14. M1507.2 Re -circulation of Air Exhaust air form Bathrooms and toilet rooms shall not be re -circulated within a residence or to another dwelling unit and shall be exhausted directly to the outdoors. Exhaust air from bathrooms and toilet rooms shall not discharge into an attic ,crawl space or other areas inside the building. GAS APPLIANCES G.C. to verify location of gas riser before commencement of work. Where gas water heaters are installed. Water heaters shall be installed a min. of 18" above flr. per FBCR G2408.2. Except where appliances that are listed as flammable vapor ignition resistant. OPENING PRESSURES ENCLOSED - EXPOSURE "C" �A +29.7 / -32.2 © +29.7 / -39.7 © +28.3 / -30.8 OD +28.3 / -37.0 O� +26.6 / -29.1 O +26.6 / -33.5 O SEE SN SHEET SEE SN SHEET 140 MPH NOTE: WIND SPEED INDICATED ABOVE IS AN "ULTIMATE" WIND SPEED. THE WIND PRESSURES LISTED ABOVE ARE ALLOWABLE PRESSURES SOFFIT DESIGN PRESSURE 1 +29.7 / -39.7 WALL LEGEND TYP. 2x FRAME WALL BEARING WALL INTERIOR BEARING WALLS NOTED "FLOOR BEARING ONLY" ARE FLOOR SYSTEM SUPPORTING ONLY AND REQUIRES NO UPLIFT CONNECTORS TO FLOOR SYSTEM AREA TABULATION "A1" 1 ST FLOOR LIVING AREA 1936 LIVING TOTAL 1936 GARAGE 416 ENTRY 20 TOTAL AREA 2372 PATIO 23 INSULATION REQ. LOCATION I R-VALUE / TYPE EXT CONIC WALL R-4.1 HIGH PERM EXT FRAME 2 x 4 R-11/R-13 KRAFT FACED FLOOR PLAN EXT FRAME 2 x 6 R-1KRAFT FACED ELEV-Al CONDITIONED CEILING R-30 BLOWN -IN (INSTALL BAFFELS AT EAVE) I GARAGE SEPARATION IR-11/R-13 KRAFT FACED SCALE: )/4 r=V-0" (GARAGE / LIVING) _44- _ Q c N 0 cr) 5�W C= . CL o 92. 04 _" Q U •® It rcd LL a- N p v N ca a) (1) E v� U V 3t U >lz.� > Airo E o :3 0- 1' o'^4� To the best of the Engineer's knowledge, information and belief, the structural plans and specifications contained within these drawings comply with the 2020 Florida Building Code - Residential 7th Edition. Engineers signature and seal is only for the structural engineering portions of the drawing pages bearing Engineers signature and seal. N W Q O N U N SO ~ i! � J fA cn LL w N 0 Q CoJLL LL 13 di �Mv w a a 0- Y (D Z 00 t:°o �. N C_O 0 M Q L 3 M W rn I _1 r- z Z co Z IL _w 00 N I­_O L) ❑❑❑ 13 Z W OZ N m o g z (D��� Q - - E3 N M U) N z � � o CCSV w W � m U 0 w o U cli w � _ ;_ 8 I = L • U O N N M o CID w z M Q O zo �O � z Qo Q Z a C O _ U as O U � Z co � < i z w z n3 oU m m m 'aw }}1 ~O g LLLL zO Q U a 8- I w NF W m a & w F �0 o M w� �o okoar 3 c Q = No G > (I� t ^ L I LO cc Fes- 00 Co 0 r- J :3 T O �" . T /^ V/ m � QI O N o o N n LO E c00 o Z `° ZE r B C a U _ ¢ 8 JOB NO: 22-04746 SCALE : AS NOTED SHEET NO. 1 - I - - - - I - - - - ll 11'1 II I I - - -- C-> S 3 rn LO rep C Cr cn .G co O J co O I 3 I x LO LO L O co O J I CV L Cr Cn 3" O C H Q N 0 a E H N E 0 0 1= J N CD 0 0 0 J N N t� 0 a N N 0 0 0 0 w m til VARIES, 2" LESS THAN CABINETS BELOW MIRROR VARIES / w MEDICINE CABINET o0 � 0 � O H CO CV � M tC) M M KITCHEN ISLAND KITCHEN O 60 NOTE: THIS DIAGRAM DEPICTS TYPICAL INSTALLATION GUIDELINES TO BE FOLLOWED U.N.O. ON PLANS 24" TOWEL BAR ON WALL ABOVE TOILET TOWEL BAR ON BATHROOM WALL I - TOILET PAPER i HOLDER CD CV FIN. FLR. SHWR. SHWR. CURTAIN HEAD ROD a TOWEL BAR IN TUB OR SHWR. SHWR. VALVES C° SOAP - DISH 0 I O 0 TUB BATHROOMS, SHOWERS AND TUBS DOUBLE RODS M SINGLE ROD CLOSETS / LAUNDRY M V O N � 0 OPT.' REF. O KITCHEN O n BATH 2 O 50 C 4 MIRROR i 4 OWNER'S BATH INTERIOR ELEVATIONS_ CABINETS — 36" H UPPER CABINETS — 16" FOR LINEN 30" H UPPER 12" FOR PANTRY CABINETS — OVERHANGS THAT EXCEED 12" MAY REQUIRE A SUPPORT BRACKET 36" H BASE o O o FINISHED CABINETS COUNTER TOP 30" H BASE C° CABINETS 0 00 LL = .-IN C)00 ' � n I CO in 0 2x r > '_n FRAMING To 0 0 ♦♦_000 1 /2" GYP `o `r N ' (V co 04 BOARD I FIN. FLR. t- FIN. FLR. 2x P.T. SOLE PLATE SHELVING ISLAND COUNTER CABINET BLOCKING BLOCKING AND MOUNTING DETAILS SCALE: 1 /2"=1'-0" r _ c 0 0�p S �w °' o �q ap, C 00 C" 0 5 cCU d-0mx ® sum u. n. +� �� N� -�'® g NN C -EZc C 0 tv 2 c E m ?a o o i mot+ -, o" liilil r � k � r C6 C7 To the best of the Engineers knowledge, information and belief, the structural plans and specifications contained within these drawings comply with the 2020 Florida Building Code - Residential 7th Edition. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. EE a O CM $ N N : V N O C 0 -- # 0 'q r I; V u w U- d Y J Ij z z 0 z t V c « O 0 p 00 Ri 'N (O W Og co °' °1 J Q ¢ m ILu' W Z N M Z w O U Z U) ❑0❑ W � V) Cl) c� O 0 L'o(o N z � � Q � N M N z D 0 O C1 W o a U � o O W)V) Ln ti m N U) wa U) W " J E 55 nl zll ® p N w M C")Q J Jz � Z � LL- C60 z o o� }m o E :J w z 0z® a 0 x0 ¢ ¢ 0O U O ¢ CEO ra M Q Z <O w Z ¢ c o . mo oz m v J o� .2 m z Qw am gQ zz Z a0 c o A 0 N W �i 3 Jw o w� a 'o zl< 0 O tic-, LO m TO _ Fes- 00 CO O T G : C) J r Y U) m m QI O N o O N CLO T Q c10 r E 00 o z z E T— N c a U a ¢ o c JOB NO: 22-04746 SCALE : AS NOTED SHEET NO. 2 I II ' -L-- ---i --- I I I I I I 111 1111111111 11 I 1 1 11 -- — I - 1 II M N. HEEL 12 5� 12 :Jb bN F.FL. — ------------------------------- 17111:1.11:171::1 El FE71 FE71171 u'LL�j E E] El FE711711 F171 E:1 1.• 16070 OVERHEAD D••' FRONT ELEVATION - Al 5 - - SHINGLE OR TILE ROOF PER COMMUNITY SPECS - INSTALLED PER 4'-0" RIDGE VENT MANUFACTURERS SPECIFICATIONS 5:12 IMINamI iffMINEWI - 25 SH 25 SH — — _ F.FL. ----------- I --------------------------------------------------------------------------------------------------------------------------------- [ LEFT ELEVATION - Al REV. 09.24.21 C p Q O N d �C" MOM i7 5 W t9 • � a� o b N r a �OY W ® .:EYc Q (D U G a) Cr Aiik �a° 5 0 To the best of the Engineers knowledge, information and belief, the structural plans and specifications contained within these drawings comply with the 2020 Florida Building Code - Residential 7th Edition. Engineers signature and seal is only for the structural engineering portions of the drawing pages bearing Engineers signature and seal. N1 W `toEo 2� a p N J N n 0 � LL vi Vi N C) u. d W Vi N M V� W d LL d Y LL z V Z N C O= @ p O L W oga,00 o, Q 0 W Z Wr)N ILM Z N rV z O V ❑[]❑ Z W M `DM Z N (O O Z m QNQ arms 63 Z O Q Q � J — � N E3 N c� N Z U o X(� w -s m t A V 0 w g V) c N y in � • (6 � U w E t U o H C Q` co w C�7 M J y ¢ O Z E LL i a > N ¢n D_ � E wz z F 6 p E ga ¢ �o a 0 Q z [O ru ¢i Z w Z ? C < zz z i Y m f 10 Z m� N�2. <� o� Z ao W cn oLL w a NF o z 3 o w w a .0 .0 0 A n" o3 O N > (fl I..V L0 LOcc — 00 W O i 0 T Q� O NLO o O N � m E c � o Z m Z 0 N E T c 4. U J Q 0 0) JOB NO: 22-04746 SCALE : AS NOTED SHEET NO. 3.1 rn i v U S I cy— rn r� v v- N C) 00 O J 0 I S 3 x Q WO LO v 0- N O Q 0 0 O I N In In L v v En 0 Q rn e Q 0 / v a r° N O 0 J C a� Z3 0 / 0 v 0 d LZ N O :3 a 0 a N O co 0 0 0 0 U Z W 0 O 0o 4' OFFRIDGE VENT 12 12 �5 SHINGLE OR TILE ROOF PER 5� COMMUNITY SPECS - INSTALLED PER - MANUFACTURERS SPECIFICATIONS T.O.M. 3'-10" - HDR HGT. 1'-On — --------�------------- — ------- --------- _ — � EXTENDED 3rxs OVERHANG TO BE CENTERED _ ON DOOR t r j TEXTURED co co 4 CEMENTICIOUS rr d. FINISH ON C.M.U. j31 SH 35 ---------------------------------------(--- ------ 5068 SGD REAR ELEVATION — Al SCALE: 1 /4"=1'-0" 14'-0" RIDGE VENT 12 1 V-0" RIDGE VENT 5� 12 SHINGLE OR TILE ROOF PER 5:12 �5 COMMUNITY SPECS - INSTALLED PER MANUFACTURERS SPECIFICATIONS 4'-0" RIDGE VENT 5:12 T.O.M. HDR HGT. --— — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — 1'-0" 1'-0' TEXTURED CEMENTICIOUS TEXTURED FINISH ON C.M.U. CEMENTICIOUS P 3'-0" 01 (TYP.) FINISH ON C.M.U. 00 (TYP. ) CO F.FL. — RIGHT ELEVATION — Al SCALE „4 — REV. 09.24.21 C O v w c� N C) th ai n X -7 cn ors 4-4 N V ✓ L ,z a L) CL C S:- � N �� O a V r �; '•. , fel S S i O To the best of the Engineers knowledge, information and belief, the structural plans and specifications contained within these drawings comply with the 2020 Florida Building Code - Residential 7th Edition. Engineers signature and seal is only for the structural engineering portions of the drawing pages bearing Engineers signature and seal. bl W a E S w �8 "m 0 0 C: *k � w LL w Q JJLL tl Y z LL Zccrn O O r m v O a o O W tnI� a Z °' rn Z ILz M Z U O F N O U ❑UU Z W N f7 O z N z � � � J V) z w � O V1 N w C' r .. �.. — U c W J E N L U p m 00 Y Q O M J �3 > x U- Co vl w� > oa F- ��a "8 o� co ro� aapp wZ F w� S �w COrn cl zp m J G tl E N Z Z T 5 O 00 4 0 az N F �z � J <Q 3 _0 o c� V' .o a U zla N O > (0 ' ^ L / 0 rn M H L.- 00 Co O T � O ,-- C T W m T QI O N N r, Lid O� T Q Cfl r m E 2�1 o z m Z E � E cn �' c a U Q p JOB NO : 22-04746 SCALE : AS NOTED SHEET NO. 3.2 2" "NOTE: VARIES ill, CAP CAP N N FOAM TO BE USED 1"RADIUS 2" 1 00 CO ONLY WHEN REQUIRED BY COMMUNITY SPECS. IF NOT, DETAIL TO BE 1" 2" OPENING VARIES =N ^ N 3 1/2" RADIUS 3/4" RADIUS ° 1/2" RADIUS V-�rr -�� 1 1rr BUILT W/ STUCCO. 1/2" RADIUS 1" 4" VARIES " 1" 1" N EDGE OF 1• OPENING VARIES V-4" N o 22 r VARIES N 2 VARIES rN 1rr 1r_Or, 1r 1 1/2" RADIUS 4 34r Orr 4rr 42 Nv �o 2 1!2" RADIUS VARIES 12" 3zr 11" zrr - 3- 1" N �r 3�r zr 1° 1" BASE BASE N r 1" 1rr 3rr 3rr a a 1 r 8rr err 4 N 1�r "NOTE: VARIES 8" 2" 3rr FOAM TO BE USED ONLY WHEN co � REQUIRED BY COMMUNITY SPECS. IF NOT, 1" OPENING VARIES 2" �N 1'-6" 1" V-4" 1" r� DETAIL TO BE 2" 2 BUILT W/ STUCCO. EDGE OF OPENING L pff�.�--6--� 24 • ' O 1-1/2" THICK 1-1/2" THICK 4" 101, N 1 M ,rr 10" 6" 'Irrl N qT Cl) ,r, N LJ 2r1 Orr 3" 2rr 2rr N M I 32 1-1 /2" THICK ,41 -41 2`r'-4i4rr " - - M r, �27"52" - f- 3" CD 00 INT I I� J M , VAR[ V- ARIES v U) — VARIES VARIES 4" 8" 1 " air 2 - - Ft1� �� - 00 C14.�1' 00 `° A !L, ^ ^ 1r Lr 4a 6" 4" CV CV co KEYSTONE F11 0 OPTIONAL KEYSTONE F11 OPTIONAL L3" 2rr M 2 Rg4r„ 2 ' 4" GARAGE DR. OPENING 4" 3 a 4" WINDOW OPENING 4" y" NOTE: • INSTALL OVER STONE, TYP. VARIES • FIN. TO HAVE TRADITIONAL LOOK & SMOOTH FINISH • FOAM/ EPS MATERIAL IS ACCEPTED NOTE: • FIN. TO HAVE TRADITIONAL LOOK & SMOOTH FINISH 14 r 1 r_64rr 14 . 11 " 2'-1" 1'-4rr • FOAM/EPS MATERIAL IS ACCEPTED 54 1' 12' T-8" 7" N 1 " 4" 3r_0" 4"- -- iv 101, 1 r�rr 101, f2" CO 00 r co N '� -- - - --- SY o0 0 � --- N� �N M � O 1 -V 1" GENERAL NOTES: - • 1.5 LBS DENSITY STYROFOAM NIS • POLYCOAT (HARD COAT) EM / • ACRYLIC SAND FINISH I t Q N O N ® N N c» 14g W © am a�coX 4 tt N �I CN aL 0 E4� N O � ul s� > 1 -44 0 CL C� O N N 0 To the best of the Engineers knowledge, information and belief, the structural plans and specifications contained within these drawings comply with the 2020 Flor da Building Code - Residential 7th Edition. Engineers signature and seal is only for the structural engineering portions of the drawing pages bearing Engineers signature and seal. in W v EEO S N N �! rp 7k CA V C J V 0 Z Q > n co m u- M cnMo ° w a a Q oU_LL a Y Z O 0 Z L N D t wo ar � = CqN_� m O Q W oga, a cow Z oo 6 M Z O F IL N U z O U ❑❑❑ Z W M z Nto O O Z Z � LZ. � - 3 V) L/ O O w s �Ln N N U � c _ E m =jl _!y LJJ i. U O � ® 0 N 0 z z M M J � Z p i Z � tL _ = zo o >ry a ry Z O E Co V s coo z® ❑ a o e2 Q CO t -z a z coo aw w 03 VJ C 3a omZ o0 Z�c m U J mo 'az w a ° o z go cn m W LL <o z d� -G a z�< 8 N 0 >� '^ L / LO rn m < cc 0 00 co O T C :3 O J Y r Cr T M ¢� O N o o N t` � Ln Q E c00 o z N z N E T c d E U J Q J JOB NO: 22-04746 SCALE : AS NOTED SHEET NO. F 1 to 3 v c.i s 3 I x rn L0 ID v 0- 0 C7 J 0 I U tz to to L 00 C7 co I N t[ O 7 N 0 3 CI a N v a d O `o c y U C> i 0 0 J m L�. N N S 0 0 a N N S 0 0 U Z ELECTRICAL SPECIFICATION NOTES: ELECTRICAL CONTRACTOR MUST VERIFY WITH THE SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT FIXTURES SHOWN ARE FOR LOCATION PURPOSES. GENERAL ELECTRICAL NOTES: Notes: unless otherwise noted, 1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). In a Flood Zone, all electrical equipment to be at or above DFE. Kitchen 44" AFF Bathroom 39" AFF Laundry Room 36" AFF Exterior Waterproof 12" AFF Garage - general purpose 44" AFF Range 2" AFF 2. All trim plates and devices to be ganged, where possible. 3. Electrical switches to be at 42" centerline above finished floor. 4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & sizing of all electrical, wiring & accessories. 5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. 6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. 7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC 2017). 8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or LIL 2075, gas and vapor detector sensor, according to the installation. 9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a Nationally Recognized Testing Laboratory. 10. Keep all smoke detectors minimum of 36" from bathroom doors. 11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be equipped with a monitored battery backup. 12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not acceptable. 13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying with R4501.17.1.1 through R4501.17.1.14. 14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in corner counters. ELECTRICAL KEY DUPLEX CONVENIENCE OUTLET PEF DUPLEX OUTLET ABOVE COUNTER W.P. WEATHERPROOF DUPLEX OUTLET G.F.I. GROUND FAULT INTERRUPTER DUPLEX OUTLET HALF -SWITCHED DUPLEX OUTLET f� SPECIAL PURPOSE OUTLET DUPLEX OUTLET IN FLOOR 220 VOLT OUTLET $ WALL SWITCH $3 THREE-WAY SWITCH 24 FOUR-WAY SWITCH jR RHEOSTAT SWITCH CEILING MOUNTED LIGHT FIXTURE ® HI -HAT - TO BE SURFACE MOUNTED ON J-BOX WALL MOUNTED LIGHT FIXTURE ORECESSED LIGHT FIXTURE P.C. LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS TRACK LIGHT FLUORESCENT LIGHT FIXTURE Q EXHAUST FAN Q, EXHAUST FAN/LIGHT COMBINATION ® D ELECTRIC DOOR OPERATOR (OPTIONAL) CH CHIMES (OPTIONAL) PB PUSH BUTTON SWITCH (OPTIONAL) PUSH BUTTON SWITCH - DOOR BELL SD SMOKE DETECTOR CM SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) TELEPHONE (OPTIONAL) USB TELEPHONE/USB (OPTIONAL) ® TELEVISION (OPTIONAL) ® 2 (2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. O THERMOSTAT �]M ELECTRIC METER owl ELECTRIC PANEL J DISCONNECT SWITCH &�3 ROUGH -IN FOR OPT. CEILING FAN q��Z CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR G T J OPT. CEILING FAN A9 (1) PHONE LINE, (1) DATA PORT 150AI200A INDOOR PANEL CENTER NEMA1 150 AMP/ 200 AMP A14 to lights 8 outlets 912 to appliances and GFI k10 to WH k8 to Range 66 to HVAC MAIN t Or2oo=4'10 50=20 in 2" Conduit 200 amp 150 amp UNDERGROUND Disconnect SERVICE BY POWER CO. INTERSYSTEM 4 Bare Cu Ground BONDING #4 GROUNDING WIRE TERMINATION PER WITH CODE APPROVED NEC 17, 250.94 CLAMP PER 250.50 AND 250.52 OF THE 2017 NEC. Typical 150-200 Amp Electrical Riser Diagram REV. 03.09.22 NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE PROVISIONS OF THE NFPA 70-2017, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL CODES AND THE LOCAL POWER/UTILITY COMPANY. l" G CAFE 1 vll 2't Ad ETA PLUMBING RISER_ NOTE: PLUMBING RISER IS SCHEMATIC TO SCALE: NTS BE VERIFIED WITH PLUMBER OWNER'S SW� ITE T / ROUGH -IN FOR / OPT. CLG. FAN/ LIGHT PRE -WIRE / I O. BATH FAMILY RM 1 / I G � ROUGH -IN FOR OPT. CLG. FAN/ LIGHT PRE -WIRE I U.C. OUTLET FOR DW Cn U.C. OUTLET I RECEPT. FOR ALARM SYSTEM 15' VERIF METER LOCATION WITH BUILDER WP H.B. r ---- I A GFI ' IRRIGATION ----�1 _ VERIFY LOCATION GFI @ 44" A.F.F. W.H. ELECTRICAL PANEL I 0 I I W.I.C. I I I \ 2 CAR GARAGE I I I I GFI FOR GAR. DOO� GFI I GFI @ 44" A.F.F. -----------J _ I OPT. D. GFI L U AHU I GFI @ 44" A.F.F. I I I \ OPT. 4 GFI REF, GFI L---------- GFI D.W. I SINK w/ DISP — K I TC H E N U.C. SWITCH FOR DISPOSAL PENDANT AS \ PER SPECS \ _ — � RANGE in \ M i . 3 GFI : GFI i DEDICATED RECEPTACLE H.B. FOR MICROWAVE RANGE HOOD PER SPECS I GFI f= I I BEDROOM 2 ROUGH -IN FOR C �/ OPT. CLG. FAN/ LIGHT PRE -WIRED / FOYER,' NTRY I WP j ELECTRICAL PLAN - ELEV-Al SCALE: %4"=1'-0" C" C9 U Uj . CL O 3RU�� Q -0 CO X � L ® N U �� r Q u .c U (3) 0) LY c F ro o a v N 0 N N co 0 To the best of the Engineers knowledge, Information and belief, the structural plans and specifications contained within these drawings comply with the 2020 Florida Building Code - Residential 7th Edition. Engineers signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. W a C . N O N ci Co N_ V N � i! Lu �2s N Q rNi v LL a ro -J LL 2 0. Y 0 U- 55 z J Z =@�_ 0o �ro = o W 7 f6 (N m J Q o IL to NZ UO = M 0 = N Q U Go H OU ❑❑❑ W V M _ o Z N z � � Q CN N z 0 � o u- (� C 7 w Z 'ram • V 0 w o v) C N Y I =DWalk v c w m L 8 I v o c rn Q 0 s Q N M M J w q 0 S2 Z Z 4 E W E z �= 20 Q� w oa �� o aaZ �o Z t ao wo �Z �w n' c C o� Z J 2Z ` ° Z Z o 3 Q � W in o Q w� 8 az H w 3 -0 M 0 a v old � 3 y O Lnrn L) Q c� F— 00 O T O r VJ m m QI O N o O N n LC) T Q CO T E o z :300 r to ccC6 a E U ¢ p JOB NO: 22-04746 SCALE : AS NOTED SHEET NO. 4 ROOF PLAN - ELEV-Al SCALE: %4"=1'-0" c� Q _ C 0 Cn W 5 CM 0m X Q !_M 5U-t2 > � � Mc Qom. Q Q� co 0 -, C L f= c U Q d C� rri U �a y I To the best of the Engineers knowledge, information and belief, the structural plans and specifications contained within these drawings comply with the 2020 Ronda Building Code - Residential 7th Edition. Engineers signature and seal is only for the structural engineering portions of the drawing pages bearing Engineers signature and seal. fA W a o o O M U o N co p fJ N O C) ik «7 _ Co N (7 � N LJL J W vi VJ � '- to CN v Q W W w a d JUu- a c� z 5. Z r mo o 0 o rt J WCo 0 r- rn rn ¢ z Z c� LL0 O F N V' O U Z ❑0❑ W J N O _ QNQ Q C � •� R r M ^N G (? C W O _ 41 T V) LJ y Un U) V) U d c u� J m ;I s () o y C D N � CAD CO Z M J LL- (V fl- V z o �� z z < c ZirtJ E UIcu F— M1 L z E0 as =0 c0 o< a z O� a z <tt In rC f;i < o N C m o 10 ib Q z I 5 C o C a a LU C) O w a w F m ¢ oLL tt 3 aQ rrCD, o 7 0- > FM d _ 3 2 O N i� W '^ L / O — W co O r— : O J Y T � r ) W m ¢� o c) C LO r Q CD r" E 00 Z m Z � E w E T � E c d U J Q 16- J JOB NO: 22-04746 SCALE : AS NOTED SHEET NO. 5 3 U 3 I rn L0 m d CY Cn 0 O 0 J O I 3 I _ a rn Ln v7 v cnn 0 m 0 J 0 I L0 02 v N O C 3 QN O i a 0 N E O _ v y C U N 0 c 0 :.r v r cli O 45 0 0 a- N N S 0 0 U z W m 0 ,_r" 5'- TYP @ 1 STORY U.N.O. A S3 ff 6-0" VERIFY METER LOCK -ION WITH BUILDER ..W� 5'-28" 15-0" ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ r T: 1 1 VERIFY LOCATION / ; I ELECTRICAL PANEL (VERTICALS w/ in BUILDER TO PROVIDE FILLED CELL 0._01 1 :: I : ; 2.6 APPLIANCE PROTECTION ■ I ; I : ; WHEN REQUIRED PER • FBC 35-4" 20'-6" N �'°° M2 LO I C) I: S3 f J S3 CV 2._74., 4, 9" 4'-10" • EDGE OF SLAB 2" o ■ • I CJ GJ' I BEYONDALL v - - - - - - - -1 I • c? 5'_3" 1'-10" 3'-6" I� '�cv M 0 N I 41 I (2) #5 REBAR I I VERTICALS w/ in I I OPT. WI I I OPT. D -3 1/2" ih FILLED CELL 2'-6"x2'-6"X1'-0" FTG G W/ (3) #5 E.W. S3 r 1 L - - J —._ �T I L-- J L - - - - 11 --- • : J L - 3'-5" SLOPE 7 '_1" 717 (2) #5 REBAR r �I F_ 2'-6" x 2'-6" x V-0" TYP @ 1 STORY I iv AHU 1 VERTICALS w/ in I W/ (3) #5'S E.W. U.N.O. ici I S3 CC S3 FILLED CELL I o0 S3 i CJ ao I 25'-1047,, ii/ ..... 95$ ........ —------- ■ ■ 4'-4" v 2'-6"x2'-6"X1'-0" FTG W/ (3) #5 E.W. -4„ I L o INDICATES FILLED CELL w/ 3000 PSI 3-1/2" MIN 3000 PSI CONC./ SLAB FOR HERNANDO X 1 PROVIDE %2' x 9 Yz" "' SLOPE (2) #5 REBAR CONC. GROUT FROM FT. TO BEAM COUNTY ONLY i i RECESS FOR FRT. POOR VERTICALS w/ in W/ (1) #5 REBAR VERT ABOVE SLAB 3-1/2" MIN 2500 PSkWNC TOP PAVER 0 BE 4'-0" I 4'-4" 4'-6" FILLED CELL I TYP ALL PLACES SHOWN @ SLAB OVER 6 t ,\ iSQUEEN Ma � 0'-0" 4"BELOW FIN. FLR. L FIN. . ■ : ■ ■ ■ ■ HOOKED FTG. DOWELS 5" EMBED I VAPOR BAR/Ri�t , • ...... ..... .....: W/ 25" EXT. ABOVE SLAB "GRADE 40 � � :::::::::: ; .......... • L ........................ • • • • • • STEEL" — — — — — _— — — — — 0 4'-0" 16'-10" 12. 10.. 0 10'-10'" a STEPS AS REQUIRED PER FIELD n-- --i I - i i KITCHEN ISLAND III • • • i i LOW WALLS III OPT. I.. v CONDITIONS C F _ _ _ _ _ _ _ _ _ _ - - � CJ REF. :: � CJ CJ:: CJ � jr PROVIDE 1 �" RECESS �_- -_- -_ �r-�I CHASE TO ISL�ND �TYP � @ 1 Ir %IFORSGD.REFERTO ; t I STORY U.N.O. ooWIDTH MASON'S SLOPE FOR I r.) II r I D.W. III II I J�-- �" ' I} ti" 'n v L� - �L_Jl= :: :: III °D S3 `O `O S3 i SINK / DISP 3 1 /2" I " r I I t L- — — i i 16'-0" 2'_9 a 6'-10" .. II C / III U-0" r ■ ■. �� :: :: III Av- "' o �' AC PAD HVAC CHASE BASED ON i/ LOCATION i•i ���%�� � :: .. :• �� 1 io t 1� _ o � — — — -�, — — — — +— h1m, .. .� . .. J .:.. . . . .� . . . .. .. .: .. .. .. . .. . .. . .. .. .. . . . . . .. .. . . .. . . .. . .. . . . . : .. ■ _ - ■ i �. ■ TYP @ 1 STORY H.B+ U.N.O. A S3 5. 4.. 1, 9g,. 3. 28„ - 5' 0" 5'-0" 5'-10" L 6-0" L 6-0" L 3'-10" Z-104" L 5'-116a" 5'-0" FOUNDATION PLAN MONO ELEV-Al SCALE: %4"=V-0" NOTE: • WHERE PROJECT IS TO BE LOCATED IN KNOWN RADON GAS PREVALENT AREAS, APPENDIX "F" OF THE FLORIDA BUILDING CODE 7TH EDITION (2020) RESIDENTIAL IS TO BE IMPLEMENTED. CONCRETE STRENGTH IN THESE AREAS TO BE A MINIMUM OF 3000 P.S.I. THEREFORE, ANY AND ALL NOTES ON THESE PLANS THAT INDICATED 2500 P.S.I. SHALL BE REPLACED WITH 3000 P.S.I. FOR THE CONCRETE STRENGTH • SEE SHEET SN FOR SOIL & TERMITE NOTES. BORATE / BORACARE TREATED LUMBER IS AN ALTERNATE TERMITE PROTECTION TO SOIL POISONING WWF PLACED IN 1/8" WIDE SAW CUT AT UPPER 1/3 OF SLAB C.J. LINES SHOWN ON OR FIBERMESH FOUNDATION PLAN REINF. SEE PLAN. w Z Uj a 1" MIN. OR 1/4 SLA THICKNESS, WHICHEVER IS GREATER CONTROL JOINT DETAIL SCALE: 3/4" = V-0" REV. 5-2-24 #5 CONTINUOUS REINF. SEE FND. FOR QUANTITY #5 X 25" X 25" CORNER BAR ONE FOR EA. L HORIZ. REBAR, TYP. U.N.O. L I.• •• **Alternate: i 1 ' The reinf. bars shall be cont. around corner by cold bending the bar w/ min. bar lap of 25". TYP. CORNER BAR DETAIL SCALE: 3/4" = V-0" o cvCD Q o ® • Qa� O C N ]C o, a 0 E� ,art LUW"n C a on Ai ro E 0 =3aU t: o 5 CV co: 0 To the best of the Engineers knowledge, information and belief, the structural plans and specifications contained within these drawings comply with the 2020 Florida Building Code - Residential 7th Edition. Engineers signature and seal is only for the structural engineering portions of the drawing pages bearing Engineers signature and seal. N W Q YYpp�11 OO O U N W C V N O c: # C .7 � op N � LL IJL Q 6 d Y m LL LL U z Z 0 m c rn 0 = t nio O W M LuW W ^ ¢ m rn rn °' J z LLffic� Z 0 C'�6,,111 (h Z U G H z N OU ❑❑❑ Z W z � o g z � � s Q N rJ o � cn (� w Q 0 ) V) �N w C N .03 0011116 U di W J _ E _ m 8 i "! Z y � .. U O N Q Y 0 N O) 0 �. m M n 2 Z J OC,i =o >n Z, a O cEv zE w ¢ UO (—'11II cu �2 _ �2'Z mo Z §z ? Z O aU m Q 4 = r c� <Q �o M d' Z4 a 03 >(O L i Ol 00 (0 O r O J T Cr Y U) o M m Q� O N o N n � L(') •— Q T E c 00 `^ o Z co Z E ri C cc d U _j Q 0 c J JOB NO: 22-04746 SCALE : AS NOTED SHEET NO. 6 ENGINEERED CLADDING W NDFPR PRESSURES ANDOSUUCTIONIS FORM AN ROOFOHEIGHT <_T 5 ftND RSH ✓IND SPEED (ULTIMATE) 140.0 MPH ✓IND SPEED (ALLOWABLE) 108.4 MPH XPOSURE CATEGORY C EFFECTIVE WIND PRESSURE AND SUCTION (PSF) HIP ROOF >20 TO 45 DEG. WIND AREA (+) VALUE DENOTES PRESSURE (SQ FEET) (-) VALUE DENOTES SUCTION [4:12]-[12:12] a=oft AREA ROOF 1 2e 2n 2r 3 3e 3r 10 HIP -35.94 -49.57 -49.57 -49.57 GABLE -38.22 -38.22 -60.99 -60.99 -60.99 -78.58 ROOF NAILING SCHEDULE/ NAILING ZONES (SHINGLE AND TILE): ZONE 1: ASTM F1667 RSRS-01 (8d) NAILS @ 6" O.C. ON EDGE AND 6" O.0 IN FIELD ZONE 2e, 2n, 2r: ASTM F1667 RSRS-01 (8d) NAILS @ 4" O.C. ON EDGE AND 4" O.0 IN FIELD ZONE 3, 3e, 3r: ASTM F1667 RSRS-01 (8d) NAILS @ 4" O.C. ON EDGE AND 4" O.0 IN FIELD ROOF SHEATHING: SHINGLE: %s' EXP. 1 (24/6) or'Y32' EXP. 1 (32116) TILE: tY32" EXP. 1 (33/16) NOTE: 1. PER CODE ASTM F1667 RSRS-01 REFERENCE TO 8d (2 Y8" x 0.113") NAILS t 2. WHERE THE SHEATHING THICKNESS IS GREATER THAN 1Y32', SHEATHING SHALL BE FASTENED WITH ASTM F1667 RSRS-03 10d (2%:" x 0.131") NAILS OR ASTM F1667 RSRS-04 (3" x .120") NAILS 3. GABLES- DROP GABLE END & (1) ADDITIONAL DROPPED TRUSS 2x4 #2 SYP OUTLOOKER RAFTER W/ BLOCKING @ 16" O.C. IF NO DROPPED GABLE END, ATTACH 2x4 #2 SYP BLOCKING @ 16" O.0 FIRST 4 BAYS WITH (2) 12d NAILS EA. END. ATTACH ROOF SHEATHING TO RAFTERS W/ BLOCKING PER NAILING SCHEDULE. rn x e v rn L0 c O J 0 I U 3 Cn I LO LO L v 0 J I N L0 LO cn 0 .c 3 N CD v c C y C N U d LP d t� N N 0 N N t to v a 0 0 U Z W m v a=oft GABLE ROOF > 20 TO 45 DEG. [4:12]-[12:12] UPLIFT CONNECTION CROSS-REFERENCE MARK SIMPSON STRONG TIE USP MANUFACTURING, INC. Q CONNECTOR CAPACITY FASTENERS CONNECTOR CAPACITY FASTENERS SYP SPF SYP SPF A META12 1420 9 - 10d x 1 1/2" HTA20 1870 1585 10 - 10d x 1 1/2" A (2) (2)META12 1875 (1)PLY 1795 (2)PLY 9 - 10d x 1 1/2" B HETA16 1810 9 - 10d x 1 1/2" HTA16 1870 1585 10 - 10d x 1 1/2" C H2.5A 565 535 10 - 8d RT7A 585 515 10 - 8d x 1 1/2" D H3 400 320 8 - 8d RT3 345 305 8 - 8d x 1 1/2" E META20 1450 7 - 10d x 1 1/2" HTA20-18 1625 1400 10 - 10d x 1 112" F HHETA20 2120 10 - 10d x 1 1/2" HTTA20 2375 11 - 10d x 1 1/2" G H10A 1040 1015 18 - 10d x 1 1/2" RT16A 1020 1160 9 - 10d x 1 1/2"& 8-10d H FGTR 4725 3400 w/ (18) 1/4" x 3" SDS WOOD SCREWS AND (2) 1/2" x 5" TITEN HD ACHOR BOLTS RFUS 7100 --- w/ (12) WS3 WOOD SCREWS AND (4) 3/4" x 6" WEDGE -BOLTS J HTT5 4350 3740 5/8" ANCH. / (26) 10dx1-1/2" HTT5 5795 5/8" ANCH. /(26) 10d x1-1/2 K HD3B * 3130 3050 5/8" DIA. BOLTS TDX2-TZ 3295 --- 2 - 5/8" DIA. BOLTS L VGT R/L 2225 1600 w/ (16) 1/4" x 3" SDS WOOD SCREWS AND HDU4-SDS2.5 w/ (10) 1/4" X 2 1/2" SDS WOOD SCREWS & (1) 5/8" ATR M VGT - F 4940 3555 w/ (16) 1/4" x 3" SDS WOOD SCREWS AND HDU4-SDS2.5 w/ (10) 1/4" x 2 1/2" SDS WOOD SCREWS & (1) 5/8" ATR N LUS26 1165/1060 ** 1005/915 ** 8 - 10d x 3" JUS26 1000/1080** --- 8-10d P HUS26 1320/3235 ** 1335/2820 ** 20 - 16d x 3 1/2" HUS26 2035/3400 --- (20)16d x 3-1/2" Q HUS28 1760/4095 ** 1720/3125 ** 30 - 16d x 3 1/2" HUS28 2950/5090 --- 30d -16d x 3-1/2" R MTS12 990 860 14 - 10d x 1 1/2" MTW12 1195 1005 14-10d x 1-1/2" S VGT - M 4940 3555 w/ (16) 1/4" x 3" SDS WOOD SCREWS AND (1) 5/8" ATR EPDXIED w/ SIMPSON SET w/ 12" MIN. EMBEDMENT. T (2) LGT3 6570-M 6960-F 4730-M 5010-F w/ (24) 1/4" x 3" SDS SCREWS & (8) 3/8" x 5" TITEN HD (2 PLY) OR (52) 16D SINKERS FOR FRAME U MGT 3965 3330 22 -10d x (1) 5/8" ATR wl 12" EMBED w/ SIMPSON "SET" EPDXY MUGT15 4175 22 -10d x (1) 5/8" ATR w/ 12" EMBED w/ USP CIA-7000C EPDXY V (2) LGT2 4060-M 3770-F 3500-M 3240-F w/ I (14) 1/4" x 2 1/4" TITENS (2 PLY) OR (28) 16D SINKERS FOR FRAME LUGT2 3100-M 4520-F 3100-M 3800-F w/ (32) 16D SINKERS & (10) 1/4" x 3" WEDGE- BOLTS (2-PLY) OR (32) 16 SINKERS FOR FRAME "X" HTS 20 1310 1245 24-10d x 1 1/2" HTW20 1530 1285 24-10d x 1 1/2" SP1 555 535 10 - 10d SPT22 735 8 - 10d SP2 1010 605 12 - 10d SPT24 1090 12 - 10d HCP2 1 590 1 555 12-10d x 1 1/2" HHCP2 1 680 570 1 (20)10d x 1-1/2" * MINIMUM 3" MEMBER ** REACTIONS ARE FOR ROOF LOADS ONLY *** DO NOT DRIVE NAILS THROUGH THE TRUSS PLATE ON THE OPPOSITE SIDE OF THE TRUSS, WHICH COULD FORCE THE PLATE OFF OF THE TRUSS. ALL EPDXY ANCHORS SHALL USE SIMPSON "SET" OR USP CIA-7000C (SEE MANUFACTURES SPECS) NOTE: DOUBLE FELT REQ'D ON ROOF PITCHES 3/12 & LOWER. REVISED 12-02-20 LOADS -- ROOF = L 1360 FLOOR = L / 480 W/ 3/8" MAX DEFLECTION. FLOOR JOIST SPACING SHALL BE MAX OF 19.2" OC FOR HARDWOOD & TILE AREA'S & 24" OC FOR CARPET AREA'S DROP HIP DETAIL 2-0-0 MAXIUM SPACING ON VERTICALS OF (B) TRUSS (B) (A) I OR 2 PLY CARRIER 1-8-8 CLEAR GAP BETWEEN (B) TRUSSES (+/- 6") 'FASTEN EACH (B) TRUSS WEB TO EACH (A) TRUSS TOP CHORD @EVERY INTERSECTING POINT SHOWN ON THE HIP TRUSS SYSTEM BELOW. FASTEN TOP CHORDS OF EACH (B) (B TRUSS TO THE TOP CHORDS OF (A) TRUSSES AT EVERY OTHER INTERSECTING POINT I-). INTERSECTING POINT TO BE FASTENED WITH 2 -16d COMMON NAILS OR 0.128" x Y GUN NAILS. FASTEN BOTTOM CHORD OF (B) TRUSS TO TOP CHORD OF CARRIER TRUSS WITH THE SAME SPECIFIED COMMON NAILS OR GUN NAILS AT 48" OC. (+) IN LIEU OF PREFABRICATED HIP PLANING TRUSSES, (8) 2x4 SO. PINE #2 OR #2 PT. STICK LUMBER (LAID FLAT WISE) MAY BE USED. FOLLOW FASTENING SCHEDULE AS DEFINED FOR HIP PLANING TRUSSES. R1 STICK FRAMING SPLICING IS ALLOWED BETWEEN TRUSSES OR AT TRUSS '551 O (A) INTERSECTIONS. SPLICING TO BE STAGGERED BETWEEN COMMON TRUSSES, NO CATS REQUIRED UNDER STICK FRAMING SPLICING. MINIMUM LENGTH OF STICK FRAMING TO BE 5'-0" ON A HORIZONTAL PROJECTION. NOTE: SEE SHEET D1 FOR ROOF FRAMING DETAILS (2) -12d TOENAILS EACH SIDE OF FLOOR TRUSS TO WALL OR BEAM BELOW. TYP. AT INTERIOR BEARING U.N.O. CaD LL IKV CN FX CONT LEDGER) 0LL 0 E3 0 Cti ) Cr LO 00 0 SEE SHEET D1 FOR ROOF FRAMING DETAILS FRAMING PLAN — ELEV-Al SCALE: Y4"=1'-0" .a- Q 2 N � r � 5 o r� To the best of the Engineers knowledge, information and belief, the structural plans and specifications contained within these drawings comply with the 2020 Florida Building Code - Residential 7th Edition. Engineers signature and seal is only for the structural engineering portions of the drawing pages bearing Engineers signature and seal. N QE $ N rnrNiv� M a LL a a JLLLL 0 Z z � mcrn GENERAL INSTALLATION NOTES 1. Provide full mortar head and bed joints. 2. Shore filled lintels as required. 3. Installation of lintel must comply with the architectural and/or structural drawings. 4. U-Lintels are manufactured with 5-1/2" long notches at the ends to accommodate vertical cell reinforcing and grouting. 5. All lintels meet or exceed U360 vertical deflection, except lintels 17'-4" and longer with a nominal height of 8" meet or exceed U180. 6. Bottom field added rebar to be located at the bottom of the lintel cavity. 7, 7/32" diameter wire stirrups are welded to the bottom steel for mechanical anchorage. 8. Cast -in -place concrete may be provided in composite lintel in lieu of concrete masonry units. 9. Safe load ratings based on rational design analysis per ACI 318 and ACI 530 10. Product Approvals: Miami Dade County, Florida Nos.20-0630.16 and 20-0630.15. it. The exterior surface of lintels installed in exterior concrete masonry walls shall have a coating of stucco applied in accordance with ASTM C-926 or other approved coating. 12. Lintels loaded simultaneously with veritcal (gravity and uplift) and horizontal (lateral) loads shoud be checked for combine loading with the following equation: Applied vertical load Applied horizontal load / . O Safe vertical load + Safe horizontal load \— GENERAL CONCRETE LINTEL SCHEDULE APPROVED LINTEL MANUFACTURERS: CASTE-CRETE, QUALITY, LOTTS 0 0 0 0 8F8-1B/1T 8F8-0B/1T 8RF6-OB/1T ;' f O © © O o O O 0 0 8RF14-1B/1T 8RF14-0B11T 81`16-OB/1 C OD FO 8F44 1 B/1 T 8F40 1 B/1 T 8RF40 OB/1 T 8F32 1 B/1T FORM & GROUT SOLID v ,. - W CV Q o U 0 ps BAR CONT. 8F12-1 B/1T O W" LINTEL DETAIL SCALE = N.T.S. M NONE TYPE DESIGNATION #5RE MIN( BAR ATTOP ALTERNATE ALTERNATE POWERS F=FILLED WITH GROUT / U = UNFILLED R=RECESSED CLEAR STEEL LINTEL a ° QTY. OF #5 0 ° REBAR @ BOTTOM ° OF LINTEL CAVITY a ' M.U. #5 REBAR AT TOP Q w_ ° ` ° MIN. (1) REQ'D 1-1/2" CLEAR 8 F 16— B/ 1 T � oo o z ° o GROUT D n J tNOMINAL.QUANTITY OF ° 5 REBAR AT o = _ U) w U) C.M.U. WIDTH #5 REBAR AT a o BOTTOM OF a z ED O TOP LINTEL CAVITY n �LU UFONOMINA "*-BOTTOM O Ir, U ~ HEIGHT REINFORCING a ¢ 0 z 7-5l8"ACTUAL PROVIDED IN Z LL O w f 8" NOMINAL WIDTH LINTEL Q O 3 m 4AS 15 REBAR AT BOTTC INDICATED (VARIES) of uZ ¢ a MATERIALS-16 GAUGE POWERS c precas intels = 3500 psi. STEEL BOXED LINTEL 2, fc prestressed lintels = 6000 psi. 3. grouted per ASTM C476 fg = 3000 psi w/ POWERS STEEL BOXED LINTEL NOTES (ALT.) 4. maximum 3/8" aggregate and 8" to 11" slump. 5. Concrete masonry units (CMU) per ASTM C90 w/ ONLY IF NOTED ON LINTEL PLAN minimum net area compressive strength = 1900 psi. 1. Refer to manufacturer's specifications for installation. 6. Reber per ASTM A615 Grade 60. Prestressing strand per ASTM A416 grade 2. Contractor to provide proper protection of lintel to prevent rusting. 7. 270 low relaxation. Refer to manufacturer's specifications. 7/32 wire per ASTM A510. 3. If lintel is scratched or damaged refer to Powers Steel for repair. 8. Mortar per ASTM C270 type M or S. 4. Lintel depth to match precast depth. One #5 Bar required at top see lintel plan/details for bottom steel required. 5. A bonding agent must be applied to the Steel Box lintels prior to LINTEL MINIMUM DEPTHS ARE CALLED OUT ON LINTEL PLAN. IF CONTRACTOR INSTALLS A DEEPER LINTEL THAN INDICATED ON THE PLAN, DOING THIS INCREASES THE STRENGTH OF THE LINTEL AND IS applying the cementibuos coating. See contractor specifications APPROVED WITHOUT ENGINEERING LETTER. IF A SMALLER LINTEL IS INSTALLED CONTACT E.O.R. FOR APPROVAL. (SEE LINTEL PLAN FOR SCHEDULE) LINTEL PLAN NOTES: 1. THIS PLAN IS TO BE USED FOR STRUCTURAL INFORMATION ONLY. 2. UNLESS NOTED OTHERWISE ALL LINTEL DEPTHS ARE TO BE ASSUMED TO BE 16" MINIMUM DEPTH. 3. THE NUMBER OF COURSES OF MASONRY REQUIRED BETWEEN THE LINTEL & THE BOND BEAM SHOULD BE COORDINATED WITH THE ELEVATION DRAWINGS 4. THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING THE PROPER LINTEL HEIGHT. 5. LINTELS AT GARAGE DOOR OPENING ARE MINIMUM DEPTH REQUIRED FOR THE DESIGN LOADS. THE DEPTH MAY BE INCREASED IF REQUIRED FOR PROPER LINTEL HEIGHT,G.C. COORDINATE. POWER STEEL LINTEL IS AN ADEQUATE SUBSTITUTION @ALL LOCATIONS UNLESS NOTED OTHERWISE AT OPENING LOCATION F F 4'-6" LL 4'-6" LL E 5'-10" LL LINTEL PLAN - ELEV-Al SCALE: %4"=1'-0" - N 3 i' N '5 �yy yt l -- C2 " W44 y r . N '✓ �r-4 to _ m � To the best of the Engineer's knowledge, information and belief, the structural plans and specifications contained within these drawings comply with the 2020 Florida Building Code - Residential 7th Edition. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal, 0 W Q E S N O 0 N O 01 O N n N T p it C c J 7 U7 � � � � LL fA rq"�� w dl Q 13 M 0 2s2S 0 d JLLLL 5 i Y Z SS ZZz � Z Z IW t@ v O 0 r O W j (6 N C0 ¢] J Q J 0 Z Z ILN 00 0 0 Cl) Z F Z OU ❑11❑ W N M m n d N V)., � 0 1W `o LL T U> w ° U IOI ^ vI w �a N � 3 ~ _\tl7Mf U c J H 8 �I WM L d U p m C W Y N 1Iffil 0 m M � z LL z o m ao E 0; E 0 oo -Z m H rJ �� o J w cn C 10 a� � g �z 4 O U:) O m �z ~ ~ o M OQ a 03 �t N O > C0 LrOLO m Q (D 00 CO O T G O Y C^r T� V / W m I .Q CV LO r Q CD T E c o Z tU Z � E �--� N u, m @ d E U -i -o Q c c _J JOB NO: 22-04746 SCALE : AS NOTED SHEET NO. 8 _I _- _ 1. 11 1 -!___ I. I I I I I"fM , 1 NOTE: BORATE/ SENTRA CON SYSTEM APPLIED TO ALL FRAME MEMBERS WITHIN 24" A.F.F. 1) METHOD OF TREATMENT SHALL BE APPROVED BY THE GOVERNING JURISDICTION "LIQUID BORATE OR BOR-A-COR" PRODUCT METHODS MUST BE DETERMINED AT PERMIT STAGE. 2) PRESSURE TREATED LUMBER THAT HAS BEEN CUT OR DRILLED THAT EXPOSES UNTREATED PORTIONS OF WOOD ARE REQUIRED TO BE FIELD TREATED TO PREVENT INSECT INFESTATION. ATTENTION: CHEMICAL CHANGES IN PRESSURE TREATED WOODS AS OF DECEMBER 31ST, 2003, CHROMATED COPPER ARSENATE (CCA-C) WILL NO LONGER BE PRODUCED FOR RESIDENTIAL OR GENERAL CONSUMER USE. SEVERAL NEW PRESSURE TREATED WOOD ALTERNATIVES HAVE BEEN CREATED TO REPLACE CCA-C. MANY OF THE NEW PRESSURE TREATED WOODS USE CHEMICALS THAT ARE CORROSIVE TO STEEL. IT IS THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THE TYPE OF WOOD TREATMENT AND TO SELECT APPROPRIATE CONNECTORS THAT RESIST CORROSION. FOR EXAMPLE, ACQ-C, ACQ-D, CBA-A, OR CA-B REQUIRE HOT -DIPPED GALVANIZED OR STAINLESS STEEL FASTENERS. DOT SODIUM BORATE (SBX) DOES NOT. REQUIRED SAFETY GLAZING IN HAZARDOUS LOCATIONS (RE: FBRC R308.4) R308.3 HUMAN IMPACT LOADS. INDIVIDUAL GLAZED AREAS INCLUDING GLASS MIRRORS IN HAZARDOUS LOCATIONS SUCH AS THOSE INDICATED AS DEFINED IN SECTION R308.4 SHALL PASS THE TEST REQUIREMENTS OF SECTION R308.3.1. GLAZING SHALL BE TESTED IN ACCORDANCE WITH CPSC 16 CFR, PART 1201 CRITERIA FOR CATEGORY I OR CATEGORY II AS INDICATED IN TABLE R308.3.1(1). EXCEPTIONS: 1. POLISHED WIRED GLASS FOR USE IN FIRE DOORS AND OTHER FIRE RESISTANT LOCATIONS SHALL COMPANY WITH ANSI Z97.1-14 2. LOUVERED WINDOWS AND JALOUSIES SHALL COMPANY WITH SECTION R308.2 R308.4 HAZARDOUS LOCATIONS. THE FOLLOWING SHALL BE CONSIDERED SPECIFIC HAZARDOUS LOCATIONS FOR THE PURPOSE OF GLAZING: 1. GLAZING IN SWINGING DOORS EXCEPT JALOUSIES. 2. GLAZING IN FIXED AND SLIDING PANELS OF SLIDING DOOR ASSEMBLIES AND PANELS IN SLIDING AND BIFOLD CLOSET DOOR ASSEMBLIES. 3. GLAZING IN STORM DOORS. 4. GLAZING IN ALL UNFRAMED SWINGING DOORS. 5. GLAZING IN DOORS AND ENCLOSURES FOR HOT TUBS, WHIRLPOOLS, SAUNAS, STEAM ROOMS, BATHTUBS, AND SHOWERS. EXPOSED EDGE OF GLAZING IN ANY PART OF A BUILDING WALL ENCLOSING THESE COMPARTMENTS WHERE THE BOTTOM THE GLAZING IS LESS THAN 60 INCHES (1524MM) MEASURED VERTICALLY ABOVE ANY STANDING OR WALKING SURFACE. 6. GLAZING, IN AN INDIVIDUAL FIXED OR OPERABLE PANEL ADJACENT TO A DOOR WHERE THE NEAREST VERTICAL EDGE IS WITHIN A 244NCH(610MM) ARC OF THE DOOR IN A CLOSED POSITION AND WHOSE BOTTOM EDGE IS LESS THAN 60 INCHES (1524MM) ABOVE THE FLOOR OR WALKING SURFACE. 7. GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL, OTHER THAN THOSE LOCATIONS DESCRIBED IN ITEMS 5 AND 6 ABOVE, THAT MEETS ALL OF THE FOLLOWING CONDITIONS: 7.1 EXPOSED AREA OF AN INDIVIDUAL PANE GREATER THAN 9 SQUARE FEET (0.836 M2). 7.2 BOTTOM EDGE LESS THAN 18 INCHES (457 MM) ABOVE THE FLOOR. 7.3 TOP EDGE GREATER THAN 36 INCHES (914 MM) ABOVE THE FLOOR. 7.4 ONE OR MORE WALKING SURFACES WITHIN 36 INCHES (914 MM) HORIZONTALLY OF THE GLAZING. 8. ALL GLAZING IN RAILINGS REGARDLESS OF AN AREA OR HEIGHT ABOVE WALKING SURFACE. INCLUDED ARE STRUCTURAL BALUSTER PANELS AND NONSTRUCTURAL IN FILL -PANELS. 9. GLAZING IN WALLS AND FENCES ENCLOSING INDOOR AND OUTDOOR SWIMMING POOLS, HOT TUBS AND SPAS WHERE THE BOTTOM EDGE OF THE GLAZING IS LESS THAN 60 INCHES (1524 MM) ABOVE A WALKING SURFACE AND WITHIN 60 INCHES (1524 MM) HORIZONTALLY OF THE WATER'S EDGE. THIS SHALL APPLY TO SINGLE GLAZING AND ALL PANES IN MULTIPLE GLAZING. 10. GLAZING ADJACENT TO STAIRWAYS, LANDINGS, AND RAMPS WITHIN 36 INCHES (914 MM) HORIZONTALLY OF A WALKING SURFACE WHEN THE EXPOSED SURFACE OF THE GLASS IS LESS THAN 60 INCHES (1524 MM) ABOVE THE PLANE OF THE ADJACENT WALKING SURFACE. 11. GLAZING ADJACENT TO STAIRWAYS WITHIN 60 INCHES (1524 MM) HORIZONTALLY OF THE BOTTOM TREAD OF A STAIRWAY IN ANY DIRECTION WHEN THE EXPOSED SURFACE OF THE GLASS IS LESS THAN 60 INCHES (1524 MM) ABOVE THE NOSE OF THE TREAD. EXCEPTION: THE FOLLOWING PRODUCTS, MATERIALS AND USES ARE EXEMPT FROM THE ABOVE HAZARDOUS LOCATIONS: 1. OPENINGS IN DOORS THROUGH WHICH A 3-INCH(76 MM) SPHERE IS UNABLE TO PASS. 2. DECORATIVE GLASS IN ITEMS 1, 6 OR 7. 3. GLAZING IN SECTION R308.4.2, ITEM 2-EXCEPTIONS, WHEN THERE IS AN INTERVENING WALL OR OTHER PERMANENT BARRIER BETWEEN THE DOOR AND THE GLAZING. 4. GLAZING IN SECTION R 308.4.2, ITEM 3, WHERE ACCESS THROUGH THE DOOR IS TO A CLOSET OR STORAGE AREA 3 FEET (914 MM) OR LESS IN DEPTH. GLAZING IN THESE APPLICATIONS SHALL COMPANY WITH SECTION R308.4.3. 5. GLAZING IN SECTION R308.4.3, ITEM 2-EXCEPTIONS, WHEN A PROTECTIVE BAR IS INSTALLED ON THESE ACCESSIBLE SIDE(S) OF THE GLAZING 36 INCHES ± 2 INCHES (914 ± MM 51 MM) ABOVE THE FLOOR. THE BAR SHALL BE CAPABLE OF WITHSTANDING A HORIZONTAL LOAD OF 50 POUNDS PER LINEAR FOOT KG/M) WITHOUT CONTACTING THE GLASS AND BE A MINIMUM OF 1 Y2INCHES (38 MM) IN CROSS SECTIONAL HEIGHT. 6. OUTBOARD PANES IN INSULATING GLASS UNITS AND OTHER MULTIPLE GLAZED PANELS IN SECTION R308.4.3, ITEM 3-EXCEPTIONS, WHEN THE BOTTOM EDGE OF THE GLASS IS 25 FEET (7620 MM) OR MORE ABOVE GRADE, A ROOF, WALKING SURFACES, OR OTHER HORIZONTAL [WITHIN 45 DEGREES (0.79 RAD) OF HORIZONTAL] SURFACE ADJACENT TO THE GLASS EXTERIOR. 7. MIRRORS AND OTHER GLASS PANELS MOUNTED OR HUNG ON A SURFACE THAT PROVIDES A CONTINUOUS BACKING SUPPORT. 8. SAFETY GLAZING IN SECTION R308.4, IS NOT REQUIRED WHERE: 8.1 THE SIDE OF STAIRWAY, LANDING OR RAMP HAS A GUARDRAIL OR HANDRAIL, INCLUDING BALUSTERS OR IN -FILL PANELS, COMPLYING WITH THE PREVISIONS OF; AND 8.2 THE PLANE OF THE GLASS IS GREATER THEN 18 INCHES (457 MM) FROM THE RAILING. 1. SPECIFICATIONS 1.1. CONSTRUCTION: 1. 1, 1. ACI 318-14 BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE 1.1.2. ACI 530-13, ASCE 5/TMS 402-16 & ACI 530.1-13, ASCE 6/TMS 602-16 SPECIFICATIONS FOR MASONRY STRUCTURES. 1. 1. 3. ASTM C270-14A, C90-14 & C91-05 SPECIFICATIONS FOR MASONRY STRUCTURES 1.1.4. NATIONAL DESIGN SPECIFICATIONS (NDS) FOR WOOD CONSTRUCTION, 2018 EDITION, AND ALL ACCOMPANYING SUPPLEMENTS. 1.1.5. FLORIDA BUILDING CODE 7TH EDITION (2020) RESIDENTIAL 1.1.6. "MANUAL OF STEEL CONSTRUCTION, ALLOWABLE STRESS DESIGN", BY THE AMERICAN INSTITUTE OF STEEL CONSTRUCTION, (AISC) 15TH EDITION. 1.1.7. "DESIGN SPECIFICATION FOR LIGHT METAL PLATE CONNECTED WOOD TRUSSES" BY THE TRUSS PLATE INSTITUTE TRI1-14. 1.2. DESIGN: 1.2.1. ACI 301-16 BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE 1.2.2. ACI 530-16, ASCE 5/TMS 402-16 & ACI 530.1-16, ASCE 6/TMS 602-16 SPECIFICATIONS FOR MASONRY STRUCTURES. 1.2.3. ASTM C270-14A, C90-14 & C91-05 SPECIFICATIONS FOR MASONRY STRUCTURES 1.2.4. NATIONAL DESIGN SPECIFICATIONS (NDS) FOR WOOD CONSTRUCTION, 2018 EDITION, AND ALL ACCOMPANYING SUPPLEMENTS. 1.2.5. PLYWOOD DESIGN SPECIFICATIONS (APA) 1.2.6. FLORIDA BUILDING CODE (FBC) 7TH EDITION (2020) AND FLORIDA BUILDING CODE 7TH EDITION RESIDENTIAL (FBCR) 1.3. SHOP DRAWINGS: 1. 3. 1. THERE SHALL NOT BE ANY DEVIATIONS FROM THESE DESIGN PLANS BY OTHERS DURING THE PREPARATION OF SHOP DRAWINGS WITHOUT WRITTEN APPROVAL FROM THE ENGINEER OF RECORD. 1.3.2. ALL SHOP DRAWINGS ARE TO BE SUBMITTED TO THE ENGINEER OF RECORD PRIOR TO THE COMMENCEMENT OF CONSTRUCTION. 1.3.3. ALL ROOF AND FLOOR TRUSS SHOP DRAWINGS ARE TO BE SIGNED AND SEALED BY A FLA. REG. PE. AND SHALL INCLUDE: DRAWINGS AND CALCULATIONS, REACTIONS AND BEARING POINTS, BRACING REQUIREMENTS, AND CONNECTIONS TO SUPPORTING TRUSS MEMBERS. 2. DESIGN LOADS 2.1. DEAD LOADS: 2. 1. 1. UNIT WEIGHT OF SOIL, COMPACTED: 120 PCF 2.1.2. UNIT WEIGHT OF REINFORCED CONCRETE: 150 PCF 2.1.3. UNIT WEIGHT OF 8" C.M.U. BLOCK: 55 PSF 2.1.4. 1ST FLOOR SUPERIMPOSED LOAD: 20 PSF 2. 1. 5. UNIT WEIGHT OF 2x4 PARTITION WALLS: 11 PSF 2.1.6. UNIT WEIGHT OF 2x6 BEARING WALLS: 12 PSF 2.1.7. BALCONIES & DECKS: 15 PSF 2. 1.8. TILE ROOF TOP CHORD : 15 PSF BOTTOM CHORD: 10 PSF 2.1.9. SHINGLE ROOF TOP CHORD : 7 PSF BOTTOM CHORD: 10 PSF 2. 1. 10. FLOOR TRUSSES 15 2.2. LIVE LOADS: 2.2.1. SIDEWALK AND DRIVEWAY LOAD: 250 PSF 2.2.2. GARAGE LOADS : 40 PSF 2.2.3. PARTITIONED ROOMS: 40 PSF 2.2.4. BALCONY AND DECKS: 60 PSF-UNDER 100 sq. ft. 2.2.5. STAIRWAYS AND LANDINGS : 40 PSF 2.2.6. SLEEPING ROOMS: 30 PSF 2.2.7. FLOOR TRUSS TOP CHORD MINIMUM: 40 PSF 2.2.8. ROOF TRUSS TOP CHORD MINIMUM: 20 PSF BOTTOM CHORD (ATTIC W/O LIMITED STORAGE) : 10 PSF (NON -CONCURRENT) BOTTOM CHORD (ATTIC W/ LIMITED STORAGE) : 20 PSF 2.3. RAILING LOADS: 2. 3. 1. ALL RAILING AND GUARD RAIL SYSTEM'S ARE TO BE DESIGNED TO WITHSTAND A CONCENTRATED LOAD OF 200 POUNDS APPLIED AT ANY POINT AND IN ANY DIRECTION ON THE RAILING. 2.3.2. ALL RAILING AND GUARD RAIL SYSTEM'S ARE TO BE DESIGNED TO WITHSTAND A HORIZONTAL LOAD OF 50 PLF ON THE GUARDRAIL AND A SIMULTANEOUS LOAD 00 P F OF 1 APPLIED VERTICALLY DOWNWARD AT THE TOP OF THE GUARDRAIL L 2.3.3. GUARDRAIL SYSTEM SHALL BE DESIGNED TO WITHSTAND 2001b CONCENTRATED HORIZONTAL LOAD APPLIED ON 1 SQ. FT. AT ANY POINT IN THE SYSTEM. 2.3.4. 2.3.1., 2.3.2 & 2.3.3. ARE NOT REQUIRED TO BE APPLIED SIMULTANEOUSLY, BUT EACH SHALL BE APPLIED TO PRODUCE THE MAXIMUM STRESSES IN THE MEMBER COMPONENTS. 2.4. WIND LOADS: 2.4.1. WIND DESIGN TO BE CONDUCTED IN ACCORDANCE WITH SECT. R301.2 OF THE FLORIDA BUILDING CODE 7TH EDITION (2020) RESIDENTIAL, AND CONDUCTED BASED ON A 140 MPH 3 SECOND GUST, EXPOSURE "C", IMPORTANCE FACTOR"[" =1.0. ENCLOSED BUILDING 2.4.2. NET UPLIFT DEAD LOADS -10 PSF SHINGLE, 15 PSF TILE 2.4.3. WIND LOAD DETERMINATION BASED ON ASCE/SEI 7-16 2.5. DEFLECTIONS: 2.6.1. FLOOR TRUSSES SHALL LIMIT DEFLECTION TO U480TIMES THE SPAN FOR LIVE LOADS AND U240 TIMES THE SPAN FOR TOTAL LOAD. 3. DESIGN METHOD 3.1. LOAD FACTOR DESIGN: THE LOAD FACTOR DESIGN METHOD WAS USED TO DESIGN: CAST -IN -PLACE CONCRETE SLABS AND FOOTINGS 3.2. SERVICE LOAD DESIGN: 3.2.1. THE SERVICE LOAD DESIGN METHOD WAS USED TO DESIGN: MASONRY WALLS AND LINTELS INTERIOR AND EXTERIOR WOOD FRAMING AND SHEATHING STAIRS AND FLOOR FRAMING ROOF FRAMING, SHEATHING AND UPLIFT 3.3. LOAD COMBINATIONS FOR LRFD DESIGNS: 3.3.1. THE FOLLOWING LOAD COMBINATIONS WERE DESIGNED FOR: TOTAL DL + FLOOR LL + ROOF LL TOTAL DL + FLOOR LL + WL TOTAL DL + WL 3.3.2. ALL ROOF AND FLOOR TRUSSES SHALL BE DESIGNED TO RESIST THE WORST LOAD COMBINATION RESULTING IN THE MAXIMUM STRESSES PLACED ON THAT COMPONENT. BOTH PARTIAL, FULL, AND ALTERNATING SPAN LOADING ARE TO BE CONSIDERED. 3.4. DESIGN ASSUMPTIONS: 3.4.1. ALL FOUNDATIONS ARE CENTERED UNDER SUPPORTED COLUMNS AND WALLS UNLESS SHOWN OTHERWISE IN THE DESIGN PLANS. 4. MATERIALS 4.1. REINFORCING STEEL: 4. 1. 1. REINFORCING STEEL SHALL BE ASTM A615 / A615M-12 MIN. GRADE 40, fy = 40 Ksi 4. 1. 2• LAP SPLICE SHALL BE AS FOLLOWS: #5 BAR 25", #4 BAR 20", #3 BAR 20". 4. 1. 3. ALL DIMENSIONS PERTAINING TO THE LOCATION OF REINFORCING ARE TO THE CENTERLINE OF EACH BAR EXCEPT WHERE THE COVER DIMENSION IS SHOWN TO THE FACE OF THE CONCRETE. 4.1.4. REINFORCING DETAIL DIMENSIONS ARE OUT TO OUT OF BARS. 4. 1. 5. REINFORCING MECHANICAL COUPLERS ARE TO DEVELOP 125% OF THE REQUIRED YIELD STRENGTH OF THE BAR AND ARE TO BE APPROVED BY THE ENGINEER OF RECORD. 4. 1. 6. DESIGN COVER REQUIREMENTS: C-I-P CONCRETE FORMED AGAINST EARTH: C-I-P CONCRETE EXPOSED TO EXTERIOR: C-I-P CONCRETE NOT EXPOSED: GROUT FILLED MASONRY: 4. 1. 7. WELDED WIRE FABRIC (WWF): ASTM A-185 / A 185M-14 4.1.8. DETAIL REINFORCEMENT IN ACCORDANCE WITH ACI 318-14 (STRUCTURAL CONCRETE) ACI 530-16 (MASONRY STRUCTURES) 4.2. CONCRETE: 4.2.1. 2„ 4Y2 CONCRETE TYPE MIN. 28 DAY DESIGN (fc) MODULES OF ELASTICITY DESIGN (E) C-I-P CONCRETE (NORMAL WEIGHT) 2,500 Psi 2,850 Ksi C-1-P CONCRETE (NORMAL WEIGHT) HERNANDO CO. ONLY 3,000 Psi 3,122 Ksi C-I-P GROUT 3,000 Psi 3,122 Ksi 4.2.2. CONCRETE SHALL CONSIST OF 1" MAXIMUM AGGREGATE CONCRETE MIX WITH SLUMP BETWEEN 6" AND 7" AT TIME OF PLACEMENT. SEE SPECIFICATIONS FOR ADDITIONAL CRITERIA. 4.2.3. GROUT SHALL CONSIST OF PEA ROCK (3/8" MAXIMUM AGGREGATE) CONCRETE MIX WITH SLUMP BETWEEN 8" AND 10" AT TIME OF PLACEMENT. SEE SPECIFICATIONS FOR ADDITIONAL CRITERIA. 4.2.4. CONSTRUCTION JOINTS WILL BE PERMITTED 4.2.5. METHOD OF CONCRETE FORMING, PLACEMENT AND CURING SHALL BE CONDUCTED IN ACCORDANCE WITH THE SPECIFICATIONS AS STATED. 4.2.6. EARTH SUPPORTED SLABS (EXCLUDING EXTERIOR WALKWAYS & DRIVEWAYS) : 31/2" MIN. THICKNESS W/ MIN. REINFORCEMENT OF 6.0 x 6.0 W/ 1.4 x 1.4 WWF @ MID -DEPTH OF SLAB. FIBER MESH PER DESIGN MIX MAY BE USED I.L.O. WWF @ CONTRACTORS DISCRETION. 4.3. CONCRETE MASONRY: 4. 3. 1. FILLED CELLS W/ (1) #5 BAR SHALL BE LOCATED PER PLAN. 4,3.2. LOAD BEARING CONCRETE MASONRY BLOCK SHALL BE ASTM C90-14, TYPE II NON -MOISTURE CONTROLLED. 4. 3. 3. ALL CELLS & CAVITIES BELOW GRADE WILL BE FILLED W/ CONCRETE IN ALL STEM WALLS. 4.3.4. THE AGGREGATE STRENGTH OF THE BLOCK AND MORTAR SHALL BE F'm = 2,000 PSI MINIMUM. 4.3.5. METHOD OF CONCRETE MASONRY PLACEMENT AND CONSTRUCTION SHALL BE CONDUCTED IN ACCORDANCE WITH THE SPECIFICATIONS AS STATED. 4.3.6. MORTAR SHALL BE ASTM C270 TYPE "S" FOR ALL MASONRY CONSTRUCTION. 4.4. STRUCTURAL LUMBER: 4.4. 1.1. INTERIOR LOAD BEARING WALLS SPF #2 ALL EXTERIOR FRAMING SPF #2 4.4. 1.2. ALL FRAME WALLS TO BE CONSTRUCTED USING SPF #2, STUD QUALITY OR BETTER 4.4. 1.2.1 ALL HEADER, BEAMS, COLUMNS ETC. TO BE SYP #2 OR BETTER 4.4.2. ALL PLYWOOD USED FOR EXTERIOR APPLICATIONS SHALL BE APA RATED STRUCTURAL SHEATHING 15/32" EXP 1 OR 7/16" STRUCTURAL 1, U.N.O. 4.4.3. ALL PLYWOOD USED FOR INTERIOR APPLICATIONS SUCH AS SUB FLOORING AND SHEAR WALLS SHALL BE APA RATED SHEATHING EXP 1 U.N.O. 4.4.4. IF OSB BOARD IS TO BE USED IN PLACE OF PLYWOOD IS TO HAVE SIMILAR OR GREATER SECTION PROPERTIES. 4.4.5. ONLY STRUCTURAL LUMBER TO BE USED FOR AN EXTERIOR APPLICATION. WOOD IN CONTACT WITH CONCRETE IS TO RECEIVE A STANDARD GRADE PRESSURE TREATING. 4.4.6. WHEN PRE ENGINEERED TRUSSES ARE CALLED FOR ON THE PLANS THE MANUFACTURER IS TO SUBMIT SHOP DRAWINGS TO THE ENGINEER OF RECORD. 4.4.7. DESIGN, FABRICATE AND ERECT WOOD TRUSSES IN ACCORDANCE WITH THE "DESIGN SPECIFICATION FOR LIGHT METAL PLATE CONNECTED WOOD TRUSSES" BY THE ANSI/TPI 1-2014, BCSI 4.4.8. UNTREATED WOOD SHALL NOT BE IN DIRECT CONTACT WITH CONCRETE. SEAT PLATES SHALL BE PROVIDED AT BEARING LOCATIONS WITHOUT WOODEN TOP PLATES. 4.4.9. ALL EXTERIOR FRAME WALLS SHALL BE STUCCO FINISH- 7/8" STUCCO FINISH PER ASTM C. 926, APPLY 3 LAYERS W/ TOTAL THICKNESS 7/8" OVER METAL LATH. FIRST 2 LAYERS 3/8" THICK EACH. 3RD LAYER 1/8" THICK 4.4.10. INSTALLATION OF EXTERIOR LATHING & FRAMING SHALL COMPLY TO ASTM C 1063 PER FLORIDA CODE R703.7 4.5. FASTENERS AND TIE DOWNS: 4. 5. 1. FASTENERS AND TIE DOWNS SHALL CONSIST OF BUT ARE NOT LIMITED TO: SHAPES, ANGLES, CHANNELS: ASTM A36136M 05 Fy = 36 Ksi ROUND METAL PIPE: ASTM A53, GRADE B Fy = 35 Ksi SQUARE METAL TUBING: ASTM A500, GRADE B Fy = 46Ksi HIGH STRENGTH BOLTS: ASTM A325 MACHINE BOLTS: GALVANIZED ASTM A307 4.5.2. SHEET METAL ACCESSORIES SHALL CONFORM TO: Fy = 33KsiWITH G90 GALVANIZED COATING IN ACCORDANCE WITH ASTM A525-87. 4. 5. 3. NAILS SHALL CONSIST OF: COMMON WIRE NAILS WITH MINIMUM DIAMETER AS FOLLOWS: 8d = 0.131", 10d = 0.148", 12d = 0.148", 16d = 0.162". 4.5.4, ALL FASTENERS AND TIE DOWNS EMBEDDED IN CONCRETE OR USED IN AN EXTERIOR APPLICATION ARE TO RECEIVE AN ANTI -CORROSIVE COATING BY MANUFACTURER PRIOR TO INSTALLATION, 4. 5. 5. ALL FASTENERS AND TIE DOWNS ARE TO PROVIDE THE UPLIFT CAPACITY CALLED FOR IN THE PLANS ARE A MINIMUM. 4. 5. 6. ALL FASTENER TIE DOWNS, BEAM HANGERS, JOIST HANGERS, AND FLOOR TRUSS STRAPPING ARE TO BE INSTALLED IN ACCORDANCE WITH THE PLANS AND SPECIFICATIONS. 4.5.7. CONCRETE EMBEDDED'X BOLTS USED FOR UPLIFT ARE TO BE WET SET PRIOR TO INITIAL SET OF THE CONCRETE, SPACING AND ALIGNMENT ARE TO BE IN ACCORDANCE WITH THE DESIGN PLANS, U.N.O. ALTERNATES TO "J" BOLTS ARE NOTED ON PLANS. 4. 5. 8. CONCRETE EMBEDDED TIE DOWNS USED FOR TRUSS AND WALL UPLIFT ARE TO BE PLACED AROUND EMBEDDED REINFORCING PRIOR TO OR WHILE PLACING GROUT. 4.6. MICRO -LAM LUMBER: 4.6.1. MICRO -LAM STRESS GRADES SHALL PROVIDE THE FOLLOWING MINIMUM PROPERTIES: E = 2,000,000 PSI Fb = 2,950 PSI Ft = 1,850 PSI Fc = 500 PSI (PERPENDICULAR) Fc = 2,700 (PARALLEL) 4.7. STEEL: Fv= 285PSI 4.7.1. INSTALLATION OF ALL STEEL TO BE PERFORMED BY AN EXPERIENCED, QUALIFIED STEEL ERECTOR. 4.7.2. FABRICATE AND ERECT ALL STRUCTURAL STEEL IN ACCORDANCE WITH A.I.S.C. "SPECIFICATION FOR THE DESIGN, FABRICATION, AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS". 4.7.3. STRUCTURAL STEEL: ASTM A36/36M 05. 4.7.4. STEEL TUBING: ASTM A500, GRADE B. 4.7.5. WELDED CONNECTIONS: E70XX ELECTRODES, MINIMUM SIZE FILLET WELDS 3/16", AWS CERTIFIED WELDERS. CERTIFICATION PAPERS TO BE SUBMITTED UPON REQUEST. 4.7.6. WHERE STEEL BEAMS ARE CONTINUOUS OVER COLUMNS, PROVIDE WEB STIFFENER PLATES ON EACH SIDE OF THE WEB, OF A THICKNESS EQUAL TO BEAM FLANGE THICKNESS, LOCATED AT THE CENTER LINE OF THE TUBE COLUMN. 4.7.7. THE STEEL FRAME IS "NON -SELF SUPPORTING". ADEQUATE TEMPORARY SUPPORT SHALL BE PROVIDED BY THE CONTRACTOR UNTIL REQUIRED CONNECTIONS OR 4.8. SOIL: ELEMENTS ARE IN PLACE. 4. 8. 1. MINIMUM SOIL BEARING PRESSURE CAPACITY OF 2,000 PSF, FOUNDATIONS HAVE BEEN DESIGNED WITH THE MIN. CAPACITY OF 2,000 PSF 4.8.2. ALL SOIL IS TO BE CLEAN & POISONED FOR TERMITES PER FLORIDA BUILDING CODE 7TH EDITION (2020) RESIDENTIAL SECTION R318. 4.8.3. SOIL IS TO BE COMPACTED TO 95% MODIFIED PROCTOR AS DEFINED BY ASTM D 1557-02E01 TERMITE PROTECTION - CONTRACTOR TO USE (1) OF THE TREATMENTS BELOW Borate / Boracore treated lumber Soil Chemical Barrier Method Other treatment - Must specify proposed method and submit documentation, which substantiates the proposed method, is an approved termite protection system or method. OR CHEMICAL SOIL TERMITE TREATMENT IS USED 1. FBC-R R318.1-"A permanent sign which identifies the termite treatment provider and need for re -inspection and treatment contract renewal shall be provided. The sign shall be posted near the water heater or electric panel" 2. Condensate and roof downspouts shall discharge at least V-0" away from the building side walls. 3. Irrigation/sprinkler systems including all risers and spray heads shall not be installed within V-0" of the building side wall. 4. FBC-R R318.7- To provide for inspection for termite infestation, between wall covering and final earth grade shall not be less than 6 inches. Exception: Paint or decorative cementitious finish less than 5/8" thick adhered directly to the foundation wall. 5. FBC-R R318.1.1 - Initial treatment shall be done after all excavation and backfill is complete. 6. FBC-R R318.1.2 - Soil disturbed after the initial treatment shall be retreated including spaces boxed or formed. 7. FBC-R R318.1.3 - Boxed areas in concrete floors for subsequent installation of traps, etc., shall be made with permanent metal or plastic forms. Permanent forms must be of a size and depth that will eliminate the disturbance of soil after the initial treatment. 8. FBC-R R318.1.4 - Minimum 6 mil vapor retarder must be installed to protect against rainfall dilutipn. If rainfall occurs before vapor retarder placement, retreatment Is require 9. FBC-R R318.1.5 - Concrete overpour and mortar along the foundation perimeter must be removed be ore exterior soil treatment. 10. FBC-R R318.1.6 - Soil treatment must be applied under all exterior concrete or grade within V-0" of the structure sideways. 11. FBC-R R318,1.6 - An exterior vertical chemical barrier must be installed after construction Is complete, including landscaping and Irrigation. Any soil disturbed after the vertical barrier is applied, shall be retreated, 12, FBC-R R318.1 - All buildings are required to have pre -construction treatment. 13. FBC-R R318.1 - A certificate of compliance must be issued to the building department by a licensed pest control company before a certificate of occupancy will be issued. The certificate of compliance shall state: "The building has received a complete treatment for the prevention of subterranean termites. The treatment is in accordance with the rules and laws of the Florida Department of Agriculture and Consumer Services". 14. FBC-R R318.6 - After all work is completed, loose wood and fill must be removed from below and within V-0" of the building. This includes all grade stakes, tub trap boxes, forms, shoring or other cellulose containing material. NOTE: IT IS THE CONTRACTORS RESPONSIBILITY TO REVIEW ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. FLORIDA DESIGN SOLUTIONS, INC. IS RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF THIS PROJECT ONLY. ANY DISCREPANCY BETWEEN FIELD CONDITIONS, OTHER DESIGN PROFESSIONALS' SHOP DRAWINGS, CONTRACTORS' BUILDING METHODS, AND THESE SIGNED AND SEALED DRAWINGS MUST BE BROUGHT TO THE ATTENTION OF FLORIDA DESIGN SOLUTIONS, INC. PRIOR TO THE COMMENCEMENT OF CONSTRUCTION. NOTE: GYPSUM BOARD MAY BE INSTALLED USING GWB54 NAILS TO SET IN PLACE. FIELD FASTENING SHOULD BE TYPE "W" 1 4" DRYWALL SCREWS AT 12" O.C. FOR CEILINGS AND 1%8' DRYWALL SCREWS AT 12" O.C. FOR WALLS. ALL ENDS AND EDGES OF WALLBOARD SHALL OCCUR OVER AND BE SCREWED TO SUPPORTS. MAXIMUM SCREW SPACING AT ENDS (EDGES IN VERTICAL APPLICATION) SHALL BE 6" O.C. AT EACH SUPPORT. MINIMUM SCREW / NAIL DISTANCE FROM EDGE SHALL BE /". THIS SHALL APPLY TO BOTH CEILING AND WALL INSTALLATION. DRYWALL SHIMS SHALL BE USED ONLY WHERE NECESSARY. OPENINGS CUT FOR OUTLETS, SWITCHES, ETC, SHALL BE OF A TOLERANCE THAT CAN BE COVERED ADEQUATELY WITH NORMAL SWITCH PLATES AND COVERS WITHOUT ADDITIONAL TAPING OR CAULKING. DRYWALL SHALL NOT BE INSTALLED WITHOUT PROPER BACKING. NOTE: ALL HEADERS BEAMS ETC ARE TO BE SYP #2 OR BETTER AND OR MICROLAM AS INDICATED ON THE DRAWINGS AND CAN NOT BE REVISED. Q 0 r a) •5 � W ga0o cc sow 0 LLL DX 5 M r� tJ u a) � N 0 s cd Q ra � a) a) L) G r r rZ­Q. To the best of the Engineer's knowledge, information and belief, the structural plans and specifications contained within these drawings comply with the 2020 Florida Building Code - Residential 7th Edition. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. W 'a' EE 8 NN O N N �Np ik Lo 0 LL 0) �cNj0 LL ni a' d Q a JLLLL Z z Zm cm o = m v 0 0 y _W ' c o :3C 0��� z W J 00 Z N Cl)Z IL rn 1=- .. 0 �' 00 7r-1❑ Z W M N � MKAI zM � N M c m z N z 0 o LLL 4-1 n (� w m O w s U w m !- J E m I �Q ° U o U) c Q o _ w M J ¢ � � Z Z i Z. g O >� Z< a 0 E U oLL Wo ze ❑a tv F- d _ �0 UO ZEE, co ra < = &a w z C Z 3 U am m0 ox Z m a'w o c� a LL a a Z W m <o aZ G i3 0 w <a ) � a M zle 0 � h O L0 rn Q 0 CL ^�^,, i 00 Co O T G O J Y T � Y T QI O N o O N LO Q O T E M r_ 00 � o Z Z E T c c ii 0 _j ¢ o JOB NO: 22-04746 SCALE : AS NOTED SHEET NO. SN I IA I I I I I I I 3 3 a LO 2 _ V) O 0 J r 0 I 3 =I Q LO 0 _ O .o 0 0 J 0 I N U un v to 0 C 0 3 a 0 0 o_ 0 J Y U 0 i c 0 0 J 2 LZ N N Ji 0 0 a N N n 0 c 0 U z W m > v N THIS DETAIL ONLY REFERS TO THE DIAMOND -MESH EXPANDED METAL LATH ATTACHMENT. METAL LATH WALL SHEATHING 16GAx1-1\2" LONG (3/4"-1" CROWN) 11f MAX kf I. I 16GAx1-1/2" LONG (3/4%1" STAPLES @ 6" O.C. VERT BETWEEN STUDS (NOTED THUS:-) - OFFSET CROWN) STAPLES @ 6" STAPLES BETWEEN STUDS AS SHOWN V O.C. VERT INTO STUDS (NOTED THUS:-) METAL LATH ATTACHMENT DETAIL REV. 09.24.21 SCALE: 3/4" = V-0" *DETAIL EXCEEDS THE REQUIREMENTS FOR FBCR 703.7.1 LATH* CORNER OF HOME GARAGE SIDE 10'-0" TANK -LESS W/H H C G O O O 5'-0" Q01 - STUB -OUT FOR 1'-0" o o GAS METER O ° d- U ~O (V = • MEASUREMENTS ARE FROM FINISHED FLOOR • ROUGH -IN GAS TO RIGHT (ALWAYS) - 12" OFF -CENTER • ROUGH -IN ELECTRIC TO LEFT (ALWAYS) - 12" OFF -CENTER GAS CONNECTION DETAIL **ONLY APPLIES TO HILLSBOROUGH AND PASCO COUNTY" RAFTER SPAN TABLE MEMBER SIZE AND SPACING MAXIMUM LENGTH MEMBER CONNECTIONS* 2" X 4" @ 16" O.C. 7-5" (2)16d TOENAILS 2" X 6" @ 16" O.C. 10'-8" (2)16d TOENAILS 2" X 8" @ 16" O.C. 13'-9" (3)16d TOENAILS 2" X 10" @ 16" O.C. 16'-5" (1) SIMPSON HTS20 OR (3) 16d TOENAILS 2" X 12" @ 16" O.C. 19'-3" (1) SIMPSON HTS20 OR (4) 16d TOENAILS 2" X 4" @ 24" O.C. 6'-1" (2)16d TOENAILS 2" X 6" @ 24" O.C. 8'-6" (2)16d TOENAILS 2" X 8" @ 24" O.C. 11'-0" (2)16d TOENAILS 2" X 10" @ 24" O.C. 13'-0" (3)16d TOENAILS 2" X 12" @ 24" O.C. 15'-4" (1) SIMPSON HTS20 OR (3)16d TOENAILS * TOENAIL CONNECTIONS DESIGNED FOR SHEAR ONLY (i.e. RAFTER TO RIDGEBEAM). ** SOUTHERN YELLOW PINE, 55 PSF LOADING Backer and Filler Block Dimensions BCI®Joist Backer Block Thickness Filler Block Thickness Series 3/4" or 7/8" 5000s 1.8/1.7 wood panels Two 3/4" wood panels or 2 x 1-1/8" or two 1/2" 6000s 1.8/1.7 wood panels 2 x _ + 5/8" or 3/4" wood panel 1-1/8" or two 1/2" 6500s 1.8/1.7 wood panels 2 x _ + 5/8" or 3/4" wood panel 1-1/8" or two 1/2" 602.0 wood panels 2 x _ + 5/8" or 3/4" wood panel 902.0 2 x — lumber Double 2 x _ lumber DOUBLE JOIST CONSTRUCTION (Not required if both loaded equally from above) Filler blocking 1/8" gap FILL CELL STD. 900 HOOK BOND BEAM 11 a STD. 90° CONT. #5 BOR T. #5 I HOOK Ir-7—�� BAR i CONT. 20M )UNDATION HIGHEST )ND BEAM 0VI1V L)E- MIVI %D 1 CI- SCALE: N.T.S. 2nd FLOOR INTERIOR/EXT WALL SEE PLAN FOR MORE INFO -CONT. BASE PLATE BEARING COLUMN SEE PLAN FOR REQ'D PLYWOOD FLOOR COLUMN AND SHEATHING PER PLAN CONNECTIONTJI TO BE CUT TO ALLOW FOR BLOCKING/TJI \�—MASONRY WALL OR \� \ INTERIOR BRG. WALL TJI PER PLAN \� OTHERWISE SOLID BLOCKING TO MATCH # OF 2nd FLOOR Solid block all posts from STUDS above to bearing below. SECTION @ INT. BRG. WALL N.T.S. x } g p min. i / ' min. 2 max. - - Web Stiffener Fastener Schedule i 2" max.- ma I 4 i Joist Beariri�Location T - Series Depth End Intermediate_ ®_9 1/2112-8d 2-8d _ BCI5000s 117/8' 2-8d 3-8d Clinch nails -1 ✓ 1------�_' 2-8�- when ®I 9 1/2" 2-8d 2-8d BCI 6000s 111-7/8 2-8d _ 3-8d possible BCI 6500s®' _ 14" 2-8d 5-8d �. 16" 2-8d 6 8d - 1 Support back of web during nailing to prevent damage to PP 9 9 P 9 T 11 7/8 24d 3-8d web -flange connection. �'�ti \ -- BCI 60s� 14" 2-8� 5-8d 2) Block solid between joists for full length of span. Tight fit g - 16 2 8d 6 8d 3) Leave 1/8" gap between top of filler blocking and bottom of top flange. 11 7/8" 3-16d 3-16d 4 Place joists together and nail from each side with 2 rows of 10d nails 1 g 2x4/Plywood/OSB web stiffener 2" min. BCI 90s® 14" _ 4" max 5 1 td 5-1.6d required when Indicated or 16 6-16d 6-16d 2x_: CONTRACTOR TO PROVIDE 2x TO FILL THE HEIGHT at 12" o.c., clinched when possible. Stagger rows from opposite -- - - OF THE JOIST ASA REQUIRED LEAVING Y" GAP @ TOP sides by 6". - Hangers with side nailing. -Hangers with sides not containing WEB STIFFENER DOUBLE JOIST CONNECTION topflange ofctst. - Birdsmouthuth cuts. N.T.S. N.T.S. - Under 2nd floor column w/ loads hi her than 15001b SQUASH BLOCKS AT INTERIOR BEARING Vertical load transfer =1900 plf max along load bearing wall. Load bearing wall must stack *Non -stacking walls over squash=20 blocks and require additional wall or beam below.* consideration. Check local building -S 1/16 code for appropriate details in One 10d box areas=20 of high or-20 sinker lateral load. nail each side at bearing. Squash block (2x4 minimum) Bearing wall, Versa -Lam LVL or Glulam Beam NO HOLES (EXCEPT KNOCKOUTS) ALLOWED IN BEARING ZONES -� DO NOT cut, notch or drill flanges i for each lapped joist. V 10dnails SECTION @ INT. BRG. WALL N.T.S. Boise Joist Blocking Use 3" (10d) nails at 6" o.c. MINIMUM SPACING = 2x GREATEST D DIMENSION OF LARGEST HOLE (see table below) (KNOCKOUT EXEMPTS) D (see table below) g BLOCKING PANEL, INTERIOR Vertical load transfer =1900 plf max. along bearing wall Required on interior walls : - for vertical load transfer Plumbing when load bearing - for lateral support when joists meet over wall, or wall stacks directly over wall or beam below Load bearing wall must stack over blocking and wall or beam below.* Joist When joists meet over wall, provide 1 3/4" minimum bearing for each. I -Joist can be offset up to 3" to avoid vertical plumbing 3" max JOISTS OFFSET Use lUdx3" nails at 6"o.c. for all joist blocking panel *Non -stacking walls require additional consideration.— A 1Y" ROUND HOLE MAY DO NOT CUT HOLES 6' BE CUT ANYWHERE IN 6 6 CANTILEVER LARGER THAN 1Y2' THE WEB. PROVIDE AT ROUND IN LEAST 3" OF CLEARANCE CANTILEVERS. FROM OTHER HOLES MINIMUM DISTANCE FROM SUPPORT, LISTED BELOW, IS REQUIRED FOR ALL HOLED GREATER THAN 1)/2" Round Hole 04ameter (4n) 2 3 4 5 16 7 8 8.875 10 11 12 13 `le S". ectan ,ler lde'n) 2 3 5 6 8 9: 10 Any 16" joist Span (ft) 8 V-0" V-1" l'-2" V-2" V-3" V-3" V-7" 1'-11" 2'4" 2'-9" 3'-2" 3'-7" 12 V-0" V-1" V-2" V-2" V-3" V-9" 2'4" 2'-11" 3'-7" 4'-2" 4'-9" 5'4" 16 V-0" 1'-l" V-2" V-2" V-7" 2'-5" X-2" 3'-10" 4'-9" 5'-7" 6'4" 7'-2" 20 1 1'-0" 1'-1" 1'-2" 1'-2" 2'-0" 1 X-0" 4'-0" 4'-10" 5'-11" 6'-11" 7'-11" 8'-11" 24 V-0" 1' 1" V-2" V-3" 2'-5" 3'-7" 4'-9" 5'-10" 7'-2" 8'-4" 9' 6" 10'-9" ICON*] 1. JOISTS MUST BE PROPERLY DESIGNED TO MEET BUILDING CODE REQUIREMENTS. 2. TABLE IS FOR UNIFORMLY LOADED MAXIMUM LOADS OF 40 PSL(LIVE) AND 15 PSF (DEAD) ON SIMPLE SPAN APPLICATIONS ONLY. 3. REFER TO JOIST SPECIFIER GUIDE FOR INSTALLATION AND OTHER INFO. 4. SELECT A TABLE ROW BASED ON JOIST DEPTH AND THE ACTUAL JOIST SPAN ROUNDED UP TO THE NEAREST TABLE SPAN. SCAN ACROSS THE ROW TO THE COLUMN HEADED BY THE APPROPRIATE ROUND HOLE DIAMETER OR RECTANGULAR HOLE SIDE. USE THE LONGEST SIDE OF A RECTANGULAR HOLE. THE TABLE VALUES IS THE CLOSEST THAT THE CENTERLINE OF THE NEAREST SUPPORT. 5. THE ENTIRE WEB MAY BE CUT OUT. DO NOT CUT THE FLANGES. HOLES APPLY TO EITHER SINGLE OR MULTIPLE JOISTS IN REPETITIVE MEMBER CONDITIONS. 6. FOR MULTIPLE HOLES, THE AMOUNT OF UNCUT WEB BETWEEN HOLES MUST EQUAL AT LEAST TWICE THE DIAMETER (OR LONGEST SIDE) OF THE LARGEST HOLE. 7. 1Y" ROUND KNOCKOUTS IN THE WEB MAY BE REMOVED BY USING A SHORT PIECE OF METAL PIPE AND HAMMER. 8. HOLES MAY BE POSITIONED VERTICALLY ANYWHERE IN THE WEB. THE JOIST MAY BE SET WITH THE 1Y2" KNOCKOUT HOLES TURNED WITHER UP OR DOWN. 9. THIS TABLE WAS DESIGNED TO APPLY TO THE DESIGN TO APPLY TO THE DESIGN CONDITIONS COVERED BY TABLES ELSEWHERE IN HIS PUBLICATION. USE THE BC CALC SOFTWARE TO CHECK OTHER HOLE SIZES OR HOLES UNDER OTHER DESIGN CONDITIONS, IT MAY BE POSSIBLE TO EXCEED THE LIMITATIONS OF THIS TABLE BY ANALYZING A SPECIFIC APPLICATION WITH THE BC CALC SOFTWARE. HOLE CUTTING CHART N.T.S. N.T.S SIMPSC w/(22) NAILS I 5/8" 0 THRU BOLT SIMPSC w/ (22) NAILS I R TRUSS OP PLATE I.0 TYPICAL SIMPSON MGT TO BUILT-UP COLUMN DETAIL TYPICAL SIMPSON LUS/HUS/HUC INSTALLATION AIN. EMBEDMENT SCHEDULE FOR AND QUANTITY )F FASTENERS TYPICAL SIMPSON META12 / META12 TSS INSTALLATION A/C CHASE 4" PVC SLEEVE THRU STEM WALL Backer block (12" wide min.) -1 I I —III —III —I — Nail with 10- 10d nails. —1 I 1=1 I 1=1 I 1=1 11= —i I I = — Install tight to top flange. SLEEVE THRU STEM SEE PLAN FOR •• • ; . • ° Joist hanger - i ��_ a. � A FOUNDATION INFO � � �� a . STEM FOUNDATION \\ \ r GRADE REINF. SEE PLAN Filler block. Nail with \� 10-10d nails. d Backer block required where top a —'X 4 4� mount hanger load exceeds 250 lbs. _ Install tight to top flange. I—III-1 1= I —I I— I I ,r 1/4"-2" gap-.� 11-1 I I —I • a ° _ I_ l -I Backer Block //� A/C CHASE 4" PVC (2) #5 REBAR "Top Mount" "Face Mount" SLEEVE THRU FOOTING Backer block shall be tight Backer block shall be tight MONO FOUNDATION to bottom of top flange with to top of bottom flange with 1/4%2" gap at top of bottom 1/4"-2" gap at bottom of top flange. flange. Web stiffner as Web stiffeners are not required when top required if hanger flange is laterally supported by joist hanger. doesn't meet height TYP. FND. PENETRATIONS requirements i % ° ✓! -0.6 X Joist SCALE: N.T.S. ` o ✓ � � % depth ✓ I -JOISTS BUCKETS N.T.S. SIMPSON META12 / META12 TSS INSTALLATION @ MID SPAN NOTE: UPLIFT VALUE IS BASED ON S.P.F. •�® LOCATION OF SECOND H10A SIMPSON H10A ° ° (WHEN wJ (18) 10d x 1 1/2" ° REQUIRED) NAILS UPLIFT = 1015# TYPICAL SIMPSON H10A INSTALLATION TYPICAL SIMPSON MTS / HTS INSTALLATION TOP (2) #5's x 4'-0" CENTERED @ PIPE PENETRATION PLUMBING LINE PVC OR SCH40 SLEEVE 12" BELOW PIPE VERTICAL THRU FND. GRADE TOP (2) #5's x 4' 0"—\ CENTERED @ PIPE PENETRATION PVC OR SCH40 SLEEVE PLUMBING LINE \4 A SEE FND. PLN. SIZE & REINF. In PIPE PERPENDICULAR TO FND. TOP (2) #5's x 4'-0" PVC OR SCH40 SLEEVE CENTERED @ PIPE PENETRATION PLUMBING LINE d ° ° d d ° ° dv G :I d 4 O d d a SEE FND. PLN. SIZE & REINF. c C- 3 - o W N Cif ° ClQ CQ1 cc pp c� +� c�U N LLa J� Cq C:N ® O L n M F_ o � a � o `t?s, To the best of the Engineers knowledge, information and belief, the structural plans and specifications contained within these drawings comply with the 2020 Florida Building Code - Residential 7th Edition. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. tll FW- o f pp �n N .4 a N 8 R W v V «_. m C 7�� w M tANo LL a w z LL a � z Z m rn ° O _ °o 1 M ° W U) CP w �z m co F N U O O C) ❑❑❑ W Z N f7 o G � J d QE3 N N N z 0 Q� C� o 2 w m V Ow g N C N �( y rn �A�.��..,� �— U W J — $ t U o ° w M CO J y ¢ O S5 Z Q N z E C)z O� o ro a` o o 0< Cc>z ro wg �J s �ru =am0 ro Zac m v m z Z 3 S Z a° W T 3 O wLL aw � �w M � ZIQ d I O 0O � L LO I� L 00 ca O Ir— :3 O J Y T C Y f CD m m QI O N o O N � 0) LO T Q CO T M � 00 i o z Z E 1— in m C a U 'a p JOB NO : 22-04746 SCALE : AS NOTED SHEET NO. SN 1 Y v 3 I o: a v N 0 00 0 0 I a �r rn L0 En 00 0 0 J N L0 L0 0 3 a i 0 v c C J U i C 0 0 N N 0 0 a N N CD 0 0 O 3 U Z m ROOF FLASHING AND ROOF FLASHING COMPONENTS TO BE IN ACCORDANCE w/ R903.2, FLORIDA BUILDING CODE 7TH EDITION (2020) RESIDENTIAL 12 (TYP•) VARIES �T 5/8" OR 1/2" HIGH-� STRENGTH CEILING BOARD PER CODE (OR 5/8" GYP. TYPE "X" @ GARAGE W/A HABITABLE ROOM ABOVE) W/DRYWALL SCREWS @ 7" O.C. CEILING & 8" O.C. WALLS I INSULATION PER -� CHART ON FLOOR PLAN 1x2 P.T. HORIZONTAL NAILER STD. 90-HOOK (SEE DETAIL 2x BLOCKING HORIZONTALLY@ 2x #2 SPF STUDS INTERVALS NOT EXCEEDING @16" O.C. W/ (2) 1 U-0" (R302.11) 16d TOENAILS T & B FOR UNDERLAYMENT REQUIREMENTS SEE R905.1.1 1/2" GYP. WB (MIN.) @ GARAGE SIDE IF z PRE ENGINEERED WOOD APPLICABLE. TRUSS @ 24" O.C. U.N.O. 2x P.T. PLATE 1/4" DIA. X 31/4" TAPCONS @ 24" O/C & HURRICANE ANCHOR @ EACH @ 6" MAX FROM END OF 2 x PLATE -E TRUSS (SEE UPLIFT SCHED.) W/ (2) #5 CONT. ON 3" 6 x 6 W1.4 x W1.4 METAL PL. UNDER EA. TRUSS CHAIRS (TYP.) WWF OR FIBERMESH MOISTURE BARRIER o ° e . SHINGLE ROOF, SHINGLES TO BE IN ACCORDANCE w/ ASTM - I D I T D7158-CLASS G or H, or ASTM - , • I - D3161-CLASS F, IN = - __ ° - ACCORDANCE w/ TABLE R905.2.6.1, FLORIDA BUILDING _- CODE 7TH EDITION (2020) 8„T)jTF= I I r RESIDENTIAL ROOF SHEATHING - SEE SCHEDULE - [RSH] - ON TYPICAL INTERIOR BEARING FRAMING SHEET FOR SHEATHING AND FASTENERS WALL w/ OUT UPLIFT rG G ELEV. VARIES SEE TYP. WALL SECTION SCALE: 3/4"=1'-0" S3 -ALUMINUM DRIP EDGE ALUMINUM FASCIA •2x SUB FASCIA -SEE STRUCTURAL SOFFIT SHEET SS 8"x8"X16" KNOCK -OUT BLOCK W/ 1#5 CONT. FILLED SOLID W/GROUT -8" C.M.U. TYPICAL TYPE "S" MORTAR -ARCHITECTURAL FINISH 1x2 PT WD FURRING @ 24" O.C. 1/2" GYPSUM WALLBOARD U.N.O. (1) #5 VERT. IN FILL CELLS (SEE FOUNDATION PLAN FOR LOCATIONS) 1x4 P.T. BASE NAILER 4"x4" INSPECTION 31/4" BASEBOARD PORT AT EACH FILLED CELL TYPICAL MIN. 2500 PSI CONC. SLAB M AT GARAGE CONTRACTOR MIN PSI MAY VARY PER coTO CUT BLOCK OR POUR MUNICIPALITY. CURB DUE TO SLOPE CONCRETE SLAB W/ 6X6 NOTE:EXTEND W1.4XW1.4 WWF OR - DECO FINISH 4" to 6" "FIBERMESH" BELOW GRADE o 6 MIL VAPOR —I I �' 11 BARRIER ; D 4 COMP. SOIL. (COMPACTED TO 95°lo T TI I MODIFIED PROCTOR I I I TI I I I ASTM D1557) 3" MIN. CLR. (2) #5 REBAR CONT. 1'-4" (1 STORY ON 3" CHAIRS TYP. ) STD. 90 HOOK (SEE U.N.O. 4" 1'-8" (2 STORY) DETAIL) TYPICAL WALL SECTION rA SCALE: 3/4" = V-0" S3 OPT: DEPRESS SLAB 5Y" DEEP AND 6" BEYOND DOOR TO RECEIVE BLOCK WALL BEYOND PAVERS / DRIVEWAY CONCRETE SLAB -A iy � 14" PAVERS -11O.H.D. RECESS *T z r. 4 00 SEE A/S3 OR J/S6 �ILI I I I I,I 1 II I �' FOR REINF. INFO. 3" MIN. CLEARANCE 1' " (1 STORY) / V-8" (1 STORY w/ DEPRESSED SLAB OPT.) 1' 8" (2 STORY) GARAGE DOOR SLAB RECESS J.1 SEE TYP. WALL SECTION FOR SCALE: N.T.S. S3 ADDITIONAL INFORMATION. LOAD BEARING OR EXTERIOR WALL SEE CC/S3 OR G/S3 FOR ANCHOR BOLT INFO. (IF NO UP LIFT ON WALL SEE GG/S3) *SIMPSON SP1 w/ (10)10d NAILS TYP. MONO OR STEMWALL- FOOTING MONO SHOWN FOR CLARITY NOTE: , *FOR BEARING WALL W/ UPLIFT ONLY 8"x8"x16" NOMINAL BLOCK WITH 3/8" MORTAR BETWEEN COURSES GARAGE SLAB AT STEP SCALE: 3/4"=1'-0" 1/2" OR 7/16" OSB MIN. PLYWOOD SHEATHING - NAILED W/ 8d COMMON NAILS @ 4" O/C 2x S.P.F. STUDS @ 16" O.C. BOUNDARIES, 6" O/C EDGES, AND 12" O/C FIELD. 2x STUD SHEAR WALL REQUIRES 2x BLOCKING @ SEAMS. 8" C.M.U. 1"x P.T. STUD 2x BLOCKING HORIZONTALLY@ INTERVALS NOT EXCEEDING N #5 VERT. IN FILLED CELL 10'4" (R302.11) 5/8"x6" "J" BOLTS BOLT 5/8- x 10" "J" BOLT @ 24" O/C W/ 2"°X 3/16" @ 24" O.C. VERT. OR PLATE WASHER TYPICAL 5/8" x 6" EPDXY BOLT OR MIN, 2500 PSI CONCRETE SLAB W/ (6) 1/4"x3 1/4" TAPCONS 6 x 6 W1.4 x W1.4 WWF OR SPACED EVENLY FIBERMESH 2x P.T. PLATE ASSUMED FINISHED E FRAME WALL TO C.M.U. WALL CONNECTION 5/8"OR 1/2" HIGH STRENGTH ---- (U.N.O.) (OR %" GYP. TYPE "X" @ GARAGE W/A HABITABLE ROOM ABOVE) S.P.F. DOUBLE TOP PLATE SIMPSON SP2 w/ (12)10d NAILS 1/2" CDX PLYWOOD OR 7/16" O.S.B. SHEATHING REQ'D. FOR ALL EXTERIOR OR SHEAR WALLS AS INDICATED ON THE PLAN, ATTACH SHEATHING W/ 8d COMMON NAILS @ 3/8" MORTAR BETWEEN 4" O.C. @ BOUNDARIES, 6" O.C. @ SLAB & BLOCK EDGES, AND @ 12" O.C. @ FIELD 5/8"° x 10" "J" BOLT @ 24" 0 ' C 'W/ 2"°x3/16" PLATE WASHER (TYP.) ELEV. 0-0 (ALT: 1/2 x12 TITEN HD @ 24 O.C. OR 5/8"x10' WEDGE ANCHOR A.F.F. @ 24" O.C.) 2". ELEV. 4-31/2" z 31/2" MIN. A.F.F. o D' Nco D — — ° -TRUSS BOTTOM CHORD OR 2x4 #2 SPF 5/8"OR 1/2" HIGH STRENGTH BLOCKING @ 12" O.C. w/ (2)12d TOE NAILS (U.N.O.) (OR %" GYP. TYPE "X" @ EACH END (WHEN PARALLEL) GARAGE W/A HABITABLE ROOM _ -SEE UPLIFT SCHEDULE FOR UPLIFT ABOVE) CONNECTIONS. _ S.P.F. DOUBLE TOP PLATE 2"x S.P.F. (OR EQUAL) STUDS @ 16" O.C. U.N.O. SIMPSON SP2 w/ (12)10d NAILS 2x BLOCKING HORIZONTALLY@ INTERVALS 5/8"° x 10" "J" BOLT @ 24" O.C. w/ - NOT EXCEEDING 10'-0" (R302.11) 2" 0/16" PLATE WASHER (TYP.) - (ALT: 1/2"xl2" TITEN HD @ 24" -INSULATION PER CHART ON FLOOR PLAN O.C. OR 5/8"x10' WEDGE ANCHOR @ 24" O.C.) SIMPSON SP1 / 10 10d NAILS "SIMILAR AT FOUNDATION ONLY" TRUSS BOTTOM CHORD OR 2x4 #2 SPF BLOCKING @ 12" O.C. w/ (2) 12d TOE NAILS EACH END (WHEN PARALLEL) SEE UPLIFT SCHEDULE FOR UPLIFT CONNECTIONS. 2"x S.P.F. (OR EQUAL) STUDS @ 16" O.C. U.N.O. -2x BLOCKING HORIZONTALLY@ INTERVALS NOT EXCEEDING 10'-0" (R302.11) -INSULATION PER CHART ON FLOOR PLAN w ( ) IF NOTED, THIS REFERS TO THE-SIMPSON SP1 w/ (10) 10d NAILS STEP, SIZE OF FOUNDATION AND •2x P.T. BOTTOM PLATE REINFORCEMENT AND WILL NOT 2x P.T. BOTTOM PLATE 113 x 6 W1.4 x W1.4 INCLUDE THE WALL / 6 x 6 W1.4 x W1.4 ATTACHMENTS - 2" WWF OR FIBERMESH WWF OR FIBERMESH 3 1 /2"(min.) - 4" = I — 11 III —I I I— T_II I� —_-- I �W11111 (2) #5 4" 1-4" 8" U.N.O. MIN. TYPICAL BEARING WALL STEP SHEARWALL "SHEAR WALL" SCALE: 3/4"=1'-0" 31/2" MIN. - 7 � 1/2"(min.)-4" n P ° 9� _ �r 1/2"(min.)-4" ]) Gor, •(\E� SEGU�� �QGs• M 00 _ _ — 31/2"(m n.) - 4" _�= I - y - �r - -'I� (2) #5 CONT. 4" "- -4}' U.N.O. MIN. rCC TYPICAL BEARING WALL @ STEP 2x STUDS @ 16" O/C M�N�MO �s \ INSULATION PER FBC AND ENERGY FORM SUBMITTED WITH PERMIT APPLICATION 7/8" STUCCO FINISH PER ASTM C. 926 APPLY 3 LAYERS W/ TOTAL THICKNESS 7/8" OVER METAL LATH. FIRST 2 LAYERS 3/8" THICK EACH. CONTINUOUS TO FOOTER BELOW 90 HOOK DETAIL 3RD LAYER 1/8" THICK. @ K.O. BLOCK EMMA SIMPSON SP1 w/ (10)10d NAILS @ EA. STUD 2X PT PLATE 20" MIN. LAP [24" MIN. LAP) #5 REINFORCING WEEP SCREED INSTALLED BAR PER MFR INSTRUCTIONS #3 OR #4 REINFORCING BAR GRADE �, ' z #3 & #4 LAP SPLICE GRADE 40 MIN. Fy= 40ks1 T A D FINISH GRADE o0 [GRADE 60 MIN. Fy= 60ksi) 25" MIN. LAP [30" MIN. LAP] 7 I _ _ O° 6 MIL VAPOR BARRIER -� o ° I = R 1 7/8" T III —III T #5 REINFORCING BAR -� Z o frm Tff Tff�Tf—Tr- • �Tt l- T #ri I AP SPI IC F e r COMP. SOIL. (COMPACTED TO SEE TYP. WALL SECTION FOR ADDITIONAL SCALE: 3/4"=V-0" QS3 SLAB INFORMATION. 6x6W1.4xW1.4 31/2" WWF OR FIBERMESH min.) 4 ° ° 'v GRADE a 00 — — — — — • (1) #5 REBAR w/ OPT. 1T=1 —I I [= I I— I I-1 11= I I —SCREEN ENCLOSURE MIN. TYPICAL THICKENED SLAB EDGE L SCALE:3/4"=1'-0" S3 BLOCK WALL BEYOND EXPANSION JOINT 13" O.H.D. RECESS fV ' Cn r L a .� I�� I I _ I I—T �60 4„ II •I I I � . � • :.. I —I I h SEE A/S3 0R J/S6 -� -I LI I 111 I I , I, -1- FOR REINF. INFO. 3" MIN. CLEARANCE V-4" (1 STORY) V-8" (2 ST 2RY) GARAGE DOOR SLAB RECESS ri SEE TYP. WALL SECTION FOR SCALE: N.T.S. S3 ADDITIONAL INFORMATION. 95% MODIFIED PROCTOR ASTM=1 I- D1557)m-r 4" 1'-4" TYPICAL EXTERIOR FRAME WALL FOOTING SEE TYP. WALL SECTION FOR ADDITIONAL SCALE: 3/4"=1'-0" SLAB INFORMATION. 1/2" GYP. BD. P.T. 2x „ HOLD GYP. BD. 1/2" FROM SLAB 0101, J CONT. BEAD SEALk INTERIOR -31- - /2" ot • a o '.• .... CONCRETE NAILS W 1 1/2' EMBEDMENT @ 12" O.C. STAGGERED, FROM BOTTOM PLATE TO CONCRETE (MIN. SHEAR 180# MIN. TENSION 120#) CONCRETE SLAB Ca A. ao •c E- C'J III= 12 M 6 MIL VAPOR BARRIER 4" 4" INTERIOR WALL SLAB STEP NON-BRG. SCALE: 3/4"=T-0" -2X STUDS @ 24" O.C. U.N.O. GARAGE �1`1/2" GYPSUM WALLBOARD U.N.O. W/ DRYWALL SCREWS @ 8"O.C. -INSULATION PER CHART ON FLOOR PLAN CONT. BEAD SEALANT E j 6x6W1.4xW1.4 I WWF OR FIBERMESH ) �, K S3 SCALE:3/4"=V-0" \ S3 NOTE: SEE SECTION C/S3 FOR ADDITIONAL INFORMATION SIMPSON SP1 w/ (10) 10d NAILS 2x P.T. PLATE SPACE ANCHOR a BOLTS 6" MAX FROM w END OF 2" x PLATE 0 LU p U a A LU ' 1=1 I I-1T I —I • U 2x BLOCKING HORIZONTALLY@ INTERVALS NOT EXCEEDING 10'-0" (R302.11) 1/2" GYP. WB (MIN.) @ GARAGE SIDE IF APPLICABLE. 5/8"DIA. EXPANSION BOLT @24 " O.C. W/ 7" EMBEDMENT (MIN. SHEAR 3500#, MIN. TENSION 2600#) 6x6W1.4xW1.4 N WWF OR FIBERMESH D-A I II T� III; o (2) #5 CONT. =1 I I III I I I , , I ON 3" CHAIRS (TYP.) 8 1-4 8 10" #6 REINFORCING BAR #5 STD. 90 HOOK #6 LAP SPLICE TYPICAL INTERIOR BEARING REBAR DETAILS rF WALL w/ UPLIFT rG SCALE: N.T.S. S3 SCALE: 3/4"=1'-0" S3 VARIES SEE PLAN 1 1/2" RECESS FOR 6 x 6 W1.4 x W1.4 FRAME -DOWN FALSE BEAM w/ (3) SEE ROOF PLAN S.G.D. (U.N.O.) WWF OR FIBERMESH 10d NAILS TO TRUSS TOP CHORD FOR TRUSS AT 24" O.C. MAX. CONNECTION INFO ° ' SEE PLAN FOR jk & LAYOUT DESIGN �;; a a d _ - TOP OF BEAM SEE ROOF PLAN C G d C 4 ' r (2) HTS20 FOR STRUCTURAL 4' BEAM SIZE & N a -Ir I ! CONNECTION INFO M - ° 8 T. 2x4 P.T. I 2x4 #2 SYP P.T. FRAMING w/ _ _ _' PLATE � a TnsSEE A/S3/J/S6 • MIN 7/16" O.S.B. SHEATHING FOR REINF. INFO. � fi�r-rr 8 O.S.S. z ATTACHED PER NAILING w SCHEDULE OPTION #1 Ir Q SEE TYP. WALL SECTION FOR ADDITIONAL COLUMN LOCATION Q > > J SEE PLAN FOR STRUCTURAL SLAB INFORMATION. g i COLUMN SIZE AND BASE o W CONNECTION INFO. SLAB STEP & RECESS S.G.D. rM SCALE:3/4"=1'-0" S3 SECURE 2x4 P.T. BTM. PLATE SEE DETAIL 16/D1 FOR w/ 1/4"x3" TAPCONS AT 8" COLUMN TO PORCH SILL - O.0MASONRY WALL AND ATTACHMENTS & 18/D1 PAD FOOTING FOR COLUMN TO BEAM TRIM PER PLAN 8" MASONRY WALL ATTACHMENTS EXTEND FILL CELLS TO FOUNDATION PAD _E z SQUARE CMU BLOCK BASE, CONT. FOOTING STEEL MAT REINFORCING. Q ' w SIZE VARIES PER PLAN i j w/ MIN. (2) #5 VERTICALS oo ? GRAD > FILLED SOLID (SEE PLAN FOR ,i' SIZE AND REINFORCEMENT) 0 • W aw0 v BRICK PAVERS or SLAB PER o o `" = • • • • - z V-0" FIN. FLR.Ah COMMUNITY SPECS " "' �¢ FOOTING v BEYOND ti . • .• . PAD REINFORCEMENT 3" MIN. CLEARANCE W. 4, ;: SEE FOUNDATION (SEE SCHEDULE) FOOTING WIDTH - .R .. . ,•. CONC. PAD INFO. SEE SCHEDULE TAPERED COLUMN FRAMING CD12 PATIO COLUMN FTG. DETAIL KN SCALE: 3/4" = V-0" SCALE: N.T.S. S3 N O N Q 3 ,o J Roo -'+ Q-0Mx -0 N � vo-- V N -.4LI c aW Q) ® ~E�5c > °, n vW D � A cE �c E c3 m o a 5 I c11, I. ,O•� i r; To the best of the Engineers knowledge, information and belief, the structural plans and specifications contained within these drawings comply with the 2020 Florida Building Code - Residential 7th Edition. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Enginee s signature and seal. W lotN pp a �E U II,, � CV V a) � G A>-0 N J LL N 0)���ZR v) M y - W a s Z 0 0 = r �o W D �� t Qo W � WIL J 0 LOM Z w V O z o� F= ❑00 2 W (D M o z z Q J a � m z o CS CAN V 0 w o N Lr N A� w 1- J EEo c� o � Q Y • N 01 14s o CD w _ 3 Z _l U_ cd E zo oo > N <� � OI o a � n3 o E �< -o U o� z t Wo o W, - G 0 10 Z� z m j �m <<w 8 o a° W T � 00 a LL N �? =3 o w a s To To o�<< N O > CD LO LO Q ��— 00 Y 6 Y r im m O N � ¢r I .Q CV ` O� LO •— � T E E � o Z m Z 3 U) E r E C a U 1 ¢ p JOB NO: 22-04746 SCALE : AS NOTED SHEET NO. S3 (MONO) (2) 2x6 OR (2) 2x8 TOP PLATE SEE PLAN 1/2" MINIMUM CEMENT FINISH (2) 2x HEADER TO SIT 2x6 / 2x8 WALL BEYOND FLUSH TO THE OUTSIDE STANDARD 3" DIA. TEE SEE PLAN FOR HEADER SEE PLAN FOR SIZE THREADED 3" DIA. EXTENSION - CONNECTION N, SCREW OFF CAP (3" DIA.) 2x DEAD WOOD @ MID FOR CLEAN -OUT POINT w/ (3)12d MIN. EXTENSION FROM DOUBLE 2x TOP TONEAILS SPACED EXTERIOR FACE OF BLOCK EVENLY WALL IS 1 1/2" MAXIMUM VENT OR 2ND FLOOR TYPICAL C.M.U. WALL 3/4" FURRING STRIPS 1/2" GYPSUM BOARD W/ DRYWALL SCREWS @ 8" O.C. OR 4d DRYWALL NAILS PLATE INTERIOR HEADER FLUSH TO OUTSIDE OPTION EXTENSION FROM EXTERIOR WALL 2x BLOCKING @ EACH END W/ 10d @ 4" O.C. FROM EACH HEADER FACE TO BLOCKING (2) 2x HEADER PER PLAN 2x BOTTOM PLATE W/(1) 10d @ 8" YARIES O.C. TO EACH HEADER FACE 2 x 6 (MIN.) FRAME WALL HEADER DETAIL SCALE: N.T.S. SL� 12 SEE TYPICAL WALL SECTION (TYP) SEE ELEV. PRE-ENGINEERED WOOD TRUSSES @ 24" O/C UPLIFT CONNECTOR (SEE SCHEDULE) DOUBLE 2x4 SPF. #2 TOP PLATE 2x S.P.F. STUDS @ 16" O.C. SINGLE 2x CONT. TOP PLATE W/ (2)12d INTO TRUSS ABOVE 2x CLOSURE WALL W/ STUDS @ 16" O.C. W/ SIMPSON SP2 w/ (12)10d (3)10d TOENAILS T&B NAILS AT EACH STUD AS REQ'D 2x BLOCKING @ MID POINT EVERY OTHER STTUD W/ (3) Od NAILS+ ++ F�-_ CRICKET AS REQUIRED SINGLE 2x CONT. BASE PLATE W/ (2)16d TO TRUSS BELOW 1/2" EXTERIOR GRADE SHEATHING FASTENED TO TRUSSES WITH 8d COMMON WIRE NAILS @ 4" O/C BOUNDARIES 6" O/C EDGES & 8" O/C FIELD SIMPSON SP1 w/ (10)10d NAILS AT EACH STUD 2x P.T. PLATE 5/8" x 10" "J" BOLT @ 24" O/C MAX W/ 8" EMBEDMENT 8"X8"X16" K.O. BLOCK W/ 1 #5 CONT. AND FILLED SOLID W/GROUT/I = 1 #5 VERT. IN CONC. FILLED CELL W/ STD. 90" HOOK IN K.O. BLOCK KNEE WALL ABOVE MASONRY WALL DETAIL MOUNTING BASE NOT SHOWN FOR CLARITY SEE DETAIL K/S4 SEAT FOR BLOCK IS POURED, IN PLACE CONCRETE GARAGE FLOOR SLAB TROWEL FINISH SEE GENERALNOTES SLOPE FORWARD FOR DRAINAGE BLOCKING (TYP.) �— ROOF TRUSS UPLIFT CONNECTOR (SEE SCHEDULE) MOISTURE BARRIER SCALE: N.T.S. LSEE PLAN FOR FOOTING DIMENSIONS GARAGE ENTRY FINISHED MASONRY DETAIL SCALE: N.T.S. CE OF BLOCK WALL IS 21/4" CL k DRAIN EXTERIOR WALL CLEAN -OUT q WALL '�:SCALE: N.T.S. S4 7 5/8" 8" 7 5/8" 8" 7 5/8" 8" 1ST COURSE 2ND COURSE 3RD COURSE MASON TO LAY BLOCK AS SHOWN ABOVE. EVERY COURSE MUST BE BONDED TO THE REFER TO WINDOW PRODUCT APPROVAL COURSE BELOW. EVERY THIRD (3RD) COURSE THE 11" DOOR JAMB WALL IS TO BE SHEETS FOR INSTALLATION INFORMATION BY WOVEN INTO THE MAIN FRONT TO REAR WALL AS SHOWN. MANUFACTURER. TYPICAL SECTION THRU WINDOW KB MASONRY LAYOUT D S4 SCALE: N.T.S. S4 KNOCK -OUT NOTCH LINTEL WHERE REQUIRED BLOCK W/ (1) #5 FOR CONCRETE PLACEMENT a a $ a a ' d o 0 8" STD. WHOOK 8" LINTEL BEAM W/ (1) #5 CONT. IN OPENINGS GREATER THAN 6'-0" WIDE (U.N.O. ON PLAN) OPENING FILLED CELL W/ (1) #5 VERTICAL SEE FDN. PLAN FOR LOCATION it NOTES: 1O FILL LINTEL AND ALL CELLS ABOVE LINTEL. NOTE: FOR BEAM DEPTH 22", PROVIDE A 4" x 4" INSPECTION PORT @ EACH VERTICAL REBAR & DIRECTLY ABOVE THE LINTEL. O VERIFY THAT ALL REINFORCEMENT HAS BEEN PLACED PROPERLY. O3 SEE FLOOR PLAN FOR ADDITIONAL INFORMATION. ® OPENINGS LESS THAN OR EQUAL TO 6'-0" IN WIDTH DO NOT REQUIRE ADDITIONAL STEEL REINFORCEMENT UNLESS NOTED ON FLOOR PLAN. TYPICAL FILLED LINTEL ASSEMBLY SCALE: N.T.S. WIDTH OF OPENING VARIES 4. FORM CONCRETE INSET TO 1/2"X9 1/2" PLYWOOD CREATE A SOLID BASE FOR SCRAP MATERIAL BLOCK WALL ABOVE, MOUNTING BASE SHOWN IN POSITION —2x6 MOUNTING BASE J w r > 0 FORM CREATES CONCRETE RECESS TO 2x4 (NOM.) RECEIVE GARAGE DOOR AND TO ALLOW FOR WATER SHED. KEEP STIFFENER BACK FROM SIDES ENOUGH TO ALLOW SPACE FOR FLAT MASONS TOOLS (THIS IS A RECOMENDATION FOR CONSTRUCTION OF THIS FORM. ANY MATERIAL OR CONSTRUCTION METHOD MAY BE USED PROVIDED END PRODUCT MEETS THE SHAPE AND DIMENSIONS OF THIS DRAWING.) GARAGE ENTRY FORM DETAIL �8x8x16 C.M.U. GARAGE DOOR GARAGE DOOR ROLLER _ CONNECTION ASSEMBLY GARAGE FLOOR TRAVEL DIRECTION OF GARAGE DOOR MOUNTING BASE DETAIL SCALE: N.T.S. , SCALE: N.T.S. -TRACK MOUNTING BRACKET GARAGE DOOR TRACK Q a a POURED CONCRETE BASE FOR BOTTOM OF MOUNTING B BLOCK WALL. RECESSED SPACE TO BE 2" ABOVE FINISHED FOR GARAGE DOOR AND WATER GARAGE FLOOR. SHED FORWARD THIS DRAWING. PARTIAL INTERIOR ELEVATION SCALE: N.T.S. T�7 SFF O �kk N 2x CRIPPLES @ ---I 16" O.C. W/ (2)12d TOENAILS T/B SIMPSON SP4 w/ (6) 10d x 1 1/2" AT EA STUD (USE SP6 FOR 2x6 WALL, USE SP8 FOR 2x8 WALL) 10d NAILS @ 8" O/C TYP, DOUBLE 2x CRIPPLE STUD TYPICAL (U.N.O.) SOLID AREAS ARE STEEL AND GROUT FULL 8x8x16 BLOCK DOOR OPENING VERTICAL JAM 5/8"DIA. x 8" J-BOLTS AT 6-3/4", 41-3/4", 71", AND 96-3/8" ABOVE GARAGE FLOOR. ALL J-BOLTS WILL BE IN FILLED CELLS (2,000 PSI MIN. CONCRETE). ANCHORS MAY BE COUNTERSUNK (BUT NOT REQUIRED) TO PROVIDE A FLUSH MOUNTING SURFACE. HORIZONTAL JAMBS DO NOT TRANSFER LOAD. 2x6P. J-BOLT TRACK BRACKET FOP 3 iARAG E OOR W/MOUNTING ANGLE NOTE: REFER TO GARAGE DOOR PRODUCT APPROVAL SHEETS FOR DOOR INSTALLATION INFORMATION PER MANUFACTURER. TYPICAL GARAGE DOOR BUCK K SCALE: N.T.S. S4 HEADER SUPPORT NO. OF JACKS & STUDS REQ. AT OPENINGS OPENING 2" x 4" WALL 2" x 6" WALL STRAPS JACKS STUDS JACKS STUDS SIZE EA END EA END EA END EA END SIMPSON 1' -4' (1) (2) (1) (2) (1)LSTA30 4'- 9' (2) (3) (2) (2) (1) LSTA30 9' -16' (3) (4) (2) (4) (2) LSTA30 FLAT STRAPS PER CHART ABOVE TO BE BENT OVER TOP PLATE ** HOLD DOWN CONNECTIONS NOT REQUIRED @ BEARING WALLS NOTED WITHOUT UPLIFT SEE FLOOR PLAN NOTES FOR REQUIRED CONNECTION 2-ROWS 12d NAILS STAGGERED @ 12" O/C EACH FACE OR 3-ROWS 12d NAILS STAGGERED @ 12" O/C FOR 2"xl0" OR GREATER HEADER (2) 2x HEADER SEE PLAN S4 INTERIOR HEADER: (1) 2x SILL PLATE W/ (2) 12d TOENAILS BOX HEADER • EXTERIOR HEADERS: ONLY (1) 2x SILL PLATE W/ (2) 12d TOENAILS • OPENING LARGER THAN 4 FT: (2) 2x SILL PLATE w/ SIMPSON LS30 w/ (6) 10d x 1 1/2" EACH SIDE ' 2x STUDS TYP. 00 SIMPSON HTT4 TYP. Op O,Q U.N.O. SEE N/S4 FN7N0 ** HOLD DOWN CONNECTIONS NOT REQUIRED @ P.T. BOT. PLATE BEARING WALLS NOTED WITHOUT UPLIFT WALL HEADER DETAIL ("Q SCALE: N.T.S. S4 _ SIMPSON SIMPSON SP4 SP2 2X STUDS @ 24" O.C. SEE TYPICAL WALL SECTION PRE-ENGINEERED WOOD 12 TRUSSES @ 24" O/C (TYP) SEE ELEV. UPLIFT CONNECTOR (SEE SCHEDULE) DOUBLE 2"x4" S.P.F. TOP PLATE 7/8" STUCCO FINISH PER ASTM C. 926 APPLY 3 LAYERS W/ TOTAL THICKNESS 7/8" OVER METAL LATH. FIRST 2 LAYERS 3/8" THICK EACH. 3RD LAYER 1/8" THICK OVER WATER RESISTIVE BARRIER SIMPSON SP2 w/ (12)10d NAILS AT EACH STUD TRUSS BOTTOM CHORD OR 2x4 1/2" EXTERIOR GRADE SHEATHING CRICKET AS BLOCKING W/ 2-16d TOE NAILS @EACH END FASTENED TO TRUSSES WITH 8d REQUIRED COMMON WIRE NAILS @ 4" O/C BOUNDARIES 6" O/C EDGES & 8" BLOCKING ( ) v O/C FIELD r 2x TOP PLATE 2X4 PT STUDS @ 16" O.C. 2-16d NAILS @ 24" O.C. OR (2) 2X4 PT STUDS UNDER HIP EQUAL TO TRUSS BOTTOM CARRIER/GIRDER TRUSS =_= CHORD OR BLOCKING SIMPSON HETA20 w/ (8) 10dx1 1/2" NAILS AT EA. TRUSS VERTICAL WEB 2x STUD @ 24" (24" O.C. MAX) w/ MIN. 4" EMBEDMENT L O.C. MAX. PROVIDE P.A.F. NAILS OR IN KO BLOCK AT EA. STUD MAIN SPAN 2x P.T. PLATE EQUAL @ 12" O.C. MOISTURE BARRIER ROOF TRUSS SEE A/S3 FOR, OR STAGGERED FROM BOT. UPLIFT CONNECTOR REINF. INFO. PLATE TO CONCRETE 8"X8"X16" K.O. BLOCK W/ 1 #5 CONT. (SEE SCHEDULE) _y /8"x10" "J" BOLT @ 24" O.C. MAX. MIN. (2) PER BOTTOM PLATE SECTION 2, P SIMPSON SP4 TRANSOM FRAMING SEE SECTION AA/S1 AND BB/S1 FOR ADDITIONAL DETAILS AND FILLED W/ GROUT 1 #5 VERT. IN CONC. FILLED CELL W/ STD. 90* HOOK IN K.O. BLOCK ALT. KNEEWALL ABOVE MASONRY WALL DETAIL SCALE: N.T.S. PIPE OR DUCT w/ PENETRATION THRU TOP PLATE w/ MORE THAN 500 OF TOP PLATE WIDTH INSTALL SIMPSON PSPN516Z w/ (12)16d NAILS TOP 2 ROWS 10d @ 3" O.C. (14 SPLICE NAILS TOTAL) EA. SIDE OF 1 • 48„ SPLICE STAGGERED ATTACH ALL J EXTERIOR STUDS W/ (4) 16d TOENAILS TO 70P PLATE NOTE: PLATE LENGTHS MUST BE BOTTOM SPLIC AT LEAST 4'-0" LONG. TYPICAL OVER STUD TOP PLATE SPLICE DETAIL rM SCALE: N.T.S. F= 2240 LBS SIMPSON rc l L C P.T. ATE 0I1vlrouly W14 SP2 allvlraVly ; SIMPSON SP1 SIMPSON SP4 10c ST io J M' TRANSOM FRAMING SEE SECTION J/SS AND K/SS FOR ADDITIONAL DETAILS RECESS LINTEL Ir NAILED INTO TRANSOM FRAMING SIMPSON SP4 2X8 P.T. BOTTOM P TE SIMPSON SIMPSON SP4 SP2 —� NAILED INTO TRANSOM FRAMING SIMPSON SP1 SIMPSON RECESS SIMPSON MPSON SP4 LINTEL TYPICAL INTERIOR NON - BEARING WOOD FRAME WALL SCALE: N.T.S. S4 2"x BUILT-UP COLUMN, SOLID MEMBER OR SPF) (3075# SPF) 3 (4565# SPF) 3 (5645# SPF) 3 (6970# SPF) IS (9335# SPF) N. 8" PDXIED A.T.R. I&NUT 'OXIED A.T.R. I&NUT DXIED A.T.R. I&NUT P4 ROOF TRUSS ABOVE 2X TOP PLATE OVERLAPPING 2X BLOCKING NAILS @ 6" NGGERED 3OLTS @ 24" O.C. �X 2X P.T. PLATE 5/8"x10" "J" BOLT @ 24" O.C. MAX. B C (MIN. (2) PER BOTTOM PLATE) SIMPSON SP4 1 NA 2X8 P.T. BOTTOM PLATE D 5/8"x10" "J" BOLTS @ 24" O.C. MAX. (MIN. (2) PER BOTTOM PLATE) O C -(2) 16d TOE NAILS EA. BLOCKING 2X8 WALL ABOVE ENTRY K.O. BLOCK W/(1) #5 CONT. & FILLED 5/8"X10" J-BOLTS @ 2'-0" O.C. MASONRY WALL Od ILS @ 4 10d NAILS @ 6" O.C. STAGGERED A STAGGERED TRANSOM FRAMING 0 o BEYOND. -PLYWOOD FASTENED TO TRUSSES WITH 8d COMMON WIRE NAILS @ 4" L PLYWOOD O/C BOUNDARIES 6" O/C EDGES o E SHEATHING & 8" O/C FIELD S4 B • SIMPSON SP4 w/ (6) 10d x 1 12" (USE SP6 FOR 2x6 WALL, USE PLYWOOD SP8 FOR 2x8 WALL) 0 SHEATHING • SIMPSON SP2 w/ (12) 10d NAILS MASONRY • SIMPSON SP1 w/ (10) 10d NAILS WALL BELOW 5/8"X10" J-BOLTS @ 24" O.C. MAX. (MIN. (2) PER BOTTOM PLATE) ALTERNATE: 5/8" DIA. ATR EPDXIED MIN. 6" INTO BOND BEAM @ 24" O.C. FRAMING DETAILS ABOVE ENTRY K"'R REV. 06.24.22 SCALE: N.T.S. C% e o Q o N 3N N "a to dd •s Z' w C � a; a co J Q$ 0 X m -0 N � �oY ® E t. u, U N v U 7 >ii.2 ? C 0 o � a � 5 10 f V, o. To the best of the Engineer s knowledge, information and belief, the structural plans and specifications contained within these drawings comply with the 2020 Flodda Building Code - Residential 7th Edition. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineers signature and seal. f/! W Q v E o N cy N N 0' CI c0 ik C 7 Lr'7 CD N LL Q m J iL a Y 2 J � Z o C Y f6 L-8 o 0 o j'f r- m J S �20�'a' J Z Z LLW Co 0 o w Cl)Z UA H Z N O U ❑❑❑ W V M � o � N Q � � WN V) z0Q) c� o +J (� w Q A U OQ) _x /� (! , w o [y N �N ~ (n w m . J E — L; 3 = t , U o y C U) N �CD0 s M s ti 0 w 12 M J y U_ (V g O ZR G cZ 0 �2=3 V of Wz z® as �_� aa0� Uo U z t wg �z �z � `� mo 10 Z i° wJj 2Z ¢ ZZo WEz Y_0 1m o o w << �� ;o Cl) r Q alp¢ Ov i Q > (fl LOm In E � Q cM 00 Co G C) J Y r r /y'� W co ,-- O N O) N r, Ln ,-- Q ca r Ea 00M o Z m Z :3W E T N c C rl 0 J Q 0 J JOB NO: 22-04746 SCALE : AS NOTED SHEET NO. S4 2x4 #2 SYP BLK'G @ 16" O.C. w/ (2)16d NAILS EA. END. 2x4 #2 SYP BLK'G @ 16" O.C. w/ (2)16d NAILS EA. END. 2x4 #2 SYP BLK'G @ 16" O.C. w/ (2) 16d NAILS EA. END. 2x4 #2 SYP BLK'G @ 16" O.C. w/ (2)16d NAILS EA. END. SEE SCHEDULE - [RSH] - ON FRAMING SHEET FOR SHEATHING AND SEE SCHEDULE - [RSH] - ON FRAMING SHEET FOR SHEATHING MAX' 9 SEE SCHEDULE - RSH ON FRAMING SHEET FOR SHEATHING [(MIN. SEE SCHEDULE - [RSH] - ON FRAMING SHEET FOR SHEATHING FASTENERS. (MIN. FIRST 4 BAYS) MAX. 9" AND FASTENERS. (MIN. FIRST 4 BAYS) AND FASTENERS FIRST 4 BAYS UNSUPPORTED, ) AND FASTENERS. (MIN. FIRST 4 BAYS) SEE STRUCTURAL NOTES AND NAILING TOENAIL w/ UNSUPPORTED, IF >9" SEE 10/S5 IF >9" SEE 10/S5 BACKNAIL w/ (2)16d NAILS MAX. 9" UNSUPPORTED, BACKNAIL w/ (2)16d NAILS MAX 9" SCHEDULE FOR SHEATHING DETAIL (2) 16d NAILS BACKNAIL w/ (2) 16d NAILS SEE STRUCTURAL NOTES AND NAILINGi\ IF >9" SEE 10/S5 SEE STRUCTURAL NOTES AND UNSUPPORTED, SCHEDULE FOR SHEATHING DETAIL NAILING SCHEDULE FOR SHEATHING IF >9" SEE 10/S5 45°± DETAIL 45' t SEE STRUCTURAL NOTES AND NAILING 2"x4" CROSS BRACE 2x4 CROSSBRACE SCHEDULE FOR APPROX. 8" FROM APPROX. 8" FROM SHEATHING DETAIL 2x4 KICKER 2x8 SYP#2 "L" BRACE TO RIDGE FASTENED AT RIDGE FASTENED AT @ 8'-0" 0/C. EXTEND AT LEAST 90% OF DOUBLE TOP PLATE EACH JOINT w/ (3) 10d / EACH JOINT W/ (3) 10d "L" BRACE TO EXTEND 2x4 CROSS BRACE WEB LENGTH & NOTCH AT 2x4 CROSS BRACE APPROX. 8" & (2) 1Od TOE NAILS @ / "L" & (2)10d TOE NAILS @ AT LEAST 90% OF WEB APPROX. 8 FROM BOTTOM CHORD (SEE TABLE) FROM RIDGE FASTENED AT EA. END BRACE TO EXTEND EA. END @ 48" O.C. LENGTH (SEE TABLE) RIDGE FASTENED AT SIMPSON H2.5A w/ (10) 8d EACH JOINT w/ (3)10d & (2) 10d (NOT REQ'D WHEN / AT LEAST 90% OF WEB 2x8 P.T. GABLE TRUSS EACH JOINT w/ 3 10d & () FROM LEDGER TO TOE NAILS @ EA. END GABLE IS 4'-1" OR LENGTH (SEE TABLE) SILL 1/2" CDX PLYWOOD OR (END d TOE NAILS @ EA. .• BLOCKING 2x FRAME WALL (SEE WALL SHORTER) �� GABLE TRUSS •• 7/16" OSB SHEATHING GYPSUM WALL BOARD � SECTION FOR SIZE & SPACING) 2x4 PANEL BLOCKING' 1/2" CDX PLYWOOD OR ATTACHED W/ 10d GABLE TRUSS 1/2" CDX PLYWOOD OR 7/16" @ 48" 0/C FOR THE / (2) 16d 7/16" OSB SHEATHING NAILS @ 6" O.C. EDGES 2"x4" PANEL BLOCKING @ 48" O.C. FOR THE FIRST 1/2" CDX PLYWOOD OR 7/16" OSB SHEATHING ATTACHED FIRST (4) ROWS OF NAILS ATTACHED w/ 10d NAILS AND 12" O.C. FIELD (4) ROWS OF TRUSSES FROM EA. END TYP. BOTTOM CORD ATTACHED W/ 16d TOENAILS 7OSB SHEATHING ATTACHED W/ 10d NAILS @ 6" O.C. EDGES TRUSSES FROM EA. END TYP. TOP & �� O. 6 O.C. EDGES AND 12" 10dX3" @ 3" 0/C (2) 2"x4" LEDGER (MATCH BOTTOM CHORD w/ 10d NAILS @ 6" O.C. AND 12" O.C. FIELD BOTTOM ATTACHED O.C. FIELD THROUGH CHORD SLOPE OF ADJACENT SCISSOR TRUSS) EDGES AND 12" O.C. FIELD 2 16d NAILS () W/ (2) 16d TOENAILS \ 2x4 "T" ON TOP OF PANEL 2x4 T ON TOP OF PANEL BLOCKING, INTO 2"x6" P.T. PLATE 2 x6 P.T. SILLNOTCH "L" BRACE HERE 2x4 PANEL BLOCKING @ 48" O.C. FOR 2x BLOCKING BLOCKING, FASTEN WITH FASTEN WITH 10dx3" @ 4" O/C SPACED WEEP SCREED 1/2" x 8" "J" BOLT @ 48" O.C. EEE:�� THE FIRST (4) ROWS OF TRUSSES 2x4 "T" ON TOP OF PANEL 10dx3" @ 4" 0/C @ 48" O.C. INSTALLED PER MANUF. WEEP SCREED FROM EA. END TYP. TOP & BOTTOM BLOCKING, FASTEN WITHI. SIMPSON HGAI OKT w/ (4)1/4"xl 1/2" SDS SCREWS TO MOISTURE BARRIER SIMPSON META12 w/ (7)10dx1 N- INSTALLED PER MANUF. ATTACHED w/ (2) 16d TOENAILS 1Odx3" @ 4" O/C TRUSS & (4) 1/4"x3" SDS SCREWS TO PLATES AT 24" O.C. 1/2"x 8" "J" BOLT @ 32" O.C. MINIMUM 6" FROM 0 C MAX w/ MIN 4" EMBEDMENT IN KO BLOCK - SIMPSON SP2 w/ (12) 10d 2x4 BLOCKING 2x4 'IT" BLOCKING @ 48" O.C. 16d NAIL "L" BRACE ATTACHED W/ 10d NAILS @ 4" O.C. TYPICAL GABLE TRUSS WEB DOUBLE "L" BRACING DETAIL 5 SCALE: N.T.S. S5 2x4 "T" BLOCKING 2x4 BLOCKING @ 48" O.C. "L" BRACE ATTACHED 16d NAIL W/ 10d NAILS @ 4" 0.C� TYPICAL GABLE TRUSS WEB J SINGLE "L" BRACING DETAILS 6 SCALE: N.T.S. DIAPHRAGM BLOCKING @ 48" 0/C GABLE TRUSS TRUSS VERTICAL PLATE SPLICES w/ 3/16"x2" 0 PLATE WASHER rl MOISTURE BARRIER 2x4 LEDGER (MATCH BOTTOM CHORD DBL. TOP PLATE NAILS AT EACH STUD (2) 2"x8" "L" BRACE J SIMPSON META12 w/ (7) ALTERNATE SIMPSON MSTAM24 w/ (7) 10d NAILS SLOPE OF ADJACENT TRUSS FASTENED WITH 3 NOTE: IF EMBEDDED 10dx1 1/2" NAILS AT EA. & (4) 1/4"x2 1/4" TITEN @ 4'-0" O/C ALIGNED WITH ) STUD WALL (SEE TYP. SEC.) ( ) 16d PER SIDE STRAP MISSED VERTICAL SECTION 1 TRUSS VERTICAL WEB (24" GABLE WEB SECTION r2 SECTION 3 SECTION rT� WEB, USE MSTAM36 w/ (7) O.C. MAX) w/ MIN. 4" SCISSOR GABLE "T" BRACE 7 1Od NAILS & (4) 1/4"x2 1/4" SCALE: N.T.S. S5 EMBEDMENT IN KO BLOCK SCALE: N.T.S.CALE: N.T.S. SCALE: N.T.S. AS PER HIB 91 SCALE: N.T.S. TITEN ON OUTSIDE . S5 S5 REV. 06.08.22 S5 S5 2x4 #2 SYP BLK'G @ 16" O.C. w/ (2) 16d NAILS EA. END. SEE SCHEDULE - [RSH] - ON FRAMING SHEET FOR SHEATHING MAX. 9" REFER TO DETAIL J AND FASTENERS. (MIN. FIRST 4 BAYS) UNSUPPORTED, ON SHEET S5 FOR N N IF >9" SEE 10/S5 X-BRACING, AND TOP `o SEE STRUCTURAL CHORD BLOCKING N 00 NOTES AND NAILING INFORMATION `� SCHEDULE FOR SHEATHING DETAIL BACKNAIL w/ 1 1 1/ " (2)16d NAILS WOOD TRUSSES 00 00 2"x4" CROSS BRACE APPROX. 8" FROM 2x4 RAT RUN BRACING RIDGE FASTENED ATEXTEND zzi BLEAST AT 24" O.C. ON TOP OF EACH JOINT w/ (3) AT 0o OF WEB BOTT, CHORD FOR 4 TRUSS SPANS 10d & (2) 10d TOE LENGTH (SEE TABLE) ATTACHED W/ 2 -16d NAILS EA. END °� GABLE TRUSS AT EA. TRUSS JOINT � �� �� (2) 2" x 4' LAMINATIONS W/ (1) ROW (3) 2 x 4 LAMINATIONS �� � W/ (1) ROW (3) 2 x 6' LAMINATIONS W/ (2) ROWS OF 2x4 PANEL BLOCKING E 1/2" CDX PLYWOOD OR 7/16" OSB SHEATHING ATTACHED SIMPSON HGAM10KTA OF STAGGERED 10d COMMON WIRE NAILS OF STAGGERED 30d COMMON WIRE NAILS STAGGERED 30d COMMON WIRE NAILS @ 48" 0 FOR THE (2) 16d NAILS W/ 1Od NAILS @ 6" O.C. W/ 2x4 BLOCKING @ 24' (D = 0.148", L = 3") OR EQUAL (D = 0.207", L = 41/2") OR EQUAL (D = 0.207", L = 41/2") OR EQUAL FIRST (4) ROWS OF E ES AND 12" O.C. FIELD O/C w/ (2)16d TRUSSES FROM EA. (4) 1/4"x1 1/2" SDS TOENAILS @ EA. END NOTES: END TYP. TOP & :r JACK TRUSS SCREWS 1) ADJACENT NAILS ARE DRIVEN FROM OPPOSITE SIDES 4) FOR 4-PLY, PROVIDE 1/4" DIA. x 5 1/2" LAG SCREWS OR EQUAL BOTTOM ATTACHED SEE PLAN FOR TO BLOCKING & (4) MASONRY WALL OF THE COLUMN (SPACE AS SHOWN FOR 3-PLY) w/ (2) 16d TOENAILS _,:: CONNECTION 1/4"x2 3/4" TITEN TO CMU ARCHITECTURAL FINISH 2) ALL NAILS PENETRATE AT LEAST 3/4 OF THE THICKNESS 5) FOR 5-PLY, PROVIDE 1/4" DIA. x 7" LAG SCREWS OR EQUAL ` OF THE LAST LAMINATION (SPACE AS SHOWN FOR 3-PLY) 2x4 T ON TOP OF PANEL EXT. WALL CONN. 3) EACH 30d COMMON NAIL MAY BE REPLACED W/ (2) 16d 6) REFER TO NDS SECTION 15.3 FOR ADDITIONAL INFORMATION BLOCKING, FASTEN WITH 1Odx3" @ 4" 0/C 2x4 BLOCKING W/ (2)12d TOENAILS NON - LOAD BEARING LOCATION D COMMON NAILS. (ONE INTO EACH OUTSIDE FACE OF B.U.C., SAME NUMBER OF ROWS, SAME SPACING) SECTION -- SEE TYP. WALL SECTION FOR ADDITIONAL INFORMATION. SCALE: 3/4"=1'-0" S5 TYPICAL NAILING SCHEDULES FOR BUILT-UP COLUMNS 8 9 11NIMUM 2x ,ROSS BRACING 5EE PLAN FOR OCATIONS) TOENAIL (2) 16d NA (2) 16d PER JOINT /— CONTINUOUS BOTTOM CORD BRACING 2"x4" MIN. SEE M/S5 CROSS BRACING DETAIL rj_� SCALE: N.T.S. 12" SH SCHEDULE ATTACHMENT t SYP BLK'G @ 16" O.C. i x 0.131" AILS EA. SIDE . 2x4 #2 SYP w/ 1 Od X0.131" @ 8" O.C. ALTERNATE NON -DROP GABLE END DETAIL 10 SCALE: N.T.S. 15 1 GABLE TRUSS S5 "L" BRACE W/ 1 Od @ 4" O.C. 12 (SEE SCHEDULE FOR SIZE AND LOCATION) 6.9 MAX. S5 GABLE END BRACING DETAIL S5 CONT. BEARING MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION SCALE: N.T.S. PRE-ENGINEERED WOOD TRUSSES SCALE: N.T.S. S5 OVERLAP TRUSS BRACING AT LEAST TWO TRUSS SPACES 6" OVERLAP - MINIMUM (2) 16d PER JOINT \— MINIMUM 2x4 TRUSS BRACING TRUSS BRACING OVERLAP DETAIL r M SCALE: N.T.S. S5 GABLE END BRACING DETAIL "L" BRACE W/ 10d @ 4" O/C (SEE SCHEDULE FOR SIZE AND LOCATION) 8d @ 6"O/C WOOD TRUSSES SIMPSON HGAMIOKTAw/(4) 1/4"x1 1/2" SDS SCREWS TO BLOCKING & (4) 1/4"x2 3/4" TITEN TO CMU 2 x 4 BLOCKING w/ (2)1Od TOE NAILS AT EACH END @ 24" 0/C (TYP) • Z w \-BRACING w/ (3)1 Od x 3" AT EACH CONN. @ 24" O/C MOISTURE BARRIER .BOND BEAM - MASONRY WALL ARCHITECTURAL FINISH EXT. WALL CONN. NON -LOAD BEARING LOCATIO (UNEVEN CLG.) SEE TYP. WALL SECTION FOR ADDITIONAL INFORMATION. SCALE: N.T.S. "L" BRACING REQUIREMENTS STUD SPACING NO "L" BRACE (1) 2"x4" (U.N.O.) "L" BRACE 2"x6" (U.N.O,) "L" BRACE 24" 0'0" - S-0" S-0" - 6-0" 6-0" & GREATER SCISSOR GABLE - (1) 2' x8" #2 S.P.F. @ EACH VERTICAL AND (2) 2" x8" FULL HEIGHT @ DIAPHRAGM BLOCKING NOTE: 1) "L" BRACE MUST EXTEND AT LEAST 90% OF WEB LENGTH EXCEPT, SCISSOR GABLE WHICH REQUIRES BRACE TO EXTEND FULL HEIGHT OF GABLE. 2) "L" BRACE TO BE FASTENED TO GABLE STUD WITH 1 Odx3" NAILS @ 4" 0/C. 3) SEE 6/S5 FOR MORE INFO. SIMPSON HGA10KT w/ (4) 1/4,k1 1/2" SDS^l ^ SCALE: 3/4"=1'-0" SCALE: N.T.S. I MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION 51MN5UN 5F LWl (12) 10d NAILS AT EACH STUD HIP FRAMING REFERENCE PLAN 20'-0" MAX 20'-0" MAX "X" BRACE SEE DET. J/S5 CONTINUOUS BOTTO CHORD BRACING 2X4 MIN. Ci w d O o O Z C� w w m - < 0 o ' O C1 w Q o Q O o w NOTE: ZTOP CHORD 2x4 #2 SYP BRACING 1) SEE TRUSS MANUFACTURER'S TRUSS ENGINEERING ZBOTTOM @ 16" O.C. MAX. FOR FIRST (4) CUT SHEETS FOR ADDITIONAL PERMANENT BRACING BAYS THAT MY BE REQUIRED CHORD GABLE END BRACING 2) "T" BRACING MAY BE USED IN PLACE OF PERMANENT @ 4'-0" O.C. MAX. FOR FIRST (4) BAYS BRACING PROVIDED IT EXTENDS OVER AT LEAST 90% OF THE WEB. REQUIRED MINIMUM PERMANENT TRUSS BRACING PLAN rL_N� AS PER BCSI SCISSOR TRUSS SCISSOR TRUSS W/ DROP CEILING BRACING DETAIL SCALE: N.T.S. 2X4 BRACING @ 48" O.C. CONTINUOUS TO FIXED LOCATION ATTACHED W/ (2) 1 Od AT EA. TRUSS (NOTE: BRACING MAY BE PLACED ON EITHER TOP OR BOTTOM OF THE BOTTOM CORD) COSMETIC DROP CEILING FRAMING MEAN ROOF HEIGHT UP TO 30'-0" SCALE: NTS SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION WOOD FRAMED GABLE END BRACING DETAIL MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES SCALE: N.T.S. FOR WIND SPEED SPECIFICATION N O Q o J —=i ai C b w ® a0o 4U Q70WX 5ILLa °-0R) U ��Y �gg 0 in p � C 4W us " 1 ocd N 5 � a o U � To the best of the Engineers knowledge, information and belief, the structural plans and specifications contained within these drawings comply with the 2020 Florida Building Code - Residential 7th Edition, Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. W 4 O N 8 o N U �_o C C 7 a0 co11 LL fA WrNic M Lu a a Z 5 Z _ ��rn r mo 300 0 o > c0 � uJ m J xU,Co LLl� Z ?0W N Cl)Z U O F Z OU ❑❑❑ W Ur <z N J. r, o G_ ° V 0 LL, o �v) c N N r UML cT a J - e ' U o 0 J< M M SS v ¢ Z Q " _. L _� <. z` Zo , - oa 1—t� j O I 0 L,O � U 0 CD CID�i t 2 H w� Q az cw ro , a= 3a 0' 9� o° Z z - �Z L VJ s 3 x �� a W ? M �t N �+ 0 3 p N > (O L J m m Q ^�^11 L 00 G co O r— 0 J Y r— CT^ Y T U) M W m T 0) I � N r Q CD T E E 00Z o m Z E r E E tl U J Q J JOB NO: 22-04746 SCALE : AS NOTED SHEET NO. S5 DOOR JAMB (REFER 1x4 1/2" DRYWALL DOOR JAMB (REFER 1x4 —1/2" DRYWALL TO PRODUCT DOOR JAMB (REFER*4""2X8 1/2" DRYWALL TO PRODUCT P.T. TO PRODUCT FOR CONN. APPROVAL FOR CON APPROVAL FOR CONN. P.T.. r 1 X 4 FURRING - X /1 3 1/4 LONG 3 6 0 rPPROVAL L FURR 3/16"0 X 3" LONG TAPCONS L FURRING (2) ROWS 3/16" x 3-1/2F TAPCON. INTO STAGGERED 16" °�1x8 P.T. TAPCON @ 16" O.C. &BLOCK@ FROM EACH END w/ M. SPACING „ 1 DETAIL O.C. 2-ROWS INTO 2 EDGE DIST. ATTACH PER MANUFACTURE MASONRY THROUGH 1-1 /211 DETAIL 1x8 w/ (2) ROWS 8d NALS " 3 DETAIL 1x4 P.T. & 1x8 P.T. STAGGERED @ 12" O.C. 3/16" x 3 -1/2" 1x4 P.T. DOOR JAMB (REFER TAPCON @ 16" TO PRODUCT O.C. & 4" FROM DOOR JAMB (REFER APPROVAL FOR CONN.r" DRYWALL DOOR JAMB (REFER*2" EACH END W/ MIN TO PRODUCT TO PRODUCTDGE DIST. APPROVAL FOR CONN. 2x8 P.T. w/ (2) ROWS 3/16"APPROVAL FOR CO (2) ROWS 3/16" x 3-1/2" x 3-1/2" TAPCON @ 16"1x4 O.C. & 4" FROM EACHTAPCON @ 16" O.C. & ENDw/MIN.2"EDGE DIST.FURRIN( 4" FROM EACH END w/ 2x8 P.T. ATTACH SECOND PLY w/ .T. AS REQ'D MIN. 2" EDGE DIST. (2) ROWS 10dx3" x 2x DETAIL 2 1/4" DETAIL STAGGERED @ 12" 0' 3-1/411 DETAIL BUILDOUT @ OVER SIZE DOOR -WINDOW ROUGH OPENINGS CC SCALE: N.T.S. SS 2x8 P.T. BUCK -CONNECT TO BLOCK SECTION W/ 1/4" x 31/4" TAPCON (1 1/4" MIN. A -A EMBEDMENT INTO BLK.) 1/4" MAX 1 X 4 FURRING SOLID BLKG. AT TOP BTWN. 1/4" x 31/4" TAPCONS BLOCK HEADER ARCH BLKG. & BUCK 1/2" DRYWALL 8d NAILS AT 8" O.C. AT BUCK 2 x 8 45" DIAGONAL (4) 10d NAILS INTO LEAVE A CUTOUT IN O.S.B. ON THE BRACE(S) 2 x 8 BRACE/ BLKG. INSIDE TO ALLOW FOR INSULATION 7/16" OSB TO BE INSTALLED BUILT UP PLWD. BUCK ARCH PANEL CUT HOLE IN O.S.B. FOR POLY -CELL IN THIS AREA 2 x 8 45 DIAGONAL BRACE AT EA. SCRIBE (NOTCH) FACE OF ARCH W/ (3)10d NAILS BACKSIDE TO FIT ARCH (4)10d NAILS INTO 2 x 8 AT EA. END CONNECT W/ 8d NAILS BRACE/ BLKG. INSTALL WDW. SCREW ANCHOR 2 x 4 SOLID BLKG. (FULL WIDTH OF WALL) BTWN. OSB PROVIDE WITHIN INTO ARCH BLKG. PER ARCH FACES W (4)10d NAILS THRU OSB INTO 2 x 8 4" MIN. OF BRACE BRACE INSTALLATION DETAILS A -A PROVIDE TAPCON PER WDW. INSTALLATION DETAILS OR THRU 1-1/2" THK. OR MORE BUCK WITHIN 6" MIN. OF START OF ARCH START OF ARC 4' MAX. RAD. ARCH DETAIL J SCALE: N.T.S. SS 2 x 8 BUCK - CONNECT TO BLOCK SECTION WITH 1/4" x 31/4" TAPCON (1 1/4" MIN. B-B 1/4" MAX EMBEDMENT INTO ) 2'-0" 8" BLOCK HEADER SOLID BLKG. AT TOP BTWN. ARCH 1 X 4 FURRING BLKG. & BUCK 8d NAILS @ 8" O.C. AT BUCK 2 x 8 VERT. W/ (2)10d NAILS AT EA. END PROVIDE 2 x 8 DIAG. BRACE B VERT. BRACES WHEN HGT. OF BRACE EXCEEDS 24" LEAVE A CUT OUT IN O.S.B. ON T 2 x 8 VERT. BRACE(S) INSIDE TO ALLOW FOR INSULATION TO BE INSTALLED BUILT UP PLWD. BUCK - SCRIBE (NOTCH) BACKSIDE 7/16" OSB ARCH PANEL TO FIT ARCH CONNECT W/ 8d NAILS 2 x 4 SOLID BLKG. (FULL WIDTH OF WALLS) BTWN. OSB ARCH FACES W/ (4)10d NAILS EQUAL EQUAL INSTALL WDW, SCREW THRU OSB INTO 2 x 8 ANCHOR INTO ARCH BLKG. PER INSTALLATION DETAILS ARCH DETAIL K B-B SCALE: N.T.S. SS PROVIDE 2x PROVIDE (2) MIN. CONT. W/ (3) TAPCON AT EA. SIDE 12d NAILS BUCK - (1) WITHIN 4" MIN. OF START OF ARCH START OF ARC 4' MAX. RAD. PROPER INSTALLATION MAX. 8" FILL SOLID BOTH CELLS #5 REB, (TYP,) STD. 90' HOOK (1 +5A NOTCH WEB AT FIRST 2 COURSI ;APACI I Y = 805 # FOR 1 STRAP = 1610 # FOR 2 STRAPS 1 PLY PRE-ENGINEERED TRUSS SIMPSON HM9KT w/ (4) 1/4"x1 1/2" SDS SCREWS & (5)1/4" x 2 1/4" TITEN (IF TRUSS IS 2 PLY INSTALL SIMPSON LGT2 w/ (16) 16d SINKERS AND (7) 1/4"x2 1/4" TITEN = 2150 #) BOND BEAM OR CAST IN PLACE BEAM RETROFIT TRUSS DETAIL N.T.S. 2X6 SYP #2 CONT. (MATCH TRUSS DEPTH IF TRUSSES USED) W/ (3) #6 X 4Y2' WOOD SCREWS @ 16" O.C. MAX. OR IF MASONRY WALL USE (1) SIMPSON 1/2" HD TITEN (CENTERED) w/ MIN. 4" EMBEDMENT AT 16" O.C. 12 JACK TRUSS PROVIDED BY SEE TRUSS COMPANY OR PLAN 2x6 #2 SYP @ 24" O.C. ROOF SHEATHING ATTACHED PER NAILING SCHEDULE (5)12d NAILS SIMPSON 2X6 TO 2X4 H2.5A w/ (10) 8d NAILS JACK TRUSS PROVIDED BY--/ TRUSS COMPANY OR 2x4 #2 SYP @ 24" O.C. '-0" MAX SEE PLAN 2X4 SYP #2 CONT (MATCH TRUSS DEPTH NOTE: SHED ROOF ENDS TO BE GABLE ONLY, CORNERS SHALL NOT BE FRAMED AS HIP. DESIGNED ONLY FOR THE INSTALLATION OF SHINGLE AND METAL ROOF FINISH I GLASS BLOCK INSTALLATION NOTES A) COVER SILL AREA WITH A HEAVY COAT OF ASPHALT EMULSION. ALLOW EMULSION TO DRY AT LEAST 2 HOURS BEFORE PLACING MORTAR. B) ADHERE EXPANSION STRIPS TO JAMBS AND HEAD. MAKE CERTAIN EXPANSION STRIP EXTENDS TO SILL. C) SET A FULL MORTAR BED JOINT, APPLIED TO SILL. D) SET LOWER COURSE OF BLOCK. MAINTAIN A UNIFORM JOINT WIDTH OF 3/8" PLUS OR MINUS 1/8". ALL MORTAR JOINTS MUST BE FULL AND NOT FURROWED. ALL MORTAR SHALL BE TYPE "S" OR "N". STEEL TOOLS MUST NOT BE USED TO TAP BLOCKS INTO POSITION. (PLACE EXPANSION STRIP A RUBBER CRUTCH TIP ON END OF TROWEL TO TAP BLOCK INTO POSITION.) DO NOT 20 ga. PANEL REALIGN, TAP, OR OTHERWISE MOVE BLOCK AFTER INITIAL PLACEMENT. FOR SOLID GLASS ANCHOR BLOCK IT MAY BE NECESSARY TO USE WEDGES IN THE MORTAR JOINTS OF THE LOWER COURSES TO PREVENT THE MORTAR FROM BEING "SQUEEZED" OUT. 1/4" EXPANSION BOLT (2 E) INSTALL PANEL REINFORCING IN EVERY OTHER MORTAR BED HORIZONTALLY AND IN JOINTS 9 ga, PANEL PER ANCHOR) IMMEDIATELY ABOVE AND BELOW ALL OPENINGS WITHIN PANELS. (THE SAME SPACING REINFORCING SHALL APPLY TO PANEL ANCHORS WHEN USED AT JAMBS AND HEADS IN LIEU OF CHANNEL (EVERY OTHER OR CHASE SURROUNDS.) RUN REINFORCING CONTINUOUSLY FROM END TO END OF PANELS. COURSE) EXPANSION STRIP LAP REINFORCING NOT LESS THAN 6 INCHES WHENEVER IT IS NECESSARY TO USE MORE THAN ONE LENGTH. DO NOT BRIDGE EXPANSION JOINTS WITH REINFORCING. INSTALL REINFORCING AS FOLLOWS: * PLACE LOWER HALF OF MORTAR IN BED JOINT. DO NOT FURROW. SEALANT * PRESS PANEL REINFORCING INTO PLACE. 6" MIN. LAP SPLICE W/ * COVER PANEL REINFORCING WITH UPPER HALF OF MORTAR BED AND TROWEL REINFORCING PANEL SMOOTH. DO NO FURROW. F) PLACE FULL MORTAR BED FOR JOINTS NOT REQUIRING PANEL REINFORCING - DO NOT FURROW. MAINTAIN UNIFORM JOINT WIDTH. 6" MIN. LAP G) SET SUCCEEDING COURSE OF BLOCKS. SPACE AT HEAD OF PANEL AND JAMBS MUST SPLICE NOTE: REMAIN FREE OF MORTAR. SEE GLASS BLOCK INSTALLATION NOTES. H) STRIKE JOINTS SMOOTH WHILE MORTAR IS STILL PLASTIC AND BEFORE FINAL SET. AT THIS TIME RAKE OUT ALL SPACES REQUIRING SEALANT TO A DEPTH EQUAL TO THE WIDTH OF THE SEALANT SPACES. REMOVE SURPLUS MORTAR FROM FACES OF GLASS BLOCKS AND WIPE DRY. GLASS BLOCK DETAIL TOOL JOINTS SMOOTH AND CONCAVE, BEFORE MORTAR TAKES FINAL SET. (REMOVE WEDGES FROM LOWER COURSES OF SOLID BLOCKS AND POINT THE VOIDS WITH MORTAR.) GLASS BLOCK SHALL BE INSTALLED PER THE FLORIDA BUILDING CODE RESIDENTIAL SECTION R160 1) AFTER FINAL MORTAR SET (APPROX. 24 HOURS), INSTALL PACKING TIGHTLY BETWEEN GLASS BLOCK PANEL AND JAMB AND HEAD CONSTRUCTION, LEAVE SPACE FOR SEALING. J) APPLY SEALANT EVENLY TO THE FULL DEPTH OF RECESSES IN ACCORDANCE WITH THE MANUFACTURER'S APPLICATION MANUAL AND INSTRUCTIONS. K) A MAXIMUM OF 60 SQUARE FEET OF GLASS BLOCK MAYBE INSTALLED IN ANY OPENING. FOR WIND SPEEDS UP TO 110 MPH*, PER PITTSBURG CORNING RECOMMENDATIONS FOR INSTALLATION OF GLASS BLOCK. IF TRUSSES USED) W/ (2) #6 X 4Y2' WOOD SCREWS @ 16" O.C. MAX. OR IF MASONRY WALL USE (2) 1/4" X 3 1/2" TAPCONS AT 16" O.C. SECTION @ ENTRY L SCALE: 3/4" = 1'-0" SS FILLED CELL PER FOUNDATION PLAN UNACCEPTABLE INSTALLTION *41** DO NOT DO THIS �R ' ±z. THE 000 :S 04* L 00 FILLED CELL INSTALLATION SEE ARCH PLAN AND PRE-ENG TRUSS DESIGN SEE NOTE 1 BELOW #5 REBAR (TYP,) s r TD. 90° HOOK (TYP.) SCALE: N.T.S. 2x SUB FASCIA ALUM DRIP EDGE BRG WALL TYPE ALUM FASCIA PER PLAN I I 1-3/4" TRIM PAINTED F CHANNEL, SS NAIL w/ 5/16" HEAD FASTENED PER DIA. @ 24" O.C. NOTE 2 BELOW CONT VENTED OR SOLID SOFFIT CONT 2x4 NAILED TO 2x BLOCKING NAILED TO TOP BLOCKING w/ 2-12d NAILS (**) CHORD EVERY OTHER TRUSS w/ 3-12d NAILS, TYP. (**) /1. G.C./ BUILDER TO VERIFY/PROVIDE SOFFIT MATERIAL SPAN CAPACITIES BASED / ON THE DESIGN PRESSURES SPECIFIED FOR COMPONENTS AND CLADDING LISTED IN THE DESIGN CRITERIA ON SHEET SN. 2. FOR SOFFIT ATTACHMENT AT WALL (PER ALPHA ALUM. INC. FL# 16544 R5 FL PRODUCT APPROVAL) F CHANNEL FASTENED TO: / - CMU w/ T NAIL .097" DIA. @ 24" O.C. w/ 5/8" MIN. EMBEDMENT - WOOD w/ (3) 16 GA. 3/4"xl/4" CROWN STAPLES @ 24" MAX. O.C. IN DIAMOND PATTERN / - - SUB FASCIA w/ 16 GA. 3/4"xl/4" CROWN STAPLE @ EACH GROOVE STRUCTURAL SOFFIT SF01 SCALE: 3/4" = V-0" (**) FOR ALUMINUM SOFFITS WITH SPANS REV. 09.23.2021 > V-4", INSTALL MID SPAN BLOCKING PER / THE SOFFIT FL PA INSTALLATION CRITERIA *REFER TO THE PRODUCT APPROVAL FOR INSTALLATION DETAILS.* / 2 X 4 #2 SYP SCAB TO SIDE OF 2 TRUSS AS SHOWN FOR O.H. UP TO 2'-6" x OVFl�y�A * DOUBLE 2x4 SCAB FOR 2'-6" TO 4'-0" O.H. MASONRY WALL. SEE PLAN FOR REINFORCING. PROVIDE LOWER HOOKED DOWEL W.W.M. AT PERIMETER WHERE THIS CONDITION #5 CONT. TOP & MID OCCURS WITH MIN. 3" COVER 6-0" p° IR!, r ° I I I-1 I -I " GRADEI- e N ° CV g • D \ e D (2) #5 REBAR. (1-STORY) 16" MIN. (1-STORY) (3) #5 REBAR. (2-STORY) 20" MIN. (2-STORY) WITH MIN. 3" COVER EA. WAY SECTION AT DEEP MONO FOUNDATION REV. 07.28.21 SCALE: 3/4" = V-0" + + + TRUSS 2X4 SYP EACH TRUSS CONNECTOR — SEE LINTEL SCHED. (2) 10d NAILS @ 8" O.C. TO TRUSS TOP CHORD PLYWOOD SHEATHING BLOCKING AS / + REQUIRED TO �\ + SUPPORT SOFFIT / CENTER SOFFIT PRECAST LINTEL �// SEE ELEVATION FOR OVER HANG (MAX. 4' _0") SECTION @ ROOF EXTENSION M SCALE: 3/4" = V-0" SS Qr:P cuGFT M ANIn SIMPSON HTT4 w/ (18)10d x 1 1/2" NAILS TO STUDS & (1) - 5/8" DIA. ALL THREAD ROD EPDXIED w/ SIMPSON "SET" EPDXY MIN. 6" EMBEDMENT E 3" MIN. EDGE DISTANCE RETROFIT FOR MIS MSTAM STRAP SCALE: 31Y - r Cr Z 0 a U_ 0 LU U U a 2"x BOT. PLATE W/ (2)10d @ 6" O.C. 3/4" PLYWOOD DECKING GLUED ATTACHED WALL SHEATHING TO AND NAILED W/ 8d COMMON @ 2X BOTTOM PLATE W/ 8d @ 4" 6" O.C. EDGES AND 12" O.C. FIELD O.C., 2 ROWS STAGGERED 2x BAND JOIST W/ FACE NAIL 10d @ TOP & BTTM CHORD, AND (8) FACE NAILS 10d @ TRUSS VERT. WEB METAL SEAT PLATE NOTE: LAP SHEATHING TO BOTTOM OF BAND JOIST TYPICAL SIMPSON HGAMIOKTA 12" 0 C @FIRST COURSE w/ (4)1/4x1 1/2" SDS SCREWS INTO BAND JOIST & (4) 1/4"x2 3/4" TITEN INTO K.O. BLOCK H RETROFIT FOR MISSING EMBEDDED STRAP >S SEE TYP. 2-STORY WALL SECTION FOR ADDL. INFO SCALE: N.T.S. FILL 1st4 COURSES SOLID W/GROUT FOR OVERHANGS BETWEEN OVER 1 1/2" CONTACT ENGINEER OF RECORD FOR FURTHER INSTRUCTIONS. RETROFIT WALL OVERHANG DETAIL (NTS FOR OVERHANGS BETWEEN 3/4" TO 1 112" NOTE: FOR OVERHANGS LESS THAN 3/4" - NO REPAIR REQ'D. 1 r-0rr 51-011 -INISH FLO >. ° #5 BAR ° CENTERED W/ ° e ' • .' 9 H IN TOP o ° .B . KNOCKOUT / N .e ° CHAIR BLOCK MONO FOOTING SIZE AND REINF. PER PLAN AND SECTION DETAILS CLEAN FILL .° s. ° o DIRT �' Z °. ° STANDARD 9(i HOOK 4 #5 BAR IN FILLED CELL, Sk STEMWALL FOOTING SIZE AND MONO TO STEMWALL FOOTING REINF. AND STEMWALL SECTIONN DDETAETAILS SCALE: 3/4" = V-0" )TE: IF RETROFIT FILLED CELL CONDITIONS EXCEED (3) PER PROJE( )INTACT ENGINEER OF RECORD FOR ADDITIONAL INSTRUCTION. EXISTING BOND BEAM. DRILL 3/4"x5" MIN. HOLE SET BAR IN EPDXY CAP TO PREVENT LEAKAGE TOP SPACE BETWEEN EXISTING GROUT & NEW GROUT MUST BE PACKED WITH NON -SHRINK GROUT (USUALLY ± 2") #5x6' EMBEDDED INTO EXISTING BOND BEAM FILL CELL FULL HEIGHT W/ NON SHRINK GROUT. #5x6' EMBEDDED INTO EXISTING FOOTING (2) #5x6' IN CONC. DRILL 3/4"4" MIN. HOLE FILLED CELL SET BAR IN EPDXY I EXISTING FOOTING RETROFIT FILLED CELL DETAIL 4" SAW CUT A SECTION 1 SCALE: N.T.S. SCALE: N.T.S. 0 N Cn _ q o Lu o e� q 0 m X e �y ca C� LL 0- ® M �o� o ANY v ®c CC C V1 N V Q > W Ep m O y, vCo-�A <,' '9 ' :1tF�rllla _ To the best of the Engineer's knowledge, information and belief, the structural plans and specifications contained within these drawings comply with the 2020 Florida Building Code - Residential 7th Edition. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. W 0 Oq EEo S cg O () GJ 0 J O w 7 rn co LL LL Z J u_ u_ Z rn 0. o O - .: W p — M n�F­C'z�Kw Z LLW M Z 0 N f=.. O U ❑0❑ Z W V M z N h M o z Erg QE3N N M z L Q� 0 o w "I-f--t+ (v C w � V N �N C N � y U w j _ E U o � C co x N 0 S� o co z Cl) J w ¢ 0, Z Z � L.� a C zo oo yry Z. Q. a q Em V z z® oa �- 03 O O C 20 Kr W 0 ;o U Q �6 Z C � a z K z d W _t C zm 3< U oa Z n o W U m Q W z U W VUi O WLL = oLL w 3 �0 << o v ola ;g a ° 3 y O LO LO Q M 00 (c O r j O J ,- CT r Y W co r O N 0*)QI N r- LO T a CD T o Z cc Z E E vi C a 0 Z a o JOB NO: 22-04746 SCALE : AS NOTED SHEET NO. SS A l l - I _l 1 CROSS BRACING DETAIL (TYP.) 1 SCALE:NTS SEE ROOF PLAN SHEATHING 2X4 BLOCKING BETWEEN TRUSSES SECT. A -A G.T. ADD 2X4 ALONGSIDE TOP CHORD WHEN REQ'D TO PREVENT PLYWOOD SPAN FROM EXCEEDING MAX 24" SPAN (EITHER SIDE OR BOTH IF REQ'D) PROVIDE 2X4 MIN. BLOCKING AT Q OF HIP/RIDGE, TYP.BETWEEN TRUSSES W/ (2) 12D NAILS EACH END TO TRUSS TOP CHORD TYP. �A TRUSS SSES (2) 12D NAILS —t' AT 12" O.C. MAX HIP/RIDGE BLOCKING DETAIL SCALE:NTS HIP G.T (2) 2x8 #2 SYP w, O.S.B. FLITCH PI TOP @ TRUSS 8 U.N.O. ON ROOF PLAN TYPIC WALL NOTE: PENDING BEAM BEARING LOCATION, THE BEAM CAN SIT ON TOP OF COLUMN w/ (2) SIMPSON HTS20 w/ (24) 10d x 1 1/2" NAILS EACH SIMPSON HU46/HUC46 w/ (8) 16d NAILS TO POST & (4) 10d NAILS TO BEAM SUPPORT COLUMN BUILT-UP (2) 2x4's OR 4x4 w/ (2) 10d NAILS @ 8" O.C. EACH PLY (SHOWN AS 4 x 4) (2) SIMPSON HETA20 w/ (8) 10d x 1 1/2" NAILS EACH - OR (2) SIMPSON MSTAM36 w/ (7) 10d & (4) 1/4"x2 1/4" TITENS EACH TIE BEAM BEAM @ RAISED ENTRY MASONRY WALL 4 SCALE:NTS EXTERIOR ATTACHED SCHEDULE JACK TRUSS (AS SHOWN) OR GABLE END SEE TRUSS LAYOUT CLIP EACH TRUSS (SEE ROOF PLAN FOR TYPE) FRAME OUT TO BLOCK EDGE SEE PLAN FOR BEAM SIZE 2x SPF #2 AT 16" O.C. BUILDER FRAME RADIUS AS REQUIRED KNEEWALL a ENTRY FRONT WALL SCALE:NTS TRUSS NOTES. TYP. HAND FRAMING ABOVE TRUSS 1. WOOD TRUSS ERECTOR SHALL PROVIDE BRACING ACCORDING TO ANSI/TP1-2014 CONV. FRAMED RIDGE 2X4 STUDS & PLATES AT 2'-0" O.C.MAY BE NAILED EACH DIRECTION TYP. U.N.O. SIMPSON LSTA18 VERTICAL SCAB 2 x 6 w/ (12) 1Od NAILS SEE PLAN L. (TRUSS PLATE INSTITUTE) NOTE THAT THE COMBINED WIND AREA IS GREATER w/MIN. (4) 12d WHEN #2 SPF 48" O.C. W/ 4 CENTERED AT SIMPSON HUC410 w/ (14) FOR CANT. BEFORE THE ROOF SHEATHING IS APPLIED, AND BRACING SHALL THEREFORE BE IT LANDS NEXT TO 2x8 BLOCKING NAILED @ 10d TOP &BOTTOM() SPLIT TIE 1INTO BEAM SEE 6d HEADER E6) INSTALLED AS THE TRUSSES ARE ERECTED. INADEQUATE BRACING IS THE MOST PRE-ENG. TRUSS EACH SIDE w/ 3 12d NAILS BEAMS TOGETHER COMMON CAUSE OF ACCIDENT IN WOOD TRUSS CONSTRUCTION. FULL BUNDLES () OR SIMPSON H2.5A w/ ROOF PLAN FOR MORE OF PLYWOOD SHALL NOT BE PLACED ON TRUSSES. THIS CONSTRUCTION LOAD WHEN REQUIRED w/ (2) (10) 8d NAILS INFO SHOULD BE LIMITED TO 8 SHEETS OF PLYWOOD ON ANY PAIR OF TRUSSES & /2HTS20 w/ (24) 10d x 1 1" N SHALL BE LOCATED ADJACENT TO THE SUPPORTS. NO EXCESS CONCENTRATION 1 1/2" NAILS EACH SEE FLOOR PLAN FOR OF ANY CONSTRUCTION MATERIAL (SUCH AS GRAVEL OR SHINGLES) SHALL BE PLACED COLUMN SIZE & BASE ' OO FLITCH PLATE RECI SEE FLOOR PLAN CONNECTION INFO REQ'D ONLY WHEN 2x4 #2 SYP NAILER. NAIL ON THE TRUSSES IN ANY ONE AREA THEY SHALL BE SPREAD OUT EVENLY OVER COLLAR TIE FOR COLUMN SIZE INDICATED ON BM. TO STUDS w/ (3) 16d AT A LARGE AREA SO AS TO AVOID OVERLOADING ANY ONE TRUSS. 'k EVERY 3rd & ADDITIONAL INFO. SCHEDULE/PLAN EACH STUD - TOENAIL ROOF AND EXTERIOR 2. ALL BRACING (DB,CB,BB) SHOWN ABOVE SHALL BE IN ADDITION TO CONTINUOUS RAFTER 7/16" OSB FLITCH PLATE SEE FLOOR PLAN FOR LATERAL BRACING SPECIFIED BY THE TRUSS MANUFACTER ALL LATERAL BRACING REQ'D ONLY WHEN COLUMN SIZE & BASE EACH TRUSS TO NAILER SHEATHING ATTACHED SPECIFIED BY TRUSS MANUF. SHALL HAVE ADDITIONAL DIAGONAL BRACES AT 20'-0" OPTION A SCHEDULE/PLAN DICATEDNBM OPTION B CONNECTION INFO OPTION C. w/ (3) 10d PER NAILING SCHEDULE O.C. MAXIMUM. 2x4 SPF 2 (2) #7 x 3-1/2"SEE 2ND FLOOR WALL SECTION 3. ALL BRACES SHALL BE 2X4 NOMINAL DIMENSION LUMBER & SHALL BE ATTACHED w/ (3) 12d WOOD SCREW EACH FOR ADDITIONAL INFORMATION NAILS AT EACH TRUSS INTERSECTION. CB TRUSS OR SIMPSONCOMMON B M . TO POST ATTACHMENTrA AT 48 4. ADDITIONAL BOTTOM CHORD BRACING SHALL BE INSTALLED AS REQUIRED BY TRUSS w/ (10) $d NAILS DESIGN WHEREVER ADEQUATE STRUCTURAL CEILING ARE NOT TB AT " O.C. SEE ROOF PLAN SCALE: 3/4"=1'-0" ATTACHED DIRECTLY TO THE BOTTOM CHORD OF THE TRUSS. DB B FOR BEAM SIZE & IF 2x DOUBLE LEDGER, BM. SPLICE OVER 5. PROVIDE TRUSS BLOCKING AT ALL TRUSS BEARING SUPPORTS WHERE TRUSS BEVEL CUTS CONNECTION INFO. ATTACH FIRST PLY DEPTH EXCEEDS STANDARD HEEL HEIGHT. SEE TYP. TRUSS BLOCKING DETAILS (OPTIONAL) CENTER OF POST w/ D 16d NAILS H N PRE-ENG. TRUSS A A END OF TRUSS THEN 2X4 BLOCKING SEE PLAN FOR ATTACH SECOND PLY 2X4 DIAGONAL AT 8'-0" O.C. BETWEEN EA. TRUSS CONT. ROOF SHEATHING AT TRUSS TOP TOP OF BEAM MAX & EACH END ALTERNATE CHORD AT ALL HAND FRAMED AREAS TYP. w/ (3) ROWS OF 16d NAILS AT 24" O.C. DIRECTION TYP. A DIAGONAL 2x8 #2 SPF RIDGE BEAM SIMPSON LUS26 w/ (8) 10d NAILS • MAX8'-0" WOOD 2x6 #2 SYP RAFTERS FOR SPANS 4FT SIMPSON MTS18 w/ (14) OR IF 2 PLY TRUSS SIMPSON MTRUSS "�'� TO 8FT 2X4 RAFTERS FOR SPANS LESS 10d NAILS TYP. U.N.O. SEE PLAN FOR SIMPSON LUS26-2 w/ (8) 16d NAILS TO SEE FLOOR FRAMING PLAN THAN 4FT @ 2-0"0.C. MAX. w/ (3) 10d CANTILEVER IF MTS18 w/ (14) LEDGER AND J/S6 FOR MORE INFO. SEE FLOOR PLAN FOR INDICATED COMMON TOENAILS TO TIE BEAM 10d NAILS VERIFY WITH PLAN FOR COLUMN SIZE & TYP. U.N.O. 2X10 #2 SYP CONT. LEDGER w/ (3) LOCATION AND DIRECTION 2X4 CONT. AT CONC. MASONRY ADDITIONAL INFO. 1/2" X 4 1/2" LAG SCREWS ATTACH LAG SCREWS INTO END OF EACH (IF PARALLEL SEE 2/D2 FOR FLOOR TRUSS, 24" O.C. MAX. (AT BLOCKING INFO) T& B CHORD BEARING SUPPORT STEEL OR WOOD (WOOD COLUMN SHOWN) MIDDLE EACH SIDE OF G.T. INSTALL (4) LAG MASONRY WALL SCREWS EACH SIDE) (TYPICAL) SEE FOUNDATION SECTION AT LOW ROOF A -A ALTERNATE BLOCKING CORNER 9 DETAIL @ INTERIOR BEARING 3 PLAN FOR MORE INFO SCALE: NTS 5" WOOD TRUSS SCALE:NTS COMMON B M . ATTACHMENT �18 A PROVIDE BLOCKING AT ALL TRUSS BEARING SCALE:NTS SUPPORT WHERE TRUSS DEPTH EXCEEDS TYP. WOOD TRUSS BLOCKING DETAIL STANDARD HEEL HEIGHT SCALE:NTS VARIES» 1 1 2x STUDS @ 16" O.C. ROOF SHEATHING SEE 1/S5 FOR ( ) ATTACHED PER ADDITIONAL SEE PLAN FOR w/ SIMPSON SP1 w/ 10 10d 8d NAILS AT VALLEY TRUSS NAILS AT BASE & SIMPSON N SP2 w/ 12 10d NAILS AT TOP O NAILING SCHEDULE OUTLOOKER ( ) INFO. 2x4 #2 SPF BRACING @ � EXTERIOR SHEATHING INFO. 4 O.C. 16" O.C. W/ (4) 12d �� —1/t— COMMON TRUSSES. ATTACHED PER 2x BLOCKING BETWEEN STUDS TOENAILS TO TOP —�-- —>�— SEE TRUSS PLAN 2x4 STUDS w/ SIMPSON r NAILING SCHEDULE TO TRUSS W/ (2) 12d TOENAILS PLATE & (2) 12d END MIN. (2) 2x4 FOR CONNECTION SP1 w/ (10) 10d NAILS EACH END ( BETWEEN TRUSSES STRUCTURAL SHEATHING NAILS TO TRUSS SPF TOP INFORMATION. AT BASE SEE J/S6 FOR GABLE (2) 12d NAILS TO EACH VERTICAL ATTACHED PER NAILING BOTTOM CHORD LOW ROOF/WALL SCHEDULE PLATE MORE INFO. v TRUSS SHEATHING ATTACHED STUD) -- VARIES SEE PLAN PER NAILING SCHEDULE 2x BASE PLATE W/ (2) 12d lgL VARIES W/ - - FOR WALL LOCATION 2x4 BASE PLATE W/ 1/2" PLYWOOD NAILS @ 16" O.C. ALONG W/ ROOF SLOPE SIMPSON LSTA30 w/ SIMPSON MTS12 w/ (14) 10d x (22) 10d NAILS OR (2) 16d NAILS TO i 1 1/2" NAILS TO BLOCKING SIMPSON MTS12 w/ EACH COMMON BELOW @ 16" O.C. WOOD WALL MIN. 2x4 #2 SPF STUDS @ � (14) 10d x 1 1/2 TRUSS/ FRAMING NAILS -v OR TRUSS. 2X4 CONT. W/ (2) — 16" O.C. W/ EXTERIOR TO FLOOR GIRDER TYP TOP & BOTTOM r SEE PLAN 16d COMMONS NAILS EACH Y SHEATHING ATTACHED BELOW @ 16" O.C. PER NAILING SCHEDULE & • MASONRY WALL BELOW: SIMPSON STUD TYP. T&B % (3) 12d TOENAILS TO a.. HETA16 w/ (9) 10d x 1 1/2" NAILS @ PLYWOOD SEE PLAN FOR PLATE BELOW MASONRY WALL 4'-0" O.C. TO GABLE TRUSS FLOORING TRUSS OR _ _ _ _ ROOF SYSTEM TOP OF WALL OR BEAM • BEAM BELOW: SIMPSON HTS20 w/ a -- - o MIN. 2x4 #2 SYP P.T. PLATE 16" FLOOR SYSTEM FLOOR GIRDER SEE TRUSS PLAN (24) 10d x 1 1/2" NAILS @ 4'-0" O.C.° W/ 1/2"X8" EPDXY ANCHOR SEE PLAN FOR SEE PLAN FOR TO GABLE TRUSS LOW ROOF TRUSS W/ (2) 2x6 BLOCKING UNDER FLOOR G.T. MASONRY WALL SEE @ 3" FROM EACH END & DIRECTION CONNECTION COMMON TRUSS RAISED BOTTOM CHORD 2nd FLOOR WALL w/ SEE PLAN PLAN FOR MORE 16" O.C. MAX. �° SEE ROOF PLAN EXTENSION SEE TRUSS SIMPSON LUS24-2 w/ (16) SHEAR TRANSFER INFO. •p SECTION @FLOOR FOR CONNECTION MANUF. SPEC'S FOR 16d NAILS AT EACH END CONNECTIONS TO G.T. EXTERIOR. WALL SECTION ENTRYr_8"N�CONNECTION r22N)i,SECTION AT HIP GABLE 12 SECTION @ BUMP OUT 39 SCALE:NTS SCALE:NTS SCALE: NTS SCALE:NTS SCALE: NTS DETAILS & SECTIONS - Q c 0 .p CV W � S CM W •--F_o O ` co 4p c� � co y�. N L cam m O r_ o c Ln V � C) m , � o a u � G .••�ty,SF'• o •'•c`v ' L� << 1 w Qj 101 To the best of the Engineers knowledge, information and belief, the structural plans and specifications contained within these drawings comply with the 2020 Florida Building Code - Residential 7th Edition. Engineers signature and seal is only for the structural engineering portions of the drawing pages bearing Engineers signature and seal. rn W vE o Q 8 8c.4 N W rn 0 00 (A LL v Oq - N 0 Q LL a a a LL Z c 0 o 0 Co m o m O: t 7 '� N t0 ` o Co J Q W og�� ¢ m W Z Cl) LL �rw 0. U =- N z a 0 Z co F 000 _ W 0 Z N Z n a N V) Z aC1 � o (D4-1 u- U w CD —71 V O�W s �U ! Ly N N U W J EEo L U = c ® O = 0 • O M LL E Zo oo > n Z� Q a O rO w ?® - F Q o E ao xo as oa -O O ° °< Z � ru .� t w o a z a a oY�LL Q p Z�� r9 J hm <w S � Z s° W C/) a W d Z �w oz 3 �O ¢¢ x �O r� � zl� ar L o LOLO Q c� H CO O T_ : C) J Y r 0 r r^ v, m C�fl Ir— < O N 00 O N LO T— (0 T E c 00 o Z `° Z E T `m a E U J Q J JOB NO: 22-04746 SCALE : AS NOTED SHEET NO. D 1 o+ C) 3 =I LO `v a co 0 0 J 0 I 3 x rn LO CCr W r. s1 THESE DETAILS ARE GENERIC AND MEANT TO SHOW GENERAL FLASHING AND WATERPROOFING METHODS TO BE USED. 3/8" CEMENT PLASTER 12 MIL DRYLOK CMU - MASONRY BLOCK EXTREME WINDOW FASTENER 1) SEALANT AT 4) SEALANT JOINT WINDOW BUCK TO OUTSIDE EDGE OF MASONRY WINDOW BUCK , 2) SEALANT JOINT 5) SEALANT FROM INSIDE EDGE OF WINDOW FRAME WINDOW BUCK ACROSS WINDOW BUCK AND EXTEND TO WINDOW FRAME MASONRY ATTACHED PER CODE 6) TOOLED SEALANT REQUIREMENTS BEAD BRIDGING CLADDING AND WINDOW FRAME 3) SEALANT WINDOW FRAME T( WINDOW BUCK ALL THE WAY AROUND, INCLUDING SILL. SCS 06_05 CMU INSTALLATION 6 POINT BUCK AND FENESTRATION INSTALLATION AND INTERFACE JAMB, SILL AND HEAD DETAIL APPROVED SHEATHING APPROVED HOUSEWRAP STRUCTALATH TWIN TRACK 2.5 3/4" CEMENT PLASTER 12 MIL (min) DRYLOK EXTREME APPROVED FLASHING TAPE "V" SEALANT SOCKET WITH TOOLED APPROVED SEALANT WEATHER ✓E BARRIER & tARILY SECURE WEATHER r RESISITIVE 1 BARRIER WOOD FRAME CONSTR. TAPE EXTERIOR SELF -ADHERED FLASHIN 3 SHEATHING BY LAPPING DOWN -� OVER RIM JOIST AND UP WALL BY 6 IN. (ASSEMBLED WINDOW) HEAD FLASHING TIE-IN INSTRUXTI( 1. Cut, fold up & temporarily secure resistive barrier above header to allow for flashing installation 2. Self -adhered flashing plus head flashing under weather resistive barrier 3. Fold weather resistive barrier back over head flashing and seal with tape WEATHER RESISITIVE BARRIER SEAL TOPS OF JOI: UNDER DECKING ED FLASHING (SEE DETAIL WP07) 0 o� SELF -ADHERED FLASHING Scale: NTS FLANGED WINDOW FLASHING INSTALLATION AFTER WEATHER RESISTIVE BARRIER EXTERIOR SHEATHING REFER TO TECHNICAL LETTER ON CHEMICAL O COMPATIBILITY SELF -ADHERED FLASHING DO NOT FLASH OVER BOTTOM NAILING FLANGE SELF -ADHERED FLASHING HALF ROUND WINDOW SCS 06_02 WINDOW FIN INTERFACE WITH EXTRUDED SHOULDER SELF -ADHERED FLASHING PRODUCTS DETAILS SELF -ADHERED FLASHING NAILING FLANGE r n.nuw i .nvinw SELF -ADHERED FLASHING DECK JOIST 2x FRAMEWALL TILE FINISH WATER RESISTIVE BARRIERS ARE REQUIRED BEHIND STUCCO 1/2" DUROCK- PER THE FBC RESIDENTIAL 7TH EDITION (2020) Detail Instructions Refer to the number marked as in each detail that corresponds to the f numbered items in the list o instructions below: 1. Install self -adhered flashing in order as shown by numbers 8" CMU 2. Install flashing and weather resistive barrier to form water shedding laps 4" OR 8" CMU 3. Self -adhered flashing can be substituted for building paper (PER SEAT DEPTH)- 4. Split the release paper using the ripcord (Split release on demand, FILL WITH GROUT - embedded in the adhesive layer) - for ease of installation and to minimize scoring cuts 5. Remove all release paper per standard installation instructions and adhere to substrate using a square piece of flashing material (6" x 6" Minimum) SLOPED MUD BED- 6. Fold as shown by arrows 7. Angle of corner may vary, adjust folding of the flashing accordingly to fit tight to corner VINYL SHOWER PAN 8. Mechanically fasten as necessary SLOPE a a WEATHER RESISTIVE BARRIER SELF -ADHERED FLASHING EXTERIOR DOOR WITH DECK - SECTION A EXTERIOR SHEATHING 3/4%1" BEAD OF CONSTR. ADHESIVE TO BE APPLIED UNDER THRESHOLD OF DOOR AND RETURN UP JAMB 6". USE LIQUID NAIL BRAND OR EQUAL WEATHER PROOF CAULKING SECTION -A (SEE DETAIL SELF -ADHERED FLASHING 1 Q 2 SEAL TOPS OF JOISTS UNDER DECKING (SEE DETAIL WP07) SELF -ADHERED FLASHING ' EXTERIOR DOOR WITH DECK E AM SELF-ADHER V-4" PER PLAN 1'-0" PER PLAN SHOWER SEAT I a a G SELF -ADHERED FLASHING OUTSIDE CORNER Q w (n m a z gl -Ii z Z J a a Lu w a a 2 W � W W U LU w DJ L w U) I 0 I� /- DOOR ROUGH OPENING WINDOW UNIT SLOPE FLASHING REQUIREMENTS 0.3 in: 12.0 in R703.1 General. Exterior walls shall provide the building with a weather -resistant exterior wall envelope. The exterior wall envelope shall - (0.6 cm: 30.5 cm) include flashing as described in Section R703.4. 3/4"-1" BEAD OF CONSTR. ADHESIVE TO BE APPLIED UNDER SELF -ADHERED FLASHING THRESHOLD OF DOOR AND RETURN UP JAMB 6". USE LIQUID R703.1.1 Water resistance. The exterior wall envelope shall be designed and constructed in a manner that prevents the accumulation of NAIL BRAND OR EQUAL WEATHER EXTERIOR water within the wall assembly by providing a water-resistant barrier behind the exterior cladding as required by Section R703.2 and a means PROOF CAULKING CEMT. FIN. SELF -ADHERED FLASHING BUILDING PAPER of draining to the exterior water that penetrates the exterior cladding. WIRE LATH R703.2 Water -resistive barrier. One layer of No. 15 asphalt felt, free from holes and breaks, complying with ASTM D226 for Type 1 felt or SUBFLOOR other approved water -resistive barrier shall be applied over studs or sheathin of all exterior walls No 15 as halt felt shall be a lied 9 p Pp horizontally, with the upper layer lapped over the lower layer not less than 2 inches. Where joints occur, felt shall be lapped not less than 6 inches. Other approved materials shall be installed in accordance with the water -resistive barrier manufacturer's installation instructions. The RIM JOIST No. 15 asphalt felt or other approved water -resistive barrier material shall be continuous to the top of walls and terminated at penetrations and building appendages in a manner to meet the requirements of the exterior wall envelope as described in Section R703.1. 1 R703.7.3 Water -resistive barriers Water -resistive barriers shall be installed as required in Section R703.2 and, where applied over wood -based sheathing, shall include a water -resistive vapor -permeable barrier with a performance at least equivalent to two layers of Grade 2 Q D paper. The individual layers shall be installed independently such that each layer provides a separate continuous plane and any flashing (installed in accordance with Section R703.4) intended to drain to the water -resistive barrier is directed between the layers. SELF -ADHERED FLASHING 1 CEMT. FINISH SILL/ POTSHELF/ CHIMNEY SHOULDER ZW Exception: Where the water -resistive barrier that is applied over wood -based sheathing has a water resistance equal to or greater than that of 60-minute Grade D paper and is separated from the stucco by an intervening, substantially nonwater-absorbing layer or designed drainage space. MECHANICALLY FASTEN IF RUBBERIZED RUBBERIZED ASPHALT INSTALL SELF -ADHERED NEEDED IN CORNERS ASPHALT ADHESIVE ADHESIVE THROUGH SELF -ADHERED g pp g, yflashing, y g FLASHING JAMB &HEAD R703.4 Flashing. Approved metal flashing, vinyl self -adhered membranes and mechanical) attached flexible flashing shall be FLASHING, SEE FLASHING SELF -ADHERED FLASHING applied shingle -fashion or in accordance with the manufacturer's instructions. Metal flashing shall be corrosion resistant. Fluid -applied FLANGED WINDOW pp g g pp (SEE DETAIL WP01) membranes used as flashing shall be applied in accordance with the manufacturer's instructions. All flashing shall be applied in a manner to SCORED prevent the entry of water into the wall cavity or penetration of water to the building structural framing components. RELEASE :�L PAPER Self -adhered membranes used as flashing shall comply with AAMA 711. All exterior fenestration products shall be sealed at the juncture with SELF -ADHERED FLASHING, _moo (BEFORE FOLDING, SCORE the building wall with a sealant complying with AAMA 800 or ASTM C920 Class 25 Grade NS or greater for proper joint expansion and RELEASE PAPER TO EXPOSE EXTEND A MINIMUM 6" ADHESIVE AS SHOWN) contraction, ASTMC1281, AAMA 812, or other approved standard as appropriate for the type of sealant. Fluid -applied membranes used as VERTICALLY FROM BOTTOM OF flashing in exterior walls shall comply with AAMA 714. The flashing shall extend to the surface of the exterior wall finish. Approved flashings THRESHOLD shall be installed at the following locations: 1.1.Exterior window and door openings. Flashing at exterior window and door openings shall extend to the surface of the exterior wall finish or to the water -resistive barrier complying with Section 703.2 for subsequent drainage. Mechanically attached flexible flashings 2 shall comply with AAMA 712. Flashing at exterior window and door openings shall be installed in accordance with one or more of the following: 5 1.1 The fenestration manufacturer's installation and flashing instructions, or for applications not addressed in the fenestration 4 manufacturer's instructions, in accordance with the flashing manufacturer's instructions. Where flashing instructions or details are not provided, pan flashing shall be installed at the sill of exterior window and door openings. Pan flashing shall be sealed or 1 6 sloped in such a manner as to direct water to the surface of the exterior wall finish or to the water resistive barrier for 2 subsequent drainage. Openings using pan flashing shall incorporate flashing or protection at the head and sides. 1.2 1.2. In accordance with the flashing design or method of a registered design professional. SELF -ADHERED FLASHING 1.3 1.3. In accordance with other approved methods. 1 INSIDE CORNER �' 1.4 In accordance with FMA/AAMA 100, FMA/ AAMA 200, FMA/WDMA 250, FMA/AAMA/ WDMA 300 or FMA/AAMA/WDMA 400. 2.2.At the intersection of chimneys or other masonry construction with frame or stucco walls, with projecting lips on both sides under stucco copings. Ground 3.3.Under and at the ends of masonry, wood or metal copings and sills. 4.4.Continuously above all projecting wood trim. 5.5.Where exterior porches, decks or stairs attach to a wall or floor assembly of wood -frame construction. 1 6.6.At wall and roof intersections. Water Resistant Barrier 7.7.At built-in putters. :LF-ADHERED FLASHING ETCH IHERED FLASHING 1 2 4 5 FOUNDATION WEEP SCREED STRIP OF SAF DRAINAGE PLANE WRB BOND BREAK WRB SF LATH WRAP DP WRB ONTO THE VERTICAL SURFACE TO TOP OF FLANGE AS AN AIR BARRIER 3-1/2" INCH FLANGE THIS NATU DO Ni DRIP ACCE SOFFIT/CANTILEVER Lath Sheathing Stucco LEGEND SELF ADHERED FLASHING (SAF) DRAINAGE PLANE (DP) WEATHER RESISTANT BARRIER (WRB) BOND BREAK WEATHER RESISTANT BARRIER - SELF FURRING (SF) LATH PLASTER ACCESSORY SHEATHING,'OSB', PLYWOOD, DENSGLASS 1RAL FRAMING JRAL SHEATHING SAF E PLANE WRB EAK WRB Cement Plaster in accordance with ASTMC926 over wood 2nd floor THESE DETAILS ARE GENERIC AND MEANT TO SHOW GENERAL FLASHING AND WATERPROOFING METHODS TO BE USED. Cement Plaster over block 1 st floor 7/8" Cement Plaster in accordance with ASTMC926 Felt backed metal lathe in accordance with ASTMC1063 Building Paper 7/16" O.S.B. sheathing Metal Flashing Weep Screed Installed As Per Manufact. Specs. Maintain Bottom of Weep Screed 1 1/2" to 2" Above Roof Sheathing Note: The building paper and metal lath must be installed over the top of the weep screed. WEEP SCREED DETAIL SCALE: NOT TO SCALE 7/8" Cement Plaster in accordance with ASTMC926 Felt backed metal lathe in accordance with ASTMC1063 Building Paper 7/16" O.S.B. sheathing Stampede or similar cauk bottom joint only Weep Screed Installed As Per Manufact. Specs. 1/2" Cementitious Decorative Finish All inside and outside corner will need to be miter cut and caulked all butt joints need to becaulked using Stampede or sim. caulk for all 4V M Q O W S a0 o 00CD 0m Q X •a tt G LL a > 70 QJ N CJ �y V y�Y c Li na) c) O CO C N U Q 2 > U � a) a7 a) 0 >�. 0 cn I= c E m ° �a 5 0 N O N N co O To the best of the Engineers knowledge, information and belief, the structural plans and specifications contained within these drawings comply with the 2020 Florida Building Code - Residential An Edition. Engineers signature and seal is only for the structural engineering portions of the drawing pages bearing Engineers signature and seal. 0 W E Q o c0N ,cj S N N v NN ( u M- (a tl a) �� � N O � M toNo° %LL LL "aw N ro v LL w a O a LL �n 2 s O O Z cc c L CCv �_•� a' O X O ED o m U, 7�N� cO Q a m Z N M Z ILwW O Z O F Z OU ❑�❑ Z W V M z N M o z m N Q ct � ti V) z � o u- a--+ (D L1J m o u 0Q) w s V) r_ • N 2 U o c U, 0 ®0 N � r o to M J 0 Z w Z Q � E a �a �z >� zo z® Q o o� _ U O I_ p to I� a O w CL)t wo w " C /� c ao 3< mo of Z0".mCIO 'aw �� OQ � <z <o U W U5 �� o LL w a 1w x J o J << ao v zl< o O N > CU '^ u , Lid CD 2 Q o H L_ 00 O J Y r � r 0 m T 4-J O N c) I Q .0 N n L0 T Q C.0 r QO 0 z E r m a ci a 15 JOB NO : 22-04746 SCALE : AS NOTED SHEET NO. WP PRODUCT APPROVAL SPECIFICATION SHEET(2024) As required by Florida Statute 553.842 and Florida Administrative Code 913-72, please provide the information and approval numbers on the building components listed below if they will be utilized on the construction project for which you are applying for a Cate o /S ubcategory Manufacturer Product Description Approval Numbers Test Pressures Ex .Date 1. EXTERIOR DOORS A. SWINGING ThermaTru Fiber -Classic and Smooth -Star (NON -IMPACT) FL20461.1 +67.0/-67.0 psf 12/31/2026 ThermaTru Fiber -Classic and Smooth -Star (IMPACT) FL20468 +67.0/fi7.0 psf 12/31/2026 ThermaTru Fiber -Classic and Smooth -Star (IMPACT) FL20470 +80.0/-80.0 psf 12/31/2026 B. SLIDING MI Windows and Doors Series 420 FL15332.1 - FL15332.5 +40.0/40.0 psf 12131/2024 PGT Series 5570 FL242.6 +60.0/-60.0 psf 8/4/2026 Pella Corporation Standard Performance Sliding Patio Door FL1824 +40.0/-40.0 psf 2/16/2032 C. SECTIONAL Wayne -Dalton Series 8000/8100/8200 #1105 (8X7) FL8248.3 +31.0/-35.0 psf 12/31/2035 Wayne -Dalton Series 8000/8100/8200 #1123 (16X7) FL8248.10 +30.0/-33.5 psf 12/31/2035 Wayne -Dalton Series 8000/8100/8200 #1124 (16X7) FL8248.11 +34.4/-38.3 psf 12/31/2035 D. METAL LOUVERED DRS Curries Division of AADG, Inc 607,707,727,747,and 847 Single & Pairs of Doors FL11537.1 N/A (see inst sht) 12/31/2025 2. WINDOWS A. SINGLE HUNG MI Windows and Doors 3540 Single Hung FL17676.11 +30.0/-30.0 psf 4/12/2027 MI Windows and Doors 3540 Series Fixed Glass FL17845.1 +35.01-50.0 psf 4/12/2027 MI Windows and Doors 1620 Series Single Hung Non -Impact FL21637.4 +35.0/-47.0 psf 8/1/2027 MI Windows and Doors 1620 Series Single Hung Impact FL21637.8 +35.0/-47.0 psf 8128/2027 MI Windows and Doors 1620 Series Fixed Non -Impact FL21639.1 +55.0/-55.0 psf 8/17/2026 MI Windows and Doors 1620 Series Fixed Impact FL21639.6 +55.0/-55.0 psf 8/15/2026 PGT Series 5500 FL239.2 N/A 7/30/2025 Pella Corporation Series 10/20 FL11206 +35.0/-35.0 psf 6/17/2027 B. HORIZONTAL SLIDER MI Windows and Doors Series 188 FL15351.1 +55.01-55.0 psf 12/31/2035 Pella Corporation Series 10/20 FL11161 +30.0/-30.0 psf 7/27/2024 Pella Corporation Series 10 Sliding Window FL12811 N/A 5/25/2031 C. FIXED MI Windows and Doors Series 3500 HP PW FL17845.5 +70.0/-75.0 psf 4/30/2026 PGT Series 5520 FL243.5 N/A 4/30/2025 Pella Corporation Series 10/20 FL6694 +50.0/-50.0 psf 7/15/2024 Pella Corporation 10 Series Flange Fixed FL16280 N/A 5/25/2031 D. MULLION MI Windows and Doors Series 5764 FL15353.2 N/A 12131/2024 PGT Series 5500 FL261.1 N/A 5/26/2026 E. OTHER 3. PANEL WALL A. SIDING James Hardie Building Prod. Cemplank Lap Siding and HardiePlank Lap Siding FL13192.1 - FL13192.2 N/A 3/31/2026 B. SOFFITS Alside Solid and Vented Vinyl Soffit FL15272.1 - FL15272.2 +75.0/-75.0 psf 12/31/2026 Alpha Aluminum, Inc. Solid and Vented Aluminum Soffit FL16544 R5 +54.2/-54.2 psf 7/30/2033 C. OTHER 4, ROOFING PRODUCTS A. ASPHALT SHINGLES GAF 3 Tab, Dimensional FL10124.1 N/A 1211612025 B. UNDERLAYMENTS Tamko (for Shingle Root) 151b Felt Underiayment FL12328 N/A 6/1/2026 Plyglass USA, Inc. (for Tile Roof) POLYSTICK TU MAX FL5259 N/A 12/4/2026 C. ROOFING FASTENERS NOT USED D. ROOF VENTILATORS Thompson Arch Metal Comp. Off Ridge Vents FL16918.1 - FL16918.4 N/A 9/9/2026 Florida Metal Products, Inc Vent RV10 FL21580.3 N/A 12/31/2024 Lomanco, Inc DA4 Exahust Vent FL17202.1 +97.5l-97.5 psf 12110/2025 E. ROOFING TILES Boral Tile Villa 900 FL7849.27 - FL7849.28 N/A 12/31/2025 Boral Tile Saxony 900 FL7849.16 - FL7849.20 N/A 12/31/2025 F. METAL ROOF Drexel Metals, Inc. DMC 100NS, DMC 150SS, DMC 1755, DMC 2005, DMC 5V FL17679.1 +0/-180 12/31/2025 April 12, 2024 PRODUCT APPROVAL SPECIFICATION SHEET(2024) As required by Florida Statute 553.842 and Florida Administrative Code 913-72, please provide the information and approval numbers on the building components listed below if they will be utilized on the construction project for which you are applying for a Cate o /S ubcategory Manufacturer Product Description Approval Numbers Test Pressures Exp. Date 5. SHUTTERS A. STORM PANELS Global Protection Products Galvanized Steel Storm Panels FL15076.1 - FL15076.2 N/A 12/31/2024 All American Shutters & Glass Galvanized Steel Storm Panels FL17869.1 N/A 12131/2024 6. STRUCTURAL COMPONENTS A. WOOD CONNECTORS/ANCHORS Simpson Strong -Tie Titen Stainless Steel Concrete & Masonry Screw (TTN-SS) FL2355 N/A 12131/2024 Connector Screws FL9589 N/A 12/31/2026 Take -Up Devices FL10007 N/A 12131/2026 Hold-downs FL10441 N/A 12/31/2026 Accents Angles FL10446 N/A 12131/2026 Hip Ridge Connectors FL10447 N/A 12131/2026 Coiled Straps FL10456 N/A 12/31/2026 Face -mount hangers FL10531 N/A 12/31/2026 Top flange hangers FL10667 N/A 12131/2026 Adjustable Post Base FL10860 NIA 12/31/2026 Bearing Plate FL10866 N/A 12/31/2026 Joist Hanger FL11468 N/A 12/31/2024 Truss Anchor FL11473 N/A 12/31/2024 Tension Tie FL11496 N/A 12/31/2026 Anchor Bolts FL13628 N/A 12/3112026 Straps FL13872 N/A 12131/2026 Masonry Beam Hangers FL13904 N/A 12/31/2024 Strong -Drive SDWC Screw FL13975 N/A 12/31/2026 Truss Plate FL15363 N/A 12/31/2026 Adhesive Anchor for concrete FL15730 N/A 12/31/2026 Adhesive for masonry FL16230 N/A 12/31/2026 Tapping Screws FL16937 N/A 12/31/2026 Bypass Framing Connector FL35320 N/A 12131/2026 B. TRUSS PLATES ITW Building Components Alpine Truss Plates FL1999.1 - FL1999.4 N/A 12/31/2024 MiTek Industries, Inc. Truss Plates FL2197.1 - FL2197.5 N/A 12/31/2024 C. ENGINEERED LUMBER Weyerhaeuser Rim Board, LVL, PSL, LSL FL6527.1 - FL6527.5 N/A 3/31/2025 D. MATERIAL Cast -Crete Corp. High Strength Concrete Lintels FL158 N/A 5/21/2027 Commercial Concrete Products, Inc. High Strength Concrete Lintels FL1774 NIA 1/26/2034 The products listed below did not demonstrate product approval at plan review. I understand that at the time of inspection of these products, the following information must be available to the inspector on the jobsite; 1) copy of the product approval, 2) the performance characteristics which the product was tested and certified to comply with, 3) copy of the applicable manufacturers installation requirements. Further, I understand these products may have to be removed if approval cannot be demonstrated during inspection. APPLICANT SIGNATURE DATE N a) (n O U C O O C .� Ca - CU U o ca M c o 0 t- ca o CU E o o a� Cn a z Z W J L (D Z ,,,,,cET NO. PA 1.0 PP 846s 36l 40. Caw d� wQ(�wp� Convw+ g