Loading...
HomeMy WebLinkAbout3111 Moulden Hollow DrALL WORK SHALL COMPLY WITH PPEVAILING CODFS FLORIDA R010NO CODE, NATIO-14AL ELECTr " AND THE CITY OF 4lZPHYRHILL6 ORDINANCES REVIEW D T / -�q ­q IA E I CITY OF ZEIPWAPLUL 4 r� S PLAN WMIN m �T ABBREVIATIONS A.B. Anchor Bolt F. P. Fireplace P.T. Pressure Treated Abv. Above F.O.M. Face Of Masonry Pwd. PowderRoom A/C Air -Conditioner Ft. Footl Feet Red. Radius ADJ. Adjustable Ftg. Footing Ref. Refrigerator A.F.F. Above Finished Floor A. H. U. Air Handier Unit FIX Fixed Req'd. Required ALT. Alternate GaIv. Galvanized Rm. Room B.A. Base Cabinet G.C. General Contractor Rnd. Round BF Bifold Door G. F. I. Ground Fault Interrupter R/S Rod and Shelf Bk Sh BookShelf G.T. Girder Truss SD. Smoke Detector Bm. Beam Hdr. Header S. F. Square Ft. Bot. Bottom Hgt. Height Sh. Shelves B.P. Bypass door HB Hose Bibb SHT Sheet BRG. Bearing Int. Interior S.L. Side Lights Cir. CIg. Circle Ceiling K/Wall Kneewall S. P. F. Spruce Pine Fir C.1 Control Joint K.S. Knee Space Sq. Square Col. Column Laun. Laundry S.Y.P. Southern Yellow Pine Comm. Community Lay. Lavatory TB Towel Bar Comp. Compressor L. F. Linear Ft. Temp. Tempered C.T. Ceramic Tile LL Lintel Length Thik'n. Thicken D. Dryer LT. Laundry Tub T.O.B. Top of Block DB Door Bell Mas. Masonry T.O.M. Top of Masonry Dec. Ded. Decorative Dedicated Outlet Max Maximum T.O.P. Top of Plate Dbl. Double M.C. Medicine Cabinet TR TOWEL RING Dia. Diameter Mfgr. Manufacturer TP TOILET PAPER Disp. Disposal Micro. Microwave Trans. Transom Window Dist. Distance Min Minimum Typ- Typical D.S. Drawer Stack M.L. Microlam U.C. Under Counter D.V. Dryer Vent Mir. Mirror UCL Under Cabinet Lighting D.W. Dishwasher U. N. 0. Unless Noted Otherwise Ea. Each Mono Monolithic V. Shower Valves E.W. Each Way N.T.S. Not to Scale VB Vanity Base Elec. Electrical Opn'g. Opening van. Vertical Elev. Elevation Opt. Optional V.L. Versalam Ext. Exterior PC. Piece VTR Vent through Roof Exp. Expansion Ped. Pedestal w Washer FBC Florida Building Code PH PHONE w With Fin. FIr. Finished Floor P.L. Parallam WIC Water Closet F.G. ixed Glass PLF Pounds per linear foot W.A. Wedge Anchor FIr. Floor Pit. HI. Plate Height Wd Wood Fdn. Foundation Pit Sh. Plant Shelf WP Water Proof FIr Svs Floor Svstem PSF Pounds per square foot REVISIONS 08-20-15 1.00 NEW BASE PLAN 12-08-15 2.0 12-22-16 3.0 FRAME-WAL REVISIONS A1B1 ELEV. REVISIONS 1Z I IN, 1111 IN IN L - - - ------- 1% LM Ir= I *J 111*J ** I ism 2575 INDEX OF DRAWINGS SHEET DESCRIPTION SHEET No. CS COVER SHEET 1 MAIN FLOOR PLAN 1.1 UPPER FLOOR PLAN 2 INTERIOR ELEVATIONS 3.1 EXTERIOR ELEVATIONS 3.2 EXTERIOR ELEVATIONS F1 FOAM DETAIL 4 MAIN ELECTRICAL PLAN 4.1 UPPER ELECTRICAL PLAN 5 ROOF PLAN 6 FOUNDATION PLAN 7 MAIN FRAMING PLAN 7.1 ROOF FRAMING PLAN 8 LINTEL DETAILS SN STRUCTURAL NOTES SN1 DETAILS S3 STEM DETAILS S4 DETAILS S5 DETAILS S6 DETAILS ST STAIR DETAILS SS RETROFIT DETAILS D1 SECTIONS & DETAILS WP WATERPROOFING DETAILS PA1.0 PRODUCT APPROVAL NUMBERS PA1.1 PRODUCTAPPROVAL NUMBERS PA1.2 PRODUCTAPPROVAL NUMBERS PA1.3 PRODUCTAPPROVAL NUMBERS MEAN ROOF 15 FT. HIGH TYPICAL FOR SINGLE STORY HOMES MEAN ROOF 30 FT. HIGH TYPICAL FOR 2 STORY HOMES THIS DRAWING AND DESIGN IS VALID FOR 12 MONTHS AFTER THE DATE IT IS SIGNED AND SEALED OR WHILE CURRENT CODE IS VALID Notice to Builder & All Subcontractors It is the intent of Designer/Engineer listed in the titleblock of these documents that these documents be accurate, providing Licensed Professionals clear information. Every attempt has been made to prevent error. The Builder and all subcontractors are required to review all the information contained in these documents, prior to the commencement of any work. The Designer/Engineer are not responsible for any plan errors, omissions,or misinterpretations undetected and not reported to the Designer / Engineer prior to construction. All construction MUST be in accordance to the information found in these documents. Any questions regarding the information found in these plans should be directed to our Office at (407) 880-2333 immediately. No backcharges will be considered for reimbursement by the Designer/Engineer without advanced notification and approval by the Designer/Engineer. Payments will be made in accordance to the terms of the agreement. Log Z cn -8 Z Z __J Z C1 Ln 0 4-J LU C) 0 U-1 (DV) CLI E 0 Lh (10 C) 9M cli LU E 8 as W M 0) M C M C) M -0 M 6,or- CC4 =' C), :Su.00 g''i < con 0 AI 8 D. N.C.$ E, C got/ '0011ill Cb-i �&ag- 0- , * , * . Z I Z gut LLI Z t To the best of the Engineer's knowleU tl rmation, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code Sth Edition (2014) Residential. Engineer's signature and seal Is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. Z r-4 0 (L) N 4.J C) > CD C) 4-J V) M Ln V) N Q) In U- F-rn CL ()o Z < Z E Z LLJ C:) -J C:) W tD u, 10 E60 1HI HN F- 818 L1J LU U) Z V) LLJ 0 r14 0 U 0 Z 13 uJ IR P! C) Z UJ In LU [i --I Lij Z < X < Z n1 uJ f� 00 M Cal to U') Z Z U.J 0 rn lr-� T-4 :5 0. SCALE AS NOTED DATE 2/24/2014 TECH: MJAMES VERSION NO 2x0 SHEET NO. CS YP @ 2 STORY H.B. C� r - - - - - - 2, 24 OPT. REF. 04 CN 16"DEEP 5-SH 11" 2x6 WALL 1266 B.F 1 4'-8" 111 ED 12-4- 2368 00 1 1W 3: (D CO 1 (P __ KITCHE 8'-I'FL�T LG. H1 0 =1 z __ - -.-- 7 M 36 .3 F - - - - - - - - - - - - 7 - - - - - - - - - - - Li L - rCC EDGE OF SLAB 2" fv__� BEYOND WALL 04 20'-8" X 11 W X 04 4'-0.. _j __j 4 4'-8" V-2" V-15" 2 CAR GARAGE PATIO DINING ROOM 8'-8" FLAT CLG. CARPET 9 00 &D LO LO (3) 2X4 #2 SPF W/ (3) 16d TOENAILS @ 8'-8" FLAT CLG. BUILDER TO PROVIDE 2 6" APPLIANCE PROTECTION WH EN REQUIRED PER FBC 0 (3) 2X4 #2 SPF W/ 16d TOENAILS @ BASE W.H. D S3 L - - - - - P W/' (3) 2X4 #2 SPF W/ (3) 16d TOENAILS 4AILS f\ @ BASE 9 b c� BASE TYP @ 2 STORY �j 8 u_ I-: I-: d 8 _j LO _j U_ X-8- T-8" S-15" F70YER 11 8'-8" FLAT CILG. 3068 7\ TILE L. 6-101" -4 L -(2) #5'S b F� TRY, HDR AT 7-4- 8'-8" FLAT CL OP 5-SH FAMILY ROOM I- 8'-8" FLAT CLG. CARPET 2x6 WALL 00 I .0 04 PW (3) 2X4 #2 SPF 11 81-81 FLkT C�G. W/ (3)16d �1 � - TOENAILS@ BASE IT R� 12 *42" SLOPING 11 9 ;t 8 u- FLEX V 8'-8" FLAT CLG. CARPET 1 \_(2) #5'S C� X W 6 0 0 HALF WALL/ 10 OPAD e. FLOOR G.T. -3 9 14 7� 8 !UP.46V I , I G S3 lr�ll I TYP @ 2 STORY N� 4) C ;LX C0 11111 11111771W=Lj1I71IIiRI11_ 1111111111111 4) TYP @ 2 STORY (3) 2X4 #2 SPF W/ (3) 16d � TOENAILS @ BASE @ HEADER SCHEDULE MARK HEADER SIZE REMARKS (2) - 2X6 #2 SYP W/ 1/2" FLITCH PLATE (2) - 2X8 #2 SYP W/ 1/2" FLITCH PLATE (2) - 2X1 0 #2 SYP W/ 1/2" FLITCH PLATE (2) - 2X12 #2 SYP W1 1/2" FLITCH PLATE (2) - 13/4" X 11 1/4 LVL 2.OE Fb=2950 (2) - 13/4" X 9 1/4" LVL 2.OE Fb=2950 (2) - 1 3/4" X 16" LVL 2.OE Fb=2950 (2) - 1 3/4' X 7 1/4" LVL 2.OE Fb=2950 R.A.G. (2) - 2X4 #2 SYP W/ 1/2' Follow Q/S4. See Plan for FLITCH PLATE Bearing Wall Call Out When Straps are Required VERIFY W/ PLAN CORRECT LENGTH OF HEADER REQUIRED SEE PLAN FOR DETAIL CALL OUT FOR CONNECTIONS AIND REQUIRED STUDS WINDOW SCHEDULE SIZE R.O. CMU (Flange) R.O. FRAME (Fin) TYPE 12 20 X 26 18JX25j S.H. 13 20 X 38 j 18 j X 37 1 S.H. 14 20 X 501 18 4 X 50 S.H. 15 20 X 63 18JX 624 S.H., 16 20 X 72 184 X 714 S.H. J32 27 1/4 X 26 26 X 25 j S.H. 433 27 1/4 X 38J N/A SH j 34 27 4 X 501 N/A S.H. J33 N/A 26 x 37 1 S.H. j 34 N/A 26 x 50 S.H. 435 27JX63 26 X 62 1/2 S.H. J36 27JX72 26 X 71 1/2 S.H. 22 37JX26 36 j X 25 1/2 S.H. 23 37JX38i 36 j X 37 3/4 S.H. 24 37JX501 36 4 X 50 S.H. 25 37 j X 63 36 4 X 62 1/2 S.H. 26 37 j X 72 36 j X 71 1/2 S.H. DOUBLE 2 WIDE 75"TALL 73 j WIDE S.H. 32 54 X 26 52JX254 S.H. 33 54 X 38J 52JX 371 S.H. 34 54 X 501 52 j X 50 S.H. 35 54 X 63 52JX 62J S.H. 36 54 X 72 52 j X 714 S.H. 39X59 40 X 59 N/A S.H. DOUBLE 39X59 79 X 59 N/A S.H. General notes R302.5 Dwelling/Garage Open ing/Penetration Protection. • Openings from a private garage directly into a room used for sleeping purposes shall not be permitted. Door between garage and residence shall be equipped with solid doors not less than 13/8" in thickness, solid or honeycomb -core steel doors not less than 13/8" thick, or 20-minute fire -rated doors. • Duct Penetration. Ducts in the garage and ducts penetrating the walls or ceilings separating the dwelling from the garage shall be constructed of a minimum No. 26 gage (0.48 mm) sheet steel, 1 inch minimum rigid nonmetallic class 0 or classl duct board, or other approved material and shall have no openings into the garage. • Other penetrations shall be protected as required by section R302.1 1, Item 4. R302.6 Dwelling/Garage Fire Separation. The garage shall be separated from the dwelling as per the following: • From the Residence & Attics - Not Less than 1/2" Gyp. Bd. or equivalent applied to garage side. • From Habitable Rooms Above Garage - Not Less than 5/8" Type-X Gyp. Bd. or equivalent. • Structure(s) Supporting Floor/Ceiling Assemblies - Not Less than 1/2" Gyp. Bd. or equivalent. • Garages Located Less Than 3 Feet From Dwelling On The Same Lot - Not Less than 1/2" Gyp. Bd. or equivalent applied to the interior side of exterior walls that are within this area. R312.2.1 Window Sills. In dwelling units, where the opening of an operable window is located more than 72 inches above the finished grade or surface below, the lowest part of the clear opening of the window shall be a minimum of 24 inches above the finished floor of the room in which the window is located.Operable sections of windows shall not permit openings that allow a 4-inch-diameter sphere where such openings are located within 24 inches of the finished floor. ap r rive w m ng oo, s, ec ion All doors and windows providing direct access from the home to the pool shall be equipped with an exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 db a at 10 feet. Any deactivation switch shall be located at least 54 inches above the threshold of the access. Separate alarms are not required for each door or window if sensors wired to a central alarm sound when contact is broken at any opening. M 1507.2 Recirculation of Air. Exhaust air form Bathrooms and toilet rooms shall not be recirculated within a residence or to another dwelling unit and shall be exhausted directly to the outdoors. Exhaust air from bathrooms and toilet rooms shall not discharge into an attic, crawl space or other areas inside the building. GAS APPLIANCES G.C. to verify location of gas riser before commencement of work. see Sht. SN1 for installation detail. Where gas water heaters are installed. Water heaters shall be installed a min. of 18" above fir. per FBCR G2408.2. Except where appliances that are listed as flammable vapor ignition resistant. OPENING PRESSURES ENCLOSED - EXPOSURE "C" rA-) \-Cl� +25.6 -27.8 +25.6 / -34.3 +24.5 -26.7 +24.5 / -31.9 +23.0 -25.2 +23.0 / -28.9 SEE SN SHEET Ku SEE SN SHEET MPH NOTE: WIND SPEED INDICATED ABOVE IS AN "ULTIMATE" WIND SPEED. THE WIND PRESSURES LISTED ABOVE ARE ALLOWABLE PRESSURES WALL LEGEND [111111111111111 TYP. 2x FRAME WALL BEARING WALL INTERIOR BEARING WALLS NOTED "FLOOR BEARING ONLY" ARE FLOOR SYSTEM SUPPORTING ONLY AND REQUIRES NO UPLIFT CONNECTORS TO FLOOR SYSTEM AREA TABULATION "All' 1 ST FLOOR LIVING AREA 1093 2ND FLOOR LIVING AREA 1491 LIVING TOTAL 2584 GARAGE 427 FRONT ENTRY 35 TOTALAREA 3046 0 INSULATION REQ. LOCATION I R-VALUE / TYPE EXT CONC WALL EXT FRAME 2 x 4 EXT FRAME 2 x 6 CONDITIONED CEILING R-4.1 HIGH PERM R-1 1/R-1 3 KRAFT FACED R-19 KRAFT FACED R-30 BLOWN -IN (INSTALL BAFFELS AT EAVE) GARAGE SEPARATION I R-11/R-13 KRAFT FACED (GARAGE / LIVING) W) 0 z Cf) -8 z z z C U') (D Q) C-n 4--J LU U 0 LU E 0 -(D- V) ro .20 M r.- C14 0 E 8 aim MM -S M 0.2 c, ILL 02- 0 0 < A I low. N.c 11`c 'f iecl 0 z E Lu�: ZW v M . M V. N ppsslo To the bes belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code Sth Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. z r4 0 (V N 1-4 4-J C:) 0 *5 C:) V) a Lr) CL z 0 W - Ln U_ z < CL 00 Z E Z§ Uj 0 _j CD W %D 'Ir CL Ln cr o z W Lr) 0 LL 0 U C/) r4 Z 1V 9 z 11.1 Ln 4 Lli X < X < z 00 rn lf�l Z z 5 t-u ILLI 0 r_1 CL U1) AS NOTED -SCALE DATE 2/24/2014 TECH: MJAMES VERSION No' 10 SHEET NO. 1.0 <�> 4) TYP @ CORNERS U.N.O. R&S EGRESS N r cc I I I 7n"F TYP @ 2 STORY I W.I.C. I BEDROOM 4 _.P — &D 3 D2 8'-0" FLAT CLG. 8 8'-0" FLAT CLG. BEDROOM 3 Oi b CARPET py a OP 8'-0" FLAT CLG luorul CAR PET 4) Ix ROOF G.T. TIL� 04 — 7CT 13'-0" C14 6-5�2" 2'-4" 4'-21" 60 TYP @ 2 STORY �6 00 4068 B.F. C4,4 M T-E�"' ED z LL =Lu LLJ U) 0 z 4068 B.F. C14 SHOWER FIBERGLA,' 00 (01 (0 — CD ;o 04 2668 - — — — — — ------------ R&S SURI�OUIN ioc C� Lr. 4'-0" ;0, 6'-10f7___/7j rj 5-4 2 41 13'-71" < BEDROOM 2 N 12418 uj 8'-0" FLAT CLG. 9 E LAT CL IG -a 1 �a- r 3-5 z,—.2 2—,, 1 ATTIC I LL: CARPET --------- b 8'-0`F 1? 10 L 6_C_-G nt i col T TI AT 0:1 LID 60 a. Lu =Lu _E 3 usp �2 C 4 Sim. W/ (5) STUDS '-81 3 2" :3-9-2 2'-4" 6-110 V-4" 2'-6" 16'-8" LO 4--0j- T-71" 14-4- OWNER'S SUITE R.A.G. 1 15 LOFT r- <8> 4) 1: U) 2 cuj) 0? 8'0" FLAT CLG. CARPET 8'-0" FLAT CLG. CARPET H02 14 1 3 LO ROOF G.T. --Zrx�= (D Lu H __ I - - — — — — — — < X CO ---=I 11 z 10 U. F, TYP @ 2 STORY TYP @ 2 STORY 1 1 2 4 D bi 16 S6 (i) HEADER SCHEDULE MARK HEADER SIZE REMARKS (2) - 2X6 #2 SYP W/ 1/2" FLITCH PLATE (2) - 2X8 #2 SYP W/ 1/2" FLITCH PLATE <@>(2) - 2X1 0 #2 SYP W/ 112- FLITCH PLATE (2) - 2X12 #2 SYP W/ 1/2" FLITCH PLATE <e>(2) - 1 3/4" X 11 1/4 LVIL 2.OE Fb=2950 - 13/4' X 9 1/4- <@>(2) LVL 2.OE Fb=2950 <e>(2) - 1 3/4" X 16" LVL 2.OE Fb=2950 (2) - 13/4" X 7 1/4" LVL 2.OE Fb=2950 (2) - 2X4 #2 SYP W/ 1/2" Follow Q/S4. See Plan for R.A.G. FILITCH PLATE Bearing Wall Call Out When Straps are Required VERIFY W/ PLAN CORRECT LENGTH OF HEADER REQUIRED SEE PLAN FOR DETAIL CALL OUT FOR CONNECTIONS AND REQUIRED STUDS 140C EXTERIOR 2ND FLOOR BEARING WALL SCHEDULE HEIGHT STUD SPECIES SPACING SPIF #2 8'-0" 2x4 SYP #2 16" O.C. SPF #2 91-011 2x4 SYP #2 16" O.C. SPF #2 >99-011 2x6 SYP #2 16" O.C. * IF WITHIN 4FT OF END ZONE, USE DOUBLE STUDS AT CORNERS ** WALL SHEATHING 15/32" EXPOSURE 1 OR EQUIVALENT SEE C/S6 WALL SCHEDULE WINDOW SCHEDULE SIZE R.O. CMU (Flange) R.O. FRAME (Fin) TYPE 12 20X26 18JX 254 S.H. 13 20 X 38J 184X 37J S.H. 14 20 X 501 18 X 50 H. 15 20 X 63 18JX62j S.H. 16 20 X 72 18JX 714 S.H. J32 27 1/4 X 26 26 X 25 j S.H. j 33 27 1/4 X 38 j N/A S.H. j 34 27 j X 501 N/A S.H. 33 N/A 26 x 37 S.H, j 34 N/A 26 x 50 S.H. 435 27 j X 63 26 X 62 1/2 S.H. 436 27 j X 72 26 X 71 1/2 S.H. 22 37 j X 26 36 j X 25 1/2 S.H. 23 37 J X 38 j 36 4 X 37 3/4 S.H. 24 37 j X 50 1 36 j X 50 S.H. 25 37JX63 36 j X 62 1/2 S.H. 26 37 j X 72 36 j X 71 1/2 S.H. DOUBLE 2 WIDE 75" TALL 73JWIDE S.H. 32 54 X 26 52 j X 254 S.H. 33 54 X 38 j 524X 37J S.H. 34 54 X 501 52JX 50 S.H. 35 54 X 63 52JX 62J S.H. 36 54 X 72 52JX 71 j S.H. 39X59 40 X 59 N/A S.H. DOUBLE 39Xii] 79 X 59 N/A S.H. General notes R302.5 Dwelling/Garage Opening/Penetration Protection. • Openings from a private garage directly into a room used for sleeping purposes shall not be permitted. Door between garage and residence shall be equipped with solid doors not less than 13/8" in thickness, solid or honeycomb -core steel doors not less than 13/8" thick, or 20-minute fire -rated doors. • Duct Penetration. Ducts in the garage and ducts penetrating the walls or ceilings separating the dwelling from the garage shall be constructed of a minimum No. 26 gage (0.48 mm) sheet steel, 1 inch minimum rigid nonmetallic class 0 or classl duct board, or other approved material and shall have no openings into the garage. • Other penetrations shall be protected as required by section R302.1 1. Item 4. R302.6 Dwelling/Garage Fire Separation. The garage shall be separated from the dwelling as per the following: • From the Residence & Attics - Not Less than 1/2" Gyp. Bd. or equivalent applied to garage side. • From Habitable Rooms Above Garage - Not Less than 5/8" Type-X Gyp. Bd. or equivalent. • Structure(s) Supporting Floor/Ceiling Assemblies - Not Less than 1/2" Gyp. Bd. or equivalent. • Garages Located Less Than 3 Feet From Dwelling On The Same Lot - Not Less than 1/2" Gyp. Bd. or equivalent applied to the interior side of exterior walls that are within this area. R312.2.1 Window Sills. In dwelling units, where the opening of an operable window is located more than 72 inches above the finished grade or surface below, the lowest part of the clear opening of the window shall be a minimum of 24 inches above the finished floor of the room in which the window is located.Operable sections of windows shall not permit openings that allow a 4-inch-diameter sphere where such openings are located within 24 inches of the finished floor. Chapter 45 Private Swiming Pools, Section R4501.17.1.9 All doors and windows providing direct access from the home to the pool shall be equipped with an exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 db a at 10 t. Any deactivation switch shall be located at least 54 inches above the threshold of the access. Separate alarms are not required for each door or window if sensors wired to a central alarm sound when contact is broken at any opening. M 1507.2 Recirculation of Air. Exhaust air form Bathrooms and toilet rooms shall not be recirculated within a residence or to another dwelling unit and shall be exhausted directly to the outdoors. Exhaust air from bathrooms and toilet rooms shall not discharge into an attic, crawl space or other areas inside the building. GAS APPLIANCES G.C. to verify location of gas riser before commencement of work. see Sht. SN1 for installation detail. Where gas water heaters are installed. Water heaters shall be installed a min. of 18" above fir. per FBCR G2408.2. Except where appliances that are listed as flammable vapor ignition resistant, OPENING PRESSURES ENCLOSED - EXPOSURE "C" +25.6 -27.8 +25.6 / -34.3 +24.5 -26.7 +24.5 / -31.9 +23.0 -25.2 +23.0 / -28.9 SEE SN SHEET SEE SN SHEET 140 MPH NOTE: WIND SPEED INDICATED ABOVE IS AN "ULTIMATE" WIND SPEED. THE WIND PRESSURES LISTED ABOVE ARE ALLOWABLE PRESSURES WALLLEGEND TYP. 2x FRAME WALL BEARING WALL INTERIOR BEARING WALLS NOTED "FLOOR BEARING ONLY" ARE FLOOR SYSTEM SUPPORTING ONLY AND REQUIRES NO UPLIFT CONNECTORS TO FLOOR SYSTEM AREA TABULATION "All' IIST FLOOR LIVING AREA 1093 2ND FLOOR LIVING AREA 1491 LIVING TOTAL 2584 GARAGE 427 FRONT ENTRY 35 TOTALAREA 3046 0 INSULATION REQ. LOCATION R-VALUE / TYPE EXT CONIC WALL R-4.1 HIGH PERM EXT FRAME 2 x 4 R-1 1 /R-1 3 KRAFT FACED EXT FRAME 2 x 6 R-19 KRAFT FACED CONDITIONED CEILING R-30 BLOWN -IN (INSTALL BAFFELS AT EAVE) GARAGE SEPARATION (GARAGE / LIVING) R-11/13-13 KRAFTFACED 0 LOU Z co (A 0 111) (—J3 4—J LL, (D(10 0 U 0 LU Ln =3 E 0 go I 00 Fn r, LU 8 MINE C14 (D CI) M 0 .2 c, 0� LL S8 0 M U) R E 0 LO :S Ci -A ED. N-C-H 1) C MIS, SE t LU W W C4 gz M U0 & To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code Sth Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. C:) C:l` z rl�j 0 CU r-, 9�0 U.) C) 4 U*) M Ln �� r- 0 cu U-) O� U 00 < E Z�: M z C) F- WLU _j 0 ce 0 z 1z" �p� > Ln 0 z Q� L0 0 __j UL 0 1 0 r,4 L) CM 11 0 U_ i--,o 6 6 0! pu < < z a LL, z LU L0 UJI Z < z t-u 00 M II.D 0 Ln z ILIJ z SCALE AS NOTED DATE 2/24/2014 TECH: MJAMES VERSION NO' 10 SHEEr NO. MIN, (3) 2x STUDS REQ'D @ END OF LANDING BELOW HDR. BEAM. STANDARD (3) 2x12 STRINGERS w/ SIMPSON A35/USP MP34 CLIP TO FLOOR SYSTEM OR LANDING FRAMING (2) 2x HDR. REQ'D @ END OF LANDING FOR STRINGERS TO CONNECT TO MIRROR 0 LW zM Z(o z Ci- Z U-1 (D U 0 LU E Ln 0 C) C14 I.— E 8 080 C) CO21" 0 IT <0 ED. 0 &1 9 :r- 8t, -s 10 r,3-A4 L ;�g /) C IL M *A 9 r) �Z, CP F LO.. . ......... To the best of the Engineer's knowledge, Information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code Sth Edition (2014) Residential. Engineer's signature and seal Is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. C) z 0(i) �--4 4-J C:) U0 1 5 t 0 1:2� LA M cc::)) re) N M In z tn tN Q) — Lr) < L_ U_ CL Ce >, CV) U -4 z < E 00 z z WLU _J CD 9z 91 Z z if 08,0 NOw U) "pi i I < Lii M z 0 Ln - 2: r-4 Lu 0 U 0 0 Z z UJI Ln LU UJ 2: 00 < M z t.0 Z LI) z t_U Cal LLJ 0 r�% :5 r_1 r-11 SCALE AS NOTED DATE 2/24/2014 TECH: MJAMES VERSION NO' 10 SHEET NO. 2.0 OWNER'S BATH 07 I r r0m I I KITCHEN ISLAND PLY SHEATHING OVER OWNER'S BATH 07 I r r0m I I KITCHEN ISLAND PLY SHEATHING OVER LANDING ATTACHED PER GENERALFLOOR CONSTRUCTION NOTES 2x8 #2 SYP JOISTS @ LANDING @ 16"O.C. w/ SIMPSON A35/USP MP34 OR LUS26 HANGER ON EA. SIDE MASONRY OR WOOD WALL, SEE PLAN 2x8 #2 SYP (P.T. IF MANSONRY z < WALL) CONT LEDGER w/ (3) 16d NAILS @ 16" O.C. MAX. TO EA. _J STUD. ((2) 1/4"X3 1/2" TITENS @ 16" O.C. MAX. FOR MASONRY WALL) GENERAL LANDING FRAMING INFO. SCALE: N.T.S. V-101" MAX LANDING LENGTH Q 2x8 #2 SYP JOISTS @ LANDING @ 16" O.C. w/ SIMPSON A35 CLIP OR LUS26 HANGER TO LEDGER 2x12 HDR. w/ (3) 2x STUDS AT EA. END FOR BEARING--\ STANDARD (3) 2X12 STRINGERS W/ SIMPSON A35 CLIP TO HDR.__\ 1x TREADS (TYP-) CONT. HANDRAIL C ----THRUST BLOCK SECURED TO SLAB w/ 1/4"X3 1/2" TAPCONS @ 16" O.C. KITCHEN PLYWOOD @ LANDING 2x8 LEDGER #2 SYP W/ (3) 16d NAILS TO STUD @ 16" O.C. 00 8'- BATH 2 PPF=-F-N(' , Fl OnP.IOMT W/ (9) KITCHEN INTERIOR ELEVATIONS STAIR CALCUTIONS: TOTAL RISE - 10' -0 3/4" (16) RISERS AT 7 9/16- 10"TREADS w/ 1" NOSING to conform to Residential section R311.7 SCALE: 1/2"=V-0" Riser height: The maximum riser height shall be 7Y4". The greatest riser height within any flight of stairs shall not exceed the smallest by more than %". Tread depth. The minimum tread depth shall be 10". The greatest tread depth within any flight of stairs shall not exceed the smallest by more than Y8". The radius of the nosing shall be no greater that 9/16". Solid riser nosings shall not be less than 3/4" but not more than %". The greatest nosing projection shall not exceed the smallest by more than X". Beveling of nosings shall not exceed y2" Handralls shall be provided on at least one side of each continuous run of treads or flight with four or more risers. Handrail height, measured vertically from the sloped plane adjoining the tread nosing, or finish surface of ramp slope, shall be not less than 34" and not more than 38". Handrails adjacent to a wall shall have a space of not less than %"between the wall and the handrails. Handrails with a circular cross section shall have an outside diameter of at least 1 1/4" and not greater than 2" or provide equivalent graspavility in compliance with FBC 5th Edition (2014) Residential Section R311.7.8.3. Guards. Guards shall be located along open -sided walking surfaces, including stairs, ramps and landings, that are located more then 30" and shall be not less than 36". Required guards shall not have openings from the walking surface to the required guard height which allow passage of a sphere 4" in diameter. Winders. Winder treads shall have a minimum tread depth of 6" at the narrow end and shall have a minimum tread depth of 10" at the intersections with the walkline (112" from the narrower side). 7 Under -Stair Protection. 3ed accessible space under a stairway shall be protected with Y." gyp. SCALE: 1/2"=V-0" I SEE PLAN FOR LANDING DEPTH I 00 T.O.P. HGT. 11" x 12" SMOOTH TEXTURED TRIM / BAND 2nd FIN. FLR. T.O.M. HDR HGT. F.FL. 12 51 12 Z:::::� 5 L L1-::1 LE _LL1 I r,`� DECORATIVE SHUTTER FRONT ELEVATION - Al. SCALE: 1/4"=V-0" LEFT ELEVATION T.O.P. — — — — — — — HDR HGT,, V_ _I 2nd FIN. FLR. T.O.M. HDR HGT, F.FL. - Al SCALE: 1/4"=V-0" 19 r General Notes ROOF CRITERIA: 0 12" OVERHANG U.N.O. 0 PLUMB CUT FASCIA ROOF * PITCH PER ELEVATION **G.C. VERIFY ROOF PITCH" ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE CONTRACTORS RESPONSIBILITY TO VERIFY ROOF SLOPE REQUIREMENTS WITH TRUSS MANUFACTURER. "ELECTRICAL SPECIFICATION NOTES" ELECTRICAL CONTRACTOR MUST VERIFY WITH THE SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT FIXTURES SHOWN ARE FOR LOCATION PURPOSES. Exterior Covering R703.6 Exterior plaster. Installation of these materials shall be in compliance with ASTM C 926 and ASTM C 1063. R703.6.1 Lath. All Lath and lath attachments shall be of corrosion -resistant materials. Attached per ASTM C 1063. R703.6.2 Plaster. Plastering w/ portland cement plaster shall be not less than three coats when applied over metal lath or w1re lath and shall be not less than two coats when applied over masonry, concrete. R703.6.3 Water-Resisitive Barriers. Water-resisitive barriers shall be installed where cement plaster (stucco) is to be applied over wood -based sheathing, shall include a water -resistive vapor -permeable barrier'. The individual layers shall be installed Independently such that each layer provides a separate continuous plane and any flashing intended to drain to the water-resIstive barrier is directed between the layers. The barriers shall consist of one of the following. 1. Two layers of an approved water resistant barrier material in accordance with R703.2. 2. One layer of an approved water -resistive barrier (paperbacked stucco lath) over an approved synthetic house wrap. R703.8 Flashing. Approved corrosion -resistant flashing shall be applied shingle -fashion in a manner to prevent entry of water into the wall cavity or penetration of water to the building structural framing components. Flashing shall be Installed at the following locations. • Exterior winclow/cloor openings. • Intersecfion of chimneys or other masonry contructions with frame walls. • Under and at the ends of masonry, wood or metal copings; and sills. • Continuously above all projecting wood trim. 0, Where exterior porches, decks or stairs attach to a wall or floor assembly of wood-fra me construction. • At wall and roof intersections • At Built-in gutters. Attic Ventilation Attic Ventilation to be in compliance with the Florida Building Code 5th Edition (2014) Residential R806. The Minimum net free ventilating area shall be 1/150 of the area of the vented space. The ventilating area may be reduced to 1/300 provided that at least 40% but no more than 50% of the required ventilation is provided in the upper portion of the space to be ventilated.Upper ventilators shall be located no more than 3 feet (measured vertically) below the ridge or highest point of the space, with the balance of the required ventilation provided by eave or cornice vents. "CALCULATIONS BASED ON THE FOLLOWING VALUES, SEE ROOF PLAN - (Values to be verified with Manufacturer Specifications) • RIDGE VENTS 15 SQ. IN. OF NET FREE AREA / LINEAR FT. • OFF -RIDGE VENTS 138 SO. IN. OF NET FREE AREA / UNIT • SOFFIT VENTS 7 SQ. IN. OF NET FREE AREA / SQ. FT. • O'HAGIN WEATHERMASTER (Shingle Roof) - 72 SO. IN. OF NET FREE AREA/ FT. (Sq. Ft. Soffit Needed) x 7 - (Sq. In, Needed) / 72 = Amount of O'Hagin Vents Needed • LOMANCO DECK -Al R (Shingle Rool) - 9 SO. IN. OF NET FREE AREA/ FT, Formula: (Sq. Ft. SoMt Needed) x 7 = (Sq. In. Needed) / 9 = (Unear Ft. of Dock -Air Needa4 • O'HAGIN (Tile Roof) - 86.25 SO. IN. OF NET FREE AREA/ VENT "Formula: (Sq. Ft. SoMt Needed) x 7 = (Sq. In. Needed) / 86.25 = Amount of O'Hagin Vents Needed 0 (D ` z 0 (o 13 Z z CL U) Cz L/) (D Z (1) C_X3 +_J LU 0 LU 0f 120 E 0 C) LU E 8 04 4) Cf) 0) co c: Cam 2 P, R 0.2" :3z Z ILL CD = -Go 0 .19 < tom Lo A I Do N1\\X1 0 WX SE C4 W W U, W rn C) LLf3, L dql 9 Ic lot. To the best of the Engineer's knowledge, Information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code Sth Edition (2014) Residential. Engineer's signature and seal Is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. CD z r-4 0 v N b-4 C) V) > M Ln < (A ON CL LL Y-4 z C1. 00 Z3: E z LLJ (=) _J 0 W Z,<L rz j U) .4 � 0& ,Z 0 0 CC uJ � I UJI _J LU Ln U-i z N Lr) 0 0 r-4 M U < F_ 0 CC P6 ILL �q a:J Lu� ce z z UJI Ln CY 2 T-4 I UJ z 211 LU F; 00 ro Z z 0 N % LU X: J < rn T-1 0- SCALE AS NOTED DATE 2/24/2014 TECH: MJAMES VERSION NO - 10 SHEET NO. 3.1 lco 00 A Mir co bo loo I 00 - A MI-V bo 12 5 F�:� T.O.P. HDR HGT. 12 5 2nd FIN FLR. CJ / WEE� w7tii�E�Pll T.O.M. 12 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - HDR HGT. - - - - - - - - - - - - - - - - — - - - - - - - - - - - - - - - - - - CENTERED ON DOOR TEXTURED—J 23S CEMENTICIOUS FINISH ON C.M.U. (TYP.) F.FL. T.O.P HDR HGT. .......................... 2nd FIN. FLR k- T.O.M - ------------------ HDR HGT F.FL 9'RIDGE VENT 12 5 F::� REAR ELEVATION - Al SCALE: 1/4"=V-0" RIGHT ELEVATION - Al SCALE: 1/4"=V-0" General Notes ROOF CRITERIA: 12" OVERHANG U.N.O. PLUMB CUT FASCIA ROOF PITCH PER ELEVATION .G.C. VERIFY ROOF PITCH" ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE CONTRACTORS RESPONSIBILITY TO VERIFY ROOF SLOPE REQUIREMENTS WITH TRUSS MANUFACTURER. "ELECTRICAL SPECIFICATION NOTES" ELECTRICAL CONTRACTOR MUST VERIFY WITH THE SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT FIXTURES SHOWN ARE FOR LOCATION PURPOSES. Exterior Covering R703.6 Exterior plaster. Installation of these materials shall be In compliance with ASTM C 926 and ASTM C 1063. R703.6.1 Lath. All Lath and lath attachments shall be of corrosion -resistant materials. Attached per ASTIM C 1063. R703.6.2 Plaster. Plastering w/ portland cement plaster shall be not less than three coats when applied over metal lath or wire lath and shall be not less than two coats when applied over masonry, concrete. R703.6.3 Water-Resisitive Barriers. Water-resisitive barriers shall be installed where cement plaster (stucco) is to be applied over wood -based sheathing, shall include a water -resistive vapor -permeable barrier. The Individual layers shall be installed independently such that each layer provides a separate continuous plane and any flashing intended to drain to the water -resistive barrier Is directed between the layers. The barriers shall consist of one of the following. 1. Two layers of an approved water resistant barrier material in pprmo stucco lath) over an approved synthetic house wrap. R703.8 Flashing. Approved corrosion -resistant flashing shall be applied shingle -fashion in a manner to prevent entry of water into the wall cavity or penetration of water to the building structural framing components. Flashing shall be installed at the following locations. 6 Exterior winclow/cloor openings. 4, Intersection of chimneys or other masonry contructions with frame walls. 41 Under and at the ends of masonry, wood or metal copings and sills. Continuously above all projecting wood trim. Where exterior porches, decks or stairs attach to a wall or floor assembly of wood -frame construction. At wall and roof intersections At Built-in gutters. Attic Ventilation Attic Ventilation to be in compliance with the Florida Building Code 5th Edition (2014) Residential R806. The Minimum net free ventilating area shall be 1/150 of the area of the vented space. The ventilating area may be reduced to 1/300 provided that at least 40% but no more than 50% of the required ventilation is provided in the upper portion of the space to be ventilated.Upper ventilators shall be located no more than 3 feet (measured vertically) below the ridge or highest point of the space, with the balance of the required Ventilation provided by eave or cornice vents. -CALCULATIONS BASED ON THE FOLLOWING VALUES, SEE ROOF PLAN - (Values to be verified with Manufacturer Specifications) • RIDGE VENTS 15 SO. IN. OF NET FREE AREA / LINEAR FT. • OFF -RIDGE VENTS 138 SQ. IN, OF NET FREE AREA / UNIT • SOFFIT VENTS 7 SO. IN. OF NET FREE AREA / SQ. FT. • O'HAGIN WEATHERMASTER (Shingle Roof) - 72 SO. IN. OF NET FREE AREA/ FT. (Sq. Ft. Soffit Needed) x 7 - (Sq. In. Needed) / 72 = Amount of O'Hagin Vents Needed • LOMANCO DECK -AIR (Shingle Roo� - 9 SO. IN. OF NET FREE AREA / FT. -Formula: (Sq. Ft. Soffit Needed) x 7 = (Sq. In. Needed) / 9 = (Unear Ft. of Deek-Air Needed) 9 O'HAGIN (Tile R000 - 86.25 SO. IN. OF NET FREE AREA/ VENT '*Formula: (Sq, Ft. Soffit Needed) x 7 - (Sq. In. Needed) / 86.25 = Amount of O'Hagin Vents Needed (D LO z M z < 1 ZL/) 0 Q) C-n Ui C) U 0 U_J E 0 00 04 (n LU E 8 0) r_ M Cl) T:SM, 0 _Q , ai; C)% U. OM < 0 CL < ci A ab I 41 0 \N S !a! V. 0_v at:a — r LU LLJ 0 v 0) < E S S I To the best ofthe Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code 5th Edition (2014) Residential. Engineer's signature and seal Is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. Z (N4 0 Q) N 0-4 4-d V) * S ro CD C:) Lr) < in z W 0 W Ln L_ Z: 0-N Cn ce U z < CL OC) . E Z3: M Z F- WLu c=) _J 0 %D LL, z g U) o Or- Rw 99, 01__: LU _J LU �i 0 U Lr) LU M z Ln 0 U < LU �U_ 11 9 F- f'4 IZIC < Z L11 z LU Ln LJ L-OL Lij < < z ce uJ 00 rn Ln Z Z 00 0 r�% :5 LU rn T_q 0- U) SCALE AS NOTED DATE 2/24/2014 TECH: MJAMES VERSION No' 10 SHEET NO. 3.2 2„ 1" iv = c� iv 2" iy 1' VARIES *NOTE: FOAM TO BE USED ONLY WHEN = REQUIRED BY COMMUNITY SPECS. IF NOT, 1" 2" OPENING VARIES 2" �2"�- DETAIL TO BE 'r-'I BUILT W/ STUCCO. EDGE OF OPENING 1'-10" _ ^� N O Ch c i N 34" 1„ 1„ 1" 14 1" RADIUS 31/2" RADIUS 3/4" RADIUS 1/2" RADIUS 1" 2j" 1 1/2" RADIUS 2 1/2" RADIUS 4" 1/2" RADIUS 1'-5 " VARIES VARIES VARIES 1 " VARIES BASE M HIV v 'N '-N LO z _ • 31" � oily r T. 11. 4 4j„ � �� �� 3"" SIN ill :34 2„ VARIES 12 • 3„ io • *NOTE: FOAM TO BE USED ONLY WHEN REQUIRED BY COMMUNITY SPECS. IF NOT, 1" DETAIL TO BE BUILT W/ STUCCO. VARIES OPENING VARIES 2„ 2„ EDGE OF OPENING 2" 8" 2" 1'-6" 1" 1'4" Q N 1" - ' '-v 1, is 21" s a I� N O , I s c = � = N 101, 101, 6" "' z b" gib" 6" 2„ W > 1-1/2" THICK W 1-1/2" THICK N4'-�'t ;13 �LN _ 00 IN w 1-1/2" THICK • 2'-4" 1'-10"„ 1'-4" 3„ • �„ N 2" - — 521„ 1,-5" " 51„ 4 I �1"p o /^ 2' 4q" : VARIES VARIES _-._ N i--------- CV I = I I L I C to Rsry CD ' 6" J� 4" I I _ = N 4d : VARIES VARIES :— KEYSTONE F11 0 = 00 i r- KEYSTONE F11 OPTIONAL OPTIONAL 3" 4" GARAGE DR. OPENING 4" LT' 4 ' 4" WINDOW OPENING 4"" NOTE:INSTALL OVER STONE, TYP. • FIN. TO HAVE TRADITIONAL LOOK & SMOOTH FINISH • FOAM/ EPS MATERIAL IS ACCEPTED — VARIES f2" 00 1" e NOTE: • FIN. TO HAVE TRADITIONAL LOOK & SMOOTH FINISH • FOAM/ EPS MATERIAL IS ACCEPTED T-8" 4" T-0" 4" 10„ 1,4„ 10„ `7 o , "r6 14 1'-64" 14. 12" 0 tD N -- _ <V 5j" V-11" 5j" _ 1,4„ (V z N -------- ' GENERAL NOTES: • 1.5 LBS DENSITY STYROFOAM • ACRYLIC SAND FINISH H 0.10 Z t> — o 13 Z Q J a U) z Cn U' Q) C w U 0 w � (n = ro ~ o o 0 f- U m� N Cn w —8 WW~E C M M �LLN Ooo di Y fi LLo coOD 0 n a� Qrn Qo A , B D. N•cunc p N cqtz1 tA Z I o p OND g J Z �I cqW= o-jJ /y LL N L r7 W Fl V%Va�ao, 0 w,L d W Z A IL t7H�g�° Z ad �NarNi Cr m d W U U � o U0 1— ❑❑ To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code Sth Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. 0 0 Z C4 O a1) N t/) M C M Q � M Ln rLn- Q S.- aU� - ono Z W Jo� t0 d' z d U J U0 Z00U Q �® L U z Ln Cr o N 0 LU XY,� 0> r w 1 .. � r4 N rS Z Z J ^ Ln Lij a rl Uj Q Z W M � m � z t _ rn O ,--I _] 0- v7 SCALE : AS NOTED DATE : 2/24/2014 TECH: MJAM ES VERSION NO. 10 SHEET NO. F1 ELECTRICAL SPECIFICATION NOTES: ELECTRICAL CONTRACTOR MUST VERIFY WITH THE SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT FIXTURES SHOWN ARE FOR LOCATION PURPOSES. 200A INDOOR PANEL NEMA I 2DO AMP #14 copper to lights& outlets 012 copper to 20 amp cirts #10.2 copper to WH #10-3 copper to Dryer 200amp Y2'Oor4'0'ER"u 150 amp Di nne POWER CO. FEED _Tct INTERSYSTEM 4 Bare Cu Ground BONDING 04EGROUNDING WIRE TERMINATION PER 5P WITH CODE APPROVED NEC 08,250.94 CLAMP PER 250.50 AND 250.52 OF THE 2011 NEC. GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2011, LOCAL CODES AND THE LOCAL POWER CO. 1 . Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF (general) kitchen 44" AFF bathroom 39" AFF laundry room 36" AFF exterior waterproof 12" AFF garage general purpose 42" AFF range 2" AFF 2. All trim plates & devices to be ganged, where possible. 3. Electrical switches to be at 42" centerline above finished floor. 4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the installation & sizing of all electrical, wiring & accessories. 5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. 6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch circuits in all dwelling units per NFPA 70 and the 2011 NEC. 7. Provide Tamper Resistant Receptacles as required by the 2011 NEC, 406.11 8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station cc alarms or UL 2075, gas and vapor detector sensor, according to the installation. 9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a Nationally Recognized Testing Laboratory. 10. Keep all smoke detectors minimum of 36" from bathroom doors 11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be equipped with a monitored battery backup. 12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits is not acceptable. 13. All doors and windows providing direct access from the home to the pool shall be equipped with an exit alarm complying with UL 2017 that has a minimum sound pressure rafing of 85 DBA at 10 feet, and either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning when the door or window are opened.. 14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' if the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacles outlests shall not be required on a wall directly behind a range or sink to fulfill the requirement for an outlet every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and 18" for sinks and ranges installed in corner counters. ELECTRICAL KEY L 4=4 Vk=;1- DUPLEX CONVENIENCE OUTLET I Z±!, FF DUPLEX OUTLET ABOVE COUNTER I /-\ PE5W.P. WEATHERPROOF DUPLEX OUTLET PE�GI 'en, .F.I. GROUND FAULT INTERRUPTER DUPLEX OUTLET K;)-- HALF -SWITCHED DUPLEX OUTLET Lj(__h SPECIAL PURPOSE OUTLET DUPLEX OUTLET IN FLOOR 220 VOLT OUTLET $ WALL SWITCH $3 THREE-WAY SWITCH & . 2_4 FOUR-WAY SWITCH $R RHEOSTAT SWITCH CEILING MOUNTED LIGHT FIXTURE WALL MOUNTED LIGHT FIXTURE RECESSED LIGHT FIXTURE LIGHT FIXTURE WITH PULL CHAIN TRACK LIGHT FLOURESCENT LIGHT FIXTURE EXHAUSTFAN EXHAUST FAN/ILIGHT COMBINATION ELECTRIC DOOR OPERATOR (OPTIONAL) FCH] CHIMES (OPTIONAL) El PUSHBUTTON SWITCH (OPTIONAL) @ SMOKE DETECTOR @ SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) K TELEPHONE (OPTIONAL) [Tq TELEVISION (OPTIONAL) Fr� 2 (2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. THERMOSTAT ELECTRIC METER NMI ELECTRIC PANEL DISCONNECT SWITCH SPEAKER (OPTIONAL) ROUGH -IN FOR OPT. CEILING FAN <1/ \> CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR OPT. CEILING FAN (1) PHONE LINE, (1) DATA PORT DEDICATED RECEPTACLE FOR MICROWAVE RANGE HOOD PER SPECS WP GFI PATIO WP GFI DISC Locir A 0 VERIFY METER LOCATION WITH BUILDER H.B. GFI \WGFI %FI 1W V VERIFY LOCATION IRRIGATION OPT. ELECTRICAL PANEL F _&FI W_4T'_A - - — — — — F.F. REF. KITCHE TN. Ha\ - — — — — — — — — — — r ------- qpGFI i Li Li GFI FOR I GFI @ 44" GAR. DOOR I A. F. F. GFI J­. 2 CAR GARAGE DINING ROOM /PENDANTAS 0 L — — — — — — — — — — — — PER SPECS GFI @ 44" W H A.F.F. FOYER H.B. ROUGH -IN FOR OPT. CLG. FAN/ LIGHT PRE -WIRE 17P\'% 61 \S / =E FAMILY ROOM Yr, MY FLEX ROUGH -IN FOR OPT. CLG.FAN/ T FRY GFI MAIN FLOOR ELECTRICAL PLAN SCALE: Y4"=1'-0" to co CD Z Z __j Z V) (D Q) (-/) 4--J Lu 0 LU ZD E 0 to M Ln 00 Fa r- C) LLJ E C`4 0 M M �m -0 2 M .0 04 0 g 0 u = LL CD 00, M 0_, -.4 co Ln 0 0 < CL 0 Al .-C- 8 -D-C r CM Z ONC4 0 C', -2 .9 3 rL 0 lt LL. (0 W 7 �4.) C LL Ul < UJI CL L� Q_ ! ZU) 0) 0 . . 4 :2 Z 41W LL 0) J;� 0 LU C14 M-t 0 __j 0 0 L) L) 1,— To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code 5th Edition (2014) Residential. Engineer's signature and sea] Is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. c:l Z r14 ow �—q V) co C) p M Ln (1) ON a) — Ln < C LL CL 0� U Z < Z E %-oo Z Uj F- _j C) W 9z 11 60 Z ej r 8, L 0 0 LL Ci 0 F- 8Z Ln 0 Z L0 LLJ LU 8 0 0 LL LU 2! t-L, R P 0 :W f'4 < LL4 ar::1 Z Z UJI < Z Z 00 rn Z tu LLJ ca 0 Z r7l T-4 CL V) SCALE AS NOTED DATE 2/24/2014 TECH: MJAMES VERSION NO' 10 SHEEr NO. 4.0 ELECTRICAL SPECIFICATION NOTES: ELECTRICAL CONTRACTOR MUST VERIFY WITH THE SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT FIXTURES SHOWN ARE FOR LOCATION PURPOSES. GENERAL ELECTRICAL NOTES: Notes: unless otherwise noted, 1 . Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF (general) kitchen 44" AFF bathroom 39" AFF laundry room 36" AFF exterior waterproof 12" AFF garage general purpose 42" AFF range 2" AFF 2. All trim plates & devices to be ganged, where possible. 3. Electrical switches to be at 42" centerline above finished floor. 4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the installation & sizing of all electrical, wiring & accessories. 5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. 6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch circuits in all dwelling units per NFPA 70 and the 2011 NEC. 7. Provide Tamper Resistant Receptacles as required by the 2011 NEC, 406.11 8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and vapor detector sensor, according to the installation. 9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a Nationally Recognized Testing Laboratory. 10. Keep all smoke detectors minimum of 36" from bathroom doors 11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be equipped with a monitored battery backup. 12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits is not acceptable. 13. All doors and windows providing direct access from the home to the pool shall be equipped with an exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning when the door or window are opened.. 14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' if the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacles outlests shall not be required on a wall directly behind a range or sink to fulfill the requirement for an outlet every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and 18" for sinks and ranges installed in corner counters. I ELECTRICAL KEY I I.Z=S FEF DUPLEX CONVENIENCE OUTLET I e±, FTF DUPLEX OUTLET ABOVE COUNTER L=%_ r1V`w.P. WEATHERPROOF DUPLEX OUTLET 1.0=:)i 1­'�='G . F.I. GROUND FAULT INTERRUPTER DUPLEX OUTLET HALF -SWITCHED DUPLEX OUTLET F't�-V SPECIAL PURPOSE OUTLET 171n DUPLEX OUTLET IN FLOOR 220 VOLT OUTLET $ WALL SWITCH $3 THREE-WAY SWITCH 24 FOUR-WAY SWITCH $R RHEOSTAT SWITCH CEILING MOUNTED LIGHT FIXTURE WALL MOUNTED LIGHT FIXTURE RECESSED LIGHT FIXTURE LIGHT FIXTURE WITH PULL CHAIN TRACK LIGHT FLOURESCENT LIGHT FIXTURE EXHAUSTFAN EXHAUST FAN/LIGHT COMBINATION ELECTRIC DOOR OPERATOR (OPTIONAL) RCH CHIMES (OPTIONAL) ID PUSHBUTTON SWITCH (OPTIONAL) @ SMOKE DETECTOR SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) TELEPHONE (OPTIONAL) TELEVISION (OPTIONAL) 2 (2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. THERMOSTAT ELECTRIC METER NMI ELECTRIC PANEL _11111IF-i DISCONNECT SWITCH SPEAKER (OPTIONAL) 1> ROUGH -IN FOR OPT. CEILING FAN CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR </ OPT. CEILING FAN 69 (1) PHONE LINE, (1) DATA PORT 200A INDOOR PANEL #14 copper to lights & outlets NEMA 1 200 AMP #12 copper to 20 amp ckts #10.2 copper to WH #10-3 copper to Dryer M_A,I N 0 2/0 or 4/0 SER AJu 200 amp 150 amp IDDlaconnectl POWER CO. FEED-1 INTERSYSTEM 4 Bare Cu Ground BONDING #4 GROUNDING WIRE TERMINATION PER WITH CODE APPROVED NEC 08, 250.94 CLAMP PER 250.50 AND 250.52 OF THE 2011 NEC. Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE PROVISIONS OF THE NFPA 70 - 2011, LOCAL CODES AND THE LOCAL POWER CO. RECEPT. FC — — — — — — 51 UPPER ELECTRICAL PLAN SCALE: Y4"= V-0" 0 Z C') — 8 Z W Z CL LJO (D Z L.0 C) 0 L.Lj V) E 0 2 Ln 0 00 F0 r- C14 co ILLJ j..- E — 8 co ce) C W 1:1) E! :S cl, 0 _6 ", :3Z U LL. 00 -00 0 2 g CO CL < if) 0 'r A I N 0,11,11 1, 0! Z 'C' Z0 M 0) c=) 9: — - § — LL. cm 90) ease di L�: V CL LLj W Z 0 vct) 4m C < 2F Z LLW o) 04 To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code Sth Edition (2014) Residential. Engineer's signature and sea[ Is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seat. C) 0 Z C4 0 CU N )-4 4-J %0 U V) f0 Ln Z V) ON — Ln U_ a> " F- � CL 00 Z E Z fo Z LU LU Milli Ul Z Ln LU LU 0 0 U 0 -j LL_ 0 U. lu- R < " 0 510-1 Z UJ Z LU Ln Lij CYX ��.O� --I I 6j X Z HQ 00 < Z Z 17u 0 Z UJI Z 0 SCALE AS NOTED DATE 2/24/2014" TECH: MIAMES VERSION NO - 10 SHEET NO. 4.1 VENTED SO 40 SQ. FT. N %1MK1-rC:n Cn=ll-r An V L_ 1 11 1 L_ L..# %J %_1 I I I I _r I SQ. FT. ATTIC VENTILATION CALCULATIONS - Al ATTIC VENTILATION REQUIRED UPPER VENTILATION PROVIDED 1/150 Rule 1/300 Rule Ridge Off -Ridge (No Upper Ventilators (Must Provide Upper Ventilators) Vent Amt Amt. Req.) (Ft.) Total Ventilation ATTIC Provided SPACE SO. FT. Total SQ. SQ. FT. SQ. IN. of by Upper SQ. IN. of of vented IN. of of ventilation to SQ. IN. of SQ* IN of Ventilators ventilation soffit ventilation vented be provided Ventilation ' Ventilation (See Elev) required needed required soffit by upper needed ventilators Main 0.000000 0.000000 Floor 0 0 0 0 0 0 0.0 0.0 - ----- — 0.0 (Zone 1) Upper 9 2.000000 Floor 1535 1474 211 737 53 368 411.0 � 27 6.0 (zone 2) 1 1 1 1 135.0 **NOTE — GENERAL CONTRACTOR MUST ENSURE THAT PROPER VENTILATION IS PROVIDED AT EAVES/SOFFITS AS REQUIRED BY FBC 5th ED. RESIDENTIAL. VENTED SOFFIT LEGEND 71 IF SOFFIT IS LABELED AS "NON -VENTING" FIRE PROTECTION WILL BE INSTALLED AS REQUIRED BY SECTION R302 OF THE FBC 5th EDITION (2014) RESIDENTIAL. IF LABELED AS"VENTED", NO FIRE PROTECTION WILL BE REQUIRED, ............ VENTED SOFFIT OFFIT 'ENTED SOFFIT SQ. FT. ZONE-1 ATTIC SPACE 35 SQ. FT. ENTED SOFFIT SQ. FT. ROOF PLAN SCALE: Y4"=1'-O" General Notes ROOF CRITERIA: 41 12" OVERHANG U.N.O. 40 PLUMB CUT FASCIA ROOF 40 PITCH PER ELEVATION **G.C. VERIFY ROOF PITCH** ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE CONTRACTORS RESPONSIBILITY TO VERIFY ROOF SLOPE REQUIREMENTS WITH TRUSS MANUFACTURER. "ELECTRICAL SPECIFICATION NOTES" ELECTRICAL CONTRACTOR MUST VERIFY WITH THE SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT FIXTURES SHOWN ARE FOR LOCATION PURPOSES. Exterior Covering R703.6 Exterior plaster. Installation of these materials shall be in compliance with ASTM C 926 and ASTM C 1063. R703.6.1 Lath. All Lath and lath attachments shall be of corrosion -resistant materials. Attached per ASTM C 1063. R703.6.2 Plaster. Plastering w/ portland cement plaster shall be not less than three coats when applied over metal lath or wire lath and shall be not less than two coats when applied over masonry, concrete. R703.6.3 Water-Resisitive Barriers. Water-resisitive barriers shall be Installed where cement plaster (stucco) is to be applied over wood -based sheathing, shall include a water -resistive vapor -permeable barrier. The individual layers shall be installed independently such that each layer provides a separate continuous plane and any fleshing intended to drain to the water -resistive barrier is directed between the layers. The barriers shall consist of one of the following. 1. Two layers of an approved water resistant barrier material in accordance with R703.2. 2. One layer of an approved water -resistive barrier (paperbacked stucco lath) over an approved synthetic house wrap. R703.8 Flashing. Approved corrosion -resistant flashing shall be applied shingle -fashion in a manner to prevent entry of water into the wall cavity or penetration of water to the building structural framing components. Flashing shall be installed at the following locations. • Exterior window/door openings. • Intersection of chimneys or other masonry contructions with frame walls. • Under and at the ends of masonry, wood or metal copings and sills. • Continuously above all projecting wood trim. • Where exterior porches, decks or stairs attach to a wall or floor assembly of wood -frame construction. • At wall and roof intersections • At Built-in gutters. Attic Ventilation Attic Ventilation to be in compliance with the Florida Building Code 5th Edition (2014) Residential R806. The Minimum net free ventilating area shall be 1/150 of the area of the vented space. The ventilating area may be reduced to 1/300 provided that at least 40% but no more than 50% of the required ventilation is provided in the upper portion of the space to be ventilated. Upper ventilators shall be located no more than 3 feet (measured vertically) below the ridge or highest point of the space, with the balance of the required ventilation provided by eave or cornice vents. -CALCULATIONS 13ASED ON THE FOLLOWING VALUES, SEE ROOF PLAN - (Values to be verified with Manufacturer Specifications) • RIDGE VENTS 15 SQ. IN. OF NET FREE AREA / LINEAR FT. • OFF -RIDGE VENTS 138 SO. IN. OF NET FREE AREA / UNIT • SOFFIT VENTS 7 SQ. IN. OF NET FREE AREA / SO. FT. • O'HAGIN WEATHERMASTER (Shingle Roof) - 72 SQ. IN. OF NET FREE AREA/ FT. (Sq. Ft. Soffit Needed) x 7 = (Sq. In. Needed) 172 - Amount of O'Hagin Vents Needed • LOMANCO DECK -AIR (Shingle Roofi - 9 SQ. IN. OF NET FREE AREA / FT. **Formula: (Sq. Ft. Soffit Needed) x 7 - (Sq. In. Needed) / 9 = (Linear Ft. of Deck -Air Needed) e O'HAGIN (Tile Roof) - 86.25 SQ. IN. OF NET FREE AREA / VENT "Formula: (Sq. Ft. Soffit Needed) x 7 - (Sq. In. Needed) 186.25 a Amount of allagin Vents Needed 0 0 z z z LU Cz (D z (1) (DV) C—f) 4--d LLJ (10 C) U — LU 0 CLI F_ E 0 V) 0 U) Cl) 00 ED r, b LU E 8 cce) M C CUP 3 !! "S c.4 0 - 0 U) = 1U) o C, :l; U. W 0 .2 0. < 0 Im 0 CL 0 -�c 6 Al N-C-11 D C If e�,_o W '0 R D I z UP.A 0� W cv, C uJ ;a 2-, e cl; z- LL 0,iffl­ 6FO To the best of the Engineer's knowledge, information, and belief, the structural plan s and specifications contained within these drawings comply with the Florida Building Code Sth Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. CD Z r-4 0 (1) r-, 11-� 4.J C:) U0 15 tD U.) (') c) C:, 4.J M Ln rL z 7 ON a) U11 L_ LL F- c>L z CIL 00 Z E%­ M z LU C:� _J C:) W to Z,< 00 �Wzl L1210 uci(o 861 Z5 Ln z Lr) 0 r.4 Z 0 U LU k ILL 0 0 Ng� Rij glo ui z z 2 LU Lr) 00 M kD X < Z < z 0 Ln z t_U z ui rn 1E SCALE AS NOTED DATE 2/24/2014 TECH: MJAMES VERSION No' 10 SHEET NO. 5.0 9 9 TYP @ 2 STORY H.B. F- - - - - - - Lo 2 STORY cc (2) #5 REBAR VERTICALS w/ in \ �3 FILLED CELL rr- -0 as i L Jo 4 �11 z - - - - - - - - - - - 11 co F o? I 10'-6- 4'-1111 F Ci I oil Ci 9 IT C? 4'-0" STEPS AS -3 1/2" SLOPE KITCHE SLAND &D CHASE REQUIRED PER LOW WALLS TO FIELD CONDITIONS ISLAND F 3-1/2" MIN 3000 PSI CONC. PROVIDE 1 Y2" SLAB FOR HERNANDO RECESS FOR COUNTY ONLY b SGD. REFER TO 3-1/2" MIN 2500 PSI CONC &D LO MASON'S SLOPE SLAB OVER 6 MIL 2STORY 31/2'. FOR WIDTH ViSQUEEN VAPOR BUILDER TO PROVIDE 'CC"\ (2) #5 REBAR L BARRIER APPLIANCE PROTECTION V WHEN REQUIRED PER FBC ERTICALS w/ in FILLED CELL 04 TYP @ 2 STORY L Y2" 2'-6" 2'-6" 1'-0" PROVIDE x 9" -31/2"S x x RECESS FOR FRT. DOORT— A OPE W/ (3) #5'S E.W. TOP OF CONCJ PAVER TO BE 4" k? F- BELOW FIN. FLR. STUB U P-1�O� 113--7j" 11-9 -0— ...... 2ND Fl- 0 FOR A/C Z? C� rG ��S3� --CJ --CJ 21-6" x 2-4- x i .-O,,--� W/ (3) #5-S E.W. C14 b 04 U) 19. INDICATES FILLED CELL w/ 3000 -jI PSI CONC. GROUT FROM FT. TO TYP @ 2 STORY BEAM W/ (1) #5 REBAR VERT ABOVE SLAB TYP @ ALL PLACES C� SHOWN HOOKED FTG. DOWELS 5" ro 00 T EMBED W/ 25" EXT. ABOVE SLAB "GRADE 40 STEEL" C14 HVAC CHASE BASED ON I I -J 0 0 LOCATION L 5-4- 16'-3" �6 J i ........ ............ ............... ...... ........ ............ ......... I ... 1i . . . iiiiiii ..... i. IN - ... i - - .. L�J-n I H.B.4- TYP @ 2 J STORY S6 4'4 5-4- 7-11 FOUNDATION PLAN SCALE: Y4"=V-0" NOTE: • WHERE PROJECT IS TO BE LOCATED IN KNOWN RADON GAS PREVALENT AREAS, APPENDIX "E" OF THE FBC 5th EDITION (2014) BUILDING IS TO BE IMPLEMENTED. CONCRETE STRENGTH IN THESE AREAS TO BE A MINIMUM OF 3000 P.S.I. THEREFORE, ANY AND ALL NOTES ON THESE PLANS THAT INDICATED 2500 P.S.I. SHALL BE REPLACED WITH 3000 P.S.I. FOR THE CONCRETE STRENGTH • SEE SHEET SN FOR SOIL & TERMITE NOTES. BORATE / BORACARE TREATED LUMBER IS AN ALTERNATE TERMITE PROTECTION TO SOIL POISONING W.W.M. PLACED IN SAWCUT x 1/4 SLAB UPPER 1/3 OF SLAB THICKNESS WHERE OR FIBERMESH r1/8" SHOWN ON REINF. SEE PLAN. FOUNDATION PLAN Uj LU CONTROL JOINT DETAIL, SCALE: 1 117=11'4' #5 CONT REINF. SEE FIND. FOR QUANTITY #5 X 25" X 25" CORNER BAR ONE FOR EA. HORIZ. REBAR, TYP. U.N.O. *Alternate: Fhe reinf. bars shall be *nt. around comer by cold *nding the bar w/ min. bar lap of 25". TYP. CORNER BAR DTL. SCALE: 1 1/2"=V-0" ce) 0 C� 0 z I Z LU U 0 LU Lh = E flu C) Uj E 8 0 o C) �s U. co 0 (1) CL < 0 A 8 I Do -C 0 e� well va: Ax �A -'a FLO Z UMW 4t, E S To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code 5th Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. C) z r14 0 (U N P-4 :h! C) Ln = O'D > U.) ro a CD ro z4-J M Ln U- F— C>L � C( U M 0. 00 z < E -j C:) W LU C:) F- 10 U 0. 4 00 05 zo- 0 > Lr) z z r*-4., Lr) M 0 0 r4,j LL 0 0 0 9 21 )d H < Z 2 z Ln 4 1 Lij X: < di z LU 0 $i ff z 00 M Z z z 0 1`71 v--q 0- Ln uj SCALE AS NOTED DATE 2/24/2014 TECH: MJAMES VERSION NO' 10 SHEET NO. 6.0 an61-01 N M UPLIFT CONNECTION CROSS-REFERENCE MARK SIMPSON STRONG TIE LISP MANUFACTURING, INC. 0 CONNECTOR CAPACITY FASTENERS CONNECTOR CAPACITY FASTENERS SYP SPF SYP SPF A HETA20 1810 9 - 10d x 1 1/2" HTA20 1615 1585 10 - 10d x 1 1/2" B HETA16 1810 9 - 10d x 1 1/2" HTA16 1615 1585 10 - 10d x 1 1/2" C— H2.5A 600 535 10 - 8d RT7A 670 565 10 - 8d X 1 1/2" D H3 1 455 320 18 - 8d RT3 610 525 18 - 8d X 1 1/2" E META20 1450 7 - 10d x 1 1/2" HTA20-18 1400 1400 10 - 10d X 1 1/2" F HHETA20 2235 10 - 10d x 1 1/2" G H10A 1340 1015 18 - 1 Od x 1 1/2" RT16A 1380 1160 9-1 Od X 1 1/2% 8-1 Od H HTT4 3610 3105 518"ANCH. 08) 10dxl-112 HTT4 2715 5/8' ANCH. /(20) 10dxl-1/2 i HTT5 4350 3740 5/8' ANCH. / (26) 10dxl-1/2' HTT5 3225 5/8- ANCH. /( 8) 10dxl-112 K HD3B * 3130 3050 15/8" DIA. BOLTS TDX2-TZ 2345 — 2 - 5/8" DIA. BOLTS L HD5B * 4505 3785 15/8- ANCH. 314- STUD BOLTS TDX6 5320 — 2 - 7/8" DIA. BOLTS M HQ7B * 6645 5650 17/8"ANCH. 3/4"STUD BOLTS TDX1 0 7845 — 4 - 7/8" DIA. BOLTS N_ LUS26 1165/1070 1()05/915 8 - 10d x 3" JUS26 1115/1060** — 8 - 10d P HUS26 1550/3335 1335/2820 20 - 16d x 3 1/2" HUS26 1925/3295 — (20)16d x 3-1/2" Q HUS28 2000/4220 1720/3125 30 - 16d x 3 1/2" HUS28 2570/4345 — 30d -1 6d x 3-1/2" R MTS12 1000 860 14 - 1 Od x 1 1/2" MTW12 1195 1005 14-10d x 1-1/2" S; MTS16 1000 860 14 - 1 Od x 1 1/2" MTW16 1195 1005 14-1 Od x 1-1 /2" T MTS20 1000 860 1 14 - 1 Od x 1 1/2" MTW20 1195 1005 14-1 Od x 1-1 /2" U MGT/MUGT 3140 3140 22-10dX(1)518"ATR 5" EMBED W/ SIMPSON "SET" EPDXY V LGT2 2150 1850 (16)16d SINKERS & (7) 1/4" x 2-1/4" TITIENS LUGT2 1850 1810 (16)10d NAILS AND (5) 1/4'. x 3"WEDGE BOLTS 1 IWI HTS 20 1450 1245 24-1 Od X 1 1/2" HTW20 1530 1285 24-1 Od X 1 1/2" Spi 585 535 10 - 10d SPT22 685 8 - 10d SP2 1065 12 - 10d SPT24t::t 1030 1 12 - 10d HCP2 645 555 1 12-1 Od X 1 1/2- L MINIMUM 3"MEMBER REACTIONS ARE FOR ROOF LOADS ONLY DO NOT DRIVE NAILS THROUGH THE TRUSS PLATE ON THE OPPOSITE SIDE OF THE TRUSS, WHICH COULD FORCE THE PLATE OFF OF THE TRUSS. ALL EPDXY ANCHORS USP CIA-7000C NOTE: DOUBLE FELT REQ'D ON ROOF PITCHES 3/12 & LOWER. LOADS -- ROOF = L / 360 FLOOR = L / 480 W/ 3/8" MAX DEFLECTION. FLOOR JOIST SPACING SHALL BE MAX OF 19.2" OC FOR HARDWOOD & TILE AREA'S & 24" OC FOR CARPET AREA'S DROP HIP DETAIL 2-0-0 MAXIUM SPACING ON VERTICALS OF (B) TRUSS (+ +) A 11 A I I I I\N A (A) (+ "\—1 OR 2 PLY CARRIER -rl—T-T- 1-8-8 CLEAR GAP BETWEEN (B) TRUSSES 61 'FASTEN EACH (B) TRUSS WEB TO EACH (A) TRUSS TOP CHORD @ EVERY INTERSECTING POINT SHOWN ON THE HIP TRUSS SYSTEM BELOW. FASTEN TOP CHORDS OF EACH (B) TRUSS TO THE TOP CHORDS OF (A) TRUSSES AT EVERY OTHER INTERSECTING POINT (--). INTERSECTING POINT TO BE FASTENED WITH 2 - 16d COMMON NAILS OR 0. 1 28"x 3"GUN NAILS. FASTEN BOTTOM CHORD OF (B) TRUSS TO TOP CHORD OF CARRIER TRUSS WITH THE SAME SPECIFIED COMMON NAILS OR GUN NAILS AT 49'OC. (+) <iv IN LIEU OF PREFABRICATED HIP PLANING TRUSSES, (B) 20 SO. PINE #2 OR #2 PT. STICK LUMBER (LAID FLAT WISE) MAY BE USED. FOLLOW FASTENING SCHEDULE AS DEFINED FOR HIP PLANING TRUSSES. R1 L STICK FRAMING SPLICING IS ALLOWED BETWEEN TRUSSES OR AT TRUSS 1OR F R INTERSECTIONS. SPLICING 2 xj!V 0 T�Ig�l TO BE STAGGERED BETWEEN COMMON TRUSSES, NO CATS REQUIRED UNDER STICK FRAMING SPLICING. MINIMUM LENGTH OF STICK FRAMING TO BE 5'-O"ON A HORIZONTAL PROJECTION. NOTE: SEE SHEET D-1 FOR ROOF FRAMING DETAILS 1. (2) 12d TOENAILS EACH SIDE OF FLOOR TRUSS TO WALL OR BEAM BELOW TYP @ INT. BEARING U.N.O. STRUCTURAL SHEATHING (SEE TB1 3 FOR NAILING INFO.)- 2x CONT. W/ (2)-12d NAILS @ EA. TRUSS 2X4 CONT. RIBBON W/ (4) 16d NAILS @ EA. TRUSS 2x BLOCKING W/(2) -12d NAILS @ EA. END 8d NAILS @ 24" O.C. TO BLOCKING — STRUCTURAL SHEATHING 2x STUDS SEE PLAN FOR INFO PLYWOOD 2x6 CONT. W/ (2)-12d NAILS @ EA. TRUSS CANTILEVER FLOOR TRUSS I ik SEE PLAN . '-f TRUSS BRG. CONNECTOR AT EACH TRUSS, SEE PLAN LINTEL SEE PLAN CO3� CANT. FLOOR TRUSS CONN. SCALE: 314" = V-0" MAIN FRAMING PLAN SCALE: Y4"=V-0" (D z z z CL (nv) Z Cz (3) C-1) 4--J LU 0 LU E 0 2 C, 0 CD rn I- c) . -M 'M - E 0' � 'r- C14 0 O� C- LL 0 < 6 A RD. I WS z vis E z co.cq Ja- L" aj W Z 0 I It Z W To the best of the Engineer's knowledge, Information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code Sth Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. CD z r-4 0 v N 1-01 4-1 C) U0 — =) tD > C) M Ln z 0 d) — Ln LL e--% zL- F- a> � fy) M T-q cl� U a OC) z E z WLLI C:I, -i C:) z g 0, Lzu Izi E16 8 L, I F- 0 > Ln ;r z Ln LL cr 41 0 0 0 U —j LL- U- 0 r-4 0 cr 6OA80 :W < Z z CY In V-4 1 < Lij 2: < z 8-1 log 00 M Z z '5 t-u Uj 0 rn V-4 0- IV,) SCALE AS NOTED DATE 2/24/2014 TECH: MIAMES VERSION NO - 10 SHEET NO. 7.0 TY Ulm CKING UPLIFT CONNECTION CROSS-REFERENCE MARK SIMPSON STRONG TIE USP MANUFACTURING, INC. 0 CONNECTOR CAPACITY FASTENERS CONNECTOR CAPACITY FASTENERS SYP SPF SYP SPF A HETA20 1810 9 - 10d x 1 1/2" HTA20 1615 1585 10 - 10d x 1 1/2" B HETA16 1810 9 - 10d x 1 1/2" HTA1 6 1615 1585 10 - 10d x 1 1/2" C H2.5A 600 535 10 - 8d RT7A 670 565 10 - 8d X 1 1/2" D H3 1 455 320 8 - 8d RT3 610 525 18 - 8d X 1 1/2" E META20 1450 7 - 10d x 1 1/2" HTA20-18 1400 1400 10 - 1 d X 1 1/2" F HHETA20 2235 10 - 10d x 1 1/2" G H10A 1340 1015 18 - 10d x 1 1/2" RT16A 1380 liAn cl-lArl x 1 119-8 8-10d H HTT4 3610 3105 518"ANCH. /08) 10dxl-112 HTT4 2715 5/8"ANCH. /(20) 10dxl-112 i HTT5 4350 3740 1518- ANCH. / (26) 10dx1-1/T HTT5 3225 518"ANCH. 1 8) 10dxl-112 K HD3B * 3130 3050 5/8"DIA. BOLTS TDX2-TZ 2345 — 2 - 5/8" DIA. BOLTS L HD5B * 4505 3785 5/8"ANCH, 3/4* STUD BOLTS TDX6 5320 — 2 - 7/8"DIA. BOLTS M HD7B * 6645 5650 7/8"ANCH. 3/4" STUD BOLTS TDX10 7845 — 4 - 7/8"DIA. BOLTS N I t IS96 1165/1070 10051915 8 - 10d x 3" JUS26 1115/1060** — 8 - 10d P, HUS26 1550/3335 1335/2820 20 - 16d x 3 1/2" HUS26 1925/3295 — (20)16d x 3-1/2" Q HUS28 2000/4220 1720/3125 30 - 16d x 3 1/2" HUS28 2570/4345 — 30d -1 6d x 3-1/2" R MTS12 1000 860 14 - 10d x 1 1/2" MTW12 1195 1005 14-10d x 1-1/21, S MTS16 1000 860 14 - 10d x 1 1/2" MTW16 1195 1005 14-10d x 1-1/2" T MTS20 1000 860 14 - 1 Od x 1 1/2" MTW20 1195 1005 14-10d x 1-1/2" U MGT/MUGT 3140 3140 22 - 10d X (1) 5/8- ATIR W/ 5- EMBED W/ SIMPSON 'SET- EPDXY V LGT2 2150 1850 (16)16d SINKERS & (7) 1/4" x 2-1/4" TITENS LUGT2 1850 1810 _ (16)10d NAILS AND (5) 1/4"x 3" WEDGE BOLTS "X" HTS 20 1450 1245 24-1 Od X 1 1/2" HTW20 1530 1285 24-1 Od X 1 1/2' spi 585 535 10 - 10d SPT22 685 8 - 10d SP2 1065 605 12 - 10d SPT24 1030 12 - 10d I HCP2 645 555 12-1 Od X 1 1/2" MINIMUM 3"MEMBER REACTIONS ARE FOR ROOF LOADS ONLY DO NOT DRIVE NAILS THROUGH THE TRUSS PLATE ON THE OPPOSITE SIDE OF THE TRUSS, WHICH COULD FORCE THE PLATE OFF OF THE TRUSS. ALL EPDXY ANCHORS USP CIA-7000C NOTE: DOUBLE FELT REQ'D ON ROOF PITCHES 3/12 & LOWER. LOADS — ROOF = L / 360 FLOOR = L / 480 W/ 3/8" MAX DEFLECTION. FLOOR JOIST SPACING SHALL BE MAX OF 19.2"OC FOR HARDWOOD & TILE AREA'S & 24" OC FOR CARPET AREA!S DROP HIP DETAIL. 2-0-0 MAXIUM SPACING ON VERTICALS OF (B) TRUSS A I I I I X\ (6) \—(B) A (A) I+ OR 2 PLY CARRIER 1-8-8 CLEAR GAP BETWEEN (B) TRUSSES 6") 'FASTEN EACH (B) TRUSS WEB TO EACH (A) TRUSS TOP CHORD @ EVERY INTERSECTING POINT SHOWN ON THE HIP TRUSS SYSTEM BELOW. FASTEN TOP CHORDS OF EACH (B) TRUSS TO THE TOP CHORDS OF (A) TRUSSES AT EVERY OTHER INTERSECTING POINT (--). INTERSECTING POINT TO BE FASTENED WITH 2 - 16d COMMON NAILS OR 0. 128"x 3"GUN NAILS. FASTEN BOTTOM CHORD OF (B) TRUSS TO TOP CHORD OF CARRIER TRUSS WITH THE SAME SPECIFIED COMMON NAILS OR GUN NAILS AT 48"OC. (+) IN LIEU OF PREFABRICATED HIP PLANING TRUSSES, (B) 20 SO. PINE #2 OR #2 PT. STICK LUMBER (LAID FLAT WISE) MAY BE USED. FOLLOW FASTENING SCHEDULE AS DEFINED FOR HIP PLANING TRUSSES. R1 STICK FRAMING SPLICING IS ALLOWED BETWEEN TRUSSES OR AT TRUSS 1 R2PLY AA� —J —(A) INTERSECTIONS. SPLICING 2x CCINT� TO BE STAGGERED BETWEEN COMMON TRUSSES, NO CATS REQUIRED UNDER STICK FRAMING SPLICING. MINIMUM LENGTH OF STICK FRAMING TO BE 5'-O"ON A HORIZONTAL PROJECTION. NOTE: SEE SHEET D-1 FOR ROOF FRAMING DETAILS 1. (2) 12d TOENAILS EACH SIDE OF FLOOR TRUSS TO WALL OR BEAM BELOW TYP @ INT. BEARING U.N.O. ROOF FRAMING PLAN SCALE: Y4"=1'-0" D L -` z c?) CD 0 Z(09 zQ- 13 z U -0 Ln (D Q) C-/) 4--J Lu U 0 LU E M IxI C14 a) Cn UJI 8 RON 0) co 0 - 04 00 = . C) S = IL 00 0 0 CL CLI Ng < 0 1 0) 0 'W 0) 0 _a D. N C 11 D 17 W__0 CD C"! %— C!:b n04 z RA 1� 0 U& U3 z < L 0 LL -M SJO, To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code Sth Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. z 0 cu 1-4 :Lj . C:) V) :3 to > U-) C) C) 4-J V) M Ln in V) 0 IN — LL CL 00 z < E z 3i z M LU C:) F- -j (D W to z g 0 1N CU > -CR Ln z D CU Lr) LL CC 0 0 0 U LL. 0 LL 0 0 r4 Z Uj Ln 4 Lli E < Z x < z c3 00 M kD co 0 Ln r�l z 5 UJI 9 0. V) Fa SCALE AS NOTED DATE 2/24/2014 TECH: MIAMES VERSION No' 10 SHEETNO. 7.1 GENERAL INSTALLATION N TES 1 . Provide full mortar head and bed joints. 2, Shore filled lintels as required. 3, Installation of lintel must comply with the architectural and/or structural drawings. 4. U-Llntels are manufactured with 5-1/2" long notches at the ends to accommodate vertical call reinforcing and groutIng. 5. All lintels meet or exceed U360 vertical deflection, except lintels 17'-4" and longer with a nominal height of 8" meet or exceed L11 80. 6. Bottom field added rebar to be located at the bottom of the lintel cavity, 7. 7/32" diameter wire stirrups are welded to the bottom steel for mechanical anchorage. 8. Cast -In -place concrete may be provided in composite lintel In lieu of concrete masonry units. 9. Safe load ratings based on rational design analysis per ACI 318 and ACI 530 10, Product Approvals: Miami Dade County, Florida Nos.03-0605.05 and 03-0605.04. 11. The exterior surface of lintels installed in exterior concrete masonry walls shall have a coating of stucco applied in accordance with ASTM C-926 or other approved coating. 12. Lintels loaded simultaneously with veritcal (gravity and uplift) and horizontal (lateral) loads shoud be checked for combine loading with the following equation: Applied vertical load + Applied horizontal load Safe vertical load Safe horizontal load <1 .0 GENERAL CONCRETE LINTEL SCHEDULE APPROVED LINTEL MANUFACTURERS: CASTE-CRETE, QUALITY 8F8-1B/1T 8F8-0B/1T 8RF6-0B/1T rEIN (A (P 0 0 0 (0 .0 0 0 0 8 81TF__14-0B/1T 8F16-0B/1T 8F16-1B/1T '1� LJ 0 8F20-0B/1T 8F44 1B/1T8F40 1B/1T BRF40 0B/1T 8F32 1B11T J FORM & GROUT SOLID 0 ) �� #5 BAR CONT. 8F12-1B/1T (0 'V'LINTEL DETAIL SCALE - N.T.S. P N Me - me 02 00 so E. no so go 'm TYPE DESIGNATION 5 REBAR MIN. AT TOP (1) RECI'D ALTERNATE POWERS F = FILLED WITH GROUT / U = UNFILLED R = RECESSED -1r2" CLEAR STEEL LINTEL 4 A QTY. OF #5 A REBA @ BOTTOM OF LINML CAVITY 4 —..*-C.M.U. #5 REBAR AT TOP D_- MIN. (1) REa 1-1/2" CLEAR 8F16- B/1T 4 0 > 6 - Z ED -0 —GROUT J tNOMINAL, E QUANTITY OF A -#5 REBAR AT 0) 1— #5 REBAR AT WIDTH 0 0 BOTTOM OF TOP 0 `1W LINTEL CAVITY Lu Lu 0 U) C, 8 1- X Lu Z_� NOMINAL- _ZOTTOM 0 cr d 2 � HEIGHT REINFORCING , PROVIDED IN cr ui > 3: #5 REBAR AT BOTTC 7-5/8"ACTUAL 8- NOMINAL WIDTR" LINTEL <1 AS INDICATED E (VARIES) L-6 MATERIALS 1. re precast lintals = 3500 psi. 2. fc prestressed lintels = 6000 psi. 3. grouted per ASTM C476 fg = 3000 psi w/ 4. maximum 361 aggregate and T'to 11 " slump. 5. Concrete masonry units (CMU) per ASTM C90 w/ minimum net area compressive strength = 1900 psi. 6. Reber per ASTM A615 Grade 60. Prestressing strand per ASTM A416 grade 7. 270 low relaxation. 7/32 wire per ASTM A510. 8. Mortar per ASTM C270 type M or S. L:NTEL MINIMUM DEPTHS ARE CALLED OUT ON LINTEL PLAN, IF CONTRACTOR INSTALLS A DEEPER L NTEL THAN INDICATED ON THE PLAN, DOING THIS INCREASES THE STRENGTH OF THE LINTEL AND IS APPROVED WITHOUT ENGINEERING LETTER, IF A SMALLER LINTEL IS INSTALLED CONTACT E.O.R. FOR APPROVAL. (SEE LINTEL PLAN FOR SCHEDULE) 2x8 #2 SYP STUDS @ 8" O.C. W/ (2) USP MSTAM36 STRAPS EACH STUD ((1) STRAPS EACH SIDE) CENTERED W/ (13) 10d NAILS & (8) Y4" TITENS OR (2) 2x8 #2 SYP STUDS @ 16" O.C. W/ (4) USP MSTAM36 STRAPS ((2) STRAPS EACH SIDE) 2x8 #2 SYP P.T. BASE PLATE W/ Y2" EPDXY ANCHOR OR Y2" J BOLT W/ MIN. 7" EMBEDMENT @ 32" O.C. & 6" FROM EACH END 16 GAUGE POWERS STEEL BOXED LINTEL POWERS STEEL BOXED LINTEL NOTES (ALT.) ONLY IF NOTED ON LINTEL PLAN 1. Refer to manufacturees specifications for Installation. 2. Contractor to provide proper protection of lintel to prevent rusting Refer to manufacturees specifications. 3. If lintel Is scratched or damaged refer to Powers Steel for repair. 4. Lintel depth to match precast depth. One #5 Bar required at top see lintel plentcletails for bottom steel required. 5. A bonding agent must be applied to the Steel Box Ilmels prior to applying the cementItiuos coating. See contractor specifications STRUCTURAL SHEATHING ATTACHED PER NAILING SCHEDULE OL SEE PLAN `F TMALL T�1-8- KNOCKOUT COURSE -f-A W/ (1) #5 CONT. SEE PLAN FOR FILLED CELL SPACING WALL SPLICE DETAIL SCALE: 1" = 1'-0" 5'-8" LL LINTEL PLAN SCALE: Y4"=1'-0" 0 U) Z Z W Z0- Z Ul) 0 Q) C-41 4-J LU U 0 LU V) E C) p CN 4) M LU 8 ONOE M 00 -8 M, 09,0 -r 6 LL CO co < 0 _2L_\_ C-1 Z �,o r OR L-L . 'A' U U FLd te To the best of the Engineer's knowledge, Information, and belief, the structural plans and specifications contained n t ese raw ngs comp V w t t a F or a u ng Code 5th Edition (2014) Residential. Engineer's signature and seal Is only or the structural engineering portions o the drawing pages bearing Engineer's signature and seal. Z 0 0-4 4-J C:) V) — =3 C:) U-) 4-0 Ln d. V) Z 0 — Ln Z U_ Ce '00 Z E Z UJ F- W %D �5 Z.< UA.. 4�� 85 0 Z Ln Z Ln 0 r.4 U LU F _ - 19 ;Z 0 id _J < Z Z A Lu LU Ln 00 cri %D Z < Z < Z tu- 0 LrJ I N Z rn. T-4 . 0. 1 (A I SCALE AS NOTED DATE 2/24/2014 TECH: MJAMES VERSION NO' 10 SHEET NO. 8.0 - - I NOTE: BORATE/ SENTRA CON SYSTEM APPLIED TO ALL FRAME MEMBERS WITHIN 24" A.F.F. 1) METHOD OF TREATMENT SHALL BE APPROVED BY THE GOVERNING JURISDICTION "LIQUID BORATE OR BOR-A-COR" PRODUCT METHODS MUST BE DETERMINED AT PERMIT STAGE. 2) PRESSURE TREATED LUMBER THAT HAS BEEN CUT OR DRILLED THAT EXPOSES UNTREATED PORTIONS OF WOOD ARE REQUIRED TO BE FIELD TREATED TO PREVENT INSECT INFESTATION. ATTENTION: CHEMICAL CHANGES IN PRESSURE TREATED WOODS AS OF DECEMBER 31ST, 2003, CHROMATED COPPER ARSENATE (CCA-C) WILL NO LONGER BE PRODUCED FOR RESIDENTIAL OR GENERAL CONSUMER USE. SEVERAL NEW PRESSURE TREATED WOOD ALTERNATIVES HAVE BEEN CREATED TO REPLACE CCA-C. MANY OF THE NEW PRESSURE TREATED WOODS USE CHEMICALS THAT ARE CORROSIVE TO STEEL. IT IS THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THE TYPE OF WOOD TREATMENT AND TO SELECT APPROPRIATE CONNECTORS THAT RESIST CORROSION. FOR EXAMPLE, ACQ-C. ACQ-D, CBA-A, ORCA-B REQUIRE HOT -DIPPED GALVANIZED OR STAINLESS STEEL FASTENERS. DOT SODIUM BORATE (SBX) DOES NOT. REQUIRED SAFETY GLAZING IN HAZARDOUS LOCATIONS (RE: FRC R308.4) R308.3 HUMAN IMPACT LOADS. INDIVIDUAL GLAZED AREAS INCLUDING GLASS MIRRORS IN HAZARDOUS LOCATIONS SUCH AS THOSE INDICATED AS DEFINED IN SECTION R308.4 SHALL PASS THE TEST REQUIREMENTS OF CPSC 16 CFR, PART 1201 CRITERIA FOR CATEGORY I OR CATEGORY 11 AS INDICATED IN TABLE R308.3 EXCEPTIONS: 1. POLISHED WIRED GLASS FOR USE IN FIRE DOORS AND OTHER FIRE RESISTANT LOCATIONS SHALL COMPANY WITH ANSI Z97.1 2. LOUVERED WINDOWS AND JALOUSIES SHALL COMPANY WITH SECTION R308.2 R308.4 HAZARDOUS LOCATIONS. THE FOLLOWING SHALL BE CONSIDERED SPECIFIC HAZARDOUS LOCATIONS FOR THE PURPOSE OF GLAZING: 1. GLAZING IN SWINGING DOORS EXCEPT JALOUSIES. 2. GLAZING IN FIXED AND SLIDING PANELS OF SLIDING DOOR ASSEMBLIES AND PANELS IN SLIDING AND BIFOLD CLOSET DOOR ASSEMBLIES. 3. GLAZING IN STORM DOORS. 4. GLAZING IN ALL UNFRAMED SWINGING DOORS. 5. GLAZING IN DOORS AND ENCLOSURES FOR HOT TUBS, WHIRLPOOLS, SAUNAS, STEAM ROOMS, BATHTUBS, AND SHOWERS. GLAZING IN ANY PART OF A BUILDING WALL ENCLOSING THESE COMPARTMENTS WHERE THE BOTTOM EXPOSED EDGE OF THE GLAZING IS LESS THAN 60 INCHES (1524MM) MEASURED VERTICALLY ABOVE ANY STANDING OR WALKING SURFACE. 6. GLAZING, IN AN INDIVIDUAL FIXED OR OPERABLE PANEL ADJACENT TO A DOOR WHERE THE NEAREST VERTICAL EDGE IS WITHIN A 24-INCH(610MM) ARC OF THE DOOR IN A CLOSED POSITION AND WHOSE BOTTOM EDGE IS LESS THAN 60 INCHES (1524MM) ABOVE THE FLOOR OR WALKING SURFACE. 7. GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL, OTHER THAN THOSE LOCATIONS DESCRIBED IN ITEMS 5 AND 6 ABOVE, THAT MEETS ALL OF THE FOLLOWING CONDITIONS: 7.1 EXPOSED AREA OF AN INDIVIDUAL PANE GREATER THAN 9 SQUARE FEET (0.836 M2). 7.2 BOTTOM EDGE LESS THAN 18 INCHES (457 MM) ABOVE THE FLOOR. 7.3 TOP EDGE GREATER THAN 36 INCHES (914 MM) ABOVE THE FLOOR. 7.4 ONE OR MORE WALKING SURFACES WITHIN 36 INCHES (914 MM) HORIZONTALLY OF THE GLAZING. 8. ALL GLAZING IN RAILINGS REGARDLESS OF AN AREA OR HEIGHT ABOVE WALKING SURFACE. INCLUDED ARE STRUCTURAL BALUSTER PANELS AND NONSTRUCTURAL IN FILL -PANELS. 9. GLAZING IN WALLS AND FENCES ENCLOSING INDOOR AND OUTDOOR SWIMMING POOLS, HOT TUBS AND SPAS WHERE THE BOTTOM EDGE OF THE GLAZING IS LESS THAN 60 INCHES (1524 MM) ABOVE A WALKING SURFACE AND WITHIN 60 INCHES (1524 MM) HORIZONTALLY OF THE WATER'S EDGE. THIS SHALL APPLY TO SINGLE GLAZING AND ALL PANES IN MULTIPLE GLAZING. 10. GLAZING ADJACENT TO STAIRWAYS, LANDINGS, AND RAMPS WITHIN 36 INCHES (914 MM) HORIZONTALLY OF A WALKING SURFACE WHEN THE EXPOSED SURFACE OF THE GLASS IS LESS THAN 60 INCHES (1524 MM) ABOVE THE PLANE OF THE ADJACENT WALKING SURFACE. 11. GLAZING ADJACENT TO STAIRWAYS WITHIN 60 INCHES (1524 MM) HORIZONTALLY OF THE BOTTOM TREAD OF A STAIRWAY IN ANY DIRECTION WHEN THE EXPOSED SURFACE OF THE GLASS IS LESS THAN 60 INCHES (1524 MM) ABOVE THE NOSE OF THE TREAD. EXCEPTION: THE FOLLOWING PRODUCTS, MATERIALS AND USES ARE EXEMPT FROM THE ABOVE HAZARDOUS LOCATIONS: 1. OPENINGS IN DOORS THROUGH WHICH A 3-INCH(76 MM) SPHERE IS UNABLE TO PASS. 2. DECORATIVE GLASS IN ITEMS 1, 6 OR 7. 3. GLAZING IN SECTION R308.4, ITEM 6, WHEN THERE IS AN INTERVENING WALL OR OTHER PERMANENT BARRIER BETWEEN THE DOOR AND THE GLAZING. 4. GLAZING IN SECTION R 308.4, ITEM 6, IN WALLS PERPENDICULAR TO THE PLANE OF THE DOOR IN A CLOSED POSITION OR WHERE ACCESS THROUGH THE DOOR IS TO A CLOSET OR STORAGE AREA 3 FEET (914 MM) OR LESS IN DEPTH. GLAZING IN THESE APPLICATIONS SHALL COMPANY WITH SECTION R308.4, ITEM 7. 5. GLAZING IN SECTION R308.4, ITEMS 7 AND 10, WHEN A PROTECTIVE BAR IS INSTALLED ON THESE ACCESSIBLE SIDE(S) OF THE GLAZING 36 INCHES ± 2 INCHES (914 ± MM 51 MM) ABOVE THE FLOOR. THE BAR SHALL BE CAPABLE OF WITHSTANDING A HORIZONTAL LOAD OF 50 POUNDS PER LINEAR FOOT KG/M) WITHOUT CONTACTING THE GLASS AND BE A MINIMUM OF 1 X INCHES (38 MM) IN HEIGHT. 6. OUTBOARD PANES IN INSULATING GLASS UNITS AND OTHER MULTIPLE GLAZED PANELS IN SECTION R308.4, ITEM 7, WHEN THE BOTTOM EDGE OF THE GLASS IS 25 FEET (7620 MM) OR MORE ABOVE GRADE, A ROOF, WALKING SURFACES, OR OTHER HORIZONTAL [WITHIN 45 DEGREES (0.79 RAD) OF HORIZONTAL] SURFACE ADJACENT TO THE GLASS EXTERIOR. 7. LOUVERED WINDOWS AND JALOUSIES COMPLYING WITH THE REQUIREMENTS OF SECTION R308.2. 8. MIRRORS AND OTHER GLASS PANELS MOUNTED OR HUNG ON A SURFACE THAT PROVIDES A CONTINUOUS BACKING SUPPORT. 9. SAFETY GLAZING IN SECTION R308.4, ITEMS 10 AND 11 IS NOT REQUIRED WHERE: 9.1 THE SIDE OF STAIRWAY, LANDING OR RAMP HAS A GUARDRAIL OR HANDRAIL, INCLUDING BALUSTERS OR IN -FILL PANELS, COMPLYING WITH THE PREVISIONS OF SECTION 1012 AND 1607.7 OF THE FLORIDA BUILDING CODE, BUILDING; AND 9.2 THE PLANE OF THE GLASS IS GREATER THEN 18 INCHES (457 MM) FROM THE RAILING. SPECIFICATIONS 1. CONSTRUCTION: ACI 318-11 BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE ACI 530-11, ASCE 51TMS 402-11 & ACI 530.1-11, ASCE 6/TMS 602-11 SPECIFICATIONS FOR MASONRY STRUCTURES. 1.1.3. ASTM C270-07a, C90-06b & C91-05 SPECIFICATIONS FOR MASONRY STRUCTURES 1.1.4. NATIONAL DESIGN SPECIFICATIONS (NDS) FOR WOOD CONSTRUCTION, 2012 EDITION, AND ALL ACCOMPANYING SUPPLEMENTS. 1.1.5. FLORIDA RESIDENTIAL CODE (FRC), FLORIDA BUILDING CODE (FBC) 5th ad. (2014) 1.1.6. "MANUAL OF STEEL CONSTRUCTION, ALLOWABLE STRESS DESIGN-, BY THE AMERICAN INSTITUTE OF STEEL CONSTRUCTION, (AISC) 13TH EDITION. "DESIGN SPECIFICATION FOR LIGHT METAL PLATE CONNECTED WOOD TRUSSES" BY THE TRUSS PLATE INSTITUTE TR11-02. 1.2. DESIGN: 1.2.1. ACI 301-11 BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE 1.2.2. ACI 530-11, ASCE 5/TMS 402-11 & ACI 530.1-11, ASCE 6/TMS 602-11 SPECIFICATIONS FOR MASONRY STRUCTURES. 1.2.3. ASTM C270-07a, C90-06b & C91-05 SPECIFICATIONS FOR MASONRY STRUCTURES 1.2.4. NATIONAL DESIGN SPECIFICATIONS (NDS) FOR WOOD CONSTRUCTION, 2012 EDITION, AND ALL ACCOMPANYING SUPPLEMENTS. 1.2.5. PLYWOOD DESIGN SPECIFICATIONS (APA) 1.2.6. FLORIDA BUILDING CODE (FBC) 5th ad. (2014) AND FLORIDA BUILDING CODE 5th ad. RESIDENTIAL (FBCR) 1.3. SHOP DRAWINGS: 1.3.1. THERE SHALL NOT BE ANY DEVIATIONS FROM THESE DESIGN PLANS BY OTHERS DURING THE PREPARATION OF SHOP DRAWINGS WITHOUT WRITTEN APPROVAL FROM THE ENGINEER OF RECORD. 1.3.2. ALL SHOP DRAWINGS ARE TO BE SUBMITTED TO THE ENGINEER OF RECORD PRIOR TO THE COMMENCEMENT OF CONSTRUCTION. 1.3.3. ALL ROOF AND FLOOR TRUSS SHOP DRAWINGS ARE TO BE SIGNED AND SEALED BY A FLA, REG. PE. AND SHALL INCLUDE: DRAWINGS AND CALCULATIONS, REACTIONS AND BEARING POINTS, BRACING REQUIREMENTS, AND CONNECTIONS TO SUPPORTING TRUSS MEMBERS. 2. DESIGN LOADS 2.1. DEAD LOADS: 2.1.1. UNIT WEIGHT OF SOIL, COMPACTED: 120 PCF 2.1.2. UNIT WEIGHT OF REINFORCED CONCRETE: 150 PCF 2.1.3. UNIT WEIGHT OF 8"C.M.U. BLOCK: 55 PSF 2.1.4. 1ST FLOOR SUPERIMPOSED LOAD: 20 PSF 2.1.5. UNIT WEIGHT OF 2x4 PARTITION WALLS: 11 PSF 2.1.6. UNIT WEIGHT OF 2x6 BEARING WALLS: 12 PSF 2.1.7. BALCONIES & DECKS: 15 PSF 2.1.8. TILE ROOF TOPCHORD: 15 PSF BOTTOM CHORD: 10 PSF 2.1.9. SHINGLE ROOF TOPCHORD: 7PSF BOTTOM CHORD: 10 PSF 2.1-10. FLOOR TRUSSES 15 2.2. LIVE LOADS: 2.2.1. SIDEWALK AND DRIVEWAY LOAD: 250 PSF 2.2.2. GARAGELOADS: 40 PSF 2.2.3. PARTITIONED ROOMS: 40 PSF 2.2.4. BALCONY AND DECKS: 60 PSF-UNDER 100 sq. ft. 2.2.5. STAIRWAYS AND LANDINGS: 40 PSF 2.2.6. SLEEPING ROOMS: 30 PSF 2.2.7. FLOOR TRUSS TOP CHORD MINIMUM: 40 PSF 2.2.8. ROOFTRUSS TOP CHORD MINIMUM: 20 PSF BOTTOM CHORD (ATTIC W/O LIMITED STORAGE): 10 PSF (NON -CONCURRENT) BOTTOM CHORD (ATTIC W1 LIMITED STORAGE): 20 PSF 2.3. RAILING LOADS: 2.3.1. ALL RAILING AND GUARD RAIL SYSTEM'S ARE TO BE DESIGNED TO WITHSTAND A CONCENTRATED LOAD OF 200 POUNDS APPLIED AT ANY POINT AND IN ANY DIRECTION ON THE RAILING. 2.3.2. ALL RAILING AND GUARD RAIL SYSTEM'S ARE TO BE DESIGNED TO WITHSTAND A HORIZONTAL LOAD OF 50 PLIF ON THE GUARDRAIL AND A SIMULTANEOUS LOAD OF 100 PLIF APPLIED VERTICALLY DOWNWARD AT THE TOP OF THE GUARDRAIL 2.3.3. GUARDRAIL SYSTEM SHALL BE DESIGNED TO WITHSTAND 2001b CONCENTRATED HORIZONTAL LOAD APPLIED ON 1 SQ. FT. AT ANY POINT IN THE SYSTEM. 2.3.4. 2.3,1.,2.3.2 & 2.3.3. ARE NOT REQUIRED TO BE APPLIED SIMULTANEOUSLY, BUT EACH SHALL BE APPLIED TO PRODUCE THE MAXIMUM STRESSES IN THE MEMBER COMPONENTS. 2.4. WIND LOADS: 2.4.1. WIND DESIGN TO BE CONDUCTED IN ACCORDANCE WITH SECT. R301.2 OF THE FBC 5th ad. (2014), AND CONDUCTED BASED ON A140 MPH 3 SECOND GUST, EXPOSURE "C", IMPORTANCE FACTOR "I"= 1.0. ENCLOSED BUILDING 2.4.2. NET UPLIFT DEAD LOADS - 10 PSF SHINGLE, 15 PSF TILE 2.4.3. WIND LOAD DETERMINATION BASED ON ASCE 7-10 2.5. DEFLECTIONS: 2.6.1. FLOOR TRUSSES SHALL LIMIT DEFLECTION TO U480TIMES THE SPAN FOR LIVE LOADS AND U240TIMES THE SPAN FOR TOTAL LOAD. 3. DESIGN METHOD 3.1. LOAD FACTOR DESIGN: THE LOAD FACTOR DESIGN METHOD WAS USED TO DESIGN: CAST -IN -PLACE CONCRETE SLABS AND FOOTINGS 3.2. SERVICE LOAD DESIGN: 3.2.1. THE SERVICE LOAD DESIGN METHOD WAS USED TO DESIGN: MASONRY WALLS AND LINTELS INTERIOR AND EXTERIOR WOOD FRAMING AND SHEATHING STAIRS AND FLOOR FRAMING ROOF FRAMING, SHEATHING AND UPLIFT 3.3. LOAD COMBINATIONS FOR LRFD DESIGNS: 3.3.1. THE FOLLOWING LOAD COMBINATIONS WERE DESIGNED FOR: TOTAL DL + FLOOR LL + ROOF LL TOTAL DL + FLOOR LL + WL TOTAL DL + WL 3.3.2. ALL ROOF AND FLOOR TRUSSES SHALL BE DESIGNED TO RESIST THE WORST LOAD COMBINATION RESULTING IN THE MAXIMUM STRESSES PLACED ON THAT COMPONENT. BOTH PARTIAL, FULL, AND ALTERNATING SPAN LOADING ARE TO BE CONSIDERED. 3.4. DESIGN ASSUMPTIONS: 3.4.1. ALL FOUNDATIONS ARE CENTERED UNDER SUPPORTED COLUMNS AND WALLS UNLESS SHOWN OTHERWISE IN THE DESIGN PLANS. a 0 R .1 7: r; MW 4.1. REINFORCING STEEL: 4.1.1. REINFORCING STEEL SHALL BE ASTIM A615 I A1185M-04A MIN. GRADE 40, fy = 40 Ksi 4.1.2. LAP SPLICE SHALL BE AS FOLLOWS: #5 BAR 25", #4 BAR 20", #3 BAR 20". 4.1.3. ALL DIMENSIONS PERTAINING TO THE LOCATION OF REINFORCING ARE TO THE CENTERLINE OF EACH BAR EXCEPT WHERE THE COVER DIMENSION IS SHOWN TO THE FACE OF THE CONCRETE. 4.1.4. REINFORCING DETAIL DIMENSIONS ARE OUT TO OUT OF BARS. 4.1.5. REINFORCING MECHANICAL COUPLERS ARE TO DEVELOP 125 % OF THE REQUIRED YIELD STRENGTH OF THE BAR AND ARE TO BE APPROVED BY THE ENGINEER OF RECORD. 4.1.6. DESIGN COVER REQUIREMENTS: C-I-P CONCRETE FORMED AGAINST EARTH: 3- C-I-P CONCRETE EXPOSED TO EXTERIOR: 2- C-I-P CONCRETE NOT EXPOSED: 1 Y2. GROUT FILLED MASONRY: y4" 4.1.7. WELDED WIRE FABRIC (WWF): ASTM A-185 / A 185M-07 4.1.8. DETAIL REINFORCEMENT IN ACCORDANCE WITH ACI 318-11 (STRUCTURAL CONCRETE) ACI 530-11 (MASONRY STRUCTURES) 4.2. CONCRETE: 4.2.1. CONCRETE TYPE MIN. 28 DAY DESIGN (fc) MODULES OF ELASTICITY DESIGN (E) C+P CONCRETE (NORMAL WEIGHT) 2,500 Psi 2,850 Ksi C-1-P CONCRE E (NORMAL WEIGHT) HERNANDO CO. ONLY 3,000 Psi 3,122 Ksi C-1-P GROUT 3,000 Psi 3,122 Ksi 4.2.2. CONCRETE SHALL CONSIST OF 1" MAXIMUM AGGREGATE CONCRETE MIX WITH SLUMP BETWEEN 6"AND 7"AT TIME OF PLACEMENT. SEE SPECIFICATIONS FOR ADDITIONAL CRITERIA. 4.2.3. GROUT SHALL CONSIST OF PEA ROCK (3/8' MAXIMUM AGGREGATE) CONCRETE MIX WITH SLUMP BETWEEN 8" AND 10"AT TIME OF PLACEMENT. SEE SPECIFICATIONS FOR ADDITIONAL CRITERIA. 4.2.4. CONSTRUCTION JOINTS WILL BE PERMITTED 4.2.5. METHOD OF CONCRETE FORMING, PLACEMENT AND CURING SHALL BE CONDUCTED IN ACCORDANCE WITH THE SPECIFICATIONS AS STATED. 4.2.6. EARTH SUPPORTED SLABS (EXCLUDING EXTERIOR WALKWAYS & DRIVEWAYS): 31/2" MIN. THICKNESS W/ MIN. REINFORCEMENT OF 6.0 x 6.0 W/ 1.4 x 1.4 WWF @ MID -DEPTH OF SLAB, FIBER MESH PER DESIGN MIX MAY BE USED I.L.O. WWF @ CONTRACTORS DISCRETION. 4.2.7. CONCRETE PLACEMENT PRACTICES SHALL BE IN ACCORDANCE W/ ALL ACI- MCP 2011 STANDARDS. 4.3. CONCRETE MASONRY: 4.3.1. FILLED CELLS W/ (1) #5 BAR SHALL BE LOCATED PER PLAN. 4.3.2. LOAD BEARING CONCRETE MASONRY BLOCK SHALL BE ASTM C90-06011, TYPE 11 NON -MOISTURE CONTROLLED. 4.3.3. ALL CELLS & CAVITIES BELOW GRADE WILL BE FILLED W/ CONCRETE IN ALL STEM WALLS. 4.3.4. THE AGGREGATE STRENGTH OF THE BLOCK AND MORTAR SHALL BE F'm = 1,500 PSI MINIMUM. 4.3.5. METHOD OF CONCRETE MASONRY PLACEMENT AND CONSTRUCTION SHALL BE CONDUCTED IN ACCORDANCE WITH THE SPECIFICATIONS AS STATED. 4.3.6. MORTAR SHALL BE ASTM C270 TYPE "S" FOR ALL MASONRY CONSTRUCTION. 4.4. STRUCTURAL LUMBER: 4,4.1,1. INTERIOR LOAD BEARING7ALLS SPF #2, fb = 1,312 PSI, E = 1,400 KSI ALL EXTERIOR FRAMING SPF #2, fb = 1,312 PSI, E = 1,400 KSI 4.4.1.2. ALL FRAME WALLS TO BE CONSTRUCTED USING SPF #2, STUD QUALITY OR BETTER 4.4.2. ALL PLYWOOD USED FOR EXTERIOR APPLICATIONS SHALL BE APA RATED STRUCTURAL SHEATHING 15132" EXP 1 OR 7/16' STRUCTURAL 1, U.N.O. 4.4,3. ALL PLYWOOD USED FOR INTERIOR APPLICATIONS SUCH AS SUB FLOORING AND SHEAR WALLS SHALL BE APA RATED SHEATHING EXP 1 U.N.0, 4.4.4. IF OSB BOARD IS TO BE USED IN PLACE OF PLYWOOD IS TO HAVE SIMILAR OR GREATER SECTION PROPERTIES. 4.4.5. ONLY STRUCTURAL LUMBER TO BE USED FOR AN EXTERIOR APPLICATION. WOOD IN CONTACT WITH CONCRETE IS TO RECEIVE A STANDARD GRADE PRESSURE TREATING. 4.4.6. WHEN PRE ENGINEERED TRUSSES ARE CALLED FOR ON THE PLANS THE MANUFACTURER IS TO SUBMIT SHOP DRAWINGS TO THE ENGINEER OF RECORD. 4.4.7. DESIGN, FABRICATE AND ERECT WOOD TRUSSES IN ACCORDANCE WITH THE"DESIGN SPECIFICATION FOR LIGHT METAL PLATE CONNECTED WOOD TRUSSES" BY THE ANSI1TPI 1-2007, BCSI 4.4.8. UNTREATED WOOD SHALL NOT BE IN DIRECT CONTACT WITH CONCRETE. SEAT PLATES SHALL BE PROVIDED AT BEARING LOCATIONS WITHOUT WOODEN TOP PLATES, 4.4.9. ALL EXTERIOR FRAME WALLS SHALL BE STUCCO FINISH- 7/8" STUCCO FINISH PER ASTM C. 926, APPLY 3 LAYERS W/ TOTAL THICKNESS 7/8" OVER METAL LATH. FIRST 2 LAYERS 3/8"THICK EACH. 3RD LAYER 118" THICK 4.4.10. INSTALLATION OF EXTERIOR LATHING & FRAMING SHALL COMPLY TO ASTM C 1063 PER FLORIDA CODE R706.6.1 4.5. FASTENERS AND TIE DOWNS: 4.5.1. FASTENERS AND TIE DOWNS SHALL CONSIST OF BUT ARE NOT LIMITED TO: SHAPES, ANGLES, CHANNELS: ASTM A36/36M 05 Fy = 36 Ksi ROUND METAL PIPE: ASTM A53, GRADE B Fy = 35 Ksi SQUARE METAL TUBING: ASTM A500, GRADE B Fy = 46Ksi HIGH STRENGTH BOLTS: ASTM A325 MACHINE BOLTS: GALVANIZED ASTM A307 4.5.2. SHEET METAL ACCESSORIES SHALL CONFORM TO: Fy = 33KsiWITH G90 GALVANIZED COATING IN ACCORDANCE WITH ASTM A525-87. 4.5.3. NAILS SHALL CONSIST OF: COMMON WIRE NAILS WITH MINIMUM DIAMETER AS FOLLOWS: 8d = 0.131", 10d = 0.148", 12d = 0.148", 16d = 0.162". 4.5.4. ALL FASTENERS AND TIE DOWNS EMBEDDED IN CONCRETE OR USED IN AN EXTERIOR APPLICATION ARE TO RECEIVE AN ANTI -CORROSIVE COATING BY MANUFACTURER PRIOR TO INSTALLATION. 4.5.5. ALL FASTENERS AND TIE DOWNS ARE TO PROVIDE THE UPLIFT CAPACITY CALLED FOR IN THE PLANS ARE A MINIMUM. 4.5.6. ALL FASTENER TIE DOWNS, BEAM HANGERS, JOIST HANGERS, AND FLOOR TRUSS STRAPPING ARE TO BE INSTALLED IN ACCORDANCE WITH THE PLANS AND SPECIFICATIONS, 4.5.7. CONCRETE EMBEDDED'J'BOLTS USED FOR UPLIFT ARE TO BE WET SET PRIOR TO INITIAL SET OF THE CONCRETE, SPACING AND ALIGNMENT ARE TO BE IN ACCORDANCE WITH THE DESIGN PLANS, U.N.O. ALTERNATES TO 7' BOLTS ARE NOTED ON PLANS. 4.5.8. CONCRETE EMBEDDED TIE DOWNS USED FOR TRUSS AND WALL UPLIFT ARE TO BE PLACED AROUND EMBEDDED REINFORCING PRIOR TO OR WHILE PLACING GROUT. 4.6. MICRO -LAM LUMBER: 4.6-1. MICRO -LAM STRESS GRADES SHALL PROVIDE THE FOLLOWING MINIMUM PROPERTIES: E 2,000,000 PSI Fb 2,950 PSI Ft 1,850 PSI Fc: 500 PSI (PERPENDICULAR) Fc 2,700 (PARALLEL) 4.7. STEEL: Fv 285 PSI 4.7.1. INSTALLATION OF ALL STEEL TO BE PERFORMED BY AN EXPERIENCED, QUALIFIED STEEL ERECTOR. 4.7.2. FABRICATE AND ERECT ALL STRUCTURAL STEEL IN ACCORDANCE WITH A.I.S.C. "SPECIFICATION FOR THE DESIGN, FABRICATION, AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS". 4.7.3. STRUCTURAL STEEL: ASTM A36/36M 05. 4.7.4. STEEL TUBING: ASTM A500, GRADE B. 4.7.5. WELDED CONNECTIONS: E70XX ELECTRODES, MINIMUM SIZE FILLET WELDS 3/16", AWS CERTIFIED WELDERS. CERTIFICATION PAPERS TO BE SUBMITTED UPON REQUEST. 4.7.6. WHERE STEEL BEAMS ARE CONTINUOUS OVER COLUMNS, PROVIDE WEB STIFFENER PLATES ON EACH SIDE OF THE WEB, OF A THICKNESS EQUAL TO BEAM FLANGE THICKNESS, LOCATED AT THE CENTER LINE OF THE TUBE COLUMN. 4.7.7. THE STEEL FRAME IS "NON -SELF SUPPORT] NG". ADEQUATE TEMPORARY SUPPORT SHALL BE PROVIDED BY THE CONTRACTOR UNTIL REQUIRED CONNECTIONS OR 4.8. SOIL ELEMENTS ARE IN PLACE. 4.8.1. MINIMUM SOIL BEARING PRESSURE CAPACITY OF 2000 PSF. FOUNDATIONS HAVE BEEN DESIGNED WITH THE MIN. CAPACITY OF 2000 PSF 4.8.2. ALL SOIL IS TO BE CLEAN & POISONED FOR TERMITES PER FBC 5th ad. (2014), RESIDENTIAL SECTION R318. 4.8.3. SOIL IS TO BE COMPACTED TO 95% MODIFIED PROCTOR AS DEFINED BY ASTM D 1557-02EO1 TERMITE PROTECTION - CONTRACTOR TO USE (1) OF THE TREATMENTS BELOW Borate / Boracore treated lumber Soil Chemical Barrier Method Other treatment - Must specify proposed method and submit documentation, which substantiates the proposed method, is an approved termite protection system or method. OR CHEMICAL SOIL TERMITE TREATMENT IS USED 1. FRC R318. 1 -"A permanent sign which identifies the termite treatment provider and need for re-i6spection and-treartment contract renewal shall be provided. The sign shall be posted near the water heater or electric panel" 2. Condensate and roof downspouts shall discharge at least V-0" away from the building side walls. 3. IrriArtiorVs Tdnld, stems includin%all risers and sp y hea s she I n t be installed w hin V-0" of the building side wall. 4. FRC R3118.7- To provide for inspection for termite infestation between wall covering and final earth grade shall not be less than 6 inbhes. Exception: Paint or decorative cementitious finish less than 5t8" thick adhered directly to the foundation wall. 5. FRC R318.1.1 - Initial treatment shall be done after all excavation and backfill is complete. 6. FRC R318.1.2 - Soil disturbed after the initial treatment shall be retreated including spaces boxed or formed. 7. FPC R318.1.3 - Boxed areas in concrete floors for subsequent installation of traps etc., shall be made with permanent metal or plastic forms. Permanent forms must be of a size and depth that will eliminate the disturbance of soil after the initial treatment. 8. FRC R318.1.4 - Minimum 6 mil vapor retarder must be installed to protect against rainfall dilution. If rainfall occurs before vapor retarder placement, retreatment is required. 9. FRC1918.1.5;9%?,reteove our and mortar along the foundation perimeter must remov ore extepc r soil treatment. 10. FRC R318.1.6 - Soil treatment must be applied under all exterior concrete or grade within V-0" of the structure sidewalls. 11. FIRC R318.1.6 - An exteripir vertical chemical barrier must be installecI a�er I construction is complete, including landscaping and irrigation. Any soil isturbed after the vertical barrier is applied, shall be retreated, 12. FRC R318.1 - All buildings are required to have pre -construction treatment. 13. FIRC R318.1 - A certificate of compliance must be issued to the building department b a licensed pest control company before a certificate of occupancy will ba issued. Tge certificate of compliance shall state: "The building has received a complete treatment for the prevention of subterranean termites. The treatment is in accordance with the rules and laws of the Florida Department of Agriculture and Consumer Services". 14. FRC R318.6 - After all work is completed, loose wood and fill must be removed from below and within V-17' of the building. This includes all grade stakes, tub trap boxes, forms, shoring or other cellulose containing material. WORST CASE DESIGN PRESSURE TABLE BUILDING DATA WIND SPEED (ULTIMATE) 140 MPH WIND SPEED (ALLOWABLE) 108 MPH WIND EXPOSURE - 'C" (FRC R301) INTERNAL PRESSURE COEFFICIENT= 0.18 ENCLOSED BLDG) BUILDING CATEGORY = 11 DESIGN WIND PRESSURE: (COMPONENT AND CLADDING) WORSTCASE (10 SF - END ZONE) # END ZONE IS ONLY WITHIN V-0" OF ALL EXTERIOR BUILDING CORNERS WINDOWS AND DOORS 140 MPH + 29.7 PSF / -39.6 PSF (END) U.N.O. CONSTRUCTION + 29.7 PSF / -32.2 PSF (INTERIOR) U.N.O. TYPE: 5B GARAGE DOORS (V = 140 MPH) SINGLE 90 +26.3 PSF / -29.8 PSF DOUBLE 160 +25.2 PSF / -28.1 PSF NOTE: THE WIND PRESSURES LISTED ABOVE ARE ALLOWABLE PRESSURES. NOTE: IT IS THE CONTRACTORS RESPONSIBILITY TO REVIEW ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. FLORIDA DESIGN SOLUTIONS, INC. IS RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF THIS PROJECT ONLY. ANY DISCREPANCY BETWEEN FIELD CONDITIONS, OTHER DESIGN PROFESS IONALS'SHOP DRAWINGS, CONTRACTORS' BUILDING METHODS, AND THESE SIGNED AND SEALED DRAWINGS MUST BE BROUGHT TO THE ATTENTION OF FLORIDA DESIGN SOLUTIONS, INC. PRIOR TO THE COMMENCEMENT OF CONSTRUCTION. NOTE: GYPSUM BOARD MAY BE INSTALLED USING GWB54 NAILS TO SET IN PLACE. FIELD FASTENING SHOULD BE TYPE "W" 1)/4" DRYWALL SCREWS AT 12" O.C. FOR CEILINGS AND 1Y811 DRYWALL SCREWS AT 12" O.C. FOR WALLS. ALL ENDS AND EDGES OF WALLBAORD SHALL OCCUR OVER AND BE SCREWED TO SUPPORTS. MAXIMUM SCREW SPACING AT ENDS (EDGES IN VERTICAL APPLICATION) SHALL BE 6" O.C. AT EACH SUPPORT. MINIMUM SCREW NAIL DISTANCEFROM EDGE SHALL BE 3/8". THIS SHALL APPLY TO BOTH CEILING AND WALL INSTALLATION. DRYWALL SHIMS SHALL BE USED ONLY WHERE NECESSARY. OPENINGS CUT FOR OUTLETS, SWITCHES, ETC, SHALL BE OF A TOLERANCE THAT CAN BE COVERED ADEQUATELY WITH NORMAL SWITCH PLATES AND COVERS WITHOUT ADDITIONAL TAPING OR CAULKING. DRYWALL SHALL NOT BE INSTALLED WITHOUT PROPER BACKING. NOTE: ALL HEADERS, BEAMS, ETC ARE TO BE SYP #2 OR BETTER AND OR MICROLAM AS INDICATED ON THE DRAWINGS AND CAN NOT BE REVISED. 0 LOU Z 0 -8 Z (0 W Z C 4--J Lu U LU 0 V) F- E 0 C) 04 0) ce) LU F_ E 8 aim 0 M2 c.4 oo,, -) 4-1 U. 00 "s 0 < 0 Mr), 0 C. < 61 -A I c I -&--% rl� �,,o VV Z 4-2 6 -,-.= ,� LA_ . (A"L* . low, 4.1 lu W VIC ZG M o, SUP -r- :2 - c-F L 91151 LLI E` U1 To the best ofthe Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code Sth Edition (2014) Residential, Engineer's signature and seal Is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. C� 0 Z 0 " :!=! C:) V) = kD M CD C) 4-J V) (0 Lr) U) 0 - Ul C>L LL F- 111:1� U 0_ 00 Z Z 3i E Z M C:� F- WLU _j C:) 8 U-1, CLU LU Q) Ln F- 0 I Z Z Lr) 0 U u>1 0 U_ l:2 P cr_ F- g PIN U) 9 N Z Z V-11 6-'� 6 1 LU Ln -, I Lij X < Lij Z m 00 M 000 Ln Z Z t- U LU :10 rn lr.� V-1 :5 10- 1 V) I SCALE AS NOTED DATE 2/24/2014 TECH: MJAMES VERSION NO 10 SHEET NO. SN 101-011 TANK -LESS W/H CORNEROF /7 H C G HOME GARAGE SIDE 0 0 0 51-011 STUB -OUT FOR 7� = b GAS METER 01 0 u.) 0 C,4 MEASUREMENTS ARE FROM FINISHED FLOOR ROUGH -IN GAS TO RIGHT (ALWAYS) - 12" OFF -CENTER ROUGH -IN ELECTRIC TO LEFT (ALWAYS) - 12" OFF -CENTER GAS CONNECTION DETAIL "ONLY APPLIES TO HILLSBOROUGH AND PASCO COUNTY" RAFTER SPAN TABLE MEMBER SIZE AND SPACING MAXIMUM LENGTH MEMBER CONNECTIONS* 2" X 4" @ 16" O.C. 71-511 (2) 16d TOENAILS 21t X 6" @ 16" O.0 101-811 (2) 16d TOENAILS 2" X 8" @ 16" O.C. 13'-9" (3) 16d TOENAILS 2- X 10" @ 16" O.C. 16-5-1 (1) USP HTW20 OR (3) 16d TOENAILS 2" X 12" @ 16" O.C. 191-311 (1) USP HTW20 OR (4) 16d TOENAILS 2" X 4" @ 24" O.C. 61-1 (2) 16d TOENAILS 2" X 6" @ 24" O.C. 81-6" (2) 16d TOENAILS 2" X 8" @ 24" O.C. 111-01. (2) 16d TOENAILS 2" X 10" @ 24" O.C. 131-011 (3) 16d TOENAILS 2" X 12" @ 24" O.C. 151-411 (1) USP HTW20 OR (3) 16d TOENAILS TOENAIL CONNECTIONS DESIGNED FOR SHEAR ONLY (i.e. RAFTER TO RIDGEBEAM). SOUTHERN YELLOW PINE, 55 PSF LOADING _J ROOF DIAPHRAGM NAILING SCHEDULE RIDGE LINE . . . . . . . . . . . . + + + + 4 + + + + + + 9- + . . . . + + + + + + + + + + + + + + + + 4 4 + + + + + + + + + + + + 4- (TYP.) + + V-0" ------ —7 +/ 6'-0" + f + + + + 4 + + + + + + + + N + + + + + + + + + + /++ + + + + + + + 1+ + + + + + + + + + + . . . . . . + + + + 9 . . . . . . + . . . . + . . . . . . . . . . . . . . + + +N+ I. + + + 4. 4. 4- + 15/32" CDX PLYWOOD OR 7/16" OSB '­RIDGE LINE 140 MPH (ult)3 SECOND GUST EXPOSURE "C" WIND ZONE 140 MPH (ult) 3 SECOND GUST EXPOSURE "C" WIND ZONE 8d RING SHANK NAILS @ 6" O.C. & 8d RING SHANK NAILS @ 6" D.C. EDGES & + + 4" O.C. @ GABLE END WALL OR GABLE TRUSS 8d RING SHANK NAILS @ 6" O.C. INTERMEDIATE + + 0.113 INCH NOMINAL SHANK DIAMETER 0.113 INCH NOMINAL SHANK DIAMETER RING DIAMETER OF 0.012 OVER SHANK DIAMETER RING DIAMETER OF 0.012 OVER SHANK DIAMETER 16 TO 20 RINGS PER INCH 16 TO 20 RINGS PER INCH 0.280 INCH FULL ROUND HEAD DIAMETER 0.280 INCH FULL ROUND HEAD DIAMETER 2 INCH NAIL LENGTH 2 INCH NAIL LENGTH NOTE: r FOR 8d RING SHANK NAILS 0.1 13x 2x 3/8" RING SHANK COIL GUN NAILS MAY BE USED 1) SEE STRUCTURAL NOTES FOR SHEATHING SPECIFICATIONS AND WIND SPEED. 2) END JOINTS OF THE ROOF SHEATHING SHALL BE STAGGERED AND OCCUR OVER FRAMING MEMBER. 3) SCHEDULE ASSUMES SHEATHING IS FASTENED DIRECTLY TO SOUTHERN YELLOW PINE OR DOUGLAS FIR OR BETTER. IF ROOF FRAMING CONSISTS OF A LESSER GRADE OF LUMBER, CONTRACTOR MUST CONTACT ENGINEER OF RECORD FOR ALTERNATE NAILING PATTERN. Backer and Filler Block Dimensions BC18JOist Backer Block Thickness Filler Block Thickness Series - 3/4" or 7/8" 5000s 1.8/1.7 wood panels Two 3/4" wood panels or 2 x 1-1/8" or two 1/2" 6000s 1.8/1.7 wood panels 2 x — + 5/8" or 3/4" wood panel 1-1 /8" or two 1/2" 6500s 1.8/1.7 wood panels 2 x — + 5/8" or 3/4" wood panel 1-1 /8" or two 1/2" 602.0 wood panels 2 x — + 5/8" or 3/4" wood panel 902.0 2 x — lumber Double 2 x — lumber DOUBLE JOIST CONSTRUCTION (Not required if both loaded equally from above) Filler blocking 1/8" gap 1) Support back of web during nailing to prevent damage to web -flange connection. 2) Block solid between joists for full length of span. 3) Leave 1/8" gap between top of filler blocking and bottom of top flange. 4) Place joists together and nail from each side with 2 rows of 1 Old nails 2x : CONTRACTOR TO PROVIDE 2x TO FILL THE HEIGHT at 12" o.c., clinched when possible. Stagger rows from opposite OF THE JOIST ASA REQUIRED LEAVING Y8" GAP @ TOP sides by 6". DOUBLE JOIST CONNECTION N.T.S. FILL CELL-\ STD. 900 HOOK F BOND BEAM 1 LU CONT. #5 STD. 900 CONT. #5 > HOOK BAR BAR F-7— I #5 CONT. FROM FOUNDATION TO HIGHEST BOND BEAM BOND BEAM STEP SCALE: N.T.S. INTERIOR/EXT WALL SEE PLAN FOR MORE INFO CONT. BASE PLATE BEARING COLUMN FLOOR SEE PLAN FOR REQ'D SHEATHING PER PLAN COLUMN AND CONNECTION TJ I TO BE CUT TO ALLOW FOR BLOCKINGITJI MASONRY WALL OR INTERIOR BRG. WALL TJI PER PLAN OTHERWISE SOLID BLOCKING TO MATCH # OF 2nd FLOOR Solid block all posts from ST LIDS above to bearing below, SECTION @ INT. BRIG. WALL N.T.S. 1/8" min 2" ' ) Small gap 2" min. max. 4" max. Web Stiffener Fastener Schedule Joist aring Location Series End I Intermediate epth -1/2"_� 2-8d I BCI 5000sa 2-8d 2i-ad 11-7/8" 2-8d 14" 2-8d 5.8d Clinch nails - 9-1/2" 2-8d 2-8d when BC16000se 11-70'_ 2-8d 3-8d possible BCI 6500se— 14" 2-8d 't-M 16 2-8d 6-8d 77 1 1-7/8" 2-8d 3-8d ---------- BCI 60s@ W 2--8d 5-8d Tight fit 11 2-8d 6-8d �11-7La!_ 3-1 6d 3_-._1 6d­ 2x4/PIywood/OSB web stiffener 2" min- BC190se 14" 5-16d 5-16d required when indicated or 4" max. _16" 6-16d 6- _-1 6-d Hangers with side nailing. Hangers with sides not containing WEB STIFFENER top flange of joist. Birdsmouth cuts. N.T.S. Under 2nd floor column w/ loads higher than 15001b. U� M 5/8,11 THF BOL R TRUSS 'OP PLATE I.0 TYPICAL USP MUGT15 TO BUILT-UP COLUMN DETAIL TYPICAL HUS INSTALLATION AIN. EMBEDMENT SCHEDULE FOR AND QUANTITY )F FASTENERS HTA 20-18 HTA 20 INSTALLATION @ MID SPAN LOCATION OF SECOND RT16 NOTE: UPLIFT VALUE IS BASED ON S.P.F. USP RT16 USING 16-8d x1 1/2" NAILS UPLIFT = 1030# TYPICAL RT16 INSTALLATION TYPICAL HTA 20-18 HTA 20 BLOCKING PANEL, INTERIOR INSTALLATION TYPICAL MTW INSTALLATION SQUASH BLOCKS AT INTERIOR Boise Joist Blocking Vertical load transfer =1 900 plf max. along bearing wall BEARING Use 3" (1 Od) nails at 6" o.c. Required on interior walls: - for vertical load transfer Plumbing Load aring walls when load beefing - for lateral support when joists Vertical load transfer =1 900 plf max along load bearing wall. Load bearing wall must stack meet over wall, or wall stacks directly over wall or LJ beam below Load bearing wall must stack over over squash=20 blocks and *Non -stacking walls wall or beam below.* blocking and wall or beam below.* require additional Joist When joists meet over wall, provide consideration. Check k L' 0 w 'Jou he local building W I -Joist can be offset 13/4" minimum bearing for each. code for appropriate. PLUMBING LINE up to 3" to avoid details in One 10d box vertical plumbing areas=20 of high or--20 sinker TOP (2) #5's x 4' 011 lateral load. nail each side 3" max CENETERED @ PIPE PVC OR SCH40 SLEEVE PENETRATION at bearing. A/C CHASE 4" PVC JOISTS OFFSET SLEEVE THRU STEM N.T.S. WALL 11r. 4 rovi e a equate bearing Use 1 Odx3" nal Is at 6"o.c. for all joist A 4. .4 for each lapped joist. blocking panel *Non -stacking walls 00 Squash block Od nails require additional consideration. SECTION INT. BRIG. WALL FINI.(�H GRADE (2x4 minimum) N.T.S. Bearing wall, Versa -Lam LVL or 0 Glulam Beam MINIMUM SPACING 2x GREATEST KNOCKOUTS) ALLOWED D DIMENSION OF LARGEST HOLE IN BEARING ZONES NOCKOUT EXEMPTS) (see table below) D it (see table below) DO NOT cut, notch I I or drill flanges 1 maim 01*17'.7- A ROUND HOLE MAY q CANT, LEVER BE CUT ANYWHERE IN THE WEB. PROVIDE AT LEAST 3" OF CLEARANCE FROM OTHER HOLES MINIMUM DISTANCE FROM SUPPORT, LISTED BELOW, IS REQUIRED FOR ALL HOLED GREATER THAN DO NOT CUT HOLES LARGER THAN %" ROUND IN CANTILEVERS. 8 1 -0. -1. 1 �-2" 1 �-2" 11-37 1 '-3- 1 �-1 1" 2 '4" 7-9" y 16" joist 12 V-0" V-1 " 1 �-2" V-2" V-3" 1!-9" 2�4 1" 3�-7" 4'-2" n (ft) 16 V-0" V-11" V-2" 1 �-2" V-7" 2!-5" 3'-10" 4'-9" 5'-7" 20 V-10i" V-1 " V-2" V-2" 2'-0" 3'-0" 4'-10" 5!-11" W-11' 7!-11"18'-11"1 24 V-0" , V-11"F 17 _2" V-3" 2'-5- 3'-7- 4!-9- 5'-10" 7!-2" 1 8'-4" W-113" 11 O�-9" NOTES: 1. JOISTS MUST BE PROPERLY DESIGNED TO MEET BUILDING CODE REQUIREMENTS. 2. TABLE IS FOR UNIFORMLY LOADED MAXIMUM LOADS OF 40 PSL(LIVE) AND 15 PSF (DEAD) ON SIMPLE SPAN APPLICATIONS ONLY. 3. REFER TO JOIST SPECIFIER GUIDE FOR INSTALLATION AND OTHER INFO. 4. SELECT A TABLE ROW BASED ON JOIST DEPTH AND THE ACTUAL JOIST SPAN ROUNDED UP TO THE NEAREST TABLE SPAN. SCAN ACROSS THE ROW TO THE COLUMN HEADED BY THE APPROPRIATE ROUND HOLE DIAMETER OR RECTANGULAR HOLE SIDE, USE THE LONGEST SIDE OF A RECTANGULAR HOLE. THE TABLE VALUES IS THE CLOSEST THAT THE CENTERLINE OF THE NEAREST SUPPORT. 5. THE ENTIRE WEB MAY BE CUT OUT. DO NOT CUT THE FLANGES. HOLES APPLY TO EITHER SINGLE OR MULTIPLE JOISTS IN REPETITIVE MEMBER CONDITIONS. 6. FOR MULTIPLE HOLES, THE AMOUNT OF UNCUT WEB BETWEEN HOLES MUST EQUAL AT LEAST TWICE THE DIAMETER (OR LONGEST SIDE) OF THE LARGEST HOLE. 7. %2" ROUND KNOCKOUTS IN THE WEB MAY BE REMOVED BY USING A SHORT PIECE OF METAL PIPE AND HAMMER. 8. HOLES MAY BE POSITIONED VERTICALLY ANYWHERE IN THE WEB. THE JOIST MAY BE SET WITH THE %" KNOCKOUT HOLES TURNED WITHER UP OR DOWN. 9. THIS TABLE WAS DESIGNED TO APPLY TO THE DESIGN TO APPLY TO THE DESIGN CONDITIONS COVERED BY TABLES ELSEWHERE IN HIS PUBLICATION. USE THE BC CALC SOFTWARE TO CHECK OTHER HOLE SIZES OR HOLES UNDER OTHER DESIGN CONDITIONS. IT MAY BE POSSIBLE TO EXCEED THE LIMITATIONS OF THIS TABLE BY ANALYZING A SPECIFIC APPLICATION WITH THE BC CALC SOFTWARE. HOLE CUTTING CHART N.T.S. Backer block (12" wide min.) Nail with 10- 1 Od nails. Install tight to top flange. Joist hanger Filler block. Nail with 10-1 Od nails. QI Backer block required where top mount hanger load exceeds 250 lbs. Install fight to top flange. 1/4"-2" gap_�__� zZI/ cker Block Be "Top Mount" "Face Mount" Backer block shall be tight Backer block shall be tight to bottom of top flange with to top of bottom flange with 1/4"-2" gap at top of bottom 1/4"-2" gap at bottom of top flange. flange. eb stiffner as Web stiffeners are not required when top required if hanger flange is laterally supported by joist hanger. doesn't meet height requirements 0.6 X Joist depth I -JOISTS BUCKETS N.T.S, SLEEVE THRU STEM—/, 9 t - , . SEE PLAN FOR--' FOUNDATION INFO STEM FOUNDATION GRADE a A A REINF. SEE PLAN A (2) #5 REBAR A/C CHASE 4" PVC SLEEVE THRU FOOTING MONO FOUNDATION TYP. FND. PENETRATIONS SCALE: N.T.S. N SEE FND. PLN I SIZE & R PIPE VERTICAL THRU FND. PVC OR SCH40 SLEEVE TOP (2) #5's x 4'-0" CENETERED @ PIPE PENETRATION PLUMBING LINE —4— L 4 A SEE FND. PLN. SIZE & REINF. PIPE PERPENDICULAR TO FND. TOP (2) #5's x 4'-0" CENETERED @ PIPE PENETRATION A SEE FND. PLN. SIZE & REINF. PVC OR SCH40 SLEEVE PLUMBING LINE 4 . A4 !�? a (D z a) z z < 1 W11111111111111 CL z U0 (D Q) U3 LU 0 U — LU 0 V) Lh E 00 CO r- 0 0 C"n ce) ce) E as 10 'S C) I29 u. ED 1 00 CO CL < 0 co LO R:s I< Ci A I N*"' D c z (,,) C> 8 U_ A! k 0 (Q. 10M '2 0 q. -_ \ .9 1 '0 0 0 0) , Askov0 To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code Sth Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. C:) C:) z N 0 w 1­4 41-� C) 1 53 t.0 On M CD 0 N V) q Ln z 0 (V - Ln LL U oo E z § M z 0 _J 0 LULU mi z Lu� U 480, z Y U) > Ln LLJ 0 z Ln 0 cc U p F- 88- 0 =3 V, P 1H 0", 'd f-4 Cn < z 14r N WJ � 'I z LLJ T-4 Ln T__I LU � U� CY LL I < X < z 0; 5 00 fri 100 kD In Z Z t V) z 0 0 r1l 1 ­1 10- I SCALE AS NOTED DATE 2/24/2014 TECH: MJAMES VERSION NO 10 SHEE7 NO. SN 1 FOR UNDERLAYMENT REQUIREMENTS SEE R905. I - 1 12 7TTYP') VARIES INSU 5/8" OR 1/2" HIGH ­-` STRENGTH CEILING BOARD PER CODE (OR 5/8" GYP. TYPE "X" @ GARAGE W/A HABITABLE ROOM ABOVE) W/DRYWALL SCREWS @ 7" O.C. CEILING & 8" O.C. WALLS INSULATION PER CHART ON FLOOR PLAN 1x2 P.T. HORIZONTALJ NAILER STD. 90-HOOK (SEE DETAIL v (1) ROW 2x BLOCKING @ MID 2x #2 SPF STUDS HGT. FOR WALL HGT. !� 8,-6,,. (2) @16" O.C. W/ (2) ROWS 2x BLOCKING @ 3rd FITS 161 TOENAILS T & B 'OR WALL HGT. > V-13". 1/2" GYP. WB (MIN.) @ GARAGE SIDE IF APPLICABLE. 2x P.T. PLATE 1/4" DIA. X 3 1/4" TAPCONS @ 24" O/C & @ 6" MAX FROM END OF 2 x PLATE (1) LAYER TYPE 11 (#30) (2) #5 CONT ON 3- 6 x 6 W1.4 x W1.4 UNDERLAYMENT FOR ROOF CHAIRS (TYP.) WWF OR FIBERMESH Cl) PITCH >4:12 L 1 1, . . v (2) LAYERS TYPE I OR TYPE 11 Y A V (#15 OR #30) UNDERLAYMENT IIA .. . . . I> FOR ROOF PITCH 4:12 OR LESS. 'AfM- PRE ENGINEERED WOOD Ir TRUSS @ 24" O.C. U.N.O. VS HURRICANE ANCHOR @ EACH ov, ;:TRUSS (SEE UPLIFT SCHED.) W/ METAL PL. UNDER EA. TRUSS MOISTURE BARRIER TYPICAL INTERIOR BEARING ,,_SHINGLE ROOF 7/16" O.S.B. MIN. SEE ROOF WALL W/OUT UPLIFT G� NAILING SCHEDULE ON SHT. SEE TYP. WALL SECTION SCALE: 3/4"=:1'-0" � �3 SN1 ELEV, VARIES FOR ADDITIONAL SLAB INFORMATION. 'jALUMINUM DRIP EDGE ,,ALUMINUM FASCIA 2x SUB FASCIA 5/8"OR 1/2" HIGH STRENGTH �-TRUSS BOTTOM CHORD OR 2x4 BLOCKING 5/8"OR 1/2" HIGH STRENGTH - (U.N.O.) (OR %" GYP. TYPE "X" @ V W/ 2-16d TOE NAILS @ EACH END (U.N.O.) (OR %" GYP. TYPE "X'@ GARAGE W/A HABITABLE ROOM ABOVE) S EE UPLIFT SCHEDULE FOR UPLIFT GARAGE W/A HABITABLE ROOM S.P.F. DOUBLE CONNECTIONS. PROVIDE (1) USP HTW20 WHEN ABOVE) TOP PLATE TRUSS ALIGNED WITH STUD BELOW S.P.F. DOUBLE 8"x8"x16" NOMINAL BLOCK WITH TOP PLATE 3/8" MORTAR BETWEEN COURSES USP SPT24 4L CONNECTOR "x S.P.F. (OR EQUAL) STUDS @ 16" O.C. U.N.O. USP SPT24 1/2" CDX PLYWOOD OR 7/16" O.S.B. CONNECTOR -A SHEATHING REQ'D. FOR ALL EXTERIOR OR SHEAR WALLS AS 1) ROW 2x BLOCKING @ MID HGT. FOR WALL HGT. < V-13". (2) ROWS 2x BLOCKING @ 3rd PTS E­­-JE INDICATED ON THE PLAN. ATTACH FOR WALL HGT. > 8'-6". SHEATHING W1 8d COMMON NAILS @ 4" O.C. @ BOUNDARIES, 6" O.C. @ INSULATION PER CHART ON FLOOR PLAN 3/8" MORTAR BETWEEN EDGES, AND @ 12" O.C. @ FIELD TRUSS BOTTOM CHORD OR 2x4 BLOCKING W/ 2-16d TOE NAILS @ EACH END SEE UPLIFT SCHEDULE FOR UPLIFT CONNECTIONS. PROVIDE (1) USP HTW20 WHEN TRUSS ALIGNED WITH STUD BELOW -2"x S.P.F. (OR EQUAL) STUDS @ 16" O.C. U.N.O. ---(1) ROW 2x BLOCKING @ MID HGT. FOR WALI�-HGT. < T-13". (2) ROWS 2x BLOCKING @ 3rd PTS FOR WALL HGT. > T-16". --4NSULATION PER CHART ON FLOOR PLAN OLMID Ck DLUkjr\ 5/8­ x 10" "J" BOLT @ 24" O.C. W/ or or 122 1 vr% 5/8" x 10" "J" BOLT @ 24" O.C. W/- or or 11,22 CONNEC I OR 2"0016" PLATE WASHER (TYP.) 704/16" PLATE WASHER (TYP.) ELEV. 0'-0" (ALT- 1/2"xl 2" TITEN HD @ 24" x P.T. BOTTOM PLATE (ALT: 1/2"xl 2" TITEN HD @ 2411 x P.T. BOTTOM PLATE IE AK O.C.'OR 5/8"x10'WEDGE ANCHOR O.C. OR 5/8"x10'WEDGE ANCHOR 4 kF.F. @ 24" O.C.) 2@1 x 6 W1.4 x W1.4 @ 24" O.C.) 21 6 x 6 W1.4 x W1.4 , . I - :::�L 31/2"MIN. WWF OR FIBERMESH 3 1/2" MIN. WWF OR FIBERMESH 4 4 4 4 \4_L ELEV, 4-3 1/211 4 4 A F . . V� 4 4 A.F.F. 0; 1 L -F J L -7 4 2x4 CON ILL T3" T� 1 �/2 (nn 4 2" 4 1 A 4 4 4� z 3 M in.) c\1 A 00 4 4 4 w (311/21"(rnin),-4.1. (31/2"(min.). GARAGE DEPTH VARIES I I L ­7 4" w`� 44 (2) #5 CON (2) #5 CO T. 4" 1'4" 8" T. U.N.O. MIN. U.N.O. GARAGE SLAB AT STEP rB-"� TYPICAL BEARING WALL (ED STEP I@ SHEARWALL ("-C� TYPICAL BEARING WALL @ STEP K`Cc� SCALE: 3/4"=V-0" \, S3 _) "SHEAR WALL" SCALE: 3/4"=V-101" 1\ S3,) SCALE: 3/4"=V-0" '\_S3.,,) 1/2" OR 7/16" OSB MIN. PLYWOOD SHEATHING - NAILED W/ 8d COMMON NAILS @ 4- O/C Iz U. /,-2x S.P,F. S S 16" O.C. BOUNDARIES, 6" O/C EDGES, AND 12" O/C FIELD. EE SOFFIT ­d = -. --u - -- 2x STUD SHEAR WALL REQUIRES 2x BLOCKING @ SEAMS. SHEET LOAD BEARING OR - 1-11 10s, v0s. 8"x8"X16" KNOCK -OUT 8" C M U kt) r%vvvo Ur 4X DLV%.,r\11'4%J I$W x STUDS @ 16" O/C NOTE: BLOCK W/ 1 #5 CONT. TUD ULATION PER CHART ON FLOOR PLAN SEE SECTION C/S3 FOR r2, ADDITIONAL INFORMATION FILLED SOLID W/GROUT EXTERIOR WALL THIRD POINTS 7/8" STUCCO FINISH PER ASTM C. 926 APPLY 3 1"XPT S #5 VERT. IN FILLED CELL 7/8" OVER MI OT L J\' SEE CC/S3 OR A E �� W G/S3 FOR ANCHOR 3 ETA A H, F�R T 2 AYERS 3/8" THICK EACH. CONTINUOUS TO FOOTER BELOW 90 ROOK DETAIL QDAr1C AKIPUAN 5/8" x 10" "J" BOLT @ 24" O/C W/ 2"X 3/16" LL T S L USP SPT22 CONNECTOR M 8" C.M.U. TYPICAL BOLTINFO. 5/8'14" "J" BOLTS BOLT PLATE WASHER TYPICAL P3RD LAYER /8 THICK. K.O. BLOCK (IF NO UP LIFT ON @ 24" O.C. VERT. OR //_USP SPT22 @ EA. STUD 2x P.T. PLATE "S" MORTAR WALL SEE GG/S3) 5/8" x 6" EPDXY BOLT OR 11 11 MIN. 2500 PSI CONCRETE SLAB W/ FINISH 1x2 PT WD FURRING @ 24" O.C.--// H I N�� 1/2"GYPSUM WALLBOARD-��­ (1) #5 VERT. IN FILL U.N.O. CELLS(SEE FOUNDATION PLAN FOR LOCATIONS) 1x4 P.T. BASE NAILER 4"x4" INSPECTION 3 1/4" BASEBOARD PORT AT EACH FILLED CELL TYPICAL MIN. 2500 PSI CONC. LAB AT GARAGE CONTRACTOR MIN PSI MAY VARY PER TO CUT BLOCK OR POUR MUNICIPALITY. CURB DUE TO SLOPE CONCRETE SLAB W/ 6X6 /-NOTE:EXTEND W1.4XW1.4 WWF OR DECO FINISH 4" to 6" "FIBERMESH" BELOW GRADE ;0 ce) 6 MI VAPOR z BARRIER I> 4 COMP. SOIL. (COMPACTED TO 95% MODIFIED PROCTOR ASTM D1557) MIN. CLR. (2) #5 REBAR CONT.--// ON 3" CHAIRS TYP. 4" V-4" STD. 90 HOOK (SEE U.N.O. DETAIL) -TYPICAL WALL SECTION rA SCALE: 3/4" = V-01" ��3� OPT: DEPRESS SLAB 5 Y2" DEEP AND 6" BEYOND DOOR TO RECEIVE PAVERS/ DRIVEWAY BLOCK WALL BEYOND CONCRETE SLAB 14" O.H.D. RECESS ERS� T K PAV L k� M 41' SEE A/S3 OR J/S6 FOR REINF. INFO, MIN. CLEARANCE 1'�" (1 STORY) V-8" (1 STORY w/ DEPRESSED SLAB OPT.) 1 'j8" (2 STOR ) GARAGE DOOR SLAB RECESS SEE TYP. WALL SECTION FOR SCALE: N.T.S. �, �3 ADDITIONAL INFORMATION. (6) 1/4 xj 1/4 TAPCONS 6 x 6 W1.4 x W1.4 WWF OR X P.T. PLATE 20- MIN. LAP [24' MIN. LAP] #5 REINFORCING X *USP SPT22 TYP. SPACED EVENLY FIBERMESH A -j BOLTS 6" MAX FROM WEEP SCREED INSTALLED BAR X END OF 2- x PLATE 2x P.T. PLATE 1 0 d I PER MANUF. OR #4 REINFORCING BAR W P 2 6M TE ASSUMED FINISHED E A MONO OR STEMWALL--111 rT. X A )< W I> 1< W - - FOOTING MONO SHOWN GRADE 40 MIN. Fyz; 40ks! x U) 11 . wo �GRADE 1> #3 & #4 LAP SPLICE [GRADE 60 MIN. Fy= WWI X Ll j I FINISH GRADE ;0 25- MIN. LAP PO" MIN, LAP] 00 6 MIL VAPOR BARRIE I> 'AA, FOR CLARITY R 17/811 x C-4 Z (1) ROW 2x BLOCKING @ MID HGT. FOR WALL HGT. 15 8'-6". (2) ROWS 2x BLOCKING @ 3rd PTS FOR WALL HGT. > 8'-6". 1/2" GYP. WB (MIN.) @ GARAGE SIDE IF APPLICABLE. 5/8"- EXPANSION BOLT @24 " O.C. W/ 7" EMBEDMENT (MIN. SHEAR 3500#, MIN. TENSION 2600#) s 6 x 6 W1.4 x W1.4 WWF OR FIBERMESH z jo, - - - 1 (2) #5 CONT.- I- :- II- I I I I -- K .. . - 1 1 #5 LAP SPLICE jf�. NOTE: I> C14 *FOR BEARING WALL COMP. SOIL. (COMPACTED TO W/ UPLIFT ONLY F ti -7 -1 95% MODIFIED PROCTOR ASTM I ILEI I lEl I 1E, LF --­ D1557) I I 1==l I Eid I FI 41' FRAME WALL TO C.M.U. WALL CONNECTION rD TYPICAL EXTERIOR FRAME WALL FOOTING SEE TYP. WALL SECTION FOR ADDITIONAL SCALE: 3/4"=V-0" �3 SEE TYP. WALL SECTION FOR ADDITIONAL SCALE: 3/4"=V-0" SLAB INFORMATION. SLAB INFORMATION. I 6 x 6 W1.4 x W1A I WWF OR FIBERMESH GRADE igi gt ji.:3 Ir. I 1:--q- I I # 0 11 �-.# I I Him MIN. TYPICAL THICKENED SLAB EDGE L SCALE: 3/4"=V-0" � S3 BLOCK WALL BEYOND EXPANSION JOINT 1311 O.H.D. RECESS Cl) 7 -A 4. z 41 0? SEE A/S3 OR J/S6 FOR REINF. INFO. 3" MIN. CLEARANCE 1'4" (1 STC RY) V-8" (2 ST RY) GARAGE DOOR SLAB RECESS K�j SEE TYP. WALL SECTION FOR SCALE: N.T.S. ADDITIONAL INFORMATION. MM P.T. 2x 1/2" GYP. BD. HOLD GYP. BD. 1/2" FROM SLAB CONT. BEAD SEALANT INTERIOR 2X STUDS @ 24" O.C. U.N.O. 4 4 3 1/2" GARAGE CONCRETE NAILS W 1 1/2 ��-�1/2" GYPSUM WALLBOARD U.N.O. EMBEDMENT @ 12" O.C. W/ DRYWALL SCREWS @ 8"O.C. STAGGERED, FROM BOTTOM INSULATION PER CHART PLATE TO CONCRETE ON FLOOR PLAN (MIN. SHEAR 180# MIN. CONT. BEAD SEALANT C TENSION 120#) CONCRETE SLAB'--. 6 x 6 W1.4 x W1.4 -E <4 WWF OR FIBERMESH I C M ;0 E 4 6MILVAPOR EH I 7`r=­ BARRIER LIri 411 4" INTERIOR WALL SLAB STEP NON-BRG. K SCALE: 3/4"=V-0" ��S 3 E S3 2 Ills ON 3" CHAIRS 36' MIN. LAP (36- MIN. LAP] XX/xx 10. (TYP.) 8- 1141 8'. 2- -"'-#6 REINFORCING BAR #5 STD. 90 HGOK #6 LAP SPLICE TYPICAL INTERIOR BEARING REBAR DETAILS rF WALL W/ UPLIFT rG SCALE: N.T.S. SCALE: 3/4"=V-0" '\. �3 SEE PLAN 11/2" RECESS FOR RIES x 6 W1.4 x W1.4 FRAME -DOWN FALSE BEAM w/ (3) SEE ROOF PLAN S.G.D. (U.N.O.) WWF OR FIBERMESH Q.S 1 Od NAILS TO TRUSS TOP CHORD FOR TRUSS E AT 24" O.C. MAX. x CONNECTION INFO 4 SEE PLAN FOR x & LAYOUT DESIGN TOP OF BEAM SEE ROOF PLAN A A . A A ;:r)D QT0I1rTH0Al E � .. . .1 c 41 BEAM SIZE & 4 A -A ,--,2Y4 P T- CONNECTION INFO 'TE /--7/1S6." 0 B. 2x4 #2 SYP P.T. FRAMING w/ MIN 7/16" O.S.B. SHEATHING SEE A/S3/J/S6 8" L�LLUIVIN LOCATIO z ATTACHED PER NAILING FOR REINF. INFO. U) 0 SCHEDULE OPTION #1 Lu SEE TYP. WALL SECTION FOR ADDITIONAL SLAB INFORMATION. SLAB STEP & RECESS Ca) S.G.D. rM -,,,-SEE FLOOR PLAN FOR SCALE: 3/4"=V-0" � S3 S I RUC I UKAL UULUMN Zill-t & BASE CONNECTION INFO. SECURE 2x4 P.T. BTM. PLATE w/ 1/4"x3"TAPCONS AT 8" O.C. Cn 0'-0" FIN. FLR.jh I VAI :1 :1 ;lMil 11111" TRIM PER PLAN SQUARE CMU BLOCK BASE, SIZE VARIES PER PLAN w/ MIN. (2) #5 VERTICALS FILLED SOLID BRICK PAVERS or SLAB PER COMMUNITY SPECS MASONRY WALL AND PAD FOOTING 8" MASONRY WALL EXTEND FILL CELLS TO FOUNDATION PAD CONT. FOOTING STEEL MAT REINFORCING. GRADE -- -1=1 4 < ;T-P ., ­F 4 LU Mi I 4 Ir7F 1-- LU M 0- ILLJ 0 -11 E-=i I F- Uj (n Uj 4 00 0 4 M ILL 4 CUD) G F ID PAD REINFORCEMENT-] 3" MIN. CLEARANCE (SEE SCHEDULE) FOOTING WIDTH SEE SCHEDI PATIO COLUMN FTG. DETAIL � �N SCALE: N.T.S. �3 LO (D z :Z� CL z Ul) 0 Q) U-3 4--J Lu ro LU 0 CLI U*7111 E 0 Ul) LU (D C0 0) M 8 0 U- 0." CO CL CLA 0 (M LO 0 A 6 A 8 I D. N C R D C I - v or ­V vu '0 PC 5 Vw W Ui X UJI 0 N IL ss�o wl 411111WI, 0 To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code Sth Edition (2014) Residential, Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. C) 0 Z 0 0-4 4-J C) V) 13 ko > Ln rn C) (y) N M Ln in 0 N a) - U) U- Cl OC) z z E z Uj W tD U) j < Uj ED F- LU U Ln < z L0 06 z U) LW 0 0 U < In z :D 0 LL Z z LU Ln Lij < I,, L!j x: z 00 re) IID < z z co 0 Ln Z a- Ln SCALE AS NOTED DATE 2/24/2014 TECH: MJAMES VERSION NO 10 SHEET NO. S3 (MONO) I 0 (TYP) SEE ELEV. USP SPT24 @ EA. STUD CRICKET AS REQUIRED SINGLE 2x CONT. BASE (2) 2x6 OR (2) 2x8 TOP PLATE SEE PLAN (2) 2x HEADER TO SIT 2x6 2x8 WALL BEYOND FLUSH TO THE OUTSIDE SEE PLAN FOR HEADER SEE PLAN FOR SIZE CONNECTION -----2x DEAD WOOD @ MID POINT w/ (3) 12d TONEAILS SPACED DOUBLE 2x TOP EVENLY PLATE 2x BLOCKING @ EACH END W/ 1 Od @ W4 T 4"O.C. FROM EACH HEADER FACE TO BLOCKING --(2) 2x HEADER PER PLAN 2x BOTTOM PLATE W/ (1) 10d @ 8" VARIES O.C. TO EACH HEADER FACE 2 x 6 (MIN.) FRAME WALL HEADER DETAIL SCALE: N.T.S. SEE TYPICAL WALL SECTION WOOD TRUSSES @ 24" O/C UPLIFT CONNECTOR (SEE SCHEDULE) DOUBLE 2x4 SPF. #2 TOP PLATE 2x S.P.F. STUDS @ 16" O.C. SINGLE 2x CONT. TOP PLATE W/ (2) 12d INTO TRUSS ABOVE 2x CLOSURE WALL W/ STUDS @ 16" O.C. W/ (3) 10d TOENAILS T&B AS REQ'D 2x BLOCKING @ MID POINT EVERY OTHER STUD W/ (3) 1 Od NAILS PLATE W/ (2) 16d TO TRUSS BELOW 1/2" EXTERIOR GRADE SHEATHING FASTENED TO TRUSSES WITH 8d COMMON WIRE NAILS @ 4" O/C BOUNDARIES 6- O/C IN EDGES & 8" O/C FIELD USP SPT22 @ EA. STUD IL 2x P.T. PLATE 5/8" x 10" "J" BOLT @ 24" O/C MAX W/ 8" EMBEDMENT 8"X8"X16" K.O. BLOCK W/ 1 #5 CONT. AND FILLED SOLID W/GROUT 1 #5 VERT. IN CONC. FILLED CELL W/ STD. 90A HOOK IN K.O. BLOCK KNEE WALL ABOVE MASONRY WALL DETAIL MOUNTING BASE NOT SHOWN FOR CLARITY SEE DETAIL K/S4 SEAT FOR BLOCK IS POURED, IN PLACE CONCRETE GARAGE FLOOR SLAB TROWEL FINISH SEE GENERALNOTES SLOPE FORWARD FOR DRAINAGE BLOCKING (TYP.) \--ROOF TRUSS UPLIFT CONNECTOR (SEE SCHEDULE) MOISTURE BARRIER SCALE: N.T.S. SEE PLAN FOR FOOTING DIMENSIONS GARAGE ENTRY FINISHED MASONRY DETAIL SCALE: N.T.S. 1/2" MINIMUM CEMENT FINISH STANDARD 3" DIA. TEE THREADED 3" DIA. EXTENSION SCREW OFF CAP (3" DIA.) FOR CLEAN -OUT EXTERIOR FACE OF BLOCK MIN. EXTENSION FROM WALLIS 11/2" MAXIMUM EXTENSION FROM EXTERIOR FACE OF BLOCK WALL IS 2 1/4" VENT OR 2ND FLOOR TYPICAL C.M.U. WALL 3/4" FURRING STRIPS 1/2" GYPSUM BOARD W/ DRYWALL SCREWS @ 8- O.C. OR 4d DRYWALL NAILS TO DRAIN WALL CLEAN -OUT rA SCALE: N.T.S. �4 REFER TO WINDOW PRODUCT APPROVAL SHEETS FOR INSTALLATION INFORMATION BY MANUFACTURER. TYPICAL SECTION THRU WINDOW KNOCK OUT BLOCK _W/ (11 NOTCH LINTEL WHERE REQUIRED )#5 FOR CONCRETE PLACEMENT 7 0 0. - 0 4 ?IN 0 me HIM III III _0 IN IIN NOTES: FILL LINTEL AND ALL CELLS ABOVE LINTEL. NOTE: FOR BEAM DEPTH 22", PROVIDE A 4"x 4" INSPECTION PORT @ EACH VERTICAL REBAR & DIRECTLY ABOVE THE LINTEL. Q VERIFY THAT ALL REINFORCEMENT HAS BEEN PLACED PROPERLY. SEE FLOOR PLAN FOR ADDITIONAL INFORMATION. OPENINGS LESS THAN OR EQUAL TO 6-0- IN WIDTH DO NOT REQUIRE ADDITIONAL STEEL REINFORCEMENT UNLESS NOTED ON FLOOR PLAN, TYPICAL FILLED LINTEL ASSEMBLY SCALE: N.T.S. WIDTH OF OPENING VARIES 4" FORM CONCRETE INSET TO CREATE A SOLID BASE FOR 112"X9 1/2" PLYWOOD BLOCK WALL ABOVE. SCRAP MATERIAL ­ MOUNTING BASE SHOWN IN POSITION -2x6 MOUNTING BASE G S4 \ _j _j 0 FORM CREATES CONCRETE RECESS TO 2X4 (NOM.) RECEIVE GARAGE DOOR AND TO ALLOW FOR WATER SHED. KEEP STIFFENER BACK FROM SIDES ENOUGH TO ALLOW SPACE FOR FLAT MASONS TOOLS (THIS IS A RECOMENDATION FOR CONSTRUCTION OF THIS FORM. ANY MATERIAL OR CONSTRUCTION METHOD MAY BE USED PROVIDED END PRODUCT MEETS THE SHAPE AND DIMENSIONS OF THIS DRAWING.) GARAGE ENTRY FORM DETAIL 8x8x16 C.M.U. GARAGE DOOR *1111-N GARAGE DOOR ROLLER GARAGEFLOOR CONNECTION ASSEMBLY - TRAVEL DIRECTION OF GARAGE DOOR MOUNTING BASE DETAIL SCALE: N.T.S. -TRACK MOUNTING BRACKET GARAGE DOOR TRACK SCALE: N.T.S. -"'POURED CONCRETE BASE FOR 'BOTTOM OF MOUNTING B BLOCK WALL. RECESSED SPACE TO BE 2"ABOVE FINISHED FOR GARAGE DOOR AND WATER GARAGE FLOOR. SHED FORWARD THIS DRAWING. PARTIAL INTERIOR ELEVATION SCALE: N.T.S. 7 5/8" 8" 7 5/81, 8" 7 5/8" 8" INTERIOR WALL (t, E XTERIOR WALL 1 1ST COARSE 2ND COARSE 3RD COARSE MASON TO LAY BLOCK AS SHOWN ABOVE. EVERY COARSE MUST BE BONDED TO THE COARSE BELOW. EVERY THIRD (3RD) COARSE THE 11" DOOR JAMB WALL IS TO BE WOVEN INTO THE MAIN FRONT TO REAR WALL AS SHOWN. MASONRYLAYOUT D� SCALE: N.T.S. ��S4� SOLID AREAS ARE STEEL AND GROUT FULL 8x8x16 BLOCK DOOR OPENING --0t VERTICAL JAM 5/8"DIA. x 8" J-BOLTS AT 6-3/4", 41-3/4", 71", AND 96-3/8" ABOVE GARAGE FLOOR. ALL J-BOLTS WILL BE IN FILLED CELLS (2,000 PSI MIN. CONCRETE). ANCHORS MAY BE COUNTERSUNK (BUT NOT REQUIRED) BOTTOM CHORD OR 2x4 TO PROVIDE A FLUSH MOUNTING SURFACE. HORIZONTAL JAMBS DO LOC B KING W/ 2-16d TOE NAILS r(TRUSS NOT TRANSFER LOAD. EA H END C WALL 4 4 DOOR STOP 1 Uj 0 MO DING 2E < 4 �l!! 2x TOP PLATE GARAGE 2-16d NAILS @ 24" O.C. OR DOOR EQUAL TO TRUSS BOTTOM CHORD OR BLOCKING 2 x 6 P.T. 2x STUD @ 2 4 O.C. MAX. . ''1 ROVIDE P.A.F. NAILS OR 2x P.T. PLATE EQUAL @ 12" O.C. SEE A/S3 FOR I \ STAGGERED FROM BOT. DOOR TRACK—/ REINF. INFO. PLATE TO CONCRETE W/MOUNTING ANGLE NOTE: REFER TO GARAGE DOOR PRODUCT APPROVAL SHEETS FOR DOOR INSTALLATION INFORMATION PER MANUFACTURER. TYPICAL INTERIOR NOW BEARING WOOD FRAME WALL � �J TYPICAL GARAGE DOOR BUCK I/ �K SCALE: N.T.S. �4 SCALE: N.T.S. � �4 2x CRIPPLES @ 16" O.C. W/ (2) 12d TOENAILS T/B USP SPT4 w/ (6) 1 Od x 1 Y2" @ 24" O.C. 10d NAILS @ 8'— O/C TYP. DOUBLE 2x CRIPPLE STUD TYPICAL (U.N.O.) HEADER SUPPORT NO. OF JACKS & STUDS REQ. AT OPENINGS OPENING 2" x 4" WALL 2" x 6" WALL STRAPS JACKS STUDS JACKS STUDS SIZE EA END EA END EA END EA END 11-41 (2) (1) (2) (1) USP LSTA30 4'-91 (2) (3) (2) (2) (1) USP LSTA30 9'-16' (3)+ (4) (2) (�4) +(2) USP LSTA30 FLAT STRAPS PER CHART ABOVE TO BE BENT OVER TOP PLATE ** HOLD DOWN CONNECTIONS NOT REQUIRED @ BEARING WALLS NOTED WITHOUT UPLIFT SEE FLOOR PLAN NOTES FOR REQUIRED CONNECTION 2-ROWS 12d NAILS STAGGERED @ 12" O/C EACH FACE OR 3-ROWS 12d NAILS STAGGERED @ 12" O/C FOR 2"xl 0" OR GREATER HEADER (2) 2x HEADER SEE PLAN 1\ �4 \—INTERIOR HEADER (1) 2x SILL PLATE W/ (2) BOX HEADER 12d TOENAILS. ONLY EXTERIOR HEADERS (1) 2x SILL PLATE W/ (2) 12d TOENAILS. OPENING LARGER THAN 4 ft (2) 2x SILL PLATE W/ MP3 CLIPS EACH SIDE '-2X STUDS TYP. USP HTT16 TYP. U.N.O. SEE N/! HOLD DOWN CONNECTIONS NOT REQUIRED @ BEARING WALLS NOTED WITHOUT UPLI1 P.T. BOT. PLATE WALL HEADER DETAIL SCALE: N.T.S. � �4 USP SPT4 SPT24 2X STUDS @ 24" O.C. 0, ��81"X C' _ �4!0 J." M11OLT 0. AX. MIN. (2) PER BOTTOM PLATE SECTION X-2X P.T. PLATE SPT4 SEE TYPICAL WALL SECTION 12 PRE-ENGINEERED WOOD TRUSSES @ 24" O/C (TYP.) SEE ELEV. UPLIFT CONNECTOR (SEE SCHEDULE) �Y -Z(T DOUBLE 2"x4" S.P.F. TOP PLATE 7/8"STUCCO FINISH PER ASTM C. 926 APPLY 3 LAYERS W/ TOTAL THICKNESS 7/8" OVER METAL LATH. FIRST 2 LAYERS 3/8" THICK EACH. 3RD LAYER 1/8" THICK. /-CRICKET AS REQUIRED USP SPT24 @ EA. STUD 1/2" EXTERIOR GRADE SHEATHING FASTENED TO TRUSSES WITH 8d COMMON WIRE NAILS @ 4" O/C BOUNDARIES 6"O/C EDGES & 8" BLOCKING LOCKING O/C FIELD 2X4 PT STUDS @ 16- O.C. NB (2) 2X4 PT STUDS UNDER HIP CARRIER/GIRDER TRUSS USP HTA20 @ EA. STUD L MAIN SPAN MOISTURE BARRIER ROOF TRUSS UPLIFT CONNECTOR 8"X8"X16" K.O. BLOCK W/ 1 #5 CONT. —/U(SEE SCHEDULE) AND FILLED W/ GROUT 1 #5 VERT. IN CONC. FILLED CELL---- H I W/ STD. 900 HOOK IN K.O. BLOCK ALT. KNEEWALL ABOVE MASONRY WALL DETAIL SCALE: N.T.S. PIPE OR DUCT W/ PENETRATION THRU TOP PLATE W/ MORE THAN 50% OF TOP PLATE WIDTH INSTALL SIMPSON PSPN516Z W/ (12) 16d NAILS TOP SPLICE 2 ROWS 1 Od @ 3" O.C. (14 NAILS TOTAL) EA. SIDE OF %9 SPLICE STAGGERED '14, 1 Od @ 8" O/C ATTACH ALL -j EXTERIOR STUDS W/ 14116d TOENAILS TO Y60 PLATE NOTE: PLATE LENGTHS MUST BE BOTTOM SPLIC) OVERSTUD AT LEAST 4'-0" LONG. TYPICAL L11--1 TOP PLATE SPLICE DETAIL M SCALE: N.T.S. S4 F= 2240 LBS USP USP SPT4� SPT241 SP SPT4 2X TOP PLATE OVERLAPPING TRANSOM FRAMING SEE SECTION AA/Sl AND BB/Sl FOR ADDITIONAL DETAILS /-RECESS LINTEL C USP USP S PT4� SPT241 1 \-NAILED INTO TRANSOM FRAMING TRANSOM FRAMING SEE SECTION AA/Sl AND BB/Sl FOR ADDITIONAL DETAILS LINTEL 4 USP SPT22 SID //-USPT4 NAILED INTO TRANSOM FRAMING � I [USP SPT22 SPT4 USP SPT4 1 Od NAILS @ 6" STAGGERED J-BOLTS @ 24" O.C. MAX -2X P.T. PLATE 2X8 P.T. BOTTOM P TE \-5/8"x10­J" BOLT @ 24" O.C. MAX. (MIN. (2) PER BOTTOM PLATE) C --USP SPT4 1 NAI S 1' T ROOFTRUSSABOVE F 2X BLOCKING ---(2) 16d TOE NAILS EA. BLOCKING 2X8 WALL ABOVE ENTRY BLOCK W/(1) #5 CONT. & VK.O. FILLED 5/8"X10" J-BOLTS @ 2-4- O.C. MASONRY WALL @ 10d NAILS @ 6"O.C. STAGGERED 0 0 TRANSOM FRAMING N BEYOND. Kit - L PLYWOOD r PLYWOOD FASTENED TO TRUSSES 0 rE SHEATHING WITH 8d COMMON WIRE NAILS @ 4- O/C BOUNDARIES 6" O/C EDGES KE7 1 & 8" O/C FIELD SPT4 2X8 P.T. BOTTOM PLATE I 0- "J" BOLTS @ 24" O.C. MAX. (MIN. (2) PER BOTTOM PLATE) —PLYWOOD SHEATHING MASONRY WALL BELOW o-:— 5/8"X10" J-BOLTS @ 24" O.C. MAX. (MIN. (2) PER BOTTOM PLATE) ALTERNATE: 5/8"DIA. ATR EPDXIED MIN. 6" INTO BOND BEAM @ 24' O.C. FRAMING DETAILS ABOVE ENTRY K"R SCALE: N.T.S. Z co z z — z C1 V) 0 (1)Cn 4--J U_j 0)(10 0 U — 0 U-1 -a)- Of 1, E 0 21, 00 @ P, mv LU E 8 aim 04 C M cn 02, 0 r- U_ 0 2 CL 0 < M Lo 01 0 8D , C' 11-D-1 !t",4 0 t/1 iw, , - vt6,�q -,qp V10 S E 240" Z. - C-4 z aj Me, go,`... a U U-*. U M FL I . ......... z ULM J ESSIQ \N __j N r8 1111mill 00 To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code Sth Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. z C14 0 a) N :Lj C:) co� m In a) Ln U_ 0--% � fu cl� U CL OC) < z E z WLU _j C) 10 01 1 -0: 2! 6 > Ln z Ln Q 1 X 0 '0 - .2 C*.4 Ul z: I U) I'm A - P , M tW z N Ui Z LU T-4 Ln 2: < Z LU < z i� 00 ro kD co 0 Ln I z z V-4 ICL I Ln _L SCALE AS NOTED DATE 2/24/2014 TECH: MIAMES VERSION NO. 10 SHEET NO. S4 r SEE STRUCTURAL NOTES AND NAILING SCHEDULE FOR SHEATHING DETAIL TOP CHORD OR BLOCKING F FIRST FOUR ROWSOF TRUSSES @ EDGES OF 2x4 CROSS BRACE SHEATHING APPROX. 8" FROM TYPICAL@ RIDGEFASTENEDAT 48" O.C. EACHJOINTW/(3) 10d MAX. & (2)1 Od TOE NAILS @ EA. END @ 48" O.C. TOENAIL W/ (2) 16d NAILS SEE STRUCTURAL NOTES AND 7CKNAIL W/ (2) 16d NAILS TW" OUTLOOKER NAILING SCHEDULE FOR USP RT16 OR EQUAL @ @ 24" O.C. 7 SHEATHING DETAIL 2"x4" EA. OUTLOOKER OUTLOOKER @ 24" O.C. 45' 24" MAX. 41*1 TOP CORD BLOCKING 45*t 2X4 CONT'L" BRACE 71 USP RT16 OR US FOR FIRST FOUR FASTENED W/ (2) 1 Od EQUAL@ EA. Q L@ ROWS OF TRUSSES @ 11 3"@ 24" O/C. CMID OUTLOOKI OUTLOOKER EDGESOF HEIGHT 1" BRACE TO EXTEND X4 K KERN SHEATHING TYP. 2X4 KICKER 2x8 SYP#2 1" BRACE TO EXTEND @ LEAST 90% OF AT LEAST 90% OF WEB @ _O�FO/C @ 8,-011 O/C. 8 2x4 CROSS BRACE e WEB LENGTH & NOTCH @ LENGTH (SEE TABLE) APPROX. 8" FROM BOTTOM CHORD (SEE 2x6 P.T. TRUSS RIDGE FASTENED AT TABLE) SILL 1/2" CDX PLYWOOD OR EACH JOINT W/ (2) 1 Od USP RT3A WITH 8-8d 7/16" OSB SHEATHING & (2)1 Od TOE NAILS @ 91t:/ FROM LEDGER TP ATTACHED W/ 10d EA. END I BLOCKING NAILS @ 6" O.C. EDGES GYPSUM WALL BOARD GABLE TRUSS AND 12" O.C. FIELD 2"x4" PANEL BLOCKING @ 48" O.C. FOR THE FIRST 1/2" CDX PLYWOOD OR 1 OdX3" @ 3" O/C THROUGH CHORD INTO 2"x6" P.T. PLATE (4) ROWS OF TRUSSES FROM EA. END TYP. BOTTOM CORD ATTACHED W/ (2) 16-d TOENAILS 2"x4" LEDGER (MATCH BOTTOM CHORD 7/16" OSB SHEATHING ATTACHED W/ 1 Od NAILS @ 6" O.C. EDGES AND 12" O 2x4 "T" ON TOP OF PANEL BLOCKING FASTENWITH 10dx3" @4"O/C SPACED WEEPSCREED SLOPE OF ADJACENT SCISSOR TRUSS) O.C. FIELD INSTALLED PER MANUF 2"x6" P.T. SILL NOTCH 1" BRACE HERE @ 48" O.C. MOISTURE BARRIER 5/8" x 10" "J" BOLT @ 48" O.C. WEEP SCREED 5/8"x 10""J" BOLT @ 32" O.C. MINIMUM 6" FROM USP HTA20 OR EQ. @ 6-4- O.C. TYPICAL. INSTALLED PER MANUF. PLATE SPLICES W/ 3116"x2" 0 PLATE WASHER USP HTA20 EA TRUSS ALTERNATE USP LSTA18 STRAIGHT STRAP @ 4'-0" MOISTURE BARRIER @ . O/C ALIGNED WITH GABLE WEB. ATTACH TO TRUSS VERT. WEB (24" O/C MAX.) W/7-1 Odxl 1/2" AND TO MASONRY W/ (3) 3/16"x 2 1/4" NOTE: IF EMBEDDED TAPCONS. STRAP MISSED VERTICAL SECTION SECTION WEB; USE SCALE: N.T.S. MSTAM36 ON OUTSIDE SCALE: N.T.S. SEE STRUCTURAL NOTES AND NAILING IG BACKNAIL W/ (2) 16d NAILS SCHEDULE FOR SHEATHING DETAIL L 2x4 OUTLOOKER @ 24" O.C. (OPTIONAL - SEE ELEVATIONS) 7' SEE STRUCTURAL - TOP CORD BLOCkING )CKING USP RT16 OR EQUAL @ NOTES AND NAILING JR ROWS FOR FIRST FOUR ROWS 124" MAX. EA. OUTLOOKER SCHEDULEFOR OF TRUSSES @ EDGES EDGES SHEATHING DETAIL OF SHEATHING TYPICAL PICAL DOUBI. DOUBLE TOP PLATE 2"x4" CROSS BRACE &1", 2 4 Ci ROSS BRACE APPROX. APPROX. 8" FROM .0 USP 8" FROM RIDGE FASTENED AT F RIDGE FASTENED AT SPT4 @ EA. EACH JOINT W/ (2) 1 Od & (2) EACH JOINT W/ (2) STUD 1 Od TOE NAILS @ EA. END 10d & (2) 10d TOE _2X6 FRAMED WALL - SEE NAILS @ EA. END WALL SECTION FOR SPACING 2x4 PANEL BLOCKING 1/2" CDX PLYWOOD OR 7/16" @ 48" O/C FOR THE OSB SHEATHING ATTACHED FIRST (4) ROWS OF W1 10d NAILS @ 6" O.C. EDGES TRUSSES FROM EA. AND 12" O.C. FIELD END TYP. TOP & (2) 16d NAILS BOTTOM ATTACHED W/ (2) - TOENAILS 8"A 2x4 BLOCKING 2x4 PANEL BLOCKING @ 4 O.C. FOR THE FIRST (4) ROWS OF TRUSSES FROM EA. END _�2x4'7" ON TOP OF PANEL TYP. TOP & BOTTOM ATTACHED BLOCKING, FASTEN WITH W/ (2) 16-d TOENAILS 1 Odx3" @ 4" O/C — 2x4 LEDGER (MATCH BOTTOM CHORD SLOPE OF ADJACENT TRUSS) SECTION SCALE: N.T.S. REFER TO DETAIL J BACKNAIL W/ (2) 2x4 OUTLOOKER W ON SHEET S5 FOR SEE STRUCTURAL—-,,. 16d NAILS @ 24" O/C X-BRACING, AND TOP NOTES AND NAILING I TOPCORD CHORD BLOCKING SCHEDULE FOR _171 j2 BLOCKING FOR SP HGAM1 0 W/ (4) INFORMATION go ;o SHEATHING DETAIL USP RT16 OR FIRST FOUR ROWS 4"xl-3/4" WEDGE EQUAL @ EA. OF TRUSSES @ OLTS & (4) SDS 1/4" 2 ti 1 2"X4" CROSS BRACE OUTLOOKER X. M4A 24" MAX. EDGES OF 1 1/2" SCREWS f1i A -TWOODTRUSSES go 90 APPROX. 8" FROM SHEATHING TYP. RIDGE FASTENED AT 1" BRACE TO EXTEND RAT RUN BRACING EACH JOINT W/ (2) AT LEAST 90% OF WEB ,,,,--2x4 AT 24" O.C. ON TOP OF J/ 10d & (2) 10d TOE LENGTH EE TABLE) BOTT. CHORD FOR 4 TRUSS SPANS NAILS @ EA. END AL TRUSS ATTACHEDW/2-16d 2X4 PANEL BLOCKING or-112" CDX PLYWOOD OR 7/16" AT EA. TRUSS JOINT (2) 2" x 4" LAM I NATIONS W/ (1) ROW (3) 2" x 4" LAMINATIONS W/ (1) ROW (3) 2" x 6" LAMINATIONS W/ (2) ROWS OF @ 48" O/C FOR THE FIRST (4) ROWS OF (2)16d NAILS OSB SHEATHING ATTACHED W/ 1 Od NAILS @ 6- O.C. 2X4 BLOCKING @ 24" OF STAGGERED 10d COMMON WIRE NAILS OF STAGGERED 30d COMMON WIRE NAILS STAGGERED 30d COMMON WIRE NAILS TRUSSES FROM EA. E - ES AND 12" O.C. FIELD O/C W/ 2 - 16d (D = 0.148', L = 3-) OR EQUAL (D = 0.207", L 4 1/2") OR EQUAL (D = 0.207", L = 4 1/2") OR EQUAL END TYP, TOP & - -------- /-JACK TRUSS TOENAILS @ EA. END NOTES: BOTTOM ATTACHED SEE PLAN FOR 1) ADJACENT NAILS ARE DRIVEN FROM OPPOSITE SIDES 4) FOR 4-PLY, PROVIDE 1/4" DIA. x 5 1/2" LAG SCREWS OR EQUAL W/ (2) 16-d TOENAILS XONNECTION MASONRY WALL OF THE COLUMN (SPACE AS SHOWN FOR 3-PLY) ARCHITECTURAL FINISH 2) ALL NAILS PENETRATE AT LEAST 3/4 OF THE THICKNESS 5) FOR 5-PLY, PROVIDE 1/4" DIA. x 7" LAG SCREWS OR EQUAL 2X47" ON TOP OF PANEL-/ L OF THE LAST LAMINATION (SPACE AS SHOWN FOR 3-PLY) BLOCKING, FASTEN WITH 2X4 BLOCKING W/ 1 Odx3" @ 4" O/C (2) 12d TOENAILS 3) EACH 30d COMMON NAIL MAY BE REPLACED W/ (2) 16d 6) REFER TO NDS SECTION 15.3 FOR ADDITIONAL INFORMATION EXT. WALL CONN. B.U.C., SAME NUMBER OF ROWS, SAME SPACING) NON - LOAD BEARIN LOCATION rD COMMON NAILS. (ONE INTO EACH OUTSIDE FACE OF SEE TYP. WALL SECTION FOR SCALE: 3/4" V-0" TYPICAL NAILING SCHEDULES FOR BUILT-UP COLUMNS r8 ���5 ADDITIONAL INFORMATION. SCALE: N.T.S. '\.._S5_,) 1INIMUM 2x 'ROSS BRACING 3EE PLAN FOR OCATIONS) (2) 16d PER JOINT L- CONTINUOUS BOTTOM CORD BRACING 2"X4" MIN. SEE M/S5 CROSS BRACING DETAIL SCALE: N.T.S. � S5 12 6.9 MAX. ---- S5 GABLE END BRACING DETAIL 2"X4" OUTLOOKER @ 24" O.C. W/ (2) 1 Od PER JOINT ILI 10dXY O/C TOENA 6" O/C 6d W/ (2) 1 TYPICAL NAILS ALTERNATE NON -DROP GABLE END DETAIL SCALE: N.T.S. GABLE TRUSS 1" BRACE W/ 1 Od @ 4" O.C. ---Z(SEE SCHEDULE FOR SIZE AND LOCATION) S5 CONT. BEARING MEAN WALL HEIGHT UP TO 30*-0" - SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION "Al _IZ- SCALE: N.T.S. 8d @ 6"O/C WOOD TRUSSES USP HGAM10 W/(4)-3/16"x1-3/4" - WEDGE BOLTS & (4) SDS 1/4" x 1 1/2" SCREWS -BACKNAIL W/ (2) 2x4 OUTLOOKER 16d NAILS @ 24' O/C TOP CORD BLOCKING FOR USP RT1 Ii 6R FIRST FOUR ROWS EDGES OF EQUAL @ EA. OF TRUSSES @ OUTLOOKER MAX. SHEATHING TYP. 0 EXTEND AT LEAST 90% OF WEB LENGTH (SEE TABLE) ABLE TRUSS 1/2" CDX PLYWOOD OR 7/16" OSB SHEATHING ATTACHED W/ 10d NAILS @ 6" O.C. EDGES AND 12" I O.C. FIELD --(2) 16d NAILS _Q 2x4 "T" ON TOP OF PANEL i i i I I W X. 2 M7A BLOCKING, FASTEN WITH 1 Odx3" @ 4" O/C USP HGA10 @ 36" O.C. DBL. TOP STUD WALL PLATE (SEE TYP SEC ) 2X4 BLOCKING-,,,,,,, --2x4 "T" BLOCKING @ 48" O.C. 16d NAIL 1" BRACE ATTACHED W/ 1 Od NAILS @ 4" O.C. TYPICAL GABLE TRUSS WE DOUBLE 1" BRACING DETAIL SCALE: N.T.S. 2x4'T'BLOCKING 2x4 BLOCKING @ 48" O.C. "L" BRACE ATTACHED - 16d NAIL W/ 1 Od NAILS @ 4" 0. TYPICAL W :4� GABLE TRUSS WEB SINGLE 1" BRACING DETAILt/_6 � S5 SCALE: N.T.S. DIAPHRAGM BLOCKING @ 48" O/C �-7 GABLE TRUSS TRUSS VERTICAL . . (2) 2"x8" 1" BRACE USP SPT24 @ EACH STUD FASTENED WITH (3 16d PER SIDE SECTION 4 SCISSOR GABLE 1171 BRACE r7 SCALE: N.T.S. AS PER HIB 91 SCALE: N.T.S. �, �5 2 x 4 BLOCKING W/(2) 1 Od TOE NAILS @ EACH END @ 24" O/C (TYP) \-BRACING W/(3) 10dx3"@ NEACH CONN. @ 24" O/C -MOISTURE BARRIER \_BONDBEAM MASONRY WALL RCHITECTURAL FINISH �A EXT. WALL CONN. NON - LOAD BEARING LOCATIO (UNEVEN CLG.) rE — SEE TYP. WALL SECTION FOR SCALE: N.T.S. k\_ S5 ADDITIONAL INFORMATION. 1" BRACING REQUIREMENTS STUD SPACING NO 1" BRACE (1) 2"X4" (U.N.O.) 1" BRACE 2"x6" (U.N.O.) 1" BRACE 240' 01011- 3-4- T-0" - 6'-0" 6'-0" & GREATER SCISSOR GABLE - (1) 2"W' #2 S.P.F. @ EACH VERTICAL AND (2) 2"x8" FULL HEIGHT @ DIAPHRAGM BLOCKING NOTE: 1) 1" BRACE MUST EXTEND AT LEAST 90% OF WEB LENGTH EXCEPT, SCISSOR GABLE WHICH REQUIRES BRACE TO EXTEND FULL HEIGHT OF GABLE. 2) 1" BRACE TO BE FASTENED TO GABLE STUD WITH 10dx3" NAILS @ 4" O/C. 3) SEE 6/S5 FOR MORE INFO. PRE-ENGINEERED WOOD TRUSSES OVERLAP TRUSS BRACING AT LEAST TWO TRUSS SPACES SECTION r9 SCALE: N.T.S. � �5 '--MINIMUM (2) 16d PER JOINT \-MINIMUM 2X4 TRUSS BRACING TRUSS BRACING OVERLAP DETAIL SCALE: N.T.S. 6" OVERLAP M S5 1- BRACE W/ 10d @ 4- O/C (SEE SCHEDULE FOR SIZE AND LOCATION) @ EACH STUD GABLE END BRACING DETAIL SCALE:34"=V-0" MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION ENDJACK 1 V-0" MAX. Cr LU 0 Cr CORNERJACK 0 z oc 0 0 HIP FRAMING REFERENCE PLAN z W 20'-0" MAX 20'-0" MAX W' BRACE SEE DET. J/S5 CONTINUOUS BOTTO� CHORD BRACING 2X4 MIN. 11111 P 1�11 I NOTE: 1) SEE TRUSS MANUFACTURER'S TRUSS ENGINEERING CUT SHEETS FOR ADDITIONAL PERMANENT BRACING THAT MY BE REQUIRED 2)"T" BRACING MAY BE USED IN PLACE OF PERMANENT BRACING PROVIDED IT EXTENDS OVER AT LEAST 90% OF THE WEB. EQUIRED MINIMUM PERMANENT TRUSS BRACING PLAN R AS PER BCSI 1-03 SCISSOR TRUSS SCISSOR TRUSS W/ DROP CEILING BRACING DETAIL CL ITOP & BOTTOM CHORD GABLE END BRACING @ 4'-0" O.C. MAX. FOR FIRST (4) ROWS OF TRUSSES SCALE: N.T.S. 2X4 BRACING @ 48" O.C. CONTINUOUS TO FIXED LOCATION ATTACHED W/ 2-10d @ EA. TRUSS (NOTE: BRACING MAY BE PLACED ON EITHER TOP OR BOTTOM OF THE BOTTOM CORD) COSMETIC DROP CEILING FRAMING MEAN ROOF HEIGHT UP TO 30'-0" SCALE: NTS SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION WOOD FRAMED GABLE END BRACING DETAIL MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES SCALE: N.T.S. FOR WIND SPEED SPECIFICATION 0 LO z C1 0 z 0 z < z Cz V) (D Q) — C/3 4--J Uj ro U LU 0 E Ln 0 2 V) .20 CN 0 co U-1 n cl) M ce) �m -0 v) 0, r_ N .2 CD C) U. 00 co CL < 0 0 LO 6 8 D N C 11, 11 C A . W > wtk 9 -4it, f*, d -KI a- 1. W (n 0) si 4 LL 10 N 9/, imnwllk� El To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained Ithin these drawings comply with the Florida Building Code 5th Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. C) Z r-4 0 cu r-, C) V) M ic:� M p Ln M Ln z "2�� U1 U_ 0--� - zrn lcl� U M _4 0-00 z E 3i LU F- WC:) _j 0 z g 480, ffli 0 8 �j z M�Q l-M RZ Ln I:z < 2: C: Ln UJI E x 0 r.-4 U o z _j < cc 117-4 rl.% ILL <0 � at Z uj j�-. z LLJ In 1-2 ­4 1 < z 00 Lr) z Z 100 0 _-n rn T-1 0- V) SCALE AS NOTED DATE 2/24/2014 TECH: MJAMES VERSION No' 10 SHEET NO. S5 (1) LAYER TYPE 11 (#30) UNDERLAYMENT FOR ROOF PITCH >412 (2) LAYERS TYPE I OR TYPE 11 (#15 OR #30) UNDERLAYMENT FOR ROOF PITCH 4:12 OR LESS. 12 PRE ENGINEERED WOOD TRUSS @ 24" HURRICANE ANCHOR @ EACH TRUSS O.C. MAX. —SHINGLE ROOF FOR UNDERLAYMENT SHINGLE ROOF REQUIREMENTS SEE R905. INSULATION— 15/32" CDX PLYWOOD OR 7/16" BAFFLE O.S.B. (SEE ROOF NAILING INSULATION P SCHEDULE ON SHT SNII) CHART ON FLOO PLAN ALUMINUM DRIP EDGE ALUMINUM FASCIA 5/8" OR 1/2" HIGH STREN GTH CEILING 2x SUB FASCIA BOARD PER CODE W/ 13/8" DRYWALL NAILS OR DRYWALL SCREWS 7" O/C SEE SOFFIT SHEET CEILING & 8" O/C WALLS ATTACHED WALL SHEATHING TO 1/2" GYP WB (2) TOP PLATE W/ 8d @ 4" O.C., 2 ROWS DOUBLE 2X S.P.F. TOP PLATE 1X2 NAILER PLYWOOD SHEATHING 2X BLOCKING @ EA. WALL 5j NAILED PER NAILING SCHEDULE SEE DETAIL C/S6 SHEATHING JOINT U) FOR MORE INFO 16" O.C. 2X S.P.F. STUDS 0 UJ 0 W1 (4) 16d TOENAILS TO TOP PLATE 0 7/8" CEMENTITIOUS FINISH PER ASTM C. 926 APPLY 3 LAYERS W/ TOTAL THICKNESS 7/8" OVER 2X BOT. PLATE W/ (2) 10d @ 6" O.C. _j METAL LATH. FIRST 2 LAYERS 3/8" THICK EACH. 3RID 3/4" PLYWOOD DECKING GLUED AND NAILED W1 1 Od _j =) t@ LAYER 1/8" THICK. COMMON @ 6" O/C EDGES AND 12- O.C. FIELD U_ INSULATION PER 1/2" GYP. WEI OR 3/8" PLYWOOD/ TYPE 2-M-W OSB CHART ON FLOOR PLAN (DRAFTSTOPPING) TO BE NAILED W/8d COMMON @ 6" O/C TOONE SIDE OF THE FLOOR TRUSS FORAN AREA 1000SQ. B R < FT. OF FLOOR AREA & SEALED PENATRATION AREA W/ FOAM. DRAFTSTOPPING SHALL DIVIDE THE CONCEA� S6 S6 SPACE INTO APPROX. EQUAL AREAS. FLOOR SYSTEM ETAL SEAT ER PLAN 0 R FELT < PAPER FOR MOISTURE BARRIER 1/2" HIGH STRENGTH OR 5/8" GYP WB (OR 5/8" GYP. TYPE " X- @ GARAGE ONLY) W/ 13/8" DRYWALL NAILS OR DRYWALL SCREWS 7" O/C CEILING & 8'O/C WALLS STD. 90 HOOK (SEE DETAIL) 1/2" GYP WB 8"x8"X16" CONC. KNOCKOUT INSTALLATION PER BLK. W/1#5 ROD CONT. FILLED CHART ON FLOOR PLAN SOLID W/GROUT NOTE: LAP SHEATHING TO BOTTOM OF BAND JOIST TYPICAL ,,,,�ARCHITECTURAL FINISH (1) #5 VERT. IN FILL CELLS (SEE FOUNDATION PLAN & NOTES) co I.Ij 4"x4" INSPECTION PORT AT cr_ a. EACH FILL CELL TYPICAL 1x WD FURRING @ 24"O.C. LU a. CO AT GARAGE CONTRACTOR BASEBOARD TO CUT BLOCK OR POUR MIN. 2500 PSI CONIC. SLAB CURB DUE TO SLOPE MIN. PSI MAY VARY PER NOTE: EXTEND DECO FINISH MUNICIPALITY 410 6" BELOW GRADE 04 FINISH GRADE ;0 cl) A 4 A 6x6 W1.4xW1.4 WWF OR FIBERMES Val STD. 90 *HOOK (3) # 5 REBAR ON 3" CHAIR 4 (SEE DETAIL) W/3" MIN. CLEARANCE ,TYP 2-STORY WALL SECTION �j SCALE: 3/4"=1'-0" S6 USP LSTA24 STRAP W/ 8-1 Old x 11/2" NAILS TO STUD 2nd FLO BEAM/GI 2ND FLOOR FRAME CONNECTION SEE J/S-6 FOR ADDITIONAL INFORMATION. SCALE: N.T.S. USP LSTA24 STRAP W/ 8-1 Old x 1-1 /2" NAILS TO STUD & 8-1 Od x 1-1/2" TO BAND JOIST @ EA. STUD 2nd FLOOR WALL----- BAND JOIST 'USP MP4F @ 24" ox. w/ 12-8d NAILS 1 st FLOOR WALL USP LSTA24 STRAP w/ 8-1 Old x 1 1/2" NAILS TO STUD & 8-10d x 1 1/2" TO BAND JOIST @ EA. STUD 2ND FLOOR FRAME CONNECTION @ WOOD 1ST FLR. SCALE: N.T.S. UPLIFT CAP = 928 PLF SHEAR CAP = 355 PLF SEE J/S6 FOR ADDITIONAL INFORMATION. 2"x4" PANEL BLOCKING @ 48" O/C FOR THE FIRST V-101" OF END WALL FROM EA. END. (TYP.) TOP & 'END SHEATHING TO )F BEAM OR GIRDER XE W/ I O.C. )OR TRUSS/JOIST 2"x BOT. PLATE W/ (2) 10d @ 6" O.C. NOTES: * USE MP4F & EXTEND SHEATHING TO BOTTOM OF RIM BOARD/BAND JOIST FOR SHEAR WALL ONLY. SPACER BLOCKS E S6 117 CORNER TYPICAL "T" AND CORNER DETAILS rN SCALE: N.T.S. � �6 BOTTOM CHORD ATTACHED W/ (2) 2ND FLOOR FRAMING - SEE 16d TOE NAILS SECTION J/S6 DECKING ATTACHED WALL SHEATHING BOTTOM PLATE/CHORD W/ 8d 1TO @ 4" 012 ROWS STAGGERED FLOOR TRUSS SEE FRAMING PLAN FLOOR TRUSS SEE FRAMING WEEPSCREED PLAN INSTALLED PER MANUF. 2"1 CROSS BRACE @ 48" USP HTA20 @ 24" O.C. W/ O/C FOR THE 1 ST 2'-0" OF 10-1 Od X 1 1/2" NAILS INTO END WALL W/ (2)1 Odx3" @ EA. BLOCKING TRUSS & MIN. 4" END INTO 2"1 BLOCKING EMBEDMENT IN CONC. 2ND FLOOR FRAME CONNECTION R PARALLEL TO MASONRY WALL SCALE: 3/4"=1'-0" SEE TYP. 2-STORY WALL SECTION FOR ADDITIONAL INFORMATION. 'ex -)I U U,) p I 2"x BOT. PLATI (2) 10d @ 6" 0.( PRE-ENGINEE FLOOR TRUSIc ATTACHED WALL SHEATHING CONTINUOUS TO BOTTOM RIBBON W1 8d @ 4" O.C., 2 ROWS STAGGERED 2X4 RIBBONS, EACH W/ 4-16d NAILS INTO EA. FLOOR TRUSS WEEP SCREED INSTALLED PER. MANUF. USP HTA20 @ EA. TRUSS W/ 10 - 1 Old x 1 1/2" NAILS INTO FLOOR TRUSS & MIN. 4"EMBEDMENT IN KO BLOCK FLOOR CONNECTION ( B @ MASONRY 1ST FLR. SEE J/S6 SCALE: 3/4"=V-0" S6 FOR ADDITIONAL INFORMATION. PROVIDE CONTINUOUS BLOCKING FROM B.U.C. TO MASONRY BELOW (4) 1/4" X 2 1/4" TITEN SCREWS TO MANSONRY WALL PER STRAP WOOD TO MASONRY CONNECTION W/ MSTAM36 SEE J/S6 FOR ADDITIONAL INFORMATION, ,-- B.U.C. 8 - 1 Od NAILS TO STUD PER STRAP MASONRY WALL SCALE: N.T.S. RIBBONS DETAIL (FLOOR TRUSS.) i(�O � SCALE: 1 1/2"=V-1)" "6,) NOTE: 1�1 ",/— SEE SHEATHING SEE TYPICAL WALL SECTION SPECS ON FLOOR C/S3 FOR ADDITIONAL INFORMATION ,�-1/2" GYP. W.B. MIN. @ GARAGE SIDE IF APPLICABLE (1) ROW OF 2x BLOCKING @ MID — I HGT. FOR WALL HGT. < V-15". (2) 5/8"DIA x 10" "J" BOLT W/ 8" ROWS OF 2x BLOCKIWG_ @ 3rd PTS EMBED-MENT @ 24" O.C. W/ FOR WALL HGT. > V-13" 2"DIA.X 3/16" PLATE WASHER USP SPT22 @ EA. STUD F(MIN. SHEAR 3500#. MIN. TYPICAL 2 x STUDS @ 16" O.C. TENSION 2600#.) 2X P.T. PLATE 6 x 6 W1.4 x W1.4 FWWF OR FIBERMESH ;r -A. 4�. ,'A FI I � � �;;I I I I I . (3) #5 CONT. ON T 8 V-8" 8" CHAIR W/ 3" MIN. CLEARANCE INTERIOR 2-STORY FRAME SECTION rs SEE TYP. 2-STORY WALL SECTION FOR SCALE: 3/4"=1'-0" ADDITIONAL SLAB INFORMATION. S6 15/32- OSB EXPOSURE1 SHEATHING PROVIDE BLOCKING AS REQUIRED PER SECTION X_X IF NOT FULL HEIGHT SHEET (2)- 2x TOP PLATE BEYOND I =-15/32"OSB EXPOSUREI SHEATHING Lu Lu SOLID 2x V) C BLOCKING @ ALL SHEATHING EDGES(SEE OPENING SECTION X-X) Lu 0. 2xSTUDS w BEYOND. W SEE PLAN V)� FLOOR SYST M 11 -1 -JU 77 \-2x'4 P.T. BASE 2x RIBBON OR VERTICAL PLATE BEYOND BLOCKING SEE PLAN BETWEEN FLOOR WALL SHEATHING SYSTEM WALL ELEVATION DIAGRAM 4 FT. 4 FT. 2 2 5 FT. 4 FT. 5 FT. 4 FT. 2 FT. 4 FT. 4 FT. \ ROOF NAILING ZONE DIAGRAM ROOF NAILING SCHEDULE: NAILING ZONES (SHINGLEAN TILE D� ZONE 1: 8d RING SHANK NAILS 6"O.C. ON EDGE AND 6" OC IN FIELD ZONE 2: 8d RING SHANK NAILS 6" O-C. ON EDGE AND 6" OC IN FIELD z ZONE 3 8d RING SHANK NAILS 4" O.C. ON EDGE AND 4" OC IN FIELD 0 z (NOTE: IF 5/8"PLYWCOD IS USED, CONTRACTOR MUST USE 10d RING J. 0 SHANK NAILS) NOTE: ROOF SHEATHING: (APA RATED EXPOSURE 1) 1/2"PLYWOOD a u i Lu (TILE) OR 711V OSS MIN, (SHINGLES) SPAN RATED 24/16 81 SHEATHING MAY BE INSTALLED VERTICALLY OR HORIZONTALLY, ATTACH co PER NAILING SCHEDULE. PANEL EDGES WILL NEED TO BE ATTACHED TO U. cr STUD AND OR BLOCKING AT ALL EDGES. C11 uj 0 A MINIMUM I/8"SPACE IS RECOMMENDED BETWEEN PANELS AT EDGES AND END JOINTS ALLOW FOR EXPANSIONS FASTENERS SHALL NOT PENETRATE SURFACE MORE THAN 1/8" 318" "S"= NAIL 3/8' SPACING 41t"3144" S 1/2' S 1/2" S 112- 4S, SINGLE NAIL EDGE SPACING DOUBLE NAIL EDGE SPACING NAIL AT BASE 2 ROWS @ 4- O.C. W/8d COMMON NAIL NAIL AT TOP PLATE TWO ROWS @ 4" D.C. W/8d COMMON NAIL @ NAIL OPENING PERIMETER @ W O.C. W18d COMMON NAIL @ NAIL INT. AT T' O.C. W/8d COMMON NAIL STAGGER ALL VERT. JOINTS & NAIL @ 4" O.C. W/8d COMMON NAIL SHEATHING SPLICES @ HEADER - NAIL SHEATHING TO HEADER W1 8d COMMON NAILS @ 4" D.C. @ (2) 8d NAILS @ Y O.C. TO EACH TRUSS END OR a VERTICAL MEMBER IF GABLE END [NOTE: 8d NAILS FOR WALL SHEATHING MUST BE MIN. 131* X 2 1/2" DO NOT OVERDRIVE NAILS, FASTENERS SHALL NOT PENETRATE SURFACE MORE THAN 118". AT ALL PANEL BLOCKING LOCATIONS MIN 2 X 4 #2 SPF TURNED VERTICAL W/ 7/16- OSB FLITCH PLATE TO W/ (2) 12d TOENAILS EA. END, NAIL FLITCH PLATE To VERTICAL W1 (4) 8d NAILS ", — "'o v , "" WALL SHEATHING INSTALL. STAGGERED &NAILING SCHED. SECTION X-X r 2-ROWS 12d NAILS STAGGERED @ 12" O/C EACH FACE OR 3-ROWS; 12d NAILS STAGGERED@ 12" O/C FOR 2x CRIPPLES @ 2"x10" OR GREATER HEADER 16" O.C. W/ (2) 12d TOENAILS T/B SEE FLOOR PLAN NOTES FOR REQUIRED CONNECTION (2) 2x HEADER SEE PLAN "--INTERIOR HEADER 10d NAILS @ 8" O/C TYP. BOX HEADER (1) 2x SILL PLATE W/ (2) ONLY 12d TOENAILS. DOUBLE 2x EXTERIOR HEADERS CRIPPLE STUD (1) 2x SILL PLATE W/ (2) TYPICAL (U.N.O.) 12d TOENAILS. OPENING LARGER THAN 4 ft (2) 2x SILL PLATE W/ MP3 CLIPS Nt EACH SIDE 'IA' 0 SEE PLAN FOR REQUIRED CONNECTIONS LOAD BEAR I NG/EXTERIOR FRAME WALL HEADER DETAIL 2x STUDS TYP. P.T. BOT. PLATE FLOOR TRUSS / (2) ROWS OF 2x BLOCKING @ THIRD POINTS 5/8"DIA. x 10" "J" BOLT W/ 8" EMBEDMENT @ 24- O.C. W/ 2"DIA.X 3/16" PLATE WASHE7R (MIN. SHEAR 3500#. MIN. TYPICA\L TENSION 2600#.) 2500 PSI CONCRETE MIN. SLAB W/6x6 W1.4xW1-4 WWF OR FIBERMESH 4. E 4 4 7 I= — 1 _'[="T 4 Cl) =I I MI I I—= 4-. 7 11 r=__ t 11 E. M S6 HEADER SUPPORT NO. OF JACKS & STUDS REQ. AT OPENINGS OPENING 2" x 4"WALL 2" x 6" WALL STRAPS JACKS STUDS JACKS STUDS SIZE EA END EA END EA END EA END 1-4 (1) (2) (1) (2) (1) USP LSTA30 4`4 (2) (3) (2) (2) (1) USP LSTA30 9'-16' (3) (3) (2) (3) 1 (2) USP LSTA30 PLYWOOD SHEATHING NAILED PER NAILING SCHEDULE SEE DETAIL C/S6 FOR MORE INFO -2X STUDS @ 16" O/C 7/8" STUCCO FINISH PER ASTM C. 926 APPLY 3 LAYERS W/ TOTAL THICKNESS 7/8" OVER METAL LATH. FIRST 2 LAYERS 3/8" THICK EACH. 3RD LAYER 1/8" THICK. I USP SPT22 @ EA. STUD -2X P.T. PLATE WEEP SCREED INSTALLED PER. MANUF. 00 FINISH GRADE (3)#5REBARON3"CHAIR--/j 4" 1 """' 1 1-81' W/3" MIN. CLEARANCE ALTERNATE FOOTING v @ WOOD 1ST FLR. SEE J/S6 SCALE: 3/4"=1'-0" � �S6 FOR ADDITIONAL INFORMATION. Z zom z CIL Cz Z C—Z) 4-J LU 0 Lli E 0 2 cl) C) .20 Ca E RIM _= m -a m - 'r- C`4 0 2 � C) 0 4) = LL 5 -2 0 M (n Jle CL CL, 4) < ur) &:s < 6 A 8D. I x C." 1) C _\\N W t, F Ci 5" 0 "::U, N LLI 1. 1 LU �U, < 0'..'s 0 a a LL C" 1 W1 " 41 'I'll 11111111,00 0 To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code Sth Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. 0 0 z r-4 0a) N ii-I :Lj C:) L0 =) tD 0 rn 0 CD M U-) (0 Ln < L LL CL � (y) M _4 ca. CO z z E z Uj C;l, _j C:) W ko cx� 0 > 22 Ln U) __j z Ln F- r-4 LU M 0 o 0 U. agg CII < Cr 08 98� ILL z< cz a Lu Z z LIJ Ln T-1 . Lij M < UJI z -z LLI 00 ko LI Z z tu— Uj 0 z 0 rn r�, T__4 5 a- :r uj x SCALE AS NOTED DATE 2/24/2014 TECH: MJAMES VERSION No' 2nO SHEEr NO. S6 ALL STAIR STRINGERS AND TREADS TO BE #2 SYP (MIN.) THREADS, RISERS, AND 3/4" PLYWOOD NOT SHOWN IN DETAIL FOR CLARITY ALL WOOD TO WOOD CONNECTIONS TO BE GLUED (PL 200) AND NAILED (MIN. (2)16d). 13/4xll VL 2x4 UNDER STRINGER - GLUED AND NAILED TO LANDING 2X4 UNDER STRINGER GLUED AN NAI LED TO LAN DI NG BLOCKI NG — D 2X4 PT NOTCH-4 I I I I INTO STRINGER I D -,-2x8 BLOCKING FOR STRAP L-1x4 blocking 20" FLAT STRAP NAILED TO RISER AND THEN WRAPPED AROUND STUD (USP MTW12) PLAN VIEW SCAL-E-T" l'-O;' THESE DETAILS ARE NOT PLAN SPECIFIC. THEY ARE PROVIDED TO YOU AS A STANDARD TO CONSTRUCT STAIRS. REFER TO PLAN DETAILS C:n[:) DICE= AKIM DI IKI IKII=nDRAATInKI 2X4 SPF NOSING GLUED AND NAILED MATCH NOSING ON OTHER TREADS JOIST REHIM7% SYP 2X8 SYP 2x8 SYP STRINGER MUST M/ CONTACT WITH LAN 2x4 CUT C.. DOES NOT BEAR IN WALL GLUED TO 2x8 4(t.) SE STRINGER MUST MAKE FULL CONTACT WITH LANDING 41 1V PT NOTCHED INTO STRINGER - D NAILED TO FLOOR WITH GLUE STRINGER CONTACT POINTS CTION VIEW "All SCALE: 1 V-1)" 2X4 PT NOTCHED Ih AND NAILED TO FL( 2X4 CUT ON BEVEL AT STRINGER CON' DOES NOT BEAR IN WALL SECTION VIEW "D11 SCALE: 1 V-0" FILLER STRIPS ADDED PLYWOOD GLUED & SCREWED TO PLYWOOD DECKING -2x SYP CUT TO FIT BEARS IN WALL -------2xl2 SYP BEARS IN WALL BULLNOSE DETAIL SCALE: 1 V-0" -2x4 GLUED AND NAILED SECTION D-D SCALE: 1 V-0" 2x12 SYP ALIGN THIS STUD WITH STRINGER FACE OF 2ND RISER 314" RISER CUT TO FIT MAINTAIN BETWEEN J" AND �'GAP TOP AND BOTTOM, GLUED AND NAILED TO STRINGER 2x4 BEHIND RISER BLOCKING FOR ,,�—`Ix4 GLUED AND NAILED TO STRINGER STRAP GLUED TO RAFT RISER AND TREAD STOP 2x8 SYP DRYWALL STOP MUST NOT TOUCH STRINGERS BLOCKING FOR 2x12 PT UNDER 2x12 C 2x4 SYP BLOCKING FOR STRAP (USP MTW12) BEHIND RISER ATTACH ALL COMPONENTS OF STAIR TO CONC. W/ J" x 2 TAPCONS @ MAX. 32" O.C. SECTION VIEW 111311 SCALE: 1 V-1)" R SECTION VIEW "Ell SCALE: 1 V-0" GLUED AND NAILED TO STRINGER DRAFT P SYP DRYWALL STOP ST NOT TOUCH IINGERS G 4 BLOCKING FOR 2x12 4 PT UNDER 2x12 TOP OF STRINGER SCAB 2x4 GLUED AND NAILED (EACH SIDE) TO BOTTOM EDGE OF 2x12 STRINGER --L---PROVIDE MOISTURE PROTECTION ATTACH ALL COMPONENTS OF STAIR TO CONC. W/ 4" x 2 J" TAPCONS @ MAX. 32" O.C. ) C _1x4 GLUED AND NAILED TO STRINGER VIC11 SECTION VIEW SCALE: 1 V-10" CONN. TO BOTT OF NEWEL POS7 PER CONTRACT PROVIDE SOLID BLOCKING LFLOORGIRDER BELOW ALL NEWEL POST 2X4 CUT ON OR 1 x 16" VL BEVEL GLUED�� FROM JOIST TO JOIST. USE AND NAILED TO 2 X 12 BLOCKS, GLUED AND NAILED TO JOIST. LVL NEWEL POST it if BLOCKING SECTION VIEW G SCALE: 1 1 1-01, SCALE: JOINT -TO )ISTS) NAILED AND TOP PLATE NTO RIM BAND, ID NAILED TO WALL BELOW JOINT -TO )ISTS) !L POST LET INTO �LOCK IDE KING 2X8 BLOCKING FOR NEWEL POST TO ANCHOR TO. (GLUED AND NAILED) FLOOR TRUSSES JTJ L — El M i I NIIJF WA FA =101011 9 OMEN MEMO, 2X4 PT NOTCHED INTO STRINGER AND TAPCONED INTO FLOOR WITH GLUE -AT STRINGER CONTACT POINTS \/-2x8 SYP DRYWALL STOP MUST NOT TOUCH STRINGERS 2X4 BLOCK IN KNEEWALL FOR 2x12 NAILING X4 GLUED AND NAILED TO STRINGER FOR DRYWALL SPACING yAH� SECTION VIEW SCALE: 2X4 PT NOTCHED INTO STRINGER AND TAPCONED INTO FLOOR WITH GLUE -AT STRINGER CONTACT POINTS 0 .1 17L2x8 SYP DRYWALL STOP MUST NOT TOUCH STRINGERS xffGLUED AND NAILED TO STRINGER -.#rOR DRYWALL SPACING SECTION VIEW 6TAIR C;UN%51 RUG I IUN UE I AlLb SCALE: 1,-0,; (IF 11 X1 7 REDUCE SCALE.5) SCALE: AS NOTED 0�10 z Z z < I 0- z Cz V) 0 4--J u-I C) 0 LU L/) O� Ln E 0 flu U LU — E 8 0) c"I (M ce) C '0 0 M_ clj 0 q g :S U_ 2 :3 1 o W < 0 LO 8D. N 0, 1 1) C *I \\%J111111IN xx �- lox NX 0 7"It tf4z S ex . :3 Q. 0 CQ_ uf-4.n Uj R a a9 6 4, M tN r 2 4' 1� F 10 C11 ........ ve'm *9, ESS\ To the best of the Engineer's knowledge, Information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code Sth Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. Z t-4 0 (v F-I 4.J C) V) — %D V) M C:) C, M r.- 4-J Ln M Ln -0 CL V) - V' z r- ON U_ ty- U a 00 z < z E LU W 110 u g F� Ag� .4 U 08 I,- ui 20 2: Ln co z Ln 0 r4%j Uj 0 U o z �25�� LU Ln X: 00 < z z 0 In Uj 0 M z SCALE AS NOTED DATE 2/24/2014 TECH: MJAMES VERSION NO. 10 SHEET NO. ST Z ? DOOR JAMB (REFC:D r--11X44 r-1/2" DRYWALL DOOR JAMB (REFER 11 X 4 11112" DRYWALL DOOR JAMB (REFER 1 X 4 Fl/2" DRYWALL MAX. 8" UNACCEPTABLE INSTALLTION TO SHT. SDW2-Kl"'l P.T. TO SHT. SDW2-Kl TO SHT. SDW2-Kl FOR CONN. DETAILS PROPER INSTALLATION DO NOT DO THIS 2"x BOT. PLATE W/ (2) 1 Od @ 6" O.C. FOR CONN. DETAILS,)tN\_l FOR CONN. DETAILS 1 X 4 -1 X 4 #5 REBAR (TYP,) 400 3/4" PLYWOOD DECKING GLUED ATTACHED WALL SHEATHING TO X 4 3-1/4" LONG X 3/16"0 FURRING 3/16"0 X 3" LONG FURRING 3/16"0 X 3-1/2" LO NG TAPCONS f FURRING #5 REBAR *404 AND NAILED W/ 8d COMMON @ 6" O.C. EDGES AND 12" O.C. FIELD 2X BOTTOM PLATE W/ 8d @ 4" O.C., 2 ROWS STAGGERED TAPCON. INTO IG TAPCONS STAG ERED STAGGERED @ 16" X 2X8 (TYPI) BLOCK@ SPACING 1 DETAIL jr O.C. 2-ROWS INTO lX8 P.T. STAGGERED @ 16" O.C. 2-ROWS INTO lya lX8 PER MANUFACTURE MASONRYTHROUGH 1-1/211 DETAIL MASONRYTHROUGH 311 DETAIL STD. 90A 90- HOOK (TYP.) 2x BAND JOIST W/ FACE NAIL 10d @ TOP & BTTM CHORD, AND (8) lx4 P.T. & lx8 P.T. lx8 P.T. & 2x8 P.T. FILLSOLID BOTH CELLS HOOK (TYP.) FACE NAILS 1 Od @ TRUSS VERT. WEB A -3116"x 3 -1/2" TA N TAPCON @ 16" Co4 ' L�J/_J/[ METAL SEAT PLATE 0 C FR O.C. & 4" FROM I lX4 P.T.— -1/211 DOOR JAMB (REFER 3/16" x 3 r r 1/2" DRYWALL NOTE: CH END A DOOR JAMB (REFER EACH END W/ MIN, KlFOR DOOR JAMB (REFER TAPCON TO SHT. SDW2-Kl FOR X4 X LAP SHEATHING TO BOTTOM OF BAND 2" EDGE DIST. TO SHT. SDW2-Kl 2 EDGE DIS 4E TO SHT. SDW2-Kl CONN. DETAIL 4% JOIST TYPICAL FOR CONN. DETAILS FOR CONN. DETAILS 1 Od @ 12" O.C. 2"/0 C MqpT lX4 4%, I FURRING 3 1 6 'o X 3- 2X8 P.T. WITH 3/16"0 X 3" LONG TAPCONS 4S ±2- - N TC No FIRST COURSE USP HGAM10 @ 12" O.C. w/4-SDS 1/4xl 1/2" SCREWS INTO BAND 2x P.T. AS REQlD .2 yj 2X8 P.T. STAGGERED @ 16" O.C. 2X8 JOIST & (4) 3/16"xl -3/4" WEDGE 2x DETAIL 2 1/4" DETAIL 2-ROWS INTO MASONRY 3-1/4" DETAIL NOTCH WEB AT THE FIRST 2 COURSES BOLTS INTO K.O. BLOCK BUILDOUT @ OVER SIZE DOOR -WINDOW ROUGH OPENINGS/'*'C�C FILLED CELL PER FOUNDATION PLAN FILLED CELL INSTALLATION � �H RETROFIT FOR MISSING EMBEDDED STRAP SCALE: N.T.S. �s SCALE: N.T.S. SEE TYP. 2-STORY WALL SECTION FOR ADDL. INFO SCALE: N.T.S. 2x8 P.T. BUCK -CONNECT TO BLOCK SECTION A -A UPLIFT CAPACITY = 945 # FOR 1 STRAP W/ 1/4" x 3 1/4" TAPCON (1 1/4" MIN. = 1890 # FOR 2 STRAPS FILL 1 st 4 COURSES EMBEDMENT INTO BLK.) 1/4" MAX z 8" 1 -PLY PRE-ENGINEERED TRUSS SOLID W/GR OUT ir 1 X 4 FURRING SOLID BLKG. AT TOP BTWN. ARCH BLKG. & BUCK 1/4" x 3 1/4" TAPCONS USP RT1 6M W/ (8) NAl 1 NAILS & (6) 1" x 2j" BLOCK HEADER TAPCONS 1/2" DRYWALL (IF TRUSS IS 2 PLY INSTALL USP HTWM16 Wl (6) 10d NAILS x *NAILS AND 8d NAILS AT 8"O.C. AT BUCK (4) J" X 1 J" WEDGE BOLTS (1) STRAP 1225 A 2 x 8 45 DIAGONAL (4) 10d NAILS INTO INTO —LEAVE A CUT OUT IN O.S.B. ON THE (2) STRAPS 2450#]) BRACE(S) 2 x 8 BRACE/ BLKG. BLKG 7A INSIDE TO ALLOW FOR INSULATION 7/16"OSB TO BE INSTALLED BOND BEAM OR CAST FOR OVERHANGS BETWEEN OVER 11/2" CUT HOLE IN O.S.B. FOR BUILT UP PLWD. BUCK ARCH PANEL OLEIN S jB - FOR i O� S POLY CELL IN THIS AREA ---2 x 8 45 DIAGONAL BRACE AT EA. IN PLACE BEAM CONTACT ENGINEER OF RECORD FOR 1. 1 1 FURTHER INSTRUCTIONS. SCRIBE (NOTCH) FACE OF ARCH W/ (3) 1 Od NAILS OVERHAN I m ImTn n q BACKSIDE TO FIT ARCH (4) 1 Od NAILS INTO 2 x 8 AT EA. END RETROFIT TRUSS DETAIL CONNECT W/ 8d NAILS BRACE/BLKG. N.T.S. 2 x 4 SOLID BLKG. (FULL WIDTH OF WALL) BTWN. OSB INSTALL WDW. SCREW ANCHOR--/ ARCH FACES W (4) 10d NAILS THRU OSB INTO 2 x 8 PROVIDE TAPCON WITHIN RETROFIT WALL OVERHANG DETAIL (NTS) INTO ARCH BLKG. PER A 4" MIN. OF BRACE 2 X 4 #2 SYP SCAB TO SIDE OF INSTALLATION DETAILS -A PROVIDE TAPCON PER WDW. INSTALLATION DETAILS OR THRU TRUSS AS SHOWN FOR O.H. UP TO Z-13" FOR OVERHANGS BETWEEN 3/4"TO 11/2" 1-1/2" THK. OR MORE BUCK WITHIN 6" MIN, OF START OF ARCH 2X6 SYP #2 CONT. (MATCH TRUSS DEPTH DOUBLE 2X4 SCAB FOR 2'-6" TO 4'-0" O.H. START OF ARC IF TRUSSES USED) W/ (3) #6 X 41/V WOOD [NOTE: FOR OVERHANGS LESS THAN 3/4" - NO REPAIR RECI'D. 4'MAX. RAD. SCREWS @ 16" O.C. MAX. OR IF MASONRY o Iz, (2) 10d NAILS @ 8" O.C. ARCH DETAIL i WALL USE (3) 1/4" X 3 1/2" TAPCONS AT 16" TO TRUSS TOP CHORD SCALE: N.T.S. SS O.C. 12 + + + IA/ PLYWOOD SHEATHING 11-011 51-011 L L JACK TRUSS PROVIDED BY SEE + TRUSS COMPANY OR PLAN 2x6 #2 SYP @ 24" O.C. + + + T_ OlLf IN ISH FLOQ R 2 x 8 BUCK - CONNECT TO BLOCK SECTION + + BLOCKING AS WITH 1/4" x 3 1/4" TAPCON (1 1/4" MIN B-B ROOF SHEATHING ATTACHED + REQUIRED EMBEDMENT INTOI�.) PER NAILING SCHEDULE LL TO SUPPORT /4" MAX Z-011 8-1 TRUSS + SOFFIT + BAR BLOCK HEADER SOLID BLKG. AT TOP BTWN. ARCH (5) -12d NAILS + 1.011 CENTERED W/ 1 X 4 FURRING BLKG. & BUCK 2X6 TO 2X4 USP RT3A 2X4 SYP IN TOP KNOCKOUT/ EACH TRUSS 7 1 1 7 1 LL 8d NAILS @ 8" O.C. AT BUCK 2 x 8 VERT. W/ (2) 1 Od CONNECTO R CHAIR BLOCK % NAILS AT EA. END PROVIDE 2 x 8 DIAG. BRACE BTWN�, PROVIDE (2) MIN. PROVIDE 2x CONT. W/ (3) SLI_ ir MONO FOOTING SIZE AND REINF. PER PLAN VERT. BRACES WHEN HGT. OF TAPCON AT EA. SIDE BUCK - (1) WITHIN 4" 12d NAILS SEE LINTEL AND SECTION DETAILS BRACE EXCEEDS 24" 7 JACK TRUSS PROVIDED BY--/ SCHED. LEAVE A CUT OUT IN O.S.B. ON T MIN. OF START OF TRUSS COMPANY OR 2X4 % CLEAN FILL 2 x 8 VERT. BRACE(S) INSIDE TO ALLOW FOR INSULATION ARCH #2 SYP @ 24" O.C. IT DIRT 2� TO BE INSTALLED 2 BUILT UP PLWD. BUCK - 4#4' MAX SEE PLAN PRECAST LINTEL ffTANDARD b SCRIBE (NOTCH) BACKSIDE 7/16" OSB ARCH PANEL 2X4 SYP #2 CONT. (MATCH TRUSS DEPTH % SEE ELEVATION #5 BAR IN H K 04 go. 00 TO FIT ARCH CONNECT W/ IF TRUSSES USED) W/ (2) #6 X 41/V WOOD FOR OVER HANG FILLED C�El_ 8d NAILS "-2 x 4 SOLID BLKG. (FULL WIDTH OF WALLS) START OF ARC 4'MAX. RAD. SCREWS @ 16" O.C. MAX. OR IF MASONRY '(MAX. 4'-0") L, V VL, BTWN. OSB ARCH FACES W/ (4) 10d NAILS EQUAL EQUAL WALL USE (2) 1/4" X 3 1/2" TAPCONS AT 16" Ll % V,.i V I Vw;., V INSTALL WDW, SCREW_"___� THRU OSB INTO 2 x 8 O.C. o .. ANCHOR INTO ARCH BLKG. FOOTING SIZE PER INSTALLATION DETAILS ARCH DETAIL rK SECTION @ ENTRY SECTION @ ROOF EXTEN SION STEMWALL AND REINF. PERLAN AND STEMWALL B-B MONO TO STEMWALL FOOTING SCALE: N.T.S. SCALE: 3/4" V-0" \�ll �s SCALE: 3/4" V-0" � �s SCALE: 3/4" V-0" SECTION DETAILS GLASS BLOCK INSTALLATION NOTES NOTE: IF RETROFIT FILLED CELL CONDITIONS A) COVER SILL AREA WITH A HEAVY COAT OF ASPHALT EMULSION. ALLOW EMULSION TO DRY EXCEED (3) PER PROJECT, CONTACT ENGINEER OF RECORD AT LEAST 2 HOURS BEFORE PLACING MORTAR. B) ADHERE EXPANSION STRIPS TO JAMBS AND HEAD. MAKE CERTAIN EXPANSION STRIP FOR ADDITIONAL INSTRUCTION. EXTENDS TO SILL. MASONRY WALL. SEE PLAN FOR EXISTING BOND BEAM. C) SET A FULL MORTAR BED JOINT, APPLIED TO SILL. REINFORCING. PROVIDE LOWER D) SET LOWER COURSE OF BLOCK. MAINTAIN A UNIFORM JOINT WIDTH OF 3/8" PLUS OR MINUS HOOKED DOWEL 1/8". ALL MORTAR JOINTS MUST BE FULL AND NOT FURROWED. ALL MORTAR SHALL BE SEE SHEET D2 AND DRILL 3/4"X6" MIN. HOLE TYPE "S" OR "N". STEEL TOOLS MUST NOT BE USED TO TAP BLOCKS INTO POSITION. (PLACE EXPANSION STRIP FLOOR PLAN FOR A RUBBER CRUTCH TIP ON END OF TROWEL TO TAP BLOCK INTO POSITION.) DO NOT 20 ga. PANEL MORE INFO SET BAR IN EPDXY REALIGN, TAP, OR OTHERWISE MOVE BLOCK AFTER INITIAL PLACEMENT. FOR SOLID GLASS ANCHOR HTT16W/(18)-16d NAILSTO CAP TO PREVENT LEAKAGE BLOCK IT MAY BE NECESSARY TO USE WEDGES IN THE MORTAR JOINTS OF THE LOWER "SQUEEZED" W , W , M , AT PERIMETER STUDS & (1) - 5/8" DIA. ALL ____k COURSES TO PREVENT THE MORTAR FROM BEING OUT. /4�' EXPANSION BOLT (2 WHERE THIS CONDITION #5X6'EMBEDDED INTO E) INSTALL PANEL REINFORCING IN EVERY OTHER MORTAR BED HORIZONTALLY AND IN JOINTS 9 ga. PANEL PERANCHOR) (1) #5 BARS CONT, TOP WITH MIN. 3" OCCURS THREAD ROD EPDXIED W/ SIMPSON "SET" EPDXY MIN. z A IMMEDIATELY ABOVE AND BELOW ALL OPENINGS WITHIN PANELS. (THE SAME SPACING REINFORCING COVER 61-0" 5" EMBEDMENT & 3" MIN. 0 cn SHALL APPLY TO PANEL ANCHORS WHEN USED AT JAMBS AND HEADS IN LIEU OF CHANNEL (EVERY OTHER e-F.F. EDGE DISTANCE < FILL CELL FULL HEIGHT W/ OR CHASE SURROUNDS.) RUN REINFORCING CONTINUOUSLY FROM END TO END OF PANELS. COURSE) EXPANSION STRIP U uj NON SHRINK GROUT. LAP REINFORCING NOT LESS THAN 6 INCHES WHENEVER IT IS NECESSARY TO USE MORE 0 2 rA THAN ONE LENGTH. DO NOT BRIDGE EXPANSION JOINTS WITH REINFORCING. INSTALL uj _j a. REINFORCING AS FOLLOWS: a. PLACE LOWER HALF OF MORTAR IN BED JOINT. DO NOT FURROW. SEALANT u- 5X6'EMBEDDED INTO PRESS PANEL REINFORCING INTO PLACE. 6" MIN. LAP SPLICE W/ EXISTING FOOTING 24 X 'IN ONC, COVER PANEL REINFORCING WITH UPPER HALF OF MORTAR BED AND TROWEL REINFORCING PANEL FILLED CELL SMOOTH. DO NO FURROW. CN DRILL 3/4"X6" MIN. HOLE F) PLACE FULL MORTAR BED FOR JOINTS NOT REQUIRING PANEL REINFORCING - DO NOT GRADE SET BAR IN EPDXY FURROW. MAINTAIN UNIFORM JOINT WIDTH. 6" MIN. LAP) G) SET SUCCEEDING COURSE OF BLOCKS. SPACE AT HEAD OF PANEL AND JAMBS MUST SPLICE REMAIN FREE OF MORTAR. NOTE: H) STRIKE JOINTS SMOOTH WHILE MORTAR IS STILL PLASTIC AND BEFORE FINAL SET. AT THIS SEE GLASS BLOCK INSTALLATION NOTES. TIME RAKE OUT ALL SPACES REQUIRING SEALANT TO A DEPTH EQUAL TO THE WIDTH OF THE SEALANT "o SAW CUT SPACES. REMOVE SURPLUS MORTAR FROM FACES OF GLASS BLOCKS AND WIPE DRY. GLASS BLOCK DETAIL (2) #5 REBAR. MIN. 3" TOOL JOINTS SMOOTH AND CONCAVE, BEFORE MORTAR TAKES FINAL SET. (REMOVE WEDGES FROM LOWER COURSES OF SOLID BLOCKS AND POINT THE VOIDS WITH MORTAR.) GLASS BLOCK SHALL BE INSTALLED PER THE FLORIDA BUILDING CODE RESIDENTIAL SECTION R160 16" M IN. COVER EA. WAY SECTION 1) AFTER FINAL MORTAR SET (APPROX. 24 HOURS), INSTALL PACKING TIGHTLY BETWEEN 7r EXISTING FOOTING GLASS BLOCK PANEL AND JAMB AND HEAD CONSTRUCTION. LEAVE SPACE FOR SEALING. 1-1-1 � SCALE: N.T.S. J) APPLY SEALANT EVENLY TO THE FULL DEPTH OF RECESSES IN ACCORDANCE WITH THE SECTION AT DEEP MONO FOUNDATION RETROFIT FOR MISSING MSTAM STRAP MANUFACTURER'S APPLICATION MANUAL AND INSTRUCTIONS. RETROFIT FILLED CELL DETAIL K) A MAXIMUM OF 60 SQUARE FEET OF GLASS BLOCK MAY BE INSTALLED IN ANY OPENING. SCALE: 3/4" = V-0" SCALE: 3/4" = V-0" FOR WIND SPEEDS UP TO 110 MPH', PER PITTSBURG CORNING RECOMMENDATIONS FOR SCALE: N.T.S. INSTALLATION OF GLASS BLOCK. (D z z co z < V) (1) (D c—n 4--J 0 Lu C) uj i2f E 0 U) cn CROSS BRACING DETAIL (TYP.)r SCALE: 1/2" V-0" TRUSS NOTES: CONV. FRAMED RIDGE 1. WOOD TRUSS ERECTOR SHALL PROVIDE BRACING ACCORDING TO ANSI/TPl-2002 MAY BE NAILED (TRUSS PLATE INSTITUTE) NOTE THAT THE COMBINED WIND AREA IS GREATER W/ MIN. (4) 12d WHEN BEFORE THE ROOF SHEATHING IS APPLIED, AND BRACING SHALL THEREFORE BE IT LANDS NEXT TO INSTALLED AS THE TRUSSES ARE ERECTED. INADEQUATE BRACING IS THE MOST PRE-ENG. TRUSS--i COMMON CAUSE OF ACCIDENT IN WOOD TRUSS CONSTRUCTION. FULL BUNDLES OF PLYWOOD SHALL NOT BE PLACED ON TRUSSES. THIS CONSTRUCTION LOAD SHOULD BE LIMITED TO 8 SHEETS OF PLYWOOD ON ANY PAIR OF TRUSSES & SHALL BE LOCATED ADJACENT TO THE SUPPORTS. NO EXCESS CONCENTRATION OF ANY CONSTRUCTION MATERIAL (SUCH AS GRAVEL OR SHINGLES) SHALL BE PLACED ON THE TRUSSES IN ANY ONE AREA THEY SHALL BE SPREAD OUT EVENLY OVER A LARGE AREA SO AS TO AVOID OVERLOADING ANY ONE TRUSS. 2. ALL BRACING (DB,CB,BB) SHOWN ABOVE SHALL BE IN ADDITION TO CONTINUOUS LATERAL BRACING SPECIFIED BY THE TRUSS MANUFACTER ALL LATERAL BRACING SPECIFIED BY TRUSS MANUF. SHALL HAVE ADDITIONAL DIAGONAL BRACES AT 201-0" O.C. MAXIMUM. 3. ALL BRACES SHALL BE 2X4 NOMINAL DIMENSION LUMBER & SHALL BE ATTACHED W/ 2-16D 4. ADDITIONAL BOTTOM CHORD BRACING SHALL BE INSTALLED AS REQUIRED BY TRUSS NAILS AT EACH TRUSS INTERSECTION. DESIGN WHEREVER ADEQUATE STRUCTURAL CEILING ARE NOT ATTACHED DIRECTLY TO THE BOTTOM CHORD OF THE TRUSS. 5. PROVIDE TRUSS BLOCKING AT ALL TRUSS BEARING SUPPORTS WHERE TRUSS DEPTH EXCEEDS STANDARD HEEL HEIGHT. SEE TYP. TRUSS BLOCKING DETAILS 2X4 BLOCKING 2X4 DIAGONAL AT 8'-0" O.C. BETWEEN EA. TRUSS MAX & EACH END ALTERNATE DIRECTION TYP. A TYP. WOOD TRUSS BLOCKING DETAIL SCALE: 1/2"=V-101" WOOD WALL OR TRUSS. SEE PLAN ATTACHED PER NAILING STRUCTURAL SHEATHING SCHEDULE VARIES W1 ROOF SLOPE �--2X4 CONT. W/ (2) 16d COMMONS NAILS EACH STUD TYP. T&B - TRUSS OR ROOF SYSTEM SHEAR TRANSFER EXTERIOR. WALL SCALE: 3/4" = V-0" CB VVI r-- I vu t,%" L-r-%%al I I VY "Li TYP. HAND FRAMING ABOVE TRUSS 2X4 STUDS & PLATES AT 2'-0" O.C. EACH DIRECTION TYP. U.N.O. 2x8 BLKING. NAILED @ EACH SIDE W/ (3) 12d NAILS WHEN REQUIRED W/ (2) USP HTW20 W/ (14) - 1 Old X 1 1/2" EACH TB i 7 PRE-ENG. TRUSS CONT. ROOF SHEATHING AT TRUSS TOP CHORD AT ALL HAND FRAMED AREAS TYP. DIAGONAL AT 81-011 MAX TRUSS ROOF SEE SHEATHING PLAN -.k 2X4 BLOCKING BETWEEN TRUSSES ,E — ""j N I SHI SECT. A -A G.T. ADD 2X4 ALONGSIDE TOP CHORD WHEN REQ'D TO PREVENT PLYWOOD SPAN FROM EXCEEDING MAX 24" SPAN (EITHER SIDE OR BOTH IF REQ'D) PROVIDE 2X4 MIN. BLOCKING AT Q OF HIP/RIDGE, TYP.BETWEEN TRUSSES W/ (2) 12D NAILS EACH END TO TRUSS TOP CHORD TYP, TRUSS �'A (2) 12D NAILS AT 12" O,C. MAX HIP/RIDGE BLOCKING DETAIL SCALE: 1/2"=11'4' VERTICAL SCAB 2 x 6 #2 SPF 48" O.C. W/ (4) 1 Od TOP & BOTTOM OR USP RT7 OR HCLR/LL W/ 8 - 8d IN PLACE OF (4) 10d COLLAR TIE EVERY 3rd RAFTER 2X4 SPF 2 (2) #7X 3-1/2" WOOD SCREW EACH TRUSS OR USP RT7 @ 48" O.C. BEVEL CUTS (OPTIONAL) * 2x8 #2 SPF RIDGE BEAM * * 2x6 #2 SYP RAFTERS FOR SPANS 4FT TO 8FT 2X4 RAFTERS FOR SPANS LESS THAN 4FT @ 2'-O"O.C. MAX. W/ (3) 10d COMMON TOENAILS TO RIDE BEAM 2X4 CONT. AT--/ CONC.MASONRY T & B CHORD STEEL OR WOOD BEARING SUPPORT A -A ALTERNATE BLOCKING DETAIL @ INTERIOR BEARING SCALE: 1/2"= V-0" PROVIDE BLOCKING AT ALL TRUSS BEARING SUPPORT WHERE TRUSS DEPTH EXCEEDS STANDARD HEEL HEIGHT VARIES ...... x ROOF SHEATHING ATTACHED PER NAILING SCHEDULE 2x4 #2 SPF BRACING @ 16" O.C. W/ (4) 12d COMMON TRUSSES. TOENAILS TO TOP SEE TRUSS PLAN PLATE & (2) 12d END MIN. (2) 2X4 FOR CONNECTION NAILS TO TRUSS SPFTOP FPLATE INFORMATION. BOTTOM CHORD Al 7A dkVARIES SEE PLAN FOR WALL LOCATION MIN. 2X4 #2 SPF STUDS @ 16" O.C. W/ EXTERIOR SHEATHING ATTACHED PER NAILING SCHEDULE & (3) 12d TOENAILS TO SEE PLAN FOR PLATE BELOW TOP OF WALL MIN. 2X4 #2 SYP P.T. PLATE W/ 1/2"X8" EPDXY ANCHOR MASONRY WALL SEE @ 3" FROM EACH END & PLAN FOR MORE 16" O.C. MAX. INFO. SECTION @ ENTRY SCALE: 3/4" = V-0" USP LSTA18 CENTERED @ SPLIT TO TIE BEAMS TOGETHER SEE FLOOR PLAN FOR COLUMN SIZE & ADDITIONAL INF( HIP G.T USP HD4101F BUCK -- SEE ROOF PLAN Fi MORE IN (2) 2x8 #2 SYP VY 7/16" O.S.B. FLIT PLATE TOP @ TI BRG. TYPIC WALL NOTE: PENDING BEAM BEARING LOCATION, THE BEAM CAN SIT ON TOP OF COLUMN W/ (2) HTW20 STRAPS USP JUS46 OR JUS461F BUCKET TO COLUMN SUPPORT COLUMN BUILT-UP (2)-2x4's OR 4x4 W/ (2)-1 Od NAILS @ 8" O.C. EACH PLY (SHOWN AS 4 x 4) (2) USP HTA20's w/(1 0)-1 Od x 1 1/2 EA. TO COL. ALT: (2) USP MSTAM36 STRAPS CENTERED w/(l 3)-1 Old NAILS Ea TO COL. TIE BEAM BEAM RAISED ENTRY MASONRY WALL r4 SCALE: 1/2" V-0- kSEE PLAN FOR CANT f SEE FLOOR PLAN FOR COLUMN SIZE& BASE 7/16"OSB FLITCH PLATE CONNECTION INFO REQ'D ONLY WHEN INDICATED ON BM. SCHEDULE/PLAN 7/16" OSB FLITCH PLATE SEEFLOOR FOR AS ST E REQ'D ONLY WHEN COLUMN SIZZAN E & BA INDICATED ON BM. CONNECTION INFO OPTION A SCHEDLILE/PLAN OPTION B OPTION C COMMON BM. TO POST ATTACHMENT rA SEE ROOF PLAN FOR BEAM SIZE & CONNECTION INFO. USP ST18 TYP. U.N.O. SEE FLOOR PLAN FOR COLUMN SIZE & ADDITIONAL INFO. (WOOD COLUMN SHOWN) 2X4 STUDS W/ USP' SPT22 @ BASE SEE J/S6 FOR MORE INFO. A A SEE PLAN FOR SEE PLAN FOR CANT. IF INDICATED 0 0 CORNER SEE FOUNDATION L� PLAN FOR MORE INFO 5" COMMON BM. ATTACHMENT SCALE: 3/4"=V-0" EXTERIOR SHEATHING ATTACHED PER NAILING SCHEDULE 2X4 BASE PLATE W/ USP LSTA30 OR MTW12 TO FLOOR GIRDER BELOW @ 16" O.C. SEE PLAN FOR 16" FLOOR SYSTEM --- FLOOR GIRDER SEE PLAN FOR DIRECTION CONNECTION SECTION FLOOR CONNECTION r2 2 SCALE: 3/4" = V-0" SCALE: 3/4"=V-101" SEE 1/S5 FOR ADDITIONAL OUTLOOKER INFO. ju TRUSS 1/2" PLYWOOD (2) 16d NAILS TO EACH COMMON TRUSS/ FRAMING TYP TOP & BOTTOM BM. SPLICE OVER CENTER OF POST MIDDLE F SEE PLAN FOR 8d NAILS AT VALLEY TRUSS 4" O.C. INFO. '-MASONRY WALL BELOW: USP HTA1 6 @ 4'-0" O.C. TO GABLE MASONRY WALL A. TRUSS BEAM BELOW: USP OR BEAM HTW20 @ 4'-0" O.C. TO GABLE SEE TRUSS PLAN TRUSS COMMON TRUSS SEE ROOF PLAN FOR CONNECTION SECTION AT HIP GABLE rj_2-� SCALE: 3/4" = V-0" EXTERIOR ATTACHED SCHEDULE KNEEWALL 2X4 #2 SYP NAILER. NAIL TO STUDS W/3-16d @ EA. STUD. TOENAIL EA. TRUSS TO NAILER W/3-10d JACK TRUSS (AS SHOWN) OR GABLE END SEE TRUSS LAYOUT CLIP EACH TRUSS (SEE ROOF PLAN FOR TYPE) FRAME OUT TO BLOCK EDGE SEE DETAIL 4/D1 FOR BEAM SIZE 2x SPF #2 AT 16" O.C. BUILDER FRAME RADIUS AS REQUIRED ENTRY FRONT WALL SCALE: 1/2"= V-0" USP JU26 OR IF 2 PLY TRUSS USP JUS26-2 TRUSS TO LEDGER 2X8 #2 SYP CONT. LEDGER W/ (4) 16d NAILS ATTACH NAILS INTO END OF EACH FLOOR TRUSS, 24" O.C. MAX. (AT EACH SIDE OF G.T. INSTALL (4) NAILS EACH SIDE) ROOF AND EXTERIOR SHEATHING ATTACHED PER NAILING SCHEDULE SEE 2ND FLOOR WALL SECTION FOR ADDITIONAL INFORMATION SEE FLOOR FRAMING PLAN AND J/S6 FOR MORE INFO. VERIFY WITH PLAN FOR LOCATION AND DIRECTION (IF PARALLE SEE 202 FOR BLOCKING INFO) -MASONRYWALL (TYPICAL) SECTION AT LOW ROOF SCALE: 1/2" V-0" LOW ROOF/WAL L SHEATHING ATTACHED\ PER NAILING SCHEDULE 2x STUDS @ 16" O.C. W/ USP SPT22 @ BASE & SPT24 @ TOP 2x BLOCKING BETWEEN STUDS TO TRUSS W/ (2) 12d TOENAILS EACH END (BETWEEN TRUSSES (2) 12d NAILS TO EACH VERTIVAL STUD) 2x BASE PLATE W/ (2) 12d NAILS @ 16" O.C. ALONG W/ USP MTW12 TO BLOCKING BELOW @ 16" O.C. PLYWOOD FLOORING LOW ROOF TRUSS Wl--II'Z Z FLOOR G.T. (2) 2x6 BLOCKING UNDER RAISED BOTTOM CHORD 2nd FLOOR WALL W/ USP SEE PLAN EXTENSION SEE TRUSS JUS24-2 EACH END MANUF. SPEC'S FOR CONNECTIONS TO G.T. SECTION @ BUMP OUTr3q'N� SCALE: 3/4"=V-0" DETAILS & SECTIONS 0 Z z -7 I < Z 4--J LU U 0 LU E 0 Ln V) 2 g Co c14 LU E 8 as 0 co 0) C mm !2.2 cm, 000 0 � $ E U_ 00 :3 - 00 0 0) CL .19 < 0 Lo 0 -A I a U. liv T, v*1 L,,�%111111r­ ext"L x ewtk �9 Nscm na, C�5 E ro u-_ U1. , C U, W W gg C 0 1 ) N &L F 0 OFESSN To the best of the Engineer's AW",lihfdrmation, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code Sth Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. C) Z 0 1.*i :Lj CD =1 M Ln -0 z 0. -- v- 2: �5 N a) - Ln < " LL F- CL >- jn� U z a 00 < z E z LU _j C) W to "UH U) UM N 2: LO 7-1 0 z cl� b r_ Ln r"4 UJ Cf) 0 C0 2 U W WOP6 < rj r%% LU z v- N z Uj _j I T__q In V-4 I Lij 00 X: < z 2 Cal z z % 175 Uj 0 0 9 0 rn -4 CL T Ln 'NOTED 2: SCALE: AS DATE 2/24/2014 TECH: MIAMES VERSION NO 10 SHEET NO. D1 (2)- 12d GABLE END FLOOR SEE SS FOR RETROFIT (1) USP LSTA30 STRAPS BENT OVER TOP PLATE TOENAILS 2x4 TO TRUSS TOP TRUSS SEE R/S6 FOR CONNECTION INFO TO CONNECTION IF MSTAM36 CAN NOT BE INSTALLED 1 OR 2 PLY GIRDER THEN DOWN THE FACE USP SPT4 W/ (6)-1 Od X 1 1/2" TRUSS. SEE PLAN FOR OF HEADER/STUDS W/ @ 24" O.C. EXT. SHEATHING MASONRY WALL CONNECTION. (22) 10d NAILS BELOW AND ALT. (2) - 2x SPF TOP PLATE SEE FOR FLUSH W/ TOP 2 OF MASNORY & 8d BLOCKING INFO G) SEE PLAN FOR CONN. 2x CRIPPLES @ 16" O.C. (2) 2x HEADER SEE PLAN BLOCKING NAILS T/B FLANGE 0 1. APPLY SUB (3) 2x # SPF W/ (2) 12d TOENAILS T/B INTERIOR HEADER DETAILS 2xSTUDS f2x STU I U') FLOOR + ADHESIVE TO STUDS w/ 10d @ (2) - 2x SPF TOP PLATE (2) 10d TOENAILS AT EA. (1) 2x SILL PLATE W/ (2) 12dTOENAILS. 2x4 CONTACT 8" O.C. EACH SIDE )JEr END OF SILL. MAX. EXTERIOR HEADERS 71 ...... SURFACE A 2x4 #2 BLOCKING 2' U.N.O. ON PLAN 9- , OPENING WIDTH 4 FEET. (1) 2x SILL PLATE W/ (2) 12d TOENAILS. OPENING LARGER THAN 4 ft (2) 2x FLOOR SYSTEM SEE PLAN NOTE: VERIFY WITH FLOOR FRAMING PLAN FOR I -JOIST B 2x4 SIDE BRACE AT 48" O.C. IF OPENING IS GREATER THAN 4 FEET BUT NOT SILL PLATE W/ MP3 CLIPS EACH SIDE EXCEEDING 6 FEET. OR FLOOR TRUSS FOR BETWEEN JOISTS RIBBON 2X CONT. RIBBON A MP3 CLIP IS TO BE MIN (3) 2x #2 SPF STUDS @ END CORRECT BLOCKING w/ (3) 12d EA. END INSTALLED AT EA. END OF HEADER SEE Q/S4 FOR REQ'D G.C. VERIFY INTERIOR REQUIREMENTS TO HORIZ. L BLOCK TYPICAL BLOCK FLOOR DECK 101 JAMB INFO (2) USP MSTAM36 STRAPS w/ (8) 10d 1/2" GYP. BOARD OR EXTERIOR STRUCTURAL I 1-1/8" RIM BOARD BLOCKING WALL ASTRAP(S) t 2x CRIPPLE AT EA. USP LSTA 30 w/ (11) - 1 Od END OF OPENING TO STUDS ABOVE PLATE NAILS & (5) Y4" x 2 Y4" TAPCONS z�_ SHEATHING (MIN. 7/16") FLOOR TRUSS/ NAILED TO STUD CENTERED ON FLOOR SYSTEM TO __7 VERIFY W/ PLAN 8d NAILS @ 3" O.C. IS JO T SEE PLAN (2) USP MSTAM36 ST P(S) I -JOIST SEE PLAN PACK w/1 Od NAILS FLOOR DECK MASONRY WALL BELOW. CONTRACTOR 7T MAY USE (2) SIMPSON MSTAM36 STRAPS WALL SHEATHING (2) - 12d TOE NAILS TOP CENTERED W/ (8) 10d NAILS TIE BEAM @ 8"o.c. FLOOR TRUSS/ I -JOIST SEE PLAN w/ (7) 1 Od NAILS & (4) Y4" x 2 Y4" TITENS TO RIM BOARD & BOTT. CHORD & (5) 1/4 TAPCONS. USP LSTA30 FROM INDOW INSTEAD OF USP MSTAM36 STRAPS. IF SCALE: 11/2" V-0" AJS BLOCKING PANEL @ 24" CONTRACTOR MAY USE JAMB TO FLOOR TRUSS/ SOLID WOOD WALL IS BELOW USE (2) MSTA36 SCALE:3/4" = V- 0" GABLE END RIM JOIST— O.C. (MAX) AND @ EACH SIMPSON (2) MSTAM36 W/ (7) PROVIDE BLOCKING BLOCKING BELOW. STRAPS w/ (22) 1 Od NAILS OR (2) SEE SS FOR RETROFIT SEE R/S6 FOR END OF WALL UNDER 1 Od NAILS & (4) X"XZY4" TAPCONS BELOW JAMBS SEE 8/D-2 FOR ALT. CONDITION. DETAIL TO BE SIMPSON MSTA36 STRAPS w/ (26) 10d CONNECTION IF MSTAM36 CONNECTION INFO TO CORNERS INSTEAD OF USP STRAP. FOLLOWED IF DOWN SET OR BOX HEADER IS USED NAILS (G.C. TO INSURE SOLID BLOCKING CAN NOT BE INSTALLED SECTION CORNER MASONRY WALL (2) - 10d TOE NAILS EACH SIDE EITHER STRAP IS ADEQUATE OTHERWISE DETAIL CAN BE IGNORED IS INSTALLED). EITHER USP OR SIMPSON STRAPS ARE ADEQUATE FRAMING ATTACHMENT BLOCKING DETAIL GIRDER/COL. CONN. @ 2nd FLOOR HEADER CONN. 2nd FLOORr4 NN� SCALE: 1/2" = V-0" AS NOTED SCALE: 3/4" V-0" SCALE: 1/2" V-0" SEE Q/S4 FOR JAMB STUD USP SPT24 @ EA. STUD W/6-10d SEE SS FOR RETROFIT SEE 8/D-2 FOR ALT. CONDITION. DETAIL TO BE CONNECTION IF MSTAM36 FOLLOWED IF DOWN SET OR BOX HEADER IS USED 2x6 / 2x8 CRIPPLES @ 16" O.C. USP SPT4 W/ (6)-1 Od X 1 1/2" TO STUD & TO TOP PLATE NOTCHED @ HEADER LOCATION SEE (2) 2x8 OR (2) 2x6 TOP REQ'D TYP -7 @ 24" O.C. USP LSTA24 W/(1 8)-1 Od NAILS CAN NOT BE INSTALLED OTHERWISE DETAIL CAN BE IGNORED INFO BELOW ON CONNECTION OF PLATE SEE PLAN 1-11W CRIPPLES IF LONGER THAN 8" TALL. T_yP-A 2 - 2 x 4 SPF USP RS1 50 W/ MIN. 12" END US P SPT4 W/ (6)-1 Od X 1 1/2 SEE PLAN FOR CONN. (CONTRACTOR MAY USE RTT CLIPS) Ar r2 (�' T F TOP PLATES LENGTH ON STUDS W/ (11) 1 Old (1) USP LSTA30 STRAPS BENT @ 24 O.C. NAIL BACK LEG OF CIPPLE TO (2) 2x HEADER TO SIT NAILS TO STUDS ABOVE & (11) 1 Od OVER TOP PLATE THEN DOWN (2) - 2X SPF TOP PLATE HEADER w/ (2) 12 TONEAILS FLUSH w/ THE OUTSIDE NAILS TO STUDS BELOW. THE FACE OF HEADER/ STUDS SEE PLAN FOR SIZE 2 x 4 #2 SPF STUDS C nD USP SPT22 W/ (6)-10d TO STUD & AT 16" O.C. U.N.O. W/ (22) 1 Od NAILS (2) 2x HEADER SEE PLAN 2x6 / 2x8 WALL BEYOND SEE HEADER FLUSH TO OUTSIDE NAILING AREA (TYP.) FLOOR PLAN FOR HEADER 2) 2x HEADER (4) - 1 Od TO PLATE 5/8" A.B. @ 24" O.C. AND 6" FROM MIN (3) 2x #2 SPF STUDS @ INTERIOR HEADER SEE PLAN FOR COL. SIZE CONNECTION SEE PLAN (2) USP MSTA36 STRAPS CENTERED EACH END W/ 7" EMBEDMENT. IF AT STEP DOWN LOCATION, MIN 7" 2xSPF EMBEDMENT PAST STEP. END OF HEADER SEE Q/S4 FOR REQ'D JAMB INFO (1) 2x SILL PLATE W/ (2) 12dTOENAILS. EXTERIOR HEADERS (1) 2x SILL PLATE W/ (2) 12d TOENAILS. OPENING FLOOR SYSTEM OR w/ (22) 1d NAILS OR (2) SIMPSON MSTA36 STRAPS w/ (26) 1 Old NAILS (EITHER USP OR SIMPSON STRAPS DOUBLE 2x6 OR 2x8 TOP SEE STANDARD HEADER PLATE SEE PLAN CONNECTION DETAILS FOR MORE INFORMATION 12d NAILS AT 6" BASE PLATE USP SPT4 EACH STUD 2x CRIPPLES @ 16" O.C. LARGER THAN 4 ft (2) 2x SILL PLATE W/ MP3 CLIPS EACH SIDE 2-STY. FRAMING ARE ADEQUATE) O.C. TYP T & B C B I ED @ HEADER / JAMB CONDITION W1 (2) 12d TOENAILS T/B r_(FY-1 V FLOOR SYSTEM OR IF BUILT-UP STUDS ARE (2) - 1 Od TOENAILS AT EACH END OF BAND JOIST & BLKG. (2) 2 x #2 EWALL OR BEAM W/IN WALL SYSTEM A.B. TO BE SILL (MAX. OPENING WIDTH 4 OR LVL GIRDER SYP U.N.O. (2) - 2 x 4 SPF SPACED W/IN 6" FROM OPENINGS 2X CRIPPLE AT EACH END OF FEET). IF OPENING IS GREATER (BLOCK SOLID) AND MULTIPLE STUD PACKS TOP PLATES OPENING NAILED TO STUD THAN 4 FEET, BUT NOT EXCEEDING 6 FEET, A MP3 CLIP IS TO BE SEE PLAN FOR 2 x CONT. T & B INTERIOR HEADER PACK W/ 1 Od NAILS @ 8"0. C.— INSTALLED TO EACH END COL. SIZE (1) 2x SILL PLATE W/ (2) 12dTOENAILS. 2 x 4 #'2 SPF STUDS EXTERIOR HEADERS (1) 2x SILL PLATE W/ (2) 12d TOENAILS. TYPICAL BLOCK WALL-------, PLYWOOD ATTACHED PER NAILING SCHEDULE USP HTT45 BASE W/ 4__ AT 16" O.C. U.N.O. (2) 2x HEADER OPENING LARGER THAN 4 ft (2) 2x SILL FLOOR TRUSS/ I -JOIST SEE PLAN x % (18) 16d NAILS & %" ANCHOR BOLT W1 BOX HEADER SEE PLAN T4YP F F PLATE W/ MP3 CLIPS EACH SIDE 2x4P.T. STUDS UNDER 2nd FLOOR HEADER USP MSTAM36 STRAP(S) ­'>< CENTERED W/ (8) 10d NAILS TIE BEAM .1. MIN. 6" EMBEDMENT (2) 2x TOP PLATE (2) LSTA12 WRAPPED UP SE PLATE ARE NOT REQ'D TO HAVE & (5) 1/4 TAPCONS. CONTRACTOR MAY USE PROVIDE BLOCKING RRS "OIX AND OVER TOP PLATE 2x CRIPPLES @ 16" O.C. W/ USP SEE FOUND. PLAN FOR FTG. REQ. CONNECTIONS. ATTACH STUDS w/ (13) 12d TOENAILS T&B SIMPSON MSTAM36 W/ (7) 1 Od NAILS & (4) Y4"x2,Y4" BELOW JAMBS SPT22 & SPT24 (OR SPT4) CONNECTORS @TOP* TAPCONS INSTEAD OF USP PROVIDE (2) CRIPPLES BELOW PROVIDE EXTERIOR SHEATHING STRAP. EITHER STRAP IS SEE FOUNDATION PLAN TO ANY GIRDER TRUSS IN THIS 2 ST. INT. BEARING WALL ATTACHED PER NAILING SCHEDULE ADEQUATE FOR FTG. REQ. 2x CRIPPLES TO SITUATION. CONNECT G.T. TO FOR EXTERIOR 2 STORY WALLS ONLY. MATCHJACK STUDS W/ (2) - HTW20 TOP & (2) AND EXTERIOR r5 SHEATHING CAN STOP ONCE UNDER LOWER HEADER CONN. 2nd FLOOR STUDS BELOW HTW20 @ BASE TO HEADER ROOF. 2 STORY COL. GIRDER (IF CRIPLLES ARE LESS THAN SCALE: 1/2" V-0" SYSTEM 42 SCALE: 1/2" = V-0" ir7 8" LONG NO STRAPS ARE SCALE: 1/2" = V-0" REQ D) `—ADDITIONAL STRAPS SEE STANDARD HEADER REQUIRED AT TOP PLATE SEE SS FOR RETROFIT SEE 8/D-2 FOR ALT. CONDITION. DETAIL TO BE CONNECTION DETAILS FOR TO STUDS TO MATCH CONNECTION IF MSTAM36 FOLLOWED IF DOWN SET OR BOX HEADER IS USED MORE INFORMATION HEADER STRAPS CAN NOT BE INSTALLED OTHERWISE DETAIL CAN BE IGNORED (2) LSTA24 (2) 2x HEADER SEE PLAN SEE 8/13-2 FOR ALT. CONDITION. DETAIL TO BE FOLLOWED IF DOWN SET OR BOX HEADER IS USED (2) USP LSTA30 STRAPS US P S PT4 W/ (6)-1 Od X 1 1/2" 2x4 STUDS MIN (3) 2x #2 SPF STUDS @ END OF HEADER OTHERWISE DETAIL CAN BE IGNORED BENT OVER TOP PLATE @ 24" O.C. PER PLAN SEE Q/S4 FOR REQ'D JAMB INFO THEN DOWN THE FACE OF HEADER/STUDS W/ (22) 1 Od 2) 2x HEADER SEE PLAN DOUBLE 2x4 USP MP3 EACH END TYP. OPENINGS LESS THAN 4'-0" WIDE, (1) USP LSTA30 STRAPS BENT NAILS 2x CRIPPLES 16" O.C. MAY BE ATTACHED W/ (2) - 16d @ TOP PLATE OVER TOP PLATE THEN DOWN USP SPT4 W/ (6)-1 Od X 1 1/2" W/ (2) 12d TOENAILS T/B NAILS @ EACH END THE FACE OF HEADER/ STUDS @ 24" O.C. HEADER 10 2 WS 10d @ (2) 2x SILL PLATE W/ (22) 1 Od NAILS (2) - 2X SPF TOP PLATE MIN (3) 2x #2 SPF STUDS //,-INTERIOR (1) 2x SILL PLATE W/ (2) 12dTOENAILS. 3"0/ (2) 2x HEADER SEE PLAN @END OF HEADER. SEE EXTERIOR HEADERS STUDS @ 16" O.C. 2x CRIPPLES @ 16" O.C. INTERIOR HEADER Q/S4 FOR REQ'D JAMB (1) 2x SILL PLATE W/ (2) 12d TOENAILS. TOP SPLICE W/ (2) 12d TOENAILS T/B (1) 2x SILL PLATE W/ (2) 12dTOENAILS. INFO. OPENING LARGER THAN 4 ft (2) 2x EXTERIOR HEADERS SILL PLATE W/ MP3 CLIPS EACH SIDE (2) - 10d TOENAILS AT EACH (1) 2x SILL PLATE W/ (2) 12d TOENAILS. 2x CRIPPLE AT EACH END OF (2) - 10d TOENAILS AT EACH END OF END OF SILL (MAX. OPE 10 �NING OPENING LARGER THAN 4 ft (2) 2x OPENING NAILED TO STUD 1 SILL (MAX. OPENING WIDTH 4 FEET). ALT. HEADER ANCHOR r8 WIDTH 4 FEET). IF OPENING SILL PLATE W/ MP3 CLIPS EACH SIDE PACK W1 10d NAILS IF OPENING IS GREATER THAN 4, IS GREATER THAN 4 FEET FEET BUT NOT EXCEEDING 6 FEET, BUT NOT EXCEEDING 6 FEET, A MP3 CLIP IS TO BE MIN (3) 2x #2 SPF STUDS @ END TYPICAL BLOCK WALL A MP3 CLIP IS TO BE INSTALLED AT PROVIDE 2X4 ON SCALE: N.T.S. INSTALLED AT EACH END OF HEADER SEE Q/S4 FOR EACH END. FLOOR DECK TOP OF 2x8 TO REQ'D JAMB INFO 61 BLOCK OUT TOP 2x CRIPPLE AT EACH END OF OPENING USP LSTA30 CENTERED (2) USP MSTAM36 STRAP(S) FLOOR TRUSS/ I -JOIST SEE PLAN PLATE ATTACH NAILED TO STUD PACK W/(22) 10d NAILS CENTERED W/ (8) 1 Od NAILS 2X CONT. RIBBON W/ (2) 1 Od NAILS @ W O.C. 2x4 BEYOND W1 1 Od NAILS @ 8"o. c. FLOOR DECK & (5) 1/4 TAPCONS. TIE BEAM AGAINST 2X8 DOUBLE CONTRACTOR MAY USE 2x8 TOP FLOOR TRUSS/ WOIST SEE PLAN SIMPSON (2) MSTAM36 W/ (7) PROVIDE BLOCKING STUDS PLATE SEE PLAN FOR BEAM 1 Od NAILS & (4) Y4"x2Y4" BELOW JAMBS 2x8 STUDS 2x4 W/ 2 ROWS SIZE & CONNECTIONS TAPCONS INSTEAD OF USP NOTE: PER PLAN OF 10d NAILS STRAP. EITHER STRAP IS PLATE LENGTHS MUST BE @ 3" O.C. HEADER CONN. 2nd FLOOR ADEQUATE HEADER CONN. @ 2nd AT LEAST 4!-0" LONG. TYPICAL W/ HIGH BM r9 FLOOR [DOUBLE STRAP] TOP PLATE SPLICE DETAIL SCALE: 1/2" = V-0" SYSTEM 42 SCALE: 1/2" = V-0" SCALE: 3/4" = 1'-9' !� a (D z z z z L/) 0 4--J U 0 LU I(Dul CL, M E Ll g CD 00 t- C14 C) E 8 4) cl) ch - T : Cc C, 11, 000 MLL 0 M J9 CL 0 < 0 CD LO 0 t 0 A1 ED* 11,1*11 D*C v 0 vv ,U N N �'% . � E &0 fic" z 'Ce =0 FL �gq,jq �0_ 11 El To the best of the Engineer's knowledge, information, and e , t e structura p ans an sped ications containe w t n t ese raw ngs comp y w t t e or a u ng Code 5th Edition (2014) Residential. Engineer's signature and seal Is only for the structural engineering portions of the drawing pages bearIng Engineer's signature and seal. (D z r*-4 0 o) r-, Lf) ­ tD > (n Cn ci, t" C) N 0 0) U_ Ln 113� U CL 00 z z z LU C� W %0 g 0, Ce > Lr) 0 - F_ 2' .1, z D L0 0 LLJ 1H � z 8 r-4 C/) 06 �E U) LL 0 F— LU dog 518 < Z Ins z Uj _j T__1 Ln T_q Lij 2: Lij x < 00 M ko < Z z ca 0 Ln r%� z 5 Uj rn T-4 10L Ul SCALE AS NOTED DATE 2/24/2014 TECH: MJAMES VERSION No' 10 SHEETNO. D2 WEATHER RESISITIVE BARRIER FOLD UP WEATHER RESISTIVE BARRIER & TEMPORARILY SECURE EXTERIOR SHEATHING WEATHER RESISITIVE BARRIER SEAL TOPS OF JOIr UNDER DECKING SELF -ADHERED FLASHING (SEE DETAIL WP07) HEAD FLASHING TIE-IN INSTRUXTIONS: 1 . Cut, fold up & temporarily secure weather resistive barrier above header to allow for flashing THESE DETAILS ARE GENERIC AND installation MEANT TO SHOW GENERAL FLASHING 2. Self -adhered flashing plus head flashing under AND WATERPROOFING METHODS TO weather resistive barrier 3. Fold weather resistive barrier back over head BE USED. flashing and seal with tape Scale: NTS SELF -ADHERED FLASHING FLANGED WINDOW FLASHING INSTALLATION AFTER WEATHER RESISTIVE BARRIER WOOD FRAME CONSTR. SELF -ADHERED FLASHlh BY LAPPING DOWN OVER RIM JOIST AND UP WALL BY 6 IN. EXTERIOR SHEATHING 14 REFER TO TECHNICAL LETTER ON CHEMICAL COMPATIBILITY SELF -ADHERED FLASHING DO NOT FLASH OVER BOTTOM NAILING FLANGE SELF -ADHERED FLASHING HALF ROUND WINDOW SELF -ADHERED FLASHING DECK JOIST NOT USED NAILING FLANGE SELF -ADHERED FLASHING M ro WEATHER RESISTIVE BARRIER Rp s 47-- 1 DOOR ROUGH OPENING 3/4"-l" BEAD OF CONSTR. ADHESIVE TO BE APPLIED UNDER THRESHOLD OF DOOR AND RETURN UP JAMB 6". USE LIQUID NAIL BRAND OR EQUAL WEATHER PROOF CAULKING SELF -ADHERED FLASHING SUBFLOOR RIM JOIST SELF -ADHERED FLASHING EXTERIOR DOOR WITH DECK - SECTION A EXTERIOR SHEATHING EXTERIOR SH THINeG 3/4"-l" BEAD OF CONSTR. INSTALL SELF -ADHERED ADHESIVE TO BE APPLIED UNDER FLASHING JAMB & HEAD THRESHOLD OF DOOR AND RETURN IN FLASHING, SEE UP JAMB 6'. USE LIQUID NAIL BRAND ID FLANGED WINDOW OR EQUAL WEATHER PROOF CAULKING .KING (SEE DETAIL WP01) SECTION -A (SEE DETAIL WP02) SELF -ADHERED FLASHING SEAL TOPS OF JOISTS UNDER DECKING (SEE DETAIL WP07) SELF -ADHERED FLASHING EXTERIOR DOOR WITH DECK SHEATHING SELF -ADHERED FLASHING 3" MIN - SELF -ADHERED FLASHING, EXTEND A MINIMUM 6" VERTICALLY FROM BOTTOM OF THRESHOLD SELF -ADHERED FLASHING PATCH SELF -ADHERED FLASHING SELF -ADHERED FLASHING OUTSIDE CORNER NOT USED 41T ri i cm) RED FLASHING APER kTH SELF -ADHERED FLASHING CEMT. FINISH SILL/ POTSHELF/ CHIMNEY SHOULDER MECHANICALLY FASTEN IF RUBBERIZED RUBBERIZED ASPHALT NEEDED IN CORNERS ASPHALT ADHESIVE ADHESIVE THROUGH SELF -ADHERED FLASHING SELF -ADHERED FLASHING ®RN SELF -ADHERED FLASHING INSIDE CORNER Ground FOUNDATION WEEP SCREED NOT USED SCORED RELEASE PAPER FOLDING, SCORE (BEFORE RELEASE PAPER TO EXPOSE ADHESIVE AS SHOWN) 0 Water Resistant Barrier Lath Sheathing Stucco FLASHING REQUIREMENTS R612. 10 Flashing, Sealants and Weatherstripping. Flashing and sealants for exterior windows shall comply with Section R703.8. R703.2 Weather -resistant sheathing paper. One layer of No. 15 asphalt felt, free from holes and breaks, complying with ASTM D 226 for Type 1 felt or other approved water -resistive barrier shall be applied over studs or sheathing of all exterior walls. Such felt or material shall be applied horizontally, with the upper layer lapped over the lower layer not less than 2 inches (51 mm). Where joints occur, felt shall be lapped not less than 6 inches (152 mm). The felt or other approved material shall be continuous to the top of walls and terminated at penetrations and building appendages in a manner to meet the requirements of the exterior wall envelope as described in Section R703.1 Exception: Omission of the water -resistive barrier is permitted in the following situations: 1. In detached accessory buildings. 2. Under exterior wall finish materials as permitted in Table R703.4 3. Under Paperbacked stucco lath when the paper backing is an approved water -resistive barrier. R703.8 Flashing. Approved corrosion -resistant flashing shall be applied shingle -fashion in a manner to prevent entry of water into thewall cavity or penetration ofwater to the building structural framing components. Self -adhered membranes used as flashing shall comply with AAMA 711. The flashing shall extend to the surface of the exterior wall finish. Approved corrosion -resistant flashings shall be installed at all of the following locations: 1. Exterior window and door openings. Flashing at exterior window and door openings shall extend to the surface ot he exterior wall finish or to the water -resistive barrier for subsequent drainage. Flashing at exterior window and door openings shall be installed in accordance with one or more ofthe following or other approved method: 1.1 The fenestration manufacturer's written flashing instructions. 1.2 The flashing manufacturer's written installation instructions. 1.3 In accordance with FMA/AAMA 100, FMA/AAMA 200, or FMAIWDMA 250. 1.4 In accordance with the flashing method of a registered design professional. 2. At the intersection of chimneys or other masonry construction with frame or stucco walls, with projecting lips on both sides under stucco copings. 3. Under and at the ends of masonry, wood or metal copings and sills. 4. Continuously above all projecting wood trim. 5. Where exterior porches, decks or stairs attach to a wall or floor assembly of wood -frame construction. 6. At wall and roof intersections. 7. At built-in gutters. R703.6.2.1 Weep Screeds 3 1/2" shall be provided at or below the foundation plate line on exterior stud walls in accordance with ASTM C 926. A Minimum 0.01 9-inch (No. 26 GaIv. sheet gage), corrosion -resistant weep screed or plastic weep screed, with a minimum vertical attachment flange of SELF -ADHERED FLASHING PRODUCTS DETAILS TWO LAYERS OF FELT OR ONE LAYER OF HOUSE WRAP AND ONE LAYER OF FELT ARE REQUIRED BEHIND STUCCO. FBC R703.2.1 Detail Instructions Refer to the number marked as in each detail that corresponds to the numbered items in the list of instructions below: 0 1 . Install self -adhered flashing in order as shown by numbers 2. Install flashing and weather resistive barrier to form water shedding laps 3. Self -adhered flashing can be substituted for building paper 4. Split the release paper using the ripcord (Split release on demand, embedded in the adhesive layer) - for ease of installation and to minimize scodng cuts 5. Remove all release paper per standard installation instructions and adhere to substrate using a square piece of flashing material (6" x 6" Minimum) 6. Fold as shown by arrows 7. Angle of corner may vary, adjust folding of the flashing accordingly to fit tight to corner 8. Mechanically fasten as necessary Cement Plaster in accordance with ASTMC926 over wood 2nd floor h", Cement Plaster over block 1 st floor 7/8" Cement Plaster in accordance with ASTMC926 Felt backed metal lathe in accordance with ASTMC 1063 Building Paper -7/16" O.S.B. sheathing Metal Flashing Weep Screed Installed As Per Manufact. Specs. Maintain Bottom of 1 1/2" to 2" Weep Screed Above Roof Sheathing Note: The building paper and metal lath must be installed over the top of the weep screed. /00"N WEEP SCREED DETAIL \,.� SCALE: NOT TO SCALE 7/8" Cement Plaster in accordance with ASTMC926 Felt backed metal lathe in accordance withASTMC1063 Building Paper 7/16" O.S.B. sheathing Stampede or similar cauk bottom joint only Weep Screed Installed As Per Manufact. Specs. 1/2" Cementitious Decorative Finish All inside and outside comer Will need to be miter cut and caulked all butt joints need to becaulked using Stampede or sim. caulk for all 0!�G Z co - 8 (D Z 0 ID fl- u) C: V) 0 4-J LLJ M 0 U 0 LLJ -(D- V) 16 E L/) I- ( CN 0 M UJ E 8 cm M M Ooo g:E U_ co :3 - co 0 cc -19 (D g < 0 0. LO �:o A 1. RD A SAO C, 1W C) 009 - Z r- N 0 Z 00 _J 0 0 r- 11- 5 rL 0 44 vim U_ _J U_ a I . C& - Z 0 - (00) :3 0 Cr Ul 4 C C� 6 Z E :9 C) < 04 C"I _J To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code 5th Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. 0 C:, Z 0 �-4 &J CD Ul 1 5) %D > Ln in I .. 4 rn p 0 .6r N tn M Ln < -0 Z CL w . r- 1q" V) 0 N CL) - Lr) C3 U_ 31 0. 00 Z . Z E Z WLLj C� F- _J C) 0i Z gc H s OWO WLU U 9 6 U) Uff < Z Ln LU Z LL 2: W Ln 0 0 Z < U LlJ LW < t5 6 9 6 t-4 Z Z LLJ Lij _J LLJ 2: < Z 00 Ln r�l Z Z 5 LU 0 rn T-4 a- Ul) SCALE AS NOTED DATE 2/24/2014 TECH: MIAMES VERSION NO 10 SHEET NO. W P Q) r_ Cl) -Fu (3) -0 > C) G) 0 Z3 < USP Connectors > Cross Reference CL C) USP Florida Statewide Evaluation Report Simpson Florida Statewide Evaluation Report CD_ 0 Stock No. Product Approval No. Basis Stock No. Product Approval No. Basis A3 I'Ll 7244.1 ESR-3455 A23 FL104 46.2 ESR-2606 HD210-2 F L 17232.3 ESR-3445 HU210-2 FL10655 20 ESR-2549 :3 Cf) _0 0 HD212-2 FI-172323 ESR-3445 HU212-2 FL10655.23 ESR-2549 0 Q HD216 FL17232,3 ESR-3445 HU216 FL10655.29 ESR-2549 L_ 0 _C) HD216-3 FL17232+3 ESR-3445 HU216-3 FL10655.29 ESR-2549 PRODUCT APPROVAL SPECIFICATION SHEET (__ -0 " HD26 FL172321 ESR-3445 HU26 FL10655,31 ESR-2549 As required by Florida Statute 553.842 and Florida Administrative Code 9B-72, please provide the information and approval numbers on the building components listed below if ICU 0 4- CZ 0 > HD28-2 FL17232.3 ESR-3445 HU28-2 FL10655.34 ESR-2549 they will be utilized on the construction project for which you are applying for a building permit. We recommend you contact your local product supplier should you not know the U) 0 HD410 FL 17232 4 ESR-3445 HU410 FL10655 44 ESR-2549 product approval number for any of the applicable listed products. L --- �Q_ C/) CL HD412 FL17232 4 ESR-3445 HU412 FL10655.45 ESR-2549 0- HD610 FL17232.4 ESR-3445 HU610 FL10655.51 ESR-2549 Category/Subcategory Manufacturer Product Description Approval Number(s) Test Pressures HD0410 FL 17241.5 ESR-3444 HUC0410 FL 11468.11 SIM200804 1. EXTERIOR DOORS HGA10KT FL17236.6 ESR-3448 HGA10KT FL1 1470 4 SIM200803 A SWINGING ThermaTru Smooth -Star and Benchmark FL15225,5 +67 0/-67.0 psf HGAM10KT FL176991 Evaluation Report HGAM10KT FL1 1470 4 SIM200803 ThermaTru Premium, Construction Series and Benchmark FL15225,6 +47 0/-47.0 psf ThermaTru Fiber Classic / Smooth Star FL15000.1 +55,0/-55,0 psf HHCP2 FL17236 7 ESR-3448 HCP2 FL10447.2 ESR-2551 HTA16 FL17680,2 Evaluation Report HETA16 FL 11473.5 SIM200802 B SLIDING General Aluminum Company Series 420/430 FL15332.1 - FL15332 5 +40+01-40 0 psf HTA20-18 FL17680,2 Evaluation Report HFTA20 FL11473 5 SIM200802 C SECTIONAL Clopay Building Products Residential WndCode Doors W5 (BX7) FL15279.37 +30,0/-32 0 psf HTT16 FL17324.1 Evaluation Report HTT16 FL114961 ES-0130 Clopay Building Products Residential WindCode Doors W5 (16X7) FL15279.53 +30.0/-30 0 psf HTT45 FL17324.1 Evaluation Report HTT22 FL114961 ES-0130 Clopay Building Products Residential WndCode Doors Wr) (8X7) FL15279.85 +38.0/-42 0 psf HTT4 1`1_17219�2 ER-0200 HTS16 FL10456 22 ESR-2613 Clopay Building Products Residential WindCode Doors W6 (16X7) FL15279.102 +37,0/-41,0 psf HTT5 FL17219 2 ER-0200 HTS20 FL10456.23 ESR-2613 D. METAL LOUVERED DRS Curries Division of AADG, Inc 607,707,727,747,and 847 Single & Pairs of Doors FL11537 1 N/A (see inst sht) HTW16 FL17244.8 ESR-3455 HTS24 FIL10456.24 ESR-2613 HTW20 FL17244.8 ESR-3455 HTS30 FL10456.26 ESR-2613 2. WINDOWS HTW24 FL17244.8 ESR-3455 HTSM16 I'Ll 1473.11 SIM200802 A SINGLE HUNG General Aluminum Company Series 1550/1570 FL15217.4 - FL15217.5 +50 01-55.0 psf HTW30 FL17244,8 FSR-3455 HTSM20 I'Ll 1473.11 SIM200802 General Aluminum Company Series 1900/1970 FL15217 7 - FL15217.9 +40.01-50 0 psf HT" 16 FL6223 2 Evaluation Report HGT2 FL10456.18 ESR-2613 B HORIZONTAL SLIDER General Aluminum Company Series 1580/1590 FL15288 I - FL15288.2 +40.0/-50 0 psf HTWM20 FL6223 2 Evaluation Report HGT3 FL10456 19 ESR-2613 General Aluminum Company Series 1980/1990 FL15288.3 - FL15288 4 +40.0/-50�0 psf HUGT2 FL6223 3 Evaluation Report HUS210-2 FL10655 92 ESR-2549 C� FIXED General Aluminum Company Series 1550/1570 FL15278 4 - FL15278,5 +40.0/-40.0 psf HUGT3 FL6223.3 Evaluation Report HUS212-2 FL10655 93 ESR-2549 General Aluminum Company Series 1900/1970 FL15278.7 - FL15278.9 +40.0/-50.0 psf HUS210-2 FL1 7232.7 ESR-3445 HUS26 FL10655.94 ESR-2549 D MULLION General Aluminum Company 1445, 5347 and 5547 Vertical Mullion FL15333.7 NIA HUS212-2 F1_1 7232.7 ESR-3445 HUS28 FL10655.96 ESR-2549 E, OTHER Z HUS26 I'Ll 7232.7 ESR-3445 HUS28-2 FL10655.97 ESR-2549 HUS28 FL17232,7 ESR-3445 LU24 FL10655 103 ESR-2549 3- PANEL WALL HUS28-2 FL17232.7 ESR-3445 LU26 FL10655 104 ESR-2549 A. SIDING James Hardie Building Prod. Cemplank Lap Siding and HardiePlank Lap Siding FL 13192 1 - FL 13192 2 N/A JL24 FL17232 8 ESR-3445 LUS210-2 FL10655 107 ESR-2549 W JL26 FL172328 ESR-3445 LUS24 FL10655.109 ESR-2549 B. SOFFITS Alside Solid and Vented Soffit FL152721 - FL15272.2 +70.0/-70.0 psf JUS210-2 FL17232 12 ESR-3445 LUS26 FL10655.111 ESR-2549 C. OTHER JUS24 FL17232 11 ESR-3445 LUS26-2 FL10655.112 ESR-2549 4. ROOFING PRODUCTS MJ JUS26 FL17232,12 ESR-3445 LUS28 FL10655.113 ESR-2549 JUS26-2 FL17232.12 ESR-3445 LUS46 FL10655.118 ESR-2549 A. ASPHALT SHINGLES Certain Teed Corporation CT20 (and AR), Landmark 30/40 (and AR), FL5444 1 N/A JUS28 FL17232.12 ESR-3445 LEG3 FL10667.71 ESR-2615 XT25 (and AR), XT30 (and AR) JUS46 FL17232.12 ESR-3445 MST60 FL10852.7 LSR-2105 B UNDERLAYMENTS Tamko 151b Felt Underlayment FL12328,6 N/A KLEG3 FL1 7241.15 ESR-3444 LSTA12 FL10852 4 ESR-2105 HomeGuard Building Products, Inc ToughSkin Synthethic Underlayments FL216751 N/A KST260 I'Ll 7244,15 ESR-3455 LSTA15 FL10852 4 ESR-2105 POLYGLASS USA Polyglass roof underlayments FL5259-R26 +N/A/-622.5 LSTA12 FL17244,18 ESR-3455 LSTA18 FL10852.4 ESR-2105 C. ROOFING FASTENERS NOT USED LSTA15 F L 17244 18 ESR-3455 LSTA24 FL10852.4 ESR-2 105 D ROOF VENTILATORS Thompson Arch Metal Comp Off Ridge Vents FL5219.1 - FL5219 3 N/A LSTA18 FL17244 18 ESR-3455 LSTA30 FL10852 4 ESR-2105 Florida Metal Products, Inc Vent RV 10 FIL2075.1 N/A LSTA24 FL17244 18 ESR-3455 LSTA36 FL10852,5 ESR-2105 Lomanco, Inc DA-4 Exahust Vent FL17202.1 N/A LSTA30 FL17244.18 ESR-3455 LTT19 F L 11496.3 ER-130 O'Hagin Manufacturing, LLC O'Hagin's CloaKded Vent Tile FIL16588.1 N/A LSTA36 FL17244.18 ESR-3455 LTT20B I'Ll 1496.3 ER-130 L ROOFING TILES Boral Tile Villa 900 FL7849.24 - FL7849 26 N/A LTS19 I'Ll 7219 3 ER-0200 LTT131 FL1 1496 3 ER-130 Boral Tile Saxony 900 FL7849.13 - FL7849 16 N/A LTS206 I'Ll 7219 3 ER-0200 LTS12 FL10456.29 ESR-2613 F. OTHER LTT131 I'Ll 7219.3 ER-0200 LGT2 I'Ll 1470 7 SIM200803 5. SHUTTERS LTW12 FL 17244.8 ESR-3455 LS30 FL10446.15 ESR-2606 A STORM PANELS Global Protection Products Galvanized Steel Storm Panels FL15076.1 - FL15076 2 N/A LUGT2 FL17240.2 ESR-3447 A34 FL10446 3 ESR-2606 Global Protection Products GPP Fabric Shutter Series 2000 FL15088.1 N/A MP3 FL17244.22 ESR-3455 LTP4 FL10446.19 ESR-2606 Town and Country Industries Safety Edge Storm Panels FL12856.1 +54,0/-54.0 psf MP34 FL17244.23 ESR-3455 LS50 FL10446.16 ESR-2606 All American Shutters Galvanized Steel Storm Panels FL17869 1 N/A MP4F FL17244.24 ESR-3455 WM1416 FL10667.86 ESR-2615 6.STRUCTURAL MP5 FL17244.22 ESR-3455 MSTA12 FIL10852.8 ESR-2105 COMPONENTS MPH3516 FL17240 3 ESR-3447 MSTA15 FL10852.8 ESR-2105 A WOOD CONNECTORS/ USP Structural Conn. see chart MSTA12 I'Ll 7244.18 ESR-3455 MSTA18 FL10852.9 ESR-2105 ANCHORS Simpson Strong -Tie see chart MSTA15 FL1 7244.18 ESR-3455 MSTA24 FL10852,9 ESR-2105 B I RUSS PLATES I rW Building Components Alpine Truss Plates FL1999.1 - FL1999 4 N/A MSTA18 FL17244.18 ESR-3455 MSTA36 FL10852 9 ESR-2105 MiTek Industries, Inc Truss Plates FL2197.1 - FL2197 5 N/A MSTA24 I'Ll 7244. 18 ESR-3455 MSTC40 FL10852 11 ESR-2105 MSTA36 I'Ll 7244 18 ESR-3455 MSTC52 FL10852.11 ESR-2105 C ENGINEERED LUMBER Roise Eng. Wood Prod Versa -Lam SID FL1644.1 N/A Boise Eng. Wood Prod Wood I -Joists ALLJOIST FL1645 1 NIA MSTC40 FL17244,26 ESR-3455 MTS12 FL10456 33 ESR-2613 Weyerhaeuser Engineered lumber - TJI FL16301 - FL1630 11 NIA MSTC52 I'Ll 7244 26 ESR-3455 MTS16 FL10456,34 ESR-2613 Weyerhaeuser il-evel Rim Board. LVL, PSL, LSL FL6527.1 - FL6527 4 NIA MTW12 FL1 7244 8 ESR-3455 MTS18 FI-1045635 ESR-2613 MTW16 FL 17244 8 ESR-3455 MTS20 1`1_10456�36 ESR-2613 D MATFRIAL Cast -Crete Corp. High Strength Concrete Lintels FL158 1 N/A MTW18 FL17244 8 ESR-3455 MGT I'Ll 1470.9 SIM200803 Commercial Concrete Products, Inc. High Strength Concrete Lintels FL1774 NIA MTW20 FL17244 8 ESR-3455 MBHA3.56/11 25 FL10866,12 ESR-2616 Powers Steel, Inc. PSbox8LT, PSbox8LT(5-5/8) FL5450 1 N/A MUGT15 FL17240 5 ESR-3447 MBHA3.56/16 FL10866 12 ESR-2616 Powers Steel, Inc I PowerBOX8 Lintels I FL1 1383 1 N/A Cn NFM35X12 FL578 2 Evaluation Report HDU2-SDS2.5 FL10441 4 ESR-2330 The products listed below did not demonstrate product approval at plan review. I understand that at the time of inspection of these products. the following information must be available to the inspector on the jobsite, 11 copy of the product approval, 2) the performance characteristics which the product was tested and certified to comply with, 3) copy of NFM35X16LI FL578 3 Evaluation Report GLTV3.516 FL106678 ESR-2615 the applicable manufacturers installation requirements. Further, I understand these products may have to be removed if approval cannot be demonstrated during inspection (D PAU44 FL17239.13 ESR-3449 FGTR I'Ll 1473 2 SIM200802 PAU66 FL17239.13 ESR-3449 CS16 FL10852.1 ESR-2105 PH02A FL17219.4 ER-0200 H1 FL10456.5 FSR-2613 PHXU3516 FL17241.20 ESR-3444 H10 FL10456.6 ESR-2613 RFUS FL6223.5 Evaluation Report H10-2 FL10456,7 ESR-2613 RS150 FL17244.27 ESR-3455 H10A FI-1045&6 ESR-2613 RT15 FL17236.11 ESR-3448 H3 FL1G456 13 ESR-2613 RT16-2 FL17236,10 ESR-3448 H4 FL10456.14 ESR-2613 RT16A FL17236 10 ESR-3448 H5 FL10456.15 ESR-2613 APPLICANT SIGNATURE DAlE RT3A FL17236.11 ESR-3448 1­12�5 FL10456.11 ESR-2613 RT4 FL17236 11 ESR-3448 H2.5A FL10456.12 ESR-2613 RT5 FL17236.11 ESR-3448 H8 I'Ll 1470.3 SIM200803 R77 FL17236.11 ESR-3448 Spi FL 10456 41 ESR-2613 RT7A FL17236.11 LSR-3448 SP2 FL10456 42 ESR-2613 RT8A FL17236.11 ESR-3448 SP4 FL10456A3 ESR-2613 > SPT22 F1_17244.30 ESR-3455 SP6 FL10456,44 ESR-2613 SPT24 FL17244.31 ESR-3455 SP8 FL10456.45 ESR-2613 0 SPT4 FL17244.32 LSR-3455 SPH4 FL10456,46 ESR-2613 SPT6 FL17244.32 ESR-3455 SPH6 F1_10456A7 ESR-2613 SPT8 FL17244.32 ESR-3455 --- Z3 SPTH4 FL172".32 ESR-3455 SPH8 FL 10456 48 ESR-2613 U24 FL10655 141 ESR-2549 I'Ll 7244,32 ESR-3455 HHUS28-2 FL10655.3 ESR-2549 SPTH6 0 SPTH8 I'Ll 7244 32 ESR-3455 HHUS410 FL10655 4 ESR-2549 O_ SUH24 F L 17232 14 ESR-3445 HGUS5.25/12 I'Ll 1468 11 SIM200804 THD28 FL17232,17 ESR-3445 HGUS414 FL11468 10 SIM200804 (D THD28-2 FL17232.17 FSR-3445 HDQ8-SDS3 I'Ll 0441 1 ESR-2330 U) THD410 FL17232.17 ESR-3445 MSTAM24 I'Ll 1473 19 SIM200802 M THD412 FL17232.17 ESR-3445 MSTAM36 FL11473.19 SIM200802 M THD612 FL17232,17 ESR-3445 MSTCM40 I'Ll 1473.19 SIM200802 < THDH414 FL17232 18 ESR-3445 HHETA20 I'Ll 1473.9 SIM200802 UGTS3F FL2033A Evaluation Report LGT3-SOS2 5 I'Ll 1470.7 SIM200803 UPHD8 FL17219 6 ER-0200 LGUM26-2 I'Ll 1473 12 SIM200802 0 Lii r) < W < _J a_ SHEET NO. PA 1.0-- r Florida Department of Business & Professional Regulation Building Codes and Standards Product Approval Application Detail Page I of 2 1/912017 FLN1522543 2209 EntftV or Date 20 Date Pend Ina Date Type Venlo Manufactu Contact, Ena Ineer & Licarm Validated By Submitted E§2A22OLW Approved Status Revision 2014 Therme-Tru Corporation RickWright National Accreditation & Ryan J. King, P.E. 06/2a/2015 06113/2015 07/05/2015 Approved Category'. Exterior Doors (419) 298-1740 Management Institute (813) 767-8555 subcategory: Swinging Exterior Door Assemblies rickyv@rwbidgeonsuftents. FL81 5Z15,R3 Compliance Method: Certification Mark or Listing Products com Quality Assurance Approved for Use Approved for Use impact Deslan 3`101 Product Model, Number or Nam a Product Description Contimet Expiration Date In HVHZ Outside HVHIZ Resistant Pivasure 5 e. &quotSmooth-Star&quot, and &quc�Benchmsrk by e/8 and a10 Opaque and Glazed Fiberglass Door with 12131/2021 No Yes No N/A Therma-TnAquot and without Sidelites. Inswing and Outinving 6 f, &quotloremeum Senes&quot, &,quot'.Construction 8/8 and 8/0 Opaque and Glazed Sleel Door with 12/3112021 No Yes No N/A SerIes&qucK and &quotBanchrnark by Therma-Tru&quot Transoms, With and without Sideliles Iniewmil and with Transoms Outswing Florida Department of Business & Professional Regulation Building Codes and Standards Product Approval Application Detail FL*102TM4 22a Entity or Versio Manufacturer Contact Enalnew & License Validated By Revision 2014 Clopay Building Products Company Mark Westerfield I ntertak Testing Services NA, Approved Category. Exterior Doom (513) 770-8= Inc (513) 519-8566 Subcategory: Sectional Exterior Door Assemblies nivvesterfieldCclopay.corn Compliance Method: Certification Mark or Listing FLNJ 5279-114 Prod ucts Pagel of 1 1/912017 20 20 Date Pond Ina Date Validated Su bm Itted FBC Approval Approved Gary Pfuehler 06/1 Z12015 03/19/2015 08/21/2015 Quality Assurance Approved for Use Approved for Use Impact Design -sag X Product Model, Numbqr or Name Product Description Contract Expiration Date In HVHZ Outside HVHZ Resistant Pressure 37 037 W5-09 PAN-21`1 51: 84A, 94, 73, 75,1500, 190. 76. Steel Pan (min. 25 go.) Single -Car (up to 9'9'vAde) 05/21/2028 No Yes No +30 PSF/-32 76V, 4RST, 4RSF, ORST, ORSF, 2RST, 48. 42, 55, 48B, WI NDCODE&#1 74; W5 Garage Door PSF 428,55S, GD5S, G05SV, GR5S, GR5SV, AR5S, AR5SV, ED5S, ED5SV 53 053 M-1 6 PAN-2Fl 53: 84A, 94, 73, 75, 15W, 190, 4RST. Steel Pan (min. 25 ga.) Double -Car (97 to 16'0' 0501/2028 No Yes No +30 PSF/-30 4RSF, ORST, 6RSF, 48,42,55.48B, 42B, 55S, GD5S. wide) WINDCODE&#174; W5Garage Door PSF GD5SV, GR5S, GR5SV, ARSS, ARSSV, EDSS, ED5SV 85 086 WB-09 PAN-2F1 53: 73, 75. 84A. 94, 42, 48, 42B, 48B. 9sel Pan (rnin, 25 ga.) Sngle-Car (up to 9'0"wide) 05/21/2028 No yes No +38 PSF/-42 4RST, 6RST, GD5S, GR5S, AR5S, ED5S W NDCODE&#1 74; W6 Garage Door PSF 102 102 M-1 6 PAN-2F1 53: 73. 75, 84A, 94. 42, 48, 42B. 48B. Steel Pan (min. 25 ga.) Double -Car (97 to 162" 05/2112028 No Yes No +37 PSF/41 4RST, 6RST, GOSS, GR5S, AR5S, ED5S wide) WINDCODE&#1 74; W6 Garage Door PSF Florida Department of Business & Professional Regulation Building Codes and Standards Product Approval Application Detail Page I of 1 1/912017 F1.815288-R2 Code Entity or 21M 201 Date Pending 2da I= Versio Manufacturer Contact Enalneer & License Validated By Validated Submitted FBC Approval Approved Affirmation 2014 MI Windows and Doors Brent Sitlinger Luis Roberto Lornas Steven M. Urich, PE 04/3012015 04/3012015 05/1012015 Approved Category: Windows (717) 365-3300 PE-62514 (717) 317-8454 SubCategory: Horizontal Slider bsMinger@mhW.com Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer FL*16288-R2 Products AW Product Model. Number or Name Product Elliscription QuaittvAsaurance Contract Expiraticago Approvy2d for Use Approved In HVHZ Outside for Use HVHZ Impact 1311111111= Destan EMIM 1 SERIES GA 198 ALUMINUM HORIZONTAL SLIDER SERIES GA 198 ALUMINUM HORIZONTAL SLIDER l2f3l/2017 No yes No N/A 72)(54 2 SERIES GA 198 ALUMINUM HORIZONTAL SLIDER SERIES GA 198 ALUMINUM HORIZONTAL SLIDER 12t3l/2017 No Yes No N/A 72)34 3 SERIES GA 198 ALUMINUM XOX HORIZONTAL SLIDER SERIES GA 198 ALUMINUM XOX HORIZONTAL 12/3112017 No Yes No N/A SLIDER 108X48 4 SERIES GA 198 ALUMINUM XOX HORIZONTAL SLIDER SERIES GA 198 ALUMINUM XOX HORIZONTAL 12/31/2017 No Yes No NIA SLIDER Florida Department of Business & Professional Regulation Building Codes and Standards Product Approval Application Detail Page 1 of 2 119/2017 Florida Department of Business & Professional Regulation Building Codes and Standards Product Approval Application Detail Page I of I 1/912017 FL#15000-R2 Qft Entity or Date 20 Date Pending Do I= XilMtga Manufacturer Contact Eno Ineer & License Validated BV Validated Submitted FBC Approval Approved J'aw Revision 2014 Therma-Tru Corporation RickWright Lyndon F. Schmidt, P.E. Ryan J. King, P.E. 06/28/2015 05/29/2015 07105/2015 08/19/2015 Approved Category: Exterior Doors (419) 298-1740 PE-43409 (813) 767.M55 Subcategory: Swinging Exterior Door Assemblies rickwQrwbIdgconsultants. Compliance Method: Evaluation Report from a com F orids Registered Architect or a Licensed Florida P=ional Engineer FL#1 $000-R2 Products Quality Assurance Approved for Use Approved for Usla Im pact Design AKA Prod uct Model. Number or Nam a Product Description In HVtZ Outside HVHZ Resistant Pressure 1 a. &quot;Fiber-CIsssic&quot, or &quot;Smoc0th-St8r&quot; 6&#39;8 &quot;Non-Impact&quot; Opaque Fiberglass 12/31/2MOI yes Yes No N/A Door with &amp, without Sidelits(s) - Outswing (K OX or XO, OXO, XX, OXXO Configurations) F1.111111537-RO Code Two Versia Manufacturer Revision 2014 CURRIES Division of AADG, Inc Category: Exterior Doors SubCategory. Exterior Door Components Compliance Method: Certification Mark or Listing FLX1 1537-RS Products 22" Product Model. Number or Name 1 607, 707, 727, 747, and 847 Single and Pairs of Doors 2 M, CM, and G Series Frames Florida Department of Business & Professional Regulation Building Codes and Standards Product Approval Application Detail Entity or Contact Enalneer & License Nelson Kraschel UL LLC (641) 423-1334 nelwn.kraschelCdoorgro up.com Product Description Flush, Glazed, and Louvered single and pairs of hollow metal doors Three sided and four sided single and pairs of frames. Tansom frames. Validated By Ted Berman, PE (305) 8W4707 Page I of 1 1/10/2017 20 Date Pend Ina 20 Validated Submitted FaCAoproyal Approved status 07/2112015 07/2112015 07/27/2015 Approved Quality Assurance Approved for Use Approved for Use Impact Design Contract Expiration Date in 14VKZ Outside HVHZ Resistant Pressure 12/31t2017 Yes Yes Yes N/A 12t3l/2017 Yes Yes Yes N/A Florida Department of Business& Professional Regulation Building Codes and Standards Product Approval Application Detail Page 1 of 3 1WO17 FL#15279-R4 Code Entity or 21112 M Date Pend Ina Date Im �_ersig manufacturer Contact Enalnear & Ucertse Validated By Validated Submitted FBC Approval Approved Status Revision 2014 MI Windows and Doors Brent Sitlinger Luis Roberto Lomas Steven M. Urich, PE 09/0112015 06131/2015 09/05/2015 10/16/2015 Approved Category. Windows (717) 365-3300 PE-62514 (717) 317-8454 Subcategory. Fixed bsidinger(onliwd.com Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florda Professional Engineer FLO15278-P-4 Products AW Product Model, Number or Name Product Description 4 SER�ESGAWSALUM�NUM PW SERIES GA 195 ALUMINUM P`WNI96X48 FIN 5 SERESGA195ALUMNUM PW SERIES GA 195 ALUMINUM PWN172X72 FLANGE 7 SERIES GA 195 ALUMINUM PW SERIES GA 195 ALUMINUM PWNI96X48 FLANGE 8 SERIES GA 275 THERMALLY BROKEN ALUMINUM PW SERIES GA 275 THERMALLY BROKEN ALUMINUM PW NI 72X72 FIN 9 SERIES GA 505 ALUMINUM PW SERIES GA 505 ALUMINUM PWN172X72 FIN Quality Assurance Contract Expiration Date 1213112017 Approved for Use In HVHZ No Approved for Use Outside HVHZ yes Impact Resistant No Design Pressure N/A 1261/2017 No Yes No NIA 12/31/2017 No Yes No N/A l2f3l/2017 No yes No N/A 12131/2017 No Yes No N/A Florida Department of Business & Professional Regulation Building Codes and Standards Product Approval Application Detail Page 1 of I I/9n017 F1.031192-Ril FL*15272-Ri Code Erift o Date Daft Date Pend Ina 20 22A Entity or 219 20 Date Pend Ina Date Ve-mlo, Manufacturer Contact Engineer & License Validated By Validated Su bm fitted FOC Approval Approved 3-t at u s T­ Versio kankfal;= Contact 111WAULAI"M Validated By Validated Submitted EBC Apgroyal Approved Status Revision 2014 James Hardie Bulkling Products� Inc, Pingsheng Zhu Ronald 1, Ogaws John Southard, P.E. 08126/2015 08117/2015 09/07/2015 1 Otl 8/2015 Approved Revision 2014 Alsids NIckThompson Lyndon F. Schmidt, P.E. Ryan J. King, P.E. OX=015 02119/2015 03/01/2015 04/15/2015 Approved Category: Panel Walls (909) 349-2927 PE-24121 (352) 387-2526 Category,. Panel Walls (330) M-2389 PE-43409 (813) 767-6555 Subcategory: Siding pingsheng.zhu@jameshar SubCategory: Soffits nthompson@aiside.00m Compliance Method: Evaluation Report from a die.00m Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Florida Registered Architect or a Licensed Florida Professional Engineer Professional Engineer FL#13192-R4 Products FLA15272-Rl Products Quality Assurance Approved for Use Approved for Use Impact Desion QualltyAssurance Approved for Use Approved for Use Irn pact Daillan 11211 &W uct Model. Num ber or Nam a Product Description Contract Dpirration 21k in HV1iZ Outside HVHZ Resistant Pressure Product Model, Number or Name Product Description Contract EpKpinition Date In HVHZ Outside HVHZ Resistant Pressure 1 Complank Lap Siding fiber -cement lap siding 01101/2018 yes Yes N/A NIA 1 a. &quot;ZT&quot Soffit Vent or Solid Vinyl Soffit 1213112018 No Yes No N/A 2 HardiePiank Lap Siding fiber -cement lap siding 01/01/2018 Yes yes N/A NIA 2 b. &quot;Allianc9T4&quot, Soffit Vent or Solid Vinyl Soffit 12131/2018 No yes No N/A FLX15332-R3 Prod U01 SOQ # Product Model, Number or Name 4 SERIES 420 ALUMINUM SGD REINFORCED 5 SERIES 420 ALUMINUM SGO REINFORCED 7 SERIES 420 REINFORCED ALUMINUM SGD 8 SERIES 430/440 ALUMINUM SGD 9 SERIES 430/440 REINFORCED ALUMINUM SGD FLO15217-R4 220 I= Y2= Manufacturer Revision 2014 MI Windows and Doors Category: Windows SuloCategory: Single Hung Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer FL*15217-R4 Products §W I. Number or Nam a 4 SERIES GA 195 ALUMINUM SH 5 SER�Es GA 195 ALUMINUM SH 7 SERESGA 95ALUMINUMSH 8 SERIES GA 195 ALUMINUM TRIPLE SH 9 SERIES GA 195 ALUMINUM TWIN SH 171.11115333-R2 22" Varalo Manufacturer Revision 2014 MI Windows and Doors Category: Windows Subcategory: Mullions Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer FL#15333-R2,PM9ucts ba Produ(g Model, Number or Name 7 1445,5347 AND 5547 VER71CAL MULLION FL#5444-RIO 220 Verslo, Manufacturer Revision 2014 CartainTeed Corporation -Roofing Category: Roofing Subcategory-. Asphalt Shingles Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer FL#DW,91 0 Fr94 ucts 3-0 Product Model. NumkjLgLkWmj I CartainTeed Asphalt Roofing Shingles Florida Department of Business & Professional Regulation Building Codes and Standards Product Approval Application Detail Product Description SERIES 420 ALUMINUM SGD REINFORCED 0)� XO, )0(96&quotx96&quot; SERIES420 ALUMINUM SGD REINFORCEDXXX 143&quot &quot; SERIES =REINFORCED ALUMINUM SGD OXO 146&quot;x96&quot; SERIES430/440 ALUMINUM SGD XXX l43&quot%x80&quot% NON -REINFORCED SERIES 4301440 REINFORCED ALUMINUM SGD )O(X l43&quotx98&quot; Page 1 of 2 1/912017 Quality Assurance Approved for Use Aparoved for Use Im pact Desion Contract Expiration Date In HVHZ Outside HVHIZ Resistant Pressure 12131/2017 No Yes No N/A 12/31/2017 No Yes No NIA 1213112017 No Yes No N/A 12/31/2017 No Yes No N/A 125112017 No Yes No N/A Florida Department of Business & Professional Regulation Building Codes and Standards Product Approval Application Detail Enttty or contact Enalneer & License Brent Sidinger Luis Roberto Lomas (717) 385-3300 PE-82514 belflingerCmiwd.com Product Descricition SERIES GA 196 ALUMINUM SH NI 44X$4 SERIES GA 195 ALUMINUM SH NI 54X72 SERIES GA 195 ALUMINUM SH NI 54X72 SERIES GA 195 ALUMINUM TRIPLE SH NI CONTINUOUS HEAD AND SILL 108X72 NON IMPACT SERIES GA 195 ALUMINUM TWIN SH NI CONTINUOUS HEAD AND SILL 88 1/8X72 Validated By Steven M. Urich, PE (717) 317-8454 Page 1 of 2 1/9=17 Date 20 Daft Pendina 20 Validated Submitted fj2AWU" Approved Status 08/30/2015 06/25/2015 07/0612015 08/19/2015 Approved Quality Assurance Approved for Use Approved for Use [in pact Design Contract Expiration Pift In HVHIZ Outside HVHIZ Resistant Pressure 1261/2017 No Yes No N/A 12/31/2017 No yes No N/A 12131/2017 No yes No N/A 12131/2017 No Yes No N/A 12131/2017 No Yes No N/A Florida Department of Business & Professional Regulation Building Codes and Standards Product Approval Application Detail Entity o Contact Engineer & License Brent Sibinger Luis Roberto Lomas (717) 305-3300 PE-62514 bsitlingerCm1wd.corn Product Descriation 1445,5347 AND 5547 VERTICAL MULLION Validated By Steven M. Urich, PE (717) 317-8454 page 1 or 1 1/WO17 Date 20 Date Pending 20 Validated 1111111111M E02AWXL)ffil Approved Status 06/29/2015 06/19/2015 07/05/2015 08/19/2015 Approved Quality Assurance Approved fpr Use Approved for Use Impact Design ILH= Outside HV1iZ Resistant Pressure 12/31/2017 No Yes Yes N/A Florida Department of Business & Professional Regulation Page 1 of 2 Building Codes and Standards VW017 Product Approval Application Detail Eirtity or 20 Do Date Pend Ina 20 Contact Enalneer & License Validated BY Validated JWM= FBQ Approval Approved Mark Hamer Robert Nierninen John W, Knezovich, PE 12/14/2016 12108/2016 12J15/2018 Pending FBC Approval (610) 661-5847 PE-591 66 (954) 772-6224 mark, d, herner@sairyt-gob ain.com Quality Assurance ApprovedforUse ApprovedforUse Impact Desian Product Description Contract Expiration 5ate In HVHZ Outside HVHZ Resistant Pressure 3-tab, 4-tab, strip (no -cut-outs), laminated and 071030017 No Yes NIA N/A architectural asphalt roof shingles CD Cn -00 > 2 C D a) CL 0_ o 2 CU CL C CD =3 -0 CU 0 0 -cu 0 C 0 2 a 0 ICU 0 .0 ICU U_ 114- 0 ICU > D -0 CD US E (D CU CIO -0 1402 C - -6-0 Cn < Z Z W Mj Cn CIO 0 -*-no CIO 0 < C/) Cf) 0 ICU 2 L_ 0 CU C) -4--a u) ICU M L) L) ICU Uj < Z Z _j CL SHEET NO. PA 1, l� FL#12328-RT Products AW Product Model, Number or Name 6 No. 15 UL Florida Department of Business & Professional Regulation Page 1 of 3 Building Codes and Standards 111WO'17 Product Approval Application Detail Quality Assurance Approved for Use Aociroved for Use Impact Design Product Description In HVHZ Outside HVHZ Resistant Pressure Asphalt saturated organic fell 01/MO7/201 No Yes N/A N/A Search Criteria Code Version: 2014 FL At 12328 Application Type: ALL Product Manufacturer: ALL Category: ALL Subcategory,. ALL Application Status: ALL Compliance Method: ALL Quality Assurance Entity Contract Expired: ALL Product Model, Number or Name: ALL Product Description: ALL Approved for use In HVNZ: ALL Approved for use outside HVHZ: ALL Impact Resistant ALL Design Pressure: ALL Date From: ALL Date To: ALL FL#2075-R7 221k Versio Manufacturer Affirmation 2014 Florida Metal Products Inc. Category: Roofing SubCabagory: Roofing Accessories that are an Integral Part of the Roofing System Compliance Method: Evaluation Report from a Product Evaluation Entity FL$2075-R7 Products I ad" Product Model, Number or Name 1 RV1 0 FLOM9-R9 Code Type Verillo Manufacture Revision 2014 Boral Roofing / Monlorl-ifetile Category: Roofing SubCatogory: Roofing Tiles Compliance Method: Evaluation Report from a Product Evaluation Entity FL#7049-R9 Products S" X Product Model, Number or Narrig 13 Saxony 700 - Shake, State &amp; Split Shake 14 Saxony 900 - Country State, Shake &amp,, Slate 15 Saxony 900 - Country Sats, Shake, Slate &amp; Split Shake 18 Saxony 900 - Hartford Slate, Split Old English Thatch, Shake, Sate, Country Slate 24 villa 9W 25 villa 9W 26 Villa 900 FL#1205"5 2= Versigi Manufacture Revision 2014 Town and Country Industries, Category: Shutters SubCatsgory: Storm Panels Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer FL#120WR5 Products h2a 1 0.050&quot Aluminum Storm Panel 2 &quotSatety Edge&quot Storm Panels 3 24ga Steel Storm Panel 4 Aluminum Hinged Storm Panel Florida Department of Business & Professional Regulation Page 1 of I Building Codes and Standards 1=017 Product Approval Application Detail Entity or 2& Date Date Ponglina 21a 22= Enalnssr& License Validated By Validated Submitted ENARRMW Approved Status Clark Jones Miami -Dade BCCO - EVIL Miami-DodaBCCO-VAL O2t27/2015 02127/2015 03/09/2015 Approved (904) 783-8400 (786) 315-2590 clark@flamoo.com Quality Assurance ApprovedforUse ApprovedforUse Impact 200 Product Description Contract Expiration Date In HVHZ Outside HVHZ Resistant Pressure RV10 ALUMINUM RIDGE VENT 01/31/2018 Yes Yes N/A N/A Florida Department of Business & Professional Regulation Building Codes and Standards Product Approval Application Detail Entity 0 Contact Engineer & License Validated By Thomas Jemmett ICC Evaluation Service, LLC Gary W. Walker (802) 269-2288 (205) 854-0160 thornasjorrimetaboral.co m ftguct Description Flat Profile - Stockton Flay Profile - Henderson Flat Profile - Lake Wales Flat Profile - Stockton Medium Profile - Lake Wales Medium Profile - Denver Medium Profile - Stockton Page I of 3 1/9/2017 Date Date Date PendIna Date Validated Submitted FBC Approval Approved Status 09/10/2015 08/25/2015 09/20/2015 Approved Quality Assurance Approved for Use Approved for Use Impact Design Contract Expiration Date In KVH1Z Outside HVHZ Resists Pressure 12/31/2018 No Yes N/A N/A 12131/2018 No Yes NIA N/A 12131/2018 No Yes N/A N/A 12/31/2018 No Yes N/A NIA 125112018 No Yes N/A N/A 12/31/2018 No Yes N/A N/A 12131/2018 No Yes N/A N/A Florida Department of Business & Professional Regulation Building Codes and Standards Product Approval Application Detail Page 1 of 1 1/&2017 Efftitv or 20 20 Date Pending 291 92111M Engineer & License Validated By Validated Submitted FBC Approval Approved Status Tom Johnston Frank 1. Bennardo ORLANDO L. BLANCO, 04M/2015 04/28/2015 05104r2015 06/22/2015 Approved (954) 493-8551 PE-0046549 P.E. tomj@tc-alum.com (305) 510-8531 Product Description 0.050&quot Aluminum Storm Panel with Optional Clear Panels &quot,Safety Edge&quot; Storm Panels, 28ga (0.018&quot,&quot) Steel, 0.022&quat; Alum (Perf and Non -Pert), Clear Polycarb (Full and Hal) 24gs (0.0232&quot) Steel Storm Panel with Optional Clear Panels .050&quot, Aluminum Non -Porous Hinged Storm Panel Quality Assurance Contract Expiration Daft 1261/2018 Approved for Use In HVHZ No Apipravved for Use Outside HVHZ Yes Impact Resistant Yes Design Pressure N/A 1213112018 No Yes Yes +54/-54 12131/2018 No Yes Yes +100/-100 12/31/2018 Yes Yes Yes N/A F02`1675-110 Q992 IM yq= Manufacturer Now 2014 HomeGuard Building Products, Inc. Approved Category: Roofing Subcategory: Undedayments Compliance Method: Evaluation Report from a Product Evaluation Entity FLX21675-Ro Products AW Product Model, Number or Name 1 ToughSkin Synthetic Underlayrrients FL*17"2-Rl 22A I= yg[Wg Manufacturer Revision 2014 Lornanco, Inc Category. Roofing SubCategory. Roofing Accessories that are an Integral Part of the Rooting System Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer FL#17202-Ri Products a M" 1 Deck-Air� DA-4 2 OmniRidge&#174; PRO Vent PR04-N FL#lOQ7"3 Qft IM Verslo Manufacture Revision 2014 Global Protection Products, LLC, Category: Shutters Subcategory: Storm Panels Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer FL#15076-R3 Products a Emil! Product Model, Number or Name 1 20 Gage Galvanized Steel Storm Panels/HVHZ 2 24 Gage Galvanized Steel Storm Panels/NHVHZ ELS15076-R4 2"A I= yj= Manufacturer Revision 2014 Global Protection Products, LLC. Category: Shutters Subcategory: Storm Panels Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer FL#15076-R4 Products Ina eMuct Model. Number or Name 1 20 Gage Galvanized Steel Storm PaneIs1HVHZ 2 24 Gage Galvanized Steel Storm PaneIstNHVHZ FL01796MO 220 yq= Manufacturer New 2014 All American Shutters and Glass Category: Shutters SubCategory: Storm Panels Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida F1.81 7069-RO Professional Engineer Products S-0 Product Model, Numberior Name 1 22ga, 24ga Stael Panels Florida Department of Business & Professional Regulation Building Codes and Standards Product Approval Application Detail Page 1 of I 2An017 Entilty or 20 20 Deft Pend Ina 20 Contact Engineer & License Validated By Validated &WR= F13C Approval Approved Bawl John Choslak Intertok Testing Services NA, Intertek'resting Services 02/0112017 01/26=17 02/03/2017 (904) 240A382 Inc. NA, Inc. john.choslak@hWap.00 (604) 520-3321 m Quality Assurance Approved for Use Approved for Use Im pact Design Product Description In KVKZ Outside HVHZ 111"stant Pressure ToughSldn 15, ToughSldn 20, ToughSkin 25, 01/01/2018 No Yes N/A N/A ToughSkin 30, ToughSkin 50 Florida Department of Business 8, Professional Regulation Building Codes and Standards Product Approval Application Detail Page 1 of I 1110f2017 Entity or 20 20 Date Pend Ina 20 Contact Engineer & License Validated By Validated Submitted FBC Aigoroval AbDroved XW AndrewCarter James L. Buckner, P.E. Steven M. Urich, PE 05/0112015 05/01/2015 05/1 =015 0&=15 Approved (5011) 982-8511 PE-31242 (717) 317-8454 acarter@lomenco.com Product Descrlutlon Low Profile, Polypropylene Plastic, Roof Vent IttvAssurance Approved for Use Approved for Use I Date 11= Outside HVHZ 07/10/2019 No Yes Impact Resistant No Design Pressure +97.5/-97.5 Mechanically Attached to Plywood Dock. Molded Plastic, Roof Ridge Vent Mechanically 07/1012019 No Yes No +N/A/-1 65 Attached to OSB or Plywood Dock. Florida Department of Business & Professional Regulation Building Codes and Standards Product Approval Application Detail Pago I d 1 11912017 Entity of 20 20 Date Pend Ina 20 Contact Eno Inter & License Validated By Validated Submitted FBCApproval Allia"11111 Stattis Tim Robinson Waiter A, Tillit Jr., P.E. John W. Knozovich, PE 05=42015 0024/2015 05/11 f2015 oer""15 Approved (954) W9-7545 PE-44167 (954) 772-M4 tim.robinsonQgppent.com Quality Assurance Approved for Use Approved for Use Impact Design Product DescritMon Contract Expiration Date In HVHZ 2utside Resistant Pressure Corrugated Galvanized Steel Storm Panels retained 12/31/2017 Yes Yes Yes N/A or not by tracks to provide hurricane protection. Corrugated Galvanized Steel Storm Panels retained 12131/2017 No Yes Yes N/A or not by tracks to provide hurricane protection. Entity or 20 20 Date Pendina 20 Contact Engineer & License validated By Validated Submitted FBC Approval Approved 211111,11 Tim Robinson Walter A. Tillit Jr., P.E, John W, Knezievich, PE 1212112016 120=18 Validated (VA) 689-7545 PE44167 (954) 772-8224 tim.robirison@gppent.com Quality Assurance Approved for Use Approved for Use Impact Design Product Descriction Contract EXoIM§on 90 In HVKZ Outside HVHZ Resistant Pressure Corrugated Galvanized Steel Storm Panels retained 12/31/2017 Yes Yes Yes N/A or not by tracks to provide hurricane protection. Corrugated Galvanized Steel Storm Panels retained 12/31/2017 No Yes Yes N/A or not by tracks to provide hurricane protection. Florida Department of Business 8, Professional Regulation Building Codes and Standards Product Approval Application Detail Page 1 c(2 IIWO17 � Entitv or 20 Date Data Pending 20 Contact Eno Ineer & License Validated By Validated Submitted F5C Approval Aparoved Status Mike Barbieri Frank L. Bennardo, P,E Jorge A. Pomerantz, PE. 07/0312015 07/03/2015 07/1012015 08/1812015 Approved (561) 712-9882 PE-0048549 (954) 394-8521 mikeb(Dallemericanshutte rs.com Quality Assurance Approved for Use Approved for Use Impact Design Product Description Contract Expireflign Data In HVHZ Outside HVHZ Resistant Pressure 22gs, 24ga Steel Storm Panels 12/31Q017 No Yes Yes NIA Florida Department of Business & Professional Regulation Building Codes and Standards Product Approval Application Detail FLA2119-113 9992 Entity or Imit Veneto Manufacturer Contact Engineer & License Revision 2014 Thompson Architectural Metals Company, Inc. Scott Brown James L. Buckner Category: Roofing (813) 248-3458 PE-31242 SubCataglory: Roofing Accessories that are an flvalidetionCoyahoo.com Integral Part of the Roofing System Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida FI-05219,113 Products Professional Engineer Product Model. Number or Name Product Description 1 - &quotFlat Top Off Ridge Vent with Baffle for Tile&quot, Minimum 28 Gauge Steel, Nominal 4&#39;, 6&#39;, 8&#39;, or 10&#39, Wide Off Ridge Vent Attached to Wood Dock 2 2. &quot; Round Top Off Ridge Vent with Baffle for Minimum 28 Gauge Steel, Nominal 4&#39;, 8WQ;, Tile&quot 8&#39;, or 10&#39,, Wide Off Ridge Vent Attached to Wood Deck 3 3- &quotStandard Off Ridge Vent with Permanent Baffle Minimum 26 Gauge Steel, Nominal 4&#39;, 8&#39, for Shingles&quot; 8&#39;, or 10&#39; Wide Off Ridge Vent Attsched'� Wood Dock FLOISM-1111 2292 Versio Manufacturer Affirmation 2014 O'Hagin Manufacturing, LLC Category: Roofing SubCategory: Roofing Accessories that are an Integral Part of the Roofing System Compliance Method: Certification Mark or Listing FLX16588-Ri Products §Pkf Product Model. Number or Name 1 0&#39; Hagin&#3" Cloaked Vent Tile FL#15089-Ri 220 lyn A= Manufacturer Revision 2014 Global Protection Products, LLC. Category. Shutters Subcategory: Fabric Storm Panel Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer FL#1500MI Products Aill" 1. Num bar or Nam 2 1 GPP FABRIC SHUTTER -SERIES 2000 FL#1999-R5 9011 I= Yj= Manufacture Revision 2014 ITW Building Components Group Inc. / Paslode Category: Structural Components Subcategory: Truss Plates Compliance Method: Evaluation Repoit from a Product Evaluation Err* F6M 91&R5 Products 1049 # Pro —duct Model. Number or Name 1 ITW BCG Higher Strength (H &amp; S) 2 ITW BCG Hinge Plate 3 ITW BCG Truiox 4 ITW BCG Wave Validated By Steven M. Urich, PE (717) 317-8454 Page 1 of 1 1/9=17 20 Date Pending 20 Validated Submitted FBC Approval 82U2111119 Status 05101=15 04/29/2015 05/10/2015 06f23/2015 Approved Quality Assurance Apiproved for Use Approved for Use Impact 22= Contract Expiration Date In HVKZ Outside HVHZ Resistant Pressure 12131/2019 No Yes No N/A 12/31/2019 No Yes No N/A 12/31/2019 No Yes No N/A Florida Department of Business & Professional Regulation Building Codes and Standards Product Approval Application Detail Page 1 of I V10/2017 Entity or 20 20 Date Pending 219 Contact Eno Ineer &License Validated 13V Validated Submitted FBC Approval Approved 211111111111 Gregory Daniels Miami -Dade BCCO - CER Ted Berman, PE 06/17/2015 0V1 7/2015 0&25/2015 Approved (707) 872-3020 (305) 8e"707 gdanialsoohagin.com Quality Assurance Approved for Use Approved for Use Im Pact Design Product Description Contract Expiration Date In HVHZ Outside HVKZ Realgart Pressure Attic Ventilation Product for tile roofing applications 04/04/2018 Yes Yes N/A N/A Florida Department of Business & Professional Regulation Building Codes and Standards Product Approval Application Detail Page I of 1 1/902017 Entity or 20 21111111111 Date Pending 20 Contact Enalneer & License Validated By Validated %&M= FBC Approval Approved Status Tim Robinson Walter A. Tilift Jr., P.E. John W. Knezevich, PE 04/27/2015 04r2412015 05/03/2015 0&=15 Approved (VA) 889-7645 PE-44167 (954) 772-6224 tim.robinson@gpPentcom Quality Assurance Approved for Use Approved for Use Impact 22WO Product Describlion Contract Excitation Date In HVHZ Outside HVHZ Resistant Pressure Coated Polyethylene Fabric Panels retained by tracks 12131/2017 No Yes Yes N/A or direct mounted to provide hurricane protection. Florida Department of Business & Professional Regulation Page 1 of I Building Codes and Standards 1/9QO17 Product Approval Application Detail Entity 20 20 Date Pending Mili Contact Engineer & License Validated By Validated Submitted FBC Approval Approved Status Stuart Lewis ICC Evaluation Service, LLC William M. Ranieri, PE 03/25QO15 OW2012015 03129/2015 Approved (847) 918-6473 (407) 881-1917 slovAs@alpineitw.com QualKyAssurance Approved for Use Approved for Use Impact Desilan Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure Metal Connector Plate 12/3112020 Yes Yes N/A N/A Metal Connector Plate l2f3l/2020 Yes Yes N/A NIA Metal Connector Plate 12131/2020 Yes Yes N/A N/A Metal Connector Plate 12131/2020 Yes Yes NIA N/A CU CO 0'0-0 -= 2 a. -2 a 0 a) 31: CU C= 0 .0 .6.0 LL #.- 0 CU > M W -0 0 Cn E CU ca. 1­ CU .6 .10- a -F-0 Cn < Z Z W mi C: 0 0 < _#__0 C/) (D U) 0 ICU 0 CL CL 0 CIO -00 -6--# L_ C/) 13L. CD 0) ICU M CL ICU LU < CL) Z __j SHEET NO. PA 1.2 ILLJa, _N19L, - - - , 1. - - —Cu 0 D > ED 2 L_ (ca:) - 2 CS CU CL Florida Department of Business & Professional Regulation Page 1 of i Florida Department of Business Professional Regulation Page 1 or 1 '75 (D -L-- Building Codes and Standards 1/K017 Building Codes and Standards 1/9/2017 Florida Department of Business & Professional Regulation Page 1 of 1 C = CU -cu Building Codes and Standards 1/9t2017 (D -0 0 -0 Product Approval Application Detail Product Approval Application Detail = 2 -2 -c Product Approval Application Detail 0 5_ C -2 FLA2119741ill FL61 644-R4 LL 2292 Entity or 20 20 Date Pending 20 2992 Entity or 20 20 Date Pandina 20 FLXI$4"4 C .0 0 -6-4 ,— co I= Venslo Manufacturer Contact Engineer & License Validated By Validated Su bm Itted FBC Approval Approved Status I= yj= ManufactiLrer Contact Enalneer & License Validated By Validated Submitted Ezg_AQRMXW Approved own Qft Entity or 20 20 Date Pandina 2mg -0 0 > Revision 2014 MiTak Industries, Inc, David Wart ICC Evaluation Service, LLC ICC Evaluation Service, 08/30/2015 06/11/2015 07/05/2015 Approved Revision 2014 Boise Engineered Wood Products Robert Taylor )CC Evaluation Service, LLC APA - The Engineered 05/27/2015 05/06=15 O&OZ12015 Approved Verslo Manufacture Contact Enalneer & License Y111191112ILM Validated Submitted FEC Aporoval Approved man -Ln E L_ 2 Categorf. Structural Components (314) 851-7480 LLC. Category: Structural Components (541) 828-0200 Wood Association Revision 2014 Boise Engineered Wood Products Robert Taylor ICC Evaluation Service, LLC APA - The Engineered 05127/2015 05/0&M15 06/0212015 Approved S? 0- SubCategory: Truss Plates dvmrt@mii.com (205) 599-98DO Subcategory: Engineered Lumber roberftaylorabc.00m (253) 820-7407 Category: Structural Components (541) 826-0200 Wood Association cc CL Compliance Method: Evaluation Report from a Compliance Method: Evaluation Report from a Subcategory: Engineered Lumber roberdaylorabc.com (253) 620-7467 CU Product Evaluation Entity Product Evaluation Entity Compliance Method: Evaluation Report from a < FL#2197-R5 Products FLX1 644-R4 Products Product Evaluation Entity Quality Assurance Approved for Use Approved for Use Impact Deslan Quality Assurance Approved for Use Approved for Use Im pact Design FL#1645-R4 Products seq 0 Product Model, Number or Name Product DescirlotIon Contract expiration Date in HVHZ Outside HVHZ Resistant Pressure Seq # Product Model, Number or Name Product Description Contract Expimtlon Date in KVHZ Outside HVHZ Resistant Pressure Quality Assurance Approved for Use Approved for Use Impact Design 1 M1 8SHS 18 ga. super high strength truss connector plate 12131/2017 Yes yes N/A N/A 1 Verse -Lam Laminated Veneer Lumber 0110ir2m No Yes N/A NfA §29.1 Product Model, Number gr Name Product Descriotion Contract Expiration Date In HVHZ Outside HVHZ Resistant -Pressure 2 Mil 18 16 ga. truss connector plate 12131/2017 Yes Yes N/A N/A 1 AJS Joists Wood &quat;l&quot; Joists 01/01/2035 No Yes N/A N/A 3 MT18HS 18 ga. high strength truss connector plate 12/31/2017 Yes Yes N/A N/A 4 MT20 20 ga. truss connector plate 12/3112017 yes Yes N/A NIA 5 MT20HS 20 ga. high strength trues oonnectrir plate 12/3112017 Yes Yes N/A NIA Search Criteria Florida Department of Business Professional Regulation Page 1 of I Building Codes and Standards 1WO17 Product Approval Application Detail Florida Department of Business & Professional Regulation Pogo 1 of I Building Codes and Standards VW017 FL00527-Itf Florida Department of Business Professional Regulation Page I of 1 2M Entity or 20 21111111 Date Pending 20 Product Approval Application Detail I= versio Manufacture 220= Snalneer & License Validated By Validated Submitted FBCApproval Approved Building Codes and Standards 1/9f2017 Revision 2014 Weyerhaeuser Jim Anderson ICC Evaluation Service, LLC James A. Rothman, P. E. 07/013/2015 05/1212015 07/3012015 Approved FLMMR? W Category: Structural Components (253) 924-4084 (608) 839-1344 Product Approval Application Detail Subcategory: Engineered Lumber jim.anderson2@vveyerhae 220 Entity or 20 20 2111111111121110= 20 Compliance Method: Evaluation Report from a user.com Versla Manufacture Contact Engineer & License Validated By Validated Submitted FBC Approval Appnoved Product Evaluation Entity Revision 2014 CAST-CRETE USA, Inc. Craig Perrino Miami -Dade BCCO - CER Miami-DodaBCCO-VAL 03/1&2015 02124/2015 03118/2015 Approved FL#1 630-RD FL#6527416 Produm Category: Structural Components (813) 621-4641 (786) 315-2590 Qft Efft1tv or Date Pandina 20 Subcategory. Products Introduced as a Result of cparrinoQcastcrebe.com Versio Manufacturer Contact Enalneer & License Validated By Validated Submitted F5C Alooroval Approved am Quality AssuLInce Approved for Use Approved for Use Impact Design New'rechnology Revision 2014 Weyerhaeuser Jim Anderson ICC Evaluation Service, LLC James A. Rothman, P. E. 07A)SM15 05112/2015 07r3012015 Approved 211" Product Model. Number or Name Product Descriotion Contract Expiration Q0 In HVIHIZ Outside HVHZ agillilli= Pressure Compliance Method: Certification Mark or Listing Category. Structural Components (253) 924-4084 (808) 839-1344 1 iL@vel Rim Board Structural Composite Lumber or Oriented Strand 036112017 No yes N/A N/A FL01158­R7 Products Subcategory,. Engineered Lumber jimanderson2@wayerhae 2 Microliam LVL board Rim Board Laminated Veneer Lumber 03r3l/2017 No yes N/A N/A Quality Assurance Approved for Use Approved for Use IMDaCt Design Compliance Method: Evaluation Report from a user.com 3 Parallam PSL Parallel Strand Lumber 03/31/2017 No Yes NIA N/A S-0 Product Model, Number gr Nam Product Ducription Contract Expiration Date in KVKZ outside HVHZ Resistan Pressure FLX163MO Product Evaluation Entity Products 4 TimberStrand LSL Laminated Strand Lumber 03/31/2017 No Yes N/A N/A 1 Fflgh Strength Concrete Lintels 4, e, 8, and 12 inch Wide lintels 05121/2016 Yes Yes NIA NIA 2121 Product Model, Number or Name Quality Assurance Product Description Contract Expiration Date Approved for Use Approved In HVKZ for Use Outside KVKZ Impa Resistant Design Pressure FL*6527-R7 9012 Entity o 20 20 Date Pend Inc 2& FL*1 58-RO 290 Entity or 20 20 Date Pending Date I TJ: 1110 Prefabricated Wood I -joist 03/31/2017 No yes N/A N/A Verslo Manufacture Contact Enalnear & License Validated By Validated Submitted FBC Aporaval Approved statu I= yg= Manufacturer Contact Enalneer & License Validated By Validated Submitted FBC Approval Approved Status 2 TJ 2 0 Prefabricated Wood I -joist 03/31f2017 No Yes N/A N/A Revision 2014 Weyerhaeuser Jim Anderson ICC Evaluation Service, LLC James A. Rothman, P, E. 10/31120le 10/25/2018 11/05/2016 Approved Revision 2014 CAST-CRETE USA, Inc. Craig Perrino Miami -Dade BCCO - CER Miami -Dade BCCO - VAL 05/06/2016 04129/2016 05/06/2016 Approved 3 4 TJ1230 TJ1360 Prefabricated Wood I -joist 03/31/2017 Prefabricated Wood I -joist 03/31/2017 No No Yes Yes NIA N/A NIA N/A Category; Structural Components (253) 924-4084 (608) 839-1344 Category: Structural Components (813) 621-4641 (786) 315-2590 5 TJ1560 Prefabricated Wood I -joist 03/31/2017 No Yes N/A N/A SubCatagory: Engineered Lumber jim.andemon2oweyerhoe SubCatagory. Products Introduced as a Result of cparrino@castcrete.com 6 TJI/560D Prefabricated Wood I -joist 03/31/2017 No Yes N/A N/A Compliance Method: Evaluation Report from a user.com NewTechnology PLA527-RT Products Product Evaluation Entity Compliance Method: Certification Mark or Listing §291 Product Model, Number or Name Quality Assurance Product Description Contract Expiration Approved for Use Approved for Ussi Date in HVHZ Outside HVHZ Impact Resistant Design PAyssure 2119 Productilill al.NumberorName 2WWWARIUMM Product Descriabon Mon Date ApDr0yed for Use ADDIrOved for Use in HVKZ Outside HVhZ fthDaCt Resistant Design Pressure 1 Microllam LVI_ Laminated Veneer Lumber 03131 r2017 No Yes N/A N/A I High Strength Concrete Lintels 4, 6, 8, and 12 inch wide lintels, 050/2017 Yes Yes N/A N/A 2 Parallam PSL Parallel Strand Lumber 03/31/2017 No yes N/A N/A 3 TimberStrand LSL Laminated Strand Lumber 03/31/2017 No Yes N/A N/A 4 TJ Rim Board Structural Composite Lumber or Oriented Strand 03/31/2017 No Yes N/A N/A board Rim Board 5 Weyerhaeuser Rim Board Oriented Strand Board Rim Board 03131/2017 No Yes N/A N/A Florida Department of Business & Professional Regulation Page 1 of 1 Florida Department of Business Professional Regulation page I of 1 Building Codes and Standards 1/9Q017 Florida Department of Business & Professional Regulation Page 1 of 1 Building Codes and Standards VW017 Product Approval Application Detail Building Codes and Standards 11WO17 Product Approval Application Detail FL#5450-R5 Product Approval Application Detail FL#j 2R92 Entity or 20 21111111 Date Pending 20 FLX11383-R4 I= yj= Manufacturer Contact Enolneer & License Validated Ely Validated Submitted FBC Approval Approved mom 2992 Entity or 20 20 Date Pendina 20 Revision 2014 Powers Steel Inc. William powers Steven W. Schaub SAMUEL A. 03126/2015 03/2312015 03/3012015 06/23=15 Approved 220 I= YIMLq Manufacturer Entity or Contact Enalneer & License Validated By 20 20 Date Pend Ina Validated Submitted F13C Approval Approved Versio Revision 2014 Manufacture Commercial Concrete Products,lric. Contact Enainear & License Validated By Robert Gillis THUYH.HUYNH Florida Engineering Validated Submitted 07/03/2016 06/2412015 FBC Approval 08/20t2015 Approved 0812SQ015 201 Approved Category. Structural Components Subcategory: Products Introduced as a Result of (602) 437-1160 PE-60609 GREENBERG, P.E, bilapowerasteel.com (813) 645-0168 Revision 2014 Powers Steel Inc. William powers Steven Schaub SAMUEL A. 03/2&2015 0312312015 03/30/2015 06/220015 Approved Category. Structural Components (813) 859-3707 PE-801 22 Solutions NewTechnology Category- Structural Components (602) 437-1180 PE-W509 GREENBERG, P.E, SubCategory: Products Introduced as a Result of precastgatorloyahoo.com (352) 5WS311 Compliance Method: Evaluation Report from a Subcategory: Products Introduced as a Result of bill0powerssteel.00m (813) 645,0168 NewTechnology Florida Registered Architect or a Licensed Florida Now Technology Compliance Method: Evaluation Report from a Professional Engineer Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensaid Florida Florida Registered Architect or a Licensed Florida FL#5450-R5 Products Professional Engineer Professional Engineer =L21774-R4 Products I ad" Product Model, Number or Name Quality Assurance Product Dewription Approved for Use Approved for Use InHVHZ Outside HVKZ Im pact Resistant Deslan Pressure FL#1 1383-R4 Products Quail Assurance date Aporoved for Use Approved In for Use Impact 22111122 Pressure 1 PSbox8LT, PSbox&T(5-518) Powers Steel lintels are field assembled lintels 01/27/2017 No Yes NIA N/A 111111121 Product Model. Number or Name 2UML&MUMM Product Descriodon Contract Expiration Date Approved for Use Aporoved for Use In HVIHIZ Outside HVHZ Impact Resistant Deslan Pressure < 11W 1 Product Model, Number or Name Quality Precast or Commercial Concrete Products Product Description Contract Expiration Precast and Prestressed Concrete Lintels O5t25=24 HVKZ No Outside HVKZ Yes Resistant N/A N/A oonsisfing of preformed steel lintels combined with concrete masonry units, grout, and steel reinforcing 1 PowerBOX8 Lintels Powers Steel Lintels are field assembled consisting 01/01/2017 No Yes N/A NIA bars. of preformed steel lintels combined with bdck or concrete masonry units, grout, and steel reinforcing -6-0 (D bars. cn U) 0 ICU 0 L 0- 0_ Florida Department of Business & Professional Regulation ftge 1 of I Building Codes and Standards atl 6/2017 —00 Product Approval Application Detail FL#520$-R2$ 2292 Entity or 20 292 Date Pardino 20 cn I= Version Manufacturer Contact Enolneer & License Validated By Validated submitted FBC Approval AoDfayod Revision 2014 POLYGLASS USA James Akins Robert Niaminen John W. Knezevich, PE 03/22/2017 03113/2017 03/22/2017 06/1312017 Approved Category: Roofing (570) 384-1230 PE-591M (954) 772-M4 Subcategory: Underlayment jakinsCpolygiess.com ICU Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida FL#52t9-R3 Professional Engineer Products Quality Assurance Approved for Use Approved for Use [in oact Design Product Model rorNaml Product Description Contract Expiration Date In HVKZ Outside HVHZ Resistan Pressure 1 Polyglass Roof Underlayrnents Roofing undertalyments 0412412018 No Yes N/A +N/A/-622.5 ICU Uj Search Criteria Code Version: 2014 FLO ALL < (D Application Type: ALL Product Manufacturer. POLYGLASS USA Category: Roofing Subcategory: Underlayments Application Status: ALL Compliance Method: Evaluation Report fro a Florida Registered Architect or a Licensed Florida Professional Engineer z Quality Assurance Entity Contract Expired: ALL Product Model, Number or Name: ALL < Product Description: ALL Approved for use In HVHZ: yes Approved for use outside HVHZ: No Impact Resistant ALL _j Design Pressure: ALL Date From: ALL CL Date To: ALL SHEET NO. PA 1 .3- q 2,43 S y �I7r��g