Loading...
HomeMy WebLinkAbout36071 Carriage Pine CtABBREVIATIONS A.B. Anchor Bolt F. P. Fireplace P.T. Pressure Treated Abv. Above F.O.M. Face Of Masonry Pwd. PowderRoom A/C Air -Conditioner Ft. Foot/ Feet Red. Radius ADJ. Adjustable Ftg. Footing Ref. Refrigerator A. F. F. Above Finished Floor FIX Fixed Req'd. Required A.H.U. Air Handler Unit ALT. Alternate GaIv. Galvanized Rm. Room B.A. Base Cabinet G.C. General Contractor Rnd. Round BF Bifold Door G. F. 1. Ground Fault Interrupter R/S Rod and Shelf BkSh BookShelf G.T. Girder Truss SD. Smoke Detector Bm. Beam Hdr. Header S.F. Square Ft. Bot. Bottom Hgt. Height Sh. Shelves B.P. Bypass door HB Hose Bibb SHT Sheet BRG. Bearing Int. Interior S1. Side Lights Cir. CIg. Circle Ceiling K/Wall Kneewall S. P. F. Spruce Pine Fir Ci Control Joint K.S. Knee Space Sq. Square Col. Column Laun. Laundry S.Y.P. Southern Yellow Pine Comm. Community Lev. Lavatory TB TowelBar Comp. Compressor L. F. Linear Ft. Temp. Tempered C.T. Ceramic Tile LL Lintel Length Thik'n. Thicken D. Dryer LT. Laundry Tub T.O.B. Top of Block DB Door Bell Mas. Masonry T.O.M. Top of Masonry Dec. Decorative T. 0. P. Top of Plate Ded. Dedicated Outlet Max Maximum TR TOWEL RING Dbl. Double M.C. Medicine Cabinet Dia. Diameter Mfgr. Manufacturer TP TOILET PAPER Disp. Disposal Micro. Microwave Trans. Transom Wndow Dist. Distance Min Minimum Typ- Typical D.S. Drawer Stack M.L. Microlam U.C. Under Counter D.V. DryerVent Mir. Mirror UCL Under Cabinet Lighting D.W. Dishwasher U.N.O. Unless Noted Otherwise Ea. Each Mono Monolithic V. Shower Valves E.W. Each Way N.T.S. Not to Scale VB Vanity Base Elec. Electrical Opn'g. Opening Vert. Vertical Elev. Elevation opt. Optional V. L. Versalam Ext. Exterior PC. Piece VTR Vent through Roof Exp, Expansion Ped. Pedestal w Washer FBC Florida Building Code PH PHONE W/ With Fin. FIr. Finished Floor P.L. Parallarn W/C Water Closet F.G. ixed Glass PLF Pounds per linear foot W.A. Wedge Anchor FIr. Floor Pit. HI. Plate Height Wd Wood Fdn. Foundation Pit Sh. Plant Shelf WP Water Proof FIr Sys Floor System PSF Pounds per square foot REVISIONS 08-20-15 1.00 NEW BASE PLAN 12-08-15 2.0 FRAME-WAL REVISIONS All WORK SHALL CoMpLy WITH PREVAILING CODES FLORIDA BUILDING CODE, NATIONAL ELECTR ' (Q CODE,-ANJ),i LLP- ORO"t*�NCRs ") I W REVIEW DATE,,:Y, CITY OF ZEPHY-rqH[i ic Im 17= F14 INI *lox 11SM PLAN EXAMINE� %J 2575 INDEX OF DRAWINGS SHEET DESCRIPTION SHEET No. CS COVER SHEET 1 MAIN FLOOR PLAN 1.1 UPPER FLOOR PLAN 2 INTERIOR ELEVATIONS 3.1 EXTERIOR ELEVATIONS 3.2 EXTERIOR ELEVATIONS F1 FOAM DETAIL 4 MAIN ELECTRICAL PLAN 4.1 UPPER ELECTRICAL PLAN 5 ROOF PLAN 6 FOUNDATION PLAN 7 MAIN FRAMING PLAN 7.1 ROOF FRAMING PLAN 8 LINTEL DETAILS SN STRUCTURALNOTES SN1 DETAILS S3 STEM DETAILS S4 DETAILS S5 DETAILS SIS DETAILS ST —STAIR DETAILS SS RETROFIT DETAILS D1 SECTIONS & DETAILS WP WATERPROOFING DETAILS PA1.0 PRODUCTAPPROVALNUMBERS PA1.1 PRODUCTAPPROVALNUMBERS PA1.2 PRODUCTAPPROVALNUMBERS PA1.3 PRODUCTAPPROVAL NUMBERS MEAN ROOF 15 FT. HIGH TYPICAL / A r— 3 FOR SINGLE STORY HOMES AP efi fri MEAN ROOF 30 FT. HIGH TYPICAL FOR 2 STORY HOMES THIS DRAWING AND DESIGN IS VALID FOR 12 MONTHS AFTER THE DATE IT IS SIGNED AND SEALED OR WHILE CURRENT CODE IS VALID Notice to Builder & All Subcontractors It is the intent of Designer/Engineer listed in the titleblock of these documents that these documents be accurate, providing Licensed Professionals clear information. Every attempt has been made to prevent error. The Builder and all subcontractors are required to review all the information contained in these documents, prior to the commencement of any work. The Designer/Engineer are not responsible for any plan errors, omissions,or misinterpretations undetected and not reported to the Designer / Engineer prior to construction. All construction MUST be in accordance to the information found in these documents. Any questions regarding the information found in these plans should be directed to our Office at (407) 880-2333 immediately. No backcharges will be considered for reimbursement by the Designer/Engineer without advanced notification and approval by the Designer/Engineer, Payments will be made in accordance to the terms of the agreement. Lou Z Z Z CL C Z 0 C—/) ID(O 4-J LU Q U 0 LU E Ul) YZ2 0 Cl) 00 LU E 8 cm ce) c m Cl) 2:2 CC*114 0.2 C, -r ai ZU-2 5,6- 05 CL < 0 U) 0 C; A I D. 11. 11 11 D. 1— co "i 6 e. Z Z < Z Lz LU or- I0 El Cl To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code Sth Edition (2014) Residential. Engineer's signature and seal Is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. 0 0 Z N 0(1) 0-4 4-J C) U') '- I'D CD > U-) M Ln CL (n 72 V" IN V) 0) 0 Ln C U- F- C>L al� U Z CL 00 < . E Z Z LU W Milli 0, Z g U, Z H �l Z, W- LLJ E�ZLU LU Lr) C/) 8 Z 0 -0 N Cr— M Lr) LU > 0 ZO bo < a LU 2: 9 Z Z UJI C"4 rNI Ln U_gi� jg� Lij Lij X E-L, 8 � 0 0 C%4 < < Z T-1 Z Z t-u 1Z 0 1 N :5 LLJ 9 rn T-4 1 0. (n A SCALE AS NOTED DATE 2/24/2014 TECH: FFLORES VERSION No. 10 SHEET NO. CS 9 TYP @ 2 STORY H.B.T (3) 2X4 #2 SPF W/ (3) 16d TOENAILS @ BASE �COND. �COND. (PG S 3 i jUP j16R TYP @ 2 STORY 9 3 14 15 h 7.1 50 - - - - - - - FLOOR G.T. I I I I 9 +42" SLOPING 1 HALF WALL 00 co FAMILY ROOM (3) IX4 #2 SPF -- T.B�- 12 'Zo A W/ (3)16d Cl) 8'-8" FLAT CLG. '? F, TOENAILS @ CARPET BASE FLEX 0 8'-8" FLAT CLG. d I Cn 0 CO (D CARPET 8� 00 C14 -4- u_ (2) #5'S - JL ZXb WALL 5- H 12" DEEP //- L? A. 2068 B.F. - - - - - - - - - - -- - - - - - - - - - - -- DR AT 7'-4" - - - - - - --- 8'-8" FLAT C.L.G. T-8" T-8" 3'-6" 6-0" TRY 61 -1 FOYER___�__ TYP @ 2 STORY Ir 111 01 0 �j LO �l 1 8'-8" FLAT CLG. 3068 (2) #5'S (3) 2X4 #2 SPF W/ j u_ U-1 TILE I - - - - - - (3) 16d TOENAILS @ BASE (3) Z' K4 #2 SPF W/ Z? \ZZ(3 2X4 #2 SPF W/ ) n TCC--., cc (3) 16d TOENAILS 3) 16d TOENAILS @ BASE LO 0 BASE @ - - - - - - - - - - - - 0 2'-6" BUILDER TO PROVIDE 6- D S3 CD 00 .0 APPLIANCE PROTECTION (D '0 DINING ROOM WHEN REQUIRED PER FBC I PATIO 8'-8" FLAT CLG. CARPET 2 CAR GARAGE 8'-8" FLAT CLG. 6-2" 6-6" 4'-8" 20'-8" EDGE OF SLAB 2" 0 L BEYOND WALL C14 9 IT - - - - - - - L - - - - - - - - CIJ 3. 38 cc cc _j Ui > 0 KITCHEN 7 X CY) CN 8'-8" FI_AT CLG. TILE H1 21368 9 19 60 2666 B-.F -_ 1, /_ 2x6 WALL REF. 24 24 OPT. 1 PA�TR Y� L U L - - - - - 16" DEEP rD \,, - - - - - - - - - - - - 5 -SH �3 J 1 CN .- j � 1770 1 1 1 1 1 111111 -1 1 1 lip I I I I I I I I I 110 11111111 )TYP @ 2 STORY H.B.� HEADER SCHEDULE MARK HEADER SIZE REMARKS (2) - 2X6 #2 SYP W/ 1/2" FLITCH PLATE (2) - 2X8 #2 SYP W/ 1/2" FLITCH PLATE <@>(2) - 2X1 0 #2 SYP W/ 1/2" FLITCH PLATE (2) - 2X1 2 #2 SYP W/ 1/2" FLITCH PLATE (2) - 1 3/4" X 11 1/4 LVL 2.OE Fb=2950 <@>(2) - 1 3/4" X 9 1/4" LVL 2.OE Fb=2950 <e>(2) - 13/4" X 16" LVL 2.OE Fb=2950 (2) - 13/4- X 7 1/4" LVL 2.OE Fb=2950 (2) - 2X4 #2 SYP W/ 1/2" Follow Q/S4. See Plan for R.A.G. FLITCH PLATE Bearing Wall Call Out When Straps are Required *VERIFY W/ PLAN CORRECT LENGTH OF HEADER REQUIRED SEE PLAN FOR DETAIL CALL OUT FOR CONNECTIONS AND REQUIRED STUDS WINDOW SCHEDULE SIZE R.O. CMU (Flange) R.O. FRAME (Fin) TYPE 12 20 X 26 18JX254 S.H. 13 20 X 38 j 184X371 S.H. 14 20 X 501 184X 50 S.H. 15 20 X 63 18JX62j S.H, 16 20 X 72 18 j X 71 j S.H. j 32 27 1/4 X 26 26 X 25 S.H. 133 27 1/4 X 38 j N/A S.H. 134 27JX50i N/A S.H. 433 NIA 26 x 37 S.H. 434 N/A 26 x 50 S.H. 435 27 j X 63 26 X 62 1/2 S.H. J36 27 j X 72 26 X 71 1/2 S.H. 22 37JX26 364X25 1/2 SM. 23 37 j X 38 j 36 j X 37 3/4 S.H. 24 37 j X 50 j 36 j X 50 S.H. 25 37JX63 36 4 X 62 1/2 S.H. 26 37 j X 72 36 j X 71 1/2 S.H. DOUBLE 2 WIDE 75" TALL 734WIDE S.H. 32 54 X 26 52 4 X 25 S.H. 33 54 X 38 j 52 j X 37 1 S.H. 34 54 X 501 52 j X 50 S.H. 35 54 X 63 52 j X 62 j S.H. 36 54 X 72 52 4 X 71 S.H. 39X59 40 X 59 N/A S.H. DOUBLE 39X59 79 X 59 N/A S.H. General notes R302.5 Dwelling/Garage Open I ng/Penetration Protection. • Openings from a private garage directly into a room used for sleeping purposes shall not be permitted. Door between garage and residence shall be equipped with solid doors not less than 13/8" in thickness, solid or honeycomb -core steel doors not less than 1 3/8" thick, or 20-minute fire -rated doors, equipped with self-closina device. • Duct Penetration. Ducts in the garage and ducts penetrating the walls or ceilings separating the dwelling from the garage shall be constructed of a minimum No. 26 gage (0.48 mm) sheet steel, 1 inch minimum rigid nonmetallic class 0 or classl duct board, or other approved material and shall have no openings into the garage. • Other penetrations shall be protected as required by section R302.1 1, Item 4. R302.6 Dwelling/Garage Fire Separation. The garage shall be separated from the dwelling as per the following: • From the Residence & Attics - Not Less than 1/2" Gyp. Bd. or equivalent applied to garage side. • From Habitable Rooms Above Garage - Not Less than 5/8" Type-X Gyp. Bd. or equivalent. • Structure(s) Supporting Floor/Ceiling Assemblies - Not Less than 1/2" Gyp. Bd. or equivalent. • Garages Located Less Than 3 Feet From Dwelling On The Same Lot - Not Less than 1/2" Gyp. Bd. or equivalent applied to the interior side of exterior walls that are within this area. R312.2.1 Window Sills. in dwelling units, where the opening of an operable window is located more than 72 inches above the finished grade or surface below, the lowest part of the clear opening of the window shall be a minimum of 24 inches above the finished floor of the room in which the window is located.Operable sections of windows shall not permit openings that allow a 4-inch-diameter sphere where such openings are located within 24 inches of the finished floor. Chapter 45 Private Swiming Pools, Section R4501.17.1.9 All doors and windows providing direct access from the home to the pool shall be equipped with an exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 db a at 10 feet. Any deactivation switch shall be located at least 54 inches above the threshold of the access. Separate alarms are not required for each door or window if sensors wired to a central alarm sound when contact is broken at any opening. M 1507.2 Recirculation of Air. Exhaust air form Bathrooms and toilet rooms shall not be recirculated within a residence or to another dwelling unit and shall be exhausted directly to the outdoors. Exhaust air from bathrooms and toilet rooms shall not discharge into an attic , crawl space or other areas inside the building. GAS APPLIANCES G.C. to verify location of gas riser before commencement of work. see Sht. SN1 for installation detail. Where gas water heaters are installed. Water heaters shall be installed a min. of 18" above fIr. per FBCR G2408.2. Except where appliances that are listed as flammable vapor ignition resistant. OPENING PRESSURES ENCLOSED - EXPOSURE "C" +25.6 -27.8 +25.6 / -34.3 +24.5 -26.7 +24.5 / -31.9 +23.0 -25.2 +23.0 / -28.9 SEE SN SHEET SEE SN SHEET 'T 140 MP�H NOTE: WIND SPEED INDICATED ABOVE IS AN "ULTIMATE" WIND SPEED. THE WIND PRESSURES LISTED ABOVE ARE ALLOWABLE PRESSURES WALL LEGEND TYP. 2x FRAME WALL BEARING WALL INTERIOR BEARING WALLS NOTED "FLOOR BEARING ONLY" ARE FLOOR SYSTEM SUPPORTING ONLY AND REQUIRES NO UPLIFT CONNECTORS TO FLOOR SYSTEM AREA TABULATION "All 1ST FLOOR LIVING AREA 1093 2ND FLOOR LIVING AREA 1491 LIVING TOTAL 2584 GARAGE 427 FRONT ENTRY 35 TOTALAREA 3046 0 INSULATION REQ. LOCATION R-VALUE / TYPE EXT CONC WALL R-4.1 HIGH PERM EXT FRAME 2 x 4 R- 11 /R- 13 KRAFT FA51ID EXT FRAME 2 x 6 R-19 KRAFT FACED CONDITIONED CEILING R-30 BLOWN -IN (INSTALL BAFFELS AT EAVE) GARAGE SEPARATION (GARAGE / LIVING) R-11/R-13 KRAFTFACED I 0 LO z ce) -8 z (0 __j CZ1 - z 4--J Lu C) U 0 LU II V) 0 � �2 Co LU E 8 0) Cl) ce) w n "'a CN 0.9 C, LL 02 W C, C, < 0 6 A I RD N" 1�- C� i� AL ff.45 S.- C, J1 cj 4). . LL U3 L z FES$ L LU cv, M 7 [30 To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code Sth Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. 0 0 Z r4 0 Cu r, �-4 4.j C) V) tD M C:) p Cn M Ln CJ- Lf) z in L_ LL cl� U 00 z < z § E Z fu LU CD _j 0 W ko z P- 21 LU z Z, z z Ln 0 z :D 0 -0 M N Ln 0 _j LL 2: z L_ > 0 U -.- V) II Lu �.j r-4 U4 ar:� * j � r*4 a wi Z z LU r44 Lr) LU ug�� §Ei fle _j LU z z z z 0 r� z <� LU 9 SCALE AS NOTED DATE 2/24/2014 TECH: FLORES VERSION NO' 10 SHEET NO. 0 D2 OWNER'S SUITE 8'0" FLAT CLI T-8j" 1 _j S6 TYP @ 2 STORY Eli J 31 4 1 5 1 6 1 71.8 WMI Mwo,"'Am -1 a. MLIJ WIA Lo. 00 LAW 41'. F; CLG Lo U Al �Lo &to, CIL 0 0 5- 10'. Fd FIBERGLX $ SURROUN) R&S 60"X36" MW CIO LU z W Lu Cc SHOWER ... .0 z CD 41- CD 4" 11 LL 00 co ATTIC L&oen�s' OP &D ;t b r�w 51 X" TYP @ 2 STORY d u_ 0 0 LOFT 8'-0" FLAT CLG. CARPET � 1. - BEDROOM 2 8'-0" FLAT CLG. CARPET 1IT-745" Lu L----------- 4068 B.F. ffFM 1 I r j �6 TYP @ 2 STC T-1 c' RY 4068 B.F. 6-5�" T 2'-4" 13'-0" - '0 04 4,-21� 4'-22 - 0 _'G a Q 5�ql 1 V-81" U)l 05 08 ROOF G.T. B T c? Lu cc sui cc 0-- F 8' .0" FLAT,, C L 0 W. I. C. 1 BEDROOM 3 BEDROOM 4 - �P __ __ - 8'-0" FLAT CLG. 18'-0" FLAT CLC 1 8'-0" FLAT CLG. CARPET TY TYP @ 2 STORY CARPET 9 cc- C L - - - - - G) R&S EGRESS 27SH <�> 4) 1 38-4- 39'-0" El N D2 F, Sim. w/ (5) STUDS i 00 <�>4) TYP @ CORNERS U. N. 0. HEADER SCHEDULE MARK HEADER SIZE REMARKS (2) - 2X6 #2 SYP W/ 1/2" FLITCH PLATE (2) - 2X8 #2 SYP W/ 1/2" FLITCH PLATE (2) - 2X10 #2 SYP W/ 1/2' FLITCH PLATE (2) - 2X12 #2 SYP W/ 1/2" FLITCH PLATE (2) - 1 3/4' X 11 1/4 LVL 2.OE Fb=2950 (2) - 13/4" X 9 1/4" LVL 2.OE Fb=2950 (2) - 13/4" X 16" LVL 2.OE Fb=2950 (2) - 1 3/4" X 7 1/4" LVL 2.OE Fb=2950 (2) - 2X4 #2 SYP W/ 1/2" Follow Q/S4. See Plan for R.A.G. FLITCH PLATE Bearing Wall Call Out When Straps are Required VERIFY W/ PLAN CORRECT LENGTH OF HEADER REQUIRED SEE PLAN FOR DETAIL CALL OUT FOR CONNECTIONS AND REQUIRED STUDS ir,111141 EXTERIOR 2ND FLOOR BEARING WALL SCHEDULE HEIGHT STUD SPECIES SPACING SPF #2 8'-0" 2x4 SYP #2 16" O.C. SPF #2 91-011 2x4 SYP #2 16" O.C. SPF #2 >91-01. 2x6 SYP #2 16" O.C. * IF WITHIN 4FT OF END ZONE, USE DOUBLE STUDS AT CORNERS ** WALL SHEATHING 15/32"EXPOSURE 1 OR EQUIVALENT SEE CIS6 WALL SCHEDULE WINDOW SCHEDULE SIZE R.O. CMU (Flange) R.O. FRAME (Fin) TYPE 12 20 X 26 184X254 S.H. 13 20 X 38 18 4 X 37 j S.H. 14 20 X 50 18 4 X 50 S.H. 15 20 X 63 18JX624 S.H. 16 20 X 72 18 j X 714 S.H. 32 27 1/4 X 26 26 X 25 S.H. 433 27 1/4 X 38 N/A S.H. 434 27JX 501 N/A S.H. 433 N/A 26 x 371 S.H. 434 N/A 26 x 50 S.H. 435 27 j X 63 26 X 62 1/2 S.H. 436 27 1 X 72 26 X 71 1/2 S.H. 22 37 j X 26 36JX25 1/2 S.H. 23 37 1 X 38 36 4 X 37 3/4 S.H. 24 37 1 X 50 36 j X 50 S.H. 25 37 1 X 63 36 4 X 62 1/2 S.H. 26 37 j X 72 36 4 X 71 112 S.H. DOUBLE 2 WIDE 75"TALL 73JWIDE S.H. 32 54 X 26 524X25i S.H. 33 54 X 38 j 52 4 X 37 j S.H. 34 54 X 50 j 52JX 50 S.H. 35 54 X 63 52 4 X 62 S.H. 36 54 X 72 52j X 714 S.H. 39X59 40 X 59 N/A S.H. DOUBLE 39X59 79 X 59 N/A S.H. General notes R302.5 Dwelling/Garage Open ing/Penetration Protection. • Openings from a private garage directly into a room used for sleeping purposes shall not be permitted. Door between garage and residence shall be equipped with solid doors not less than 13/8" in thickness, solid or honeycomb -core steel doors not less than 1 3/8" thick, or 20-minute fire -rated doors, equipped with self -closing device. • Duct Penetration. Ducts in the garage and ducts penetrating the walls or ceilings separating the dwelling from the garage shall be constructed of a minimum No. 26 gage (0.48 mm) sheet steel, 1 inch minimum rigid nonmetallic class 0 or classl duct board, or other approved material and shall have no openings into the garage. • Other penetrations shall be protected as required by section R302.1 1, Item 4. R302.6 Dwelling/Garage Fire Separation. The garage shall be separated from the dwelling as per the following: • From the Residence & Attics - Not Less than 1/2" Gyp. Bd. or equivalent applied to garage side. • From Habitable Rooms Above Garage - Not Less than 5/8" Type-X Gyp. Bd. or equivalent. • Structure(s) Supporting Floor/Ceiling Assemblies - Not Less than 1/2" Gyp. Bd. or equivalent. • Garages Located Less Than 3 Feet From Dwelling On The Same Lot - Not Less than 1/2" Gyp. Bd. or equivalent applied to the interior side of exterior walls that are within this area. R312.2.1 Window Sills. In dwelling units, where the opening of an operable window is located more than 72 inches above the finished grade or surface below, the lowest part of the clear opening of the window shall be a minimum of 24 inches above the finished floor of the room in which the window is located.Operable sections of windows shall not permit openings that allow a 4-inch-diameter sphere where such openings are located within 24 inches of the finished floor. Chapter 45 Private Swiming Pools, Section R4501.17.1.9 All doors and windows providing direct access from the home to the pool shall be equipped with an exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 db a at 10 feet. Any deactivation switch shall be located at least 54 inches above the threshold of the access. Separate alarms are not required for each door or window if sensors wired to a central alarm sound when contact is broken at any opening. M 1507.2 Recirculation of Air. Exhaust air form Bathrooms and toilet rooms shall not be recirculated within a residence or to another dwelling unit and shall be exhausted directly to the outdoors. Exhaust air from bathrooms and toilet rooms shall not discharge into an attic, crawl space or other areas inside the building. GAS APPLIANCES G.C. to verify location of gas riser before commencement of work. see Sht. SN1 for installation detail. Where gas water heaters are installed. Water heaters shall be installed a min. of 18" above fir. per FBCR G2408.2. Except where appliances that are listed as flammable vapor ignition resistant. OPENING PRESSURES ENCLOSED - EXPOSURE "C" +25.6 -27.8 +25.6 / -34.3 +24.5 -26.7 D +24.5 / -31.9 +23.0 -25.2 +23.0 / -28.9 SEE SN SHEET SEE SN SHEET MPH NOTE: WIND SPEED INDICATED ABOVE IS AN "ULTIMATE" WIND SPEED. THE WIND PRESSURES LISTED ABOVE ARE ALLOWABLE PRESSURES WALLLEGEND MASONRY HGT. @ 8'-8" A.F.F. TYP. 2x FRAME WALL U I I I 1 17 17 17 17 1 1 BEARING WALL INTERIOR BEARING WALLS NOTED "FLOOR BEARING ONLY" ARE FLOOR SYSTEM SUPPORTING ONLY AND REQUIRES NO UPLIFT CONNECTORS TO FLOOR SYSTEM AREA TABULATION "All 1 ST FLOOR LIVING AREA 2ND FLOOR LIVING AREA LIVING TOTAL GARAGE FRONT ENTRY TOTAL AREA INSULATION REQ. 1093 1491 2584 427 35 3046 0 LOCATION R-VALUE / TYPE EXT CONIC WALL R-4.1 HIGH PERM EXT FRAME 2 x 4 R-1 1 /R-1 3 KRAFT FACED EXT FRAME 2 x 6 R-19 KRAFT FACED CONDITIONED CEILING R-30 BLOWN -IN (INSTALL BAFFELS AT EAVE) GARAGE SEPARATION (GARAGE / LIVING) R-11/R-13 KRAFT FACED (D !;2 0 z M z ZE3Q_ (n Cz Z V) 0 Q) c_/) 4-) Li-i 0 Lu V) Of § C11 0 4) cNe) LU E 8 0) M a MM m -0 cv) 0 = 04 LL 0 CO CL ..Ne < 0 cm Lo 0 'T Al ED. N-C-B�D�C NR N 18 &MR A - x !j __j LE. G�� . *. . .0 04 ILL < up -LU C', IF UM 'r - C'N G-V 41= am Cq P le 11 E 0 �/111 It 0 El To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code Sth Edition (2014) Residential. Engineer's signature and seal Is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. C) C) Z C*4 0 (1) r4'., P-4 C) LO =3 %0 > V) rn CD p 11`0 Ln (Al o Ln C U_ c>L F- C)� U 0-00 z "El Z3: z _j C:) LULU C:) F- z g < kis uj a 2 1j CL U Lr) 0 z z 0 _0 0 (>L) Lr) (`4 UL- 0 U V) C\1 UJ F- 0 < Z 2 z LLI 117�4 Ln < < z LU I-; 0 z Z :5 t LU N2 0 10- U') SCALE AS NOTED DATE 2/24/2014 TECH: FLORES VERSION No. 10 SHEET NO. STANDARD (3) 2x12 STRINGERS w/ SIMPSON A35/USP MP34 CLIP TO FLOOR SYSTEM OR LANDING FRAMING (2) 2x HDR. REQ'D @ END OF LANDING FOR STRINGERS TO CONNECT TO PLY SHEATHING OVER LANDING ATTACHED PER GENERALFLOOR CONSTRUCTION NOTES KITCHEN 2x8 #2 SYP JOISTS @ LANDING @ 16"O.C. wl SIMPSON A35/USP MP34 OR LUS26 HANGER ON EA. SIDE MASONRY OR WOOD WALL, SEE PLAN 2x8 #2 SYP (P.T. IF MANSONRY WALL) CONT LEDGER w/ (3) 16d NAILS @ 16" O.C. MAX. TO EA, STUD. ((2) 1/4"X3 1/2" TITENS @ 16" O.C. MAX. FOR MASONRY WALL) GENERAL LANDING FRAMING INFO. SCALE: N.T.S. 9'-0" MAX LANDING LENGTH PRF-FNG FI-OOR.101,qT W/ (21 ac 8'-!54" A,_n-- BATH 2 KITCHEN ;0 00 STAIR CALCUTIONS: TOTAL RISE = 10'-0 3/4" (16) RISERS AT 7 9/16- 10"TREADS W/ 1"NOSING MIRROR 0 F L co OWNER'S BATH M KITCHEN ISLAND INTERIOR ELEVATIONS SCALE: 1/2"=V-0" The radius of the nosing shall be no greater that V16"- Solid riser nosings shall not be less than %" but not more than %". The greatest nosing projection shall not exceed the smallest by more than Y2". Beveling of nosings shall not exceed MIN. (3) 2x STUDS REQ'D @ END OF LANDING BELOW HDR. BEAM. Stairway construction and handrail to conform to the FBC 5th Residential section R311.7 Riser height: The maximum riser height shall be 7%". The greatest riser height within any flight of stairs shall not exceed the smallest by more than %". Tread depth. The minimum tread depth shall be 10". The greatest tread depth within any flight of stairs shall not exceed the smallest by more than 31/8". 2x8 #2 SYP JOISTS @ LANDING @ 16" O.C. w/ SIMPSON A35 CLIP OR LUS26 HANGER TO LEDGER W 0 2x12 HDR. w/ (3) 2x STUDS AT Z PLYWOOD @ EA. END FOR BEARING LANDING STANDARD (3) 2X12 STRINGERS W/ SIMPSON A35 STANDARD (3) 2' STRINGERS W'� CLIP TO HDR. 11 T x TREADS (TYP.) 2x8 LEDGER #2 SYP w/ (3) 16d NAILS TO STUD CONT. HANDRAIL @ 16" O.C. 10 Handrails. Handrails shall be provided on at least one side of each continuous run of treads or flight with four or more risers. Handrail height, measured vertically from the sloped plane adjoining the tread nosing, or finish surface of ramp slope, shall be not less than 34" and not more than 38". Handrails adjacent to a wall shall have a space of not less than %"between the wall and the handrails. Grip -size. Handrails with a circular cross section shall have an outside diameter of at least 1 1/4" and not greater than 2" or provide equivalent graspavility in compliance with FBC 5th Edition (2014) Residential Section R311.7.8.3. Guards. Guards shall be located along open -sided walking surfaces, including stairs, ramps and landings, that are located more than 30" and shall be not less than 36". Required guards shall not have openings from the walking surface to the required guard height which allow passage of a sphere 4" in diameter. Winders. Winder treads shall have a minimum tread depth of 6" at the narrow end and shall have a minimum tread depth of 10" at the intersections with the walkline (12" from the narrower side). THRUST BLOCK SECURED TO---_� R302.7 Under -Stair Protection. SLAB w/ 1/4"X3 1/2" TAPCONS Enclosed accessible space under a stairway shall be protected with Y2 gyp. bd @ 16" O.C. ^ "V� A I rm% e% r� 0'*% mTm 10`% IL I SCALE: 1/2"=V-0" ( D V0 Z Z Z Z V) (D C—n 4--J Lu D U 0 U.1 UO CLI V) 04 C) 0) M (M C M cl E T .7S cvQ 8 000 c) 0 0 < < 01 N C IS-D-C A FZ' 8 Do 0 Sr W 9 _J le IF"M , a!1 tw ..i P'Ll - >, 0 1<1 .;; Z N I F E SS To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code Sth Edition (2014) Residential. Engineer's signature and sea] is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. C) Z r-4 0 cu r-, 1­4 4-J CD V) 1 5 tD > V) M 0 rn 0 N < V) -0 a. Ln C: Z A U. Q� U CL 00 Z < 3i E Z Z CD W 8 0, Ck: C/) Lu _J 11 ; i < F_ U-1 0 cr- Z '0 0 Ln 2: cc 2: r-4 U-1 0 U 0 r-4 U4 ar:!l < Z r-4 Z C%4 11i Ln _J Lij I UJ X X < f%4 < Z IT Z L co Z LU 0 0 r�- 15 Z: 9 rn T-q Ia. (n SCALE AS NOTED DATE 2/24/2014 TECH: FLORES VERSION NO - 10 SHEET NO. 2.0 � SEE PLAN FOR LANDING DEPTH OWNER'S BATH M KITCHEN ISLAND INTERIOR ELEVATIONS SCALE: 1/2"=V-0" The radius of the nosing shall be no greater that V16"- Solid riser nosings shall not be less than %" but not more than %". The greatest nosing projection shall not exceed the smallest by more than Y2". Beveling of nosings shall not exceed MIN. (3) 2x STUDS REQ'D @ END OF LANDING BELOW HDR. BEAM. Stairway construction and handrail to conform to the FBC 5th Residential section R311.7 Riser height: The maximum riser height shall be 7%". The greatest riser height within any flight of stairs shall not exceed the smallest by more than %". Tread depth. The minimum tread depth shall be 10". The greatest tread depth within any flight of stairs shall not exceed the smallest by more than 31/8". 2x8 #2 SYP JOISTS @ LANDING @ 16" O.C. w/ SIMPSON A35 CLIP OR LUS26 HANGER TO LEDGER W 0 2x12 HDR. w/ (3) 2x STUDS AT Z PLYWOOD @ EA. END FOR BEARING LANDING STANDARD (3) 2X12 STRINGERS W/ SIMPSON A35 STANDARD (3) 2' STRINGERS W'� CLIP TO HDR. 11 T x TREADS (TYP.) 2x8 LEDGER #2 SYP w/ (3) 16d NAILS TO STUD CONT. HANDRAIL @ 16" O.C. 10 Handrails. Handrails shall be provided on at least one side of each continuous run of treads or flight with four or more risers. Handrail height, measured vertically from the sloped plane adjoining the tread nosing, or finish surface of ramp slope, shall be not less than 34" and not more than 38". Handrails adjacent to a wall shall have a space of not less than %"between the wall and the handrails. Grip -size. Handrails with a circular cross section shall have an outside diameter of at least 1 1/4" and not greater than 2" or provide equivalent graspavility in compliance with FBC 5th Edition (2014) Residential Section R311.7.8.3. Guards. Guards shall be located along open -sided walking surfaces, including stairs, ramps and landings, that are located more than 30" and shall be not less than 36". Required guards shall not have openings from the walking surface to the required guard height which allow passage of a sphere 4" in diameter. Winders. Winder treads shall have a minimum tread depth of 6" at the narrow end and shall have a minimum tread depth of 10" at the intersections with the walkline (12" from the narrower side). THRUST BLOCK SECURED TO---_� R302.7 Under -Stair Protection. SLAB w/ 1/4"X3 1/2" TAPCONS Enclosed accessible space under a stairway shall be protected with Y2 gyp. bd @ 16" O.C. ^ "V� A I rm% e% r� 0'*% mTm 10`% IL I SCALE: 1/2"=V-0" ( D V0 Z Z Z Z V) (D C—n 4--J Lu D U 0 U.1 UO CLI V) 04 C) 0) M (M C M cl E T .7S cvQ 8 000 c) 0 0 < < 01 N C IS-D-C A FZ' 8 Do 0 Sr W 9 _J le IF"M , a!1 tw ..i P'Ll - >, 0 1<1 .;; Z N I F E SS To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code Sth Edition (2014) Residential. Engineer's signature and sea] is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. C) Z r-4 0 cu r-, 1­4 4-J CD V) 1 5 tD > V) M 0 rn 0 N < V) -0 a. Ln C: Z A U. Q� U CL 00 Z < 3i E Z Z CD W 8 0, Ck: C/) Lu _J 11 ; i < F_ U-1 0 cr- Z '0 0 Ln 2: cc 2: r-4 U-1 0 U 0 r-4 U4 ar:!l < Z r-4 Z C%4 11i Ln _J Lij I UJ X X < f%4 < Z IT Z L co Z LU 0 0 r�- 15 Z: 9 rn T-q Ia. (n SCALE AS NOTED DATE 2/24/2014 TECH: FLORES VERSION NO - 10 SHEET NO. 2.0 � SEE PLAN FOR LANDING DEPTH NOTE: FIN. TO HAVE TRADITIONAL LOOK & SMOOTH FINISH FOAM/ EPS MATERIAL IS ACCEPTED 9 LO z co NOTCH FOAM DECO BRACKET AS NEEDED J -4.1 )PECORATIVE SHUTTER. 12 5 12 Z:::::�5 1 - - - - - - - - - - - - - - - - -- - - - - - -- t - - - - - - - - - - - - - - - t - - - - - - - - 18" X 60" SHUTTER—, - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - t__1 -- - - - - - -- --------------------------------------- ------------- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ­7 o T.O.P. 1" x 12" C% SMOOTH TEXTURED -17DIRA I MAKIM 00 UJ LU 25 SH 2nd FIN. FLR. T.O.M. L HDR HGT. __ ___A1L — — — — — — 11L — — — — — — EL A — — — — L — A J 1 J___L . . . . . . . . . . . . . . . . . . . . . . . L _ _ F.FL. FRONT ELEVATION - A SCALE: 1/4"=V-0" T.O.P - — — — — — — — HDR HGT. C� 2nd FIN. FLR. T.O.M. RIGHT ELEVATION - A SCALE: 1/4"=V-0" 00 11 General Notes ROOF CRITERIA: 12" OVERHANG U.N.O. PLUMB CUT FASCIA ROOF PITCH PER ELEVATION **G.C. VERIFY ROOF PITCH" ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE CONTRACTORS RESPONSIBILITY TO VERIFY ROOF SLOPE REQUIREMENTS WITH TRUSS MANUFACTURER. "ELECTRICAL SPECIFICATION NOTES" ELECTRICAL CONTRACTOR MUST VERIFY WITH THE SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT FIXTURES SHOWN ARE FOR LOCATION PURPOSES. Exterior Covering R703.6 Exterior plaster. Installation of these materials shall be in compliance with ASTM C 926 and ASTM C 1063. R703.6.1 Lath. All Lath and lath attachments shall be of corrosion -resistant materials. Attached per ASTM C 1063. R703.6.2 Plaster. Plastering w/ portand cement plaster shall be not less than three coats when applied over metal lath or wire lath and shall be not less than two coats when applied over masonry, concrete. R703.6.3 Water-Resisitive Barriers. Water-resisitive barriers shall be installed where cement plaster (stucco) is to be applied over wood -based sheathing, shall include a water -resistive vapor -permeable barrier. The individual layers shall be installed independently such that each layer provides a separate continuous plane and any flashing intended to drain to the water -resistive barrier is directed between the layers. The barriers shall consist of one of the following. 1. Two layers of an approved water resistant barrier material in accordance with R703.2. 2. One layer of an approved water -resistive barrier (paperbacked stucco lath) over an approved synthetic house wrap. R703.8 Flashing. Approved corrosion -resistant flashing shall be applied shingle -fashion in a manner to prevent entry of water into the wall cavity or penetration of water to the building structural framing components. Flashing shall be installed at the following locations. • Exterior window/door openings. • Intersection of chimneys or other masonry contructions with frame walls. • Under and at the ends of masonry, wood or metal copings and sills. Continuously above all projecting wood trim. Where exterior porches, decks or stairs attach to a wall or floor assembly of wood -frame construction. At wall and roof intersections At Built-in gutters. Attic Ventilation Attic Ventilation to be in compliance with the Florida Building Code 5th Edition (2014) Residential R806. The Minimum net free ventilating area shall be 1 /150 of the area of the vented space. The ventilating area may be reduced to 1/300 provided that at least 40% but no more than 50% of the required ventilation is provided in the upper portion o the space to be ventilated.Upper ventilators shall be located no more than 3 feet (measured vertically) below the ridge or highest point of the space, with the balance of the required ventilation provided by eave or cornice vents. -CALCULATIONS BASED ON THE FOLLOWNG VALUES, SEE ROOF PLAN - (Values to be verified with Manufacturer Specifications) RIDGE VENTS 15 SO. IN. OF NET FREE AREA/ LINEAR FT. OFF -RIDGE VENTS 138 SQ. IN. OF NET FREE AREA / UNIT SOFFIT VENTS 7 SQ. IN. OF NET FREE AREA / SQ. FT. *If not enough vented soffit is provided due to fire protection, the contractor shall use the following approved vents: • LOMANCO DECK-AJR (Shingle Roo - 9 SO. IN. OF NET FREE AREA/ FT. Formula: (Sq. Ft. Soffit Needed) x 7 = (Sq. In. Needed) / 9 = (Linear Ft. of Deck -Air Needed) • O'HAGIN (Tile Roof) - 86.25 SO. IN, OF NET FREE AREA / VENT �Formula: (Sq, Ft. Soffit Needed) x 7 = (Sq. In. Needed) t 86.25 a Amount of O'Hagin Vents Needed 0 Z —8 z CD z z V) (D Q) U-) 4-J LU C) U 0 LU V) E 0 C) M 04 0) Cl) LU F_ E — 8 02, C) U) 0 < CL 0 Ot A I B N,1, B-D-C Ul) Cn 00 Z ce) 11 Ul z CAW to 8% F z LLW C9 0 F E C', nfill E-100 To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code Sth Edition (2014) Residential. Engineer's signature and sea[ is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. 0 CD z N 0 cu N 0-4 4_J C:) �04 U) CMY) 0 4-J V) (V Ln 00N Q) — Ln < - U_ 0� U 00 z E z CD WLU _J C:) z W Z 0 5-080 BUZ — < :> U LU _J 8 0 Ln LU LU Z z -0 N C) Ln Fn 0 U < uJ 0 rr 5 :6 (-4 LL U4 2r:j � j g < r4 uJ ce g 0 I z z N LU Ln ­1 1 6i Z < z di z < z t—u Oil �10 14r r-4 V- Cal 0 r-1 r�l Z LLI CL V) SCALE AS NOTED DATE 2/24/2014 TECH: FLORES VERSION No' 10 SHEE7 NO. 3.1 12 5 F�:� 12 Z:::Z15 T.O.P. HDR HGT. Ci Ci Ci 2nd FIN. CJ WEEP CJ / WEEP FLR. T.O.M. ---- — — — — — — — — — — — — — — — — — — — — — - — — — — — — — — — HDR HG ROOF TO BE 0 _IU CENTERED ON TEXTURED DOOR CEMENTICIOUS FINISH ON C.M.U. ILI (TYP.) -A 11==R"�W L F.FL. REAR ELEVATION - A SCALE: 1/4"=V-0" 12 5F�:� 12 ��5 9'RIDGE VENT 04 00 I P. T.O.P. - - - - - - - - - - - - - - - - - - - - - HDR HGT. -------------------------------------------- ------------------------------------------------------- Z 04 ---- - -- ----------------- 2nd FIN. FLR. T.O.M. HDR HG -------------------------------------------------------------------------------------------------------- -TEXTURED —Z CEMENTICIOUS Z///FINISH ON C.M.U. (TYP.) I J L__] F.FL. LEFT ELEVATION - A SCALE: 1/4"=V-0" F_ 19 General Notes ROOF CRITERIA: 0 12" OVERHANG U.N.O. 0 PLUMB CUT FASCIA ROOF 0 PITCH PER ELEVATION "G.C. VERIFY ROOF PITCH" ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE CONTRACTORS RESPONSIBILITY TO VERIFY ROOF SLOPE REQUIREMENTS WITH TRUSS MANUFACTURER. "ELECTRICAL SPECIFICATION NOTES" ELECTRICAL CONTRACTOR MUST VERIFY WITH THE SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT FIXTURES SHOWN ARE FOR LOCATION PURPOSES. Exterior Covering R703.6 Exterior plaster. Installation of these materials shall be in compliance with ASTIVI C 926 and ASTIVI C 1063. R703.6.1 Lath. All Lath and lath attachments shall be of corrosion -resistant materials. Attached per ASTIVI C 1063. R703.6.2 Plaster. Plastering w/ portland cement plaster shall be not less than three coats when applied over metal lath or wire lath and shall be not less than two coats when applied over masonry, concrete. R703.6.3 Water-Resisitive Barriers. Water-resisitive barriers shall be installed where cement plaster (stucco) Is to be applied over wood -based sheathing, shall include a water -resistive vapor -permeable barrier. The individual lay shall be installed independently such that each layer provide:r: separate continuous plane and any flashing intended to drain to the water -resistive barrier is directed between the layers. The barriers shall consist of one of the following. 1. Two layers of an approved water resistant barrier material in 2. One layer of an approved water -resistive barrier (paperbacked stucco lath) over an approved synthetic house wrap. R703.8 Flashing. Approved corrosion -resistant flashing shall be applied shingle -fashion in a manner to prevent entry of water into the wall cavity or penetration of water to the building structural framing components. Flashing shall be installed at the following locations. Exterior window/door openings. Intersection of chimneys or other masonry contructions; with frame walls. Under and at the ends of masonry, wood or metal copings and sills. Continuously above all projecting wood trim. Where exterior porches, decks or stairs attach to a wall or floor assembly of wood -frame construction. At wall and roof intersections At Built-in gutters. Attic Ventilation Attic Ventilation to be in compliance with the Florida Building Code 5th Edition (2014) Residential R806. The Minimum net free ventilating area shall be 1/150 of the area of the vented space. The ventilating area may be reduced to 1/300 provided that at least 40% but no more than 50% of the required ventilation is provided in the upper portion oi the space to be ventilated. Upper ventilators shall be located no more than 3 feet (measured vertically) below the ridge or highest point of the space, with the balance of the required ventilation provided by eave or cornice vents. -CALCULATIONS BASED ON THE FOLLOVANG VALUES, SEE ROOF PLAN - (Values to be verified with Manufacturer Specifications) • RIDGE VENTS 15 SO. IK OF NET FREE AREA/ LINEAR FT. • OFF -RIDGE VENTS 138 SO. IN. OF NET FREE AREA / UNIT • SOFFIT VENTS 7 SO. IN. OF NET FREE AREA I SO. FT. *If not enough vented soffit is provided due to fire protection, the contractor shall use the following approved vents: e LOMANCO DECK-AJR (Shingle Rool - 9 SO. IN. OF NET FREE AREA I FT. "Formula: (Sq. Ft. Soffit Needed) x 7 = (Sq. In. Needed) / 9 = (Linear Ft. of Deck -Air Needed) e O'HAGIN (Tile Rool) - 86.25 SO. IN. OF NET FREE AREA / VENT -Formula: (Sq. Ft Soffit Needed) x 7 = (Sq. In. Needed) / 86.25 = Amount of O'Hagin Vents Needed z Cl) C� z z U) Ul 0 Z Q) C—n 4-J uj U 0 UJ E Ul) 0 00 C) r-- 04 a) M LLJ E 0) cr) C MM w *0 - - 'C C14 0 0 C, C_ LL Cc 0 CD a 0 .1d < 0 0 'W 0. < ci A I ab. N CA1,11,17 I , V J��o W 4). 00 U_ C CM. CL W L 4 C z M RFESS M 0 El To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code Sth Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. C) C) Z 04 0 a) N 1­4 4-J C) > V) C) m Ln z 0 LL F- Q� U CL 00 z < . E z �: (0 z LU C) F- _J 0 W z g i � F� U) 0 F- z 1 < �q �> UJ U12.8 91 ti I.- ui V) 0 U-) LMU �z z -0 N Ln U) > 0 0 U Ln < CC LU Cr 85 Vr4 P z z C"4 r-4 LU -J Ln I z 4:lt co z z :5 t_U LU 0 rn T-4 0- M: V) uJ SCALE AS NOTED DATE 2/24/2014 TECH: FFLORES VERSION No' 10 SHEET NO. 3.2 ELECTRICAL SPECIFICATION NOTES: ELECTRICAL CONTRACTOR MUST VERIFY WITH THE SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT FIXTURES SHOWN ARE FOR LOCATION PURPOSES. ---------------------------------------------- GENERAL ELECTRICAL NOTES: Notes: unless otherwise noted, 1 . Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF (general) kitchen 44" AFF bathroom 39" AFF laundry room 36" AFF exterior waterproof 12" AFF garage general purpose 42" AFF range 2" AFF 2. All trim plates & devices to be ganged, where possible. 3. Electrical switches to be at 42" centerline above finished floor. 4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the installation & sizing of all electrical, wiring & accessories. 5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. 6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch circuits in all dwelling units per NFPA 70 and the 2011 NEC. 7. Provide Tamper Resistant Receptacles as required by the 2011 NEC, 406.11 8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and vapor detector sensor, according to the installation. 9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a Nationally Recognized Testing Laboratory. 10. Keep all smoke detectors minimum of 36" from bathroom doors 11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be equipped with a monitored battery backup. 12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits is not acceptable. 13. All doors and windows providing direct access from the home to the pool shall be equipped with an exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning when the door or window are opened.. 14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' if the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacles outlests shall not be required on a wall directly behind a range or sink to fulfill the requirement for an outlet every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and 18" for sinks and ranges installed in corner counters. I ELECTRICAL KEY I DUPLEX CONVENIENCE OUTLET FfF DUPLEX OUTLET ABOVE COUNTER �@W.P. WEATHERPROOF DUPLEX OUTLET kz=_ r'ZV-G . F.I. GROUND FAULT INTERRUPTER DUPLEX OUTLET I /-\ pi -IF HALF -SWITCHED DUPLEX OUTLET L.,�;Ih SPECIAL PURPOSE OUTLET DUPLEX OUTLET IN FLOOR 220 VOLT OUTLET $ WALL SWITCH $3 THREE-WAY SWITCH 24 FOUR-WAY SWITCH $R RHEOSTAT SWITCH CEILING MOUNTED LIGHT FIXTURE WALL MOUNTED LIGHT FIXTURE RECESSED LIGHT FIXTURE LIGHT FIXTURE WITH PULL CHAIN TRACK LIGHT FLOURESCENT LIGHT FIXTURE POWER CO. FEED INTERSYSTEM BONDING TERMINATION PER NEC 08,250.94 —/ 200A INDOOR PANEL CENTER CLAMP PER 250.50 AND 250.52 OF THE 2011 NEC. opper to lights & outlets opper to 20 amp clas copper to WH copper to Dryer t Alu Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE PROVISIONS OF THE NFPA 70 - 2011, LOCAL CODES AND THE LOCAL POWER CO. EXHAUSTFAN GFI F1 ___Wj F _IM�4114 APFI:11 1 Ak 11 F-1 I tLLU I HIUAL FANtL EXHAUST FAN/LIGHT COMBINATION ELECTRIC DOOR OPERATOR (OPTIONAL) DEDICATED RECEPTACLE VERIFY METER FOR MICROWAVE RANGE ICH CHIMES (OPTIONAL) HOOD PER SPECS LOCATION WITH BUILDER 11 PUSHBUTTON SWITCH (OPTIONAL) @ SMOKE DETECTOR SMOKEICARBON MONOXIDE DETECTOR (COMBO UNIT) TELEPHONE (OPTIONAL) TELEVISION (OPTIONAL) W 2 (2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. THERMOSTAT ELECTRIC METER owl ELECTRIC PANEL __M1=L DISCONNECT SWITCH llc�% SPEAKER (OPTIONAL) ROUGH -IN FOR OPT. CEILING FAN CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR </ OPT. CEILING FAN (1) PHONE LINE, (1) DATA PORT MAIN FLOOR ELECTRICAL PLAN SCALE: )/4"=1'-0" 0 Z Z Z Z V) (D Q) C-111) u, 0 LLJ L104) 1(2� D U E 0 2 V) M .2 8 4) cn E 8 C" (1) C M Cl) �MS 0 000 - = LL 00 = - 00 0 M < 00) CD D,j C,4 to .00, 04 Z Z cS Z r, c—.3 WIN 04.)! 2 T rZ 4M. ILL ILL in J, LU LLI a- CL 2� 0 'M It` Zco LL X co IM cm X < M _j W UJI Pn El 11 0 To the best of the Engineer's knowledge, Information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code Sth Edition (2014) Residential. Engineer's signature and seal Is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. 0 Z 0 > C� V) p M Ln V) 0 U_ F- a> � fo ct� U a 00 Z < . E Z3: Z LU C� _j 0 W 11.0 lir mi Z,< Z Z bZ80 ce U, Z 0 Ln b Z -0 (0 N Ln LLJ __j Uj > 0 U 0 0 _j U_ 0 i:-U agg :Z 0 CLY_ < Z a uj be Z Uj Ln LU Z < < Z LU;5 r_j Z Z 0 N :5 LU rn T-4 SCALE AS NOTED DATE 2/24/2014 TECH: FLORES VERSION NO' 10 SHEET NO. 4.0 ELECTRICAL SPECIFICATION NOTES: ELECTRICAL CONTRACTOR MUST VERIFY WITH THE SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT FIXTURES SHOWN ARE FOR LOCATION PURPOSES. GENERAL ELECTRICAL NOTES: Notes: unless otherwise noted, 1 . Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF (general) kitchen 44" AFF bathroom 39" AFF laundry room 36" AFF exterior waterproof 12" AFF garage general purpose 42"AFF range 2" AFF 2. All trim plates & devices to be ganged, where possible. 3. Electrical switches to be at 42" centerline above finished floor. 4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the installation & sizing of all electrical, wiring & accessories. 5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. 6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch circuits in all dwelling units per NFPA 70 and the 2011 NEC. 7. Provide Tamper Resistant Receptacles as required by the 2011 NEC, 406.11 8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and vapor detector sensor, according to the installation. 9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a Nationally Recognized Testing Laboratory. 10. Keep all smoke detectors minimum of 36" from bathroom doors 11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be equipped with a monitored battery backup. 12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits is not acceptable. 13. All doors and windows providing direct access from the home to the pool shall be equipped with an exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning when the door or window are opened.. 14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' if the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacles outlests shall not be required on a wall directly behind a range or sink to fulfill the requirement for an outlet every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance from the sink or range is greater the 12"for straight counter tops and 18" for sinks and ranges installed in corner counters. I ELECTRICAL KEY I 1_� DUPLEX CONVENIENCE OUTLET DUPLEX OUTLET ABOVE COUNTER F3W.P. WEATHERPROOF DUPLEX OUTLET GROUND FAULT INTERRUPTER DUPLEX OUTLET HALF -SWITCHED DUPLEX OUTLET SPECIAL PURPOSE OUTLET DUPLEX OUTLET IN FLOOR 220 VOLT OUTLET WALL SWITCH $3 THREE-WAY SWITCH �4 FOUR-WAY SWITCH $R RHEOSTAT SWITCH CEILING MOUNTED LIGHT FIXTURE WALL MOUNTED LIGHT FIXTURE RECESSED LIGHT FIXTURE +P.C. LIGHT FIXTURE WITH PULL CHAIN TRACK LIGHT FLOURESCENT LIGHT FIXTURE POWER CO. FEED INTERSYSTEM BONDING TERMINATION PER NEC 08, 250.94 —/ 200A INDOOR PANEL CENTER CLAMP PER 250.50 AND 250.52 OF THE 2011 NEC. Dipper to lights & outlets DPPet to 20 amp ckts copper to WH copper to Dryer I Alu Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE PROVISIONS OF THE NFPA 70 - 2011, LOCAL CODES AND THE LOCAL POWER CO. EXHAUSTFAN IWO EXHAUST FAN/LIGHT COMBINATION ELECTRIC DOOR OPERATOR (OPTIONAL) F nCH CHIMES (OPTIONAL) SYSTEM El PUSHBUTTON SWITCH (OPTIONAL) @ SMOKE DETECTOR SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) TELEPHONE (OPTIONAL) TELEVISION (OPTIONAL) 2 (2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. THERMOSTAT ELECTRIC METER owl ELECTRIC PANEL _A§_j DISCONNECT SWITCH f1cp% SPEAKER (OPTIONAL) ROUGH -IN FOR OPT. CEILING FAN <1/ <��/> CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR </ li�\_ OPT. CEILING FAN �e (1) PHONE LINE, (1) DATA PORT E�] UPPER ELECTRICAL PLAN SCALE: Y4"=1'-0" tn Z ZOE U) Z Ln (D UJI 0 U 0 LU V) 01- =3 E 0 2 co 0 C14 U-J! E 8 Q) CO 0.) M C21) 27S2 0.20 �s U_ 0 M CL 0 \1 < 0 to 0 V CL < Al CN LQ M &0 LO qr IAZ m 0 6 6 0 0 S. . M W 4F rX Inn, S [L- _' .2 C5 cm, ILL. LJ_ LU LU U Z & CL LLJ ILL, Z 0011 PC. 0. cr_ 00 Z 2 b Lu till 0) LL V;�c N .4 C 54 0 To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code Sth Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. I 0 Z r*4 0 a) N C:) U0 rn p 1`0 Lr) a) Ln ro cl� U CL 00 Z < . E Z3: M Z UJ C:) _j a W kD Z. Z p� a- U uj I ti- ZZ < Lu Zo -.j 0� 8 LL C) M!-, � U-) b Z 0 -a Uj Ln LU > r'4 0 U V) 0 ILL- LU Igg 0 C-4 < < C%4 < �r Z Z r*4 gn Ln di Z < 66� ffe 45 < Z Z t7u co 0 z �0 SCALE AS NOTED DATE: 2/24/2014 TECH: FLORES VERSION NO' 10 SHEET NO. 4.1 ®r VENTED SOFFIT 40 SQ %/I=:KI-rI=M Cn=1-r A I C%n 11=7117 V L_ 1 14 1 L_ LJ %J %.J I I I I It %J %J W. I I . _ATTIC VENTILATIONCALCULATIONS ATTIC VENTILATION REQUIRED 1/150 Rule 1/300 Rule --A, UPPER VENTILATION PROVIDED Ridge Off -Ridge (No Upper Ventilators (Must Provide Upper Ventilators) Vent Amt Amt. Req.) (Ft.) Total Ventilation ATTIC Provided SPACE SQ. FT. Total SQ. SQ. FT. SQ. IN. of by Upper SQ. IN. of of ventilation to ventilation of vented IN. of vented be provided SQ ' IN. of SQ. IN. of Ventilators (See Elev) required soffit ventilation soffit by upper Ventilation Ventilation needed required needed ventilators Main 0.000000 0.000000 Floor 0 0 0 0 0 0 0.0 (Zone 1) 0.0 0.0 Upper 9 2.000000 Floor 1535 1474 211 737 53 368 411.0 (Zone 2) 1 1 1 1 1 135.0 276.0 '*NOTE'* GENERAL CONTRACTOR MUST ENSURE THAT PROPER VENTILATION IS PROVIDED AT EAVES/SCIFFITS AS REQUIRED BY FBC 5th ED. RESIDENTIAL. VENTEP-SOFFIT LEGEND- 7—/q IF SOFFIT IS LABELED AS "NON -VENTING" FIRE PROTECTION WILL BE INSTALLED A AS REQUIRED BY SECTION R302 OF THE FBC 5th EDITION (2014) RESIDENTIAL. IF LABELED ASWENTED", NO FIRE PROTECTION WILL BE REQUIRED. ............ ......... ..... VENTED SOFFIT ENTED SOFFIT SQ. FT. ZONE-1 ATTIC SPACE 35 SQ. FT. 'ENTED SOFFIT SQ. FT. OFFIT 25 SQ. FT. ROOF PLAN. SCALE: Y4"=V-0" General Notes ROOF CRITERIA: 0 12" OVERHANG U.N.O. 0 PLUMB CUT FASCIA ROOF 9 PITCH PER ELEVATION "G.C. VERIFY ROOF PITCH" ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE CONTRACTORS RESPONSIBILITY TO VERIFY ROOF SLOPE REQUIREMENTS WITH TRUSS MANUFACTURER. "ELECTRICAL SPECIFICATION NOTES" ELECTRICAL CONTRACTOR MUST VERIFY WITH THE SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT FIXTURES SHOWN ARE FOR LOCATION PURPOSES. Exterior Covering R703.6 Exterior plaster. Installation of these materials shall be in compliance with ASTM C 926 and ASTM C 1063. R703.6.1 Lath. All Lath and lath attachments shall be of corrosion -resistant materials. Attached per ASTM C 1063. R703.6.2 Plaster. Plastering w/ portland cement plaster shall be not less than three coats when applied over metal lath or wire lath and shall be not less than two coats when applied over masonry, concrete. R703.6.3 Water-Resisitive Barriers. Water-resisitive barriers shall be installed where cement plaster (stucco) is to be applied over wood -based sheathing, shall include a water -resistive vapor -permeable barrier. The individual layers shall be installed independently such that each layer provides a separate continuous plane and any flashing intended to drain to the water -resistive barrier is directed between the layers. The barriers shall consist of one of the following. 1. Two layers of an approved water resistant barrier material in accordance with R703.2. 2. One layer of an approved water -resistive barrier (paperbacked stucco lath) over an approved synthetic house wrap. R703.8 Flashing. Approved corrosion -resistant flashing shall be applied shingle -fashion in a manner to prevent entry of water into the wall cavity or penetration of water to the building structural framing components. Flashing shall be installed at the folloWng locations.. • Exterior window/door openings. • Intersection of chimneys or other masonry contructions with frame walls. • Under and at the ends of masonry, wood or metal copings and sills. • Continuously above all projecting wood trim. • Where exterior porches, decks or stairs attach to a wall or floor assembly of wood -frame construction. At wall and roof intersections At Built-in gutters. I I Attic Ventilation Attic Ventilation to be in compliance with the Florida Building Code 5th Edition (2014) Residential R806. The Minimum net free ventilating area shall be 1/150 of the area of the vented space. The ventilating area may be reduced to 1/300 provided that at least 40% but no more than 50% of the required ventilation is provided in the upper portion of the space to be ventilated. Upper ventilators shall be located no more than 3 feet (measured vertically) below the ridge or highest point of the space, with the balance of the required ventilation provided by eave or cornice vents. -CALCULATIONS BASED ON THE FOLLOWING VALUES, SEE ROOF PLAN** (Values to be vedfied with Manufacturer Specifications) • RIDGE VENTS 15 SO. IN. OF NET FREE AREA / LINEAR FT. • OFF -RIDGE VENTS 138 SQ. IN. OF NET FREE AREA / UNIT • SOFFIT VENTS 7 SQ. IN. OF NET FREE AREA / SQ. FT. *If not enough vented soffit is provided due to fire protection, the contractor shall use the following approved vents: 9 LOMANCO DECK -AIR (Shingle Roof) - 9 SQ. IN. OF NET FREE AREA / FT. **Formula: (Sq. Ft. Soffit Needed) x 7 z (Sq. In. Needed) / 9 - (Linear Ft. of Ceck-Alr Needed) 0 O'HAGIN (Tile Roof) - 86-25 SQ. IN. OF NET FREE AREA / VENT "Formula: (Sq. Ft. Soffit Needed) x 7 = (Sq. In. Needed) 186.25 - Amount of O'Hagin Vents Needed (D z co —80 z CD z Z C3 V) (D Q) C—/) 4--J Lu 0 U 0 LU 0 V) 00 FM i- E 8 04 4) co 0) C M C') T.S,04 0.g (31 g ii LL =,i co 0 x CL 0 < 0 N C 13 D C X f4L. e®r E— 11\ a co CO 0 gg FL 7.4m M .-Mill 'a Li:,o inz cc F E S'S Z IL JU < 11,1111114% N M UWJ In 0 EJ LJ To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code Sth Edition (2014) Residential. Engineer's signature and seal Is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. Z r4 0 (v r-, 0­4 C) U0 tD > U.) rn c) C:) N U-) f0 Lr) 0 LL 0� U z < CL OC) z E z M UJ F- _J C:) W 110 z 480, z H �J z Elu, X _J 0�q§ 0 Ln z -a N LL0 0 U U-) r*4 U_ 0 —4 f-4 0 do 1,81 1 i:9 2i*:;I < z r*4 Lu z LU (**4 L0 Lli < < z P r,j z z t—u 0 r-11 SCALE AS NOTED DATE 2/24/2014 TECH: FFLORES VERSION No' 10 SHEE7 NO. 5.0 C 6'-4" 1. 6'-0" 6 6'-0" 6 6'-0" TYP @ 2 STORY H.B.T T 2 Z-238" , 2'-1 .......... !IIII! ................. 0 ............ ..E ......... !IIII!! .............. 0 ..... E... W S3 o? 5 16'-3" HVAC CHASE 01-01, BASED ON I LOCATION INDICATES FILLED CELL w/ 3000 PSI CONC. GROUT FROM FT. TO F17. BEAM W/ (1) #5 REBAR VERT 1* ......... . ABOVE SLAB TYP @ ALL PLACES C� 10 I 6-4"" SHOWN HOOKED FTG. DOWELS 5" 2 EMBED W/ 25" EXT. ABOVE SLAB "GRADE 40 STEEL" TYP @ 2 STORY 9 b 04 C� CO L _j Ci 7 Ci rd� 2'-6" 2'-6' x x 1, 3 ISTUBUPTO W/ (3) #5'S E.W. 04 13'-7 2ND FLOO FOR A/C .... J: TOP OF CONCJ PAVER T 0 BE 4' z rL \Z3 BELOW FIN. FLR. 2'-6" x 2'-6" x V-0" PROVIDE Y2" x 91, SLOPE TYP @ 2 STORY RECESS FOR FRT. DOORjj L_ .0. 1 -31/2" c� W/ (3) #5'S E.W. - - - - - - Eln" Ci F (2) #5 REBAR q BUILDER TO PROVIC E VERTICALS w/ in 3000 PSI CONC. �TION -3 1/2" 3-1/2" MIN APPLIANCE PROTEC FILLED CELL 1 PROVIDE 1 y2" SLAB FOR HERNANDO WHEN REQUIRED PER FBC 2STORY 9 RECESS FOR COUNTY ONLY &D SGD. REFER TO 3 -1/2" MIN 2500 PSI CONC MASON'S SLOPE SLAB OVER 6 MIL L FOR WIDTH VISQUEEN VAPOR BARRIER STEPS AS CHASE REQUIRED PER TO C? FIELD CONQJTJONS KITCHEN ISLAND S LOW W S &-31/2" -SLbPE-' — — -- — — — — — — — 9 &D 'T I L Ci C14 _-4— Ci V �:I all I ; 1: 4'-l'V I 1 . L__ — -ii z 4" re- --% o? I 1 71, co rT L - - - - - - - - - - - IlL 11 r- 01-01. U, (2) #5 REBAR 67� VERTICALS w/ in \ �3 FILLED CELL (0 9 2STORY ro L _j C� . ............... i . . . . . - - In __% * , ii—, *.' , ....... 0 N H.B4 TYP @ 2 STORY 6-4- 6-0" 6'-0" 6'-0" 64" 4'-0" FOUNDATION PLAN SCALE: Y4"=1'-0" NOTE: • WHERE PROJECT IS TO BE LOCATED IN KNOWN RADON GAS PREVALENT AREAS, APPENDIX "E- OF THE FBC 5th EDITION (2014) BUILDING IS TO BE IMPLEMENTED. CONCRETE STRENGTH IN THESE AREAS TO BE A MINIMUM OF 3000 P.S.I. THEREFORE, ANY AND ALL NOTES ON THESE PLANS THAT INDICATED 2500 P.S.I. SHALL BE REPLACED WITH 3000 P.S.I. FOR THE CONCRETE STRENGTH • SEE SHEET SN FOR SOIL & TERMITE NOTES. BORATE / BORACARE TREATED LUMBER IS AN ALTERNATE TERMITE PROTECTION TO SOIL POISONING W.W.M. PLACED IN —1/8" SAWCUT x 1/4 SLAB UPPER 1/3 OF SLAB THICKNESS WHERE OR FIBERMESH SHOWN ON REINF. SEE PLAN.-� FOUNDATION PLAN LF LU 'LU) CONTROL JOINT DETAIL. SCALE: 11/2"04" j v- v. v- v, #5 CONT REINF. SEE FND. FOR QUANTITY #5 X 25" X 25" CORNER BAR ONE FOR EA. HORIZ. REBAR, TYP. U.N.O. **Alternate: rhe reinf. bars shall be cont. around corner by cold bending the bar w/ min. bar lap of 25". TYP. CORNER BAR DTL. SCALE: 1 1/2"=V-0" 0 (D_ Z: ce) z < U) Z: C V) 0 (L) _/) c 4--J LU 0 U 0 LLj E U0 0 c) F__ E CNI) 0) ce) r_ M Cl) 2 7 2 c,1Q 0 Z5 0 a: 00 00 ca — CL 0 < - 0 Cm 0 .t Ci A I I D. r 9__ 0 UL .C, X 0 CL --G Z FU_ I "i fL , fL 0- hu R ';e z F E, A Ot 0 M To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code Sth Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. 0 C) Z r-4 0 (L) N 1­4 4-J C� 15 %0 CD LF) cn C:, M C) 4-1 . N V) M Lr) z 0 "N (U In C F- C>,L U CL z 00 z § E ­-0 z c) WLU _j 0 ,,u z 0, CL z u-, jui 0 IN �j (g, F- LLI F- 0 Ln z -0 r*-% Lr) r'-4 0 LL U 0 0 uj Lu Cx z z ('*4 -2 LU _j Ln di Lij z Lu r-4 Z LU U, A SCALE AS NOTED DATE 2/24/2014 TECH: FLORES VERSION No' 10 SHEET NO. 6.0 LIA J! -a i� 'KING UPLIFT CONNECTION CROSS-REFERENCE MARK SIMPSON STRONG TIE USP MANUFACTURING, INC. 0 CONNECTOR CAPACITY FASTENERS CONNECTOR CAPACITY FASTENERS SYP SPF SYP SPF A HETA20 1810 9 - 10d x 1 1/2" HTA20 1615 1585 10 - 10d x 1 1/2" B HETA16 1810 9 - 10d x 1 1/2" HTA16 1615 1585 10 - 10d x 1 1/2" C H2.56 600 535 10 - 8d RT7A 670 565 10 - 8d X 1 1/2" D H3 455 320 8 - 8d RT3 610 525 8 - 8d X 1 1/2" E META20 1450 7 - 10d x 1 1/2" HTA20-18 1400 1400 10 - 10d X 1 1/2" F HHETA20 2235 10 - 10d x 1 1/2" G H10A 1340 1015 18 - 10d x 1 1/2" RT16A 1380 1160 9-1 Od X 1 1/2% 8-1 Od H HTT4 3610 3105 5/8" ANCH. 108) 10dxl-1/2 HTT4 2715 518"ANCH. /(20) 10dxl-1/2 HTT5 4350 3740 5/8"ANCH. / (26) 10dxl-112" HTT5 3225 518- ANCH. /(28) 10dxl-1/2 3130 3050 518"DIA. BOLTS TDX2-TZ 2345 — 12 - 5/8- DIA. BOLTS L 4505 3785 5t8"ANCH. 3/4"STUD BOLTS TDX6 5320 — 12 - 7/8" DIA. BOLTS M 6645 5650 7/8"ANCH. 314" STUD BOLTS TDX1 0 7845 — 4 - 7/8" DIA. BOLTS N LUS26 1165/1070 1005/915 8 - 1 Od x 3" JUS26 1115/1060** — 8 - 1 Od P HUR26 1550/3335 1335/2820 20 - 16d x 3 1/2" HUS26 1925/3295 — (20)16d x 3-1/2" Q HUS28 2000/4220 1720/3125 30 - 16d x 3 1/2" HUS28 2570/4345 — 30d -1 6d x 3-1/2" R MTS12 1 1000 860 14 - 1 Od x 1 1/2" MTW12 1195 1005 14-1 Od x 1-1 /2" S MTS16 1000 860 14 - 1 Od x 1 1/2" MTW16 1195 1005 14-1 Od x 1-1 /2" T MTS20 1000 860 14 - 1 Od x 1 1/2" MTW20 1195 1005 14-1 Od x 1-1 /2" U MGT/MUGT 1 3140 3140 22 - 10d X (1) 5/8"ATR W/ 5" EMBED W/ SIMPSON "SET" EPDXY V LGT2 2150 1850 (16)16d SINKERS & (7) 1/4" x 2-1/4" TITENS LUGT2 1850 1810 (16)1 Od NAILS AND (5) 1/4" x 3" WEDGE BOLTS "X11 HTS 20 1450 1245 24-1 Od X 1 1/2" HTW20 1530 1285 24-1 Od X 1 1/2" spi 585 1 535 0 - 10d 10 I SPT22 685 8 - 10d 605 f12 - 10d SPT24 1030 1 12 - 10d HCP2 645 555 1 12-1 Od X 1 1/2' 1 1 MINIMUM WMEMBER REACTIONS ARE FOR ROOF LOADS ONLY DO NOT DRIVE NAILS THROUGH THE TRUSS PLATE ON THE OPPOSITE SIDE OF THE TRUSS, WHICH COULD FORCE THE PLATE OFF OF THE.TRUSS. ALL EPDXY ANCHORS USP CIA-7000C NOTE: DOUBLE FELT REQ'D ON ROOF PITCHES 3/12 & LOWER. LOADS -- ROOF = L / 360 FLOOR = L / 480 W/ 3/8" MAX DEFLECTION. FLOOR JOIST SPACING SHALL BE MAX OF 19.2"OC FOR HARDWOOD & TILE AREA'S & 24" OC FOR CARPET AREA'S DROP HIP DETAIL. 2-0-0 MAXIUM SPACING ON VERTICALS OF (B) TRUSS A r\\ I+ +) A I I (B) (A) A 11 11 11 1 11 11 1"�l OR 2 PLY Fri/ I I CARRIER 1-8-8 CLEAR GAP BETWEEN (B) TRUSSES 6") 'FASTEN EACH (B) TRUSS WEB TO EACH (A) TRUSS TOP CHORD @ EVERY INTERSECTING POINT SHOWN ON THE HIP TRUSS SYSTEM BELOW. FASTEN TOP CHORDS OF EACH (B) TRUSS TO THE TOP CHORDS OF (A) TRUSSES AT EVERY OTHER INTERSECTING POINT ("). (B INTERSECTING POINT TO BE FASTENED WITH 2 - 16d COMMON NAILS OR 0. 1 28"x 3"GUN NAILS. FASTEN BOTTOM CHORD OF (B) TRUSS TO TOP CHORD OF CARRIER TRUSS WITH THE SAME SPECIFIED COMMON NAILS OR GUN NAILS AT 48" OC. (+) IN LIEU OF PREFABRICATED HIP PLANING TRUSSES, (B) 2A SO. PINE #2 OR #2 PT. STICK LUMBER (LAID FLAT WISE) MAY BE USED. FOLLOW FASTENING SCHEDULE AS DEFINED FOR HIP PLANING TRUSSES. R1 STICK FRAMING SPLICING IS ALLOWED BETWEEN TRUSSES OR AT TRUSS 1 OR 2 P Y ER—j —(A)— &NTM INTERSECTIONS. SPLICING 2x C TO BE STAGGERED BETWEEN COMMON TRUSSES, NO CATS REQUIRED UNDER STICK FRAMING SPLICING. MINIMUM LENGTH OF STICK FRAMING TO BE 5'-01' ON A HORIZONTAL PROJECTION. NU I L: bEtz bH[=L I U-1 I-UR ROOF FRAMING DETAILS 1. (2) 12d TOENAILS EACH SIDE OF FLOOR TRUSS TO WALL OR BEAM BELOW TYP @ INT. BEARING U.N.O. STRUCTURAL SHEATHING (SEE TB1 3 FOR NAILING INFO.) — 2x CONT. W/ (2)-12d NAILS @ EA. TRUSS- 2x4 CONT. RIBBON W1 - (4) 16d NAILS @ EA. TRUSS 2x BLOCKING W/(2) -12d NAILS @ EA. END — 8d NAILS @ 24" O.C. TO BLOCKING — 2x STUDS SEE PLAN FOR INFO PLYWOOD 2x6 CONT. W/ (2)-12d NAILS @ EA. TRUSS CANTILEVER FLOOR TRUSS SEE PLAN 'IFTRUSS BRG. ONNECTOR AT EACH TRUSS, SEE PLAN LINTEL SEE PLAN L-STRUCTURAL SHEATHING CO�3 CANT. FLOOR TRUSS CONN_, I SCALE: 3/4" = 1 '-0" SCALE: Y4 0 z 0 -0 Z19 z u) a Z 4--J LU 0 0 LLJ E 0 V) yz(z 00 cNe) LU j,-- E — 8 0) ce) C W co E! 72 cco, 000 ii/W CLO < 0 CD 0 0 A I N.0 H.D C If — R D. LO Cn 1AZM 74d co MW 4W — I-- rL 'Llov, r UJI P, W 0 0 A. ?5 Z CP LL Q)A- 8 < N Ul CW11 8 6 Ffil tx� � El To the best of the Engineer's knowledge, Information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code Sth Edition (2014) Residential. Engineer's signature and seal Is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. 0 C) z 0 P-4 4-J C) V) C) p 4 -r N U-) M Lr) z OL- U — Ln L— LL zCL U fu CK CL 00 z 3i E z (0 LLj C) F- W tD g H 17 zL) ui 11 � 0- 10:-, 0 0 - z u 03 x dz� W. � R 6:1 0 Lr) < Cr z z 'a N LL Ln 0 > 0 0 V) —j LL LL 0 LU 8 18 -j rj 0 5181 LL4 ar < Z z Uj r-4 Ln < r-4 < z Lu 1-; co v- Z Z LLJ 0 z uj SCALE AS NOTED DATE 2/24/2014 TECH: FFLORES VERSION No' 10 SHEET NO. 7.0 �le, Z 01 TY 'KING DRY UPLIFT CONNECTION CROSS-REFERENCE MARK SIMPSON STRONG TIE USP MANUFACTURING, INC. 0 CONNECTOR CAPACITY FASTENERS CONNECTOR CAPACITY FASTENERS SYP SPF SYP SPF A HETA20 1810 9 - 10d x 1 1/2" HTA20 1615 1585 10 - 10d x 1 1/2" B HETA16 1810 9 - 10d x 1 1/2" HTA16 1615 1585 10 - 10d x 1 1/2" C H2.5A 600 535 10 - 8d RT7A 670 565 10 - 8d X 1 1/2" D H3 455 320 8 - 8d RT3 610 525 8 - 8d X 1 1/2" E META20 1450 7 - 10d x 1 1/2" HTA20-18 1400 1400 10 - 10d X 1 1/2" F HHETA20 2235 10 - 10d x 1 1/2" G H10A 1340 1015 18 - 1 Od x 1 1/2" RT16A 1380 1160 9-1 Od X 1 1/2"& 8-1 Od H HTT4 3610 3105 5/8"ANCH. /(18) 10dxl-112 HTT4 2715 518"ANCH. /(20) 1061-1/2 i HT75 4350 3740 5/8"ANCH./(26 10dxl-112' HTT5 3225 5/8' ANCH. 8) 10dxl-112 K HD313 3130 3050 5/8"DIA. BOLTS TDX2-TZ 2345 — 2 - 5/8" DIA. BOLTS L HD5B* 4505 3785 5/8" ANCH. 314" STUD BOLTS TDX6 5320 — 2 - 7/8" DIA. BOLTS M HD7B* 6645 5650 71F'ANCH. 314"STUD BOLTS TDX10 7845 — 4 - 7/8"DIA. BOLTS N LUS26 1165/1070 1005/915 § - 10d x 3" JUS26 1115/1060** — 8-10d P HUS25 1550/3335 1335/2820 20 - 16d x 3 1/2" HUS26 1925/3295 — (20)16d x 3-1/2" Q HUS28 2000/4220 1720/3125 30 - 16d x 3 1/2" HUS28 2570/4345 — 30d - 1 6d x 3-1/2" R MTS12 1000 860 14 - 10d x 1 1/2" MTW12 1195 1005 14-10d x 1-1/2" S MTS16 1000 860 14 - 1 Od x 1 1/2" MTW16 1195 1005 14-10d x 1-1/2" T MTS20 1000 860 14 - 10d x 1 1/2" MTW20 1 1195 1005 14-10d x 1-1/2" U MGT/MUGT 3140 3140 22 - 1 Od X (1) 5/8"ATR W/ 5" EMBED W/ SIMPSON "SET" EPDXY V LGT2 2150 1850 (1 6)16d SINKERS & (7) 1/4"x 2-1/4" TITENS LUGT2 1850 1810 (16)10d NAILS AND (5) 1/4" x 3" WEDGE BOLTS HXH HTS 20 1450 1245 24-1 Od X 1 1/2" HTW20 1530 1285 24-1 Od X 1 1/2" Spi 585 535 10 - 10d SPT22 685 8-10d SP2 1065 605 12 - 10d SPT24 1030 12 - 10d HCP2 1 6,45 5,55 12-1 Od X 1 1/2" MINIMUM 3"MEMBER REACTIONS ARE FOR ROOF LOADS ONLY DO NOT DRIVE NAILS THROUGH THE TRUSS PLATE ON THE OPPOSITE SIDE OF THE TRUSS, WHICH COULD FORCE THE PLATE OFF OF THE TRUSS. ALL EPDXY ANCHORS USP CIA-7000C NOTE: DOUBLE FELT REQ'D ON ROOF PITCHES 3/12 & LOWER. LOADS — ROOF = L / 360 FLOOR = L / 480 W/ 30MAX DEFLECTION. FLOOR JOIST SPACING SHALL BE MAX OF 19.2"OC FOR HARDWOOD & TILE AREA'S & 241, OC FOR CARPET AREA'S DROP HIP DETAIL, 2-0-0 MAXIUM SPACING ON VERTICALS OF (B) TRUSS A I I K\ — I I I �\\ (B) 11 1 1 1 1111 - (B) (A) A 11 1 1 1 11 11 10 11 11 11 1 1 (+ 11 11 1 N\ 11 I"\-10R2PLY CARRIER 1-8-8 CLEAR GAP BETWEEN (B) TRUSSES 6-) 'FASTEN EACH (B) TRUSS WEB TO EACH (A) TRUSS TOP CHORD @ EVERY INTERSECTING POINT SHOWN ON THE HIP TRUSS SYSTEM BELOW. FASTEN TOP CHORDS OF EACH (B) TRUSS TO THE TOP CHORDS OF (A) TRUSSES AT EVERY OTHER INTERSECTING POINT (B INTERSECTING POINT TO BE FASTENED WITH 2 - 16d COMMON NAILS OR 0. 128"x 3" GUN NAILS. FASTEN BOTTOM CHORD OF (B) TRUSS TO TOP CHORD OF CARRIER TRUSS WITH H THE SAME SPECIFIED COMMON NAILS OR GUN NAILS AT 48"OC. (+) IN LIEU OF PREFABRICATED HIP PLANING TRUSSES, (B) 2x4 SO. PINE #2 OR #2 PT. STICK LUMBER (LAID FLAT WISE) MAY BE USED. FOLLOW FASTENING SCHEDULE AS DEFINED FOR HIP PLANING TRUSSES. R1 STICK FRAMING SPLICING IS ALLOWED BETWEEN TRUSSES OR AT TRUSS [%1 0P 2 JOIV�)K�ER—J —(A) INTERSECTIONS. SPLICING x L TO BE STAGGERED BETWEEN COMMON TRUSSES, NO CATS REQUIRED UNDER STICK FRAMING SPLICING. MINIMUM LENGTH OF STICK FRAMING TO BE 6-13" ON A HORIZONTAL PROJECTION. NO TE: SEE SHEET D-1 FOR ROOF FRAMING DETAILS 1. (2) 12d TOENAILS EACH SIDE OF FLOOR TRUSS TO WALL OR BEAM BELOW TYP @ INT. BEARING U.N.O. SCALE: Y4`"=1'-0" i (D V0 z M 0 —01 z (D U) Z V) (D Q) U—) +-j LU U LU (D-V) 0f E 0 V) 00 r-- C14 LU E 8 Im C13 `­ 0 V) 2 "S co, 0.2 c, r 4i 6 LL 0 C> of < Lo 0 v ci A I ED. n c A a, §-04� E SAE AS z jf 0 0 g'4.0 F z IL e. 5 5 CA 01 N 0 El 1:1 To the best of the Engineer's knowledge, Information, and belief, the structural plans and specifications contained withi these drawings comply with the Florida Building Code 5th Edition (2014) Residential. Engineer's signature and sea] is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. CD 0 z (14 0 0) N 0-4 4.j C) U0 — 0 U-) M Lr) -0 z t2 1= a) —0 Ln L- LL F- C>L . 0 c1r) U z 00 z 3i E z LU C) -j C) W z g 0 480, or- I x - z u, :z Ln Cc: zi z 0 'D LL 4 D (0 Ln rr 0 > 0 0 U LL 0 0 < r*4 Z z Uj (1*4 Ln ul CY U- Uj X < < z z ?.� I wi-;0 z T-1 Z Z t-u LLJ 0 r�l :5 SCALE AS NOTED DATE 2/24/2014 TECH: FFLORES VERSION No' 10 SHEEr NO. 7.1 GENERAL INSTALLATION N TES 1 . Provide full mortar head and bed joints. 2. Shore filled lIntels as required. 3. Installation of lintel must comply with the architectural and/or structural drawings. 4, LI-LIntels are manufactured with 5-1/2" long notches at the ends to accommodate vertical cell reinforcing and grouting. 5. All lintels meet or exceed U360 vertical deflection, except lintels IT-4" and longer with a nominal height of 8" meet or exceed Ul 80. 6. Bottom field added rebar to be located at the bottom of the lintel cavity. 7. 7/32" diameter wire stirrups are welded to the bottom steel for mechanical anchorage. 8. Cast -in -place concrete may be provided in composite lintel In Ileu of concrete masonry units. 9. Safe load ratings based on rational design analysis per ACI 318 and ACI 530 10. Product Approvals: Miami Dade County, Florida Nos.03-0605.05 and 03-0605.04. 11. The exterior surface of lintels installed In exterior concrete masonry walls shall have a coating of stucco applied In accordance with ASTM C-926 or other approved coating. 12. Lintels loaded simultaneously with veritcal (gravity and uplift) and horizontal (lateral) loads shoud be checked for combine loading with the following equation: Applied vertical load + Applied horizontal load Safe vertical I Safe horizontal lo;-d- 0 GENERAL CONCRETE LINTEL SCHEDULE APPROVED LINTEL MANUFACTURERS: CASTE-CRETE, QUALITY 8F44 1 B/1 T 8F40 1 B/1 T 8RF40 OB/1 T 81`32 1 B/1 T elm 0 W AL M MEL= 0 I mom MEMO NUA Kamm _%�M 8F24-1B/1T T TYPE DESIGNAPON REBAR MIN. AT TOP (1) REQ'D ALTERNATE POWERS F = FILLED WITH GROUT / U = UNFILLED R RECESSED -112" CLEAR STEEL LINTEL — 4 4j 4 QTY. OF #5 — 0 REBAR @ BOTTOM OF LINTEL CAVITY 4 4 —,N*—C.M.U. #5 REBAR AT TOP — v MIN.(1)RECl'D_— 1-1/2" CLEAR i tj- EB/1 T 2 00 i�s 6 2 4 4 —GROUT QUANTITY OF tNOMINAL. t A -45 REBAR AT LO Lo -, En - I W, WIDTH #5 REBAR AT 0 BOTTOM OF a. 0 - lv�__ UJ 0 tn_ 01 TOP 0 "W LINTEL CAVITY Lu 5 08,7 Z_� Lu NOMINAL- -BOTTOM HEIGHT REINFORCING 0 M 7-5/8"ACT PROVIDED IN Z 0 LIJ a —#5 REBAR AT BOTTC 8"NOMINALWID LINTEL OS2 92 W 0 <1 �. N, AS INDICATED (VARIES) X (L 41 MATERIALS 1. rc prece tels = 3500 psi. 2. fc prestressed lintels = 6000 psi. 3. grouted per ASTM C476 fg = 3000 psi w/ 4. maximum &8" aggregate and 8" to 11" slump. 5. Concrete masonry units (CMU) per ASTM C90 wt minimum net area compressive strength = 1900 psi. 6. Reber per ASTM A615 Grade 60. Prestressing strand per ASTM A416 grade 7. 270 low relaxation. 7/32 wire per ASTM A510. B. Mortar per ASTM C270 type M or S. L�NTEL MINIMUM DEPTHS ARE CALLED OUT ON LINTEL PLAN. IF CONTRACTOR INSTALLS A DEEPER L NTEL THAN INDICATED ON THE PLAN, DOING THIS INCREASES THE STRENGTH OF THE LINTEL AND IS APPROVED WITHOUT ENGINEERING LETTER, IF A SMALLER LINTEL IS INSTALLED CONTACT E.O.R. FOR APPROVAL. (SEE LINTEL PLAN FOR SCHEDULE) 2x8 #2 SYP STUDS @ 8" O.C. W/ (2) USP MSTAM36 STRAPS EACH STUD ((1) STRAPS EACH SIDE) CENTERED W/ (113) 1 Od NAILS & (8) Y4" TITENS OR (2) 2x8 #2 SYP STUDS @ 16" O.C. W/ (4) USP MSTAM36 STRAPS ((2) STRAPS EACH SIDE) 2X8 #2 SYP P.T. BASE PLATE W/Y2" EPDXY ANCHOR OR Y2" J BOLT W/ MIN. 7" EMBEDMENT @ 32" O.C. & 6" FROM EACH END 16 GAUGE POWERS STEEL BOXED LINTEL POWERS STEEL BOXED LINTEL NOTES (ALT.) ONLY IF NOTED ON LINTEL PLAN 1. Refer to manufacturers specifications for Installation. 2. Contractor to provide proper protection of lintel to prevent rusting Refer to manufacturer's specifications. 3. If lintel is scratched or damaged refer to Powers Steel for repair. 4. Lintel depth to match precast depth. One #5 Bar required at top see lintel plarddetails for bottom steel required. 5. A bonding agent must be applied to the Steel Box lintels prior to applying the cementitluos coating. See contractor specifications STRUCTURAL SHEATHING ATTACHED PER NAILING SCHEDULE o,L SEE PLAN `F T/VVALL 8" KNOCKOUT COURSE W1 (1) #5 CONT. SEE PLAN FOR FILLED CELL SPACING WALL SPLICE DETAIL 1\� SCALE: 1" = 1'-0" 5'-10" LL �E 5'-8" LL (A) 5'-8" LL / 0A 171-40- LL (E) MIN. 5-8" LL OA LINTEL PLAN� SCALE: Y4"=V-0" (D LO Z —8 Zo ZCL V1 (D Z a) C-13 4--J Lu 0 U-i E Z:) C, 00 C) UJI E OEM C14 4) CI) CD M a 'a C, J! -0 - 0 *r_ C14 .20 S I0 LL Go 5 -oo M CL� < Cn in 0 t A I R 6C 3VL Z 5�� ZE .4 C9 LLJ U L A Z 0,00 t9 LLW Cj ....... 'will, To the best of the Engineer's knowledge, information, and belief, the structura I plans and specifications contained within these drawings comply with the Florida Building Code Sth Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. 0 Z 0 " 4-1 C:) U0 to U-) C (U —0 Ln U_ ce_ U Z < 00 Z E Z fu _j C:) W M F— 110 LU zoo �=u ZdLUX �2 Z� � 0 Lu U c1d Co Z Z 8 Ln Z H Z -a U-) > Lr) rq < 0 U V) _j LU �uj U_ g � 5 r- 6 rj LU 0 Z r-4 U, Ce ow Z LU 117114 Ln Lli Z � CY LL dFig < Q,�:) C8 2.� �i LU F� 8 Cal Z Z 0 rn 0- 1 V) I Lu SCALE AS NOTED DATE 2/24/2014 TECH: FLORES VERSION No' 10 SHEET NO. 8.0 - - I NOTE: BORATE APPLIED TO ALL FRAME MEMBERS WITHIN 24" A.F.F. 1) METHOD OF TREATMENT SHALL BE APPROVED BY THE GOVERNING JURISDICTION "LIQUID BORATE OR BOR-A-COR" PRODUCT METHODS MUST BE DETERMINED AT PERMIT STAGE. 2) PRESSURE TREATED LUMBER THAT HAS BEEN CUT OR DRILLED THAT EXPOSES UNTREATED PORTIONS OF WOOD ARE REQUIRED TO BE FIELD TREATED TO PREVENT INSECT INFESTATION. ATTENTION: CHEMICAL CHANGES IN PRESSURE TREATED WOODS AS OF DECEMBER 31ST, 2003, CHROMATED COPPER ARSENATE (CCA-C) WILL NO LONGER BE PRODUCED FOR RESIDENTIAL OR GENERAL CONSUMER USE. SEVERAL NEW PRESSURE TREATED WOOD ALTERNATIVES HAVE BEEN CREATED TO REPLACE CCA-C. MANY OF THE NEW PRESSURE TREATED WOODS USE CHEMICALS THAT ARE CORROSIVE TO STEEL. IT IS THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THE TYPE OF WOOD TREATMENT AND TO SELECT APPROPRIATE CONNECTORS THAT RESIST CORROSION. FOR EXAMPLE, ACQ-C, ACQ-D, CBA-A, OR CA-B REQUIRE HOT -DIPPED GALVANIZED OR STAINLESS STEEL FASTENERS. DOT SODIUM BORATE (SBX) DOES NOT. REQUIRED SAFETY GLAZING IN HAZARDOUS LOCATIONS (RE: FRC R308.4) R308.3 HUMAN IMPACT LOADS. INDIVIDUAL GLAZED AREAS INCLUDING GLASS MIRRORS IN HAZARDOUS LOCATIONS SUCH AS THOSE INDICATED AS DEFINED IN SECTION R308.4 SHALL PASS THE TEST REQUIREMENTS OF CPSC 16 CFR, PART 1201 CRITERIA FOR CATEGORY I OR CATEGORY 11 AS INDICATED IN TABLE R308.3 EXCEPTIONS: 1. POLISHED WIRED GLASS FOR USE IN FIRE DOORS AND OTHER FIRE RESISTANT LOCATIONS SHALL COMPANY WITH ANSI Z97.1 2. LOUVERED WINDOWS AND JALOUSIES SHALL COMPANY WITH SECTION R308.2 R308.4 HAZARDOUS LOCATIONS. THE FOLLOWING SHALL BE CONSIDERED SPECIFIC HAZARDOUS LOCATIONS FOR THE PURPOSE OF GLAZING: 1. GLAZING IN SWINGING DOORS EXCEPT JALOUSIES. 2. GLAZING IN FIXED AND SLIDING PANELS OF SLIDING DOOR ASSEMBLIES AND PANELS IN SLIDING AND BIFOLD CLOSET DOOR ASSEMBLIES. 3. GLAZING IN STORM DOORS. 4. GLAZING IN ALL UNFRAMED SWINGING DOORS. 5. GLAZING IN DOORS AND ENCLOSURES FOR HOT TUBS, WHIRLPOOLS, SAUNAS, STEAM ROOMS, BATHTUBS, AND SHOWERS. GLAZING IN ANY PART OF A BUILDING WALL ENCLOSING THESE COMPARTMENTS WHERE THE BOTTOM EXPOSED EDGE OF THE GLAZING IS LESS THAN 60 INCHES (1 524MM) MEASURED VERTICALLY ABOVE ANY STANDING OR WALKING SURFACE. 6. GLAZING, IN AN INDIVIDUAL FIXED OR OPERABLE PANEL ADJACENT TO A DOOR WHERE THE NEAREST VERTICAL EDGE IS WITHIN A 24-INCH(610MM) ARC OF THE DOOR IN A CLOSED POSITION AND WHOSE BOTTOM EDGE IS LESS THAN 60 INCHES (1524MM) ABOVE THE FLOOR OR WALKING SURFACE. 7. GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL, OTHER THAN THOSE LOCATIONS DESCRIBED IN ITEMS 5 AND 6 ABOVE, THAT MEETS ALL OF THE FOLLOWING CONDITIONS: 7.1 EXPOSED AREA OF AN INDIVIDUAL PANE GREATER THAN 9 SQUARE FEET (0.836 M2). 7.2 BOTTOM EDGE LESS THAN 18 INCHES (457 MM) ABOVE THE FLOOR. 7.3 TOP EDGE GREATER THAN 36 INCHES (914 MM) ABOVE THE FLOOR. 7.4 ONE OR MORE WALKING SURFACES WITHIN 36 INCHES (914 MM) HORIZONTALLY OF THE GLAZING. 8. ALL GLAZING IN RAILINGS REGARDLESS OF AN AREA OR HEIGHT ABOVE WALKING SURFACE. INCLUDED ARE STRUCTURAL BALUSTER PANELS AND NONSTRUCTURAL IN FILL -PANELS. 9. GLAZING IN WALLS AND FENCES ENCLOSING INDOOR AND OUTDOOR SWIMMING POOLS, HOT TUBS AND SPAS WHERE THE BOTTOM EDGE OF THE GLAZING IS LESS THAN 60 INCHES (1524 MM) ABOVE A WALKING SURFACE AND WITHIN 60 INCHES (1524 MM) HORIZONTALLY OF THE WATER'S EDGE. THIS SHALL APPLY TO SINGLE GLAZING AND ALL PANES IN MULTIPLE GLAZING. 10. GLAZING ADJACENT TO STAIRWAYS, LANDINGS, AND RAMPS WITHIN 36 INCHES (914 MM) HORIZONTALLY OF A WALKING SURFACE WHEN THE EXPOSED SURFACE OF THE GLASS IS LESS THAN 60 INCHES (1524 MM) ABOVE THE PLANE OF THE ADJACENT WALKING SURFACE. 11. GLAZING ADJACENT TO STAIRWAYS WITHIN 60 INCHES (1524 MM) HORIZONTALLY OF THE BOTTOM TREAD OF A STAIRWAY IN ANY DIRECTION WHEN THE EXPOSED SURFACE OF THE GLASS IS LESS THAN 60 INCHES (1524 MM) ABOVE THE NOSE OF THE TREAD. EXCEPTION: THE FOLLOWING PRODUCTS, MATERIALS AND USES ARE EXEMPT FROM THE ABOVE HAZARDOUS LOCATIONS: 1. OPENINGS IN DOORS THROUGH WHICH A 3-INCH(76 MM) SPHERE IS UNABLE TO PASS. 2. DECORATIVE GLASS IN ITEMS 1, 6 OR 7. 3. GLAZING IN SECTION R308.4, ITEM 6, WHEN THERE IS AN INTERVENING WALL OR OTHER PERMANENT BARRIER BETWEEN THE DOOR AND THE GLAZING. 4. GLAZING IN SECTION R 308.4, ITEM 6, IN WALLS PERPENDICULAR TO THE PLANE OF THE DOOR IN A CLOSED POSITION OR WHERE ACCESS THROUGH THE DOOR IS TO A CLOSET OR STORAGE AREA 3 FEET (914 MM) OR LESS IN DEPTH. GLAZING IN THESE APPLICATIONS SHALL COMPANY WITH SECTION R308.4, ITEM 7. 5. GLAZING IN SECTION R308.4, ITEMS 7 AND 10, WHEN A PROTECTIVE BAR IS INSTALLED ON THESE ACCESSIBLE SIDE(S) OF THE GLAZING 36 INCHES ± 2 INCHES (914 ± MM 51 MM) ABOVE THE FLOOR. THE BAR SHALL BE CAPABLE OF WITHSTANDING A HORIZONTAL LOAD OF 50 POUNDS PER LINEAR FOOT KG/M) WITHOUT CONTACTING THE GLASS AND BE A MINIMUM OF 1 X INCHES (38 MM) IN HEIGHT. 6. OUTBOARD PANES IN INSULATING GLASS UNITS AND OTHER MULTIPLE GLAZED PANELS IN SECTION R308.4, ITEM 7, WHEN THE BOTTOM EDGE OF THE GLASS IS 25 FEET (7620 MM) OR MORE ABOVE GRADE, A ROOF, WALKING SURFACES, OR OTHER HORIZONTAL [WITHIN 45 DEGREES (0.79 RAD) OF HORIZONTAL] SURFACE ADJACENT TO THE GLASS EXTERIOR. 7. LOUVERED WINDOWS AND JALOUSIES COMPLYING WITH THE REQUIREMENTS OF SECTION R308.2. 8. MIRRORS AND OTHER GLASS PANELS MOUNTED OR HUNG ON A SURFACE THAT PROVIDES A CONTINUOUS BACKING SUPPORT. 9. SAFETY GLAZING IN SECTION R308.4, ITEMS 10 AND 11 IS NOT REQUIRED WHERE: 9.1 THE SIDE OF STAIRWAY, LANDING OR RAMP HAS A GUARDRAIL OR HANDRAIL, INCLUDING BALUSTERS OR IN -FILL PANELS, COMPLYING WITH THE PREVISIONS OF SECTION 1012 AND 1607.7 OF THE FLORIDA BUILDING CODE, BUILDING; AND 9.2 THE PLANE OF THE GLASS IS GREATER THEN 18 INCHES (457 MM) FROM THE RAILING. 1. SPECIFICATIONS 1. 1. CONSTRUCTION: 1. 1. 1. ACI 318-11 BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE 1.1.2. ACI 530-11, ASCE 5/TMS 402-11 & ACI 530.1-11, ASCE 6/TMS 602-11 SPECIFICATIONS FOR MASONRY STRUCTURES. 1.1.3. ASTM C270-07a, C90-06b & C91-05 SPECIFICATIONS FOR MASONRY STRUCTURES 1.1.4. NATIONAL DESIGN SPECIFICATIONS (NDS) FOR WOOD CONSTRUCTION, 2012 EDITION, AND ALL ACCOMPANYING SUPPLEMENTS. 1.1.5. FLORIDA RESIDENTIAL CODE (FIRC), FLORIDA BUILDING CODE (FBC) 5th ad. (2014) 1.1.6. "MANUAL OF STEEL CONSTRUCTION, ALLOWABLE STRESS DESIGN", BY THE AMERICAN INSTITUTE OF STEEL CONSTRUCTION, (AISC) 13TH EDITION. 11. 1. 7. "DESIGN SPECIFICATION FOR LIGHT METAL PLATE CONNECTED WOOD TRUSSES" BY THE TRUSS PLATE INSTITUTE TRIII-02. 1.2. DESIGN: 1.2.1. ACI 301-11 BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE 1.2.2. ACI 530-11, ASCE 5/TMS 402-11 & ACI 530.1 -11, ASCE 6/TMS 602-11 SPECIFICATIONS FOR MASONRY STRUCTURES. 1.2.3. ASTIM C270-07a, C90-06b & C91-05 SPECIFICATIONS FOR MASONRY STRUCTURES 1.2.4. NATIONAL DESIGN SPECIFICATIONS (NDS) FOR WOOD CONSTRUCTION, 2012 EDITION, AND ALL ACCOMPANYING SUPPLEMENTS. 1.2.5. PLYWOOD DESIGN SPECIFICATIONS (APA) 1.2.6. FLORIDA BUILDING CODE (FBC) 5th ad. (2014) AND FLORIDA BUILDING CODE 5th ad. RESIDENTIAL (FBCR) 1.3. SHOP DRAWINGS: 1.3.1. THERE SHALL NOT BE ANY DEVIATIONS FROM THESE DESIGN PLANS BY OTHERS DURING THE PREPARATION OF SHOP DRAWINGS WITHOUT WRITTEN APPROVAL FROM THE ENGINEER OF RECORD. 1.3.2. ALL SHOP DRAWINGS ARE TO BE SUBMITTED TO THE ENGINEER OF RECORD PRIOR TO THE COMMENCEMENT OF CONSTRUCTION. 1.3.3. ALL ROOF AND FLOOR TRUSS SHOP DRAWINGS ARE TO BE SIGNED AND SEALED BY A FLA. REG. PE. AND SHALL INCLUDE: DRAWINGS AND CALCULATIONS, REACTIONS AND BEARING POINTS, BRACING REQUIREMENTS, AND CONNECTIONS TO SUPPORTING TRUSS MEMBERS. 2. DESIGN LOADS 2.1. DEAD LOADS: 2.1.1. UNIT WEIGHT OF SOIL, COMPACTED: 120 PCF 2.1.2. UNIT WEIGHT OF REINFORCED CONCRETE: 150 PCF 2.1.3. UNIT WEIGHT OF 8" C.M.U. BLOCK: 55 PSF 2.1.4. 1ST FLOOR SUPERIMPOSED LOAD: 20 PSF 2.1.5. UNIT WEIGHT OF 2x4 PARTITION WALLS: 11 PSF 2.1.6. UNIT WEIGHT OF 2x6 BEARING WALLS: 12 PSF 2.1.7. BALCONIES & DECKS: 15 PSF 2.1.8. TILE ROOF TOPCHORD: 15 PSF BOTTOM CHORD: 10 PSF 2.1.9. SHINGLE ROOF TOPCHORD: 7 PSF BOTTOM CHORD: 10 PSF 2.1.10. FLOOR TRUSSES 15 2.2. LIVE LOADS: 2.2.1. SIDEWALK AND DRIVEWAY LOAD: 250 PSF 2.2.2. GARAGELOADS: 40 PSF 2.2.3. PARTITIONED ROOMS: 40 PSF 2.2.4. BALCONY AND DECKS: 60 PSF-UNDER 100 sq. ft. 2.2.5. STAIRWAYS AND LANDINGS: 40 PSF 2.2.6. SLEEPING ROOMS: 30 PSF 2.2.7. FLOOR TRUSS TOP CHORD MINIMUM: 40 PSF 2.2.8. ROOFTRUSS TOP CHORD MINIMUM: 20 PSF BOTTOM CHORD (ATTIC W/O LIMITED STORAGE): 10 PSF (NON -CONCURRENT) BOTTOM CHORD (ATTIC W/ LIMITED STORAGE): 20 PSF 2.3. RAILING LOADS: 2.3.1. ALL RAILING AND GUARD RAIL SYSTEM'S ARE TO BE DESIGNED TO WITHSTAND A CONCENTRATED LOAD OF 200 POUNDS APPLIED AT ANY POINT AND IN ANY DIRECTION ON THE RAILING. 2.3.2. ALL RAILING AND GUARD RAIL SYSTEM'S ARE TO BE DESIGNED TO WITHSTAND A HORIZONTAL LOAD OF 50 PLF ON THE GUARDRAIL AND A SIMULTANEOUS LOAD OF 100 PLF APPLIED VERTICALLY DOWNWARD AT THE TOP OF THE GUARDRAIL 2.3.3. GUARDRAIL SYSTEM SHALL BE DESIGNED TO WITHSTAND 2001b CONCENTRATED HORIZONTAL LOAD APPLIED ON 1 SQ. FT. AT ANY POINT IN THE SYSTEM. 2.3.4. 2.3.1., 2.3.2 & 2.3.3. ARE NOT REQUIRED TO BE APPLIED SIMULTANEOUSLY, BUT EACH SHALL BE APPLIED TO PRODUCE THE MAXIMUM STRESSES IN THE MEMBER COMPONENTS. 2.4. WIND LOADS: 2.4.1. WIND DESIGN TO BE CONDUCTED IN ACCORDANCE WITH SECT. R301.2 OF THE FBC 5th ad, (2014), AND CONDUCTED BASED ON A140 MPH 3 SECOND GUST, EXPOSURE "C', IMPORTANCE FACTOR "I"= 1.0. ENCLOSED BUILDING 2.4.2. NET UPLIFT DEAD LOADS - 10 PSF SHINGLE, 15 PSF TILE 2.4.3. WIND LOAD DETERMINATION BASED ON ASCE 7-10 2.5. DEFLECTIONS: 2.6.1. FLOOR TRUSSES SHALL LIMIT DEFLECTION TO U480TIMES THE SPAN FOR LIVE LOADS AND U240 TIMES THE SPAN FOR TOTAL LOAD. 3. DESIGN METHOD 3.1. LOAD FACTOR DESIGN: THE LOAD FACTOR DESIGN METHOD WAS USED TO DESIGN: CAST -IN -PLACE CONCRETE SLABS AND FOOTINGS 3.2. SERVICE LOAD DESIGN: 3.2.1. THE SERVICE LOAD DESIGN METHOD WAS USED TO DESIGN: MASONRY WALLS AND LINTELS INTERIOR AND EXTERIOR WOOD FRAMING AND SHEATHING STAIRS AND FLOOR FRAMING ROOF FRAMING, SHEATHING AND UPLIFT 3.3. LOAD COMBINATIONS FOR LRFD DESIGNS: 3.3.1. THE FOLLOWING LOAD COMBINATIONS WERE DESIGNED FOR: TOTAL DIL + FLOOR LL + ROOF LL TOTAL DIL + FLOOR LL + WIL TOTAL DIL + WL 3.3.2. ALL ROOF AND FLOOR TRUSSES SHALL BE DESIGNED TO RESIST THE WORST LOAD COMBINATION RESULTING IN THE MAXIMUM STRESSES PLACED ON THAT COMPONENT. BOTH PARTIAL, FULL, AND ALTERNATING SPAN LOADING ARE TO BE CONSIDERED. 3.4. DESIGN ASSUMPTIONS: 3.4.1. ALL FOUNDATIONS ARE CENTERED UNDER SUPPORTED COLUMNS AND WALLS UNLESS SHOWN OTHERWISE IN THE DESIGN PLANS. 4. MATERIALS 4.1. REINFORCING STEEL: 4.1.1. REINFORCING STEEL SHALL BE ASTM A615 / A185M-04A MIN. GRADE 40, fy = 40 Ksi 4.1.2. LAP SPLICE SHALL BE AS FOLLOWS: #5 BAR 25", #4 BAR 20", #3 BAR 20". 4.1.3. ALL DIMENSIONS PERTAINING TO THE LOCATION OF REINFORCING ARE TO THE CIENTERILINE OF EACH BAR EXCEPT WHERE THE COVER DIMENSION IS SHOWN TO THE FACE OF THE CONCRETE. 4.1.4. REINFORCING DETAIL DIMENSIONS ARE OUT TO OUT OF BARS. 4.1.5. REINFORCING MECHANICAL COUPLERS ARE TO DEVELOP 125 % OF THE REQUIRED YIELD STRENGTH OF THE BAR AND ARE TO BE APPROVED BY THE ENGINEER OF RECORD. 4.1.6. DESIGN COVER REQUIREMENTS: C-I-P CONCRETE FORMED AGAINST EARTH: T' C-I-P CONCRETE EXPOSED TO EXTERIOR: 2- C-I-P CONCRETE NOT EXPOSED: 1 Y2" GROUT FILLED MASONRY: Y4 4.1.7. WELDED WIRE FABRIC (WWF): ASTM A-1 85 / A 185M-07 4.1.8. DETAIL REINFORCEMENT IN ACCORDANCE WITH ACI 318-11 (STRUCTURAL CONCRETE) ACI 530-11 (MASONRY STRUCTURES) 4.2. CONCRETE: 4.2.1. CONCRETIETYPE MIN. 28 DAY DESIGN (fC) MODULES OF ELASTICITY DESIGN (E) C-I-P CONCRETE (NORMAL WEIGHT) 2,500 Psi 2,850 Ksi C-I-P CONCRETE (NORMAL WEIGHT) HERNANDO CO. ONLY 3,000 Psi 3,122 Ksi C-l-P GROUT 3,000 Psi 3,122 Ksi 4.2.2. CONCRETE SHALL CONSIST OF 1" MAXIMUM AGGREGATE CONCRETE MIX WITH SLUMP BETWEEN 6"AND 7"AT TIME OF PLACEMENT. SEE SPECIFICATIONS FOR ADDITIONAL CRITERIA. 4.2.3. GROUT SHALL CONSIST OF PEA ROCK (3/8" MAXIMUM AGGREGATE) CONCRETE MIX WITH SLUMP BETWEEN 8"AND 10"AT TIME OF PLACEMENT. SEE SPECIFICATIONS FOR ADDITIONAL CRITERIA. 4.2.4. CONSTRUCTION JOINTS WILL BE PERMITTED 4.2.5. METHOD OF CONCRETE FORMING, PLACEMENT AND CURING SHALL BE CONDUCTED IN ACCORDANCE WITH THE SPECIFICATIONS AS STATED. 4.2.6. EARTH SUPPORTED SLABS (EXCLUDING EXTERIOR WALKWAYS & DRIVEWAYS): 31/2"MIN. THICKNESS W/ MIN. REINFORCEMENT OF 6.0 x 6.0 W/ 1.4 x 1.4 WWF @ MID -DEPTH OF SLAB, FIBER MESH PER DESIGN MIX MAY BE USED I.L.O. WWF @ CONTRACTORS DISCRETION. 4.2.7. CONCRETE PLACEMENT PRACTICES SHALL BE IN ACCORDANCE W1 ALL ACI- MCP 2011 STANDARDS. 4.3. CONCRETE MASONRY: 4.3.1. FILLED CELLS W/ (1) #5 BAR SHALL BE LOCATED PER PLAN. 4.3.2. LOAD BEARING CONCRETE MASONRY BLOCK SHALL BE ASTM C90-0601, TYPE 11 NON -MOISTURE CONTROLLED. 4.3.3. ALL CELLS & CAVITIES BELOW GRADE WILL BE FILLED W1 CONCRETE IN ALL STEM WALLS. 4.3.4. THE AGGREGATE STRENGTH OF THE BLOCK AND MORTAR SHALL BE F'm = 1,500 PSI MINIMUM. 4.3.5. METHOD OF CONCRETE MASONRY PLACEMENT AND CONSTRUCTION SHALL BE CONDUCTED IN ACCORDANCE WITH THE SPECIFICATIONS AS STATED. 4.3.6. MORTAR SHALL BE ASTM C270 TYPE "S" FOR ALL MASONRY CONSTRUCTION, 4.4. STRUCTURAL LUMBER: 4.4.1.1. INTERIOR LOAD BEARING -FALLS SPF #2, fb = 1,312 PSI, E = 1,400 KSI ALL EXTERIOR FRAMING SPF #2, fb = 1,312 PSI, E = 1,400 KSI 4.4.1.2. ALL FRAME WALLS TO BE CONSTRUCTED USING SPF #2, STUD QUALITY OR BETTER 4.4.2. ALL PLYWOOD USED FOR EXTERIOR APPLICATIONS SHALL BE APA RATED STRUCTURAL SHEATHING 15/32" EXP 1 OR 7/16" STRUCTURAL 1, U.N.O. 4.4.3. ALL PLYWOOD USED FOR INTERIOR APPLICATIONS SUCH AS SUB FLOORING AND SHEAR WALLS SHALL BE APA RATED SHEATHING EXP 1 U.N.O. 4.4.4. IF OSB BOARD IS TO BE USED IN PLACE OF PLYWOOD IS TO HAVE SIMILAR OR GREATER SECTION PROPERTIES. 4.4.5. ONLY STRUCTURAL LUMBER TO BE USED FOR AN EXTERIOR APPLICATION. WOOD IN CONTACT WITH CONCRETE IS TO RECEIVE A STANDARD GRADE PRESSURE TREATING. 4.4.6. WHEN PRE ENGINEERED TRUSSES ARE CALLED FOR ON THE PLANS THE MANUFACTURER IS TO SUBMIT SHOP DRAWINGS TO THE ENGINEER OF RECORD. 4.4.7. DESIGN, FABRICATE AND ERECT WOOD TRUSSES IN ACCORDANCE WITH THE 'DESIGN SPECIFICATION FOR LIGHT METAL PLATE CONNECTED WOOD TRUSSES" BY THE ANSIITPI 1-2007, BCSI 4.4.8. UNTREATED WOOD SHALL NOT BE IN DIRECT CONTACT WITH CONCRETE. SEAT PLATES SHALL BE PROVIDED AT BEARING LOCATIONS WITHOUT WOODEN TOP PLATES. 4.4.9. ALL EXTERIOR FRAME WALLS SHALL BE STUCCO FINISH- 7/8"STUCCO FINISH PER ASTM C. 926, APPLY 3 LAYERS W/ TOTAL THICKNESS 7/8' OVER METAL LATH. FIRST 2 LAYERS 3/8"THICK EACH. 3RD LAYER 1/8"THICK 4.4.10. INSTALLATION OF EXTERIOR LATHING & FRAMING SHALL COMPLY TO ASTM C 1063 PER FLORIDA CODE R706.6.1 4.5. FASTENERS AND TIE DOWNS: 4.5.1. FASTENERS AND TIE DOWNS SHALL CONSIST OF BUT ARE NOT LIMITED TO: SHAPES, ANGLES, CHANNELS: ASTIM A36136M 05 Fy = 36 Ksi ROUND METAL PIPE: ASTM A53, GRADE B Fy = 35 Ksi SQUARE METAL TUBING: ASTM A500, GRADE B Fy = 46Ksi HIGH STRENGTH BOLTS: ASTM A325 MACHINE BOLTS: GALVANIZED ASTIM A307 4.5,2. SHEET METAL ACCESSORIES SHALL CONFORM TO: Fy = 33KsWITH G90 GALVANIZED COATING IN ACCORDANCE WITH ASTIM A525-87. 4.5.3. NAILS SHALL CONSIST OF: COMMON WIRE NAILS WITH MINIMUM DIAMETER AS FOLLOWS: 8d = 0.131", 10d = 0.148", 12d = 0.148", 16d = 0.162". 4.5.4. ALL FASTENERS AND TIE DOWNS EMBEDDED IN CONCRETE OR USED IN AN EXTERIOR APPLICATION ARE TO RECEIVE AN ANTI -CORROSIVE COATING BY MANUFACTURER PRIOR TO INSTALLATION. 4.5.5. ALL FASTENERS AND TIE DOWNS ARE TO PROVIDE THE UPLIFT CAPACITY CALLED FOR IN THE PLANS ARE A MINIMUM. 4.5.6. ALL FASTENER TIE DOWNS, BEAM HANGERS, JOIST HANGERS, AND FLOOR TRUSS STRAPPING ARE TO BE INSTALLED IN ACCORDANCE WITH THE PLANS AND SPECIFICATIONS. 4.5.7. CONCRETE EMBEDDED'XBOLTS USED FOR UPLIFT ARE TO BE WET SET PRIOR TO INITIAL SET OF THE CONCRETE, SPACING AND ALIGNMENT ARE TO BE IN ACCORDANCE WITH THE DESIGN PLANS, U.N.O. ALTERNATES TO 7 BOLTS ARE NOTED ON PLANS. 4.5.8. CONCRETE EMBEDDED TIE DOWNS USED FOR TRUSS AND WALL UPLIFT ARE TO BE PLACED AROUND EMBEDDED REINFORCING PRIOR TO OR WHILE PLACING GROUT. 4.6. MICRO -LAM LUMBER: 4.6.1. MICRO -LAM STRESS GRADES SHALL PROVIDE THE FOLLOWING MINIMUM PROPERTIES: E 2,000,000 PSI Fb 2,950 PSI Ft 1,850 PSI Fc= 500 PSI (PERPENDICULAR) Fc = 2,700 (PARALLEL) 4.7. STEEL Fv = 285 PSI 4.7.1. INSTALLATION OF ALL STEEL TO BE PERFORMED BY AN EXPERIENCED, QUALIFIED STEEL ERECTOR. 4.7.2. FABRICATE AND ERECT ALL STRUCTURAL STEEL IN ACCORDANCE WITH A.I.S.C. "SPECIFICATION FOR THE DESIGN, FABRICATION, AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS". 4.7.3. STRUCTURAL STEEL: ASTM A36/36M 05. 4.7.4. STEEL TUBING: ASTIM A500, GRADE B. 4.7.5. WELDED CONNECTIONS: E70XX ELECTRODES, MINIMUM SIZE FILLET WELDS 3/16", AWS CERTIFIED WELDERS. CERTIFICATION PAPERS TO BE SUBMITTED UPON REQUEST. 4.7.6. WHERE STEEL BEAMS ARE CONTINUOUS OVER COLUMNS, PROVIDE WEB STIFFENER PLATES ON EACH SIDE OF THE WEB, OF A THICKNESS EQUAL TO BEAM FLANGE THICKNESS, LOCATED AT THE CENTER LINE OF THE TUBE COLUMN. 4.7.7. THE STEEL FRAME IS "NON -SELF SUPPORTING". ADEQUATE TEMPORARY SUPPORT SHALL BE PROVIDED BY THE CONTRACTOR UNTIL REQUIRED CONNECTIONS OR 4.8. SOIL: ELEMENTS ARE IN PLACE. 4.8.1. MINIMUM SOIL BEARING PRESSURE CAPACITY OF 2000 PSF. FOUNDATIONS HAVE BEEN DESIGNED WITH THE MIN. CAPACITY OF 2000 PSF 4.8.2. ALL SOIL IS TO BE CLEAN & POISONED FOR TERMITES PER FBC 5th ad. (2014), RESIDENTIAL SECTION R318. 4.8.3. SOIL IS TO BE COMPACTED TO 95% MODIFIED PROCTOR AS DEFINED BY ASTM D 1557-02EO1 TERMITE PROTECTION - CONTRACTOR TO USE (1) OF THE TREATMENTS BELOW Borate / Boracore treated lumber Soil Chemical Barrier Method Other treatment - Must specify proposed method and submit documentation, which substantiates the proposed method, is an approved termite protection system or method. OR CHEMICAL SOIL TERMITE TREATMENT IS USED 1 FIRC R31 4. 1 - "A permanent s� n which identifies the termite treatment provider and need for re -inspection a, treatment contract renewal shall be provided. The sign shall be posted near the water heater or electric panel" 2. Condensate and roof downspouts shall discharge at least V-0" away from the building side walls. 3. Irrimption/: yrinkler, aall risers and 0" of the building side wall. %stems includin sp y hea s shall n t be installed w hin 1' 4. FRC R318.7- To provide for inspechion for termite infestation, between wall covering and final earth grade shall not be less than 6 inches. Exception: Paint or decorative cementitious finish less than 5/8" thick adhered directly to the foundation wall. 5. FRC R318.1.1 - Initial treatment shall be done after all excavation and backfill is complete. 6. FRC R318.1.2 - Soil disturbed after the initial treatment shall be retreated including spaces boxed or formed. 7. FRC R318.1.3 - Boxed areas in concrete floors for sub stIc forMuent installation of traps etc., shall be made with permanent metal or pla Permanent forms must be of a size and depth that will eliminate the disturbance of soil after the initial treatment. 8. FRC R318.1.4 - Minimum 6 mil vapor retarder must be installed to protect against rainfall dilutipn. If r4infXII occurs before vapor retarder placement, retreatment is require . 9. FIRC R318.1.5 ;�Wegete overpour c _ ind mortar along the foundation perimeter must be remov ore exterior soi treatment. 10. FIRC R318.1.6 - Soil treatment must be applied under all exterior concrete or grade within V-0" of the structure sidewalls. 11. FRC R318.1.6 - An exteripr vertical chemical barrier must be installed after construction is complete, including landscaping and irrigation. Any soil disturbed after the vertical barrier is applied, shall be retreated, 12. FRC R318.1 - All buildings are required to have pre -construction treatment. 13. FIRC R318.1 - A certificate of compliance must be issued to the building department Rb , a licensed pest control company before a certificate of occupancy will be issued. e certificate of compliance shall state: 'The building has received a complete treatment for the prevention of subterranean termites. The treatment is in accordance with the rules and laws of the Florida Department of Agriculture and Consumer Services". 14. FIRC R318.6 - After all work is completed, loose wood and fill must be removed from below and within V-0" of the building. This includes all grade stakes, tub trap boxes, forms, shoring or other cellulose containing material. WORST CASE DESIGN PRESSURE TABLE BUILDING DATA WIND SPEED (ULTIMATE) 140 MPH WIND SPEED (ALLOWABLE) 108 MPH WIND EXPOSURE - "C" (FRC R301) INTERNAL PRESSURE COEFFICIENT= 0.18 ENCLOSED BLDG) BUILDING CATEGORY = 11 DESIGN WIND PRESSURE: (COMPONENT AND CLADDING) WORSTCASE (10 SF - END ZONE) # END ZONE IS ONLY WITHIN 6-0" OF ALL EXTERIOR BUILDING CORNERS WINDOWS AND DOORS 140 MPH + 29.7 PSF / -39.6 PSF (END) U.N.O. CONSTRUCTION + 29.7 PSF / -32.2 PSF (INTERIOR) U.N.O. TYPE: 513 GARAGE DOORS (V = 140 MPH) SINGLE 90 +26.3 PSF / -29.8 PSF DOUBLE 160 +25.2 PSF / -28.1 PSF NOTE: THE WIND PRESSURES LISTED ABOVE ARE ALLOWABLE PRESSURES. NOTE: IT IS THE CONTRACTORS RESPONSIBILITY TO REVIEW ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. FLORIDA DESIGN SOLUTIONS, INC. IS RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF THIS PROJECT ONLY. ANY DISCREPANCY BETWEEN FIELD CONDITIONS, OTHER DESIGN PROFESSIONALS' SHOP DRAWINGS, CONTRACTORS' BUILDING METHODS, AND THESE SIGNED AND SEALED DRAWINGS MUST BE BROUGHT TO THE ATTENTION OF FLORIDA DESIGN SOLUTIONS, INC. PRIOR TO THE COMMENCEMENT OF CONSTRUCTION. NOTE: GYPSUM BOARD MAY BE INSTALLED USING GWB54 NAILS TO SET IN PLACE. FIELD FASTENING SHOULD BE TYPE "W" 1)/4" DRYWALL SCREWS AT 12" O.C. FOR CEILINGS AND 1Y81, DRYWALL SCREWS AT 12" O.C. FOR WALLS. ALL ENDS AND EDGES OF WALLBAORD SHALL OCCUR OVER AND BE SCREWED TO SUPPORTS. MAXIMUM SCREW SPACING AT ENDS (EDGES IN VERTICAL APPLICATION) SHALL BE 6" O.C. AT EACH SUPPORT. MINIMUM SCREW NAIL DISTANCEFROM EDGE SHALL BE Y8". THIS SHALL APPLY TO BOTH CEILING AND WALL INSTALLATION. DRYWALL SHIMS SHALL BE USED ONLY WHERE NECESSARY. OPENINGS CUT FOR OUTLETS, SWITCHES, ETC, SHALL BE OF A TOLERANCE THAT CAN BE COVERED ADEQUATELY WITH NORMAL SWITCH PLATES AND COVERS WITHOUT ADDITIONAL TAPING OR CAULKING. DRYWALL SHALL NOT BE INSTALLED WITHOUT PROPER BACKING. NOTE: ALL HEADERS, BEAMS, ETC ARE TO BE SYP #2 OR BETTER AND OR MICROLAM AS INDICATED ON THE DRAWINGS AND CAN NOT BE REVISED. (D z co z CID z Z V) (D Q) V-) 4--d LU U L1.1 0 0:f V) :D E 0 V) U) cr) V LU E 8 no( CN IS I M c"? E! 'S cc,14 0.20 9 :5 LL Co 3100 0 M i:z 05 'CL < 0 < 6 A I D. N. C' . D If I T, w4L e-c5 R- W;� ci tL .0., (n 1,6 Cl) .W LLI LLJ > .< am- , 0 W2 LLZ W R air C? 0 1:1 IJ To the best of the Engineer's knowledge, Information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code Sth Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. C=) 0 z 0 4-P C=) Ln M LI) (D Ln z a) !e Ln h- U_ 31% M z CL 00 Z E z M LU _j 0 W %-0 cdo P400 00�0 Q U., � Wz 9 _j I LIU I U) LLJ M!ja F- tX z Ln 0 < z Z 1 z 0 -a z T Ln 0 > Z:) UI I -0 0 P C/) < z r*4 i�auj� z r4 Ln < < z z Z LU 0 rn v-4 :5 a. X: I V) SCALE AS NOTED DATE 2/24/2014 TECH: FFLORES VERSION NO' 10 SHEET NO. SN CORNER OF HOME GARAGE SIDE ROOF DIAPHRAGM NAILING SCHEDULE RIDGE LINE + + + + + t- + 4- + + + + + + + + + + + + + + + �- + + 4+- + + + + + + + . . . . . . . . . . . . . . + + + + + + + + + + + + + 4 + 4 + + + + + + + + + + + 4 + + + + + + + + + + + + . . . . . . + + * + + + + 1-01, (TYP.) + + 64' 6-4- + * + + + + + + + + + + + + ­1 _++ UJ + + 1 15/32" CDX _J + + co + 4 + + PLYWOOD OR + + + 7/16" OSB + + + + + + 4' + + 4 + + + + + + + + + + + + + + + + + + + + + 4- + + + + + + �4+ + .1 + + + + + + + . . . . . . + + + + + + , - , /+� ++ + + 4K+++' + + 4 4- 4 if + I \-RIDGE LINE 140 MPH (1.1103 SECOND GUST EXPOSURE "C" WIND ZONE 140 MPH ON 3 SECOND GUST EXPOSURE "C" WIND ZONE 8d RING SHANK NAILS @ 6" O.C. & 8d RING SHANK NAILS @ 6" O.C. EDGES & 4" O.C. @ GABLE END WALL OR GABLE TRUSS 8d RING SHANK NAILS @ 6" O.C. INTERMEDIATE 0. 113 INCH NOMINAL SHANK DIAMETER 0.113 INCH NOMINAL SHANK DIAMETER RING DIAMETER OF 0.012 OVER SHANK DIAMETER RING DIAMETER OF 0.012 OVER SHANK DIAMETER 16 TO 20 RINGS PER INCH 16 TO 20 RINGS PER INCH 0.280 INCH FULL ROUND HEAD DIAMETER 0.280 INCH FULL ROUND HEAD DIAMETER 2 INCH NAIL LENGTH 2 INCH NAIL LENGTH NOTE: r FOR8d RING SHANK NAILS 0.1 13x 2x 3/8" RING SHANK COIL GUN NAILSMAYBEUSED 1) SEE STRUCTURAL NOTES FOR SHEATHING SPECIFICATIONS AND WIND SPEED. 2) END JOINTS OF THE ROOF SHEATHING SHALL BE STAGGERED AND OCCUR OVER FRAMING MEMBER. 3) SCHEDULE ASSUMES SHEATHING IS FASTENED DIRECTLY TO SOUTHERN YELLOW PINE OR DOUGLAS FIR OR BETTER. IF ROOF FRAMING CONSISTS OF A LESSER GRADE OF LUMBER, CONTRACTOR MUST CONTACT ENGINEER OF RECORD FOR ALTERNATE NAILING PATTERN, Backer and Filler Block Dimensions BCIaJoist BackerBlock Thickness Filler Block Thickness Series 3/4" or 7/8" 5000s 1.8/1.7 wood panels Two 3/4" wood panels or 2 x 1-1/8" or two 1/2" 6000s 1.811.7 wood panels 2 x + 5/8" or 3/4" wood panel 1-1/8" or two 1/2" 6500s 1.8/1.7 wood panels 2 x + 5/8" or 3/4" wood panel 1-1 /8" or two 1/2" 602.0 wood panels 2 x + 5/8" or 3/4" wood panel 902.0 2 x lumber Double 2 x lumber DOUBLE JOIST CONSTRUCTION (Not required if both loaded equally from above) Filler blocking 1/8" gap FILL CELL cr_ _-<. STD. 900 CONT. #5 HOOK BAR STD. 900 HOOK BOND BEAM USP �S_ CONT. #5 ZT15:�P�, GIRDER TRUSS BAR 2X TOP PLATE #5 CONT. 5/81 THRU BOLT FROM FOUNDATION TO HIGHEST BOND BEAM y BOND BEAM STEP SCALE: N.T.S. ,--2nd FLOOR INTERIOR/EXT WALL SEE PLAN FOR MORE INFO CONT. BASE PLATE BEARING COLUMN PLYWOOD FLOOR SEE PLAN FOR REQ'D COLUMN AND SHEATHING PER PLAN CONNECTION TJI TO BE CUT TO ALLOW FOR BLOCKING/TJI < WALL OR INTERIOR BRG. WALL TJI PER PLAN OTHERWISE SOLID BLOCKING TO MATCH # OF 2nd FLOOR Solid block all posts from above to bearing below. STUDS SECTION @ INT. BRIG. WALL N.T.S. 1/8" min. Small gap 2" min. 2" max. 1 4" max. F- Web-St-iffen _-P—astenerSchedule _ff er Joist B ring ocation Series � DepLh --End Intermediate >1 A 9-1/2" 2-8d 2-8d BCI 5000sP_f1__-7/8" -8d 3-8d --5-8d- 14" 2-8d Clinch nails 9-_1/2� 2-8d 2-8d when K � BCI 6000se-1 1-7/8" 2-8d 3-8d possible BCI 6500s""-14" 2-8d I— 5-8d -16" 2-8d 4\ 6-8d I 1) Support back of web during nailing to prevent damage to web -flange connection. - 11-7/8" @ �- ��i 60S v 14" 2-8d 2-8d 3-8d 6-6d­__ 2) Block solid between joists for full length of span. Tigh t fit ------------ �BCI 1 16—" 2-8- _d --6-8d- 3) Leave 1/8" gap between top of filler blocking and bottom of top flange. 4) Place joists together and nail from each side with 2 rows of 1 Od nails 2x4/Plywood/OSB web sti ener 2" min. 4" FU-7/8" BCI 90s@ 14" 3-16d 5- _-16d I 3-16d I— 5-16d required when indicated or max. 16" 6-16d 6-16d 2x-: CONTRACTOR TO PROVIDE 2x TO FILL THE HEIGHT at 12" o.c., clinched when possible. Stagger rows from opposite - Hangers with side nailing. OF THE JOIST ASA REQUIRED LEAVING Y8" GAP @ TOP sides by 6". - Hangers with sides not containing top flange of joist. WEB STIFFENER - Birdsmouth cuts. N.T.S. DOUBLE JOIST CONNECTION - Under 2nd floor column w/ loads N.T.S. hi her than 15001b SQUASH BLOCKS AT INTERIOR BEARING Vertical load transfer =1 900 plf max along load bearing wall. Load bearing wall must stack over squash=20 blocks and *Non -stacking walls wall or beam below.* require additional consideration. Check local building code for appropriate --- 11/16" details in One 10d box areas=20 of high or--20 sinker lateral load. nail each side 101-011 at bearing. TANK -LESS W/H 0 1 0'_0 TANK -LESS W/H H C G 000 51-0-1 0 STUB-0( IT FOR­__#� 11-011 & 9 -1 CD GAS METER 0 t---, 01 0 U') N MEASUREMENTS ARE FROM FINISHED FLOOR ROUGH -IN GAS TO RIGHT (ALWAYS) - 12" OFF -CENTER ROUGH -IN ELECTRIC TO LEFT (ALWAYS) - 12" OFF -CENTER GAS CONNECTION DETAIL "ONLY APPLIES TO HILLSBOROUGH AND PASCO COUNTY** RAFTER SPAN TABLE MEMBER SIZE AND SPACING MAXIMUM LENGTH MEMBER CONNECTIONS* 2" X 4" @ 16" O.C. 71-511 (2) 16d TOENAILS 2" X 6" @ 16" O.C. 10'-8" (2) 16d TOENAILS 2" X 8" @ 16" O.C. 13'-911 (3) 16d TOENAILS 2" X 10" @ 16" O.C. 161-5" (1) USP HTW20 OR (3) 16d TOENAILS 2" X 12" @ 16" O.C. 19'-3" (1) USP HTW20 OR (4) 16d TOENAILS 2" X 4" @ 24" O.C. 6--l" (2) 16d TOENAILS 2" X 6" @ 24" O.C. 81-6" (2) 16d TOENAILS 2" X 8" @ 24" O.C. 111-001 (2) 16d TOENAILS 2" X 10" @ 24" O.C. 'IT-01t (3) 16d TOENAILS 2" X 12" @ 24" O.C. 15t-4" (1) USP HTW20 OR (3) 16d TOENAILS TOENAIL CONNECTIONS 'DESIGNED FOR SHEAR ONLY (i.e. RAFTER TO RIDGEBEAM). SOUTHERN YELLOW PINE, 55 PSF LOADING Squash block (2x4 minimum) Bearing wall, Versa -Lam LVL or Glularn Beam Boise Joist Blocking Use T' (10dl nails at 6" nx_-� Provide adequate bearing for each lapped joist. Od nails SECTION @ INT. BRIG. WALL N.T.S. MINIMUM SPACING 2x GREATEST KNOCKOUTS) ALLOWED DIMENSION OF LARGEST HOLE IN BEARING ZONES D NOCKOUTEXEMPTS) (se, (see table below) D (see table below) DO NOT cut, notch 2K or drill flanges . BLOCKING PANEL, INTERIOR Vertical load transfer =1 900 pff max. along bearing wall Required on interior walls for vertical load transfer Plumbing when load bearing - for lateral support when joists meet over wall, or wall stacks directly over wall or beam below Load bearing wall must stack over blocking and wall or beam below.* Joist When joists meet over wall, provide 1-13/4" minimum bearing for each. I -Joist can be offset " Pit Use 1 Odx3" nails at 6"o.c. for all joist blocking panel *Non -stacking walls require additional consideration. 4X k1100- --- ____ 6"' A %" ROUND HOLEMAY 610 6" -DO NOT CUT HOLES BE CUT ANYWHERE IN 7= THE WEB. PROVIDE AT CANTILEVER LARGER THAN ROUND IN LEAST 3" OF CLEARANCE CANTILEVERS. FROM OTHER HOLES MINIMUM DISTANCE FROM SUPPORT, LISTED BELOW, IS REQUIRED FOR ALL HOLED GREATER THAN ly2" NOTES: 1. JOISTS MUST BE PROPERLY DESIGNED TO MEET BUILDING CODE REQUIREMENTS. 2. TABLE IS FOR UNIFORMLY LOADED MAXIMUM LOADS OF 40 PSL(LIVE) AND 15 PSF (DEAD) ON SIMPLE SPAN APPLICATIONS ONLY. 3. REFER TO JOIST SPECIFIER GUIDE FOR INSTALLATION AND OTHER INFO. 4. SELECT A TABLE ROW BASED ON JOIST DEPTH AND THE ACTUAL JOIST SPAN ROUNDED UP TO THE NEAREST TABLE SPAN. SCAN ACROSS THE ROW TO THE COLUMN HEADED BY THE APPROPRIATE ROUND HOLE DIAMETER OR RECTANGULAR HOLE SIDE. USE THE LONGEST SIDE OF A RECTANGULAR HOLE. THE TABLE VALUES IS THE CLOSEST THAT THE CENTERLINE OF THE NEAREST SUPPORT. 5. THE ENTIRE WEB MAY BE CUT OUT. DO NOT CUT THE FLANGES. HOLES APPLY TO EITHER SINGLE OR MULTIPLE JOISTS IN REPETITIVE MEMBER CONDITIONS. 6. FOR MULTIPLE HOLES, THE AMOUNT OF UNCUT WEB BETWEEN HOLES MUST EQUAL AT LEAST TWICE THE DIAMETER (OR LONGEST SIDE) OF THE LARGEST HOLE. 7. %" ROUND KNOCKOUTS IN THE WEB MAY BE REMOVED BY USING A SHORT PIECE OF METAL PIPE AND HAMMER. 8. HOLES MAY BE POSITIONED VERTICALLY ANYWHERE IN THE WEB. THE JOIST MAY BE SET WITH THE %" KNOCKOUT HOLES TURNED WITHER UP OR DOWN. 9. THIS TABLE WAS DESIGNED TO APPLY TO THE DESIGN TO APPLY TO THE DESIGN CONDITIONS COVERED BY TABLES ELSEWHERE IN HIS PUBLICATION. USE THE BC CALC SOFTWARE TO CHECK OTHER HOLE SIZES OR HOLES UNDER OTHER DESIGN CONDITIONS. IT MAY BE POSSIBLE TO EXCEED THE LIMITATIONS OF THIS TABLE BY ANALYZING A SPECIFIC APPLICATION WITH THE BC CALC SOFTWARE. HOLE CUTTING CHART N.T.S. up to 3 to avoid vertical plumbing 3" max JOISTS OFFSET N.T.S A 1,C U ML TYPICAL USP MUGT15 TO BUILT-UP COLUMN DETAIL TYPICAL HUS INSTALLATION MIN. EMBEDMENT SCHEDULE FOR AND QUANTITY )F FASTENERS TYPICAL HTA 20-18 HTA 20 INSTALLATION A/C CHASE 4" PVC SLEEVE THRU STEM WALL Backer block (12" wide min.) Nail with 10- 10d nails. Install tight to top flange. EVE THRU TEM EE PLANIFOR 0 U TI 7" SLEEVE THRU STEM 6— "Z 'a SEE PLAN FOR FOUNDATION INFO STEM FOUNDATION Fillerblock. Nail with 10-10d nails. Backer block required where top mount hanger load exceeds 250 lbs. Install fight to top flange. A - k1/4"-2" gap F � Backer Block,----) "Top Mount" "Face Mount" Backer block shall be tight Backer block shall be fight to bottom of top flange with to top of bottom flange with 1/4"-2" gap at top of bottom 1/4"-2" gap at bottom of top flange. flange. Web stiffeners are not required when top /!e 'ffner as , 'b s' f r uired I hanger flange is laterally supported by joist hanger. doesn't meet height r. 7 requirements I 0 6 X Joist epth d I -JOISTS BUCKETS N.T.S. ell; r 4 la I 11 1"1 -14 r=-,m il a goll. 1 g ;1R I I -6-RANA (2) #5 REBAR A/C CHASE 4" PVC SLEEVE THRU FOOTING MONO FOUNDATION TYP. FND. PENETRATIONS SCALE: N.T.S. HTA 20-18 HTA 20 INSTALLATION @ MID SPAN LOCATION OF SECOND RT16 NOTE: UPLIFT VALUE IS BASED ON S.P.F. USP RT16 USING 16-8d A 1/2" NAILS UPLIFT 1030# TYPICAL RT16 INSTALLATION TYPICAL MTW INSTALLATION TOP (2) #5's x 4'-0" CENETERED @ PIPE PENETRATION PLUMBING LINE PVC OR SCH40 SLEEVE A I ""I 1�1 I r-k 1� PVC OR SCH40 SLEEVE TOP (2) #5's x 4'-0" CENETER PENETRATION E ED @ PIPE PLUMBING LIN 41 'A . .4 SEE FND. PLN. SIZE & REINF. PIPE PERPENDICULAR TO FND. TOP (2) #5's x 4'-0" CENETERED @ PIPE PENETRATION A PVC OR SCH40 SLEEVE PLUMBING LINE 4 . 4V A SEE FND. PLN SIZE & REINF. r- z Cl) - 8 z z < I CL U) z un (D LLI 0 U — LU 0 *1 V) r_ =:) ED- 0 � V) 2 CD Fn r-- 04 0) ce) U-1 E 8 as 0) M W V) 72 co, 0 Z5 C, m: 4i (.) % :S LL 00 3 6 a CL 0 < L N C B D C -o ODO At c" .0 __J _J $z 21r 0 co W-3 CL FUJ < F 3; 8g z , 1 --" W C14 00 0 0 M 110 El To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code Sth Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. 4 C:) 0 z " 0 (U N F-4 J.J C) :3 %D M C) 0 4-0 U-) M Ln z 2: 0 L LL CL >� � CY) U M -I CL 00 z E LU C:) _J 0 W '0 mi z g Uz. !� z Lu U Ix z: EYE U) LL1 i,- UJ Ln 0 z 0 ­0 N 2: 2: 2 W Ln _J <L E 0 U > U-) M LU tj 0 _J zW r14 0 Z U4 ar=1 z z LU f**4 r*4 Ln 6i 2 IINE� 11�,:) I 1LU < z < LU i..; 91 r_J CID z Z :5 ILIJ Fz 0 9 0 r_% 1-4 CL V) SCALE AS NOTED DATE 2/24/2014 TECH: FFLORES VERSION N 0' 10 SHEET NO. SN 1 (1) ROW 2x BLOCKING @ MID 2x #2 SPF STUDS HGT. FOR WALL HGT. 15 V-16". (2) @ 16" O.C. W/ (2) ROWS 2x BLOCKING @ 3rd PTS 16dTOENAILST&B FOR WALL HGT. > 8'-6". 1/2" GYP. WB (MIN.) @ GARAGE SIDE IF ;2� APPLICABLE. 2x P.T. PLATE 1/4" DIA. X 3 1/4" TAPCONS @ 2411 O/C & ci @ 6" MAX FROM END OF 2 x PLATE E (1) LAYER TYPE 11 (#30) (2) #5 CONT. ON 3" 6 x 6 W1.4 x W1.4 UNDERLAYMENT FOR ROOF CHAIRS (TYP.) WWF OR FIBERMESH PITCH >4:12 V (2) LAYERS TYPE I OR TYPE 11 (#15 OR #30) UNDERLAYMENT t> FOR UNDERILAYMENT FOR ROOF PITCH 4:12 OR LESS. REQUIREMENTS SEE R905. PRE ENGINEERED WOOD I TRUSS @ 24" O.C. U.N.O. :�j 12 ANCHOR @ EACH TYP') VARIES //--HURRICANE TRUSS (SEE UPLIFT SCHED.) W/ 8" METAL PL. UNDER EA. TRUSS MOISTURE BARRIER TYPICAL INTERIOR BEARING INSULArION LE SHINGLE ROOF 7116" O.S.B. MIN. SEE ROOF WALL W/OUT UPLIFT rG G NAILING SCHEDULE ON SHT. SEE TYP. WALL SECTION SCALE: 3/4"=V-0" SN1 ELEV. VARIES FOR ADDITIONAL SLAB INFORMATION. 5/8" OR 1/2" HIGH ALUMINUM DRIP STRENGTH CEILING EDGE 5/8"OR 1/2" HIGH STRENGTH TRUSS BOTTOM CHORD OR 2x4 BLOCKING 5/8"OR 1/2" HIGH STRENGTH (U.N.O.) (OR %" GYP. TYPE "X" @ W/ 2-16d TOE NAILS @ EACH END GARAGE W/A HABITABLE ROOM 0 (U.N.O.) (OR %" GYP. TYPE ")C@ ABOVE) )!/,,j[vSEE UPLIFT SCHEDULE FOR UPLIFT GARAGE W/A HABITABLE ROOM S.P.F. DOUBLE CONNECTIONS. PROVIDE (1) USP HTW20 WHEN ABOVE) TOP PLATE TRUSS ALIGNED WITH STUD BELOW S.P.F. DOUBLE 8"x8"x1 6" NOMINAL BLOCK WITH TOP PLATE 3/8" MORTAR BETWEEN COURSES USP SPT24 T CONNECTOR CONNECTOR 2"x S.P.F. (OR EQUAL) STUDS @ 16" O.C. U.N.O. USP SPT24 1/2" CDX PLYWOOD OR 7/16" O.S.B. SHEATHING REQ'D. FOR ALL 1) ROW 2x BLOCKING @ MID HGT. FOR WALL INDICATED ON THE PLAN. ATTACH FOR WALL HGT. > 8'-1 EXTERIOR OR SHEAR WALLS AS HGT. < 8'-6". (2) ROWS 2x BLOCKING @ 3rd PTS SHEATHING W/ 8d COMMON NAILS @ INSULATION PER CHART ON FLOOR PLAN I` rF 4" O.C. @ BOUNDARIES, 6" O.C. @ I 3/8" MORTAR BETWEEN EDGES, AND @ 12" O.C. @ FIELD SLAB & BLOCK 5/8" x 10" "J" BOLT @ 24' O.C. W/ SP SPT22 CONNECTOR 5t 2"'x3/16" PLATE WASHER (TYP.) (A ELEV. U-0.1 (ALT: 1/2"x`12" TITEN HD @ 24" 2x P.T. BOTTOM PLATE 0. AK — O.C. OR 5/8"x10'WEDGE ANCHOR P x 6 W1.4 x W1.4 A. F. F. %`w @ 24" O.C.) 21- WWF OR FIBERMESH @ 0 3 1/2" MIN. 4 4 ELEV. 4-3 1/2" z 4 4 P: 1 A. 0 4 2x4 CO t_j . LL 4 NT�/ 4 � z 2� 1/2"(min.) CD CNI ;0 ;0 4 4 4-1 4 4 GARAGE DEPTH VARIES 4 (2) #5 CONT79 4" 11 V-4" 8.1 U.N.O. MIN. GARAGE SLAB AT STEP B� TYPICAL BEARING WALL C@ STEP C@ SHEARWALL SCALE: 3/4"=V-01" S3 �) "SHEAR WALL" SCALE: 3/4"=V-101" 0_1 TRUSS BOTTOM CHORD OR 2x4 BLOCKING W/ 2-16d TOE NAILS @ EACH END SEE UPLIFT SCHEDULE FOR UPLIFT CONNECTIONS, PROVIDE (1) USP HTW20 WHEN TRUSS ALIGNED WITH STUD BELOW —2"x S.P.F. (OR EQUAL) STUDS @ 16" O.C. U.N.O. FOR )CKING I PLAN DV/Ar%LJ rEJA t_,VIJC kUr-, 010 ALUMINUM FASCIA 1/2" OR 7/16" OSB MIN. PLYWOOD SHEATHING CIS. GYP. TYPE "X" @ GARAGE L \12' NAILED W/ 8d COMMON NAILS @ 4" O/C W/A HABITABLE ROOM N.O\, 2x SUB FASCIA 2x S.P.F. S S 16" O.C. BOUNDARIES, 6" O/C EDGES, AND 12" O/C FIELD. ABOVE) W/DRYWALL EE SOFFIT A — 2x STUD SHEAR WALL REQUIRES 2x BLOCKING @ SEAMS. 00� SCREWS @ 7 O.C. SHE ET ­4 LOADBEARINGOR (1) ROW2X BLOCKING@ MID HGT. CEILING & 8" O.C. WALLS EXTERIOR WALL 81, C ' M.U. (2) ROWS OF 2x BLOCKING @ 2x STUDS @ 16" O/C NOTE: FOR WALL HGT. --q V-113". (2) INSULATION PER X8 "X16" KNOCK -OUT BLOCK W/ 1#5 CONT. 1"xPT STUD THIRD POINTS ULATION PER CHART ON FLOOR PLAN SEE SECTION C/S3 FOR ROWS 2x BLOCKING @ 3rd PTS FOR WALL HGT. > 8'-6". CHART ON FLOOR FILLED SOLID W/GROUT #5 VERT. IN FILLED CELL 7/8" STUCCO FINISH PER ASTM C. 926 APPLY 3 ADDITIONAL INFORMATION PLAN SEE CC/S3 OR LAYERS W/ TOTAL THICKNESS 7/8" OVER 1/2" GYP. WB (MIN.) @ GARAGE 1x2 P.T. HORIZONTAL G/S3 FOR ANCHOR "J" 5/8" x 10" "J" BOLT @ 24- O/C W1 2"'X 3/16" METAL LATH. FIRST 2 LAYERS 3/8" THICK EACH, CONTINUOUS TO FOOTER BELOW 90 HOOK DETAIL USP SPT22 CONNECTOR SIDE IF APPLICABLE. NAILER 8" C.M.U. TYPICAL BOLT INFO. 5/8"4" BOLTS BOLT PLATE WASHER TYPICAL 3RD LAYER 1/8" THICK. @ K.O. BLOCK 5/8"- EXPANSION BOLT @24 " O.C. STD. 90-HOOK (SEE DETAIL) TYPE "S" MORTAR (IF NO UP LIFT ON @ 24" O.C. VERT. OR 5/8" x 6" EPDXY BOLT OR WALL SEE GG/S3) 444 (6 1/4" : x3 1/4" TAPCONS SP SPT22 @ EA. STUD MIN. 2500 PSI CONCRETE SLAB W/ 6 x 6 W1.4 x W1.4 WWF OR X P.T. PLATE 20- MIN, LAP [24- MIN. LAP] r nr1k1ff^rjf1 2x P.T. PLATE W/ 7' - EMBEDMENT (MIN. SHEAR SPACE ANCH R 3500#, MIN. TENSION 2601 11 A — 1A11 A E FIBERMESH Ar; BAR o 2x P.T. PLATE N%-#3 OR #4 REINFORCING BAR ARCHITECTURAL ASSUMED FINISHED Owl FINISH E GRADE 40 MIN. Fy= 40ks'l 4 1x2 PT WD FURRING @ 24" O.C.-/ Mimi �GRADE #3 & #4 LAP SPLICE [GRADE 60 MIN. Fy= 60ksi] FINISH GRADE 00 25" MIN. LAP [30- MIN. LAP) (1) #5 VERT. IN FILL MONO OR STEMWALL---,, 1/2" GYPSUM WALLBOARD ­�- - Z - 11� N, F CELLS(SEE .1 .. L 1-111 -0 1" -_ _% U.N.O. FOOTING MONO SHOW go Affiff I AA I iiii 11 FOUNDATION PLAN FOR CLARITY 6 MIL VAPOR BARRIER Ll 11=11= A— A 1'��6 16 R 17/8" MR-K P1 -9 ri! V ft; I I - ­ = I =.. ILI =.. ffliffi.5111111111 I . LI 1 x4 P.T. BASE NAILER FOR LOCATIONS) E___ E�� 'T #5 REINFORCING BAR #5 LAP SRUCE NOTE: 3 1/4" BASEBOARD PORT AT EACH *FOR BEARING WALL I E.- I I I I -I I I- Z, COMP. SOIL. (COMPACTED TO FILLED CELL TYPICAL W/ UPLIFT ONLY =1 I 1 111-4-1 ill III 1' 95% MODIFIED PROCTOR ASTM MIN. 2500 PSI CONC. SLAB m AT GARAGE CONTRACTOR --I - -_ -11� - D1557) MIN PSI MAY VARY PER TO CUT BLOCK OR POUR 41' 1-40 MUNICIPALITY. CURB DUE TO SLOPE III I M CONCRETE SLAB W/ 6X6 /,—NOTE: EXTEND FRAME WALL TO C.M.U. WALL CONNECTION rD TYPICAL EXTERIOR FRAME WALL FOOTING W1.4XW1.4 WWF OR "FIBERMESH" DECO FINISH 4" to 6" SEE TYP. WALL SECTION FOR ADDITIONAL SCALE: 3/4"=V-101" ',.N S3 SEE TYP. WALL SECTION FOR ADDITIONAL SCALE: 3/4"=V-101" 3 "I.,-S- .a I BELOW GRADE SLAB INFORMATION. SLAB INFORMATION. - E!6 le 00 - 6 x 6 W1.4 x W1.4 00 3 1/2" WWF OR FIBERMESH 6 MIL VAPOR min.) 4"--, BARRIER A 4 A GRADE COMP. SOIL. 00 (COMPACTED TO 95% (1) #5 REBAR w/ OPT. MODIFIED PROCTOR S E NCLOSURE ASTM D1557) I _q 3" MIN. CLR. ..-II (2) #5 REBAR CONT . 41 ON 3" CHAIRS TYP. 1 4" V-4" 1 STD. 90 NOOK (SEE MIN. U.N.O. DETAIL) TYPICAL WALL SECTION rA TYPICAL THICKENED SLAB EDGE rL SCALE: 3/4" = V-101" k S3 SCALE: 3/41i=11_011 � S3 OPT: DEPRESS SLAB 5 Y2" DEEP AND 6" BEYOND DOOR TO - --j— RECEIVE PAVERS/ DRIVEWAY =====,,,,-BLOCK WALL BEYOND BLOCK WALL BEYOND CONCRETE SLAB I EXPANSION JOINT PAVERS� 1411 O.H.D. RECESS �t 2� 13" SE O.H.D. RECESS 04 N A A." 4" ;0 .4 v 1­11 Ir SEE A/S3 OR J/S6 -1 4", - - SEE A/S3 OR J/S6 FOR REINF. INFO. 3" MIN. CLEARANCE FOR REINF. INFO. 3" MIN. CLEARANCE 1' 4" (1 STORY) / V-8" (1 STORY W/ DEPRESSED SLAB OPT.) 1'4" (1 ST RY) 1 1 1 8" (2 STOR) ') RY) GARAGE DOOR SLAB RECESS GARAGE DOOR SLAB RECESS SEE TYP. WALL SECTION FOR SCALE: N.T.S. � �3 SEE TYP. WALL SECTION FOR SCALE: N.T.S. '\_, �3 ADDITIONAL INFORMATION. ADDITIONAL INFORMATION. P.T. 2x 1/2" GYP. BD. HOLD GYP. BD. 1/2" FROM SLAB CONT. BEAD SEALAP INTERIOR 4 _-3 1/2" CONCRETE NAILS W 11/2' EMBEDMENT @ 12" O.C. STAGGERED, FROM BOTTOM PLATE TO CONCRETE (MIN. SHEAR 180# MIN. TENSION 120#) CONCRETE SLAB---, co F_ C-4 �=i 11711171 . - I 6 MIL VAPOR BARRIER _2X STUDS @ 24" O.C. U.N.O. GARAGE Zzz___1/2" GYPSUM WALLBOARD U.N.O. W/ DRYWALL SCREWS @ 8"O.C. —INSULATION PER CHART ON FLOOR PLAN CONT. BEAD SEALANT 6 x 6 W1.4 x W1.4 WWF OR FIBERMESH —4 14" 14" 1 INTERIOR WALL SLAB STEP NON-BRG. K SCALE: 3/4"=V-101" ��S 3 N CHAIRS 36' MIN. LAP [36" MIN, LAP) 8" 1'.4" 8' E = 7n x \x .. .... . ----#6 REINFORCING BAR #5 STD. 90 HOOK #6 LAP SPLICE TYPICAL INTERIOR BEARING REBAR DETAILS K"'F� WALL W/ UPLIFT G� SCALE: N.T.S. �3 SCALE: 3/4"=V-0" �3 EE PLAN 1 1/2" RECESS FOR VARIES 6 x 6 W1.4 x W1.4 FRAME -DOWN FALSE BEAM w/ ( SEE ROOF PLAN S.G.D. (U.N.O.) WWF OR FIBERMESH 10d NAILS TO TRUSS TOP CHORD FOR TRUSS I I AT 24" O.C. MAX. CONNECTION INFO SEE PLAN FOR & LAYOUT DESIGN TOP OF BEAM SEE ROOF PLAN ;0 FOR STRUCTURAL BEAM SIZE & 2X4 P.T. CONNECTION INFO PLATE 7/16" O.S.B. 2x4 #2 SYP P.T. FRAMING w/ MIN 7/16" O.S.B. SHEATHING SEE A/S3/J/S6 -` 1 8" z ATTACHED PER NAILING FOR REINF. INFO. co 0 C'(11-ICnill C: OPTION #1 LU I. - SEE TYP. WALL SECTION FOR ADDITIONAL SLAB INFORMATION. Uj Lij Uj SLAB STEP & RECESS (a) S.G.D. rM Cn SCALE: 3/4"=V-101" � �3 FLOOR PLAN FOR ,,,,,—SEE STRUCTURAL COLUMN SIZE & BASE CONNECTION INFO. SECURE 2x4 P.T. BTM. PLATE MASONRY WALL AND w/ 1/4"x3" TAPCONS AT 8" PAD FOOTING O.C. 8" MASONRY WALL EXTEND FILL CELLS TRIM PER PLAN TO FOUNDATION PAD CONT. FOOTING STEEL _\ MAT REINFORCING. i�! SQUARE CMU BLOCK BASE, �__ ;0 - GRADE SIZE VARIES PER PLAN -7=7 4 w/ MIN. (2) #5 VERTICALS LU 4 40 FILLED SOLID LU =) Ed I IE3 LU BRICK PAVERS or SLAB PER IkA"HKII'rV CDCf1Q 0- LU 0 LU LCUO Lu 8-0 — ILL 0 I _L1_1 �Fj j 4 — - / 4 0 z Y-O" FIN. FLR./-Jk lip -111- 7: =111-911 I III FOOTING U 11- BEYOND 16 PAD REINFORCEME TJ 3" MIN. CLEARANCE .4, ION (SEE SCHEDULE) FOOTING WIDTH IN 0. P PC I SEE SCHEDULE TAPERED COLUMN FRAMING KCD�12 PATIO COLUMN FTG. DETAIL �N SCALE: 3/4"- V-0" SCALE: N.T.S. �3 z —893 Z z run tj CL Z C 4--J Lu (D(13 U 0 ILLJ U0 0 2 C, V) U .2 Cal C14 W CO LU i,_ E 8 0) ce) 0 f2 LL 00 0 J) COL 0 6 BD* & AID o� V4# Mir r Uj 7, z F Cq Eli- Z OFESI d o o 10 p .000 To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code Sth Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. CD z 17�4 0 a) N l�� ;Lj C:) (n =1 ko , > -4 U-) rn < M M Ln z a. JA :2 -1' En r, a) Ln LL M U 4;k z z § E z LU 0 _j 0 z g U) 5480, n z LU x _j 02 Z < Z 8 0 Ln Z -0 N 06 .3: Ln z E-Z x c>L) r",4 LD 0 U z :D 0 0 188 1 U- U4 8�:� LLJ W z z r4 11714 Ln 0, LLJ Lij < di 2: < z � On �n qj I..; Ca zz 17u LU SCALE AS NOTED DATE 2/24/2014 TECH: FLORES VERSION NO' 10 SHEET NO. S3 (MONO) CIA W (2) 2x6 OR (2) 2x8 TOP PLATE SEE PLAN (2) 2x HEADER TO SIT 2x6 / 2x8 WALL BEYOND FLUSH TO THE OUTSIDE SEE PLAN FOR HEADER—\ SEE PLAN FOR SIZE CONNECTION '----2x DEAD WOOD @ MID POINT wl (3) 12d TONEAILS SPACED DOUBLE 2x TOP EVENLY PLATE I _j 2x BLOCKING @ EACH END W/ 1 Od @ 4" O.C. FROM EACH HEADER FACE TO BLOCKING (2) 2x HEADER PER PLAN 2x BOTTOM PLATE W/ (1) 1 Old @ 8" VARIES O.C. TO EACH HEADER FACE 2 x 6 (MIN.) FRAME _"N� WALL HEADER DETAIL ri SCALE: N.T.S. �, �4 12 TYPICAL WALL SECTION SEE ELEV. ,,,—SEE PRE-ENGINEERED WOOD TRUSSES @ 24" O/C UPLIFT CONNECTOR (SEE SCHEDULE) DOUBLE 2x4 SPF. #2 TOP PLATE 2x S.P.F. STUDS @ 16" O.C. SINGLE 2x CONT. TOP PLATE W/ (2) 12d INTO TRUSS ABOVE 2x CLOSURE WALL W/ STUDS @ 16" O.C. W/ USP SPT24 @ EA. STUD (3) 10d TOENAILS T&B AS REQ'D 2x BLOCKING @ MID POINT EVERY OTHER STUD W/ (3) 1 Od NAI CRICKET AS REQUIRED SINGLE 2x CONT. BASE PLATE W/ (2) 16d TO TRUSS BELOW 1/2" EXTERIOR GRADE SHEATHING FASTENED TO TRUSSES WITH 8d COMMON WIRE NAILS @ 4" O/C BOUNDARIES 6" O/C EDGES & 8" O/C FIELD IL USP SPT22 @ EA. STUD----- 2x P.T. PLATE 5/8" x 10" "J" BOLT @ 24" O/C MAX W/ 8" EMBEDMENT 8"X8"Xl 6" K.O. BLOCK W/ 1 #5 CONT. AND FILLED SOLID W/GROUT 1 #5 VERT. IN CONC. FILLED CELL W1 STD. 90A HOOK IN K.O. BLOCK KNEE WALL ABOVE MASONRY WALL DETAIL MOUNTING BASE NOT SHOWN FOR CLARITY SEE DETAIL K/S4 SEAT FOR BLOCK IS POURED, IN PLACE CONCRETE GARAGE FLOOR SLAB TROWEL FINISH SEE GENERALINOTES SLOPE FORWARD FOR DRAINAGE VENT OR 2ND FLOOR 1/2" MINIMUM CEMENT FINISH /—TYPICAL C.M.U. WALL STANDARD 3" DIA. TEE 3/4" FURRING STRIPS THREADED 3" DIA. EXTENSION 1/2" GYPSUM BOARD SCREW OFF (AP ry nIA 'i 1A11 r-iDVIAIA I I 0110CIA10 SEE TYPICAL WALL SECTION 12 PRE-ENGINEERED WOOD TRUSSES @ 24" O/C -Z(T:TYP.) SEE ELEV. UPLIFT CONNECTOR (SEE SCHEDULE) y P 7.) DOUBLE 2"x4" S.P.F. TOP PLATE FOR CLEAN -OUT 7 5/81, 8" 7 5/81, 8" 7 5/81, 8" 7/8" STUCCO FINISH PER ASTM C. 926 @ 8" O.C. OR 4d APPLY 3 LAYERS W/ TOTAL THICKNESS MIN. EXTENSION FROM DRYWALL NAILS 7/8" OVER METAL LATH. FIRST 2 EXTERIOR FACE OF BLOCK LAYERS 3/8" THICK EACH. 3RD LAYER 2 -SOLID AREAS ARE El SOLID AREAS ARE 1/8" TH IC K. WALL IS 1 1/2" MAXIMUM STEEL AND GROUT STEEL AND GROUT EXTENSION FROM EXTERIOR CRICKET AS REQUIRED FACE OF BLOCK WALL IS 2 1/4" INTERIOR FULL 8x8xl 6 BLOCK USP SPT24 @ EA. STUD WALL TO DRAIN Ot 1/2" EXTERIOR GRADE SHEATHING DOOR OPENING DOOR OPENING - DOOR OPENING Ct FASTENED TO TRUSSES WITH 8d EXTERIOR F1 COMMON WIRE NAILS @ 4" O/C BOUNDARIES 6" O/C EDGES & 8" CKING WALL CLEAN —OUT rA WALL O/C FIELD SCALE: N.T.S. '\-, �4 2X4 PT STUDS @ 16" O.C. (2) 2X4 PT STUDS UNDER HIP 1 ST COARSE 2ND COARSE v 3RD COARSE CARRIER/GIRDER TRUSS MASON TO LAY BLOCK AS SHOWN ABOVE. EVERY COARSE MUST BE BONDED TO THE REFER TO WINDOW PRODUCT APPROVAL COARSE BELOW. EVERY THIRD (3RD) COARSE THE 1 V DOOR JAMB WALL IS TO BE SHEETS FOR INSTALLATION INFORMATION BY WOVEN INTO THE MAIN FRONT TO REAR WALL AS SHOWN. USP HTA20 @ EA. STUD MANUFACTURER. L MAIN SPAN TYPICAL SECTION THRU WINDOW MASONRYLAYOUT MOISTURE BARRIER ROOF TRUSS 8"X8"X16" K.O. BLOCK W/ 1 #5 CONT. UPLIFT CONNECTOR SCALE: N.T.S. 1\ �4 (SEE SCHEDULE) AND FILLED W/ GROUT 1 #5 VERT. IN CONC. FILLED CELL--­"_�" W/ STD. 900 HOOK IN K.O. BLOCK VERTICAL JAM r,/Q-lr*II A � 2" 1 nni TQ AT A I /A" A 1 1 1A11 7111 A kir% 09 '21011 A On% IC r_1 ADA f'-C ALT. KNE WALL A OVE MASONRY WALL DETAIL KNOCK -OUT — NOTCH LINTEL WHERE REQUIRED BLOCK W/ (1) #5 FLOOR. ALL J-BOLTS WILL BE IN FILLED CELLS (2,000 PSI MIN. FOR CONCRETE PLACEMENT z CONCRETE). ANCHORS MAY BE COUNTERSUNK (BUT NOT REQUIRED) SCALE: N.T.S. �4 ----- - 4 RUSS BOTTOM CHORD OR 2x4 FBILOCKING W/ 2-16d TOE NAILS TO PROVIDE A FLUSH MOUNTING SURFACE. HORIZONTAL JAMBS DO NOT TRANSFER LOAD. 4 PIPE OR DUCT w/ PENETRATION THRU TOP PLATE wl MORE EACH END WALL 4 THAN 50% OF TOP PLATE WIDTH INSTALL SIMPSON x -UP COLUMN 811 STD. 9ifHOOK-/8"- 1 - 4 4 4 X_� DOOR STOP PSPN516Z w/ (12) 16d NAILS SEE PLAN FOR MORE INFO 4 TOP SPLICE 7 U ;i ':c CL MOLDING 4 2 ROWS 1 Od @ 3- O.C. (14 18-10d NAILS LINTEL BEAM W/ (1) #5 CONT. IN OPENINGS 2x TOP PLATE GARAGE NAILS TOTAL) EA. SIDE OF GREATER THAN 6-0" WIDE (U.N.O. ON 2-16d NAILS @ 24" O.C. OR DOOR <Lq,, SPLICE STAGGERED a , 0 PLAN) EQUAL TO TRUSS BOTTOM —I/L— CHORD OR BLOCKING 2 x 6 P.T. 5/8"DIA. X 12" EPDXIED ATR W/ MIN. 8" EMBEDMENT OPENING 0� *MAX 5/8" W/ 5/8" W.A. W/ 2x STUD @ 24" 1 Od @ 8" O/C 5 1/2" MIN. EMBED O.C. MAX. 11 FILLED CELL W/ (1) #5 VERTICAL -PROVIDE P.A.F. NAILS OR SEE FDN. PLAN FOR LOCATION 2x P.T. PLA rE EQUAL @ 12" O.C. STAGGERED FROM BOT. ATTACH ALL UPLIFT= 4290# (SPF / SYP #2) SEE A/S3 FOR REINF. INFO. PLATE TO CONCRETE DOOR TRACK W/MOUNTING ANGLE EXTERIOR STUDS W/ (4116d TOENAILS TO YOP PLATE NOTES: NOTE: REFER TO GARAGE DOOR PRODUCT APPROVAL SHEETS NOTE: QI-1, BOTTOM SPLIC FILL LINTEL AND ALL CELLS ABOVE LINTEL. FOR DOOR INSTALLATION INFORMATION PER MANUFACTURER. PLATE LENGTHS MUST 13E OVER STUD 4 NOTE: FOR BEAM DEPTH 22", PROVIDE A 4"x 4" INSPECTION TYPICAL INTERIOR NOW AT LEAST 4'-0" LONG. TYPICAL PORT @ EACH VERTICAL REBAR & DIRECTLY ABOVE THE LINTEL. AL BEARING WOOD FRAME W L KJ TYPICAL GARAGE DOOR BUCK r K rN TOP PLATE SPLICE DETAIL USP HTT16 VERIFY THAT ALL REINFORCEMENT HAS BEEN PLACED SCALE: N.T. S. SCALE: N.T.S. � �4 SCALE:NTS �4 BLOCKING (TYP.) PROPERLY. SCALE: N.T.S. L-ROOF' SS (Q SEE FLOOR PLAN FOR ADDITIONAL INFORMATION. F= 2240 LBS USP UPLIFT CONNECTOR ISEE SCHEDULE1 @ OPENINGS LESS THAN OR EQUAL TO 6'-0' IN WIDTH DO NOT REQUIRE ADDITIONAL STEEL REINFORCEMENT UNLESS NOTED ON FLOOR PLAN. MOISTURE BARRIER TYPICAL FILLED LINTEL ASSEMBLY G� SCALE: N.T.S. SEE PLAN FOR FOOTING DIMENSIONS GARAGE ENTRY FINISHED MASONRY DETAIL SCALE: N.T,S. HEADER SUPPORT NO. OF JACKS & STUDS REQ. AT OPENINGS OPENING 2" x 4" WALL 2" x 6" WALL ISTRAPS JACKS I STUDS JACKS STUDS SIZE EA END EA END EA END EA END 1'- 4' (1) (2) (1) (2) (1) USP LSTA30 40 - 9' (2) (3) (2) 1 (2) 1 (1) USP LSTA30 9'-16' (3) (4) (2) 1 (4) 1 (2) USP LSTA30 TUSP SPT4 SPT24� USP SPT4� SPT24� Fr SP SPT4 ROOFTRUSSABOVE 2X STUDS @ 24-1 O.C. PLATE OVERLAPPING 2X BLOCKING ::�t-2XTOP A /8"x`10" "J" BOLT \-NAILED @ 24" O.C. MAX. INTO MIN. (2) PER TRANSOM FRAMING TRANSOM BOTTOM PLATE FRAMING 10d NAILS @ 6" (2) 16d TOE NAILS STAGGERED EA. BLOCKING WIDTH OF OPENING VARIES 4" FORM CONCRETE INSET TO FLAT STRAPS PER CHART ABOVE TO BE BENT SECTION X P.T. id PLATE SEE SECTION AA/S1 CREATE A SOLID BASE FOR OVER TOP PLATE ** HOLD DOWN CONNECTIONS AND BB/Sl FOR ADDITIONAL DETAILS 2X8 WALL ABOVE ENTRY 1/2"X9 1/2" PLYWOOD BLOCK WALL ABOVE. NOT REQUIRED @ BEARING WALLS NOTED SCRAP MATERIAL WITHOUT UPLIFT USP SPT22 K.O. BLOCK W/(1) _j SEE FLOOR PLAN NOTES FOR \-USP SPT4 _U SP SPT4 usp sPT4 ;T1 -BOLTS @ 24" O.C. #5 CONT. & LU > REQUIRED CONNECTION RECESS MAX FILLED 0 Z LINTEL /rJ 5/8"X10" J-BOLTS 2-ROWS 12d NAILS STAGGERED 2X P.T. PLATE @ 7-0" O.C. FORM CREATES CONCRETE RECESS TO @ 12" O/C EACH FACE OR N_ 9. MASONRY WALL 2x4 (NOM.) RECEIVE GARAGE DOOR AND TO ALLOW FOR WATER SHED. 3-ROWS 12d NAILS STAGGERED @ 12" O/C FOR 2"xl 0" OR I I \2X8 P T BOTTOM PrTE 2x CRIPPLES @ HEADER I KEEP STIFFENER BACK FROM SIDES ENOUGH 16" O.C. W/ (2) 12d N I TO ALLOW SPACE FOR FLAT MASONS TOOLS TOENAILS T/B \-5/8"xl 0" "J" BOLT @ 24" O.C. MAX. USP SPT4 w/ (6) C (MIN. (2) PER BOTTOM PLATE) USP C (THIS IS A RECOMENDATION FOR CONSTRUCTION OF THIS FORM. ANY 1 Od x 1 Y2" @ 24" USP SPT4 SPT24� SP SPT4 MATERIAL OR CONSTRUCTION METHOD MAY BE USED PROVIDED END O.C. (2) 2x HEADER SEE PLAN Fr PRODUCT MEETS THE SHAPE AND DIMENSIONS OF THIS DRAWING.) MOUNTING BASE SHOWN 1 Od NAILS @ 8"----- \—INTERIOR HEADER 1 Od NAILS @ 4" 10d NAILS @ 6" O.C. IN POSITION GARAGE ENTRY FORM DETAIL O/C TYP. BOX HEADER (1) 2x SILL PLATE W/ (2) STAGGERED A STAGGERED ONLY 12d TOENAILS. TRANSOM FRAMING 2x6 MOUNTING BASE SCALE: N.T.S. DOUBLE 2x EXTERIOR HEADERS \-NAILED BEYOND. CRIPPLE STUD (1) 2x SILL PLATE W/ (2) INTO 8x8xl6 C.M.U. GARAGE DOOR TRACK MOUNTING BRACKET 7, TYPICAL (U.N.O.) 12d TOENAILS. OPENING LARGER THAN 4 ft 2x TRANSOM FRAMING L PLYWOOD (2) SILL PLATE W/ MP3 CLIPS TRANSOM FRAMING PLYWOOD FASTENED TO TRUSSES 0 rE SHEATHING GARAGE DOOR ROLLER GARAGE DOOR TRACK EACH SIDE SEE SECTION AA/ S1 AND WITH 8d COMMON WIRE NAILS @ 4" S4 CONNECTION ASSEMBLY "-2x STUDS TYP. BB/Sl FOR ADDITIONAL N O/C BOUNDARIES 6" O/C EDGES GARAGEFLOOR TRAVEL DIRECTION OF DETAILS & 8" O/C FIELD o GARAGE DOOR USP HTT16 TYP. U.N.O. SEE N/S4 LISP PLYWOOD HOLD DOWN CONNECTIONS SPT2�) o NOT REQUIRED @ BEARING MASONRY --o SHEATHING MOUNTING BASE DETAIL WALLS NOTED WITHOUT UPLIFT -RECESS LINTEL /-USP SPT4 USP WALL BELOW — 0 o o 5/8"X10" J-BOLTS @ 24" O.C. MAX. (MIN. (2) PER BOTTOM SCALE: N.T.S. SPT4 PLATE) SCALE: N.T.S. I - - 1, 'BOTTOM P.T. BOT. PLATE 4 ALTE NATE: POURED CONCRETE BASE FOR OF MOUNTING B E 5/8" DIA. ATR EPDXIED BLOCK WALL. RECESSED SPACE TO BE 2" ABOVE FINISHED 2X8 P. . BOTTr)A A�l MIN. 6" INTO BOND BEAM F OR GARAGE DOOR AND WATER GARAGE FLOOR. PLAT E I @ 24" O.C. SHED FORWARD THIS DRAWING. WALL HEADER DETAIL I I FRAMING DETAILS ABOVE ENTRY rR PARTIAL INTERIOR ELEVATION SCALE: N.T.S. �4 5/8"00" "J" BOLTS @ 24" O.C. MAX. SCALE: N.T.S. � �4 SCALE: N.T.S. (MIN. (2) PER BOTTOM PLATE) 0 (D - Z —8 z z a_ z Ul) (D (3) C—/) 4-j L, U LLJ 0 F_ E 0 V) 2 E 8 IN ce) 0) ce) C M ce) T.2 M CN 0-0o U_ CLO < 00 < A I ED. N r 9-1) C C, z "11/c" C, U_ 9LL. . &.Cl JU 3K (y) - Ul z FL z ...... ,L;3 o 6111"I"JI lilt! To the best of the Engineer's knowledge, Information, and belief, the structural plans and specifications contained withi these drawings comply with the Florida Building and seal Is only for the structural en gineering portions of he drawing pages bearing Engineer's signature and seaL Z r4 0 (v 1--� C) V) %0 > Ln M 0 4-J V) 170 Ln Q) !:I- Ln L_ LL C>L F- . (Y) cl� U CL 00 z z E ­0 z LU W _j g H z- -0 U -05 Z, 21 0 Lo z -0 N Lr) > 0 U i7i U) LU ix LU 0 r4 0 U4 z r4 LU W. z LLJ _j rN Ln T-4 LU X < LU z IN t5 < r, 0 Nr r-4 M TV-4 I N ZZ 17u LU 0 I'n T-4 Ln SCALE AS NOTED DATE 2/24/2014 TECH: FFLORES VERSION No' 10 SHEEr NO. S4 UA W SEE STRUCTURAL NOTES AND -� NAILING SCHEDULE FOR SHEATHING DETAIL TOP CHORD OR BLOCKING F FIRST FOUR ROWS OF TRUSSES @ EDGES OF 2x4 CRO�� BRACE SHEATHING APPROX. 8" FROM TYPICAL@ RIDGEFASTENEDAT 48" O.C. EACHJOINTW/(3) 10d MAX. & (2)1 Od TOE NAILS @ EA. END @ 48" O.C. TOENAIL W/ (2) 16d NAILS 2"x4" OUTLOOKERz SEE STRUCTURAL NOTES AND BACKNAILW/(2)16d NAILS @ 24" O.C. NAILING SCHEDULE FOR USP RT16 OR EQUAL @ SHEATHING DETAIL EA. OUTLOOKER 2"x4" .4`17, 1 OUTLOOKER N - @ 24" O.C. 45* 1 24" MAX. TOP CORD BLOCKING 45't 2X4 CONT"L" BRACE OR FOR FIRST FOUR FASTENED W/ (2) 1 Od EQUAL @ EA. ROWS OF TRUSSES @ 3"@ 24" O/C. CMID OUTLOOKER EDGES OF HEIGHT "L" BRACE TO EXTEND SHEATHING TYP. 2X4 KICKER x AT LEAST 90% OF WEB @ 8'-0" O/C. EXTEND @ LEAST 90% OF 2x4 CROSS BRACE WEB LENGTH & NOTCH @ LENGTH (SEE TABLE) APPROX. 8" FROM BOTTOM CHORD (SEE 2x6 P.T. GABLE TRUSS RIDGE FASTENED AT TABLE) SILL 1/2" CDX PLYWOOD OR EACHJOINTW/(2) 10d USP RT3A WITH 8-8d 7/16" OSB SHEATHING &(2)10dTOE NAILS@ ply FROM LEDGER TP ATTACHED W/ 10d EA. END BLOCKING NAILS @ 6" O.C. EDGES GYPSUM WALL BOARD GABLE TRUSS AND 12" O.C. FIELD 2"x4" PANEL BLOCKING @ 48" O.C. FOR THE FIRST 1/2" CDX PLYWOOD OR 1 0dX3" @ 3" O/C THROUGH CHORD INTO 74" P.T. PLATE (4) ROWS OF TRUSSES FROM EA. END TYP. BOTTOM CORD ATTACHED W/ (2) 16-d TOENAILS 2"x4" LEDGER (MATCH BOTTOM CHORD 7/16" OSB SHEATHING ATTACHED W/ 1 Od NAILS @ 6" O.C. EDGES AND 12" O 2x4 "T" ON TOP OF PANEL BLOCKING , FASTEN WITH 1 Odx3" @ 4" O/C SPACED WEEP SCREED SLOPE OF ADJACENT SCISSOR TRUSS) O.C. FIELD INSTALLED PER MANUF. 2"x6" P.T. SILL NOTCH 1" BRACE HERE @ 48" O.C. MOISTURE BARRIER 5/8" x 10" "J" BOLT @ 48" O.C. WEEPSCREED 5/8"x 10" "J" BOLT @ 32" O.C. MINIMUM 6" FROM- -0 - " O.C. TYPICAL. USP HTA20 OR EQ. @ 6 INSTALLED PER MANUF. PLATE SPLICES W/ 3/16"x2" 0 PLATE WASHER - USP HTA20 EA TRUSS ALTERNATE LISP LSTA1 8 STRAIGHT STRAP @ 4-4-MOISTURE BARRIER @ . O/C ALIGNED WITH GABLE WEB. ATTACH TO TRUSS VERT. WEB (24" O/C MAX.) Wn-1 Odxl 1/2" AND TO MASONRY W/ (3) 3/16"x 2 1/4" NOTE: IF EMBEDDED TAPCONS. STRAP MISSED VERTICAL SECTION SECTION WEB; USE ri Li:)i SCALE: N.T.S. MSTAM36 ON OUTSIDE SCALE: N.T.S. 1\ �5 REFER TO DETAIL J ON SHEET S5 FOR SEESTRUCTURAL X-BRACING, AND TOP x NOTES AND NAILING CHORD BLOCKING ;o ;o SCHEDULE FOR SP HGAM10 W/ (4) Wxl-3/4" WEDGE INFORMATION SHEATHING DETAIL OLTS & (4) SDS 1/4 .1 —111. 2 2"X4" CROSS BRACE 1 1/2" SCREWS WOOD TRUSSES 00 90 APPROX. 8" FROM -7- RIDGE FASTENED AT RAT RUN BRACING Lv EACH JOINT W/ (2) ,,,--2x4 AT 24" O.C. ON TOP OF 10d & (2) 10d TOE BOTT. CHORD FOR 4 NAILS @ EA. END TRUSS SPANS ATTACHED W/ 2 - 16d 1� 2X4 PANEL BLOCKING AT EA. TRUSS JOINT (2) 2" x 4" LAMINATIONS W/ (1) ROW (3) 2" x 4" LAMINATIONS W/ (1) ROW (3) 2" x 6" LAMINATIONS W/ (2) ROWS OF @ 48" O/C FOR THE FIRST (4) ROWS OF 2X4 BLOCKING @ 24' OF STAGGERED 10d COMMON WIRE NAILS OF STAGGERED 30d COMMON WIRE NAILS STAGGERED 30d COMMON WIRE NAILS TRUSSES FROM EA. (D = 0.148", L = 3") OR EQUAL (D = 0.207", L 4 1/2") OR EQUAL L = 4 1/2") OR EQUAL (D = 0.207 END TYP. TOP & O/C W/ 2 -16d TOENAILS @ EA. END NOTES: BOTTOM ATTACHED 1) ADJACENT NAILS ARE DRIVEN FROM OPPOSITE SIDES 4) FOR 4-PLY, PROVIDE 1/4" DIA. x 5 1/2" LAG SCREWS OR EQUAL W/ (2) 16-d TOENAILS MASONRY WALL OF THE COLUMN (SPACE AS SHOWN FOR 3-PLY) ARCHITECTURAL FINISH 2) ALL NAILS PENETRATE AT LEAST 3/4 OF THE THICKNESS 5) FOR 5-PLY, PROVIDE 1/4" DIA. x 7" LAG SCREWS OR EQUAL OF THE LAST LAMINATION (SPACE AS SHOWN FOR 3-PLY) EXT. WALL CONN. 3) EACH 30d COMMON NAIL MAY BE REPLACED W/ (2) 16d 6) REFER TO NDS SECTION 15.3 FOR ADDITIONAL INFORMATION NON - LOAD BEARIN LOCATION COMMON NAILS. (ONE INTO EACH OUTSIDE FACE OF t1"D B.U.C., SAME NUMBER OF ROWS, SAME SPACING) - SEE TYP. WALL SECTION FOR SCALE: 3/4" V-0" TYPICAL NAILING SCHEDULES FOR BUILT-UP COLUMNS 8� ADDITIONAL INFORMATION. SCALE: N.T.S. S5 2"X4" OUTLOOKER @ 24" O.C. W/ (2) 1 Od PER JOINT 1INIMUM 2x 'ROSS BRACING SEE PLAN FOR OCATIONS) 1 Odx3" O/C TOENAILJ 6"O/C W/ (2) 16d TYPICAL (2) 16d PER NAILS JOINT CONTINUOUS BOTTOM CORD BRACING 2"X4" MIN. SEE M/S5 CROSS BRACING DETAIL rj_,� SCALE: N.T.S.A S5 2"X4"��-/ RUNNERS ALTERNATE NON -DROP GABLE END DETAIL SCALE: N.T.S. GABLE TRUSS "L" BRACE W/ 1 Old @ 4" O.C. (SEE SCHEDULE FOR SIZE 12 AND LOCATION) 6.9 MAX. S5 GABLE END BRACING DETAIL S5 CONT. BEARING MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION SCALE: N.T.S. 8d @ 6"O/C WOOD TRUSSES USP HGAM10 W/(4)-3/16"x1-3/4" - WEDGE BOLTS & (4) SDS 1/4" x 1 1/2" SCREWS CKNAIL W/ (2) 2x4 OUTLOOKER 16d NAILS TOPCORD _17 '- N BLOCKING FOR USP RT16 OR FIRST FOUR ROWS EQUAL @ EA. OF TRUSSES @ OUTLOOKER 24" MAX. EDGES OF SHEATHING TYP. rl" BRACE TO EXTEND AT LEAST 90% OF WEB LENGTH ( EE TABLE) GABLE TRUSS 1/2" CDX PLYWOOD OR 7/16" OSB SHEATHING ATTACHED W/ 1 Od NAILS @ 6" O.C. EDGES AND 12" O.C. FIELD S 2x4 "T" ON TOP OF PANEL 1" BLOCKING, FASTEN WITH 1 Odx3" @ 4" O/C USP HGA10 @ 36" O.C. DBL. TOP STUD WALL PLATE (SEE TYP SEC ) 2x4 BLOCKING --2x4'7BLOCKING @ 48- O.C. 16d NAIL 1-1 BRACE ATTACHED 10d NAILS 4' GABLE TRUSS WEB DOUBLE 1" BRACING DETAIL (_5 SCALE: N.T.S. S5 2x4'rr" BLOCKING 2x4 BLOCKING @ 48" O.C. 1" BRACE ATTACHED 16d NAIL W/ 10d NAILS @ 4" 0. TYPICAL GABLE TRUSS WEB SINGLE 1" BRACING DETAI SCALE: N.T.S. DIAPHRAGM BLOCKING 48'� O/C M7Z7�r.,,_GABLE TRUSS TRUSS VERTICAL . . (2) 2"x8" 1" BRACE USP SPT24 @ EACH STUD FASTENED WITH (3) ER SIDE SECTION r4 16d P SCALE: N.T.S. SCISSOR GABLE 1711 BRACE@ 1\15� AS PER HIB 91 SCALE: N.T.S. 2 x 4 BLOCKING W/(2) 1 Od TOE NAILS @ EACH END @ 24" O/C (TYP) \-BRACING W/(3) 1 Od x 3" @ EACH CONN. @ 24" O/C MOISTURE BARRIER \-BOND BEAM MASONRY WALL ARCH ITECTU RAL FINISH _v` NON - LOAD EXT. WALL CONN. /C- BEARING LOCATIOR (UNEVEN CLG.) SEE TYP. WALL SECTION FOR ADDITIONAL INFORMATION. SCALE: N.T.S. 1" BRACING REQUIREMENTS STUD SPACING NO 1" BRACE (1) 2"x4" (U.N.O.) 1" BRACE 2"XIS" (U.N.O.) 1" BRACE 24" OfOl' - T-0" T-O" - 6f-01' 6-10" & GREATER SCISSOR GABLE (1) 2"x8" #2 S.P.F. @ EACH VERTICAL AND (2) 2"x8" FULL HEIGHT @ DIAPHRAGM BLOCKING NOTE: 1) 1" BRACE MUST EXTEND AT LEAST 90% OF WEB LENGTH EXCEPT, SCISSOR GABLE WHICH REQUIRES BRACE TO EXTEND FULL HEIGHT OF GABLE. 2) 1" BRACE TO BE FASTENED TO GABLE STUD WITH 10dx3" NAILS @ 4"O/C. 3) SEE 6/S5 FOR MORE INFO. PRE-ENGINEERED WOOD TRUSSES OVERLAP TRUSS BRACING AT LEAST TWO TRUSS SPACES SEESTRUCTURAL— NOTES AND NAILING SCHEDULE FOR SHEATHING DETAIL BACKNAIL W/ (2) 16d NAILS 2x4 OUTLOOKER @ 24" O.C. (OPTIONAL - SEE ELEVATIONS) I'll r SEE STRUCTURAL— TOP CORD BLOCKING USP RT16 OR EQUAL @ NOTES AND NAILING FOR FIRST FOUR ROWS 24" MAX. EA. OUTLOOKER SCHEDULEFOR OF TRUSSES @ EDGES SHEATHING DETAIL OF SHEATHING TYPICAL DOUBLE TOP PLATE 2"x4" CROSS BRACE 2x4 CROSS BRACE APPROX. APPROX. 8" FROM USP 8" FROM RIDGE FASTENED AT RIDGE FASTENED AT F11 SPT4 @ E EACH JOINT W/ (2) 1 Od & (2) EACH JOINT W/ (2) STUD 10d TOE NAILS @ EA. END 10d & (2) 10d TOE 2X6 FRAMED WALL - SEE NAILS @ EA. END WALL SECTION FOR SPACING 2x4 PANEL BLOCKING -1/2" CDX PLYWOOD OR 7/16" @ 48" OIC FOR THE OSB SHEATHING ATTACHED FIRST (4) ROWS OF W/ 10d NAILS @ 6" O.C. EDGES TRUSSES FROM EA. AND 12" O.C. FIELD END TYP. TOP & (2) 16d NAILS BOTTOM ATTACHED W/ (2) 16-d TOENAILS 2x4 PANEL BLOCKING a 48"A 2x4 BLOCKING O.C. FOR THE FIRST (4) ROWS Jv 2x4'7 ON TOP OF PANEL OF TRUSSES FROM EA. END TYP. TOP & BOTTOM ATTACHED BLOCKING, FASTEN WITH W/ (2) 16-d TOENAILS 1 Odx3" @ 4" O/C 2x4 LEDGER (MATCH BOTTOM CHORD SLOPE OF ADJACENT TRUSS) SECTION (a) SCALE: N.T.S. � �5 2X4 OUTLOOKER BACKNAIL W/ (2) f 16d NAILS @ 24" O/C TOPCORD BLOCKING FOR USP RT16 OR FIRST FOUR ROWS EQUAL @ EA. OF TRUSSES @ OUTLOOKER EDGESOF SHEATHING TYP. BRACE TO EXTEND 0 rl" AT LEAST 90% OF WEB LENGTH (SEE TABLE) GABLETRUSS 1/2" CDX PLYWOOD OR 7/16" OSB SHEATHING ATTACHED /- (2) 16d NAILS W/ 1 Old NAILS @ 6" O.C. SAND 12" O.C. FIELD JACK TRUSS —SEE PLAN FOR 2X4 "T" ON TOP OF PANEL--/ BLOCKING, FASTEN WITH L 2X4 BLOCKING W/ 1 Odx3" @ 4" O/C (2)12d TOENAILS SECTION r9, SCALE: N.T.S. 1\ �5 \-MINIMUM (2) 16d PER JOINT \-MINIMUM 2X4 TRUSS BRACING TRUSS BRACING OVERLAP DETAIL SCALE: N.T.S. 6" OVERLAP M S5 1" BRACE W/ 10d @ 4" O/C (SEE SCHEDULE FOR SIZE AND LOCATION) @ EACH STUD GABLE END BRACING DETAIL SCALE:34'=1V' MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION ENDJACK 1 V-0" MAX. LLJ 0 2: CORNERJACK Uj z 0 j HIP FRAMING REFERENCE PLAN E S5 z Uj 20'-0" MAX 20'-0" MAX "X" BRACE SEE DET. J/S5 n r CONTINUOUS BOTTO� CHORD BRACING 2X4 MIN. N VIA NOTE: 1) SEE TRUSS MANUFACTURER'S TRUSS ENGINEERING CUT SHEETS FOR ADDITIONAL PERMANENT BRACING THAT MY BE REQUIRED 2) '7 BRACING MAY BE USED IN PLACE OF PERMANENT BRACING PROVIDED IT EXTENDS OVER AT LEAST 90% OF THE WEB. REQUIRED MINIMUM PERMANENT TRUSS BRACING PLAN AS PER BCSI 1-03 SCISSOR TRUSS SCISSOR TRUSS CL /TOP & BOTTOM CHORD GABLE END BRACING @ 4'-0" D.C. MAX. FOR FIRST (4) ROWS OF TRUSSES SCALE: N.T.S. 2X4 BRACING @ 48" O.C. CONTINUOUS TO FIXED LOCATION ATTACHED W/ 2-10d @ EA. TRUSS (NOTE: BRACING MAY BE PLACED ON EITHER TOP OR BOTTOM OF THE BOTTOM CORD) COSMETIC DROP CEILING FRAMING W/ DROP CEILING BRACING DETAIL MEAN ROOF HEIGHT UP TO 30'-0" SCALE: NTS SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION WOOD FRAMED GABLE END BRACING DETAIL MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES SCALE: N.T.S. FOR WIND SPEED SPECIFICATION IDz Cf) z < I z v) (D Q) C-10 4--J U 0 U-j E Ch Of Ln 0 2 2 Co cli 8 0 g U) -S Z, C6 0 -, CL < 0 U-) 0 V ,q — 2 0 8 D. IN C 8-1) C A a Ul 0 -go co ClOci (A 3 k's z A -A p 41, ze i!11145. F LL a �� z 0 F E S Uj J,f,,,m /111 05 Ofill, l­_ 0 11 El I To the best of the Engineer's knowledge, information, and belief, the structural plan, and specifications contained within these drawings comply with the Florida Building Code Sth Edition (2014) Residential. Engineer's signature and seal is only for the tructural engineering portions of the drawing pages bearing Engineer's signature and seal. C) C� z 0 0­4 4-J CD (Al 53 t 0 e-, > Ln M z-4 ro 4..r U-) M Ln U_ zce U C:L CO < z 3i E,­ z C) LU _j 0 W ko uua z- g. 1i 1i - 0- - uj 4 -0: op 0 0: Z LW LU UZ xW LL 91 �i 8 z j� Lnzz U) z 0 _0 N < ul x > LLJ 0 U 0 uj 00 �p < �96 J < 0 Lj_ <0 5W d Z r�4 z UJI r4 Ln _j jlj Lij ZE 0 U. r-4 < z uj �_ C0 z Z tuV-4 LU IP z 0 0 lr�l :5 CL In 1 SCALE AS NOTED DATE 2/24/2014 TECH: FFLORES VERSION NO' 10 SHEET NO. S5 55 - u, W (1) LAYER TYPE 11 (#30) UNDERLAYMENT FOR ROOF PITCH >4:12 (2) LAYERS TYPE I OR TYPE 11 (#15 OR #30) UNDERLAYMENT FOR ROOF PITCH 4:12 OR LESS. 12 PRE ENGINEERED WOOD TRUSS @ 24" URRICANE ANCHOR @ EACH TRUSS O.C. MAX. SHINGLE ROO FOR UNDERLAYMENT REQUIREMENTS SEE R905. INSULATION — 15/32" CDX PLYWOOD OR 7/16" BAFFLE O.S.B. (SEE ROOF NAILING INSULATION P SCHEDULE ON SHT SNII) CHART ON FLOO PLAN LUMINUM DRIP EDGE ALUMINUM FASCIA 5/8" OR 1/2" HIGH STRENGTH CEILING 2x SUB FASCIA BOARD PER CODE W/ 13/8" DRYWALL SEE SOFFIT SHEET NAILS OR DRYWALL SCREWS 7" O/C CEILING & 8" O/C WALLS ATTACHED WALL SHEATHING TO 1/2" GYP WB (2) TOP PLATE W/ 8d @ 4" O.C., 2 ROWS DOUBLE 2x S.P.F. TOP PLATE 1X2 NAILER PLYWOOD SHEATHING 2X BLOCKING @ EA. WALL NAILED PER NAILING SCHEDULE SEE DETAIL C/S6 SHEATHING JOINT FOR MORE INFO LU LU 16" O,C. 2X S.P.F. STUDS W/ (4) 16d TOENAILS TO TOP PLATE 0 W 7/8" CEMENTITIOUS FINISH PER ASTM C. 926 APPLY 3 LAYERS W/ TOTAL THICKNESS 7/8" OVER 2x BOT. PLATE W/ (2) 10d @ 6" O.C. METAL LATH. FIRST 2 LAYERS 3/8" THICK EACH. 3RD 3/4" PLYWOOD DECKING GLUED AND NAILED W/ 10d _j UJ LAYER 1/8" THICK. COMMON @ 6" O/C EDGES AND 12" O.C. FIELD U_ = — INSULATION PER 1/2" GYP. WB OR 3/8" PLYWOOD/ TYPE 2-M-W OSB CHART ON FLOOR PLAN (DRAFTSTOPPING) TO BE NAILED W/8d COMMON @ 6" OIC TOONE SIDE OFTHE FLOORTRUSS FORAN AREA 1000SQ. B R �,FT, OF FLOOR AREA & SEALED PENATRATION AREA W/ FOAM. DRAFTSTOPPING SHALL DIVIDE THE CONCEA�rt S6 S6 SPACE INTO APPROX. EQUAL AREAS. FLOOR SYSTEM --METAL SEAT ER PLAN 0 OR FELT PAPER FOR MOISTURE A BARRIER 1/2" HIGH STRENGTH OR 5/8 GYP WB (OR 5/8" GYP. TYPE " X" @ GARAGE ONLY) W/ 13/8" DRYWALL NAILS OR DRYWALL SCREWS 7" O/C CEILING & 8'O/C WALLS STD. 90 HOOK (SEE DETAIL) 1/2" GYP WB 8"x8"X16" CONC. KNOCKOUT INSTALLATION PER BILK. W/1#5 ROD CONT. FILLED CHART ON FLOOR PLAN SOLID W/GROUT NOTE: LAP SHEATHING TO BOTTOM OF BAND JOIST TYPICAL USP LSTA24 STRAP W/ 8-10d x 1 1/2"NAILS TO STUD rEND SHEATHING TO )F BEAM OR GIRDER kTE W/ O.C. )OR TRUSS/JOIST 2ND FLOOR FRAME CONNECTION SEE J/S-6 FOR ADDITIONAL INFORMATION. USP LSTA24 STRAP W/ 8-10d x 1-1/2" NAILS TO STUD & 8-10d x 1-1/2" TO BAND JOIST @ EA. STUD z/1 2nd FLOOR WALL----- BAND JOIST 'USP MP4F @ 24" o.c. w/ 12-8d NAILS 1st FLOOR WALL SCALE: N.T.S. 2"x BOT. PLATE W/ (2) 1 Od @ 6" O.C. NOTES: * USE MP4F & EXTEND SHEATHING TO BOTTOM OF RIM BOARD/BAND JOIST FOR SHEAR WALL ONLY. USP LSTA24 STRAP W/ 8-1 Od x 11/2" NAILS TO STUD & 8-10d x 1 1/2" TO BAND JOIST @ EA. STUD 2ND FLOOR FRAME CONNECTION @ WOOD 1 ST FLR. UPLIFT CAP = 928 PLF SHEAR CAP = 355 PLF SEE J/S6 FOR ADDITIONAL INFORMATION. SCALE: N.T.S. SPACER BLOCKS E S6 1711 CORNER TYPICAL "T" AND CORNER DETAILS rN SCALE: N.T.S. �6 FINISH (1) #5 VERT. IN FILL CELLS (SEE FOUNDATION PLAN & NOTES) C') U) Lj 4"x4" INSPECTION PORT AT cr CL EACH FILL CELL TYPICAL 2"x4" PANEL BLOCKING @ 48" O/C 1x WD FURRING @ 24" O.C. LU (n CL AT GARAGE CONTRACTOR FOR THE FIRST 8'-0" OF END BASEBOARD to TO CUT BLOCK OR POUR C14 WALL FROM EA. END, (TYP.) TOP & MIN. 2500 PSI CONC. SLAB CURB DUE TO SLOPE BOTTOM CHORD ATTACHED W/ (2) 2ND FLOOR FRAMING SEE MIN. PSI MAY VARY PER NOTE: EXTEND DECO FINISH 16d TOE NAILS SECTION J/S6 MUNICIPALITY 4"to 6" BELOW GRADE DECKING --\ ATTACHED WALL SHEATHING 5K TO BOTTOM PLATE/CHORD W/ 8d '4 /FINISH 2K. @ 4" O/C, 2 ROWS STAGGERED 4 GRADE A. 4A 00 v ;0 A A 7 FLOOR TRUSS SEE FRAMING PLAN 6x6 W1.4xW1.4 9 Z FLOOR TRUSS WWF OR FIBERMES� SEE FRAMING WEEP SCREED PLAN INSTALLED PER MANUF. STD. 90'HOOK 2"X4" CROSS BRACE @ 48" USP HTA20 @ 24" O.C. W/ (3) # 5 REBAR ON 3" CHAIR--/ 411 (SEE DETAIL) O/C FOR THE 1 ST 2'-0" OF 10-10d X 1 1/2" NAILS INTO W/3" MIN. CLEARANCE END WALL W/ (2)10dx3" @ EA. BLOCKING TRUSS & MIN. 4" TYP 2-STORY WALL SECTION ri END INTO 2"X4" BLOCKING EMBEDMENT IN CONIC. SCALE: 3/4"=V-0" q6 2ND FLOOR FRAME CONNECTION � �R PARALLEL TO MASONRY WALL SCALE: 3/4"=V-0" 1\ �6 SEE TYP. 2-STORY WALL SECTION FOR ADDITIONAL INFORMATION. 2x STUDS @ 11" 2"x BOT. PLAT[ (2) 10d @ 6" OX PRE-ENGINEE FLOOR TRUSIE FLOOR CONNECTION @ MASONRY 1ST FLR. SEE J/S6 FOR ADDITIONAL INFORMATION. PROVIDE CONTINUOUS BLOCKING FROM B.U.C. TO MASONRY BELOW (4) 1/4" X 2 1/4" TITEN SCREWS TO MANSONRY WALL PER STRAP WOOD TO MASONRY CONNECTION W/ MSTAM36 SEE J/S6 FOR ADDITIONAL INFORMATION. ATTACHED WALL SHEATHING CONTINUOUS TO BOTTOM RIBBON W/ 8d @ 4" O.C., 2 ROWS STAGGERED 2X4 RIBBONS, EACH W/ 4-16d NAILS INTO EA. FLOOR TRUSS WEEP SCREED INSTALLED PER. MANUF. USP HTA20 @ EA. TRUSS W/ 10 - 10d x 11/2" NAILS INTO FLOOR TRUSS & MIN. 4" EMBEDMENT IN KO BLOCK B SCALE: 3/411=1 #_off S6 B.U,C. 8 - 10d NAILS TO STUD PER STRAP MASONRY WALL SCALE: N.T.S. RIBBONS DETAIL (FLOOR TRUSS) SCALE: 1 1/2"=V-0" �6 NOTE: SEE SHEATHING SEE TYPICAL WALL SECTION SPECS ON FLOOR C/S3 FOR ADDITIONAL INFORMATION 1/2" GYP. W.B. MIN. @ GARAGE SIDE IF APPLICABLE (1) ROW OF 2x BLOCKING @ MID —' /// HGT. FOR WALL HGT. < V-15". (2) 5/8"DIA x 10" "J" BOLT W/ 8" ROWS OF 2X BLOCKING @ 3rd PTS EMBED*MENT @ 24" O.C. W/ FOR WALL HGT, > 8'-6" 2"DIA.X 3/16" PLATE WASHER USP SPT22 @ EA. STUD (MIN. SHEAR 3500#. MIN. TYPICAL 2 x STUDS @ 16" O.C. TENSION 2600#.) 2X P.T. PLATE 6 x 6 W1.4 x W1.4 WWF OR FIBERMESH li-- A A 4� 'd A 0 'A (3) #5 CONT. ON 3" 8" 1'�� V-8" 8" CHAIR W/ 3" MIN. I I I CLEARANCE INTERIOR 2-STORY FRAME SECTION le"'S SEE TYP. 2-STORY WALL SECTION FOR SCALE: 3/4"=V-0" ADDITIONAL SLAB INFORMATION. S6 102" OSB EXPOSURE1 SHEATHING PROVIDE BLOCKING 0 REQUIRED I SECTION X- NOT FULL HEIGHT SHE (2)- 2x TOP PLATE BEYOND —15/32" OSB EXPOSUREl SHEATHING Lu SOLID 2x BLOCKING 0 ALL 0] SHEATHING 0 EDGES(SEE U) OPENING 1 SECTION X-X) L C R Lu —2x STUDS Lu BEYOND. u) SEE PLAN 21 1 IV _11� \-2x'4 P.T. BASE 2x RIBBON OR-/)" VERTICAL ��FIORIZONTAL PLATE BEYOND SEE PLAN 13LOCKING BETWEEN FLOOR WALL SHEATHING SYSTEM WALL ELEVATION DIAGRAM 4 FT. 4 FT. 2 2 5 FT. 4 FT. 5 FT. 4 FT. 2 0 4 FT 4 FT. 4 FT. 2x CRIPPLES @ — 16" O.C, W/ (2) 12d TOENAILS T/B 10d NAILS @ 81, O/C TYP. DOUBLE 2x CRIPPLE STUD TYPICAL (U.N.O.) ROOF NAILING ZONE DIAGRAM ROOF NAILI H E : NAILING ZONES (SIJ INGLE AND T LE U) Lu ZONE 1: Bd RING SHANK NAILS @ 6" O.C. ON EDGE AND 6" O.0 IN FIELD U) ZONE 2:8d RING SHANK NAILS @ 6"C.C. ON EDGE AND 6" O.0 IN FIELD z ZONE 3 Eld RING SHANK NAILS @ 4" O.C. ON EDGE AND 4"O.0 IN FIELD (D z (NOTE: IF 5/8" PLYWOOD IS USED, CONTRACTOR MUST USE 10d RING U_ 0 SHANK NAILS) NOTE: (n ROOF SHEATHING: (APA RATED EXPOSURE 1) 1/2" PLYWOOD (TILE) OR 7/16" OSB MIN. (SHINGLES) SPAN RATED 24/16 Lu u- 8 a SHEATHING MAY BE INSTALLED VERTICALLY OR HORIZONTALLY, ATTACH PER NAILING SCHEDULE. PANEL EDGES WILL NEED TO BE ATTACHED TO U) uu- STUD AND OR BLOCKING AT ALL EDGES. '2u,00 LL AMINIMUM 1/8" SPACE IS RECOMMENDED BETWEEN PANELS AT EDGES AND END JOINTS TO ALLOW FOR EXPANSIONS FASTENERS SHALL NOT . PENETRATE SURFACE MORE THAN 1/8" "S" = NAIL 3/8" 3/8" SPACING 4" 1/2" S 1/2- ac--it 1/2" 4__ SINGLE NAIL EDGE SPACING DOUBLE NAIL EDGE SPACIN ' G NAIL AT BASE 2 ROWS @ 4" D.C. W18cl COMMON NAIL NAIL AT TOP PLATE TWO ROWS @ 4" O.C. W18d COMMON NAIL @ NAIL OPENING PERIMETER @ 3" O.C. W/Eld COMMON NAIL @ NAIL INT. AT 3" D.C. W/8cl COMMON NAIL STAGGER ALL VERT. JOINTS & NAIL @ 4" O.C. W/8d COMMON NAIL SHEATHING SPLICES @ HEADER - NAIL SHEATHING TO HEADER W/ 8d COMMON NAILS @ 4" O,C. @ (2) 8d NAILS @ Y D.C. TO EACH TRUSS END OR @ VERTICAL MEMBER IF GABLE END OTE: 8d NAILS FOR WALL SHEATHING MUST BE MIN. 131" X 2 1/2" DO NOT OVERDRIVE NAILS, FASTENERS SHALL NOT PENETRATE SURFACE MORE THAN 1/8'. AT ALL PANEL BLOCKING LOCATIONS MIN 2 X 4 #2 SPF TURNED VERTICAL W1 7/16" OSB FLITCH PLATE TO W/ (2) 12d TOENAILS EA, END, NAIL FLITCH PLATE TO VERTICAL W/ (4) 8d NAILS (2) 8d NAILS @ Y O.C. WALL SHEATHING INSTALL. & NAILING SCHED. � �6 S4 BOX HEADER ONLY SEE PLAN FOR REQUIRED --- CONNECTIONS LOAD BEARING/EXTERIOR FRAME WALL HEADER DETAIL (2) ROWS OF 2x BLOCKING @ THIRD POINTS 5/8"DIA. x 10" "J" BOLT W/ 8" EMBEDMENT @ 24" O.C. W/ 2"DIA.X 3/16" PLATE WASHER (MIN. SHEAR 3500#. MIN. TYPICAL TENSION 2600#.) 2500 PSI CONCRETE MIN. 6 W1.4xW1A SLAB W/ 6x WWF OR FIBERMESH 7 .A E ..A C,4 'A* 'A M I M I 4- =-.I I 1E1 1511 1= - —11 1=1 I JEE1 I 1 fl Ll I 2-ROWS 12d NAILS STAGGERED @ 12" O/C EACH FACE OR 3-ROWS 12d NAILS STAGGERED@ 12" O/C FOR 2"xl 0" OR GREATER HEADER SEE FLOOR PLAN NOTES FOR REQUIRED CONNECTION (2) 2x HEADER SEE PLAN INTERIOR HEADER (1) 2x SILL PLATE W/ (2) 12d TOENAILS. EXTERIOR HEADERS (1) 2x SILL PLATE W/ (2) 12d TOENAILS. OPENING LARGER THAN 4 ft (2) 2x SILL PLATE W/ MP3 CLIPS EACH SIDE 2x STUDS TYP. P.T. BOT. PLATE FLOOR TRUSS me HEADER SUPPORT NO. OF JACKS & STUDS REQ. AT OPENINGS OPENING 2"x 4" WALL 2"X 6" ILL STRAPS JACKS STUDS JACKS STUDS SIZE EA END EA END EA END EA END 1'4-_ (1) (2) (1) (2) (1) USP LSTA30 4'-9' (2) (3) (2) (2) (1) USP LSTA30 91-16, (3) (3) (2) (3) (2) USP LSTA30 PLYWOOD SHEATHING NAILED PER NAILING SCHEDULE SEE DETAIL C/S6 FOR MORE INFO -2X STUDS @ 16" O/C 7/8" STUCCO FINISH PER ASTM C. 926 APPLY 3 LAYERS W/ TOTAL THICKNESS 7/8" OVER METAL LATH. FIRST 2 LAYERS 3/8" THICK EACH. 3RD LAYER 1/8" THICK. USP SPT22 @ EA. STUD 2X P.T. PLATE WEEP SCREED INSTALLED PER. MANUF. 00 FINISH GRADE 0? 11-1 I�L—I I (3) # 5 REBAR ON 3" CHAIR ----14" V-8" W/3" MIN. CLEARANCE ALTERNATE FOOTING v @ WOOD IIST FLR. SEE J/S6 SCALE: 3/4"=V-0" FOR ADDITIONAL INFORMATION. (D M 7 co z 10 = < I Ck- z (A QD Q) 4-j Lu (Z 0 U — LU 0 E 0 0 U) M LU E 8 as C1`1 a) ce) 0) 0 M Cl) cm a M Ic C14 000 U. 00 = - 00 0 M X C1. < 0 CL < A 8 D. N. r. 8 1). C Ick" 44 z C*4 0., 4 r - 04 0 gr . Mi %L 0 15 z F L C4 0 a 0 * ­ OF z E S us W A 10 - - d ic �0- IRli . 100 El To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code 5th Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. CD 0 z r1j 0 cu r-, 1-4 W CD 14 CD > Lf) ro P-4 M a 0 , N 4-J Lr) Ira Lr) _0 z (n v- " 01 N (v 0 Ln C:L ell-, U CL 00 z E 3: z C:) WLU _j C:) 80 M 33! Lu -1 9: g� I 10 8 Ln z 0 -a N Ln z W > ("-4 U < LU 0 I- F= 0 I r x 6 gi� < U 0 r-4 r11-% ILI 0. z azr . < Z v- (*-4 a Uj 0: t!� 0 �gj� Z LU Lf) L LU < z co 1­4 z Z tu Uj lr�l U SCALE AS NOTED DATE 2/24/2014 TECH: FLORES F VERSION NO. 10 SHEET NO. S6 2x12 SYP SCAB 2x4 GLUED AND NAILED (EACH ALIGN THIS STUD WITH STRINGER -SIDE) TO BOTTOM EDGE OF 2xl 2 FACE OF 2ND RISER 3/4" RISER CUT TO FIT STRINGER MAINTAIN BETWEEN j" AND�`GAPTOPAND BOTTOM, GLUED AND NAILED TO STRINGER STRINGER MUST MAKE FUL 2x4 BEHIND RISER CONTACT WITH LANDING BLOCKING FOR 1 x4 GLUED AND NAILED TO STRINGER STRAP GLUED TO FLOOR 2x4 DRAFT RISER AND TREAD x STOP ///z/�/z/ JOIST z 2X8 SYP DRYWALL STOP MUST NOT TOUCH STRINGERS !1 7 7 7 77 77-7, ALL STAIR STRINGERS AND TREADS TO BE #2 SYP (MIN.) THREADS, RISERS, AND 3/4" PLYWOOD NOT SHOWN IN DETAIL FOR CLARITY ALL WOOD TO WOOD CONNECTIONS TO BE GLUED (PL 200) AND NAILED (MIN. (2)16d). 1314x 11 JVL 2x4 UNDER STRINGER - GLUED AND NAILED TO LANDING 2X4 UNDER STRINGER GLUED AN NAILED TO LANDING BLOCKING D 2x4 PT NOTCH_ INTO STRINGERiiiiiiiiiiiiiiiiiiiiiiii� —D illi" H �-i BLOCKING FOR STRAP L-iii blocking -20" FLAT STRAP NAILED TO RISER AND THEN WRAPPED AROUND STUD (USP MTi PLAN VIEW SCALEFT"=V-0'� E: THESE DETAILS ARE NOT PLAN SPECIFIC. THEY ARE PROVIDED TO YOU AS A STANDARD TO CONSTRUCT STAIRS. REFER TO PLAN DETAILS FOR RISE AND RUN INFORMATION. mlll� SYP 2x8 SYP 2x8 SYP PT NOTCHED INTO STRINGER - D NAILED TO FLOOR WITH GLUE STRINGER CONTACT POINTS 2 4 CUT DOES NOT BEAR IN WALL GLUED TO 2x8 F SECTION VIEW "All SCALE: 1 V-0i" STRINGER MUST MAKE FULL CONTACT WITH LANDING 2x SYP CUT TO FIT BEARS IN WALL 2x12 SYP B IN WALL 2x6 SYP E 2X4 PT NOTCHED 11's AND NAILED TO FL( 2X4 CUT ON BEVELiii/ AT STRINGER CON' DOES NOT BEAR IN WALL SECTION VIEW "ID11 SCALE: 1 Viiii FILLER STRIPS ADDED PLYWOOD GLUED & SCREWED PLYWOOD DECKING F04-2x SY CUT TO FIT BEARS IN WALL _----2xl2 SYP BEARS IN WALL BULLNOSE DETAIL SCALE: 1 V-0i" NGER 3LUED NAILED SECTION D-D 2x4 SPF NOSING GLUED AND SCALE: 1 V-0.1- NAILED MATCH NOSING ON OTHER TREADS —3/4 PLYWOOD 10 ON DECK 3/4" RISER CUT TO FIT MAINTAIN BETWEEN SYP GLUED H AND�`GAPTOPAND AND NAILED TO BOTTOM, GLUED AND -AH 2x4 syp FRAMING 2x4 SYF NAILED TO STRINGER L�I, blocking for BLOCKI 4 3 FOR .f 2_x4 DRAFT 2x12 lo Z. r= strap (U STRAP 1:1 M STOP TREAD MTW`12� 2x12 TREAD GLUED GLUED AND AND lo NAILED--i NAILED---\ 2x4 PT NOTCHED INTO x8 SYP DRYWALL STOP MUST STRINGER AND TAPCONED I INTO FLOOR WITH GLU NOT TOUCH STRINGERS STRINGER CONT T AC 2X4 BLOCK IN KNEEWALL FOR 2x12 NAILING POINTS x4 GLUED AND NAILED TO STRINGER FOR DRYWALL SPACING ji"�H SECTION VIEW SCALE: v-0, 2X4 PT NOTCHED INTO STRINGER AND 2 TAPCONED� x Iii, INTO FLOOR WITH GLUE_A NOT TOUCH STRINGERS STRINGER CONTACT GLUED AND NAILED TO STRINGER POINTS OR DRYWALL SPACING B H 2x4 SYP BLOCKING FOR STRAP (USP MTW12) BEHIND RISER SECTION V SECTION VIEW "Ell SECTION VIEW SCALE: v-0. O� F ST( 2X4 SCALE: V= V-0i" IEW 111311 SCALE: 1 V-0" ;ER BLOCKING FOR 2x12 PT UNDER 2x12 ATTACH ALL COMPONENTS OF STAIR TO CONC. W/ J" x 2 J" TAPCONS @ MAX. 32" O.C. 4 GLUED AND NAILED TO STRINGER DRAFT )P B SYP DRYWALL STOP JST NOT TOUCH 'RINGERS G x4 BLOCKING FOR 2x12 (4 PT UNDER 2x12 TOP OF STRINGER --J---PROVIDE MOISTURE PROTECTION ATTACH ALL COMPONENTS OF STAIR TO CONC. Wit J" x 2 J" TAPCONS @ MAX. 32" 0. C. _1x4 GLUED AND NAILED TO STRINGER 11C11 SECTION VIEW SCALE: 1 V-0" CONN. TO BOTT OF NEWEL POSI PER CONTRACT FLOOR GIRDER PROVIDE SOLID BLOCKING BELOW ALL NEWEL POST 2X4 CUT ON OR 1 x 16" VL BEVEL GLUED FROM JOIST TO JOIST. USE AND NAILED TO 2 X 12 BLOCKS, GLUED AND LVL NAILED TO JOIST. NEWEL POST. SECTION VIEW G-11 SCALE: 1 V-0" L POST LET INTO iLOCK IDE <ING BLOCKING SCALE: 1 V-0i" 0 1 MIM k.,#U1N0 I MUU I 1UP4 Ur. I /-XILO (IF 11 X1 7 REDUCE SCALE .5) SCALE: AS NOTED 2X8 BLOCKING FOR NEWEL POST TO ANCHOR TO. (GLUED AND NAILED) FLOOR TRUSSES JOINT -TO )ISTS) NAILED AND TOP PLATE NTO RIM BAND, JD NAILED TO WALL BELOW JOINT TO )fSTS) 2X USP (I ECTION VIEW 11H11 11. V-01., SCALE: Ln z ce) —8 z < z V) (D 4-J Lu C) 0 LU ul T Ili- E 0 21, V) C) .20 04 0 M uj E 8 ass 0 M to r- cn j! 'S Q 00c, t 0 6 < LA /0 v 0 111111 01 A ED. NrBI)C ur) I C-4 00 u_ 6i.s. k4u 0. :2 Uj 1�11 < j, * . . 6 L J0 To the best of the En s knowied'geiin 'e%;, and belief, the structural W% i, W*) rolli'lli ntained within these drawings comply w1V he Florida Building Code Sth Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. CD 0 z C114 0 (v 0­4 41 C:) Ul) _ =) to 14 > CD C:) M Ln z C U_ al� U z < 0. 00 . %­0 z 3.. E Wz C) Uj _j 0 g ow W a i.- ui Ln U) z 0 -a T r*.%, Ln x 0 (1) > Lij 0 117�4 LL ui z z Uj r4 Lr) Lij L]j 117.4 < z LU ri� z Z :5 LU 0 rn -1 10. 1 (n I uj E SCALE AS NOTED DATE 2/24/2014 TECH: FFLORES VERSION N 0' 10 SHEET NO. ST DOOR JAMB (REFER XA44 11/2* DRYWALL DOOR JAMB (REFER 11X4 F1/2"DRYWALL DOOR JAMB (REFER 1X4 F1/2" DRYWALL UNACCEPTABLE INSTALLTION MAX. 8" L11 TO SHT. SDW2-K1 P.T. TO SHT. SDW2-K1 TO SHT. SDW2-K1 FOR CONN. DETAILS *t PROPER INSTALLATION DO NOT DO THIS 2"x BOT. PLATE W/ (2) 1 Od @ 6" O.C., FOR CONN. DETAILS FOR CONN. DETAILS 1X4 X 4 #5 REBAR (TYP) *411110 3/4" PLYWOOD DECKING GLUED ATTACHED WALL SHEATHING TO -1 X 4 3-1/4" LONG X 3/16"0 FURRING 3/16"0 X 3" LONG //// FURRING 3/16"0 X 3-1/2" LONG FURRING #5 REBAR AND NAILED W/ 8d COMMON @ 6" O.C. EDGES AND 12" O.C. FIELD 2X BOTTOM PLATE W/ 8d @ 4" O.C., 2 ROWS STAGGERED TAPCON. INTO TAPCONS TAPCONS STAGGERED STAGGERED @ 16" I 2X8 ElIX8 (TYP,) BLOCK@ SPACING 1" DETAIL 1X8 P.T. STAGGERED@ 16"O.C. O.C. 2-ROWS INTO 2-ROWS INTO 000 4 "It PER MANUFACTURE MASONRYTHROUGH MASONRYTHROUGH 1x8 P.T. 1-1/211 DETAIL— 311 DETAIL 11 D. 90- HOOK (TYP.) STD. 90^ 2x BAND JOIST W/ FACE NAIL 1 Od @ TOP & BTTM CHORD, AND (8) 1x4 P.T. & 1x8 P.T. & 2x8 P.T. FILL SOLID BOTH CELLS HOOK (TYP.) FACE NAILS 10d @ TRUSS VERT, WEB ETAL SEAT PLATE T A N TAPCON @ 16" CO 0 C 4 O.C. & 4" FROM F R 1X4 P.T.— 3/16" x 3 -1/2" DOOR JAMB (REFER 1/2" DRYWALL F E, 7- U LJIA J 7 NOTE: LAP SHEATHING TO E H END DOOR JAMB (REFER EACH END W/ MIN F-1X4 DOOR JAMB (REFER TAPCON TO SHT. SDW2-K1 FOR f 2" EDGE DIST. TO SHT. SDW2-K1 2 EDGED IS TO SHT. SDW2-K1 CONN. DETAIL - BOTTOM OF BAND JOIST TYPICAL FOR CONN. DETAILS FOR CONN. DETAILS 1 Od @ 12" 70.C. 1X4 -j 13"'VZ"' FURRING z 2X8 P.T. WITH 3/16' "0 X LONG TAPCONS S + NOTC EB (0) FIRST COURSE USP HGAM 10 @ 12" O.C. w/4-SDS 1/41 1/2" SCREWS INTO BAND T 2X8 P.T. 2X8 T ", 2x P.T. AS REQ'D STAGGERED @ 16" O.C. JOIST & (4) 3/16"x1-3/4" WEDGE 2x DETAIL 2 1/4" DETAIL 2-ROWS INTO MASONRY 3-1/411 DETAIL NOTCH WEB AT THE FIRST 2 COURSES BOLTS INTO K.O. BLOCK BUILDOUT OVER SIZE DOOR -WINDOW ROUGH OPENINGSK'ccN), FILLED CELL PER FOUNDATION PLAN FILLED CELL INSTALLATION f/ H� RETROFIT FOR MISSING EMBEDDED STRAP SCALE: N.T.S. � �s SCALE: N.T.S. � �S SEE TYP. 2-STORY WALL SECTION FOR ADDL. INFO SCALE: N.T.S.. 2x8 P.T. BUCK -CONNECT TO BLOCK SECTION A -A UPLIFT CAPACITY = 945 # FOR 1 STRAP W/ 1/4" x 3 1/4" TAPCON ( 1 1/4" M IN. = 1890 # FOR 2 STRAPS FILL I st 4 COURSES EMBEDMENT INTO BLK.) 1/4" MAX 2'- 8" 1-PLY PRE-ENGINEERED TRUSS SOLID WIGROUT 1 X 4 FURRING SOLID BLKG. AT TOP BTWN. ARCH BLKG. & BUCK ­-`- F 1/4" x 3 1/4" TAPCONS / I USP RT1 6M W/ (8) NA1 1 NAILS & (6) 1" x 2j" BLOCK HEADER TAPCONS 1/2" DRYWALL (IF TRUSS IS 2 PLY INSTALL USP HTWM16 W/ (6) 10d NAILS x 11' NAILS AND 8d NAILS AT 8" O.C. AT BUCK (4) J" X 1 t'WEDGE BOLTS (1) STRAP 1225 5A 2 x 8 4 DIAGONAL (4) 10d NAILS INTO INTO LEAVE A CUT OUT IN O.S.B. ON THE (2) STRAPS 2450#1) BRACE(S) 2 x 8 BRACE/ BLKG. BLKG 7n INSIDE TO ALLOW FOR INSULATION 7/16" OSB TO BE INSTALLED BOND BEAM OR CAST FOR OVERHANGS BETWEEN OVER 11/2" CUT HOLE IN O.S.B. FOR BUILT UP PLWD. BUCK ARCH PANEL OLEIN S 13 - FOR i O� S POLY CELL IN THIS AREA '-2x845 DIAGONAL BRACE AT EA. IN PLACE BEAM CONTACT ENGINEER OF RECORD FOR FURTHER INSTRUCTIONS. z 1 4 SCRIBE (NOTCH) FACE OF ARCH W/ (3) 10d NAILS i, 1 mail JmTr) ) ".q BACKSIDE TO FIT ARCH (4) 1 Od NAILS INTO 2 x 8 AT EA. END RETROFIT TRUSS DETAIL OVERHAN CONNECT W/ 8d NAILS BRACE/BLKG. \-2 N.T.S, x 4 SOLID BLKG. (FULL WIDTH OF WALL) BTWN. OSB INSTALL WDW. SCREW ANCHOR--/ ARCH FACES W (4) 10d NAILS THRU OSB INTO 2 x 8 PROVIDE TAPCON WITHIN RETROFIT WALL OVERHANG DETAIL (NTS) INTO ARCH BLKG. PER 4" MIN. OF BRACE 2 X 4 #2 SYP SCAB TO SIDE OF INSTALLATION DETAILS A -A PROVIDE TAPCON PER WDW. INSTALLATION DETAILS ORTHRU TRUSS AS SHOWN FOR O.H. UP TO 7-6" FOR OVERHANGS BETWEEN 3/4" TO 1 1r2" 1-1/2" THK. OR MORE BUCK WITHIN 6" MIN. OF START OF ARCH 2X6 SYP #2 CONT. (MATCH TRUSS DEPTH DOUBLE 2x4 SCAB FOR 7-15" TO 4'-0" O.H. START OF ARC IF TRUSSES USED) W/ (3) #6 X 4%," WOOD NOTE: FOR OVERHANGS LESS THAN 3/4' - NO REPAIR REQ'D. 4'MAX. RAD. SCREWS @ 16" O.C. MAX. OR IF MASONRY )(Ov (2) 10d NAILS @ 8" O.C. 6A ARCH DETAIL i WALL USE (3) 1/4" X 3 1/2" TAPCONS AT 16" TO TRUSS TOP CHORD SCALE: N.T.S. SS 6)1 O.C. 12 + + + rl&y PLYWOOD SHEATHING 11-011 51-011 L JACK TRUSS PROVIDED BY SEE + + TRUSS COMPANY OR PLAN 2x6 #2 SYP @ 24" O.C. + + + + OJUINISH FLOQR 2 x 8 BUCK - CONNECT TO BLOCK SECTION + + BLOCKING AS b WITH 1/4" x 3 1/4" TAPCON (11/4" MIN. B-B ROOF SHEATHING ATTACHED + REQUIRED > EMBEDMENT IN 0 PER NAILING SCHEDULE ILL TO SUPPORT /4" MAX 2-41 8" TRUSS + SOFFIT + 4` #5 BAR 4 BLOCK HEADER SOLID BLKG, AT TOP BTWN. ARCH (5) -12d + + tv, i CENTERED W/ BLKG. & BUCK 2X6 TO 2X4 USP RT3A 2X4 SYP IN TOP 1 X 4 FURRING EACH TRUSS KNOCKOUI C14 CHAIR BLOCK 8d NAILS @ 8" O.C. AT BUCK 2 x 8 VERT. W/ (2) 1 Od NAILS AT EA. END B TW""\ PROVIDE (2) MIN. PROVIDE 2x CONT. W/ (3) CONNECTOR MONO FOOTING 1% % PROVIDE 2 x 8 DIAG. BRACE SIZE AND REINF. PER PLAN 0 VERT. BRACES WHEN HGT. F TAPCON AT EA. SIDE BUCK - (1) WITHIN 4" 12d NAILS SEE LINTEL AND SECTION DETAILS BRACE EXCEEDS 24" JACK TRUSS PROVIDED BY--// SCHED. LEAVE A CUT OUT IN O.S.B. ON T MIN. OF START OF TRUSS COMPANY OR 2x4 A CLEAN FILL 2 x 8 VERT. BRACE(S) INSIDE TO ALLOW FOR INSULATION ARCH #2 SYP @ 24" O.C. tENTER SOftIT DIRT TO BE INSTALLED J BUILT UP PLWD. BUCK - 4'-0" MAX SEE PLAN PRECAST LINTEL 1% A ffTANDARD z 9 SCRIBE (NOTCH) BACKSIDE 7/16" OSB ARCH PANEL 2X4 SYP #2 CONT, (MATCH TRUSS D EPTH % SEE ELEVATION gy #5 BAR IN HOOK &4 TO FIT ARCH CONNECT W/ '�--2 START OF ARC IF TRUSSES USED) W/ (2) #6 X 4%" WOOD FOR OVER HANG FILLED CELL, 8d NAILS x 4 SOLID BLKG. (FULL WIDTH OF WALLS) 4'MAX. RAD, SCREWS @ 16" O.C. MAX. OR IF MASONRY -(MAX. 4'-0") " , %j BTWN. OSB ARCH FACES W/ (4) 10d NAILS EQUAL EQUAL_ WALL USE (2)1/4" X 3 1/2" TAPCONS AT 16" - , * INSTALL WDW, SCREW — THRU OSB INTO 2 x 8 O.C. ANCHOR INTO ARCH BLKG. STEMWALL FOOTING SIZE AND PER INSTALLATION DETAILS ARCH DETAIL SECTION @ ENTRY SECTION @ ROOF EXTEN SION rM REINF. PERLAN AND STEMWALL MONO TO STEMWALL FOOTING .13-13 SCALE: N.T.S. �s SCALE: 3/4" V-0" 1\is� SCALE: 3/4" V-0" SECTION DETAILS SCALE: 3/4" V-0" GLASS BLOCK INSTALLATION NOTES NOTE: IF RETROFIT FILLED CELL CONDITIONS A) COVER SILL AREA WITH A HEAVY COAT OF ASPHALT EMULSION. ALLOW EMULSION TO DRY EXCEED (3) PER PROJECT, CONTACT ENGINEER OF RECORD AT LEAST 2 HOURS BEFORE PLACING MORTAR. B) ADHERE EXPANSION STRIPS TO JAMBS AND HEAD. MAKE CERTAIN EXPANSION STRIP FOR ADDITIONAL INSTRUCTION. EXTENDS TO SILL. MASONRY WALL. SEE PLAN FOR EXISTING BOND BEAM. C) SET A FULL MORTAR BED JOINT, APPLIED TO SILL. REINFORCING. PROVIDE LOWER D) SET LOWER COURSE OF BLOCK. MAINTAIN A UNIFORM JOINT WIDTH OF 3/8" PLUS OR MINUS HOOKED DOWEL 1/8". ALL MORTAR JOINTS MUST BE FULL AND NOT FURROWED. ALL MORTAR SHALL BE SEE SHEET D2 AND DRILL 3/4"X6" MIN. HOLE TYPE "S" OR "N". STEEL TOOLS MUST NOT BE USED TO TAP BLOCKS INTO POSITION. (PLACE EXPANSION STRIP FLOOR PLAN FOR A RUBBER CRUTCH TIP ON END OF TROWEL TO TAP BLOCK INTO POSITION.) DO NOT 20 ga. PANEL MORE INFO SET BAR IN EPDXY REALIGN, TAP, OR OTHERWISE MOVE BLOCK AFTER INITIAL PLACEMENT. FOR SOLID GLASS ANCHOR HTT16W/(18)-16d NAILSTO CAP TO PREVENT LEAKAGE BLOCK IT MAY BE NECESSARY TO USE WEDGES IN THE MORTAR JOINTS OF THE LOWER "SQUEEZED" W , W , M * AT PERIMETER STUDS & (1) - 5/8" DIA. ALL COURSES TO PREVENT THE MORTAR FROM BEING OUT. 1/4" EXPANSION BOLT (2 WHERE THIS CONDITION #5X6'EMBEDDED INTO E) INSTALL PANEL REINFORCING IN EVERY OTHER MORTAR BED HORIZONTALLY AND IN JOINTS 9 ga. PANEL PER ANCHOR) (1) #5 BARS CONT. OCCURS TOP WITH MIN. 3" THREAD ROD EPDXIED W/ SIMPSON "SET" EPDXY MIN. z EXISTING BOND BEAM IMMEDIATELY ABOVE AND BELOW ALL OPENINGS WITHIN PANELS. (THE SAME SPACING REINFORCING COVER 6-4- 5" EMBEDMENT & 3" MIN. 0 U) SHALL APPLY TO PANEL ANCHORS WHEN USED AT JAMBS AND HEADS IN LIEU OF CHANNEL (EVERY OTHER -F.F. EDGE DISTANCE FILL CELL FULL HEIGHT W1 OR CHASE SURROUNDS.) RUN REINFORCING CONTINUOUSLY FROM END TO END OF PANELS. COURSE) EXPANSION STRIP U- Uj NON SHRINK GROUT. LAP REINFORCING NOT LESS THAN 6 INCHES WHENEVER IT IS NECESSARY TO USE MORE + 0 9 j rA THANONELENGTH. DO NOT BRIDGE EXPANSION JOINTS WITH REINFORCING. INSTALL Uj a- REINFORCING AS FOLLOWS: �.N S EALANT !� co 1 1 u- CL NN4Iii� PLACE LOWER HALF OF MORTAR IN BED JOINT. DO NOT FURROW. L,! M 5X6'EMBEDDED INTO PRESS PANEL REINFORCING INTO PLACE, N ':;.' 6" MIN. LAP SPLICE W/ L) 2� FOOTING 2-#5X6'IN CONIC. COVER PANEL REINFORCING WITH UPPER HALF OF MORTAR BED AND TROWEL REINFORCING PANEL ,,�EEXISTING FILLED CELL SMOOTH. DO NO FURROW. C14 DRILL 3/4"X6" MIN. HOLE F) PLACE FULL MORTAR BED FOR JOINTS NOT REQUIRING PANEL REINFORCING - DO NOT GRADE SET BAR IN EPDXY FURROW. MAINTAIN UNIFORM JOINT WIDTH. 6" MIN. LAP G) SET SUCCEEDING COURSE OF BLOCKS. SPACE AT HEAD OF PANEL AND JAMBS MUST SPLICE NOTE: 04 REMAIN FREE OF MORTAR. H) STRIKE JOINTS SMOOTH WHILE MORTAR IS STILL PLASTIC AND BEFORE FINAL SET. AT THIS SEE GLASS BLOCK INSTALLATION 1�-- NOTES. C14 0 t� TIME RAKE OUT ALL SPACES REQUIRING SEALANT TO A DEPTH EQUAL TO THE WIDTH OF THE SEALANT 61 "�—(2) -'0 SAW CUT SPACES. REMOVE SURPLUS MORTAR FROM FACES OF GLASS BLOCKS AND WIPE DRY. GLASS BLOCK DETAIL #5 REBAR. MIN. 3" TOOL JOINTS SMOOTH AND CONCAVE, BEFORE MORTAR TAKES FINAL SET. (REMOVE WEDGES FROM LOWER COURSES OF SOLID BLOCKS AND POINT THE VOIDS WITH MORTAR.) GLASS BLOCK SHALL BE INSTALLED PER THE FLORIDA BUILDING CODE RESIDENTIAL SECTION R160 16" MIN. COVER EA. WAY SECTION 1) AFTER FINAL MORTAR SET (APPROX. 24 HOURS), INSTALL PACKING TIGHTLY BETWEEN 7r EXISTING FOOTING GLASS BLOCK PANEL AND JAMB AND HEAD CONSTRUCTION. LEAVE SPACE FOR SEALING. SCALE: N.T.S. J) APPLY SEALANT EVENLY TO THE FULL DEPTH OF RECESSES IN ACCORDANCE WITH THE SECTION AT DEEP MONO FOUNDATION RETROFIT FOR MISSING MSTAM STRAP MANUFACTURER'S APPLICATION MANUAL AND INSTRUCTIONS. RETROFIT FILLED CELL DETAIL K) A MAXIMUM OF 60 SQUARE FEET OF GLASS BLOCK MAY BE INSTALLED IN ANY OPENING. SCALE: 3/4" = V-0" SCALE: 3/4" = V-0" FOR WIND SPEEDS UP TO 110 MPH*, PER PITTSBURG CORNING RECOMMENDATIONS FOR SCALE: N.T.S. INSTALLATION OF GLASS BLOCK. 0 (D -L0 z C0 (D Z z (nv) z (D cr) ID03 LU U 0 LLJ V) F- E c) 08 cm, LU E CD n r- ca T.,0 0 04 U-. < 0 cm LO 0 q 9 CL Ci AA III 0 W CN od -JE co LL Z W- 4 - 0;.. Fpt 0 q O.-F 4,vo SS101, To the best of the Q'Aritt on, and belief, the structural plans an."m ined within these drawings comply with the Florida Building Code Sth Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. z 0 1­4 C:) (7) cn U,) M Ln Q) v) L- U— CL 0� U CL 00 z z 3i E z —1 0 W Lu C:) g LU & U U 00 i- Lu 0 Ln z -0 r*.... Lr) 0 U V) U) < LLI g� . Iw- R 6 w a F- LLJ f'4 z z z r-4 U) CO, (5 U. � 6 f5 LU LU x < Lij < z 0 r-4 cc) ql�r T-A Z Z LU CL (A z UA SCALE AS NOTED DATE 2/24/2014 TECH: IFFLORES VERSION No' 10 SHEET NO. SS *DIAGONAL SPACED NOTE: PENDING BEAM AT 15'-0" O.C. MAX BEARING LOCATION, THE ROOF PROVIDE 2X4 MIN. BLOCKING AT 'E "lu SEE SHEATHING Q OF HIP/RIDGE, TYP.BETWEEN AN SHI PLAN TRUSSES W/ (2) 12D NAILS EACH BEAM CAN SIT ON TOP OF COLUMN W/ (2) HTW20 STRAPS FLAYOUT JACK TRUSS (AS SHOWN) OR GABLE END SEE TRUSS END TO TRUSS TOP CHORD 2X4 BLOCKING TYP. ,—CLIP EACH TRUSS BETWEEN TRUSSES TRUSS (2) 2x8 #2 SYP W/ (SEE ROOF PLAN BLOCKING A 7/16" O.S.B. FLITCH BUCKET TO COLUMN FOR TYPE) SECT. A -A PLATE TOP @ TRUSS FRAME OUT TO BRG. SUPPORT COLUMN BUILT-UP BLOCK EDGE A (2)-2x4's OR 4x4 W/ (2)-1 Od G.T. NAILS @ 8 O.C. EACH PLY ----SEE DETAIL 4/D1 ADD 2X4 ALONGSIDE (SHOWN AS 4 x 4) FOR BEAM SIZE TOP CHORD WHEN REQ'D , 1,,� (2) USP HTA20's EXTERIOR SHEATHING ATTACHED PER NAILING TO PREVENT PLYWOOD SPAN FROM EXCEEDING ACK TYPICAL BLOCK w/(l 0)- 1 Old x 1 1/2 EA. TO COL. SCHEDULE 2x SPF #2 MAX 24" SPAN (EITHER �RUSSES lip WALL ALT: (2) USP MSTAM36 AT 16" O.C. SIDE OR BOTH IF REQ'D) oo G.T STRAPS CENTERED w/(l 3)-1 Od NAILS Ea TO COL. CONTINUOUS LATERAL BRACING- TIE BEAM ___�—BUILDER FRAME NAIL OVER X-BRACE AS SHOWN- 4 —IV RADIUS AS REQUIRED INSTALL BLKG. AT TRUSS WEBS (2) 12D NAILS FOR NAILING AT 12" O.C. MAX X-BRACING - 2x4 SPF OR SYP w/ 2-16d @ EACH TRUSS WEB BEAM @ RAISED ENTRY CROSS BRACING DETAIL JYP.)K'�,� HIP/RIDGE BLOCKING DETAIL MASONRY WALL r4 KNEEWALL @ ENTRY FRONT WALL SCALE: 1/2" = V-0" SCALE: 1/2"=V-0" SCALE: 1/2" = V-0" SCALE: 1/2" V-0' TRUSS NOTES: TYP. HAND FRAMING ABOVE TRUSS 1 . WOOD TRUSS ERECTOR SHALL PROVIDE BRACING ACCORDING TO ANSI/TP1-2002 CONV. FRAMED RIDGE 2X4 STUDS & PLATES AT 2'-0" O.C. MAY BE NAILED EACH DIRECTION TYP. U.N.O. USP LSTA18 (TRUSS PLATE INSTITUTE) NOTE THAT THE COMBINED WIND AREA IS GREATER VERTICAL SCAB w/ MIN. (4) 12d WHEN CENTERED @ USP HD4101F BUCKET kSEE PLAN BEFORE THE ROOF SHEATHING IS APPLIED, AND BRACING SHALL THEREFORE BE IT LANDS NEXT TO 2 x 6 #2 SPF 48" O.C. W/ (4) 1 Od TOP & SPLIT TO TIE SEE ROOF PLAN FOR BEAMS TOGETHER MORE I NFO FOR CANT.1 INSTALLED AS THE TRUSSES ARE ERECTED. INADEQUATE BRACING IS THE MOST COMMON CAUSE OF ACCIDENT IN WOOD TRUSS CONSTRUCTION. FULL BUNDLES PRE-ENG. TRUSS 2x8 BLKING. NAILED @ EACH BOTTOM OR USP RT7 OF PLYWOOD SHALL NOT BE PLACED ON TRUSSES. THIS CONSTRUCTION LOAD SIDE w/ (3) 12d NAILS WHEN OR HCLR/LL W/ 8 - 8d SHOULD BE LIMITED TO 8 SHEETS OF PLYWOOD ON ANY PAIR OF TRUSSES & REQUIRED w/ (2) USP HTW20 IN PLACE OF (4) 10d SHALL BE LOCATED ADJACENT TO THE SUPPORTS. NO EXCESS CONCENTRATION W/ (14) - 1 Od X 1 1/2" EACH —SEE FLOOR PLAN FOR OF ANY CONSTRUCTION MATERIAL (SUCH AS GRAVEL OR SHINGLES) SHALL BE PLACED COLUMN SIZE& BASE SEE FLOOR PLAN CONNECTION INFO OSB FLITCH PLATE REQ'D ONLY WHEN ON THE TRUSSES IN ANY ONE AREA THEY SHALL BE SPREAD OUT EVENLY OVER A LARGE AREA SO AS TO AVOID OVERLOADING ANY ONE TRUSS. A;/ � . \� --I /-- COLLAR TIE FOR COLUMN SIZE & ADDITIONAL INFO. ____---7/16" INDICATED ON BM. 2x4 #2 SYP NAILER. NAIL 2. ALL BRACING (DB,CB,BB) SHOWN ABOVE SHALL BE IN ADDITION TO CONTINUOUS EVERY 3rd RAFTER OSI3 FLITCH PLATE SEE FLOOR PLAN FO R SCHEDULE/PLAN TO STUDS w/3-16d @ LATERAL BRACING SPECIFIED BY THE TRUSS MANUFACTER ALL LATERAL BRACING SPECIFIED BY TRUSS MANUF. SHALL HAVE ADDITIONAL DIAGONAL BRACES AT 201-0" REQ'D ONLY WHEN INDICATED ON BM. OPTION A COLUMN SIZE& BA CONNECTION INFO SEJ OPTION B OPTION C. EA. STUD. TOENAIL EA. TRUSS TO NAILER w/3-1 Od ROOF AND EXTERIOR O.C. MAXIMUM. 2x4 SPF 2 SCHEDULE/PLAN SHEATHING ATTACHED 3. ALL BRACES SHALL BE 2X4 NOMINAL DIMENSION LUMBER & SHALL BE ATTACHED W/ 2-16D (2) #7X 3-1/2" WOOD PER NAILING SCHEDULE NAILS AT EACH TRUSS INTERSECTION. SCREW EACH TRUSS COMMON BM. TO POST ATTACHMENT �'�A SEE 2ND FLOOR WALL SECTION 4. ADDITIONAL BOTTOM CHORD BRACING SHALL BE INSTALLED AS REQUIRED BY TRUSS OR USP RT7 @ 48" O.C. 14 FOR ADDITIONAL INFORMATION DESIGN WHEREVER ADEQUATE STRUCTURAL CEILING ARE NOT B SEE ROOF PLAN SCALE: 3/4"=V-0" ATTACHED DIRECTLY TO THE BOTTOM CHORD OF THE TRUSS. DB B—X FOR BEAM SIZE & BM. SPLICE OVER 5. PROVIDE TRUSS BLOCKING AT ALL TRUSS BEARING SUPPORTS WHERE TRUSS 1 7 -- BEVEL CUTS CONNECTION INFO. F CENTER OF POST DEPTH EXCEEDS STANDARD HEEL HEIGHT. SEE TYP. TRUSS BLOCKING DETAILS PRE -ENG.TRUSS (OPTIONAL) A A 2X4 BLOCKING SEE PLAN FOR Ah --- -- -------- 2X4 DIAGONAL AT F-O" O.C. BETWEEN EA. TRUSS CONT. ROOF SHEATHING AT TRUSS TO P TOP OF 8 E�_A_M �V MAX & EACH END ALTERNATE CHORD AT ALL HAND FRAMED AREAS TYP. DIRECTION TYP. A DIAGONAL----, 2x8 #2 SPF RIDGE BEAM AT 8'-0" �—WOOD MAX TRUSS 2x6 #2 SYP RAFTERS FOR SPANS 4FT USP ST1 8 \--SEE TO 8FT 2X4 RAFTERS FOR SPANS LESS TYP. U.N.O. PLAN FOR TYP. U.N.O. THAN 4FT @ 2'-O"O.C. MAX. w/ (3) 1 Od SEE FLOOR PLAN FOR CANT. IF INDICATED USP JU26 OR IF 2 PLY COMMON TOENAILS TO RIDE BEAM COLUMN SIZE & TRUSS USP JUS26-2 SEE FLOOR FRAMING ADDITIONAL INFO. TRUSS TO LEDGER 2X4 CONT. AT—/ CONC.MASO'NRY (WOOD COLUMN SHOWN) 2X8 #2 SYP CONT. LEDGER W/ PLAN AND J/S6 FOR MORE T & B CHORD STEEL OR WOOD MIDDLE (4) 16d NAILS ATTACH NAILS INFO. VERIFY WITH PLAN BEARING SUPPORT INTO END OF EACH FLOOR FOR LOCATION AND TRUSS, 24" O.C. MAX. (AT DIRECTION (IF PARALLE A -A ALTERNATE BLOCKING EACH SIDE OF G.T. INSTALL NAILS EACH SIDE) SEE 2/D2 FOR BLOCKING INFO) CORNER SEE FOUNDATION (4) DETAIL @ INTERIOR BEARING PLAN FOR MORE INFO MASONRY WALL (TYPICAL) ---------ZWOOD SCALE: 1/2" V-0" COMMON BM. ATTACHMENT TRUSS -J A PROVIDE BLOCKING AT ALL TRUSS BEARING SCALE: 3/4"=V-0" SECTION AT LOW ROOF SUPPORT WHERE TRUSS DEPTH EXCEEDS TYP. WOOD TRUSS BLOCKING DETAIL STANDARD HEEL HEIGHT SCALE: 1/2" V-0" SCALE: 1/2"=V-0" VARIES ROOF SHEATHING ATTACHED PER SEE 1/S5 FOR SEE PLAN FOR ADDITIONAL VALLEY TRUSS 2x STUDS @ 16" O.C. W/ USP SPT22 @ BASE & SPT24 @ TOP 8d NAILS AT 2x4 #2 SPF BRACING @ NAILING SCHEDULE 16" O.C. W/ (4) 12d COMMON TRUSSES. EXTERIOR SHEATHING ATTACHED PER OUTLOOKER 4" INFO. O.C. INFO. 2x BLOCKING BETWEEN STUDS TO TRUSS W/ (2) TOENAILS TO TOP 7 12d TOENAILS EACH END STRUCTURAL SHEATHING SEE TRUSS PLAN PLATE & (2) 12d END ----------- —MIN. (2) 2x4 FOR CONNECTION NAILS TO TRUSS INFORMATION. SPFTOP 2x4 STUDS W/ USP NAILING SCHEDULE SPT22 @ BASE SEE J/S6 FOR MORE GABLE (BETWEEN TRUSSES (2) 12d NAILS TO EACH ATTACHED PER NAILING CHORD LOW ROOF/WAL VERTIVAL STUD) BOTTOM PLATE INFO. TRUSS SCHEDULE 1 4VARIES SEE PLAN -7 SHEATHING ATTACHE 2x BASE PLATE W/ (2) 12d PER NAILING SCHEDULE NAILS @ 16" O.C. ALONG W/ gb VARIES W/ FOR WALL LOCATION 2X4 BASE PLATE W/ 1/2" PLYWOOD USP MTW12 TO BLOCKING `-F ROOF SLOPE USP LSTA30 OR MTW12 TO FLOOR (2) 16d NAILS TO BELOW @ 16" O.C. WOOD WALL—\ OR TRUSS. �-2X4 CONT. W/ (2) MIN. 2x4 #2 SPF STUDS @ --y A 16" O.C. W/ EXTERIOR GIRDER BELOW @ 16" O.C. EACH COMMON TRUSS/ FRAMING TYP TOP & BOTTOM SEE PLAN 16d COMMONS SHEATHING ATTACHED NAILS EACH T 7PLYWOOD STUD TYP. T&B TRUSS OR PER NAILING SCHEDULE & (3) 12d TOENAILS TO SEE PLAN FOR PLATE BELOW z MASONRY WALL A --MASONRY WALL BELOW: USP HTAII 6 @ 4'-0" O.C. TO GABLE TRUSS BEAM BELOW: USP FLOORING ROOF SYSTEM TOP OF WALL . ..: MIN. 2X4 #2 SYP P.T. PLATE 16" FLOOR SYSTEM FLOOR GIRDER OR BEAM SEE TRUSS PLAN HTW20 @ 4'-0" O.C. TO GABLE TRUSS —W/— 4 tb W/ 1/2"X8" EPDXY ANCHOR MASONRY WALL SEE @ 3" FROM EACH END & SEE PLAN FOR SEE PLAN FOR DIRECTION CONNECTION A COMMON TRUSS SEE ROOF PLAN LOW ROOF TRU& :5) RAISED BOTTOM CHORD 2x6 BLOCKING UNDER FLOOR G.T. 2nd FLOOR WALL W/ USP SEE PLAN v PLAN FOR MORE 16" O.C. MAX. FOR CONNECTION EXTENSION SEE TRUSS JUS24-2 EACH END SHEAR TRANSFER INFO. SECTION @ FLOOR MANUF. SPEC'S FOR CONNECTIONS TO G.T. EXTERIOR. WALL SECTION @ ENTRY (8 CONNECTION r22NN� SECTION AT HIP GABLE SECTION @ BUMP OUT(39"� SCALE: 3/4" = V-0" SCALE: 3/4" = V-0" SCALE: 3/4"= 11-01. SCALE: 3/4" = 1'-0" SCALE: 3/4"=V-0" DETAILS & SECTIO 'Ps 0 zM 13 z z Z 4--J uj 0 LU l­ E V) Ln 0 2 cn LU E 8 C14 Cn C', 0 co c) 12 :S cco, v 0 0 0 i-S U. CD M,6�� 0 -, r- CO CL 0 < 0 uj ov 8 D. Cj c" CO U'� N z ON S� lb U, .0V 0� 0. U 21 94, .cm L ? ....... -inf bN To the best of th i7s VnMdj�, and prbelief, the t.ied ;'Morlda within these drawings comply Building Code Sth Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. 0 Z C"4 0 (1) r�, �-4 4.j C:) Lf) * 5 1.0 0 > 0-4 V) ry) 0 U-) M Lr) a) _0 U-) C LL zF- CL �-- M 04 U v-4 0_ < 00 z § E z LU c) C) W %0 uj z Z.- z 1L a. uj < ,j z ow Q -z � �zj z W Y M!i C/) :7— F- � z L0 0 Z 0 -0 ra Ln U) 0 > 06 Cn < U8 tg§ F— LLj < < Z ('*4 z Uj r-4 Ln Cyu_� 66 < < z r-4 z Z t_U co 0 r� :5 LU rn . V-4 '0. 1 V) I, SCALE AS NOTED DATE 2/24/2014 TECH: FLORES VERSION No' 10 SHEET NO. D1 (2)- 12d GABLE END FLOOR SEE SS FOR RETROFIT (1) USP LSTA30 STRAPS BENT OVER TOP PLATE TOENAILS 2x4 TO TRUSS TOP TRUSS SEE R/S6 FOR CONNECTION INFO TO CONNECTION IF MSTAM36 CAN NOT BE INSTALLED 1 OR 2 PLY GIRDER THEN DOWN THE FACE USP SPT4 W/ (6)-1 Od X 1 1/2" TRUSS. SEE PLAN FOR OF HEADER/STUDS W/ @ 24" O.C. EXT. SHEATHING MASONRY WALL BELOW AND CONNECTION. (22) 10d NAILS ALT. (2) - 2x SPF TOP PLATE FLUSH W/ TOP 2 /—OF MASNORY & 8d + BLOCKING INFO G) SEE PLAN FOR CONN. 2x CRIPPLES @ 16" O.C. (2) 2x HEADER SEE PLAN SEE FOR BLOCKING NAILS T/B FLANGE 0 1. APPLY SUB (3) 2x # SPF W/ (2) 12d TOENAILS T/B INTERIOR HEADER DETAILS 2xSTUDS + FLOOR + ADHESIVE TO T STUDS w/ 10d @ (2) - 2x SPF TOP PLATE (2) 1 Od TOENAILS AT EA. (1) 2x SILL PLATE W/ (2) 12dTOENAILS. OB 2x4 CONTACT 8" O.C. EACH SIDE END OF SILL. MAX. EXTERIOR HEADERS SURFACE A 2x4 #2 BLOCKING 2' U.N.C. ON PLAN (1) 2x SILL PLATE W/ (2) 12d TOENAILS. FLOOR SYSTEM SEE PLAN NOTE: VERIFY WITH FLOOR FRAMING PLAN FOR I -JOIST B 2x4 SIDE BRACE 2 AT 48" O.C. IF OPENING IS GREATER OPENING LARGER THAN 4 ft (2) 2x THAN 4 FEET BUT NOT SILL PLATE W/ MP3 CLIPS EACH SIDE EXCEEDING 6 FEET. OR FLOOR TRUSS FOR BETWEEN JOISTS 2X CONT. RIBBON A MP3 CLIP IS TO BE MIN (3) 2x #2 SPF STUDS @ END CORRECT BLOCKING w/ (3) 12d EA. END FLOOR DECK INSTALLED AT EA. END OF HEADER SEE Q/S4 FOR REQ'D (2) USP MSTAM36 STRAPS w/ (8) 1 Od G.C. VERIFY INTERIOR 1/2" GYP. BOARD OR EXTERIOR STRUCTURAL REQUIREMENTS I 1-1/8" RIM BOARD TO HORIZ. BLOCKING TYPICAL BLOCK WALL JAMB INFO 2x CRIPPLE AT EA. USP LSTA 30 w/ (11) - 1 Od END OF OPENING TO STUDS ABOVE PLATE NAILS & (5) Y4" x 2 Y4" TAPCONS SHEATHING (MIN. 7/16") FLOOR TRUSS/ NAILED TO STUD CENTERED ON FLOOR SYSTEM TO MASONRY WALL BELOW. CONTRACTOR VERIFY W/ PLAN 8d NAILS @ 3" O.C. WALL SHEATHING JOIST SEE PLAN (2) - 12d TOE NAILS TOP (2) USP MSTAM36 STRAP(S) CENTERED W1 (8) 1 Od NAILS I -JOIST SEE PLAN TIE BEAM PACK w11 Od NAILS FLOOR DECK @ 8"o.c. >—FLOOR TRUSS/ I -JOIST SEE PLAN MAY USE (2) SIMPSON MSTAM36 STRAPS w/ (7) 10d NAILS & (4) Y4" x 2 Y4" TITENST TO RIM BOARD & BOTT. CHORD & (5) 1/4 TAPCONS. USP LSTA30 FROM WINDOW INSTEAD OF USP MSTAM36 STRAPS. IF SCALE: 1 1/2" l'-O" AJS BLOCKING PANEL @ 24" CONTRACTOR MAY USE JAMB TO FLOOR TRUSS/ SOLID WOOD WALL IS BELOW USE (2) MSTA36 SCALE:3/4" 1'- 0" GABLE END RIM JOIS O.C. (MAX) AND @ EACH END OF WALL UNDER SIMPSON (2) MSTAM36 W/ (7) 1 Od NAILS & (4) Y4"xZY4" TAPCONS PROVIDE BLOCKING BELOW JAMBS BLOCKING BELOW. SEE 8/D-2 FOR ALT. CONDITION. DETAIL TO BE STRAPS w/ (22) 1 Od NAILS OR (2) SIMPSON MSTA36 STRAPS w/ (26) 10d SEE SS FOR RETROFIT CONNECTION IF MSTAM36 SEE R/S6 FOR CONNECTION INFO TO CORNERS INSTEAD OF USP STRAP. FOLLOWED IF DOWN SET OR BOX HEADER IS USED NAILS (G.C. TO INSURE SOLID BLOCKING ECTION CORNER CAN NOT BE INSTALLED S MASONRY WALL (2) - 1 Od TOE NAILS EACH SIDE EITHER STRAP IS ADEQUATE OTHERWISE DETAIL CAN BE IGNORED IS INSTALLED). EITHER USP OR SIMPSON STRAPS ARE ADEQUATE FRAMING ATTACHMENT BLOCKING DETAIL GIRDER/COL. CONN. @ 2nd FLOOR HEADER CONN. @ 2nd FLOORr4_'N� SCALE: 1/2" = l'-O" AS NOTED SCALE: 3/4" 1'-0" SCALE: 1/2" 1'-0" SEE Q/S4 FOR USP SPT24 @ EA. STUD W/6-10d SEE SS FOR RETROFIT SEE 8/D-2 FOR ALT. CONDITION. DETAIL TO BE CONNECTION IF MSTAM36 FOLLOWED IF DOWN SET OR BOX HEADER IS USED 2x6 / 2x8 CRIPPLES @ 16" O.C. JAMB STUD USP SPT4 W/ (6)-1 Od X 1 1/2" TO STUD & TO TOP PLATE NOTCHED @ HEADER LOCATION SEE (2) 2x8 OR (2) 2x6 TOP REQ'D TYP-7 @ 24" O.C. USP LSTA24 W/(1 8)-1 Od NAILS CAN NOT BE INSTALLED OTHERWISE DETAIL CAN BE IGNORED INFO BELOW ON CONNECTION OF PLATE SEE PLAN CRIPPLES IF LONGER THAN 8" TALL. T_yP-j 2-2x4SPF USP RS150 W/ MIN. 12" END USP SPT4 W/ (6)-1 Od X 1 1/2 SEE PLAN FOR CONN. (CONTRACTOR MAY USE RTT CLIPS) 2x HEADER TO SIT W TOP PLATES LENGTH ON STUDS W/ (11) 1 Od (1) USP LSTA30 STRAPS BENT @ 24" O.C. NAIL BACK LEG OF CIPPLE TO (2) NAILS TO STUDS ABOVE & (11) 1 Od OVER TOP PLATE THEN DOWN (2) - 2X SPF TOP PLATE HEADER w/ (2) 12 TONEAILS FLUSH W/ THE OUTSIDE NAILS TO STUDS BELOW. THE FACE OF HEADER/ STUDS SEE PLAN FOR SIZE 2 x 4 #2 SPF STUDS C AT 16" O.C. U.N.O. D USP SPT22 W/ (6)-10d TO STUD & @ W/ (22) 1 Od NAILS (2) 2x HEADER SEE PLAN 2x6 / 2x8 WALL BEYOND SEE HEADER FLUSH TO OUTSIDE FLOOR PLAN FOR HEADER NAILING AREA (TYP.) (2) 2x HEADER (4) - 1 Od TO PLATE 5/8" A.B. @ 24" O.C. AND 6" FROM MIN (3) 2x #2 SPF STUDS @ INTERIOR HEADER SEE PLAN FOR COL. SIZE /:(2) CONNECTION SEE PLAN USP MSTA36 STRAPS CENTERED EACH END W/ 7" EMBEDMENT. IF END OF HEADER SEE Q/S4 FOR (1) 2x SILL PLATE W/ (2) 12dTOENAILS. W/ (22) ld NAILS OR (2) SIMPSON DOUBLE 2x6 OR 2x8 TOP SEE STANDARD HEADER AT STEP DOWN LOCATION, MIN 7" XSP F EMBEDMENT PAST STEP, REQ'D JAMB INFO EXTERIOR HEADERS (1) 2x SILL PLATE W/ (2) 12d TOENAILS. MSTA36 STRAPS w/ (26) 1 Od NAILS (EITHER USP OR SIMPSON STRAPS PLATE SEE PLAN CONNECTION DETAILS FOR Z� Xl�." MORE INFORMATION FLOOR SYSTEM OR 12d NAILS AT 6" C B BASE PLATE USP SPT4 EACH STUD PRE-ENGINEERED @ HEADER / JAMB CONDITION FLOOR SYSTEM OR IF BUILT-UP STUDS ARE 2x CRIPPLES @ 16" O.C. _�, W/ (2) 12d TOENAILS T/B OPENING LARGER THAN 4 ft (2) 2x SILL PLATE W/ MP3 CLIPS EACH SIDE (2) - 10d TOENAILS AT EACH END OF 2-STY. FRAMING ARE ADEQUATE) BAND JOIST & BLKG. O.C. TYP T & B USP SPT6 OR (2) 2 x #2 SPT8 @ 24" o.c. SYP WAL OR BEAM W/IN WALL SYSTEM A.B. TO BE SILL (MAX. OPENING WIDTH 4 OR LVL GIRDER U.N.O. SPACED W/IN 6" FROM OPENINGS (2) - 2 x4 SPF 2X CRIPPLE AT EACH END OF FEET). IF OPENING IS GREATER (BLOCK SOLID) j AND MULTIPLE STUD PACKS TOP PLATES OPENING NAILED TO STUD THAN 4 FEET, BUT NOT EXCEEDING 6 FEET, A MP3 CLIP IS TO BE SEE PLAN FOR 2 x CONT. T & B INTERIOR HEADER PACK W/ 10d NAILS @ 8"O.C.— INSTALLED TO EACH END COL. SIZE (1) 2x SILL PLATE W/ (2) 12dTOENAILS. LE 2 x 4 42 SPF STUDS EXTERIOR HEADERS (1) 2x SILL PLATE W/ (2) 12d TOENAILS, TYPICAL BLOCK WALL-------,, PLYWOOD ATTACHED PER NAILING SCHEDULE USP HTT45 BASE W/ AT 16" O.C. U.N.O. (2, z OPENING LARGER THAN 4 ft (2) 2x SILL FLOOR TRUSS/ I -JOIST SEE PLAN (18) 16d NAILS & V8" ANCHOR BOLT W/ BOX HEADER SEE PLAN E P F PLATE W/ MP3 CLIPS EACH SIDE 2 x 4 P.T. STUDS UNDER 2nd FLOOR HEADER USP MSTAM36 STRAP(S) CENTERED W/ (8) 1 Od NAILS TIE BEAM MIN. 6" EMBEDMENT (2) 2x TOP PLATE (2) LSTA1 2 WRAPPED UP D BASE PLATE ARE NOT REQ'D TO HAVE & (5) 1/4 TAPCONS. CONTRACTOR MAY USE PROVIDE BLOCKING AND OVER TOP PLATE x PPLES @ 16" O.C. W/ USP SEE FOUND. PLAN FOR FTG. REQ. CONNECTIONS. ATTACH STUDS w/ (3) 12d TOENAILS T&B SIMPSON MSTAM36 W/ (7) BELOW JAMBS /t- T.-IT— SPT22 & SPT24 (OR SPT4) 1 Od NAILS & (4) Y4114Y4" CONNECTORS @ TOP PROVIDE EXTERIOR SHEATHING TAPCONS INSTEAD OF USP STRAP. EITHER STRAP IS SEE FOUNDATION PLAN PROVIDE (2) CRIPPLES BELOW TO ANY GIRDER TRUSS IN THIS ATTACHED PER NAILING SCHEDULE 2 ST. INT. BEARING WALL ADEQUATE FOR FTG. REQ. 2x CRIPPLES TO SITUATION. CONNECT G.T. TO FOR EXTERIOR 2 STORY WALLS ONLY. MATCHJACK STUDS W/ (2) - HTW20 TOP & (2) AND EXTERIOR SHEATHING CAN STOP ONCE UNDER HEADER CONN. @ 2nd FLOOR STUDS BELOW HTW20 @ BASE TO HEADER 5� LOWER ROOF. 2 STORY COL. GIRDER r7 (IF CRIPLLES ARE LESS THAN SCALE: 1/2" V-0-1 SYSTEM 42 SCALE: 1/2" = V-0" 8" LONG NO STRAPS ARE SCALE: 1/2" V-0" REQ-D) ADDITIONAL STRAPS SEE STANDARD HEADER REQUIRED AT TOP PLATE SEE SS FOR RETROFIT S E 8/D-2 FOR ALT, CONDITION. DETAIL TO BE 1'�CONNECTION DETAILS FOR TO STUDS TO MATCH CONNECTION IF MSTAM36 FOLLOWED IF DOWN SET OR BOX HEADER IS USED MORE INFORMATION HEADER STRAPS CAN NOT BE INSTALLED OTHERWISE DETAIL CAN BE IGNORED (2) LSTA24 (2) 2x HEADER SEE PLAN SEE 8/D-2 FOR ALT. CONDITION. DETAIL TO BE FOLLOWED IF DOWN SET OR BOX HEADER IS USED (2) USP LSTA30 STRAPS US P S PT4 W/ (6)-1 Od X 1 1/2" 2x4 STUD S PER PLAN MIN (3) 2x #2 SPF STUDS @ END OF HEADER OTHERWISE DETAIL CAN BE IGNORED BENT OVER TOP PLATE @ 24" O.C. SEE Q/S4 FOR REQ'D JAMB INFO THEN DOWN THE FACE OF HEADER/STUDS W/ (22) 10d 2) 2x HEADER SEE PLAN DOUBLE 2x4 USP MP3 EACH END TYP. FOR OPENINGS LESS THAN 4'-0" WIDE, (1) USP LSTA30 STRAPS BENT NAILS 2x CRIPPLES @ 16" O.C. TOP PLATE SILL MAY BE ATTACHED W/ (2) - 16d OVER TOP PLATE THEN DOWN US P S PT4 W/ (6)-1 Od X 1 1/2" W/ (2) 12d TOENAILS T/B TOENAILS @ EACH END THE FACE OF HEADER/ STUDS @ 24" O.C. INTERIOR HEADER 2 WS 10d @ (2) 2x SILL PLATE W/ (22) 1 Od NAILS (2) - 2X SPF TOP PLATE MIN (3) 2x #2 SPF STUDS (1) 2x SILL PLATE W/ (2) 12dTOENAILS. WO/ _4'"7�2x (2) 2x HEADER SEE PLAN @END OF HEADER. SEE EXTERIOR HEADERS 2x SILL PLATE W/ 12d TOENAILS. STUDS @ 16" O.C. 2x CRIPPLES @ 16" O.C. W/ (2) 12d TOENAILS T/B INTERIOR HEADER Q/S4 FOR REQ'D JAMB (1) (2) OPENING LARGER THAN 4 ft (2) 2x TOP SPLICE (1) 2x SILL PLATE W/ (2) 12dTOENAILS. INFO. EXTERIOR HEADERS SILL PLATE W/ MP3 CLIPS EACH SIDE (2) - 10d TOENAILS AT EACH END OF SILL (MAX. OPENING, (1) 2x SILL PLATE W/ (2) 12d TOENAILS. THAN 4 ft 2x 2x CRIPPLE AT EACH END OF OPENING NAILED TO STUD (2) - 10d TOENAILS AT EACH END OF SILL (MAX. OPENING WIDTH 4 FEET). ALT. HEADER ANCHOR WIDTH 4 FEET). IF OPENING OPENING LARGER (2) SILL PLATE W/ MP3 CLIPS EACH SIDE PACK W/ 1 Od NAILS IF OPENING IS GREATER THAN 4, r8 IS GREATER THAN 4 FEET FEET BUT NOT EXCEEDING 6 FEET, BUT NOT EXCEEDING 6 FEET, MIN (3) 2x #2 SPF STUDS @ END TYPICAL BLOCK WALL A MP3 CLIP IS TO BE INSTALLED AT PROVIDE 2x4 ON SCALE: N.T.S. A MP3 CLIP IS TO BE INSTALLED AT EACH END OF HEADER SEE Q/S4 FOR EACH END. FLOOR DECK TOP OF 2x8 TO REQ'D JAMB INFO BLOCK OUT TOP 2x CRIPPLE AT EACH USP LSTA30 CENTERED (2) USP MSTAM36 STRAP(S) FLOOR TRUSS/ I -JOIST SEE PLAN PLATE ATTACH END OF OPENING W/(22) 10d NAILS CENTERED W/ (8) 1 Od NAILS 2X CONT. RIBBON W/ (2) 10d NAILS NAILED TO STUD PACK W/ 1 Od NAILS @ 8"o. c. FLOOR DECK & (5) 1/4 TAPCONS. TIE BEAM @ 3" O.C. 2x4 BEYOND DOUBLE CONTRACTOR MAY USE AGAINST 2x8 2x8 TOP FLOOR TRUSS/ I -JOIST SEE PLAN SIMPSON (2) MSTAM36 W/ (7) PROVIDE BLOCKING STUDS PLATE SEE PLAN FOR BEAM 1 Od NAILS & (4) Y4"x2,Y4" BELOW JAMBS 2x8 STUDS 2x4 W/ 2 ROWS SIZE & CONNECTIONS TAPCONS INSTEAD OF USP NOTE: PER PLAN OF 10d NAILS STRAP. EITHER STRAP IS PLATE LENGTHS MUST BE @ 3" O.C. HEADER CONN. 2nd FLOOR ADEQUATE HEADER CONN. @ 2nd AT LEAST 4'-0" LONG. TYPICAL W/ HIGH BM FLOOR [DOUBLE STRAP] TOP PLATE SPLICE DETAIL SCALE: 1/2" = 1 1-011 SYSTEM 42 SCALE: 1/210 = 1'4' SCALE: 3/4" = l'-O" zm 0 0 Z co U) z V) CD C—n (Dm U — 0 LLJ UO E 0 U-) m LU I_ E — 8 co ce) 0 " 10 7S CO, 0 0 , r U 1 00 < 0 cn 8 LC) OS t CL ch < 6 A I 8 D. N, I C..j U-) U, r- 0 ci LU < 13- 60 AAM m G) 4Q IL( FV_ .e r 'tation, and Tothebest %,,ngme�eRi?n'&I belief, t thin Code 5th Edition (2014) Residential. Engineer's signature and sea[ is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. 0 C) Z rj 0 (L) N 1,-4 C:) U-) cc:)) 170 Ln M Ln (n m V- z CA 5 r, < 2 Ln C U. Ce U CL 00 < z Z E ...0 z Uj j CD W �z u, z LLI 0) Z, LOL, iZ U., z a Ln 0 z z 0 "0 N Ln U) 0 od U Cn uj Rgg U-i fn 0 Ly a� C"4 Z z LU Ln Lij di r-4 z 82 CIO T--1 z Z t— U LLJ lu, z 0 9 0 rn lr_� 0- ul SCALE AS NOTED DATE 2/24/2014 TECH: FFLORES VERSION NO 2mO SHEET NO. D2 THESE DETAILS ARE GENERIC AND MEANT TO SHOW GENERAL FLASHING AND WATERPROOFING METHODS TO BE USED. WEATHER RESISITIVE BARRIER HEAD FLASHING TIE-IN INSTRUXTIONS: 1. Cut, fold up & temporarily secure weat barrier above header to allow for flashing installation 2. Self -adhered flashing plus head flashing under weather resistive barrier 3. Fold weather resistive barrier back over head flashing and seal with tape SELF -ADHERED FLASHING Scale: NTS FLANGED WINDOW FLASHING INSTALLATION AFTER WEATHER RESISTIVE BARRIER EXTERIOR SHEATHING �v REFER TO TECHNICAL LETTER ON CHEMICAL COMPATIBILITY SELF -ADHERED FLASHING DO NOT FLASH OVER BOTTOM NAILING FLANGE NOT USED SELF -ADHERED FLASHING HALF ROUND WINDOW SELF -ADHERED FLASHING DECK JOIST ''n WEATHER VE BARRIER & tARILY SECURE WEATHER RESISTIVE BARRIER DOOR ROUGH OPENING WOOD FRAME CONSTR. EXTERIOR SELF -ADHERED FLASHING 3/4"-V BEAD OF CONSTR. SHEATHING BY LAPPING DOWN I ADHESIVE TO BE APPLIED UNDER OVER RIM JOIST AND Up THRESHOLD OF DOOR AND RETURN WALL BY 6 IN. UP JAMB 6". USE LIQUID NAIL BRAND OR EQUAL WEATHER PROOF CAULKING @ WEATHER SELF -ADHERED FLASHING RESISITIVE BARRIER SEAL TOPS OF JOISTS UNDER DECKING SUBFLOOR (SEE DETAIL WP07) ED FLASHING SELF -ADHERED FLASHING SELF -ADHERED FLASHING EXTERIOR DOOR WITH DECK - SECTION A EXTERIOR SHEATHING 3/4"-l"BEAD OF CONSTR. ADHESIVE TO BE APPLIED UNDER THRESHOLD OF DOOR AND RETURN UP JAMB 6". USE LIQUID NAIL BRAND OR EQUAL WEATHER PROOF CAULKING -A (SEE DETAIL WP02) SECTION SELF -ADHERED FLASHING SEAL TOPS OF JOISTS UNDER DECKING (SEE DETAIL WP07) SELF-ADHER Q SELF -ADHERED FLASHING EXTERIOR DOOR WITH DECK SELF -ADHERED FLASHING OUTSIDE CORNER NOT USED RIM JOIST INSTALL SELF -ADHERED FLASHING JAMB & HEAD FLASHING, SEE FLANGED WINDOW (SEE DETAIL WP01) SELF -ADHERED FLASHING, EXTEND A MINIMUM 6" VERTICALLY FROM BOTTOM OF THRESHOLD SELF -ADHERED FLASHING PATCH HERED FLASHING 1 2 4 5 WINDOW UNIT SLOPE 0.3 in: 12.0 in (0. 6 cm : 30.5 cm) SELF -ADHERED FLASHING EXTERIOR CEMT. FIN. BUILDING PAPER WIRE LATH V Q SELF -ADHERED FLASHING CEMT. FINISH SILL/ POTSHELF/ CHIMNEY SHOULDER MECHANICALLY FASTEN IF NEEDED IN CORNERS THROUGH SELF -ADHERED FLASHING RUBBERIZED ASPHALT RUBBERIZED ADHESIVE ASPHALT ADHESIVE SELF -ADHERED FLASHING F_ SELF -ADHERED FLASHING INSIDE CORNER Ground FOUNDATION WEEP SCREED NOT USED SCORED RELEASE P1 PER (BEFORE FOLDING, SCORE RELEASE PAPER TO EXPOSE ADHESIVE AS SHOWN) Water Resistant Barrier Lath Sheathing Stucco FLASHING REQUIREMENTS R612.10 Flashing, Sealants and Weatherstripping, Flashing and sealants for exterior windows shall comply with Section R703.8 R703.2 Weather -resistant sheathing paper. One layer of No. 15 asphalt felt, free from holes and breaks, complying with ASTM D 226 for Type 1 felt or other approved water -resistive barrier shall be applied over studs or sheathing of all exterior walls. Such felt or material shall be applied horizontally, with the upper layer lapped over the lower layer not less than 2 inches (51 mm). Where joints occur, felt shall be lapped not less than 6 inches (152 mm). The felt or other approved material shall be continuous to the top of walls and terminated at penetrations and building appendages in a manner to meet the requirements of the exterior wall envelope as described in Section R703.1 Exception: Omission of the water -resistive barrier is permitted in the following situations: 1. In detached accessory buildings. 2. Under exterior wall finish materials as permitted in Table R703.4 3. Under Paperbacked stucco lath when the paper backing is an approved water -resistive barrier. R703.8 Flashing. Approved corrosion -resistant flashing shall be applied shingle -fashion in a manner to prevent entry of water into thewall cavity or penetration ofwater to the building structural framing components. Self -adhered membranes used as flashing shall comply with AAMA 711. The flashing shall extend to the surface of the exterior wall finish. Approved corrosion -resistant flashings shall be installed at all of the following locations: 1. Exterior window and door openings. Flashing at exterior window and door openings shall extend to the surface ot he exterior wall finish or to the water -resistive barrier for subsequent drainage. Flashing at exterior window and door openings shall be installed in accordance with one or more ofthe following or other approved method: 1.1 The fenestration manufacturer's written flashing instructions. 1.2 The flashing manufacturer's written installation instructions. 1.3 In accordance with FMA/AAMA 100, FMA/AAMA 200, or FMA/WDMA 250. 1.4 In accordance with the flashing method of a registered design professional. 2. At the intersection of chimneys or other masonry construction with frame or stucco walls, with projecting lips on both sides under stucco copings. 3. Under and at the ends of masonry, wood or metal copings and sills. 4. Continuously above all projecting wood trim. 5. Where exterior porches, decks or stairs attach to a wall or floor assembly of wood -frame construction. 6. At wall and roof intersections. 7. At built-in gutters. R703.6.2.1 Weep Screeds A Minimum 0.01 9-inch (No. 26 GaIv. sheet gage), corrosion -resistant weep screed or plastic weep screed, with a minimum vertical attachment flange of 3 1/2" shall be provided at or below the foundation plate line on exterior stud walls in accordance with ASTM C 926. SELF -ADHERED FLASHING PRODUCTS DETAILS TWO LAYERS OF FELT OR ONE LAYER OF HOUSE WRAP AND ONE LAYER OF FELT ARE REQUIRED BEHIND STUCCO. FBC R703.2.1 Detail Instructions as(Din each detail that corresponds to the numbered items in the list of Refer to the number marked instructions below: 1 . Install self -adhered flashing in order as shown by numbers 2. Install flashing and weather resistive barrier to form water shedding laps 3. Self; -adhered flashing can be substituted for building paper 4. Split the release paper using the ripcord (Split release on demand, embedded in the adhesive layer) - for ease of installation and to minimize scoring cuts 5. Remove all release paper per standard installation instructions and adhere to substrate using a square piece of flashing material (6" x 6" Minimum) 6. Fold as shown by arrows 7. Angle of corner may vary, adjust folding of the flashing accordingly to fit tight to corner 8. Mechanically fasten as necessary Cement Plaster in accordance with ASTMC926 over wood 2nd floor Cement Plaster over block 1 st floor 7/8" Cement Plaster in accordance with ASTMC926 Felt backed metal lathe in accordance with ASTMC 1063 Building Paper -7/16" O.S.B. sheathing Metal Flashing Weep Screed Installed As Per Manufact. Specs. Maintain Bottom of Weep Screed 1 1/2" to 21' Above Roof Sheathing Note: The building paper and metal lath must be installed over the top of the weep screed. /*001\ WEEP SCREED DETAIL SCALE: NOT TO SCALE 7/8" Cement Plaster -Starnpede or similar cauk bottom joint only Weep Screed Installed As Per Manufact. Specs. 1/2" Cementitious Decorative Finish All inside and outside comer will need to be miter cut and caulked all butt joints needto becaulked using Stampede or sim. caulk for all 0 LID (D Z co < a) Z C1 U) Z C V) (D Q) C_/� 4--J LU 0 LU - V) Ct -a)U ZD E 0 22 L/) .2 r­ N LU E 8 M a). Cn C C', 2 'S cn, 0.2,, 4i ul % LL 6 $ co -,e 0. CD 01- - < 0 0) 0 ci A jg-[ RD. 8 _' D. N 1: 11 D C C:�, ii cl� �2 1�- C'4 Z sm ,.N* C5 c", C c', W 4F E -, 0 V, , M co U_ LL_ UJ LLJ .9 L , L , 8 a CL - :5 2f i Z 0 -S -. S � J. t) W 0 W cc co Z0 8 LL W < C%1 _J M C X LU < ce 0 0 M F- To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code 5th Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. C) C:) Z N 0 Q) r-, 1-­1 4-J V) - =) > Ln ro a 4 C) U-) M In Z cn 0 N (L) - Ln g " LL, (D � cle >. M U C�. 00 Z < . E Z �: ro C:) F- WLU _J C) Z g X 0 0 UJ Raw Z cl) 0 Ln 0 al Z 8 0 In LL1 0 Z -0 Ln UL. 0 4 > r'q 0 0 uJ U LU is 1-, 0 8 4 I se P 86 < :W C-4 N 3. U4 a�::I V � � W < Z Z LU (%4 L0 _J LU 8 C%4 Z Z Z t Z C0 C) UJI 0 <171 Z W rn T-4 SCALE AS NOTED DATE 2/24/2014 TECH: FFLORES VERSION NO 10 SHEET NO. W P LJSP Connectots Closs Refcwm�e USP Florida Statewicic Evaluation Repoit Sillip-,oll Floii(M Stalewi(W EVaklatl0l) P01)01t CD Stock No Pioduct Appioval No Basis Stock No Piodtj(A Appioval No Ba'Is C5 A3 FL17244.1 ESR-3455 A23 FL10446.2 ESR-2606 HD210-2 FL17232.3 Cn ESR-3445 HU210-2 FL10656.20 ESR-2549 -cu C/) HD212-2 FL17232.3 ESR-3445 HU212-2 FL10655.23 ESR-2549 CD HD216 FL17232.3 ESR-3445 HU216 FL10655.29 ESR-2549 2 W 0 0 HD216-3 FL17232.3 ESR-3"5 HU216-3 FL10655.29 ESR-2549 PRODUCT APPROVAL SPECIFICATION SHEET C) HD26 FL17232.2 ESR-3445 HU26 FL10655.31 ESR-2549 As required by Florida Statute 553.642 and Florida Administrative Code 9B-72, please provide the information and approval numbers on the building components listed below If they will be utilized on the construction project for which you are applying for a building permit. We recommend you contact your local product supplier should you not know the C) HD28-2 FL17232.3 ESR-3445 HU28-2 FL10655.34 ESR-2549 product approval number for any of the applicable listed products. M (:) > (/)-0 E 0 HD410 FL17232.4 ESR-3"5 HU410 FL10655." ESR-2549 L_ 0) L_ 0- HD412 FL17232.4 ESR-3445 HU412 FL10655.45 ESR-2549 Categ0rY1Subc&t9g0rY Manufacturer Product Description Approval Number(s) Test Pressures Cn C:)- HD610 FL17232.4 ESR-3445 HU610 FL10655.51 ESR-2549 - ICU H00410 FL17241.5 ESR-3444 HUCQ410 FL11468.11 SIM200804 1. EXTERIOR DOORS HGA10KT FL17236.6 ESR-3448 HGA10KT FL1 1470.4 SIM200803 A. SWINGING ThermaTru Smooth -Star and Benchmark FL15225.5 +67.0/-67.0 psf ThermaTru Premium, Construction Series and Benchmark FL15225.6 +47.0/-47.0 psf HGAMIOKT FL17699.1 Evaluation Report HGAM10KT FL1 1470.4 SIM200803 HHCP2 FL17236.7 ESR-3448 HCP2 FL10"7.2 ESR-2551 ThermaTru Fiber Classic / Smooth Star FL15000.1 +55.0/-55.0 psf HTA16 FL17680.2 Evaluation Report HETA16 FL1 1473.5 SIM200802 B. SLIDING General Aluminum Company Series 4201430 FLI 5332.1 - FL1 5332.5 +40.0/-40.0 psf HTA20-18 FL17680.2 Evaluation Report HETA20 FL1 1473.5 SIM2OD802 C. SECTIONAL Clopay Building Products Residential WIndCode Doors W5 (8X7) FL15279.37 +30.002.0 psf HTT16 FL17324.1 Evaluation Report HTT16 FL1 1496.1 ES-0130 Clopay Building Products Residential WindCode Doors W5 (16X7) FL15279.53 +30.000.0 psf HTT45 FL17324.1 Evaluation Report HTT22 FLI 1496.1 ES-0130 . lopay Building Products Residential W1ndCode Doors W8 (8X7) FL15279.85 +38.0/-42.0 psf HTT4 FL17219.2 ER-0200 HTS16 FL10456.22 ESR-2613 Clopay Building Products Residential WIndCode Doors W6 (16X7) FL15279.102 +37.0/-41.0 psf HTT5 FL17219.2 ER-0200 HTS20 FL10456.23 ESR-2613 D. METAL LOUVERED DRS Curries Division of AADG, Inc 607,707,727,747,and 847 Single & Pairs of Doors FL1 1537.1 N/A (see inst sht) HTWIS FL17244.8 ESR-3455 HTS24 FL10456.24 ESR-2613 HTVV20 FL17244.8 ESR-3465 HTS30 FL10456.26 ESR-2613 2. WINDOWS HTW24 FL17244.8 ESR-3455 HTSM16 FL11473.11 SIM200802 A. SINGLE HUNG General Aluminum Company Series 1550/1570 FL1 5217.4 - FL1 5217.5 +50.0/-65.0 psf HTW30 FL17244.8 ESR-3455 HTSM20 FL11473.11 SIM200802 General Aluminum Company Series 1900/1970 FL15217.7 - FL15217.9 +40.0/-50.0 pat HTWM16 FL6223.2 Evaluation Report HGT2 FLID466.18 ESR-2613 B. HORIZONTAL SLIDER General Aluminum Company Series 1580/1590 FL15288.1 - FL15288.2 +40.0/-50.0 psf HTWM20 FL6223.2 Evaluation Report HGT3 FL10466.19 ESR-2613 General Aluminum Company Series 1980/1990 FL15288.3 - FL15288.4 +40.0/-50.0 psf HUGT2 FL6223.3 Evaluation Report HUS210-2 FL10655.92 ESR-2549 C. FIXED General Aluminum Company Series 1560/1570 FL15278.4 - FL15278.5 +40.0/-40.0 psf HUGT3 FL6223.3 Evaluation Report HUS212-2 FL10655.93 ESR-2549 General Aluminum Company Series 1900/1970 FL15278.7 - FL15278.9 +40.0/-50.0 psf HUS210-2 FL17232.7 ESR-3445 HUS26 FL10665.94 ESR-2549 D. MULLION General Aluminum Company 1445, 5347 and 5547 Vertical Mullion FL15333.7 N/A HUS212-2 FL17232.7 ESR-3445 HUS28 FL10655.96 ESR-2549 E. OTHER Z HUS26 FL17232.7 ESR-3445 HUS28-2 FL10655.97 ESR-2649 HUS28 FL17232.7 ESR-3445 LU24 FL10655.103 ESR-2549 3. PANEL WALL HUS28-2 FL17232.7 ESR-3445 LU26 FL10655.104 ESR-2549 A. SIDING James Hardie Building Prod. Camplank Lap Siding and HardiePlank Lap Siding FL1 3192.1 - FLI 3192.2 N/A JL24 FL17232.8 ESR-3445 LUS210-2 FL10655.107 ESR-2549 B. SOFFITS Alside Solid and Vented Soffit FL15272.1 - FL15272.2 +70.0/-70.0 psf W JL26 FL17232.8 ESR-3445 LUS24 FL10655.109 ESR-2549 C. OTHER JUS210-2 FL17232.12 ESR-3445 LUS26 FL10655.111 ESR-2549 - JUS24 FL17232.11 ESR-3445 LUS26-2 FL10655.112 ESR-2549 JUS26 FL17232.12 ESR-U45 LUS28 FL10655.113 ESR-2649 4. ROOFING PRODUCTS JUS26-2 FL17232.12 ESR-3445 LUS46 FL10655.118 ESR-2549 A. ASPHALT SHINGLES Certain Teed Corporation CT20 (and AR), Landmark 30/40 (and AR), FL5444.1 N/A JUS28 FL17232.12 ESR-3445 LEG3 FL10667.71 ESR-2615 XT25 (and AR), XT30 (and AR) JUS46 FL17232.12 ESR-3445 MST60 FL10852.7 ESR-2105 B. UNDERLAYMENTS Tamko 151b Felt Underlayment FL12328.6 NIA KLEG3 FL17241.15 ESR-3444 LSTA12 FL10852.4 ESR-21 05 HomeGuard Building Products, Inc ToughSkin Synthethic Underlayments FL21675.1 N/A KST260 FL17244.15 ESR-3455 LSTA15 FL10852.4 ESR-2105 C. ROOFING FASTENERS NOT USED LSTA12 FL17244.18 ESR-3455 LSTA18 FL10852.4 ESR-21 05 D. ROOF VENTILATORS Thompson Arch Metal Comp. Off Ridge Vents FL5219.1 - FL5219.3 N/A LSTA15 FL17244.18 ESR-3455 LSTA24 FL10852.4 ESR-21 05 Florida Metal Products, Inc Vent RV10 FL2075.1 N/A LSTA18 FL17244.18 ESR-3455 LSTA30 FL10852.4 ESR-21 05 Lomanco, Inc DA-4 Exahust Vent FL17202.1 N/A LSTA24 FL17244.18 ESR-3455 LSTA36 FL10852.5 ESR-2105 O'Hagin Manufacturing, LLC O'Hagin's Cloakded Vent Tile FL16588.1 N/A LSTA30 FL17244.18 ESR-3455 LTT19 FL1 1496.3 ER-130 E. ROOFING TILES Boral Tile Villa 900 FL7849.24 - FL7849.26 N/A LSTA36 FL17244.18 ESR-3465 LTT20B FLI 1496.3 ER-130 Boral Tile Saxony 900 FL7849.13 - FL7849.16 N/A LTS19 FL17219.3 ER-0200 LTT131 FL1 1496.3 ER-130 F. OTHER LTS20B FL17219.3 ER-0200 LTS12 FL10456.29 ESR-2613 5. SHUTTERS LTT131 FL17219.3 ER-0200 LGT2 FLI 1470.7 SIM200803 A. STORM PANELS Global Protection Products Galvanized Steel Storm Panels FL15076.1 - FL15076.2 N/A LTW12 FL17244.8 ESR-3465 LS30 FL10446.15 ESR-2606 Global Protection Products GPP Fabric Shutter Series 2000 FL15088.1 N/A LUGT2 FL17240.2 ESR-3447 A34 FL10446.3 ESR-2606 Town and Country Industries Safety Edge Storm Panels FL12856.1 +54.0/-54.0 psf MP3 FL17244.22 ESR-3455 LTP4 FL10446.19 ESR-2606 All American Shutters Galvanized Steel Storm Panels FL17869.1 N/A MP34 FL17244.23 ESR-3455 LS50 FL10446.16 ESR-2606 6. STRUCTURAL MP4F FL17244.24 ESR-3455 WM1416 FL10667.86 ESR-2615 COMPONENTS MP5 FL17244.22 ESR-3455 MSTA12 FL10852.8 ESR-2105 A. WOOD CONNECTORS/ USP Structural Conn. see chart MPH3516 FL17240.3 ESR-3447 MSTA15 FL10852.8 ESR-2105 ANCHORS Simpson Strong -Tie see chart MSTA12 FL17244.18 ESR-3455 MSTA18 FL10852.9 ESR-2105 B. TRUSS PLATES ITW Building Components Alpine Truss Plates FL1999.1 - FL1999.4 N/A MSTA15 FL17244.18 ESR-3455 MSTA24 FL10852.9 ESR-2105 MiTek Industries, Inc. Truss Plates FL2197.1 - FL2197.5 N/A MSTA18 FL17244.18 ESR-3455 MSTA36 FL10862.9 ESR-2105 C. ENGINEERED LUMBER Boise Eng. Wood Prod. Versa -Lam SP FLIS".1 N/A MSTA24 FL17244.18 ESR-3455 MSTC40 FL10852.11 ESR-2105 Boise Eng. Wood Prod. Wood I -Joists ALLJOIST FL1645.1 N/A MSTA36 FL17244.18 ESR-3455 MSTC52 FL10852.11 ESR-21 05 Weyerhaeuser Engineered lumber - TJI FL1 630.1 - FLI 630.11 N/A MSTC40 FL17244.26 ESR-3455 MTS12 FL10456.33 ESR-2613 MSTC52 FL17244.26 ESR-3455 MTS18 FL10456.34 ESR-2613 Weyerhaeuser II-evel Rim Board, LVL, PSL, LSL FL6527.1 - FL6527.4 N/A MTWI 2 FL17244.8 ESR-3455 MTS18 FL10456.35 ESR-2613 D. MATERIAL Cast -Crete Corp. High Strength Concrete Lintels FL158.1 N/A MTW16 FL17244.8 ESR-3455 MTS20 FL10456.36 ESR-2613 Commercial Concrete Products, Inc. High Strength Concrete Lintels FL1774 N/A MTW18 FL17244.8 ESR-3455 MGT FLI 1470.9 SIM200803 Powers Steel, Inc. PSbox8LT, PSbox8LT(5-5/8) FL54,50.1 N/A MTW20 FL17244.8 ESR-3455 MBHA3.56/11.25 FL10866.12 ESR-2616 Powers Steel, Inc. PowerBOX8 Lintels FL1 1383.1 N/A The products listed below did not demonstrate product approval at plan review. I understand that at the time of inspection of these products, the following Information must be MUGT15 FL17240-5 ESR-3447 MBHA3.50/16 FL10866.12 ESR-2616 available to the inspector on the jobsite; 1) copy of the product approval, 2) the performance characteristics which the product was tested and certified to comply with, 3) copy of NFM35XI2 FL578.2 Evaluation Report HDU2-SDS2.5 FL10441.4 ESR-2330 the applicable manufacturers installation requirements. Further, I understand these products may have to be removed If approval cannot be demonstrated during inspection. NFM35X16U FL578.3 Evaluation Report GLTV3.516 FL10667.8 ESR-2615 PAU44 FLI 7239.13 ESR-3449 FGTR FL1 1473.2 SIM200802 PAU66 FL17239.13 ESR-3449 CS16 FL10852.1 ESR-2105 PHD2A FL17219.4 ER-0200 H1 FL10456.5 ESR-2613 PHXU3516 FL17241.20 ESR-3444 H10 FL10456.6 ESR-2613 RFUS FL6223.5 Evaluation Report H10-2 FL10456.7 ESR-2613 E RS150 FL17244.27 ESR-3455 H10A FL10456.6 ESR-2613 RT15 FL17236.11 ESR-3448 H3 FL10456.13 ESR-2613 (D RTI 6-2 FL17236.10 ESR-3448 H4 FL10466.14 ESR-2613 APPLICANT SIGNATURE DATE C_ RT16A FL17236.10 ESR-3448 H5 FL10456.15 ESR-2613 U) RT3A FL17236.11 ESR-3448 H2.5 FL10456A 1 ESR-2613 RT4 FL17236.11 ESR-3448 H2.5A FL10456.12 ESR-2613 RT5 FL17236.11 ESR-3448 H8 I'Ll 1470.3 SIM200803 > RT7 FL17236.11 ESR-3448 Spi FL10456.41 ESR-2613 RT7A FL17236.11 ESR-3448 SP2 FL10456.42 ESR-2613 RTSA FL17236.11 ESR-3448 SP4 FL10456.43 ESR-2613 > SPT22 FL`17244.30 ESR-3455 SP6 FL10456.44 ESR-2613 SPT24 FL17244.31 ESR-3455 SP8 FL10456.45 ESR-2613 0 < SPT4 FL17244.32 ESR-3455 SPH4 FL10456.46 ESR-2 13 4__J SPT6 FL17244.32 ESR-3455 SPHIS FL10456.47 ESR-2613 SPT8 FL17244.32 ESR-3455 SPH8 FL10456.48 ESR-2613 _0 SPTH4 FL17244.32 ESR-3455 U24 FL10655.141 ESR-2549 0 SPTH6 FL172".32 ESR-3455 HHUS28-2 FL10655,3 ESR-2549 SPTH8 FL17244.32 ESR-3455 HHUS410 FL10655.4 ESR-2549 SUH24 FL17232.14 ESR-3445 HGUS5.25/12 FL11468.11 SIM200804 THD28 FL17232.17 ESR-3445 HGUS414 FL11468_.10__ SIM200804 THD28-2 FL17232.17 ESR-3445 HDQ8-SDS3 FL10441.1 ESR-2330 CV THD410 FL17232.17 ESR-3445 MSTAM24 FL11473.19 SIM200802 THD412 FL17232.17 ESR-3445 MSTAM36 FL11473.19 SIM200802 THD612 FL17232.17 ESR-3445 MSTCM40 FL1 1473.19 SIM200802 THDH414 FL17232.18 ESR-3445 HHETA20 FLI 1473.9 SIM200802 UGTS3F FL2033.1 Evaluation Report LGT3-SDS2.5 FL 11470.7 SIM200803 UPHD8 FL17219.6 ER-0200 LGUM26-2 FL 11473.12 SIM200802 - CU LU < Z Z SHEET NO. PA 1.0 C/) > 0 CL 0 Q_ 0 C(3 Florida Department of Business & Professional Regulation Page 1 of 2 Florida Department of Business Professional Regulation Page I of 1 -1--, Building Codes and Standards 1/9/2017 Building Codes and Standards 119/2017 0 ­- Cl) C: = ICU -cu Florida Department of Business 8, Professional Regulation Page I of 2 (1) 10 0 Cl) Product Approval Application Detail Product Approval Application Detail Building Codes and Standards 1/9/2017 = 2 0 FL#15225-R3 FL#15000-R_2 Product Approval Application Detail 0 = -2 c _:g LL Code im Versio Manufacture Entity o Contact Eno Ineer & Licqnse Validated By 209 Date Date Pend Ina Validated Submitted FBC Approval Deft Approved status 2292 I= versio Manufacturer Enthat or Contact Engineer & License Validated By 20 Date Pending Validated Submitted FBCApproval 21a Approved AIW FL*15332-R3 Products .0 CU -1.- 4- Co CU > Revision 2014 Therma-Tru Corporation RickWright National Accreditation & Ryan J. King, P.E 06/28/2015 08/13/2015 07/0512015 Approved Revision 2014 Therrna-Tru Corporation RickWright Lyndon F. Schmidt, RE Ryan J. King, P.E. 06/28/2015 05129/2015 07105/2015 08/19/2015 Approved Quality Assurance Approved for Use Approved for Use Impact Design E 0 Category: Exterior Doors (419) 298-1740 Management I nstkute (813) 767-6555 Category: Exterior Doors (419) 298-1740 PE-43409 (813) 767-6555 Seq X Product Model, Number or Name Product Description Contract Expiration Date In HVHZ Outside HVHZ Resistant Emssure L_ III Subcategory: Swinging Exterior Door Assemblies rickvCrwbldgconsultants. Subcategory: Swinging Exterior Door Assemblies Compliance rickv4rwbidgconsultants. 4 SERIES 420 ALUMINUM SGD REINFORCED SERIES 420 ALUMINUM SGO REINFORCED OX, 12/3112017 No Yes No N/A Cn CU Compliance Method: Certification Mark or Listing com Method: Evaluabon Report from a com XO, )0(96&quot;x98&quot "o CU _4­0 Florida Registered Architect or a Licensed Florida 5 SERIES 420 ALUMINUM SGD REINFORCED SERIES 420 ALUMINUM kD REINFORCED)= 12/31/2017 No yes No NIA U) FL015225-R3 Products Professional Engineer 143&quot:x96&quot; Quality Assurance Approved for Use Aporoved for Use Imoact Design 7 SERIES 420 REINFORCED ALUMINUM SGD SERIES 420 REINFORCED ALUMINUM SGD OXO 12t3l/2017 No Yes No N/A §291 Product Model. Number or Name Product D"crillition Contract Expiration Data In HVHZ Outside HVHZ Resistant Pressure FL#15WD-R2 Products 8 SERIES 430/440 ALUMINUM SGD 146&quot;x96&quot; SERIES 430/440 ALUMINUM SGD X)O( 12/31/2017 No Yes No N/A 5 a. &quot;SmDoth-Star&quot: and &quotBenchmark by 8/8 and 8/0 Opaque and Glazed Fiberglass Door with 12131/2021 No Yes No N/A Quality Assurance Approved for Use Aporoved for Use Impact Design l43&quot;x80&quot; NON -REINFORCED Therma-Tru&quot� and without Sidelites. Inswing and Outswing §221 a Product Model- Number or Name Product Description In HVMZ Outside HV1iZ Resistant Pressure 9 SERIES 430/440 REINFORCED ALUMINUM SGO SERIES 430/440 REINFORCED ALUMINUM SGD 12131/2017 No Yes No N/A 8 f. &quot�Premium Saris-Aquot, &quot;Construction Saris-Acluot; and &quot;Benchmark by Therms-Tru&quot; 8/8 and 8/0 Opaque and Glazed Steel Door with 12131/2021 Transom& With and without Sidelites. Inswing and No Yes No NIA I a. &quot;FIber-CIassic&quot; or &quotSmooth-Slar&quot, 6&#39;8 &quot;Non-Impact8quot; Opaque Fiberglass 12/31/2018 Yes Yes No N/A XXX 143&quotx98&quot with Transoms Outswing Door with &amp; without Sidellts(s) - Outswing (X OX or XO, OXO, X)� OXXO Configurations) Florida Department of Business & Professional Regulation Page I of 1 Building Codes and Standards 119/2017 Product Approval Application Detail Florida Department of Business & Professional Regulation Page I of 2 Florida Department of Business & Professional Regulation Page I of 1 Building Codes and Standards l/W017 FL#15279-R4 Building Codes and Standards 1/1=17 Product Approval Application Detail Qft Entity or 291 2da Date Pending 20 Product Approval Application Detail I= Versio Manufacturer Conact Engineer & License Validated By Validated Submitted FBC Approval Approved Status FLO15217-R4 Revision 2014 Clopay Building Products Company MarkWesterfield fntertek Testrig Services NA, Gary Pfuehler 06/12/2015 03/19/2015 0&21 t201 5 Approved FL#1 I 537-RS QLe Entity or Date Zia Date Pend Ina Category: Exterior Doors (513) 770-W62 Inc. (513) 519-6566 9992 Entity or Dial 20 Date Pend Ina 20 I= Y&Eiiiio Manufacturer 22= Engineer & License Validated By Validated Submitted FBC Approval Approved Status Subcategory: Sectional Exterior Door Assemblies nwvesterfield@clopay.com TVDe Verslo Manufacturer Contact Engineer & License Validated By Validated Submitted FBC Agproval Agproyed Status Revision 2014 MI Windows and Doors Brent Sitlinger Luis Roberto Lomas Steven M. Urich, PE 06/30/2015 06/25/2015 07/06/2015 08/19/2015 Approved Compliance Method: Certification Mark or Listing Revision 2014 CURRIES Division of AADG, Inc Nelson Kraschel UL LLC Ted Berman, PE 07/21/2015 07/21/2015 07/2712015 Approved Category: Windows Subcategory: Single Hung (717) 365-3300 PE-62514 (717) 317-8454 bsi4inger@mMd.com FL#15279-R4 Products Category: Exterior Doors (641) 423-1334 (305) 8684707 Compliance Method: Evaluation Report from a Quality Assurance Approved for Use Approvedl for Use Impact Design Subcategory: Exterior Door Components nelson.kraschel@doorgm Florida Registered Architect or a Licensed Florida S" # Product Model, Number or Name Product Description Contract Expiration Date In KVNZ Outside HVHZ Resistant Pressure Compliance Method: Certification Mark or Listing up.com Professional Engineer 37 037 W5-09 PAN-2Fl 51: 84A, 94, 73, 75, 1500. 190, 76, Steel Pan (min. 25 ga.) Single -Car (up to 9'0"wide) 05/21/2028 No Yes No +30 PSF/-32 FL#1 1537-RS Products FL#15217-R4 Products 78V, 4RST, 4RSF, 6RST, 6RSF, 2RST, 48,42,55,48B, ViA NDCODE8#1 74; W5 Garage Door PSF Assurance 42B. 55S. GD5S, GD5SV, GR5S, GRSSV, ARSS, AR5SV, Sea# Product Model, Number or Name Quality Product Description Contract Expiration Date Approved for Use Approved for Use In KVHZ Outside HVHZ Impact Design Resistant Pressure Product Model. Number or Name Quality Assurance Product Description Contract Expiration Date ADDroved for Use In HVHZ Approved for Use Outside HVHZ Imoact ResiMnt Design Pressure ED5S,ED5SV 1 607. 707, 727, 747, and 847 Single and Pairs of Doors Flush, Glazed, and Louvered single and pairs of 12/31/2017 Yes Yes Yes N/A bed" 4 SERIES GA 195 ALUMINUM SH SERIES GA 195 ALUMINUM SH NI 44X84 12/3112017 No Yes No N/A 53 053W5-16 PAN-21`153: 84A, 94,73,75,1500,190. 4RST, Steel Pan (min. 25 ga.) Double -Car (92" lo 16,0" 05/21/2028 No Yes No +30 PSF/-30 2 M. CM, and G Series Frames hollow metal doom Three sided and four sided single and pairs of l2t3l/2017 Yes Yes Yes N/A 5 7 SER�ES GA 1195 ALUM�NUM SH SERESGA 95ALUMNUMSH SERIES GA 195 ALUMINUM SH NI 54X72 12131/2017 SER:ESGA ALUMINUM SH NI 54X72 12t3l/2017 No No Yes Yes No No N/A N/A 4RSF, 6RST, 6RSF, 48, 42, 55, 488. 42B, 55S, G D5S, wide) WI NDCODE&#1 74; W5 Garage Door PSF frames. Tansornframes. 8 SERIES GA 195 ALUMINUM TRIPLE SH 1195 SERESGA 95 ALUMINUM TRIPLE SH NI 12131/2017 No Yes No N/A GD5SV, GRSS, GR5SV, AR5S, AR5SV, ED5S, ED5SV CONTINUOUS HEAD AND SILL 108X72 NON 85 085 WB-09 PAN-21`1 53: 73, 75, 84A, 94. 42. 48, 42B. 48B, Steel Pan (min. 25 ga.) Single -Car (up In 9'0"wide) 05/21/2028 No Yes No +38 PSF/42 9 SERIES GA 195 ALUMINUM TWIN SH IMPACT SERIES GA 195 ALUMINUM TWIN SH NI 12/31/2017 No Yes No N/A 4RST, BRST, GD5S, GR5S, AR5S, ED5S WI NDCODE&#1 74; W6 Garage Door PSF CONTINUOUS HEAD AND SILL 881/8X72 102 102W6-16 PAN-21"153:73,75,84A, 94,42,48,42B, 488, Steel Pan (min, 25 ga.) Double -Car (97' to 162" 05/21/2028 No Yes No +37 PSF/41 4RST, 6RST, G05S, GR5S, AR5S, ED5S wide) WNDCODE&#174. W6 Garage Door PSF Florida Department of Business & Professional Regulation Page 1 of 3 Florida Department of Business & Professional Regulation Pagel of 1 Building Codes and Standards 1/9/2017 Building Codes and Standards 1/9/2017 Product Approval Application Detail Florida Department of Business & Professional Regulation Page 1 of 1 0 Product Approval Application Detail Building Codes and Standards 1/9/2017 0 FL#1627844 Product Approval Application Detail -4-aid FL#10286-R2 Code Entity o Date Date Date Pend Ina Date CIO 9= Entity or 20 Date Pend Ina Date im Venal Manufacturer Contact Enalneer & License Validated OY Validated Submitted FSC Aporoval Approved Stews FL#15333-R2 I= Verslo Manufacturer Contact Engineer & License Validated By Validated Submitted FSC Approval Approved status Revision 2014 MI Windows and Doors Brent Sillinger Luis Roberto Lomas Steven M. Urich, PE 09101/2015 08/31/2015 09105/2015 10/16/2015 Approved Affirmation 2014 MI Windows and Doors Brent Sitlinger Luis Roberto Lomas Steven M. Urich, PE 04/30/2015 04/30(20115 05110/2015 Approved Category: Windows (717) 385-3300 PE-62514 C717) 317-8454 990 I= Versio Manufacturer Entity a Contact Engineer & License Validated By 2M 20 Validated Submitted DatePendina FSC Approval 20 Approved Category: Windows (717) 385-3300 PE-62514 (717) 317-8454 Subcategory., Fixed Compliance Method: Evaluation Report from a bsidinger@mMd.com Revision 2014 MI Windows and Doors Brent Sitlinger Luis Roberto Lomas Steven M. Urich, PE 0&129t2015 08/19/2015 07/05/2015 08/19/2015 Approved SubCategory: Horizontal Slider tisitlinger(Dmiwd.corn Florida Registered Architect or a Licensed Florida Category: Windows (717) 365-3300 PE-62514 (717) 317-8454 Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Subcategory: Mullions bsit1inger@miwd-conn Professional Engineer FL#15278-R4 Products Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida FLM5208-R2 Products Quality Assurance Approved for Use Approved for Use Impact Design Professional Engineer Dial Product Model. Number or Name Quality Assurance Product Dewriartion Contract Expiration Date Approved for Use Approved for Use in HVHZ Outside HVHZ Im pact Resistant Design Pressure seo # 4 Product Model, Number or Name SERIES GA 195 ALUMINUM PW Product Description SERIES GA 195 ALUMINUM PWNI96X48 FIN 1 In HVHZ Outside HVHZ No Yes Resistant Pressure No N/A FLOOM3-IR2 Products I SERIES GA 198 ALUMINUM HORIZONTAL SLIDER SERIES GA 198 ALUMINUM HORIZONTAL SLIDER 1213112017 No Yes No N/A 5 SERIES GA 195 ALUMINUM PW 12/31/2017 SERIES GA 195 ALUMINUM PWN172X72 2131 1201 7 No Yes No N/A Quality Assurance Approved for Use Approved for Use Impact Design 72X54 FLANGE Product Model, Number or Name Product Description Contract Expiration Date in HVHZ Outside HVKZ Resistant Pressure 2 SERIES GA 198 ALUMINUM HORIZONTAL SLIDER SERIES GA 198 ALUMINUM HORIZONTAL SLIDER 1213112017 No Yes No N/A 7 SERIES GA 195 ALUMINUM PW SERIES GA 195 ALUMINUM PWN196X48 12131/2017 No Yes No N/A 7 1445.5347 AND 5547 VERTICAL MULLION 1445,5347 AND 5547 VERTICAL MULLION 12131/2017 No Yes Yes N/A 3 SERIES GA 198 ALUMINUM XOX HORIZONTAL SLIDER 72X54 SERIES GA 198 ALUMINUM XOX HORIZONTAL 12131/2017 No Yes No N/A 8 FLANGE SERIES GA 275 THERMALLY BROKEN ALUMINUM PW SERIES GA 275 THERMALLY BROKEN ALUMINUM 12t3l/2017 No Yes No N/A SLIDER 108X48 9 SERIES GA 505 ALUMINUM PW PW NI 72X72 FIN SERIES GA 505 ALUMINUM PWN172X72 FIN 12131/2017 No Yes No N/A W 4 SERIES GA 198 ALUMINUM XOX HORIZONTAL SLIDER SERIES GA 198 ALUMINUM XOX HORIZONTAL 12/31/2017 No Yes No N/A SLIDER C_ CD U) 0 ICU CIO C) L_ Florida Department of Business & Professional Regulation Page I of 2 Florida Department of Business & Professional Regulation Page I of I Florida Department of Business Professional Regulation Page 1 of 2 0- Building Codes and Standards 1/9/2017 Building Codes and Standards 119/2017 Building Codes and Standards 1/912017 (D Product Approval Application Detail Product Approval Application Detail Product Approval Application Detail U) ICU FL#13192-R4 FL#15272-R-1 FL#M"-RIO M Code Type Verslo Manufacture Entity a Contact End inger & License Validated By Date Date Date Pend Ina Validated Submitted IFSC Agproval Date Approved Status 2991 Ina Versio Manufacturer Entity o Contact 9011111tLA112=1 Validated By DatePandina Validated IMIMM21 FBC Approval 20 Approved Status 2W I= Varsio Manufacturer Entity or Contact Engineer & License Validated By 21a 292 Validated Submitted Date Pend Ina FSC Aporoyal Approved < Revision 2014 James Hardie Building Products, Inc. Pingsheng Zhu Ronald 1. Ogavva John Southard, P.E, 08126/2015 08/17/2015 09/07/2015 1011W015 Approved Revision 2014 Alside NickThompson Lyndon F. Schmidt, P.E. Ryan J. King, P.E. OZ'2312015 02119/2015 03/01/2015 04/15/2015 Approved Revision 2014 CertainTeed Corporation -Roofing Mark Harrier Robert Nierninen John W. Knezevich, PE 12/14/2016 12/08/2016 1211512016 Pending FBC Approval Category: Panel Walls (Wg) 349-2927 PE-24121 (352) 367-2526 Categorf. Panel Walls (330) 922-2389 PE-43409 (813) 767-6556 Category: Roofing (610) 651-5847 PE-59166 (954) 772-e224 SubCategory: Siding pingsheng.zhu@jameshar Subcategory: Soffits nthompson@alside.00m Subcategory: Asphalt Shingles Compliance Method: Evaluation Report from morkd.hamerosaint-gob Compliance Method: Evaluation Report from a die.00rn Compliance Method: Evaluation Report from a a sin.00m Florida Registered Architect or a Licensed Florida Florida Registered Architect or a Licensed Florida Florida Registered Architect or a Licensed Florida Professional Engineer Professional Engineer Professional Engineer ICU FL#15272-Ri Products FL#13192-R4 Products FL#5W-RIO Products LU Quality Assurance Approved for Use Approved for Use Inloact Design Product Model. Number Name Quality Assurance Product Description Contract Expiration Date Aipproved for Use Approved for Use ln HVHZ Outside HVHZ Imoact Design Resistant Pressure Quality Assurance Approved for for Use Impact §3" Product Model. Number or Name Product Description Contract aullation Date In HVHZ Outside HVHZ Resistant Pressure or Use Avigroyed Design 1 Cemplank Lap Siding fiber-cernent lap siding 01/0112018 Yes Yes N/A N/A a. &quot2T&quot Soffit Vent or Solid Vinyl Soffit 12t3l/2018 No Yes No N/A Product Model, Number or Name Product Descriction Contract Expiration Pjft in HVHZ Outside HVIiZ Resistant Pressure < 2 HardiePlank Lap Siding fiber -cement lap siding 01/01f20118 Yes Yes N/A N/A 2 b. &quotAIhanceT4&quot; Soffit Vent or Solid Vinyl Soffit 12131/2018 No Yes No N/A CertainTeed Asphalt Roofing Shingles 3-tab, 4-tab, strip (no -cut-outs), laminated and 07/03/2017 No Yes N/A NIA Z architectural asphalt rod shingles Z a. SHEET NO. PA 1.1 a-# Product Model. Number or Nam e No. 15 UL Search Criteria Code Version: 2014 Application Type: ALL Category: ALL Application Status: ALL Quality Assurance Entity Contract Expired: ALL Product Description: ALL Approved for use outside HVHZ: ALL Design Pressure: ALL Date To: ALL I'l-82075-1117 2292 y1mig Manufacturer Affirmation 2014 Florida Metal Products Inc. Category: Roofing SubCategory: Roofing Accessories that are an Integral Part at the Roofing System Compliance Method: Evaluation Report from a Product Evaluation Entity FL#2075-R? Products Sea S ct Model, Number or Name 1 RVIO FL#7849-R9 Code TVPe 1�� Manufacture Revision 2014 Boral Roofing Monierl-ifeltile Category: Roofing Subcategory: Roofing Tiles Compliance Method: Evaluation Reportfrom a Product Evaluation Entity FL#7049-R9 Products Sao # Product Model, Number or Name 13 Saxony 700 - Shake, Slate &amp; Split Shake 14 Saxony 900 - Country Slate, Shake &amp, Slate 15 Saxony 900 - Country Slate, Shake, Slate &amp: Split Shake 16 Saxony 900 - Hartford Slate, Split Old English Thatch, Shake, Slate, Country Slate 24 Vi Ila 900 25 Villa 900 28 Villa 900 F1.01128WR5 Code Versio Manufacturer Revision 2014 Town and Country Industries, Category: Shutters SubCategory'. Storm Panels Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer FL#12856-R5 Products AW Product Model, Number or Name 1 0.050&quot, Aluminum Storm Panel 2 &quot;Safety Edge&quot Storm Panels 3 24ga Steel Storm Panel 4 Aluminum Hinged Storm Panel Florida Department of Business & Professional Regulation Page I of 3 Building Codes and Standards I/9=17 Product Approval Application Detail QualityAssurrance Approved for Use Impact Desion Product Description Contract Explafflon Date in HVHZ Outside HVHZ Resistant Pressure Asphalt saturated organic felt 01/0712019 No Yes N/A N/A FIL #: 12328 Product Manufacturer-. ALL Su bcatago ry ALL Compliance Method: ALL Product Model, Numberor Name: ALL Approved for use In HVHZ: ALL Impact Resistant ALL Date From: ALL Florida Department of Business & Professional Regulation Page 1 of I Building Codes and Standards 1/9f2017 Product Approval Application Detail Entity or Date Pend Ina Contact Enaineer & License Validated By Validated Submitted FBC Approval Approved Status Clark Jones Miami -Dade BCCO - EVL Mismi-Dade BCCO - VAL 02127/2015 02t2712015 03/09/2015 Approved (904) 783-8400 (788) 315-2590 clark@flamoo.com QualityAssuraince Aporoved for Use Approved for Use Imoact Desion Product Description Contract Expiration Date In HVHZ Outside HVHZ, Resistant Pressure RV10 ALUMINUM RIDGE VENT 01/31/2018 Yes yes N/A N/A Florida Department of Business & Professional Regulation Building Codes and Standards Product Approval Application Detail Entity or Contact Enalneer & License Validated BY Thomas Jemmett ICC Evaluation Service, LLC Gary W. Walker (602) 269-2288 (205) &8A-0160 thorrvas.jemmettCboral.co m Product Description Flat Profile - Stockton Flay Profile - Henderson Flat Profile - Lake Wales Flat Profile - Stockton Medium Profile - Lake Wales Medium Profile - Denver Medium Profile - Stockton Page I of 3 ltil=17 Date Date Date Pend Ina Date Validated Submitted FBC Apgroval Aigongved Status 09/10/2015 08/25/2015 09/20/2015 Approved Quality Assurance Approved for Use Approved for Use Impa Design Contract Expiration Date In HVHZ Outside HVHZ Resistant Pressure 12/31/2018 No Yes N/A N/A 12/31/2018 No Yes N/A N/A 12131/2018 No Yes N/A N/A 12/31/2018 No Yes N/A N/A 12/31/2018 No Yes N/A N/A 12131/2018 No Yes N/A N/A 12/31/2018 No Yes NIA N/A Florida Department of Business & Professional Regulation Building Codes and Standards Product Approval Application Detail Page 1 of 1 1/9/2017 Entity a _Q& 202 Date Pending Date Contact Engineer & License Validated By Validated Submitted FBC Approval Aporoved ZAWA Tom Johnston Frank 1. Bennardo ORLANDO L. BLANCO, 04/29/2015 04/28/2015 05/04/2015 06/2212015 Approved (954) 493-8551 PE-0046549 P.E. tonriiatc-alum.com (305) 510-8531 Product Description 0.050&quot; Aluminum Storm Panel with Optional Clear Panels &quot;Safety Edge&quot; Storm Panels, 28ga (0.0l8&quot,&quct;) Steel. 0,022&quot; Alum (Pert and Non-Rert), Clear Polycarb (Full and Halo 24ga (0.0232&quot;) Steel Storm Panelwith Optional Clear Panels .050&quot� Aluminum Non -Porous Hinged Storm Panel Quality Assurance Contract Expiration Date Approved for Use ln+IVHZ Approved for Use Outside HVKZ Impact Resistant Desion Pressure 12131/2018 No yes Yes N/A 12131/2018 No Yes Yes +54/-54 12131/2018 No Yes yes +100/-100 12/31/2018 Yes Yes Yes N/A FL#211 675-RO 2292 Type Versio Manufacturer New 2014 HomeGuard Building Products, Inc, Approved Category: Roofing SubCatagory: Underlayments Compliance Method: Evaluation Report from a Product Evaluation Entity FL#21671&0 Products ab" Product Model. Number or Name 1 ToughSkin Synthetic Underlayments FL#17202-R! 2292 TvDe Versla Manufacturer Revision 2014 Lomanco, Inc Category. Roofing SubCategory: Roofing Accessories that are an Integral Part of the Roofing System Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer FL#17202-Ri Products 22" Product Model, Number or Name 1 Deck-Airm DA-4 2 OmniRidge&#174; PRO Vent PR04-N FL#1 5076-113 2292 I= yj2j2 Manufacturer Revision 2014 Global Protection Products, U-C. Category: Shutters SubCatagory: Storm Panels Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer FL#15076-R3 Products Sea 0 1 20 Gage Galvanized Steel Storm Panels/HVHZ 2 24 Gage Galvanized Steel Storm Panels/NHVHZ FL#15076-R4 2292 Tvoe ye= Manufacturer Revision 2014 Global Protection Products, U-C. Category: Shutters SubCartagory Storm Panels Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer FL#15076-R4 Products SG(30 Product Model, Number or Name 1 20 Gage Galvanized Steel Storm Panels/HVHZ 2 24 Gage Galvanized Steel Storm Panels(NHVHZ FL#1780-RO QZLI yq= Manufacturer New 2014 All American Shutters and Glass Category: Shutters SubCategory Storm Panels Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer FL#17869wRO Products seci III Product Model, Number or Name 1 22ga. 24ge Steel Panels Florida Department of Business & Professional Regulation Building Codes and Standards Product Approval Application Detail Pagel of 1 2/6/2017 Entity or Date Contact Engineer & License Validated By Validated Submitted FBC Approval Approved MW John Cheslak I ntertek Testing Services NA, IntertekTesting Services 02101/2017 01/25/2017 02103/2017 (904) 240-1382 Inc. NA, Inc. john.chesiak@hgwrap.co (604) 520-3321 m Quality Assurance Aporoved for Use Acoroved for Use Impact Design Product Description Contract ExaMon Date in HVHZ Outside HV`HZ Resistant Pressure ToughSkin 15, ToughSkin 20, ToughSkin 25, 0110112018 No Yes N/A N/A ToughSkin 30, ToughSldn 50 Florida Department of Business & Professional Regulation Building Codes and Standards Product Approval Application Detail Page I of 1 1/10/2017 Entity or Date 20 Date Pend Ina 292 Contact Engineer & License Validated By Validated Submitted FBC Approval Approved Z= AndrewCarter James L. Buckner, PrE. Steven M. Urich, PE 0510112015 05/01/2015 05/10/2015 06r2212015 Approved (501) 982-6511 PE-31242 (717) 317-8454 acarter@lomenco.com Product Descriction Low Profile, Polypropylene Plastic, Roof Vent Quality Assurance Aporoved for Use Aporoved for Use Contract ExoInstlon Date In HVHZ Outside HVHZ 07110/2019 No Yes Impact Resistant No Design Pressure +97.5/-97,5 Mechanically Attached to Plywood Deck. Molded Plastic, Roof Ridge Vent Mechanically 07/10/2019 No Yes No +N/A/-185 Attached to OSB or Plywood Deck. Florida Department of Business & Professional Regulation Building Codes and Standards Product Approval Application Detail Page 1 of I 119f2017 Entity or Data 20 Date Pending 201 Contact Eno Inser & License Validated By Validated Submitted FBC Aooroval Approved Status Tim Robinson Walter A. Tillit Jr., P.E. John W. Knezevich, PE 05/0612015 04/24/2015 05/11 r2016 06/23/2015 Approved (954) 689-7545 PE-44167 (954) 772-6224 tim,robinron@gppent.com Quality Assurance Approved for Use Apormad for Use Impact Desian Product Descriction Contract JNaMgga2dj In HVHZ Outside HVH Resistant Pressure Corrugated Galvanized Steel Storm Panels retained 12/31/2017 Yes Yes Yes N/A or not by tracks to provide hurricane protection. Corrugated Galvanized Steel Storm Panels retained 12t3l/2017 No Yes Yes N/A or not by tracks to provide hurricane protection. Entity or 20 20 Date Pend Ina 202 contact 1=1111221LAIW= YW31111111111ft yAUg= Submitted FOC Apgroyal Approved Status Tim Robinson Walter A. Tillit Jr., P.E. John W, Knezevich, PE 12121/2016 12t2l/2016 Validated (954) 089-7545 PE-44167 (954) 772-8224 tim.robinson@gppent.com Quality kssurance Approved for Use Approved for Use IMDaCt Design Product Description Contract Explinittlon Date in HVHZ Outside HVHZ Resistant Pressure Corrugated Galvanized Steel Storm Panels retained 12/31/2017 Yes Yes Yes N/A or not by tracks to provide hurricane protection, Corrugated Galvanized Steel Storm Panels retained 12131/2017 No Yes Yes N/A or not by tracks to provide hurricane protection. Florida Department of Business & Professional Regulation Building Codes and Standards Product Approval Application Detail Pagel of 2 1/9/2017 Entity or Date Date Date Pend Ina Date Contact Enalfteer & License Validated By Validated Submitted FBC: Approval Approved saw Mike Barbieri Frank L. Bennardo, P.E Jorge A. Pomerantz, P.E. 07/0312015 07103/2015 07/10/2015 08/18/2015 Approved (561) 712-9882 PE-0046549 (VA) 394-8521 mikeb@allamericanshutte rs.com Quality Assurance Approved for Use Approved for Us Impact Design Product Description Contract Exglratlon Date In HVHZ Ou Resistant Pressure tolds HVHZ 22ga, 24ga Steel Storm Panels 12131/2017 No Yes __7Z_ N/A Florida Department of Business & Professional Regulation Building Codes and Standards Product Approval Application Detail FL#021"3 9292 Entity or Verstio Manufacturer Contact Engineer & License Revision 2014 Thompson Architectural Metals Company, Inc. Scott Brown James L, Buckner Category: Roofing (813) 248-3456 PE-31242 Subcategory: Roofing Accessories that are an flvalidation@yahoo.com Integral Part of the Roofing System Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer FLX5219-R3 Products ANA Product Model. Number or Name Product Description 1 1- &quotFlatTop Off Ridge Ventwith Baffle forTile&quot; Minimum 28 Gauge Steel, Nominal 4&#39;, 6&#39;, 8&#39;, or 10&#39; Wide Off Ridge Vent Attached to Wood Deck 2 2- &quotRound Top Off Ridge Vent with Baffle for Minimum 26 Gauge Steel, Nominal 4&#39;, 8&#39;, Tile&quot; 8&#39;, or 10&#39; Wide Off Ridge Vent Attached to Wood Deck 3 3- &quotStandard Off Ridge Vent with Permanent Baffle Minimum 26 Gauge Steel. Nominal 4&#39. 6&#39;, for Shingles&quot; 8&#39;, or 10&#39: Wide Off Ridge Vent �ttach.d to Wood Deck FL#16588-Ri Code TvDe Versio Manufacture Affirmation 2014 O'Hagin Manufacturing, LLC Category: Roofing Subcategory: Roofing Accessories that are an Integral Part of the Roofing System Compliance Method: Certification Mark or Listing FL#16588-Ri Products Seq 9 Product Model, Number or Name 1 0&#39;Hagin&#39;s Cloaked Vent Tile FLX15090-Ri 220 Versio Manufacture Revision 2014 Global Protection Products, LLC. Category: Shutters Subcategory: Fabric Storm Panel Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Fiords Professional Engineer FILS15088-RI Products Aw Product Model. Number or Name 1 GPP FABRIC SHUTTER -SERIES 2000 FL#1999-R Code UK Versio Manufacture Revision 2014 ITW Building Components Group Inc. Paslode Category; Structural Components SubCatagory: Truss Plates Compliance Method: Evaluation Report from a FL#1999-M Product Evaluation Entity Products i2918 Product Model, Number or Name 1 ITW BCG Higher Strength (H &amp; S) 2 ITW BCG Hinge Plate 3 ITW BCG Trulox 4 ITW BCG Wave Validated By Steven M. Urich, PE (717) 317-8454 page 1 of 1 1,9/2017 20 20 202111= 20 Validated Submitted FBC Approval ADDMved Eau 05/01/2015 04M/2015 05/10/2015 08/2312015 Approved Quality Assurance Avoroved for Use Approved for Use Impact Design Contract Expiration Q= in HVHZ Outside HVHZ Resistant Pressure 12131/2019 No Yes No N/A 12/31/2019 No Yes No N/A 12/31/2019 No Yes No N/A Florida Department of Business & Professional Regulation Building Codes and Standards Product Approval Application Detail Page I of 1 1110f2017 Entity o Date Contact Engineer & License Validated By Validated Submitted FECApprovall Approved Gregory Daniels Miami -Dade 8CCO - CER Ted Berman, PE 06/17/2015 06117/2015 0612512015 Approved (707) 872-3820 (305) 868-4707 gdanielsCohagin.com Quality Assurance Approved for Use Approved for Use Im Pal Design Product Description Contract Expiration Date In HVlZ Outside HV Resistant Pressure Attic Ventilation Product for tile rooting applications 04/04/2018 Yes Yes N/A N/A Florida Department of Business & Professional Regulation Building Codes and Standards Product Approval Application Detail Page 1 or 1 1/9/2017 Entity or 20 20 2WLE2111111M 21111 Contact Engineer & License Validated By Validated Submitted f§QARgOLW Approved Tim Robinson Walter A. Tillit Jr., P.E. John W. Knezevich, PE 04127/2015 04/24/2015 05/03/2015 06123/2015 Approved (954) 689-7545 PE-44167 (954) 772-6224 tim.robinsonQgppent.com Quality Assurance Agigroved for Use Approved for Use Imoact Design Product Description Contract Expiration Date In HVHZ Outside HVHZ Resistant Pressure Coated Polyethylene Fabric Panels retained by tracks 12131/2017 No Yes Yes NIA or direct mounted to provide hurricane Protection. Florida Department of Business & Professional Regulation Building Codes and Standards Product Approval Application Detail Page I at 1 1/9/2017 Entity or 20 Date Date Pending P-4111 Contact Engineer & License Validated YaUg= Submitted FBC Approval Approved Status Stuart Lewis ICC Evaluation Service, LLC William M. Ranieri, PE 03/25/2015 03120/2015 0312912015 Approved (847) 918-6473 (407) 681-1917 sleWs@alpineitw.com Quality Assurance Approved for Use Approved for Use Impact Design Prod uct Description Contract Exigiration Date in HVHZ Outside HVHZ Resistant Pressure Metal Connector Plate 12/31/2020 Yes Yes N A N Metal Connector Plate 12131/2020 Yes Yes NI/A N//AA Metal Connector Plate 12131/2020 Yes Yes N/A N/A Metal Connector Plate 12131/2020 Yes Yes NIA N/A C/) > QQ)) 2 (C:DL 0 2 a 75 ICU ""' C.) -0 0 — U) Cl) =_ a (1) =3 -0 CU 0 —cu -2 C/) -0 0 2 0 co C) C) CIO C) CU > Cn -0 (D Cn E L_ C1113 0 L_ CU '0 U) Z Z W CU > 2 — -6-0 cn CD U) M L�.N M < ICU Z Z < SHEET NO. PA 1.2 I "> FL#2197-R5 999 Versio Manufacturer Revision 2014 MiTek Industries, Inc. Category: Structural Components SubCategory: Truss Plates Compliance Method: Evaluation Report from a FLA2197-RO Product Evaluation Entity Products S-0 Product Model, Number or Nam I M1 8SHS 2 Mll 16 3 MT18HS 4 MT20 5 MT20HS FL#1630-R8 220 TVI)e Verslo Manufacture Revision 2014 Weyerhaeuser Category: Structural Components Subcategory: Engineered Lumber Compliance Method: Evaluation Report from a FLAi630­R8 Product Evaluation Entity Products Product Model. Number or Nam TJI 110 2 TJI 210 3 TJI 230 4 TJI 360 5 TJI 560 6 TJI/560D FIL911774-RAll 220 Versio Manufacture Revision 2014 Commercial Concrete Products,inc. Category: Structural Components Subcategory: Products Introduced as a Result of New Technology Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer FL#1774-R4 Products 229.9 Mouct Model, Number or Name 1 Quality Precast or Commercial Concrete Products Florida Department of Business & Professional Regulation Page I of 1 Building Codes and Standards 1/9/2017 Product Approval Application Detail Entity or 20 20 Date Pandino 2aa Contact Engineer & License Validated By Validated Submitted FBC Approval Approved Status David Wert ICC Evaluation Service, LLC ICC Evaluation Service, 06/30/2015 06/11/2015 0710512015 Approved (314) 851-7480 LLC. dwerb@mji,00m (206) 699-9800 Quality Assurance Approved for Use Approved for Use Impact Design Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure 18 ga. super high strength truss connector plate l2t3l/2017 Yes yes N/A N/A 16 ga. truss connector plate 12/31/2017 Yes Yes N/A N/A 18 ga. high strength truss connector plate l2t3l/2017 Yes Yes N/A N/A 20 ga. truss connector plate 12131/2017 Yes Yes N/A N/A 20 ga. high strength truss connector plate 12/31/2017 Yes Yes NIA N/A Florida Department of Business & Professional Regulation Building Codes and Standards Product Approval Application Detail Page 1 of I 11942017 Entity or 20 20 Date Pend Ina 20 Contact Enalneer & Licen Validated BV Validated Submitted FBC Approval Approved Status JimAnderson ICC Evaluation Service, LLC James A. Rothman, P. E. 07/06/2015 05/12/2015 0713012015 Approved (253) 9244084 (808) 839-1344 jim.anderson2@vmyerhae user,corn 29WUAWZM Approved for Use ADproyed for Use Im part Design Product Descriotion Contract Expiration 2ok n HVHZ Outside HVHZ Resistant Pressure Prefabricated Wood I -joist 03/31/2017 No Yes N/A N/A Prefabricated Wood I -joist OW31/2017 No Yes N/A N/A Prefabricated Wood I -joist 03/3112017 No Yes N/A N/A Prefabricated Wood I -joist 03/31/2017 No Yes N/A N/A Prefabricated Wood I -joist 03131/2017 No yes N/A N/A Prefabricated Wood I -joist 03131/2017 No Yes N/A NIA Florida Department of Business & Professional Regulation Building Codes and Standards Product Approval Application Detail Page 1 of I 1/9/20`17 Entity or Do 20 Date Pending 292 contact Enalneer & License Validated By Validated submitted FBC Aipproyal Approved AWO Robert Gillis THUYH.HUYNH Florida Engineering 07/03t2015 06/24/2015 08/20/2015 OaQW015 Approved (813) 859-3707 PE-60122 Solutions precastgator@yahoo.com (352) 588-5311 Quality Assurance ADDrOved for Use Approved for Use Impact Design Product Description Contract Expiration Date In HVHZ 2A1W_ebYjZ Resistant Prassur Precast and Prestressed Concrete Lintels 05/2512024 No Yes N/A N/A FL#1644-R4 Qu Verslo Manufacturer Revision 2014 Boise Engineered Wood Products Category: Structural Components Subcategory: Engineered Lumber Compliance Method: Evaluation Report from a Product Evaluation Entity FL#1644-R4 Products S"! x Product Model. Number or Name 1 Versa -Lam Search CrIlteria FIL11116527-RO 29silill Veralo Manufacturer Revision 2014 Weyerhaeuser Category: Structural Components Subcategory: Engineered Lumber Compliance Method: Evaluation Report from a Product Evaluation Entity FL#6527-RS Products §W Product Model, Number or Name 1 iLevel Rim Board 2 Microllam LVL 3 Parallam PSL 4 TimberStrand LSL FL#6527-R7 Code I= Verswo Manufacture Revision 2014 Weyerhaeuser Category: Structural Components Subcategory: Engineered Lumber Compliance Method: Evaluation Report from a FLN527-R7 Products Product Evaluation Entity Product Model. Number or Name 1 Microllam LVL 2 Parallarn PSL 3 TimberStrand LSL 4 TJ Rim Board 5 Weyerhaeuser Rim Board 1`05400-115 Qft Versio Manufacture Revision 2014 Powers Steel Inc. Category: Structural Components Subcategory*. Products Introduced as a Result of NewTechnology Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer FL#5450-0 Products §W uct Model. Number or Name 1 PSbox8LT, PSboxSLT(5-5/8) Florida Department of Business & Professional Regulation Building Codes and Standards Product Approval Application Detail Page 1 or 1 1/9/2017 Entity or 20 20 21111LE21H11112. Do Contact Engineer & License Validated 13V Validated Submitted FBCApgroyal Approved Status Robert Taylor [CC Evaluation Service, LLC APA - The Engineered 05/27/2015 05/08/2015 08/02/2015 Approved (541) 828-0200 Wood Association robarttaylorCbc.00m (253) 620-74e7 Quality i$ssurarlce 62piRved for 11.199 Approved for Use Im Pact Desian Product Description Contract EXpiration Date in HVHZ Outside HVHZ Resistant Pressure Laminated Veneer Lumber 01/01/2035 No Yes N/A N/A Florida Department of Business & Professional Regulation Building Codes and Standards Product Approval Application Detail Page 1 of 1 1/912017 Entity or 20 20 Date Pendino contact Engineer & License Validated By Validated Submitted FBC AoDroyal Aggroved Status Jim Anderson ICC Evaluation Service, LLC James A. Rothman, P.E. 07/06/2015 05/1 2t2015 07/30/2015 Approved (253) 924-4064 (808) 839-1344 jimanderson2@weyerhae user.corn Approved for Use ADPro Structural Composite Lumber or Oriented Strand 03131r2017 No Yes N/A N/A board Rim Board Laminated Veneer Lumber 0313112017 No Yes N/A N/A Parallel Strand Lumber 03/3112017 No Yes NIA N/A Laminated Strand Lumber 03f31/2017 No Yes N/A N/A Entity o Dift Pill Date Pend Ina Pj1W Contact Engineer & License Validated By Validated Submitted FBC Approval Apinoved Status Jim Anderson ICC Evaluation Service. LLC James A. Rothman. P.E. 10/31/2016 10/25t2016 11/05/2016 Approved (253) 924-4084 (608) 839-1344 jimanderson2@weyerhae user.corn Quality Assuraaa Approved for Use ApproyU for Use Impact Design Product Descripflon Contract Excirattlon Da in HVHZ Outside HVHZ Resistant Pressure Laminated Veneer Lumber 03/3112017 No Yes N/A N/A Parallel Strand Lumber 03/31/2017 No Yes N/A N/A Laminated Strand Lumber 03t31/2017 No Yes N/A N/A Structural Composite Lumber or Oriented Strand 03/31/2017 No Yes N/A N/A board Rim Board Oriented Strand Board Rim Board 03131/2017 No Yes N/A NIA Florida Department of Business & Professional Regulation Building Codes and Standards Product Approval Application Detail Entity or Contact Engineer & License william powers Steven W. Schaub (802) 437-1160 PE-60509 bill@powerssteel.com Product Description Powers Steel lintels are field assembled lintels consisting of preformed steel lintels combined with concrete masonry units, grout, and steel reinforcing bars, Page 1 of 1 1/9/2017 Pik Date Date Pend Ina Validated By Validated Submitted FBC Approwl Approved 111111tyx SAMUEL A. 03r2&201 5 03rZ3M 15 03130r2015 06/23t2015 Approved GREENBERG, P.E, (813) 645-0166 01/2712017 No Yes N/A N/A FLX1645-R4 Code T­ Versio Manufacturer Revision 2014 Boise Engineered Wood Products Category: Structural Components SubCategory: Engineered Lumber Compliance Method: Evaluation Report from a Product Evaluation Entity FL#1645-R4 Products seq # Product Model. Number or Nam 2 1 AJS Joists FL*158-R7 220 Verslo Manufacturer Revision 2014 CAST-CRETE USA, Inc. Category: Structural Components Subcategory: Products Introduced as a Result of New'rechnology FL*1 58-R7 Products Compliance Method: Certification Mark or Listing S-0 Product Model, Number or Name 1 High Strength Concrete Lintels FL#i 58-RO 2M I= yA= Manufacturer Revision 2014 CAST-CRETE USA, Inc. Category: Structural Components Subcategory: Products Introduced as a Result of NewTechnology FL#1 58-RO Products Compliance Method: Certification Mark or Listing ASAIM Product Model, Number or Name I High Strength Concrete Lintels FL#1 1383-R4 Code IM Versio Manufacturer Revision 2014 Powers Steel Inc. Category: Structural Components Subcategory: Products Introduced as a Result of New'rechnology Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Fiords Professional Engineer ANI Product Model, Number or Name 1 PowerBOX8 Lintels Florida Department of Business & Professional Regulation Building Codes and Standards Product Approval Application Detail Page 1 of 1 119r2017 Entity o 20 Date Date Pend Ina 20 Contact Engineer & License Validated By Validated Submitted FBC Approval Approved Robert Taylor ICC Evaluation Service, LLC APA - The Engineered 05/27/2015 05M/2015 08/0212015 Approved (541) 826-0200 Wood Association roberttaylorabc.com (253) 620-7467 Quality Assurance Approved for Use Approved for Use Impact Design Product Description Contract Expiration Date In H_VHZ outside HVHZ Resistant Pressure Wood &quct;I&quot Joists 01/01/2035 No Yes NIA N/A Florida Department of Business & Professional Regulation Building Codes and Standards Product Approval Application Detail Page 1 of 1 1/9/2017 Entity a 2WA 20 Date Pend Ina 29A contact Engineer & License Validated By Validated Submifted FBOApproval Approved Status Craig Perrino Miami -Dade BCCO - CER Miami-DadeBCCO-VAL 03/1&M15 02124/2015 0311 8t2015 Approved (813) 621-4841 (780) 315-2590 cparrino@casterete.00m Quality Assurance Approved for Use Approved. for Use Im pact D"lan Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Presau 4. 6, 8, and 12 inch wide lintels 05012015 Yes Yes N/A N/A Entity or 20 Date Pend Ina 20 Contm Enalneer & Licens Validated By YAUd= Submitted FBCADoroval Approved 2=1 Craig Perrino Miami -Dade BCCO - CER Miami- Dade BCCO -VAL 05M/2016 04/29/2016 05/06/2016 Approved (813) 621-4641 (786) 315-2590 cparrinoocastcrete.com Quality Assurance Approved for Use Approved for Use Im pact Design rnguct Descrlt)don Contract Expiration QW In HVHZ Outside HVKZ Resistant Pressure 4, 6. 8, and 12 inch wide lintels 05/21r2017 Yes Yes NIA N/A Florida Department of Business & Professional Regulation Building Codes and Standards Product Approval Application Detail Entity or Contact Engineer & License william powers Steven Schaub (602) 437-1160 PE-80509 billQpowerssteel oom Product Description Powers Steel Lintals are field assembled consisting of preformed steel lintels combined with brick or concrete masonry units, grout, and steel reinforcing bars. Page i of 1 I/W017 pig 20 Date Pending Date Validated By Validated Submitted FBC Aporoyal Approved SAMUEL A. 03/2612015 03123/2015 0$W12015 08/2212015 Approved GREENBERG, P.E. (813) 645-0166 Quality Assurance Approyed for Use Approved for Use impact Design Contract Expiration Date In HVHZ Outside HVHZ Resistant Pressure 01/0112017 No Yes N/A N/A Cn -a > 4­0 Ld) 2 ca- C:)- 0 0 C5 0 -0 Cn -L-- 0 CU -cu in CU 0 L1_ �.*_ 0 CU > (n -0 a) Cn E L_ CU "0 ca. CU -0 1002 . a -6-0 (n CD- < z z W mi CIO C: 0 0 CIO (1) _9_— U) 0 0 L CL 0_ 0 =3 -00 M CD LU < (3) Z z a - SHEET NO. PA 1 n3