Loading...
HomeMy WebLinkAbout36101 Stable Wilk Ave0 INDEX OF DRAWINGS SHEET DESCRIPTION SHEET No. CS COVER SHEET 1 MAIN FLOOR PLAN 1.1 UPPER FLOOR PLAN 2 INTERIOR ELEVATIONS 3.1 EXTERIOR ELEVATIONS 3.2 EXTERIOR ELEVATIONS F1 FOAM DETAIL 4 MAIN ELECTRICAL PLAN 4.1 UPPER ELECTRICAL PLAN 5 ROOF PLAN 6 FOUNDATION PLAN 7 MAIN FRAMING PLAN 7.1 ROOF FRAMING PLAN �7 8 LINTEL DETAILS SN STRUCTURAL NOTES SN1 DETAILS S3 STEM DETAILS S4 DETAILS S5 DETAILS S6 DETAILS ST STAIR DETAILS ABBREVIATIONS SS RETROFIT DETAILS D1 SECTIONS & DETAILS A.B. Anchor Bolt F.P. Fireplace P.T. Pressure Treated Abv. Above F.O.M. Face Of Masonry Pwd. Powder Room L WP WATERPROOFING DETAILS A/C Air -Conditioner Ft. Footif Feet Rad. Radius ADJ. Adjustable Ftg� Footing Ref. Refrigerator PA1.0 RODUCT APPROVAL NUMBERS A.F.F. Above Finished Floor A.H.U. Air Handler Unit FIX Fixed Req'd. Required PA1.1 PRODUCT APPROVAL NUMBERS ALT. Alternate GaIv. Galvanized Rm. Room PA1.2 PRODUCTAPPROVALNUMBERS B.A. Base Cabinet G.C. General Contractor Rnd. Round BF Bifold Door G.F.I. Ground Fault Interrupter RIS Rod and Shelf PA1.3 PRODUCTAPPROVALNUMBERS Bk Sh BookShelf G.T. Girder Truss SD. Smoke Detector Bm. Beam Hdr. Header S.F. Square Ft. r r Bot. Bottom Hgt. Height Sh. Shelves B.P. Bypass door HB Hose Bibb SHT Sheet BRG. Bearing Cir. Circle Int. Interior S.L. Side Lights C D lZ a D; C; Cig. Ceiling KNall Kneewall Flu�v "V I Ci Control Joint K.S. Knee Space Sq, Square Col. Column Laun. Laundry S.Y.P. Southern Yellow Pine Comm. Community Lay. Lavatory TB Towel Bar Comp. Compressor L.F. Linear Ft. Temp. Tempered E C.T. CeramicTile LL Lintel Length Thik'n. Thicken D. Dryer LT. Laundry Tub T.O.B. Top of Block DB Door Bell Mas. Masonry T.O.M. Top of Masonry Dec. Decorative T.O.P. Top of Plate Ded. Dedicated Outlet Max Maximum Dbl. Double M.C. Medicine Cabinet TR TOWEL RING Dia. Diameter Mfgr. Manufacturer TP TOILET PAPER Disp. Disposal Micro. Microwave Trans. Transom Window Dist. Distance Min Minimum Typ- Typical D.S. Drawer Stack M.L. Microlam UX. Under Counter D.V. Dryer Vent Mir. Mirror UCL Under Cabinet Lighting D.W. Dishwasher Mono Monolithic U.N.O. Unless Noted Otherwise Ea. Each N.T.S. Not to Scale V. Shower Valves E.W. Each Way VB Vanity Base Elec. Electrical Opn'g. Opening Vert. Vertical Elev. Elevation Opt� Optional V.L. Versalam Ext. Exterior PC. Piece VTR Vent through Roof Exp. Expansion Ped. Pedestal w Washer FBC Florida Building Code PH PHONE W/ With Fin. Fir. Finished Floor P.L. Parallam W/C Water Closet F.G. ixed Glass PLF Pounds per linear foot W.A. Wedge Anchor Fir. Floor Pit. HI. Plate Height Wd Wood Fdn. Foundation Pit Sh. Plant Shelf WP Water Proof Fir Sys Floor System PSF Pounds per square foot REVISIONS 08-20-15 1.00 NEW BASE PLAN OP Y, Zk 12-08-15 2.0 FRAME-WAL REVISIONS kl '-4, �-C �10 C, 4,/;P, % C6 'Nji, D& Q)J�l -IAI MEAN ROOF 15 FT. HIGH TYPICAL FOR SINGLE STORY HOMES MEAN ROOF 30 FT. HIGH TYPICAL FOR 2 STORY HOMES THIS DRAWING AND DESIGN IS VALID FOR 12 MONTHS AFTER THE DATE IT IS SIGNED AND SEALED OR WHILE CURRENT CODE IS VALID Notice to Builder & All Subcontractors It is the intent of Designer/Engineer listed in the titleblock of these documents that these documents be accurate, providing Licensed Professionals clear information. Every attempt has been made to prevent error. The Builder and all subcontractors are required to review all the information contained in these documents, prior to the commencement of any work. The Designer/Engineer are not responsible for any plan errors, omissions,or misinterpretations undetected and not reported to the Designer / Engineer prior to construction. All construction MUST be in accordance to the information found in these documents. Any questions regarding the information found in these plans should be directed to our Office at (407) 880-2333 immediately. No backcharges will be considered for reimbursement by the Designer/Engineer without 2575 advanced notification and approval by the Designer/Engineer. Payments will be made in accordance to the terms of the agreement. co Z a_ Q) 4--J Lu U 0 V) -E 0 W in cy) 0 Co C W cl) E 0 L) 2 -0 M = cli 0 0 Rig :C Qj ( J Q., C, :E u- co 05 W iiiiiiiiiiiiiii,im a) -0e (0 0-0 < A I RD. r W D W �t Z:� V� St, ft.. 0 , - Z W I—A"d - ' '�!� E ;0� L—. Ne, 13 0,9- -0 1 C, U OJ, W Z, I 0 Z r 9 C, ca 0 tg':29 E 0, CJ —J t3 To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code 5th Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. C) 0 Z 0 F-4 > Lo ce) p f 0 Ln Z V) cu Ln L- u- fo CL 00, Z < Z E Z C:) WUJ J C:) 0Z 2 WE � g Z 08 Z a ,UZ--. ,=)Zz 0 Z, LU Lu 00 Z Lu LU 8 in Z Z r �E Lr) C/) U.1 Z 0 -0 N Lr) U-1 -F' :> 0 0 U Z 0 IA F- g X '0 �UJ 2 m 0 -0 Z 2� LU Ce Z 0 < r'Q . F� Z Z UJI --1 Lr) < Z 90ZO ro < Z W Z CY Z 0 0 N <r, LU < V) Z W rn 0— Ln SCALE AS NOTED DATE 2/24/2014 TECH: MJAMES VERSION NO 2.0 SHEET NO. CS 111111 *11111 cli 5-SH 16" DE P r— — — — — — 24 24 PIT OPT. CNIA F IF _-PA SITFV E REF. 26611 B.F r 2x6 WALL 12'4' 2968 BID KITCHEN <Hl' 8'-81"F0T ql_G.� Tlo_�_ 0 04 EDGE OF SLAB 2" 0 BEYOND WALL rcc 3. 36 36 .3 S3) I ci — — — — — — — — — — - UJ > Ic CID I _j Lj L —0-- r- .0 DO CN C14 X 41-01, 6-1 6-6" 20'-8" 4-4* 2 CAR GARAGE DINING ROOM 8'-8" FLAT CLG. PATIO 8'-8" FLAT CLG. CARPET BUILDER TO PROVIDE (D 9 00 2'-6" 1, APPLIANCE PROTECTION CWD WHEN REQUIRED PER FBC X 2041 (3 2X4 # L — — — — — — — — — — JJI 3)16 OEWA D 4-4- x-0-L S3 C� (3) 2X4 #2 SPF W/ �(3 S BAS W.H. W --A (3) 16d TOENAILS @ 9 BASE \—(2) #5'S TYP 2 STORY OYER--\, 1 @ 1 3068 0 01 0 0 0 0 8'-8" FLAT CLG. X j _j _j LO u_ u- u_ TILE C 9 9 16-4�' T-13" T-8" --13" 3 6-0" 4'-2" 10 111 TR)� L9 2068 B.F., HDR AT T-4" 8'-8" FLAT CL 9 I= mlimliiN 2" DEE 5-SH 9yr WAI I 4'-0" [il- 011 (2) #5'S z C, 4 -1 Ln 100 1 4) P R L (3) 2X4 #2 SPF 8'-8'FL G. FLEX FAMILY ROOM M (3)16d M 8'-8" FLAT CLG. T TOENAILS@ R 12 I CARPET 8'-8" FLAT CLG. BASE . Cn Go CARPET *42"SLOPING 11 ;0 C1,11 HALF WALL 10 LL FLOOR G.T. 9 00 3 4 15 1 17 18 rCO N D� I I I I I I JU UP!16R! . I Ar G in (S3V I �1 I TYP @ 2 STORY �6 lr__ I 'I HEADER SCHEDULE MARK HEADER SIZE REMARKS (2) - 2X6 #2 SYP W/ 1/2" FLITCH PLATE (2) - 2X8 #2 SYP W/ 1/2' FLITCH PLATE (2) - 2X1 0 #2 SYP W/ 1/2" FLITCH PLATE (2) - 2X12 #2 SYP W/ 1/2" FLITCH PLATE (2) - 13/4" X 11 1/4 LVL 2.OE Fb=2950 (2) - 13/4" X 9 1/4" LVL 2.OE Fb=2950 (2) - 13/4" X 16" LVL 2.OE Fb=2950 (2) - 13/4" X 7 1/4" LVL 2.OE Fb=2950 (2) - 2X4 #2 SYP W/ 1/2" Follow Q/S4. See Plan for R.A.G. FLITCH PLATE Bearing Wall Call Out When Straps are Required VERIFY W1 PLAN CORRECT LENGTH OF HEADER REQUIRED SEE PLAN FOR DETAIL CALL OUT FOR CONNECTIONS AND REQUIRED STUDS WINDOW SCHEDULE SIZE R.O. CMU (Flange) R.O. FRAME (Fin) TYPE 12 20 X 26 18JX25j S.H. 13 20 X 381 18JX371 S.H. 14 20 X 50 1 18 j X 50 S.H. 15 20 X 63 18 j X 62 j S.H. 16 20 X 72 18JX71 j S.H. j 32 27 114 X 26 26 X 25 j S.H. J33 27 1/4 X 38 j N/A S.H. j 34 271X501 NIA &H. J33 N/A 26 x 37 1 S.H. j 34 N/A 26 x 50 S.H. J35 271X63 26 X 62 1/2 S.H. J36 271X72 26 X 71 1/2 S.H. 22 37JX26 36 j X 25 1/2 S,H. 23 37JX381 36 1 X 37 3/4 S.H. 24 37JX501 36 j X 50 S.H. 25 37JX63 36 j X 62 1/2 S.H. 26 37JX72 36 j X 71 112 S.H. DOUBLE 2 WIDE 75" TALL 73 j WIDE S.H. 32 54 X 26 52JX25i S.H. 33 54 X 381 52 JX 37 j S.H. 34 54 X 501 52 JX 50 S.H. 35 54 X 63 52JX62i S.H. 36 54 X 72 52JX71 j S.H. 39X59 40 X 59 N/A S.H. DOUBLE 39X59 79 X 59 N/A S.H. General notes R302.5 Dwelling/Garage Opening/Penetration Protection. • Openings from a private garage directly into a room used for sleeping purposes shall not be permitted. Door between garage and residence shall be equipped with solid doors not less than 1 3/8" In thickness, solid or honeycomb -core steel doors not less than 1 3/8" thick, or 20-minute fire -rated doors, equipped with self -closing device. • Duct Penetration. Ducts in the garage and ducts penetrating the walls or ceilings separating the dwelling from the garage shall be constructed of a minimum No. 26 gage (0.48 mm) sheet steel, 1 inch minimum rigid nonmetallic class 0 or classl duct board, or other approved material and shall have no openings into the garage. • Other penetrations shall be protected as required by section R302.1 1, Item 4. R302.6 Dwelling/Garage Fire Separation. The garage shall be separated from the dwelling as per the following: • From the Residence & Attics - Not Less than 1/2" Gyp. Bd. or equivalent applied to garage side. • From Habitable Rooms Above Garage - Not Less than 5/8" Type-X Gyp. Bd. or equivalent. • Structure(s) Supporting Floor/Ceiling Assemblies - Not Less than 1/2" Gyp. Bd. or equivalent. • Garages Located Less Than 3 Feet From Dwelling On The Same Lot - Not Less than 1/2" Gyp. Bd. or equivalent applied to the interior side of exterior walls that are within this area, R312.2.1 Window Sills. In dwelling units, where the opening of an operable window is located more than 72 inches above the finished grade or surface below, the lowest part of the clear opening of the window shall be a minimum of 24 inches above the finished floor of the room in which the window is located.Operable sections of windows shall not permit openings that allow a 4-inch-diameter sphere where such openings are located within 24 inches of the finished floor. Chapter 45 Private Swiming Pools, Section R4501.17.1.9 All doors and windows providing direct access from the home to the pool shall be equipped with an exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 db a at 10 feet. Any deactivation switch shall be located at least 54 inches a ove t e t res o o t e acces . eparate a arms are not required for each door or window if sensors wired to a central alarm sound when contact is broken at any opening. M 1507.2 Recirculation of Air. Exhaust air form Bathrooms and toilet rooms shall not be recirculated within a residence or to another dwelling unit and shall be exhausted directly to the outdoors. Exhaust air from bathrooms and toilet rooms shall not discharge into an attic, crawl space or other areas inside the building. GAS APPLIANCES G.C. to verify location of gas riser before commencement of work. see Sht. SN1 for installation detail. Where gas water heaters are installed. Water heaters shall be installed a min. of 18" above fir. per FBCR G2408.2. Except where appliances that are listed as flammable vapor ignition resistant. OPENING PRESSURES ENCLOSED - EXPOSURE "C" +25.6 -27.8 +25.6 / -34.3 +24.5 -26.7 +24.5 / -31.9 +23.0 -25.2 +23.0 / -28.9 SEE SN SEE SN SHEET rH SHEET 140 MPH NOTE: WIND SPEED INDICATED ABOVE IS AN "ULTIMATE" WIND SPEED. THE WIND PRESSURES LISTED ABOVE ARE ALLOWABLE PRESSURES WALLLEGEND TYP. 2x FRAME WALL BEARING WALL INTERIOR BEARING WALLS NOTED "FLOOR BEARING ONLY'ARE FLOOR SYSTEM SUPPORTING ONLY AND REQUIRES NO UPLIFT CONNECTORS TO FLOOR SYSTEM AREA TABULATION 111311 1ST FLOOR LIVING AREA 1093 2ND FLOOR LIVING AREA 1489 LIVING TOTAL 2582 GARAGE 427 FRONT ENTRY 35 TOTALAREA 3044 INSULATION REQ. LOCATION R-VALIJE / TYPE EXT CONIC WALL ME MotIH PERM EXT FRAME 2 x 4 R-1 1 /R- 13 KRAFT FA��_ED EXT FRAME 2 x 6 R-19 KRAFT FACED CONDITIONED CEILING R-30 BLOWN -IN (INSTALL BAFFELS AT EAVE) (Dva Z�; CL 0 C_r) U_j U U, 0 E Ul) 0 V) 00 co I-- c\l W Cl) C M Cl) C: C14 E T-0c) 0 0 q 00 a) = LL 00 a) 15 � 00 1A 0 M (D 0) C/5 'C' lc-" -,z Lo 0 -t .,f --: < 0 0 N B 8D !d 9 co e:4-e %; _j Z, 409 IN CL IrD, rc: -C-L 0 &1 0 00 *8' mo M 63 zc� oA.. (A'a 0 '-,v Co. < UM To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained withi n these drawings comply with the Florida Building Code Sth Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. I C) Z 0 11-� 4-J C:) (1) 15 �.o > o p U-) M Ln < z M V) 0 N (1) — Ln C, - e-s U ro U 00 z z 3i E fu W LU C:) _j C) 11.0 0, Ln z z a: C� r Z80 o- 0 Lo� of �_Uz< ,=)Zz z .2 C14 1Qz@ CL 8 W) z z 0 U 2: z Ln 0 z 0 :5 0 - L4 fu Lr) LjL > z 0 C/) < U Lu 01 �� R OZ < r U, , cc' < �Z< Lu �� w<J < 3: ti z r-4 0 M z (1114 C, LU Lr) 6i L, oz, OZ8 LIJ 2 w < z Lu z < W CY-) z =) < 01 j) T--4 z Z M LLI 0 0 z Lu rn T__I U0 SCALE AS NOTED DATE 2/24/2014 TECH: MJAMES VERSION NO - 10 SHEET NO. 1.0 GARAGE SEPARATION I R-1 1/R-13 KRAFT FACED (GARAGE / LIVING) Z� T` Cl U. 39'-0" 111%1 All 10-0 e_v --t a 01 ep @ ri_,� DRNERS D2 N.O. 25 -SH�� R&S EGRESS - - - - - - - Cczz FIBERGLAS SURROUN TYP @ 2 STORY W.I.C. BEDROOM I 4 P - (D 3 18'-0" FLAT CLG. 1 D2 8'-0" FLAT CLG. CARPET 3) BEDROOM 3 8'-0" FLAT CLG. OH1 2 (01 , Cal M I Ca X � V lil -1 6-r-0 04 Oct) CARPET w1w 9 7'-1P2 ROOF G.T. 1T-0" .11 - - a W 64 6-52-'" 2'-4" 4'-22" 0 00 C*4 0 LL 0 TYP @ 2 STCRY 00 00 W 4068 B.F. C14 V-10" �6 (D C*4 9 W z u.: MW LU 4068 B.F. __'�SIIVI 60"X36" (Do z C6 2'-3" SHOWER - - - - - - - - 6. :3 00 - - (D co C4 K3 FIBERGLA,'$----- R&S - 0 OP 04 2668 - - - - - - - - - - - - - �, �2 w/ (5) STUDS SURROUN) 0 W. 4'-0" ;0 -1 6�10" - 6'-101'\\ //j (J 64" 2 -41" 2668 13'-721" Cl) 0 co 4- W BEDROOM 2 IN W 8'-0" FLAT CLG. ? 8'0" BKT_E FLA� CLG G I I 2.q r,.q 35ux.2_2" ATTIC CARPET T 10 L F Eng J P .61 1:6 00 10 T_ TI _E Ob 00 =W W LO -7- T- 3*1 2'4" V-1 0!768 64" 2'-6". 00 Ln 9 16'-8" U") T-71- OWNER'S �G 16 A. 6 SUITE LOFT 4) 8'0" FIAT CLG. 14 in W OP (r Ln CARPET 13 --- 1 V-0" FLAT CLG. CARPET H03 Cl) 0 - T ROOF G.T. td z L6 04 TYP @ 2 STORY 1 12 41 51 61 ]8 I S2 TYP @ 2 STORY 7 zo S6 EN LL. *- _j I _I 38'-0" )'-0'. HEADER SCHEDULE MARK HEADER SIZE REMARKS (2) - 2X6 #2 SYP W/ 1/2" FLITCH PLATE (2) - 2X8 #2 SYP W/ 1/2" FLITCH PLATE <@>(2) - 2X1 0 #2 SYP W/ 1/2" FLITCH PLATE (2) - 2X12 #2 SYP W1 1/2" FLITCH PLATE <e>(2) - 13/4" X 11 1/4 LVIL 2.OE Fb=2950 (2) - 13/4" X 9 1/4" LVIL 2.OE Fb=2950 (2) - 13/4' X 16" LVI_ 2.OE Fb=2950 (2) - 13/4" X 7 1/4" LVL 2.OE Fb=2950 (2) - 2X4 #2 SYP W/ 1/2'. Follow Q/S4. See Plan for R.A.G. FLITCH PLATE Bearing Wall Call Out When Straps are Required VERIFY W1 PLAN CORRECT LENGTH OF HEADER REQUIRED SEE PLAN FOR DETAIL CALL OUT FOR CONNECTIONS AND REQUIRED STUDS 140C EXTERIOR 2ND FLOOR BEARING WALL SCHEDULE HEIGHT STUD SPECIES SPACING SPF #2 81-011 2x4 Syp #2 16" O.C. SPF #2 91-011 2x4 SYP #2 16" O.C. SPF #2 >91-011 2x6 Syp #2 16" O.C. * IF WITHIN 4FT OF END ZONE, USE DOUBLE STUDS AT CORNERS ** WALL SHEATHING 15/32" EXPOSURE I OR EQUIVALENT SEE C/S6 WALL SCHEDULE WINDOW SCHEDULE SIZE R.O. CMU (Flange) R.O. FRAME (Fin) TYPE 12 20X26 18 JX 25 j S.H. 13 20 X 38J 18JX 37 j S.H. 14 501 18JX 50 S.H. 15 20X63 18JX62j S.H. 16 20 X 72 18 j X 71 j S.H. J32 27 1/4 X 26 26X25J S.H. J33 27 1/4 X 38 N/A S.H. 3134 27 j X 50 1 N/A S.H. J33 N/A 26 x 37 S.H. J34 N/A 26 x 50 S.H. J35 27JX63 26 X 62 1/2 S.H. J36 27 j X 72 26 X 71 1/2 S.H. 22 37JX26 36 j X 25 1/2 S.H. 23 37JX38j 36 j X 37 314 S.H. 24 37 j X 50 j 36JX50 S.H. 25 37 j X 63 36 j X 62 1/2 S.H. 26 371X72 36 j X 711/2 S.H. DOUBLE 2 WIDE 75"TALL 73JWIDE S.H. 32 54 X 26 52JX25j S.H. 33 54 X 381 52JX 37 j S.H. 34 54 X 501 52JX 50 S.H. 35 54 X 63 52 j X 62 1 S.H. 36 54 X 72 52 j X 71 j S.H. 39X59 40 X 59 N/A S.H. DOUBLE 39X59 79 X 59 N/A S.H. General notes R302.5 Dwelling/Garage Opening/Penetration Protection. • Openings from a private garage directly into a room used for sleeping purposes shall not be permitted. Door between garage and residence shall be equipped with solid doors not less than 13/8" in thickness, solid or honeycomb -core steel doors not less than 1 3/8" thick, or 20-minute fire -rated doors, equipped with self -closing device. • Duct Penetration. Ducts in the garage and ducts penetrating the walls or ceilings separating the dwelling from the garage shall be constructed of a minimum No. 26 gage (0.48 mm) sheet steel, 1 inch minimum rigid nonmetallic class 0 or classl duct board, or other approved material and shall have no openings into the garage. • Other penetrations shall be protected as required by section R302.1 1, Item 4. R302.6 Dwelling/Garage Fire Separation. The garage shall be separated from the dwelling as per the following: • From the Residence & Atfics - Not Less than 1/2" Gyp. Bd. or equivalent applied to garage side. • From Habitable Rooms Above Garage - Not Less than 5/8" Type-X Gyp. Bd. or equivalent. • Structure(s) Supporting Floor/Ceiling Assemblies - Not Less than 1/2" Gyp. Bd. or equivalent. • Garages Located Less Than 3 Feet From Dwelling On The Same Lot - Not Less than 1/2" Gyp. Bd. or equivalent applied to the interior side of exterior walls that are within this area. R312.2.1 Window Sills. In dwelling units, where the opening of an operable window is located more than 72 inches above the finished grade or surface below, the lowest part of the clear opening of the window shall be a minimum of 24 inches above the finished floor of the room in which the window is located.Operable sections of windows shall not permit openings that allow a 4-inch-diameter sphere where such openings are located within 24 inches of the finished floor. Chapter 45 Private Swiming Pools, Section R4501.17.1.9 AJI doors and windows providing direct access from the home to the pool shall be equipped with an exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 db a at 10 feet. Any deactivation switch shall be located at least 54 inches above the threshold of the access. Separate alarms are not required for each door or window if sensors wired to a central alarm sound when contact is broken at any opening. M 1507.2 Recirculation of Air. Exhaust air form Bathrooms and toilet rooms shall not be recirculated within a residence or to another dwelling unit and shall be exhausted directly to the outdoors. Exhaust air from bathrooms and toilet rooms shall not discharge into an attic, crawl space or other areas inside the building. GAS APPLIANCES G.C. to verify location of gas riser before commencement of work. see Sht. SN1 for installation detail. Where gas water heaters are installed. Water heaters shall be . stalled a min. of 18" above flr. per FBCR G2408.2. Except where app ances a are s as amma e vapor gni ion sis n . OPENING PRESSURES ENCLOSED - EXPOSURE "C" +25.6 -27.8 +25.6 / -34.3 +24.5 -26.7 +24.5 / -31.9 +23.0 -25.2 +23.0 / -28.9 SEE SN SHEET SEE SN SHEET MPH NOTE: WIND SPEED INDICATED ABOVE IS AN "ULTIMATE" WIND SPEED. THE WIND PRESSURES LISTED ABOVE ARE ALLOWABLE PRESSURES WALL LEGEND TYP. 2x FRAME WALL BEARINGWALL INTERIOR BEARING WALLS NOTED"FLOOR BEARING ONLY" ARE FLOOR SYSTEM SUPPORTING ONLY AND REQUIRES NO UPLIFT CONNECTORS TO FLOOR SYSTEM AREA TABULATION 111311 1 ST FLOOR LIVING AREA 1093 2ND FLOOR LIVING AREA 1489 LIVING TOTAL 2582 GARAGE 427 FRONT ENTRY 35 TOTALAREA 3044 INSULATION REQ. LOCATION R-VALUE / TYPE EXT CONC WALL R-4.1 HIGH PERM EXT FRAME 2 x 4 R-1 1 /R- 13 KRAFT FACED EXT FRAME 2 x 6 R-19 KRAFT FACED CONDITIONED CEILING R-30 BLOWN -IN (INSTALL BAFFELS AT EAVE) GARAGE SEPARATION jR-11/R-13 KRAFTFACED (GARAGE / LIVINi (D LOG Z �; 0 Z cola z CL co C-n Uj U 0 LU V) V(0 0 C) 0`1 a) cl) i-- E 0 L) 0) ce) C ca 0 2 70 M 0 = C"! 2 -17 Qj Wig a) 0 LL 00 00 0 < C). 0, 0) < 6 N C B-D-C *�'Co z C'.) Am 00 �j _j W 4W C5 AL '10 CIL ft_rLL_ mo. Lu LL LLI 0 0. Z < 9, 11-4 Z t 1�" Z g.. a 8 LL 8� <A, -, 04 01 4 3w, 0 1.04 To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code Sth Edition (2014) Residential. Engineer's signature and sea] is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seaL C�' Z 0 P­1 4-J Ln > o p (V Lr) z a) -0 LA CL LL F_d � fy) 170 -j 0� U 0_ 00 z < z E z LU C:) W 0 z 0 Ul z z '0 r z 0- � 0 z LU cr Uz< z Z Lu Z 12 z - LH 2r 0. 0� 0 L. M z 8 VW) Z Z >< 8 Lr) 0 z 0 -0 N 0 _j D fu Lr) LL > 0 z < U U-) C\j Uj P, 0, z se U C'4 0 ;i: < z t2 d z< < < Fm 0 z LU r*4 Lr) 0 L" 3 �j Z, T__1 - - LU L 2: 2 8 z 0 8 2 < 110 0) < < Lu z CY) z z Cy Ln Z 0 LLI 2 < U) z Lu Ul) z c' SCALE AS NOTED DATE 2/24/2014 TECH: MJAMES VERSION No' 10 SHEET NO. STANDARD (3) 2x12 STRINGERS w/ SIMPSON A35/USP MP34 CLIP TO FLOOR SYSTEM OR LANDING FRAMING (2) 2x HDR. REQ'D @ END OF LANDING FOR STRINGERS TO CONNECT TO PLY SHEATHING OVER LANDING ATTACHED PER GENERALFLOOR CONSTRUCTION NOTES 2x8 #2 SYP JOISTS @ LANDING @ 16"O.C. W/ SIMPSON A35/USP MP34 OR LUS26 HANGER ON EA. SIDE MASONRY OR WOOD WALL, SEE PLAN W 0 2x8 #2 SYP (P.T. IF MANSONRY Z WALL) CONT LEDGER w/ (3) 16d NAILS @ 16" O.C. MAX. TO EA. STUD. ((2) 1/4"X3 1/2" TITENS @ 16" O.C. MAX. FOR MASONRY WALL) MIRROR 0 11LILE 1. I I I I L___ LI OWNER'S BATH KITCHEN ISLAND SCALE: N.T.S. 9'-0" MAX LANDING LENGTH 2X8 #2 SYP JOISTS @ LANDING @ 16" O.C. wl SIMPSON A35 CLIP OR LUS26 HANGER TO LEDGER 2x12 HDR. w/ (3) 2x STUDS AT EA. END FOR BEARING STANDARD (3) 2X12 STRINGERS W/ SIMPSON A35 CLIP TO HDR. 1x TREADS (TYP.)--\-, CONT. HANDRAIL GENERAL LANDING FRAMING INFO. 9 L= KITCHEN THRUST BLOCK SECURED TO SLAB w/ 1/4"X3 1/2" TAPCONS @ 16" O.C. PLYWOOD @ LANDING BATH 2 2x8 LEDGER #2 SYP w/ (3) 16d NAILS TO STUD @ 16" O.C. U') I SEE PLAN FOR LANDING DEPTH i 60 Aq a PRE-ENG FLOOR JOIST W/ (2) 0 0 0 Z Z cog Z U) Z Q) C_A) LU 0 LU 0 V) 04 C) (D cl) 0) co LU a W cl) E Ct$ 'a Cl) = C14 8 6,0. Qj :S u- co c). 5,6!� 0 1,D 0) -r, -, U.) 0 q. a 0. ---:, < CM < 0 A c a D. Lo R, cc *L0 X Z 0 __J *SkA Lu C9.0 L 111 r C, 4 F F E To the best of the Engin4Pf, M nd belief, the structural plans an hrlc� within these drawings comply with the Florida Building Code 5th Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. c) C�' Z 0 #-a C) un C) V) fU LO tn Z Ln Q) Lr) Z F< " U_ Z CL � e­% >� , rt) C)� U CL -I < 00 Z § E WZ C:) LU _J C) M 3:5 F�E Z g Z g8o, �Euz =ZZ Se 8 0 U" Cc Z 8 W LA Z Z U.1 0 M: Z C) Z 0 Ln Z 0 Lr) — M r#-4 UJ > Z 0 < uJ U Z 9 Lu 0 OZ 01. U. or- 2�!� Z LLJ �i<z<< F- 3w: 0 Z Lr) ZM 8 Z 0 Lu 110 2: < 8 01% < Lu Z Z CY Z (1) Z 0 C13 UJI 0 r� 15 rn a— U*) SCALE AS NOTED DATE 2/24/2014 TECH: MIAMES VERSION NO - 10 SHEET NO. 2.0 STAIR CALCUTIONS: TOTAL RISE = W-0 3/4" (116) RISERS AT 7 9/16" 10" TREADS w/ 1"NOSING INTERIOR ELEVATIONS SCALE: 1/2"=V-0" Residential section R311.7 Riser height: The maximum riser height shall be 73/4". The greatest riser height within any flight of stairs shall not exceed the smallest by more than �3/8". to conform to MIN. (3) 2x STUDS REQ'D @ END OF LANDING BELOW HDR. BEAM. Tread depth. The minimum tread depth shall be 10". The greatest tread depth within any flight of stairs shall not exceed the smallest by more than %". Nosings. The radius of the nosing shall be no greater that %16"- Solid riser nosings shall not be less than 1/4" but not more than 1Y4". The greatest nosing projection shall not exceed the smallest by more than Y2". Beveling of nosings shall not exceed Handrails. Handrails shall be provided on at least one side of each continuous run of treads or flight with four or more risers. Handrail height, measured vertically from the sloped plane adjoining the tread nosing, or finish surface of ramp slope, shall be not less than 34" and not more then 38". Handrails adjacent to a wall shall have a space of not less than %"between the wall and the handrails. Grip -size. Handrails with a circular cross section shall have an outside diameter of at least 1 1/4" and not greater than 2" or provide equivalent graspavility in compliance with FBC 5th Edition (2014) Residential Section R311.7.8.3. Guards. Guards shall be located along open -sided walking surfaces, including stairs, ramps and landings, that are located more than 30" and shall be not less than 36". Required guards shall not have openings from the walking surface to the required guard height which allow passage of a sphere 4" in diameter. Winders. Winder treads shall have a minimum tread depth of 6" at the narrow end and shall have a minimum tread depth of 10" at the intersections with the walkline (12" from the narrower side). R302.7 Under -Stair Protection. Enclosed accessible space under a stairway shall be protected with 1/2" gyp. k STAIR SECTION SCALE: 1/2"=V-0" KITCHEN 8-541 KITCHEN ISLAND SCALE: N.T.S. 9'-0" MAX LANDING LENGTH 2X8 #2 SYP JOISTS @ LANDING @ 16" O.C. wl SIMPSON A35 CLIP OR LUS26 HANGER TO LEDGER 2x12 HDR. w/ (3) 2x STUDS AT EA. END FOR BEARING STANDARD (3) 2X12 STRINGERS W/ SIMPSON A35 CLIP TO HDR. 1x TREADS (TYP.)--\-, CONT. HANDRAIL GENERAL LANDING FRAMING INFO. 9 L= KITCHEN THRUST BLOCK SECURED TO SLAB w/ 1/4"X3 1/2" TAPCONS @ 16" O.C. PLYWOOD @ LANDING BATH 2 2x8 LEDGER #2 SYP w/ (3) 16d NAILS TO STUD @ 16" O.C. U') I SEE PLAN FOR LANDING DEPTH i 60 Aq a PRE-ENG FLOOR JOIST W/ (2) 0 0 0 Z Z cog Z U) Z Q) C_A) LU 0 LU 0 V) 04 C) (D cl) 0) co LU a W cl) E Ct$ 'a Cl) = C14 8 6,0. Qj :S u- co c). 5,6!� 0 1,D 0) -r, -, U.) 0 q. a 0. ---:, < CM < 0 A c a D. Lo R, cc *L0 X Z 0 __J *SkA Lu C9.0 L 111 r C, 4 F F E To the best of the Engin4Pf, M nd belief, the structural plans an hrlc� within these drawings comply with the Florida Building Code 5th Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. c) C�' Z 0 #-a C) un C) V) fU LO tn Z Ln Q) Lr) Z F< " U_ Z CL � e­% >� , rt) C)� U CL -I < 00 Z § E WZ C:) LU _J C) M 3:5 F�E Z g Z g8o, �Euz =ZZ Se 8 0 U" Cc Z 8 W LA Z Z U.1 0 M: Z C) Z 0 Ln Z 0 Lr) — M r#-4 UJ > Z 0 < uJ U Z 9 Lu 0 OZ 01. U. or- 2�!� Z LLJ �i<z<< F- 3w: 0 Z Lr) ZM 8 Z 0 Lu 110 2: < 8 01% < Lu Z Z CY Z (1) Z 0 C13 UJI 0 r� 15 rn a— U*) SCALE AS NOTED DATE 2/24/2014 TECH: MIAMES VERSION NO - 10 SHEET NO. 2.0 STAIR CALCUTIONS: TOTAL RISE = W-0 3/4" (116) RISERS AT 7 9/16" 10" TREADS w/ 1"NOSING INTERIOR ELEVATIONS SCALE: 1/2"=V-0" Residential section R311.7 Riser height: The maximum riser height shall be 73/4". The greatest riser height within any flight of stairs shall not exceed the smallest by more than �3/8". to conform to MIN. (3) 2x STUDS REQ'D @ END OF LANDING BELOW HDR. BEAM. Tread depth. The minimum tread depth shall be 10". The greatest tread depth within any flight of stairs shall not exceed the smallest by more than %". Nosings. The radius of the nosing shall be no greater that %16"- Solid riser nosings shall not be less than 1/4" but not more than 1Y4". The greatest nosing projection shall not exceed the smallest by more than Y2". Beveling of nosings shall not exceed Handrails. Handrails shall be provided on at least one side of each continuous run of treads or flight with four or more risers. Handrail height, measured vertically from the sloped plane adjoining the tread nosing, or finish surface of ramp slope, shall be not less than 34" and not more then 38". Handrails adjacent to a wall shall have a space of not less than %"between the wall and the handrails. Grip -size. Handrails with a circular cross section shall have an outside diameter of at least 1 1/4" and not greater than 2" or provide equivalent graspavility in compliance with FBC 5th Edition (2014) Residential Section R311.7.8.3. Guards. Guards shall be located along open -sided walking surfaces, including stairs, ramps and landings, that are located more than 30" and shall be not less than 36". Required guards shall not have openings from the walking surface to the required guard height which allow passage of a sphere 4" in diameter. Winders. Winder treads shall have a minimum tread depth of 6" at the narrow end and shall have a minimum tread depth of 10" at the intersections with the walkline (12" from the narrower side). R302.7 Under -Stair Protection. Enclosed accessible space under a stairway shall be protected with 1/2" gyp. k STAIR SECTION SCALE: 1/2"=V-0" KITCHEN 8-541 8-541 NOTE: • FIN. TO HAVE TRADITIONAL LOOK & SMOOTH FINISH • FOAM/ EPS MATERIAL IS ACCEPTED 1/2"THICK W T z 31' FF]1J - 2 0 C�l 1"RAISED STUCCO BAND 2" RAISED STUCCO BAND L 1/2 OF L V'VINDOW WIDT1­1 !4 to (0 ENTRY COLUMN DETAIL. —loo Millt M T.O.P F`� HDR HGT. I 12 5 12 16" x 28" GABLE END VENT 12 5 1 " x 4" SMOOTH TEXTURED TRIM / BAND - -------------------- I �� ] �� 11 �� FRONT ELEVATION - B SCALE: 1/4"=V-0" LEFT ELEVATION - B SCALE: 1/4"=V-0" T.O.P. HDR HGT. 2nd FIN. FLR. T.O.M. HDR HC F.FL. 9: M I A General Notes ROOF CRITERIA: 12" OVERHANG U.N.O. PLUMB CUT FASCIA ROOF PITCH PER ELEVATION .G.C. VERIFY ROOF PITCH" ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE CONTRACTORS RESPONSIBILITY TO VERIFY ROOF SLOPE REQUIREMENTS WITH TRUSS MANUFACTURER. "ELECTRICAL SPECIFICATION NOTES" ELECTRICAL CONTRACTOR MUST VERIFY WITH THE SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT FIXTURES SHOWN ARE FOR LOCATION PURPOSES. Exterior Covering R703.6 Exterior plaster. Installation of these materials shall be in compliance with ASTIM C 926 and ASTM C 1063. R703.6.1 Loth. All Lath and lath attachments shall be of corrosion -resistant materials. Attached per ASTM C 1063. R703.6.2 Plaster. Plastering w/ portland cement plaster shall be not less than three coats when applied over metal lath or wire lath and shall be not less than two coats when applied over masonry, concrete. R703.6.3 Water-Resisitive Barriers. Water-resisitive barriers shall be installed where cement plaster (stucco) is to be applied over wood -based sheathing, shall include a water -resistive vapor -permeable barrier. The individual layers shall be installed independently such that each layer provides a separate continuous plane and any flashing intended to drain to the water -resistive barrier is directed between the layers. The barriers shall consist of one of the following. 1. Two layers of an approved water resistant barrier material in accordance With R703.2. 2. One layer of an approved water -resistive barrier (paperbacked stucco lath) over an approved synthetic house wrap. R703.8 Flashing. Approved corrosion -resistant flashing shall be applied shingle -fashion in a manner to prevent entry of water into the wall cavity or penetration of water to the building structural framing components. Flashing shall be installed at the following locations. • Exterior window/door openings. • Intersection of chimneys or other masonry contructions with frame walls. • Under and at the ends of masonry, wood or metal copings and sills. • Continuously above all projecting wood trim. • Where exterior porches, decks or stairs attach to a wall or floor assembly of wood -frame construction. • At wall and roof intersections • At Built-in gutters. _J Attic Ventilation Attic Ventilation to be in compliance with the Florida Building Code 5th Edition (2014) Residenfial R806. The Minimum net free ventilating area shall be 1/150 of the area of the vented space. The ventilating area may be reduced to 11300 provided that at least 40% but no more then 50% of the required ventilation is provided in the upper portion ol the space to be ventilated.Upper ventilators shall be located no more than 3 feet (measured vertically) below the ridge or highest point of the space, with the balance of the required ventilation provided by save or cornice vents. -CALCULATIONS BASED ON THE FOLLOWING VALUES, SEE ROOF PLAN ­ (Values to be verified with Manufacturer Specifications) RIDGE VENTS 15 SQ. IN. OF NET FREE AREA / LINEAR FT. OFF -RIDGE VENTS 138 SQ. IN. OF NET FREE AREA I UNIT SOFFIT VENTS 7 SO. IN. OF NET FREE AREA / SQ. FT. *If not enough vented soffit is provided due to fire protection, the contractor shall use the following approved vents: * LOMANCO DECK -AIR (Shingle Roof) - 9 SQ. IN. OF NET FREE AREA/ FT. "Formula: (Sq. Ft. Soffit Needed) x 7 = (Sq. In. Needed) / 9 = (Unear Ft of Deck -Air Needed) e O'HAGIN (Tile Roof)l - 86.25 SQ. IN. OF NET FREE AREA / VENT "Formula: (Sq. Ft. Soffit Needed) x 7 = (Sq. In. Needed) / 86.25 = Amount of O'Hagin Vents Needed 0 LO �; 0 0 V) (D Q) U—) 4--J LU U 0 LU un01- 1­ 0 U) V) 0 0 Ir', M C\l E 0 4) Cl) M co C ca co M 'a ce) 6,C N C) a) u- 00 - co 0 CU — _�d r.- a 0f ) -,e 0 < U) 0. C) Lo 0 V "t 0- 0) < 8 D, 0 Cc CD X: S E_ LO d0co 21-1;� cs U- 01 0. 0 U1 Lu. La lox In a gg S NMI F 0 ES.2 z ......... IL W1 O,FESS� To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code 5th Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. CD Z r-J 0 w r-, c) > C�' 4-J (n M Ln < -0 z a- U) r ',I- V) 0 N (1) — Lr) CL OC) z z E z C:� WLU _J C:) 0z 0 z z 0 QGE Z 0 z 0 C) z ci uz� D z z in uu Z < Lu �z LJLJ C-0 8 IUA, _J U.J z 8 Ln UJ z Z� Z 0 C) 4 Ln V5 0 0 r*4 m U V) 0 z 11-1 R ZO < 1, t. 0 UO2 ro- ZW uJ C,)� z < < u, ce z z r"4 Ce u- ILL! _J Ln LLJ 2: di < Doz <E5 l-; 0 0 R �2 W P, 110 0) < Z z L_ 0�,z < c, D Cy Ln 0 Z J LIJ Z 0 z uJ a- I U0 TZ SCALE AS NOTED DATE 2/24/2014 TECH: M3AMES VERSION No' 10 SHEET NO. 3.1 Z IGO Z C� 00 F- 80 . -1 cliv o? BO C� F_ r___3 12 5 12 _____J5 T.O.P. HDR HGT. — — — — — — — — — — — — — — — — — - — — — — — — — — — — — — — — — — — — — — L — — — — — — — — — — — — — — — — — — — — T.O.P. HDR HGT . . . . . . . . . 2nd FIN - — — — — — — — — FLR. T.O.M. HDR HGT - — — — — — — — — F.FL . . . . . . . . . REAR ELEVATION - B SCALE: 1/4"=V-0" RIGHT ELEVATION - B SCALE: 1/4"=V-0" General Notes ROOF CRITERIA: * 12" OVERHANG U.N.O. * PLUMB CUT FASCIA ROOF * PITCH PER ELEVATION **G.C. VERIFY ROOF PITCH" ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE CONTRACTORS RESPONSIBILITY TO VERIFY ROOF SLOPE REQUIREMENTS WITH TRUSS MANUFACTURER. "ELECTRICAL SPECIFICATION NOTES" ELECTRICAL CONTRACTOR MUST VERIFY WITH THE SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT FIXTURES SHOWN ARE FOR LOCATION PURPOSES. Exterior Covering R703.6 Exterior plaster. Installation of these materials shall be in compliance with ASTM C 926 and ASTM C 1063. R703.6.1 Lath. All Lath and lath attachments shall be of corrosion -resistant materials. Attached per ASTM C 1063. R703.6.2 Plaster. Plastering wl portland cement plaster shall be not less than three coats when applied over metal lath or wire lath and shall be not less than two coats when applied over masonry, concrete. R703.6.3 Water-Resisitive Barriers. Water-resisitive barriers shall be installed where cement plaster (stucco) is to be applied over wood -based sheathing, shall include a water -resistive vapor -permeable barrier. The individual layers shall be installed independently such that each layer provides a separate continuous plane and any flashing intended to drain to the water -resistive barrier is directed between the layers. The barriers shall consist of one of the following. 1. Two layers of an approved water resistant barrier material in accordance with R703.2. 2. One layer of an approved water -resistive barrier (paperbacked stucco lath) over an approved synthetic house wrap. R703.8 Flashing. Approved corrosion -resistant flashing shall be applied shingle -fashion in a manner to prevent entry of water into the wall cavity or penetration of water to the building structural framing components. Flashing shall be installed at the following locations. • Exterior window/door openings. • Intersection of chimneys or other masonry contructions with frame walls. • Under and at the ends of masonry, wood or metal copings and sills. • Continuously above all projecting wood trim. • Where exterior porches, decks or stairs attach to a wall or floor assembly of wood -frame construction. • At wall and roof intersections • At Built-in gutters. Attic Ventilation Attic Ventilation to be in compliance with the Florida Building Code 5th Edition (2014) Residential R806. The Minimum net free ventilating area shall be 1/150 of the area of the vented space. The ventilating area may be reduced to 1/300 provided that at least 40% but no more then 50% of the required ventilation is provided in the upper portion the space to be ventilated.Upper ventilators shall be located no more than 3 feet (measured vertically) below the ridge or highest point of the space, with the balance of the required ventilation provided by eave or cornice vents. -CALCULATIONS BASED ON THE FOLLOWING VALUES, SEE ROOF PLAN" (Values to be verffied with Manufacturer Specifications) • RIDGE VENTS 15 SO. IN. OF NET FREE AREA / LINEAR FT. • OFF -RIDGE VENTS 138 SQ. IN. OF NET FREE AREA / UNIT • SOFFIT VENTS 7 SQ. IN, OF NET FREE AREA / SQ. FT. *If riot enough vented soffit is provided due to fire protection, the contractor shall use the following approved vents: • LOMANCO DECK -AIR (Shingle Roo� - 9 SQ. IN. OF NET FREE AREA / FT. Formula: (Sq. Ft. Soffit Needed) x 7 = (Sq. In. Needed) 19 = (I-Inear Ft. of Deck-AIr Needed) • O'HAGIN (Tile Roof) - 86.25 SQ. IN. OF NET FREE AREA/ VENT **Formula: (Sq. R. Soffit Needed) x 7 = (Sq. In. Needed) / 86.25 = Amount of allagin Vents Needed 0 (D !� z Cl) 0 —0 ;;7 (0 :7 � < I tj CIL z _J LU U ILL! 0 0� F- E 0 00 C`4 0 LU E —8 ago 0) C0 C: C0 ce) 2 �0 m 0 C) Can) 0) c: ILL 00 15 C6 0 -, 4) Ne < 0 05 0. 8 LO 0 V a CL < A I D. C, 11, D, C r-_ to M \ISO CN 9;E LaE, — .,r- apCUM u J< E 0 A oo To the best of the Engine nation, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code 5th Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. C:) 0 Z 0 0 4-) CD V) 1,0 > C:) ry) U0 c) ro In < 0 z CL V) e-, (L) -2 LA L_ LL CL ro 6- CL 00 z <z E z M _J C� W Lu Z� < W � 9� Z80 0 �E:5 z z 0 LU Z 0�uj :> LLJ Lu �i LJJ Z 0 Lr) LU U z z z 0 -a N C) — V) ro Lr) C/) E 0 W M 0 U cr_ LLJ 8 < LU r- R Z. X<: 6 P X 0 OR -R r4 Cr U or_'�'L 003k _� z LU czl;� < Ce < W �U_ z z z LU In 0< ILLI 2: di 8 =Z, -8 z 8 op 11.0 0) < < z F_ �v 8 < I z z Z M < 01 V) U) Z 0 M 0 LU SCALE AS NOTED DATE 2/24/2014 TECH: MIAMES VERSION NO' 10 SHEEr NO. 3.2 i;. �m E-1-0-aR, —11, -1.11 1 A A .11 , 1 11 1 1 1 — .1 1 1 ELECTRICAL SPECIFICATION NOTES: ELECTRICAL CONTRACTOR MUST VERIFY WITH THE SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT FIXTURES SHOWN ARE FOR LOCATION PURPOSES. 200A INDOOR PANEL CENTER #15 copper to lights & outlets NEMA 1 200 AMP #12 copperto 20 amp ckts #10-2 copper to WH #10-3 copper to Dryer MAIN A-L or 4/0 SER Alu 0 200 amp 150 amp ===1F210 Disconn POWER CO. FEED _Inset INTERSYSTEM 4 Bare Cu Ground BONDING *4 GROUNDING WIRE TERMINATION PER WITH CODE APPROVED NEC 08, 250.94 CLAMP PER 250.50 AND 250.52 OF THE 2011 NEC. GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2011, LOCAL CODES AND THE LOCAL POWER CO. 1 . Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF (general) kitchen 44" AFF bathroom 39" AFF laundry room 36" AFF exterior waterproof 12" AFF garage general purpose 42" AFF range 2" AFF 2. All trim plates & devices to be ganged, where possible. 3. Electrical switches to be at 42" centerline above finished floor. 4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the installation & sizing of all electrical, wiring & accessories. 5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. 6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch circuits in all dwelling units per NFPA 70 and the 2011 NEC. 7. Provide Tamper Resistant Receptacles as required by the 2011 NEC, 406.11 8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and vapor detector sensor, according to the installation. 9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a Nationally Recognized Testing Laboratory. 10. Keep all smoke detectors minimum of 36" from bathroom doors 11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be equipped with a monitored battery backup. 12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits is not acceptable. 13. All doors and windows providing direct access from the home to the pool shall be equipped with an exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning when the door or window are opened.. 14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' if the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacles outlests shall not be required on a wall directly behind a range or sink to fulfill the requirement for an outlet every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and 18" for sinks and ranges installed in corner counters. I ELECTRICAL KEY I I 0=� tkz�;,- DUPLEX CONVENIENCE OUTLET I Z±�, PEPP DUPLEX OUTLET ABOVE COUNTER �I@W.P. WEATHERPROOF DUPLEX OUTLET GROUND FAULT INTERRUPTER DUPLEX OUTLET HALF -SWITCHED DUPLEX OUTLET SPECIAL PURPOSE OUTLET DUPLEX OUTLET IN FLOOR 220 VOLT OUTLET WALL SWITCH THREE-WAY SWITCH ?4 FOUR-WAY SWITCH $R RHEOSTAT SWITCH CEILING MOUNTED LIGHT FIXTURE WALL MOUNTED LIGHT FIXTURE @) RECESSED LIGHT FIXTURE LIGHT FIXTURE WITH PULL CHAIN TRACK LIGHT FLOURESCENT LIGHT FIXTURE EXHAUSTFAN EXHAUST FAN/LIGHT COMBINATION MQ ELECTRIC DOOR OPERATOR (OPTIONAL) PH] CHIMES (OPTIONAL) El PUSHBUTTON SWITCH (OPTIONAL) SMOKE DETECTOR SMCKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) TELEPHONE (OPTIONAL) TELEVISION (OPTIONAL) 2 (2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60- A.F.F. THERMOSTAT ELECTRIC METER owl ELECTRIC PANEL DISCONNECT SWITCH SPEAKER (OPTIONAL) 1> ROUGH -IN FOR OPT. CEILING FAN /> CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR </ OPT. CEILING FAN G9 (1) PHONE LINE, (1) DATA PORT DEDICATED RECEPTACLE FOR MICROWAVE RANGE HOOD PER SPECS VERIFY METER LOCATION WITH BUILDER H.B. GFI V FI FI: V VERIFY LOCATION IRRIGATION r OPT. ELECTRICAL PANEL — — — — — — — — — — — — REF. GFI @ 44" A.F.F. I L T— KITCH EN W D .1P —QG FF I Li Lil GFI FOR I GFI @ 44" GAR. DOOR GFI A.F.F. WP GFI 9 2 CAR GARAGE PATIO DINING ROOM ,/PENDANT AS 0 1 L PER SPECS GFI @ 44" Cq A.F.F. Cl) W.H. J, CE `4P Z7 FOYER TR)�I -db- ----------- rn qp WP 7 GFI ROUGH -IN FOR 01, OPT. CLG. FAN/ 1000 LIGHT PRE -WIRE FLEX WP FAMILY ROOM — TO 2NDCj� GFI 317-1 FLR. I 100, ROUGH -IN FOR OPT.CLG.FAN/ DISCONNECT LIGHT PRE -WIRE 7/— I 1—, 4 (C 0 ND. db LVTT7TTTTIIIIIIIIIIIIIIIIIIIIilililI 1111111111 1111mill,11+111+111111111 111111711111111111111111771111111111 H.B. MAIN FLOOR ELECTRICAL PLAN SCALE: Y4"= V-0" (D Ul) (D Q) C—J0 4—J LU ru 0 LU 0 CO C\I a) co 0) M C M co E 0 cc "0 n 6'i= N 0 to C) LL 00 :3 0_,[,_ U5 -�e < 0 LO 0 -'T N C B D C La 6 010 Ci Z Cql` W 4W 2 'T __A __j LL Lj-__j I U- 08% .a LL 0 ,= 0 W CL CH LLI PE, 0 c� (5 '6 of-- 0 E B 0 2 Z W 012 < To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code 5th Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. C:) 0 Z C-4 0 cu f 0­1 4-J C:) V) 1 53 �0 C:) > V) rn C) M U-) f0 Lr) :2. q1- Z cl. w (A 0 rl� a) — Ln L- LL CL o-'s , 170 ce U a- OC) Z < Z § E Z 170 Lu C) —.1 W 0, U0, Z Z 17 Z >- < C, 0 U Z Z Z Lu Z � LH 8 �y u­ 8 " 03 l- EE 0- Lon Z Z Lr) 0 U Z uj Z 0 -0 LU Ln fu Lr) LU CC Z 0 0 U 0 LL LU < F0 0 Z 0- rj 0 < Z 1Z < < F- LU OW 0 cg 1) Z 0 Z LU Ln 6j CY u- u" 20: �Z- N-c - 2: < Z on OZ8 2 w N < LLI 8 Z Z Z tu— (A Z 0 LU < Ln Z LU 17-11 13- U0 In SCALE AS NOTED DATE 2/24/2014 TECH: WAMES VERSION No' 10 SHEEr NO. 4.0 I ELECTRICAL SPECIFICATION NO -TES: ELECTRICAL CONTRACTOR MUST VERIFY WITH THE SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT FIXTURES SHOWN ARE FOR LOCATION PURPOSES. 200A INDOOR PANEL CENTER 015 copper to lights & outlets NEMA 1 200 AMP #12 copper to 20 amp ckts #10-2 copper to WH #10-3 copper to Dryer MAIN 0 2/0 or 4/0 SER Alu 200 amp 150 amp Isconnect POWER CO. FEED _It INTERSYSTEM 4 Bare Cu Ground BONDING [;P #4 GROUNDING WIRE TERMINATION PER WITH CODE APPROVED NEC 08, 250.94 CLAMP PER 250.50 AND 250.52 OF THE 2011 NEC, GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2011, LOCAL CODES AND THE LOCAL POWER CO. 1 . Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF (general) kitchen 44" AFF bathroom 39" AFF laundry room 36" AFF exterior waterproof 12" AFF garage general purpose 42" AFF range 2" AFF 2. All trim plates & devices to be ganged, where possible. 3. Electrical switches to be at 42" centerline above finished floor. 4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the installation & sizing of all electrical, wiring & accessories. 5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. 6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch circuits in all dwelling units per NFPA 70 and the 2011 NEC. 7. Provide Tamper Resistant Receptacles as required by the 2011 NEC, 406.11 S. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and vapor detector sensor, according to the installation. 9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a Nationally Recognized Testing Laboratory. 10. Keep all smoke detectors minimum of 36" from bathroom doors 11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be equipped with a monitored battery backup. 12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits is not acceptable. 13. All doors and windows providing direct access from the home to the pool shall be equipped with an exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning when the door or window are opened.. 14. Add GFC1 protection to receptacles in laundry rooms and utility rooms of dwellings where installed Within 6' if the outside edge of a sink. This would include the receptacle Installed for a washing machine. Receptacles outlests shall not be required on a wall directly behind a range or sink to fulfill the requirement for an outlet every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and 18" for sinks and ranges installed in corner counters. I ELECTRICAL KEY I Lj=� . DUPLEX CONVENIENCE OUTLET DUPLEX OUTLET ABOVE COUNTER PE5w.P. WEATHERPROOF DUPLEX OUTLET OG.F.I. GROUND FAULT INTERRUPTER DUPLEX OUTLET N�-- HALF -SWITCHED DUPLEX OUTLET SPECIAL PURPOSE OUTLET DUPLEX OUTLET IN FLOOR 220 VOLT OUTLET WALL SWITCH $3 THREE-WAY SWITCH 6. _�)4 FOUR-WAY SWITCH $R RHEOSTAT SWITCH CEILING MOUNTED LIGHT FIXTURE WALL MOUNTED LIGHT FIXTURE @) RECESSED LIGHT FIXTURE LIGHT FIXTURE WITH PULL CHAIN TRACK LIGHT FLOURESCENT LIGHT FIXTURE EXHAUSTFAN W—W EXHAUST FANILIGHT COMBINATION mr) ELECTRIC DOOR OPERATOR (OPTIONAL) RCH CHIMES (OPTIONAL) El PUSHBUTTON SWITCH (OPTIONAL) SMOKE DETECTOR SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) TELEPHONE (OPTIONAL) TELEVISION (OPTIONAL) 2 (2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. THERMOSTAT ELECTRIC METER owl ELECTRIC PANEL DISCONNECT SWITCH SPEAKER (OPTIONAL) 1/\ 1> ROUGH -IN FOR OPT. CEILING FAN CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR </ OPT. CEILING FAN (1) PHONE LINE, (1) DATA PORT RECEPT. FC L L _j UPPER ELECTRICAL PLAN SCALE: )/4"=V-0" (D 0 CO Q V) (D Q) C—/) 4—J LU 0 LU I­ 0 Ce) V) F___ 00 Fn r- U 04 M E 0) C0 I= 04 8 oil 000 M Qi r- FL Co ci!� 0) -.e CL 6 Lo 0 't < 0 tm q 0. ch< N C B-D-c to M C14 LO zi; M CN L0 12 00, 4;; 6 CS Z Lo C0 0 0 C-4 04 r- Z ;Z W 41F 1— .9 2) T c jL - 0 .1 . - LU C' 14 Lu L� a_ LL c, < CL — Z ot <= Z 0 L. N j5 In to 9 M Z 44 31 E I.- P 44 c, Is -1 8 N To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code Sth Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. CD C) Z r-4 0 (3) r-, 4-0 C=) 5 t�o c) > V) M ro CD U-) ro Lr) Z '2'�: < -0 0- ul C: (n 0 a) — Lr) L_ < L.L CL I re) U CL Z < OC) Z § E Z C) WIJj _j C:) 01 Z 1 EZ80 0 U, = CL ZZ Z< �E.,Z Q � U., 0Z Lu on 8 V,) Z Z 8 Lr) c) Z Z Z LU L2 Lr) _j LU 0 0 U U') 0 LLJ _j LL. 0 Z IU 0 0 U, 0 U C� E < < <Z u, �: 2: 80 mgce IM Z 0 Z Lu a u- U-1 _j Ln L]j C) Z g T, :,:) 0 Z 0 uJ u_ 14 < 01 Z i� < uJ Z Q� re) Z ITJ I CY < V) L0 Z M Z LU �O <M Z LU SCALE AS NOTED DATE 2/24/2014 TECH: WAMES VERSION NO - 10 SHEET NO. 4.1 f . I . 1� I , � I I , . � -F-U7, FT-, f , i I I.. 1� � Al 4 1 . I I I I I I I I I LM VENTED SOFFIT 40 SQ. FT. ®r 6A id- 0 -16DIIAl 01 LO 5:12 �Iw iL LO 10 401 COND. VENTED SOFFIT 42 SQ. FT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . o . . . . . . . . . . - 1 6 o * I o o o * # # * * * # I I I I I 1 6 1 1 1 o I * 4 . . . . . . . . . . . . . . . . . . o . . o . . . . . . . . . . . ZONE-2 ATTIC SPACE 1533 SQ. FT. 19:12 SLOPE 9 010 Cl- 0 -J (0 C14 r U) 4'-O'ROOF VENT I 4'-O'ROOF VENT 1 =3 19, 5:12 SLOPE, RIDGE VENT LLJ (L C14 aiii ii, r LLI (L 0 04 7: 1 1 LU a. 0 -J 0) C14 ------- ---- - ................................. ............................. 7. ............................. 07. .............. VENTED SOFFIT 40 SQ. FT. 12 12 ATTIC VENTILATION CALCULATIONS - B ATTIC VENTILATION REQUIRED UPPER VENTILATION PROVIDED 1/150 Rule (No Upper Ventilators 1/300 Rule Ridge Vent Amt Off -Ridge Req.) (Must Provide Upper Ventilators) (Ft.) Amt. Total Ventilation ATTIC Provided SPACE SQ. FT. Total SQ. SQ. FT. SO. IN. of by Upper SO. IN. of of vented IN. Of of ventilation to SQ. IN. of SQ. IN. of Ventilators ventilation Soffit required ventilation vented soffit be provided by upper Ventilation Ventilation (See Elev) needed required needed ventilators I Main 0.000000 0.000000 Floor 0 0 0 0 0 0 0.0 0.0 0.0 (Zone 1) Upper 9 2.000000 Floor 1533 1472 210 736 53 368 411.0 276.0 (Zone 2) 135.0 **NOTE** GENERAL CONTRACTOR MUST ENSURE THAT PROPER VENTILATION IS PROVIDED AT EAVES/SOFFITS AS REQUIRED BY FBC 6th ED. RESIDENTIAL. VENTED SOFFIT LEGEND IF SOFFIT IS LABELED AS 'NON -VENTING" FIRE PROTECTION WILL BE INSTALLED AS REQUIRED BY SECTION R302 OF THE FBC 5th EDITION (2014) RESIDENTIAL. IF LABELED AS'VENTED", NO FIRE PROTECTION WILL BE REQUIRED. ............... VENTED SOFFIT VENTED SOFFIT 19 SQ. FT. ZONE-1 ATTIC SPACE 35 SQ. FT. VENTED SOFFIT 29 SQ. FT. SCALE: J/4"=V-0" General Notes ROOF CRITERIA: 0 12" OVERHANG U.N.O. 0 PLUMB CUT FASCIA ROOF 0 PITCH PER ELEVATION **G.C. VERIFY ROOF PITCH** ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE CONTRACTORS RESPONSIBILITY TO VERIFY ROOF SLOPE REQUIREMENTS WITH TRUSS MANUFACTURER. "ELECTRICAL SPECIFICATION NOTES" ELECTRICAL CONTRACTOR MUST VERIFY WITH THE SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT FIXTURES SHOWN ARE FOR LOCATION PURPOSES. Exterior Covering R703.6 Exterior plaster. Installation of these materials shall be in compliance with ASTM 0 926 and ASTM C 1063. R703.6.1 Lath. All Lath and lath attachments shall be of corrosion -resistant materials. Attached per ASTM C 1063. R703.6.2 Plaster. Plastering w/ portland cement plaster shall be not less than three coats when applied over metal lath or wire lath and shall be not less than two coats when applied over masonry, concrete. R703.6.3 Water-Resisitive Barriers. Water-resisitive barriers shall be installed where cement plaster (stucco) is to be applied over wood -based sheathing, shall include a water -resistive vapor -permeable barrier. The individual layers shall be installed independently such that each layer provides a separate continuous plane and any flashing intended to drain to the water -resistive barrier is directed between the layers. The barriers shall consist of one of the following. 1. Two layers of an approved water resistant barrier material in accordance with R703.2, 2. One layer of an approved water -resistive barrier (paperbacked stucco lath) over an approved synthetic house wrap. R703.8 Flashing. Approved corrosion -resistant flashing shall be applied shingle -fashion in a manner to prevent entry of water into the wall cavity or penetration of water to the building structural framing components. Flashing shall be installed at the following locations. • Exterior window1door openings. • Intersection of chimneys or other masonry contructions with frame walls. • Under and at the ends of masonry, wood or metal copings and sills. • Continuously above all projecting wood trim. • Where exterior porches, decks or stairs attach to a wall or floor assembly of wood4rame construction. • At wall and roof intersections • At Built-in gutters. Attic Ventilation Attic Ventilation to be in compliance with the Florida Building Code 5th Edition (2014) Residential R806. The Minimum net free ventilating area shall be 1/150 of the area of the vented space. The ventilating area may be reduced to 1/300 provided that at least 40% but no more than 50% of the required ventilation is provided in the upper portion of the space to be ventilated. Upper ventilators shall be located no more than 3 feet (measured vertically) below the ridge or highest point of the space, with the balance of the required ventilation provided by eave or cornice vents. "CALCULATIONS BASED ON THE FOLLOWING VALUES, SEE ROOF PLAN ­ (Values to be verified with Manufacturer Specifications) • RIDGE VENTS 15 SQ. IN. OF NET FREE AREA / LINEAR FT. • OFF -RIDGE VENTS 138 80. IN. OF NET FREE AREA / UNIT • SOFFIT VENTS 7 SQ, IN. OF NET FREE AREA / SQ, FT. *If not enough vented soffit is provided due to fire protection, the contractor shall use the following approved vents: • LOMANCO DECK -AIR (Shingle Roof) - 9 SQ. IN. OF NET FREE AREA / FT. Formula: (Sq. Ft. Soffit Needed) x 7 = (Sq. In. Needed) / 9 = (Linear Ft. of Deck -Air Needed) • O'HAGIN (Tile Roo� - 86.25 SQ. IN. OF NET FREE AREA / VENT **Formula: (Sq. Ft Soffit Needed) x 7 = (Sq. In. Needed) / 86.25 = Amount of O'Hagin Vents Needed 0!�G z M 9 z (D rL U) z V) 0 (1) C—f) u-1 U 0 LLJ V) 1` 0 to W ce) C14 E 0 W ce) 0) cl) C Co Cl) T :2 M 0 8 c" q a) 0 00 0 C6 f L, a) < 1- _,,� 05 CL 0 CL 0)< 0 A I N \\ C,1 -,-ere ` 01� 8 Do V tAza 4�c&g., Lo r% ci d, :§.lD,-,4 mt��, 'IVP [z _,.0 ­-J V) 0 A yj� ILL 0 z < A LL V<t,mt ip LU N M'E E, r- 0 I= LJ 0 4) �02 To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code Sth Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. C:) Z f-4 0 (3) 4-J C:) , 5 "o c) > (/) ro rn c) V) -fu Lr) a CL (n V- r 2: (A 0 N Q) — Ln < U­ F- CL>� fa < U CLOD z E Z 7. § fo -J CD W LLJ C:� t.0 01 0 Ln cK �.> , 0 z z < Z< zz <z Z, 8 8 z 10 tH Z Z 8 L0 Z z 15 z 0 -0 CL 22 V) 3: Lr) 0 > (N Z U —J CL UL > 0 �0 Z < 0 0 S 5 0 2 r-4 0 M- T < < 0 LJJ r-J 0 ce z LU r1i Ln Lij = 2 cy L'. 0, 1z ff� -J T-4 LIJ 2: 2: < � 0= OZ8 0!� z i58 Ce u z z t7u CY ur) Z 0 On 0 LIJ W z Lu U0 z m SCALE AS NOTED DATE 2/24/2014 TECH: IVIJAIVIES VERSION No' 10 SHEET NO. 5.0 E: C M 431-0" TYP @ 2 STORY H.B. t NOTE: • WHERE PROJECT IS TO BE LOCATED IN KNOWN RADON GAS PREVALENT AREAS, APPENDIX "E" OF THE FBC 5th EDITION (2014) BUILDING IS TO BE IMPLEMENTED. CONCRETE STRENGTH IN THESE AREAS TO BE A MINIMUM OF 3000 P.S.I. THEREFORE, ANY AND ALL NOTES ON THESE PLANS THAT INDICATED 2500 P.S.I. SHALL BE REPLACED WITH 3000 P.S.I. FOR THE CONCRETE STRENGTH • SEE SHEET SN FOR SOIL & TERMITE NOTES. BORATE / BORACARE TREATED LUMBER IS AN ALTERNATE TERMITE PROTECTION TO SOIL POISONING W.W.M. PLACED IN —1 /8" SAWCUT x 1/4 SLAB UPPER 1/3 OF SLAB THICKNESS WHERE OR FIBERMESH SHOWN ON REINF. SEE PLAN. FOUNDATION PLAN '7� U u CONTROL JOINT DETAIL. SCALE: 1 1/2"=V-0" . . . . . . . . . . . . . . . . . . . ............ .......... C? F 2STDRY LO "—#5 CONT REINF. SEE (2) #5 REBAR FND. FOR QUANTITY /CC VERTICALS w/ in %, �3 FILLED CELL #5 X 25" X 25" CORNER BAR ONE FOR EA. IF-t 71 k� R HORIZ. REBAR, TYP. to 11 1 1 1 1 1 U.N.O. a ?� 0'-0 9 "Alternate: i L Jil z The reinf. bars shall be F — — — — — — — — — — — 'L J11 V5 cont. around comer by cold bending the bar w/ min. 04 L 1 I §11a -4— Ci bar lap oi 25". 1 .11 I all Ci CN C? 4'-0" -3 1/2" SLO?j;4 TYP. CORNER BAR DTL. STEPS AS K;ITCEHESLAND REQUIRED PER LOW WALLS I CHASE SCALE: 1 1/2"=V-0" FIELD TO CONDITIONS ISLAND 3-1/2" MIN 1000 PSI CONC. PROVIDE 1 Y2" SLAB FOR HERNANDO RECESSFOR COUNTY ONLY SGD REFER TO 3-1/2" MIN 2500 PSI CONC 9 zo 03 1/2" 1 1 , MASO'N'S SLOPE SLAB OVER 6 MIL BUILDER TO PROVIDE 2 STORY LO FOR WIDTH VISQUEEN VAPOR BARRIER 'D APPLIANCE PROTECTION (2) #5 REBAR WHEN REQUIRED PER FBC VERTICALS w/ in (2) #5'S FILLED CELL TYP @ 2 STORY L PROVIDE Y2" x 9" 2'-6" x Z-16" x 1 '-0' -3 1/2" . *�, RECESS FOR FRT. DOOR T_ A SLOPE, W/ (3) #5'S E.W. A 0'-0" TOP OF CONC.1 PAVER TO BE 4' 1*7� BELOW FIN. FLR. \, �3 U(2) #5'S IL 7 S-1 13-441" ...... IF, 2 N;, UD BF �00� FOR A/C —4. 7 q 2'-6" x Z-6" V-O" x 9 _7 Ci W/ (3) #5'S E.W. __C1 — — — — — — t C14 7� _:�J— 71 5'-4fg- INDICATES FILLED CELL w/ 3000 rj PSI CONC. GROUT FROM FT. To TYP @ 2 STORY BEAM W/ (1) #5 REBAR VERT ABOVE SLAB TYP @ ALL PLACES LO SHOWN HOOKED FTG. DOWELS 5" EMBED W/ 25" EXT. ABOVE SLAB "GRADE 40 STEEL" HVAC CHASE 0101, BASED ON LOCATION 64" 16-21" X A ;0 G V1.1 c,r ............... ............................ ........ ... ... i* M11 1-i n# TYP @ 2 STORY 5'-4" � 2'-21j' 1, 2'- FOUNDATION PLAN. SCALE: Y4"= V-0" (D!� Uj U 0 L.0 V) (2:: 0 in in ce) 0 C) C\l a) CY) CY) C0 a M Cl) E 00 2:2 M 0 8 cq 0 00 cd- 0 x 1, O,q < 0 CL -�, 0 B D. /_2_-, j o' 'Z 1.0 o 13! LUg: - F OW rr. omv)t E S I UM Cc, LU 0 0 ca 1:1 El 1:1 To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code Sth Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature an sea . C) C:) Z r-4 0 a) r-, 1­4 4- C:) V) 15 t�o o > Lf) r') fu In z (n 7 V) 0 (L) — Lr) < U_ Z00 E z LU C:) _j C) W 110 �C) z z 08 0, a .,, . UZ< - a- Lz. 8, g L.0 CL LO co z Z Z 0 Lr) z 0 -0 r,*.% z V) 3: L0 r*4 0 0 U_ z 0 z uj 89 0 x 0 rj 0 Z,2�� LU W Z 3,: CY-1 ILI 0 9 Cc, z z r1j zo " LU _j Lr) T__4 LLI 6j < z Z, 0 R 8 z L) 0 uj Lu z z t < If :D Cy V) Z co 0 z U-1 0 z uj SCALE AS NOTED DATE 2/24/2014 TECH: MIAMES VERSION No' 10 SHEET NO. 6.0 U Cill Cill A/ V/ /I unes'ek Me= UPLIFT CONNECTION CROSS-REFERENCE MARK SIMPSON STRONG TIE USP MANUFACTURING, INC. 0 CONNECTOR CAPACITY FASTENERS CONNECTOR CAPACITY FASTENERS SYP SPF SYP SPF A HETA20 1810 9 - 10d x 1 1/2" HTA20 1615 1585 10 - 10d x 1 1/2" B HETA16 1810 9 - 10d x 1 1/2" HTA16 1615 1585 10 - 10d x 1 1/2" C H2.5A 600 535 10 - 8d RT7A 670 565 10 - 8d X 1 1/2" D H3 455 320 8 - 8d RT3 610 525 8 - 8d X 1 1/2" E META20 1450 7 - 10d x 1 1/2" HTA20-18 1400 1400 10 - 10d X 1 1/2" F HHETA20 2235 10 - 10d x 1 112" G H10A 1340 1015 18 - 10d x 1 1/2" RT16A 1380 116 1 1/2% 8-1 Od H HT74 3610 3105 518"ANCH. 08) 1061-1/2 HTT4 2715 5/8"ANCH. 1(20) 1 0dx1 -1/2 i HTT5 4350 3740 5/8"ANCH. / (26) 10dxl-1/7 HTT5 3225 518" ANCH. 1(28) 1 0dx1 -1 /2 K HD3B* 3130 3050 5/8"DIA. BOLTS TDX2-TZ 2345 — 12 - 5/8- DIA. BOLTS L HD5B* 4505 3785 5/8"ANCH. 3/4" STUD BOLTS TDX6 5320 — 2 - 7/8" DIA. BOLTS M HD7B* 6645 5650 7/8"ANCH. 3/4" STUD BOLTS TDX10 7845 — 4 - 7/8" DIA. BOLTS N LUS26 1165/1070 1005/915 8 - 10d x 3" JUS26 1115/1060** — 8-10d P HUS26 1550/3335 1335/2820 20 - 16d x 3 1/2" HUS26 1925/3295 — (20)16d x 3-1/2" 0 HUS28 2000/4220 1720/3125 30 - 16d x 3 1/2" HUS28 2570/4345 — 30d - 1 6d x 3-1/2" R MTS12 1000 860 14 - 1 Od x 1 1/2" MTW12 1 1195 1005 14-1 Od x 1-1 /2" S MTS16 1000 860 14 - 1 Od x 1 1/2" MTW16 1 1195 1005 1 14-1 Old x 1-1 /2" T MTS20 1000 860 14 - 10d x 1 1/2" MTW20 1 1195 1005 114-1 Od x 1-1 /2" U MGT/MUGT 3140 3140 22 - 1 Od X (1) 5/8" ATR W/ 5" EMBED W1 SIMPSON "S T' EPDXY V LGT2 2150 1850 (16)16d SINKERS & (7) 114" x 2-1/4" TITENS LUGT2 1850 1810 (16)10d NAILS AND (5) 1/4" x 3" WEDGE BOLTS "XI HTS 20 1450 1245 24-1 Od X 1 1/2" HTW20 1530 1285 24-1 Od X 1 1/2" Spi 585 535 10-10d SPT22 1 685 8-10d SP2 1065 605 12-10d SPT24 1030 12-10d HCP2 645 555 12-1 Od X 1 1/2" MINIMUM 3" MEMBER REACTIONS ARE FOR ROOF LOADS ONLY DO NOT DRIVE NAILS THROUGH THE TRUSS PLATE ON THE OPPOSITE SIDE OF THE TRUSS, WHICH COULD FORCE THE PLATE OFF OF THE TRUSS. ALL EPDXY ANCHORS USP CIA-7000C NOTE: DOUBLE FELT REQ'D ON ROOF PITCHES 3/12 & LOWER. LOADS — ROOF = L / 360 FLOOR = L / 480 W/ 3/8" MAX DEFLECTION. FLOOR JOIST SPACING SHALL BE MAX OF 19.2" OC FOR HARDWOOD & TILE AREA'S & 24" OC FOR CARPET ARENS DROP HIP DETAIL. 2-0-0 MAXIUM SPACING ON VERTICALS OF (B) TRUSS (B) EI) OR 2 PLY CARRIER =r 1-8-8 CLEAR GAP BETWEEN (B) TRUSSES (+/- 6-) 'FASTEN EACH B) TRUSS WES TO EACH (A) TRUSS TOP CHORD @ EVERY INTERSECTING POINT SHOWN ON THE HIP TRUSS SYSTEM BELOW. FASTEN TOP CHORDS OF EACH (B) TRUSS TO THE TOP CHORDS OF (A) TRUSSES AT EVERY OTHER INTERSECTING POINT (-). INTERSECTING POINT TO BE FASTENED WITH 2 - 16d COMMON NAILS OR 0.128'x 3" GUN NAILS. FASTEN BOTTOM CHORD OF (B) TRUSS TO TOP CHORD OF CARRIER TRUSS WITH + THE SAME SPECIFIED COMMON NAILS OR GUN NAILS AT 48- OC. (+) IN LIEU OF PREFABRICATED HIP PLANING TRUSSES, (B) 2x4 SO. PINE #2 OR #2 PT. STICK LUMBER (LAID FLAT WISE) MAY BE USED. FOLLOW FASTENING SCHEDULE AS DEFINED FOR HIP PLANING TRUSSES. R1 '15�55 STICK FRAMING SPLICING IS ALLOWED BETWEEN TRUSSES OR AT TRUSS 1 2 PL RIE INTERSECTIONS. SPLICING 2 x NT LDG TO BE STAGGERED BETWEEN COMMON TRUSSES, NO CATS REQUIRED UNDER STICK FRAMING SPLICING. MINIMUM LENGTH OF STICK FRAMING TO BE V-0"ON A HORIZONTAL PROJECTION. NOTE: SEE SHEET D-1 FOR ROOF FRAMING DETAILS 1. (2) 12d TOENAILS EACH SIDE OF FLOOR TRUSS TO WALL OR BEAM BELOW TYP @ INT. BEARING U.N.O. STRUCTURAL SHEATHING (SEE TB13 FOR NAILING INFO.) — 2x CONT. W1 (2)-12d NAILS @ EA. TRUSS- 2x4 CONT. RIBBON W1 (4) 16d NAILS @ EA. TRUSS 2x BLOCKING W/(2) -12d NAILS @ EA. END 8d NAILS @ 24" O.C. TO BLOCKING — 2x STUDS SEE PLAN FOR INFO PLYWOOD 2x6 CONT. W/ (2)-12d NAILS @ EA. TRUSS CANTILEVER FLOOR TRUSS *SEE PLAN T TRUSS BRG. \—CONNECTOR AT EACH TRUSS, SEE PLAN LINTEL SEE PLAN SHEATHING CANT. FLOOR TRUSS CONN-. SCALE: 3/4" = V-0" SCALE: Y4"=1'-O" I (D Ln to CL V) (D Q) U-) 4--J Lu U- 0 LU til- L0 -D 0 U) (n C�) V) 1-- -20 04 WCO LU E 0 0) ce) C M ce) T :2 V) 0 C', U InD a) 0 CO S,6 �� 0_,,_ a) < U5 ac) Lo 0 -q- 5Q) q Ci N C D C pit —ft OD" C14 Ln 0 A N 1A �N < -,L0 CO 'r j —JI.;M LL C'-� 1W 4W Fr U U— U- 0 rkv- mr 9 C. R 04 ....... Z IL Uj N 1141 0 0 El 1:1 To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code Sth Edition (2014) Residential. Engineer's signature and sea] is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. C) Z r-4 0a) r�, 0-4 4-J C:) V) , =5 "o C:) > v) 0 V) fO Lf) z CL V) 5- LI) 0 ai Ln Cv. fu T-11 U z CL OC) E z z § fu C:) —j C:) LULU 0, Z < z Z tj �z C'e ow :5 gso, a -. x ZE E z< co, z uj'" cozo LLI Lr) >Z, Z8 Ln x z � W� 0 -0 N ILL ro Lr) fr 0 > 0 0 U V) ILL LL 0 Z 0 0 0 0 r- 06 b 12 M- 5 X" NON Z�2�- LLJ Z;� < < 3: W Coe z z LU (%4 17�4 Lr) Ili =5 L<) W z T-4 * I Uj 2: 2: < 5? 8'z 0 ��, � F) < z z t W C, < z D Rz 0 z :5 Lu -r � 2 < z rn a- I Ul I SCALE AS NOTED DATE 2/24/2014 TECH: MJAMES VERSION No' 10 SHEET NO. 7.0 ILOCKING IY UPLIFT CONNECTION CROSS-REFERENCE MARK SIMPSON STRONG TIE USP MANUFACTURING, INC. 0 CONNECTOR CAPACITY FASTENERS CONNECTOR CAPACITY FASTENERS SYP SPF SYP SPF A HETA20 1810 9 - 10d x 1 1/2" HTA20 1615 1585 10 - 10d x 1 1/2" B HETA16 1810 9 - 10d x 1 1/2" HTA16 1615 1585 10 - 10d x 1 1/2" C H2.5A 600 535 10 - 8d RT7A 670 565 10 - 8d X 1 1/2" D H3 455 320 8-8d RT3 610 525 8 - 8d X 1 1/2" E META20 1450 7 - 10d x 1 1/2" 1400 1400 110 - 10d X 1 1/2" F HHETA20 2235 10 - 10d x 1 1/2" -HTA20-18 1 G H10A 1340 1015 18 - 10d x 1 1/2" RT16A 1380 1160 19-1 Old X 1 1/2-& 8-1 Od H HTT4 3610 3105 5/8"ANCH./(18) 10dx1-1Q HTT4 2715 5/8" ANCH. /(20) 10dxl-1/2 i HTT5 1 4350 — 3740 5/8" ANCH. / (26) 10dxl-1/2" HTTS 3225 5/8' ANCH, 1( 8) 1 Odxl-1/2 K HD3B - 1 3130 3050 5/8" DIA. BOLTS TDX2-TZ 2345 — 2 - 5/8" DIA. BOLTS L HD58 * 4505 5/8"ANCH. 3/4" STUD BOLTS TDX6 5320 — 2 - 7/8" DIA. BOLTS M HD713 * 6645 5650 718"ANCH. 3W1 STUD BOLTS TDX10 7845 — 4 - 7/8" DIA. BOLTS N LUS26 1165/1070 1005/915 8 - 10d x 3�' JUS26 1115/1060** — 8 - 10d P HUS26 1550/3335 1335/2820 20 - 16d x 3 1/2" HUS26 1925/3295 — (20)16d x 3-1/2" Q HUS28 2000/4220 1720/3125 30 - 16d x 3 1/2" HUS28 2570/4345 — 30d -1 6d x 3-1/2" R MTS12 1000 860 14 - 10d x 1 1/2" MTW12 1195 1005 14-10d x 1-1/2" S MTS16 1000 860 14 - 10d x 1 1/2" MTW16 1195 1005 14-10d x 1-1/2" T MTS20 1000 860 14 - 10d x 1 1/211 MTW20 1 1195 1005 14-10d x 1-1/2" U MGT/MUGT 3140 3140 22 - 10d X (1) 5/8" ATR W/ 5" EMBED W/ SIMPSON "SE-r- EPDXY V LGT2 2150 1850 (16)16d SINKERS & (7) 1/4"x 2-1/4" TITENS LUGT2 1850 1810 (16)10d NAILS AND (5) 1/4" x 3" EDGE BOLTS 'Ir HTS 20 1450 1245 24-1 Od X 1 1/2" HTW20 1530 1285 24- 1 Od X 1 1/2" Spi 585 535 10 - 10d SPT22 685 8 - 10d SP2 1065 605 12 - 10d SPT24 1030 12 - 10d HCP2 645 555 12-1 Od X 1 1 /2' MINIMUM 3" MEMBER REACTIONS ARE FOR ROOF LOADS ONLY DO NOT DRIVE NAILS THROUGH THE TRUSS PLATE ON THE OPPOSITE SIDE OF THE TRUSS, WHICH COULD FORCE THE PLATE OFF OF THE TRUSS. ALL EPDXY ANCHORS USP CIA-7000C NOTE: DOUBLE FELT RECI'D ON ROOF PITCHES 3/12 & LOWER. LOADS -- ROOF = L / 360 FLOOR = L / 480 W1 3/8" MAX DEFLECTION. FLOOR JOIST SPACING SHALL BE MAX OF 19.2"OC FOR HARDWOOD & TILE ARENS & 24" OC FOR CARPET ARENS DROP HIP DETAIL. 2-0-0 MAXIUM SPACING ON VERTICALS OF (B) TRUSS + 7/ IA I I I I X\ (B) B) (A) -IJ (+ %\—I OR 2 PLY CARRIER 1-8-8 CLEAR GAP BETWEEN (B) TRUSSES 6") 'FASTEN EACH (B) TRUSS WEB TO EACH (A) TRUSS TOP CHORD @ EVERY INTERSECTING POINT SHOWN ON THE HIP TRUSS SYSTEM BELOW. FASTEN TOP CHORDS OF EACH (B) TRUSS TO THE TOP CHORDS OF (A) TRUSSES AT EVERY OTHER INTERSECTING POINT (--). (B INTERSECTING POINT TO BE FASTENED WITH 2 - 16d COMMON NAILS OR 0.128"x 3"GUN NAILS. FASTEN BOTTOM CHORD OF (B) TRUSS TO TOP CHORD OF CARRIER TRUSS WITH H— THE SAME SPECIFIED COMMON NAILS OR GUN NAILS AT 48"OC. (+) IN LIEU OF PREFABRICATED HIP PLANING TRUSSES, (B) 2X4 SO. PINE #2 OR #2 PT, STICK LUMBER (LAID FLAT WISE) MAY BE USED. FOLLOW FASTENING SCHEDULE As DEFINED <j1 FOR HIP PLANING TRUSSES. RI STICK FRAMING SPLICING IS ALLOWED BETWEEN TRUSSES OR AT TRUSS "i ,OR 2 '1111E INTERSECTIONS. SPLICING / 2 x croVY'LNMER TO BE STAGGERED BETWEEN COMMON TRUSSES, NO CATS REQUIRED UNDER STICK FRAMING SPLICING. MINIMUM LENGTH OF STICK FRAMING TO BE T-0"ON A HORIZONTAL PROJECTION. NOTE: SEE SHEET D-1 FOR ROOF FRAMING DETAILS 1. (2) 12d TOENAILS EACH SIDE OF FLOOR TRUSS TO WALL OR BEAM BELOW TYP @ INT. BEARING U.N.O. ji� 11 I : Will I WAK SCALE: Y4"=1'-0" 0�2 Z CY) Z V) 0 (1) C-/) U 0 V) - �12 E 0 W c') 8 0 04 (D 'M Lij E lain 0) Cl) c: C0 2 q 0= C\I 2 W C) W a) o LL 00 -:5 - GO 0 CU --.4 iz�l 43) -)d 0 U) 0- 0 U') 0 .;r V CL 6<6 A I N-C B D C al'o, 00 Cn d N LL-. LU L,-c M- , �rk r V 0 Z 9-- I � I., I - S Us -,v LU A 0 x To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Co de 5th Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. Z r,4 0 CUN 4-j C:) , 5 -0 > o p 4-J < U-) (0 Ln Z C1- 2: (Al a) In L- LL CL U CL OC) Z Z 3i E Z Uj C:) —j C:) W 0 ,-Z E0 ZE Z 08 0, 50. U Z Z LZL, Z" 0 0 Ln u- 0 li-� Zco z u" >Z, L0 rr 2: Z z Z 0 -0 N LL fu Lr) Cr 0 0 0 U LL Uzi LU M 1.4 LL- 0 r- P, 0Z < 06 0 0-" co 2t r%% 8 2� 1Z < u, Z Z uj,3 LL. 2 - �: LLj Ln Uj < Lij < Z , 0 Z 9 =) 8 0 W!J � 14 :C g�98 ro Z < < U) (n z 0 Z LU -2 < U) z SCALE AS NOTED DATE 2/24/2014 TECH: MIAMES VERSION No' 10 SHEET NO. 7.1 Z :9 & GENERAL INSTALLATION NOTES 1 . Provide full mortar head and bed joints. 2. Shore filled lintels as required. 3. Installation of lintel must comply with the architectural and/or structural drawings. 4. LI-Lintels are manufactured with 5-1/2" long notches at the ends to accommodate vertical cell reinforcing and grouting. 5. All lintels meet or exceed U360 vertical deflection, except lintels 17'-4" and longer with a nominal height of 8" meet or exceed LA 80. 6. Bottom field added rebar to be located at the bottom of the lintel cavity. 7. 7/32" diameter wire stirrups are welded to the bottom steel for mechanical anchorage. 8. Cast -in -place concrete may be provided in composite lintel in lieu of concrete masonry units. 9. Safe load ratings based on rational design analysis per ACI 318 and ACI 530 10. Product Approvals: Miami Dade County, Florida Nos.03-0605.05 and 03-0605.04. 11. The exterior surface of lintels installed in exterior concrete masonry walls shall have a coating of stucco applied in accordance with ASTM C-926 or other approved coating. 12. Lintels loaded simultaneously with veritcal (gravity and uplift) and horizontal (lateral) loads should be checked for combine loading with the following equation: Applied vertical load + Applied horizontal load Safe vertical 16-a—d Safe horizontal load <1 .0 GENERAL CONCRETE LINTEL SCHEDULE APPROVED LINTEL MANUFACTURERS: CASTE-CRETE, QUALITY I M 0 E a 8F441B/lT8F401B/lT8RF40OB/lT8F321B/lT OW Ell 1 r-r— F = FILLED WITH EBAR IN. AT TOP 1) REQ'D ALTERNATE POWERS GROUT 1 U = UNFILLED 4 R RECESSED ICLEAR STEEL LINTEL QTY. OF #5 A F —RETA SEL BCOATVTI 4 0 F L I N7T TOYM F- 4 M.U. #5 REBAR AT TOP MIN. (1) RECI'D_ 1-1/2"CLEAR F- -i 8F16- B/1 T 0 *\\,--C.M.U. tNOMINAL. t Z —GROUT a-, QUANTITY OF #5 REBAR AT 4 L_All� -4t5 REBAR AT BOTTOM OF SO i- I 120 ull WIDTH TOP 0 0 0-* LINTEL CAVITY LLl - 6 to 00�— NOMINAL- -BOTTOM um, - 00 Z� HEIGHT REINFORCING < d 7-5/8"ACTUAL � PROVIDED IN X 7� LU u) > 8- NOMINAL WIDTH " LINTEL 3: g t; 3*5 UM, , #5 REBAR AT BOTTC AS INDICATED (VARIES) ao ii a MATERIALS 77Fc_p_r_e_cai = 3500 psi. 2. fc prestressed lintels = 6000 psi. 3. grouted per ASTM C476 fg = 3000 psi w/ 4. maximum 3/8" aggregate and 8" to 1 V slump. 5. Concrete masonry units (CMU) per ASTM C90 w/ minimum net area compressive strength = 1900 psi. 6. Reber per ASTM A615 Grade 60. Prestressing strand per ASTM A416 grade 7. 270 low relaxation. 7132 wire per ASTM A51 0. 8. Mortar per ASTM C270 type M or S. L:NTEL MINIMUM DEPTHS ARE CALLED OUT ON LINTEL PLAN. IF CONTRACTOR INSTALLS A DEEPER L NTEL THAN INDICATED ON THE PLAN, DOING THIS INCREASES THE STRENGTH OF THE LINTEL AND IS APPROVED WITHOUT ENGINEERING LETTER. IF A SMALLER LINTEL IS INSTALLED CONTACT E.O.R. FOR APPROVAL. (SEE LINTEL PLAN FOR SCHEDULE) 2x8 #2 SYP STUDS @ 8" O.C. W/ (2) USP MSTAM36 STRAPS EACH STUD ((1) STRAPS EACH SIDE) CENTERED W/ (13) 10d NAILS & (8) Y4" TITENS OR (2) 2x8 #2 SYP STUDS @ 16" O.C. W/ (4) USP MSTAM36 STRAPS ((2) STRAPS EACH SIDE) 2x8 #2 SYP P.T. BASE PLATE W/ Y2" EPDXY ANCHOR OR Y2" J BOLT W/ MIN. 7" EMBEDMENT @ 32" O.C. & 6" FROM EACH END 16 GAUGE POWERS STEEL BOXED LINTEL POWERS STEEL BOXED LINTEL NOTES (ALT.) ONLY IF NOTED ON LINTEL PLAN 1. Refer to manufacturer's specifications for installation. 2. Contractor to provide proper protection of lintel to prevent rusting. Refer to manufacturer's specifications. 3. If lintel Is scratched or damaged refer to Powers Steel for repair. 4. Lintel depth to match precast depth. One #5 Bar required at top see lintel planidetails for bottom steel required. 5. A bonding agent must be applied to the Steel Box lintels prior to applying the cementitluos coating. See contractor specifications STRUCTURAL SHEATHING ATTACHED PER NAILING SCHEDULE OL SEE PLAN 'F T/WALL -[1---8" KNOCKOUT COURSE W/ (1) #5 CONT. SEE PLAN FOR FILLED CELL SPACING WALL SPLICE DETAIL SCALE: 1" = V-0" 6-8" LL LINTEL PLAN� SCALE: Y4"= V-0" I 0 tp (D a_ V) 0 Q) C—/) 4--J UJ U 0 UJ 011 V) 0 0 U171 U C\1 WCO UJ NEEk E 0 ce) cl) 0 C\J q 3Z a) U VW) 0 r- 00 S �� 0 r- CLI < U) CL 0 ur) OT CL A I 11 C, D, C B D. q) c� Z Z ce) IRE M'i 11A.r W cLL , A& LU Z A _Yo010 LL R.49 0 '. , �1,, W 'A Z, " tl #111flipp _J V . d (D 0 0 El 0 To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code 5th Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. Z 0a) r- �--4 4-J (=) U0 1 53 t 0 c) > U) C:) U-) Z L11 N 5- a) Ln < L I U_ C)L V7<7 � iy- U CL OC) Z Z < E Z Lu C:) _J C:) W tD 0 0 Lu Z Z U 0 EZ 2 W L) LM !E M Z Z 0 L4 Z 2 Z L-L 00� 2 8 Z 0 (LNU Z 0 >< U Lr) Z Z 0 -0 N 3t D Lr) Z > 0 U _J LU < U1 0 OZ 0 Z ra Z 1Z, cl� N < UJ e 0 Z Z Lij N ul Lij 6i 2: =0 0 Z 8 E2 < < < Z < LU Z cn Z Z t 24, V) Z 0 0 Z LU r-) 7­4 CL Ul) SCALE AS NOTED DATE 2/24/2014 TECH: MJAMES VERSION No' 10 SHEEIF NO. 8.0 N I NOTE: BORATE APPLIED TO ALL FRAME MEMBERS WITHIN 24" A.F.F. 1) METHOD OF TREATMENT SHALL BE APPROVED BY THE GOVERNING JURISDICTION "LIQUID BORATE OR BOR-A-CCIR" PRODUCT METHODS MUST BE DETERMINED AT PERMIT STAGE. 2) PRESSURE TREATED LUMBER THAT HAS BEEN CUT OR DRILLED THAT EXPOSES UNTREATED PORTIONS OF WOOD ARE REQUIRED TO BE FIELD TREATED TO PREVENT INSECT INFESTATION. ATTENTION: CHEMICAL CHANGES IN PRESSURE TREATED WOODS AS OF DECEMBER 31ST, 2003, CHROMATED COPPER ARSENATE (CCA-C) WILL NO LONGER BE PRODUCED FOR RESIDENTIAL OR GENERAL CONSUMER USE. SEVERAL NEW PRESSURE TREATED WOOD ALTERNATIVES HAVE BEEN CREATED TO REPLACE CCA-C. MANY OF THE NEW PRESSURE TREATED WOODS USE CHEMICALS THAT ARE CORROSIVE TO STEEL. IT IS THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THE TYPE OF WOOD TREATMENT AND TO SELECT APPROPRIATE CONNECTORS THAT RESIST CORROSION. FOR EXAMPLE, ACQ-C, ACQ-D, CBA-A, OR CA-B REQUIRE HOT -DIPPED GALVANIZED OR STAINLESS STEEL FASTENERS. DOT SODIUM BORATE (SBX) DOES NOT. REQUIRED SAFETY GLAZING IN HAZARDOUS LOCATIONS (RE: FRC R308.4) R308.3 HUMAN IMPACT LOADS. INDIVIDUAL GLAZED AREAS INCLUDING GLASS MIRRORS IN HAZARDOUS LOCATIONS SUCH AS THOSE INDICATED AS DEFINED IN SECTION R308.4 SHALL PASS THE TEST REQUIREMENTS OF CPSC 16 CFR, PART 1201 CRITERIA FOR CATEGORY I OR CATEGORY 11 AS INDICATED IN TABLE R308.3 EXCEPTIONS: 1. POLISHED WIRED GLASS FOR USE IN FIRE DOORS AND OTHER FIRE RESISTANT LOCATIONS SHALL COMPANY WITH ANSI Z971 2. LOUVERED WINDOWS AND JALOUSIES SHALL COMPANY WITH SECTION R308.2 R308.4 HAZARDOUS LOCATIONS, THE FOLLOWING SHALL BE CONSIDERED SPECIFIC HAZARDOUS LOCATIONS FOR THE PURPOSE OF GLAZING: 1. GLAZING IN SWINGING DOORS EXCEPT JALCUSIES. 2. GLAZING IN FIXED AND SLIDING PANELS OF SLIDING DOOR ASSEMBLIES AND PANELS IN SLIDING AND BIFOLD CLOSET DOOR ASSEMBLIES. 3. GLAZING IN STORM DOORS. 4. GLAZING IN ALL UNFRAMED SWINGING DOORS. 5. GLAZING IN DOORS AND ENCLOSURES FOR HOT TUBS, WHIRLPOOLS, SAUNAS, STEAM ROOMS, BATHTUBS, AND SHOWERS. GLAZING IN ANY PART OF A BUILDING WALL ENCLOSING THESE COMPARTMENTS WHERE THE BOTTOM EXPOSED EDGE OF THE GLAZING IS LESS THAN 60 INCHES (1 524MM) MEASURED VERTICALLY ABOVE ANY STANDING OR WALKING SURFACE. 6. GLAZING, IN AN INDIVIDUAL FIXED OR OPERABLE PANEL ADJACENT TO A DOOR WHERE THE NEAREST VERTICAL EDGE IS WITHIN A 24-INCH(610MM) ARC OF THE DOOR IN A CLOSED POSITION AND WHOSE BOTTOM EDGE IS LESS THAN 60 INCHES (1524MM) ABOVE THE FLOOR OR WALKING SURFACE. 7. GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL, OTHER THAN THOSE LOCATIONS DESCRIBED IN ITEMS 5 AND 6 ABOVE, THAT MEETS ALL OF THE FOLLOWING CONDITIONS: 7.1 EXPOSED AREA OF AN INDIVIDUAL PANE GREATER THAN 9 SQUARE FEET (0.836 M2). 7.2 BOTTOM EDGE LESS THAN 18 INCHES (457 MM) ABOVE THE FLOOR, 7.3 TOP EDGE GREATER THAN 36 INCHES (914 MM) ABOVE THE FLOOR. 7.4 ONE OR MORE WALKING SURFACES WITHIN 36 INCHES (914 MM) HORIZONTALLY OF THE GLAZING. 8. ALL GLAZING IN RAILINGS REGARDLESS OF AN AREA OR HEIGHT ABOVE WALKING SURFACE. INCLUDED ARE STRUCTURAL BALUSTER PANELS AND NONSTRUCTURAL IN FILL -PANELS. 9. GLAZING IN WALLS AND FENCES ENCLOSING INDOOR AND OUTDOOR SWIMMING POOLS, HOT TUBS AND SPAS WHERE THE BOTTOM EDGE OF THE GLAZING IS LESS THAN 60 INCHES (1524 MM) ABOVE A WALKING SURFACE AND WITHIN 60 INCHES (1524 MM) HORIZONTALLY OF THE WATER'S EDGE. THIS SHALL APPLY TO SINGLE GLAZING AND ALL PANES IN MULTIPLE GLAZING. 10. GLAZING ADJACENT TO STAIRWAYS, LANDINGS, AND RAMPS WITHIN 36 INCHES (914 MM) HORIZONTALLY OF A WALKING SURFACE WHEN THE EXPOSED SURFACE OF THE GLASS IS LESS THAN 60 INCHES (1524 MM) ABOVE THE PLANE OF THE ADJACENT WALKING SURFACE. 11. GLAZING ADJACENT TO STAIRWAYS WITHIN 60 INCHES (1524 MM) HORIZONTALLY OF THE BOTTOM TREAD OF A STAIRWAY IN ANY DIRECTION WHEN THE EXPOSED SURFACE OF THE GLASS IS LESS THAN 60 INCHES (1524 MM) ABOVE THE NOSE OF THE TREAD. EXCEPTION: THE FOLLOWING PRODUCTS, MATERIALS AND USES ARE EXEMPT FROM THE ABOVE HAZARDOUS LOCATIONS: 1. OPENINGS IN DOORS THROUGH WHICH A 3-INCH(76 MM) SPHERE IS UNABLE TO PASS. 2. DECORATIVE GLASS IN ITEMS 1, 6 OR 7. 3. GLAZING IN SECTION R308.4, ITEM 6, WHEN THERE IS AN INTERVENING WALL OR OTHER PERMANENT BARRIER BETWEEN THE DOOR AND THE GLAZING. 4. GLAZING IN SECTION R 308.4, ITEM 6, IN WALLS PERPENDICULAR TO THE PLANE OF THE DOOR IN A CLOSED POSITION OR WHERE ACCESS THROUGH THE DOOR IS TO A CLOSET OR STORAGE AREA 3 FEET (914 MM) OR LESS IN DEPTH. GLAZING IN THESE APPLICATIONS SHALL COMPANY WITH SECTION R308.4, ITEM 7. 5. GLAZING IN SECTION R308.4, ITEMS 7 AND 10, WHEN A PROTECTIVE BAR IS INSTALLED ON THESE ACCESSIBLE SIDE(S) OF THE GLAZING 36 INCHES 12 INCHES (914 1 MM 51 IMM) ABOVE THE FLOOR. THE BAR SHALL BE CAPABLE OF WITHSTANDING A HORIZONTAL LOAD OF 50 POUNDS PER LINEAR FOOT KG/M) WITHOUT CONTACTING THE GLASS AND BE A MINIMUM OF 1 Y2 INCHES (38 MM) IN HEIGHT. 6. OUTBOARD PANES IN INSULATING GLASS UNITS AND OTHER MULTIPLE GLAZED PANELS IN SECTION R308.4, ITEM 7, WHEN THE BOTTOM EDGE OF THE GLASS IS 25 FEET (7620 MM) OR MORE ABOVE GRADE, A ROOF, WALKING SURFACES, OR OTHER HORIZONTAL (WITHIN 45 DEGREES (0.79 RAD) OF HORIZONTAL] SURFACE ADJACENT TO THE GLASS EXTERIOR. 7. LOUVERED WINDOWS AND JALOUSIES COMPLYING WITH THE REQUIREMENTS OF SECTION R308.2. 8. MIRRORS AND OTHER GLASS PANELS MOUNTED OR HUNG ON A SURFACE THAT PROVIDES A CONTINUOUS BACKING SUPPORT. 9. SAFETY GLAZING IN SECTION R308.4, ITEMS 10 AND 11 IS NOT REQUIRED WHERE: 9.1 THE SIDE OF STAIRWAY, LANDING OR RAMP HAS A GUARDRAIL OR HANDRAIL, INCLUDING BALUSTERS OR IN -FILL PANELS, COMPLYING WITH THE PREVISIONS OF SECTION 1012 AND 1607.7 OF THE FLORIDA BUILDING CODE, BUILDING; AND 9.2 THE PLANE OF THE GLASS IS GREATER THEN 18 INCHES (457 MM) FROM THE RAILING. 1. SPECIFICATIONS CONSTRUCTION: 1. 1. 1. ACI 318-11 BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE 1.1.2. ACI 530-11, ASCE 5/TMS 402-11 & ACI 530.1-11, ASCE 61TMS 602-11 SPECIFICATIONS FOR MASONRY STRUCTURES. 1.1.3. ASTM C270-07a, C90-06b & C91-05 SPECIFICATIONS FOR MASONRY STRUCTURES 1.1.4. NATIONAL DESIGN SPECIFICATIONS (NDS) FOR WOOD CONSTRUCTION, 2012 EDITION, AND ALL ACCOMPANYING SUPPLEMENTS. 1.1.5. FLORIDA RESIDENTIAL CODE (FRC), FLORIDA BUILDING CODE (FBC) 5th ad. (2014) 1.1.6. "MANUAL OF STEEL CONSTRUCTION, ALLOWABLE STRESS DESIGN', BY THE AMERICAN INSTITUTE OF STEEL CONSTRUCTION, (AISC) 13TH EDITION. 1.1.7. "DESIGN SPECIFICATION FOR LIGHT METAL PLATE CONNECTED WOOD TRUSSES" BY THE TRUSS PLATE INSTITUTE TR11-02. 1.2. DESIGN: 1.2.1. ACI 301-11 BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE 1.2.2. ACI 530-11, ASCE 5rrMS 402-11 & ACI 530.1 -11, ASCE 61TMS 602-11 SPECIFICATIONS FOR MASONRY STRUCTURES. 1.2.3. ASTM C270-07a, C90-06b & C91-05 SPECIFICATIONS FOR MASONRY STRUCTURES 1.2.4. NATIONAL DESIGN SPECIFICATIONS (NDS) FOR WOOD CONSTRUCTION, 2012 EDITION, AND ALL ACCOMPANYING SUPPLEMENTS. 1.2.5. PLYWOOD DESIGN SPECIFICATIONS (APA) 1.2.6. FLORIDA BUILDING CODE (FBC) 5th ad, (2014) AND FLORIDA BUILDING CODE 5th ad. RESIDENTIAL (FBCR) 1.3. SHOP DRAWINGS: 1.3.1. THERE SHALL NOT BE ANY DEVIATIONS FROM THESE DESIGN PLANS BY OTHERS DURING THE PREPARATION OF SHOP DRAWINGS WITHOUT WRITTEN APPROVAL FROM THE ENGINEER OF RECORD. t 3.2. ALL SHOP DRAWINGS ARE TO BE SUBMITTED TO THE ENGINEER OF RECORD PRIOR TO THE COMMENCEMENT OF CONSTRUCTION. 1.3.3. ALL ROOF AND FLOOR TRUSS SHOP DRAWINGS ARE TO BE SIGNED AND SEALED BY A FLA. REG. PE. AND SHALL INCLUDE: DRAWINGS AND CALCULATIONS, REACTIONS AND BEARING POINTS, BRACING REQUIREMENTS, AND CONNECTIONS TO SUPPORTING TRUSS MEMBERS. 2. DESIGN LOADS 2.1. DEAD LOADS: 2.1.1. UNIT WEIGHT OF SOIL, COMPACTED: 120 PCF 2.1.2. UNIT WEIGHT OF REINFORCED CONCRETE: 150 PCF 2.1.3. UNIT WEIGHT OF 8" C.M.U. BLOCK: 55 PSF 2.1.4. 1 ST FLOOR SUPERIMPOSED LOAD: 20 PSF 2.1.5. UNIT WEIGHT OF 2x4 PARTITION WALLS: 11 PSF 2.1.6. UNIT WEIGHT OF 2x6 BEARING WALLS: 12 PSF 2.1.7. BALCONIES & DECKS: 15 PSF 2.1.8. TILE ROOF TOPCHORD: 15 PSF BOTTOM CHORD: 10 PSF 2.1.9. SHINGLE ROOF TOPCHORD: 7 PSF BOTTOM CHORD: 1OPSF 2.1.10. FLOOR TRUSSES 15 2.2. LIVE LOADS: 2.2.1. SIDEWALK AND DRIVEWAY LOAD: 250 PSF 2.2.2. GARAGELOADS: 40 PSF 2.2.3. PARTITIONED ROOMS: 40 PSF 2.2.4. BALCONY AND DECKS: 60 PSF-UNDER 100 sq. ft. 2.2.5. STAIRWAYS AND LANDINGS: 40 PSF 2.2.6. SLEEPING ROOMS: 30 PSF 2.2.7. FLOOR TRUSS TOP CHORD MINIMUM: 40 PSF 2.2.8. ROOFTRUSS TOP CHORD MINIMUM: 20 PSF BOTTOM CHORD (ATTIC W/O LIMITED STORAGE): 10 PSF (NON -CONCURRENT) BOTTOM CHORD (A -MC W/ LIMITED STORAGE): 20 PSF 2.3. RAILING LOADS: 2.3.1. ALL RAILING AND GUARD RAIL SYSTEM'S ARE TO BE DESIGNED TO WITHSTAND A CONCENTRATED LOAD OF 200 POUNDS APPLIED AT ANY POINT AND IN ANY DIRECTION ON THE RAILING. 2.3.2. ALL RAILING AND GUARD RAIL SYSTEM'S ARE TO BE DESIGNED TO WITHSTAND A HORIZONTAL LOAD OF 50 PLF ON THE GUARDRAIL AND A SIMULTANEOUS LOAD OF 100 PLF APPLIED VERTICALLY DOWNWARD AT THE TOP OF THE GUARDRAIL 2.3.3. GUARDRAIL SYSTEM SHALL BE DESIGNED TO WITHSTAND 2001b CONCENTRATED HORIZONTAL LOAD APPLIED ON 1 SQ. FT. AT ANY POINT IN THE SYSTEM. 2.3.4. 2.3.1., 2.3.2 & 2.3.3. ARE NOT REQUIRED TO BE APPLIED SIMULTANEOUSLY, BUT EACH SHALL BE APPLIED TO PRODUCE THE MAXIMUM STRESSES IN THE MEMBER COMPONENTS. 2.4. WIND LOADS: 2.4.1. WIND DESIGN TO BE CONDUCTED IN ACCORDANCE WITH SECT. R301.2 OF THE FBC 5th ad. (2014), AND CONDUCTED BASED ON A140 MPH 3 SECOND GUST, EXPOSURE "C", IMPORTANCE FACTOR "I"= 1.0. ENCLOSED BUILDING 2.4.2. NET UPLIFT DEAD LOADS - 10 PSF SHINGLE, 15 PSF TILE 2.4.3. WIND LOAD DETERMINATION BASED ON ASCE 7-10 2.5. DEFLECTIONS: 2.6.1. FLOOR TRUSSES SHALL LIMIT DEFLECTION TO U480TIMES THE SPAN FOR LIVE LOADS AND U240 TIMES THE SPAN FOR TOTAL LOAD. 3. DESIGN METHOD 3.1. LOAD FACTOR DESIGN: 3.1.1. THE LOAD FACTOR DESIGN METHOD WAS USED TO DESIGN: CAST -IN -PLACE CONCRETE SLABS AND FOOTINGS 3.2. SERVICE LOAD DESIGN: 3.2.1. THE SERVICE LOAD DESIGN METHOD WAS USED TO DESIGN: MASONRY WALLS AND LINTELS INTERIOR AND EXTERIOR WOOD FRAMING AND SHEATHING STAIRS AND FLOOR FRAMING ROOF FRAMING, SHEATHING AND UPLIFT 3.3. LOAD COMBINATIONS FOR LRFD DESIGNS: 3.3.1. THE FOLLOWING LOAD COMBINATIONS WERE DESIGNED FOR: TOTAL DL + FLOOR LL + ROOF LL TOTAL DIL + FLOOR LL + WIL TOTAL DL + WIL 3.3.2. ALL ROOF AND FLOOR TRUSSES SHALL BE DESIGNED TO RESIST THE WORST LOAD COMBINATION RESULTING IN THE MAXIMUM STRESSES PLACED ON THAT COMPONENT. BOTH PARTIAL, FULL, AND ALTERNATING SPAN LOADING ARE TO BE CONSIDERED. 3.4. DESIGN ASSUMPTIONS: 3.4.1. ALL FOUNDATIONS ARE CENTERED UNDER SUPPORTED COLUMNS AND WALLS UNLESS SHOWN OTHERWISE IN THE DESIGN PLANS. 4. MATERIALS 4.1. REINFORCING STEEL: 4.1.1. REINFORCING STEEL SHALL BE ASTM A615 / Al 85M-04A MIN. GRADE 40, fy = 40 Ksi 4.1.2, LAP SPLICE SHALL BE AS FOLLOWS: #5 BAR 25", #4 BAR 20", #3 BAR 20". 4.1.3. ALL DIMENSIONS PERTAINING TO THE LOCATION OF REINFORCING ARE TO THE CENTERLINE OF EACH BAR EXCEPT WHERE THE COVER DIMENSION IS SHOWN TO THE FACE OF THE CONCRETE. 4.1.4. REINFORCING DETAIL DIMENSIONS ARE OUT TO OUT OF BARS. 4.1.5. REINFORCING MECHANICAL COUPLERS ARE TO DEVELOP 125 % OF THE REQUIRED YIELD STRENGTH OF THE BAR AND ARE TO BE APPROVED BY THE ENGINEER OF RECORD. 4.1.6. DESIGN COVER REQUIREMENTS: C-I-P CONCRETE FORMED AGAINST EARTH: 3" C-I-P CONCRETE EXPOSED TO EXTERIOR: 2" C-I-P CONCRETE NOT EXPOSED )/2. GROUT FILLED MASONRY: y4" 4.1.7. WELDED WIRE FABRIC (WWF): ASTMA-185/Al85M-07 4.1.8. DETAIL REINFORCEMENT IN ACCORDANCE WITH ACI 318-11 (STRUCTURAL CONCRETE) ACI 530-11 (MASONRY STRUCTURES) 4.2. CONCRETE: 4.2.1. CONCRETE TYPE MIN. 28 DAY DESIGN (fc) MODULES OF ELASTICITY DESIGN (E) C-1-P CONCRETE (NORMAL WEIGHT) 2,500 Psi 2,850 Ksi C-1-P CONCRETE (NORMAL WEIGHT) HERNANDO CO. ONLY 3,000 Psi 3,122 Ks! C-1-P GROUT 3,000 Psi 3,122 Ksi 4,2.2. CONCRETE SHALL CONSIST OF 1"MAXIMUM AGGREGATE CONCRETE MIX WITH SLUMP BETWEEN 6" AND 7" AT TIME OF PLACEMENT. SEE SPECIFICATIONS FOR ADDITIONAL CRITERIA. 4.2.3. GROUT SHALL CONSIST OF PEA ROCK (3/8' MAXIMUM AGGREGATE) CONCRETE MIX WITH SLUMP BETWEEN IT'AND 10" AT TIME OF PLACEMENT. SEE SPECIFICATIONS FOR ADDITIONAL CRITERIA. 4.2.4. CONSTRUCTION JOINTS WILL BE PERMITTED 4.2.5. METHOD OF CONCRETE FORMING, PLACEMENT AND CURING $HALL BE CONDUCTED IN ACCORDANCE WITH THE SPECIFICATIONS AS STATED. 4.2.6. EARTH SUPPORTED SLABS (EXCLUDING EXTERIOR WALKWAYS & DRIVEWAYS): 3 1/2"MIN. THICKNESS W/ MIN. REINFORCEMENT OF 6.0 x 6,0 W1 1.4 x 1.4 WWF @ MID -DEPTH OF SLAB. FIBER MESH PER DESIGN MIX MAY BE USED I.L.O. WWF @ CONTRACTORS DISCRETION. 4.2.7. CONCRETE PLACEMENT PRACTICES SHALL BE IN ACCORDANCE W/ ALL ACI- MCP 2011 STANDARDS. 4.3. CONCRETE MASONRY: 4.3.1. FILLED CELLS W/ (1) #5 BAR SHALL BE LOCATED PER PLAN. 4.3.2. LOAD BEARING CONCRETE MASONRY BLOCK SHALL BE ASTM C90-0601, TYPE 11 NON -MOISTURE CONTROLLED. 4.3.3. ALL CELLS & CAVITIES BELOW GRADE WILL BE FILLED W/ CONCRETE IN ALL STEM WALLS. 4.3.4. THE AGGREGATE STRENGTH OF THE BLOCK AND MORTAR SHALL BE F'm = 1,500 PSI MINIMUM. 4.3.5. METHOD OF CONCRETE MASONRY PLACEMENT AND CONSTRUCTION SHALL BE CONDUCTED IN ACCORDANCE WITH THE SPECIFICATIONS AS STATED. 4.3.6. MORTAR SHALL BE ASTM C270 TYPE "S" FOR ALL MASONRY CONSTRUCTION. 4.4. STRUCTURAL LUMBER: 4.4.1.1. INTERIOR LOAD BEARINGWALLS SPF #2, fb = 1,312 PSI, E = 1,400 KSI ALL EXTERIOR FRAMING SPF #2, fb = 1,312 PSI, E = 1,400 KSI 4.4.1.2. ALL FRAME WALLS TO BE CONSTRUCTED USING SPF #2, STUD QUALITY OR BETTER 4,4.2. ALL PLYWOOD USED FOR EXTERIOR APPLICATIONS SHALL BE APA RATED STRUCTURAL SHEATHING 15/32" EXP 1 OR 7/16" STRUCTURAL 1, U.N.O. 4.4.3. ALL PLYWOOD USED FOR INTERIOR APPLICATIONS SUCH AS SUB FLOORING AND SHEAR WALLS SHALL BE APA RATED SHEATHING EXP 1 U.N.O. 4.4.4. IF OSB BOARD IS TO BE USED IN PLACE OF PLYWOOD IS TO HAVE SIMILAR OR GREATER SECTION PROPERTIES. 4.4.5. ONLY STRUCTURAL LUMBER TO BE USED FOR AN EXTERIOR APPLICATION. WOOD IN CONTACT WITH CONCRETE IS TO RECEIVE A STANDARD GRADE PRESSURE TREATING. 4.4.6, WHEN PRE ENGINEERED TRUSSES ARE CALLED FOR ON THE PLANS THE MANUFACTURER IS TO SUBMIT SHOP DRAWINGS TO THE ENGINEER OF RECORD. 4.4.7. DESIGN, FABRICATE AND ERECT WOOD TRUSSES IN ACCORDANCE WITH THE "DESIGN SPECIFICATION FOR LIGHT METAL PLATE CONNECTED WOOD TRUSSES" BY THE ANSI/TPI 1-2007, BCSI 4.4.8. UNTREATED WOOD SHALL NOT BE IN DIRECT CONTACT WITH CONCRETE. SEAT PLATES SHALL BE PROVIDED AT BEARING LOCATIONS WITHOUT WOODEN TOP PLATES. 4.4.9. ALL EXTERIOR FRAME WALLS SHALL BE STUCCO FINISH- 7/8"STUCCO FINISH PER ASTM C. 926, APPLY 3 LAYERS W1 TOTAL THICKNESS 7/8' OVER METAL LATH. FIRST 2 LAYERS 3/8"THICK EACH. 3RD LAYER 1/8" THICK 4.4.10. INSTALLATION OF EXTERIOR LATHING & FRAMING SHALL COMPLY TO ASTM C 1063 PER FLORIDA CODE R706.6.1 4.5. FASTENERS AND TIE DOWNS: 4.5.1. FASTENERS AND TIE DOWNS SHALL CONSIST OF BUT ARE NOT LIMITED TO: SHAPES, ANGLES, CHANNELS: ASTM A36/36M 05 Fy = 36 Ksi ROUND METAL PIPE: ASTM A53, GRADE B Fy = 35 Ksi SQUARE METAL TUBING: ASTM A500, GRADE B Fy = 46Ksi HIGH STRENGTH BOLTS: ASTM A325 MACHINE BOLTS: GALVANIZED ASTM A307 4.5.2. SHEET METAL ACCESSORIES SHALL CONFORM TO: Fy = 33KsiWITH G90 GALVANIZED COATING IN ACCORDANCE WITH ASTM A525-87. 4.5.3. NAILS SHALL CONSIST OF: COMMON WIRE NAILS WITH MINIMUM DIAMETER AS FOLLOWS: 8d = 0. 131", 1 Od = 0. 148", 12d = 0. 148", 16d = 0. 162". 4.5.4. ALL FASTENERS AND TIE DOWNS EMBEDDED IN CONCRETE OR USED IN AN EXTERIOR APPLICATION ARE TO RECEIVE AN ANTI -CORROSIVE COATING BY MANUFACTURER PRIOR TO INSTALLATION. 4. & 5. ALL FASTENERS AND TIE DOWNS ARE TO PROVIDE THE UPLIFT CAPACITY CALLED FOR IN THE PLANS ARE A MINIMUM. 4.5.6. ALL FASTENER TIE DOWNS, BEAM HANGERS, JOIST HANGERS, AND FLOOR TRUSS STRAPPING ARE TO BE INSTALLED IN ACCORDANCE WITH THE PLANS AND SPECIFICATIONS. 4.5.7. CONCRETE EMBEDDED'SBOLTS USED FOR UPLIFT ARE TO BE WET SET PRIOR TO INITIAL SET OF THE CONCRETE, SPACING AND ALIGNMENT ARE TO BE IN ACCORDANCE WITH THE DESIGN PLANS, U.N.O. ALTERNATES TO "J' BOLTS ARE NOTED ON PLANS. 4.5.8. CONCRETE EMBEDDED TIE DOWNS USED FOR TRUSS AND WALL UPLIFT ARE TO BE PLACED AROUND EMBEDDED REINFORCING PRIOR TO OR WHILE PLACING GROUT. 4.& MICRO -LAM LUMBER: 4.6.1. MICRO -LAM STRESS GRADES SHALL PROVIDE THE FOLLOWING MINIMUM PROPERTIES: E 2,000,000 PSI Fb 2,950 PSI Ft 1,850 PSI Fc 500 PSI (PERPENDICULAR) Fc 2,700 (PARALLEL) 4.7. STEEL: Fv 285 PSI 4.7.1. INSTALLATION OF ALL STEEL TO BE PERFORMED BY AN EXPERIENCED, QUALIFIED STEELERECTOR. 4.7.2. FABRICATE AND ERECT ALL STRUCTURAL STEEL IN ACCORDANCE WITH A.I.S.C. "SPECIFICATION FOR THE DESIGN, FABRICATION, AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS". 4.7.3. STRUCTURAL STEEL: ASTM A36/36M 05. 4.7.4. STEEL TUBING: ASTM A500, GRADE B. 4.7.5. WELDED CONNECTIONS: E70XX ELECTRODES, MINIMUM SIZE FILLET WELDS 3/16", AWS CERTIFIED WELDERS. CERTIFICATION PAPERS TO BE SUBMITTED UPON REQUEST. 4.7.6. WHERE STEEL BEAMS ARE CONTINUOUS OVER COLUMNS, PROVIDE WEB STIFFENER PLATES ON EACH SIDE OF THE WEB, OF A THICKNESS EQUAL TO BEAM FLANGE THICKNESS, LOCATED AT THE CENTER LINE OF THE TUBE COLUMN. 4.7.7. THE STEEL FRAME IS "NON -SELF SUPPORTING". ADEQUATE TEMPORARY SUPPORT SHALL BE PROIADED BY THE CONTRACTOR UNTIL REQUIRED CONNECTIONS OR 4.8. SOIL ELEMENTS ARE IN PLACE. 4.8.1. MINIMUM SOIL BEARING PRESSURE CAPACITY OF 2000 PSF. FOUNDATIONS HAVE BEEN DESIGNED WITH THE MIN. CAPACITY OF 2000 PSF 4.8.2. ALL SOIL IS TO BE CLEAN & POISONED FOR TERMITES PER FBC 5th ad. (2014), RESIDENTIAL SECTION 133% 4.8.3. SOIL IS TO BE COMPACTED TO 95% MODIFIED PROCTOR AS DEFINED BY ASTM D 1557-02EO1 TERMITE PROTECTION = CONTRACTOR TO USE (1) OF THE TREATMENTS BELOW Borate / Boracore treated lumber Soil Chemical Barrier Method Other treatment - Must specify proposed method and submit documentation, which substantiates the proposed method, is an approved termite protection system or method. OR CHEMICAL SOIL TERMITE TREATMENT IS USED 1 FRC R318.1- "A permanent S n which identifies the termite treatment provider and need for re -inspection a 1Xreatment contract renewal shall be provided. The sign shall be posted near the water heater or electric panel" 2. Condensate and roof downspouts shall discharge at least V-0" away from the building side walls. 3. Inigation/s ' grilder sgstems includin all risers and -0" of the building side wall. spray hea s shall n t be installed w hin 1' 4. FRC R318.7- To provide for inspection for termite infestation, between wall covering and final earth grade shall not be less than 6 inches. Exception: Paint or decorative cementitious finish less than 5/8" thick adhered directly to the foundation wall. 5. FRC R318. 1.1 - Initial treatment shall be done after all excavation and backfill is complete. 6. FIRC R318.1.2 - Soil disturbed after the initial treatment shall be retreated including spaces boxed or formed. 7. FRC R318.1.3 - Boxed areas in concrete floors for subsequent installation of traps etc., shall be made with permanent metal or plastic forms, Permanent forms must be of a size and depth that Will eliminate the disturbance of soil after the initial treatment. 8. FRC R318.1.4 - Minimum 6 mil vapor retarder must be installed to protect against rainfall dilutipri. If rqin�ll occurs b6fore vapor retarder placement, retreatment is require . 9. FRC R318.1.5 - �gn,?rete over our ind mortar along the foundation perimeter e rp c must remove a ore exter or soi treatment. 10. FRC R318.1.6 - Soil treatment must be applied under all exterior concrete or grade within V-0` of the structure sidewalls. 11. FRC R318.1.6 - An exteripir vertical chemical barrier must be installed after construction is complete, including landscaping and irrigation. Any soil disturbed after the vertical baiAer is applied, shall be retreated, 12. FIRC R318.1 - All buildings are required to have pre -construction treatment. 13. FIRC R318.1 - A certificate of compliance must be issued to the building department b i licensed pest control company before a certificate of occupancy will be issued. TUcertificate, of compliance shall state: 'The building has received a complete treatment for the prevention of subterranean termites. The treatment is in accordance with the rules and laws of the Florida Department of Agriculture and Consumer Services". 14. FRC R318.6 - After all work is completed, loose wood and fill must be removed from below and within V-0" of the building. This includes all grade stakes, tub trap boxes, forms, shoring or other cellulose containing material. WORST CASE DESIGN PRESSURE TABLE BUILDING DATA WIND SPEED (ULTIMATE) 140 MPH WIND SPEED (ALLOWABLE) 108 MPH WIND EXPOSURE - "C" (FRC R301) INTERNAL PRESSURE COEFFICIENT= 0.18 ENCLOSED BLDG) BUILDING CATEGORY = 11 DESIGN WIND PRESSURE: (COMPONENT AND CLADDING) WORSTCASE (10 SF - END ZONE) # END ZONE IS ONLY WITHIN 6-101" OF ALL EXTERIOR BUILDING CORNERS WINDOWS AND DOORS 140 MPH + 29.7 PSF / -39.6 PSF (END) U.N.O. CONSTRUCTION + 29.7 PSF / -32.2 PSF (INTERIOR) U.N.O. GARAGE DOORS (V = 140 MPH) TYPE: 513 SINGLE 90 +26.3 PSF / -29.8 PSF DOUBLE 160 +25.2 PSF / -28.1 PSF NOTE: THE WIND PRESSURES LISTED ABOVE ARE ALLOWABLE PRESSURES. NOTE: IT IS THE CONTRACTORS RESPONSIBILITY TO REVIEW ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. FLORIDA DESIGN SOLUTIONS, INC. IS RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF THIS PROJECT ONLY. ANY DISCREPANCY BETWEEN FIELD CONDITIONS, OTHER DESIGN PROFESS I ONALS'SHOP DRAWINGS, CONTRACTORS' BUILDING METHODS, AND THESE SIGNED AND SEALED DRAWINGS MUST BE BROUGHT TO THE ATTENTION OF FLORIDA DESIGN SOLUTIONS, INC. PRIOR TO THE COMMENCEMENT OF CONSTRUCTION. NOTE: GYPSUM BOARD MAY BE INSTALLED USING GWB54 NAILS TO SET IN PLACE. FIELD FASTENING SHOULD BE TYPE "W" 1%" DRYWALL SCREWS AT 12" O.C. FOR CEILINGS AND 1Y811 DRYWALL SCREWS AT 12" O.C. FOR WALLS. ALL ENDS AND EDGES OF WALLBAORD SHALL OCCUR OVER AND BE SCREWED TO SUPPORTS. MAXIMUM SCREW SPACING AT ENDS (EDGES IN VERTICAL APPLICATION) SHALL BE 6" O.C. AT EACH SUPPORT. MINIMUM SCREW NAIL DISTANCEFROM EDGE SHALL BE Y8". THIS SHALL APPLY TO BOTH CEILING AND WALL INSTALLATION. DRYWALL SHIMS SHALL BE USED ONLY WHERE NECESSARY. OPENINGS CUT FOR OUTLETS, SWITCHES, ETC, SHALL BE OF A TOLERANCE THAT CAN BE COVERED ADEQUATELY WITH NORMAL SWITCH PLATES AND COVERS WITHOUT ADDITIONAL TAPING OR CAULKING. DRYWALL SHALL NOT BE INSTALLED WITHOUT PROPER BACKING. NOTE: ALL HEADERS, BEAMS, ETC ARE TO BE SYP #2 OR BETTER AND OR MICROLAM AS INDICATED ON THE DRAWINGS AND CAN NOT BE REVISED. rd-0- ft& -0 Z (0 z 0 Q) 4-J uj 0 U-i 0 W U) C') V) 90 CO r- 0 LU a) P� 0) ce) c cu ce) E 0 9 MIN ca 'D ce) 'C: 04 20 a) 0) UCO) a) LL co 0 6 !� La, a) < '00) 0 CL C) U-) 0 'T -� 6 0q) A N C B D-C If r 00 (o CK�',S, b Z C,, 0- ix :z ut 0 d; U_ LU LLj 0-. 0 < Mill jr 6 F L Z. _ I= LL -MA- N lu e - (5� Uj 11 E] To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code 5th Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. C:, Z 0 P­4 4-J V) '5 Q0 c) > U-) r) C�) V) CO Ln C) z < LL Ln 31 00 E z § z fo ui C:) _J C:) W 0z z <_ E3 com Lu L U z < z z Lu Z 0 LLI Lu cc C/) Mz@ LU Z Z Lr) 0 z Z z 0 -0 Z U-) 0 > z 0 U U-) < 0 ZO cr- rj C/) < LLI W 0 < r4 0 ce z z r_j M 2 Cy LU _j U') ,-I I . . Uj < ozu 0!� U U_ . < LU ro < Z z z M 0 z UJI Z Ln z Lu SCALE AS NOTED DATE 2/24/2014 TECH: MIAMES VERSION No' 10 SHEET NO. SN CORNER OF HOME GARAGE SIDE ROOF DIAPHRAGM NAILING SCHEDULE RIDGE LINE + 4� . . . . . . . . . . . . . . . . . . . . . . + ............. N ............... Zo ............... F +. + 4 . . . . . . . . . ... . . . . . . . . . . . .. . . + + + + + + + !-0-- (TYP.) + + 6'-0" +/ + + 61-0" + + + 4 . . . . + + - + + + + 4 + + + + + + _,",TYP` + + + LU + + + + J + - + + 15/32" CDX in + + + + + + + + + + + + PLYWOOD OR I I 1 1 7/16" OSB + + . . . . + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + F + + 4 . . . . + + + . . . . . . . . . . . + + + /++ ++ + . . . . . . .. + �'--RIDGE LINE 140 MPH (UR) 3 SECOND GUST EXPOSURE "C" WIND ZONE 140 MPH (ult)3 SECOND GUST EXPOSURE "C"WIND ZONE 8d RING SHANK NAILS @ 6" O.C. & 8d RING SHANK NAILS @ 6" O.C. EDGES & 4" O.C. @ GABLE END WALL OR GABLE TRUSS 8d RING SHANK NAILS @ 6- O.C. INTERMEDIATE 0.113 INCH NOMINAL SHANK DIAMETER 0.113 INCH NOMINAL SHANK DIAMETER RING DIAMETER OF 0.012 OVER SHANK DIAMETER RING DIAMETER OF 0.012 OVER SHANK DIAMETER 16 TO 20 RINGS PER INCH 16 TO 20 RINGS PER INCH 0.280 INCH FULL ROUND HEAD DIAMETER 0.280 INCH FULL ROUND HEAD DIAMETER 2 INCH NAIL LENGTH 2 INCH NAIL LENGTH 'GUN NAILS MAY BE USED FOR 8d RING SHANK NAILS 0.1 13x 2x 3/8" RING SHANK COIL NOTE: 1) SEE STRUCTURAL NOTES FOR SHEATHING SPECIFICATIONS AND WIND SPEED. 2) END JOINTS OF THE ROOF SHEATHING SHALL BE STAGGERED AND OCCUR OVER FRAMING MEMBER. 3) SCHEDULE ASSUMES SHEATHING IS FASTENED DIRECTLY TO SOUTHERN YELLOW PINE OR DOUGLAS FIR OR BETTER. IF ROOF FRAMING CONSISTS OF A LESSER GRADE OF LUMBER, CONTRACTOR MUST CONTACT ENGINEER OF RECORD FOR ALTERNATE NAJLING PATTERN. Backer and Filler Block Dimensions BC10JOist Backer Block Thickness Filler Block Thickness Series 3/4" or 7/8" 5000s 1.8/1-7 wood panels Two 3/4" wood panels or 2 x 1 -1 /8" or two 1/2" 6000S 1.8/1.7 wood panels 2 x + 5/8" or 3/4" wood panel 1-1 /8" or two 1/2" 6500s 1.8/1.7 wood panels 2 x - + 5/8" or 3/4" wood panel 1- 1 /8" or two 1/2" 602.0 wood panels 2 x _ + 5/8" or 3/4" wood panel 902.0 2 x - lumber Double 2 x - lumber DOUBLE JOIST CONSTRUCTION (Not required If both loaded equally from above) Filler blocking 1/8"gap NIt FILL CELL STD. 900 HOOK F BOND BEAM ......... LU ... ......... t STD. 90' F CONT. #5 CONT. #5 HOOK BAR BAR ;�� A #5 CONT. ..................... FROM FOUNDATION TO HIGHEST -------- I BOND BEAM BOND BEAM STEP SCALE: N.T.S. 2nd FLOOR INTERIORIEXT WALL SEE PLAN FOR MORE INFO CONT. BASE PLATE BEARING COLUMN SEE PLAN FOR REQ'D PLYWOOD FLOOR COLUMN AND SHEATHING PER PLAN CONNECTION__,,� TJI TO BE CUT TO ALLOW FOR BLOCKING/TJI MASONRY WALL OR INTERIOR BRG. WALL TJI PER PLAN OTHERWISE SOLID BLOCKING TO MATCH # OF 2nd FLOOR Solid bil ck all posts from STUDS above to bearing below. INT. BRIG. WALL SECTIONU N.T.S. 1/8" min. Small gap 2" min. 2" max. " max. O'D Solid block all IDOStS from Clinch nails when possible 1) Support back of web during nailing to prevent damage to web -flange connection. 2) Block solid between joists for full length of span. Tight fit 3) Leave 1/8" gap between top of filler blocking and bottom of top flange. 4) Place joists together and nail from each side with 2 rows of 1 Od nails 2x4/Plywood/OSB web stiffener 2" min. 2x : CONTRACTOR TO PROVIDE 2x TO FILL THE HEIGHT at 12" o.c., clinched when possible. Stagger rows from opposite required when indicated or 4" max. - Hangers with side nailing. OF THE JOIST ASA REQUIRED LEAVING Yj'GAP @ TOP sides by 6". - Hangers with sides not containing top flange of joist. WEB STIFFENER - Birdsmouth cuts. N.T.S. DOUBLE JOIST CONNECTION - Under 2nd floor column w/ loads N.T.S. higher than 15001b SQUASH BLOCKS AT INTERIOR BEARING Vertical load transfer =1 900 pif max along load bearing wall. Load bearing wall must stack *Non -stacking walls over squash=20 blocks and wall or beam below.* require additional consideration. Check local building k L' 0 w EL-70 code for appropriate details in One 1 Od box areas=20 of high or--20 sinler lateral load. nail each side 101-011 at bearing. TANK -LESS W/H H C G 000 51-011 STUB -OUT FOR 9 1-011 9 [0 GAS METER 0 0 C14 1 0 MEASUREMENTS ARE FROM FINISHED FLOOR • ROUGH -IN GAS TO RIGHT (ALWAYS) - 12" OFF -CENTER • ROUGH -IN ELECTRIC TO LEFT (ALWAYS) - 12" OFF -CENTER GAS CONNECTION DETAIL "ONLY APPLIES TO HILLSBOROUGH AND PASCO COUNTY" RAFTER SPAN TABLE MEMBER SIZE AND SPACING MAXIMUM LENGTH MEMBER CONNECTIONS* 2" X 4- @ 16" O.C. T.5" (2) 16d TOENAILS 2" X 6' @ 16" O�C. 1 U-811 (2) 16d TOENAILS 2" X 8" @ 16- O.C. 13'-9" (3) 16d TOENAILS 2" X 10" @ 16" O.C. 16-5" (1) USP HTW20 OR (3) 16d TOENAILS 2" X 12- @ 16" O.C. 19'-3" (1) USP HTW20 OR (4) 16d TOENAILS 2" X 4" @ 24" O.C. 6'-1- (2) 16d TOENAILS 211 X 6" @ 24" O.C. 81-61f (2) 16d TOENAILS 2" X 8" @ 24' O.C. 111-01, (2) 16d TOENAILS 2" X 10" @ 24" O.C. 13'-0" (3) 16d TOENAILS 2" X 12" @ 24" O.C. 15'-4" (1) USP HTW20 OR (3) 16d TOENAILS TOENAIL CONNECTIONS DESIGNED FOR SHEAR ONLY (i.e. RAFTER TO RIDGEBEAM). SOUTHERN YELLOW PINE, 55 PSF LOADING Squash block (2x4 minimum)--/ Bearing wall, Versa -Lam LVL or Glularn Beam NO HOLES (EXCEPT KNOCKOUTS) ALLOWED IN BEARING ZONES DO NOT cut, notch or drill flanges Boise Joist Blocking I ka'A"(1f1rill nAil.q;A A" n r-_ Q�� Provide adequate bearing for each lapped joist. Od nails SECTION @ INT. BRG. WALL N.T.S. MINIMUM SPACING 2x GREATEST DIMENSION OF LARGEST HOLE D (see table below) (KNOCKOUT EXEMPTS) D (see table below) Web Stiffemer Fastener Schedule Joist B an ocation Series Depth End Intermediate B Cl 5000s" 9-112" 11-7/8" 2-8d- 2-8d 2-8d 3-8d 5-8d BCI 6000so BCl 6500SP 9-1/2" 11 -7/8" 2-8d 2-8d 2-8d I - 8_ I 14" 2-8d I 5-8d — 16" 2-8d 6-8d BCl 60e 11-7/8" 2-8d 3-8d 14- 2-8d 5-8d 16" 2-8d 6-8d BCI 90sQ9 11-7/8" 3-16d 3-16d 14" 5-16d -5-16d 16" 6-16d 6-16d . BLOCKING PANEL, INTERIOR Vertical load transfer =1900 pff max. along bearing wall Required on interior walls: - for vertical load transfer Plumbing when load bearing - for lateral support when joists meet over wall, or wall stacks directly over wall or beam below Load bearing wall must stack over blocking and wall or beam below.* Joist When joists meet over wall, provide 'oc Whe 13/4" minimum bearing for each. I -Joist can be offset up to 3" to avoid vertical plumbing L 3" max JOISTS OFFSET N.T.S. Use 1 Odx3" nails at 6"o.c. for all joist blocking panel *Non -stacking walls require additional consideration, N M-T " A ROUND HOLE MAY DO NOT CUT HOLES 6" 6" EVER LA 6' BE CUT ANYWHERE IN 7= CANTIL RGER THAN THE WEB. PROVIDE AT ROUND IN I LEAST 3"OF CLEARANCE CANTILEVERS. FROM OTHER HOLES 2 MINIMUM DISTANCE FROM SUPPORT, LISTED BELOW, IS REQUIRED FOR ALL HOLED GREATER THAN 1Y Arry 16'joist 12 1 1--g- I T-11" I 11'-Z' I 1�-Z' 1 V-3- 11'-9' 1 2�4' 12-11"1 3-7- 14-2' 1 4-9- 1 6-4- 1 16 -V-0" I' -I" I,-Z. T-21. f-7. 2-6. 3-21 3-101, 4-91 6-71 6-41 T-171 20 1!-U. I,-r 3-a' 14-9: W-10" 19-11" 6-11" 17'-11" 8'-11" 24 T-9' 11�4' T-Z'I 11�-3" 12-6' 3-7 14-9 6-16'. Tz. 9-41 "1 NOTES: 1. JOISTS MUST BE PROPERLY DESIGNED TO MEET BUILDING CODE REQUIREMENTS. 2. TABLE IS FOR UNIFORMLY LOADED MAXIMUM LOADS OF 40 PSL(LIVE) AND 15 PSF (DEAD) ON SIMPLE SPAN APPLICATIONS ONLY. 3. REFER TO JOIST SPECIFIER GUIDE FOR INSTALLATION AND OTHER INFO. 4. SELECT A TABLE ROW BASED ON JOIST DEPTH AND THE ACTUAL JOIST SPAN ROUNDED UP TO THE NEAREST TABLE SPAN. SCAN ACROSS THE ROW TO THE COLUMN HEADED BY THE APPROPRIATE ROUND HOLE DIAMETER OR RECTANGULAR HOLE SIDE. USE THE LONGEST SIDE OF A RECTANGULAR HOLE. THE TABLE VALUES IS THE CLOSEST THAT THE CENTERLINE OF THE NEAREST SUPPORT. 5. THE ENTIRE WEB MAY BE CUT OUT. DO NOT CUT THE FLANGES. HOLES APPLY TO EITHER SINGLE OR MULTIPLE JOISTS IN REPETITIVE MEMBER CONDITIONS. 6. FOR MULTIPLE HOLES, THE AMOUNT OF UNCUT WEB BETWEEN HOLES MUST EQUAL AT LEAST TWICE THE DIAMETER (OR LONGEST SIDE) OF THE LARGEST HOLE. 7. 1Y2"ROUND KNOCKOUTS IN THE WEB MAY BE REMOVED BY USING A SHORT PIECE OF METAL PIPE AND HAMMER. 8. HOLES MAY BE POSITIONED VERTICALLY ANYWHERE IN THE WEB. THE JOIST MAY BE SET WITH THE lj/2" KNOCKOUT HOLES TURNED WITHER UP OR DOWN. 9. THIS TABLE WAS DESIGNED TO APPLY TO THE DESIGN TO APPLY TO THE DESIGN CONDITIONS COVERED BY TABLES ELSEWHERE IN HIS PUBLICATION. USE THE BC CALC SOFTWARE TO CHECK OTHER HOLE SIZES OR HOLES UNDER OTHER DESIGN CONDITIONS. IT MAY BE POSSIBLE TO EXCEED THE LIMITATIONS OF THIS TABLE BY ANALYZING A SPECIFIC APPLICATION WITH THE BC CALC SOFTWARE. HOLE CUTTING CHART N.T.S. Joist hanger U M THF 5/811 BOL RTRUSS OP PLATE I.0 TYPICAL USP MUGT15 TO BUILT—UP COLUMN DETAIL TYPICAL HUS INSTALLATION AIN. EMBEDMENT SCHEDULEFOR AND QUANTITY )IFFASTENERS TYPICAL HTA 20-18 HTA 20 INSTALLATION A/C CHASE 4" PVC SLEEVE THRU STEM WALL Backer block (12" wide min.) 11-11 1:_-:11 I I Nail with 10- 1 Od nails. nstall tight to top flange. 4 '7.,�- SLEEVE THRU STEM SEE PLAN FOR 4 4 -40 .4' T. 7 FOUNDATION INFO 4' STEM FOUNDATION Filler block. Nail with 10-1 Od nails. Backer block required where top mount hanger load exceeds 250 lbs. Install tight to top flange. 1/4"-2" gap --- AV _"A� -1 Backer Block "Top Mount" "Face Mount" Backer block shall be tight Backer block shall be fight to bottom of top flange with to top of bottom flange with 1/4%2" gap at top of bottom 114"-2" gap at bottom of top flange. flange. eb stiffner as Web stiffeners are not required when top required if hanger flange is laterally supported by joist hanger. doesn't meet height re' dc 4h r requirements -0 , 6 X Joist D depth I —JOISTS BUCKETS N.T.S. GRADE — r-REINF. SEE PLAN (2) #5 REBAR A/C CHASE 4 SLEEVE THRU FOOTING MONO FOUNDATION TYP. FND. PENETRATIONS SCALE: N.T.S. HTA 20-18 HTA 20 INSTALLATION @ MID SPAN LOCATION OF SECOND RT16 :3 NOTE: UPLIFT VALUE IS BASED ON S.P.F. USP RT16 USING 16-8d x1 1/2" NAILS UPLIFT 1030# TYPICAL RT16 INSTALLATION TYPICAL MTW INSTALLATION TOP (2) #5's x 4'-0" CENETERED @ PIPE PENETRATION PLUMBING LINE PVC OR SCH40 SLEEVE PIPE VERTICAL THRU FND. C OR SCH40 SLEEVE PV sx CENETERED @ PIP PLUMBING LINE PENETRATIO /F L A A A SEE FND. PLN. SIZE & REINF. PIPE PERPENDICULAR TO FND. TOP (2) #5's x 4'-0" CENETERED @ PIPE PENETRATION PVC OR SCH40 SLEEVE PLUMBING LINE A 4 4-1 ..:1 �d A SEE FND. PLN. SIZE & REINF. ce) 0 05203'% k I= WJ z < CL 71 V) 0 00 Lu 0 ULJ 12 E Of V) 0 0 to CQ 00 M M I, - C14 CD M LU t­ E 0 0) Ce) r_ M co 270 M r N 00 q :r a) W - () W 0 iz co - co 0 i:�- < 0 CO C) 0, 0 V *;l. CL - <0 A I N c N C D.0 C-4 C5 CO) z a.,-4 p o�. SL L� - F W.-I MV uLi "ir 1L Neff WE < P_ 6 -- z tE ��.R F L( M IV ca LU V F.7 El I: i It f - To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code 5th Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. C:) C:> Z ri 0 a) N " 4-J C) V) , 3 "o C:) > p N Lo fO Ln z 5- 0 U) U_ fy) fu T__1 cl� U 0�. z < 00 z § E — R3 z LU C) _J 0 W 110 1- mi �5 0, zg z 181 0 61 '. U Z 0.0 Cl) cz 8W u_ CD u, W z @ UJ Z Z 8"' 8 L0 0 z z z 0 -0 2: Ln < 0 2: > z 0 Q 0 < LU 8* 0 tu- R ZO UC) CU) 6 R M 0 �1 Z:Q LU < r�4 0 z z C"i C=y) . LU _J Lr) T-4 I 6i 2: Lij < 'S, z < ff� 5 �_ z 0 058 U. 0" uJ 110 M Z z 0� 0 z ca 0 T-4 r� z U LU Z 2 V) z r_1 T__1 SCALE AS NOTED DATE 2/24/2014 TECH: MIAMES VERSION N 0' 10 SHEET NO. SN 1 1� A 1 111 I'l 1 1. 1 1 1 ii li&,, 7r7T—_1I_ii EF 11 1 M.. FOR UNDERLAYMENT REQUIREMENTS SEE R905. 12 21!7PTYP') VARIES .) � ��� /ZZ-11" INSULA TION LE 5/8" OR 1/2" HIGH ---- STRENGTH CEILING BOARD PER CODE (OR 5/8" GYP. TYPE "X"@ GARAGE W/A HABITABLE ROOM ABOVE) W/DRYWALL SCREWS 17- O.C. CEILING & 8" O.C. WALLS INSULATION PER CHART ON FLOOR PLAN 1x2 P.T. HORIZONTAL-J NAILER STD. 90-HOOK (SEE DETAIL 2x #2 SPF STUDS - @ 16" O.C. W/ (2) 16d TOENAILS T & B 2x P.T. PLATE (1) ROW 2x BLOCKING @ MID HGT. FOR WALL HGT. :5 8'-6". (2) ROWS 2x BLOCKING @ 3rd FITS FOR WALL HGT, > 8'-6". 1/2' GYP. WB (MIN.) I GARAGE SIDE IF APPLICABLE. 1/4" DIA. X 3 1/4" TAPCONS @ 24" O/C & 16" MAX FROM END OF 2 x PLATE E (1) LAYER TYPE 11 (#30) 1 ffo I - %.ji a - 6 x 6 W1.4 x W1.4 UNDERLAYMENT FOR ROOF CHAIRS (TYP.) WWF OR FIBERMESH PITCH >412 (2) LAYERS TYPE I OR TYPE 11 (#15 OR #30) UNDERLAYMENT 9 I> I % r %%JUr' rI 1 Vn 1+: 14 VI"N Lr-00 AIR PRE ENGINEERED WOOD TRUSS @ 24" O.C. U.N.O. - URRICANE ANCHOR @ EACH ;USS (SEE UPLIFT SCHED.) W/ METAL PL. UNDER EA. TRUSS MOISTURE BARRIER TYPICAL INTERIOR BEARING SHINGLE ROOF 7/16" O.S.B. MIN. SEE ROOF WALL WOUT UPLIFT (*GG NAILING SCHEDULE ON SHT. SN1 SEE TYP. WALL SECTION SCALE: 314"=1'-0" � ELEV. VARIESAi__� FOR ADDITIONAL SLAB �S3 I INFORMATION. �--ALUMINUM DRIP iiii_!DGE ALUMINUM FASCIA L2x SUB FASCIA 5/8"OR 1/2" HIGH STRENGTH ­` '-TRUSS BOTTOM CHORD OR 2x4 BLOCKING 518"OR 1/2" HIGH STRENGTH - (U.N.O.) (OR %" GYP. TYPE "i @ W/ 2-16d TOE NAILS I EACH END (U.N.O.) (OR V GYP. TYPE 7" @ GARAGE W/A HABITABLE ROOM ABOVE) EE UPLIFT SCHEDULE FOR UPLIFT GARAGE W/A HABITABLE ROOM S.P.F. DOUBLE CONNECTIONS. PROVIDE (1) USP HTW20 WHEN ABOVE) TOP PLATE TRUSS ALIGNED WITH STUD BELOW S.P.F. DOUBLE Wx&i 6" NOMINAL BLOCK WITH TOP PLATE 3/8" MORTAR BETWEEN COURSES USP SPT24 CONNECTOR x S.P.F. (OR EQUAL) STUDS @ 16" O.C. U.N.O. USP SPT24 1/2" CDX PLYWOOD OR 7/16" O.S.B. CONNECTOR SHEATHING REaD. FOR ALL ,�1) ROW 2x BLOCKING @ MID HGT. FOR WALL EXTERIOR OR SHEAR WALLS AS HGT. < 8'-1 (2) ROWS 2x BLOCKING @ 3rd PTS INDICATED ON THE PLAN. ATTACH FOR WALL HGT. > V-13". SHEATHING W/ 8d COMMON NAILS @ NSULATION PER CHART ON FLOOR PLAN 4" O.C. @ BOUNDARIES, 6- O.C. @ MORTAR BETWEEN EDGES, AND @ 12" O.C. @ FIELD F SLAB & BLOCK 5/8"' x 1 0""J" BOLT @ 24" O.C. W/ SP SPT22 CONNECTOR 5/8110 x 10" "1 BOLT @ 24" O.C. W/ - 2"x3/16" PLATE WASHER (TYP.) 2"*0/16" PLATE WASHER (TYP.) (ALT: 1/2"xl 2" TITEN HD @ 24" Cn (ALT: 1/2"x1l 2" TITEN HD @ 24" 2x P.T. BOTTOM PLATE :IF I ELEV. 0'-0" AK O.C. OR 5/8"xl O'WEDGE ANCHOR x 6 W1.4 x W1.4 O.C. OR 5/8"x10'WEDGE ANCHOR A.F.F. " O.C.) @ 24" O.C.) @ 24 WWF OR FIBERMESH 0 4 3 1/2" MIN. ELEV. 4 3 1/2" 4 2x4 CONT CONT- 4 1 4 4 A. F. �F�o U_ 4 GARAGE DEPTH VARIES 1714 ;0 1/2"(min.).- gg lj.=�2-L I_' AMI 1 F= I WWI' (2) #5 CONT 4" 81: U.N.O. MIN. GARAGE SLAB AT STEP rB TYPICAL BEARING WALL @ STEP (ED SHEARWA "SHEAR WALL" SCALE: 3/4"=V-0" SCALE: 3/4"=V-0" S3 1/2"OR 7116" OSB MIN. PLYWOOD SHEATHING - NAILED W1 8d COMMON NAILS @ 4" O/C 2x S.P.F. STUDS 1 11 O.C. BOUNDARIES, 6" O/C EDGES, AND 12" O/C FIELD. EE SOFFIT 4 2x STUD SHEAR WALL REQUIRES 2x BLOCKING @ SEAMS. SHEET LOAD BEARING OR - - -) MAIA10 rNIT ') 01 nt-VIKIr_' C S3 ;0 3 1/2" MIN. 1/2"(min.)- 4" (2) #5 CONT. 1 4T 11-11 1-'4111 IF I U.N.O. MIN. TYPICAL BEARING WALL @ STEP SCALE: 3/4"=V-0" MASONRY WALL AND--- > 1.1 PAD FOOTING 8"MASONRYWALL EXTEND FILL CELLS T PAD CONT. FOOTING STEEL MAT REINFORCING. GRADE .4 4 11110 LU 10 11 z LU LU Z5a. LU LU CD LU 0 !10 0, z 0 in LL /,6.. - 4 oOOTING �= 2 BEYOND PAD REINFORCEMENTJ_ 1 3" MIN . CLEARANCE (SEE SCHEDULE) FOOTING WIDTH SEE SCHEDULE PATIO COLUMN FTG. DETAIL rN SCALE: N.T.S. '\,,13�_ (1) ROW 2x BLOCKING @ MID HGT. 8"16" KN' EXTERIOR WALL 81, C M U k ; A �W_ 2x STUDS @ 16" 1 NOTE: FOR WALL HGT. 15 V-16". (2) OCK-OUT THIRD POINTS ULATION PER CHART ON FLOOR PLAN ROWS 2x BLOCKING @ 3rd FITS BLOCK W1 1#5 CONT. 1 "x P. T.' S`T U D SEE SECTION C/S3 FOR FOR WALL HGT. > 8'-6". 2 I FILLED SOLID W/GROUT SEE CC/S3 OR #5 VERT. IN FILLED CELL 7/8" STUCCO FINISH PER ASTM C. 926 APPLY 3 ADDITIONAL INFORMATION 1/2" GYP. WB (MIN.) @ GARAGE 04 LAYERS W/ TOTAL THICKNESS 7/8" OVER U 8" C.M.U. TYPICAL G/S3 FOR ANCHOR 5/8" x 10" "J" BOLT @ 24" O/C W/ 2"X 3/16" METAL LATH. FIRST 2 LAYERS 3/8" THICK EACH, CONTINUOUS TO FOOTER BELOW 90 ROOK DETAIL USP SPT22 CONNECTOR SIDE IF APPLICABLE. BOLT INFO. rl 5/8"- EXPANSION BOLT @24 " O.C. 5/8"1 "J" BOLTS BOLT PLATE WASHER TYPICAL 3RD LAYER 1/8" THICK. (a) K.O. BLOCK (IF NO UP LIFT 03N @ 24" O.C. VERT. OR /,_IJSP SPT22 @ EA. STUD 2x P.T. PLATE W1 7 EMBEDMENT (MIN. SHEAR 5/8" x 6" EPDXY BOLT OR D� "S" MORTAR WALL SEE GG/S3) if It MIN. 2500 PSI CONCRETE SLAB W/ COArIli Ali D /-3500#, MIN. TENSION 2600#) FINISH 1 x2 PT WD FURRING @ 24" O.C. 1/2" GYPSUM WALLBOARD (1) #5 VERT. IN FILL U.N.O. CELLS(SEE FOUNDATION PLAN FOR LOCATIONS) 1x4 P.T. BASE NAILER 4"x4" INSPECTION 3 1/4" BASEBOARD PORT AT EACH FILLED CELL TYPICAL MIN. 2500 PSI CONC. SLAB v) AT GARAGE CONTRACTOR MIN PSI MAY VARY PER TO CUT BLOCK OR POUR MUNICIPALITY. CURB DUE TO SLOPE CONCRETE SLAB W/ 6X6 /-NOTE:EXTEND W11AXW1.4 WWF OR "FIBERMESH" DECO FINISH 4" to 6" BELOW GRADE 00 Cl) 6 MIL VAPOR BARRIER 4 C14 COMP. SOIL.. (COMPACTED 95% MODIFIED FIR TOR f IY4 ASTM D 1557) 3" MIN. CLR. (2) #5 REBAR CONT._/ ON 3" CHAIRS TYP. 4"1 V-4" STD. 90 HOOK (SEE U.N.O. I DETAIL) TYPICAL WALL SECTION rA SCALE: 3/4" = V-0i" �3 15(w­ NO (6)1/4 x3 1/4 TAPCONS 2X P.T. PLATE 20" MIN. LAP [24" MIN. LAP] E 6 x 6 W1.4 x W1.4 WWF OR #5 REINFORCING X *USP SPT22 TYP. SPACED EVENLY BOLTS 6" MAX FROM 6 x 6 W1.4 x W1.4 FIBERMESH BAR c1q WEEP SCREED INSTALLED X to END OF 2" x PLATE WWF OR FIBERMESH ----2x P.T. PLATE PER MANUF. X ASSUMED FINISHED N"`-#3 OR #4 REINFORCING BAR X GRADE 40 MIN. ll 40ksi X a. [GRADE 60 MIN. Fr- 61 co 00 X I> FINISH GRADE �GRADE #3 & #4 LAP SPLICE MONO OR STEMWALL Cf) 25- MIN. LAP [30- MIN. LAP] W= x I X I I FOOTING MONO SHOWN 2 - 6 �1 r I -[I - I- \ .. I I /Imil 00 A X 'I W U) 6 MIL VAPOR BARRIER FOR CLARITY R 17/8" F-1 I 1=1 I IEI I H� ----#5 REINFORCING BAR CN #5 LAP SPLICE (2) #5 CONT. NOTE: MIN. LAP] ON 3" CHAI �S 36" MIN. LAP [36 *FOR BEARING WALL COMP. SOIL. (COMPACTED TO (TYP.) 101, W/ UPLIFT ONLY r=j�W-IrmWI-rF 95% MODIFIED PROCTOR ASTM _�'-#113 REINFORCING BAR #5 STD. 90 HOOK D 1557) 111zy­,­ X., ''M E I I=" , 4" V-411 I �=_.,Ll rF, LI I rl I I— I r III TYPICAL INTERIOR BEARING L�=,,j =1 III - #6 LAP SPLICE WALL W/ UPLIFT FRAME WALL TO C.M.U. WALL CONNECTION D TYPICAL EXTERIOR FRAME WALL FOOTING REBAR DETAILS rG SEE TYP. WALL SECTION FOR ADDITIONAL SLAB INFORMATION. 6 x 6 W1.4 x W1.4 31/2" WWF OR FIBERMESH in.) 4"---, A .0. r I 1 1-1 1 1-1 1 ixx3rrTx'2 7171=1 I III I 1� I rK SCALE: 3/4"=V-0" S3 GRADE I 11 1=14 -I-4LIT-F�1 #5 REBAR w/ OPT. MIN. TYPICAL THICKENED SLAB EDGE L SCALE: 3/4"=1"-0" S3 OPT: DEPRESS SLAB 5Y2" DEEP A ND 6" BEYOND DOOR TO RECEIVE PAVERS/ DRIVEWAY BLOCK WALL BEYOND BLOCK WALL BEYOND CONCRETE SLAB EXPANSION JOINT PAVERS� 14" O.H.D. RECESS - 1311 -O.H.D. RECESS 1. A: M 0? E-1 4 .401 F SEEA/S30RJ/S6-` -1=71 lllii�lll 11 1 1- SEE A/S3 OR J/S6 L IT�3"MIN. CLEARANCE IT _L L rl ��M FOR REINF. INFO. 3" MIN. CLEARANCE FOR REINF. INFO. 1',4" (1 STORY) 1 V-8" (1 STORY w/ DEPRESSED SLAB OPT.) 1'4" (1 STORY) 1-18" (2 STOR) V-81" (2 STORY) GARAGE DOOR SLAB RECESS GARAGE DOOR SLAB RECESS ri SEE TYP. WALL SECTION FOR SCALE: N.T.S. SEE TYP. WALL SECTION FOR SCALE: N.T.S. ADDITIONAL INFORMATION. ADDITIONAL INFORMATION. SCALE: 3/4"=V-0" SCALE: N.T.S. SCALE: 3/4"=1'4' VARIES SEE PLAN 11/2" RECESS FOR 6 x 6 W1 .4 x W1.4 S.G.D. (U.N.O.) WWF OR FIBERMESH !Z�I 10d NAILS TO TRUSS TOP CHORD CID FRAME -DOWN FALSE BEAM w/ (3) SEE ROOF PLAN AT 24" O.C. MAX. x:1 FOR TRUSS I R x CONNECTION INFO 4 4 SEE PLAN FO x TOP OF BEAM "i & LAYOUT DESIGN �z SEE ROOF PLAN q' A 7 FOR STRUCTURAL BEAM SIZE & g TH= //-�,14 TPI CONNECTION INFO 7 t 9 2X4 #2 SYP P.T. FRAMING W/ MIN 7/16" O.S.B. SHEATHING SEE A/S3/J/S6 8- COLUMN LOCATION z ATTACHED PER NAILING FOR REINF. INFO. (1) 9 OtIuCrNil III C: OPTION #1 1/2" GYP. BD. § -d-11 I I P.T. 2x _j SLAB INFORMATION. HOLD GYP. BD. ::� W 2" F5 W 1/2" FROM SLAB SLAB STEP & RECESS (cD S.G.D. ��M 01.011 CONT. BEAD SEALANT SEE FLOOR PLAN FOR All j>K1 -zi SCALE: 3/4"=Vi � S3 INTERIOR 2X STU -3 1/2" GARAC 1/2" G)I` CONCRETE NAILS W 11/2 W/ DR" EMBEDMENT @ 12" O.C. STAGGERED, FROM BOTTOM INSUU PLATE TO CONCRETE ON FL( (MIN. SHEAR 180# MIN. CONT. TENSION 120#) CONCRETE SLAB 6x6VY WWF C 00 1=1 I 7L_`T_jj=j r� * * < 6 MIL VAPOR I I ILE, BARRIER 1411.411 INTERIOR WALL SLAB STEP NON-BRG. rK SCALE: 3/4"=V-0" Is �', S3 SQUARE CMU BLOCK BASE, SIZE VARIES PER PLAN w/ MIN. (2) #5 VERTICALS FILLED SOLID SEE TYP. WALL SECTION FOR ADDITIONAL SLAB INFORMATION. Q'i FIN. FLR.jk IV I _` z z V) (D i C-/) 4-J u, M U 0 LU 0 0) Cl) 00 I cm M C ICU M E T 'S cO4 0 0 0 0 FL CO (D 0 W U) CL C) (3) L < 6 n A-L N C B-D C A -NE 0 z ce) -3- N Cv v IM, L z20 -0 CR HIM e LL F z 01 4 3z%l 114"1 fit! E] To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code 5th Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. 10 CD Z r-j 0 a) N > C:) p 4-;- N 170 Lr) z Ln 2: a) 0 Ln < L_ LL CL e-s re) ce U CL z < § E z z WUJI 10 C:) 0 z < Z, 0 Z.--< F- �E.zz rz , �q u-, W E -L '.) -, M 0 V) Z Z z Ln 0 z ­0 V) �r a! Lr) Z F- r-4 0 > 0 U C, L, wo 0 B � 0- 2� LL. z .'a - LU Ci Z z r-4 =,_0 Z Z.= " LU L0 W, =Z, z 8 U 1.0 Lu �, < cl: 8 < z Luz z z Z M LU 0 tu rn SCALE AS NOTED DATE 2/24/2014 TECH: MIAMES VERSION NO 10 SHEET NO. S3 (MONO) TRIM PER PLAN BRICK PAVERS or SLAB PER COMMUNITY SPECS 0 TRUSS BOTTOM CHORD OR 2x4 BLOCKING W/ 2-16d TOE NAILS I EACH END SEE UPLIFT SCHEDULE FOR UPLIFT CONNECTIONS. PROVIDE (1) USP HTW20 WHEN TRUSS ALIGNED WITH STUD BELOW -2"x S.P.F. (OR EQUAL) STUDS 116" O.C. U.N.O. ROW 2x BLOCKING @ MID HGT. FOR WALL HGT. < V-13". (2) ROWS 2x BLOCKING @ 3rd PTS FOR WALL HGT. > V-6". --4NSULATION PER CHART ON FLOOR PLAN -USP SPT22 CONNECTOR x P.T. BOTTOM PLATE 6 x 6 W1.4 x W1.4 WW`F OR FIBERMESH Zi I MUU I 11i 1_,VLi WI-t & BASE CONNECTION INFO. SECURE 2x4 P.T. BTM. PLATE w/ 1/4"x3" TAPCONS AT 8" O.C. 12 (TYP) SEE ELEV. I USP SPT24 @ EA. STUD CRICKET AS REQUIRED SINGLE 2x CONT. BASE (2) 2x6 OR (2) 2x8 TOP PLATE SEE PLAN (2) 2x HEADER TO SIT 2x6 / W WALL BEYOND FLUSH TO THE OUTSIDE SEE PLAN FOR HEADER SEE PLAN FOR SIZE CONNECTION -------2x DEAD WOOD @ MID POINT w/ (3) 12d TONEAILS SPACED DOUBLE 2x TOP EVENLY PLATE — HEADER FLUSH TO OUTSIDE OPTION 2x BLOCKING @ EACH END W/ 10d @ 4" O.C. FROM EACH HEADER FACE 2 4' t 0 BLOCKING T --(2) 2x HEADER PER PLAN 2x BOTTOM PLATE W/(1) 10d @ 8" 1A1111 IVARIES O.C. TO EACH HEADER FACE 2 x 6 (MIN.) FRAME WALL HEADER DETAIL SCALE: N.T.S. ---SEE TYPICAL WALL SECTION PRE-ENGINEERED WOOD TRUSSES @ 24- O/C UPLIFT CONNECTOR (SEE SCHEDULE) KNOCK -OUT — BLOCK W/ (1 MHRI PWA _=: .10 TOP PLATE 2x S.P.F. STUDS @ 16" O.C. SINGLE 2x CONT. TOP PLATE W/ (2) 12d INTO TRUSS ABOVE 2x CLOSURE WALL W/ STUDS @ 16" O.C. W/ (3) 10d TOENAILS T&B AS REQ'D 2x BLOCKING @ MID + POINT EVERY OTHER S + STUD W1 (3) 1 Od NAI PLATE W1 (2) 16d TO TRUSS BELOW 1/2" EXTERIOR GRADE SHEATHING FASTENED TO TRUSSES WITH 8d COMMON WIRE NAILS @ 4" O/C BOUNDARIES 6" O/C EDGES & 8" O/C FIELD USP SPT22 @ EA. STUD 2x P.T. PLATE 5/8" x 10" "J" BOLT @ 24" O/C MAX W/ 8" EMBEDMENT 8"X8"X1 6" K.O. BLOCK W/ 1 #5 CONT. AND FILLED SOLID W/GROUT 1 #5 VERT. IN CONC. FILLED CELL W1 STD. 90AHOOK IN K.O. BLOCK KNEE WALL ABOVE MASONRY WALL DETAIL MOUNTING BASE NOT SHOWN FOR CLARITY SEE DETAIL KIS4 SEAT FOR BLOCK IS POURED, IN PLACE CONCRETE GARAGE FLOOR SLAB TROWEL FINISH SEE GENERALNOTES SLOPE FORWARD FOR DRAINAGE BLOCKING (TYP.) \—ROOFTRUSS UPLIFT CONNECTOR (SEE SCHEDULE) MOISTURE BARRIER SCALE: N.T.S. Z SEE PLAN FOR FOOTING _"11� DIMENSIONS GARAGE ENTRY FINISHED MASONRY DETAIL SCALE: N.T.S. VENT OR 2ND FLOOR 1/2" MINIMUM CEMENT FINISH TYPICAL C.M.U. WALL STANDARD 3" DIA. TEE 3/4" FURRING STRIPS THREADED 3" DIA. EXTENSION 1/2" GYPSUM BOARD SCREW OFF CAP (3- DIA.) W/ DRYWALL SCREWS FOR CLEAN -OUT @ 8" O.C. OR 4d MIN. EXTENSION FROM DRYWALL NAILS EXTERIOR FACE OF BLOCK WALL IS 11/2" MAXIMUM EXTENSION FROM EXTERIOR FACE OF BLOCK WALL IS 2 1/4" DRAIN WALL CLEAN -OUT rA SCALE: N.T.S. REFER TO WINDOW PRODUCT APPROVAL SHEETS FOR INSTALLATION INFORMATION BY MANUFACTURER. TYPICAL SECTION THRU WINDOW NOTCH LINTEL WHERE REQUIRED FOR CONCRETE PLACEMENT 7 STD. 9d'HOOK-/8, LINTEL BEAM W/ (1) #5 CONT. IN OPENINGS GREATER THAN 6'-O"WIDE (U.N.O. ON PLAN) OPENING FILLED CELL W1 (1) #5 VERTICAL SEE FDN. PLAN FOR LOCATION IF NOTES: FILL LINTEL AND ALL CELLS ABOVE LINTEL. NOTE: FOR BEAM DEPTH 22", PROVIDE A 4" x 4" INSPECTION PORT @ EACH VERTICAL REBAR & DIRECTLY ABOVE THE LINTEL. VERIFY THAT ALL REINFORCEMENT HAS BEEN PLACED PROPERLY. SEE FLOOR PLAN FOR ADDITIONAL INFORMATION. @ OPENINGS LESS THAN OR EQUAL TO 6-0- IN WIDTH DO NOT REQUIRE ADDITIONAL STEEL REINFORCEMENT UNLESS NOTED ON FLOOR PLAN. TYPICAL FILLED LINTEL ASSEMBLY SCALE: N.T.S. WIDTH OF OPENING VARIES 4" FORM CONCRETE INSET TO 112"X9 1/2" PLYWOOD CREATE A SOLID BASE FOR SCRAP MATERIAL BLOCK WALL ABOVE. FORM CREATES CONCRETE RECESS TO 2x4 (NOM.) RECEIVE GARAGE DOOR AND TO ALLOW FOR WATER SHED. KEEP STIFFENER BACK FROM SIDES ENOUGH TO ALLOW SPACE FOR FLAT MASONS TOOLS (THIS IS A RECOMENDATION FOR CONSTRUCTION OF THIS FORM. ANY MATERIAL OR CONSTRUCTION METHOD MAY BE USED PROVIDED END PRODUCT MEETS THE SHAPE AND DIMENSIONS OF THIS DRAWING.) FMOUNTING BASE SHOWN IN POSITION GARAGE ENTRY FORM DETAIL SCALE: N.T.S. -TRACK MOUNTING BRACKET \ GARAGE DOOR TRACK SCALE: N.T.S. POURED CONCRETE BASE FOR BOTTOM OF MOUNTI�NGB BLOCK WALL. RECESSED SPACE TO BE 2" ABOVE FINISHED FOR GARAGE DOOR AND WATER GARAGE FLOOR. SHED FORWARD THIS DRAWING. PARTIAL INTERIOR ELEVATION SCALE: N.T.S. 7 5/8" 8" 75181, 8-1 7 518" 8" A v I 1 1 7. SOLID AREAS ARE 2 — SOLID AREAS ARE STEEL AND GROUT STEEL AND GROUT INTERIOR F1 FULL 8x8xl 6 BLOCK WALL Ct DOOR OPENING DOOR OPENING DOOR OPENING --r. EXTERIOR—/ WALL Ell A 1 ST COARSE 2ND COARSE 3RD COARSE MASON TO LAY BLOCK AS SHOWN ABOVE. EVERY COARSE MUST BE BONDED TO THE COARSEBELOW. EVERY THIRD (3RD) COARSE THE 11" DOORJAMB WALLIS TO BE WOVEN INTO THE MAIN FRONT TO REAR WALL AS SHOWN. MASONRYLAYOUT rD SCALE: N.T.S. � �4 VERTICAL JAM 5/8"DIA. x 8" J-BOLTS AT 6-3/4", 41-3/4", 71", AND 96-3/8" ABOVE GARAGE FLOOR. ALL J-BOLTS WILL BE IN FILLED CELLS (2,000 PSI MIN. CONCRETE), ANCHORS MAY BE COUNTERSUNK (BUT NOT REQUIRED) BOTTOM CHORD OR 2x4 TO PROVIDE A FLUSH MOUNTING SURFACE. HORIZONTAL JAMBS DO rTRUSS BCLOCKING W/ 2-16d TOE NAILS NOT TRANSFER LOAD. a EACH END WALL UJI 0 DOOR STOP MOLDING —2 0 2x TOP PLATE co GARAG 2-16d NAILS @ 24" O.C. OR DOOR EQUAL TO TRUSS BOTTOM CHORD OR BLOCKING 2 x 6 P.T. 2x STUD @ 24" O.C. MAX. PROVIDE P.A.F. NAILS OR 2x P.T. PL.ATE FEQUAL @ 12" O.C. SEE A/S3 FOR STAGGERED FROM BOT. DOOR TRACK PLATE TO CONCRETE REINF. INFO. MOUNTING ANGLE NOTE: REFER TO GARAGE DOOR PRODUCT APPROVAL SHEETS FOR DOOR INSTALLATION INFORMATION PER MANUFACTURER. TYPICAL INTERIOR NON - BEARING WOOD FRAME WALL �j TYPICAL GARAGE DOOR BUCK SCALE: N.T.S. �4 SCALE: N.T.S. � �4 HEADER SUPPORT NO. OF JACKS & STUDS REQ. AT OPENINGS OPENING ')It v A" WALL ^ " 2"x 6" WALL STRAPS JACKS STUDS JACKS STUDS SIZE EA END EA END EA END EA END (1) (2) (1) (2) (1) USP LSTA30 (2) (3) (2) (2) (1) USP LSTA30 (3) (4) (2) (4) (2) USP LSTA30 FLAT STRAPS PER CHART ABOVE TO BE BENT OVER TOP PLATE ** HOLD DOWN CONNECTIONS NOT REQUIRED @ BEARING WALLS NOTED WITHOUT UPLIFT SEE FL OR PLAN NOTES FOR REQUIRED CONNECTION 0 2-ROWS 12d NAILS STAGGERED @ 12" O/C EACH FACE OR 3-ROWS 12d NAILS STAGGERED @ 12" O/C FOR 2"xl 0" OR 2x CRIPPLES @ RE ER HEADER 16" O.C. W1 (2) 12d TOENAILS T/B USP SPT4 w/ (6) 1 Od x 1 Y2" @ 24" \_(2) O.C. 2x HEADER SEE PLAN "'—INTERIOR 1 Od NAILS @ 8" HEADER O/C TYP. BOX HEADER (1) 2x SILL PLATE W/ (2) ONLY 12d TOENAILS. DOUBLE 2x EXTERIOR HEADERS CRIPPLE STUD (1) 2x SILL PLATE W/ (2) "I TYPICAL (U.N.O.) 12d TOENAILS. OPENING LARGER THAN 4 ft (2) 2x SILL PLATE W/ MP3 CLIPS EACH SIDE "',-2x STUDS TYP. USP HTT16 TYP. U.N.O. SEE N/S� HOLD DOWN CONNECTIONS NOT REQUIRED @ BEARING WALLS NOTED WITHOUT UPLIF1 P.T. BOT. PLATE WALL HEADER DETAIL K* Q SCALE: N . T.S. � �4 FFWill','W 14 SPT241 ki LF U STUDS @ " 0 r TRANSOM FRAMING SEE SECTION AA/Sl AND BB/Sl FOR ADDITIONAL DETAILS LINTEL 4 USP P.T. ATE 12 _z(!yTYP.) SEE ELEV. P 7.) PRE-ENGINEERED WOOD TRUSSES @ 24" O/C UPLIFT CONNECTOR (SEE SCHEDULE) DOUBLE 2"x4" S.P.F. TOP PLATE 7/8" STUCCO FINISH PER ASTM C. 926 APPLY 3 LAYERS W1 TOTAL THICKNESS 7/8" OVER METAL LATH. FIRST 2 LAYERS 3/8" THICK EACH. 3RD LAYER 1/8" THICK. ,--CRICKET AS REQUIRED USP SPT24 @ EA. STUD 1/2" EXTERIOR GRADE SHEATHING FASTENED TO TRUSSES WITH 8d COMMON WIRE NAILS @ 4" O/C BOUNDARIES 6" O/C EDGES & 8" BL CKING O/C FIELD 2X4 PT STUDS @ 16" O.C. (2) 2X4 PT STUDS UNDER HIP r= USP HTA20 @ EA. STUD MOISTURE BARRIER 8"X8"X1 6" K.O. BLOCK W/ 1 #5 CONT. AND FILLED W/ GROUT 1 #5 VERT. IN CONC. FILLED CELL--,-------- W/ STD. 90* HOOK IN K.O. BLOCK ALT. KNEEWALL ABOVE MASONRY MAIN SPAN ROOF TRUSS UPLIFT CONNECTOR (SEE SCHEDULE) WALL DETAIL SCALE: N.T.S. PIPE OR DUCT w/ PENETRATION THRU TOP PLATE w/ MORE THAN 50% OF TOP PLATE WIDTH INSTALL SIMPSON PSPN516Z w/ (12) 16d NAILS TOP SPLICE 2 ROWS 1 Od @ 3" O.C. (14 NAILS TOTAL) EA. SIDE OF -f,&. SPLICE STAGGERED 1 Od @ 8" O/C ATTACH ALL ` Q,_1 -1 EXTERIOR STUDS W/ (A) 16d TOENAILS TO76PPLATE NOTE: ST BE BOTTOM SPLIC PLATE LENGTHS MUS OVER STUD AT LEAST 4'-0" LONG, TYPICAL TOP PLATE SPLICE DETAIL M SCALE: N.T.S. �4 F= 2240 LBS USP USP SPT4� SPT241 SP SPT4 — � : , i 2X TOP PLATE --r—, \-X\ OVERLAPPING TRANSOM FRAMING SEE SECTION AA/Sl AND BB/Sl FOR ADDITIONAL DETAILS /RECESS -LINTEL USP SPT241 -NAILED INTO TRANSOM FRAMING USP_ SPT22 LISP SPT4 < 2X8 P.T. BOTTOM PLATE 5/8"x10­J" BOLTS @ 24" O.C. MAX. (MIN. (2) PER BOTTOM PLATE) ROOFTRUSSABOVE /_ 2X BLOCKING INTO ---(2) 16d TOE NAILS TRANSOM 1 Od NAILS @ 6" EA, BLOCKING FRAMING STAGGERED 2X8 WALL ABOVE ENTRY SP SPT22 K.O. BLOCK W/(1) SP SPT4 USP SPT4 BOLTS @ 24" O.C. #5 CONT. & AX FILLED 7 5/8"X1 0" J-BOLTS T- 2X P.T. PLATE @ 2'-0" O.C. MASONRY WALL 2X8 P.T. BOTTOM PrE'_� 5/8"x10" "J" BOLT @ 24"O.C. MAX. (MIN. (2) PER BOTTOM PLATE) C --USP SPT4 1 Od NAILS @ 41, 10d NAILS @ 6"O.C. STAGGERED A STAGGERED TRANSOM FRAMING 0 0 BEYOND. E- LPLYWOOD /—PLYWOOD FASTENED TO TRUSSES lo SHEATHING WITH 8d COMMON WIRE NAILS @ 4" O/C BOUNDARIES 6" O/C EDGES L & 8" O/C FIELD —PLYWOOD I SHEATHING MASONRY -- I -BOLTS @ 24" O.C. WALL BELOW — 0-o 5/8"X10" J SPT4 MAX. (MIN. (2) PER BOTTOM PLATE) ALTERNATE: 5/8" DIA. ATR EPDXIED MIN. 6" INTO BOND BEAM @ 24" O.C. FRAMING DETAILS ABOVE ENTRY rR SCALE: N.T.S. z V) (D Q) (_/�l 4--J Uj r) 0 LU 0 U) U) ce) V) .2o C14 a) 01) LLJ E o 0 0) 01) C M ce) M'O M C1,4 4j (D C LL co 0 Cf I CD -14 < 0 U) CL CD Lo 0 'T a D.— < 0 AI 8 D. N-C B D C r cc 7L24 0 04 z M Ur LL C=1j u1ii L �Ini U] 5q. U ZV r -L < -0 -,Z-. 65 LL11 z To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code 5th Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seaL C) 0 Z 0 �­q :Lj C:) Lf) = > V) C:, V) (0 U) V) Ln L_ LL Ln CL 31 CL 0C, z z �i E z i C:) W u., C:) �.o 0, �R 3r � z z < '8,0, LL, LU Uz< =1 z z L 0 L�u Z fy X _i 0 U) R 0 L,zo 10 kwn z Lr) z z z 0 -0 Lr) cy > z 0 U I C/) ZE :�< ZE M': v I R OZ < �, t-! US F_ LLJ r1j Lu yy z< 0� < r_j IV 0 Lu W x 0. 9 z z LIJ 11714 U1) LU 0. L<) Ce =Z, _j T__I < < z %-10 0 z < LU Z Q� 11�0 (71 Z I 51 < LA z 0 N :5 LU < z W rn T-1 a_ Ln c' SCALE AS NOTED DATE 2/24/2014 TECH: MIAMES VERSION No' 10 SHEET NO. S4 SP HGAM 10 W/ (4)- 14"x1-3/4" WEDGE OLTS & (4) SDS 1/4" 1 1/2" SCREWS SEE STRUCTURAL NOTES AND -� NAILING SCHEDULE FOR SHEATHING DETAIL TOPCHORD— — BLOCKINGFOR�_ X. FIRST FOUR ROWSOF TRUSSES @ EDGESOF 2x4 CROSS BRACE SHEATHING APPROX. 8" FROM TYPICAL @ RIDGE FASTENED AT 48" O.C. EACH JOINT W/ (3) 1 Od MAX. & (2)1 Od TOE NAILS @ EA. END @ 48" O.C. rR TOENAIL W/ (2) 16d NAILS SEE STRUCTURAL NOTES AND 7CKNAIL W/ (2) 16d NAILS 2"x4" OUTLOOKER NAILING SCHEDULE FOR � @ 24" O.C. SHEATHING DETAIL USP RT 16 OR EQUAL @ 7 EA. OUTLOOKER 2'x4l' 7 L OKER x @ 24" O.C. 45* t 24" MAX. TOP CORD BLOCKING 45*t x 2X4 CONT"L" BRACE \-USP RT16 OR FOR FIRST FOUR FASTENED W1 (2) 10d EQUAL @ EA. ROWS OF TRUSSES @ 3"@ 24" O/C. CMID OUTLOOKER EDGES OF HEIGHT "L" BRACE TO EXTEND SHEATHING TYP. 2X4 KICKER X EXTEND @ LEAST 90% OF AT LEAST 90% OF WEB @ V-13" O/C. 2x4CROSSBRACE WEB LENGTH & NOTCH @ LENGTH (SEE TABLE) APPROX. 8" FROM BOTTOM CHORD (SEE 2x6 P.T. LE TRUSS RIDGE FASTENED AT TABLE) SILL 1/2" CDX PLYWOOD OR EACHJOINTW/(2) 10d USP RT3A WITH 8-8d 7/16" OSI3 SHEATHING 7/ FA & (2)1 Od TOE NAILS @ K,\. x FROM LEDGER TP ATTACHED W/ 10d EA. END BLOCKING NAILS @ 6" O.C. EDGES GYP -RUM WALLBOARD GABLE TRUSS AND 12" O.C. FIELD 2"X4" PANEL BLOCKING @ 48" O.C. FOR THE FIRST 1/2" CDX PLYWOOD OR 10dX3" @ 3" O/C THROUGH CHORD INTO 2"x6" P.T. PLATE (4) ROWS OF TRUSSES FROM EA. END TYP. BOTTOM CORD ATTACHED W/ (2) 16-d TOENAILS 2"X4" LEDGER (MATCH BOTTOM CHORD 7/16" OSB SHEATHING ATTACHED W/ 10d NAILS @ 6- O.C. EDGES AND 12" 2X4 "T" ON TOP OF PANEL BLOCKING, WEEP SCREED A. .. SLOPE OF ADJACENT SCISSOR TRUSS) O.C. FIELD X FASTEN WITH 10dx3" @ 4" O/C SPACED INSTALLED PER MANUF. . I 2"x6" P.T. SILL NOTCH 1" BRACE HERE @ 48" O.C. MOISTURE BARRIER 5/8" x 10" "J" BOLT @ 48" O.0 WEEP SCREED 5/8"x 10" "J" BOLT @ 32" O.C. MINIMUM 6" FROM USP HTA20 OR EQ. @ 6-10" O.C, TYPICAL. INSTALLED PER MANUF. PLATE SPLICES W/ 3/16"x2" 0 PLATE WASHER USP HTA20 EA TRUSS ALTERNATE USP LSTA18 STRAIGHT STRAP @ 4'-0" �P@ 0 MOISTURE BARRIER @ , O/C ALIGNED WITH GABLE WEB. ATTACH TO TRUSS VERT. WEB (24- O/C MAX.) Wn-1 0dx1 1/2" AND TO MASONRY W/ (3) 3/16"x 2 1/4" NOTE: IF EMBEDDED TAPCONS. STRAP MISSED VERTICAL SECTION SECTION WEB; USE SCALE: N.T.S. MSTAM36 ON OUTSIDE SCALE: N.T.S. REFER TO DETAIL J SEE STRUCTURAL — ON SHEET S5 FOR NOTES AND NAILING X-BRACING, AND TOP SCHEDULE FOR CHORD BLOCKING INFORMATION 00 ;o SHEATHING DETAIL 1A 2 2"X4" CROSS BRACE WOOD TRUSSES ;0 00 APPROX. 8" FROM RIDGE FASTENED AT 2x4 RAT RUN BRACING EACH JOINT W/ (2) AT 24" O.C. ON TOP OF 10d & (2) 10d TOE BOTT. CHORD FOR 4 NAILS @ EA. END TRUSS SPANS ATTACHED W/ 2 - 16d 2X4 PANEL BLOCKING AT EA. TRUSS JOINT (2) 2" x 4" LAMINATIONS W/ (1) ROW (3) 2" x 4" LAMINATIONS W1 (1) ROW (3) 2" x 6" LAMINATIONS W/ (2) ROWS OF @ 48" O/C FOR THE FIRST (4) ROWS OF 2X4 BLOCKING @ 24" OF STAGGERED 10d COMMON WIRE NAILS OF STAGGERED 30d COMMON WIRE NAILS STAGGERED 30d COMMON WIRE NAILS TRUSSES FROM EA. O/C W/ 2 - 16d (D = 0.148", L = 3") OR EQUAL (D = 0.207", L = 4 1/2") OR EQUAL (D = 0.207", L = 4 1/2") OR EQUAL END TYP. TOP & NOTES: BOTTOM ATTACHED TOENAILS @ EA. END 1) ADJACENT NAILS ARE DRIVEN FROM OPPOSITE SIDES 4) FOR 4-PLY, PROVIDE 1/4" DIA. x 5 1/2" LAG SCREWS OR EQUAL W/ (2) 16-d TOENAILS MASONRY WALL OF THE COLUMN (SPACE AS SHOWN FOR 3-PLY) ARCHITECTURAL FINISH 2) ALL NAILS PENETRATE AT LEAST 3/4 OF THE THICKNESS 5) FOR 5-PLY, PROVIDE 1/4" DIA. x 7" LAG SCREWS OR EQUAL OF THE LAST LAMINATION (SPACE AS SHOWN FOR 3-PLY) 3) EACH 30d COMMON NAIL MAY BE REPLACED W/ (2) 16d 6) REFER TO NDS SECTION 15.3 FOR ADDITIONAL INFORMATION EXT. WALL CONN. @ COMMON NAILS. (ONE INTO EACH OUTSIDE FACE OF NON - LOAD BEARING LOCATION D B.U.C., SAME NUMBER OF ROWS, SAME SPACING) SEE TYP. WALL SECTION FOR SCALE: 3/4" V-0" TYPICAL NAILING SCHEDULES FOR BUILT-UP COLUMNS 8� IN , �5 ADDITIONAL INFORMATION. SCALE: N.T.S. 2"X4" OUTLOOKER @ 24- O.C. W/ (2) 10d PER JOINT IINIMUM 2x :ROSS BRACING PRE-ENGINEERED 3EE PLAN FOR WOOD TRUSSES OCATIONS) 1 Odx3" O/C @ _/ 1 2'X4�' TOENAIL 6" O/C RUNNERS W/ (2) 16d TYPICAL (2) 16d PER NAILS JOINT CONTINUOUS BOTTOM CORD BRACING 2"X4" MIN. SEE M/S5 CROSS BRACING DETAIL rj__� ALTERNATE NON -DROP GABLE END DETAIL SCALE: N.T.S. GABLE TRUSS SS 1" BRACE W/ 1 Od @ 4" O.C. (SEE SCHEDULE FOR SIZE 12 AND LOCATION) 6.9 MAX. 85 S5 .4 11 �11 1. t CONT. BEARING GABLE END BRACING DETAIL MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION SCALE: N.T.S. SCALE: N.T.S. 8d @ 6"O/C WOOD TRUSSES USP HGAM10 W/(4)-3/16-x1-3/4- WEDGE BOLTS & (4) SDS 1/4" x 1 1/2" SCREWS —BACKNAIL W/ (2) 2x4 OUTLOOKER @ 24- O/C TOPCORD BLOCKING FOR USP RT16 OR FIRST FOUR ROWS EQUAL @ EA. OF TRUSSES @ OUTLOOKER 24" MAX. EDGESOF SHEATHING TYP. BRACE TO EXTEND rl" AT LEAST 90% OF WEB LENGTH (SEE TABLE) ABL TR SS /;1/2" CDX PLYWOOD OR 7/16" OSB SHEATHING t ATTACHED W/ 10d NAILS 1 @ 6" O.C. EDGES AND 12" O.C. FIELD (2) 16d NAILS '70N TOP OF PANEL If2X4 BLOCKING, FASTEN WITH 1 0dx311 @ 411 O/C USP HGA10 @ 36 O.C. DBL. TOP STUD WALL PLATE (SEE TYP. SEC.) USP SPT24 @ EACH STUD SECTION 4� SCALE: N.T.S. �5 2 x 4 BLOCKING W/(2) 10d TOE NAILS @ EACH END @ 24" O/C (TYP) \-BRACING W/(3) 1 Od x 3" @ \EACH CONN. @ 24" O/C -MOISTURE BARRIER \-BOND BEAM MASONRY WALL RCHITECTURAL FINISH EXT. WALL CONN. @ NON - LOAD BEARING LOCATION (UNEVEN CLG.) SEE TYP, WALL SECTION FOR ADDITIONAL INFORMATION. SCALE: N.T.S. 1" BRACING REQUIREMENTS STUD SPACING NO 1"BRACE (1) 2"X4" (U.N.O.) 1" BRACE 2"X6" (U.N.O�) 1" BRACE 2411 0-0" - T-O" T-01' - 6-0" 6-0" & GREATER SCISSOR GABLE (1) 2"x8" #2 S.P.F. @ EACH VERTICAL AND (2) 2"x8" FULL HEIGHT @ DIAPHRAGM BLOCKING NOTE: 1) 1" BRACE MUST EXTEND AT LEAST 90% OF WEB LENGTH EXCEPT, SCISSOR GABLE WHICH REQUIRES BRACE TO EXTEND FULL HEIGHT OF GABLE. 2) 1" BRACE TO BE FASTENED TO GABLE STUD WITH 10dx3" NAILS @ 4' O/C. 3) SEE 6/S5 FOR MORE INFO. OVERLAP TRUSS BRACING AT LEAST TWO TRUSS SPACES SEE STRUCTURAL----\ NOTES AND NAILING BACKNAIL W/ (2) 16d NAILS SCHEDULE FOR SHEATHING DETAIL 2x4 OUTLOOKER @ 24" O.C. (OPTIONAL - SEE ELEVATIONS) SEE STRUCTURAL- TOP CORD BLOCkING USP RT1 6 OR EQUAL @ AND AILING FOR FIRST FOUR ROWS 24" MAX. EA. OUTLOOKER SCHEDULE FOR OF TRUSSES @ EDGES SHEATHING DETAIL OF SHEATHING TYPICAL DOUBLE TOP PLATE 2"x4" CROSS BRACE X-811 APPROX. 8" FROM LISP FROM RIDGE FASTENED AT RIDGE FASTENED AT SPT4 @ E EACH JOINT W/ (2) 1 Od & (2) EACH JOINT W/ (2) STUD 10d TOE NAILS @ EA. END 10d & (2) 10d TOE 2X6 FRAMED WALL - SEE NAILS @ EA. END WALL SE CTION FOR SPACING 2x4 PANEL BLOCKING 112" CDX PLYWOOD OR 7/16" @ 48" O/C FOR THE /_OSB SHEATHING ATTACHED FIRST (4) ROWS OF W/ 10d NAILS @ 6- O.C. EDGES TRUSSES FROM EA. - -1 !I I v-;: AND 12" O.C. FIELD END TYP. TOP & I N I !==j 1 DQI 1 1 �, N-1- (2) 16d NAILS BOTTOM ATTACHED CKING W/ (2) 1 -d TOENAILS 2X4 PANEL BLO 2X4 BLOCKING O.C. FOR THE FIRST (4) ROWS OF TRUSSES FROM EA. END 2X4 "T" ON TOP OF PANEL TYP. TOP & BOTTOM ATTACHED BLOCKING, FASTEN WITH W/ (2) 16-d TOENAILS 1 0dx3" @ 4" O/C 2X4 LEDGER (MATCH BOTTOM CHORD SLOPE OF ADJACENT TRUSS) SECTION SCALE: N.T.S. BACKNAIL W/ (2) 2X4 OUTLOOKER F 16d NAILS @ 24" O/C TOP CORD _F BLOCKING FOR USP RT4 6R USP RT16'6R FIRST FOUR ROWS EQUAL @ EA. QUA EA E L@ OF TRUSSES @ OUTLOOKER OUTLOOKER 24" MAX. EDGES OF SHEATHING TYP. 1" BRACE TO EXTEND rAT LEAST 90% OF WEB LENGTH (SEE TABLE) ABL TRUSS 1/2" CDX PLYWOOD OR 7/16" OSI3 SHEATHING ATTACHED (2) 16d NAILS W/ 1 Od NAILS @ 6" O.C. O.C. FIELD JACK TRUSS //,---SEE PLAN FOR 2x4'7 ON TOP OF PANEL--/ BLOCKING, FASTEN WITH L 2X4 BLOCKING W1 FF7 1 Odx3" @ 4" O/C (2)12d TOENAILS 7 1 SECTION 69 SCALE: N.T.S. �5 \-MINIMUM (2) 16d PER JOINT \-MINIMUM 2X4 TRUSS BRACING TRUSS BRACING OVERLAP DETAIL SCALE: N.T.S. 6" OVERLAP 1" BRACE W1 10d @ 4- O/C (SEE SCHEDULE FOR SIZE AND LOCATION) @ EACH STUD GABLE END BRACING DETAIL SCALE: 3/4"=V-0" MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION HIP FRAMING REFERENCE PLAN z LU a. 20'-0" MAX "V 13RACE SEE DET_ J/S5 2x4 BLOCKING 2x4 "T" BLOCKING @ 48" O.C. 16d NAIL 1" BRACE ATTACHED W/ 1 Od NAILS @ 4" O.C. TYPICAL GABLE TRUSS WEB DOUBLE 1" BRACING DETAIL r5 SCALE: N.T.S. 2x4 'T'BLOCKING-1--l- 2x4 BLOCKING @ 48" O.C. "L" BRACE ATTACHED --16d NAIL W/ 10d NAILS @ 4" 0. TYPICAL W GABLE TRUSS WEB --- SINGLE 1" BRACING DETAIL�-_6 SCALE: N.T.S. S5 DIAPHRAGM BLOCKING @ 48" O/C GABLE TRUSS .1 TRUSS VERTICAL (2) 2"x8" 1" BRACE FASTENED WITH (3) 16d PER SIDE SCISSOR GABLE "T" BRACE /'--7 AS PER HIB 91 SCALE: N.T.S. 20'-0" MAX CONTINUOUS BOTTOM CHORD BRACING 2X4 MI N. WIN - lqq M 06, INS OWN INA NOTE: 1) SEE TRUSS MANUFACTURER'S TRUSS ENGINEERING CUT SHEETS FOR ADDITIONAL PERMANENT BRACING THAT MY BE REQUIRED 2) 7' BRACING MAY BE USED IN PLACE OF PERMANENT BRACING PROVIDED IT EXTENDS OVER AT LEAST 90% OF THE WEB. REQUIRED MINIMUM PERMANENT TRUSS BRACING PLAN AS PER BCSI 1-03 SCISSOR TRUSS SCISSOR TRUSS W/ DROP CEILING BRACING DETAIL �7_ /TOP BOTTOM CHORD GABLE END BRACING @ 4'-0" O.C. MAX. FOR FIRST (4) ROWS OF TRUSSES SCALE: N.T.S. 2X4 BRACING @ 48" O.C. CONTINUOUS TO FIXED LOCATION ATTACHED W/ 2-10d @ EA. TRUSS (NOTE: BRACING MAY BE PLACED ON EITHER TOP OR BOTTOM OF THE BOTTOM CORD) DROP CEILING FRAMING MEAN ROOF HEIGHT UP TO 30'-0" SCALE:NTS SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION WOOD FRAMED GABLE END BRACING DETAIL MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES SCALE: N.T.S. FOR WIND SPEED SPECIFICATION CD !;2 Z < V) Q) LU U 0 W Ln CL� E 0 :D W v) Ce) Ln r 0 LU 04 CD cl) cl) C: M cl) NOMINk E 0 a TV M � CIJ 0 0 u 0 J-_ U_ 00 0 6!� a) a) U) _�d r- ao LO 0 v 0 < 0) A 1 N C-B D C 'V a �&.. tr 4 co f- &I A z 2 'r C11.) 5 --. . 5 , I .2 CO-X M V 11-zollu-i W 3, n LU 0 EL ­5 05 kl 0, 2 z IL LL1 lay `r 116 URI M1, To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code 5th Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portion, of the drawing pages bearing Engineer's signature and sea]. C:) C:) Z C-4 0 (v r-� 4-J > U.) P-4 z4.1. V) M Lr) -.2 Ln v- U_ ru ce U a 00 z < z E z LU C:) _j 0 W 9.0 11 0, uj zg z au, QW= Uz< =) :z (D 0 LU Z 2 2 � L4 8 gg 2 0 Co @ 8 z Ln co _j �� zz H z 0 _0 5 a- "A: LLJ 0 > U z>g U21: 0 3 P r- 5 <� he r- x '06 i C-4 .0, r*s LL z < v- C"j -: Z Z r-j -0 ce z " LU Ln LLJ 2: di < z =5 �j 0� Z, � 0 �z Q0 all Inn z I 0� (Y < Ln V) 0 Z L=U z z Lu rn T­1 10- SCALE AS NOTED DATE 2/24/2014 TECH: MJAMES VERSION NO' 10 SHEET NO. S5 LU (1) LAYER TYPE 11 (#30) UNDERLAYMENT FOR ROOF PITCH >4:12 (2) LAYERS TYPE I OR TYPE 11 (#15 OR #30) UNDERLAYMENT FOR ROOF PITCH 4:12 OR LESS. 12 PRE ENGINEERED WOOD TRUSS @ 24- HURRICANE ANCHOR @ EACH TRUSS O.C. MAX. SHINGLE ROO FOR UNDERLAYMENT HINGLE ROOF REQUIREMENTS SEE R905. INSULATION — BAFFLE 15132" CDX PLYWOOD OR 7/16" O.S.B. (SEE ROOF NAILING INSULATION P SCHEDULE ON SHT SN1) CHART ON FLOOR PLAN LUMINUM DRIP EDGE ALUMINUM FASCIA 5/8"OR 1/2"HIGH STRENGTH CEILING 2x SUB FASCIA BOARD PER CODE W1 13/8" DRYWALL SEE SOFFIT SHEET NAILS OR DRYWALL SCREWS 7" O/C CEILING & 8" O/C WALLS ATTACHED WALL SHEATHING TO (2) TOP PLATE W/ 8d @ 4' 1/2" GYP WB O.C., 2 ROWS DOUBLE 2X S.P.F. TOP PLATE 1X2 NAILER PLYWOOD SHEATHING 2X BLOCKING @ EA. WALL NAILED PER NAILING SCHEDULE SEE DETAIL C/S6 SHEATHING JOINT FOR MORE INFO LU 0 W 16" O.C. 2X S.P.F. STUDS 0 = W1 (4) 16d TOENAILS TO TOP PLATE 0 (n 7/8"CEMENTITIOUS FINISH PER ASTM C. 926 APPLY 3 LAYERS W1 TOTAL THICKNESS 7/8" OVER 2x BOT. PLATE W/ (2) 1 Od @ 6" O.C. METAL LATH. FIRST 2 LAYERS 3/8" THICK EACH. 3RD 3/4" PLYWOOD DECKING GLUED AND NAILED W/ 10d J LU = W LAYER 1/8" THICK. COMMON @ 6" O/C EDGES AND 12" O.C. FIELD U_ = INSULATION PER 1/2" GYP. WB OR 3/8" PLYWOOD/ TYPE 2-M-W OSB CHART ON FLOOR PLAN (DRAFTSTOPPING) TO BE NAILED W/8d COMMON @ 6- O/C TOONE SIDE OF THE FLOOR TRUSS FORAN AREA 1000SG. B R <-FT. OF FLOOR AREA & SEALED PENATRATION AREA W1 FOAM. DRAFTSTOPPING SHALL DIVIDE THE CONICEA�� S6 S6 SPACE INTO APPROX. EQUAL AREAS. FLOOR SYSTEM ETALSEAT ERP N OR FELT PAPER FOR MOISTURE BARRIER 1/2" HIGH STRENGTH OR 5/8" GYP WB (OR 5/8" GYP. TYPE " X' @ GARAGE ONLY) W/ 13/8' DRYWALL NAILS OR DRYWALL SCREWS 7" O/C CEILING & 8'O/C WALLS STD. 90 HOOK (SEE DETAIL) 1/2" GYP WB 8"x8"X16" CONC. KNOCKOUT INSTALLATION PER BLK. W11#5 ROD CONT. FILLED CHART ON FLOOR PLAN SOLID W/GROUT NOTE: LAP SHEATHING TO BOTTOM OF BAND JOIST TYPICAL ARCHITECTURAL 19 ,�FINISH (1) #5 VERT. IN FILL CELLS (SEE FOUNDATION PLAN & NOTES) U) 4"A" INSPECTION PORT AT U_ - cr _j a- EACH FILL CELL TYPICAL LU (0 1x WD FURRING @ 24" O.0 AT GARAGE CONTRACTOR BASEBOARD LO TO CUT BLOCK OR POUR C14 PSI CONC. SLAB CURB DUE TO SLOPE MIN. 2500 MIN. PSI MAY VARY PER NOTE: EXTEND DECO FINISH MUNICIPALITY 410 6" BELOW GRADE '911 A 4* 4 /FINISH GRADE -4 00 dd - A. T 6x6 W1.4xW1. .. LL =1 1- 99 WWF OR FIB MESH A STD. 90 (3) # 5 REBAR ON 3" CHAIR' (SEE DETAIL) W/3" MIN. CLEARANCE TYP 2-STORY WALL SECTION SCALE: 3/4"=V-0" U SP LSTA24 STRAP W/ 8-1 Od x 11/2" NAI LS TO STUD 2ND FLOOR FRAME CONNECTION SEEJ /S-6 FOR ADDITIONAL INFORMATION. USP LSTA24 STRAP W1 8-10d x 1-11 NAILS TO STUD & 8-10d x 1-1/2" TO BAND JOIST @ EA. STUD 2nd FLOOR WALL---,- BAND JOIST I ----------- �k 'USP MP4F @ 24" D.C. w/ 12-8d NAILS , I ) 1st FLOOR WALL USP LSTA24 STRAP W/ 8-1 Od x 1 1/2" NAILS TO STUD & 8-1 Od x 1 1/2" TO BAND JOIST @ EA. STUD 2ND FLOOR FRAME CONNECTION @ WOOD 1 ST FLR. UPLIFT CAP = 928 PLF SHEAR CAP = 355 PLF SEE J/S6 FOR ADDITIONAL INFORMATION. TX4" PANEL BLOCKING @ 48" O/C FOR THE FIRST 8'-0" OF END WALL FROM EA. END. (TYP.) TOP & SCALE: N.T.S SCALE: N.T.S. FEND SHEATHING TO )F BEAM OR GIRDER LTE W1 O.C. )OR TRUSSMOIST 2"x BOT. PLATE W/ (2) 1 Od @ 6" O.C. NOTES: * USE MP4F & EXTEND SHEATHING TO BOTTOM OF RIM BOARD/BAND JOIST FOR SHEAR WALL ONLY, SPACER BLOCKS E S6 "T" CORNER TYPICAL 'IT" AND CORNER DETAILS rN SCALE: N.T.S. � �6 BOTTOM CHORD ATTACHED W/ (2) 2ND FLOOR FRAMING SEE 16d TOE NAILS SECTION J/S6 DECKING ATTACHED WALL SHEATHING TO BOTTOM PLATE/CHORD W/ 8d @ 4" O/C, 2 ROWS STAGGERED FLOOR TRUSS SEE FRAMING PLAN FLOOR TRUSS SEE FRAMING WEEP SCREED PLAN INSTALLED PER MANUF. 2"X4" CROSS BRA CE @ 48" USP HTA20 @ 24" O.C. W/ O/C FOR THE 1 ST 7-0" OF 10-1 Od X 11/2" NAILS INTO END WALL W1 (2)10dxT @ E BLOCKING TRUSS & MIN. 4" END INTO TX4" BLOCKING EMBEDMENT IN CONC. 2ND FLOOR FRAME CONNECTION R PARALLEL TO MASONRY WALL SCALE: 3/4"=V-0" SEE TYP. 2-STORY WALL SECTION FOR ADDITIONAL INFORMATION. 2x STUDS @ 16" O.C. (2) 1 Od @ 6" O.C. 2"x BOT. PLATE W/ PRE-ENGINEERED FLOOR TRUSSES FLOOR CONNECTION @ MASONRY 1ST FLR. SEE J/S6 FOR ADDITIONAL INFORMATION. CONTINUOUS TO BOTTOM RIBBON ATTACHED WALL SHEATHING W/ 8d @ 4" O.C., 2 ROWS STAGGERED 2X4 RIBBONS, EACH W/ 4-16d NAILS INTO EA. FLOOR TRUSS WEEP SCREED INSTALLED PER, MANUF. -USP HTA20 @ EA. TRUSS W/ 10 - 10d x 1 1/2" NAILS INTO FLOOR TRUSS & MIN. 4" EMBEDMENT IN KO BLOCK SCALE: 3/4"=1'_0 RIBBONS DETAIL (FLOOR TRUSS) O� SCALE: 1 1/2"=V-0" NOTE: SEE TYPICAL WALL SECTION "/,,--SEE SHEATHING SPECS ON FLOOR C/S3 FOR ADDITIONAL INFORMATION 1/2' GYP W.B. MIN.@ GARAGE SIDE IF APPLICABLE (1) ROW OF 2X BLOCKING @ MID HGT. FOR WALL HGT. < V-15". (2) 5/8"DIA. x 10" "J" BOLT W/ 8" ROWS OF 2X BLOCKING @ 3rd FITS EMBEDMENT @ 24" O.C. W/ FOR WALL HGT. > 81-611 2"DIA.X 3116" PLATE WASHER USP SPT22 @ EA. STUD (MIN. SHEAR 3500#. MIN. TYPICAL 2 x STUDS @ 16" O.C. 1 TENSION 2600#.) 2X P.T. PLATE 6 x 6 W1.4 x W1.4 WWF OR FIBERMESH A 4. . A -4 I :L.'T CLEARANCE (3) #5 CONT. ON 3" 7 17—T III I CHAIR W/ 3" MIN. INTERIOR 2-STORY FRAME SECTION SEE TYP. 2-STORY WALL SECTION FOR SCALE: 3/4"=V-0" ��S16 ADDITIONAL SLAB INFORMATION. 15/32"OSB EXPOSURE1 SHEATHING PROVIDE BLOCKING ii REQUIRED I SECTION X- NOT FULL HEIGHT SHI (2)- 2x TOP PLATE BEYOND =-15/32"OSB EXPOSURE1 SHEATHING LLI Lu --SOLID 2X C 1 BLOCKING @ FOPENING C @11 0 SHEATHING W EDGES(SEE I I I SECTION X-X) I = - CL 0 - x Lu X --- -2x STUDS LUUJ BEYOND. (n SEE PLAN 0 1111U'1�� I I --- I I I "',-2x4 P.T. BASE PLATE BEYOND 2x RIBBON ORJ' VERTICAL \--&-JHORIZONTAL SEE PLAN BLOCKING BETWEEN FLOOR WALL SHEATHING SYSTEM WALL ELEVATION DIAGRAM 4 FT. 4 FT. 2 2 5 FT. 4 FT. 4) 5 FT. 4 FT. 2 FT. 4 FT. 4 FT. 2x CRIPPLES @ 16" O.C. W/ (2) 12d TOENAILS T/B 10d NAILS @ 81, O/C TYP. DOUBLE 2x CRIPPLE STUD TYPICAL (U.N.O.) ROOF NAILING ZONE DIAGRAM ROOF NAILING SCHEDULE NAILING ZONES (SHINGLE ANDTILE) 0 Lu ZONE 1: 8d RING SHANK NAILS @ 6"O.C. ON EDGE AND 6"0.0 IN FIELD ZONE 2:8d RING SHANK NAILS @ V'O.C. ON EDGE AND 6"O.0 IN FIELD ZONE 3 8d RING SHANK NAILS @ 4- O.C. ON EDGE AND 4' O.0 IN FIELD 7 Z (NOTE: IF 5/8"PLYWOOD IS USED, CONTRACTOR MUST USE 10d RING LL X 0 SHANK NAILS) NOTE: ROOF SHEATHING: (APA RATED EXPOSURE 1) 1/2"PLYWOOD 191 (TILE) OR 7/16' OSS MIN. (SHINGLES) SPAN RATED 24/16 0 r8ff SHEATHING MAY BE INSTALLED VERTICALLY OR HORIZONTALLY, ATTACH 0 ca 0 on _j D PER NAILING SCHEDULE. PANEL EDGES WILL NEED TO BE ATTACHED TO P r I z LL STUD AND OR BLOCKING AT ALL EDGES. (N uj 00 1: X U. LL A MINIMUM 118"SPACE IS RECOMMENDED BETWEEN PANELS AT EDGES AND END JOINTS TO ALLOW FOR EXPANSIONS FASTENERS SHALL NOT t. PENETRATE SURFACE MORE THAN 1/8" 3/8" "S" = NAIL 3/8' SPACING 3/4" 1/2" S S 1/2" S (Z) NAILAT BASE 2 ROWS@ 4" O.C. W/8d COMMON NAIL NAIL AT TOP PLATE TWO ROWS @ 4' O.C. W/8d COMMON NAIL @ NAIL OPENING PERIMETER @ 3' O.C. W/8cl COMMON NAIL @ NAIL INT, AT 3" O.C. W/8d COMMON NAIL STAGGER ALL VERT. JOINTS & NAIL @ 4- O.C. W18d COMMON NAIL SHEATHING SPLICES @ HEADER - NAIL SHEATHING TO HEADER W1 8d COMMON NAILS @ 4- O.C. (2) 8d NAILS @ 3" O.Q TO EACH TRUSS END OR @ VERTICAL @ MEMBER IF GABLE END [NO T E: 8d NAILS FOR WALL SHEATHING MUST BE MIN.131" X2112' SURFACE MORE THAN 118". Do NOT OVERDRIVE NAILS, FASTENERS SHALL NOT PENETRATE AT ALL PANEL BLOCKING LOCATIONS MIN 2 X 4 #2 SPF TURNED VERTICAL W/ 7/16" OSB FLITCH PLATE TO W1 (2) 12d TOENAILS EA- END. NAIL FLITCH PLATE TO VERTICAL W1 (4) Scl NAILS (2 8d NAILS 3' O.C. WALL SHEATHING INSTALL. & NAILING SCHED. 2-ROWS 12d NAILS STAGGERED @ FIT O/C EACH FACE OR 3-ROWS 12d NAILS STAGGERED@ 12" O/C FOR 4 2"x`10" OR GREATER HEADER SEE FLOOR PLAN NOTES FOR I REQUIRED CONNECTION (2) 2x HEADER SEE PLAN `—INTERIOR HEADER BOX HEADER (1) 2x SILL PLATE W/ (2) ONLY 12d TOENAILS. EXTERIOR HEADERS (1) 2x SILL PLATE W/ (2) 12d TOENAILS. OPENING LARGER THAN 4 ft (2) 2x SILL PLATE W/ MP3 CLIPS EACH SIDE 2x STUDS TYP. P.T. BOT. PLATE FLOOR TRUSS / SEE PLAN FOR REQUIRED CONNECTIONS LOAD BEAR I NG/EXTERIOR FRAME WALL HEADER DETAIL (2) ROWS OF 2x BLOCKING @ THIRD POINTS 5/8"DIA. x 10" "J" BOLT W/ 8" EMBEDMENT @ 24" O.C. W/ TDIA.X 3/16" PLATE WASHER (MIN. SHEAR 3500#. MIN. TYPICAL TENSION 2600#.) MIN. 2500 PSI CONCRETE SLAB W/ 6X6 W1.4XW1.4 WWF OR FIBERMESH 4A 4 A' M I Mi I A' A (3) # 5 REBAR ON 3- CHAIR 4- W/3" MIN. CLEARANCE ALTERNATE FOOTING SECTION X-X HEADER SUPPORT NO. OF JACKS & STUDS REQ. AT OPENINGS OPENING 2"x4"WALL 2"x 6" WALL STRAPS JACKS STUDS JACKS STUDS SIZE EA END EA END EA END EA END 1-4 (1) (2) (1) (2) (1) USP LSTA30 4-4 (2) (3) (2) (2) (1) USP LSTA30 r79'--16' 1 (3) (3) (2) (3) 1 (2) USP LSTA30 PLYWOOD SHEATHING NAILED PER NAILING SCHEDULE SEE DETAIL C/S6 FOR MORE INFO -2X STUDS @ 16- O/C TUCCO FINISH PER ASTM C. 926 -7/81' S APPLY 3 LAYERS W/ TOTAL THICKNESS 7/8" OVER METAL LATH. FIRST 2 LAYERS 3/8" THICK EACH. 3RD LAYER 1/8"THICK. -USP SPT22 @ EA. STUD _2X P.T. PLATE WEEP SCREED INSTALLED PER. MANUR 210 FINISH GRADE OP 9 @ WOOD 1 ST FLR. SEE J/S6 SCALE: 3/4"=V-0" FOR ADDITIONAL INFORMATION. L z (0 < CL_ Q) a) 4--J uj (Z C-) U 0 L� V) E 0 U) c) V) F_ .20 CO r- U LLJ C14 a) 00 CM Cl) a co cl) E 0 q T �2 co 0 C'4 0 a) C) U) r- 00 -5 00 , c1l of 4) c 0 < M 0 Lo 0 "r CL < RD. ICBDC cc M C5 9A z ow co _j ta. M6 W 4W f W LU (D �e, -o� Uj a, w-, v. ,< H�5 z E '.- S �& 4 LL .0,9 -0- U1 C3 T the best of the Engineer's knowledge, m'AMa1t'1o'n:and beolief, the structural plans and specifications contained within these drawings comply with the Florida Building Code Sth Edition (2014) Residential, Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. I C:) C:) 0 0) N 1--A 4-J C:) (/) '5 C:) > (n 4-J < (n M LO 5' 0 a) Lr) LL rn al� U CL 00 < z E M z LU F- _j C:) W I'D v. 01 -rg >_ 17 z 22 8 0 W L) u, zz 0 W .0 C9 z cl) z z 0 U iz Ln _j z 0 -0 4 2: fu L_ Lij 0 2: > rsj 0 0 z 0 U 0 z M LU U_ ILI R ZO - r LL. 10� -, . -, U4 < U1 - < Z,,< 3: wo W W I.- Z n z z r%j ogw D � 2 Z,-) LU L0 <W z z § CZ8 0 LU he 0� 8 z t < o' D z CY 'A z M 0 -, r z :5 Uj x: �2 z Uj r V) S LE AS NOTED DATE 2/24/2014 TECH: MIAMES VERSION No. 10 SHEET NO. S6 ALL STAIR STRINGERS AND TREADS TO BE #2 SYP (MIN.) THREADS, RISERS, AND 3/4" PLYWOOD NOT SHOWN IN DETAIL FOR CLARITY ALL WOOD TO WOOD CONNECTIONS TO BE GLUED (PL 200) AND NAILED (MIN. (2)16d). 13/4 x 11- JVL 2x4 UNDER STRINGER - GLUED AND NAILED TO LANDING 2X4 UNDER STRINGER GLUED AND NAILED TO LANDING BLOCKING D 2X4 PT NOTC INTO STRINGER L I,---2X8 BLOCKING FOR STRAP Z - I I I I - M _�IX4 bloCking m I � I nAP NAILED TO RISER AND THEN WRAPPED AROUND STUD (USP MTW12) PLAN VIEW SCALE.T"=V-5� NOTE: THESE DETAILS ARE NOT PLAN SPECIFIC. THEY ARE PROVIDED TO YOU AS A STANDARD TO CONSTRUCT STAIRS. REFER TO PLAN DETAILS FOR RISE AND RUN INFORMATION. 3/4" RISER CUT TO FIT MAINTAIN BETWEEN T' AND �'GAP TOP AND BOTTOM, GLUED AND NAILED TO STRINGER 2x1 2 TREAD GLUED AND NAILED 2X4 PT NOTCHED INTO STRINGER AND TAPCONED INTO FLOOR WITH GLUE -AT STRINGER CONTACT POINTS 2X4 SPF NOSING GLUED AND NAILED MATCH NOSING ON OTHER TREADS '�-2x8 SYP DRYWALL STOP MUST �/NOT TOUCH STRINGERS 2X4 BLOCK IN KNEEWALL FOR 2X12 NAILING IX4 GLUED AND NAILED TO STRINGER FOR DRYWALL SPACING SECTION VIEW SCALE: 1'-0" SCAB 2x4 GLUED AND NAILED (EACH 2x12 SYP SIDE) TO BOTTOM EDGE OF 2x12 ALIGN THIS STUD WITH 3/4" RISER CUT TO FIT STRINGER STRINGER FACE OF 2ND RISER MAINTAIN BETWEEN A AND "' GAP TOP AND I'll BOTTOM, GLUED AND STRINGER MUST MAKE FUL NAILED TO STRINGER 2x4 BEHIND RISER CONTACT WITH LAN DING 77c\ BLOCKING FOR 1x4 GLUED AND NAILED TO STRINGER STRAP GLUED TO 2x4 DRAFT RISER AND TREAD 2 FLOOR STOP JOIST x8 SYP DRYWALL STOP MUST NOT TOUCH STRINGERS Nh 777777777/ F/77777 SYP 2X8 SYP 2x8 SYP PT NOTCHED INTO STRINGER - D NAILED TO FLOOR WITH GLUE STRINGER CONTACT POINTS 2x4 CUT DOES NOT BEAR IN WALL GLUED TO 2x8 F SECTION VIEW "All SCALE: 1 V-0" STRINGER MUST MAKE FULL CONTACT WITH LANDING E 2X4 PT NOTCHED INTO STRINGER < AND NAILED TO FLOOR WITH GLU I I I AT STRINGER CONTACT POINTS DOES NOT B 2X4 CUT ON BEVEL - EAR I N WALL SECTION VIEW "D SCALE: 1 V-0" FILLER STRIPS ADDED 'PLYWOOD GLUED & SCREWED TO 4 PLYWOOD DECKING PC X-2x SYP CUT TO FIT BEARS IN WALL ___2xl2 SYP B BEARS IN WALL BULLNOSE DETAIL SCALE: 1 V-0" NGER 3LUED NAILED SECTION D-D SCALE: 1"= V-0" -3/4 PLYWOOD ON DECK __2x8 SYP GLUED AND NAILED TO FRAMING 2X4 DRAFT 2x12 STOP TREAD GLUED AND 2X4 PT NOTCHED INTO STRINGER AND TAPCONED INTO FLOOR WITH GLUE -AT STRINGER CONTACT POINTS H H BLOCKINP FOR SID 11 10 x8 SYP DRYWALL STOP MUST NOT TOUCH STRINGERS GLUED AND NAILED TO STRINGER OR DRYWALL SPACING 2x4 SYP BLOCKING FOR STRAP (USP MTW12) BEHIND RISER SECTION VIEW 111311 SCALE: 1 V-0" -ALIGN THIS STUD WITH FACE OF 2nd RISER 2X4 SYP BLOCKING STRAP(Uq MTW12) SECTION VIEW "Ell SCALE: 1 V-0" E SECTION VIEW SCALE: F0,; -3/4 PLYA ON DECH —2x8 SYF AND N� FRAMIIS -2x4 DRAF" STOP 2X4 BLOCP BLOCKING FOR 2x12 PT UNDER 2x12 C ATTACH ALL COMPONENTS I W/.'"x OF STAIR TO CONC- 4 2 T'TAPCONS @ MAX. 32" O.C. - 1X4 GLUED AND NAILED TO STRINGER 2x4 DRAFT STOP -2x8 SYP DRYWALL STOP MUSTNOTTOUCH STRINGERS L--2x4 BLOCKING FOR 2X12 2x4 PT UNDER 2x12 2X4 CUT ON BEVEL GLUED - AND NAILED TO LVL ---PROVIDE MOISTURE PROTECTION ATTACH ALL COMPONENTS OF STAIR TO CONC. W/ T'X 2 t'TAPCONS @ MAX. 32" O.C. _1x4 GLUED AND NAILED TO STRINGER 11CIII SECTION VIEW SCALE: 1"= 11-01, TOP OF /-STRINGER CONN. TO BOTTOM NEWEL POST LET INTO OF NEWEL POST THE BLOCK PER CONTRACTOR PROVIDE zz� BLOCKING __-�2X8 BLOCKING FOR NEWEL POST TO ANCHOR TO. I nr),; PROVIDE SOLID BLOCKING (GLUED AND NAILEDI FLOOR GIRDER BELOW ALL NEWEL POST OR 1 x 16" VL FROM JOIST TO JOIST. USE 2 X 12 BLOCKS, GLUED AND FLOOR NAILED TO JOIST. TRUSSES NEWEL POST SECTION VIEW "G bL ll SCALE: 1 V-0" OCKING SCALE: 1 V-0" 0 1 /Alrx koUINO I MUk.# I IUIN UE I /AILO (IF 1 1X1 7 REDUCE SCALE.5) SCALE: AS NOTED JOINT . TO )ISTS) NAILED AND TOP PLATE qTO RIM BAND, ID NAILED TO NALL BELOW JOINT -TO )ISTS) 2X USP ECTION VIEW 111-Ill SCALE: 1 V-0"' < __j U) z V) (D Q) U 0 U_j �e 1- E V) �_ 0 W 'm CD LU E 0 N (u co 0) CQ C C', C', 2:2 M 0 (D ely a) -r- E 00 *5 j !� 0 c T -.e U) CL 0 LO 0 -,t < 0 CM a 0. < A I 0 D. N-C-B D-C CO r- U) z z M Z� :9 2 .�< =Lj__ ` " - C11 W W eb I J �vj - a? a- 9d �Rt — z 2q-.9 Ac). E. Z 01 2 IL �, �1.2 12 lic; 7-2 W %"�j V IS, To the bes belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code Sth Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. C:) 0 Z r'j 0 a) N 1­4 4-j C:) U0 'S ;,0 > U.) rt) C:) C:) f0 Lr) < z L a) Ln L 0. LL Q� U z 0-00 < %­00 E z LU C) _j C) W t.0 zz g -< <z O'� WL 8,0, '. 0<� UZ =) z Z a z W� 0 10 2 0 @ z 8 Ln C n z z 0 Uj > A 0 U ur) 5 LU 8 < < U, 5 LL_ P 0 <!Z< -. g < u<1 �1: z 0 1 -0� z 71 =0, W Zz. " LU _j Lr) ?--I 1 1 Llj 3 I<D 28Z8 LLJ < 0 Uj t.0 z 8 z <� v--4 z Z t M cy;� V1 Z 0 0 LU z LU SCALE AS NOTED DATE 2/24/2014 TECH: MIAMES VERSION NO 10 SHEE­r NO. ST 1X4 1/2" DRYWALL DOOR JAMB (REFER 1X4 112" DRYWALL DOOR JAMB (REFER F_1X4 F 1/2" DRYWALL E UNACCEPTABLE INSTALLTION DOOR JAMB (REFER TO SHT. SDW2-K1 P.T. TO SHT. SDW2-K1 TO SHT. SDW2-K1 FOR CONN, DETAILS MAX. 8" PROPER INSTALLATION DO NOT DO THIS 2"x BOT. PLATE W1 (2) 1 Od @ 6" O.C. FOR CONN. DETAILS FOR CONN. DETAILS X 4 ID X 4 #5 REBAR (TYP,) 3/4"PLYWOOD DECKING GLUED ATTACHED WALL SHEATHING TO PLATE W1 IL7 -1 X 4 3-1/4" LONG X 3/16"0 FURRING 3/16"0 X 3" LONG FURRING 3/16"0 X 3-1/2" LONG FURRING V8 400 #5 REBAR AND NAILED W/ 8d COMMON @ 6" O.C. EDGES AND 12" O.C. FIELD I 2X BOTTOM 8d @ 4" O.C., 2 ROWS STAGGERED TAPCON. INTO TAPCONS STAGGERED @ 16- TAPCONS STAGGERED 2X8 (TYPj 000 BLOCK@ SPACING 1 "DETAIL O.C. 2-ROWS INTO 1X8 P.T. STAGGERED @ 16" 0. r, 2-ROWS INTO JE y5z 1X8 4 2x BAND JOISTW/ FACE NAIL 10d PER MANUFACTURE MASONRYTHROUGH 1-1/21' DETAIL- MASONRYTHROUGH 311 DETAIL 4%IIl 90- HOOK (TYP.) STD. 90A # @ TOP & BTTM CHORD, AND (8) 1 x4 P.T. & 1 x8 P.T. 1x8 P.T. & 2x8 P.T. FILL SOLID BOTH CELLS HOOK (TYP.) FACE NAILS 10d @ TRUSS VERT. WEB 3/16" x 3 -1/2" TA TAPCON @ 16" P CO N J Lj1 L fB METAL SEAT PLATE 1 X4 P.T. NOTE: NC 0 4 FR O.C. & 4" FROM C 3/16" x 3 -11211 DOOR JAMB (REFER 1X4 DRYWALL I' j LAP SHEATHING TO LA EACH E EACH END W/ MIN ND VV 2., E DOOR JAMB (REFER 2" EDGE DIST. DGE DISI 1 K FOR DOOR JAMB (REFER TAPCON TO SHT. SDW2-Kl FOR I TO SHT. SDW2-K1 CONN. DETAIL F1/2" :JL _ . ' � 4441# C1 BOTTOM OF BAND TO SHT. SDW2-K1 ### JOIST TYPICAL FOR CONN. DETAILS , FOR CONN. DETAILS 10d @ 12" O.0 C 2A 1X4 E ; N '0 FURRING _j 2X8 P.T. WITH 3/1613 X 3" 3116 " X, L OT 12d. III N FIRST COURSE USP HGAM10 @ 12" O.C. w/4-SDS Ax 1/ LONG TAPCONS T r:r 2x P.T. AS REQ'D 2X8 P.T.. STAGGERED @ 16" O.C. 2X8 41% �_NOTCHWEBATTHE JOIST & (4) 3/16"x1-3/4" WEDGE INTO K.O. BLOCK 2x,DETAIL 2 1/4" DETAIL 2-ROWS INTO MASONRY 3-1/411 DETAIL ±5A FIRST 2 COURSES BOLTS BUILDOUT OVER SIZE DOOR -WINDOW ROUGH OPENINGSKC�_C� FILLED CELL PER FOUNDATION PLAN FILLED CELL INSTALLATION KH RETROFIT FOR MISSING EMBEDDED STRAP SCALE: N.T.S. � �s SEE TYP. 2-STORY WALL SECTION FOR ADDL. INFO SCALE: N.T.S. SCALE: N.T.S. � �s 2x8 P.T. BUCK -CONNECT TO BLOCK SECTION UPLIFT CAPACITY = 945 # FOR 1 STRAP W/ 1/4" x 3 1/4" TAPCON (1 1/4" MIN. A -A = 1890 # FOR 2 STRAPS /-FILL 1St4 COURSES EMBEDMENT INTO BLK.) 1/4" MAX SOLID WIGROUT 2- 8" I -PLY PRE-ENGINEERED TRUSS 1 X 4 FURRING SOLID BLKG. AT TOP BTWN. 1/4" x 3 1/4" TAPCONS 1" BLOCK HEADER ARCH BLKG. & BUCK USP RT16M W/ (8) NA1 1 NAILS & (6) 4 x 21" . . . . rAPCONS 1/2" DRYWALL . . 1 Od NAILS x *NAILS AND 8d NAILS AT 8" O.C. AT BUCK 2 x 8 45^ DIAGONAL —LEAVE A CUT OUT IN O.S.B. ON THE X 1 t'WEDGE BOLTS (1) ST P 1225 (4) RA (4) 10d NAILS INTO BRACE(S) 2 x 8 BRACE/ BLKG. INSIDE TO ALLOW FOR INSULATION (2) STRAPS 2450#]) 7/16" OSB TO BE INSTALLED BOND BEAM OR CAST FOR OVERHANGS BETWEEN OVER 11/2" BUILT UP PLWD. BUCK ARCH PANEL CUT HOLE IN O.S.B. FOR POLY -CELL IN THIS AREA ---2 x 8 45 DIAGONAL BRACE AT EA. IN PLACE BEAM CONTACT ENGINEER OF RECORD FOR FURTHER INSTRUCTIONS. SCRIBE (NOTCH) BACKSIDE TO FIT ARCH (4) 10d NAILS INTO 2 x 8 FACE OF ARCH W1 (3) 10d NAILS AT EA. END RETROFIT TRUSS DETAIL OVERHANG" CONNECT W/ 8d NAILS BRACE/ BLKG. \—PROVIDE N.T.S. INSTALL WDW. SCREW ANCHOR--/ ­2 x 4 SOLID BLKG. (FULL WIDTH OF WALL) BTWN. OSB INTO ARCH BLKG. PER ARCH FACES W (4) 10d NAILS THRU OSB INTO 2 x 8 TAPCON WITHIN RETROFIT WALL OVERHANG DETAIL (NTS) INSTALLATION DETAILS A -A PROVIDE TAPCON PER WDW. INSTALLATION DETAILS OR THRU --\'N 4" MIN, OF BRACE 2 X 4 #2 SYP SCAB TO SIDE OF TRUSS AS SHOWN FOR O.H. UP TO 2'-6" FOR OVERHANGS BETWEEN 3/4" TO 11/2" 1-1/2" THK. OR MORE BUCK WITHIN 6" MIN. OF START OF ARCH 2X6 SYP #2 CONT. (MATCH TRUSS DEPTH DOUBLE 2x4 SCAB FOR Z-13" TO 4'-0" O.H. START OF ARC IF TRUSSES USED) W/ (3) #6 X 4YP WOOD NOTE: FOR OVERHANGS LESS THAN 3/4"- NO REPAIR RECI'D. ARCH DETAIL 4'MAX. RAD. SCREWS @ 16" O.C. MAX. OR IF MASONRY WALL USE 1/4" X 3 1/2" TAPCONS AT 16" (2) 10d NAILS @ 8" O.C. TO TRUSS TOP CHORD (3) SCALE: N.T.S. SS O.C. 12 + + + PLYWOOD SHEATHING 11-011 51-011 L JACK TRUSS PROVIDED BY SEE + + TRUSS COMPANY OR PLAN 2x6 #2 SYP @ 24" O.C. (A�/ + + + + INISH FLOQ I 2 x 8 BUCK - CONNECT TO BLOCK SECTION + + BLOCKING AS WITH 1/4" x 3 1/4" TAPCON (11/4" MIN B-B ROOF SHEATHING ATTACHED + REQUIRED b AO' /4" MAX EMBEDMENT INT;'�� PER NAILING SCHEDULE LL TO SUPPORT TRUSS + . . . I ... . I . . A - 7 F—CENTERED #5 BAR BLOCK HEADER SOLID BLKG. AT TOP BTWN. ARCH 21-0" 8" (5) -12d NAILS + SOFFIT + + W/ 1 X 4 FURRING BLKG. & BUCK 2X6 TO 2X4 USP RT3A 2X4 SYP 9 9 KNOCKOUT/ N EACH TRUSS P.. A CHAIR BLOCK 8d NAILS @ 8" O.C. AT BUCK PROVIDE 2 x 8 DIAG. BRACE B 2 x 8 VERT. W/ (2) 1 Od NAILS AT EA. END PROVIDE (2) MIN. PROVIDE 2x CONT. W/ CONNECTOR MONO FOOTING E % (3) SIZE AND REINF. PER PLAN VERT. BRACES WHEN HGT. 0 TAPCON AT EA. SIDE 12d NAILS BRACE EXCEEDS 24" BUCK - (1) WITHIN 4" JACK T RUSS PROVIDED BY SEE LINTEL SCHED. AND SECTION DETAILS v LEAVE A CUT OUT IN O.S.B. ON T MIN. OF START OF TRUSS COMPANY OR 2x4 CLEA N FILL 2 x 8 VERT. BRACE(S) INSIDE TO ALLOW FOR INSULATION ARCH #2 SYP @ 24" O.C. IT DIRT TO BE INSTALLED / BUILT UP PLWD. BUCK - /1 4'-0" MAX SEE PLAN PRECAST LINTEL A. SCRIBE (NOTCH) BACKSIDE 7/16" OSB ARCH PANEL 2X4 SYP #2 CONT. (MATCH TRUSS DEPTH SEE ELEVAT'ION 9SOTANDARD #5 BAR IN HOOK C14 TO FIT ARCH CONNECT W/ 8d NAILS "'-2 START OF ARC IF TRUSSES USED) W/ (2) #6 X 4%' WOOD FOR OVER HANG —(MAX. FILLEDCELL, L 1 x 4 SOLID BLKG. (FULL WIDTH OF WALLS) 4'MAX. RAD. SCREWS @ 16" O.C. MAX. OR IF MASONRY 4'-0") L V L. INSTALL WDW, SCREW BTWN. OSB ARCH FACES W/ (4) 1 Od NAILS EQUAL EQUAL WALL USE (2) 1/4" X 3 1/2" TAPCONS AT 16" ANCHOR INTO ARCH BLKG. THRU OSB INTO 2 x 8 O.C. PER INSTALLATION DETAILS -B B ARCH DETAIL rK SECTION @ ENTRY rL SECTION @ ROOF EXTENSION STEMWALL FOOTING SIZE AND REINF. PERLAN AND STEMWALL - SCALE: N.T.S. SS SCALE: 3/4" V-0" �s SCALE: 3/4" V-0" � �s MONO TO STEMWALL FOOTING SECTION DETAILS SCALE: 3/4" T-O" GLASS BLOCK INSTALLATION NOTES NOTE: IF RETROFIT FILLED CELL CONDITIONS A) COVER SILL AREA WITH A HEAVY COAT OF ASPHALT EMULSION. ALLOW EMULSION TO DRY EXCEED (3) PER PROJECT, CONTACT ENGINEER OF RECORD AT LEAST 2 HOURS BEFORE PLACING MORTAR. B) ADHERE EXPANSION STRIPS TO JAMBS AND HEAD. MAKE CERTAIN EXPANSION STRIP FOR ADDITIONAL INSTRUCTION. EXTENDS TO SILL. C) SET A FULL MORTAR BED JOINT, APPLIED TO SILL. MASONRY WALL. SEE PLAN FOR EXISTING BOND BEAM. D) SET LOWER COURSE OF BLOCK. MAINTAIN A UNIFORM JOINT WIDTH OF 3/8" PLUS OR MINUS REINFORCING. PROVIDE LOWER HOOKED DOWEL 1/8". ALL MORTAR JOINTS MUST BE FULL AND NOT FURROWED. ALL MORTAR SHALL BE "S" SEE SHEET D2 AND DRILL 3/4"X6" MIN. HOLE TYPE OR "N". STEEL TOOLS MUST NOT BE USED TO TAP BLOCKS INTO POSITION. (PLACE EXPANSION STRIP FLOOR PLAN FOR A RUBBER CRUTCH TIP ON END OF TROWEL TO TAP BLOCK INTO POSITION.) DO NOT 20 ga. PANEL MORE INFO SET BAR IN EPDXY REALIGN, TAP, OR OTHERWISE MOVE BLOCK AFTER INITIAL PLACEMENT. FOR SOLID GLASS ANCHOR HTT16W/(18)-16d NAILSTO CAP TO PREVENT LEAKAGE BLOCK IT MAY BE NECESSARY TO USE WEDGES IN THE MORTAR JOINTS OF THE LOWER W.W.M. AT PERIMETER COURSES TO PREVENT THE MORTAR FROM BEING "SQUEEZED" OUT. 1/4" EXPANSION BOLT (2 WHERE THIS CONDITION STUDS & (1) - 5/8" DIA. ALL #5X6'EMBEDDED INTO E) INSTALL PANEL REINFORCING IN EVERY OTHER MORTAR BED HORIZONTALLY AND IN JOINTS 9 ga. PANEL PER ANCHOR) (1) #5 BARS CONT. OCCURS THREAD ROD EPDXIED W/ "SET" EXISTING BOND BEAM IMMEDIATELY ABOVE AND BELOW ALL OPENINGS WITHIN PANELS. (THE SAME SPACING REINFORCING TOP WITH MIN. 3" SIMPSON EPDXY MIN. z 0 SHALL APPLY TO PANEL ANCHORS WHEN USED AT JAMBS AND HEADS IN LIEU OF CHANNEL (EVERY OTHER COVER 61-011 /--F.F. 5" EMBEDMENT & 3" MIN. FILL CELL FULL HEIGHT W1 OR CHASE SURROUNDS.) RUN REINFORCING CONTINUOUSLY FROM END TO END OF PANELS. COURSE) EXPANSION STRIP EDGE DISTANCE M U_ LU NON SHRINK GROUT. LAP REINFORCING NOT LESS THAN 6 INCHES WHENEVER IT IS NECESSARY TO USE MORE THANONELENGTH, DO NOT BRIDGE EXPANSION JOINTS WITH REINFORCING. INSTALL Uj CL A REINFORCING AS FOLLOWS: SEALANT U 0- PLACE LOWER HALF OF MORTAR IN BED JOINT. DO NOT FURROW. 55 • PRESS PANEL REINFORCING INTO PLACE. �&Ql 5X6'EMBEDDED INTO • COVER PANEL REINFORCING WITH UPPER HALF OF MORTAR BED AND TROWEL SMOOTH. DO NO FURROW. 6" MIN. LAP SPLICE W/ REINFORCING PANEL FF.LIEF LO C14 STING FOOTING 2-#5X6'IN CONIC. FILLED CELL DRILL 3/4"X6" MIN. HOLE F) PLACE FULL MORTAR BED FOR JOINTS NOT REQUIRING PANEL REINFORCING - DO NOT FURROW. MAINTAIN UNIFORM JOINT WIDTH. 'i 11"r I r GRADE -> *' , SET BAR IN EPDXY 6" MIN. LAP A' G) SET SUCCEEDING COURSE OF BLOCKS. SPACE AT HEAD OF PANEL AND JAMBS MUST SPLICE C14 REMAIN FREE OF MORTAR. NOTE: H) STRIKE JOINTS SMOOTH WHILE MORTAR IS STILL PLASTIC AND BEFORE FINAL SET. ATTHIS I" SEE GLASS BLOCK INSTALLATION NOTES. 04 — 0 1� TIME RAKE OUT ALL SPACES REQUIRING SEALANT TO A DEPTH EQUAL TO THE WIDTH OF THE SEALANT _'0 SAW CUT SPACES. REMOVE SURPLUS MORTAR FROM FACES OF GLASS BLOCKS AND WIPE DRY. GLASS BLOCK DETAIL (2) #5 REBAR. MIN. 3" TOOL JOINTS SMOOTH AND CONCAVE, BEFORE MORTAR TAKES FINAL SET. (REMOVE WEDGES FROM LOWER COURSES OF SOLID BLOCKS AND POINT THE VOIDS WITH MORTAR.) GLASS BLOCK SHALL BE INSTALLED PER THE FLORIDA BUILDING CODE RESIDENTIAL SECTION R160 16" MIN, COVER EA. WAY 7r �A SECTION 1) AFTER FINAL MORTAR SET (APPROX. 24 HOURS), INSTALL PACKING TIGHTLY BETWEEN EXISTING FOOTING GLASS BLOCK PANEL AND JAMB AND HEAD CONSTRUCTION. LEAVE SPACE FOR SEALING. �Jj SCALE: N.T.S. J) APPLY SEALANT EVENLY TO THE FULL DEPTH OF RECESSES IN ACCORDANCE WITH THE SECTION AT DEEP MONO FOUNDATION RETROFIT FOR MISSING MSTAM STRAP MANUFACTURER'S APPLICATION MANUAL AND INSTRUCTIONS. RETROFIT FILLED CELL DETAIL K) A MAXIMUM OF 60 SQUARE FEET OF GLASS BLOCK MAY BE INSTALLED IN ANY OPENING. SCALE: 3/4" = V-0" SCALE: 3/4"= V-0" FOR WIND SPEEDS UP TO 110 MPH*, PER PITTSBURG CORNING RECOMMENDATIONS FOR SCALE: N.T.S. INSTALLATION OF GLASS BLOCK. a (-D,o Z�; (0 0`1 4--J w U 0 -E 0 U1 00 170 Fn r- C-4 Cl) E 8 oil CUM E22 R 0.2,, M: aj 4) C) 00)) LL 00 -00 2 iz- (D _,4 < 0 (00 0.0 Lo 0 v Al 8 D. N C.- D-C T A �C,09 ZRI " 122 izz. I �.Q_ RUUI STE 1—=SAR v 255 Qj Lalj*'' w_ co E z LL LU < N. 0 7. at \Z C. IS To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code Sth Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. Z 0a) N 1-� :E� C) Q =3 kD > Ln ro C) p ro fo Ln z 00N U_ 0- �:_ fu cl� U S__L 00 z z § E z C:) Uj _j C:) W k.0 0 z Rn u, >_ 17 z (L < 0 LU z Uz< z U, Lzu 2z I 0 �n 0 R u_ U uj i.- N Z lun Z Z 8 L0 z z 0 -0 N Ln ru > z 0 U) _j < Lu Lu 6 (12 04 0, U-j >< 0 2 M- 2 C1 � - N, u�ya z F_ I Z Uj L0 i6u­be Lij L5j 6 z 0!� Iwo 5' z U_j P, U, z Z Z Ln Z �2 0 LU < V) z SCALE AS NOTED DATE 2/24/2014 TECH: MJAMES VERSION NO 10 SHEET NO. SS *DIAGONAL SPACED NOTE: PENDING BEAM AT 16-0" O.C. MAX BEARING LOCATION, THE 'E 'lu SEE ROOF PLAN SHEATHING AN SHI PROVIDE 2X4 MIN. BLOCKING AT Q OF HIP/RIDGE, TYP.BETWEEN TRUSSES W/ (2) 12D NAILS EACH 4 BEAM CAN SIT ON TOP OF COLUMN W/ (2) HTW20 STRAPS JACK TRUSS (AS SHOWN) OR GABLE END SEE TRUSS END TO TRUSS TOP CHORD LAYOUT 2X4 BLOCKING ,—CLIP EACH TRUSS BETWEEN TRUSSES TRUSS (2) 2x8 #2 SYP W/ USP JUS46 OR JUS461F (SEE ROOF PLAN BLOCKING A 7/16" O.S.B. FLITCAH BUCKET TO COLUMN FOR TYPE) SECT. A -A PLATE TOP @ TRUSS FRAME OUT TO BRG. SUPPORT COLUMN BUILT-UP BLOCK EDGE A (2)-2x4's OR 4x4 W/ (2)-10d G.T. NAILS @ 8" O.C. EACH PLY ----SEE DETAIL 4/131 (SHOWN AS 4 x 4) FOR BEAM SIZE ADD 2X4 ALONGSIDE EXTERIOR SHEATHING TOP CHORD WHEN REQ'D (2) USP HTA20's ATTACHED PER NAILING TO PREVENT PLYWOOD TYPICAL BLOCK w/(l 0)-1 Od x 1 1/2 EA. TO COL. SCHEDULE SPAN FROM EXCEEDING JACK WALL ALT: (2) USP MSTAM36 2x SPF #2 MAX 24" SPAN (EITHER �RUSSES HIP STRAPS CENTERED AT 16" O.C. SIDE OR BOTH IF REQ'D) G.T w/(l 3)-1 Od NAILS Ea TO COL. TIE BEAM --------BUILDER FRAME CONTINUOUS LATERAL BRACING- JN_ N RADIUS NAIL OVER X-BRACE AS SHOWN- AS REQUIRED INSTALL BLKG. AT TRUSS WEBS (2) 12D NA LS FOR NAILING AT 12" O.C. MAX X-BRACING - 2x4 SPF OR SYP BEAM @ RAISED ENTRY w/ 2-16d @ EACH TRUSS WEB CROSS BRACING DETAIL (TYP)r-j-'� HIP/RIDGE BLOCKING DETAIL MASONRY WALL KNEEWALL @ ENTRY FRONT WALL SCALE: 1/2" = 1'41 SCALE: 1/2"=V-0" SCALE: 1/2" = l'-O" SCALE: 1/2" l'-O" TRUSS NOTES: TYP. HAND FRAMING ABOVE TRUSS 1 . WOOD TRUSS ERECTOR SHALL PROVIDE BRACING ACCORDING TO ANSI/TP1-2002 CONV. FRAMED RIDGE 2X4 STUDS & PLATES AT Z-O" O.C. MAY BE NAILED EACH DIRECTION TYP. U.N.O. USP LSTA18 PLAN (TRUSS PLATE INSTITUTE) NOTE THAT THE COMBINED WIND AREA IS GREATER VERTICAL SCAB w/ MIN. (4) 12d WHEN CENTERED @ USP HD4101F BUCKET L.SEE 1, BEFORE THE ROOF SHEATHING IS APPLIED, AND BRACING SHALL THEREFORE BE 2 x 6 #2 SPF 48" O.C. IT LANDS NEXT TO SPLIT TO TIE SEE ROOF PLAN FOR 1 FOR CANTI INSTALLED AS THE TRUSSES ARE ERECTED. INADEQUATE BRACING IS THE MOST W/ (4) 10d TOP & PRE-ENG. TRUSS BEAMS TOGETHER MORE INFO ------,.— COMMON CAUSE OF ACCIDENT IN WOOD TRUSS CONSTRUCTION. FULL BUNDLES 2x8 BLKING. NAILED @ EACH BOTTOM OR USP RT7 OF PLYWOOD SHALL NOT BE PLACED ON TRUSSES. THIS CONSTRUCTION LOAD SIDE w/ (3) 12d NAILS WHEN OR HCLR/LL W1 8 - 8d SHOULD BE LIMITED TO 8 SHEETS OF PLYWOOD ON ANY PAIR OF TRUSSES & REQUIRED wl (2) USP HTW20 IN PLACE OF (4) 10d 71/_ SHALL BE LOCATED ADJACENT TO THE SUPPORTS. NO EXCESS CONCENTRATION W/ (14) - 1 Od X 1 1/2" EACH —SEE FLOOR PLAN FOR OF ANY CONSTRUCTION MATERIAL (SUCH AS GRAVEL OR SHINGLES) SHALL BE PLACED COLUMN SIZE& BASE OSB FLITCH PLATE ON THE TRUSSES IN ANY ONE AREA THEY SHALL BE SPREAD OUT EVENLY OVER SEE FLOOR PLAN CONNECTION INFO LL REQ'D ONLY WHEN A LARGE AREA SO AS TO AVOID OVERLOADING ANY ONE TRUSS. /--COLLAR TIE �Z EVERY 3rd FOR COLUMN SIZE &ADDITIONAL INFO. ___--7116" INDICATED ON BM. SCHEDULE/PLAN 2x4 #2 SYP NAILER. NAIL 2. ALL BRACING (DB,CB,BB) SHOWN ABOVE SHALL BE IN ADDITION TO CONTINUOUS OSB FLITCH PLATE — SEE FLOOR PLAN FOR TO STUDS w/3-16d @ LATERAL BRACING SPECIFIED BY THE TRUSS MANUFACTER ALL LATERAL BRACING RAFTER REQ'D ONLY WHEN COLUMN SIZE& BASE O�T EA. STUD. TOENAIL EA. ROOF AND EXTERIOR SPECIFIED BY TRUSS MANUF. SHALL HAVE ADDITIONAL DIAGONAL BRACES AT 20-4- OPTION INDICATED ON BM. A CONNECTION INFO OPTION B OPTION C. TRUSS TO NAILER w/3-1 Od SHEATHING ATTACHED O.C. MAXIMUM. SPF 2 SCHEDULE/PLAN PER NAILING SCHEDULE ----2x4 3. ALL BRACES SHALL BE 2X4 NOMINAL DIMENSION LUMBER & SHALL BE ATTACHED W1 2-16D (2) #7X 3-1/2" WOOD NAILS AT EACH TRUSS INTERSECTION. CB—_ SCREW EACH TRUSS COMMON BM. TO POST ATTACHMENT SEE 2ND FLOOR WALL SECTION 4. ADDITIONAL BOTTOM CHORD BRACING SHALL BE INSTALLED AS REQUIRED BY TRUSS OR USP RT7 @ 48" O.C. FOR ADDITIONAL INFORMATION DESIGN WHEREVER ADEQUATE STRUCTURAL CEILING ARE NOT s'j B SEE ROOF PLAN ATTACHED DIRECTLY TO THE BOTTOM CHORD OF THE TRUSS. DB--<; B FOR BEAM SIZE & SCALE: 3/4"=V-0" 5. PROVIDE TRUSS BLOCKING AT ALL TRUSS BEARING SUPPORTS WHERE TRUSS BEVEL CUTS CONNECTION INFO. BM, SPLICE OVER CENTER OF POST DEPTH EXCEEDS STANDARD HEEL HEIGHT. SEE TYP. TRUSS BLOCKING DETAILS (OPTIONAL) F PRE-ENG. TRUSS A A — 2X4 DIAGONAL AT 8'-0" O.C. 2X4 BLOCKING BETWEEN EA. TRUSS CONT. ROOF SHEATHING AT TRUSS TOP SEE PLAN FOR TOPOFBEA­M MAX & EACH END ALTERNATE CHORD AT ALL HAND FRAMED AREAS TYP. /7 DIRECTION TYP. A=CZ: DIAGONAL---- 2x8 #2 SPF RIDGE BEAM AT 81-0-1 x __�—WOOD MAX TRUSS 2x6 #2 SYP RAFTERS FOR SPANS 4FT USP ST USP ST1 8 TO 8FT 2X4 RAFTERS FOR SPANS LESS TYP. U.N.O. SEE PLAN FOR TYP. U.N.O. x THAN 4FT @ Z-O"O. C. MAX. w/ (3) 1 Od SEE FLOOR PLAN FOR CANT. IF INDICATED USP JU26 OR IF 2 PLY COMMON TOENAILS TO RIDE BEAM COLUMN SIZE & TRUSS USP JUS26-2 SEE FLOOR FRAMING 2X4 CONT. AT CONC.MASONRY ADDITIONAL INFO. (WOOD COLUMN SHOWN) TRUSS TO LEDGER PLAN AND J/S6 FOR MORE 2X8 #2 SYP CONT. LEDGER w/ T & B CHORD STEEL OR WOOD MIDDLE (4) 16d NAILS ATTACH NAILS INFO. VERIFY WITH PLAN FOR LOCATION BEARING SUPPORT INTO END OF EACH FLOOR AND .0 TRUSS, 24" O.C. MAX. (AT DIRECTION (IF PARALLE EACH SIDE OF G.T. INSTALL SEE 2/D2 FOR BLOCKING A -A ALTERNATE BLOCKING CORNER (4) NAILS EACH SIDE). INFO) SEE FOUNDATION DETAIL @ INTERIOR BEARING PLAN FOR MORE INFO 511 MASONRY WALL (TYPICAL) ----------ZWOOD J SCALE: 1/2" V-0" COMMON BM. ATTACHMENT r18 TRUSS PROVIDE BLOCKING AT ALL TRUSS BEARING SCALE: 3/4"=V-0" SECTION AT LOW ROOF SUPPORT WHERE TRUSS DEPTH EXCEEDS SCALE: 1/2" V-0" TYP. WOOD TRUSS BLOCKING DETAIL STANDARD HEEL HEIGHT 7_7 SCALE: 1/2"=V-0" VARIES 2x STUDS @ 16" O.C. ROOF SHEATHING SEE 1/S5 FOR SEE PLAN FOR W/ USP SPT22 @ ATTACHED PER ADDITIONAL 8d NAILS AT VALLEY TRUSS BASE & SPT24 @ TOP 2x4 #2 SPF BRACING @ NAILING SCHEDULE EXTERIOR SHEATHING OUTLOOKER 4" INFO. O.C. INFO. 2x BLOCKING BETWEEN 16" O.C. W/ (4) 12d COMMON TRUSSES. ATTACHED PER ----- ---- STUDS TO TRUSS W/ (2) TOENAILS TO TOP SEE TRUSS PLAN 2x4 STUDS W/ USP NAILING SCHEDULE 12d TOENAILS EACH END —STRUCTURAL SHEATHING PLATE & (2) 12d END MIN. (2) 2x4 FOR CONNECTION NAILS TO TRUSS SPFTOP INFORMATION. SPT22 @ BASE SEE J/S6 FOR MORE (BETWEEN TRUSSES (2) 12d NAILS TO EACH ATTACHED PER NAILING BOTTOM CHORD PLATE INFO. GABLIi TRUSS LOW ROOFIWALL VERTIVAL STUD) SCHEDULE SHEATHING ATTACHE X Z PER NAILING SCHEDULE 2x BASE PLATE W/ (2) 12d VARIES W/ OILVARIES SEE PLAN FOR WALL LOCATION 2x4 BASE PLATE W/ /—USP 1/2" PLYWOOD NAILS @ 16" O.C. ALONG W/ USP MTW12 TO BLOCKING ROOF SLOPE LSTA30 OR MTW1 2 TO FLOOR (2) 16d NAILS TO BELOW @ 16" O.C. WOOD WALL—\ GIRDER BELOW @ 16- x EACH COMMON TRUSS/ FRAMING OR TRUSS. '--2X4 CONT. W/ (2) MIN. 2x4 #2 SPF STUDS @ O.C. TYP TOP & BOTTOM SEE PLAN 16d COMMONS 16" O.C. W/ EXTERIOR ------­- — ­­ --- NAILS EACH SHEATHING ATTACHED x STUD TYP. T&B PER NAILING SCHEDULE & MASONRY WALL BELOW: USP PLYWOOD (3) 12d TOENAILS TO >< HTA16 @ 4'-0" O.C. TO GABLE FLOORING TRUSS OR SEE PLAN FOR PLATE BELOW MASONRY WALL _. 4 TRUSS BEAM BELOW: USP ROOF SYSTEM TOP OF WALL OR BEAM HTW20 @ 4'-0" O.C. TO GABLE MIN. 2x4 #2 SYP P.T. PLATE 16" FLOOR SYSTEM FLOOR GIRDER SEE TRUSS PLAN TRUSS 1(9) W/ 1/2"X8" EPDXY ANCHOR SEE PLAN FOR SEE PLAN FOR COMMON TRUSS LOW ROOF TRUSS W/---/ 2x6 BLOCKING U FLOOR G.T. NDER MASONRY WALL SEE @ 3" FROM EACH END & DIRECTION CONNECTION SEE ROOF PLAN RAISED BOTTOM CHORD 2nd FLOOR WALL W/ USP SEE PLAN PLAN FOR MORE 16" O.C. MAX. FOR CONNECTION EXTENSION SEE TRUSS JUS24-2 EACH END SHEAR TRANSFER INFO. SECTION @ FLOOR MANUF. SPEC'S FOR CONNECTIONS TO G.T. EXTERIOR. WALL SECTION @ ENTRY KTN� CONNECTION r2 2 SECTION AT HIP GABLE SECTION @ BUMP OUTr3q SCALE: 3/4" = V-0" SCALE: 3/4" = l'-O" SCALE: 3/4" = V-0" SCALE: 3/4" = V-0" SCALE: 3/4"=V-10" DETAILS & SECTION (D !;2 z (0 Lu z U) z La V) (D (1) C-0 4--d u-i 0 W L/) 0-1 E 0 :D ch co U0 00 ULj C ca n E 0 T 72 M 0 8 C', 0 C) Cn co 0 -id W 0.0 Lo 0 'T < 0 0. < C; ARA I N.C.B.D C 'j v LO P40� S E LUT' PH' IP -P r q it LU aj < 9 04 to 0 LLCj S� C E S q I - To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building code Sth Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. Z 0 4_j C:) *5 > M Ln :2 w Ln LZ LL re) alg U co z < E z z C:) WUj _j C:) 0z OR tj z< g8o, Lu I<X 0, zz Uj Z R�uu 8 Lu 8 tunl Z Z Ln 0 P= z 0 -0 b -4 (D Lr) L_Lj W 0 > z _< Lu U C/) _j > 0 R OZ t5xU06 LU Mz uj < 0:, Z z LU r%j Ln 0.2i _j 6i 6i 91-8 0 z U 2 uj TV Z CY < v) (n z M 0 z W Ln z LU rn V) SCALE AS NOTED DATE 2/24/2014 TECH: MIAMES VERSION NO 10 SHEET NO. D1 EXT. SHEATHING FLUSH W/ TOP -SEE FOR 2 OF MASNORY & 8d rSEEFOR BLOCKING NAILS T/B FLANGE BLOCKING DETAILS DETAILS 2xSTUDS ....... —FLOOR SYSTEM M SEE PLAN 7E G.C. VERIFY INTERIOR 1/2" GYP. BOARD OR (2) USP MSTAM36 STRAPS w/ (8) 1 Od EXTERIOR STRUCTURAL NAILS & (5) Y4" x 2 Y4" TAPCONS SHEATHING (MIN. 7/16") CENTERED ON FLOOR SYSTEM TO VERIFY W/ PLAN MASONRY WALL BELOW. CONTRACTOR MAY USE (2) SIMPSON MSTAM36 STRAPS W/ (7) 1 Od NAILS & (4) )/4" x 2 Y4" TITENS INSTEAD OF USP MSTAM36 STRAPS. IF SCALE: 1 1/2" V-0- WOOD WALL IS BELOW USE (2) MSTA36 SCALE:3/4" 1'- 0" STRAPS w/ (22) 1 Od NAILS OR (2) SEE SS FOR RETROFIT SIMPSON MSTA36 STRAPS W/ (26) 1 Od CONNECTION IF MSTAM36 NAILS (G.C. TO INSURE SOLID BLOCKING CAN NOT BE INSTALLED IS INSTALLED). EITHER USP OR SIMPSON SECTION CORNER STRAPS ARE ADEQUATE FRAMING ATTACHMENT AS NOTED (2)- 12d GABLE END FLOOR TOENAILS 2x4 TRUSS SEE R/S6 FOR TO TRUSS TOP CONNECTION INFO TO MASONRY WALL BELOW AND ALT. BLOCKING INFO G) 0 1. APPLY SUB LO FLOOR + ADHESIVE TO 2x4 CONTACT SURFACE A 2x4 #2 BLOCKING 2 NOTE: VERIFY WITH FLOOR B 2x4 SIDE BRACE FRAMING PLAN FOR I -JOIST AT 48" O.C. OR FLOOR TRUSS FOR BETWEEN JOISTS CORRECT BLOCKING w/ (3) 12d EA. END REQUIREMENTS TO HORIZ. BLOCKING 1-1/8" RIM BOARD 8d NAILS @ 3" O.C. JOIST SEE PLAN WALL SHEATHING (2) - 12d TOE NAILS TOP TO RIM BOARD & BOTT. CHORD AJS BLOCKING PANEL @ 24" O.C. (MAX) AND @ EACH GABLE END RIM JOIST— END OF WALL UNDER SEE R/S6 FOR CORNERS CONNECTION INFO TO (2) - 10d TOE NAILS MASONRYWALL EACH SIDE BLOCKING DETAIL r2 SCALE: 3/4" V-101" 11�1"j SEE SS FOR RETROFIT CONNECTION IF MSTAM36 CAN NOT BE INSTALLED (3) 2x # SPF X STUDS w/ 10d @ 8" O.C. EACH SIDE U.N.O. ON PLAN 2X CONT. RIBBON TYPICAL BLOCK WALL (2) USP MSTAM36 STRAP(S) CENTERED W/ (8) 10d NAILS & (5) 1/4 TAPCONS. CONTRACTOR MAY USE SIMPSON (2) MSTAM36 W/ (7) 10d NAILS & (4) Y4"xV4" TAPCONS INSTEAD OF USP STRAP. EITHER STRAP IS ADEQUATE GIRDER/COL. CONN. 1 OR 2 PLY GIRDER TRUSS. SEE PLAN FOR CONNECTION. SEE PLAN FOR CONN. (2) - 2x SPF TOP PLATE FLOOR DECK FLOOR TRUSS/ I -JOIST SEE PLAN TIE BEAM PROVIDE BLOCKING BELOW JAMBS 2nd FLOOR SCALE: 1/2" V-0" (1) USP LSTA30 STRAPS BENT OVER TOP PLATE THEN DOWN THE FACE USP SPT4 W/ (6)-1 Od X 1 1/2" OF HEADER/STUDS W/ @ 24" O.C. (22) 1 Od NAILS (2) - 2x SPF TOP PLATE 2x CRIPPLES @ 16" 0 C (2) 2x HEADER SEE PLAN Wit (2) 12d TOENAILS T/B INTERIOR HEADER (2) 1 Od TOE NAILS AT EA. (1) 2x SILL PLATE W/ (2) 12dTOENAILS. I EXTERIOR HEADERS END OF SILL. MAX, OPENING WIDTH 4 FEET. (1) 2x SILL PLATE Wit (2) 12d TOENAILS. OPENING LARGER THAN 4 ft (2) 2x IF OPENING IS GREATER THAN 4 FEET BUT NOT SILL PLATE W/ MP3 CLIPS EACH SIDE EXCEEDING 6 FEET. A MP3 CLIP IS TO BE MIN (3) 2x #2 SPF STUDS @ END INSTALLED AT EA. END OF HEADER SEE Q/S4 FOR REQ'D - J JAMB INFO 2x CRIPPLE AT EA. USP LSTA 30 w/ (11) - 1 Od END OF OPENING TO STUDS ABOVE PLATE NAILED TO STUD PACK w/1 Od NAIL FLOOR DECK @ 8"O.C. "nz FLOOR TRUSS/ I -JOIST SEE PLAN USP LSTA30 FROM WINDOW JAMB TO FLOOR TRUSS/ SOLID BLOCKING BELOW. SEE 8/D-2 FOR ALT. CONDITION. DETAIL TO BE FOLLOWED IF DOWN SET OR BOX HEADER IS USED OTHERWISE DETAIL CAN BE IGNORED HEADER CONN. @ 2nd FLOORr4N� SCALE: 1/2" V-0" SEE Q/S4 FOR JAMB STUD USP SPT24 @ EA. STUD W/6-10d SEE SS FOR RETROFIT SEE 8/D-2 FOR ALT. CONDITION. DETAIL TO BE CONNECTION IF MSTAM36 FOLLOWED IF DOWN SET OR BOX HEADER IS USED 2x6 / 2x8 CRIPPLES @ 16" O.C. USP SPT4 W/ (6)-1 Od X 1 1/2" TO STUD & TO TOP PLATE NOTCHED @ HEADER LOCATION SEE (2) 2x8 OR (2) 2x6 TOP REQ'D TY @ 24" O.C. USP LSTA24 W/(18)-10d NAILS CAN NOT BE INSTALLED OTHERWISE DETAIL CAN BE IGNORED INFO BELOW ON CONNECTION OF PLATE SEE PLAN TYP A 2-2x4SPF (K) USP RS1 50 W1 MIN. 12" END USP SPT4 W/ (6)-1 Od X 1 1/2" 2x HEADER TO SIT A TOP PLATES LENGTH ON STUDS W/ (11) 1 Od (1) USP LSTA30 STRAPS BENT @ 24" O.C. NAIL BACK LEG OF CIPPLE TO (2) NAILS TO STUDS ABOVE & (11) 1 Od OVER TOP PLATE THEN DOWN (2) - 2X SPF TOP PLATE HEADER w/ (2) 12 TONEAILS FLUSH w/ THE OUTSIDE NAILS TO STUDS BELOW. THE FACE OF HEADER/ STUDS 2 x 4 #2 SPF STUDS W/ (22) 1 Od NAILS (2) 2x HEADER SEE PLAN 2x6 / 2x8 WALL BEYOND SEE C AT 16" O.C. U.N.O. D USP SPT22 W/ (6)-10d TO STUD & NAILING AREA (TYP.) HEADER FLUSH TO OUTSIDE FLOOR PLAN FOR HEADER (2) 2x HEADER (4) - 1 Od TO PLATE 5/8" A.B. @ 24" O.C. AND 6" FROM MIN (3) 2x #2 SPF STUDS @ INTERIOR HEADER SEE PLAN FOR COL. SIZE CONNECTION SEE PLAN (2) USP MSTA36 STRAPS CENTERED SEE STANDARD HEADER EACH END W/ 7" EMBEDMENT. IF END OF HEADER SEE Q/S4 FOR (1) 2x SILL PLATE W/ (2) 12dTOENAILS. W/ (22) ld NAILS OR (2) SIMPSON DOUBLE 2x6 OR 2x8 TOP CONNECTION DETAILS FOR AT STEP DOWN LOCATION, MIN 7" REQ'D JAMB INFO EXTERIOR HEADERS MSTA36 STRAPS W/ (26) 10d NAILS PLATE SEE PLAN 2 SPF EMBEDMENT PAST STEP. x (1) 2x SILL PLATE W/ (2) 12d TOENAILS. FLOOR SYSTEM OR (EITHER USP OR SIMPSON STRAPS 12d NAILS AT 6" K-f [B�AjE PLATE USP SPT4 EACH STUD 2x CRIPPLES @ 16" O.C. OPENING LARGER THAN 4 ft (2) 2x SILL PLATE W/ MP3 CLIPS EACH SIDE 2-STY. RAMING 1� ARE ADEQUATE) O.C. TYP T & B USP SPT6 OR C B B D W/ (2) 12d TOENAILS T/B BAND JOIST & BLKG. (2) 2 x #2 FLOOR SYSTEM OR IF BUILT-UP STUDS ARE (2) - 10d TOENAILS AT EACH END OF KNE L R BEAM W/IN WALL SYSTEM A.B. TO BE SILL (MAX. OPENING WIDTH 4 OR LVL GIRDER SYP U.N.O. SPACED W/IN 6" FROM OPENINGS (2) - 2 x 4 SPF 2X CRIPPLE AT EACH END OF FEET). IF OPENING IS GREATER (BLOCK SOLID) AND MULTIPLE STUD PACKS TOP PLATES OPENING NAILED TO STUD THAN 4 FEET, BUT NOT EXCEEDING SEE PLAN FOR 2 x CONT. T & B INTERIOR HEADER PACKW/ 10d NAILS@ 8"O.C.— 6 FEET, A MP3 CLIP IS TO BE INSTALLED TO EACH END COL. SIZE (1) 2x SILL PLATE W/ (2) 12dTOENAILS. 2 x 4 #2 SPF STUDS EXTERIOR HEADERS (1) 2x SILL PLATE W/ (2) 12d TOENAILS. TYPICAL BLOCK WALL--------, PLYWOOD ATTACHED PER NAILING SCHEDULE T4 USP HT 5 BASE W/ (2) 2x HEADER AT 16" O.C. U.N.O. \--�JG OPENING LARGER THAN 4 ft (2) 2x SILL FLOOR TRUSS/ I -JOIST SEE PLAN V. (18) 16d NAILS & %" ANCHOR BOLT W/ BOX HEADER SEE PLAN F PLATE W/ MP3 CLIPS EACH SIDE 2 x 4 P.T. STUDS UNDER 2nd FLOOR HEADER USP MSTAM36 STRAP(S) CENTERED W/ (8) 10d NAILS L TIE BEAM MIN. 6" EMBEDMENT (2) LSTA12 WRAPPED UP (2) 2x TOP PLATE BASE PLATE ARE NOT REQ'D TO HAVE & (5) 1/4 TAPCONS. AND OVER TOP PLATE CONTRACTOR MAY USE PROVIDE BLOCKING 2x CRIPPLES @ 16" O.C. W/ USP SEE FOUND. PLAN FOR FTG. REQ. CONNECTIONS. ATTACH STUDS W/ (3) 12d TOENAILS T&B SIMPSON MSTAM36 W/ (7) BELOW JAMBS SPT22 & SPT24 (OR SPT4) 10d NAILS & (4) 4"X24" CONNECTORS @TOP' PROVIDE EXTERIOR SHEATHING TAPCONS INSTEAD OF USP -SEE FOUNDATION PLAN PROVIDE (2) CRIPPLES BELOW TO ANY GIRDER TRUSS IN THIS 2 ST. INT. BEARING WALL ATTACHED PER NAILING SCHEDULE STRAP. EITHER STRAP IS ADEQUATE FOR FTG. REQ. 2x CRIPPLES TO SITUATION. CONNECT G.T. TO FOR EXTERIOR 2 STORY WALLS ONLY. MATCHJACK STUDS W/ (2) - HTW20 TOP & (2) AND EXTERIOR SHEATHING CAN STOP ONCE UNDER r5 HEADER CONN. 2nd FLOOR (6 STUDS BELOW HTW20 @ BASE TO HEADER LOWER ROOF. 2 STORY COL. GIRDER (IF CRIPLLES ARE LESS THAN 8" LONG NO STRAPS ARE SCALE: 1/2" V-101" SYSTEM 42 SCALE: 1/2" = V-10" REQ'D) SCALE: 1/2" V-10" L �_ADDITIONAL STRAPS ,�SEE STANDARD HEADER REQUIRED AT TOP PLATE CONNECTION DETAILS FOR TO STUDS TO MATCH MORE INFORMATION HEADER STRAPS SEE SS FOR RETROFIT SEE 8/D 2 FOR ALT. CONDITION. DETAIL TO BE CONNECTION IF MSTAM36 FOLLOWED IF DOWN SET OR BOX HEADER IS USED CAN NOT BE INSTALLED OTHERWISE DETAIL CAN BE IGNORED (2) LSTA24 (2) 2x HEADER SEE PLAN SEE 8/D-2 FOR ALT. CONDITION. DETAIL TO BE FOLLOWED IF DOWN SET OR BOX HEADER IS USED (2) USP LSTA30 STRAPS US P S PT4 W/ (6)-1 Od X 1 1/2" 2X4 STUDS MIN (3) 2x #2 SPF STUDS @ END OF HEADER OTHERWISE DETAIL CAN BE IGNORED BENT OVER TOP PLATE @ 24" O.C. PER PLAN SEE Q/S4 FOR REQ'D JAMB INFO THEN DOWN THE FACE OF (2) 2x HEADER SEE PLAN USP MP3 EACH END TYP. FOR OPENINGS LESS THAN 4'-0" WIDE, (1) USP LSTA30 STRAPS BENT HEADER/STUDS W/ (22) 10d NAILS 2x CRIPPLES @ 16" O.C. DOUBLE 2X4 TOP PLATE SILL MAY BE ATTACHED W/ (2) - 16d OVER TOP PLATE THEN DOWN USP SPT4 W/ (6)-10d X 1 1/2" W/ (2) 12d TOENAILS T/B TOENAILS @ EACH END THE FACE OF HEADER/ STUDS @ 24" O.C. INTERIOR HEADER 2 WS 10d @ (2) 2x SILL PLATE W/ (22) 1 Od NAILS (2) - 2X SPF TOP PLATE M IN (3) 2x #2 SPF STUDS (1) 2x SILL PLATE W/ (2) 12dTOENAILS. It 3' 0/ _�����2x 2x CRIPPLES @ 16" 0 C (2) 2x HEADER SEE PLAN @END OF HEADER. SEE EXTERIOR HEADERS (1) 2x SILL PLATE W/ (2) 12d TOENAILS. �STUDS @ 16" O.C. W/ (2) 12d TOENAILS T/B INTERIOR HEADER Q/S4 FOR REQ'D JAMB OPENING LARGER THAN 4 ft (2) 2x TOP SPLICE (1) 2x SILL PLATE W/ (2) 12dTOENAILS. INFO. EXTERIOR HEADERS SILL PLATE W/ MP3 CLIPS EACH SIDE (2) - 1 Od TOENAILS AT EACH END OF SILL (MAX. OPENING (1) 2x SILL PLATE W/ (2) 12d TOENAILS. THAN 4 2x CRIPPLE AT EACH END OF OPENING NAILED TO STUD (2) - 1 Od TOENAILS AT EACH END OF SILL (MAX. OPENING WIDTH 4 FEET). ALT. HEADER ANCHOR WIDTH 4 FEET). IF OPENING OPENING LARGER ft (2) 2x SILL PLATE W/ MP3 CLIPS EACH SIDE PACK W/ 1 Od NAILS IF OPENING IS GREATER THAN 4, r8 IS GREATER THAN 4 FEET FEET BUT NOT EXCEEDING 6 FEET, BUT NOT EXCEEDING 6 FEET, MIN (3) 2x #2 SPF STUDS @ END TYPICAL BLOCKWALL A MP3 CLIP IS TO BE INSTALLED AT PROVIDE 2X4 ON SCALE: N.T.S. A MP3 CLIP IS TO BE INSTALLED AT EACH END OF HEADER SEE Q/S4 FOR EACH END. TOP OF 2x8 TO REQ'D JAMB INFO FLOOR DECK BLOCK OUT TOP 2x CRIPPLE AT EACH USP LSTA30 CENTERED FLOOR TRUSS/ I -JOIST SEE PLAN PLATE ATTACH END OF OPENING W1(22) 1 Od NAILS (2) USP MSTAM36 STRAP(S) 2X CONT. RIBBON W/ (2) 1 Od NAILS - NAILED TO STUD PACK W/ 1 Od NAILS @ 8"o.c. FLOOR DECK CENTERED W/ (8) 10d NAILS & (5) 1/4 TAPCONS. TIE BEAM @ 3" O.C. 2x4 BEYOND AGAINST 2x8 DOUBLE ol 6 5, CONTRACTOR MAY USE 2x8 TOP - FLOOR TRUSS/ I -JOIST SEE PLAN S I M PSO N (2) M STAM 36 Wit (7) PROVIDE BLOCKING STUDS PLATE SEE PLAN FOR BEAM 1 Od NAILS & (4) Y4"x2Y4" BELOW JAM BS 2x8 STUDS 2x4 Wit 2 ROWS SIZE & CONNECTIONS TAPCONS INSTEAD OF USP NOTE: PER PLAN OF 10d NAILS STRAP. EITHER STRAP IS PLATE LENGTHS MUST BE @ 3" O.C. HEADER CONN. 2nd FLOOR ADEQUATE HEADER CONN. @ 2nd AT LEAST 4'-0" LONG. TYPICAL W/ HIGH BM FLOOR [DOUBLE STRAP] TOP PLATE SPLICE DETAIL SCALE: 1/2" = V-0" SYSTEM 42 SCALE: 1/2" = V-0" SCALE: 3/4" = V-0" 0"'a Z�; U z V) 0 Q) — 4--J (10 n U 0 LU V) ix ::D 1, 0 0) 0 C') V) .20 M rn r- W Cf) LU E 0 0) M a cc cy) 00 C14 q (OD w -C FL 0 1:5 _800 0 cu_ 42) le < 0 0 C:) CL 0)< 6 A a Do I I D-c co 0 Z M N r.. -NM _g * lib �T. �t 4� .2 .- Ix 5 [z — (I 4Q -04- Ul W—jo _j Qj 3t z .0 v z i4 -'Z- Fl- LL JU , C, 0 F E S Sur To the best of the Engineer's knowledge, information, and and seal is only for the structural en gineering portions of the drawing pages bearing Engineer's signature and seal. C) C) Z r4 0 (1) r-, =3 t.0 C) > M r') p M Ln z < LL Lr, CL U CL 00 z z 3i E z LLJ _j C) W 0, z< z z E 8,0 0 0 0� La a, Z z z ui Z 2 g�.2 � 0 LL, i- N Cl) M z @ 8 ULL I) Z z 0 L0 0 U 2: z z 0 -0 D M M Cl) 0 06 U C/) < I _P0 50 Lu LL, 8 U.� 0. r_4 LU.2 Z z LLj r-4 L0 a- 2 <, 8 Uj < 0, 2 �ze Lu i5 ro Z z tu- 0� < (DIV) U) M 0 TV z LU Z 0 < V) V) SCALE AS NOTED DATE 2/24/2014 TECH: MJAMES VERSION NO 2mO SHEET NO. D2 S. z THESE DETAILS ARE GENERIC AND MEANT TO SHOW GENERAL FLASHING AND WATERPROOFING METHODS TO BE USED. af%l r% I in WE ER �/E BARRIER & tARILY SECURE HEAD FLASHING TIE-IN INSTRUXTIONS: I . Cut, fold up & temporarily secure weat barrier above header to allow for flashing installation 2. Self -adhered flashing plus head flashing under weather resistive barrier 3. Fold weather resistive barrier back over head flashing and seal with tape Scale: NTS SELF -ADHERED FLASHING FLANGED WINDOW FLASHING INSTALLATION AFTER WEATHER RESISTIVE BARRIER EXTERIOR SHEATHING REFER TO TECHNICAL LETTER ON C EM H ICAL COMPATIBILITY SELF -ADHERED FLASHING EXTERIOR SHEATHING WOOD FRAME CONSTR. SELF -ADHERED FLASHIN BY LAPPING DOWN --�, OVER RIM JOIST AND UP WALL BY 6 IN. WEATHER RESISITIVE BARRIER SEAL TOPS OF JOIc UNDER DECKING (SEE DETAIL WP07) ED FLASHING SELF -ADHERED FLASHING NAILING FLANGE 1 DO NOT FLASH OVER 2 BOTTOM NAILING 8 FLANGE § SELF -ADHERED FLASHING HALF ROUND WINDOW WEATHER RESISTIVE BARRIER DOOR ROUGH OPENING 3/4"-l" BEAD OF CONSTR. ADHESIVE TO BE APPLIED UNDER THRESHOLD OF DOOR AND RETURN UP JAMB 6". USE LIQUID NAIL BRAND OR EQUAL WEATHER PROOF CAULKING SELF -ADHERED FLASHING SUBFLOOR SELF -ADHERED FLASHING EXTERIOR DOOR WITH DECK - SECTION A EXTERIOR SHEATHING 3/4"-l" BEAD OF CONSTR. ADHESIVE TO BE APPLIED UNDER THRESHOLD OF DOOR AND RETURN UP JAMB 6". USE LIQUID NAIL BRAND OR EQUAL WEATHER PROOF CAULKING SECTION -A (SEE DETAIL WP02) SELF -ADHERED FLASHING SEAL TOPS OF JOISTS UNDER DECKING (SEE DETAIL WP07) SELF -ADHERED FLASHING EXTERIOR DOOR WITH DECK 2 WP07 WP08 WP09 RIM JOIST INSTALL SELF -ADHERED FLASHING JAMB & HEAD FLASHING, SEE FLANGED WINDOW (SEE DETAIL WP01) SELF -ADHERED FLASHING, EXTEND A MINIMUM 6" VERTICALLY FROM BOTTOM OF THRESHOLD SELF -ADHERED FLASHING PATCH WINDOW UNIT SLOPE 0.3 in: 12.0 in (0.6 cm : 30.5 cm) SELF -ADHERED FLASHING EXTERIOR CEMT, FIN. BUILDING PAPER WIRE LATH Q SELF -ADHERED FLASHING CEMT. FINISH SILL/ POTSHELF/ CHIMNEY SHOULDER MECHANICALLY FASTEN IF NEEDED IN CORNERS THROUGH SELF -ADHERED FLASHING RUBBERIZED ASPHALT RUBBERIZED ADHESIVE ASPHALT ADHESIVE SELF -ADHERED FLASHING F SELF -ADHERED FLASHING INSIDE CORNER Ground SCORED RELEASE P� PER (BEFORE FOLDING, SCORE RELEASE PAPER TO EXPOSE ADHESIVE AS SHOWN) Water Resistant Barrier Lath Sheathing Stucco FLASHING REQUIREMENTS R612.10 Flashing, Sealants and Weatherstripping. Flashing and sealants for exterior windows shall comply with Section R703.8. R703.2 Weather -resistant sheathing paper. One layer of No. 15 asphalt felt, free from holes and breaks, complying with ASTM D 226 for Type 1 feIt or other approved water -resistive barrier shall be applied over studs or sheathing of all exterior walls. Such felt or material shall be applied horizontally, with the upper layer lapped over the lower layer not less than 2 inches (51 mm). Where joints occur, felt shall be lapped not less than 6 inches (152 mm). The felt or other approved material shall be continuous to the top of walls and terminated at penetrations and building appendages in a manner to meet the requirements of the ext erior wall envelope as described in Section R703.1 Exception: Omission of the water -resistive barrier is permitted in the following situations: 1. In detached accessory buildings. 2. Under exterior wall finish materials as permitted in Table R703.4 3. Under Paperbacked stucco lath when the paper backing is an approved water -resistive barrier. R703.8 Flashing. Approved corrosion -resistant flashing shall be applied shingle -fashion in a manner to prevent entry of water into thewall cavity or penetration ofwater to the building structural framing components. Self -adhered membranes used as flashing shall comply with AAMA 711. The flashing shall extend to the surface of the exterior wall finish. Approved corrosion -resistant flashings shall be installed at all of the following locations: 1. Exterior window and door openings. Flashing at exterior window and door openings shall extend to the surface ot he exterior wall finish or to the water -resistive barrier for subsequent drainage. Flashing at exterior window and door openings shall be installed in accordance with one or more of the following or other approved method: 1.1 The fenestration manufacturer's written flashing instructions. 1.2 The flashing manufacturer's written installation instructions. 1.3 In accordance with FMA/AAMA 100, FMA/AAMA 200, or FMA/WDMA 250. 1.4 In accordance with the flashing method of a registered design professional. 2. At the intersection of chimneys or other masonry construction with frame or stucco walls, with projecting lips on both sides under stucco copings. 3. Under and at the ends of masonry, wood or metal copings and sills. 4. Continuously above all projecting wood trim. 5. Where exterior porches, decks or stairs attach to a wall or floor assembly of wood -frame construction. 6. At wall and roof intersections. 7. At built-in gutters. R703.6.2.1 Weep Screeds A Minimum 0.019-inch (No. 26 Gaiv. sheet gage), corrosion -resistant weep screed or plastic weep screed, with a minimum vertical attachment flange of 3 1/2" shall be provided at or below the foundation plate line on exterior stud walls in accordance with ASTM C 926. SELF -ADHERED FLASHING PRODUCTS DETAILS TWO LAYERS OF FELT OR ONE LAYER OF HOUSE WRAP AND ONE LAYER OF FELT ARE REQUIRED BEHIND STUCCO. FBC R703.2.1 Detail Instructions Refer to the number marked as (Din each detail that corresponds to the numbered items in the list of instructions below: 1. Install self -adhered flashing in order as shown by numbers 2. Install flashing and weather resistive barrier to form water shedding laps 3. Self -adhered flashing can be substituted for building paper 4. Split the release paper using the ripcord (Split release on demand, embedded in the adhesive layer) - for ease of installation and to minimize scoring cuts 5. Remove all release paper per standard installation instructions and adhere to substrate using a square piece of flashing material (6" x 6" Minimum) 6. Fold as shown by arrows 7. Angle of corner may vary, adjust folding of the flashing accordingly to fit tight to corner 8. Mechanically fasten as necessary Cement Plaster in accordance with ASTMC926 over wood 2nd floor Cement Plaster over block 1 st floor 7/8" Cement Plaster in accordance with ASTMC926 Felt backed metal lathe in accordance with ASTMC1063 Building Paper -7/16" O.S.B. sheathing Metal Flashing Weep Screed Installed As Per Manufact. Specs. Maintain Bottom of Weep Screed 1 1/2" to 2" Above Roof Sheathing 00-- Note: The building paper and metal lath must be installed over the top of the weep screed. WEEP SCREED DETAIL NOT USED NOT USED NOT USED e SC7,F: NOT TO SCALE 7/8" Cement Plaster in accordance with ASTMC926 Felt backed metal lathe in accordance with ASTMC 1063 Building Paper 7/16" O.S.B. sheathing Stampede or similar Cau k bottom joint only Weep Screed Installed As Per Manufact. Specs. 1/2" Cementitious Decorative Finish All inside and outside corner will need to be miter cut and caulked all butt joints need to becaulked using Stampede or sim. caulk for all CIA N� Z CD Z CO Z < I CL Z CD Q) a-) 4-J LLJ U 0 LU E 0 U*) Cn 0 M M C) c1d W Cl) LU E 0 0 0) Cl) C cc co 2 'S cc,) 0 0 W C) U_ 00 C) (D a) U5 C1. 8 0 e 0 < tM q CL 0) < A RFD1, N-C-B D-C If r-- - C:> cia M C14 LO G Cn C14 V, "o - Ln rL 0- C'J cl 10; - C5 6 00 Z M 1A Z 1-. c'v' _J W 4qF P- c) T 3 a: - 0 �J 0 06 04 r .'� U U� Lu M LU U .2 0 < 6­5 Z 0 a (n 0) 3 < 9 .0 C. 0 CO M Z E �; 2 01-9-1 S CN < _J W < = co 'E of El 1:1 To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the Florida Building Code 5th Edition (2014) Residential. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. C:) C:) Z rJ 0 Q) r-, 1­4 4-J C) V) , F3 �,o CD > U.) ro C:) P__I r0 - r-, 4-J U-) fu U-) < Z a- V) (n 2: (V 0 F-� CL CID Z < LEL, Q� U CD_ 00 < . %..., Z M F- WLU _J C:) mi 0, � 5� ?: LU Z 8 0, 0, Z Z Z W Z 0 Lu C/) 8 �2,2 _J Lu Z uJ U) Z Z >, 8 Ln LLJ X Z Z< Z 0 -0 LL 43: Ln 0 0 0 20 U I= > 0 UJ ILI fo 0Z < V i-1: 00 2 M- 0 Lq a LU Z < 3: Lu ,� X 0 b 9 c� Z :1- 2 Z CY 2: �j LU Lr) "o < W, 5 8 6i 2: < Z 0 0*1 Z W W I Z < �e Z Z = < Cy V) M Z 0 M 0 LIJ Z LU rn I T-4 SCALE AS NOTED DATE 2/24/2014 TECH: MIAMES VERSION No' 10 SHEET NO. W P -6-1 (3) a) c- C/) (3) USP Connectors > < Cross Reference > (3) 0 USP Florida Statewide Evaluation Report Simpson Florida Statewide Evaluation Report 0- C) L_ Stock No. Product Approval No. Basis Stock No. Product Approval No. Basis co -0 n- A3 F L 17244.1 ESR-3455 A23 FL10446.2 ESR-2606 (D (3) HD210-2 FL17232.3 ESR-3445 HU210-2 FL10655.20 ESR-2549 0 C/) = -cu ch HD212-2 FL17232.3 ESR-3445 HU212-2 FL`10655�23 ESR-2549 (3) -a FL1 7232.3 0 HD216 ESR-3445 HU216 FL10655.29 ESR-2549 0 HD216-3 FL17232.3 ESR-3445 0 -0 HU216-3 FL10655.29 ESR-2549 PRODUCT APPROVAL SPECIFICATION SHEET HD26 FL17232.2 ESR-3445 HU26 FL10655.31 ESR-2549 As required by Florida Statute 553.842 and Florida Administrative Code 9B-72, please provide the information and approval numbers on the building components listed below if 0 HD28-2 I'Ll 7232.3 ESR-3445 they will be utilized on the construction project for which you are applying for a building permit. We recommend you contact your local product supplier should you not know the 0 %4- HU28-2 FL10655.34 ESR-2549 product approval number for any of the applicable listed products. U) M C) > HU410 FL10655.44 ESR-2549 E L_ HD410 FL17232.4 ESR-3445 0 HD412 FL1 7232.4 ESR-3445 HU412 FL10655.45 ESR-2549 Cl) L_ Category/Subcategory Manufacturer Product Description Approval Number(s) Test Pressures CU HD610 FL1 7232.4 ESR-3445 !E c/) %+2) CU HU610 FL10656.51 ESR-2549 1. EXTERIOR DOORS Cn < HD0410 FL1 7241.5 ESR-3444 HUCQ410 FL11468.11 SIM200804 +67.0/-67.0 HGA110KT FL17236.6 ESR-3448 HGA10KT I'Ll 1470.4 SIM200803 A. SWINGING ThermaTru Smooth -Star and Benchmark FL15225.5 psf HGAM10KT FL17699.1 Evaluation Report HGAMIOKT FL1 1470.4 SIM200803 ThermaTru Premium, Construction Series and Benchmark FL15225.6 +47.0/-47.0 psf HHCP2 FL17236.7 ESR-3448 HCP2 FL10447.2 ESR-2551 ThermaTru Fiber Classic I Smooth Star FL15000.1 +55.0/-55.0 psf HTA16 FL17680.2 Evaluation Report HETA16 FL1 1473.5 SIM200802 B. SLIDING General Aluminum Company Series 4201430 FL1 5332.1 - I'Ll 5332,5 +40.0/-40.0 psf HTA20-18 FL17680.2 Evaluation Report HETA20 FL1 1473.5 SIM200802 C. SECTIONAL Clopay Building Products Residential WinclCode Doors W5 (8X7) FL15279,37 +30.0/-32.0 psf HTT16 FL17324.1 Evaluation Report HTT16 FL11496.1 ES-0130 Clopay Building Products Residential WindCode Door's W5 (16X7) FL15279.53 +30,0/-30.0 psf HTT45 FL17324.1 Evaluation Report HTT22 FL1 1496.1 ES-0130 Clopay Building Products Residential WndCode Doors W6 (8X7) FL15279.85 +38.0/-42.0 psf HTT4 FL17219.2 ER-0200 HTS16 FL10456.22 ESR-2613 Clopay Building Products Residential WindCode Doors W6 (16X7) FL15279.102 +37.0/-41.0 psf HTTS FL17219.2 ER-0200 HTS20 FL10456,23 ESR-2613 D. METAL LOUVERED DRS Curries Division of AADG, Inc 607,707,727,747,and 847 Single & Pairs of Doors I'Ll 1537.1 N/A (see inst sht) HTW16 FL17244.8 ESR-3455 HTS24 FL10456.24 ESR-2613 HTW20 FL17244.8 ESR-3455 HTS30 FL10456.26 ESR-2613 2. WINDOWS HTW24 FL17244.8 ESR-3455 HTSM16 FLI 1473.11 SIM200802 A. SINGLE HUNG General Aluminum Company Series 1550/1570 FL15217.4 - FL15217.5 +50.0/-55.0 psf HTW30 FL17244.8 ESR-3455 HTSM20 FL11473.11 SIM200802 General Aluminum Company Series 1900/1970 FLI 5217.7 - FL15217.9 +40.0/-50.0 psf HTWM16 FL6223.2 Evaluation Report HGT2___ FL10456.18 ESR-2613 B. HORIZONTAL SLIDER General Aluminum Company Series 1580/1590 FL15288.1 - FLI 5288.2 +40.0/-50.0 psf HTWM20 FL6223.2 Evaluation Report HGT3 FL10456.19 ESR-2613 General Aluminum Company Series 1980/1990 FL1 5288.3 - FLI 5288.4 +40.0/-50.0 psf HUGT2 FL6223.3 Evaluation Report HUS210-2 FL10655.92 ESR-2549 C. FIXED General Aluminum Company Series 1550/1570 FL15278.4 - FL15278,5 +40.0/-40.0 psf HUGT3 FL6223.3 Evaluation Report HUS212-2 FL10655.93 ESR-2549 General Aluminum Company Series 1900/1970 FL15278.7 - FL15278.9 +40.0/-50.0 psf HUS210-2 FL17232.7 ESR-3445 HUS26 FL10655.94 ESR-2549 D. MULLION General Aluminum Company 1445, 5347 and 5547 Vertical Mullion FL1 5333.7 N/A HUS212-2 FL1 7232.7 ESR-3445 HUS28 FL10655.96 ESR-2549 E. OTHER HUS26 FL17232.7 ESR-3445 HUS28-2 FL10655.97 ESR-2549 HUS28 FL1 7232.7 ESR-3445 LU24 FL10655.103 ESR-2549 3. PANEL WALL HUS28-2 FL17232.7 ESR-3445 LU26 FL10655.104 ESR-2649 A. SIDING James Hardie Building Prod. Cemplank Lap Siding and HardiePlank Lap Siding FL13192.1 - FL13192.2 NIA JL24 FL17232.8 ESR-3445 LUS210-2 FL10655.107 ESR-2549 B� SOFFITS Alside Solid and Vented Soffit FL15272.1 - FL15272.2 +70.0/-70.0 psf W JL26 FL17232.8 ESR-3445 LUS24 FL10656.109 ESR-2549 JUS210-2 FL17232.12 ESR-3445 LUS26 FL10655.1 11 ESR-2549 C. OTHER JUS24 FL17232.11 ESR-3445 LUS26-2 FL10655.112 ESR-2549 JUS26 I'Ll 7232.12 ESR-3445 LUS28 FL10655.113 ESR-2549 4. ROOFING PRODUCTS JUS26-2 I'Ll 7232.12 ESR-3445 LUS46 FLI 0655.118 ESR-2549 A. ASPHALT SHINGLES Certain Teed Corporation CT20 (and AR), Landmark 30/40 (and AR), FL5444.1 N/A JUS28 I'Ll 7232.12 ESR-3445 LEG3 FLI0667.71 ESR-2615 XT25 (and AR), XT30 (and AR) B. UNDERLAYMENTS Tamko 151b Felt Underlayment FL12328.6 N/A JUS46 FL17232.12 ESR-3445 MST60 FLI0852.7 ESR-2105 KLEG3 FL17241.15 ESR-3444 LSTA12 FL10852.4 ESR-2105 HomeGuard Building Products, Inc ToughSkin Synthethic Underfayments FL21675.1 N/A KST260 FL1 7244.15 ESR-3455 LSTA15 FL10852.4 ESR-2105 C. ROOFING FASTENERS NOT USED LSTA12 FL17244.18 ESR-3455 LSTA18 FLI0852.4 ESR-2105 D, ROOF VENTILATORS Thompson Arch Metal Comp. Off Ridge Vents FL5219.1 - FL5219.3 N/A LSTA15 FL17244,18 ESR-3455 LSTA24 FL10852.4 ESR-2105 Florida Metal Products, Inc Vent RV 0 FL2075.1 N/A LSTA18 FL17244.118 ESR-3455 LSTA30 FL10852.4 ESR-2105 Lomanco, Inc DA-4 Exahust Vent FL1 7202.1 N/A LSTA24 FL17244.18 ESR-3455 LSTA36 FL10852.5 ESR-2105 O'Hagin Manufacturing, LLC O'Hagin's Cloakded Vent Tile FL16588.1 N/A LSTA30 FL17244.18 ESR-3455 LTT19 FL1 1496,3 ER-130 E. ROOFING TILES Boral Tile Villa 900 FL7849.24 - FL7849.26 N/A LSTA36 FL17244.18 ESR-3455 LTT20B I'Ll 1496.3 ER-130 BoralTile Saxony 900 FL7849.13 - FL7849.16 NIA LTS19 FL17219.3 ER-0200 LTT131 I'Ll 1496.3 ER-130 F. OTHER LTS20B FL1 7219.3 ER-0200 LTS12 FL10456.29 ESR-2613 5. SHUTTERS LTT131 FL1 7219.3 ER-0200 LGT2 FL1 1470.7 SIM200803 A. STORM PANELS Global Protection Products Galvanized -Steel Storm Panels FL1 5076.1 - FLI 5076.2 N/A LTW12 FL1 7244.8 ESR-3455 LS30 FL10446.15 ESR-2606 Global Protection Products GPP Fabric Shutter Series 2000 FL15088.1 N/A LUGT2 I'Ll 7240.2 ESR-3447 A34 FL10446.3 ESR-2606 Town and Country Industries Safety Edge Storm Panels FL12856.1 +54.0/-54.0 psf MP3 FL17244.22 ESR-3455 LTP4 FL10446.19 ESR-2606 All American Shutters Galvanized Steel Storm Panels FL17869.1 N/A MP34 FL17244.23 ESR-3455 LS50 FL10446.16 ESR-2606 6.STRUCTURAL MP4F FL17244.24 ESR-3455 WM1416 FL10667.86 ESR-2615 COMPONENTS MP5 FL17244.22 ESR-3455 MSTA12 FL10852.8 ESR-2105 A. WOOD CONNECTORS/ USP Structural Conn. see chart MPH3516 FL1 7240.3 ESR-3447 MSTA15 FL10852.8 ESR-2105 ANCHORS Simpson Strong -Tie see chart MSTA12 I'l-172408 ESR-3455 MSTA18 FL10852.9 ESR-2105 B. TRUSS PLATES ITW Building Components Alpine Truss Plates I'Ll 999.1 - FL1999.4 N/A MSTA15 FL17244.18 ESR-3455 MSTA24 FL10852.9 ESR-2105_____ MiTek Industries, Inc. Truss Plates FL2197.1 - FL2197.5 NIA MSTA18 FL17244.18 ESR-3455 MSTA36 FL10852.9 ESR-2105 C. ENGINEERED LUMBER Boise Eng. Wood Prod. Versa -Lam SP FL1644.1 N/A MSTA24 FL17244,18 ESR-3455 MSTC40 FL10852.11 ESR-2105 MSTA36 FL17244.18 ESR-3455 MSTC52 FL10852.11 ESR-2105 Boise Eng. Wood Prod. Wood I-JoistsALLJOIST FL1645.1 N/A MSTC40 FL17244.26 ESR-3455 MTS12 FL10456.33 ESR-2613 Weyerhaeuser Engineered lumber - TJI FL1630.1 - FL1630.11 N/A MSTC52 FL17244.26 ESR-3455 MTS16 FL10456.34 ESR-2613 Weyerhaeuser iLevel Rim Board, LVL, PSL, LSL FL6527.1 - FL6527.4 N/A MTW12 FL17244.8 ESR-3455 MTS18 FL10456.35 ESR-2613 D. MATERIAL Cast -Crete Corp. High Strength Concrete Lintels FL158,1 N/A MTW16 FL1 7244.8 ESR-3455 MTS20 FL10456.36 ESR-2613 Commercial Concrete Products, Inc. High Strength Concrete Lintels FL1 774 N/A MTW18 FL17244.8 ESR-3455 MGT FLI 1470.9 SIM200803 Powers Steel, Inc. PSbox8LT, PSbox8LT(5-5/8) FL5450.1 N/A MTW20 FL17244.8 ESR-3455 MBHA3.56/11.25 FL10866.12 ESR-2616 Powers Steel, Inc. PowerBOX8 Lintels FLI 1383.1 N/A The products listed below did not demonstrate product approval at plan review, I understand that at the time of inspection of these products, the following information must be MUGT15 FL1 7240.5 ESR-3447 MBHA3.56/16 FL10866.12 ESR-2616 available to the inspector on the jobsite; 1) copy of the product approval, 2) the performance characteristics which the product was tested and certified to comply with, 3) copy of NFM35X12 FL578.2 Evaluation Report HDU2-SOS2.5 FL10441.4 ESR-2330 the applicable manufacturers installation requirements, Further, I understand these products may have to be removed if approval cannot be demonstrated during inspection. NFM35Xl6U FL578.3 Evaluation Report GLTV3.51 6 FL10667.8 ESR-2615 PAU44 FL17239.13 ESR-3449 FGTR FL 11473.2 SIM200802 PAU66 FL17239.13 ESR-3449 CS16 FL10852.1 ESR-2105 PHD2A FL1 7219.4 ER-0200 H1 FL10456.5 ESR-2613 PHXU3516 FL17241.20 ESR-3444 HIO FL10456.6 ESR-2613 RFUS FL6223.5 Evaluation Report H10-2 FL10456.7 ESR-2613 E 4­0 RS150 FL17244.27 ESR-3455 HIOA FL10456.6 ESR-2613 RT15 FL17236.11 ESR-3448 H3 FL10456.13 ESR-2613 (D R71 6-2 FL17236.10 ESR-3448 H4 FL10456.14 ESR-2613 APPLICANT SIGNATURE DATE RT16A FL17236.10 ESR-3448 H5 FL10456.15 ESR-2613 RT3A FL17236.11 ESR-3448 H2.5 FL10456.11 ESR-2613 RT4 FL17236.11 ESR-3448 H2.5A FL10456.12 ESR-2613 RT5 FL1 7236.11 ESR-3448 H8 I'Ll 1470.3 SIM200803 co > RT7 FL1 7236.11 ESR-3448 SPI FL10456.41 ESR-2613 0 RT7A FL1 7236.11 ESR-3448 SP2 FLIG456.42 ESR-2613 RT8A FLI 7236.11 ESR-3448 SP4 FL10456.43 ESR-2613 > SPT22 FL1 7244.30 ESR-3455 SP6 FL10456.44 ESR-2613 SPT24 FL1 7244.31 ESR-3455 SP8 FL10456.45 ESR-2613 0 SPT4 FL17244.32 ESR-3455 SPH4 FL10456.46 ESR-2613 SPT6 FL17244.32 ESR-3455 SPH6 FL10456.47 ESR-2613 SPT8 FL17244.32 ESR-3455 SPH8 FL10456.48 ESR-2613 SPTH4 FL17244.32 ESR-3455 U24 FL10655.141 ESR-2549 0 SPTH6 FL17244.32 ESR-3455 HHUS28-2 FL10655.3 ESR-2549 L_ SPTH8 FL17244.32 ESR-3455 HHUS410 FL10655.4 ESR-2549 0- SUH24 FL17232.14 ESR-3445 HGUS5.25/12 FL1 1468.11 SIM200804 THD28 FL17232.17 ESR-3445 HGUS414 FL 11468.10 SIM200804 THD28-2 FL17232.17 ESR-3445 HDQ8-SDS3 FL10441.1 ESR-2330 TH041 0 FL17232.17 ESR-3445 MSTAM24 FL1 1473.19 SIM200802 M THD412 FL17232.17 ESR-3445 MSTAM36 FL1 1473.19 SIM200802 THD612 FL17232.17 ESR-3445 MSTCM40 FLI 1473.19 SIM200802 < THDH414 FL17232.18 ESR-3445 HHETA20 FLI 1473.9 SIM200802 UGTS3F FL2033.1 Evaluation Report LGT3-SDS2.5 FL1 1470.7 SIM200803 UPHD8 I'Ll 7219.6 ER-0200 LGUM26-2 I'Ll 1473.12 SIM200802 LU < _J a. SHE T NO PA 1 . 0 a) Cn -Z5 a) > 2 C)-2 cL o C: Co -0 Florida Department of Business & Professional Regulation Page i of 2 Florida Department of Business & Professional Regulation Page I of I - .4-0 Building Codes and Standards 1/9/2017 Building Codes and Standards 1/9/2017 CU -C'a ch Florida Department of Business & Professional Regulation Page 1 of 2 (1) 0 Product Approval Application Detail Product Approval Application Detail Building Codes and Standards 1/9/2017 c 2 Product Approval Application Detail -2 0 CL = 0 FM5225-R3 FL#15000-R C 0 LL_ Code Entity o Date Date Date Pending Date Code Entity or Date 2& Date Pendino FL#15332-R3 Products C M = ,- 0 co Type Versio Manufacturer Contact Engineer & License Validated By Validated Submitted FBC Approval Approved Status T­ Verslo Manufacture Contact Engineer & License Validated By Validated Submitted FBC Approval Approved Status CD 0 > Revision 2014 Therma-Tru Corporation RickWright National Accreditation & Ryan J. King, P.E. 06/28/2015 06/13/2015 07105/2015 Approved Revision 2014 Therma-Tru Corporation RickWright Lyndon F. Schmidt, P,E. Ryan J. King, P.E. 06/28/2015 05/29/2015 07/05/2015 08119/2015 Approved Quality Assurance Approved for Use Approved for Use Impact Design 0 Category: Exterior Doors (419) 298-1740 Management I nstitute (813) 767-6555 Category: Exterior Doors (419) 298-1740 PE-43409 (813) 787-6555 Seq # Product Model, Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure L_ D_ Subcategory: Swinging Exterior Door Assemblies rickyv@rvvbldgconsultants. Subcategory: Swinging Exterior Door Assemblies rick�A@rwbidgconsultants. 4 SERIES 420 ALUMINUM SGD REINFORCED SERIES 420 ALUMINUM SGD REINFORCED OX, 12/31/2017 No Yes No N/A Cn Compliance Method: Certification Mark or Listing oom Compliance Method: Evaluation Report from a com XO, XX 96&quot;x96&quot; C_ 40-- co 0- Florida Registered Architect or a Licensed Florida 5 SERIES 420 ALUMINUM SGD REINFORCED SERIES420 ALUMINUM SGD REINFORCED XXX 12/3112017 No Yes No NIA FL#1 5225-R3 Prod ucts Professional Engineer 143&quot;x96&quot; 7 SERIES 420 REINFORCED ALUMINUM SGD SERIES 420 REINFORCED ALUMINUM SGD OXO 1213112017 No Yes No NIA Quality Assurance Approved for Use Approved for Use Impact Desion 146&quot;x96&quot; Seq # Product Model, Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure FL#15000-R2 Products 8 SERIES 430/440 ALUMINUM SGD SERIES 430/440 ALUMINUM SGD XXX 12/31/2017 No Yes No N/A 5 e. &quot;Smooth-Star&quot and &quot Benchmark by 6/8 and 8/0 Opaque and Glazed Fiberglass Door with 12/31/2021 No Yes No N/A Quality Assurance Approved for Use Approved for Us Impact Design 143&quot;x8O&quot; NON -REINFORCED Therma-Tru&quot and withoutSidelites. Inswing and Outswing seq # Product Model, Number or Name Product DescriDtion Contract ExDiration Date in HVHZ Outside HVHZ Resistant Pressure 9 SERIES 4301440 REINFORCED ALUMINUM SGD SERIES 430/440 REINFORCED ALUMINUM SGD 12/3112017 No yes No N/A 6 f. &quot; Premium Series&quot;, &quot; Construction 6/8 and 810 Opaque and Glazed Steel Door with 12/31/2021 No Yes No N/A 1 a. &quotFiber-Classic&quot or &quotSmocth-Star&quot; 6&#39,8 &quot;Non-Impact&quot, Opaque Fiberglass 1213112018 Yes Yes No N/A XXX 143&quot;x96&quot Series&quot; and &quot.Benchmark byTherma-Tru&quot; Transoms. With and withoutSidelites. Inswing and Door with &amp; without Sidelite(s) - Outswing (X OX with Transoms OutsWng or X0, OXO, XX, OXXO Configurations) Z Florida Department of Business & Professional Regulation Page I of I Z Building Codes and Standards 1/912017 Florida Department of Business & Professional Regulation Page I of 2 Product Approval Application Detail Florida Department of Business & Professional Regulation Page I of 1 Building Codes and Standards 1/9/2017 W FL#15279-R4 Building Codes and Standards 1/10/2017 Product Approval Application Detail Code Versio Entity o Date Date Date Pend ino Date Product Approval Application Detail IM Manufacture Contact Enaineer & License Validated Validated Submitted FBC Approval Approved Status FL#15217-R4 Revision �014 Clopay Building Products Company Mark Westerfield I ntertelk Testing Services NA, Gary Pfuehler 06/12/2015 03/19/2015 06/21/2015 Approved FL#11537-R6 Code Entity or Date Date Date Pending Date TVDe Versio Manufacture Contact Eno ineer & License Validated By Validated Submitted FBC Approval Approved Status Category: Exterior Doors Subcategory: Sectional Exterior Door Assemblies (513) 770-6062 Inc, (513) 519-6566 mvvesterfield@clopay.com Code Entity or Date Date Date Pending Date Revision 2014 MI Windows and Doors Brent Sitlinger Luis Roberto Lomas Steven M, Urich, PE 0613012015 06125/2015 07/06/2015 08/19/2015 Approved Compliance Method: Certification Mark or Listing T-e yj= Manufacturer Contact Enaineer & License Validated By Validated Submitted FBC Avoroval Anoroved Status Category: Windows (717) 365-3300 PE-62514 (717) 317-8454 Revision 2014 CURRIES Division of AADG, Inc Nelson Kraschel UL LLC Ted Berman, PE 07/21/2015 07121/2015 07/27/2015 Approved Subcategory: Single Hung bsitinger@miM.com FL#15279-R4 Products Category: Exterior Doors (841) 423-1334 (305) 868-4707 Compliance Method: Evaluation Report from a SubCategory: Exterior Door Components nelson.kraschel@doorgro Florida Registered Architect or a Licensed Florida Quality Assurance Approved for Use Approved for Us Im pa Desion Compliance Method: Certification Mark or Listing up.corn Professional Engineer Seq # Product Model, Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure 37 037 W5-09 PAN-21`1 51: 84A, 94, 73. 75� 1500,190, 76, Steel Pan (min. 25 ga.) Single -Car (up to 9'0" wide) 05/21/2028 No Yes No +30 PSF/-32 FL#1 1537-R6 Prod ucts FL#15217.R4 Products 76V, 4RST, 4RSF, 6RST, 6RSF, 2RST, 48, 42, 55, 48B, WINDCODE&#1 74, W5 Garage Door PSF Quality Assurance Approved for Use Approved for Use Im pact Desion Quality Assurance Aolproved for Use Aimroved for Use Impact Design 42B, 55S, GD5S, G05SV, GR5S, GR5SV, AR5S, AR5SV, Seg # Product Model. Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure seq # Product Model, Numberor Name Pr-oduct Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure ED5S,ED5SV 1 607, 707, 727, 747, and 847 Single and Pairs of Doors Flush, Glazed, and Louvered single and pairs of 12/31/2017 Yes Yes Yes N/A 4 SERIES GA 195 ALUMINUM SH SERIES GA 195 ALUMINUM SH N1 44X84 12J31/2017 No Yes No N/A hollow metal doors 5 SERIES GA 195 ALUMINUM SH SERIES GA 195 ALUMINUM SH NI 54)(72 12/31/2017 No Yes No N/A 53 053 W5-16 PAN-21`153: 84A, 94, 73, 75,1500,190, 4RST, Steel Pan (min. 25 ga.) Double -Car (9'2" to 16'0" 05121/2028 No Yes No +30 PSFI-30 2 M, CM, and G Series Frames Three sided and four sided single and pairs of 1213112017 Yes Yes Yes N/A 7 SERIES GA 195 ALUMINUM SH SERIES GA 195 ALUMINUM SH NI 54X72 12131/2017 No Yes No N/A 4RSF, 6RST, 6RSF, 48, 42, 55, 4813, 42B, 55S, G D5S, Wde) WINDCODE&#1 74; W5 Garage Door PSF frames. Tansorn frames. 8 SERIES GA 195 ALUMINUM TRIPLE SH SERIES GA 195 ALUMINUM TRIPLE SH NI l2t3l/2017 No Yes No N/A GD5SV, GR5S, GR5SV, AR5S, AR5SV, ED5S, ED5SV CONTINUOUS HEAD AND SILL 108)C72 NON 85 085 W6-09 PAN-21`1 53: 73, 75, 84A. 94. 42, 48, 42B, 48B, Steel Pan (min. 25 ga.) Single -Car (up to 9'0" wide) 05/21/2028 No Yes No +38 PSF/-42 9 SERIES GA 195 ALUMINUM TWIN SH IMPACT SERIES GA 195 ALUMINUM TWIN SH NI 12131/2017 No Yes No N/A 4RST, 6RST, GD5S, GR5S, AR5S, ED5S VVINDCODE&#174, W6 Garage Door PSF CONTINUOUS HEAD AND SILL 88 1/8)(72 102 102 W6-1 6 PAN-21`153: 73� 75, 84A, 94, 42, 48, 426, 48B, Steel Pan (min. 25 ga.) Double -Car (97 to 16'2" 05/21/2028 No Yes No +37 PSFf-41 4RST, 6RST, GD5S, GR5S, AR5S, ED5S wde) WINDCODE&#174. W6 Garage Door PSF cz Florida Department of Business & Professional Regulation Page 1 of 3 Florida Department of Business & Professional Regulation Page i of i Building Codes and Standards 1/9/2017 Building Codes and Standards 1/9/2017 Product Approval Application Detail Florida Department of Business & Professional Regulation Page 1 of 1 0 Building Codes and Standards 1/9/2017 Product Approval Application Detail FL#15278-R4 Product Approval Application Detail FL#15268-R2 Code Entity o Date Date Date Pendina Date co Code Entity or Date Date Date Pending Date DRe Versio Manufacturer Contact Engineer & Licens Validated By Validated Submitted FBC Approval Approved Status FL#15333-R2 IY2_e EEk Manufacture Contact Engineer & License Validated By Validated Submitted FBC Approval Approved Status Revision 2014 MI Windows and Doors Brent Sitlinger Luis Roberto Lomas Steven M. Urich, PE 09101t2015 08/31/2015 09/05f2015 10/16/2015 Approved Affirmation 2014 MI Windows and Doors Brent Sibinger Luis Roberto Lomas Steven M. Urich, PE 04/3012015 04/3=015 05/1012015 Approved Category: Windows (717) 365-3300 PE-62514 (717) 317-8454 Code Tvoe Versio Manufacture Entity o Contact Enaineer & License Validated By Date Date Validated Submitted Date Pending FBC Approval Date Approved Status Category: Windows (717) 365-3300 PE-62514 (717) 317-8454 Subcategory: Fixed Compliance Method: Evaluation Report from a bsitinger@miwd.com Revision 2014 MI Windows and Doors Brent Sitlinger Luis Roberto Lomas Steven M. Unch, PE 06/29/2015 06/19/2015 07/0512015 08/1912015 Approved SubCategory: Horizontal Slider bsitinger@miM.com Florida Registered Architect or a Licensed Florida Category: Winclows. (717) 365-3300 PE-62514 (717) 317-8454 Compliance Method: Evaluation Reportfrorn a Florida Registered Architect or a Licensed Florida Professional Engineer Subcategory: Mullions bsitinger@mMd.com Professional Engineer FL#15278-R4 Products Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida FL#1 5288-R2 Prod ucts Quality Assurance Approved for Use Approved for Use Impact Desion Professional Engineer Quality Assurance Approved for Use Approyed for Use Impact Design Sea # Product Model, Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure, FL#15333-R2 Products Seg # Product Model, Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure 4 SERIES GA 195 ALUMINUM PW SERIES GA 195 ALUMINUM PWN196X48 FIN 12131/2017 No Yes No NIA I SERIES GA 198 ALUMINUM HORIZONTAL SLIDER SERIES GA 198 ALUMINUM HORIZONTAL SLIDER 12/31/2017 No Yes No N/A 5 SERIES GA 195 ALUMINUM PW SERIES GA 195 ALUMINUM PWN172X72 12131/2017 No Yes No N/A Quality Assurance Approved for Use Approved for Use Impact Deslan 72X54 FLANGE Seg # Product Model. Number or Name Product Descriotion Contract Expiration Date! in HVHZ Outside HVHZ Resistant Pressure < 2 SERIES GA 198 ALUMINUM HORIZONTAL SLIDER SERIES GA 198 ALUMINUM HORIZONTAL SLIDER 12/3112017 No Yes No N/A 7 SERIES GA 196 ALUMINUM PW SERIES GA 195 ALUMINUM PWN196X48 12t3l/2017 No Yes No N/A 7 1445,5347 AND 5547 VERTICAL MULLION 1445,5347 AND 5547 VERTICAL MULLION 12/31/2017 No Yes Yes N/A 72X54 FLANGE 3 SERIES GA 198 ALUMINUM XOX HORIZONTAL SLIDER SERIES GA 198 ALUMINUM XOX HORIZONTAL 12/31/2017 No Yes No N/A 8 SERIES GA 275 THERMALLY BROKEN ALUMINUM PW SERIES GA 275 THERM ALLY BROKEN ALUMINUM 12131/2017 No Yes No N/A SLIDER 108X48 9 SERIES GA 505 ALUMINUM PW PW NI 72X72 FIN SERIES GA 505 ALUMINUM PWNl72X72 FIN 12131/2017 No Yes No N/A CD 4 SERIES GA 198 ALUMINUM XOX HORIZONTAL SLIDER SERIES GA 198 ALUMINUM XOX HORIZONTAL 12131/2017 No Yes No N/A SLIDER 0 co 0 CL CIO -0 0 i Florida Department of Business & Professional Regulation Page I of 2 Florida Department of Business & Professional Regulation Page 1 of I Florida Department of Business Professional Regulation Page 1 of 2 Cn Building Codes and Standards 1/9/2017 Building Codes and Standards 1/9/2017 Building Codes and Standards 1/9/2017 Product Approval Application Detail Product Approval Application Detail Product Approval Application Detail U) ICU FLM3192-R4 FL#15272-Ri FL#5444-R10 M Code Type Versio Manufacturer Entity o Contact Eno ineer & License Validated By Date Date Validated Submitted Date Pending FBC Approval Date Approved Status Code Type M2LQ Manufacturer Entity o Contact Enaineer & Licens Validated By Date Date Date Pendina Validated Submitted FBC Approval Data Aporoved Statu Code Tylpe Versio Manufacture Entity o Contact Enalneer & License Validated By Date We Validated Submitted Date Pendina FBC Approval Date Approved Status Revision 2014 James Hardie Building Products, Inc. Pingsheng Zhu Ronald 1. Ogawa John Southard, P.E. 08/2612015 08/1712015 09107f2015 10/16/2015 Approved Revision 2014 Alsicle NickThompson Lyndon F. Schmidt. P.E. Ryan J. King� P.E. 02/23/2015 02/1 9r`2015 03/0112015 04/15/2015 Approved Revision 2014 CertainTeed Corporation -Roofing Mark Hamer Robert Nieminen John W. Knezevich, PE 12/14/2016 12/08/2016 12/15/2016 Pending FBC Approval Category: Panel Walls (909) 349-2927 PE-24121 (352) 367-2526 Category: Panel Walls (330) 922-2389 PE-43409 (813) 767-6555 Category: Roofing (610) 851-6847 PE-591 66 (954) 772-6224 Subcategory: Siding pingsheng.zhu@jameshar Subcategory: Soffits nthompson@alside.com Subcategory: Asphalt Shingles markd.harner@saint-gob Compliance Method: Evaluation Report from a die.00m Compliance Method: Evaluation Report from a Compliance Method: Evaluation Report from a ain.com Florida Registered Architect or a Licensed Florida Florida Registered Architect or a Licensed Florida Florida Registered Architect or a Licensed Florida Professional Engineer . Professional Engineer Professional Engineer ICU -FL#13192-R4 Prod ucts FL#15272-Rl Products FL#5444-RIO Prod ucts Uj Quality Assurance Approved for Use Aipproved for Use Impact Desion Product Model. Name Qualily Assurance Product Contract Expiration Date Approved for Use Approved for Use in HVHZ Outside HVHZ Impact Resistant Design Pressure Approved Sea # Product Model, Number or Name Product Description Contract ExDiration Date in HVHZ Outside HVHZ Resistant Pressure Secl # Number or Description Quality Assurance for Use Appromad for Use Im Pact Design 1 Cemplank Lap Siding fiber -cement lap siding 01/01/2018 Yes Yes N/A N/A 1 a. &quot,2T&quot Soffit Vent or Solid Vinyl Soffit 12t3112018 No Yes No NIA Sea # Product Model, Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure 2 HardiePlank Lap Siding fiber-oement lap siding 01/01/2018 Yes Yes N/A N/A 2 b. &quot�Alliance T4&quot, Soffit Vent or Solid Vinyl Soffit 12t3l/2018 No Yes No N/A 1 CertainTeed Asphalt Roofing Shingles 3-tab, 4-tab, strip (no -cut-outs), laminated and 07/03t2017 No Yes NIA NIA architectural asphalt roof shingles Z IL SHEET NO. PA 1.1 T 4.� C_ —00 > IF- 2 CL 0 Florida Department of Business & Professional Regulation Page I of I CL L_ Building Codes and Standards 1/9/2017 r) Florida Department of Business & Professional Regulation Pagel of 3 Florida Department of Business & Professional Regulation Page I of 1 ai Building Codes and Standards 1/9/2017 Building Codes and Standards 2/6/2017 Product Approval Application Detail U) CO —CE3 — =3 C/) Product Approval Application Detail Product Approval Application Detail FL#5219-R3 (1) -0 0 0 0 116- FL#12328-R7 Products Code Entity or Date Date Date Pending Date 0 C:) = C) Quality Assurance Approved for Use Approved for Use Im pact Desion FL#21675-RO TvDe versio Manufacture Contact Engineer & License Validated By Validated Submitted FBC Aoproval Approved Status C) LL sea # Product Model, Number or Name Product Description Contract Expiration Date In HVHZ Outside HVHZ Resistant Pressure Code Entity 0 Date Date Date Pendin;t Date Revision 2014 Thompson Architectural Metals Company, Inc. Scott Brown James L. Buckner Steven M. Urich, PE 05/01/2015 04/29/2015 05/10/2015 06/2312015 Approved ca -4� %4- ICU 6 No. 15 UL Asphalt saturated organic fell 01/0712019 No Yes N/A N/A Type Majig Manufacture Contact Eno ineer & License Validated By Validated Submitted FBC Approval Approved Status 1 Category: Roofing SubCategory: Roofing Accessories that (813) 248-3456 PE-31242 (717) 317-8454 flvalidation@yahoo.com 0 Co 0 > New 2014 HomeGuard Building Products, Inc. John Cheslak Intertek Testing Services NA, IntertekTesting Services 02tOl/2017 01/2512017 02/03/20 17 are an Integral Part at the Roofing System U) — -0 E OL_ Approved Compliance Method: Evaluation Report from a w U) (1) L_ -6-a CD Category: Roofing (904) 240-1382 Inc. NA, Inc. Florida Registered Architect or a Licensed Florida Cn Co - Search Criteria Subcategory: Underiayments john.chestak@hgwap.co (604) 520-3321 Professional Engineer CD 110- Compliance Method: Evaluation Report from a m FL#5219-R3 Products < Code Version: 2014 FIL M. 12328 Product Evaluation Entity Application Type: ALL Product Manufacturer: ALL FL#21675-RO Products Quality Assurance Approved for Use Approved for Use Impact Design Category: ALL Subcategory: ALL SeQ # Product Model. Number or Name Product Description Contract Exviration Date in HVHZ Outside HVHZ Resistant Pressure Application Status: ALL Compliance Method: ALL Quality Assurance Approved for Use Aot)roved for Use Impact Desion 1 1 - &quotFlat Top Off Ridge Vent with Baffle for Tiie&quot; Minimum 26 Gauge Steel, Nominal 4&#39;, 6&#391, 12131/2019 No Yes No N/A Quality Assurance Entity Contract Expired: ALL Product Model, Number or Name: ALL Sao # Product Model, Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure 8&#39;, or 10&#39; Wide Off Ridge Vent Attached to Product Description: ALL Approved for use in HVHZ: ALL 1 ToughSkin Synthetic Underlayments ToughSkin 15, ToughSkin 20, ToughSkin 25, 01/01/2018 No Yes NIA N/A Wood Deck ToughSkin 30, ToughSkin 50 2 2- &quotRound Top Off Ridge Vent with Baffle for Minimum 26 Gauge Steel, Nominal 4&#39;, 6&#39;, 12/31/2019 No Yes No N/A Approved for use outside HVHZ: ALL Impact Resistant: ALL Tile&quot; 8M39;, or 10&#39, Wide Off Ridge Vent Attached to Design Pressure: ALL Date From: ALL Wood Deck Date To: ALL 3 3- &quotStandard Off Ridge Vent with Permanent Baffle Minimum 26 Gauge Steel, Nominal 4&#39, 6&#39;, 12/3112019 No Yes No NIA for Shingles&quot 8&#39;, or 10&#39; Wide Off Ridge Vent Xttch.d to Wood Deck Z Z Florida Department of Business & Professional Regulation Page I of I Florida Department of Business & Professional Regulation Page 1 of 1 Building Codes and Standards VIN2017 Florida Department of Business & Professional Regulation Page I of 1 LU Building Codes and Standards 1/9/2017 Product Approval Application Detail Building Codes and Standards 1/10t2017 Product Approval Application Detail Product Approval Application Detail FL#17202-RI FL#2075-R7 Code Entity or Date Date Date Pending Date FL#16588-RI Code Entity o Date Date Date Pending Date U22. Versio Manufacture Contact Enaineer & License Validated By Validated Submitted FBC Ai3proval Approved Status Type ylc§12 Manufacture Contact Engineer & License Validated By Validated Submitted FBC Approval Aooroved Status Revision 2014 Lomanco, Inc AndrewCarter James L. Buckner, P.E. Steven M. Urch, PE 05/01/2015 05/01/2015 05/10/2015 06/M2015 Approved Code Entity o Date Date Date Pend inn Date Affirmation 2014 Florida Metal Products Inc. Clark Jones Miami -Dade BCCO - EVL Miami -Dade BCCO - VAL 02127/2015 02t27/2015 03/09/2015 Approved Category: Roofing (501) 982-6511 PE-31242 (717) 317-8454 Tvpe Verslo Manufacturer Contact Encilneer & License Validated By Validated Submitted FBC Approval Api)roved status SubCategory: Roofing Accessories that are an acarter@lomanco.com Affirmation 2014 O'Hagin Manufacturing, LLC Gregory Daniels Miami -Dade BCCO - CER Ted Berman, PE 06/17/2015 06/17/2015 06/2512015 Approved Category: Roofing SubCategory., Roofing Accessories that are an (904) 783-8400 (786) 315-2590 clark@flamco.com Integral Part of the Roofing System Category: Roofing (707) 872-3620 (305) 868-4707 Integral Part of the Roofing System Compliance Method: Evaluation Report from a SubCategory: Roofing Accessories that are an gdaniels@ohagin.com Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Integral Part of the Roofing System Product Evaluation Entity Professional Engineer Compliance Method: Certification Mark or Listing FL#2075-R7 Products FL#17202-Rl Products FL#16588-Ri Products Quality Assurance Approved for Use Approved for Use Impact Desion Quality Assurance Approved for Use Approved for Use Impact Desian Quality Assurance Approved for Use Approved for Use Impact Design Seq Product Model, Number or Nam Product Description Contract Expiration Date In HVHZ Outside HVHZ Resistant Pressure Sea 0 Prod uct Model. Number or Name Product Description Contract Expilration Date in HVHZ Outside HVHZ Resistant Pressure Seq # Product Model, Number or Name Product Description Contract Expiration Date In HVHZ Outside HVHZ Resistant Pressure I RV1 0 RVIC ALUMINUM RIDGE VENT 01/3112018 Yes Yes N/A INIA 1 Deck -Air- DA-4 Low Profile, Polypropylene Plastic, Roof Vent 07/10/2019 No Yes No +97.5/-97.5 1 0&#39,Hagin&#39;s Cloaked Vent Tile Attic Ventilation Product for tile roofing applications 04/04/2018 Yes Yes NIA NIA Mechanically Attached to Plywood Deck, 2 OmniRdge&#1 74; PRO Vent PR04-N Molded Plastic, Roof Ridge Vent Mechanically 07/10/2019 No Yes No +NIAJ-165 Attached to OSB or Plywood Deck. Cn CU (D Florida Department of Business & Professional Regulation Page I of 1 Building Codes and Standards 1/9/2017 Product Approval Application Detail FL#15076-R3 C: Florida Department of Business & Professional Regulation Pagel of 3 Building Codes and Standards 1/9/2017 code Entity o Date Date Date Pending Date TVPe Versio Manufacture Contact Engineer & License Validated By Validated Submitted FBC Aovroval Approved Status 0 Product Approval Application Detail Revision 2014 Global Protection Products, LLC. Tim Robinson Walter A. Tillit Jr., P.E. John W. Knezevich, PE 05106/2015 04/24/2015 05/11/2015 06/23/2015 Approved Florida Department of Business & Professional Regulation Page 1 of 1 Category: Shutters (954) 689-7545 PE-44167 (954) 772-6224 Building Codes and Standards 1/9/2017 Subcategory: Storm Panels tim.robinson@gppent.com FL#7849-R9 Compliance Method: Evaluation Report from a Product Approval Application Detail Florida Registered Architect or a Licensed Florida Code Entity o Date Date Date Pend ling Date Professional Engineer Type ygaj2 Manufacturer Contact Engineer & License Validated By Validated Submitted FBC Approval Approved Status FL#1507rR3 Products FL#15088-Rl Revision 2014 Boral Roofing Monierl-ifetile Thomas Jemmett ICC Evaluation Service. LLC Gary W. Walker 09/1012015 08/25/2015 09/2012015 Approved Category: Roofing (602) 269-2288 (205) &54-0160 Quality Assurance Aooroved for Use Approved for Use I m pact Deslan Code Entity o Date Date Date Pend ino Data SubCategory: Roofing Tiles thomas.jemmett@boral.co Sea # Product Model, Nurn Oer or Nam a Product Description Contract Expiration Date in HVHZ Outside HVHZ Resista Pressur TvPe Versio Manufacture Contact Engineer& Licens Validated By Validated Submitted FBC Approval Approved Status Compliance Method: Evaluation Report from a m 1 20 Gage Galvanized Steel Storm Panels/HVHZ Corrugated Galvanized Steel Storm Panels retained 12/3112017 Yes Yes Yes N/A Revision 2014 Global Protection Products, ULC. Tim Robinson Walter A. Ti lit Jr,, P. E. John W. Knezevich, PE 04/27t2015 04/24/2015 05103/2015 06/23/2015 Approved Product Evaluation Entity or not by tracks to provide hurricane protection. Category: Shutters (954) 689-7545 PE-44167 (954) 772-6224 2 24 Gage Galvanized Steel Storm Panels/NHVHZ Corrugated Galvanized Steel Storm Panels retained 12131/2017 No Yes Yes N/A Subcategory: Fabric Storm Panel tim.robinson@gppent.com FL#7849-R9 Products or not by tracks to provide hurricane protection. Compliance Method: Evaluation Report from a Quality Assurance Approved for Use Approved for Us Impact Design Florida Registered Architect or a Licensed Florida Professional Engineer seq # Product Model, Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure FL#15076-R4 13 Saxony 700 - Shake, Slate &amp Split Shake Flat Profile - Stockton 12131/2018 No Yes NIA N/A Code Type jjMj2 Manufacturer Entity o Contact Enaineer & License Validated By Date Date Date Pendina Validated Submitted FBC Approval Date! Approved Status, FL#15088-RI Products Quality Assurance Avproved for Use Approved for Us Impact Design 14 15 Saxony 900 - Country Slate, Shal�e &amp; Slate Saxony 900 - Country Slate, Shake, Slate &arrip, Split Flay Profile - Henderson 12/31/2018 Flat Profile - Lake Wales 12t3l/2018 No No Yes Yes N/A N/A N/A N/A Revision 2014 Global Protection Products, ULC. Tim Robinson Walter A. Tillit Jr., P. E. John W. Knezovich, PE 12/2112016 1212112016 Validated Seg # Product Model. Number or Name Product Descriotion Contract Ex0ration Date in HVHZ Outside HVHZ Resistant Pressure Shake Category: Shutters (954) 689-7545 PE-44167 (954) 772-6224 1 GPP FABRIC SHUTTER -SERIES 2000 Coated Polyethylene Fabric Panels retained by tracks 12/31/2017 No Yes Yes N/A 16 Saxony 900 - Hartford Slate, Split Old English Thatch. Flat Profile - Stockton 12/31/2018 No Yes NIA N/A SubCategory: Storm Panels tim.robinson@gppent.com or direct mounted to provide hurricane protection. 24 Shake, Slate, Country Slate Villa 900 Medium Profile - Lake Wales 12/3112018 No Yes NIA N/A Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida (D 25 Villa 900 Medium Profile - Denver 12/3112018 No Yes N/A N/A Professional Engineer (D 26 Villa 900 Medium Profile - Stockton l2t3l/2018 No Yes N/A N/A FL#1507 -R4 Products Quality Assurance Acioroved for Use Anproved for Use Im pact Deslan S_ # Product Model, Number or Name Product Description Contract Expiration Date In HVHZ Outside HVHZ Resistant Pressure U) 1 20 Gage Galvanized Steel Storm PaneistHVHZ Corrugated Galvanized Steel Storm Panels retained 12/31/2017 Yes Yes Yes NIA or not by tracks to provide hurricane protection. 0 2 24 Gage Galvanized Steel Storm PanelsINHVHZ Corrugated Galvanized Steel Storm Panels retained 12131/2017 or not by tracks to provide hurricane protection. No Yes Yes N/A > 0 CL (D CL Cu Florida Department of Business & Professional Regulation Page 1 of I 0 Building Codes and Standards 1/9/2017 _§__j L_ Florida Department of Business & Professional Regulation Page I of 2 Florida Department of Business & Professional Regulation Page 1 of I Cn 0- Product Approval Application Detail Building Codes and Standards 119t2017 Building Codes and Standards 1/9/2017 (D FL#12856-R5 Product Approval Application Detail Product Approval Application Detail C/) code Entity or Date Date Date Pending Date CIO Type Manufacture Contact Enoineer & License Validated By Validated Submitted FBC Approval Approved Statu FL#17869-RO FL#1999-R5 Revision 2014 Town and Country Industries, Tom Johnston Frank 1. Bennardo ORLANDO L. BLANCO, 04/2912015 04/28/2015 05/04/2015 06/22t2015 Approved Category: Shutters SubCategory: Storm Panels (954) 493-8551 PE-0046549 P.E. tomj@tc-alum.com (305) 510-8531 Code T-0 Versio Manufacture gntity or Contact Engineer & License Validated By Date Date Date Pend ina Validated Submitted FBC Approval Date Approved Status Code Type Versio Manufacturer Entity or Contact Enaineer & License Validated By Date Date Validated Submitted Date Pending FBC Apg)roval Date Approved Status Compliance Method: Evaluation Report from a New 2014 All American Shutters and Glass Mike Barbieri Frank L. Bennardo, RE Jorge A. Pomerantz, P.E. 07103/2015 07/0312015 07/1012015 08/18/2015 Approved Revision 2014 ITW Building Components Group Inc. Paslode Stuart Lewis ICC Evaluation Service, LLC William M. Ranieri, PE 03/2512015 03/2012015 O3t29/2015 Approved Florida Registered Architect or a Licensed Florida Category: Shutters (561) 712-9882 PE-0046549 (954) 394-8521 Category: Structural Components (847) 918-6473 (407) 681-1917 Professional Engineer SubCategory: Storm Panels mikeb@allamericanshufte SubCategory: Truss Plates sleMs@alpineitw.com FL#12856-R5 Products Compliance Method: Evaluation Report from a rs.com Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Product Evaluation Entity Quality Assurance Approved for Use Apo ved for Use HVHIZ Im nact Resistant Design Pressure Professional Engineer FL#1999-R5 Products seq # 1 Product Model, Number or Name 0.050&quot, Aluminum Storm Panel Product Descrintion Cont Expiration Date 0.050&quot; Aluminum Storm Panelwith Optional 12/31/2018 in HV`HZ No Outside Yes Yes N/A FL#17869-RO Products QualltV Assurance Approved for Use Approved for Use Impact Design Uj Clear Panels Quality Assurance Approved for Use Approved for Use Impact Desicin Sect # Product Model, Number or Name Product Description Contract Expiration Oat in HVHZ Outside HVHIZ Resistant Pressure 2 &quot;Safety Edge&quot; Storm Panels &quot;Safety Edge&quot; Storm Panels, 28ga 12131/2018 No Yes Yes +541-54 Said # Product Model, Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Tes Pressure �/A 1 ITW BCG Higher Strength (H &amp; S) Metal Connector Plate 12/31/2020 Yes Yes NIA N/A (0.0l8&quot;&quoQ Steel, 0.022&quot; Alum (Pert 22ga, 24ga Steel Panels 22ga, 24ga Steel Storm Panels 12/31/2017 No Yes 2 ITW BCG Hinge Plate Metal Connector Plate 12131/2020 Yes Yes NIA N/A and Non -Pert), Clear Polycarb (Full and Halt) 3 ITW BCG Trulox Metal Connector Plate 12/31/2020 Yes Yes N/A N/A 3 24ga Steel Storm Panel 24ga (0,0232&quot;) Steel Storm Panel with Optional 12t3l/2018 No Yes Yes +100/-100 4 ITW BCG Wave Metal Connector Plate 12t3l/2020 Yes Yes N/A N/A Clear Panels 4 Aluminum Hinged Storm Panel .050&quot; Aluminum Non -Porous Hinged Storm 12131/2018 Yes Yes Yes NIA Panel _j SHE T NO PA 1. 2 C_ -Fo Q) > 2 2 cL o CU -0 n Florida Department of Business & Professional Regulation Page I of 1 Florida Department of Business & Professional Regulation Page 1 of 1 -6-0 CD cf) Building Codes and Standards 119n0l 7 Building Codes and Standards 1/9f2017 Florida Department of Business & Professional Regulation Page 1 of 1 cu —cu C/5 Building Codes and Standards 1/9/2017 0 Product Approval Application Detail Product Approval Application Detail 2 Product Approval Application Detail -2 0 = FL#2197-R5 FL#1644-R4 —0 C) code Entity o Date Date Date Pend ina Date code Entity o Date Date Date Pend Ing Date FL#1645wR4 CIO 0 wz TVPe Versio Manufacture Contact Enaineer & License Validated By Validated Submitted FBC Aparoyal Approved Status T­ Versio Manufacture Contact Engineer & License Validated By Validated Submitted FBC Approval Approved Status Code Entity o Date Date Date Pend ino Date Co C) > Revision 2014 MiTek Industries, Inc. David Wert ICC Evaluation Service, LLC ICC Evaluation Service, 06/30/2015 G6/11/2015 07/05/2015 Approved Revision 2014 Boise Engineered Wood Products Robert Taylor ICC Evaluation Service, LLC APA - The Engineered 05127/2015 M06/2015 06/02/2015 Approved Type Versio Manufacturer Contact Engineer & License Validated By Validated Submitted FBC Approval Approved Status E cp 2 Category: Structural Components (314) 851-7480 LLC. Category: Structural Components (541) 826-0200 Wood Association Revision 2014 Boise Engineered Wood Products Robert Taylor ICC Evaluation Service, LLC APA - The Engineered 05127/2015 05/06/2015 06/02/2015 Approved U) L_ SubCategory: Truss Plates dwert@mii.com (205) 599-9800 Subcategory: Engineered Lumber roberttaylor@bc.com (253) 620-7467 Category: Structural Components (541) 828-0200 Wood Association J=_ In CU CL Compliance Method: Evaluation Report from a Compliance Method: Evaluation Report from a Subcategory: Engineered Lumber roberttaylor@bc.00m (253) 620-7467 '0 cu Product Evaluation Entity Product Evaluation Entity Compliance Method: Evaluation Report from a U) FL#2197-R5 Products FL#1644-R4 Products Product Evaluation Entity FL#1645-R4 Products Quality Assurance Approved for Use Approved for Use Impact Deslan Quality Assurance Approved for Use Approved for Use Impact Desion Sad # Product Model, Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure seq # Product Model, Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure Quality Assuran2e Approved for Use Approved for Us Impact Design 1 M18SHS 18 ga. super high strength truss connector plate 12/3112017 Yes Yes N/A N/A 1 Versa -Lam Laminated Veneer Lumber 01/01/2035 No Yes N/A NIA Sad # Product Model. Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure 2 Mil 16 16 ga. truss connector plate 12/3112017 Yes Yes N/A NIA 1 AJS Joists Wood &quot;l&quot; Joists 01/01/2035 No Yes N/A NIA 3 MT18HS 18 ga. high strength truss connector plate 12/31/2017 Yes Yes N/A N/A 4 MT20 20 ga. truss connector plate 12/3112017 Yes Yes N/A N/A 5 MT20HS 20 ga. high strength truss connector plate 12131/2017 Yes Yes N/A NIA Search Criteria Florida Department of Business & Professional Regulation Pagel of 1 Building Codes and Standards 1/9/2017 Product Approval Application Detail Florida Department of Business & Professional Regulation Page 1 of I Building Codes and Standards 1/9/2017 FL#6527-R6 Product Approval Application Detail Florida Department of Business & Professional Regulation Page 1 of 1 Code Entity o Date Date Date Pend inn Date Building Codes and Standards Type Versio Manufacturer Contact Engineer & License Validated By Validated Submitted FBC Approval Approved Status 1/9/2017 Revision 2014 Weyerhaeuser Jim Anderson ICC Evaluation Service, LLC James A, Rothman, P. E. 07/0612015 05/12f2015 07130/2015 Approved FL#i58-R7 W Category: Structural Components (253) 924-4084 (608) 839-1344 Product Approval Application Detail SubCategory: Engineered Lumber jim.anderson2@vveyerhae Code Entity or Date Date Date Pending Date Compliance Method: Evaluation Report from a user.com TVI)e Verslo Manufacture Contact Enclineer & License Validated By Validated Submitted FBC Approval Approved Status FL#1630-RS Product Evaluation Entity Revision 2014 CAST-CRETE USA, Inc. Craig Perrino Miami -Dade BCCO - CER Miami -Dade BCCO - VAL 03/16/2015 02/2412015 03118/2015 Approved FL#6527-RG Products Category: Structural Components (813) 621-4641 (786) 315-2590 Code Entity or Date Date Date Pending Date SubCategory: Products Introduced as a Result of cparrino@castcrete.com Type Versio Manufacture Contac Engineer & License Validated By Validated Submitted FBC Approval Approved status Quality Assurance Approved for Use Approved for Use Impact Deson New-rechnology Revision 2014 Weyerhaeuser Jim Anderson ICC Evaluation Service, ULC James A. Rothman, P.E. 07/06/2015 05/1212015 07/3012015 Approved secl # Product Model, Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure Compliance Method: Certification Mark or Listing Category: Structural Components (253) 924-4084 (608) 839-1344 1 iLevel Rim Board Structural Composite Lumber or Oriented Strand 03131/2017 No Yes N/A N/A FL#1 58-R7 Products SubCategory: Engineered Lumber Compliance Method: Evaluation Report from a jim.anderson2@weyerhae user.com 2 Microllam LVL board Rim Board Laminated Veneer Lumber 0313112017 No Yes N/A N/A Quality Assurance Approved for Use Approved for Use Impa Desion Product Evaluation Entity 3 Parallarn PSL Parallel Strand Lumber 03/31/2017 No Yes N/A NIA Sad # product Model, Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistant Pressure 4 TimberStrand LSL Laminated Strand Lumber 03/3112017 No Yes N/A N/A 1 High Strength Concrete Lintels 4, 6, 8, and 12 inch wide lintels 05/21/2016 Yes Yes N/A N/A FL#1630-RO Products Quality Assurance Approved for Us Approved for Use Impact Design FL#6527-R7 FL#158-R Seg Product Model, Number or Name Product Description Contract Expiration D in HVHZ Outside HVHZ Resistant Pressure Code Entity o Date Date Date Pending Date Code Entity or Date Date Date Pend Ina Date 1 TJI 110 Prefabricated Wood I -joist 03131/2017 No Yes N/A N/A Tvoe Versio Manufacture Contact Engineer & License Validated By Validated Submitted FBC Approval Aooroved Status Type 7ersio Manufacture Contact Engineer& License Validated By Validated Submitted FIBC Approval Approved Status 2 3 TJ1210 TJ1230 Prefabricated Wood I -joist 03/3112017 Prefabricated Wood I -joist 0313112017 No No Yes Yes N/A N/A N/A N/A Revision 2014 Weyerhaeuser Jim Anderson ICC Evaluation Service, LLC James A. Rothman, P.E. 10/3112016 10/25/2016 11/05/2016 Approved Revision 2014 CAST-CRETE USA, Inc. Craig Parrino Miami -Dade BCCO - CER Miami -Dade BCCO - VAL 05106/2016 04/29/2016 05/06f2016 Approved 4 TJ1360 Prefabricated Wood [-joist 03/31/2017 No Yes N/A N/A Category: Structural Components (253) 924-4084 (608) 839-1344 Category: Structural Components (813) 621-4641 (786) 315-2590 5 TJ1560 Prefabricated Wood I -joist 0313112017 No Yes N/A NIA SubCategory: Engineered Lumber jim.anderson2@weyerhae SubCategory: Products Introduced as a Result of cparrino@castcrete.com 6 TJI/560D Prefabricated Wood I -joist 03/3112017 No Yes N/A N/A Compliance Method: Evaluation Report from a user.com NewTechnology Product Evaluation Entity Compliance Method: Certification Mark or Listing FL#6527-R7 Products FL#158-R8 Products - Sea # Product Model, Number or Name Quality Assurance Product Description Contract Expiration Date Approved for Use Approved in HVHZ for Use Outside HVHZ Impact Resistant Design Pressure Seg # Product Model. Number or Name Quality Assurance Product Description Contract Expiration Date Approved for Use Approved in HVHZ for Use Outside HVHZ Impact Resistan Deskin Pressure 1 Mcrollam LVL Laminated Veneer Lumber 03131/2017 No Yes N/A N/A 1 High Strength Concrete Lintels 4, 6. 8, and 12 inch Wide lintels 05/21/2017 Yes Yes N/A N/A 2 Parallam PSL Parallel Strand Lumber 03/3112017 No Yes N/A N/A 3 TimberStrand LSIL Laminated Strand Lumber 03/31/2017 No Yes NIA N/A 4 TJ Rim Board Structural Composite Lumber or Oriented Strand 03/31/2017 No Yes N/A N/A board Rim Board 5 Weyerhaeuser Rim Board Oriented Strand Board Rim Board 03/31/2017 No Yes N/A N/A Florida Department of Business & Professional Regulation Page 1 of 1 Florida Department of Business & Professional Regulation Page 1 of 1 Building Codes and Standards 119r2017 Florida Department of Business & Professional Regulation Page 1 of 1 0 Building Codes and Standards 1/9/2017 Product Approval Application Detail Building Codes and Standards IW2017 IN Product Approval Application Detail Product Approval Application Detail FL#5450-R5 FL#1774-R4 Code Entity or Date 20 Date Pending Date FL#11383-114 TV100 Versio Manufacture Contact Enalneer & License Validated By Validated Submitted FBC Approval Approved Status Code Type Versio Manufacturer Entity or Contact Engineer & Licens Validated By Date Date Validated Submitted Date Pendina FBO Approval Date Approved Status Revision 2014 Powers Steel Inc. william powers Steven W. Schaub SAMUEL A. 03/26/2015 03123/2015 03130/2015 06/23/2015 Approved Code Tvpe Manufacturer, Entity or Contact Enaineer & License Validated By Date Date Validated Submitted Date Pending FOC Approval Date Approved Status Revision 2014 Commercial Concrete Products,inc. Robert Gillis TH UY H. HUYNH Florida Engineering 07/03/2015 06/24/2015 08/2012015 08/26/2015 Approved Category: Structural Components Subcategory; Products Introduced as a Result of (602) 437-1160 PE-60509 GREENBERG, P.E, bill@pavverssteel.com (813) 645-0166 Revision 2014 Powers Steel Inc. william powers Steven Schaub SAMUEL A. 03/26/2015 03/23/2015 03130/2015 06/22t2015 Approved Category: Structural Components (813) 659-3707 PE-60122 Solutions NewTechnology Category: Structural Components (602) 437-1160 PE-60509 GREENBERG, RE, SubCategory'. Products Introduced as a Result of precastgator@yahoo.com (352) 588-5311 Compliance Method: Evaluation Report from a Subcategory: Products Introduced as a Result of bill@powerssteel.com (813) 645-0166 NewTechnobgy Florida Registered Architect or a Licensed Florida NewTechnology Compliance Method: Evaluation Report from a Professional Engineer Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Florida Registered Architect or a Licensed Florida Professional Engineer FL#5450-R5 Products Professional Engineer FL#1774-R4 Products Quality Assurance Aoproved for Use Approved for Use Impact Design F L#i i 383-R4 Products Sao # Product Model, Number or Name Product Description Contract Expiration Date in HVHZ Outside HVHZ Resistan Pressure Quality Assurance Approved for Use Approved for Use Impact Design 1 PSbox8LT, PSboxBLT(5-5/8) Powers Steel lintels are field assembled lintels 01/27/2017 No Yes N/A N/A Quality Assurance Approved for Use Approved for Us impact Design Seg # Product Model, Number or Name Product Description Contract Expiration Date In HVHZ Outside HVHZ Resistant Pressure consisting of preformed steel lintels combined with §W Product Model, Number or Name Product Description Contract Expiration Date In HVHZ Outside HVHZ Resistan Pressure 1 Quality Precast or Commercial Concrete Products Precast and Prestressed Concrete Lintels 06/2512024 No Yes N/A NIA concrete masonry units, grout, and steel reinforcing 1 PowerBOX8 Lintels Powers Steel Lintqls are field assembled consisting 01/01/2017 No Yes N/A N/A bars. of preformed steel lintels combined with brick or concrete masonry units, grout, and steel reinforcing bars, (D If I= U) 0 0 "L (D 0 -0-0 0 -00 C/) M W Z z _J NO. SHEET PA 1. 11 A j 1A, I L -1, 1 �1 I 1 .1 1 1 111 1 i j' I I I i I I I - - - - - - - — - - — F—T, L /- lam J'4 6 ,,3 6/0 �,3),ih�