HomeMy WebLinkAbout6748 Gall Blvd (3)10 nl N v Co N d in o v N w 03 o� C) FLORIDIA HOSPITA Z PHYRHI S V NEti fz_" -URGE CAN S 12 "aks 1\4edical Office 113ixildirig 6748 Gall Boulevard Ze h rhills FL 335411 p Y PROJECT TEAM DIRECTORY SYMBOLS AND MATERIALS INDEX OF DRAWINGS NOTE: The symbols here are specific to the Architectural Drawings as a whole. A0.0 Cover Sheet The LJfe Safety, Reflected Ceiling Plan and Roof Plan respectively Include supplementary legends OWNERand drawing notes specific to those sheets. Refer to other disciplines for additional symbols. ARCHITECTURAL Florida Hospital Zephyrhills AO WINDOW TYPE � EARTH SP.I Site Plan 7050 Gall Boulevard � ELEVATION BENCHMARK GRANULAR FILL A1.0 A l I Life Safety Floor Plan Demolition Plan Zephyrhills, Florida 33541 0 REVISION AND NUMBER METAL , A2.0 Floor Plan Phone: (813) 788-0411 A2.1 Reflected Ceiling Plan C.J.D CONTROL JOINT ® FINISH WOOD A2.3 Finishes Plan A3.0 Enlarge Plans, Interior Elevations and Sections ARCHITECT DOOR AND FRAME WITH DOOR NUMBER STUCCO OR GYPSUM BOARD A5.0 Schedules and Details 0 ® CONCRETE OR GRAVEL Burt Hill / Pollock Krieg Architects, Inc. =zr/� EXISTING DOOR PLUMBING METAL STUD WALL CONCRETE MASONRY UNIT (CMU) 8250 College Parkway, Suite 203 MASONRY WALL PLYWOOD P0.1 Plumbing Spec's, Legend, Schedules and Drawing List Fort Myers Florida 33919 PLO Underground Plan - Demolition - Plumbing Phone: (239) 4 8 2 - 4 7 61 EVALUATION 208 � ROOM NAME AND NUMBER ACOUSTIC CEILING TILE P1.1 P2.0 First Floor Plan - Demolition - Plumbing Underground Plan -New Construction -Plumbing Please be advised this review of plans submitted is a cursory review to assist the contractor in compliance with ry p Fax: (239) 4 8 2 - 0 2 6 5 WALL TYPE ® BATT OR SEMI -RIGID INSULATION P2.1 First Floor Plan - New Construction - Plumbing applicable fire safety codes. This review is not intended to be a final approval of the submitted plans. It is the contractors sole responsibility to ensure that the plans are in BUILDING SECTION RIGID INSULATION complete compliun(;e with all applicable NFPA codes and local ordinances. In the event that further examination or SECTION OR DETAIL MECHANICAL site inspection reveals areas of non-compliance, it shall be MEPENGINEER 9' ELEVATION ROUGH WOOD FRAMING OR BLOCKING M0.1 HVAC Legend Schedules and Drawing Index the contractor's sole responsibility, at their sole expense to bring those areas in compliance. The Gity assumes no Smith Seickman Reid, Inc. ® INTERIOR ELEVATION M0.2 M0.3 HVAC Riser HVAC Specifications responsibility for the contractor's failure to be in compliance with all applicable NFPA Codes and local ordinances. Ta ALL 600 West Hillsboro, Suite 300 pLLW©RKgKALLCO OLRIDA6 VAI�,1NGCODMVL CCODEA M1.1 M2.1 First Floor Plan - Demolition - HVAC First Floor Plan -New Construction -HVAC Deerfield Beach Florida 343441 NORTH ARROW CODE, NATIONALELF O � � - q�!* i M5.1 HVAC Details Phone: (954) 421-1260 M5.2 HVAC Details Fax: (954) 421-1466 +"M=D PLANS M BEEN REVIEW OFF XT fi11'�_--% aY ZEPHYRHILL fS Date: — R-6+/'1i�wp FIRE PROTECTION Seal 5ke 71t 6 ? FPO.1 FPI.I Fire Protection Specs Legend Schedules and Drawing First Floor Index 4P 14k Plan - Demolition - Fire Protection VICINITY MAP FP2.1 First Floor Plan - New Construction - Fire Protection�dY P"�v��s FP5.1 Fire Protection Details ND S� )r?-e l ELECTRICAL E0.1 Electrical Legend, Schedules and Drawing Index �N E1.1 First Floor Plan - Demolition - Electrical Industry standards (I.e. ASTM, ANSI, etc.) SHALL HAVE THE SAME FORCE AND EFFECT E2.1 First Floor Plan -New Construction -Lighting on performance of work as If copies were directly Inserted Into the Contract Documents or bound and published therewith. Comply with standards In effect as of the date of the Contract Documents, t E3.1 First Floor Plan New Construction -Power & Systems y unless otherwise note or required by authorities having Jurisdiction. E4.1 Electrical Riser Diagrams E5.1 Electrical Specifications CODES All work shall conform to the following codes and ordinances: re>V -. 2007 Florlda Building Code, with 2009 amendments 2007 Florida Plumbing Code, with 2009 amendments 2007 Florida Fuel Gas Code, with 2009 amendments 2007 Florida Mechanical Code, with 2009 amendments - 2007 Florida Fire Prevention Code Local Codes and Ordinances where applicable and flood damage prevention ordinances 2006 NFPA 101 Life Safety Coae �°� z Project a � � f .met• �:..�.'� �= .. µz G Project No. 11006.00 AOOO 02011 BH/PK Architects, Inc. IMIA el-_ - MAN N 0 v- N 1R NI 9 t------------- - - - - -- . I I I I i -----------------------------------------------------------------------------------------------------------------------------------------------------------------------•------------------------------------------------J SITE PLAN NORTH I"=20'-0" �.11-ll Project No. 11006.00 SPM I ©2011 BH/PK Architects, Inc. C .r, /nnfr 07 nn 7n nil \..A\ ACn 1 e1 N 0 a- N ca � O N N =M 9 0 BUILDING CODE ANALYSIS i LIFE SAFETY PLAN Al.o lib • • l'-0• NORTH 1, Codes in effect: 5. Exit Calculations Permitted Proposed Florida Building Code 2007 Edition with 2009 ammendments NFPA 101 2006 Edition Max. Travel Distance: 300, 114'-0" Max. Dead End Corridor: 30, 2. Use and Occupancy Classification: Business Min. Corridor Width: 44" 60" As per FBC Chapter 3 and NFPA 101 Min. Clear Opening of Exit Doors: 32" 321, Exit Units 231, 224" J. Type of Construction: Type 111-B, Fully Sprinklered 6•. Interior Finish Requirements As per FBC Section 602 and NFPA 101 Table 8.1 Type 111 (2'0'0) As per FBC Table 803.5 4. Bui 1 d i ng Occupancy and NFPA 101 Table A 10.2.2 Bui 1 di ng Occupancy per FBC Table 1004.1.2 100/per sq.f t. Exits: Type A and NFPA 101 table 7.3.1.2 (in SF/Occupant): 11,224 SF Exit Access Corridors: Type A Allowed Occupancy 112 Rooms & Enclosed Spaces: Type A Renovation Area 2,074 SF SYMBOL LEGEND • F.E. FIRE EXTINGUISHER F.E.C. FIRE EXTINGUISHER CABINET M , MAGNETIC DOOR HOLDER SMOKE DETECTOR Q HEAT DETECTOR © FIRE ALARM PULL STATION STROBE DO HORN AND STROBE EXIT LIGHTS I M EXIT LIGHTS WITH DIRECTIONAL ARROW(s) 84' �Ozm EXIT WIDTH IN INCHES 125' :.�,,,,.............;;; ter'• INTERIOR EXIT PATH AND DISTANCE A SMOKE COMPARTMENT DESIGNATION Project No. 11006.00 A1,90 P i 1 r n ll l r, - n r 1. l l ,. 11 I I/ l 0.1 . r. l. ^ 1._ J__ r r .: �. ��, .., -d: ' .. �. ; ii�„�.r�� ... t'91LI � �OEIOIt'1'iS. 9& � 1,. ���llW� � �T r i;:,� a::f,,S.t ©2011 BHIPK Architects, Inc. a 7 O N b- rn o L ►2 00 a N er- N, �a r----------- I I I I I I I I I I I I I I I i I I I I I I I I Demolltlon Notes 1. Remove existing walls and doors shown dashed. 2. Remove all plumbing fixtures shown dashed cap plumbing at floor line. 3. Remove all flooring and base. 4. Remove all ceiling grid and tile. 5. Remove all A/C diffusers and light fixtures. Contractor to store for reinstallation. 6. Remove all counter tops. 7. Remove all abandoned wiring and duct work. 8. Contractor to protect all existing walls to remain. 9. Existing offices to remain in operation during construction. Contractor shall not block access to the building or the parking lot. 10. The shaded areas indicate floor cuts for plumbing ll. Remove all wall covering and wall paper borders �--------------------------------------------------' EXISTING VARIES EXISTING I I I I I I I I I I I I I I I I IE l I E 1=1 I EIII LL L=11 XIS I 12' long 05 dia at I 3,000 psi concrete 24' o.c. alternating sides I I on vapor barrier, compacted fill, with epoxy Into existing slab Align \ / I I I II I II I II I �I Remove existing doors, trim, etc. EXISTING i RENOVATION shown dashed Remove existing partitions, flooring, the door, trim, plumbing fixtures shown dashed, cap plumbing 1 DEMOLITION PLAN Al.l v8 • • P-0• Note: Retain all door being removed for reinstallation. ref inish as required J Project No. 11006.00 A to I © 2011 BH/PK Architects, Inc. --- r /ll /nnrl rI rn In 1II N �: - Y V &Ti 00 V N 1p co ----------------------------------- w/6x61011a w.w.f., concrete to have broom finish FLOOR PLAN NORTH A2.0 J 118 ' • 1'-0' Project No. 11006.00 A2.0 1 02011 BH/PK Architects, Inc. /rr Innrl In nn n1 n11 _ _I\ I n n r•-I__- =r- ;ai � 1 a . iT� , ,•� � v rr>a s.3 .� � `"t'`��•• r �" "�' 'i � '� - ~ I � � �"4'- �, I�i1. i, i. , r x ,'. .. .'. .'.t1..�. ..-i�'. N$'° ;r.'.�•�:-Lr' . I. 'cr-." r'""... i-r.. '� 'Gi r.K`F. :�� 14-,. i`+t� 11 ,�F-rpr,� CV f) J) z Cv N O NI 0 a- ti w QQ REFLECTED CEILING PLAN LEGEND LAY -IN PARABOLIC FLUORESCENT FIXTURE PRISMATIC LENS FLUORESCENT FIXTURE O 4 FOOT FLUORESCENT FIXTURE WALL MOUNTED FLUORESCENT FIXTURE PL—m—MI TRACK LIGHTS I— — -1 FLUORESCENT STRIP COVE LIGHTS E--0 FLUORESCENT STRIP UTILITY LIGHTS RECESSED LOW VOLTAGE DOWN LIGHT RECESSED WALL WASH DOWN LIGHT RECESSED OR SURFACE MOUNTED DOWN LIGHT -WP VAPOR PROOF RECESSED DOWN LIGHT CHANDELIER OR PENDANT FIXTURE 4 WALL SCONCE Q WP VAPOR PROOF WALL MOUNTED FIXTURE ® EXIT LIGHT WITH ARROW • SPRINKLER HEAD LINEAR SUPPLY DIFFUSER LINEAR RETURN REGISTER ® SUPPLY DIFFUSER ® RETURN REGISTER OR GRILLE CEILING FAN GYPSUM CEILING, SOFFIT OR BULKHEAD (provide closure at both sides as required) C.J. D CONTROL JOINT �Elev FINISH CEILING ELEVATION (A.F.F.) 8'-0' REFLECTED CEILING PLAN NOTES: 1. Refer to Electrical drawings for fixture types, counts and clrcuitJng. 2. Refer to Mechanical drawings for diffuser and register sizes. J. S)dewall registers, diffusers and sprinkler heads are not shown on Architectural reflected ceiling plans. 4. Coordinate locations of electrical, mechanical and fire protection devices with Architectural reflected ceiling plans. Repair existing ceiling as required nwiyn w,uny �n� I lighting as required In new Breeak area I --------------------------- I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I _, REFLECTED CEILING PLANNOR\ A2.1 118 ' • I'-O' Ceiling heights are 9'-2" a.f. .f . Project No. 11006.00 A201 ©2.011 N11/PK Architeck, Inc, N r--------- I I I I I I I I I I I I I I Match and extend flooring as required 1 I I I I I I I 1 I I I ----------------------------------------------------- Ls I I I I I I I I I I I I I I I I 14 --———— — — — — — � 0 a ----------- Cc � o N er- N e U W Phase 1 Phase 11 I I j O Existing Rworon Match and align plank flooring Work Ream i Match floo dn91 t) I EXlstll� I Caltrd I I 1 I I I — 1 I — I QM I C�o�� Exlsling X-Ray 1 Br kr000m I I I 1 1 I I — I I I L- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - L - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -� ♦ . Match, q d extend flooring FLOOR FINISHES PLAN In. new. Break area i 118 ' = 1'-0' i NORTH I 1 I I I I I I I I I I I I I I I Phase I , Phase ll I I O Repair match e) as regm !------------------------------------------------------------ I --- V Exam MechExP2 106 I I 103 I I 104 j I P2 PI I P11 I j Office I I 105 i I I MGR I Exam I I 101 l 102 � i \ Nurse I I -\ \ Elid I PI ark U I \ 107 I I I �• "---- PI--------------------------- Corridor -------- - 1 108 Existing Reception ----------I ----------------------- ------------, I I j PI — — I Ir_r — — - Aj llet I I 113 Storo e I Corrldorj j I � Exam I P Office 109 I 110 j Exam j I 112 I j 114 j I 111 j j ICI PI j I I I P2 I LP3 I I r------------ PI j Corridor j 115 L---------------------------------------I Existing Control Office 116 PI Work Room J— - — — - DYE I Dexo j Existing 117 118 I Existing X-Ray Closet I 1 I Breakr�oom — I I ---------------------------------------------------------------------------------------------------------------------------------------------------------------� Match existing Break room paint WALL FINISHES PLAN 1/8 ' = V-0" NORTH FLOOR FINISH SPECIFICATIONS Vinyl Plank Floor -6 x 36 Estrie Luxury 500 3293 Walnut 18 X 18 Vinyl floor ®Estrie - Bazaar 2135 Tollets Crossville Ceromlce Empire Series VS84 Laurel Green 14 x14 pollshed Grout to match the Carpet Monterey 56059 Zen Garden 00836 Vinyl Base Sillouette - Burke Colonial Base 4V4' Art Deco Brown 502- Contractor to use hospital stock WALL FINISH SPECIFICATIONS Paint PI - Match Color Wheel CL2921W Salt Marsh P2 - Sherwin Wlllams TIn Celling SWO091 P3 - Sherwin Williams Underseas SW6214 Paint Door frames P2 Stain door to match existing Plastic laminate Front and cabinets - Formica 6934-43 Mokko Figured Mohogony Counter top- Nevamar Lunaria Shadow LU6001T Transaction counter and accent squares - Corlon Matterhorn Cabinets Base cabinets - Formica 3504-58 Teal Solidz Counter tops - Nevamar Lunarlo Shadow LU6001T Wall the cl Crossville Ceromlce Empire Series 7 x 7 VS77 Porlsion White Refer to sheet A2.2 for locations Grout to match the Project No. 11006.00 I A202 l©2011 BH/PK Architects, Inc. cp CP N N _ o e r a N 0 N 0 � o a- N ca o v- N co 0 Gypsum board soffit L \— End panel rl NURSE WORK UP A3.0 114'•V-O' T CHECK-OUT A3.0 314 ' • 1'-0' 2 RECEPTION A3.0 114 ' = P-O' isticol Wall construction as J noted on the drawing Securely anchor cabinets to wall blocking (Typical) Adjustable shelve 5mm holes,) 114' o.c. with locking clips Note: Shim cabinets as requir by uneven wall, construct level and plumb Plastic laminate on 3/' plywood Wall construction as noted on the drawing Securely anchor cabinets Plastic laminate to wall blocking (Typlca.L on 3/' plywood Pull out keyboard troy 2 x wood blocking opening L: 3 RECEPTION A3.0 114 • • P-O' Suspended acoustical tie celling. Height as shown on Interior Elevations Plastic laminate closure panel 314' plywood construction Melamine covered Interiors, Plastic to mingle - Exteriors (Typical) Full overlay door cabinet design (2) hinges per door Size cabinets as shown and noted on the Drawings 4' high plastic laminote back and side splash sealed to wall with clear sealant 314' plywood countertop with 314' plywood built-up subbase plastic laminote on all exposed surfaces - - - - - - - iz Wire pulls, typical all cabinets Drawer bod :%' Melamine sides and bock; ' sub-frant: %4' Melomine housed bottom 314' plywood construction Melamine covered interiors, Plastic laminate - Exteriors (Typical) All base cabinets that require shelving ore to be metal standards with locking clips (Typical) Full overlay door cabinet design (2) hinges per door Shim cabinets as required by uneven wall and floor 4' toe space with base construction level and plumb a TYPICAL CABINET A3.0 314 • • P-o' ased opening etboard troy He drawers with etol hangers and Icks b tc to 1 4'-0' 1 2'-6' 1 Plastic laminate closure panel Soap dispenser Paper towel dispenser Pq Istic laminate sure panel 4 RECEPTION 5 EXAM 102, WAND 112 6 EXAM 103 AND 104 — rA3.0 114 ' = I'-O' A3.0 114 • = 1'-0' A3.0 114 • = P-O' 9 CABINET SECTION A3.0 314' - P-0' �o FILE CABINET A3.0 314' • P-0' 34' plywood countertop with 344' plywood built-up subbase plastic laminate on all exposed surfaces Wire pulls, typical all cabinets 314' plywood construction Melamine covered Interiors, tQ Plastic laminate - Exteriors N (Typical) Full overlay door cabinet design (2) hinges per door 4' toe space with base plywood countertop with a' plywood built-up subbase lostic laminate on all exposed urfoces 'rawer body: 518' Melamine sides nd back; 314' sub-frant: 14' Melamine housed bottom Wire pulls, typical all cabinets 314' plywood construction Melamine covered interiors, °lostic laminote - Exteriors (Typical) ull overlay door cabinet design ?) hinges per door toe space with base ' high plastic laminate bock and side splash sealed to the wall with clear sealant r_r /4' plywood countertop with /4' plywood built-up subbase plastic laminate on all exposed surfaces NOTE: Provide computer tray by Owner where noted (Typical) i ountertop broce,3 ' plywood with plastic laminate finish 7 provide as required and shown on elevation, moximum spacing 5'-0' unsupported length 7 WORK STATION A3.0 314 • • P-0' NOTE: 1. All framing and blocking in wall shall be non-combustible. Size and location as required by casework for secure support refer to sheet A3.0 for details. 2. All countertops shall be 3/' plywood and Y4' plywood with plastic laminate on exposed surface. Provide 2' radius on all exterior corners. Countertops back and side splashes to be edge banded. seal all Joints with clear silicone Joint sealer. J. Install 2' round plastic grommets, one to each work stations or located by owner. 4. Field verify size of all cabinets with room or wall length as required to fit within space, adjust cabinet lengths accordingly. 5. Shim cabinet as reuired by uneven wall and floor construction level and plumb. 6. All base cabinet that require shelving are to be metal standards with locking clips SEE P AIV Gypsum board & metal stud partition. See plan for partition type Anchoring device Fire Retardant 2x wood blocking secured to studs Secure metal plate to studs with%8' pop rivets or self topping pan head screws (min.three) 16go.6 In wide plate spanning 2 studs min. (typ) Metal studs WALL BLOCKING WALL REINFORCEMENT STEEL PLATE WALL REINFORCEMENT rl2 WALL REINFORCEMENT Grob bar; Toilet pop holder �3 TOILET ROOM A3.0 114 • • I'-O' Staff\ � Toilet 113 _ 7p dispenser 'ror )er towel penser and posal x 7 The Crossville 1romlcs VS77 Parisian Wte �\ Grab bars 7 x 7 The Crossville Ceramics VS77 Parisian _ White - - iA JToilet paperholder 3.0 y� 'n Thin set the on %' cementltlous 5'-It' file backer board with %' gypsum board above wainscot on existing gypsum board >'4 ENLARGE TOILET ROOM PLAN A�li4•-ro' ELEVATION A /5 ENLARGE TO A3.0 %4' = P-0' Project No. 11006.00 A3.0 r in 1 r)nrr in.rt. zn DI: t...ak A z n ©2011 Diin'K Architects, Inc. N o \ N LE 71 a- N o- N v n O 0 Q O a- N 00 IT N 0 ROOM DOT DENOTES FINISH LOCATION •• ® Nurse Work► ■�■■■■■ ■�■■■■■■■■■® ■ ®Stof f Tollet■■■0■■■ ■■0■ ��■■■ 0■■■ ' ®Corridor■�■■■■■ ■�■■ 0■■■■■■■� ■ DOOR SCHEDULE DOOR FRAME W O00 Q 02 W SIZE N W Z U ti W ti Q LQ V) W W Q W N DETAILS �z Q Oj =Q1) HEAD I JAMB THRSHLD 100 2'-0' x 7'-0' 1%' A WOOD STAIN A HM PAINT I/A5.0 1/A5.0 3 101 3'-0' x 9'-0' lY' A WOOD STAIN A HM PAINT 1/A5.0 1/A5.0 1 102 3'-0' x 9'-0' IY' A WOOD STAIN A HM PAINT I/A5.0 I/A5.0 103 3'-O' x 9'-0' 11' A WOOD STAIN A HM PAINT 1/A5.0 1/A5.0 104 3'-0' x 9'-0' lY4' A WOOD STAIN A HM PAINT I/A5.0 I/A5.0 105 3'-O' x 9'-0' lY' A WOOD STAIN A HM PAINT I/A5.0 I/A5.0 I 106 109 3'-0' x 9'-0' lY' A WOOD STAIN A HM PAINT I/A5.0 1/A5.0 I Ill 3'-0' x 9'-0' IYV A WOOD STAIN A HM PAINT I/A5.0 1/A5.0 - 112 3'-0' x 9'-0' 1%, A WOOD STAIN A HM PAINT 1/A5.0 I/A5.0 113 3'-O' x 9'-0' IY' A WOOD STAIN A HM PAINT 1/A5.0 I/A5.0 2 114 3'-0' x 9'-0' 1%' A WOOD STAIN A HM PAINT IIA5.0 I/A5.0 1 116 3'-0' x 9'-0' IY' A WOOD STAIN A HM PAINT I/A5.0 I/A5.0 1 117 3'-0' x 9'-0' 1%' A WOOD STAIN A HM PAINT 1/A5.0 I/A5.0 I 118 3'-O' x 9'-0' /3 ' A WOOD STAIN A HM PAINT I/A5.0 I/A5.0 I REMARKS I DOOR TYPES SCHEDULE REMARKS AND NOTES SCHEDULE REMARKS AND ABBREVIATIONS O MOISTURE RESISTANT GYPBOARD ON WET SIOE(S)OF WALLS. CONTRACTOR TO USE OWNERS EXISTING DOORS TO EXTENT 20 20 minute fire rated door, frame and hardware POSSIBLE. WHERE NOT POSSIBLE NEW DOORS WALL MATCH EXISTING. EXISTING DOORS TO BE STRIPPED, SANDED AND C Y/ hour 'C' label fire rated door, frame and hardware STAINED TO MATCH EXISTING. CONTRACTOR TO USE B 1 hour 'B' label fire rated door, frame and hardware EXISTING STOCK FRAMES WHERE POSSIBLE. FINISH TO MATCH EXISTING. WHERE NOT POSSIBLE CONTRACTOR ALUM Aluminum storefront system SHALL PROVIDE NEW FRAMES TO MATCH EXISTING. WALL TYPES HM Hollow metal frame Single layer YB' gypsum wallboard on each side of stud attached with I' type 'S' drywall screws - 3%' metal studs 0 1'-4' O.C. -� Acoustic attenuation or thermal insulation bott -� A % NON -RATED METAL FRAME TYPE A HEIGHT: Gypsum board extends to 4' obove finish ceiling unless otherwise noted. Single layer %' gypsum wallboard on each side of stud attached with 1' type 'S' drywall screws 6' metal studs M P-4' O.C. Acoustic attenuation or thermal Insulation bott B_> NON -RATED METAL FRAME HEIGHT: Gypsum board extends to 4' above finish ceiling unless otherwise noted. -%' cementiflous file backer board. Thinsef ceramic tile. Refer to finish schedule. 3%' galvanized metal studs 0 1'-4' O.C. %' gypsum wallboard, moisture resistant in wet conditions Acoustic attenuation or thermal insulation butt NON RATED METAL FRAME FOR TILE FINISH HEIGHT: If file does not extend full height of wall, backer board transitions to %' gypsum wallboard above wainscot. Gypsum board extends to 4' above finish ceiling unless otherwise noted. Refer to elevations and or finish schedule for height of tile. HARDWARE CONTRACTOR TO USE OWNERS EXISTING HARDWARE TO EXTENT POSSIBLE, WHERE NOT POSSIBLE USE HARDWARE LISTED BELOW HDW SET '1 HDW SET 02 Door •101, •105, *109. •114, •116. •117, •118 Door 1113, 4 eo Hinge BB1279 4-%2 x US26D 4 ea Hinge 881279 02 x US26D-Hager I eo Privacyset ND40SxRHOx626-Schloge I ea Lockset ND53PDxRHOx626-Schloge I ea Closer 146lxRW/PAx689-LCN I eo Wall stop 232WxUS32D-Hager I EA Wall stop 232WxUS32D 3 ea Silencer 307DxGREY-Hager 3 ea Silencer 307DxGREY HDW SET '3 Door •100 4 eo Hinge BB1279 02 x US26D I ea Lockset ND53PDxRHOx626 I ea Wall stop 232WxUS32D 3 ea Silencer J07DxGREY DOOR DETAILS �z"IC G SOILED CORE WOOD FLUSH FRAME TYPES HEAD HOLLOW METAL DETAIL A5.0 is ° V-0' HOLLOE METAL G Note: T _ �I These 8 studs II II III Metal runner and all connections channel 20go. min. II 1-411 MJ Metal stud H.M. frame 6 III I I II Jamb anchor 20go metal clips and spot - runner channel III (III grouting within III III h.m. frame Floor anchor clips II I I I I II Metal runner III III channel One layer %' gypsum wallboard each side of 3%' metal studs (refer to plans for wall types) Double studs Hollow metal frame l%' wood door One layer %' gypsum wallboard each side of J%' metal studs (refer to plans for wall types) Double studs Hollow metal frame Door refer to door schedule METAL STUDS FRAMING 2 @ DOOR OPENING %1Z Mj Project No. 11006.00 A5*0 )2011 BH/PK Architects, Inc. r -innll In .nn nr ,Ili %-_1%Arn r-i. l.,1-.-- 99��J ,.> .. '�` r ' �,, . �Y�,'. i t..' b � i V h j , � �?� it �-�'�ib x• �r l i j I �� *���, - I � -' r . PLUMBING SPECIFICATIONS PLUMBING DEMOLITION NOTES PLUMBING NEW CONSTRUCTION NOTES C 0 a- E D a 0 0 0 r` M i 0 N r` rn E 0 a) Li J LL z L U LI C Q v Ln 0 ;J REGULATORY REQUIREMENTS A. NFPA 101: Life Safety Code (2006). B. ANSI Handicapped Code-A117.1. C. Florida Fire Marshall's Rules 69A-3.012 F.A.C. - (2007). D. Florida Building Code - 2007 with 2009 ammendments. PLUMBING MATERIALS PLUMBING SYSTEMS SHALL BE INSTALLED IN ACCORDANCE WITH FLORIDA BUILDING CODE - PLUMBING 2007 AND ADA REQUIREMENTS. WASTE AND VENT: NO HUB SERVICE WEIGHT CAST IRON, BY CHARLOTTE, AB&I OR TYLER, CISPI STANDARD 301, ASTM A888. NSF ABOVE FLOOR WITH 'HUSKY' HEAVY DUTY *SD4000 COUPLINGS ASTM C1540 AND BELL AND SPIGOT WITH NEOPRENE GASKETS ASTM STANDARD C564 BELOW SLAB FOR PIPING 2' AND LARGER AND COPPER TYPE 'M' HARD DRAWN COPPER WITH WROUGHT FITTINGS, WITH 95/5 LEAD FREE SOLDER FOR PIPING UP TO 1-1/2'. CONDENSATE PIPING: COPPER TYPE 'M' WITH FOUGHT COPPER FITTINGS LEAD FREE SOLDERED JOINTS. CONDENSATE INSULATION:ARMAFLEX OR THERMACE�LL, 25/50 FIRE/ SMOKE RATING SEAL JOINTS WITH INSULATIOMFGR. ADHESIVE. LABEL PIPING AS INDICATED ABOVE. WATER: DOMESTIC COLD & HOT WATER PIPING SHALL BE TYPE 'L' HARD DRAWN COPPER WITH WROUGHT FITTINGS, WITH 95/5 LEAD FREE SOLDERED JOINTS PER FBC 2007. NSF-61. INSULATE HOT WATER PIPING USING 1' THICK FIBERGLASS INSULATION HAVING A FLAME SPREAD RATING OF 25 OR LESS AND A SMOKE DEVELOPMENT OF 50 OR LESS IN ACCORDANCE WITH ASTM E-84,NPFA 225 AND UL 723. ACCEPTABLE INSULATION MFGR'S: KNAUF, JOHNS-MANVILLE AND CERTAINTEED. FOAMGLASS INSULATION SHALL BE USED WHERE PIPING PENETRATES RATED WALLS. LABEL PIPING BY ADHESIVE LABELS (TO DENOTE CONTENTS AND DIRECTION OF FLOW) ON PIPING AT NO MORE THAN 25 FOOT INTERVALS, AT EACH VALVE, AND AT EACH CHANGE IN DIRECTION. PROVIDE ARROWS AT EACH LOCATION WHERE LABELED INDICATING DIRECTION OF FLOW. LABELING TO BE MINIMUM OF 2' HIGH LETTERS. LABEL PIPING BY ADHESIVE LABELS (TO DENOTE CONTENTS AND DIRECTION OF FLOW) ON PIPING AT NO MORE THAN 25 FOOT INTERVALS, AT EACH VALVE, AND AT EACH CHANGE IN DIRECTION. PROVIDE ARROWS AT EACH LOCATION WHERE LABELED INDICATING DIRECTION OF FLOW. LABELING TO BE MINIMUM OF 2' HIGH LETTERS. TEST WATER AND WASTE PIPING AS PER LOCAL CODES. WATER HEATER: LOCHINVAR, A.O.SMITH PLUMBING FIXTURES: KOHLER, AMERICAN STANDARD. ZURN. PLUMBING TRIM: CHICAGO FAUCET, ZURN STAINLESS STEEL SINK: ELKAY OR JUST SHOCK ARRESTORS: SIOUX CHIEF OR PRECISION PLUMBING PRODUCTS. FIXTURE CARRIER: ZURN, WADE, J.R. SMITH THERMOSTATIC MIXING VALVES: SYMMONS, POWERS. SUPPLY STOPS: McGUIRE OR ZURN HEAVY DUTY CONTRACTOR SHALL PROVIDE PLUMBING FIXTURE AND MATERIAL SUBMITTALS TO THE ENGINEER FOR APPROVAL PRIOR TO INSTALLATION AND PURCHASING. PLUMBING FIXTURES PROVIDE PLUMBING FIXTURES, TRIM AND RELATED ITEMS SUCH AS HEAVY DUTY SUPPLIES, TRAPS, DRAINS, CLEANOUTS AND FIXTURE SUPPORTS AND OTHER ACCESSORY ITEMS. COORDINATE FIXTURE REQUIREMENTS BY REVIEWING ARCHITECTURAL AND EQUIPMENT DRAWINGS. INSTALL FIXTURES IN ACCORDANCE WITH CONTRACT DRAWINGS AND MANUFACTURER'S ROUGH -IN DRAWINGS. WALL HUNG LAVATORIES SHALL BE PROVIDED WITH FLOOR MOUNTED CARRIERS. MATERIALS HANGERS - GRINNELL BY ANVIL, B-LINE, FEE AND MASON, PHD, VIKING AND RELIABLE. 1. GRINNELL FIGURE *CT-69, MSS TYPE 10 WITH ADJUSTABLE WROUGHT TUBING RING HANGER, COPPER PLATED FOR: NON -INSULATED COPPER TUBING WITH NO LONGITUDINAL MOVEMENT; NON -INSULATED CAST IRON PIPING 2' AND LESS. EXPANSION ANCHORS: HILTI KWIK-BOLT, ZINC PLATED, METAL EXPANSION ANCHOR TO BE USED ON EXISTING CONSTRUCTION. ANCHOR TO MEET U.L.. ICBO-4627 AND FM LISTINGS. VALVES - NIBCO, WATTS, KITZ OR MILWAUKEE 1. BALL VALVES (DOMESTIC WATER): A. 2' AND LESS: NIBCO FIGURE T-685-80-LF OR S-685-80-LF, 2-PIECE, FULL PORT, 600 PSI, WOG, TFE SEATS. NSF 61, LEAD FREE. B. PROVIDE EXTENDED LEVER FOR INSULATED SERVICE. 2. CHECK VALVES (DOMESTIC WATER): A. 2' AND LESS: NIBCO FIGURE T-433 OR S-433, THREADED OR SOLDERED, CLASS 150, NSF-61, LEAD FREE. 3. LOCATE VALVES SO AS TO BE ACCESSIBLE BY MAINTENANCE PERSONNEL. ALL MATERIAL SHALL BE DOMESTIC AND SHALL BE MANUFACTURED WITHIN THE UNITED STATES OF AMERICA. CLOSEOUT CONTRACTOR SHALL PROVIDE AS BUILT DRAWINGS IN AUTOCAD FORMAT AT COMPLETION OF PROJECT. 1. EXISTING SERVICES INDICATED ON THESE DRAWINGS WERE DERIVED FROM EXISTING DRAWINGS AND LIMITED FIELD OBSERVATIONS. THESE DRAWINGS MAY NOT BE ALL INCLUSIVE OF SERVICES THAT EXIST IN THE PROJECT AREA. CONTRACTOR SHALL VERIFY SERVICES, LOCATION, TYPE, AND SIZE PRIOR TO ANY CONSTRUCTION. ANY DEVIATIONS IMPACTING WORK SHOWN ON THESE DOCUMENTS SHALL BE REPORTED TO THE ARCHITECT FOR COORDINATION PRIOR TO CONSTRUCTION. 2. EXISTING SERVICES, EQUIPMENT, AND FIXTURES, TO REMAIN OR TO BE RELOCATED, SHALL BE REPAIRED TO ORIGINAL OPERATION OR REPLACED, SHOULD THEY BE DAMAGED DURING CONSTRUCTION. 3. ALL EXISTING WORK NOT SHOWN ON THESE DRAWINGS (UNLESS NOTED OTHERWISE) SHALL REMAIN AS IS. 4. ALL PENETRATIONS OR OPENINGS FROM REMOVED PIPES THROUGH EXISTING BUILDING WALLS AND FLOORS SHALL BE SLEEVED AND/OR PATCHED TO MATCH ORIGINAL. SEE ARCHITECTURAL DRAWINGS FOR FINAL FINISHES. 5. CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO EXISTING PIPING , FIXTURES OR EQUIPMENT DUE TO NEW CONSTRUCTION AND SHALL RESTORE EXISTING WORK TO ITS ORIGINAL CONDITION AT NO COST TO THE OWNER. 6• CONTINUITY OF SERVICES: EXISTING BUILDING WILL REMAIN IN USE DURING CONSTRUCTION OPERATIONS. WHEN AN INTERRUPTION OF AN EXISTING SERVICE IS NECESSARY, CONTRACTOR SHALL COORDINATE WITH AUTHORIZED MAINTENANCE PERSONNEL BEFORE MAKING THE NECESSARY INTERRUPTION. 7. CONTRACTOR TO REMOVE EXISTING STACKS AND RISERS LOCATED IN EXISTING WALLS TO BE DEMOLISHED AND PROVIDE NEW OFFSETS AT CEILING ABOVE AND CEILING BELOW TO NEW STACK OR RISER LOCATION COORDINATED WITH FLOOR PLAN LAYOUT AND EXISTING CONDITIONS. 8. CONTRACTOR TO FIELD VERIFY THAT ALL EXISTING PLUMBING TO BE REMOVED DOES NOT AFFECT OTHER AREA'S OF THE BUILDING THAT ARE NOT IN CONSTRUCTION AND MUST STAY OPERATIONAL. IF DISCREPANCIES ARE FOUND THE CONTRACTOR IS TO NOTIFY THE ENGINEER. 9' CONTRACTOR SHALL REMOVE EXISTING PLUMBING FIXTURES AND EQUIPMENT TO BE REMOVED AS SHOWN ON DRAWINGS OR AS REQUIRED. CONTRACTOR SHALL CAP SERVICES NEXT TO SERVICE MAINS IN CEILINGS, WALLS OR BELOW FLOOR. CONTRACTOR SHALL REROUTE AL ACTIVE PLUMBING SERVICES IN CHASES OR WALLS TO BE REMOVED, TO NEW CHASE AREAS OR NEW WALLS AS REQUIRED. 10. CONTRACTOR SHALL SUBMIT A COMPLETE LIST OF PLUMBING FIXTURES AND/OR EQUIPMENT THAT ARE TO BE REMOVED TO THE LOCAL OWNER'S REPRESENTATIVE. ALL ITEMS THAT THE LOCAL OWNER'S REPRESENTATIVE WISHES TO RETAIN SHALL BE TURNED OVER TO THE OWNER AND THE REMAINDER SHALL BE REMOVED FROM THE SITE AND LEGALLY DISPOSED. PLUMBING ABBREVIATIONS C.W COLD WATER PRY. PRESSURE REDUCING VALVE H.W. HOT WATER R.P.U. REDUCED PRESSURE BACKFLOW PREVENTER H.WR HOT WATER RECRC A.F.F. ABOVE FNSHED FLOOR V.TR VENT THRU ROOF AF.G. ABOVE FNIM GRADE W. WASTE (INTERIOR) A.P. ACCESS PANEL R.WL RAN WATER LEADER W.C.O. WALL CLEANOUT S.N. STORM WATER S.S. SANITARY SEWER LE. INVERT ELEVATION V.LV. VALVE N VERTICAL CA. CLEANOUT CA. COiOESATE OFCI OWNER R RIEM CONTRACTOR INSTALLED LE INVERT ELEVATION U. ROOF DRAM F.C.II. FAN COIL UNIT F.D. FLOOR DRAIN Nix. NOT N CONTRACT RREL FINISHED FLOOR ELEVATION E.W.C. ELECTRIC WATER COOLER PLUMBING LEGEND SnM OES"To SwIl 10"To --- COLD WATER BALL VALVE -- HOT WATER GIO'F) 1. CHECK VALVE ----- HOT WATER RECIRCL LATKIN P-1,ETC FO(TLRE NOENTIFICATKM _SSA SANITARY SEWER UWMM) CONNECTION TO COSTING -W- WASTE LINE -a CAP ON LINE --V-- VENT PIPE (ABOVE OR BELOW RKM) PPE TURNED UP --RWLP-- RAN WATER LEADER PPE TLFM DOWN STORM WATER OROERGROIIIO) SGPM .5GPM BALANCING VALCRCUIT SETTER W/OECK VALVE SET AT --SW- CLEANOUT (ABOVE CEI NW -D- DRIP TRMN ORAN LIE BCD-- CONDENSATE DRAW LINE PRESS IRE REDUCING VALVE LIOERGROW COLD WATER -PCD- PUMPED CONDENSATE 1. PLUMBING INSTALLATION OF ALL FIXTURES. EQUIPMENT, AND PIPING SHOWN ON THESE DRAWINGS SHALL BE INSTALLED IN ACCORDANCE WITH ALL APPLICABLE STATE, LOCAL AND HEALTH CODES REQUIREMENTS. 2. CONTRACTOR SHALL FIELD VERIFY EXISTING ELEVATIONS, SIZES AND LOCATIONS OF EXISTING PLUMBING PRIOR TO BIDDING. IF DISCREPANCIES ARE FOUND, THEY ARE TO NOTIFY ENGINEER. 3. ALL PLUMBING MB NG FIX20UORE S TO COMPLY WITH TABLE 604.3 OF THE FLORIDA BUIL4. CONTRACTOR SHALL COORDINATE EQUIPMENT CONNECTIONS & MOUNTING HEIGHTS WITH KITCHEN EQUIPMENT EQUIPMENT AND ARCHITECTURAL DRAWING AND SUPPLIER. INSTALL EOUIPMEW AND MAKE FINAL A SET OF THE EQUIPMENT DRAWINGS PRIOR TO BIDDING IN ORDER TO DETERMINE ALL REQUIRED CONNECTIONS. 5. PROVIDE 121XI2' ACCESS PANELS FOR ALL VALVES LOCATED ABOVE HARD CEILINGS. INSTALL VALVES SO AS TO BE WITHIN REACH OF ACCESS DOOR. 6. CONTRACTOR SHALL PROVIDE ROUGH -INS AND MAKE FINAL CONNECTIONS FOR EACH PIECE OF EQUIPMENT REQUIRING PLUMBING CONNECTION. INCLUDING TAILPIECES, TRAPS, LINE STRAINERS. STOP VALVES, GAUGES. VACUUM BREAKERS, REDUCING VALVES, SPECIAL FITTINGS, THERMOMETERS, GLOBE SOLENOID VALVES, INSULATION, AND ALL NECESSARY DEVICES FOR A COMPLETE AND OPERATIVE SYSTEM. COORDINATE EXACT REQUIRED PLUMBING ROUGH -INS WITH VENDOR SUPPLIER DRAWINGS. 7. THE CONTRACTOR SHALL INSTALL PLUMBING PIPING IN LOCATIONS INDICATED ON THE CONTRACT DOCUMENTS. THE ONLY DEVIATION FROM THIS WOULD BE IF ADDITIONAL OFFSETS ARE REQUIRED TO COORDINATE WITH OTHER TRADES. IF THE THE CONTRACTOR DESIRES TO CHANGE THE PLUMBING ROUTING FOR ANY OTHER REASON. HE SHALL COMPENSATE THE ENGINEER AT A RATE OF DPE x 2.T5 TO REVISE THE PLUMBING DRAWINGS. RISER DIAGRAMS AND FOR THE TIME INVOLVED IN REISSUING DRAWINGS TO THE AUTHORITY HAVING JURISDICTION. CONTRACTOR SHALL CONTACT ENGINEER FOR ESTIMATED TIME REQUIRED AND SCHEDULE FOR PERFORMING WORK. 8, EXISTING UTILITIES, WHICH ARE NOT SHOWN. THAT ARE DISCOVERED DURING DEMOLITION SHALL BE BROUGHT TO THE ATTENTION OF THE OWNER'S REPRESENTATIVE BY THE CONTRACTOR FOR PROPER CO- ORDINATION. CONTRACTOR SHALL REMOVE, REWORK AND/OR REROUTE THE EXISTING UTILITIES AS DIRECTED BY THE OWNER'S REPRESENTATIVE. 9. ALL MATERIALS, EQUIPMENT, AND APPARATUS SHALL BE NEW, EXCEPT THAT CALLED FOR AS BEING RE -USED OR FURNISHED BY OTHERS. 10. SEAL PENETRATIONS OF FIRE RATED WALLS AND FLOORS IN ACCORDANCE WITH U.L. FIRE RESISTANCE INDEX FOR THROUGH PENETRATION FIRE STOP SYSTEMS. COORDINATE REQUIREMENTS WITH ARCHITECTURAL PLANS AND SPECIFICATIONS. 11. CONTRACTOR SHALL FURNISH AND INSTALL SHOCK ABSORBERS ON FLUSH VALVE FIXTURES AND ALL LINES SERVING QUICK CLOSING VALVES AND AS INDICATED ON PLUMBING PLANS AND RECOMMENDED BY THE MANUFACTURER. 12. ANY WALL COVERS RV N ANYH CORRIDORBFLOORS IFEDISCREPANCIES RARE FOUND ON PLANS CONTRACTOR SHALL NOTIFY PLUMBING ENGINEER PRIOR TO INSTALLATION. 13• PIPING SHALL NOT BE RUN OVER ANY ELECTRICAL EQUIPMENT. PANELS AND PHONE PANELS. 14. SEE ARCHITECTURAL DRAWINGS FOR FIXTURE LOCATIONS AND MOUNTING HEIGHTS. 15. ALL EXPOSED PIPE AND FITTINGS IN FINISHED AREAS SHALL BE CHROME PLATED. 16. THE PLUMBING CONTRACTOR SHALL KEEP A SET OF MARKED UP DRAWINGS AS THE JOB PROGRESSES. NO MAJOR CHANGE SHALL BE MADE TO PLUMBING DESIGN EENNGIN ERING UNLESS IT HAS BEEN COORDINATED, DRAWN AND SUBMITTED FOR APPROVAO. 17. CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGES TO EXISTING PIPING AND FIXTURES DUE TO NEW CONSTRUCTION AND SHALL RESTORE EXISTING WORK DISTURBED TO IT'S ORIGINAL CONDITION AT NO COST TO THE OWNER. 18. CONTRACTOR SHALL COORDINATE WITH ALL DISCIPLINES INVOLVED SO AS TO AVOID ANY PIPE ROUTING PROBLEMS. 19. PROVIDE OFFSETS AND FITTINGS AS REQUIRED. 20. ALL INTAKES, SHALL BE WIINDOWS5'-0' AWAY FROM 21. WHEN BEAM SLEEVE PENETRATIONS ARE NECESSARY, NOTIFY AND COORDINATE PENETRATIONS WITH ALL TRADES. THE ARCHITECT AND STRUCTURAL ENGINEER PRIOR TO PENETRATING ANY BEAMS. 22. COORDINATE INSTALLATION OF PLUMBING SYSTEMS WITH ALL CASEWORK. CONTRACTOR SHALL OBTAIN ARCHITECTURAL DRAWINGS AND REVIEW PRIOR TO INSTALLATION. 23. FITTINGS WHICH WILLDIRECTION CAUSE EXCESSIVE REDUCTIONHN THE VELOCITYD OF WITH OR CREATE ANY OTHER ADVERSE EFFECT UNLESS PHYSICALLY IMPOSSIBLE GEs USE OF SANITARY TEE IN A HORIZONTAL CONNECTION. USE OF A DOUBLE PLUMBING FIXTURE SCHEDULE FIXTURE FITTING ____7MANUFACTURER FLOOR MOUNTED C.W H.W. WASTE REMARKS MODEL TYPE SIZE MANUFACTURER TYPE SUPPLY TRAP FAUCET SYMBOL CARRIER P-5A KOHLER (HC) HIGHLINE K-3544 FLUSH TANK FLOOR MOUNTED ELONGATED McGUIRE NA H-2165 INTEGRAL NA NA I /� -- 4 K-4670C WHITE. SEAT WATER CLOSET 1.5 GALLON VITREOUS CHINA BOWL KOHLER (HC) KINGSTON WALL HUNG CONCEALED ARM 5' BACKSPLASH 21 X18 McGUIRE 155WC OFFSET H-2165 *8872 11/4 P-TRAP OFFSET FOR WHEEL CHICAGO FAUCET •895-317FC ZURN I/� I/� lI/� MOUNT 34' A.F.F. TO RIM. PROVIDE TRUEBRO LAV P-13 LAVATORY K-2005 VITREOUS CHINA 4' FAUCET CTR STRAINER CHAIR USE WRISTBLADE HANDLE Z-1231 SHIELD *2018. JUST -(STAFF) *SL-ADA- SINGLE COMP. (S.S.) 18 GAUGE 14' X 16' X 61/1 McGUIRE # PROWRAP PW1152 WC H-2165 PROWRAP #PW2150 11/ P-TRAP OFFSET CHICAGO FAUCET NA 1/� 1/� 11/1 NA P-20A S.S. SINK 2019-A-GR SELF -RIMMING OFFSET STRAINER FOR WHEEL CHAIR USE *786-GN2FCCP NOTE: 1. INSTALLATION OF FIXTURES SHALL BE FULLY COORDINATED WITH GRAB BARS. 2. CONTRACTOR SHALL PROVIDE ALL REQUIRED MATERIAL FOR A COMPLETE INSTALLATION OF THE PLUMBING FIXTURES INCLUDING ANY GROUT AS REQUIRED AT WALL HUNG FIXTURES. COORDINATE WITH ARCHITECT FOR SPECIFIC GROUT REQUIREMENTS. 3. PROVIDE SYMMONS THERMOSTATIC MIXING VALVE *5-210-CK 1/2 GPM MIN, 2 GPM MAX ON FAUCETS. SET AT 110' F. SEE DETAILS. INSTALL PER MANUFACTURERS WRITTEN INSTRUCTIONS. 24. THIS CONTRACTOR SHALL BASE HIS PROPOSAL UPON T SCHEDULED OR SPECIFIEDr USING THE MANUFACTURERS AS CALLED FOR IN THE JPECIFICATIONS AND SCHEDULE THE DRAWINGS. IF MORE THAN ONE MANUFACTURER OF EQUIPMENT IS SPECIFIED ANY ONE OF THE MANUFACTURERS OF EQUIPMENT MAY BE USED IN THIS CONTRACTOR'S PROPOSAL. IF THIS CONTRACTOR WISHES TO USE EQUIPMENT NOT SPECIFIED HE MUST AT THE TIME OF BIDDING, SUBMIT SEPARATELY ON LETTERHEAD STATIONARY dF THE BIDDER THE EQUIPMENT HE WOULD SUBSTITUTE AND THE COST TO BE ADDED bR TO BE DEDUCTED FROM HIS PROPOSAL. 25. THE CONTRACTOR IS EXPECTED TO ORDER ALL MATERIALS IN SUFFICIENT TIME TO AVOID DELAYING THE COMPLETION OF THE PROJECT. DELAY IN DELIVERIES WILL NOT BE CONSIDERED A JUSTIFIABLE REASON FOR SUBMISSION OF SUBSTITUTE MATERIALS. 26. WARRANTY/GUARANTEE A.THE CONTRACTOR SHALL WARRANTY/GUARANTEE AND MAINTAIN THE STABILITY OF WORK AND MATERIALS AND KEEP SAME IN PERFECT REPAIR AND CONDITION FOR THE PERIOD OF ONE YEAR. B. DEFECTS OF ANY KIND DUE TO FAULTY WORK OR MATERIALS. APPEARING DURING THE ABOVE MENTIONED PERIOD, MUST BE IMMEDIATELY REPAIRED BY THE CONTRACTOR AT HIS OWN EXPENSE TO THE ENTIRE SATISFACTION OF THE OWNER AND ENGINEER. SUCH RECONSTRUCTION AND REPAIRS SHALL INCLUDE DAMAGE TO THE FINISH OR FURNISHING OF THE BUILDING RESULTING FROM THE ORIGINAL DEFECT OR REPAIR THERETO. 2T. 2. THE CONTRACTOR SHALL INCLUDE IN BID PRICE ALL PREMIUM TIME CHARGES FOR LABOR AND EQUIPMENT REQUIRED FOR ALL NIGHT AND WEEKEND OVERTIME WORK, AS NECESSARY, TO COMPLETE THE SCOPE OF THE CONTRACT. 28. ALL CONDENSATE PIPING SHALL BE INSULATED THROUGHOUT ENTIRE SYSTEM. 29. PROVIDE A MINIMUM OF 6 INCHES BETWEEN ALL PIPING AND FIRE RATED AND SMOKE TIGHT PARTITIONS FOR REQUIRED INSPECTIONS. ANY PIPING WITHIN THIS 6 INCHES SPACE SHALL BE REQUIRED TO BE MOVED AND REROUTED. ANY COST IMPACT TO OTHER TRADES WILL BE THE RESPONSIBILITY OF THE CONTRACTOR. 30. THE MAXIMUM VERTICAL DISTANCE FROM THE FIXTURE OUTLET TO THE TRAP WEIR SHALL NOT EXCEED 24-INCHES AND THE HORIZONTAL DISTANCE SHALL NOT EXCEED 30-INCHES MEASURED FROM THE CENTER LINE OF FIXTURE OUTLET TO THE CENTERLINE OF THE INLET OF THE TRAP AS PER SECTION 1002 OF THE FLORIDA PLUMBING CODE 2007. 31. PROVIDE THE REQUIRED CLEARANCES AND SPACE FOR ALL PLUMBING FIXTURES. PLUMBING CONTRACTOR SHALL VERIFY AND COORDINATE PRIOR TO THE START OF CONSTRUCTION. 32. ALL FLUSH VALVES, FIXTURE STOPS, VALVES, ETC., ALL PIPING SHALL BE RIGIDLY SECURED (NO MOVEMENT WHEN OPERATED). INSTALL PERMANENT STAMPED BRASS VALVE TAG ON EACH VALVE. COORDINATE WITH OWNER'S IDENTIFICATION SYSTEM. 33. INSULATION, FITTINGS COVERS AND ALL FINISHES AND MATERIALS SHALL HAVE A MAXIMUM FLAME SPREAD RATING OF 25 AND A MAXIMUM SMOKE DEVELOPED RATING OF 50. 34. DRAWINGS ARE DIAGRAMMATIC. DO NOT SCALE FROM DRAWINGS. BUT FIT WORK TO ACTUAL CONDITION AND SPACE REQUIREMENTS. 35. ALL WORK SHALL BE PERFORMED BY A LICENSED CONTRACTOR IN A FIRST CLASS WORKMANLIKE MANNER. THE COMPLETE SYSTEM SHALL BE FULLY AND PROPERLY OPERATIVE, AND IN COMPLIANCE WITH APPLICABLE CODES AND GOVERNING AUTHORITIES AND SUBJECT TO ACCEPTANCE BY OWNER/ENGINEER. 36. CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS, FEES, INSPECTIONS AND TESTS. 37. ALL REQUIRED INSURANCES SHALL BE PROVIDED AND MAINTAINED BY THE CONTRACTOR FOR THE PROTECTION AGAINST PUBLIC LIABILITY AND PROPERTY DAMAGE, AND OTHER INSURANCES REQUIRED BY THE OWNER, FOR THE DURATION OF THE WORK. 38. GENERAL NOTEi TEMPERATURE OF HOT WATER TO PUBLIC REST ROOMS SHALL NOT EXCEED I10' F. PER FLORIDA ENERGY CODE 412.1.ABCD.2.3.2. CONTRACTOR SHALL VERIFY TEMPERATURE OF HOT WATER SYSTEM WITH OWNER. INSTALL TEMPERING VALVES AS REQUIRED, FOR A MAXIMUM TEMPERATURE OF 110' F SUBJECT TO REVIEW BY ENGINEER. 39. CONTRACTOR SHALL PROVIDE POTABLE WATER TEST FOR DOMESTIC COLD AND HOT WATER SYSTEMS BEFORE AND AFTER MODIFICATIONS ARE COMPLETE FOR CONTAMINANTS. 40. ALL NEW VALVES INSTALLED IN DOMESTIC WATER SYSTEMS SHALL BE NSF-61 CERTIFIED. 41. CONTRACTOR SHALL SAW CUT CONCRETE FLOOR SLAB TO INSTALL NEW BELOW SLAB PIPING AND SHALL PATCH THE SLAB TO MATCH THE EXISTING CONCRETE SLAB. WATER HEATER SCHEDULE SYSTEM TYPE MANUFACTURER MODEL No. KW TOT. STORAGE FLOW ELECKW REMARKS CAPACITY RECOVERY WATER ELECTRIC LOCHINVAR LSK030KK 4.5 4.5 30 31 GPH 2O8V ENERGY SAVER, GLASS LINED HEATER WHI ENERGY SHORT MODEL GALLON 600 F RISE 3 PH. MAGNESIUM TANK SAVER, SAVER INSTALL EQUIPMENT IN ACCORDANCE WITH MANUFACTURER'S WRITTEN INSTRUCTIONS. U.L. LISTED. PROVIDE HEATER WITH THE FOLLOWING OPTIONS: 1. 3 YEAR WARRANTY 2. TEMPERATURE AND PRESSURE GAUGE 3. NSF CONSTRUCTION DRAWING INDEX SHEET NUMBER SHEET TITLE PO.1 PLUMBING SPECS, LEGENDS, SCHEDULES, AND DRAWING INDEX P1.0 UNDERGROUND PLAN - DEMOLITION - PLUMBING P1.1 FIRST FLOOR PLAN - DEMOLITION - PLUMBING P2.0 UNDERGROUND PLAN - NEW CONSTRUCTION - PLUMBING P2.1 FIRST FLOOR PLAN - NEW CONSTRUCTION - PLUMBING P4.1 PLUMBING RISER DIAGRAMS P5.1 PLUMBING TYPICAL DETAILS E:1Mo 6 E. ftb dw TE OF : U 4. �A►A1.tE���� SRSmith Seckman Reid, Inc. 600 West Hillsboro, Suite 300 Deerfield Beach, FL 33441 (954)421-1260 FAX: (954) 421-1466 www.ssr-inc.com Firm Certification - EB-0000867 Dennis Davie PE - 58588 John E. Moulder PE - 88200 SSR JOB # 1137001.0 -v; N k2 o� �s . a A Al. 2 .s x a v .. y � o a U) 0 N Cz 0 I _ _0 C� _O CD ( -- U m U a� O cl w U U Q � U) C 0 G Cn EO ^:3 CV Project No. 11006.00 PO . 1 02011 BRIPE Architects, Inc. 1 ? :,• � � :: • � ifs T � . - � � t .:. ! ..'i ,'�,�$Q ��++ � �1i � t a ,. ry/ « ! 4 Ell . a Ln 0 0 N 0 4 31 L3" 311 3 UP TO - 3" FCO W 3'1 3" W 411 3" ' 3 3�� ................ 4" 3 .... ... .... 4114"4 W ...................................................................................................................................................................... UNDERGROUND PLAN - DEMOLITION - PLUMBING 0' 2' 4' 8' 16' 24' GENERAL NOTES: 1. CONTRACTOR SHALL PATCH WALLS AND CEILINGS TO MATCH EXISTING FINISHES FOR DEMOLITION AND INSTALLATION OF PIPING, ETC. UNLESS NOTED OTHERWISE ON ARCH. DRAWINGS. 2. THE CONTRACTOR SHALL HAVE TO PERFORM WORK WITHIN ACTIVE PATIENT CARE AREAS. CONTRACTOR SHALL: A. COORDINATE SHUTDOWN OF EXISTING SYSTEMS WELL IN ADVANCE WITH OWNER. B. PERFORM WORK AT SUCH TIMES AND UNDER SUCH CONDITIONS AS PRESCRIBED BY OWNER. C. SEQUENCE DEMOLITION AND NEW CONSTRUCTION TO MINIMIZE NUMBER & DURATION OF SHUTDOWNS REQUIRED. 3. CONTRACTOR SHALL COORDINATE WORK WITH EXISTING CONDITIONS (STRUCTURE, DUCTWORK, PIPING, CONDUIT, ETC.). PROVIDE OFFSETS AS REQUIRED TO INSTALL NEW WORK. 4. CONTRACTOR SHALL SAW CUT CONCRETE GROUND FLOOR SLAB AS REQUIRED TO ACCOMMODATE DEMOLITION AND NEW WORK SHOWN. PATCH WITH SIMILAR MATERIALS TO MATCH EXISTING. SEE ARCH. DRAWINGS. 5. CONTRACTOR SHALL VERIFY SLOPE, INVERT AND CONDITION OF EXISTING UNDERGROUND SANITARY PIPE PRIOR COMMENCING ANY NEW WORK PIPE INSTALLATION BELOW SLAB, AND PRIOR TO SAW CUTTING SLAB. SCOPE PIPE WITH CAMERA TO DETERMINE CONDITION OF PIPE, IF DETERMINATION CAN NOT BE MADE. SAW CUT SLAB FIRST AT AREA OF NEW TO EXISTING CONNECTION TO DETERMINE EXISTING PIPE CONDITION. 6. CONTRACTOR TO REMOVE EXISTING STACKS AND RISERS LOCATED IN EXISTING WALLS TO BE DEMOLISHED AND PROVIDE NEW OFFSETS AT CEILING ABOVE AND BELOW SLAB TO NEW STACK OR RISER LOCATION COORDINATED WITH FLOOR PLAN LAYOUT AND EXISTING CONDITIONS. 7. CONTRACTOR SHALL VERIFY WITH BUILDING MAINTENANCE AREAS AFFECTED BY SHUTDOWNS FOR SANITARY REQUIRED TO PERFORM DEMOLITION AND NEW CONSTRUCTION. LEGEND SYMBOL DESCRIPTION rDEMOLITION EXISTING TO REMAIN EXISTING TO BE REMOVED �—� REMOVE EXISTING TO THIS POINT �`•�r1 E. MOV i 0 • o. E OF : 44., AL Smith Seckman Reid, Inc. 600 West Hillsboro, Suite 300 Deerfield Beach, FL 33441 (954) 421-1260 FAX: (954) 421-1466 www.ssr-inc.com Firm Certification - EB-0000857 Dennis Davis PE - 58588 John E. Moulder PE - 33200 SSR JOB # 1137001.0 v� p "=t' :2 a -;' 0 V Y y ti V � O O Q A V i L� N 4—j .Q U) O (� -L E O _D 1-1 a I O O E In C _U O C� a_U_ 7 C 0 70 � O CV T Project No.11006,00 P1.0 02011 BHIPHArchitects, Inc. R - �.:..-.',... �-�- _. a _4E .: �1. � �.... :� _ .. 4;�.. n.. � i' "-#wAr �:,�, i -,,. fi ,. r ��� ..1%: -� ��5.�' I�� ,.� w J_ Z M W a L2 I- Ln 0 J 0 N 0 h O 1 1/4 " 2" drl W.H.0 GENERAL NOTES: 1/2 FIRST FLOOR PLAN - DEMOLITION - PLUMBING /N 1. CONTRACTOR SHALL PATCH WALLS AND CEILINGS TO MATCH EXISTING FINISHES FOR KEYED NOTES: DEMOLITION AND INSTALLATION OF PIPING, ETC. UNLESS NOTED OTHERWISE ON ARCH. DRAWINGS. 2. THE CONTRACTOR SHALL HAVE TO PERFORM WORK WITHIN ACTIVE PATIENT CARE AREAS. CONTRACTOR SHALL: A. COORDINATE SHUTDOWN OF EXISTING SYSTEMS WELL IN ADVANCE WITH OWNER. B. PERFORM WORK AT SUCH TIMES AND UNDER SUCH CONDITIONS AS PRESCRIBED BY OWNER. C. SEQUENCE DEMOLITION AND NEW CONSTRUCTION TO MINIMIZE NUMBER & DURATION OF SHUTDOWNS REQUIRED. 3. CONTRACTOR SHALL COORDINATE WORK WITH EXISTING CONDITIONS (STRUCTURE, DUCTWORK, PIPING, CONDUIT, ETC.). PROVIDE OFFSETS AS REQUIRED TO INSTALL NEW WORK. 4. WORK MAY NOT BE LIMITED TO SCOPE OF WORK OR PHASING AREAS INDICATED, BUT ALSO MAY INCLUDE WORK OUTSIDE OF THE SCOPE OF WORK OR PHASING AREAS AS INDICATED BY CONTRACT DOCUMENTS. 5. CONTRACTOR SHALL LABEL EXISTING PIPING SHOWN TO REMAIN ON DRAWING, MADE ACCESSIBLE BY CONSTRUCTION WORK, PER SPECIFICATIONS. 6. ALL WASTE, AND AND CONDENSATTEP PIING CONDENSATE2 /1 & PIPING LARGER 8TO LESS BE SLOPED SLOPED I/j/FT 1/4/FT. ALL WASTE, 7. CONTRACTOR SHALL FIELD VERIFY WITH HOSPITAL LOCATION OF EXISTING SERVICE VALVES FOR SHUTDOWN OF CW AND HW. COORDINATE TIMING, DURATION AND AREA AFFECTED BY SHUTDOWN WITH HOSPITAL. S. CONTRACTOR TO REMOVE EXISTING STACKS AND RISERS LOCATED IN EXISTING WALLS TO BE DEMOLISHED AND PROVIDE NEW OFFSETS AT CEILING ABOVE AND BELOW SLAB TO NEW STACK OR RISER LOCATION COORDINATED WITH FLOOR PLAN LAYOUT AND EXISTING CONDITIONS. 9. CONTRACTOR SHALL VERIFY WITH BUILDING MAINTENANCE AREAS AFFECTED BY SHUTDOWNS FOR CW, HW AND SANITARY REQUIRED TO PERFORM DEMOLITION AND NEW CONSTRUCTION. OREMOVE EXISING PLUMING FIXTURE AND INSTALL NW FIXTURE. CNNECT NEW F WASTE, VENT,AND NEW BCW AND HW PIPING LOCATEDE IN WALLS OR OBELOW FLOOR.IXTURE TO EXISTING EXTEND/ADJUST EXISTING WASTE, VENT, CW & HW PIPING WITHIN WALL AS REQUIRED. COORDINATE TIMING OF WORK WITH NEW FINISH INSTALLATION. PROVIDE ADD ALTERNATE TO REPLACE EXISTING SHUTOFF VALVES ON BRANCH PIPING SERVING AREA. VERIFY PROPER VALVE OPERATION AND REPLACE AS REQUIRED. O2 REMOVE EXISTING FIXTURE AND BRANCH CW, HW, WASTE AND VENT PIPING BACK TO MAINS OR TO LIMITS SHOWN. CAP AS REQUIRED. OREMOVE EXISTING FLOOR DRAIN AND TRAP PRIMER, ALONG WITH ALL ASSOCIATED WASTE, VENT, AND CW LINE BACK TO MAINS AND CAP AS REQUIRED. O REMOVE EXISTING CW, HW, WASTE AND VENT PIPING WITHIN WALL. DEMOLITION LEGEND L DESCRIPTION EXISTING TO REMAIN r EXISTING TO BE REMOVED REMOVE EXISTING TO THIS POINT Tfi E OF 0: ;oNL. A0E;,�`• Smith Seckman Reid, Inc. 600 West Hillsboro, Suite 300 Deerfield Beach, FL 33441 (954) 421-1260 FAX: (954) 421-1466 www.ssr-inc.com Firm Certification - EB-0000867 Dennis Davie PE - U588 John E. Moulder PE - 33200 SSR JOB # 1137001.0 w z az it� o �g LO -s x �Qj u .3 u ti y O O � e A V! I- N co 4-j Cn O CKI _-0 CY) _O EI CD 1 O m O U E CV `F- 0 0 1 (� U_ _(Z a- C i G O W O -�e LL (CS a-, 0 U) �= CV LL r Project No. 11006.00 p 1 1 02011 B K Architects, Inc. F I _ I I 1 I 1' I in 11 r1L! ? 111 IF 1 _ 1111 !1 1-.! 1 1 'll I I I ' 1 11 1 1 II .: -13 1' 11 I. :'T . I I I c 0 N 1= � a a i L, o ' o Ln O r_ M 0 N M E N o "1 Q) o Lin .. W O J J H <L � Z IJ C,r) Lil Q O UP TO 3" FCO 3 311 � 3n � 3�� .... .... .. ..... .................__.. _. .......... GENERAL NOTES: I. CONTRACTOR SHALL PATCH WALLS AND CEILINGS TO MATCH EXISTING FINISHES FOR DEMOLITION AND INSTALLATION OF PIPING, ETC. UNLESS NOTED OTHERWISE ON ARCH. DRAWINGS. 2. THE CONTRACTOR SHALL HAVE TO PERFORM WORK WITHIN ACTIVE PATIENT CARE AREAS. CONTRACTOR SHALL: A. COORDINATE SHUTDOWN OF EXISTING SYSTEMS WELL IN ADVANCE WITH OWNER. B. PERFORM WORK AT SUCH TIMES AND UNDER SUCH CONDITIONS AS PRESCRIBED BY OWNER. C. SEQUENCE DEMOLITION AND NEW CONSTRUCTION TO MINIMIZE NUMBER & DURATION OF SHUTDOWNS REQUIRED. 3. CONTRACTOR SHALL COORDINATE WORK WITH EXISTING CONDITIONS (STRUCTURE, DUCTWORK, PIPING, CONDUIT, ETC.). PROVIDE OFFSETS AS REQUIRED TO INSTALL NEW WORK. 4. WORK MAY NOT BE LIMITED TO SCOPE OF WORK OR PHASING AREAS INDICATED, BUT ALSO MAY INCLUDE WORK OUTSIDE OF THE SCOPE OF WORK OR PHASING AREAS AS INDICATED BY CONTRACT DOCUMENTS. 5. ALL WASTE, AND CONDENSATE PIPING 2' & LESS TO BE SLOPED o 1/4/FT. ALL WASTE, AND CONDENSATE PIPING 21/2 & LARGER TO BE SLOPED C '/d/FT. 6. CONTRACTOR SHALL SAW CUT CONCRETE GROUND FLOOR SLAB AS REQUIRED TO ACCOMMODATE DEMOLITION AND NEW WORK SHOWN. PATCH WITH SIMILAR MATERIALS TO MATCH EXISTING. SEE ARCH. DRAWINGS. 7. CONTRACTOR SHALL VERIFY SLOPE, INVERT AND CONDITION OF EXISTING UNDERGROUND SANITARY PIPE PRIOR COMMENCING ANY NEW WORK PIPE INSTALLATION BELOW SLAB, AND PRIOR TO SAW CUTTING SLAB. SCOPE PIPE WITH CAMERA TO DETERMINE CONDITION OF PIPE, IF DETERMINATION CAN NOT BE MADE. SAW CUT SLAB FIRST AT AREA OF NEW TO EXISTING CONNECTION TO DETERMINE EXISTING PIPE CONDITION. 8. CONTRACTOR TO REMOVE EXISTING STACKS AND RISERS LOCATED IN EXISTING WALLS TO BE DEMOLISHED AND PROVIDE NEW OFFSETS AT CEILING ABOVE AND BELOW SLAB TO NEW STACK OR RISER LOCATION COORDINATED WITH FLOOR PLAN LAYOUT AND EXISTING CONDITIONS. 9. CONTRACTOR SHALL VERIFY WITH BUILDING MAINTENANCE AREAS AFFECTED BY SHUTDOWNS FOR SANITARY REQUIRED TO PERFORM DEMOLITION AND NEW CONSTRUCTION. W W W0 ....... . ............. _..._....... ............ .......... --4"ECO UNDERGROUND PLAN - NEW CONSTRUCTION - PLUMBING N1 77 KEYED NOTES: O 3" WASTE TO BE CONNECTED TO EXISTING 3' SANITARY BELOW SLAB. GENERAL NOTES: 1. ALL SANITARY PIPING 2" & LESS TO BE SLOPE @ 1/'/FT. ALL SANITARY PIPING 217 & LAGER TO BE SLOPED @21/4/FT. 2. PROVIDE CLEANOUTS AT BASE OF ALL STACKS. NEW CONSTRUCTION LEGEND SYMBOL DESCRIPTION - EXISTING TO REMAIN NEW CONSTRUCTION CONNECT TO EXIST. AT THIS POINT fc MO���� moo. •. ,. OF AL p�1tE`\�� Smith Seckman Reid, Inc. 600 West Hillsboro, Suite 300 Deerfield Beach, FL 33441 (954)421-1260 FAX: (954) 421-1466 www.ssr-inc.com Firm Certification - EB-0000857 Dennis Davis PE - 58588 John E. Moulder PE - 33200 SSR JOB # 1137001.0 �Y G C.� -- U A � 6 C ~ s'�wN y � ICJ AL O U 0 n �i n o` Cn I Q_ N _�_ Cn O _ I C _U O LL U � Cn O U 5 m Q� Q� z U 0 C� C� U_ 7C) 70 O IL CIO (1) 7C) 0 CV T Project No. 11006.00 P2. 0 ©2011 BNIPKArchitects, Inc. "NVIA 11 h I � ON Ala c N E a 0 0 0 0 N rn E a a) L 2 U LL C a Ln In 0 ;W O N 0 ens mm T. P. J CD A/C 3/411 A/C 3/41 D u I I n (3 V �2 V L 1,'�D P-20A P-20, 2 ....... - _ __ 771. > 1" 3/a' /Z -- i 3nVTR', p_1,-3 OVERFLOW t RELIEF I I II/a' I 1 I/q — 3 k, FIRST FLOOR PLAN - NEW CONSTRUCTION - PLUMBING GENERAL NOTES: 0' T 4' g' 10' 24' 1. CONTRACTOR SHALL PATCH WALLS AND CEILINGS TO MATCH EXISTING FINISHES FOR DEMOLITION AND INSTALLATION OF PIPING, ETC. UNLESS NOTED OTHERWISE ON ARCH. DRAWINGS. KEYED NOTES: 2. THE CONTRACTOR SHALL HAVE TO PERFORM WORK WITHIN ACTIVE PATIENT CARE AREAS. CONTRACTOR SHALL: Oi INSTALL NEW FIXTURE. CONNECT NEW FIXTURE TO EXISTING WASTE, VENT, AND NEW CW AND HW PIPING LOCATED IN WALLS OR BELOW FLOOR. PROVIDE NEW SHOCK ARRESTORS ON CW AND HW BRANCH PIPING A. COORDINATE SHUTDOWN OF EXISTING SYSTEMS WELL IN ADVANCE WITH OWNER. TO FIXTURES. EXTEND/ADJUST EXISTING WASTE, VENT, CW & HW PIPING WITHIN WALL AS REQUIRED. COORDINATE TIMING OF WORK WITH NEW FINISH INSTALLATION. PROVIDE ADD ALTERNATE TO REPLACE EXISTING SHUTOFF VALVES ON BRANCH PIPING SERVING AREA. VERIFY PROPER VALVE OPERATION AND REPLACE AS REQUIRED. B. PERFORM WORK AT SUCH TIMES AND UNDER SUCH CONDITIONS AS PRESCRIBED BY OWNER. C. SEQUENCE DEMOLITION AND NEW CONSTRUCTION TO MINIMIZE NUMBER & DURATION OF O NEW CONDENSATE DRYWELL. COORDINATE EXACT LOCATION IN FIELD WITH EXISTING LANDSCAPING. SEE DETAIL. SHUTDOWNS REQUIRED. 3. CONTRACTOR SHALL COORDINATE WORK WITH EXISTING CONDITIONS (STRUCTURE, DUCTWORK, O CAP VENT, CW, AND HW ABOVE CEILING. PIPING, CONDUIT, ETC.). PROVIDE OFFSETS AS REQUIRED TO INSTALL NEW WORK. 4. WORK MAY NOT BE LIMITED TO SCOPE OF WORK OR PHASING AREAS INDICATED, BUT ALSO MAY O ELECTRIC WATER HEATER MOUNTED ABOVE CEILING ON A PLATFORM. T&P LINE TO TERMINATE ON DRAIN PAN. ROUTE 1 EMERGENCY DRAIN PAN TO EQUIPMENT ROOM AND TERMINATE OVER FLOOR DRAIN WITH AN AIR GAP. SEE DETAIL. INCLUDE WORK OUTSIDE OF THE SCOPE OF WORK OR PHASING AREAS AS INDICATED BY CONTRACT DOCUMENTS. O CONNECT NEW I1/2 CW LINE TO EXISTING 2' CW. 5. CONTRACTOR SHALL LABEL EXISTING PIPING SHOWN TO REMAIN ON DRAWING, MADE ACCESSIBLE O PROVIDE WATTS LEAD FREE #LF-009-QT BACKFLOW PREVENTER AND AN ADDITIONAL VALVE ON EACH SIDE FOR SERVICE. BY CONSTRUCTION WORK, PER SPECIFICATIONS. 6, ALL WASTE, AND CONDENSATE PIPING 2" & LESS TO BE SLOPED C 1/a'/FT. ALL WASTE, AND CONDENSATE PIPING 21/2 & LARGER TO BE SLOPED 9 I/d/FT. 7. CONTRACTOR SHALL FIELD VERIFY WITH HOSPITAL LOCATION OF EXISTING SERVICE VALVES FOR SHUTDOWN OF CW AND HW. COORDINATE TIMING, DURATION AND AREA AFFECTED BY SHUTDOWN WITH HOSPITAL. 8. CONTRACTOR TO REMOVE EXISTING STACKS AND RISERS LOCATED IN EXISTING WALLS TO BE DEMOLISHED AND PROVIDE NEW OFFSETS AT CEILING ABOVE AND BELOW SLAB TO NEW STACK OR RISER LOCATION COORDINATED WITH FLOOR PLAN LAYOUT AND EXISTING CONDITIONS. 9. CONTRACTOR SHALL VERIFY WITH BUILDING MAINTENANCE AREAS AFFECTED BY SHUTDOWNS FOR CW, HW AND SANITARY REQUIRED TO PERFORM DEMOLITION AND NEW CONSTRUCTION. NEW CONSTRUCTION LEGEND SYMBOL DESCRIPTION EXISTING TO REMAIN NEW CONSTRUCTION -� - - CONNECT TO EXIST. AT THIS POINT >o•''\GEN 3 �iE (OF ' W' ,�, '.4pR1VP:�•� s • - ca �� %O N Ai,i Smith Seckman Reid, Inc- 600 West Hillsboro, Suite 300 Deerfield Beach, FL 33441 (954) 421-1260 FAX: (954) 421-1466 www.ssr-inc.com Firm Certification - EB-0000857 Dennis Davie PE - 58588 John E. Moulder PE - 33200 SSR JOB # 1137001.0 Project No. 11006,00 P2. 11 ©2011 BHIPKArchitecis, Inc. GENERAL NOTES: c E Q a Q, L o � o Ln rn =96, W O n w , Z Co cn w O 1. ALL SANITARY PIPING 2' & LESS TO BE SLOPTJ 0 1 /FT. ALL SANITARY PIPING 2I& LARGER TO BE SLOPED Q /d/FT. 2. PROVIDE CLEANOUTS AT BASE OF ALL STACKS. 0 2'(TYP) 2 3"VTR 2' i P-20A > CO ' P-13 2 ,0 1 �/� P-20A 3' 2" W 2" CO P-20A w PARTIAL FIRST FLOOR - SANITARY RISER NO SCALE CO ELECTRIC WATER HEATER PLATFORM MOUNTED ABOVE CEILING. SEE DETAIL. OVERINFLOOR DRATE AIN ��IN SHUTOFF VALVE AT 7'-6" A.F.F. PROVIDE WATTS LEAD FREE #LF-009-OT BFP PARTIAL FIRST FLOOR - DOMESTC WATER RISER NO SCALE '/1 P-5A PCN/ FIG. NO. P.D.J. SYMBOL FIXTURE UNIT RATING SIZE SIZE SIZE 5005 A 1-11 1 4 3 5010 B 12-32 1 5 3 5020 C 33-60 1 6 3 5030 D 61-113 1 1 7 3 5040 E 114-154 1 8 3 5060 F 155-330 1 9 3 NEW CONSTRUCTION LEGEND SYMBOL DESCRIPTION EXISTING TO REMAIN NEW CONSTRUCTION -F� CONNECT TO EXIST. AT THIS POINT MOdo • �• i �(OF ;"-Z �NAL,E����` Smith Seckman Reid, Inc. 600 West Hillsboro, Suite 300 Deerfield Beach, FL 33441 (954) 421-1260 FAX: (954) 421-1466 www.ssr-inc.com Firm Certification - EB-0000867 Dennis Davis PE - 68688 John E. Moulder PE - 33200 SSR JOB # 1137001.0 1 0/1 WN 0990 Q o� t2 o � o .� a x v Q. q 9 4 Cn L_ Q. N cz 4-1 Co 0 _L— _O L.L 1 0) m U 0 C� �— U_ Cn Co E 0 ^D N CL T-- ProjectNo. 11006,00 P4, 1 02011 BHIPS Architects, Inc. F— 4- Li 2 a 0 0 0 IN 0 cv 0 Ln J n iL O PLAIN END OUTLET 2" VENT I LAVATORY GRADE I FAUCET I \ �j 5 % - MAXLINE VALVE w � I HOT 4 VALVE VALVE 20" X 24" LONG I Ln WATER TANK, HEATER, TEMPERED ETC. HOT SUPPLY PEA GRAVEL MAIN HOT SUPPLY 04 I I COLD SUPPLY \ I SINK OR LAVATORY RIM NOTES: / \ 1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS 2. SET TEMPERATURE TO 1100 MAXIMUM PER FBC. NOTE: HANDLES TO BE POSITIONED AT AN 180' ANGLE IN THE CLOSED POSITION. DRY WELL DETAIL TYPICAL GOOSENECK INSTALLATION MIXING VALVE PIPING AT FAUCETS WOOD TR SS STRUCTURAL SUPPORT SYSTEM. HANGER ROD. PROVIDE A SECTION OF HIGH COMPRESSION STRENGTH .'�: o .:a: 'o, °:. .. c::'a c.e ..:a:.; ..:° .. ..:•o:•-a. :.6:.. o ..: INSULATION AT EACH HANGER POINT. INSULATION MAY BE PHILLIPS CONCRETE FASTENER HALF ROUND OR FULL ROUND AND EXTEND 2"BEYOND GALVANIZED SHIELD EACH WAY. I.T.T. GRINNELL (RED HEAD) THERMAL EXPANSION TANK PROVIDE 3/8" DIAMETER WATTS#DET-12-M1,ANS1/NSFG THREADED ROD WITH 4.5GAL,1.8GAL ACCEPTANCE WASHERS AND DOUBLE ALL THREAD- SUPPORT FROM STRUCTURE NUTS AT EACH END. i eC HANGER ROD HEAT TRAPS ROUTE ROD FROM CHANNEL BELOW WATER GALVANIZED (OMIT IF HEAT TRAP IS AN HEATER UP TO FASTENERS SHIELD INTEGRAL PART OF HEATER) ABOVE. (TYPICAL OF 4). HOT WATER TO FIXTURES COLD WATER SUPPLY AS SHOWN ON PLANS. TO WATER HEATERU) i PIPE HANGER RING THERMOMETER - T VACUUM RELIEF VALVE i 4- I.T.T. GRINNELL FIG.69 WATTS #36A OR APPROVED EQUAL PROVIDE FULL PORT BALL UNINSULATED COPPER LINES SHUT-OFF VALVES. PROVIDE A 210A PIPE CLAMPS WITH CUSHIONS PROVIDE PIPE TEMPERATURE AND HANGER "PHD" MANUFACTURING MODEL PIPE HANGER RING PIPE UNIONS DIELECTRIC 150 PSI PRESSURE = ROD 2501-2514 _ I.T.T. GRINNELL FIG.260 IF REQUIRED FOR RELIEF VALVE DISSIMILAR METALS._ WITH TEST LEVER SIZED WITH AGA/CGA = _ DRAIN VALVE BY HEATER MAUF CT. TEMPERATURE RATING 107 OVEREAM HEATING INPUT. _ = PIPES 2112 & SMALLER PIPES 3" & LARGER THERMOSTAT AND PRESSURE REGU- -PROVIDE A HARD = = NOTE: 1. PROVIDE COPPER PLATING ON HANGER BETWEEN LATOR FURNISHED COPPER RELIEF VALVE DISCHARGE STEEL AND COPPER WHERE UNINSULATED COPPER WITH WATER HEATER. LINE FULL SIZE OF — — — — — — _IL PIPING IS USED. 3/4' PLYWOOD BELOW VALVE OUTLET RUN TO TERMINATE OVER _ U _ u _ u _ U _ d _ U _U— _ _ 2. PROVIDE ADDITIONAL HANGERS ON EACH SIDE OF A WATER HEATER DRAIN PAN AS PLATFORM. 2' SAFE PAN. - v INSULATED PIPE LINE WITH - METAL CHANNEL STRUT WALL WHERE THE PIPING PENETRATES THE WALL. PIPE CLAMP. PROVIDE 2' DEEP STAINLESS PROVIDE 2" CHANNELS � MINIMUM INSULATION SHIELD ON 3" 3. ALL INTERIOR HANGERS SHALL BE GALVANIZED STEEL SAFEPAN. OF RUSTPROOFPRIMER NOTES; AND LARGER. INCLUDING THREADED RODS, NUTS AND BOLTS. PROVIDE A DRAIN SF BETWEEN 1. TRAPEZE HANGERS SHALL NOT BE USED ON STORM, PAN, RU OVERFLOW THREADED RODS TO SUPPORT WATER HEATER OVERFLOW STORM OR SANITARY PIPING SYSTEMS. 4. ALL PLUMBING TRADE ITEMS SHALL BE INDIVIDUALLY LINE AT�X4' SLOPE SAFEPAN. 2. PROVIDE ADDITIONAL HANGERS ON EACH SIDE OF A AND RIGIDLY SUPPORTED FROM STRUCTURE ABOVE AND TERMINATE OVER WALL WHERE THE PIPING PENETRATES THE WALL. INDEPENDENT OF ALL OTHER TRADES. (DO NOT HANG ANFLOOR DRAIN WITH WATER HEATER - MAXIMUM 3. ALL INTERIOR HANGERS SHALL BE GALVANIZED PLUMBING ITEMS FROM ANOTHER TRADE.) OF 30 GALLON CAPACITY. INCLUDING THREADED RODS, NUTS AND BOLTS. 4. ALL PLUMBING TRADE ITEMS SHALL BE INDIVIDUALLY AND RIGIDLY SUPPORTED FROM STRUCTURE ABOVE INDEPENDENT OF ALL OTHER TRADES. (DO NOT HANG PIPING ARRANGEMENT SHOWN IS SCHEMATIC. ADJUST TO SUIT FIELD CONDITIONS. REFER TO ISOMETRIC RISER FOR PIPE SIZES. PLUMBING ITEMS FROM ANOTHER TRADE.) SET HEATER THERMOSTAT AT 120°F. PLATFORM MOUNTED ELECTRIC TRAPEZE PIPE HANGER U.L./F.M. APPROVED CONCRETE WATER HEATER SCALE: - NONE INSERT PIPING HANGER DETAIL N 0 T TO SCA _ MOV rrr� �I E OF ' t! Smith Seckman Reid, Inc. 600 West Hillsboro, Suite 300 Deerfield Beach, FL 33441 (954)421-1260 FAX: (954) 421-1466 www.ssr-inc.com Firm Certification - EB-0000857 Dennis Davis PE - 58588 John E. Moulder PE - 33200 SSR JOB # 1137001.0 cv COO o� O 2,' q b y F3 y Cn N CIO Cn O C� O LL 1 U m U O Cn C'0 _U -�--� 70 Cll � 0 Cn O ^� CV LL T Project No. 11006,00 P5.1 ©2011 BHIPK Architects, Inc. s FAN SCHEDULE 0" c o+ N O / L U N :2 E a- /00 O_ N O O M M / LIDJ 0 N / ti E N o � � o .Ln 0 w J J L� LL IZ O 0 I W [1 M �1 = BELT GUARD ®= 18' HIGH ROOF CURB 15 = THREE-PHASE DISCONNECT SWITCH PRE = POWER ROOF EXHAUSTER O = INERTIA BASE O = WEATHERPROOF HOUSING 16 = IN FAN HOUSING PREWIRED DISCONNECT SWITCH IN PRS = SWSI = POWER ROOF SUPPLY FAN SINGLE WIDTH, SINGLE INLET O = LINED HOUSING 10 = MOTORIZED INLET DAMPERS 17 FAN HOUSING DWDI = BUS = DOUBLE WIDTH, DOUBLE INLET BELTED VENT SET q O = INLET SCREEN 1 1 = MOTORIZED OUTLET DAMPERS = OUTLET GRAVITY DAMPERS C.T. = CONTROL TRANSFORMER 0 = OUTLET SCREEN 12 = MOTORIZED INLET VANES E.P. = EMERGENCY POWER EXP. = EXPLOSION PROOF MOTOR & ©= WALL SHUTTER 13 = INLET GRAVITY DAMPERS NON -SPARKING WHEEL = SAFETY CAGE 14 = ACCESS DOOR & DRAIN (1 ) - HIGH EFFICIENCY MOTOR (SEE SPECS (2) - INCLUDES WEIGHT OF INERTIA BASE MANUFACTURER FAN DIA./ MOTOR OPERATING (DENT. SYSTEM TYPE MODEL N0. CFM S.P. FAN RPM MIN RPM ELECT. FAN ACCESS ISOLATORS WEIGHT (2) REMARKS H.P. EF-1 EXHAUST CEILING SP-B150 150 0.75 1050 129w 1050 115/1/60 - SPRING 10 INTERLOCK WITH AHU CONTROLLER AIR DEVICE SCHEDULE 1. AIR DEVICE SIZES & SCHEDULED AIRFLOW ARE BY THIS SCHEDULE UNLESS OTHERWISE NOTED ON HVAC FLOOR PLANS. 2. BRANCH & OPTIONAL BRANCH DUCT SIZES ARE BY THIS SCHEDULE UNLESS OTHERWISE NOTED ON HVAC FLOOR PLANS. 3. ALL AIR DEVICES INSTALLED IN INACCESSIBLE AND/OR DRYWALL CEILINGS SHALL BE PROVIDED WITH MANUAL OPPOSED BLADE DAMPERS. 4• ALL AIR DEVICES INSTALLED IN ACCESSIBLE AND/OR LAY -IN CEILINGS SHALL HAVE A MANUAL VOLUME DAMPER INSTALLED IN THE BRANCH TAKE -OFF. 5. MAXIMUM PRESSURE DROP FOR ALL AIR DEVICES SHALL NOT EXCEED 0.10 IN. W.G. BRANCH 6. ALL AIR DEVICES SHALL BE WHITE UNLESS OTHERWISE NOTED. MAIN RUNOUT 7. MAXIMUM NC RATING FOR ALL AIR DEVICES SHALL NOT EXCEED 25. 8. ALL AIR DEVICES SHALL BE ALUMINUM CONSTRUCTION UNLESS OTHERWISE NOTED. MVD 9. THROW VALUES ARE GIVEN FOR TERMINAL VELOCITIES OF 150, 100 & 50 FPM RESPECTIVELY. MARK I MFGR &MODEL I CFI RANGE I MODULE FACE (SIZE I NECK SIZE BRANCH DUCT SIZE I THROW SQUARE TO ROUND ADAPTER DIFFUSER OR GRILLE REMARKS A TITUS TMS-AA 0 - 100 12x12 / 12x12 6"m 8x6 / 610 2-3-6 B TITUS TMS-AA 101 - 200 24x24 / 24x24 8'(D 10x6 / 810 3-5-9 C TITUS TMS-AA 201 - 325 24x24 / 24x24 1040 12x8 / 10'm 4-6-13 D TITUS TMS-AA 326 - 525 24x24 / 24x24 12'0 14x10 / 1210 5-8-16 E TITUS TMS-AA 526 - 700 24x24 / 24x24 14"0 16xIO / 1410 6-10-19 F TITUS 300FL 0 - 125 8x6 / IOx8 8x6 8x6 / - 8-11-16 G TITUS 300FL 126 - 300 12x8 / 14x10 12x8 12x8 / - 12-18-25 H TITUS 300FL 301 - 550 18xlO / 20x12 18x10 18x10 / - 16-23-34 1 TITUS 50F 0 - 180 8x8 / 1Ox10 8x8 lOx6 / 8'0 - 2 TITUS 50F 181 - 300 10x10 / 24x24 1Ox10 12x8 / 1010 - 3 TITUS 50F 301 - 450 12x12 / 24x24 12x12 14x10 / 120 - 4 TITUS 50F 451 - 650 14xl4 / 24x24 14x14 16xlO / 1410 - 5 TITUS 50F 651 - 850 16xl6 / 24x24 16xl6 22x10 / 16V - 6 TITUS 50F 851 - 1000 18x18 / 24x24 l8x18 28x10 / 1810 - 7 TITUS 50F 1001 - 1900 18x18 / 24x24 22x22- 8 TITUS 350FL 0 - 125 8x6 / IOx8 8x6 8x6 / - - 9 TITUS 350FL 126 - 285 12x8 / 14xIO IOx8 12x8 / - - 10 TITUS 350FL 286 - 440 18x10 / 20x12 18x10 18x10 Smith M150"Seckman k Reid, Inc. 600 West Hillsboro, Suite 300 Deerfield Beach, FL 33441 (954) 421-1260 FAX: (954) 421-1466 www.ssr-inc.com Firm Certification - EB-0000857 Dennis Davie PE - 68588 John E. Moulder PE - 33200 SSR JOB # 1137001.0 v o Q 0 b N o ~~ � N 122. y • ma ^r..I d to n o - L Q (D N CtS _Q C!) 0 CL� _0 LL 1 0) .:3 m 0 U_ 0 M U_ 70 L / 0//� VJ VJ (10 c) 0 (13 =N T Project No. 11006.00 M0.2 02011 BHIPNArcUeds, Inc. NO -- -___ Z.:..r •r_ i- i is T � _ ?}�Rt�• l i .r ;. �' S-i� - -... ..: .N'.. - ..� . ...' .. II I I . i �_ �.• r1 ��1tj „p...:n' iu ,1ci. t ' F' �.-e �' .R�il.�' r..�. ��'.� ._. _-. . � .- .. ,.... r � ,:.•;;� �...y .�l�5f tE[4� :, �:' . .�l-r..�.a:S�wt.:... i..,I '. _ .,� �L.r.. ,,. . N. ?�.,, .,.,tea - . -� �, �, �..:.�9 �. _ '.� .. __.._,.. .:AIr ��i'a"a n, lr .. �1f..P•. 15010 - BASIC MECHANICAL REQUIREMENTS A. CODES & REFERENCES 1. FLORIDA STATE BUILDING CODE 2007 (WITH 2O09 AMENDMENTS). 2. SMACNA 3. NFPA 101 (2006) 4. NFPA 90A (2002) B. SCOPE OF WORK 1. PROVIDE ALL REQUIRED PERMITS. LABOR, MATERIAL AND EQUIPMENT REQUIRED TO COMPLETE THE SCOPE OF THE PROJECT SHOWN ON THE DRAWINGS COMPLETE AND READY FOR OCCUPANCY AND USE BY OWNER. THE WORK SHALL INCLUDE BUT IS NOT LIMITED TO: a. REMOVAL. RELOCATION AND RE -INSTALLATION OF EXISTING EQUIPMENT AND SYSTEM. b. CONNECTIONS TO EXISTING OR NEW EQUIPMENT AND SYSTEMS. c. MODIFICATION OF EXISTING DUCTWORK, TEMPERATURE CONTROLS, AND LIFE -SAFETY SYSTEMS. d. CUTTING AND PATCHING TO REMOVE EXISTING OR INSTALL NEW WORK. e• CLEANING AND TESTING. f. INSTRUCTION TO OWNER'S PERSONNEL. 2, PROVIDE ALL BUILDING PENETRATIONS REQUIRED TO COMPLETE PROJECT. ALL PENETRATIONS SHALL BE PATCHED AND SEALED WATERTIGHT. MAINTAIN FIRE RATINGS OF EXISTING STRUCTURE. 3. PROVIDE ALL NECESSARY DUCT, EQUIPMENT, PIPE SUPPORTS AND MATERIALS REQUIRED FOR INSTALLATION PER THE REQUIREMENTS OF LOCAL, STATE OR FEDERAL CODES. C. REQUIRED SHOP DRAWINGS 1. INSULATION. 2. AIR DEVICES. 3. VALVES. 4. DUCTWORK COORDINATION DRAWINGS. 5. CONTROLS. D. RECORD DRAWINGS 1. THE CONTRACTOR SHALL MAINTAIN AN ACCURATE RECORD OF ALL CHANGES MADE TO THE CONTRACT DOCUMENTS. 2.THE CONTRACTOR SHALL PROVIDE THE ENGINEER 2 SETS OF COMPLETED RECORD DRAWINGS. 3.THE PROJECT WILL NOT BE CONSIDERED COMPLETE UNTIL ACCURATE RECORD DRAWINGS ARE DELIVERED. E. SUBSTITUTIONS 1. EQUIPMENT AND DESIGN OF SYSTEMS INDICATED ON THE DESIGN DRAWINGS AND WITHIN THESE SPECIFICATIONS SHALL BE CONSIDERED AS 'SPECIFIED STANDARD' OF QUALITY. NO SUBSTITUTIONS SHALL BE MADE WITHOUT PRIOR WRITTEN APPROVAL OF THE ENGINEER 10 DAYS PRIOR TO BID DATE. 2.ANY DEVIATION FROM SPECIFIED EQUIPMENT THAT AFFECTS THE ELECTRICAL REQUIREMENTS SHALL BE COORDINATED BY THE MECHANICAL CONTRACTOR AND EQUIPMENT VENDOR WITH THE ELECTRICAL CONTRACTOR PRIOR TO SUBMITTING BIDS. F. ACCESS PANELS - FURNISHED BY MECHANICAL CONTRACTOR. INSTALLED BY GENERAL CONTRACTOR. 1. PROVIDE ACCESS TO ALL SERVICEABLE EQUIPMENT IN WALLS AND CEILINGS. 2. MICOR STYLE M FOR DRYWALL. 3. MICOR STYLE K FOR PLASTER. 4. MINIMUM SIZE 16'x16' . 5. NYSTROM. KARP, J.L. INDUSTRIES OR WILLIAMS PAINT. G. FLASHINGS AND COUNTER FLASHINGS 1. FURNISH MATERIALS AND COORDINATE INSTALLATION FOR ALL PENETRATIONS OF ROOF BY ALL DUCT AND PIPE. 2. SHEET METAL - 24ga. ASTM A525 . 3. SHEET LEAD 6 Ibs PER SO. FT. (WHERE ALLOWED) 4. STAINLESS STEEL 20 ga. 5. SHEET COPPER 24 oz PER SQ. FT. H. MECHANICAL SYSTEMS CLEANING 1. CLEAN AND TOUCH UP ALL FACTORY FINISHES. 2. FLUSH ALL HVAC SYSTEMS BEFORE CONNECTION TO EQUIPMENT. 3. CLEAN ALL CLOSED HVAC SYSTEMS WITH ALKALINE CLEANER CIRCULATED FOR 72 HOURS. I. CLEANING TESTING AND ADJUSTING 1. THE MECHANICAL CONTRACTOR, AT HIS EXPENSE, SHALL CLEAN, REPAIR, ADJUST. CHECK, BALANCE AND PLACE IN SERVICE THE VARIOUS SYSTEMS HEREIN SPECIFIED WITH THEIR RESPECTIVE EQUIPMENT, ACCESSORIES AND PIPING. HE/SHE SHALL FURNISH ALL LABOR, MATERIALS, EQUIPMENT AND TOOLS REQUIRED TO PERFORM TESTS REQUIRED BY THESE SPECIFICATIONS AND BY THE GOVERNING AUTHORITIES. 2. NO WORK SHALL BE COVERED OR CONCEALED UNTIL PROPERLY INSPECTED AND TESTED. F. HANGERS AND SUPPORTS 1. PROVIDE ALL NECESSARY DUCTWORK, HANGERS, RODS, CLAMPS AND ATTACHMENTS TO PROPERLY INSTALL AND SUPPORT DUCTWORK, PIPING AND EQUIPMENT FROM THE BUILDING STRUCTURE. 2. PROVIDE ANY ANGLE IRON OR UNISTRUT AND SUSPENSION RODS REQUIRED TO INSTALL DUCTWORK. 3. ALL SUPPORTS EXPOSED TO OUTDOORS SHALL BE CLEANED, PRIMED AND PAINTED TO PREVENT RUSTING. FINISH COLOR AS SELECTED BY OWNER. 4. THE USE OF BAILING WIRE OR PERFORATED METAL STRAPPING IS NOT PERMITTED FOR SUPPORTS. G. WARRANTY/GUARANTEE 1. THE CONTRACTOR SHALL WARRANTY/GUARANTEE AND MAINTAIN THE STABILITY OF WORK AND MATERIALS AND KEEP SAME IN PERFECT REPAIR AND CONDITION OF THE PERIOD OF ONE YEAR. 2. DEFECTS OF ANY KIND DUE TO THE FAULTY WORK OR MATERIALS APPEARING DURING THE ABOVE MENTIONED PERIOD MUST BE IMMEDIATELY MADE GOOD BY THE CONTRACTOR AT HIS OWN EXPENSE TO THE ENTIRE SATISFACTION OF THE OWNER AND ENGINEER. SUCH RECONSTRUCTION AND REPAIRS SHALL INCLUDE DAMAGE TO THE FINISH OR FURNISHING OF THE BUILDING RESULTING FROM THE ORIGINAL DEFECT OR REPAIR THERETO. 15250 - INSULATION A. INSULATION, ADHESIVES, COATINGS, SEALERS. TAPES, ETC. SHALL HAVE A FLAME SPREAD OF 25 OR LESS AND SMOKE DEVELOPMENT OF 50 OR LESS IN ACCORDANCE WITH ASTM E-84, NFPA 225, UL 723 AND MEET THE REQUIREMENTS OF NFPA 90A. ALL INSULATING R-VALUES TO MEET THE REQUIREMENTS OF THE FLORIDA ENERGY CODE. B. SEMIRIGID BOARD TYPE DUCT INSULATION 1.51b DENSITY, CERTAINTEED 1 B-300. JOHNS MANVILLE, KNAUF, OWENS CORNING: GLASS FAB & MASTIC ALL JOINTS, R-6. I. ALL SUPPLY, RETURN AND OUTSIDE AIR WHERE EXPOSED AND IN MECHANICAL ROOMS. 2.MINIMUM DUCT INSULATION THICKNESS AND R VALUES ARE AS FOLLOWS: a. SUPPLY AND RETURN AIR IN UNCONDITIONED SPACE: 2' (R-6 MINA.) c. OUTSIDE AIR: 2' (R-6 MINA.) d. SUPPLY AIR IN CEILING RETURN DUCTWORK: 1.5' (R-6 MINA.) 15910 - SHEET METAL ACCESSORIES A. AIR INLETS AND OUTLET. 1. REFER TO SCHEDULE. 2. ALL ALUMINUM CONSTRUCTION. 3. ACCEPTABLE MANUFACTURERS: TITUS, PRICE, METAL-AIRE. CARNES, ANEMOSTAT, NAILOR, POTTORFF. 15990 - TEST AND BALANCE A. PROVIDE COMPLETE TEST AND BALANCE OF ALL AIR SYSTEMS IN ACCORDANCE WITH NEBB (NATIONAL ENVIRONMENTAL BALANCING BUREAU) OR AABC (ASSOCIATED AIR BALANCE COUNCIL) STANDARDS. B. TEST AND BALANCE FIRM SHALL BE: 1. A LOCAL FIRM WITH A MINIMUM OF 10 YRS HOSPITAL EXPERIENCE C. CONTRACTOR SHALL: 1. VISIT SITE AT START OF PROJECT AND COORDINATE REQUIRED BALANCING EQUIPMENT AND DAMPERS WITH MECHANICAL CONTRACTOR. 2. AIR SYSTEMS: a. MAKE CHANGES TO BELTS, PULLEYS, DAMPERS, VOLUME BOXES, ETC. TO OBTAIN DESIGN CONDITIONS AS REQUIRED BY TAB PROCEDURES. b. BALANCE SUPPLY, RETURN AND EXHAUST AIR OUTLETS WITHIN 10% OF DESIGN WHILE MAINTAINING REQUIRED PRESSURE RELATIONSHIPS. RECORD DESIGN AND ACTUAL TOTALS. c. MEASURE AND REPORT FAN RPM, FAN SUCTION PRESSURE, FAN DISCHARGE PRESSURE, FAN TOTAL PRESSURE AND PRESSURE DROP ACROSS COMPONENTS. DESIGN AND ACTUAL SUPPLY, RETURN, OUTSIDE AND EXHAUST AIR. d. ACTUAL AND DESIGN NAMEPLATE AMPERAGE ON FAN MOTORS. e. PRESSURE DIFFERENTIAL ACROSS DUCT SMOKE DETECTORS. f. ADJUST FANS FOR LOWEST STATIC PRESSURE REQUIRED TO DELIVER TO OUTLETS AS NOTED IN NEBB OR AABC PROCEDURES. 4. CONFIRM OPERATION OF ALL CONTROLS, MANOMETERS AND SENSING DEVICES. 5.ON AHCA REVIEWABLE PROJECTS PROVIDE WRITTEN REPORT AT LEAST ONE WEEK BEFORE FINAL INSPECTION AND PROVIDE A TECHNICIAN DURING FINAL INSPECTION OF PROJECT. 6. CONTRACTOR SHALL PROVIDE FINAL SHEAVE CHANGE OUT AND ADJUSTMENT FOR MAXIMUM AMPRAGE TO INCLUDE DIRTY FILTER ALLOWANCE LOADING ALLOWING THE VFD TO RAMP UP IN RESPONSE TO FILTER LOADING. F. BALANCING DAMPERS (RUSKIN MD-35 SERIES) 1. GENERAL -IN ALL DUCTWORK SYSTEMS. PROVIDE DAMPERS FOR PROPER CONTROL AND BALANCING OF AIR QUANTITIES. CONCEALED DAMPERS SHALL HAVE CONCEALED DAMPER REGULATOR. ALL COMPONENTS FOR PROPER OPERATION; (i.e. GEARS. LINKAGES, CABLE, ETC.) SHALL BE INCLUDED. 2. TYPE: FACTORY MANUFACTURED ONLY, OPPOSED BLADE FOR 12' AND LARGER AND SINGLE BLADE UP TO 11' IN HEIGHT. 3. MATERIAL: STEEL, 3V TYPE BLADES MOUNTED IN STEEL CHANNEL FRAME. 4. SHAFT: 3/1 SQUARE ROD OPERATOR WITH END BEARINGS AND GASKET SEAL AT DUCT PENETRATIONS. TERMINATE SHAFT IN DAMPER FRAME WITH BUSHINGS. 5.OPERATOR: LOCKING QUADRANT HANDLE WITH DAMPER POSITION INDICATOR AND INSULATION STAND OFF MOUNTING BRACKET FOR EXTERNALLY INSULATED DUCTWORK. 6. MANUFACTURER: RUSKIN MODEL MD-35 SERIES OR EQUAL BY AIR BALANCE, INC. OR GREENHECK. G. ACCESS DOORS 1. ACCEPTABLE MANUFACTURERS: a. RUSKIN MODEL ADH22. b. VENCO CAD-10. c. GREENHECK HAD-10. 2. SIZE ACCESS DOOR AS FOLLOWS: a. DUCT SIZES UNDER 12% DOOR SIZED SUFFICIENT TO EQUIPMENT OR REPLACE FUSIBLE LINK. b. DUCT SIZES 12' TO 20% 12'xl2' DOOR. c. DUCT SIZES 20' TO 36% 18'xl8' DOOR. d. DUCT SIZES 36' AND ABOVE: 24'x24' DOOR. 3. USE DOUBLE PANEL CONSTRUCTION, TWO SHEETS OF AT LEAST 24 GAUGE GALVANIZED STEEL WITH 1' THICK INSULATION BETWEEN PANELS. 4. MOUNT DOORS IN A RIGID FRAME OF AT LEAST 22 GAUGE FORMED GALVANIZED STEEL OR ALUMINUM. 5. PROVIDE LATCHES THAT PERMIT EASY REMOVAL OF ACCESS DOOR WHILE MAINTAINING POSITIVE CLOSING AND MINIMUM LEAKAGE. 6. PROVIDE SPONGE RUBBER GASKETS FOR ALL DOORS. 7. IN ACCORDANCE WITH NFPA 90A. IDENTIFY EACH ACCESS DOOR WITH 1/1 HIGH STENCILED LETTERS AS 'FIRE DAMPER', 'SMOKE DAMPER'. OR 'COMBINATION FIRE/SMOKE DAMPER'. H. BRANCH CONNECTIONS -CLINCH LOCK TYPE NOT PERMITTED. 15970 - TEMPERATURE CONTROLS A. NEW CONTROL SYSTEM TO EXISTING EQUIPMENT AND PROVIDE ALL MODIFICATIONS NECESSARY FOR A FULLY FUNCTIONING SYSTEM. B. AIR HANDLING UNIT AND CONDENSING COILS. 1. THE EXISTING CONTROL SYSTEM IS TO BE MODIFIED BY THE OWNERS EXISTING CONTROL VENDOR. 2.CONTROL CONTRACTOR SHALL PROVIDE ALL WIRING REQUIRED FOR THE CONTROL SYSTEM TO OPERATE. IF THE JOB CONTAINS SMOKE DAMPERS THEY SHALL ALSO BE WIRED BY T.C.C. 3. MOUNT THERMOSTATS 48' A.F.F. ALIGN WITH LIGHT SWITCHES, DOOR SWINGS AND OTHER WALL MOUNTED DEVICES. 4. COORDINATE FINAL LOCATION OF THERMOSTATS WITH THE OWNER PRIOR TO INSTALLATION. 3 I(: V: OF NAL Smith IN516k Seckman Reid, Inc. 600 West Hillsboro, Suite 300 Deerfield Beach, FL 33441 (954)421-1260 FAX: (954) 421-1466 www.ssr-inc.com Firm Certification - EB-0000857 Dennis Davie PE - 58888 John E. Moulder PE - 33200 SSR JOB # 1137001.0 �. I�' i. ...�V„ � LJ. ..1. .� i '.i i .. �i' .. .. -'..�1 ._ Jl���:ii .1�.. n r _�. . 'I. II - rl. .�i•I.J rV.lt ..i ��:l: l �I_-'1NLV.J 11 i q'+ � 1. -l• a «�n� � .. .,. s'.. c3 ti o . R N ci� _R � I-C> a a 0 zt b a A 9 e 0 C!) Q Qa N CIS -IF-+ Cn 0 Cz 0 _L_ _0 U_ I 0) .D CD 0 U_ C Cz CZ _ U a) U rQ � v U Cz Co 0 =N T Project No. 11006.00 M0.3 ®2011 BNIPSArchitects, Inc. FIRST FLOOR PLAN - DEMOLITION - HVAC I�Ir��� DEMOLITION SCOPE OF WORK CONTRACTOR SHALL DEMOLISH ALL EXISTING DUCTWORK IN THE AREA OF WORK AND PROVIDE ALL NEW DUCTWORK AS SHOWN.E/A DUCTWORK SHALL BE DEMOLISHED TO THE CLOSET POINT TO THE NEW CONNECTIONS ON PLANS. EXISTING AHU/CU & EDH'S SHALL REMAIN AND BE REUSED. EQUIPMENT SHALL BE PROTECTED DURING CONSTRUCTION AND AHU SHALL NOT BE USED AS TEMPORARY CONSTRUCTION AIR CONDITIONING DURING DEMOLITION. SEE DEMO KEY NOTES. w o J Z W U7 � LLJ Q O O DEMOLITION KEY NOTES ( DEMOLISH ALL DUCTWORK FROM AHU UNIT TO END OF DUCTWORK RUNS. 02 DEMOLISH ALL FLEX DUCT AND GRILLES IN THE BOXED AREA. (3) AHU/CU SHALL REMAIN. WRAP AND SEAL S/A, R/A AND O/A UPON DISCONNECTION FROM UNIT DURING DEMOLITION AS SO THAT NO DUST AND DIRT ENTER UNIT. ® EDH-1 & 2 REMAIN. DISCONNECT FROM DUCTWORK AND CLEAN. VACUUM COILS AND CHECK ALL ELECTRICAL CONNECTIONS FOR FRAYED OR DAMAGED WIRES. STORE ON SITE IN AN ENLOSED BOX AS SO THAT NO DUST OR DIRT ENTER COILS. 50 EXISTING REFRIGERANT LINES SHALL BE INSPECTED AND SHALL REMAIN. PROTECT LINES FROM ANY DAMAGE DURING DEMOLITION. © EXISTING CU UNIT TO REMAIN. WASH & CLEAN EVAP COIL. CHECK REFRIGERANT LEVEL. 07 EXISTING S/A AND R/A DUCTWORK IN LOWER OFFICE TO BE CUT AND CAP OUTSIDE OF WORK AREA. COORDINATE DEMO OF DUCTWORK WITH OUTLINE OF NEW OFFICE AREA AND SITE CONDITIONS. ® CUT AND CAP E/A DUCTWORK AT BASE OF RISER. DO NOT DAMAGE DUCT CONNECTION AT EXISTING CEILING HARD LID. Q REMOVE ALL OUTSIDE AIR DUCWORK. EXISTING LOUVER TO REMAIN. DEMOLITION LEGEND F L DESCRIPTION EXISTING TO REMAIN EXISTING TO BE REMOVED REMOVE EXISTING TO THIS POINT MOU E •f%��i 0. TE OF O R1 � Q; Cj. Smith Seckman Reid, Inc. 600 West Hillsboro, Suite 300 Deerfield Beach, FL 33441 (954) 421-1260 FAX: (954) 421-1466 www.ssr-inc.com Firm Certification - EB-0000857 Dennie Davie PE - 58588 John E. Moulder PE - 33200 SSR JOB # 1137001.0 o� o o tl p N 0 b � O ti o q 0 U) I N (z W Q ctj _I _O LL U I m I O m O (a) `~ C) O I (� _U 7C) �CC C O U) O1,e' LL (CS O C. CV LL ProjectNo. 11006.00 m 1 .1 ©2011 BHIPSArchitects, Inc. 0 2 200 E 200_ FIRST FLOOR PLAN - NEW CONSTRUCTION - HVAC �I�I ILA NEW CONSTRUCTION SCOPE OF WORK CONTRACTOR SHALL PROVIDE A NEW WORKING HVAC SYSTEM CONNECTED TO EXISTING EQUIPMENT. ALL EXISTING EQUIPMENT SHALL BE FIELD TESTED AND INSPECTED TO CONFIRM IT IS PROPER WORKING ORDER. PROVIDE NEW DUCTWORK, FAN(S), CONTROLS, GRILLES, DAMPERS, ETC AS SHOWN. PROVIDE NEW CONTROLLER AS SHOWN AND PROVIDE ONSITE TRAINING TO OWNERS STAFF AS NEEDED PRIOR TO CLOSING OUT THE JOB. NEW EXHAUST DUCTWORK SHALL CONNECT TO EXISTING EXHAUST DUCTWORK. CONFIRM EXISTING DUCTWORK IS IN PROPER WORKING ORDER. CONTRACTOR SHALL VERIFY E/A DUCT PENETRATION THRU FIRE RATED LID MEETS CODE. CONFIRM NO DAMAGE EXISTINGS AROUND DUCT PENETRATION AND THAT EXISTING DAMPER/SEALANT IS IN PROPER WORKING ORDER. REPAIR AS NEEDED. NEW O/A DUCTWORK TO BE CONNECTED TO EXISTING INTAKE LOUVER. DEM 117 & DEXA 118 S/A GRILLES TO BE RELOCATED AND DUCTWORK EXTENDED. PROVIDE NEW R/A GRILLES. CL 0 0 J 0 (V 0 Ln O J nI �.. A 50 �h L J V 1 C 250 B 125 EXISTING AHU-1 1 6 36X14 R/A DN TO UNIT EXISTING Fo-1 CU-I KEY NOTES EXISTING AHU/CU TO REMAIN. CONNECT NEW DUCTWORK TO EXISTING UNIT. Q2 ROUTE NEW DUCTWORK TO EXISTING HEATERS AND CONNECT. PROVIDE DUCTWORKING CONNECTIONS AS REQUIRED. REFER TO DETAIL. �3 ROUTE NEW E/A DUCTWORK TO EXISTING CONNECTION TO ROOF JACK. UNDER CUT DOOR. ® INSTALL MP581 WITH FREEZE PROTECTION ON UNIT. PROVIDE INSULATED BACKING FOR CONTROLS AT WALL. �5 EXISTING OUTSIDE AIR INTAKE LOUVER. CONTRACTOR SHALL CLEAN LOUVER AND PROVIDE NEW INSULATED PLENUM BOX FOR E/A DUCT CONNECTION. CONNECT 1OX10 DUCT FROM LOUVER TO R/A DUCT CONNECTIONS AT AHU R/A RISER. © PROVIDE O/A BALANCING DAMPER AT O/A TO R/A DUCTWORK CONNECTION. DAMPER TO BE INSTALLED IN O/A DUCT 4 FT FROM R/A DUCT CONNECTION. t�7 RELOCATE EXISTING S/A GRILLE. EXTEND DUCTWORK AS REQUIRED. ® PROVIDE (2) NEW R/A GRILLES. EXTEND EXISTING DUCTWORK AND CONNECT. NEW CONSTRUCTION LEGEND SYMBOL DESCRIPTION - EXISTING TO REMAIN NEW CONSTRUCTION CONNECT TO EXIST. AT THIS POINT `��1111toll/// MOUE N 33 r S oNAL,�,,`,, Smith Seckman Reid, Inc. 600 West Hillsboro, Suite 300 Deerfield Beach, FL 33441 (954)421-1260 FAX: (954) 421-1466 www.ssr-inc.com Firm Certification - EB-0000857 Dennis Davie PE - 58588 John E. Moulder PE - 33200 SSR JOB # 1137001.0 ev c� o� 6 o o o -4- d .s do 0 C� L Cu N _ Q O U � CCU -0 _ _O LL O Cn — O m U (a) z 0 U CCS 7C) � CU I O Cf) _O L - 05 -M O Cn -IL CV LL T— Project No. 11006.00 M2. 1 ©2011 BHIPKArchitects, Inc. Q 0 "TAP -OUT' EITHER SIDE OR BOTTOM OF DUCT. TOP "TAP-OUT"IS NOT ACCEPTABLE ELECTRIC BOOSTER COIL SEE SCHEDULE FOR FLANGED OR SLIP -IN MOUNTING ---i MIN. 4 FT. STRAIGHT DUCT UPSTREAM & DOWNSTREAM OF DUCT REHEAT COIL —ram 300 THERMAFLEX MKE OR FLEXMASTER 8M 24 GA. INSULATED GALVANIZED SHEET METAL BOX I TERMINALi °- I BOX 200 I �� 6' MIN. I � AIR FLOW 12x12 MIN. SIZE ' +` ACCESS PANEL BOTTOM OR SIDE MIN. 3'-6' WORKING CLEARANCE TO SERVICE TERMINAL BOX AND COILS CEILING RETURN GRILLE RETURN DUCT SHOE TAP WITH BALANCE DAMPER SECURING STRAP PANDUIT (OR EQUAL) VOLUME DAMPER REQUIRED WHERE DAMPER AT DUCT BRANCH IS INACCESSIBLE. NOTE: INSULATE RETURN DUCTWORK PER SPECS. 'TAP -OUT' EITHER SIDE OR BOTTOM OF DUCT. TOP 'TAP -OUT' IS NOT ACCEPTABLE --\ THERMAFLEX MKE OR FLEXMASTER 8M 6' MIN. CEILING NOTE FOLLOW MFR'S INSTRUCTIONS FOR INSTALLATION OF SUPPLY DIFFUSER IN CEILING 0 SUPPLY DUCT SHOE TAP WITH BALANCE DAMPER ,,—SECURING STRAP PANDUIT (OR EQUAL) SHEET METAL SCREW (TYPICAL) SUPPLY DIFFUSER WITH INSULATED BACK PANEL DUCT MOUNTED ELECTRIC I3 I RETURN RDUCTWOK GRIL�EN F ENECTIONDU�T) 12 I �SUPPWUCT�RDIFF�SERC(F�EXTDUCT) I � REHEAT COIL S SLIP OR U CLIP OPTIONAL ALL SUCH CONNECTIONS TO BE SEALED I � I VOLUME DAMPER w = 4' MIN. VOLUME DAMPER tAA SQUARE THROAT ELBOW OPTIONAL VOLUME DAMPER D3 = 4' MIN. NOTE: VOLUME CONTROL SHOULD BE BY BRANCH DAMPERS. IF A SPLITTER IS SHOWN IN THE DESIGN ITS LENGTH SHOULD BE 1.5 W OR 1.5 D3. PARALLEL FLOW BRANCHES 0 Cn CV 0 N 0 Ln O J LJ_ O W AIR FLOW 1 NOTE: 1. TRANSITION TO MAKE EQUAL ELL'S. 61LOW PRESSURE DUCT TEE DETAIL *IMPORTANTI POST TENSION SLAB. *IMPORTANTI PREVENT EXERCISE EXTREME CAUTION IN BENDING OF STRAP AT PLACING INSERTS TO AVOID STEEL 900 BEND UNDER LOAD TENSION CABLES. 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 = o O 0 0 0 0 0 O 0 0 O O 0 0= o 0 0 0 = o 0 0 0 0 0 0 r::�\WASHER EXPANSION SHIELDS **CONCRETE ANCHORS 0 0 O O O O 0 O O 0 O o 0 0 0 O 0 O 0 O « IMPORTANTI PREVENT C BENDING OF STRAP AT 900 BEND UNDER LOAD. 3a* EXPANSION NAIL 0 0 0 O O O O O O O 0 O O O O O 0 0 0 0 0 0 0 0 O O 0 0 0 O O o 3b* HANGER STRAP 0 0 O O 0 O O O O O O 0 0 0 0 0 0 O O o STRAP ASHER NUT BAND OF SAME SIZE AS HANGER STRAP ML 1 LI ATI\1\M 1 G LOCON HANGERS FOR STACKED DUCTS REINFORCEMENTS MAY BE USED FOR ATTACHMENT IF IT QUALIFIES FOR BOTH DUTIES DO NOT EXCEED LOAD RATING FOR METHOD USED -THREADED ROD SUPPLY, RETURN, & EXHAUST TYPICAL-7 BOLTED 31, DUCTS & LARGER MAX. 10'-0' O.C. SCREWS SILOW PRESSURE DUCTWORK HANGER DETAIL z N xa aCL M (N Tt "' 0 ```� •••.•..,... 3 • * �01 OF w� S` ,•� a R o••; ®NAL�E���. Smith Seckman Reid, Inc. 600 West Hillsboro, Suite 300 Deerfield Beach, FL 33441 (954)421-1260 FAX: (954) 421-1466 www.ssr-inc.com Firm Certification - EB-0000857 Dennis Davie PE - 58588 John E. Moulder PE - 33200 SSR JOB # 1137001.0 W i N dR I _g _ .� a•' v 3 a U) Q N Cz _Q U) 0 co _70 _0 LL 1 0) C 70 m a� U 0 Cis U U)� CC(D w G U co cz 0 =N T Project No. 11006,00 M5. 1 02011 BHIPKArchiiecla, Inc. c N Ln L U N E 0 0 0 r` M 0 N rn E a N i W J W Z L V I C :2 EL 91 Ln C6 N X9 L SUSPEND EXHAUSTER FROM STRUCTURE WITH BAND IRON STRIPS AT EACH CORNER-7 DUCTWORK — SEE MAIN SUPPLY PLANS FOR SIZE. RETURN OR TYPICAL MANUAL EXHAUST DUCT VOLUME DAMPE PRE MANUFACTURED 450 TAKEOFF WITH GASKET FLANGE & VOLUME DAMPER ' SIMILAR TO CROWN /At 45 J m MODEL 3300—DS W , L BACKDRAFT DAMPER USE THIS WITH RECTANGULAR DUCT TAKEOFF -SMACNA 450 USE THIS WITH ENTRY FITTING: ROUND DUCT L=1/4 W. (4' MIN.) TAKEOFF'S (MAY ALSO BE PARALLEL FLOW FITTING) * = BRANCH TO INDIVIDUAL DIFFUSER OR GRILLE * * = SUBMAIN, BRANCHMAIN OR BRANCH. LOW PRESSURE DUCT VOLUME DAMPER REQUIREMENTS AHU SEQUENCE OF OPERATIONS GENERAL: Upon the detection of the products of the combustion the signal from the duct smoke detector shall cause the AHU to A shut down. The AHU shall be incapable of restart until the alarm has been cleared at the fire alarm panel. ALL INTERLOCKING SHALL BE THRU SOFTWARE CONTROL AND NOT HARD WIRING. EF Sequence of operations: Run Conditions - Interlocked: The EF shall be interlocked to the O.A. damper of the AHU to run when the damper is opened and to shutdown when the damper is closed. Fan Status: The controller shall monitor the fan status. Alarms shall be provided as follows: Fan Failure: Commanded on. but the status is off. Fan in Hand: Commanded off, but the status is on. EXHAUST FAN OCCUPIED PERIOD 30 minutes (adjustable) before the schedule start time of the occupied period of 7:00am to 6:00pm (adjustable) the system shall be indexed to operate. The supply air fan shall be energized. Upon proof of fan operation from acurrent sensor. The outside air damper shall be indexed to the full open position. Upon proof of damper position indicated by an end switch the exhaust fans shall be energized to operate. The compressors shall be modulated/staged to maintain the cooling coil leaving air temperature of 53 degrees F (adjustable). At least one compressor shall operate continuously during this period and its output be modulated to maintain the cooling coilleaving air temperature setpoint. The outside air damper shall be interlocked to the supply air fan to open when the fan is operational and close when the fan stops operating for any reason. The exhaust fans shall be interlocked to the O/A damper to operate when the dmaper is opened and to shutdown when the damper is closed for any reason. UNOCCUPIED PERIOD At the beginning of the unocuppied period of 6:00pm to 7:00am (adjustable) the O/A damper shall be closed and shall remain closed. The exhaust fan shall shut down and remain denergized. The suplly air fan and compressors shall maintain the unoccupied temperature and humidity setpoints of 80 degree F and 65% RH (adjustable). FA AIR HANDLER UNIT CEILING ASSEMBLY (SEE ARCH. DWG'S) CEILING EXHAUSTER WITH REMOVABLE EXHAUST GRILLE FOR ACCESS TO AND SERVICE OF BLOWER ASSEMBLY 21 CEILING MOUNTED EXHAUST FAN I 1 IIIf,,,, MOVI v�C,ENs ibOF ' i ,P Smith Seckman Reid, Inc. 600 West Hillsboro, Suite 300 Deerfield Beach, FL 33441 (954) 421-1260 FAX: (954) 421-1466 www.ssr-inc.com Firm Certification - EB-0000857 Dennis Davie PE - 5WM John E. Moulder PE - 33200 SSR JOB # 1137001.0 ev 1 3 tl c g i 0 a ro O O 9 A - CD E L Q 0 N W 4-1 .Q Cn O Co 0 _0 LL i 0) C _n m W 0 W _U 70 CZ 0 Se U � W =N T Project No. 11006,00 M5.2 02011 BHIPH Architects, Inc. FIRE PROTECTION LEGEND FIRE PROTECTION SPECIFICATIONS SPRINKLER NOTES C 0 CL D a i a 0 0 r- 0 N ti E O e� 2 U L C a m 0 W SYMBOL DESCRIPTION SYMBOL DESCRIPTION F FIRE LINE OR MAIN = FIRE DEPARTMENT VALVE CABINET A/S AUTOMATIC SPRINKLER MAIN FP-1, ETC FIXTURE INDENTIFICATION D DRAIN LINE CONNECTION TO EXISTING PIPE TURNED UP • FIRE EXTINGUISHER a PIPE TURNED DOWN FLOW SWITCH r BALL VALVE CAP ON LINE --� CHECK VALVE * HYDRAULIC CALCULATION PIPE NODE 1-100 UNION IN PIPE Q HYDRAULIC CALCULATION SPRINKLER D *' _ O.S.&Y. GATE OR BUTTERFLY VALVE W/TAMPER SWITCH. REMOVE EXISTING HEAD AND PLUG FITTING --�F- CHECK VALVE REMOVE EXISTING HEAD & EXTEND 1' BRANCH LINE TO NEW HEAD LOCATION CONTROL VALVE AND CHECK VALVE WITH FLOW AND TAMPER SWITCHES PIPING TO BE REMOVED i-o--o SPRINKLER HEAD BELOW DUCTWORK FIRE PROTECTION ABBREVIATIONS F.H.C. FIRE HOSE CABINET E.P. ELECTRICAL PANEL F.E. FIRE EXTINGUISHER F.E.0 FIRE EXTINGUISHER CABINET A/S AUTOMATIC SPRINKLER F.D.V.C. FIRE DEPARTMENT VALVE CABINET F.SP. FIRE STANDPIPE O.S. & Y. OUTSIDE STEM AND YOKE RCV RISER CONTROL VALVE A.F.F. ABOVE FINISHED FLOOR T.S. TAMPER SWITCH F.S. FLOW SWITCH F.D.V. FIRE DEPARTMENT VALVE A.H.J AUTHORITY HAVING JURISDICTION SPRINKLER HEAD LEGEND TYPE K-FACT TEMP LOCATION 1. CONCEALED - QRS (WHITE COVER PLATE) 5.6 1550 ALL SPACES UNLESS OTHERWISE NOTED 2. UPRIGHT GENERAL - ORS 5.6 2000 TOP OF ELEVATOR SHAFT * SEE SPECIFICATIONS FOR MODEL NUMBERS. * PLUG ALL UNUSED OUTLETS. FIRE COMPONENT SCHEDULE IDENTITY COMPONENT FP-1 FIRE EXTINGUISHER (ABC - 10 LB. - RECESSED CABINET) REGULATORY REQUIREMENTS A. NFPA 101: Life Safety Code (2006). B. NFPA 13: Standard for Sprinkler Systems (2002). C. Florida Fire Marshall's Rules 69A-3.012 F.A.C. - (2007). D. Florida Building Code - 2007 with 2009 ammendments. ALL PRODUCTS ASSOCIATED WITH THE SPRINKLER SYSTEM SHALL BE UNDERWRITERS LABORATORIES (UL) LISTED AND/OR FACTORY MUTUAL (FM) APPROVED. PIPE INTERIOR PIPE AND FITTINGS: THREADABLE THINWALL ASTM-A-795, TYPE E, GRADE A BY ALLIED 'DYNA-THREAD' (OR APPROVED EQUAL) WITH CRR=1.0, U.L. LISTED FOR THREADED PIPE ENDS, AND / OR U.L. LISTED ALLIED XL/BLT PIPE (OR APPROVED EQUAL) FOR UNTHREADED THINWALL PIPING UP TO 3. PROVIDE ABF COATING ON PIPING. FITTINGS: 1. MECHANICAL COUPLINGS: ROLL GROOVE RIGID TYPE BY VICTAULIC OR GRINNELL. 2. CLASS 125 CAST IRON SPRINKLER FITTINGS - SCREWED, FLANGED, OR GROOVED -END. 3. ALL FITTINGS SHALL BE BY THE SAME MANUFACTURER. IIIttTiT�T T� PROVIDE UL LISTED AND FM APPROVED HANGERS. ACCEPTABLE MANUFACTURERS: GRINNELL, BLINE, VIKING, FEE AND MASON. 1. GRINNELL ADJUSTABLE CLEVIS HANGER #260 MSS, TYPE 1 FOR PIPING 21/Z AND LARGER. 2. GRINNELL ADJUSTABLE SWIVEL RING HANGER *69 FOR PIPING 2' AND SMALLER. CLAMPS: 1. C-CLAMPS: GRINNELL *92 WITH RETAINER CLIP, MSS TYPE 23. 2. MALLABLE BEAM CLAMPS: GRINNELL FIGURE #218, MSS TYPE 30. EXPANSION ANCHORS: 1. HILTI-HDT-KWIK-BOLT, ZINC PLATED, METAL EXPANSION ANCHOR. ANCHOR TO MEET U.L., ICBO-4627 AND FM LISTINGS. FIRE EXTINGUISHERS AND CABINETS: ACCEPTABLE MANUFACTURERS:POTTER-ROEMER & CROKER FIRE EXTINGUISHER CABINET (ABC EXTINGUISHER) CABINET - #1704-A WHITE BAKED ENAMEL STEEL BOX WITH FULL ACRYLIC PANEL DOOR. EXTINGUISHER: # 3010, TEN POUND ABC, MULTI -PURPOSE DRY CHEMICAL. FINISH: *1961 DECAL LETERING FOR CABINET. PAINT EXTERIOR CABINET FRAME TO MATCH WALL SURFACE. SPRINKLER HEADS: ACCEPTABLE MANUFACTURERS: GRINNELL, VIKING, & RELIABLE. SPRINKLER HEADS SHALL BE U.L. LISTED AND F.M. APPROVED. CONCEALED TYPE QUICK RESPONSE SPRINKLER HEAD MAY BE U.L. LISTED ONLY. CHROME PENDENT: VIKING MICROFAST MODEL VK302, BULB TYPE, 1/� ORIFICE, PENDENT, QUICK RESPONSE, STANDARD COVERAGE, 5.6 K-FACTOR, 155 DEGREE UNLESS NOTED OTHERWISE. PIPE INSTALLATION PROVIDE HANGERS ON ALL ARM OVERS OF 12' OR MORE. SEAL PENETRATIONS OF FIRE RATED WALLS AND FLOORS IN ACCORDANCE WITH UL FIRE RESISTANCE INDEX FOR THROUGH -PENETRATION FIRESTOP SYSTEMS. COORDINATE REQUIREMENTS WITH ARCHITECT. PROVIDE TRAPEZE TYPE HANGERS WHERE NECESSARY TO SUPPORT PIPE WHEN STRUCTURAL STEEL IS NOT DIRECTLY ABOVE FOR SUPPORT. THE CONTRACTOR SHALL PROVIDE SPRINKLER SHOP DRAWINGS AND PRODUCT DATA SUBMITTALS TO ARCHITECT AND ENGINEER FOR APPROVAL PRIOR TO INSTALLATION TO CONVEY THAT HE UNDERSTANDS THE INTENT OF CONTRACT DOCUMENTS AND TO FACILITATE COORDINATION OF SPRINKLER SYSTEM WITH OTHER TRADES. THE DRAWINGS SHALL INCORPORATE ALL OF THE REQUIREMENTS OF NFPA 13. ALL MATERIAL SHALL BE DOMESTIC AND SHALL BE MANUFACTURED WITHIN THE UNITED STATES OF AMERICA. LABEL PIPING WITH SETON SNAP -ON LABELS, OR APPROVED EQUAL, TO DENOTE CONTENTS AND DIRECTION OF FLOW, AT NO MORE THAN 20 FOOT INTERVALS AND AT LEAST ONCE IN EACH SPACE THAT PIPE PASSES THRU. COLOR SHALL CONFORM TO ASME 13.1 WITH MINIMUM 2' HIGH LETTERING. ni necrni iT CONTRACTOR SHALL PROVIDE AS BUILT DRAWINGS IN AUTOCAD FORMAT AT COMPLETION OF PROJECT. I. ALL FIRE PROTECTION SYSTEM SHALL BE IN COMPLIANCE WITH THE STATE AND LOCAL FIRE CODES AND ORDINANCES AND AS PER NFPA 13 - 2002 AND NFPA 14 - 2003 EDITION REQUIREMENTS. 2. MAKE ALL OFFSETS REQUIRED AS PER JOB CONDITIONS. 3. CONTRACTOR TO PROVIDE AND TURN OVER TO THE OWNER AT LEAST (6) SPARE SPRINKLERS OF SAME TYPE AND TEMPERATURE RATING BEING INSTALLED INSIDE OF SPARE SPRINKLER CABINETS. COORDINATE LOCATION WITH OWNER. 4. CONTRACTOR SHALL FIELD VERIFY AND COORDINATE SPRINKLER HEAD LOCATIONS WITH SOFFITS AND ANY CEILING OBSTRUCTIONS PER NFPA 13. 5. ALL SPRINKLER HEADS SHALL BE CENTERED AND PRESENT A NEAT AND BALANCED CEILING PATTERN UNLESS SHOWN OTHERWISE. 6. PROVIDE AND MAINTAIN A MINIMUM CLEARANCE OF 18' BETWEEN THE BOTTOM OF THE SPRINKLER DEFLECTOR AND THE TOP OF STORAGE, FILE, SHELVING, ETC. 7. CONTRACTOR SHALL FIELD VERIFY LOCATION AND QUANTITY OF ALL CEILING MOUNTED DEVICES INCLUDING SMOKE DETECTORS TO BE REMOVED DURING CONSTRUCTION TO INSTALL SPRINKLER PIPING. EXISTING EQUIPMENT AND FIXTURES SHALL BE REPAIRED TO ORIGINAL OPERATION OR REPLACED SHOULD THEY BE DAMAGED DURING CONSTRUCTION. 8. SCHEDULE 5 PIPING AND FLEXIBLE SPRINKLER HEAD DROPS ARE NOT APPROVED OR ACCEPTED PRODUCTS. 9. CONTRACTOR SHALL COORDINATE WITH STRUCTURE AND OTHER TRADES BEFORE INSTALLING SPRINKLER WORK. 10. SPRINKLER HEAD RATED a 155 DEGREES F. t/¢ ORIFICE WITH 5.6 K-FACTOR, QUICK RESPONSE UNLESS OTHERWISE NOTEb. 11. INSTALL PIPING TIGHT TO STRUCTURE WHERE POSSIBLE. 12. SPRINKLER SYSTEM SHALL BE INSTALLED BY A STATE CERTIFIED FIRE PROTECTION CONTRACTOR. 13. SPRINKLER PIPING SHALL BE THREADABLE THINWALL ALLIED 'DYNA-THREAD' WITH CRR=1.0. U.L. LISTED AND / OR U.L. LISTED ASTM A-795 TYPE E. GRADE A ELECTRIC RESISTANCE WELDED BY ALLIED OR APPROVED EQUAL FOR PIPINb UP TO 3'. PROVIDE ABF COATING ON PIPING. 14. SYSTEM DESIGNED FOR LIGHT HAZARD OCCUPANCY, AND ORDINARY HAZARD OCCUPANCY GROUP IIN MECH AND STORAGE ROOMS. CONTRACTOR SHALL PROVIDE HYDRAULIC CALCULATIONS TO THE STREET MAIN UTILIZING A FLOW TEST TAKEN NO MORE THAN 180 DAYS BEFORE INSTALLATION IF REQUIRED BY THE LOCAL AHJ. 15. CONTRACTOR SHALL REMOVE EXISTING SPRINKLER HEADS AS SHOWN AND ADJUST PIPING TO NEW CEILING PATERN. 16. CONTRACTOR SHALL COORDINATE WITH ALL DISCIPLINES INVOLVED SO AS TO AVOID ANY PIPE ROUTING PROBLEMS. 17. EXISTING SERVICES INDICATED ON THESE DRAWINGS WERE DERIVED FROM EXISTING DRAWINGS AND LIMITED FIELD OBSERVATIONS. THESE DRAWINGS MAY NOT BE ALL INCLUSIVE OF SERVICES THAT EXIST IN THE PROJECT AREA. CONTRACTOR SHALL VERIFY SERVICES, LOCATION, TYPE AND SIZE PRIOR TO ANY CONSTRUCTION. ANY DEVIATIONS IMPACTING WORK SHOWN ON THESE DOCUMENTS SHALL BE REPORTED TO THE ARCHITECT FOR COORDINATION PRIOR TO CONSTRUCTION. 18. CONTRACTOR IS RESPONSIBLE FOR RELOCATING ALL EXISTING FIRE MAINS AND SPRINKLER PIPING TO FACILITATE THE INSTALLATION OF NEW ELECTRICAL MECHANICAL AND PLUMBING SYSTEMS. THIS INCLUDES ALL CEILING SPACES. SHAFTS. WALLS. ETC. 19. CONTRACTOR SHALL RAISE ALL EXISTING SPRINKLER PIPING WITHIN SCOPE TIGHT TO STRUCTURE AND PROVIDE NEW FITTINGS THROUGHOUT. 20. PRESSURE TEST PIPING AT 200 PSIG FOR A MINIMUM OF TWO HOURS. IF LEAKS ARE FOUND THEN CONTRACTOR SHALL FIX LEAKS AND TEST AGAIN. CONTRACTOR SHALL ALSO PROVIDE ALLOWANCE IN BID FOR PRESSURE TESTING OF EXISTING PIPING SHOWN TO REMAIN AT 200 PSIG FOR A MINIMUM OF 2 HOURS. ALLOWANCE SHALL INCLUDE FIXING LEAKS AND RETESTING. 21. FIRE PROTECTION CONTRACTOR SHALL PREPARE A SET OF INSTALLATION SHOP DRAWINGS BASED ON PIPE SIZES SHOWN COORDINATED WITH ALL THE ENGINEERING DISCIPLINES AND FIRE PROTECTION PIPING. THESE SHOP DRAWINGS SHALL BE SUBMITTED TO SSR ENGINEERS FOR APPROVAL PRIOR TO FABRICATION INSTALLATION OR SUBMITTAL TO BUILDING DEPARTMENT. ALSO, MATERIAL SUBMITTALS SHALL BE SUBMITTED FOR REVIEW AND APPROVAL PRIOR TO ANY INSTALLATION. 22. CONTRACTOR SHALL PROVIDE PROVISIONS FOR FLUSHING SPRINKLER PIPING PER NFPA 13, 8.14.16. SHOW LOCATIONS OF FLUSHING CONNECTIONS ON SPRINKLER SHOP DRAWINGS. 23. SEAL PENETRATIONS OF FIRE RATED WALLS AND FLOORS IN ACCORDANCE WITH U.L. FIRE RESISTANCE INDEX FOR THROUGH PENETRATION FIRE STOP SYSTEMS. COORDINATE REQUIREMENTS WITH ARCHITECTURAL PLANS AND SPECIFICATIONS. 24. ALL GROOVED AND SCREWED FITTING SHALL BE APPROVED BY AN ENGINEER WHO RESERVES THE RIGHT TO DISAPPROVE ANY FITTING. ALL FITTING TYPES SHALL BE FROM THE SAME MANUFACTURER. 25. VISIT THE SITE TO CHECK AND VERIFY ALL EXISTING CONDITIONS PRIOR TO BIDDING TO INSURE THE COORDINATION OF THE FIRE SERVICES WITH EXISTING CONDITIONS. 26. CUTTING OF STRUCTURAL AND/OR ARCHITECTURAL MEMBERS TO BE DONE ONLY WITH THE WRITTEN APPROVAL OF THE ARCHITECT AND STRUCTURAL ENGINEER. 27. SPRINKLER HEADS ARE TO BE COORDINATED WITH ALL CEILING DEVICES (LIGHTS, DIFFUSERS, ETC.) AND STRUCTURAL SYSTEM. 28. INDICATE CENTER TO CENTER DIMENSIONS AND/OR PIPE CUT LENGTHS AND NOMINAL PIPE DIAMETERS OF ALL PIPING ON SHOP DRAWINGS. 29. INDICATE PIPE TYPE. SCHEDULE OF WALL THICKNESS AND METHOD OF JOINING ON SHOP DRAWING. 30. PROVIDE A PERMANENTLY ATTACHED NAME TAG STATING THE REQUIRED DESIGN CRITERIA FOR EACH HYDRAULICALLY DESIGNED SYSTEM. 31. IMMEDIATELY NOTIFY THE ARCHITECT/ENGINEER OF ANY DISCREPANCIES FOUND BETWEEN THESE PLANS, OTHER ENGINEERING PLANS, THE ARCHITECTURAL PLANS AND/OR FIELD CONDITIONS PRIOR TO FINAL BID PRICE OR FINAL PERMITTING. 32. IN CASE OF DISPUTE OR DOUBT AS TO INTENT OF DRAWINGS OR SPECIFICATIONS, OBTAIN ARCHITECT/ENGINEER'S DECISION BEFORE PROCEEDING WITH WORK OR BID INVOLVED. FAILURE TO FOLLOW THIS INSTRUCTION SHALL CONSTITUTE LIABILITY FOR DAMAGE TO OTHER WORK AND FOR REMOVING AND REPAIRING DEFECTIVE OR MISLOCATED WORK IN PROPER MANNER. 33. 34. ALL SPRINKLER HEADS MOUNTED IN CEILING SHALL BE LOCATED A MINIMUM OF 4' AWAY FROM ANY WALLS, CEILING HEIGHT CHANGES OR ANY OTHER VERTICAL INTERSECTING STRUCTURAL SURFACE. 35. PIPE SHALL BE REAMED AND CLEANED BEFORE ASSEMBLY, AND AFTER ASSEMBLY. THE ENTIRE PIPING SYSTEM SHALL BE FLUSHED CLEAN. 36. ALL PENETRATIONS OR OPENINGS FROM REMOVED PIPES THROUGH EXISTING BUILDING WALLS AND FLOORS SHALL BE SLEEVED AND/OR PATCHED TO MATCH ORIGINAL. SEE ARCHITECTURAL DRAWINGS FOR FINAL FINISHES. 37. CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO EXISTING PIPING OR EQUIPMENT DUE TO NEW CONSTRUCTION AND HE SHALL RESTORE EXISTING WORK TO ITS ORIGINAL CONDITION AT NO COST TO THE OWNER. 38. PROVIDE HANGERS ON ALL ARMOVERS OF 12' OR MORE IN LENGTH AND PER NFPA 13. 39. WARRANTY/GUARANTEE A.THE CONTRACTOR SHALL WARRANTY/GUARANTEE AND MAINTAIN THE STABILITY OF WORK AND MATERIALS AND KEEP SAME IN PERFECT REPAIR AND CONDITION FOR THE PERIOD OF ONE YEAR. B. DEFECTS OF ANY KIND DUE TO FAULTY WORK OR MATERIALS, APPEARING DURING THE ABOVE MENTIONED PERIOD, MUST BE IMMEDIATELY REPAIRED BY THE CONTRACTOR AT HIS OWN EXPENSE TO THE ENTIRE SATISFACTION OF THE OWNER AND ENGINEER. SUCH RECONSTRUCTION AND REPAIRS SHALL INCLUDE DAMAGE TO THE FINISH OR FURNISHING OF THE BUILDING RESULTING FROM THE ORIGINAL DEFECT OR REPAIR THERETO. 40. PROVIDE HEAD GUARDS ON ALL SPRINKLERS IN MECHANICAL ROOMS, ELECTRICAL ROOMS AND ALL ROOMS WITH EXPOSED CEILINGS. 41. SPRINKLER HEADS SHALL BE A MINIMUM OF 12' FROM ANY DIFFUSER PER NFPA 13. 42. PROVIDE SPRINKLERS ABOVE AND BELOW DUCTWORK, CONDUIT, PIPING, ETC. 48' IN WIDTH AND LARGER. THIS INCLUDES SYSTEMS LOCATED ADJACENT TO EACH OTHER WHICH THEIR COMBINED WIDTH IS 48' OR LARGER. 43. PIPING SHALL NOT BE RUN OVER ANY ELECTRICAL AND PHONE PANELS OR EQUIPMENT. 44. THEFIRE JOBOPROGRESSES. CONTRACTOR SHALL CHANGE SHALL BE MADEATOEDFIREP PROTECTION DESIGN ENGINEERING UNLESS IT HAS BEEN COORDINATED, DRAWN AND SUBMITTED FOR APPROVAL. 45. FIRE PROTECTION SERVICES TO BE REMOVED SHALL BE CAPPED. 46. CONTINUITY OF SERVICE: INTERRUPTIONS OF EXISTING SERVICES 2. THE CONTRACTOR SHALL INCLUDE IN BID PRICE ALL PREMIUM TIME CHARGES FOR LABOR AND EQUIPMENT REQUIRED FOR ALL NIGHT AND WEEKEND OVERTIME WORK, AS NECESSARY. TO COMPLETE THE SCOPE OF THE CONTRACT. 47. SSR IS CONTRACTED BY THE HOSPITAL/OWNER TO BE THE ENGINEER OF RECORD FOR THIS PROJECT. CONTRACTOR SHALL PRODUCE SHOP DRAWINGS WHICH MATCH WHERE REQUIRED BY SITE CONDITIONS OR APPLICABLE CODES. 48. CONTRACTOR SHALL PATCH WALLS, FLOORS, ROOFING AND CEILINGS TO MATCH EXISTING FINISHES FOR DEMOLITION AND INSTALLATION OF FIRE PROTECTION SYSTEMS. COORDINATE WITH ARCHITECTURAL DRAWINGS. 49. CONTRACTOR SHALL PROVIDE ALLOWANCE IN BID FOR AN ADDITIONAL 5 CONCEALED HEADS WITH 10 FOOT 1' ARMOVER, I TEE AND 2 ELBOWS TO EACH HEAD. PROVIDE LINE ITEM COST PER HEAD WITH ASSOCIATED ARMOVER, FITTINGS AND HANGERS. INSTALL HEADS WHERE REQUIRED BY TEMPORARY WALLS, LOCAL AHJ,UNFORSEEN CONDITIONS, ETC. 50. ALL EQUIPMENT AND PIPES IN MECHANICAL ROOMS SHALL BE LABELED. PIPE LABELS SHALL INCLUDE DIRECTION OF FLOW. PAINT ALL EXPOSED FIRE MAIN AND SPRINKLER PIPING RED. 51. PROVIDE A MINIMUM OF 6 INCHES IN BETWEEN ALL PIPING AND FIRE RATED AND SMOKE TIGHT PARTITIONS FOR REQUIRED INSPECTIONS. ANY PIPING WITHIN THIS 6 INCHES SPACE SHALL BE REQUIRED TO BE MOVED AND REROUTED. ANY COST IMPACT TO OTHER TRADES WILL BE THE RESPONSIBILITY OF THE CONTRACTOR. 52. ENGINEERING SERVICES TO BE REMOVED SHALL BE CAPPED AND PLUGGED. 53. REFER TO DIVISION 15 SPECIFICATIONS FOR MORE INFORMATION. 54. CONTRACTOR SHALL PROVIDE 24/7 FIRE WATCH FOR ALL AREAS OF THE HOSPITAL THAT HAVE THE FIRE PROTECTION SYSTEM SHUTDOWN FOR 4 HOURS OR MORE AS REQUIRED PER THE FLORIDA FIRE PREVENTION CODE 2007. COORDINATE REQUIREMENTS WITH OWNER. 55. ALL MATERIAL SHALL BE DOMESTIC AND SHALL BE MANUFACTURED WITHIN THE UNITED STATES OF AMERICA. DRAWING INDEX SHEET NUMBER SHEET TITLE FPO.1 FIRE PROTECTION SPECS, LEGENDS, SCHEDULES, AND DRAWING INDEX FP1.1 FIRST FLOOR PLAN - DEMOLITION - FIRE PROTECTION FP2.1 FIRST FLOOR PLAN - NEW CONSTRUCTION - FIRE PROTECTION FP5.1 FIRE PROTECTION TYPICAL DETAILS E. MO r - w p'. T E OF : Lei % P.• # z R %�,,�G```` Smith Seckman Reid, Inc. 600 West Hillsboro, Suite 300 Deerfield Beach, FL 33441 (954) 421-1260 FAX: (954) 421-1466 www.ssr-inc.com Firm Certification - EB-0000867 Dennis Davie PE - 58588 John E. Moulder PE- 33200 SSR JOB # 1137001.0 rr' 4 O d o � E :s a v d M w o C a ' Cn x Q� L 0 N Cz Cz_+ 0 Q Cn co Cz C/) _0 0 -0 LL (D I Cn 0) C 0 m (D U U) L+_ U to a) 0 Q _U O 70 U � �--� CI) O -Ne 1` O a) �- CV LL T- Project No. 11006.00 FP0A 02011 BHIPS Architects, Inc. ..y�v - T' �(�y 'i t - - - .;a- 1. {i!f, _:- _ E• ::.. �.•' 9.i., •�,t +,rq I as •%e3 _L..y 4r - I •3�y �i�ri:'_ : ; .. ._ .,, .•�Ic�! � :...,. t��!.:�.. r,b'��l:�t�; t�. �.� _��.,..�.. 1� _ n. � ,.. � � � :• i �.'. :.:�. P:1. �� i�..�, "Es /rA1&1* w J IH L L Z LD cn W 0 Q 0 ;ctl 0 N 0 Ln J .r ....._..........-.._..__._ _ .F O O azo ................. O 0 0 FIRST FLOOR PLAN - DEMOLITION - FIRE PROTECTION LEGEND SYMBOL DESCRIPTION rDEMOLITION - - EXISTING TO REMAIN EXISTING TO BE REMOVED -- REMOVE EXISTING TO THIS POINT GENERAL NOTES: ........_...:............... ... 0 C O 0 0 0 O 1. CONTRACTOR SHALL PATCH WALLS, FLOORS, AND CEILINGS TO MATCH EXISTING FINISHES FOR DEMOLITION AND INSTALLATION OF FIRE PROTECTION SYSTEMS. COORDINATE WITH ARCHITECTURAL DRAWINGS. 2. COORDINATE SHUTDOWN OF EXISTING SYSTEMS WELL IN ADVANCE WITH OWNER. A. PERFORM WORK AT SUCH TIMES AND UNDER SUCH CONDITIONS AS PRESCRIBED BY OWNER. B. PERFORM WORK WITHIN THE GUIDELINES OF THE ICRA REPORT PREPARED FOR THIS PROJECT BY THE OWNER. C. SEQUENCE DEMOLITION AND NEW CONSTRUCTION TO MINIMIZE NUMBER & DURATION OF SHUTDOWNS REQUIRED. 3. CONTRACTOR SHALL COORDINATE WORK WITH EXISTING CONDITIONS (STRUCTURE, DUCTWORK, PIPING, CONDUIT, ETC.). PROVIDE OFFSETS AS REQUIRED TO INSTALL NEW WORK. 4. CONTRACTOR SHALL COORDINATE TIMING, DURATION AND AREAS AFFECTED BY SHUTDOWNS WITH OWNER IN ORDER TO FACILITATE REQUIRED FIRE WATCH. 5. CONTRACTOR SHALL COORDINATE NEW SPRINKLER HEAD LOCATIONS WITH CEILING GRID AND CEILING MOUNTED DEVICES (LIGHTS, DIFFUSERS, SMOKE DETECTORS, ETC.). 6. CONTRACTOR SHALL RAISE EXISTING SPRINKLER PIPING WITHIN SCOPE AND PROVIDE WITH NEW FITTINGS AND HANGERS. KEYED NOTES: O REMOVE AND REPLACE EXISTING SPRINKLER HEAD AND ASSOCIATED PIPING AND HANGERS. O REMOVE FIRE EXTINGUISHER. �� �r1 E• o!1 0. iTE OF 4/- r v'' R ,,i NALy%%,��` ERSmith Seckman Reid, Inc. 600 West Hillsboro, Suite 300 Deerfield Beach, FL 33441 (954) 421-1260 FAX: (954) 421-1466 www.ssr-inc.com Firm Certification - EB-0000857 Dennis Davie PE 58588 John E. Moulder PE - 33200 SSR JOB # 1137001.0 U U O� U o o .�' C rn ti c3 Q �1+ � O ti 0 m ro N z2t 4] U O o QQ, C3 o q b O Cl) 1 N M W O O U 70 �--� O L_L L � LL O 4-J m O O E 2— t� 0 T- 0 0 co -0 � U I O W _O �'e LL CIO -N o U) CV LL r Project No. 11006,00 FP1. 1 ©2011 BHIPK Architects, Inc. ................f,...... i GENERAL NOTES: FIRST FLOOR PLAN - NEW CONSTRUCTION - FIRE PROTECTION 111111111 1 0 - (I 1. CONTRACTOR SHALL PATCH WALLS, FLOORS, AND CEILINGS TO MATCH EXISTING FINISHES FOR DEMOLITION AND INSTALLATION OF FIRE PROTECTION SYSTEMS. COORDINATE WITH ARCHITECTURAL DRAWINGS. 2. COORDINATE SHUTDOWN OF EXISTING SYSTEMS WELL IN ADVANCE WITH OWNER. A. PERFORM WORK AT SUCH TIMES AND UNDER SUCH CONDITIONS AS PRESCRIBED BY OWNER. B. PERFORM WORK WITHIN THE GUIDELINES OF THE ICRA REPORT PREPARED FOR THIS PROJECT BY THE OWNER. C. SEQUENCE DEMOLITION AND NEW CONSTRUCTION TO MINIMIZE NUMBER & DURATION OF SHUTDOWNS REQUIRED. 3. CONTRACTOR SHALL COORDINATE WORK WITH EXISTING CONDITIONS (STRUCTURE, DUCTWORK, PIPING, CONDUIT, ETC.). PROVIDE OFFSETS AS REQUIRED TO INSTALL NEW WORK. 4. CONTRACTOR SHALL COORDINATE TIMING, DURATION AND AREAS AFFECTED BY SHUTDOWNS WITH OWNER IN ORDER TO FACILITATE REQUIRED FIRE WATCH, 5. CONTRACTOR SHALL COORDINATE NEW SPRINKLER HEAD LOCATIONS WITH CEILING GRID AND CEILING MOUNTED DEVICES (LIGHTS, DIFFUSERS, SMOKE DETECTORS, ETC.). 6. CONTRACTOR SHALL RAISE EXISTING SPRINKLER PIPING WITHIN SCOPE AND PROVIDE WITH NEW FITTINGS AND HANGERS. 7. SPRINKLER HEADS SHALL BE A MINIMUM OF 12" AWAY FROM HVAC DIFFUSERS. 8. CONTRACTOR SHALL FIELD VERIFY THAT THE EXISTING 1" SPRINKLER BRANCH PIPING DOESN'T HAVE MORE THAN 2 SPRINKLERS. IF THE 1' BRANCH LINE EXCEEDS 2 SPRINKLERS THEN A NEW V BRANCH SHALL BE RUN BACK TO THE EXISTING SPRINKLER MAINS. KEYED NOTES: OEXISTING SPRINKLER PIPING SHALL BE REWORKED AS REQUIRED TO ACCOMMODATE NEW CONSTRUCTION PLAN. EXISTING SEMI -RECESSED QUICK RESPONSE SPRINKLER HEADS SHALL BE REMOVED AND REPLACED WITH NEW QUICK RESPONSE SPRINKLER HEADS WITH 1" ARMOVER PER NFPA 13. l) O .......................................... NEW CONSTRUCTION LEGEND SYMBOL DESCRIPTION --� PIPE NEW SPRINKLER HEADS FROM EXISTING LOCATION 0 EXISTING SPRINKLER HEADS TO REMAIN EXISTING TO REMAIN NEW CONSTRUCTION —� CONNECT TO EXIST. AT THIS POINT x ATE nF Smith Seckman Reid, Inc. 600 West Hillsboro, Suite 300 Deerfield Beach, FL 33441 (954) 421-1260 FAX: (954) 421-1466 www.ssr-inc.com Firm Certification - EB-0000857 Dennis Davie PF. - 58588 John E. Moulder PE - 33200 SSR JOB # 1137001.0 k2 CID �o o N � —Qd ty c�D 6 T_- 0 ti d o q L N O a . �--� Q. U � i O O = a- M (D l 1__ _O � I O 4--1 � L � Cn O m U (a) LF— (a) ' z 0 I (� _U CIO L O (J7 O "e IL (13 N O U_ CV T Project No, 11006.00 FP2.1 D2011 UHIPK Archiiects, Inc. c / E _7 Q a rn / Ln _O O Ln 00 �J[J ZI L7 """ DIMENSION. MINIMUM DIA. INSTALL THREADED ROI DOWN TO TOP OF PIPE "B" (INCHES) ADJUSTIBLE CLEVIS HANGER FOR PIPING 4" AND LARGER GRINNELL FIG #260 SIDE JOIST ATTACHMENT OR SIDE JOIST ADJUSTABLE HANGER HHAN ER ROD DIAMETER IS THE MINIMUM SIZE PER NFPA. HANGER ROD DIAMETER SHALL BE THE DIAMETER APPROVED FOR USE WITH THE HANGER ASSEMBLY. 'A" DIMENSION. [MUM DIA. PHILLIPS CONCRETE , FASTENER I.T.T. GRINNELL (RED HEAD) TO BE USED ON NEW CONSTRUCTION. PROVIDE HILTIKWIK BOLT, ZINC PLATED. METAL EXPANSION ANCHOR ON EXISTING CONSTRUCTION (SEE SPECIFICATIONS). ADJUSTIBLE SWIVEL RING HANGER FOR PIPING 3" AND SMALLER GRINNELL FIG #69 CENTER I -BEAM CLAMP HANGERS HANGER SPACING 1. 1" AND 11,4 DIA. STEEL PIPE: MAXIMUM 12 FT. SPACING. 2. 1",�HRU 3" DIA. THREADED LIGHTWALL PIPE: MAX. 12 FT. SPACING 3. 11,12 AND LARGER DIA. STEEL PIPE: MAXIMUM 15 FT. SPACING. 4. ALL PIPING SHALL BE SUPPORTED IN ACCORDANCE WITH NFPA-13. EACH SECTION OF PIPE SHALL HAVE NO LESS THAN ONE HANGER. ARMOVERS EXCEEDING 1 FT. SHALL HAVE A HANGER. 5. PROVIDE PIPE CLAMP AT EACH FLOOR FOR RISERS PENETRATING FLOORS. 6. ALL HANGERS. THREADED ROD, NUTS, BOLTS. CLAMPS ETC. SHALL BE GALVANIZED. PIPE HANGER DETAIL „AIN A/S DRAIN INE FLOOR TO FLOOR ISER CLAMP IS ZONE DRAIN LINE (SEE PLANS) /S DRAIN VALVE JSPECTOR TEST ONNNECTION TEST VALVE V ITE GLASS 1' RUST BE VISIBLE) INION WITH ORIFICE ;ONNECTION TO MAIN ,/S DRAIN LINE ISER CLAMP IPPER FLOOR NOTE: SINGLE A/S ZONE PIPE ARRANGEMENT WITH A CONTINUOUS MAIN A/S ELEVATION DRAIN LINE FLOOR TO FLOOR AND EXPOSED PIPES. EXISTING A\S DRAIN AND TEST CONNECTION DETAIL "A" DIMENSION. MINIMUN DIA.(INCHES) THREADED ROD SIZE. CUT TO LENGTH SELF DRILLING CONCRETE WEDGE ANCHOR TOP BEAM CLAMP A B PIPE SIZE A B hP 3/8 1/8 4 3/ 1/4/8 / 6 1/ 1/4 3/8 1/8 8 1/ 1/4 2 1/4 10 5/8 1/4 2 1/4 12 1/4 /4 HANGER ROD SCHEDULE N.T. S MINIMUM ONE HANGER ON ARMOVERS 12' OR MORE IN LENGTH V DROP NIPPLE 1' X 1 /2' REDUCER CONCEALED SPRINKLER HEAD TYPICAL SPRINKLER HEAD DROP (RETURN BEND) DETAIL 1' CLOSE NIPPLE BRANCH LINE CEILING N.T.S. FP-1 4'-0' FIN.FL. FIRE EXTINGUISHER IN RECESSED CABINET FIRE EQUIPMENT MOUNTING HEIGHT FLOOR CONTROL VALVE WITH TAMPER SWITCH ELECTRIC WATER FLOW SWITCH PRESSURE GAUGE & COCKS n STANDPIPE OR SPRINKLER MAIN. SEE FLOOR PLAN FOR SIZES.— TO AUTOMATIC SPRINKLER SYSTEM. SEE FLOOR PLAN FOR CONTINUATION. EXISTING A\S ZONE CONNECTION DETAIL N.T.S. Smith Seckman Reid, Inc. 600 West Hillsboro, Suite 300 Deerfield Beach, FL 33441 (954)421-1260 FAX: (954) 421-1466 www.ssr-inc.com Firm Certification - EB-0000857 Dennis Davie PE- 58588 John E. Moulder PE- 33200 SSR JOB # 1137001.0 v c.� �4 Q � ti 9? g Izz �g R 2 a o� a ro ~ U y O 0 U) iE L 0- N Q U) 0 CCS _0 LL 1 0) 70 .5 In a) C13 y-�- -� 0 0 (5 _0 0 -o U 0 0 0 L O 0 >` CV L T Project No. 11006.00 FP5.1 02011 BHIPK Architects, Inc. U) W IN ABBREVIATIONS LEGEND 0 N 0 N, Ln w 1 Z C� rti t0 W 314C. MIN. TYPICAL EXISTING EXISTING FACP NAC S REFER TO FLOOR PLANS FOR QUANTITY OF DEVICES FIRST FLOOR FIRE ALARM RISER DIAGRAM NO SCALE FIRE ALARM SYSTEM NOTES: A. CONTRACTOR SHALL REFER TO SPECIFICATIONS. B. CONTRACTOR SHALL BE RESPONSIBLE FOR FURNISHING VENDOR SHOP DRAWINGS INDICATING ALL MODEL NUMBERS, WIRING REQUIREMENTS AND BATTERY CALCULATIONS. SHOP DRAWINGS SHALL BE SIGNED AND SEALED BY FLORIDA REGISTERED ENGINEER. C. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR ALL SYSTEMS EQUIPMENT AND CABLE AND ALL INSTALLATIONS. D. REFER TO FIRE ALARM MANUFACTURERS' RECOMMENDATIONS FOR CONDUIT AND CONDUCTOR SIZE AND TYPES. REFER TO SPECIFICATIONS. E. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL HARDWARE AND SOFTWARE TO SUPPORT EXTENSION OF FIRE ALARM SYSTEM. F. VISUAL DEVICES TO BE IN SYNC WITH EACH OTHER AND AUDIBLE DEVICES TO BE IN SYNC WITH EACH OTHER. G. AUDIBLE AND VISUAL DEVICES TO BE ON DIFFERENT CIRCUITS. H. STROBES TO BE 75 CANDELA EVERYWHERE. I. VOLTAGE DROP AND BATTERY LOAD CALCULATIONS TO BE PROVIDED AND VERIFIED AT SUBMITTAL PROCESS. J. FIRE ALARM SYSTEM SHALL BE NETWORKED WITH EXISTING SYSTEM. K. FURNISH TVSS PER SPECIFICATIONS ON ALL COPPER CABLING ENTERING THE BUILDING. L. THE CONTRACTOR SHALL PROVIDE CONNECTION TO THE OWNERS EXISTING FIRE ALARM SYSTEM. PROVIDE ALL NECESSARY SYSTEM CABINETS, POWER SUPPLIES, MICRO -CONTROLLERS, KEYBOARD DISPLAYS, LED DISPLAYS, BATTERIES, PERIPHERAL DEVICES, VOICE EVACUATION SYSTEMS, ETC. FOR A COMPLETE AND FUNCTIONING SYSTEM. FI RE ALARM SYSTEM COMPONENTS SHALL MATCH EXISTING. M. THE SYSTEM SHALL COMPLY WITH ALL CURRENT, APPLICABLE CODES INCLUDING THE FOLLOWING: 1. NATIONAL ELECTRICAL CODE ( NEC) 2. NATIONAL FIRE PROTECTION AGENCY A. NFPA 72 B. NFPA 101 LIFE SAFETY CODE 3. ALL APPLICABLE UL STANDARDS 4. AMERICANS WITH DISABILITIES ACT (ADA) 5. LOCAL CODE REQUIREMENTS N. CONTROL PANEL 1. THE CONTRACTOR SHALL PROVIDE ALL NECESSARY HARDWARE AND SOFTWARE PROGRAMMING NECESSARY TO ACCOMMODATE MODIFICATIONS INDICATED ON DRAWINGS. 0. THE CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING THE EXISTING FIRE ALARM PROTECTION UNTIL NEW DEVICES HAVE BEEN PROPERLY CERTIFIED AND APPROVED BY THE AUTHORITY HAVING JURISDICTION. ALL EXISTING WIRING, BOXES, CONDUITS SERVING THE DEVICES TO BE REMOVED SHALL BE DEMOLISHED. ALL INACTIVE WIRING SHALL BE LABELLED 'ABANDONED. DO NOT USE.' P. THE CONTRACTOR SHALL PROVIDE A RECORD OF COMPLETION FOR THE FIRE ALARM SYSTEM AND A SENSITIVITY REPORT FOR ALL SMOKE AND DUCT DETECTORS INSTALLED IN THE PROJECT AREA. 0. COORDINATE THE SHUTDOWN OF AIR HANDLER UNITS, EXHAUST FANS, ETC WITHIN THE PROJECT AREA WITH DIVISION 15. SEAL PENETRATIAKIC cn AC TO MAINTAIN R WALL FOR FIRE FIRE RATED WALL CONDUIT ENDS SO AS ITING OF WALL FOR FIRE PROOFING. NOTE REFER TO ARCHITECTURAL DRAWINGS FOR UL ASSEMBLY NUMBERS AND WALL RATINGS. RATED WALL PENETRATIONS STRUCTURE ABOVE MINIMUM THREE TWI *12 GAUGE GALVAN WIRE HANGER (TYPII TYPICAL FIXTURE FIXTURE SUPPRORT NOTES: ATTACH CADDY ANGLE BRACKETS (TYPICAL) ATTACH CADDY ANGLE BRACKET WITH #18 SELF -TAPPING SHEET - METAL SCREWS INIMUM 15% OFF VERTICAL 3TH DIRECTIONS 1. ATTACH ALL LIGHT FIXTURES TO THE CEILING GRID RUNNERS TO RESIST A HORIZONTAL FORCE EQUAL TO THE WEIGHT OF THE FIXTURES. 2. ALL FLUSH OR RECESSED LIGHT FIXTURES -ROUNB5 SHALL BE SUPPORTED DIRECTLY ON THE RUNNERS OF A HEAVY DUTY GRID SYSTEM AND THEY MUST HAVE A MINIMUM OF TWO #12 GAUGE SLACK SAFETY WIRES ATTACHED AT DIAGONAL CORNERS AND ANCHORED TO THE STRUCTURE ABOVE. 3. ALL FIXTURES SUPPORTED ON INTERMEDIATE DUTY GRID SYSTEMS MUST BE INDEPENDENTLY SUPPORTED BY NOT LESS THAN FOUR TAUT *12 GAUGE WIRES ATTACHED TO THE STRUCTURE ABOVE. 4. ALL FLUSH OR RECESSED LIGHT FIXTURES WEIGHING MORE THAN 56 POUNDS MUST BE INDEPENDENTLY SUPPORTED BY NOT LESS THAN FOUR *12 GAUGE TAUT WIRES ATTACHED TO THE STRUCTURE ABOVE REGARDLESS OF THE TYPE OF CEILING GRID SYSTEM USED. 5. THE FOUR TAUT *12 GAUGE WIRES INCLUDING THEIR ATTACHMENT TO THE STRUCTURE ABOVE MUST BE CAPABLE OF SUPPORTING FOUR TIMES THE WEIGHT OF THE UNIT. LIGHT FIXTURE SUPPORT DETAIL SYMBOL DESCRIPTION ABC ABOVE COUNTER ACLG ABOVE FINISHED CEILING AFF ABOVE FINISHED FLOOR AFG ABOVE FINISHED GRADE BKR BREAKER CB CIRCUIT BREAKER CKT CIRCUIT CL CENTER LINE CLG CEILING MOUNTED DEVICE DISC DISCONNECT DIV DIVISION ECB ENCLOSED CIRCUIT BREAKER EX EXISTING EXR EXISTING, RELOCATED F FRAME F/A FIRE ALARM FCU FAN COIL UNIT FLA FULL LOAD AMPS FU FUSE G GROUND HP HORSE POWER K KILO MCB MAIN CIRCUIT BREAKER MLO MAIN LUGS ONLY NCT NURSE CALL TERMINAL CABINET NEC NATIONAL ELECTRIC CODE NIC NOT IN CONTRACT NL NIGHT LIGHT OC OVER CURRENT OCP OVER CURRENT PROTECTION P POLE PH PHASE SMH SPECIAL MOUNTING HEIGHT TV TELEVISION TYP TYPICAL UH UNIT HEATER UG UNDER GROUND ELECTRICAL UON UNLESS OTHERWISE NOTED UON UNINTERRUPTIBLE POWER SUPPLY V VOLT(S) VA VOLT -AMPS) W WATT(S), WIRE, WALL TELEPHONE OUTLET WP WEATHERPROOF DEVICE, NEMA 3R XFMR TRANSFORMER SYMBOL DESCRIPTION MOUNTING HEIGHT LIGHTING ®NORMAL BRANCH SURFACE OR RECESSED FLUORESCENT FIXTURE (TYPE DETERMINES MOUNTING) NORMAL BRANCH SURFACE OR RECESSED FIXTURE (TYPE DETERMINES MOUNTING) ®+ EXIT LIGHT, PROVIDE DIRECTIONAL ARROWS AS INDICATED ON PLANS POWER - RECEPTACLES 120V. DUPLEX RECEPTACLE - IVORY (REFER TO RECEPTACLE 1'-6' ABBREVIATIONS FOR EXCEPTIONS) AFF TO CL 120V. DUPLEX RECEPTACLE - IVORY - SPECIAL MOUNTING HEIGHT AS NOTED OR (REFER TO RECEPTACLE ABBREVIATIONS FOR EXCEPTIONS) SEE SPECS 120V. QUADPLEX RECEPTACLE - IVORY (REFER TO RECEPTACLE 1'-6' ABBREVIATIONS FOR EXCEPTIONS) AFF TO CL 120V. QUADPLEX RECEPTACLE - IVORY - SPECIAL MOUNTING HEIGHT AS NOTED OR (REFER TO RECEPTACLE ABBREVIATIONS FOR EXCEPTIONS) SEE SPECS �- 120V. GFI RECEPTACLE (SPECIAL MOUNTING HEIGHT) AS NOTED OR SEE SPECS SWITCHES S SINGLE POLE SWITCH - IVORY TOGGLE 3'-10' AFF TO CL S3 THREE WAY SWITCH - IVORY TOGGLE 3'-10' AFF TO CL SM WALL VOLTAGE, LINE ,DUAL TECH OCCUPANCY SENSOR '' COOPER GREENGATE ONW D AFFTO CL os LINE VOLTAGE OCCUPANCY SENSOR - CEILING COOPER GREENGATE #DT-2000 LOW VOLTAGE OCCUPANCY SENSOR - CEILING COOPER GREENGATE #ODC-U-2000 ®L SWITCHPACK - COOPER GREENGATE #SP20 FIRE ALARM FIRE ALARM VISUAL STATION - LIGHT ONLY FIRE ALARM MANUAL PULL STATION 3'-10' AFF TO CL FD FIRE ALARM CHIME WITH LIGHT 0 FIRE ALARM SMOKE DETECTOR CEILING FRCP FIRE ALARM CONTROL PANEL ® FIRE ALARM RELAY TELEPHONE/DATA �- TELEPHONE OUTLET WITH PLATE (SPECIAL MOUNTING HEIGHT) AS NOTED SEE SPECS. COMBINATION DATA/TELEPHONE OUTLET WITH PLATE 1'-6' AFF TO CL COMBINATION DATA/TELEPHONE OUTLET WITH PLATE AS NOTED (SPECIAL MOUNTING HEIGHT) SEE SPECS. MISCELLANEOUS q= NON -FUSIBLE SAFETY SWITCH, SIZE AS NOTED (AMP RATING/POLES) FUSIBLE SAFETY SWITCH, SIZE AS NOTED (AMP RATING/POLES) s PANELBOARD - FLUSH MOUNTED PANELBOARD - SURFACE MOUNTED WIRING CONCEALED CONDUIT CONDUIT CONCEALED IN FLOOR OR BELOW GRADE HOMERUN TO PANELBOARD - NUMBER OF PHASE CONDUCTORS IN MINIMUM 314 CONDUIT UNLESS NOTED OTHERWISE NOTES: I. ONE NEUTRAL CONDUCTOR FOR EACH PHASE CONDUCTOR, ALTHOUGH NOT INDICATED, SHALL BE INCLUDED IN EACH RACEWAY UNLESS OTHERWISE NOTED. 2. ONE INSULATED GREEN GROUNDING CONDUCTOR, ALTHOUGH NOT INDICATED, SHALL BE INCLUDED IN EACH RACEWAY UNLESS OTHERWISE NOTED. 3. HOMERUNS TO PANELBOARDS SHALL HAVE A MAXIMUM OF THREE (3) PHASE CONDUCTORS (ONE PER PHASE)PLUS THREE (3)NEUTRAL CONDUCTORS AND ONE (1) GROUND CONDUCTOR IN EACH CONDUIT. 4. MULTI -WIRE BRANCH CIRCUITS THAT SHARE A COMMON NEUTRAL SHALL NOT BE PERMITTED FOR INDIVIDUAL LINE -TO -NEUTRAL LOADS. 5. EACH CIRCUIT (PHASE AND NEUTRAL CONDUCTORS) SHALL BE GROUPED TOGETHER USING CABLE TIES AT THE PANELBOARD AND ALL JUNCTION BOXES, PULL BOXES AND ALL OTHER LOCATIONS WHERE TERMINATIONS, CONNECTIONS OR SPLICES ARE MADE. 6. ALL CONDUCTORS SHALL BE *12 AWG UNLESS OTHERWISE NOTED. ALL WORK SHALL COMPLY WITH THE 2008 EDITION OF THE NEC. DRAWING INDEX SHEET NUMBER SHEET TITLE EO.1 ELECTRICAL LEGENDS, SCHEDULES, AND DRAWING INDEX E1.1 FIRST FLOOR PLAN - DEMOLITION - ELECTRICAL E2.1 FIRST FLOOR PLAN - NEW CONSTRUCTION - LIGHTING E3.1 FIRST FLOOR PLAN - NEW CONSTRUCTION - POWER & SYSTEMS E4.1 ELECTRICAL RISER DIAGRAMS E5.1 ELECTRICAL SPECIFICATIONS Smith Seckman Reid, Inc. 600 West Hillsboro, Suite 300 Deerfield Beach, FL 33441 (954) 421-1260 FAX: (954) 421-1466 www.ssr-inc.com Firm Certification - EB-0000867 Dennis Davie PE - 58588 John E. Moulder PE - 33200 SSR JOB # 1137001.0 v �o el. 4 o o � -2. x (1) 70 0 • • U) _0 70 (D U U) N NON (Z U U _0 Lll T i Q, N W 07 0 C� _70 _0 L_L_ 0) C 70 .:3 In 0 U 4- 4-- O C� U_ 0 U) W O CV T Project No. 11006.00 EO. 1 02011 BHINArchitects, Inc. V I i r , +r a, �, _ �.y�p}. � y ( "{{ 'fl1 1 p V •. �- ..-11- .1 ..;: ..:: .. ♦ '-If •' '.�' � .. �. _ iit �� '� � �V'... I.�.: C�-7.. �. � 1 � ^,cn. r I �, � 1.. 't I' � .r � I) r � ..I. �� �. '■ r� � i� �� r... iT.... .. ♦.i- '� 'lil-. i `r 111 .1i. `lh ., .M,�' +q i LIMIT OF DEMOLITION' vrrvL Mur ...... F: t.....-.:_.. ' I 225KVA O EY XFMR 1 !� i is O1 PNL 'HMDP' 1. i FIRST FLOOR PLAN - DEMOLITION - ELECTRICAL DEMOLITION LEGEND L f DESCRIPTION EXISTING TO REMAIN EXISTING TO BE REMOVED C w I � a O / N O_ v O M O O �CDJ 0 N rM E o N � O / Ln wO J J n- CL Z O W Cn O O GENERAL DEMOLITION NOTES IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO REMOVE EXISTING EQUIPMENT AS REQUIRED TO ACCOMPLISH THE NEW WORK AS SHOWN OR REASONABLY IMPLIED. THE CONTRACTOR SHALL REFER TO THE NEW ARCHITECTURAL PLUMBING, FIRE PROTECTI ON, MECHANICAL AND ELECTRICAL WORK SHOWN ON THE OTHER DRAWINGS OF THIS SET TO DETERMINE THE EXTENT OF DEMOLITION REQUIRED. WHEN REMOVING ELECTRICAL EQUIPMENT AND SYSTEMS!,. ALL PRECAUTIONS SHALL BE TAKEN TO PREVENT STRUCTURAL DAMAGE TO THE BUILDING. IHE CONTRACTOR SHALL COORDINATE INSTALLATION OF ANY STRUCTURAL SUPPORTS REQUIRED, TEMPORARY OR PERMANENT. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REMOVAL OF ALL DEMOLITION AND CONSTRUCTION DEBRIS GENERATED FROM WORK ON ALL FLOORS. TAKING CARE TO PREVENT EXCESSIVE LOADING OF FLOOR ASSEMBLIES. THE CONTRACTOR SHALL MAINTAIN CONTINUITY OF CIRCUITS WHERE EXISTING EQUIPMENT IS TO BE REMOVED AND DOWN STREAM DEVICES MAY BE EFFECTED. THE CONTRACTOR SHALL COORDINATE ALL POWER INTERRUPTIONS WITH OWNER. SEE SPECIFICATIONS. WHEN EXISTING ELEMENTS OF ELECTRICAL EQUIPMENT AND SYSTEMS ARE REMOVED ALL REMAINING OPENINGS IN THE SLAB AND WALLS SHALL BE FILLED IN BY THE CONTRACTOR. THE FIRE RATING OF THE EXI STI NG STRUCTURE SHALL BE MAINTAINED. REMOVE ALL MISCELLANEOUS FIXTURES AND EQUIPMENT RETAINING ITEMS TO BE IDENTIFIED FOR SALVAGE AND STORAGE AT THE DIRECTION OF THE OWNER. THE CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS DURING DEMOLITION AND CONSTRUCTION TO MAINTAIN THE INTEGRITY AND OPERATION OF EXISTING LIFE SAFETY AND EMERGENCY EGRESS EQUIPMENT. THE CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS DURING DEMOLITION AND CONSTRUCTION TO MAINTAIN ACCESS TO ALL MEANS OF EGRESS CORRIDORS, DOORWAYS AND STAIRS. THE CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS DURING DEMOLITION AND CONSTRUCTION TO PERMIT EFFECTED AREAS TO CONTINUE TO FUNCTION TO THE GREATEST EXTENT POSSIBLE. THIS EFFORT SHALL INCLUDE SCHEDULED COORDINATION WITH OWNER OF ELECTRICAL SHUTDOWNS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REMOVAL OF ALL FLUORESCENT AND HID TYPE LAMPS AND PROPER DISPOSAL OF SAID LAMPS AND SHALL PROVIDE VERIFICATION OF LAMP DISPOSAL TO THE OWNER UPON REQUEST. REMOVE ALL LIGHTING FIXTURES, RECEPTACLES AND DEVICES IN THE AREA OF DEMOLITION AND PULL ALL CIRCUITS BACK TO NEXT ACTIVE DEVICE OR SOURCE OF POWER. ALL CONDUIT, JUNCTION BOXES AND WIRING DEVICES THAT ARE NOT INTENDED TO RE —USED MUST BE DEMOLISHED BACK TO THE SOURCE. PROVIDE PANEL SCHEDULES, TO THE ENGINEER, INDICATING THE CIRCUITS MADE SPARE BY DEMOLITION AND THE EXISTING CIRCUITS THAT REMAIN ACTIVE. IT SHALL BE THE RESPONSIBILITY OF THE CONSTRUCTION MANAGER (CM) , GENERAL CONTRACTOR ( GC) , AND THE SUB —CONTRACTORS (SC) TO STUDY ALL THE DRAWINGS AND DETAILS SO THAT THE INSTALLATION OF ALL NEW WORK CAN BE FULLY COORDINATED. THE CM, GC, AND SC SHALL VISIT THE SITE, INCLUDING DOING AN ABOVE CEILING INSPECTION, DURING BIDDING TO SATISFY HIM/HER SELF THAT ALL PROVISIONS HAVE BEEN MADE FOR ALL ASPECTS OF THIS PROJECT. IF DISCREPANCIES EXIST BETWEEN DRAWINGS AND/OR SITE CONDITIONS, THE CONTRACTOR SHALL NOTIFY THE GENERAL CONTRACTOR IN WRITING PRIOR TO BID DUE DATE. FAILURE TO DO SO WILL NOT BE ALLOWED ON A BASIS FOR ADDITIONAL COMPENSATION TO CORRECT A DIFFICULTY OF DIFFERENCE FROM CONDITIONS INFERRED OR INDICATED ON THE DRAWI NGS. DRAWINGS ARE DIAGRAMMATIC AND DO NOT INDICATE ALL DEVICES TO BE DEMOLISHED. CONTRACTOR SHALL VISIT JOB SITE PRIOR TO BID TO FIELD CONFIRM ALL REQUIREMENTS. GENERAL NOTES: A. UNLESS OTHERWISE NOTED, ALL RECEPTACLES, LIGHTING AND DATA DEVICES WITHIN SCOPE OF WORK AREA SHALL BE REMOVED. REMOVE ALL WIRES BACK TO SOURCE. WHERE APPLICABLE, CONTRACTOR SHALL RE —USE EXISTING RACEWAY FOR NEW WORK. REFER TO NEW WORK ON SHEET E2.1 AND E3.1. B. COORDINATE EXTENT OF DEMOLITION WITH ALL TRADES. KEYED NOTES: 0 EXISTING TO REMAIN. O2 UNLESS OTHERWISE NOTED, POWER, LIGHTING AND SYSTEMS SHALL BE EXISTING TO REMAIN. RECIRCUIT EXISTING LIGHTING AS PER NEW WORK SHEET E2.1. RECIRCUIT EXISTING RECEPTACLE AS PER NEW WORK SHEET E3.1. 0 EXISTING ELECTRIC DUCT HEATER TO BE RELOCATED. MAINTAIN EXISTING DISCONNECT SWITCH AND BRANCH CIRCUIT FOR NEW WORK. CONTRACTOR SHALL FIELD VERIFY BRANCH CIRCUIT NUMBER. REFER TO NEW WORK SHEET E3.1. 0 EXISTING AIR HANDLING UNIT AND ASSOCIATED DISCONNECT SWITCH AND RELAYS SHALL BE EXISTING TO REMAIN. Smith Seckman Reid, Inc. 600 West Hillsboro, Suite 300 Deerfield Beach, FL 33441 (954) 421-1260 FAX: (954) 421-1466 www.ssr-inc.com Firm Certification - EB-0000857 Dennis Davie PE - 58588 John E. Moulder PE - 33200 SSR JOB # 1137001.0 —J r TE OF ; v "4/10NA�0���`�. ci cry •� 4 p R •—. g GCS �1 i� z2 a _gyp re i� M ''N �r' � o 2 A a� o y LO C 9 L O W, L Q N Cz U) O _ Cz _0 _O LL Project No. 110M.00 El .1 1 02011 BNIPH Architects, Inc. a LD .J D-25.27.29 FIRST FLOOR PLAN - NEW CONSTRUCTION - LIGHTING I�I�I I0� (1) LIGHTING FIXTURE SCHEDULE TYPE MANUFACTURER CATALOG NO. LAMPS VOLTS MOUNTING REMARKS F1 DAYBRITE 2DPG332-FA12-UNV- 1 /3EB10R 3-F32T8 UNV RECESSED 2'X 4' LENSED FLUORESCENT FIE DAYBRITE 2DPG332-FA12-UNV- 1/3EB10R-E5 3-F32T8 UNV RECESSED 2' X 4' LENSED FLUORESCENT WITH BATTERY PACK F2 OMEGA S61H260PLU-T61HCS 1-26W QPL 120 RECESSED 6' DOWNLIGHT F3 DAYBRITE 2DPG432-FA12-UNV- 1 /4EB10R 4-F32T8 UNV RECESSED 2'X 4'LENSED FLUORESCENT m ® BEGHELLI VA4-R-SA LED UNV UNIVERSAL EXIT SIGN WITH BATTERY GENERAL LIGHTING FIXTURE NOTES: 1. CONTRACTOR MUST QUOTE SPECIFIED LIGHTING FIXTURES AS BASE BID. ANY ALTERNATE LIGHTING PRODUCTS MUST BE SHOWN AS AN EXCEPTION TO BASE BID. AND MUST BE ACCOMPANIED BY UNIT PRICES AND TOTAL DOLLAR DEDUCT FROM THE BASE BID. 2. ANY PROPOSED ALTERNATES SHALL MATCH SPECIFIED LIGHTING FIXTURE CHARACTERISTICS AS FOLLOWS: a. ALL RATINGS INCLUDING, BUT NOT LIMITED TO, WATTAGE, FIRE RATINGS, AND SPECIAL LOCATION RATINGS SUCH AS DAMP OR WET LABELS, HAZARDOUS LOCATION, CLEAN ROOM, TAMPER PROOF. ETC. b. PHYSICAL SIZE AND DIMENSION c. CONSTRUCTION cl. MATERIAL e. LAMP AND BALLAST TYPE f. LENS AND REFLECTOR TYPE g. PAINT APPLICATION PROCESS h. PHOTOMETRIC CHARACTERISTICS 3. PROVIDE DIMMABLE BALLAST FOR ANY FIXTURE SHOWN BEING CONTROLLED WITH A DIMMER SWITCH. 4. PROVIDE SINGLE OR DOUBLE FACE EXIT SIGNS AS SHOWN ON PLANS BY SHADED FACE. PROVIDE DIRECTIONAL ARROWS WHERE SHOWN ON PLANS. GENERAL NOTES: A. REFER TO SHEET E3.1 FOR LOCATION OF ELECTRICAL PANELS. KEYED NOTES: lU EXIT SIGN SHALL BE CIRCUITED AHEAD OF SWITCHING LEG. (TYPICAL FOR ALL) 0 CORRIDOR LIGHT FIXTURES WITH BATTERY PACK SHALL BE CIRCUITED AHEAD OF SWITCHING LEG. (TYPICAL FOR ALL) RECIRCUIT EXISTING LIGHT FIXTURE TO NEW BRANCH CIRCUIT AS SHOWN. CONNECT TO AVAILABLE SPARE CIRCUIT BREAKER IN PNL 'B.' 5O CIRCUIT LIGHT FIXTURE TO EXISITNG SWITCH AND BRANCH CIRCUIT SERVING THE BREAKROOM; FIELD VERIFY EXISTING CIRCUIT NUMBER. NEW CONSTRUCTION LEGEND SYMBOL --- DESCRIPTION EXISTING TO REMAIN NEW CONSTRUCTION Smith Seckman Reid, Inc. 600 West Hillsboro, Suite 300 Deerfield Beach, FL 33441 (954)421-1260 FAX: (954) 421-1466 www.ssr-inc.com Firm Certification - EB-0000857 Dennis Davie PE - 68588 John E. Moulder PE • 83200 SSR JOB # 1137001.0 4 • 1+.1 ^w► �6V �7+ �k O N �j Cp JI R :t g I a� q s e 4 V i Q- N U) 0) 0 co J _O � I O U � D -- L— -0 4 -+ —_ _ co O 00 U a) 4— z O 1 (� -U (0 70 �c � c O Cn _O -�e LL (13 -m o L CV ILL T Project No.11006,00 E2. 1 02011 BHIPH Architects, Inc. 11 18.20 W* W W D-23 D-18,20,22 PNL 'D' OO OO D-17,19,21 FIRST FLOOR PLAN - NEW CONSTRUCTION - POWER & SYSTEMS N 0' 2' 4' 8' 16' 24' GENERAL NOTES; A. COORDINATE EXACT LOCATION AND MOUINTING HEIGHT OF ALL RECEPTACLES AND DATA OUTLETS WITH ARCHITECT AND OWNER'S REPRESENTATIVE PRIOR TO ROUG IN. KEYED NOTES; O CONNECT TO AVAILABLE SPARE CIRCUIT BREAKER IN PNL 'B.' O RECIRCUIT EXISTING RECEPTACLE TO NEW BRANCH CIRCUIT AS SHOWN. O3 NEW LOCATION OF EXISTING ELECTRIC DUCT HEATER. FIELD COORDINATE EXACT LOCATION WITH MECHANICAL CONTRACTOR. EXTEND EXISTING BRANCH CIRCUIT TO NEW LOCATION AS REQUIRED. FIELD VERIFY EXISTING BRANCH CIRCUIT NUMBER. 0 EXISTING TO REMAIN. FIELD VERIFY EXISTING CIRCUIT NUMBER. O FUSE PER MANUFACTURER'S NAMEPLATE REQUIREMENTS. O6 COORDINATE EXACT LOCATION WITH MECHANICAL. PROVIDE CLEARANCES AS REQUIRED. EXHAUST FAN SHALL BE INTERLOACKED WITH AIR HANDLER CONTROLS; PROVIDE AND INSTALL RELAY/CONTACTOR AS REQUIRED. REFER TO MECHANICAL DRAWINGS FOR ADDITIONAL INFORMATION. O COORDINATE EXACT LOCATION WITH PLUMBING. PROVIDE CLEARANCES AS REQUIRED. O8 EXISTING TO REMAIN. FIELD VERIFY EXACT LOCATION. A-23,25,27 AHU-1O A-26,28,30 CU-lO4 R n LEGEND L ffCONSTRUCTION DESCRIPTION EXISTING TO REMAIN NEW CONSTRUCTION Smith Seckman Reid, Inc. 600 West Hillsboro, Suite 300 Deerfield Beach, FL 33441 (954)421-1260 FAX: (954) 421-1466 www.ssr-inc.com Firm Certification - EB-0000857 Dennis Davie PF - 58588 John E. Moulder PE - 33200 SSR JOB # 1137001.0 0 • �q ��ii \�•. \G E N S �6F , �F <pR �yC9 /� 'S '�•,� ��\1,,,'Cy `fir A,- v o� v o d� ' ti N zzt N w a q d 0 CD CD E j N Cf) _ CIO U) a--' Q O O (Tj -_ O % C _O H O IL C :3 O m U CD (u z 0 -U (10 70 CU O Cf) O -'z LL (15 N o (n I CV Li- T- Project No. 11006.00 E3. 1 02011 BUK Architects, Inc. 'A11:I�I fwI mm zU�ar UvAJ 7r ALOiVV1.V I � W � ®2011 BN/PR ArcAitects, Tnc, C �,� �, f ,. .., '`� �,,.f . .. .,t.•.. _ .���, ., �•_ . � . - _ � �,... .. _,.";i><�•-. _ � i+ . .. '+ .. � - i,. _ `.�n''�rf �` - . � .-� TI:�F:3t -•i��, :, � _ �� Iti. w J L� Z (D M w 0 WE 0 N 0 11 Ln 0 J W DIVISION 16 - ELECTRICAL SECTION 16010 - GENERAL ELECTRICAL PROVISIONS A. GENERAL 1. TRANSPORTATION, INSURANCE, TEMPORARY PROTECTION, SUPERVISION AND INCIDENTAL ITEMS ESSENTIAL FOR PROPER INSTALLATION AND OPERATION, THOUGH NOT SPECIFICALLY MENTIONED OR INDICATED BUT WHICH ARE USUALLY PROVIDED OR ARE ESSENTIAL FOR PROPER INSTALLATION AND OPERATION OF ALL SYSTEMS RELATED TO THIS SECTION, AS SPECIFIED HEREIN. 2. ALL MATERIALS SHALL BE NEW AND BARE A UL LABEL. 3. ALL CONDUITS, WIREWAYS OR IOTHER ELECTRICAL RACEWAYS PASSING THROUGH FIRE PARTITIONS. FIRE WALLS OR FLOORS SHALL HAVE A FIRE STOP INSTALLED PROVIDING AN EFFECTIVE BARRIER AGAINST THE SPREAD OF FIRE, SMOKE AND GASES, MAINTAINING THE REQUIRED FIRE RATING. B. CODES AND REGULATIONS I. INSTALLATION SHALL CONFORM TO THE FOLLOWING CODES AND REGULATIONS. FLORIDA BUILDING CODE - 2007 WITH 2O09 REVISIONS; APPLICABLE LOCAL CODES. 2. IN THESE SPECIFICATIONS, REFERENCES MADE TO THE FOLLOWING INDUSTRY STANDARDS AND CODE BODIES ARE INTENDED TO INDICATE THE LATEST VOLUME OR PUBLICATION OF THE STANDARD. ALL EQUIPMENT, MATERIALS AND DETAILS OF INSTALLATION SHALL COMPLY WITH THE REOUIREMEN ANSI- AMERICAN NATIONAL STANDARDS INSTITUTE. ASTM- AMERICAN SOCIETY OF TESTING MATERIALS AWG- AMERICAN WIRE GAUGE FM- FACTORY MUTUAL NEMA- NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION UL- UNDERWRITER'S LABORATORIES NETA- NATIONAL ELECTRICAL TESTING ASSOCIATION IEEE- INSTITUTE OF ELECTRICAL AND ELECTRONIC ENGINEERS 3. ALL MATERIALS AND WORKMANSHIP SHALL COMPLY WITH ALL APPLICABLE CODES, STANDARDS, LOCAL AND STATE ORDINANCES. INDUSTRY STANDARDS AND UTILITY COMPANY REGULATIONS. LATEST EDITIONS. C. SCOPE OF WORK I. COOPERATE WITH ALL TRADES TO ASSURE THE STEADY PROGRESS OF ALL WORK UNDER THE CONTRACT, AS WELL AS PROVIDING TEMPORARY POWER AT PROJECT SITE FOR ALL OTHERS. 2. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO STUDY ALL DRAWINGS AND DETAILS SO THAT THE INSTALLATION OF ALL NEW WORK CAN BE FULLY COORDINATED. THE CONTRACTOR SHALL VISIT THE SITE TO SATISFY HIMSELF THAT ALL PROVISIONS HAVE BEEN MADE FOR ALL ASPECTS OF THIS PROJECT. IF DISCREPANCIES EXIST BETWEEN DRAWINGS AND/OR SITE CONDITIONS. THE CONTRACTOR SHALL NOTIFY THE GENERAL CONTRACTOR IN WRITING PRIOR TO SIGNING OF THE CONTRACT FOR CONSIDERATION AND DECISIONS BEFORE PROCEEDING. FAILURE TO DO SO WILL NOT BE ALLOWED AS A BASIS FOR ADDITIONAL COMPENSATION TO CORRECT A DIFFICULTY OF DIFFERENCE FROM CONDITIONS INFERRED OR INDICATED ON THE DRAWINGS. 3. PREPARE AND SUBMIT SHOP DRAWINGS OF PERTINENT ELECTRICAL EQUIPMENT, DEVICES, ETC., AS ARE INDICATED IN THE SCOPE OF WORK, AND RECORD FOR ALL WORK PROVIDED UNDER THIS CONTRACT TO THE ARCHITECT/ENGINEER'S REVIEW. PROVIDE SEVEN (7) COPIES OF ALL SUBMITTALS AS NOTED HEREINAFTER. 4. THE CONTRACTOR, FOR THE WORK IN HIS SCOPE OF WORK, SHALL GIVE ALL NECESSARY NOTICES, OBTAIN ALL PERMITS, PAY ALL GOVERNMENTAL TAXES, FEES. INSPECTIONS. AND OTHER COSTS IN CONNECTION WITH HIS WORK; FILE FOR NECESSARY APPROVALS WITH THE JURISDICTION UNDER WHICH THE WORK IS TO BE PERFORMED. ELECTRICAL CONTRACTOR SHALL OBTAIN ALL REQUIRED CERTIFICATES OF INSPECTION FOR RESPECTIVE WORK AND DELIVER SAME TO THE GENERAL CONTRACTOR BEFORE REQUEST FOR ACCEPTANCE OF HIS PORTION OF WORK IS MADE AND BEFORE FINAL PAYMENT. 5. CUT ALL OPENINGS, CHASES AND PATCHING REQUIRED TO ACCOMMODATE THE WORK UNDER THIS DIVISION, SEAL WITH ACOUSTICAL CAULK AND/OR BLOWOUT PATCH AND REPAIR ALL FLOORS. WALLS, ETC.. DAMAGED BY SUCH CUTTINGS. ALL WORK DONE UNDER THIS HEADING MUST CONFORM IN EVERY RESPECT TO FINISH AND QUALITY OF MATERIALS AND WORKMANSHIP SPECIFIED UNDER APPROPRIATE SECTIONS FOR THE BUILDING. ALL CUTTING, CORE DRILLING, ETC. REQUIRED FOR THE INSTALLATION OF THE ELECTRICAL EQUIPMENT SHALL BE BY THE CONTRACTOR. APPROVED BY THE OWNER. 6. VERIFY EQUIPMENT SIZES, VOLTAGE AND CURRENT CHARACTERISTICS, ETC. BEFORE THE ORDERING OF ANY EQUIPMENT AND BEFORE ROUGHING -IN FOR EQUIPMENT TO BE SUPPLIED BY OTHERS, AND PROVIDE READY ACCESSIBILITY OF SYSTEM REQUIRED TO BE REACHED FOR MAINTENANCE AND OPERATIONS. 7. CHECK OTHER SECTIONS OF THE SPECIFICATIONS FOR EQUIPMENT TO BE CONNECTED UNDER THIS CONTRACT. B. THE ELECTRICAL CONTRACTOR SHALL MAKE ALL REQUESTS FOR SYSTEMS SHUT DOWNS TO THE OWNER 72 HOURS IN ADVANCE AND SHALL RESTORE ALL SYSTEMS TO NORMAL OPERATIONS BY 3:3OPM EVERY WORK DAY. 9.THE ENTIRE AREA SHALL BE BROUGHT UP TO MEET CODE REQUIREMENTS INCLUDING EXISTING CONDITIONS. 10. ALL ABANDONED UTILITIES SHALL BE REMOVED. D. THE FOLLOWING GENERAL SYSTEMS AND EQUIPMENT SHALL BE PROVIDED AS A MINIMUM. BUT NOT BE LIMITED TO THE FOLLOWING: NORMAL DISTRIBUTION SYSTEM. EMERGENCY DISTRIBUTION SYSTEM. GROUNDING. LIGHTING FIXTURES INCLUDING LAMPS. CONNECTIONS TO HVAC, PLUMBING, ELEVATORS. EMPTY CONDUIT SYSTEM FOR TELEPHONE/COMMUNICATIONS SYSTEMS. HOISTING, RIGGING, SETTING OF ALL CONDUIT, CABLE AND EQUIPMENT. TESTING, CLEANING AND ADJUSTING. FEES, PERMITS, ROYALTIES, GUARANTEES. FIRESTOPPING, SMOKEPROOFING. WATERPROOFING SHOP DRAWINGS. RECORD DRAWINGS. COORDINATION DRAWINGS. FIRE ALARM SYSTEM. CONNECTIONS TO OWNER -FURNISHED EQUIPMENT. ACCESS DOORS. BOXES - JUNCTION. BOXES - OUTLET. BOXES - PULL. CONDUCTORS - 600V. CONDUIT - METALLIC. DISCONNECT SWITCHES. HANGERS AND SUPPORTS. EMPTY CONDUITS FOR TELEVISION SYSTEM. MECHANICAL SUSPENSION CHANNEL. MOTOR DISCONNECT DEVICES. PANELBOARDS - LIGHTING AND DISTRIBUTION. WIRING DEVICES AND DEVICE PLATES. SUBMITTALS AND APPROVALS OF ALL STATE AND LOCAL AUTHORITIES. DIMMERS. LIGHTING CONTROL SYSTEMS. SECTION 16110 - RACEWAYS A. RACEWAYS SHALL BE AS FOLLOWS: 1. RACEWAYS FOR FEEDERS AND BRANCH CIRCUITS SHALL BE METALLIC, RIGID METAL CONDUIT, INTERMEDIATE METAL CONDUIT (IMC) OR ELECTRICAL METALLIC TUBING (EMT) SUBJECT TO THE RESTRICTIONS OF THE NATIONAL ELECTRICAL CODE, MINIMUM SIZE3/4. EMT SHALL NOT BE USED IN CONCRETE CONSTRUCTION OR WHERE SUBJECTED TO MECHANICAL DAMAGE. 2. FLEXIBLE METAL CONDUIT SHALL BE USED ONLY FOR CONNECTION TO MOTORS, PUMPS, AIR HANDLING UNITS AND TRANSFORMERS, AND SHALL BE WATERPROOF TYPE. WITH AN INTERWOVEN GROUND CONDUCTOR. SEPARATE GROUND CONDUCTOR SHALL BE INSTALLED IN ALL FLEXIBLE CONDUIT SIZES. FLEXIBLE CONDUIT NON -WATERPROOF TYPE CAN BE USED FOR CONNECTING TO LIGHTING FIXTURES ONLY. MAXIMUM LENGTH OF ALL FLEXIBLE CONDUIT ALLOWED SHALL BE 5'-04. 3. EXPANSION FITTINGS SHALL BE USED WHERE CONDUIT PASSES THROUGH BUILDING EXPANSION JOINTS, WEATHERPROOF TELESCOPIC TYPE. THE EXPANSION FITTING SHALL PERMIT A MINIMUM MOVEMENT OF 4'. 4. SET SCREW TYPE CONNECTORS AND COUPLINGS WILL NOT BE ALLOWED, EXCEPT FOR EMT TYPE CONDUIT. EMT FITTINGS SHALL BE ANSI C80.4 STEEL TYPE, INSULATED THROAT. GLAND COMPRESSION TYPE OR SET SCREW TYPE. DIECAST FITTINGS ARE NOT ACCEPTABLE. 5. RACEWAYS SHALL NOT BE ALLOWED IN ANY CONCRETE FLOOR SLABS. 6. ALL EMERGENCY SYSTEM WIRING SHALL BE INSTALLED IN CONDUIT. 7. PROVIDE ALL MATERIALS, DEVICES, HANGERS, CLAMPS, ETC. AND LABOR REQUIRED TO PROPERLY SUPPORT ALL CONDUITS/BOXES INSTALLED UNDER THIS CONTRACT IN ACCORD WITH NEC. PROVIDE MINIMUM OF 1' SEPARATION BETWEEN ALL CONDUITS RACKED TOGETHER. 8. CONDUIT AND BOXES IN CEILING SPACES SHALL BE SUPPORTED FROM STRUCTURE. 9. PROVIDE NYLON PULL STRINGS IN ALL EMPTY CONDUITS. 10. CONDUIT AND TUBING SHALL BE MANUFACTURED BY ONE OF THE FOLLOWING: ANACONDA METALHOSE, RUSSELL & STOLL, OR ALLIED TUBE & CONDUIT. 11. FLEXIBLE CONDUIT SHALL BE MANUFACTURED BY ONE OF THE FOLLOWING: ANACONDA METALHOSE, RUSSELL & STOLL, OR ALLIED TUBE & CONDUIT. SECTION 16120 - CONDUCTORS A. FEEDERS 1. 600V FEEDERS SHALL BE SINGLE -CONDUCTOR. 600V RATED WITH XHHW OR XHHW-2 INSULATION. FEEDERS SHALL BE COLOR -CODED USING COLOR TAPE AT ALL CONNECTIONS AND IN ALL PULL AND JUNCTION BOXES. ALL FEEDERS SHALL BE INSTALLED IN CONDUIT. ALL WIRING •B AWG AND LARGER SHALL BE STRANDED. 2• PROVIDE COLOR -CODED CABLE SYSTEM APPROVED BY OWNER. IF NONE IS REQUIRED BY OWNER, PROVIDE THE FOLLOWING COLOR -CODING: a. 208/120V (1) A PHASE: BLACK (2) B PHASE: RED (3) C PHASE: BLUE (4) NEUTRAL: WHITE (5) GROUND: GREEN b. 480/277V: (1) A PHASE: BROWN (2) B PHASE: ORANGE (3) C PHASE: YELLOW (4) NEUTRAL: GRAY (5) GROUND: GREEN NOTE: COLOR -CODING SHALL BE CONTINUOUS ON INSULATION FOR 06 AWG OR SMALLER AND CONTINUOUS OR MARKED WITH COLOR TAPE AT ALL CONNECTIONS FOR CONDUCTORS LARGER THAN •6 AWG. B. BRANCH CIRCUITS 1. BRANCH CIRCUIT CONDUCTORS SHALL BE SINGLE -CONDUCTORS 600V RATED WITH THWN OR THHN INSULATION WITH CONTINUOUS COLOR -CODING. 2• BRANCH CIRCUIT CONDUCTOR SHALL BE DESIGNEDD TO UTILIZE THE ADVANTAGE OF MULTI -WIRE DISTRIBUTION. HOWEVER. NO MORE THAN (5) CONDUCTORS (3-PHASE. 1 NEUTRAL AND 1 GROUND) SHALL BE INSTALLED IN A COMMON CONDUIT. 3. MINIMUM SIZE WIRE FOR BRANCH CIRCUIT AND POWER WIRING SHALL BE •12 AWG. FOR REMOTE CONTROL SIGNAL CIRCUIT AND INTERLOCK WIRING CAN BE 014 AWG. FOR 20A BRANCH CIRCUIT RUNS EXCEEDING 100'-O' IN LENGTH FROM PANELBOARD TO THE FIRST OUTLET, THE ENTIRE BRANCH CIRCUIT RUN SHALL BE 010 AWG OR LARGER. FOR RUNS OVER 175'-0' TO THE FIRST OUTLET, USE •8 AWG OR LARGER FOR THE ENTIRE BRANCH CIRCUIT RUN. 4. MULTICONDUCTOR ARMORED CABLE (HOSPITAL GRADE)MAY BE USED FOR NORMAL POWER, GENERAL PURPOSE 20A BRANCH CIRCUIT WIRING FOR RECEPTACLES AND LIGHTING FIXTURES ONLY, 60OV, COPPER, WITH A BONDING WIRE CONDUCTOR OR THE METAL SHEATHING OF CABLE SHALL NOT BE USED AS THE GROUNDING CONDUCTOR, BUT SHALL BE USED AS A SECOND PATH FOR GROUNDING PER NEC, TO BOND METALLIC SHEATHING TO OTHER WIRING METHODS. ALL ARMORED CABLES WHERE INSTALLED SHALL BE RUN CONCEALED. THIS WIRING METHOD USING ARMORED CABLE OR ANY OTHER ASSEMBLED CABLE(S)SHALL NOT BE USED FOR EMERGENCY SYSTEM BRANCH/FEEDER CIRCUITS. ARMORED CABLE SHALL BE UL LISTED FOR HOSPITAL USE AND SHALL COMPLY WITH FEDERAL SPECIFICATION J-C-30 AND SHALL BE MANUFACTURED BY AFC OR APPROVED EQUAL. ARMORED CLAD CABLE CONDUCTORS SHALL BE COLOR -CODED. CONTINUOUS ON INSULATION AS CALLED FOR HEREIN BEFORE. 5. BRANCH CIRCUIT AND FEEDER CONDUCTORS SHALL BE MANUFACTURED BY ONE OF THE FOLLOWING: CAROL CABLE, OKONITE. PIRELLI OR ROME CABLE CORP. C. ALL WIRE AND CABLE SHALL BE ANNEALED, COATED COPPER PER ASTM B 33 OR B 189 WITH CONDUCTIVITY OF NOT LESS THAN 98 PERCENT. ALL WIRE SHALL BE STRANDED, UNLESS SIZE 8 OR SMALLER, CLASS B PER ASTM B8. D. ALL WIRE SHALL HAVE 600 VOLT INSULATION, UL LISTED AND COMPLYING WITH UL83, ICEA S-61-402 OR ICEA S-66-524 FOR RESPECTIVE INSULATION TYPE AND SHALL BE COLOR -CODED. SECTION 16130 - BOXES A. BOXES SHALL BE AS FOLLOWS: I. GALVANIZED STEEL OUTLET BOXES CONFORMING TO UL STANDARD NO. 514 WILL BE USED FOR CONCEALED OUTLETS. 2. EXPOSED OUTLET BOXES SHALL BE CAST -METAL CONDUIT TYPE FS OR FD WITH THREADED HUBS. 3. PULL AND JUNCTION BOXES SHALL CONFORM TO UL STANDARD 50.CONSTRUCTED OF CODE GAUGE GALVANIZED STEEL AND BE SIZED PER THE REQUIREMENTS OF THE NATIONAL ELECTRIC CODE. 4. PROVIDE PULL AND JUNCTION BOXES AS REQUIRED. 5. ALL JUNCTION AND PULL BOXES FOR EMERGENCY SYSTEMS AND LOW VOLTAGE SYSTEMS SHALL HAVE COVER PLATES PAINTED. COLORS FOR COVERS SHALL BE AS INDICATED BELOW: LIFE SAFETY BRANCH YELLOW CRITICAL BRANCH ORANGE EQUIPMENT BRANCH GREEN FIRE ALARM RED DATA/TELEPHONE SYSTEM BROWN SECTION 16140 - WIRING DEVICES A. LIGHT SWITCHES 1. SWITCHES SHALL BE FULL SIZE, HEAVY DUTY, AC TYPE, RATED FOR 120/277 VOLTS. HUBBELL *122-1. 01223-1. 01224-1. 2. DIMMERS SHALL BE 120 VOLTS, 600. 1000 AND 1500 WATTS WITH SLIDER CONTROL. COLOR SELECTED BY ARCHITECT, MANUFACTURED BY LUTRON N2000 SERIES OR APPROVED EQUAL. WATTAGE OF CONNECTED LOAD TO THE DIMMER SHALL NOT EXCEED 80 PERCENT OF DIMMER RATING. B. DUPLEX,RECEPTACLES I. DUPLEX RECEPTACLES SHALL BE SPECIFICATION GRADE. U-GROUND, RATED FOR 120 VOLTS,20 AMPERES. CATALOG NUMBERS ARE AS FOLLOWS:HUBBELL *5362. C. DEVICE PLATES I. SWITCH DEVICE PLATES SHALL BE MANUFACTURED OF NYLON. COLOR SHALL BE AS SELECTED BY THE ARCHITECT. DEVICE PLATES SHALL BE NYLON AND OF THE SAME MANUFACTURER AS WIRING DEVICES. DEVICE PLATE SCREWS SHALL MATCH PLATES. D. RECEPTACLES AND LIGHT SWITCHES ON EMERGENCY POWER SHALL BE RED IN COLOR WITH RED DEVICE PLATES. SECTION 16170 - CIRCUIT AND MOTOR DISCONNECTS A. DISCONNECT SWITCHES SHALL BE AS FOLLOWS: I. FURNISH AND INSTALL DISCONNECT SWITCHES FOR DISCONNECTING MEANS FOR ALL EQUIPMENT. DISCONNECT SWITCHES SHALL BE OF THE TYPE 'A', QUICK -MAKE. QUICK -BREAK CONSTRUCTION. DISCONNECT SWITCHES SHALL HAVE INTERLOCKING DOORS. CABINETS SHALL BE BONDERIZED AND FINISHED IN GRAY ENAMEL. NEMA TYPE 313 ENCLOSURES SHALL BE USED WHERE THE DISCONNECT SWITCH IS EXPOSED TO THE WEATHER OR IN WET AREAS. 2- DISCONNECT DEVICES SHALL BE ONE OF THE FOLLOWING MANUFACTURERS: SQUARE D. GENERAL ELECTRIC OR WESTINGHOUSE. 3. ALL EQUIPMENT SHALL BE PROVIDED WITH THE PROPER SIZE/RATING DISCONNECT SWITCH WHETHER INDICATED ON THE DRAWINGS OR NOT TO COMPLY WITH NEC. ALSO, INSTALL AND CONNECT DISCONNECT SWITCHES FURNISHED BY OTHER TRADES. SECTION 16190 - SUPPORTS A. PROVIDE SUPPORTS AS FOLLOWS: 1. ALL SUPPORTS REQUIRED TO PROPERLY SUPPORT ALL EQUIPMENT, DEVICES, RACEWAYS, ETC. TO BE INSTALLED UNDER THIS CONTRACT. 2. PROVIDE SUPPORTS AS REQUIRED BY THE NEC. SECTION 16195 - IDENTIFICATION A. EQUIPMENT IDENTIFICATION I. PROVIDE ENGRAVED LAMINATED PHENOLIC NAMEPLATES TO IDENTIFY PANELBOARDS DISCONNECTS AND ALL MAJOR EQUIPMENT. 2. NAMEPLATES SHALL INCLUDE THE PANEL AND CIRCUIT DESIGNATION AND SHALL BE LAMINATED, BAKELITE WITHI/4 HIGH. RECESSED LETTERS. NAMEPLATES SHALL BE SECURELY ATTACHED TO THE EQUIPMENT WITH GALVANIZED SCREWS. ADHESIVES OR CEMENTS SHALL NOT BE USED. 3. NAMEPLATE FOR EQUIPMENT ON NORMAL POWER SHALL BE BLACK IN COLOR WITH WHITE RECESSED LETTERS. 4. NAMEPLATES FOR DEVICES ON EMERGENCY POWER SHALL BE 'RED' IN COLOR WITH WHITE RECESSED LETTERS. 5. FURNISHING AND INSTALLING PERMANENT IDENTIFICATION MARKERS FOR ALL ELECTRICAL EQUIPMENT AND RACEWAYS INSTALLED UNDER THIS CONTRACT. 6. NAMEPLATES SHALL INCLUDE THE FOLLOWING INFORMATION: a. EQUIPMENT IDENTIFICATION: SERVICE VOLTAGE -PHASE -WIRE, BRANCH OF POWER CONNECTED TO, AND SOURCE OF POWER THE EQUIPMENT IS FED FROM. 7. ALL PANELBOARDS SHALL BE PROVIDED WITH NEW WRITTEN DIRECTORIES. ALL DIRECTORIES SHALL INDICATE LOADS SERVED AS WELL AS BREAKER RATINGS AND POLE SPACE REQUIREMENTS FOR EACH LOAD. THIS REQUIREMENT APPLIES TO ALL NEW OR REVISED PANELBOARDS. PROVIDE COPY OF ALL DIRECTORIES TO ENGINEER OF RECORD. 8. THE CONTRACTORS SHALL BE RESPONSIBLE FOR TRACING OUT EXISTING BRANCH CIRCUITS AND UPDATING PANEL DIRECTORIES AS REQUIRED TO INSURE PROPER DIRECTORY LISTINGS. B. CONDUIT IDENTIFICATION: I. PROVIDE MANUFACTURER'S STANDARD PRE-PRINTED. FLEXIBLE OR SEMI -RIGID, PERMANENT, PLASTIC -SHEET CONDUIT MARKERS, EXTENDING 360 DEGREES AROUND CONDUITS, DESIGNED FOR ATTACHMENT TO CONDUIT BY ADHESIVE, ADHESIVE LAP JOINT OF MARKER, MATCHING ADHESIVE PLASTIC TAPE AT EACH END OF MARKER, OR PRETENSIONED SNAP -ON. EXCEPT AS OTHERWISE INDICATED, PROVIDE LETTERING WHICH INDICATES VOLTAGE OF CONDUCTORS) IN CONDUIT. PROVIDE MINIMUM 8 INCH LENGTH FOR 2-INCH AND SMALLER CONDUIT, 12-INCH LENGTH FOR LARGER CONDUIT. 2. PAINT CONDUITS FOR EMERGENCY SYSTEMS AND LOW VOLTAGE SYSTEMS IN ACCORD WITH TABLE 1 OF THIS SECTION. SPACING OF PAINT MARKINGS SHALL BE 10'-O' ON CENTERS FOR ENTIRE LENGTH OF CONDUIT. C. COLOR -CODE TAPE I. COLORED TAPE SHALL BE POLYVINYL CHLORIDE, SELF-ADHESIVE NOT LESS THAN 3 MILS THICK AND 1-1/2 INCH WIDE, SUITABLE FOR USE ON 90 DEGREE C CONDUCTORS, UL LISTED AND SHALL BE FURNISHED IN COLORS AS SPECIFIED HEREIN. SECTION 16198 - TESTING A. ALLOW VOLTAGE 600V EQUIPMENT, CABLE, MOTORS, DRY TYPE TRANSFORMERS, ETC., SHALL BE FIELD TESTED PER NETA STANDARDS. SECTION 16450 - GROUNDING A. A COMPLETE EQUIPMENT GROUNDING SYSTEM SHALL BE PROVIDED SUCH THAT ALL METALLIC STRUCTURES, ENCLOSURES, RACEWAYS, JUNCTION BOXES, OUTLET BOXES, CABINETS, MACHINE FRAMES METAL FENCES, AND ALL OTHER CONDUCTIVE ITEMS OPERATE CONTINUOUSLY AT GROUND POTENTIAL AND PROVIDE A LOW IMPEDANCE PATH TO GROUND FOR POSSIBLE FAULT CURRENTS. B. A SEPARATE INSULATED GREEN GROUNDING CONDUCTOR SHALL BE PROVIDED FOR EACH SINGLE AND 3-PHASE FEEDER AND BRANCH CIRCUIT. GROUNDING CONDUCTOR SHALL BE RUN WITH THE RELATED PHASE AND NEUTRAL CONDUCTORS. PANEL FEEDERS INSTALLED IN MORE THAN (1) RACEWAY SHALL HAVE INDIVIDUAL, FULL SIZED, GREEN GROUNDING CONDUCTOR IN EACH RACEWAY. THE EQUIPMENT GROUNDING SYSTEM SHALL NOT RELY ON THE METALLIC RACEWAYS FOR GROUNDING CONTINUITY. C. PROVIDE BONDING OF ALL EQUIPMENT IN ACCORDANCE WITH NFPA-70. D. IN PATIENT CARE AREAS, TEST THE EFFECTIVENESS OF THE GROUNDING BY VOLTAGE AND IMPEDANCE MEASUREMENTS. MAKE MEASUREMENTS AS REQUIRED BY NFPA 99. SECTION 3-5.2.1 THE TIME OF FINAL INSPECTION BY THESE AUTHORITIES. 1. EMPLOY TEST INSTRUMENTS EQUAL TO THOSE SPECIFIED IN NFPA 99. 2. CORRECT ANY WIRING FOUND DEFICIENT. 3. TESTS SHALL BE PERFORMED AND CERTIFIED BY A MASTER ELECTRICIAN LICENSED IN THE JURISDICTION. 4. PATIENT CARE AREAS ARE DEFINED AS PATIENT ROOMS, TREATMENT AND EXAMINATION ROOMS. CRITICAL CARE AREAS AND ANY SPACES WHERE PATIENTS ARE DOMICILED, EXAMINED, EVALUATED OR TREATED. SECTION 16721 - FIRE ALARM AND DETECTION SYSTEM A. THE CONTRACTOR SHALL PROVIDE CONNECTION TO THE OWNERS EXISTING FIRE ALARM SYSTEM. PROVIDE ALL NECESSARY SYSTEM CABINETS, POWER SUPPLIES, MICRO -CONTROLLERS, KEYBOARD DISPLAYS, LED DISPLAYS, BATTERIES, PERIPHERAL DEVICES, VOICE EVACUATION SYSTEMS, ETC. FOR A COMPLETE AND FUNCTIONING SYSTEM. FIRE ALARM SYSTEM COMPONENTS SHALL MATCH EXISTING. B. THE SYSTEM SHALL COMPLY WITH ALL CURRENT, APPLICABLE CODES INCLUDING THE FOLLOWING: 1. NATIONAL ELECTRICAL CODE (NEC) 2. NATIONAL FIRE PROTECTION AGENCY a. NFPA 72 EDITION b. NFPA 101 LIFE SAFETY CODE 3. ALL APPLICABLE UL STANDARDS 4. AMERICANS WITH DISABILITIES ACT (ADA) 5. LOCAL CODE REQUIREMENTS C. CONTROL PANEL 1. THE CONTRACTOR SHALL PROVIDE ALL NECESSARY HARDWARE AND SOFTWARE PROGRAMMING NECESSARY TO ACCOMMODATE MODIFICATIONS INDICATED ON DRAWINGS. D. BUILDING AUTOMATION SYSTEM INTERFACE I. WHERE REQUIRED, THE FIRE ALARM SYSTEM SHALL BE INTERFACED WITH THE BUILDING AUTOMATION SYSTEM (AUTOMATIC TEMPERATURE CONTROL SYSTEM) TO SEND AND RECEIVE SIGNALS FROM ALARM INITIATING DEVICES AND H-O-A SWITCHES FOR THE OPERATION OF SMOKE CONTROL SYSTEMS, FAN SHUTDOWN AND COMMUNICATIONS. COORDINATE ALL REQUIREMENTS WITH DIVISION 15000. E. ALARM INITIATING DEVICES I. PROVIDE ALL ALARM INITIATING DEVICES AS INDICATED ON FLOOR PLANS. DEVICES SHALL MATCH EXISTING. WHERE SHOWN PROVIDE ALL MANUAL PULL STATIONS. SMOKE DETECTORS, HEAT DETECTORS, FLOW SWITCHES, AND TAMPER SWITCHES. PROVIDE CONNECTION TO ALL DOOR RELEASE CIRCUITS AND ANCILLARY FIRE ALARM FUNCTIONS AS INDICATED ON DRAWINGS. F. ALARM INDICATING DEVICES I. VISUAL STROBE UNITS SHALL MEET THE REQUIREMENTS OF ADA, UL AND NFPA. 2. AUDIBLE UNITS IN PUBLIC AND STAFF SPACES SHALL BE SPEAKERS WITH A PEAK OUTPUT OF 96 dB AT 10'-0'. 3. AUDIBLE UNITS IN MECHANICAL AREAS OR OTHER AREAS WITH HIGH AMBIENT NOISE SHALL BE TRUMPET TYPE SUITABLE FOR SUCH LOCATIONS. G. WIRING 1. ALL FIRE ALARM WIRING SHALL BE SUPERVISED. ALL WIRE AND CABLE SHALL BE SUITABLE FOR FIRE ALARM USE AND SHALL BE INSTALLED IN CONDUIT. 2. ALL WIRING SHALL BE STRANDED AND COLOR -CODED PER THE HOSPITAL'S STANDARDS. H. TESTING 1- THE ENTIRE SYSTEM SHALL BE TESTED TO THE SATISFACTION OF THE OWNER AFTER WHICH A FINAL ACCEPTANCE TEST WITNESSED BY THE LOCAL AUTHORITY, THE OWNER'S BUILDING CONSTRUCTION DEPARTMENT AND AHCA. SECTION 16740 - EMPTY RACEWAY SYSTEM A. AN EMPTY RACEWAY SYSTEM SHALL BE PROVIDED FOR USE BY THE TELECOMMUNICATION VENDOR FOR THE PULLING IN OF TELECOMMUNICATIONS WIRING AND EQUIPMENT. THE RACEWAY SYSTEM SHALL MEET THE EIA/TIA-569 STANDARDS. B. TELECOMMUNICATIONS OUTLETS 1. EACH TELECOMMUNICATION OUTLET SHALL CONSIST OF A 41 %� SQUARE OUTLET BOX WITH SINGLE -GANG ADAPTOR AND BLANK COVER PLATE./,� CONDUIT SHALL RUN FROM THE OUTLET TO NEAREST ACCESSIBLE CORRIDOR CEILING. C. FURNISH AND INSTALL EMPTY CONDUIT OUTLETS AND MOUNTING BOARDS FOR MATV AND SECURITY SYSTEMS. D. OUTLET BOXES FOR ALL SYSTEMS SHALL BE 41 Yid SQUARE (NO ROUNDED CORNER) WITH RAISED COVER AND FACEPLATES (CONSULT OWNER FOR THE APPROPRIATE FACEPLATE). SIMILAR TO WIRING DEVICE PLATES. E. PROVIDE POWER REQUIREMENTS SUCH AS DUPLEX OUTLETS AND GROUND TERMINAL CONNECTIONS FOR THE TELEPHONE EMPTY CONDUIT SYSTEM, AS REQUIRED BY THE VENDOR. F. A MINIMUM:Yle DIAMETER, TWISTED NYLON PLASTIC FISH CORD SHALL BE FURNISHED AND INSTALLED IN ALL EMPTY RACEWAYS. PROVIDE A TAG ON EACH END OF FISH CORD INDICATING THE LOCATION OF THE OTHER END. CONDUITS SHALL BE OF SIZE NOT SMALLER THAN3/4. G. ALL EMPTY CONDUIT RUNS FROM OUTLETS SHALL TERMINATE ABOVE AN ACCESSIBLE CORRIDOR SUSPENDED CEILING. H. WHERE CORRIDORS HAVE NON -ACCESSIBLE CEILINGS, PROVIDE CONDUIT SLEEVES AS A MINIMUM ONE (1) PER SYSTEM, COVERING THE ENTIRE LENGTH OF NON -ACCESSIBLE CEILING CAVITY. NUMBER AND SIZE OF CONDUIT/SLEEVES SHALL BE PER EQUIPMENT MANUFACTURER'S CABLING REQUIREMENTS. k1;ERSmith Seckman Reid, Inc. 600 West Hillsboro, Suite 300 Deerfield Beach, FL 33441 (954)421-1260 FAX: (954) 421-1466 www.ssr-inc.com Firm Certification - EB-0000857 Dennis Davie PE - 58588 John E. Moulder PE- 33200 SSR JOB # 1137001.0 w0pal 0iffiv-10"'a �%��C�N�S'"Q,'Q / 88 =od .9� r 44 p ; 5 ATE OF iS **/sIONAt��,�`. I R Q Q� N W Q_ O W 0 .L_ _O LL I 0) .:3 M � U _O 14 - C� O U CIO _U U Q_ a) c U 1` O .) N W r Project No. 11006.00 E5.1 02011 BUK Architects, Inc. -...r 1J WN f:_ €°y13 . ..P_. .1.4Y.S