Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
3112 Kresterbrooke Ln
INDEX OF DRAWINGS SHEET DESCRIPTION SHEET No. CS COVER SHEET 1 MAIN FLOOR PLAN 1 UPPER FLOOR PLAN 2 INTERIOR ELEVATIONS 3.1 EXTERIOR ELEVATIONS 3.2 EXTERIOR ELEVATIONS F1 FOAM DETAILS 4 MAIN ELECTRICAL PLAN 4.1 UPPER ELECTRICAL PLAN 5 MAIN ROOF PLAN 6 FOUNDATION PLAN 7 FLOOR/ROOF FRAMING PLAN 7.1 ROOF FRAMING PLAN 8 LINTEL DETAILS SN STRUCTURAL NOTES SN1 DETAILS MillirS3 DETAILS S4 DETAILS S5 DETAILS S6 DETAILS ST STAIR DETAILS ABBREVIATIONS SS RETROFIT DETAILS D1 SECTIONS &DETAILS A.B. Anchor Bolt F.P. Fireplace P.T. Pressure Treated Abv. Above F.O.M. Face Of Masonry Pwd. Powder Room A/C Air -Conditioner , SECTIONS &DETAILS Ft. Foot/ Feet Red. Radius WP WATERPROOFING DETAILS ADJ. Adjustable Ft . Footing Ref. Refrigerator A.F.F. Above Finished Floor g PA1.0 PRODUCT APPROVAL NUMBERS A.H.U. Air Handler Unit FIX Fixed Req'd. Required ALT. Alternate Galy. Galvanized Rm. Room PA1.1 PRODUCTAPPROVAL NUMBERS B.A. Base Cabinet G.C. General Contractor Rnd. Round BF Bifold Door G.F.I. Ground Fault Interrupter R/S Rod and Shelf _- PA1.2 PRODUCT APPROVAL NUMBERS Bk Sh BookShelf G.T. Girder Truss SD. Smoke Detector PA1.3 PRODUCT APPROVAL NUMBERS Bm. Beam Hdr. Header S.F. Square Ft. Bot. Bottom Hgt. Height Sh. Shelves B.P. Bypass door HB Hose Bibb SHT Sheet BRG. Bearing Cir. Circle Int. Interior S.L. Side Lights Clg. Ceiling M%11 Kneewall S.P.F. Spruce Pine Fir CJ Control Joint K.S. Knee Space Sq. Square Col. Column Laun. Laundry S.Y.P. Southern Yellow Pine Comm. Community Lay. Lavatory TB Towel Bar Comp. Compressor L.F. Linea ! Temp. Tempered C.T. Ceramic Tile LL Lintel length Thik'n. Thicken D. Dryer LT. Laundry Tub T.O.B. Top of Block DB Door Bell T.O.M. Top of Masonry Dec. Decorative Mas. Masonry Ded. Dedicated Outlet Max Maximum T.O.P. Top Plate Dbl. Double M.C. Medicine Cabinet TR TOWEL RING Dia. Diameter Mfgr. Manufacturer TP TOILET PAPER Disp. Disposal Micro. Microwave Trans. Transom Window Dist. Distance Min Minimum Typ. Typical D.S. Drawer Stack M.L. Microlam U.C. Under Counter D.V. Dryer Vent Mir. Mirror UCL Under Cabinet Lighting D.W. Dishwasher U.N.O. Unless Noted Otherwise Mono Monolithic ALL Ea. Each N.T.S. Not to Scale V. Shower Valves Cod ..5 CO E.W. Each Way Opn'g. Opening VB Vanity Base /�A /0N t.()i"104 St/,� pLY W/p� Elec. Electrical vent. vertical AN A(. E'��r' N � Opt. Optional RQ r t, C Tp/ G CO Elev. Elevation Pc. Piece V.L. Versalam 0 ' '�� �Jrt � ; � �/�� dflF D� �� Ext. Exterior p� pedestal VTR Vent through Roof l ice's Hy t�s Exp. Expansion w Washer FBC Florida Building Code PH PHONE W/ With ll P P.L. araam Fin. Flr. Finished Floor W/C Water Closet F.G. ixed Glass PLF Pounds per linear foot W.A. Wedge Anchor Fir. Floor Pit. HI. Plate Height Wd Wood Pit Sh. Plant Shelf RFV/� Fdn. Foundation WP Water Proof Flr Sys Floor System PSF Pounds per square foot �! REVISIONSE�S 08-20-15 1.00 NEW BASE PLAN 12-08-15 2.0 FRAME -WALK REVISIONS 01-04-18 3.0 2017 FBC UPDATES MEAN ROOF 15 FT. HIGH TYPICAL FOR SINGLE STORY HOMES MEAN ROOF 30 FT. HIGH TYPICAL FOR 2 STORY HOMES THIS DRAWING AND DESIGN IS VALID FOR 12 MONTHS AFTER THE DATE IT IS SIGNED AND SEALED OR WHILE CURRENT CODE IS VALID Notice to Builder & All Subcontractors It is the intent of Designer/Engineer listed in the titleblock of these IF= documents that these documents be accurate, providing Licensed Professionals clear information. Every attempt has been made to prevent error. The Builder and all subcontractors are required to review all the information contained in these documents, prior to the commencement of any work. The Designer/Engineer are not responsible for any plan errors, omissions,or misinterpretations undetected and not reported to the Designer / Engineer prior to construction. All construction MUST be in accordance to the information found in these documents. Any questions regarding the information found in these plans should be directed to our Office at (407) 880-2333 immediately. No backcharges will be 2889 considered for reimbursement by the Designer/Engineer without advanced notification and approval by the Designer/Engineer. Payments will be made in accordance to the terms of the agreement. z z�E3 z Q a z CZ QA p O"' c ~ Cii � W D o m M F$ W~ O LO O O N CD U o -- Q ` U) o QQ 0ao Al1 6 De •o� __; 'W M ,,,raam U) Z �W ate' r: O U To the best of the Engineer'sknoydedae,, � 1 ati d belief, the structural plans and'specirications c d within these drawings comply with the �j.)1,17 Building Code - Residential 6th Edti,16 eer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. i O Z N O�n O Z M Q 'gyp Ln a cn•�� V) LL a .� V M Q o- 00 (0... Z WJ C) d' uJ0 uJ Zaa �a a of Z Z Z �W 0Z J � M W �® $ oo = U Z Z c LU Lr) > 0 Ov Z-) __ o U o n � a� a d- go MR2 Z E J*-{ Q uJ Z ¢dE� a LL Lu ~ N N Z� r 00 g LV a o SCALE : AS NOTED DATE : 3/18/2018 TECH: FFLORES VERSION NO° 10 SHEET NO. C S A J TYP @ 2 S3 S6 STORY H.B. `r I w N�CW. Og _rn ■w I 14'-9„ jII1I w 1m O 36" X 60" SHOWER O SURROUND _-- - - --- i1 p. I.C. I r1 8 -8FLAT CLG. I CARPET 7'-7" 1) 2' 6 iv BUILDER TO PROVIDE APPLIANCE PROTECTION WHEN REQUIRED PER FBC 21,-42" - K IIIIII IFIII - - - - - - - - - - S4 1 1 -0�� wI 3,,28 8 34 TYP @ 2 STORY J S6 = A N OWN E 'S SUITE � 8'-8" LAT CLG. C RPET 4 `~ I o E ~ ■ 1 ~c� 1 I 2068B.F. 9'-A" FLAT LG 2668 LI EN ILE (3) 2X4 #2 SPF G I " o W/ (3)16d S3 5 SH O 16" DEEP : _ AIL _ _ _ _ - J R&S r- +7- P1 W Y ___THANSON BOX O _ 1 1 \ 1 @ 36" A.F.F. iv I DRYER VENT X THRU WALL o „ E - 00 OPj. D 9- - - - - 10 - - - - I __--- 111 N I " 8I 12 T _ LE - - __ I - - V-4" SHELF 5 6 I 13 _ _ - - 14 _ _ - - 5__ __ 15 - 2868 S3 - = - - 6 3 M 0 Hq) 2 CAR GARAGE 8'-8" FLAT CLG. �' °' HALF WALL EDGE OF SLAB 2" BEYOND WALL S3 X 1 1 O I I I t o I I I O w 1 1 I > I I I 1 X 1 1 I cc I Li I r 1 I I I I I I I I 1 I I I I I I I I I I I I I I I I I I L NOTE: FINISHED _ _ w I I WALLS TO BE FLUSH. VERIFY IN FIELD. D S3 10 I" to 1 J 1 o c" T- 9 o +42„SLOPING 0) tom° N _ `? 4'-0" 0 2 0 PATIOI 16 -`}z" 4'-0" 5'-8" 1 3'-4" 3'-112" 18'-9" 8'-8" LAE LG. n2'-0"-0 o W 8 to I (3) 2X4 #2 SPF W! (3)16d TOENAILS oo @ BASE I ofLOW WALL OR z I SPINDLES PER SPEC. 1 ��� I I I ENTRY 8'-8 FLAT CLG. -1 o0 N HDR AT T-4" -I • • - ■ ' 00 ■ = O to N FA I LY R M 8' 8" FLAT CLG. CARPET �TN iio I CAFE 8'-8" FLAT CLG. o0 CARPET t° Ar-- F_: II 0 1 I. 1 I j �-J w jEl III I I I I � I D.W. - I AH Nr NOTE: FINISHED WALLS TO BE FLUSH. VERIFY IN I FIELD. FLEX 8'-8" FLAT CLG. CARPET 1 U) I N 1 TYP @ 2 STORY _ S6 ; iio (V IL I i I O O R I I �B jW �N SH ANTRYEP n Lu r 1 r 26'-31a c -- 4 _ " � '� 12'-44„ O ■ - I rn rn`�2 AC PAD AC PAD I co rn to 5-SH 16" DEEP I IO t Is I I'' 10 IZ LN O 24 - 24 24 OPT. REF. 24 I� H.B. 25-SH A Oq J TYP @ 2 STORY S3 S6 22'-3" �ziyi HEADER SCHEDULE SIZE REMARKS KHEADER (2) - 2X6 #2 SYP W/ 1/2" FLITCH PLATE (2) - 2X8 #2 SYP W/ 1/2" FLITCH PLATE H3 (2) - 2X10 #2 SYP W/ 1/2" FLITCH PLATE H4 (2) - 2X12 #2 SYP W/ 1/2" FLITCH PLATE H5 (2) - 1 3/4" X 11 1/4 LVL 2.0E Fb=2600 PSI H6 (2) - 1 3/4" X 9 1/4" LVL 2.0E Fb=2600 PSI H7 (2) - 1 3/4" X 16" LVL 2.0E Fb=2600 PSI H8 (2) - 1 3/4" X 7 1/4" LVL 2.0E Fb=2600 PSI (2) - 2X4 #2 SYP W/ 1/2" Follow Q/S4. See Plan for R.A.G. FLITCH PLATE Bearing Wall Call Out When Straps are Required * VERIFY W/ PLAN CORRECT LENGTH OF HEADER REQUIRED ** SEE PLAN FOR DETAIL CALL OUT FOR CONNECTIONS AND REQUIRED STUDS WINDOW SCHEDULE SIZE R.O. CMU (Flange) R.O. FRAME (Fin) TYPE 12 20X26 18JX25j S.H. 13 20X38j 184X371 S.H. 14 20 X 501 18 4 X 50 S.H. 15 20X63 184X624 S.H. 16 20X72 184X714 S.H. 432 27 1/4 X 26 26 X 25 J S.H. 433 27 1/4 X 38 1 N/A S.H. 434 27 4 X 50 1 N/A S.H. J 33 N/A 26 x 37 1 S.H. j 34 N/A 26 x 50 S.H. j 35 27 4 X 63 26 X 62 1/2 S.H. j 36 27 4 X 72 26 X 71 1/2 S.H. 22 37JX26 364X251/2 S.H. 23 37 J X 38 i 36 4 X 37 3/4 S.H. 24 37 j X 50 1 36 4 X 50 S.H. 25 37 J X 63 36 j X 62 1/2 S.H. 26 37 J X 72 36 4 X 71 112 S.H. DOUBLE 2 WIDE 75" TALL 73 j WIDE S.H. 32 54 X 26 52 4 X 25 } S.H. 33 54 X 38 j 52 } X 37 J S.H. 34 54 X 501 52 4 X 50 S.H. 35 54 X 63 52 } X 624 S.H. 36 54 X 72 52 j X 71 j S.H. 39X59 40 X 59 N/A S.H. DOUBLE 39X59 79 X 59 N/A S.H. General notes R302.5 Dwelling/Garage Opening/Penetration Protection. • Openings from a private garage directly into a room used for sleeping purposes shall not be permitted. Door between garage and residence shall be equipped with solid doors not less than 1 3/8" in thickness, solid or honeycomb -core steel doors not less than 1 3/8" thick, or 20-minute fire -rated doors. • Duct Penetration. Ducts in the garage and ducts penetrating the walls or ceilings separating the dwelling from the garage shall be constructed of a minimum No. 26 gage (0.48 mm) sheet steel, 1 inch minimum rigid nonmetallic class 0 or classl duct board, or other approved material and shall have no openings into the garage. • Other penetrations shall be protected as required by section R302.11, Item 4. R302.6 Dwelling/Garage Fire Separation. The garage shall be separated from the dwelling as per the following: • From the Residence & Attics - Not Less than 1/2" Gyp. Bd. or equivalent applied to garage side. • From Habitable Rooms Above Garage - Not Less than 5/8" Type-X Gyp. Bd. or equivalent. • Structure(s) Supporting Floor/Ceiling Assemblies - Not Less than 1/2" Gyp. Bd. or equivalent. • Garages Located Less Than 3 Feet From Dwelling On The Same Lot - Not Less than 1/2" Gyp. Bd. or equivalent applied to the interior side of exterior walls that are within this area. R312.2.1 Window Sills. In dwelling units, where the opening of an operable window is located more than 72 inches above the finished grade or surface below, the lowest part of the clear opening of the window shall be a minimum of 24 inches above the finished floor of the room in which the window is Iocated.Operable sections of windows shall not permit openings that allow a 4-inch-diameter sphere where such openings are located within 24 inches of the finished floor. Chapter 45 Private Swiming Pools, Section R4501.17.1.9 All doors and windows providing direct access from the home to the pool shall be equipped with an exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 db a at 10 feet. Any deactivation switch shall be located at least 54 inches above the threshold of the access. Separate alarms are not required for each door or window if sensors wired to a central alarm sound when contact is broken at any opening. M1507.2 Recirculation of Air. Exhaust air form Bathrooms and toilet rooms shall not be recirculated within a residence or to another dwelling unit and shall be exhausted directly to the outdoors. Exhaust air from bathrooms and toilet rooms shall not discharge into an attic , crawl space or other areas inside the building. GAS APPLIANCES G.C. to verify location of gas riser before commencement of work. see Sht. SN1 for installation detail. Where gas water heaters are installed. Water heaters shall be installed a min. of 18" above flr. per FBCR G2408.2. Except where appliances that are listed as flammable vapor ignition resistant. OPENING PRESSURES ENCLOSED-EXPOSURE"C" rA +29.7 / -30.8 W +29.7 / -39.2 © +28.3 / -30.8 CD +28.3 / -36.4 O +26.6 / -28.0 O +26.6 / -32.2 �G SEE SINSHEET ru SEE SN SHEET 140 MPH NOTE: WIND SPEED INDICATED ABOVE IS AN "ULTIMATE" WIND SPEED. THE WIND PRESSURES LISTED ABOVE ARE ALLOWABLE PRESSURES SOFFIT DESIGN PRESSURE 1 +34.0 / -44.8 WALL LEGEND TYP. 2x FRAME WALL BEARING WALL INTERIOR BEARING WALLS NOTED "FLOOR BEARING ONLY" ARE FLOOR SYSTEM SUPPORTING ONLY AND REQUIRES NO UPLIFT CONNECTORS TO FLOOR SYSTEM AREA TABULATION "A1" 1ST FLOOR LIVING AREA 1793 2ND FLOOR LIVING AREA 1103 LIVING TOTAL 2896 GARAGE 437 FRONT ENTRY 26 TOTAL AREA 3359 INSULATION REQ. LOCATION I R-VALUE / TYPE EXT FRAME 2 x 4 R-11/R-13 KRAFT FACED EXT FRAME 2 x 6 R-19 KRAFT FACED CONDITIONED CEILING R-30 BLOWN -IN (INSTALL BAFFELS AT EAVE) GARAGE SEPARATION R-11/R-13 KRAFT FACED (GARAGE / LIVING) 0 0 Lo z o Z Z Q w •V — 0 c Lh ITO e � v) � U m C� I••I••I 112 C m cMn _ N U C0 Q rn oio iff W. , z Z 18b' • • A-... W ti Z C9 �7L LLI - LO z W �. N ¢ a ��7 _j To the best of the Engin�et;';.�CnovJ n, ancR belief, the structural plans �id{fs ifications contajr�e4 within these drawings comply wIt' 01W. 6,rCt'i'�' Building Code -Residential 6th Edltlon. Fer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. O Z NO 0 ate) � I>iM00 M Q Ln O (V Ln CL + M oC V a o `. § Z M W J � oZ 2 nQ. �a F- w�aa'� LuLU Fw w S�Z Z 22Ixzw u c1l "o L 00 00 ® z z z r N Ln I.J._ p ULu ( f � a ^ L.V o� a Ql-oz F U0� t� L oLuw Z $gR2 Z J rl Ln rl lJJ LLJ � Z~$ ul o < w � i a m � Z ZUj gz SCALE : AS NOTED DATE : 3/18/2018 TECH: FFLORES VERSION No' 10 SHEET NO. 1.0 r--- --------------------------------------------- I I I ( I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I L- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 22 D1 TYP @ 2 STORY J S6 5 D2 22 D1 29'-6" 29'-0" " 2'-6" 26-6" TYP @ 2 STORY 3 3 D2 D2 OJ 25 SH S6 EGRESS H1 e I I I I I ca 00 I 106 I ca I Co =� 00 N I i � co N 12'-4" co 2' 2' 12'-0" I I I I rn CO c� CARP IT 4 SH 12" DEEP 60 — I W BEDROOM 8'-0" FLAT CLG. LINEN B E D R O M 2 - " FLAT LG. N 2468 B.F. CA PET I i•�cn 7-4- 5'-0" " 4'-2" T-4" 18'-0 8'-8" 2668 2668 I o R &S �^ FIBGLAS — — — — — -- - - - - W. I.C. SURROUND S _j OUND a crm H I, W I il Cr I V-0" FLAT CLG. I 10 11 CARPET 112 ---- O 2668 8--- to — — 1113 14 — 1 15— z -- 46 I I4 G. I M!lf Q\\I 00 7 co 1 N ARPET FLAT CLG. BED OOM 4 1 _ t 6 TB 5-- 3 1— IT \I -- — 1 , _09 �----� �N 2 +42" HALF WALL o w I I H o � d C7 C7 11- O u. 01 0I 8I 4'-0" 3'-4" 5'-10" 3'-10" 12'-0" " CARPET 1 I 8'-0" FLAT CL LOFT N ��" 00 M I 2'-8" 13'4- IT to I I I W I I u- w co m I I oa 0 Go I I I U') CARPET 8' " FLAT CLG. I BE I ROOM 5 25- 3H H2 6 D2 O 3 J 3 D2 Sg D2 TYP @ 2 STORY 6-7" 22'-11" 29'-6" /-Q TYP @ 2 STORY t J H1 D2 4 w O to CV TYP @ CORNERS U.N.O. O_ to HEADER SCHEDULE MARK HEADER SIZE REMARKS H1 (2) - 2X6 #2 SYP W/ 1/2" FLITCH PLATE H2 (2) - 2X8 #2 SYP W/ 1/2" FLITCH PLATE H3 (2) - 2X10 #2 SYP W/ 1/2" FLITCH PLATE H4 (2) - 2X12 #2 SYP W/ 1/2" FLITCH PLATE H5 (2) - 1 3/4" X 11 1/4 LVL 2.0E Fb=2600 PSI H6 (2) -1 3/4" X 9 1/4" LVL 2.0E Fb=2600 PSI H7 (2) -1 3/4" X 16" LVL 2.0E Fb=2600 PSI H8 (2) - 1 3/4" X 7 1/4" LVL 2.0E Fb=2600 PSI (2) - 2X4 #2 SYP W/ 1/2" Follow Q/S4. See Plan for R.A.G. FLITCH PLATE Bearing Wall Call Out When Straps are Required * VERIFY W/ PLAN CORRECT LENGTH OF HEADER REQUIRED ** SEE PLAN FOR DETAIL CALL OUT FOR CONNECTIONS AND REQUIRED STUDS 140C EXTERIOR 2ND FLOOR BEARING WALL SCHEDULE HEIGHT STUD SPECIES SPACING SPF #2 8'-0" 2x4 SYP #2 16" O.C. SPF #2 9'-0" 2x4 SYP #2 16" O.C. SPF #2 >9'-0" 2x6 SYP #2 16" O.C. • IF WITHIN 4FT OF END ZONE, USE DOUBLE STUDS AT CORNERS - WALL SHEATHING 15/32" EXPOSURE 1 OR EQUIVALENT " SEE C/S6 WALL SCHEDULE WINDOW SCHEDULE SIZE R.O. CMU (Flange) R.O. FRAME (Fin) TYPE 12 20X26 184X254 S.H. 13 20X38j 184X37i S.H. 14 20 X 50 j 18 } X 50 S.H. 15 20X63 18JX62j S.H. 16 20 X 72 18 4 X 71 4 S.H. 432 27 1/4 X 26 26 X 25 j S.H. 433 27 1/4 X 38IJ N/A S.H. 434 27 j X 50 j N/A S.H. J 33 N/A 26 x 37 1 S.H. 434 N/A 26 x 50 S.H. J 35 27 j X 63 26 X 62 1/2 S.H. j 36 27 4 X 72 26 X 71 1/2 S.H. 22 37 J X 26 36 4 X 25 1/2 S.H. 23 37 1 X 38 j 36 j X 37 3/4 S.H. 24 37 j X 50 1 36 4 X 50 S.H. 25 37 j X 63 36 } X 62 112 S.H. 26 37 J X 72 36 j X 71 1/2 S.H. DOUBLE 2 WIDE 75" TALL 73 J WIDE S.H. 32 54 X 26 52 } X 25 4 S.H. 33 54 X 38 j 52 j X 37 J S.H. 34 54 X 50 j 52 4 X 50 S.H. 35 54 X 63 52 J X 62 j S.H. 36 54 X 72 52 } X 714 S.H. 39X59 40 X 59 N/A S.H. DOUBLE 39X59 79 X 59 N/A S.H. General notes R302.5 Dwelling/Garage Opening/Penetration Protection. • Openings from a private garage directly into a room used for sleeping purposes shall not be permitted. Door between garage and residence shall be equipped with solid doors not less than 1 3/8" in thickness, solid or honeycomb -core steel doors not less than 1 3/8" thick, or 20-minute fire -rated doors. • Duct Penetration. Ducts in the garage and ducts penetrating the walls or ceilings separating the dwelling from the garage shall be constructed of a minimum No. 26 gage (0.48 mm) sheet steel, 1 inch minimum rigid nonmetallic class 0 or classl duct board, or other approved material and shall have no openings into the garage. • Other penetrations shall be protected as required by section R302.11, Item 4. R302.6 Dwelling/Garage Fire Separation. The garage shall be separated from the dwelling as per the following: • From the Residence & Attics - Not Less than 1/2" Gyp. Bd. or equivalent applied to garage side. • From Habitable Rooms Above Garage - Not Less than 5/8" Type-X Gyp. Bd. or equivalent. • Structure(s) Supporting Floor/Ceiling Assemblies - Not Less than 1/2" Gyp. Bd. or equivalent. • Garages Located Less Than 3 Feet From Dwelling On The Same Lot - Not Less than 1/2" Gyp. Bd. or equivalent applied to the interior side of exterior walls that are within this area. R312.2.1 Window Sills. In dwelling units, where the opening of an operable window is located more than 72 inches above the finished grade or surface below, the lowest part of the clear opening of the window shall be a minimum of 24 inches above the finished floor of the room in which the window is Iocated.Operable sections of windows shall not permit openings that allow a 4-inch-diameter sphere where such openings are located within 24 inches of the finished floor. Chapter 45 Private Swiming Pools, Section R4501.17.1.9 All doors and windows providing direct access from the home to the pool shall be equipped with an exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 db a at 10 feet. Any deactivation switch shall be located at least 54 inches above the threshold of the access. Separate alarms are not required for each door or window if sensors wired to a central alarm sound when contact is broken at any opening. M1507.2 Recirculation of Air. Exhaust air form Bathrooms and toilet rooms shall not be recirculated within a residence or to another dwelling unit and shall be exhausted directly to the outdoors. Exhaust air from bathrooms and toilet rooms shall not discharge into an attic, crawl space or other areas inside the building. GAS APPLIANCES G.C. to verify location of gas riser before commencement of work. see Sht. SN1 for installation detail. Where gas water heaters are installed. Water heaters shall be installed a min. of 18" above fir. per FBCR G2408.2. Except where appliances that are listed as flammable vapor ignition resistant. OPENING PRESSURES ENCLOSED - EXPOSURE "C" CA +29.7 / -30.8 © +29.7 / -39.2 © +28.3 / -30.8 +28.3 / -36.4 OE +26.6 / -28.0 OF +26.6 / -32.2 �G SEE SN SHEET OH SEE SN SHEET 140 MPH NOTE: WIND SPEED INDICATED ABOVE IS AN "ULTIMATE" WIND SPEED. THE WIND PRESSURES LISTED ABOVE ARE ALLOWABLE PRESSURES SOFFIT DESIGN PRESSURE 1 +34.0 / -44.8 WALL LEGEND t♦1111111111111� • - TYP. 2x FRAME WALL BEARING WALL INTERIOR BEARING WALLS NOTED "FLOOR BEARING ONLY" ARE FLOOR SYSTEM SUPPORTING ONLY AND REQUIRES NO UPLIFT CONNECTORS TO FLOOR SYSTEM AREA TABULATION "A1" 1ST FLOOR LIVING AREA 1793 2ND FLOOR LIVING AREA 1103 LIVING TOTAL 2896 GARAGE 437 FRONT ENTRY 26 TOTAL AREA 3359 INSULATION REQ. LOCATION R-VALUE / TYPE EXT CONC WALL R-4.1 HIGH PERM EXT FRAME 2 x 4 R-11/R-13 KRAFT FACED EXT FRAME 2 x 6 R-19 KRAFT FACED CONDITIONED CEILING R-30 BLOWN -IN (INSTALL BAFFELS AT EAVE) GARAGE SEPARATION I R-11/R-13 KRAFT FACED (GARAGE / LIVING) IBz� Q� J a V) C-D � w 0 0 p DU — _( O =o ~ U Mr-- W f— who �' C @ M 04 O L_ _ U t5 - M1�10 Q 0)97 co -6^ u, � UL_ L., U '. z LL To the best of the Eng srp6r's k Igdge, ipfF , aryl belief, the structural plad5AO spe1 A1i&s-tc.ntainesf�'S° within these drawings com*vftg 260`1�7: F,IprZQ��s�' Building Code - Residential 6th rt d 1 l' cr�RQ signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. O Z NO O U N Imo-+U MO „ M Ln Q �'�p Q C- CU � �M Ce U a �00 Z fa W J � 0 �a B u,az, vzOp ?Ww� z S z Z $ w o Q $ L [/mo �/0 N O c�Z 00 z Lr)Lu LL O � Z 4 U = N X 0 a "ce CCg9 bQ�a ZWo Z Z J Ln Ln Lli diu Z �$ N z z = 11z °° O o J c U, ,--i 0- cn SCALE : AS NOTED DATE : 3/18/2018 TECH: FFLORES VERSION NO. 10 SHEET NO. 1.1 4 60 Q MIRROR O M OWNER'S BATH OC cc MIRROR 60 O 9 M KITCHEN ISLAND KITCHEN KITCHEN � SEE PLAN FOR LANDING DEPTH � MIN. (3) 2x STUDS REQ'D @ END OF LANDING BELOW HDR, BEAM. STANDARD (3) 2x12 STRINGERS w/ SIMPSON A35/USP MP34 CLIP TO FLOOR SYSTEM OR LANDING FRAMING (2) 2x HDR. REQ'D @END OF LANDING FOR STRINGERS TO CONNECT TO PLY SHEATHING OVER LANDING ATTACHED PER GENERAL FLOOR CONSTRUCTION NOTES 2x8 #2 SYP JOISTS @LANDING @ 16"O.C. w/ SIMPSON A35/USP MP34 OR LUS26 HANGER ON EA. SIDE MASONRY OR WOOD WALL, SEE PLAN 2x8 #2 SYP (P.T. IF MANSONRY WALL) CONT LEDGER w/ (3) 16d NAILS @ 16" O.C. MAX. TO EA. STUD. ((2) 114"X3 1/2" TITENS @ 16" O.C. MAX. FOR MASONRY WALL) GENERAL LANDING FRAMING INFO. SCALE: N.T.S. 9'-0" MAX LANDING LENGTH O 50 CV 0 STAIR CALCUTIONS: TOTAL RISE = 10'-0 3l4" (16) RISERS AT 7 9/16" 10" TREADS w/ 1" NOSING Stairway construction and handrail to conform to the FBC Residential 6th Edition (2017) section R311.7 Riser height: The maximum riser height shall be 7%'. The greatest riser height within any flight of stairs shall not exceed the smallest by more than Yj". Tread depth. The minimum tread depth shall be 10". The greatest tread depth within any flight of stairs shall not exceed the smallest by more than Nosings. The radius of the nosing shall be no greater that %s'. Solid riser nosings shall not be less than'/." but not more than 1Ya". The greatest nosing projection shall / I not exceed the smallest by more than Yz'. Beveling of nosings shall not exceed J 2x842 SYP JOISTS @LANDING Yz @'16" O.C. w/ SIMPSON A35 CLIP J Handrails. OR LUS26 HANGER TO LEDGER. t" PLYWOOD @ Handrails shall be provided on at least one side of each continuous run of LANDING / U treads or flight with four or more risers. Handrail height, measured vertically / 2x12 HDR. w/ (3) 2x STUDS AT Z from the sloped plane adjoining the tread nosing, or finish surface of ramp / FJ4. END FOR BEARING � slope, shall be not less than 34"and not more than 38". Handrails adjacent to a wall shall have a spac00 e of not less than 1Y2"between the wall and the handrails. b STANDARD (3) 2X12 U STRINGERS W/ SIMPSON A35 � Grip -size. CLIP TO FLOOR SYSTEM u� Handrails with a circular cross section shall have an outside diameter of at 2x8 LEDGER #2 SYP w/ = least 1 1/4" and not greater than 2" or provide equivalent graspavility in (3) 16d NAILS TO STUD compliance with Section R311.7.8.3. @ 16" O.C. 1x RISERS (TYP.) Guards. CONT. Guards shall be located along open -sided walking surfaces, including stairs, HANDRAIL ramps and landings, that are located more than 30"and shall be not less than 36". Required guards shall not have openings from the walking surface to the required guard height which allow passage of a sphere 4" in diameter. Winders. Winder treads shall have a minimum tread depth of 6" at the narrow end and shall have a minimum tread depth of 10" at the intersections with the walkline (12" from the narrower side). R302.7 Under -Stair Protection. Enclosed accessible space under a stairway shall be protected with %' gyp. bd. THRUST BLOCK SECURED TO SLAB w/ 1/4"X3 1/2" TAPCONS @ 16" O.C. INTERIOR ELEVATIONS SCALE: 1 /2"=1'-0" STAIR SECTION SCALE: 1 /2"=1'-0" CD (D Ell CD LLi , bo ce r 10 C9 � z z� a +J W �o O cn � ca U o 0 m �M W M C N M U c �o `1AiF4: CAI 1" x 4" SMOOTH TEXTURED 12 TRIM / BAND 5� 6" FASCIA (TYP) T.O.P. HDR HGT. N r` M. F7 8'-0" RIDGE VENT 12 �5 COMPOSITION SHINGLES ROOF INSTALLED AS PER MANUF. SPECIFICATIONS 1" x 12" SMOOTH 25 SH 12 , ^ , 25 SH 25 SH TEXTURED 5� --- FLASHING TRIM / BAND 2nd FIN. FLR. -----— — — — — — — — — — — — — — — — — — — — — — — — ----------------------------— — — — — — — ------------------------- — — — — — T.O.M. HDR HGT. _ _ _ _ DECO CORBEL F16 TEXTURED ~ CEMENTICIOUS FINISH ON C.M.U. 25 SH F.FL. 12 5L,--' 1 4' RIDGE VENT 12' RIDGE VENT 12 5� 1 1'-21" 4 FRONT ELEVATION - Al ------T.O.P. HDR HGT. �I r -011 N tl- 25 SH CJ 2nd FIN. FLR, --- -------------------------------------------------------- CJ / WEEP —---------------------------------------------------------------------------------------------- -----HDR HGT. 2'-0" TEXTURED - CEMENTICIOUS FINISH ON C.M.U. 25 SH (NP•) -------------------------------------------------------------------------------------------------------------------- — —-----F.FL. —NCO co SCALE: 1 /4"=1'-0" LEFT ELEVATION - Al 1 /4"=1'-0" General Notes ROOF CRITERIA: • 12" OVERHANG U.N.O. 0 PLUMB CUT FASCIA ROOF • PITCH PER ELEVATION **G.C. VERIFY ROOF PITCH** ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE CONTRACTORS RESPONSIBILITY TO VERIFY ROOF SLOPE REQUIREMENTS WITH TRUSS MANUFACTURER. **ELECTRICAL SPECIFICATION NOTES** ELECTRICAL CONTRACTOR MUST VERIFY WITH THE SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT FIXTURES SHOWN ARE FOR LOCATION PURPOSES. Exterior Covering R703.7 Exterior plaster. Installation of these materials shall be in compliance with ASTM C 926 and ASTM C 1063. R703.7.1 Lath. All Lath and lath attachments shall be of corrosion -resistant materials. Attached per ASTM C 1063. R703.7.2 Plaster. Plastering w/ portland cement plaster shall be not less than three coats when applied over metal lath or wire lath and shall be not less than two coats when applied over masonry, concrete. R703.7.3 Water-Resisitive Barriers. Water-resisitive barriers shall be installed where cement plaster (stucco) is to be applied over wood -based sheathing, shall include a water -resistive vapor -permeable barrier. The individual layers shall be installed independently such that each layer provides a separate continuous plane and any flashing intended to drain to the water -resistive barrier is directed between the layers. The barriers shall consist of one of the following. 1. Two layers of an approved water resistant barrier material in accordance with R703.2. 2. One layer of an approved water -resistive barrier (paperbacked stucco lath) over an approved synthetic house wrap. R703.4 Flashing. Approved corrosion -resistant flashing shall be applied shingle -fashion in a manner to prevent entry of water into the wall cavity or penetration of water to the building structural framing components. Flashing shall be installed at the following locations. • Exterior window/door openings. • Intersection of chimneys or other masonry contructions with frame walls. • Under and at the ends of masonry, wood or metal copings and sills. • Continuously above all projecting wood trim. • Where exterior porches, decks or stairs attach to a wall or floor assembly of wood -frame construction. • At wall and roof intersections • At Built-in gutters. Attic Ventilation Attic Ventilation to be in compliance with the Florida Building Code 6th Edition (2017) Residential R806. The Minimum net free ventilating area shall be 1/150 of the area of the vented space. The ventilating area may be reduced to 1/300 provided that at least 40% but no more than 50% of the required ventilation is provided in the upper portion of the space to be vemilated.Upper ventilators shall be located no more than 3 feet (measured vertically) below the ridge or highest point of the space, with the balance of the required ventilation provided by eave or cornice vents. "CALCULATIONS BASED ON THE FOLLOWING VALUES, SEE ROOF PLAN" (Values to be verified with Manufacturer Specifications) • RIDGE VENTS 15 SQ. IN. OF NET FREE AREA / LINEAR FT. • OFF -RIDGE VENTS 138 SO. IN. OF NET FREE AREA / UNIT • SOFFIT VENTS 7 SQ. IN. OF NET FREE AREA / SO. FT. �Ln C_ z� z� a cn 4--J W �6 0 �V — O LU E _01 U �ZD —m �� W ® ~ M C .- M O O N U� Way � ¢o, �<Ci 0o i0 CVa _ , M N *ice _J ���"00 p� .•l•7(gyp o' • ' m a' I' o Cy sN .,.' O To the best of ng neer's knbNiedge lnforn, belief, the struct Ian S�n„��specific�,tiQr� Qritair�S• within these drawi�f 'corn .1 w1t 1 t JO'll Flori##s• Building Code - ResidenFtytJ� Edition. En pglc` signature and seal is only t�dr A I iJ • 1 6� gineering portions of the drawing pages bearing ngineer's signature and seal. O z� 0to ate+ I>Lnto M Q 'gyp Ln i1 N•L� zzoC N A In C LL U a M-I Q � Z WJ CD €OZ 3� u Q=Qa F� U) Z Im g O ccU azi g g pJ 8W�s O��Z® M W`J {yo: �— 00 W N J w }o z oV) 3: a Lr) U) V C: Z Lu = Q o ~ . z PRE w0-C 0 f-4 c L.L. o< ��� Z t-•I �aLu _J Ln LijZV �a N Q Z W ~ C) 2 f V Z �jVaz m oo Q � _ SCALE : AS NOTED DATE : 3/18/2018 TECH: FFLORES VERSION NO. 10 SHEET NO. 3.1 0 T.O.P. HDR HGT. _ 2nd FIN. FLR. T.O.M. _ F.FL. _ 8'-0" RIDGE VENT 12 5� 12 zz::::�5 COMPOSITION SHINGLES ROOF INSTALLED AS PER MANUF. SPECIFICATIONS ---------------------------------------------- E--------- ------------------ EXTENDED OVERHANG TO BE CENTERED ON TEXTURED DOOR CEMENTICIOUS FINISH ON C.M.U. 25 SH (NP') 25 SH 25 SH 12' RIDGE VENT ---------------- F.FL. —loo P c0 IN REAR ELEVATION - Al SCALE: 1 /4"=1'-0" RIGHT ELEVATION - Al : 1 /4"=1'-0" General Notes ROOF CRITERIA: • 12" OVERHANG U.N.O. • PLUMB CUT FASCIA ROOF • PITCH PER ELEVATION **G.C. VERIFY ROOF PITCH** ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE CONTRACTORS RESPONSIBILITY TO VERIFY ROOF SLOPE REQUIREMENTS WITH TRUSS MANUFACTURER. **ELECTRICAL SPECIFICATION NOTES** ELECTRICAL CONTRACTOR MUST VERIFY WITH THE SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT FIXTURES SHOWN ARE FOR LOCATION PURPOSES. Exterior Covering R703.7 Exterior plaster. Installation of these materials shall be in compliance with ASTM C 926 and ASTM C 1063. R703.7.1 Lath. All Lath and lath attachments shall be of corrosion -resistant materials. Attached per ASTM C 1063. R703.7.2 Plaster. Plastering w/ portland cement plaster shall be not less than three coats when applied over metal lath or wire lath and shall be not less than two coats when applied over masonry, concrete. R703.7.3 Water-Resisitive Barriers. Water-resisitive barriers shall be installed where cement plaster (stucco) is to be applied over wood -based sheathing, shall include a water -resistive vapor -permeable barrier. The individual layers shall be installed independently such that each layer provides a separate continuous plane and any flashing intended to drain to the water -resistive barrier is directed between the layers. The barriers shall consist of one of the following. 1. Two layers of an approved water resistant barrier material in accordance with R703.2. 2. One layer of an approved water -resistive barrier (paperbacked stucco lath) over an approved synthetic house wrap. R703.4 Flashing. Approved corrosion -resistant flashing shall be applied shingle -fashion in a manner to prevent entry of water into the wall cavity or penetration of water to the building structural framing components. Flashing shall be installed at the following locations. • Exterior window/door openings. • Intersection of chimneys or other masonry contructions with frame walls. • Under and at the ends of masonry, wood or metal copings and sills. • Continuously above all projecting wood trim. • Where exterior porches, decks or stairs attach to a wall or floor assembly of wood -frame construction. • At wall and roof intersections • At Built-in gutters. Attic Ventilation Attic Ventilation to be in compliance with the Florida Building Code 6th Edition (2017) Residential R806. The Minimum net free ventilating area shall be 1/150 of the area of the vented space. The ventilating area may be reduced to 1/300 provided that at least 40% but no more than 50% of the required ventilation is provided in the upper portion of the space to be ventilated.Upper ventilators shall be located no more than 3 feet (measured vertically) below the ridge or highest point of the space, with the balance of the required ventilation provided by eave or cornice vents. "CALCULATIONS BASED ON THE FOLLOWING VALUES, SEE ROOF PLAN - (Values to be verified with Manufacturer Specifications) • RIDGE VENTS 15 SQ. IN. OF NET FREE AREA / LINEAR FT. • OFF -RIDGE VENTS 138 SQ. IN. OF NET FREE AREA / UNIT • SOFFIT VENTS 7 SO. IN. OF NET FREE AREA / SO. FT. as cD !9 ZC> z�z a 4--J w f>3 p w Oc h' I-- m ~ U W ■ ~ �� C t0 c" ON o C) 11-00 o ¢ rn LO 01 Q o Al I D D• NC - 11`W 0 9Az J ' fW kC� F �; Z G � UM z•. C, W To the best of the Ei .ipfortrlatio�Td belief, the structural and c'ifications c t& within these drawings c wit a BuildingCode - Residentia En ineer's ition. ` `off signature and seal is only, fort 99FdRtr4=0-�� portions of the drawing pages bear ng E Af er s signature and seal. O z N 0 > V) M O M Q 'fU In Ifl ccnn a LL �' '� a .-. F-3-000 a 00 E z WJ CD J R WE Z a fa U) ~ W O J 0*1 W� ��® W00 g L OO W p a 8 z R N o cu Lr) U) 0 O = � QLu f w c`iowZd k Q N I� Cr 5�6� g fg z ^ u _R u J r�-i NJ W o lJ.l � z Z U N Q as m � N 0o z g LIJ = W ,•-t a cn SCALE : AS NOTED DATE : 3/18/2018 TECH: FFLORES VERSION NO. 10 SHEET NO. 3.2 2" 2" N 00 io 1' *NOTE: VARIES FOAM TO BE USED ONLY WHEN _ 3„ REQUIRED BY COMMUNITY SPECS. IF NOT, 1" OPENING VARIES DETAIL TO BE 2„ IEEDGE BUILT W/ STUCCO. OF OPENING --� • • 10" 24' T i a e s N M o� r I 1-1/2" THICK cc CV � fV I I 00 I I i I VARIES 0o *NOTE: FOAM TO BE USED ONLY WHEN = REQUIRED BY t` COMMUNITY SPECS. IF NOT, DETAIL TO BE 1 BUILT W/ STUCCO. VARIES OPENING VARIES 2" EDGE OF OPENING 10" 6" _ N r 6" ::4 2„ N NOTE: • FIN. TO HAVE TRADITIONAL LOOK & SMOOTH FINISH • FOAM/ EPS MATERIAL IS ACCEPTED T-8" R7p„ CAP r CAP 1" RADIUS CO 3 1/2" RADIUS 1/2" RADIUS iv 3/4" RADIUS a 1'-5a" 4 A. M,a 1" 1" 1/2" RADIUS 1" 1" 1" 4" VARIES VARIES 1'-4„ VARIES 12' VARIES AN 1" 11 1 1/2" RADIUS 2 1/2" RADIUS � f0 32" 11" 32" 1" 1" 1" BASE BASE 1'-8" CO T V-6" 1" 24" • T i 1-1/2" THICK 1-1/2" THICK (V W W 7„ 4„ C y VARIES VARIES (2-1" VARIES VARIES i 6" 4" KEYSTONE F11 0 - KEYSTONE F11 OPTIONAL OPTIONAL 4"CV CV � 'v RoarT" v GARAGE DR. OPENING 4" 3 a 4" WINDOW OPENING 2' NOTE: • INSTALL OVER STONE, TYP. • FIN. TO HAVE TRADITIONAL LOOK & SMOOTH FINISH • FOAM/ EPS MATERIAL IS ACCEPTED 2'-1 " 1 �-4„ 14" 1 _64„ 14„ 12„ 121 1" GENERAL NOTES: • 1.5 LBS DENSITY STYROFOAM • POLYCOAT (HARD COAT) • ACRYLIC SAND FINISH U z z N Z QQQ Q n 0 V) (D cn M 0 •U — O LU .0 E U m M w ' +� M ,R -1,N _ U- o 0 gipp. o Q C) Q O B D. x T -X _o c�pp O C M Z� m Z Z W d M W L.L- 8 M .--1 A/ Ir � li N a 0 W L.L •U N 01 W z Q Z Q is �i�5 m m traEorw d LL�¢ W To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the 2017 Florida Building Code - Residential 6th Edition. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. 0 Z (V O a) r-, 1-4 4-Jo Lnro M Q U-) 'p Ln Ln Q U fl tM V Q00 a E" WLU Z J �z W� zaa fa F C�z�o i�OWU gQ -Z J U0'f� �CC-8 00 W �® �8 M w C 1 U N L 0 ,� 0 U = cr: 9f >�a R J ; ; J �Uy N ga�S¢ aaujo Z J Ln .. LJJ a 0 W Q NU M N Z z 1�z 9 m 1 06 � yrj LLJ = z � o dz uj SCALE : AS NOTED DATE : 3/18/2018 TECH: FFLORES VERSION NO, 10 SHEET NO. F 1 ELECTRICAL SPECIFICATION NOTES: ELECTRICAL CONTRACTOR MUST VERIFY WITH THE SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT FIXTURES SHOWN ARE FOR LOCATION PURPOSES. 200A INDOOR PANEL CENTER #14 copper to lights 8 outlets HEMA 1 200 AMP 01 #12 copper to 20 amp ckts 10 #10-2 copperto WH 10 #10-3 copper to Dryer METER MAIN O 2/0 or 4/0 SER Alu 200 amp 150 amp POWER CO. FEED INTERSYSTEM BONDING TERMINATION PER NEC 14, 250.94 4 Bare Cu Ground CLAMP PER 250.50 AND 250.52 OF THE 2014 NEC. GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. 1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF (general) kitchen 44" AFF bathroom 39" AFF laundry room 36" AFF exterior waterproof 12" AFF garage general purpose 42" AFF range 2" AFF 2. All trim plates & devices to be ganged, where possible. 3. Electrical switches to be at 42" centerline above finished floor. 4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the installation & sizing of all electrical, wiring & accessories. 5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. 6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. 7. Provide Tamper Resistant Receptacles as required by the 2014 NEC, 406.11 8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and vapor detector sensor, according to the installation. 9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a Nationally Recognized Testing Laboratory. 10. Keep all smoke detectors minimum of 36" from bathroom doors 11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be equipped with a monitored battery backup. 12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits is not acceptable. 13. All doors and windows providing direct access from the home to the pool shall be equipped with an exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning when the door or window are opened.. 14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' if the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacles outlests shall not be required on a wall directly behind a range or sink to fulfill the requirement for an outlet every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and 18" for sinks and ranges installed in corner counters. ELECTRICAL KEY DUPLEX CONVENIENCE OUTLET DUPLEX OUTLET ABOVE COUNTER W.P. WEATHERPROOF DUPLEX OUTLET GROUND FAULT INTERRUPTER DUPLEX OUTLET G.F.I. I HALF -SWITCHED DUPLEX OUTLET I Ph SPECIAL PURPOSE OUTLET VIM DUPLEX OUTLET IN FLOOR 220 VOLT OUTLET $ WALL SWITCH $3 THREE-WAY SWITCH 24 FOUR-WAY SWITCH R RHEOSTAT SWITCH CEILING MOUNTED LIGHT FIXTURE LED LED CEILING MOUNTED LIGHT FIXTURE WALL MOUNTED LIGHT FIXTURE ORECESSED LIGHT FIXTURE P.C. LIGHT FIXTURE WITH PULL CHAIN TRACK LIGHT FLOURESCENT LIGHT FIXTURE O EXHAUST FAN EXHAUST FAN/LIGHT COMBINATION ELECTRIC DOOR OPERATOR (OPTIONAL) CH CHIMES (OPTIONAL) El PUSHBUTTON SWITCH (OPTIONAL) SD SMOKE DETECTOR CM SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) TELEPHONE (OPTIONAL) © TELEVISION (OPTIONAL) Tq 2 (2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. O THERMOSTAT D9 ELECTRIC METER ffin ELECTRIC PANEL DISCONNECT SWITCH ® SPEAKER (OPTIONAL) �7 ROUGH -IN FOR OPT. CEILING FAN v J c� CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR G J OPT. CEILING FAN 613 (1) PHONE LINE, (1) DATA PORT RECEPT. FOR ALARM SYSTEM VERIFY METER LOCATION WITH BUILDER H (I� i U �� IRRIGATION VP j'---- (� ---, VERIFY LOCATION I GFI @ 44" A.F.F. , n'. I. C. i W H ELECTRICAL PANEL V V l� I O 00, I I I ' \\ -- — OWNER S SUITE 2 CAR GARAGE 1 I I ROUGH -IN FOR OPT. CLG. FAN/ I \T-1-77 j GARAGE GFI FOR GAR. DOOR 1 LIGHT PRE -WIRE _ I LIGHT AS PREWIRE i I PER SPECS I GFI @ 44" 1 G-----------J A.F.F. T02_N_D �\ \ OPt. D GFI@4411 - / A.F.F. L------------ S.D C.M -- -- - - / GFI @ 44"WP O / 1 1 1j ----- 16 - - - - A.F.F. GFI ------- 3 ' CH - - - - - 11 3 PATIO I C.M I DEDICATED RECEPTACLE / FOR MICROWAVE RANGE j I HOOD PER SPECS / U.C. SWITCH FI FOR DISPOSAL ..... If i. t, \ FAMILY RM / / CAFE GFI,; 1 - / FLEX I C I G �/ PENDANT AS jl D.W. I \ ROUGH -IN FOR I I II19 OPT. CLG. FAN/ PER SPECS \ C _ �— J I PANTRY \ `! . ;C I LIGHT PRE -WIRE / \ WP VGFII -- G J GFI =0 / - - 4 1 / oo \� — ROUGH -IN FOR 00 OPT. CLG. FAN/ DISC. 4 1 / / \ LIGHT PRE -WIRE - / OPT. REF. AC PAD AC PAD --- GFI - ------ ----GFIdb WP I GFI I GHTIAS jGFI J ENTRY MAIN FLOOR ELECTRICAL PLAN SCALE: %4'=V-0" 0 _: � N z QQQ Q a W W � 4--J ly Q DU — -( O c .12 e In U U o m CN CN L.L ' ~ dM C Cn tD 2 O O N U L LL 00 AYE 0 Q l7l O� O ro N Z y o z LL Z H N �� Ci- W — of C u W Q D�� d z _ 4¢ �� M� 6 o 0 m coZ Z LL W Na a M 0 O O U ❑❑ To the best of the Engineer's knowledge, Information, and belief, the structural plans and specifications contained within these drawings comply with the 2017 Florida Building Code - Residential 5th Edition. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. O Z N O � N CD u>-+HMO fM Q�'p170 o- to •L, d- QLL Z � v fa CL 00 Q Z E -0 W J � 1 Z .1 Z Qa f� F- Z wa�� O ce U z U, (71 U w o LWL u. WM "gu W Z � N I— Z 0 w Lr) J LJJ c U _ i O �uj (� O J ILL oI ILpo o a AYp za a3 Z .--1 0 � U. LL a� J Ln LJ.I Z UJI Q a l Z U w�� M N N Q Z Z �IS 90 m � 00 � U 2 9 ,--i a V) SCALE : AS NOTED DATE : 3/30/2018 TECH: MJAMES VERSION N0. 10 SHEET NO. 4.0 ELECTRICAL SPECIFICATION NOTES: ELECTRICAL CONTRACTOR MUST VERIFY WITH THE SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT FIXTURES SHOWN ARE FOR LOCATION PURPOSES. GENERAL ELECTRICAL NOTES: Notes: unless otherwise noted, 1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF (general) kitchen 44" AFF bathroom 39" AFF laundry room 36" AFF exterior waterproof 12"AFF garage general purpose 42" AFF range 2" AFF 2. All trim plates & devices to be ganged, where possible. 3. Electrical switches to be at 42" centerline above finished floor. 4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the installation & sizing of all electrical, wiring & accessories. 5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. 6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. 7. Provide Tamper Resistant Receptacles as required by the 2014 NEC, 406.11 8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and vapor detector sensor, according to the installation. 9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a Nationally Recognized Testing Laboratory. 10. Keep all smoke detectors minimum of 36" from bathroom doors 11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be equipped with a monitored battery backup. 12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits is not acceptable. 13. All doors and windows providing direct access from the home to the pool shall be equipped with an exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning when the door or window are opened.. 14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' if the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacles outlests shall not be required on a wall directly behind a range or sink to fulfill the requirement for an outlet every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and 18" for sinks and ranges installed in corner counters. ELECTRICAL KEY DUPLEX CONVENIENCE OUTLET FfF DUPLEX OUTLET ABOVE COUNTER W.P. WEATHERPROOF DUPLEX OUTLET G.F.I. GROUND FAULT INTERRUPTER DUPLEX OUTLET HALF -SWITCHED DUPLEX OUTLET SPECIAL PURPOSE OUTLET DUPLEX OUTLET IN FLOOR 220 VOLT OUTLET WALL SWITCH $3 THREE-WAY SWITCH �4 FOUR-WAY SWITCH $R RHEOSTAT SWITCH CEILING MOUNTED LIGHT FIXTURE LED LED CEILING MOUNTED LIGHT FIXTURE WALL MOUNTED LIGHT FIXTURE ORECESSED LIGHT FIXTURE P.C. LIGHT FIXTURE WITH PULL CHAIN TRACK LIGHT —� FLOURESCENT LIGHT FIXTURE O EXHAUST FAN ;Q1 EXHAUST FAN/LIGHT COMBINATION ®D ELECTRIC DOOR OPERATOR (OPTIONAL) CH CHIMES (OPTIONAL) El PUSHBUTTON SWITCH (OPTIONAL) SD SMOKE DETECTOR CM SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) TELEPHONE (OPTIONAL) ® TELEVISION (OPTIONAL) © 2 (2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. O THERMOSTAT ELECTRIC METER Awl ELECTRIC PANEL _RR__j DISCONNECT SWITCH (gj SPEAKER (OPTIONAL) �7 ROUGH -IN FOR OPT. CEILING FAN V J CEILING MOUNTED LIGHT FIXTURE W/ROUGH-IN FOR 17K, L J OPT. CEILING FAN 99 (1) PHONE LINE, (1) DATA PORT 200A INDOOR PANEL #14 copper to lights & outlets t #12 copper 200 to 20 amp ckts 00 AMP #1D-2 copper to WH #10-3 copper to Dryer n 2/0 or 4/0 SER Alu 200 amp 150 amp Disconnect POWER CO. FEED INTERSYSTEM 4 Bare Cu Ground BONDING #4 GROUNDING WIRE TERMINATION PER WITH CODE APPROVED NEC 14, 250.94 CLAMP PER 250.50 AND 250.52 OF THE 2014 NEC. Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. r— — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I L----------------------------------------------------- I I I I I I I I I I I I I I I UPPER FLOOR ELECTRICAL PLAN SCALE: %4'=1'-0" U z o CD z� z Q U) z CZ V), C D W r/> 4-J w U c L) E �Ln ~ U C^ m aM _ — ~ E p � 0CN 0 O O _ eU' U rah LL � to ¢m �o 6 C � � N CD con Z O D LL. J of R C" L. '0 d �Z 0��'°' E mm .� � � w St � W 04 o O U U F ❑❑ To the best of the Engineer's knowledge, information, and belief, the structural plans and specifications contained within these drawings comply with the 2017 Florida Building Code - Residential 6th Edition. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. 0 0 Z N O�I� ►>Lr)M0 M Q Ln M LA a to •0 It Q LL oCV 00 Q C Z� ca W d' �z W za f¢ F �zao �03,� z� z �z Q 0 g m v Uo ® L N W �Z Uj J yr 3 Ln W C 0 w U _ O LLJ 89. J ILL. �jRo I Q V- N I Z Z •--I LL1 0. of =L�j a c `` _LLJ Q ZLLI Zo N *k N z t- 9 m O 00 g = a W rn .--+ a I U) SCALE : AS NOTED DATE : 3/30/2018 TECH: MJAM ES VERSION NO- 10 SHEET NO. 4.1 ATTIC VENTILATION CALCULATIONS - Al ATTIC VENTILATION REQUIRED UPPER VENTILATION PROVIDED 1/150 Rule 1/300 Rule Ridge Off -Ridge (No Upper Ventilators (Must Provide Upper Ventilators) Vent Amt Amt. Req.) (Ft.) Total Ventilation ATTIC Provided SPACE SQ. FT. Total SQ. SQ. FT. SQ. IN. of by Upper SQ. IN. of of vented IN. of of ventilation to SQ. IN. of SQ. IN. of Ventilators ventilation soffit ventilation vented be provided Ventilation (See SElev) required q needed required soffit yupperVentilation needed ventilators Main 4.000000 2.000000 Floor 1080 1037 148 518 37 259 336.0 60.0 276.0 (Zone 1) Main 0.0 0.000000 Floor 16 15 2 8 1 4 0.0 0.0 (Zone 2) 0.0 Upper 16.000000 0.000000 Floor 1166 1119 160 560 40 280 240.0 (Zone 3) 240.0 0.0 *NOTE" GENERAL CONTRACTOR MUST ENSURE THAT PROPER VENTILATION IS PROVIDED AT EAVES/SOFFITS AS REQUIRED BY FBC 6th ED. RESIDENTIAL. ROOF PLAN SCALE: 14"=V-0" General Notes ROOF CRITERIA: • 12" OVERHANG U.N.O. • PLUMB CUT FASCIA ROOF • PITCH PER ELEVATION **G.C. VERIFY ROOF PITCH** ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE CONTRACTORS RESPONSIBILITY TO VERIFY ROOF SLOPE REQUIREMENTS WITH TRUSS MANUFACTURER. **ELECTRICAL SPECIFICATION NOTES** ELECTRICAL CONTRACTOR MUST VERIFY WITH THE SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT FIXTURES SHOWN ARE FOR LOCATION PURPOSES. Exterior Covering R703.7 Exterior plaster. Installation of these materials shall be in compliance with ASTM C 926 and ASTM C 1063. R703.7.1 Lath. All Lath and lath attachments shall be of corrosion -resistant materials. Attached per ASTM C 1063. R703.7.2 Plaster. Plastering w/ portland cement plaster shall be not less than three coats when applied over metal lath or wire lath and shall be not less than two coats when applied over masonry, concrete. R703.7.3 Water-Resisitive Barriers. Water-resisitive barriers shall be installed where cement plaster (stucco) is to be applied over wood -based sheathing, shall include a water -resistive vapor -permeable barrier. The individual layers shall be installed independently such that each layer provides a separate continuous plane and any flashing intended to drain to the water -resistive barrier is directed between the layers. The barriers shall consist of one of the following. 1. Two layers of an approved water resistant barrier material in accordance with R703.2. 2. One layer of an approved water -resistive barrier (paperbacked stucco lath) over an approved synthetic house wrap. R703.4 Flashing. Approved corrosion -resistant flashing shall be applied shingle -fashion in a manner to prevent entry of water into the wall cavity or penetration of water to the building structural framing components. Flashing shall be installed at the following locations. • Exterior window/door openings. • Intersection of chimneys or other masonry contructions with frame walls. • Under and at the ends of masonry, wood or metal copings and sills. • Continuously above all projecting wood trim. • Where exterior porches, decks or stairs attach to a wall or floor assembly of wood -frame construction. • At wall and roof intersections • At Built-in gutters. Attic Ventilation Attic Ventilation to be in compliance with the Florida Building Code 6th Edition (2017) Residential R806. The Minimum net free ventilating area shall be 1/150 of the area of the vented space. The ventilating area may be reduced to 1/300 provided that at least 40% but no more than 50% of the required ventilation is provided in the upper portion of the space to be ventilated. Upper ventilators shall be located no more than 3 feet (measured vertically) below the ridge or highest point of the space, with the balance of the required ventilation provided by eave or cornice vents. -CALCULATIONS BASED ON THE FOLLOWING VALUES, SEE ROOF PLAN - (Values to be verified with Manufacturer Specifications) • RIDGE VENTS 15 SQ. IN. OF NET FREE AREA / LINEAR FT. • OFF -RIDGE VENTS 138 SO. IN, OF NET FREE AREA / UNIT • SOFFIT VENTS 7 SO. IN. OF NET FREE AREA! SQ. FT. u, z� z� <C a z V^)' 0 � w O c =3o E U CIA co tJJ M C f0 fM U ao 0.2 ) Q co � G B D• co ul ow a v S Q inz � 11Lu.� El� a � W 0 01 To the best of the E gyK er's k I¢d& ati d belief, the structural plat,i," ��sppeclfications cq d within these drawings comply hllfphelqN�}rtla Building Code - Residential 6th Edd o7 gineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. 1t 0 Z N 0 N n P-44-'p Ili M O z M Q 'gyp Ln a cn •L �• 0 In v LIL z M U 00 ao zCY � W Z � J � J oZ za �a F- Lu Z, QQ� OVCFW� W M�M W OZ lz o U Z vi 3 ^ �.., / 0 Q a U = ___I LU f 89 J O O � a�a O Z $fig o�Z J --ILLJ W Q Z a u- 8 Z U LUZ N ON ZZ LU m N 4Z T� rn J i W ,-4 a cn z SCALE : AS NOTED DATE : 3/18/2018 TECH: FFLORES VERSION NO. 10 SHEET NO. 5.0 j'. Y 1, 6-68' '4 TYP @ 1 S3 STORY FOOTIV%. - 2'-6" x 2'-6" x V-0" W/ (3) #5's E.W. J TYP @ 2 S6 STORY 6'.4" 41 3'-O" H.B.+ 0 ■ ■ ■ ■ ■ • • • • • • . • • • , • . • . ••4— ■ ■ ■ ■ LIF I ---- --j-: r O (2) #5 REBAR I ih I I } O VERTICALS w/ in 0._0 I ; ; I : FILLED CELL ■ ' 15-71" 6-34„ = ( 121'-2"' I� 2 STORY 1 = I (: pQ I M o 1 K m I 15'-600 4" T 1. 4--`4a" S3 Ci ( to to `1 N I TYP @ 1 : STORY I I I — — — } O '�—T UOPT. -W co A { I : -3 1/2" SLOPE S3 INDICATES FILLED CELL w/ 3000 PSI �? I { o) : I I • • I CONC. GROUT FROM FT. TO BEAM W/ iv { j i:( ; (1) #5 REBAR VERT ABOVE SLAB TYP I ALL PLACES SHOWN D FTG } o@ I} OPT. DI DOWELS EEMBED VV25' EXT. I ABOVE SLAB "GRADE 40 STEEL" :: ; : ; ; : : I 00 I I G I 2 STORY CC (2) #5 REBAR T G ( I S3 VERTICALS w/ in o M I S3 I = I FILLED CELL - —CJ —CJ --- -- -- ------ J ■ o CD 2'-6" x 2'-6" x V-0" I PROVI DE Y2' x 9" 2'-6" x 2'-6" x 1'-0" — — — L I 27'-24" I W/ (3}7tf E.W. RECESS FOR FRT. DOOR I 19'-22' 2'-0" 2'-d W/ (3) #5's E.W. (TYP. OF 2) 0 o I S3 I I SOPE, r3L1 (V F- N 80 co 1O I -31/2'. 1 Y2" RECESS 10'-42" Z-34" 3'-4" I 9'_9$" /2" S3 ( PROVIDE I FOR SGD. REFER TO I � 0'-0'• I KITCHE ISLAND LOW ...... TOP OF CONC./ PAVER TO BE 4' BELOW FIN. FLR. ; ■ ; — — — MASON'S SLOPE FOR — — — — — — ------ — ■ ■ WIDTH I WALLS F 1,57 = __a-- I I I --- -- -----� ---� CHASE TO _ • I N ` • . ■Cal STEPS AS I I I I — _ _ r STUB UP TO L = REQUIRED PER FIELD CONDITIONS I I 1 III 1 a ISLAND _ , _ _ ; _ ; _ I i o f AHU _ : I 1 Fol — ; ; 2ND FLOOR : ' • FOR A/C T , a 4'-0" I CJ CJ IA WT I Z I CJ CJ I _ —I _ IF- — — � io I II I III 111 D.W.11� 11 ■ - HVAC CHASE I BASED ON 3-1/2" MIN 3000 PSI CONC. SLAB FOR I III L�— — LL _ J I . , i ivco 0'-0 " , co M I LOCATION I HERNANDO COUNTY ONLY 3-1/2" MIN 2500 PSI CONC SLAB OVER 6 = :: r —; MIL VISQUEEN VAPOR BARRIER I ``) �HVACCHASE I I 0 0 BASED ON LOCATION ---- ;; ----- -- :: —-------- I ;■ i , ■................... ........... 4.1........... :» »■. .... ... .:... :.................■ A TYP @ 1 f2'-6" x 2'-6" x 1'-0" 3'-0" 83 STORY W/ (3) #5's E.W. 4'-11" 2'-22" 2'-51" 4'-6" 4'-8" 3'-10" 4'-5" 4,-8" 27-0" 1-STORY . 2-STORY , FOOTING F06113A60" J TYP @ 2 S6 STORY 6'-0" 29'.0" -0" 6'-4" FOUNDATION PLAN NOTE: • WHERE PROJECT IS TO BE LOCATED IN KNOWN RADON GAS PREVALENT AREAS, APPENDIX "E" OF THE FBC 6th EDITION (2017) BUILDING IS TO BE IMPLEMENTED. CONCRETE STRENGTH IN THESE AREAS TO BE A MINIMUM OF 3000 P.S.I. THEREFORE, ANY AND ALL NOTES ON THESE PLANS THAT INDICATED 2500 P.S.I. SHALL BE REPLACED WITH 3000 P.S.I. FOR THE CONCRETE STRENGTH • SEE SHEET SN FOR SOIL & TERMITE NOTES. BORATE / BORACARE TREATED LUMBER IS AN ALTERNATE TERMITE PROTECTION TO SOIL POISONING W.W.M. PLACED IN 1/8" SAWCUT x 114 SLAB UPPER 1/3 OF SLAB THICKNESS WHERE OR FIBERMESH SHOWN ON REINF. SEE PLAN. FOUNDATION PLAN LF . LLI w C13 a CONTROL JOINT DETAIL SCALE: 1112"=14" .;� • .. �' ;;: #5 CONT REINF. SEE .: • �. FND. FOR QUANTITY �: ;: "•.,; ' ' :r #5 X 25" X 25" CORNER ' �'• ' •'• ' ' �' '• �'' BAR ONE FOR EA. ' ;. HORIZ. REBAR, TYP. • •17 U.N.O. • • • •, --Alternate: ' The reinf. bars shall be • •, • •, • Cont. around corner by cold bending the bar w/ min. bar lap of 25". TYP. CORNER BAR DTL. SCALE: 1 1 /2"= V-01" C9 Z o Z Z Q a U) z cn +..i w 0 c ZZ) E zruV) U m a 01 M — W®~E M .2M O O N _ t` m C rn LO �iQ d B D• NN _v 1-'Q „1 � o �• t�t r r `�� ICY` `, ,0 �•' Q A, LL l� I� To the best of the Englnee'9 knowledge, 1pfgr� 'n, belief, the structural plans and spbL1fL&Rdhs'c6ntainq within these drawings colYflSty yyith the 2017 F)Rr Building Code -Residential 6thppt6PAbl'¢'br's signature and seal is only for the stru tural engineering portions of the drawing pages bearing Engineer's signature and seal. 1< O O Z cV 0 c n �>-t�Mp M a�M`" a. vcni��n L- LL a .-. z cC V CL 0 Q E Z W J p d" J W � �a Z 5480, z z V • W h z ��� 00 0 g� M 00 ¢ ro ' I1) =5 0 o = 0 o a Vogg a z r� WW W LU �0� ��-1 I W M z �y a 0)Z �Z. fag m O N 0o Z g w = w rn ,-a 0- cn f SCALE : AS NOTED DATE : 3/18/2018 TECH: FFLORES VERSION NO. 10 SHEET NO. 6.0 ro J TYP @ 2 STORY S6 FTF7 I FTF1 04 ILL .... J 04 04 LL M D2 — — — — — — — — — — — 14 ---- - 15---- --- —_ t 16 -- FT8G X 10, U. �. H - ILL.LL ULL . .. 1❑ . ... .... . FTF1 . J TYP @ 2 STORY A S6 L L L � 1� ti CO3 FT1GE UPLIFT CONNECTION CROSS-REFERENCE MARK SIMPSON STRONG TIE USP MANUFACTURING, INC. O CONNECTOR CAPACITY FASTENERS CONNECTOR CAPACITY FASTENERS SYP SPF SYP SPF A HETA20 1810 9 -10d x 1 1/2" HTA20 1615 1585 10 -10d x 1 1/2" B HETA16 1810 9 -10d x 1 1/2" HTA16 1615 1585 10 - 10d x 1 112" C H2.5A 600 535 10 - 8d RT7A 670 565 10 - 8d X 1 1/2" D H3 455 320 8 - 8d RT3 610 525 18 - 8d X 1 1 /2" E META20 1450 7 -10d x 1 1/2" HTA20-18 1400 1400 10 -10d X 1 1/2" F HHETA20 2235 10 -10d x 1 1/2" G H10A 1340 1015 18 -10d x 1 1/2" RT16A 1380 1160 9-10d X 1 1/2"& 8-10d H HTT4 3610 3105 5W ANCH.118 10dx1.1/2 HTT4 2715 5/8" ANCH.120 10dx1-112 J HTT5 4350 3740 518" ANCH.1 26 10dxl-1/2" HTT5 3225 5/8" ANCH. l(28)10dx1-1/2 K H 5/8"DIA. BOLTS TDX2-TZ 2345 — 2 - 5/8" DIA. BOLTS L 5/8" ANCH. 3/4" STUD BOLTS TDX6 5320 — 2 - 7/8' DIA. BOLTS M HD7B * 6645 5650 718" ANCH. 3/4" STUD BOLTS TDX10 7845 — 4 - 7/8" DIA. BOLTS N 1165l107 *" 1005/915 *' 8 -10d x 3" JUS26 1115/1060** — 8 -10d P HUS26 1550/3335 " 1335/2820 ** 20 -16d x 3 1/2" HUS26 1925/3295 — (20)16d x 3-1/2" Q HUS28 2000/4220 ** 1720/3125 " 30 -16d x 31/2" HUS28 2570/4345 — 30d -16d x 3-1/2" R MTS12 1000 860 14 -10d x 1 1/2" MTW12 1195 1005 14-10d x 1-1/2" S MTS16 1000 860 14 -10d x 1 1/2" MTW16 1195 1005 14-10d x 1-1/2" T MTS20 1000 860 14 -10d x 1 1/2" MTW20 1195 1 1005 14-10d x 1-1/2" U MGT/MUGT 3140 3140 22 -10d X 1 5/8" ATR W/ 5" EMBED W/ SIMPSON "SET" EPDXY V LGT2 2150 1850 (16)16d SINKERS & (7)1/4" x 2-1/4" TITENS LUGT2 1850 1810 (16)10d NAILS AND (5) 1/4" x 3" WEDGE BOLTS "X" HTS 20 1450 1245 24-1Od X 1 1/2" HTW20 1530 1285 24-1 Old X 1 1/2" SP1 585 535 10 -10d SPT22 685 8 - 10d SP2 1065 605 12 -10d SPT24 1030 12 -10d 645 555 12-10d X 1 1/2" * MINIMUM 3" MEMBER ** REACTIONS ARE FOR ROOF LOADS ONLY *** DO NOT DRIVE NAILS THROUGH THE TRUSS PLATE ON THE OPPOSITE SIDE OF THE TRUSS, WHICH COULD FORCE THE PLATE OFF OF THE TRUSS. ALL EPDXY ANCHORS USP CIA-7000C NOTE: DOUBLE FELT REQ'D ON ROOF PITCHES 3/12 & LOWER. LOADS - ROOF = L / 360 FLOOR = L / 480 W/ 3/8" MAX DEFLECTION. FLOOR JOIST SPACING SHALL BE MAX OF 19.2" OC FOR HARDWOOD & TILE AREA'S & 24" OC FOR CARPET AREA'S DROP HIP DETAIL 240-0 MAXIUM SPACING ON VERTICALS OF (B) TRUSS (++) (B) ce) (A) (+ 1 OR 2 PlY CARRIER 1-8-8 CLEAR GAP BETWEEN (B) TRUSSES (+/- 6") *FASTEN EACH (B) TRUSS WEB TO EACH (A) TRUSS TOP CHORD @ EVERY INTERSECTING POINT SHOWN ON THE HIP TRUSS SYSTEM BELOW. FASTEN TOP CHORDS OF EACH (B) TRUSS TO THE TOP CHORDS OF (A) TRUSSES AT EVERY OTHER INTERSECTING POINT ("). (B INTERSECTING POINT TO BE FASTENED WITH 2 -16d COMMON NAILS OR 0.128" x 3" GUN NAILS. FASTEN BOTTOM CHORD OF (8) TRUSS TO TOP CHORD OF CARRIER TRUSS WITH (+) THE SAME SPECIFIED COMMON NAILS OR GUN NAILS AT 48" OC. (+) IN LIEU OF PREFABRICATED HIP PLANING TRUSSES, (B) 2x4 SO. PINE #2 OR #2 PT. STICK LUMBER (LAID FLAT WISE) MAY BE USED. FOLLOW FASTENING SCHEDULE AS DEFINED FOR HIP PLANING TRUSSES. R1 STICK FRAMING SPLICING IS ALLOWED BETWEEN TRUSSES OR AT TRUSS 1 OR �Y gRR�E CONT (A) T$ INTERSECTIONS. SPLICING LEDGER TO BE STAGGERED BETWEEN COMMON TRUSSES, NO CATS REQUIRED UNDER STICK FRAMING SPLICING. MINIMUM LENGTH OF STICK FRAMING TO BE 5-0" ON A HORIZONTAL PROJECTION. NOTE: SEE SHEET D-1 FOR ROOF FRAMING DETAILS 1. (2) 12d TOENAILS EACH SIDE OF FLOOR TRUSS TO WALL OR BEAM BELOW TYP @ INT. BEARING U.N.O. STRUCTURAL 2x STUDS SEE PLAN SHEATHING (SEE TB13 FOR INFO FOR NAILING INFO.) j PLYWOOD 2x6 CONT. W/ (2)-12d NAILS @ EA. TRUSS 2x CONT. W/ (2)-12d CANTILEVER NAILS @ EA. TRUS FLOOR TRUSS 2x4 CONT. RIBBON W/ (4) 16d NAILS @ EA. TRUSS 2x BLOCKING W/(2) -12d NAILS @ EA. END SEE PLAN TRUSS BRG. a ONNECTOR AT EACH TRUSS, 8d NAILS @ 24" O.C. SEE PLAN TO BLOCKING LINTEL SEE PLAN STRUCTURAL SHEATHING CO3),CANT. FLOOR TRUSS CONN. SCALE: 314" = 1'-0- MAIN FRAMING PLAN SCALE: Y4 t=1'-0° I Z o Z Z Q a Z V) 0 cn w 0 LLJ = s �o �Vi w ~1 M C t60.0 O1N U QCn U.) oq B D. N C B D C o o to ( rl L ,1 ILca To the best of the Engineer's knovded"ge, in oYmatl� d belief, the structural plans iuid'ssppeefifcation;,ccoo��>�fit'ed within these drawings comply wftA tiiti3037 ildrlda Building Code - Residential 6th Edition. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. C) z� 0 I>ic)O M Q 0 In •0 N Q Q)LL� Q `n rn cl� U d OC) Q � � WJ z M C:) d' oz zd 48Ir �z8o z Q zWz14 _l �W EgEJ .8 00 z l-L® 0 ZLO o r N ¢ DC � Z I U L o ..o O OW Z = Ifu u- 'O tu- o 0 JOv YV�Y �QQ g82 <0 N c Wo aaaujo Z $�u-2 Z LLJ J Ln r-1 w U4 a � g o, 8 I- LV Q z Z U LLI a N N Z Z t I m IS0 4 Q w = 0 w SCALE : AS NOTED DATE : 3/18/2018 TECH: FFLORES VERSION NO. 10 SHEET NO. 7.0 '9 CJ1A CJ3A CJ5A CJ5A CJ3A CJ1A �1P 1-0 2 tMc� a 2 LO G X ¢ co /7� V-21 jr � 1 Mtan U U U 2 X CJ1A CJ3A CJ5A EJ2 UPLIFT CONNECTION CROSS-REFERENCE MARK SIMPSON STRONG TIE USP MANUFACTURING, INC. O CONNECTOR CAPACITY FASTENERS CONNECTOR CAPACITY FASTENERS SYP SPF SYP SPF A HETA20 1810 9 - 10d x 1 1/2" HTA20 1615 1585 10 - 10d x 1 1/2" B HETA16 1810 9 -10d x 1 1/2" HTA16 1615 1585 10 -10d x 1 1/2" C H2.5A 600 535 10 - 8d RT7A 670 565 10 - 8d X 1 1/2" D H3 455 320 8 - 8d RT3 610 525 8 - 8d X 1 1/2" E META20 1450 7 - 10d x 1 1/2" HTA20-18 1400 1400 110 - 10d X 1 1/2" F HHETA20 2235 10 -10d x 1 1/2" G H10A 1340 1015 18 -10d x 1 1/2" RT16A 1380 1160 9-10d X 1 1/2"& 8-1Od H HTT4 3610 3105 5/8" ANCH. / 18 10dxl-112 HTT4 2715 5/8" ANCH.120 1061-1/2 J HTT5 3740 5/8" ANCH. 126 10dx1-1/2" HTT5 3225 5/8"ANCH.1(28)10dx1-1/2 K 5/8"DIA. BOLTS TDX2-TZ 2345 — 2 - 5/8" DIA. BOLTS L 143�5 5/8"ANCH. 3/4" STUD BOLTS TDX6 5320 — 2 - 7/8" DIA. BOLTS M HD7B * 7/8" ANCH. 314" STUD BOLTS TDX10 7845 — 4 - 7/8" DIA. BOLTS N I t jq96 1165/1070 ** 1005/ 15 ** 8 -10d x 3" JUS26 1115/1060** — 8 -10d P Ht JS26 1550/3335 ** 1335/2820 ** 20 -16d x 3 1/2" HUS26 1925/3295 — (20)16d x 3-1/2" Q HUS28 2000/4220 ** 1720/3125 ** 30 -16d x 3 1/2" HUS28 2570/4345 — 30d -16d x 3-1/2" R MTS12 1000 860 14 -10d x 1 1/2" MTW12 1195 1005 14-1Od x 1-1/2" S MTS 16 1000 860 14 -10d x 1 1/2" MTW 16 1195 1005 14-1 Od x 1-1 /2" T MTS20 1000 860 14 - 10d x 1 1/2" MTW20 1195 1005 14-10d x 1-1/2" MGT/MUGT 3140 3140 22 -10d X 1 5/8" ATR W/ 5" EMBED W/ SIMPSON "SET" EPDXY V LGT2 2150 1850 (16)16d SINKERS & (7) 1/4" x 2-1/4" TITENS LUGT2 1850 1810 (16)10d NAILS AND (5) 1/4" x 3" WEDGE BOLTS HTS 20 1450 1245 24-10d X 1 1/2" HTW20 1530 1285 24-10d X 1 1/2" SP1 585 535 10 -10d SPT22 685 8 -10d SP2 1065 605 12-10d SPT24 1030 12-10d 645 555 12-10d X 1 1/2" * MINIMUM 3" MEMBER ** REACTIONS ARE FOR ROOF LOADS ONLY *** DO NOT DRIVE NAILS THROUGH THE TRUSS PLATE ON THE OPPOSITE SIDE OF THE TRUSS, WHICH COULD FORCE THE PLATE OFF OF THE TRUSS. ALL EPDXY ANCHORS USP CIA-7000C NOTE: DOUBLE FELT REQ'D ON ROOF PITCHES 3/12 & LOWER. LOADS - ROOF = L / 360 FLOOR = L / 480 W/ 3/8" MAX DEFLECTION. FLOOR JOIST SPACING SHALL BE MAX OF 19.2" OC FOR HARDWOOD & TILE AREA'S & 24" OC FOR CARPET AREA'S DROP HIP DETAIL 2-M MAXIUM SPACING ON VERTICALS OF (B) TRUSS (++) (B) (B) (A) (+ 1 OR 2 PLY CARRIER 1-8-8 CLEAR GAP BETWEEN (B) TRUSSES (+/- 6*) *FASTEN EACH (B) TRUSS WEB TO EACH (A) TRUSS TOP CHORD @ EVERY INTERSECTING POINT SHOWN ON THE HIP TRUSS SYSTEM BELOW. FASTEN TOP CHORDS OF EACH (B) TRUSS TO THE TOP CHORDS OF (A) TRUSSES AT EVERY OTHER INTERSECTING POINT ("). (B INTERSECTING POINT TO BE FASTENED WITH 2 -16d COMMON NAILS OR 0.128" x 3" GUN NAILS. FASTEN BOTTOM CHORD OF (B) TRUSS TO TOP CHORD OF CARRIER TRUSS WITH (+) THE SAME SPECIFIED COMMON NAILS OR GUN NAILS AT 48" OC. (+) IN LIEU OF PREFABRICATED HIP PLANING TRUSSES, (8) 20 SO. PINE #2 OR #2 PT. STICK LUMBER (LAID FLAT WISE) MAY BE USED. FOLLOW FASTENING SCHEDULE AS DEFINED FOR HIP PLANING TRUSSES. R1 STICK FRAMING SPLICING IS ALLOWED BETWEEN TRUSSES OR AT TRUSS ROE 1 OR PLY LEDGER (A) INTERSECTIONS. SPLICING TO BE STAGGERED BETWEEN COMMON TRUSSES, NO CATS REQUIRED UNDER STICK FRAMING SPLICING. MINIMUM LENGTH OF STICK FRAMING TO BE 5'-0" ON A HORIZONTAL PROJECTION. NOTE: SEE SHEET D-1 FOR ROOF FRAMING DETAILS 1. (2) 12d TOENAILS EACH SIDE OF FLOOR TRUSS TO WALL OR BEAM BELOW TYP @ INT. BEARING U.N.O. ROOF FRAMING PLAN 0 z,�,o Z Z �t a- z V� U' cn +-j w (10 I) O c = E Cn ~ r- CIO w m c m cn U . LO B D. _ ••� N Ns W uz W , N To the best of the Engin f y kn , and belief, the structural plans , 1caft ontaigi�'t within these drawings compltl IY41'�tlsf�Q}7,FjIpE►11. Building Code - Residential 6th EditidA t Ei�1s signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. 0 Z 0 0 z I>•+�MO M Q�MLn a cn•�d' o Q LL z M 0Y U M a Ev z Z CD J W CD Z W za a z CL �48t, SLCL R+ �Z O� o $ J g��s W L 00 L 18 Z 1 LL �3 Ln o U �_ O uj uj fo a u-LLJ O nJ � �0gg t\ FF-- Z J rl •" LLJ o�Fl- O tYj 2 F U-6 W Z Lu Fg m 06 Z � _ rn O ,-a a rn SCALE : AS NOTED DATE : 3/18/2018 TECH: FFLORES VERSION NO" 10 SHEET NO. 7.1 GENERAL INSTALLATION NOTES 1, Provide full mortar head and bed joints. 2. Shore filled lintels as required. 3. Installation of lintel must comply with the architectural and/or structural drawings. 4. U-Lintels are manufactured with 5-112" long notches at the ends to accommodate vertical cell reinforcing and grouting. 5. All lintels meet or exceed U360 vertical deflection, except lintels 17'-4" and longer with a nominal height of 8" meet or exceed L/180. 6. Bottom field added rebar to be located at the bottom of the lintel cavity. 7, 7/32" diameter wire stirrups are welded to the bottom steel for mechanical anchorage. 8. Cast -in -place concrete may be provided in composite lintel in lieu of concrete masonry units. 9. Safe load ratings based on rational design analysis per ACI 318 and ACI 530 10. Product Approvals: Miami Dade County, Florida Nos.03-0605.05 and 03-0605.04. 11. The exterior surface of lintels installed in exterior concrete masonry walls shall have a coating of stucco applied in accordance with ASTM C-926 or other approved coating. 12. Lintels loaded simultaneously with veritcal (gravity and uplift) and horizontal (lateral) loads shoud be checked for combine loading with the following equation: Applied vertical load 4 Applied horizontal load . 0 a e vertical load Safe horizontal load GENERAL CONCRETE LINTEL SCHEDULE APPROVED LINTEL MANUFACTURERS: CASTE-CRETE, QUALITY 8 8RF14-0B/1T 8F16-O T 8F16-1B/1T UV 8F441B/1T8F401B/1T 8RF400B/1T 8F321B/1T FORM do GROUT SOLID O e1- W � J 0 #5 BAR CONT. 8F12-1 B/1 T "V" LINTEL DETAIL SCALE = N.T.S. E �I € � F = FILLED WITH GROUT / U = UNFILLED R = RECESSED QTY. OF #5 REBAR @ BOTTOM OF LINTEL CAVITY i J tJ w 8 F 16— B/ 1 T Z tNOMINAL. QUANTITY OF WIDTH #5 REBAR AT TOP NOMINAL - HEIGHT MATERIALS c'i"f' precast ifntels = 3500 psi. 2. fc prestressed lintels = 6000 psi. 3, grouted per ASTM C476 fg = 3000 psi w/ 4. maximum 318" aggregate and 8" to 11" slump. 5. Concrete masonry units (CMU) per ASTM C90 w/ minimum net area compressive strength = 1900 psi. 6. Reber per ASTM A615 Grade 60. Prestressing strand per ASTM A416 grade 7. 270 low relaxation. 7/32 wire per ASTM A510. 8. Mortar per ASTM C270 type M or S. #S EBAR .(1)RE MIN. TTOP (1) REQ'D CLEAR ALTERNATE POWERS STEEL LINTEL O A e ° < M.U. #5 REBAR AT TOP a° n e GROUT MIN. ° 4 ° _ D D 1-1/2"CLEAR a a ° < J a m a 5 REBAR AT F = — W BOTTOM OF tr� LU 4 — o LINTEL CAVITY igr w po X W \ Lu ` Z nA —BOTTOM Ct Lu U O REINFORCING PROVIDED IN LINTEL o Ch _JJ` Z — O w ,r, ¢ 5 3 m D D � #5 REBAR AT BOTTC 7-518"ACTUAL " NOMINAL WIDTH (VARIES) r~n � R I✓ <�Io AS INDICATED LINTEL MINIMUM DEPTHS ARE CALLED OUT ON LINTEL PLAN. IF CONTRACTOR INSTALLS A DEEPER LINTEL THAN INDICATED ON THE PLAN, DOING THIS INCREASES THE STRENGTH OF THE LINTEL AND IS APPROVED WITHOUT ENGINEERING LETTER. IF A SMALLER LINTEL IS INSTALLED CONTACT E.O.R. FOR APPROVAL. (SEE LINTEL PLAN FOR SCHEDULE) 16 GAUGE POWERS STEEL BOXED LINTEL POWERS STEEL BOXED LINTEL NOTES (ALT.) ONLY IF NOTED ON LINTEL PLAN 1. Refer to manufacturer's specifications for Installation. 2. Contractor to provide proper protection of lintel to prevent rusting Refer to manufacturer's specifications. 3. If lintel is scratched or damaged refer to Powers Steel for repair. 4. Lintel depth to match precast depth. One #5 Bar required at top see lintel plan/details for bottom steel required. 5. A bonding agent must be applied to the Steel Box lintels prior to applying the cementitivas coating. See convector specifications O 4'-6" LL L MIN. O 7'-4" LL .L LINTEL PLAN SCALE: Y4'=1'-0" U' Z t$ zslam Q a Cn (D Q) cn w O"' rz E U) C111 �tli o 0 co r` C) U — U �04 co 2 m O N _ = LL OD p C) Q tM B D.,.¢,' N c S D C C,U)00 m� u' -�. O .•. Z. IL To the best of the Engineer's knd l��11�tt jn£gr' R, and belief, the structural plans and sped tati611A lntaina within these drawings comply with the 2017 Florida Building Code -Residential 6th Edition. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. 0 z0 0 L>i�Mp fM Q a in •� � < L- M I-- j:e U .--t 00 Q E Z WJ C) MJ OZ Z a f F- �Z80 U Z Q Z 8 M 0 ) o Ie O 0 L 0/ Z p v � N H ^ L N �• �zr r w, W L O ^ ZZC `Q 0 �� a w �Y� J X86 K M a �oa Z ^ rl u_ ace LU 2 Lli Q W 2: Z < ce 2 V W~ N k N Z� Z LJJ z J R aLu o 00 g f SCALE : AS NOTED DATE : 3/18/2018 TECH: FFLORES VERSION No' 10 SHEET NO. 8.0 NOTE: BORATE/ SENTRA CON SYSTEM APPLIED TO ALL FRAME MEMBERS WITHIN 24" A.F.F. 1) METHOD OF TREATMENT SHALL BE APPROVED BY THE GOVERNING JURISDICTION "LIQUID BORATE OR BOR-A-COR" PRODUCT METHODS MUST BE DETERMINED AT PERMIT STAGE. 2) PRESSURE TREATED LUMBER THAT HAS BEEN CUT OR DRILLED THAT EXPOSES UNTREATED PORTIONS OF WOOD ARE REQUIRED TO BE FIELD TREATED TO PREVENT INSECT INFESTATION. ATTENTION: CHEMICAL CHANGES IN PRESSURE TREATED WOODS F BER 1 2 0 HROMATED COPPER ARSENATE CCA-C WILL NO LONGER BE PRODUCED FOR RESIDENTIAL OR GENERAL AS 0 DECEM 3 ST, 0 3, C ( ) U E PRESSURE TREATED WOOD ALTERNATIVES HAVE BEEN CREATED T CONSUMER USE SEVERAL N VE L W E S O REPLACE CCA-C. MANY OF THE NEW PRESSURE TREATED WOODS USE CHEMICALS THAT ARE CORROSIVE TO STEEL. IT IS THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THE TYPE OF WOOD TREATMENT AND TO SELECT APPROPRIATE CONNECTORS THAT RESIST CORROSION. FOR EXAMPLE, ACQ-C, ACQ-D, CBA-A, OR CA-B REQUIRE HOT -DIPPED GALVANIZED OR STAINLESS STEEL FASTENERS. DOT SODIUM BORATE (SBX) DOES NOT. REQUIRED SAFETY GLAZING IN HAZARDOUS LOCATIONS (RE: FBRC R308.4) R308.3 HUMAN IMPACT LOADS. INDIVIDUAL GLAZED AREAS INCLUDING GLASS MIRRORS IN HAZARDOUS LOCATIONS SUCH AS THOSE INDICATED AS DEFINED IN SECTION R308.4 SHALL PASS THE TEST REQUIREMENTS OF CPSC 16 CFR, PART 1201 CRITERIA FOR CATEGORY I OR CATEGORY II AS INDICATED IN TABLE R308.3.1 EXCEPTIONS: 1, POLISHED WIRED GLASS FOR USE IN FIRE DOORS AND OTHER FIRE RESISTANT LOCATIONS SHALL COMPANY WITH ANSI Z97.1-14 2. LOUVERED WINDOWS AND JALOUSIES SHALL COMPANY WITH SECTION R308.2 R308.4 HAZARDOUS LOCATIONS. THE FOLLOWING SHALL BE CONSIDERED SPECIFIC HAZARDOUS LOCATIONS FOR THE PURPOSE OF GLAZING: 1. GLAZING IN SWINGING DOORS EXCEPT JALOUSIES. 2. GLAZING IN FIXED AND SLIDING PANELS OF SLIDING DOOR ASSEMBLIES AND PANELS IN SLIDING AND BIFOLD CLOSET DOOR ASSEMBLIES. 3. GLAZING IN STORM DOORS. 4. GLAZING IN ALL UNFRAMED SWINGING DOORS. 5. GLAZING IN DOORS AND ENCLOSURES FOR HOT TUBS, WHIRLPOOLS, SAUNAS, STEAM ROOMS, BATHTUBS, AND SHOWERS. GLAZING IN ANY PART OF A BUILDING WALL ENCLOSING THESE COMPARTMENTS WHERE THE BOTTOM EXPOSED EDGE OF THE GLAZING IS LESS THAN 60 INCHES (1524MM) MEASURED VERTICALLY ABOVE ANY STANDING OR WALKING SURFACE. 6. GLAZING, IN AN INDIVIDUAL FIXED OR OPERABLE PANEL ADJACENT TO A DOOR WHERE THE NEAREST VERTICAL EDGE IS WITHIN A 24-INCH(610MM) ARC OF THE DOOR IN A CLOSED POSITION AND WHOSE BOTTOM EDGE IS LESS THAN 60 INCHES (1524MM) ABOVE THE FLOOR OR WALKING SURFACE. 7. GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL, OTHER THAN THOSE LOCATIONS DESCRIBED IN ITEMS 5 AND 6 ABOVE, THAT MEETS ALL OF THE FOLLOWING CONDITIONS: 7.1 EXPOSED AREA OF AN INDIVIDUAL PANE GREATER THAN 9 SQUARE FEET (0.836 111,12). 7.2 BOTTOM EDGE LESS THAN 18 INCHES (457 MM) ABOVE THE FLOOR. 7.3 TOP EDGE GREATER THAN 36 INCHES (914 MM) ABOVE THE FLOOR. 7.4 ONE OR MORE WALKING SURFACES WITHIN 36 INCHES (914 MM) HORIZONTALLY OF THE GLAZING, 8. ALL GLAZING IN RAILINGS REGARDLESS OF AN AREA OR HEIGHT ABOVE WALKING SURFACE. INCLUDED ARE STRUCTURAL BALUSTER PANELS AND NONSTRUCTURAL IN FILL -PANELS, 9. GLAZING IN WALLS AND FENCES ENCLOSING INDOOR AND OUTDOOR SWIMMING POOLS, HOT TUBS AND SPAS WHERE THE BOTTOM EDGE OF THE GLAZING IS LESS THAN 60 INCHES (1524 MM) ABOVE A WALKING SURFACE AND WITHIN 60 INCHES (1524 MM) HORIZONTALLY OF THE WATER'S EDGE. THIS SHALL APPLY TO SINGLE GLAZING AND ALL PANES IN MULTIPLE GLAZING. 10. GLAZING ADJACENT TO STAIRWAYS, LANDINGS, AND RAMPS WITHIN 36 INCHES (914 MM) HORIZONTALLY OF A WALKING SURFACE WHEN THE EXPOSED SURFACE OF THE GLASS IS LESS THAN 60 INCHES (1524 MM) ABOVE THE PLANE OF THE ADJACENT WALKING SURFACE. 11. GLAZING ADJACENT TO STAIRWAYS WITHIN 60 INCHES (1524 MM) HORIZONTALLY OF THE BOTTOM TREAD OF A STAIRWAY IN ANY DIRECTION WHEN THE EXPOSED SURFACE OF THE GLASS IS LESS THAN 60 INCHES (1524 MM) ABOVE THE NOSE OF THE TREAD. EXCEPTION: THE FOLLOWING PRODUCTS, MATERIALS AND USES ARE EXEMPT FROM THE ABOVE HAZARDOUS LOCATIONS: 1. OPENINGS IN DOORS THROUGH WHICH A 3-INCH(76 MM) SPHERE IS UNABLE TO PASS. 2. DECORATIVE GLASS IN ITEMS 1, 6 OR 7. 3. GLAZING IN SECTION R308.4, ITEM 6, WHEN THERE IS AN INTERVENING WALL OR OTHER PERMANENT BARRIER BETWEEN THE DOOR AND THE GLAZING. 4. GLAZING IN SECTION R 308.4.2, ITEM 3, IN WALLS PERPENDICULAR TO THE PLANE OF THE DOOR IN A CLOSED POSITION OR WHERE ACCESS THROUGH THE DOOR IS TO A CLOSET OR STORAGE AREA 3 FEET (914 MM) OR LESS IN DEPTH. GLAZING IN THESE APPLICATIONS SHALL COMPANY WITH SECTION R308.4, ITEM 2. 5. GLAZING IN SECTION R308.4.3, WHEN A PROTECTIVE BAR IS INSTALLED ON THESE ACCESSIBLE SIDE(S) OF THE GLAZING 36 INCHES ± 2 INCHES (914 ± MM 51 MM) ABOVE THE FLOOR. THE BAR SHALL BE CAPABLE OF WITHSTANDING A HORIZONTAL LOAD OF 50 POUNDS PER LINEAR FOOT KG/M) WITHOUT CONTACTING THE GLASS AND BE A MINIMUM OF 1 ki INCHES (38 MM) IN HEIGHT. 6. OUTBOARD PANES IN INSULATING GLASS UNITS AND OTHER MULTIPLE GLAZED PANELS IN SECTION R308.4, ITEM 7, WHEN THE BOTTOM EDGE OF THE GLASS IS 25 FEET (7620 MM) OR MORE ABOVE GRADE, A ROOF, WALKING SURFACES, OR OTHER HORIZONTAL (WITHIN 45 DEGREES (0.79 RAD) OF HORIZONTAL] SURFACE ADJACENT TO THE GLASS EXTERIOR. 7. LOUVERED WINDOWS AND JALOUSIES COMPLYING WITH THE REQUIREMENTS OF SECTION R308.2. 8. MIRRORS AND OTHER GLASS PANELS MOUNTED OR HUNG ON A SURFACE THAT PROVIDES A CONTINUOUS BACKING SUPPORT. 9. SAFETY GLAZING IN SECTION R308.4, IS NOT REQUIRED WHERE: 9.1 THE SIDE OF STAIRWAY, LANDING OR RAMP HAS A GUARDRAIL OR HANDRAIL, INCLUDING BALUSTERS OR IN -FILL PANELS, COMPLYING WITH THE PREVISIONS OF SECTION 1014 OF THE FLORIDA BUILDING CODE, BUILDING; AND 9.2 THE PLANE OF THE GLASS IS GREATER THEN 18 INCHES (457 MM) FROM THE RAILING. 1. SPECIFICATIONS 1.1. CONSTRUCTION: 1. 1. 1. ACI 318-14 BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE 1.1.2. ACI 530-13, ASCE 5/TMS 402-16 & ACI 530.1-13, ASCE 6/TMS 602-16 SPECIFICATIONS FOR MASONRY STRUCTURES. 1.1.3. ASTM C270-12a, C90-06b & C91-05 SPECIFICATIONS FOR MASONRY STRUCTURES 1.1.4. NATIONAL DESIGN SPECIFICATIONS (NDS) FOR WOOD CONSTRUCTION, 2015 EDITION, AND ALL ACCOMPANYING SUPPLEMENTS. 1.1.5. FLORIDA RESIDENTIAL CODE (FBC-R), FLORIDA BUILDING CODE (FBC) 6th ed. (2017) 1.1.6. "MANUAL OF STEEL CONSTRUCTION, ALLOWABLE STRESS DESIGN", BY THE AMERICAN INSTITUTE OF STEEL CONSTRUCTION, (AISC) 13TH EDITION. 1.1.7. "DESIGN SPECIFICATION FOR LIGHT METAL PLATE CONNECTED WOOD TRUSSES" BY THE TRUSS PLATE INSTITUTE TRI1-14. 1.2. DESIGN: 1.2.1. ACI 301-11 BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE 1.2.2. ACI 530-13, ASCE 5/TMS 402-16 & ACI 530.1-13, ASCE 6/TMS 602-16 SPECIFICATIONS FOR MASONRY STRUCTURES. 1.2.3. ASTM C270-12a, C90-06b & C91-05 SPECIFICATIONS FOR MASONRY STRUCTURES 1.2.4. NATIONAL DESIGN SPECIFICATIONS (NDS) FOR WOOD CONSTRUCTION, 2015 EDITION, AND ALL ACCOMPANYING SUPPLEMENTS. 1.2.5. PLYWOOD DESIGN SPECIFICATIONS (APA) 1.2.6. FLORIDA BUILDING CODE (FBC) 6th ed. (2017) AND FLORIDA BUILDING CODE 6th ed. RESIDENTIAL (FBCR) 1.3. SHOP DRAWINGS 1.3.1. THERE SHALL NOT BE ANY DEVIATIONS FROM THESE DESIGN PLANS BY OTHERS DURING THE PREPARATION OF SHOP DRAWINGS WITHOUT WRITTEN APPROVAL FROM THE ENGINEER OF RECORD. 1.3.2. ALL SHOP DRAWINGS ARE TO BE SUBMITTED TO THE ENGINEER OF RECORD PRIOR TO THE COMMENCEMENT OF CONSTRUCTION. 1.3.3. ALL ROOF AND FLOOR TRUSS SHOP DRAWINGS ARE TO BE SIGNED AND SEALED BY A FLA. REG. PE. AND SHALL INCLUDE: DRAWINGS AND CALCULATIONS, REACTIONS AND BEARING POINTS, BRACING REQUIREMENTS, AND CONNECTIONS TO SUPPORTING TRUSS MEMBERS. 2. DESIGN LOADS 2.1. DEAD LOADS : 2.1.1. UNIT WEIGHT OF SOIL, COMPACTED: 120 PCF 2.1.2. UNIT WEIGHT OF REINFORCED CONCRETE: 150 PCF 2.1.3. UNIT WEIGHT OF 8" C.M.U. BLOCK: 55 PSF 2.1.4. 1ST FLOOR SUPERIMPOSED LOAD: 20 PSF 2.1.5. UNIT WEIGHT OF 2x4 PARTITION WALLS: 11 PSF 2.1.6. UNIT WEIGHT OF 2x6 BEARING WALLS: 12 PSF 2.1.7. BALCONIES & DECKS: 15 PSF 2. 1.8. TILE ROOF TOP CHORD : 15 PSF BOTTOM CHORD: 10 PSF 2.1.9. SHINGLE ROOF TOP CHORD : 7 PSF BOTTOM CHORD: 10 PSF 2.1.10. FLOOR TRUSSES 15 2.2. LIVE LOADS: 2.2.1. SIDEWALK AND DRIVEWAY LOAD: 250 PSF 2.2.2. GARAGE LOADS : 40 PSF 2.2.3. PARTITIONED ROOMS: 40 PSF 2.2.4. BALCONY AND DECKS: 60 PSF-UNDER 100 sq. ft. 2.2.5. STAIRWAYS AND LANDINGS: 40 PSF 2.2.6. SLEEPING ROOMS: 30 PSF 2.2.7. FLOOR TRUSS TOP CHORD MINIMUM: 40 PSF 2.2.8. ROOFTRUSS TOP CHORD MINIMUM: 20 PSF BOTTOM CHORD (ATTIC W/O LIMITED STORAGE) : 10 PSF (NON -CONCURRENT) BOTTOM CHORD (ATTIC W/ LIMITED STORAGE) : 20 PSF 2.3. RAILING LOADS: 2.3. 1. ALL RAILING AND GUARD RAIL SYSTEM'S ARE TO BE DESIGNED TO WITHSTAND A CONCENTRATED LOAD OF 200 POUNDS APPLIED AT ANY POINT AND IN ANY DIRECTION ON THE RAILING. 2.3.2. ALL RAILING AND GUARD RAIL SYSTEM'S ARE TO BE DESIGNED TO WITHSTAND A HORIZONTAL LOAD OF 50 PLF ON THE GUARDRAIL AND A SIMULTANEOUS LOAD OF 100 PLF APPLIED VERTICALLY DOWNWARD AT THE TOP OF THE GUARDRAIL 2.3.3. GUARDRAIL SYSTEM SHALL BE DESIGNED TO WITHSTAND 2001b CONCENTRATED HORIZONTAL LOAD APPLIED ON 1 SQ. FT. AT ANY POINT IN THE SYSTEM. 2.3.4. 2.3.1., 2.3.2 & 2.3.3. ARE NOT REQUIRED TO BE APPLIED SIMULTANEOUSLY, BUT EACH SHALL BE APPLIED TO PRODUCE THE MAXIMUM STRESSES IN THE MEMBER COMPONENTS. 2.4. WIND LOADS: 2.4.1. WIND DESIGN TO BE CONDUCTED IN ACCORDANCE WITH SECT. R301.2 OF THE FBC 6th ed. (2017), AND CONDUCTED BASED ON A140 MPH 3 SECOND GUST, EXPOSURE "C", IMPORTANCE FACTOR "I" =1.0. ENCLOSED BUILDING 2.4.2. NET UPLIFT DEAD LOADS -10 PSF SHINGLE, 15 PSF TILE 2.4.3. WIND LOAD DETERMINATION BASED ON ASCE 7-10 2.5. DEFLECTIONS: 2.6.1. FLOOR TRUSSES SHALL LIMIT DEFLECTION TO U480TIMES THE SPAN FOR LIVE LOADS AND U240 TIMES THE SPAN FOR TOTAL LOAD. 3. DESIGN METHOD 3.1. LOAD FACTOR DESIGN: 3. 1. 1. THE LOAD FACTOR DESIGN METHOD WAS USED TO DESIGN: CAST -IN -PLACE CONCRETE SLABS AND FOOTINGS 3.2. SERVICE LOAD DESIGN: 3.2.1. THE SERVICE LOAD DESIGN METHOD WAS USED TO DESIGN: MASONRY WALLS AND LINTELS INTERIOR AND EXTERIOR WOOD FRAMING AND SHEATHING STAIRS AND FLOOR FRAMING ROOF FRAMING, SHEATHING AND UPLIFT 3.3. LOAD COMBINATIONS FOR LRFD DESIGNS: 3.3.1. THE FOLLOWING LOAD COMBINATIONS WERE DESIGNED FOR: TOTAL DL + FLOOR LL + ROOF ILL TOTAL DL + FLOOR ILL + WL TOTAL DL + WL 3.3.2. ALL ROOF AND FLOOR TRUSSES SHALL BE DESIGNED TO RESIST THE WORST LOAD COMBINATION RESULTING IN THE MAXIMUM STRESSES PLACED ON THAT COMPONENT. BOTH PARTIAL, FULL, AND ALTERNATING SPAN LOADING ARE TO BE CONSIDERED. 3.4. DESIGN ASSUMPTIONS: 3.4.1. ALL FOUNDATIONS ARE CENTERED UNDER SUPPORTED COLUMNS AND WALLS UNLESS SHOWN OTHERWISE IN THE DESIGN PLANS. 4• MATERIALS 4.1. REINFORCING STEEL: 4. 1. 1. REINFORCING STEEL SHALL BE ASTM A615 / A6151M-12 MIN. GRADE 40, fy = 40 Ksi 4.1.2. LAP SPLICE SHALL BE AS FOLLOWS: #5 BAR 25", #4 BAR 20", #3 BAR 20". 4.1.3. ALL DIMENSIONS PERTAINING TO THE LOCATION OF REINFORCING ARE TO THE CENTERLINE OF EACH BAR EXCEPT WHERE THE COVER DIMENSION IS SHOWN TO THE FACE OF THE CONCRETE. 4.1.4. REINFORCING DETAIL DIMENSIONS ARE OUT TO OUT OF BARS. 4.1.5. REINFORCING MECHANICAL COUPLERS ARE TO DEVELOP 125 % OF THE REQUIRED YIELD STRENGTH OF THE BAR AND ARE TO BE APPROVED BY THE ENGINEER OF RECORD. 4.1.6. DESIGN COVER REQUIREMENTS: C-I-P CONCRETE FORMED AGAINST EARTH: 3" C-I-P CONCRETE EXPOSED TO EXTERIOR: 2" C-I-P CONCRETE NOT EXPOSED: 1 1 y„ GROUT FILLED MASONRY: 4.1.7. WELDED WIRE FABRIC (WWF): ASTM A-185 / A 185M-14 4. 1.8. DETAIL REINFORCEMENT IN ACCORDANCE WITH ACI 318-11 (STRUCTURAL CONCRETE) ACI 530-13 (MASONRY STRUCTURES) 4.2. CONCRETE: 4.2.1. CONCRETE TYPE MIN. 28 DAY DESIGN (fc) MODULES OF ELASTICITY DESIGN (E) C-1-P CONCRETE (NORMAL WEIGHT) 2,500 Psi 2,850 Ksi C-I-P CONCRETE (NORMAL WEIGHT) HERNANDO CO. ONLY 3,000 Psi 3,122 Ksi C-I-P GROUT 3,000 Psi 3,122 Ksi 4.2.2. CONCRETE SHALL CONSIST OF 1" MAXIMUM AGGREGATE CONCRETE MIX WITH SLUMP BETWEEN 6" AND 7" AT TIME OF PLACEMENT. SEE SPECIFICATIONS FOR ADDITIONAL CRITERIA. 4.2.3. GROUT SHALL CONSIST OF PEA ROCK (3/8" MAXIMUM AGGREGATE) CONCRETE MIX WITH SLUMP BETWEEN 8" AND 10" AT TIME OF PLACEMENT. SEE SPECIFICATIONS FOR ADDITIONAL CRITERIA. 4.2.4. CONSTRUCTION JOINTS WILL BE PERMITTED 4.2.5. METHOD OF CONCRETE FORMING, PLACEMENT AND CURING SHALL BE CONDUCTED IN ACCORDANCE WITH THE SPECIFICATIONS AS STATED. 4.2.6. EARTH SUPPORTED SLABS (EXCLUDING EXTERIOR WALKWAYS & DRIVEWAYS) : 31/2" MIN. THICKNESS W/ MIN. REINFORCEMENT OF 6.0 x 6.0 W/ 1.4 x 1.4 WWF @ MID -DEPTH OF SLAB. FIBER MESH PER DESIGN MIX MAY BE USED I.L.O. WWF @ CONTRACTORS DISCRETION. 4.2.7. CONCRETE PLACEMENT PRACTICES SHALL BE IN ACCORDANCE W/ ALL ACI- MCP 2011 STANDARDS. 4.3. CONCRETE MASONRY: 4. 3. 1. FILLED CELLS W/ (1) #5 BAR SHALL BE LOCATED PER PLAN. 4.3.2. LOAD BEARING CONCRETE MASONRY BLOCK SHALL BE ASTM C90-0601, TYPE II NON -MOISTURE CONTROLLED. 4.3.3. ALL CELLS & CAVITIES BELOW GRADE WILL BE FILLED W/ CONCRETE IN ALL STEM WALLS. 4.3.4. THE AGGREGATE STRENGTH OF THE BLOCK AND MORTAR SHALL BE F'm =1,500 PSI MINIMUM. 4.3.5. METHOD OF CONCRETE MASONRY PLACEMENT AND CONSTRUCTION SHALL BE CONDUCTED IN ACCORDANCE WITH THE SPECIFICATIONS AS STATED. 4.3.6. MORTAR SHALL BE ASTM C270 TYPE "S" FOR ALL MASONRY CONSTRUCTION. 4.4. STRUCTURAL LUMBER: 4.4. 1.1. INTERIOR LOAD BEARING WALLS SPF #2 ALL EXTERIOR FRAMING SPF #2 4.4. 1.2. ALL FRAME WALLS TO BE CONSTRUCTED USING SPF #2, STUD QUALITY OR BETTER 4.4. 1.2.1 ALL HEADER, BEAMS, COLUMNS ETC. TO BE SYP #2 OR BETTER 4.4.2. ALL PLYWOOD USED FOR EXTERIOR APPLICATIONS SHALL BE APA RATED STRUCTURAL SHEATHING 15/32" EXP 1 OR 7/16" STRUCTURAL 1, U.N.O. 4.4.3. ALL PLYWOOD USED FOR INTERIOR APPLICATIONS SUCH AS SUB FLOORING AND SHEAR WALLS SHALL BE APA RATED SHEATHING EXP 1 U.N.O. 4.4.4. IF OSB BOARD IS TO BE USED IN PLACE OF PLYWOOD IS TO HAVE SIMILAR OR GREATER SECTION PROPERTIES. 4.4.5. ONLY STRUCTURAL LUMBER TO BE USED FOR AN EXTERIOR APPLICATION. WOOD IN CONTACT WITH CONCRETE IS TO RECEIVE A STANDARD GRADE PRESSURE TREATING. 4.4.6. WHEN PRE ENGINEERED TRUSSES ARE CALLED FOR ON THE PLANS THE MANUFACTURER IS TO SUBMIT SHOP DRAWINGS TO THE ENGINEER OF RECORD. 4.4.7. DESIGN, FABRICATE AND ERECT WOOD TRUSSES IN ACCORDANCE WITH THE "DESIGN SPECIFICATION FOR LIGHT METAL PLATE CONNECTED WOOD TRUSSES" BY THE ANSI/TPI 1-2007, BCSI 4.4.8. UNTREATED WOOD SHALL NOT BE IN DIRECT CONTACT WITH CONCRETE. SEAT PLATES SHALL BE PROVIDED AT BEARING LOCATIONS WITHOUT WOODEN TOP PLATES. 4.4.9. ALL EXTERIOR FRAME WALLS SHALL BE STUCCO FINISH- 7/8" STUCCO FINISH PER ASTM C. 926, APPLY 3 LAYERS W/ TOTAL THICKNESS 7/8" OVER METAL LATH. FIRST 2 LAYERS 3/8" THICK EACH. 3RD LAYER 1/8" THICK 4.4.10. INSTALLATION OF EXTERIOR LATHING & FRAMING SHALL COMPLY TO ASTM C 1063 PER FLORIDA CODE R703.7 4.5. FASTENERS AND TIE DOWNS: 4. 5. 1. FASTENERS AND TIE DOWNS SHALL CONSIST OF BUT ARE NOT LIMITED TO: SHAPES, ANGLES, CHANNELS: ASTM A36/36M 05 Fy = 36 Ksi ROUND METAL PIPE: ASTM A53, GRADE B Fy = 35 Ksi SQUARE METAL TUBING: ASTM A500, GRADE B Fy = 46Ksi HIGH STRENGTH BOLTS: ASTM A325 MACHINE BOLTS: GALVANIZED ASTM A307 4.5.2. SHEET METAL ACCESSORIES SHALL CONFORM TO: Fy = 33KsiWITH G90 GALVANIZED COATING IN ACCORDANCE WITH ASTM A525-87. 4. 5. 3. NAILS SHALL CONSIST OF: COMMON WIRE NAILS WITH MINIMUM DIAMETER AS FOLLOWS: 8d = 0.131",10d = 0.148", 12d = 0.148",16d = 0.162". 4.5.4. ALL FASTENERS AND TIE DOWNS EMBEDDED IN CONCRETE OR USED IN AN EXTERIOR APPLICATION ARE TO RECEIVE AN ANTI -CORROSIVE COATING BY MANUFACTURER PRIOR TO INSTALLATION. 4.5.5. ALL FASTENERS AND TIE DOWNS ARE TO PROVIDE THE UPLIFT CAPACITY CALLED FOR IN THE PLANS ARE A MINIMUM. 4.5.6. ALL FASTENER TIE DOWNS, BEAM HANGERS, JOIST HANGERS, AND FLOOR TRUSS STRAPPING ARE TO BE INSTALLED IN ACCORDANCE WITH THE PLANS AND SPECIFICATIONS. 4.5.7. CONCRETE EMBEDDED'J' BOLTS USED FOR UPLIFT ARE TO BE WET SET PRIOR TO INITIAL SET OF THE CONCRETE, SPACING AND ALIGNMENT ARE TO BE IN ACCORDANCE WITH THE DESIGN PLANS, U.N.O. ALTERNATES TO 7' BOLTS ARE NOTED ON PLANS. 4.5.8. CONCRETE EMBEDDED TIE DOWNS USED FOR TRUSS AND WALL UPLIFT ARE TO BE PLACED AROUND EMBEDDED REINFORCING PRIOR TO OR WHILE PLACING GROUT. 4.6. MICRO -LAM LUMBER: 4.6.1. MICRO -LAM STRESS GRADES SHALL PROVIDE THE FOLLOWING MINIMUM PROPERTIES: E = 2,000,000 PSI Fb = 2,950 PSI Ft = 1,850 PSI Fc = 500 PSI (PERPENDICULAR) Fc = 2,700 (PARALLEL) 4.7. STEEL: Fv= 285PSI 4.7.1. INSTALLATION OF ALL STEEL TO BE PERFORMED BY AN EXPERIENCED, QUALIFIED STEEL ERECTOR. 4.7.2. FABRICATE AND ERECT ALL STRUCTURAL STEEL IN ACCORDANCE WITH A.I.S.C. "SPECIFICATION FOR THE DESIGN, FABRICATION, AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS". 4.7.3. STRUCTURAL STEEL: ASTM A36/36M 05. 4.7.4. STEEL TUBING: ASTM A500, GRADE B. 4.7.5. WELDED CONNECTIONS: E70XX ELECTRODES, MINIMUM SIZE FILLET WELDS 3/16", AWS CERTIFIED WELDERS. CERTIFICATION PAPERS TO BE SUBMITTED UPON REQUEST. 4.7.6. WHERE STEEL BEAMS ARE CONTINUOUS OVER COLUMNS, PROVIDE WEB STIFFENER PLATES ON EACH SIDE OF THE WEB, OF A THICKNESS EQUAL TO BEAM FLANGE THICKNESS, LOCATED AT THE CENTER LINE OF THE TUBE COLUMN. 4.7.7. THE STEEL FRAME IS "NON -SELF SUPPORTING". ADEQUATE TEMPORARY SUPPORT SHALL BE PROVIDED BY THE CONTRACTOR UNTIL REQUIRED CONNECTIONS OR 4.8. SOIL: ELEMENTS ARE IN PLACE. 4.8.1. MINIMUM SOIL BEARING PRESSURE CAPACITY OF 2000 PSF. FOUNDATIONS HAVE BEEN DESIGNED WITH THE MIN. CAPACITY OF 2000 PSF 4.8. 2. ALL SOIL IS TO BE CLEAN & POISONED FOR TERMITES PER FBC 6th ed. (2017), RESIDENTIAL SECTION R318. 4.8.3. SOIL IS TO BE COMPACTED TO 95% MODIFIED PROCTOR AS DEFINED BY ASTM D 1557-02E01 TERMITE PROTECTION - CONTRACTOR TO USE (1) OF THE TREATMENTS BELOW Borate I Boracore treated lumber Soil Chemical Barrier Method Other treatment - Must specify proposed method and submit documentation, which substantiates the proposed method, is an approved termite protection system or method. OR CHEMICAL SOIL TERMITE TREATMENT IS USED 1. FBC-R R318.1-"A permanent sign which identifies the termite treatment provider and need for re -inspection and treatment contract renewal shall be provided. The sign shall be posted near the water heater or electric panel" 2. Condensate and roof downspouts shall discharge at least V-0" away from the building side walls. 3. Irrigation/sprinkler rinkler systems including all risers and spray heads shall not be installed within T-0" of the building side wall. 4. FBC-R R318.7- To provide for inspection for termite infestation, between wall covering and final earth grade shall not be less than 6 inches. Exception: Paint or decorative cementitious finish less than 5/8" thick adhered directly to the foundation wall. 5. FBC-R R318.1.1 - Initial treatment shall be done after all excavation and backfili is complete. 6. FBC-R R318.1.2 - Soil disturbed after the initial treatment shall be retreated including spaces boxed or formed. 7. FBC-R R318.1.3 - Boxed areas in concrete floors for subsequent installation of traps, etc., shall be made with permanent metal or plastic forms. Permanent forms must be of a size and depth that will eliminate the disturbance of soil after the initial treatment. 8. FBC-R R318.1.4 - Minimum 6 mil vapor retarder must be installed to protect against rainfall dilution. If rainfall occurs before vapor retarder placement, retreatment is required. 9. FBC R R318.1.5 C crete ove and mortar along the foundation perimeter must be removed beore exterlor�s°oiYtreatment. 10. FBC-R R318.1.6 - Soil treatment must be applied under all exterior concrete or grade within V-0" of the structure sidewa Is. 11. FBC-R 13�18.1.6 - An exterior vertical chemical barrier must be install,�d after construction is complete, including landscaping and Irrigation. Any soil disturbed after the vertical barrier is applied, shall be retreated, 12. FBC-R R318.1 - All buildings are required to have pre -construction treatment. 13. FBC-R R318.1 - A certificate of compliance must be issued to the building department by i licensed pest control company before a certificate of occupancy will be issued. The certificate of compliance shall state: "The building has received a complete treatment for the prevention of subterranean termites. The treatment is in accordance with the rules and laws of the Florida Department of Agriculture and Consumer Services". 14. FBC-R R318.6 - After all work is completed, loose wood and fill must be removed from below and within V-0" of the building. This includes all grade stakes, tub trap boxes, forms, shoring or other cellulose containing material. WORST CASE DESIGN PRESSURE TABLE BUILDING DATA WIND SPEED (ULTIMATE) 140 MPH WIND SPEED (ALLOWABLE) 108 MPH WIND EXPOSURE - "C" (FBC-R R301) INTERNAL PRESSURE COEFFICIENT= 0.18 ENCLOSED BLDG) BUILDING CATEGORY = II DESIGN WIND PRESSURE: (COMPONENT AND CLADDING) WORST CASE (10 SF - END ZONE) # END ZONE IS ONLY WITHIN S-O" OF ALL EXTERIOR BUILDING CORNERS WINDOWS AND DOORS 140 MPH + 29.7 PSF / -39.6 PSF (END) U.N.O. CONSTRUCTION + 29.7 PSF / -32.2 PSF (INTERIOR) U.N.O. GARAGE DOORS (V =140 MPH) TYPE: 5B SINGLE 90 +26.3 PSF / -29.8 PSF DOUBLE 16x7 +25.2 PSF / -28.1 PSF NOTE: THE WIND PRESSURES LISTED ABOVE ARE ALLOWABLE PRESSURES. NOTE: IT I THE CONTRACTOR RESPONSIBILITY S S ES ONSIBILITY TO REVIEW DRAWINGS A A WINGS BEFORE CONSTRUCTION BEGINS. FLORIDA DESIGN SOLUTIONS, INC. IS RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF THIS PROJECT ONLY. ANY DISCREPANCY BETWEEN FIELD CONDITIONS, OTHER DESIGN PROFESSIONALS' SHOP DRAWINGS, CONTRACTORS' BUILDING METHODS, AND THESE SIGNED AND SEALED DRAWINGS MUST BE BROUGHT TO THE ATTENTION OF FLORIDA DESIGN SOLUTIONS, INC. PRIOR TO THE COMMENCEMENT OF CONSTRUCTION. NOTE: GYPSUM BOARD MAY BE INSTALLED USING GWB54 NAILS TO SET IN PLACE. FIELD FASTENING SHOULD BE TYPE "W" 1%" DRYWALL SCREWS AT 12" O.C. FOR CEILINGS AND 1%" DRYWALL SCREWS AT 12" O.C. FOR WALLS. ALL ENDS AND EDGES OF WALLBAORD SHALL OCCUR OVER AND BE SCREWED TO SUPPORTS. MAXIMUM SCREW SPACING AT ENDS (EDGES IN VERTICAL APPLICATION) SHALL BE 6" O.C. AT EACH SUPPORT. MINIMUM SCREW / NAIL DISTANCEFROM EDGE SHALL BE /". THIS SHALL APPLY TO BOTH CEILING AND WALL INSTALLATION. DRYWALL SHIMS SHALL BE USED ONLY WHERE NECESSARY. OPENINGS CUT FOR OUTLETS, SWITCHES, ETC, SHALL BE OF A TOLERANCE THAT CAN BE COVERED ADEQUATELY WITH NORMAL SWITCH PLATES AND COVERS WITHOUT ADDITIONAL TAPING OR CAULKING. DRYWALL SHALL NOT BE INSTALLED WITHOUT PROPER BACKING. NOTE: ALL HEADERS BEAMS ETC ARE TO BE SYP #2 OR BETTER AND OR MICROLAM AS INDICATED ON THE DRAWINGS AND CAN NOT BE REVISED. as (D�2 Z fh z�z Q a U1 (D w •U - OLLJ .e E o Lv �E C Cl) C',W �CN _ U"2 v C CD � v Qrn �iQ-o A 1if "°B°° r� LL� C C 1LY....� I. 4 K; W C ram' i LL aQ N Y l W N � ® �✓ ,O � 0 To the best of the Engineer' infpEm do belief, the structural pliindpgd speci ciiii6ns . �cony within these drawings comply"o, Building Code - Residential 6th Edlt+bni cheer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. O O Z (V 0 � � I> --I (n M O re) V) (0 In cn O Q - LL. a F- �M cl� U a 00 Q � � Z W J� v- Mj Z Hn za a� fF O�U 0 L u W yZ Ln � 0�iE8 M 00 rn Ulm 8u`04 ., © L W L LJ Z - > N p � 22 ' Z N CU L / < �` _ 0 a W Z V = U f _ Z N Q i 22 u Z Q u ¢ r W o Z E LU '� Ln .. aLLLL LLJ U N Q Z ~ �z Z Z m o 0 g Uj U0 Lu ,� SCALE : AS NOTED DATE : 3/30/2018 TECH: MJAMES VERSION NO. 10 SHEET NO. SN I ROOF DIAPHRAGM NAILING SCHEDULE RIDGE LINE O, LU 15132" CDX m¢ PLYWOOD OR 7/16" OSB RIDGE LINE 140 MPH (ul03 SECOND GUST EXPOSURE "C" WIND ZONE 140 MPH (ult) 3 SECOND GUST EXPOSURE "C" WIND ZONE 8d RING SHANK NAILS @ 6" O.C. & 8d RING SHANK NAILS @ 6" O.C. EDGES & + + + + + 4" O.C. @ GABLE END WALL OR GABLE TRUSS 8d RING SHANK NAILS @ 6" O.C. INTERMEDIATE 0.113 INCH NOMINAL SHANK DIAMETER 0.113 INCH NOMINAL SHANK DIAMETER RING DIAMETER OF 0.012 OVER SHANK DIAMETER RING DIAMETER OF 0.012 OVER SHANK DIAMETER 16 TO 20 RINGS PER INCH 16 TO 20 RINGS PER INCH 0.280 INCH FULL ROUND HEAD DIAMETER 0.280 INCH FULL ROUND HEAD DIAMETER 2 INCH NAIL LENGTH 2 INCH NAIL LENGTH NOTE: FOR 8d RING SHANK NAILS 0.113x 2x 3/8" RING SHANK COIL GUN NAILS MAY BE USED 1) SEE STRUCTURAL NOTES FOR SHEATHING SPECIFICATIONS AND WIND SPEED. 2) END JOINTS OF THE ROOF SHEATHING SHALL BE STAGGERED AND OCCUR OVER FRAMING MEMBER. 3) SCHEDULE ASSUMES SHEATHING IS FASTENED DIRECTLY TO SOUTHERN YELLOW PINE OR DOUGLAS FIR OR BETTER, IF ROOF FRAMING CONSISTS OF A LESSER GRADE OF LUMBER, CONTRACTOR MUST CONTACT ENGINEER OF RECORD FOR ALTERNATE NAILING PATTERN. + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + q + + + + + + + + + + + + + + + + + + + + + + + + + + +� + + + + + + + + + + + + + + + + 4 + + + + + + + + + + + + + + + + + + + + + + + + + + + + 6'1 + + + 6'-0" + + + + + + + + +++ +++ + + + + + + + + + + + + + + + + + +++ +++4 + + + + + + + + + _ + + + + + + + + + + + + + + + + + + + + + + 1 0 + + + + + + + + + + + + + + + + + + + + + + io + + + + + + + + + + + + + + ++ +++ ++++++++ + Backer and Filler Block Dimensions BCI®Joist Backer Block Series Thickness Filler Block Thickness 3/4" or 7/8" 5000s 1.8/1.7 wood panels Two 3/4" wood anels or 2 x _ P 1-1/8" or two 1/2" 6000s 1.8/1.7 wood panels 2 x _ + 5/8" or 3/4" wood panel 1-1/8" or two 1/2" 6500s 1.8/1.7 wood panels 2 x _ + 5/8" or 3/4" wood panel 1-1/8" or two 1/2" 602.0 wood panels 2 x _ + 5/8" or 3/4" wood panel 902.0 2 x _ lumber Double 2 x _ lumber DOUBLE JOIST CONSTRUCTION (Not required if both loaded equally from above) Filler blocking r / 1/8" gap t FILL CELL w C> STD. 90° CONT. #5 HOOK BAR STD. 90" HOOK BOND BEAM SIMPSON MGT w/ (22)10d NAILS TYR GIRDER TRUSS CONT. #5 BAR 2X TOP PLATE 5/81 #5 CONT. THRU FROM BOLT FOUNDATION TO HIGHEST ----1W BOND BEAM STEP SCALE: N.T.S. 2nd FLOOR INTERIOR/EXT WALL SEE PLAN FOR MORE INFO CONT. BASE PLATE BEARING COLUMN SEE PLAN FOR REQ'D PLYWOOD FLOOR COLUMN AND SHEATHING PER PLAN CONNECTION TJI TO BE CUT TO ALLOW FOR BLOCKING/TJI MASONRY WALL OR INTERIOR BRG. WALL TJI PER PLAN OTHERWISE SOLID BLOCKING TO MATCH Solid block all posts from # OF 2nd FLOOR above to bearing below. STUDS SECTION @ INT. BRG. WALL N.T.S. 1/8" min. Small 2" max ) gap ?min. • � 4 max. Q Clinch nails when possible A 1) Support back of web during nailing to prevent damage to web -flange connection. 2) Block solid between joists for full length of span. Tight fit 3) Leave 1/8" gap between top of filler blocking and bottom of top flange. 2x4/Plywood/OSB web stiffener 2" min. 4) Place joists together and nail from each side with 2 rows of 10d nails required when indicated or 4" max. 2x_: CONTRACTOR TO PROVIDE 2x TO FILL THE HEIGHT at 12" o.c., clinched when possible. Stagger rows from opposite -Hangers with side nailing. OF THE JOIST ASA REQUIRED LEAVING �" GAP @TOP sides by 6". - Hangers with sides not containing WEB STIFFENER top flange of joist. DOUBLE JOIST CONNECTION - Birdsmouth cuts. N.T.S. - Under 2nd floor column w/ loads N.T.S. higher th-- 11;f nik SQUASH BLOCKS AT INTERIOR BEARING Vertical load transfer =1900 plf max along load bearing wall. Load bearing wall must stack *Non -stacking walls over squash=20 blocks and require additional wall or beam below.* consideration. Check local building code for appropriate 1l16" details in One 10d box areas=20 of high or=20 sinker lateral load. nail each side 10 t, -0 at bearing. TANK -LESS W/H CORNER OF HOME H C G GARAGE SIDE O O O 5'-0" Q - c� STUB -OUT FOR O 1'-0" o o ;� GAS METER o (V = • MEASUREMENTS ARE FROM FINISHED FLOOR • ROUGH -IN GAS TO RIGHT (ALWAYS) - 12" OFF -CENTER • ROUGH -IN ELECTRIC TO LEFT (ALWAYS) - 12" OFF -CENTER GAS CONNECTION DETAIL "ONLY APPLIES TO HILLSBOROUGH AND PASCO COUNTY" RAFTER SPAN TABLE MEMBER SIZE AND SPACING MAXIMUM LENGTH MEMBER CONNECTIONS* 2" X 4" @ 16" O.C. 7'-5" (2)16d TOENAILS 2" X 6" @ 16" O.C. 1011 (2)16d TOENAILS 2" X 8" @ 16" O.C. 13'-9" (3)16d TOENAILS 2" X 10" @ 16" O.C. 16-5" (1) SIMPSON HTS20 OR (3)16d TOENAILS 2" X 12" @ 16" O.C. 19'-3" (1) SIMPSON HTS20 OR (4)16d TOENAILS 2" X 4" @ 24" O.C. 6-1" (2)16d TOENAILS 2" X 6" @ 24" O.C. 81-6" (2)16d TOENAILS 2" X 8" @ 24" O.C. 11'-0" (2)16d TOENAILS 2" X 10" @ 24" O.C. 13'-0" (3)16d TOENAILS 2" X 12" @ 24" O.C. 1514" (1) SIMPSON HTS20 OR (3)16d TOENAILS * TOENAIL CONNECTIONS DESIGNED FOR SHEAR ONLY (i.e. RAFTER TO RIDGEBEAM). ** SOUTHERN YELLOW PINE, 55 PSF LOADING Squash block (2x4 minimum) Bearing wall, Versa -Lam LVL or Glulam Beam Boise Joist Blocking l IsP T' /10d1 nails at W inr._ Q�'/ Provide adequate bearing for each lapped joist. Odnails SECTION @INT. BRG. WALL N.T.S. MINIMUM SPACING = 2x GREATEST KNOCKOUTS) ALLOWED DIMENSION OF LARGEST HOLE IN BEARING ZONES D (KNOCKOUT EXEMPTS) (see table below) D (see table below) DO NOT cut, notch or drill flanges BLOCKING PANEL, INTERIOR Vertical load transfer =1900 plf max. along bearing wall Required on interior walls : - for vertical load transfer when load bearing - for lateral support when joists meet over wall, or wall stacks directly over wall or Web Stiffener Fastener Schedule Joist _aring Location Series ,apt e th I End Intermediate ® BC15000s 9-1/2" 2-8d 2-8d 11-7/8" 2-8d 3-8d 14" 1 2- BCI 6000s® BCI6500s® 9-1/2" 11-7/8" 2-8d 2-8d 2-8d 3-8d 14" 2-8d i 5-8d 16" 2-8d 6-8d BCI61 11-7/8" 2-8d 3-8d 14" 2-8d 5-8d 16" 2-8d 6-8d BCI90s® 11-7/8" 3-16d 3-16d 14" 5-16d I 5-16d 16" 6-16d 6-16d LC SIMPS( w/ (22) NAILS 1 TYPICAL SIMPSON MGT TO BUILT-UP COLUMN DETAIL TYPICAL SIMPSON LUS/HUS/HUC INSTALLATION MIN. EMBEDMENT SCHEDULE FOR _ AND QUANTITY )F FASTENERS TYPICAL SIMPSON HETA20 / Plumbing HETAL20 INSTALLATION beam below Load bearing wall must stack over blocking and wall or beam below.* Joist 1-When joists meet over wall, provide 1 3/4" minimum bearing for each. I -Joist can be offset Use 10dx3" nails at 6"o.c. for all joist blocking panel *Non -stacking walls require additional consideration. — • ■ • ■�I .73 6"A 1 " ROUND HOLE MAY 6n 6„ DO NOT CUT HOLES BE CUT ANYWHERE IN CANTILEVER LARGER THAN 1Y" THE WEB. PROVIDE AT OUND IN LEAST 3" OF CLEARANCE CANTILEVERS. FROM OTHER HOLES MINIMUM DISTANCE FROM SUPPORT, LISTED BELOW, IS REQUIRED FOR ALL HOLED GREATER THAN 1Y" NOTES: 1. JOISTS MUST BE PROPERLY DESIGNED TO MEET BUILDING CODE REQUIREMENTS. 2. TABLE IS FOR UNIFORMLY LOADED MAXIMUM LOADS OF 40 PSL(LIVE) AND 15 PSF (DEAD) ON SIMPLE SPAN APPLICATIONS ONLY. 3. REFER TO JOIST SPECIFIER GUIDE FOR INSTALLATION AND OTHER INFO. 4. SELECT A TABLE ROW BASED ON JOIST DEPTH AND THE ACTUAL JOIST SPAN ROUNDED UP TO THE NEAREST TABLE SPAN. SCAN ACROSS THE ROW TO THE COLUMN HEADED BY THE APPROPRIATE ROUND HOLE DIAMETER OR RECTANGULAR HOLE SIDE. USE THE LONGEST SIDE OF A RECTANGULAR HOLE. THE TABLE VALUES IS THE CLOSEST THAT THE CENTERLINE OF THE NEAREST SUPPORT. 5. THE ENTIRE WEB MAY BE CUT OUT. DO NOT CUT THE FLANGES. HOLES APPLY TO EITHER SINGLE OR MULTIPLE JOISTS IN REPETITIVE MEMBER CONDITIONS. 6. FOR MULTIPLE HOLES, THE AMOUNT OF UNCUT WEB BETWEEN HOLES MUST EQUAL AT LEAST TWICE THE DIAMETER (OR LONGEST SIDE) OF THE LARGEST HOLE. 7.1i2" ROUND KNOCKOUTS IN THE WEB MAY BE REMOVED BY USING A SHORT PIECE OF METAL PIPE AND HAMMER. 8. HOLES MAY BE POSITIONED VERTICALLY ANYWHERE IN THE WEB. THE JOIST MAY BE SET WITH THE %" KNOCKOUT HOLES TURNED WITHER UP OR DOWN. 9. THIS TABLE WAS DESIGNED TO APPLY TO THE DESIGN TO APPLY TO THE DESIGN CONDITIONS COVERED BY TABLES ELSEWHERE IN HIS PUBLICATION. USE THE BC CALC SOFTWARE TO CHECK OTHER HOLE SIZES OR HOLES UNDER OTHER DESIGN CONDITIONS. IT MAY BE POSSIBLE TO EXCEED THE LIMITATIONS OF THIS TABLE BY ANALYZING A SPECIFIC APPLICATION WITH THE BC CALC SOFTWARE. HOLE CUTTING CHART N.T.S. up to 3" to avoid vertical plumbing 3" max JOISTS OFFSET N.T.S. Joist hanger A/C CHASE 4" PVC SLEEVE THRU STEM WALL Backer block (12" wide min.) Nail with 10-10d nails. Install tight to top flange. SLEEVE THRU STEM •. SEE PLAN FOR °• 4 . • FOUNDATION INFO ` d' STEM FOUNDATION \\ --�N Filler block. Nail with 10-10d nails. Backer block required where top mount hanger load exceeds 250 lbs. Install tight to top flange. 1/4"1 gap Backer Block "Top Mount" "Face Mount" Backer block shall be tight Backer block shall be tight to bottom of top flange with to top of bottom flange with 1/4'1 gap at top of bottom 1/4'1 gap at bottom of top flange. flange. eb sti uiredffner as Web stiffeners are not required when top reqif hanger flange is laterally supported by joist hanger. doesn't meet height requirements 0.6 X Joist p depth I -JOISTS BUCKETS N.T.S. 1 A/C CHASE 4" PVC (2) #5 REBAR SLEEVE THRU FOOTING MONO FOUNDATION TYP. FND. PENETRATIONS SCALE: N.T.S. SIMPSON HETA20 / HETAL20 INSTALLATION @ MID SPAN NOTE: UPLIFT VALUE IS BASED ON S.P.F. LOCATION OF SECOND H10A SIMPSON H10A ° ° (WHEN w/ (18)10d x 1 1/2" ° REQUIRED) NAILS UPLIFT =1015# TYPICAL SIMPSON H10A INSTALLATION TYPICAL SIMPSON MTS / HTS INSTALLATION TOP (2) #5's x 4'-0" CENETERED @ PIPE PENETRATION 12" BELOW GRADE PLUMBING LINE PVC OR SCH40 SLEEVE a SEE FND. PLN. SIZE & REINF. PIPE VERTICAL THRU FND. TOP (2) #5's x 4'-0" PVC OR SCH40 SLEEVE CENETERED @ PIPE PLUMBING LINE PENETRATION q d 4 d SEE FND. PLN. SIZE & REINF. PIPE PERPENDICULAR TO FND. TOP (2) #5's x 4'-0" PVC OR SCH40 SLEEVE CENETERED @ PIPE PENETRATION PLUMBING LINE 4 4, e d d da G s d a. Q I_ .v SEE FND. PLN. SIZE & REINF. (D zo z�z a U) z C2 V') U' +—� LU 0 LU E o 0 U W E $ aMp C',F- C,— O o c = U �' � L rU_00 o `Oti o 0 Quern v o B D• 8 V- Z 5 C' ch J �s o To the best of the EllneerS, owled�b, Ri orma p , an¢, belief, the structural pl" an dP3 $4iap tine�\\!� within these drawings c6iiwih`thE 2O1�F7orid ��\�• Building Code - Residential ti h En signature and is for thA Fb ii eering seal only portions of the drawing pages bearing Engineer's signature and seal. O ON Z �Ii OCD z iun /-i M O M <C U0 'gyp 0-N 'L 2: (A 0 < N LL ilk CL ^ fa Z W J d' J z w� �a H Wair� Q1=ZOU Z•WzQ S z Z �_3 oQ. 2$ 00 "8�® iM N LU ? o z Lin O _ _ Icr z Lu _ I' W X ou N � J Z QQua o ao WJ_ W J Ln r-1 6i Q tJJ Z *k � Z z _ 1�� z 0 00 ri .-i 0- to SCALE : AS NOTED DATE : 3/18/2018 TECH: FFLORES VERSION NO. 10 SHEET NO. SN 1 FOR UNDERLAYMENT REQUIREMENTS SEE R905. 12 VARIES / 5/8" OR 1/2" HIGHS' STRENGTH CEILING BOARD PER CODE (OR 5/8" GYP. TYPE "X" @ GARAGE W/A HABITABLE ROOM ABOVE) W/DRYWALL SCREWS @ 7" O.C. CEILING & 8" O.C. WALLS INSULATION PER —� CHART ON FLOOR / PLAN J/ 1x2 P.T. HORIZONTAL NAILER STD. 90'HOOK (SEE DETAIL (1) LAYER TYPE II (#30) UNDERLAYMENT FOR ROOF PITCH > 4:12 (2) LAYERS TYPE I OR TYPE II (#15 OR #30) UNDERLAYMENT FOR ROOF PITCH 4:12 OR LESS. PRE ENGINEERED WOOD TRUSS @ 24" O.C. U.N.O. HURRICANE ANCHOR @ EACH TRUSS (SEE UPLIFT SCHED.) W/ METAL PL. UNDER EA. TRUSS MOISTURE BARRIER SHINGLE ROOF 7/16" O.S.B. MIN. SEE ROOF NAILING SCHEDULE ON SHT. SN1 — ELEV. VARIESjdk ALUMINUM DRIP EDGE ALUMINUM FASCIA N.O. 2x SUB FASCIA EE SOFFIT SHEET 8"x8"X16" KNOCK -OUT BLOCK W/ 1#5 CONT. FILLED SOLID W/GROUT �8" C.M.U. TYPICAL TYPE "S" MORTAR ARCHITECTURAL �FINfSH 1x2 PT WD FURRING @ 24" O.C. 1/2" GYPSUM WALLBOARD (1) #5 VERT. IN FILL CELLS (SEE U.N.O. FOUNDATION PLAN FOR LOCATIONS) 1x4 P.T. BASE NAILER 4"x4" INSPECTION 31/4" BASEBOARD PORT AT EACH FILLED CELL TYPICAL MIN. 2500 PSI CONC. SLAB co AT GARAGE CONTRACTOR MIN PSI MAY VARY PER TO CUT BLOCK OR POUR MUNICIPALITY. CURB DUE TO SLOPE NCRETE SLAB W/ 6X6 COIBERMESH' �- NOTE: EXTEND WWF OR DECO FINISH 4" to 6" "FIBERMESH' "F BELOW GRADE v N p° a _Z ° °Q 6 MIL VAPOR BARRIER D r COMP. SOIL. p (COMPACTED TO 95% MODIFIED PROCTOR — ASTM D1557) 3" MIN. CLR. (2) #5 REBAR CONT. ON 3" CHAIRS TYP. 4" 11-411 STD. 90 HOOK (SEE U.N.O. DETAIL) TYPICAL WALL SECTION rA SCALE: 3/4" = V-0" S3 OPT: DEPRESS SLAB 5Y2" DEEP AND 6" BEYOND DOOR TO RECEIVE PAVERS / DRIVEWAY CONCRETE SLAB PAVERS SEE A/S3 OR J/S6---IL FOR REINF. INFO. 3" MIN. CLEARANCE 1'4" (1 STOR ) / V-8" (1 STORY w/ DEPRESSED SLAB OPT.) 1' 8" (2 STOR ) GARAGE DOOR SLAB RECESS ri1 SEE TYP. WALL SECTION FOR SCALE: N,T.S. S3 ADDITIONAL INFORMATION. BLOCK WALL BEYOND 14' jl J�O.H.D. RECESS = �z I�- h— ►,�is 2x #2 SPF STUDS - @16" O.C. W/ (2) 16d TOENAILS T & B 2x P.T. PLATE (2) #5 CONT. ON 3" CHAIRS (TYP.) ���11-111AA-mg,°. (1) ROW 2x BLOCKING @ MID HGT. FOR WALL HGT. <- 8'-6". (2) ROWS 2x BLOCKING @ 3rd PTS FOR WALL HGT. > 8'-6". 1/2" GYP. WB (MIN.) @ GARAGE SIDE IF Z APPLICABLE. 1/4" DIA. X 31/4" TAPCONS @ 24" O/C & @ 6" MAX FROM END OF 2 x PLATE -E 6x6W1.4xW1.4 tV Q WWF OR FIBERMESH i�lle'2111111[11 = 8" TYPICAL INTERIOR BEARING WALL W/OUT UPLIFT GG SEE TYP. WALL SECTION SCALE: 3/4"=V-0"QS3 FOR ADDITIONAL SLAB INFORMATION. 8"x8"x16" NOMINAL BLOCK WITH 3/8" MORTAR BETWEEN COURSES GARAGE SLAB AT STEP SCALE: 3/4"=V-0" 2x S.P.F. STUDS @ 16" O.C. 2x STUD LOAD BEARING OR EXTERIOR WALL 8" C.M.U. 1"x P.T. STUD #5 VERT. IN FILLED CELL SEE CC/S3 OR N G/S3 FOR ANCHOR BOLT INFO. 5/8"x6" "J" BOLTS BOLT (IF NO UP LIFT ON @ 24" O.C. VERT. OR WALL SEE GG/S3) 5/8" x 6" EPDXY BOLT OR (6)1/4"x31/4" TAPCONS *SIMPSON SP1 SPACED EVENLY wl (10)10d NAILS r 2x P.T. PLATE �,P ASSUMED FINISHED GRADE MONO OR STEMWALL Z ° FOOTING MONO SHOWN o p p FOR CLARITY ° 00 _ _ _ _ _ _ ° p p P ° o ° I —III —III —III —III —III i III —III —III —III —III —III- ? p D ° NOTE: a IIIIIIIillllllllllllllllllilllllll�� N *FOR BEARING WALL = I=III=111=1 I� III l W/ UPLIFT ONLY I I I=1 11=1 11=1 11=1 11=III=1 11=1 11=1 11=1 I I=I 11=III=1 III ;,, I I I, 11=1 11=1 11=1 11=1 11=1 11=1 11=1 11=1 1 I I-III=1 I I=1 I �� 11=1 11=1 11=� � ,III-1 =III-III.-I�I�I11�11111�1��1�11111�1���1�1 III,-III-�I� FRAME WALL TO C.M.U. WALL CONNECTION D SEE TYP. WALL SECTION FOR ADDITIONAL SCALE: 3/4"=V-0" S3 SLAB INFORMATION. 6x6W1.4xW1.4 31/2" WWF OR FIBERMESH min. 4" ° ' GRADE <v 00 _ _%. LL�i_ 010� (1) #5 REBAR w/ OPT. MIN. TYPICAL THICKENED SLAB EDGE L SCALE:3/4"=V-0" S3 EXPANSION JOINT N M SEE A/S3 OR J/S6 FOR REINF. INFO. BLOCK WALL BEYOND O.H.D. RECESS 3" MIN. CLEARANCE GARAGE DOOR SLAB RECESS SEE TYP. WALL SECTION FOR SCALE: N.T.S. S3 ADDITIONAL INFORMATION. 1/2" OR 7/16" OSB MIN. PLYWOOD SHEATHING — NAILED W/ 8d COMMON NAILS @ 4" O/C BOUNDARIES, 6" O/C EDGES, AND 12" O/C FIELD. SHEAR WALL REQUIRES 2x BLOCKING @ SEAMS. (2) ROWS OF 2x BLOCKING @ THIRD POINTS 5/8"OR 1/2" HIGH STRENGTH (U.N.O.) (OR %" GYP. TYPE "X" @ GARAGE W/A HABITABLE ROOM ABOVE) S.P.F. DOUBLE TOP PLATE SIMPSON SP2 w/ (12)10d NAILS 1/2" CDX PLYWOOD OR 7/16" O.S.B. SHEATHING REQ'D. FOR ALL EXTERIOR OR SHEAR WALLS AS INDICATED ON THE PLAN. ATTACH SHEATHING W/ 8d COMMON NAILS @ 4" O.C. @ BOUNDARIES, 6" O.C. @ 3/8" MORTAR BETWEEN EDGES, AND @ 12" O.C. @ FIELD SLAB & BLOCK 5/8"" x 10" "J" BOLT @ 24" O.C. W/ 2""x3/16" PLATE WASHER (TYP.) ELEV. 0'-0" (ALT: 1/2"xl2" TITEN HD @ 24" AK O.C. OR 5/8"x10' WEDGE ANCHOR @ 24" O.C.) 211 A.F.F. 0 z 31/2"MIN. ELEV. 4-3 1/2" A.F.F. p p. e N ° e ;0 p •. TRUSS BOTTOM CHORD OR 2x4 BLOCKING TRUSS BOTTOM CHORD OR 2x4 BLOCKING w/ w/ (2)16d TOE NAILS @ EACH END 5/8„ OR 1/2 HIGH STRENGTH (U.N.O.) (OR / GYP. TYPE "X"@ (2)16d TOE NAILS @ EACH END SEE UPLIFT SCHEDULE FOR UPLIFT GARAGE W/A HABITABLE ROOM EE UPLIFT SCHEDULE FOR UPLIFT CONNECTIONS. PROVIDE (1) SIMPSON SP1 w/ ABOVE) CONNECTIONS. PROVIDE (1) SIMPSON SP1 w/ (10) 10d NAILS WHEN TRUSS ALIGNED WITH S.P.F. DOUBLE (10)10d NAILS WHEN TRUSS ALIGNED WITH STUD BELOW TOP PLATE STUD BELOW 2"x S.P.F. (OR EQUAL) STUDS @ 16" O.C. U.N.O. SIMPSON SP2 w/ 2"x S.P.F. (OR EQUAL) STUDS @ 16" O.C. (12)10d NAILS U.N.O. (1) ROW 2x BLOCKING @ MID HGT. FOR WALL 1) ROW 2x BLOCKING @ MID HGT. FOR HGT. < V-6". (2) ROWS 2x BLOCKING @ 3rd PTS WALL HGT. < 8'-6". (2) ROWS 2x BLOCKING FOR WALL HGT. > 8'-6". @ 3rd PTS FOR WALL HGT. > 8'-6". INSULATION PER CHART ON FLOOR PLAN NSULATION PER CHART ON FLOOR PLAN 31MPSON SP1 w/ (10)10d NAILS SIMPSON SP1 w/ (10)10d NAILS 2x P.T. BOTTOM PLATE 2x P.T. BOTTOM PLATE 6x6W1.4xW1.4 6x6W1.4xW1.4 WWF OR FIBERMESH 2„ / WWF OR FIBERMESH IG-y11 ii-Alp-I,�III� ::1ICCI ��II'�Il-l�Ilryll. • "SHEAR WALL" SCALE: 3/4"=V-0" 11EID GAR eGs_ 000��N�° S -2x STUDS @ 16" O/C G ISULATION PER CHART ON FLOOR PLAN 7/8" STUCCO FINISH PER ASTM C. 926 APPLY 3 LAYERS W/ TOTAL THICKNESS 7/8" OVER 5/8 x 10 J BOLT @ 24 O/C W/ 2 X 3/16 METAL LATH. FIRST 2 LAYERS 3/8" THICK H. CONTINUOUS TO FOOTER BELOW 90 HOOK DETAIL ��" n n n a ��" " PLATE WASHER TYPICAL 3RD LAYER 1/8" THICK. @ K.O. BLOCK 9v IMPSON SP1 w/ (10)10d NAILS @ EA. STUD MIN. 2500 PSI CONCRETE SLAB W/ 6 x 6 W1.4 x W1.4 WWF OR 2X P.T. PLATE 20" MIN. LAP [24" MIN. LAP] #5 REINFORCING FIBERMESH WEEP SCREED INSTALLED BAR EE PER MANUF. #3 OR #4 REINFORCING BAR N • ° . ° Z_ #3 & #4 LAP SPLICE GRADE 40 MIN. F - 40ksi FINISH GRADE O0 60ksi] [GRADE 60 MIN. Fy=60 25"MIN. LAP [30"MIN. LAP] 6 MIL VAPOR BARRIER C ° e A. —� #5 REINFORCING BAR ° _ &S I AP SPI IrF 11= 115111112 11L�7111 IIlg4�lg Jgg, J SEE TYP. WALL SECTION FOR ADDITIONAL SCALE: 3/4"=V-0" SLAB INFORMATION. P.T. 2x 1/2" GYP. BD. " HOLD GYP. BD. 1/2" FROM SLAB 0� J CONT. BEAD SEALANT d a INTERIOR -3 1/2" d c q� CONCRETE NAILS W 1 1/2' EMBEDMENT @ 12" O.C. STAGGERED, FROM BOTTOM PLATE TO CONCRETE (MIN. SHEAR 180# MIN. TENSION 120#) CONCRETE SLAB °d i0 S C N" 1=1Ti= 1—_ M 6 MIL VAPOR BARRIER -III=1 I -I I -III=11I 4" 4" INTERIOR WALL SLAB STEP NON-BRG. SCALE: 3/4"=V-0" —2X STUDS @ 24" O.C. U.N.O. GARAGE �'1/2" GYPSUM WALLBOARD U.N.O. W/ DRYWALL SCREWS @ 8-O.C. —INSULATION PER CHART ON FLOOR PLAN CONT. BEAD SEALANT E d. 6x6W1.4xW1.4 WWF OR FIBERMESH r, K S3 NOTE: SEE SECTION C/S3 FOR ADDITIONAL INFORMATION SIMPSON SP1 w/ (10)10d NAILS 2x P.T. PLATE SPACE ANCHOR BOLTS 6" MAX FROM w END OF 2" x PLATE o ° U . A. � m. a t w �— p U) — - (2) #5 CONT. ON 3" CHAIRS 8" 1'-4" (TYP ) (1) ROW 2x BLOCKING @ MID HGT. FOR WALL HGT. s 8'-6". (2) ROWS 2x BLOCKING @ 3rd PTS FOR WALL HGT. > 8'-6". 1/2" GYP. WB (MIN.) @ GARAGE SIDE IF APPLICABLE. E 6x6W1.4xW1.4 = WWF OR FIBERMESH p n. . . =11 1-2 - �lli Ildlhll' 8- 10" #6 REINFORCING BAR #5 STD. 90 HOOK #6 LAP SPLICE TYPICAL INTERIOR BEARING REBAR DETAILS rF WALL W/ UPLIFT rG SCALE: N.T.S. S3 SCALE: 3/4"=V-0" S3 SEE PLAN 1 1/2" RECESS FOR A I 6 x 6 W1.4 x W1.4 FRAME -DOWN FALSE BEAM w/ (3) SEE ROOF PLAN S.G.D. (U.N.O.) WWF OR FIBERMESH N_ c 10d NAILS TO TRUSS TOP CHORD FOR TRUSS M E AT 24" O.C. MAX. CONNECTION INFO SEE PLAN FOR &LAYOUT DESIGN 4 TOP OF BEAM a FM SEE ROOF PLAN c °. " .e p 0 S E- — F R TRUCTURAL � • v BEAM SIZE & % I 4' a CONNECTION INFO Cl) ° 8 i I — i 2x4 #2 SYP P.T. FRAMING w/ MIN 7/16" O.S.B. SHEATHING SEE A/S3/J/S6 I I8" zO ATTACHED PER NAILING FOR REINF. INFO. OPTION #1 w j SCHEDULE SEE TYP. WALL SECTION FOR ADDITIONAL al SLAB INFORMATION. FOR SEEORAL oLAN W STRUCTTUCOLUMN SIZE SLAB STEP & RECESS S.G.D. M fn & BASE CONNECTION INFO. SCALE:3/4"=V-0° S3 SEE DETAIL 16/D1 FOR SECURE 2x4 P.T. BTM. PLATE COLUMN TO PORCH SILL w/ 1/4"x3" TAPCONS AT 8" O'C' MASONRY WALL AND ATTACHMENTS & 18/D1 PAD FOOTING FOR COLUMN TO BEAM TRIM PER PLAN 8" MASONRY WALL ATTACHMENTS EXTEND FILL CELLS c TO FOUNDATION PAD SQUARE CMU BLOCK BASE, CONT. FOOTING STEEL MAT REINFORCING. SIZE VARIES PER PLAN M w/ MIN. (2) #5 VERTICALS 00 a d —j FILLED SOLID (SEE PLAN FOR = T_F=1 I 1_ _ ° _ a SIZE AND REINFORCEMENT) c7 1=1 I ° d•= 1=1 I = 1-1' =III=1 z W o —III— I1=1I 11=1I1=1 —I I —III ul Z BRICK PAVERS or SLAB PER Lou W �j o = =1 = • • °• _— —_—_ Z e / COMMUNITY SPECS " �; — — — — -- "' ¢ 0-0 FIN. FLR.jk `�i �i o`o; � � 'ii %i ;` is . . • -- 6 r -I -i -I I I -I I I-I4 11 -I11=111 w 1I I 1 1-I 1-I 1-I 11-I I I I=1 1=1 I= FOOTING BEYOND PAD REINFORCEMENT -� 1=1 1=i—"' (SEE SCHEDULE) 3" MIN. CLEARANCE FOOTING WIDTH SEE SCHEDULE )LUMN FTG. DETAIL N SCALE: N.T.S. S3 z� —o z�z a z 0 to 0 w 0 "' _ E /') tNvie o U M ch W ~ C N M O - U co 8Qt; ¢ rn 0 S o B D.10 • ���i�fr�� �j J �1 m i� LL = a �-` ti V LL! tj �• m To the best of the Engiiregr'd knovQ�gBtr,��ka ion ; belief, the structural pldrfsppf specilTeations con within these drawings comply 'yiAth tpe,{Q9�'tp' Building Code • Residential 6th MA120 Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. O Z NO 0 W N -4 (n M 00 M QM-mvLn a. VI •� d' L_ L Ln a , U� a� Q � � W Z J � J oz 2 Qa f� I— �Q�d 0 V2z V • (ON LU 0 J ��® Z82 M w � Ln z In 3 II--LUf z UO _ 89 ' O — . US 0�� U0 zW N N �' Wz� arxo Q Z h ��� Z LU Ln w d Q Z~ N T Z 91 coZ O LLj LU e-� CL V) SCALE : AS NOTED DATE : 3/18/2018 TECH: FFLORES VERSION N0. 10 SHEET NO. S3 12 \Np) SEE ELEV. SIMPSON SP2 w/ (12)10d NAILS AT EACH STUD CRICKET AS REQUIRED SINGLE 2x CONT. BASE (2) 2x6 OR (2) 2x8 TOP PLATE SEE PLAN (2) 2x HEADER TO SIT 2x6 / 2x8 WALL BEYOND FLUSH TO THE OUTSIDE SEE PLAN FOR HEADER SEE PLAN FOR SIZE CONNECTION 2x DEAD WOOD @ MID POINT w/ (3)12d DOUBLE 2x TOP TONEAILS SPACED EVENLY PLATE —� 2x BLOCKING @ EACH END W/ 10d @ 4" O.C. FROM EACH HEADER FACE TO BLOCKING (2) 2x HEADER PER PLAN VARIES 2x BOTTOM PLATE W/ (1)10d @ 8" O.C. TO EACH HEADER FACE 2 x6 (MIN.) FRAME WALL HEADER DETAIL SCALE: N.T.S. S4 SEE TYPICAL WALL SECTION PRE-ENGINEERED WOOD TRUSSES @ 24" O/C UPLIFT CONNECTOR (SEE SCHEDULE) DOUBLE 2x4 SPF. #2 TOP PLATE 2x S.P.F. STUDS @ 16" O.C. SINGLE 2x CONT. TOP PLATE W/ (2)12d INTO TRUSS ABOVE 2x CLOSURE WALL W/ STUDS @ 16" O.C. W/ (3)10d TOENAILS T&B AS REQ'D 2x BLOCKING @ MID POINT EVERY OTHER + + STUD W/ (3)10d NAILS PLATE W/ (2)16d TO TRUSS BELOW 101 1/2" EXTERIOR GRADE SHEATHING FASTENED TO TRUSSES WITH 8d COMMON WIRE NAILS @ 4" O/C BOUNDARIES 6" O/C EDGES & 8" O/C FIELD SIMPSON SP1 w/ (10)10d NAILS AT EACH STUD 2x P.T. PLATE 5/8" x 10" "J" BOLT @ 24" O/C MAX W/ 8" EMBEDMENT 8"X8"X16" K.O. BLOCK W/ 1 #5 CONT. AND FILLED SOLID W/GROUT 1 #5 VERT. IN CONC. FILLED CELL W/ STD. 90^ HOOK IN K.O. BLOCK KNEE WALL ABOVE MASONRY WALL DETAIL MOUNTING BASE NOT SHOWN FOR CLARITY SEE DETAIL K/S4 SEAT FOR BLOCK IS POURED IN PLACE CONCRETE GARAGE FLOOR SLAB TROWEL FINISH SEE GENERAL NOTES SLOPE FORWARD FOR DRAINAGE BLOCKING (TYP.) L-ROOF TRUSS UPLIFT CONNECTOR (SEE SCHEDULE) MOISTURE BARRIER SCALE: N.T.S. SEE PLAN FOR FOOTING DIMENSIONS GARAGE ENTRY FINISHED MASONRY DETAIL SCALE: N.T.S. 1/2" MINIMUM CEMENT FINISH STANDARD 3" DIA. TEE THREADED 3" DIA, EXTENSION, SCREW OFF CAP (3" DIA.) FOR CLEAN -OUT MIN. EXTENSION FROM EXTERIOR FACE OF BLOCK WALL IS 1 1/2" MAXIMUM EXTENSION FROM EXTERIOR FACE OF BLOCK WALL IS 21/4" VENT OR 2ND FLOOR TYPICAL C.M.U. WALL 3/4" FURRING STRIPS 1/2" GYPSUM BOARD W/ DRYWALL SCREWS @ 8" O.C. OR 4d DRYWALL NAILS DRAIN WALL CLEAN -OUT rA SCALE: N.T.S. S4 REFER TO WINDOW PRODUCT APPROVAL SHEETS FOR INSTALLATION INFORMATION BY MANUFACTURER. TYPICAL SECTION THRU WINDOW ' NOTCH LINTEL WHERE REQUIRED BLOCK W/ (1) #5 FOR CONCRETE PLACEMENT G G O d 7 8" STD. 9d"HOOK 8 LINTEL BEAM W/ (1) #5 CONT. IN OPENINGS GREATER THAN 6'-0" WIDE (U.N.O. ON PLAN) OPENING FILLED CELL WI (1) #5 VERTICAL SEE FDN. PLAN FOR LOCATION NOTES: 1� FILL LINTEL AND ALL CELLS ABOVE LINTEL. NOTE: FOR BEAM DEPTH 22", PROVIDE A 4" x 4" INSPECTION PORT @ EACH VERTICAL REBAR & DIRECTLY ABOVE THE LINTEL. Q VERIFY THAT ALL REINFORCEMENT HAS BEEN PLACED PROPERLY. O3 SEE FLOOR PLAN FOR ADDITIONAL INFORMATION. ® OPENINGS LESS THAN OR EQUAL TO 6'-0" IN WIDTH DO NOT REQUIRE ADDITIONAL STEEL REINFORCEMENT UNLESS NOTED ON FLOOR PLAN. TYPICAL FILLED LINTEL ASSEMBLY SCALE: N.T.S WIDTH OF OPENING VARIES 4" FORM CONCRETE INSET TO 1l2"X91/2" PLYWOOD CREATE A SOLID BASE FOR BLOCK WALL ABOVE. SCRAP MATERIAL MOUNTING BASE SHOWN IN POSITION -2x6 MOUNTING BASE G S4 J w T O FORM CREATES CONCRETE RECESS TO 2X4 (NOM.) RECEIVE GARAGE DOOR AND TO ALLOW FOR WATER SHED. KEEP STIFFENER BACK FROM SIDES ENOUGH TO ALLOW SPACE FOR FLAT MASONS TOOLS (THIS IS A RECOMENDATION FOR CONSTRUCTION OF THIS FORM. ANY MATERIAL OR CONSTRUCTION METHOD MAY BE USED PROVIDED END PRODUCT MEETS THE SHAPE AND DIMENSIONS OF THIS DRAWING.) GARAGE ENTRY FORM DETAIL �8x8x16 C.M.U. GARAGE DOOR GARAGE DOOR ROLLER _ CONNECTION ASSEMBLY :..' GARAGE FLOOR TRAVEL DIRECTION OF GARAGE DOOR MOUNTING BASE DETAIL SCALE: N.T.S. -TRACK MOUNTING BRACKET GARAGE DOOR TRACK SCALE: N.T.S. d e POURED CONCRETE BASE FOR BOTTOM OF MOUNTING B BLOCK WALL. RECESSED SPACE TO BE 2" ABOVE FINISHED FOR GARAGE DOOR AND WATER GARAGE FLOOR. SHED FORWARD THIS DRAWING. PARTIAL INTERIOR ELEVATION SCALE: N.T.S. 19 m 7 5/8" 8" 7 5/8" 8" 7 5/8" 8" SOLID AREAS ARE ❑ ❑ STEEL AND GROUT ❑ ❑ INTERIOR WALL ❑ ❑ ❑ CL DOOR OPENING DOOR OPENING EXTERIOR ❑ ❑ WALL ❑ ❑ ❑ 1ST COARSE 2ND COARSE 3RD COARSE MASON TO LAY BLOCK AS SHOWN ABOVE. EVERY COARSE MUST BE BONDED TO THE COARSE BELOW. EVERY THIRD (3RD) COARSE THE 1 V DOORJAMB WALL IS TO BE WOVEN INTO THE MAIN FRONT TO REAR WALL AS SHOWN. MASONRY LAYOUT rD SCALE: N.T.S. SL� In ai>(L•110". IN SOLID AREAS ARE STEEL AND GROUT FULL 8x8x16 BLOCK DOOR OPENING 5/8"DIA. x 8" J-BOLTS AT 6-3/4", 41-3/4", 71", AND 96-3/8" ABOVE GARAGE FLOOR. ALL J-BOLTS WILL BE IN FILLED CELLS (2,000 PSI MIN. CONCRETE). ANCHORS MAY BE COUNTERSUNK (BUT NOT REQUIRED) USS BOTTOM CHORD OR 2x4 TO PROVIDE A FLUSH MOUNTING SURFACE. HORIZONTAL JAMBS DO EBLOCKINGW/ 2-16d TOE NAILS NOT TRANSFER LOAD. EACH END ° d d WALL d ° a DOOR STOP w v ° d MOLDING J_?n ° 2x TOP PLATE '- GARAGE 2-16d NAILS @ 24" O.C. OR IDOOR EQUAL TO TRUSS BOTTOM CHORD OR BLOCKING 2 x 6 P.T. 2x STUD @ 24" O.C. MAX. PROVIDE P.A.F. NAILS OR 2x P T PLATE EQUAL @ 12" EO.C.. SEE TYPICAL WALL SECTION 12 PRE-ENGINEERED WOOD TRUSSES @ 24" O/C Z(T7y P) SEE ELEV. UPLIFT CONNECTOR (SEE SCHEDULE) DOUBLE 2"x4" S.P.F. TOP PLATE 7/8" STUCCO FINISH PER ASTM C. 926 APPLY 3 LAYERS W/ TOTAL THICKNESS 7/8" OVER METAL LATH. FIRST 2 LAYERS 3/8" THICK EACH. 3RD LAYER 1/8" THICK. i--CRICKET AS REQUIRED SIMPSON SP2 w/ (12)10d NAILS AT EACH STUD 1/2" EXTERIOR GRADE SHEATHING FASTENED TO TRUSSES WITH 8d COMMON WIRE NAILS @ 4" O/C BOUNDARIES 6" O/C EDGES & 8" BLOCKING O/C FIELD 2X4 PT STUDS @ 16" O.C. (2) 2X4 PT STUDS UNDER HIP CARRIER/GIRDER TRUSS SIMPSON HETA20 w/ (8)10dx1 1/2" NAILS AT EA. TRUSS VERTICAL WEB (24" O.C. MAX) w/ MIN. 4" EMBEDMENT IN KO BLOCK AT EA. STUD MAIN SPAN ROOF TRUSS MOISTURE BARRIER UPLIFT CONNECTOR 8"X8"X16" K.O. BLOCK W/ 1 #5 CONT. (SEE SCHEDULE) AND FILLED W/ GROUT 1 #5 VERT. IN CONC. FILLED CELL-- W/ STD. 900 HOOK IN K.O. BLOCK ALT. KNEEWALL ABOVE MASONRY WALL DETAIL SCALE: N.T.S. PIPE OR DUCT w/ PENETRATION THRU TOP PLATE w/ MORE THAN 50% OF TOP PLATE WIDTH INSTALL SIMPSON PSPN516Z w/ (12)16d NAILS TOP 2 ROWS 10d @ 3" O.C. (14 SPLICE -7 /_� NAILS TOTAL) EA. SIDE OF 48., SPLICE STAGGERED • M �-10d @ 8" O/C STAGGERED FROM BOT. -� "�/ ATTACH ALL J SEE A/S3 FOR SLATE TO CONCRETE DOOR TRACK EXTERIOR STUDS REINF. INFO. W/MOUNTING ANGLE W/ 4 16d TOENAILS TO P PLATE ° d NOTE: REFER TO GARAGE DOOR PRODUCT APPROVAL SHEETS NOTE: FOR DOOR INSTALLATION INFORMATION PER MANUFACTURER. PLATE LENGTHS MUST BE BOTTOM SPLIC AT LEAST 4'-0" LONG. TYPICAL OVER STUD TYPICAL INTERIOR NON - BEARING WOOD FRAME WALL TYPICAL GARAGE DOOR BUCK K TOP PLATE SPLICE DETAIL M SCALE: N.T.S. S4 SCALE: N.T.S. S4 SCALE: N.T.S. S4 F= 2240 LBS PSON SIMPSON SIMPSON C HEADER SUPPORT NO. OF JACKS & STUDS REQ. AT OPENINGS OPENING 2" x 4" WALL 2" x 6" WALL STRAPS JACKS STUDS JACKS STUDS SIZE EA END EA END EA END EA END SIMPSON 1' - 4' (1) (2) (1) (2) (1) LSTA30 4' - 9' (2) (3) (2) (2) (1) LSTA30 9' -16' (3) (4) (2) (4) (2) LSTA30 FLAT STRAPS PER CHART ABOVE TO BE BENT OVER TOP PLATE ** HOLD DOWN CONNECTIONS NOT REQUIRED @ BEARING WALLS NOTED WITHOUT UPLIFT SEE FLOOR PLAN NOTES FOR REQUIRED CONNECTION SFF �Nh' 2-ROWS 12d NAILS STAGGERED @ 12" O/C EACH FACE OR 3-ROWS 12d NAILS STAGGERED @ 12" O/C FOR 2"x10" OR 2x CRIPPLES @ GREATER HEADER 16" O.C. W/ (2)12d TOENAILS T/B o SIMPSON SP4 w/ (6) (2) 2x HEADER SEE PLAN 10d x 1 1 /2" AT EA STUD (USE SP6 FOR • INTERIOR HEADER: S4 2x6 WALL, USE SP8 (1) 2x SILL PLATE W/ (2) FOR 2x8 WALL) 12d TOENAILS BOX HEADER • EXTERIOR HEADERS: 10d NAILS @ 8" ONLY (1) 2x SILL PLATE W/ (2) 0/C TYP. 12d TOENAILS DOUBLE 2x • OPENING LARGER THAN 4 FT: CRIPPLE STUD (2) 2x SILL PLATE w/ SIMPSON TYPICAL (U.N.O.) LS30 w/ (6)10d x 1 1/2" EACH SIDE 2x STUDS TYP. OO SIMPSON HTT4 TYP. OHO �9 U.N.O. SEE N/S4 FN�NO, ** HOLD DOWN CONNECTIONS NOT REQUIRED @ P.T. BOT. PLATE BEARING WALLS NOTED WITHOUT UPLIFT WALL HEADER DETAIL Q SCALE: N.T.S. S4 5/8"x10" "J" BOLT @ 24" O.C. MAX. MIN. (2) PER BOTTOM PLATE SECTION SP4 0 TRANSOM FRAMING SEE SECTION AA/S1 AND BB/S1 FOR ADDITIONAL DETAILS _MM�Ma R . INTO TRANSOM TRANSOM FRAMING FRAMING 2X P.T. SEE SECTION AA/Sl PLATE AND BB/S1 FOR - ADDITIONAL DETAILS SIMPSON SP1 SIMPSON SIMPSC RECESS SP4 SP4 / LINTEL SIMPSON SP4 —I ° SIMPSON SP2 NAILED INTO TRANSOM FRAMING SIMPSON Sp1 SIMPSON RECESS / SIMPSON SP4 LINTEL / 2"x BUILT-UP COLUMN, SOLID MEMBER OR P.L. 1.8E Fb=2400 PSI (AS PER PLANS) ° o ° • HTT4 w/ (18)10d NAILS (3610# SPF) ° o • HTT5 w/ (26)10d NAILS (4670# SPF) ° ° • DTT2Z w/ (8)1/4" x 11/2"SDS (1835# SPF) ° e ° • HDU2-SDS2.5 w/ (6)1/4" x 21/2" SDS (2215# SPF) ° ° • HDU4-SDS2.5 w/ (10)1/4" x 21/2" SDS (3285# SPF) _ • HDU5-SDS2.5 w/ (14)1/4" x 21/2" SDS (4065# SPF) • HDU8-SDS2.5 w/ (20)1/4" x 21/2" SDS (5665# SPF) • HDU11-SDS2.5 w/ (30)1/4" x 21/2" SDS (6865# SPF) • 5/8" DIA. x 12" EPDXIED A.T.R. MIN. 8" EMBEDMENT wl WASHER & NUT C • FOR DTT2Z USE 1/2" DIA. x 12" EPDXIED A.T.R. MIN. 8" EMBEDMENT w/ WASHER & NUT • FOR HDU8 USE 7/8" DIA. x 12" EPDXIED A.T.R. MIN. 8" EMBEDMENT w/ WASHER & NUT • FOR HDU11 USE 1" DIA. x 12" EPDXIED A.T.R. MIN. 8" EMBEDMENT w/ WASHER & NUT HTT / HDU TENSION TIE rN SCALE: NTS S4 `10d NAILS @ 6" STAGGERED io t J-BOLTS @ 24" O.C. MAX -2X P.T. PLATE ROOF TRUSS ABOVE F 2X BLOCKING ° I I d 2X8 P.T. BOTTOM P TE 5/8"x10" "J" BOLT @ 24" O.C. MAX. C (MIN. (2) PER BOTTOM PLATE) SIMPSON C FFSP4 d / d 2X8 P.T. BOTTOM PLATE D 5/8"x10" "J" BOLTS @ 24" O.C. MAX. (MIN. (2) PER BOTTOM PLATE) -(2) 16d TOE NAILS EA. BLOCKING 2X8 WALL ABOVE ENTRY 1� K.O. BLOCK W/(1) #5 CONT. & FILLED 5/8"X10" J-BOLTS @ 2'-0" O.C. MASONRY WALL 10d NAILS @ 4 10d NAILS @ 6" O.C. STAGGERED A STAGGERED TRANSOM FRAMING o o BEYOND. PLYWOOD FASTENED TO TRUSSES WITH 8d COMMON WIRE NAILS @ 4" PLYWOOD O/C BOUNDARIES 6" O/C EDGES o E SHEATHING & 8" O/C FIELD S4 B • SIMPSON SP4 w/ (6) 10d x 1 12"zo (USE SP6 FOR 2x6 WALL, USE PLYWOOD SP8 FOR 2x8 WALL) 0 SHEATHING • SIMPSON SP2 w/ (12)10d NAILS MASONRY • SIMPSON SP1 w/ (10)10d NAILS WALL BELOW 5/8"X10" J-BOLTS @ 24" O.C. MAX. (MIN. (2) PER BOTTOM PLATE) ALTERNATE: 5/8" DIA. ATR EPDXIED MIN. 6" INTO BOND BEAM @ 24" O.C. �� FRAMING DETAILS ABOVE ENTRY / R \ SCALE: N.T.S. LO zo i z� z a 01) z Cz V) C9 4--J w m o •V — 0 120 E V7 � 0 m l.l..l ' ~ C f0 M O O N _ �"00 `° C> C. ¢ m c o A B D.'W .WT1 OC w W To the best of the EngirieeWWS knbw('Qdge,-i belief, the structural plans lnd„specificado ntain% within these drawings compIvi/.h' p ,Z } FIvp(!% , lh� Building Code - Residential 6th Edit=a1''A signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. O Z N O r� 4-0 CD :3 9.IlDi zM > (n M O ""j OLn a L- LL. a e-N Cr U o. -cr. Z § E J W J Z W n Za �48,0 W Z Z z 'zo Z.1� O J 0�EI 00 Eta H go L Z Ln P12$ 0< g N w o �E 5a 0 Q z uj3 $ J T-I g2 u- Lii Q Z N Cn z t U.1FH $ 4 m O N oo g = T-I a U0 � SCALE : AS NOTED DATE : 3/18/2018 TECH: FFLORES VERSION NO° 10 SHEET NO. S4 SIMPSON HGAMV wl (4)1/4"x1 1/2" SDS SCREWS TO BLOCKING & (d 1 /4'W 3/4" TITEN TO CMU SEE STRUCTURAL NOTES AND BACKNAIL W/ (2)16d NAILS BACKNAIL w/ (2)16d NAILS SIMPSON H10A w/ (18) SIMPSON SP4 W/ (6)10d x NAILING SCHEDULE FOR TOENAIL W/ (2) 16d NAILS SIMPSON H10A w/ (18) 2"x4" OUTLOOKER SEE STRUCTURAL NOTES AND 10d x 1 12" AT EA. 2x4a 1 Od x 1 12" AT EA. 1 12" AT EA STUD SEE STRUCTURAL NOTES (USE BACKNAIL w/(2) 16d NAILS SIMPSON H10A w/ (18) SHEATHING DETAIL OUTLOOKER OUTLOOKER 0P6 FOR 2 6 WALL USE " TOP CHORD @ 24" O.C. BLOCKING FOR FIRST FOUR NAILING SCHEDULE FOR OU I LOOKER SHEATHING DETAIL MNU @ FOR SHEATHING 24" O.C. DETAIL TOP CORD BLOCKING ROWS OF 45° ± 24 MAX. TOP CORD BLOCKING 45°± 2X4 CONT"L" BRACE TRUSSES @ SIMPSON H10A w/ (18) FOR FIRST FOUR FASTENED W/ (2)10d 3" FOR FIRST FOUR ROWS EDGES OF 2X4 CRO BRACE 10d x 1 12" @ EA. ROWS OF TRUSSES @ AT 24" 0/C. CMID HEIGHT OF TRUSSES @ EDGES SHEATHING APPROX. 8" FROM OUTLOOKER EDGES OF OF SHEATHING TYPICAL TYPICAL @ RIDGE FASTENED AT "L" BRACE TO EXTEND SHEATHING TYP. 2X4 KICKER 2x8 SYP#2 "L" BRACE TO 48" O.C. EACH JOINT W/ (3) 10d � �� @ g -0 0/C. EXTEND AT LEAST 90% OF MAX. & (2)10d TOE NAILS @ AT LEAST 90% OF WEB 2x4 CROSS BRACE WEB LENGTH & NOTCH AT EA. END @ 48" O.C. LENGTH (SEE TABLE) APPROX. 8" FROM BOTTOM CHORD (SEE TABLE) 2x6 P.T. GABLE TRUSS RIDGE FASTENED AT SIMPSON H2.5A w/ (10) 8d • SILL 1/2" CDX PLYWOOD OR EACH JOINT W/ (2) 10d FROM LEDGER TO ; 7/16" OSB SHEATHING & (2)10d TOE NAILS @ BLOCKING ATTACHED W/ 10d EA. END NAILS @ 6" O.C. EDGES GYPSUM WALL BOARD GABLE TRUSS AND 12" O.C. FIELD 2"x4" PANEL BLOCKING @ 48" O.C. FOR THE FIRST 10dX3" 3" O/C (4) ROWS OF TRUSSES FROM EA. END TYP. BOTTOM 1/2" CDX PLYWOOD OR 7/16" THROUGH CHORD CORD ATTACHED W/ (2)16d TOENAILS OSB SHEATHING ATTACHED 10d 6" O.C. "T" INTO 2"x6" P.T. PLATE 2"x4" LEDGER (MATCH BOTTOM CHORD w/ NAILS @ EDGES AND 12" O.C. FIELD 2x4 PANEL BLOCKING @ 2x4 ON TOP OF PANEL BLOCKING, WEEP SCREED SLOPE OF ADJACENT SCISSOR TRUSS) `• O.C. FOR THE FIRST (4) FASTEN WITH 1063" @ 4" O/C SPACED INSTALLED PER MANUF. 2"x6" P.T. SILL NOTCH "L" BRACE HERE ROWS OF TRUSSES FRO @ 48" O.C. MOISTURE BARRIER 5/8" x 10" "J" BOLT @ 48" O.C. WEEP SCREED EA. END TYP. TOP & BOTTOM ATTACHED w/ (2 5/8"x 10" "J" BOLT @ 32" O.C. MINIMUM 6" FROM SIMPSON HETA20 w/ (8)10dx1 1/2" NAILS AT 6'-0" INSTALLED PER MANUF. 16d TOENAILS PLATE SPLICES W/ 3/16"x2" 0 PLATE WASHER SIMPSON HETA20 w/ (8) O.C. MAX w/ MIN. 4" EMBEDMENT IN KO BLOCK - MOISTURE BARRIER 10dxl 1/2" NAILS AT EA. ALTERNATE SIMPSON MSTAM24 w/ (7)10d NAILS NOTE: IF EMBEDDED TRUSS VERTICAL WEB (24" & (4)1/4"x21/4" TITEN @ 4'4' O/C ALIGNED WITH STRAP MISSED VERTICAL SECTION O.C. MAX) w/ MIN. 4" 1 EMBEDMENT IN KO BLOCK GABLE WEB SECTION 2 WEB, USE MSTAM36 w/ (7) 1Od NAILS & (4) 1/4"x2 1/4" SCALE: N.T.S. S5 SCALE: N.T.S. S5 TITEN ON OUTSIDE SIMPSON H10A w/ (18) BACKNAIL W/ (2)16d NAILS x SP8 FOR 2x8 WALL) SEE STRUCTURAL NOTES 1 Od x 1 12 AT EA. OUTLOOKER AND NAILING SCHEDULE 2x4 OUTLOOKER 7 2x4 OUTLOOKER @ 24" FOR SHEATHIN DETAIL @ 24" O/C O.C. (OPTIONAL -SEE TOP CORD 4" MAX. ELEVATIONS) BLOCKING FOR FIRST FOUR ROWS DOUBLE TOP PLATE OF TRUSSES @ 2x4 CROSS BRACE APPROX. 8" 2"x4" CROSS BRACE 24" MAX. EDGES OF FROM RIDGE FASTENED AT APPROX. 8" FROM SHEATHING TYP. EACH JOINT W/ (2)10d & (2)10d RIDGE FASTENED AT "L" BRACE TO EXTEND TOE NAILS @ EA. END EACH JOINT W/ (2) ; AT LEAST 90% OF WEB 10d & (2)10d TOE LENGTH (SEE TABLE) 2x FRAME WALL (SEE WALL NAILS @ EA. END GABLE TRUSS SECTION FOR SIZE & SPACING) 2x4 PANEL BLOCKING 1/2" CDX PLYWOOD OR 1/2" CDX PLYWOOD OR 7/16" @ 48" O/C FOR THE (2)16d 7/16" OSB SHEATHING OSB SHEATHING ATTACHED FIRST (4) ROWS OF NAILS ATTACHED w/ 10d NAILS W/ 10d NAILS @ 6" O.C. EDGES TRUSSES FROM EA. @ 6" O.C. EDGES AND 12" AND 12" O.C. FIELD END TYP. TOP & O.C. FIELD (2)16d NAILS BOTTOM ATTACHED 48" 2x BLOCKING W/ (2)16d TOENAILS 2x4 "T" ON TOP OF PANEL BLOCKING, FASTEN WITH M 2x4 "T" ON TOP OF PANEL 10dx3" @ 4" 0/C BLOCKING, FASTEN WITH SIMPSON HGAIOKT w/ (4)1/4"x1 1/2" 1 Odx3" @ 4" O/C SDS SCREWS SDS SCREWS TO TRUSS & (4)1/4"x3" TO PLATES AT 36" O.C. SIMPSON SP2 w/ (12)1 Od 2x4 LEDGER (MATCH BOTTOM NAILS AT EACH STUD CHORD SLOPE OF ADJACENT DBL. TOP PLATE TRUSS) STUD WALL (SEE TYP. SEC.) SECTION 3 SECTION 4 SCALE: N.T.S. S5 SCALE: N.T.S. S5 -REFER TO DETAIL J 1 Od x 1 12" AT EA. 2x4 OUTLOOKER ON SHEET S5 FOR N N SEE STRUCTURAL OUTLOOKER @ 24" O/C X-BRACING, AND TOP " NOTES AND NAILING TOP CORD CHORD BLOCKING N SCHEDULE FOR BLOCKING FOR INFORMATION `° `° °° SHEATHING DETAIL FIRST FOUR ROWS OF TRUSSES @ 2"x4" CROSS BRACE 24" MAX. EDGES OF -WOOD TRUSSES �, APPROX. 8" FROM SHEATHING TYP. RIDGE FASTENED AT "L" BRACE TO EXTEND 2x4 RAT RUN BRACING ` EACH JOINT W/ (2) ; AT LEAST 90% OF WEB AT 24 O.C. ON TOP OF 1 Od & (2)10d TOE LENGTH (SEE TABLE) BOTT. CHORD FOR 4 NAILS @ EA. END GABLE TRUSS TRUSS SPANS ATTACHED W/ 2 -16d 2x4 PANEL BLOCKING CDX PLYWOOD OR 7/16" AT EA. TRUSS JOINT (2) 2" x 4" LAMINATIONS W/ (1) ROW (3) 2" x 4" LAMINATIONS W/ (1) ROW (3) 2" x 6" LAMINATIONS W/ (2) ROWS OF @ 48" O/C FOR THE FIRST (4) ROWS OF OS OSB SHEATHING ATTACHED (2)16d NAILS W/ 1 Od NAILS @ 6" O.C. 2x4 BLOCKING @ 24" OF STAGGERED 10d COMMON WIRE NAILS OF STAGGERED 30d COMMON WIRE NAILS STAGGERED 30d COMMON WIRE NAILS TRUSSES FROM EA. ; E ES AND 12" O.C. FIELD O/C w/ (2)16d (D = 0.148", L = 3") OR EQUAL (D = 0.207", L = 41/2") OR EQUAL „ (D = 0.207a L = 4, 1/2) OR EQUAL END TYP. TOP & JACK TRUSS TOENAILS @ EA. END NOTES: BOTTOM ATTACHED SEE PLAN FOR 11 ADJACENT NAILS ARE DRIVEN FROM OPPOSITE SIDES 4) FOR 4-PLY, PROVIDE 1/4" DIA. x 51/2" LAG SCREWS OR EQUAL w/ (2)16d TOENAILS CONNECTION MASONRY WALL OF THE COLUMN (SPACE AS SHOWN FOR 3-PLY) ARCHITECTURAL FINISH 2) ALL NAILS PENETRATE AT LEAST 3/4 OF THE THICKNESS 5) FOR 5-PLY, PROVIDE 1/4" DIA. x 7" LAG SCREWS OR EQUAL OF THE LAST LAMINATION (SPACE AS SHOWN FOR 3-PLY) 2x4'T" ON TOP OF PANEL BLOCKING, FASTEN WITH 2X4 BLOCKING W/ 3) EACH 30d COMMON NAIL MAY BE REPLACED W/ (2)16d 6) REFER TO NDS SECTION I D.3 FOR ADDITIONAL INFORMATION 10dx3" @ 4" 0/C (2)12d TOENAILS _. . EXT. WALL CONN. @ COMMON NAILS. (ONE INTO EACH OUTSIDE FACE OF NON - LOAD BEARING LOCATION B.U.C. SAME NUMBER OF ROWS SAME SPACING) ) SECTION g SEE TYP. WALL SECTION FOR SCALE: 3/4" = V-0" S5 TYPICAL NAILING SCHEDULES FOR BUILT-UP COLUMNS 8 ADDITIONAL INFORMATION. SCALE: N.T.S. S5 SCALE: N.T.S. S5 2"x4" OUTLOOKER @ 24" - O.C. W/ (2)10d PER JOINT IINIMUM 2x :ROSS BRACING 3EE PLAN FOR OCATIONS) 10dx3" O/C 2"x4' TOENAIL 6" O/C RUN W/ (2)16d TYPICAL (2)16d PER NAILS JOINT L- CONTINUOUS BOTTOM CORD BRACING 2"x4" MIN. SEE M/S5 CROSS BRACING DETAIL J SCALE: N.T.S. S5 ALTERNATE NON —DROP GABLE END DETAIL SCALE: N.T.S. 1 GABLE TRUSS 55 "L" BRACE W/ 10d @ 4" O.C. 12 (SEE SCHEDULE FOR SIZE AND LOCATION) 6.9 MAX. S5 S5 I ° e ,II • .. ..II I_ `II'.` a ° j- \, 4 e . II °` . 1� • I . ` I . ,. 11 ° °a it.-` ` 11.. 11 `CONT. BEARING GABLE END BRACING DETAIL MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION SCALE: N.T.S. 8d @ 6"O/C 2 x 4 BLOCKING w/ (2)1 Od WOOD TRUSSES TOE NAILS AT EACH END @ 124" O/C (TYP) 0 Z w BRACING w/ (3)10d x 3" AT • EACH CONN. @ 24" O/C SIMPSON HGAM10KTA w/ (4) MOISTURE BARRIER 1/4"x1 1/2" SDS SCREWS TO BLOCKING & (4)1/4"x2 3/4" BOND BEAM TITEN TO CMU nt--- MASONRY WALL 2x4 BLOCKING 2x4 "T" BLOCKING @ 48" O.C. 16d NAIL "L" BRACE ATTACHED W/ 10d NAILS @ 4" O.C. TYPICAL GABLE TRUSS WEB DOUBLE "L" BRACING DETAIL 5 SCALE: N.T.S. S5 2x4 "T" BLOCKING 2x4 BLOCKING @ 48" O.C. "L" BRACE ATTACHED 16d NAIL W/ 10d NAILS @ 4" O.C—pill TYPICAL GABLE TRUSS WEB J SINGLE "L" BRACING DETAIL/'_6 SCALE: N.T.S. DIAPHRAGM BLOCKING @ 48" O/C GABLE TRUSS TRUSS VERTICAL (2) 2"x8" "L" BRACE -� FASTENED WITH (3) 16d PER SIDE SCISSOR GABLE "T" BRACE AS PER HIB 91 SCALE: N.T.S. S5 20'-0" MAX 20'-0" MAX "X" BRACE SEE DET. J/S5 I CONTINUOUS BOTTOM' OTTO CHORD BRACING 2X4 MIN. I ��I ARCHITECTURAL FINISH NOTE: EXT. WALL CONN.(� NON —LOAD BEARING LOCATI01� (UNEVEN CLG.) SEE TYP. WALL SECTION FOR ADDITIONAL INFORMATION. SCALE: N.T.S. E S5 1) SEE TRUSS MANUFACTURER'S TRUSS ENGINEERING CUT SHEETS FOR ADDITIONAL PERMANENT BRACING THAT MY BE REQUIRED 2) "T" BRACING MAY BE USED IN PLACE OF PERMANENT BRACING PROVIDED IT EXTENDS OVER AT LEAST 90% OF THE WEB. REQUIRED MINIMUM PERMANENT TRUSS BRACING PLAN AS PER BCSI 1-13 SCISSOR TRUSS LTOP & BOTTOM CHORD GABLE END BRACING @ 4'-0" O.C. MAX. FOR FIRST (4) ROWS OF TRUSSES SCALE: N.T.S. _I OVERLAP TRUSS BRACING "L" BRACING REQUIREMENTS 2X4 BRACING @ 48" O.C. CONTINUOUS TO FIXED LOCATION ATTACHED W/ (2) 10d AT PRE -ENGINEERED --,,,,,—AT LEAST TWO TRUSS SPACES 6" OVERLAP STUD NO (1) 2"x4" (U.N.O.) 2"x6" (U.N.O.) EA. TRUSS NOTE: BRACING MAY BE WOOD TRUSSES( SPACING "L" BRACE "L" BRACE "L" BRACE PLACED ON EITHER TOP OR BOTTOM OF 24" 0'0" - T-0" T-0" - 6-0" 6'-0" & GREATER THE BOTTOM CORD) SCISSOR GABLE - (1) 2"x8" #2 S.P.F. @ EACH VERTICAL AND (2) 2"x8" FULL HEIGHT @ DIAPHRAGM BLOCKING `MINIMUM (2)16d PER JOINT L MINIMUM 2x4 TRUSS BRACING TRUSS BRACING OVERLAP DETAIL rm SCALE: N.T.S. S5 "L" BRACE W/ 10d @ 4" O/C (SEE SCHEDULE FOR SIZE AND LOCATION) a NOTE: 1) "L" BRACE MUST EXTEND AT LEAST 90% OF WEB LENGTH EXCEPT, SCISSOR GABLE WHICH REQUIRES BRACE TO EXTEND FULL HEIGHT OF GABLE. 2) "L" BRACE TO BE FASTENED TO GABLE STUD WITH 10dx3" NAILS @ 4" 0/C. 3) SEE 6/S5 FOR MORE INFO. SIMPSON HGA10KT w/ (4) 1/4"x1 1/2" SDS SCREWS TO TRUSS & (4) 1/4"x3" SDS SCREWS TO PLATES (TYP.) I- r-GABLE TRUSS \-STUDS @ 16" O.C. GABLE END BRACING DETAIL SCALE:3/4"=1'-0" MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION SIMPSON SP2 w/ (12) 10d NAILS AT EACH STUD END JACK 1 V-0" MAX. yGo LU a ✓,9 O� Y CORNERJACK Q Cr w Z m 0 U HIP FRAMING REFERENCE PLAN COSMETIC DROP CEILING FRAMING SCISSOR TRUSS W/ DROP CEILING BRACING DETAIL MEAN ROOF HEIGHT UP TO 30'-0" SCALE: NTS SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION WOOD FRAMED GABLE END BRACING DETAIL MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES SCALE: N.T.S. FOR WIND SPEED SPECIFICATION C9 zo — o z� z Q a 01) z 4--J w C6 p •U — Ow c e U_ B f —E — $ Cl) § 91 N O o0 _ U t U_ oD O0 ¢ 0) 9 :! Al I D D. C=&D Q P 9�1J` C11J olC��i Z 'w C7 W e a�iQ ALL 14 _ z ea � �a IA !� £ A §.\01 10 � oLL � W-° N To the best of the Engineer's `bwledge, inforrr,�y , anr� belief, the structural plans;and scmtiia7�`7,cbhtained��� within these drawings comply vyi�h the 2017 Flor' `0 Building Code- Residential 6th Editlod:,, qR , signature and seal is only for the strucEurdl engineering portions of the drawing pages bearing Engineer's signature and seal. 1f O O Z cV O N .2 I/-1 v% M CD M Q LF) -(0 LI) z QvCL �Ln C- 00 Q z E Z �.. J� W @Z Lu f� �¢ 0 Z U O 0adw � � H z o`2�gU-i go� 00 �o i M 00 � Z Lr) w 0 0 a LU fa z 0 ' � ' J a c N Q LL U � I� � ��za a3 z g- J Ln LLJ Z U N Q zg N z L go Im O 06 � = a rn ,-i a cn x SCALE : AS NOTED DATE : 3/18/2018 TECH: FFLORES VERSION NO' 10 SHEET NO. S5 (1) LAYER TYPE II (#30) UNDERLAYMENT FOR ROOF PITCH > 4:12 (2) LAYERS TYPE I OR TYPE II (#15 OR #30) UNDERLAYMENT FOR ROOF PITCH 4:12 OR LESS. 12 PRE ENGINEERED WOOD TRUSS @ 24" HURRICANE ANCHOR @EACH TRUSS O.C. MAX. SHINGLE ROOF SHINGLE ROOF 905 FOR UNDERLAYMENT REQUIREMENTS SEE R. INSULATION 15/32" CDX PLYWOOD OR 7/16" BAFFLE BAFFLE O.S.B. (SEE ROOF NAILING INSULATION P SCHEDULE ON SHT SN1) CHART ON FLOOR PLAN ALUMINUM DRIP EDGE ALUMINUM FASCIA 5/8" OR 1/2" HIGH STRENGTH CEILING 2x SUB FASCIA BOARD PER CODE W/ 13/8" DRYWALL NAILS OR DRYWALL SCREWS 7" O/C SEE SOFFIT SHEET CEILING & 8" O/C WALLS I ATTACHED WALL SHEATHING TO 1/2" GYP WB (2) TOP PLATE W/ 8d @ 4" O.C., 2 ROWS DOUBLE 2x S.P.F. TOP PLATE 1x2 NAILER ~ PLYWOOD SHEATHING 2X BLOCKING @ EA. WALL U) NAILED PER NAILING SCHEDULE SEE DETAIL C/S6 SHEATHING JOINT FOR MORE INFO 16" O.C. 2X S.P.F. STUDS o i W/ (4)16d TOENAILS TO TOP PLATE 7/8" CEMENTITIOUS FINISH PER ASTM C. 926 APPLY 3 LAYERS W/ TOTAL THICKNESS 7/8" OVER 2x BOT. PLATE W/ (2)10d @ 6" O.C. METAL LATH. FIRST 2 LAYERS 3/8" THICK EACH. 3RD 3/4" PLYWOOD DECKING GLUED AND NAILED W/ 10d � w LAYER 1/8" THICK. COMMON @ 6" O/C EDGES AND 12" O.C. FIELD = INSULATION PER 1/2" GYP. WB OR 3/8" PLYWOOD/ TYPE 2-M-W OSB CHART ON FLOOR PLAN (DRAFTSTOPPING) TO BE NAILED W/8d COMMON @ 6" O/C TO ONE SIDE OF THE FLOOR TRUSS FOR AN AREA 51000 g R SQ. FT. OF FLOOR AREA & SEALED PENATRATION AREA W/ FOAM. DRAFTSTOPPING SHALL DIVIDE THE CONCEALS S6 S6 SPACE INTO APPROX. EQUAL AREAS. FLOOR SYSTEM ETAL SEAT ER PLAN O OR FELT PAPER FOR MOISTURE BARRIER 1/7 HIGH STRENGTH OR 5/8" GYP WB (OR 5/8" GYP. TYPE " X" @ GARAGE ONLY) W/ 1 3/8" DRYWALL NAILS OR DRYWALL SCREWS 7" O/C CEILING & 8' O/C WALLS STD. 90 NOOK (SEE DETAIL) 1/2" GYP WB 8"x8"X16" CONC. KNOCKOUT INSTALLATION PER BILK. W/1#5 ROD CONT. FILLED CHART ON FLOOR PLAN SOLID W/GROUT NOTE: LAP SHEATHING TO BOTTOM OF BAND JOIST TYPICAL ARCHITECTURAL FINISH (1) #5 VERT. IN FILL CELLS (SEE FOUNDATION PLAN & NOTES) cM LL v 4"x4" INSPECTION PORT AT a EACH FILL CELL TYPICAL 1x WD FURRING @ 24" O.C. a AT GARAGE CONTRACTOR BASEBOARD N TO CUT BLOCK OR POUR MIN. 2500 PSI CONC. SLAB CURB DUE TO SLOPE MIN. PSI MAY VARY PER NOTE: EXTEND DECO FINISH MUNICIPALITY 4"to 6" BELOW GRADE FINISH GRADE A, 6x6 W1.4xW1.4 _ _ a : • c WWF OR FIBERMESH I STD.90'HOOK (3) # 5 REBAR ON 3" CHAIR 4" _ (SEE DETAIL) W/3" MIN. CLEARANCE TYP 2-STORY WALL SECTION ,1 SCALE:3/4"=V-0" S6 SIMPSON LSTA24 STRAP w/ (8)10d x 1 1/2" NAILS TO STUD F ._.. _ . ...- -- - • • •- - -- - - -- - 2nd FLOOR W BEAM/GIRDER 2ND FLOOR FRAME CONNECTION SEE J/S-6 FOR ADDITIONAL INFORMATION. SIMPSON LSTA24 STRAP w/ (8)10d x 1 1/2" NAILS TO STUD & (8)10d x 1 1/2" TO BAND JOIST AT EA. STUD 2nd FLOOR WALL--, • A 11 *SIMPSON LTP4 w/ (12) 8d x1 1/2" NAILS @ 24" O.C. 1st FLOOR WALL— SIMPSON LSTA24 STRAP w/ (8)10d x 1 1/2" NAILS TO STUD & (8)10d x 1 1/2" TO BAND — JOIST AT EA. STUD 2ND FLOOR FRAME CONNECTION @ WOOD 1ST FLR. UPLIFT CAP = 928 PLF SHEAR CAP = 355 PLF SEE J/S6 FOR ADDITIONAL INFORMATION. SCALE: N.T.S. SCALE: N.T.S. SPACER BLOCKS 'END SHEATHING TO IF BEAM OR GIRDER ,TE W/ O.C. IOR TRUSS/JOIST 2"x BOT. PLATE W/ (2)1od @ 6" O.C. NOTES: * USE LTP4 & EXTEND SHEATHING TO BOTTOM OF RIM BOARD/BAND JOIST FOR SHEAR WALL ONLY. CORNER TYPICAL'IT" AND CORNER DETAILS N SCALE: N.T.S. S6 2"x4" PANEL BLOCKING @ 48" O/C FOR THE FIRST 8'-0" OF END WALL FROM EA. END. (TYP.) TOP & BOTTOM CHORD ATTACHED W/ (2) 16d TOE NAILS DECKING — FLOOR TRUSSII SEE FRAMING PLAN l 2"x4" CROSS BRACE @ 48" O/C FOR THE 1ST 2'-0" OF END WALL W/ (2)10dx3" @ EA. END INTO 2"x4" BLOCKING E S6 2ND FLOOR FRAMING - SEE SECTION J/S6 ATTACHED WALL SHEATHING TO BOTTOM PLATE/CHORD W/ 8d @ 4" 0/C, 2 ROWS STAGGERED FLOOR TRUSS SEE FRAMING PLAN WEEP SCREED INSTALLED PER MANUF. SIMPSON HETA20 w/ (8)10dx1 1/2" NAILS @ 24" O.C. INTO TRUSS BLOCKING & MIN. 4" EMBEDMENT IN KO BLOCK 2ND FLOOR FRAME CONNECTION PARALLEL TO MASONRY WALL SCALE: 3/4"=V-0" SEE TYP. 2-STORY WALL SECTION FOR ADDITIONAL INFORMATION. 0 2x STUDS @ 1- 2"x BOT. PLATE (2)10d @ 6" 0.( PRE-ENGINEE FLOOR TRUSE, ATTACHED WALL SHEATHING CONTINUOUS TO BOTTOM RIBBON W/ 8d @ 4" O.C., 2 ROWS STAGGERED 2X4 RIBBONS, EACH W/ 4-16d NAILS INTO EA. FLOOR TRUSS WEEP SCREED INSTALLED PER. MANUF. SIMPSON HETA20 w/ (8)10dxl 1/2" NAILS AT EA. TRUSS w/ MIN. 4" EMBEDMENT IN KO BLOCK FLOOR CONNECTION g @ MASONRY 1ST FLR. SEE J/S6 SCALE: 3/4"=V-0" S6 FOR ADDITIONAL INFORMATION. PROVIDE CONTINUOUS BLOCKING FROM B.U.C. TO MASONRY BELOW (6)1/4" x 21/4" TITEN SCREWS TO MANSONRY I� WALL PER STRAP \ WOOD TO MASONRY CONNECTION W/ MSTAM36 SEE J/S6 FOR ADDITIONAL INFORMATION. B.U.C. (8)1 Od NAILS TO STUD PER STRAP SIMPSON MSTAM36 MASONRY WALL SCALE: N.T.S. RIBBONS DETAIL FLOOR TRUSS 0 SCALE:1 1/2"=V-0" "6,) NOTE: SEE TYPICAL WALL SECTION C/S3 FOR ADDITIONAL INFORMATION (1) ROW OF 2x BLOCKING @ MID HGT. FOR WALL HGT. 5 8'-6". (2) ROWS OF 2x BLOCKING @ 3rd PTS FOR WALL HGT. > 8'-6" SIMPSON SP1 w/ (10)10d NAILS AT EA. STUD 2 x STUDS @ 16" O.C. 2X P.T. PLATE :::X ..'. ... . . a :A a SEE SHEATHING SPECS ON FLOOR 1/2" GYP. W.B. MIN. @ GARAGE SIDE IF APPLICABLE 5/8"DIA. x 10" "J" BOLT W/ 8" EMBEDMENT @ 24" O.C. W/ 2"DIA.X 3/16" PLATE WASHER (MIN. SHEAR 3500#. MIN. TYPICAL TENSION 2600#.) 6 x 6 W1.4 x W1.4 WWF OR FIBERMESH T. — '°.• : . •• • d:.' (3) #5 CONT. ON Y 8" 11�8" 8" CHAIR W/ 3" MIN. CLEARANCE INTERIOR 2-STORY FRAME SECTION rs SEE TYP. 2-STORY WALL SECTION FOR SCALE: 3/4"=V-0" �_S6 ADDITIONAL SLAB INFORMATION. 15/32" OSB EXPOSUREI SHEATHING PROVIDE BLOCKING REQUIRED I SECTION X- NOT FULL HEIGHT SHI (2)- 2x TOP PLATE BEYOND I 15/32" OSB EXPOSUREI F SHEATHING w SOLID 2x a C BLOCKING @ ALL o C SHEATHING W EDGES (SEE OPENING SECTION X- a0 C x �W x I E F- 2x STUDS w BEYOND. y a SEE PLANZi U) I I I '--2x4 P.T. BASE 2x RIBBON OR -'VERTICAL A HORIZONTAL PLATE BEYOND BLOCKING SEE PLAN BETWEEN FLOOR WALL SHEATHING SYSTEM tA1Al I r-I I—t/A-rl^kl rIIA^r%ARM 4 FT. 4 FT. 0 O 2 2 5 FT. 4 FT. O O O 5 FT. 4 FT. 02 0 4 FT. 4 FT. O O 0 4 FT. ROOF NAILING ZONE DIAGRAM T�7 �Ow �N 2x CRIPPLES @ — 16" O.C. W/ (2)12d TOENAILS T/B 10d NAILS @ 8" O/C TYP. DOUBLE 2x CRIPPLE STUD TYPICAL (U.N.O.) ROOF NAILING SCHEDULE: NAILING ZONES (SHINGLE AND TILE) o Lu ZONE 1: 8d RING SHANK NAILS @ 6" O.C. ON EDGE AND 6" O.0 IN FIELD a u) ZONE 2: Bd RING SHANK NAILS @ 6" O.C. ON EDGE AND 6" O.0 IN FIELD z ZONE 3 8d RING SHANK NAILS @ 4" O.C. ON EDGE AND 4" O.0 IN FIELD C7 Z (NOTE: IF 5/8" PLYWOOD IS USED, CONTRACTOR MUST USE 10d RING LLO SHANK NAILS) = NOTE: co ROOF SHEATHING: (APA RATED EXPOSURE 1)1/2" PLYWOOD I r] 2 (TILE) OR 7/16" OSB MIN. (SHINGLES) SPAN RATED 24/16 W 25 0 Q Q 1' 8 6SHEATHING MAY BE INSTALLED VERTICALLY OR HORIZONTALLY, ATTACH F 0 co., S 'L PER NAILING SCHEDULE. PANEL EDGES WILL NEED TO BE ATTACHED TO K In IL2LL� STUD AND OR BLOCKING AT ALL EDGES, NW WO `✓ y U. A MINIMUM 1/8" SPACE IS RECOMMENDED BETWEEN PANELS AT EDGES AND END JOINTS TO ALLOW FOR EXPANSIONS FASTENERS SHALL NOT PENETRATE SURFACE MORE THAN 1/8" "34 ""S" = NAIL 3/8" PACING " S1/2" v2" S / SINGLE NAIL EDGE SPACING DOUBLE NAIL EDGE SPACING QA NAIL AT BASE 2 ROWS @ 4" O.C. W/8d COMMON NAIL © NAIL AT TOP PLATE TWO ROWS @ 4" O.C. W/8d COMMON NAIL © NAIL OPENING PERIMETER @ 3" O.C. W/8d COMMON NAIL OD NAIL INT. AT 3" O.C. W/8d COMMON NAIL Q STAGGER ALL VERT. JOINTS & NAIL @ 4" O.C. W/8d COMMON NAIL OF SHEATHING SPLICES @ HEADER - NAIL SHEATHING TO HEADER W/ 8d COMMON NAILS @ 4" O.C. © (2) 8d NAILS @ 3" O.C. TO EACH TRUSS END OR @ VERTICAL MEMBER IF GABLE END NOTE: • 8d NAILS FOR WALL SHEATHING MUST BE MIN .131" X 212" • DO NOT OVERDRIVE NAILS, FASTENERS SHALL NOT PENETRATE SURFACE MORE THAN 1/8". I AT ALL PANEL BLOCKING 4 LOCATIONS MIN 2 X 4 #2 SPF TURNED VERTICAL W/ 7/16" OSB FLITCH PLATE TOW/ (2) 12d TOENAILS EA. END. NAIL FLITCH PLATE TO VERTICAL W/ (4) 8d NAILS (2) 8d NAILS @ 3" O.C. C WALL SHEATHING INSTALL. S6 & NAILING SCHED. 2-ROWS 12d NAILS STAGGERED @ 12" O/C EACH FACE OR 3-ROWS 12d NAILS 4 STAGGERED @ 12" O/C FOR 2"x10" OR GREATER HEADER SEE FLOOR PLAN NOTES FOR REQUIRED CONNECTION 1 (2) 2x HEADER SEE PLAN S4 INTERIOR HEADER: BOX HEADER (1) 2x SILL PLATE W/ (2) ONLY 12d TOENAILS • EXTERIOR HEADERS: (1) 2x SILL PLATE W/ (2) 12d TOENAILS • OPENING LARGER THAN 4 FT: (1) 2x SILL PLATE w/ SIMPSON LS30 w/ (6)10d x 1 1/2" EACH SIDE Op ly 0 NO SEE PLAN FOR REQUIRED CONNECTIONS LOAD BEARING/EXTERIOR FRAME WALL HEADER DETAIL 2x STUDS TYP. P.T. BOT. PLATE FLOOR TRUSS / (2) ROWS OF 2x BLOCKING AT THIRD POINTS 5/8"DIA. x 10" "J" BOLT W/ 8" EMBEDMENT @ 24" O.C. W/ 2"DIA. x 3/16" PLATE WASHER (MIN. SHEAR 3500#. MIN. TYPICAL TENSION 2600#.) 2500 PSI CONCRETE MIN. SLAB W/ 6x6 W 1.4XW 1.4 `r WWF OR FIBERMESH C •:.d ° .. E a • : 04 A A.. 1 I I -I 11=I I I I I .•_ �I I II I II I II I II I II I ; .. •. . M S6 SECTION X-X HEADER SUPPORT NO. OF JACKS & STUDS REQ. AT OPENINGS OPENING 2" x 4" WALL 2" x 6" WALL STRAPS JACKS STUDS JACKS STUDS SIMPSON SIZE EA END EA END EA END EA END 1'4 1 2 1) 2 (1) LSTA30 4'4 (2) 3 (2) (2) (1) LSTA30 9'-16' (3) 3 (2) (3) 1 (2) LSTA30 PLYWOOD SHEATHING NAILED PER NAILING SCHEDULE SEE DETAIL C/S6 FOR MORE INFO 2X STUDS @ 16" 0/C 7/8" STUCCO FINISH PER ASTM C. 926 APPLY 3 LAYERS W/ TOTAL THICKNESS 7/8" OVER METAL LATH. FIRST 2 LAYERS 3/8" THICK EACH. 3RD LAYER 1/8" THICK. SIMPSON SP1 w/ (10)10d NAILS AT EA. STUD 2X P.T. PLATE WEEP SCREED INSTALLED PER. MANUF. FINISH GRADE 00 T (3) # 5 REBAR ON 3" CHAIR —�� 4" 1 V-8" W/3" MIN. CLEARANCE ALTERNATE FOOTING ry @ WOOD 1ST FLR. SEE J/S6 FOR SCALE: 3/4"=1'-0" ADDITIONAL INFORMATION. S6 Z co —o (D Z Z CD a Z W nV) 0 W cn 4—J w 0 V) E: N ~ lL o n m M 004 .2 CD _ ' Cun -= ! D Q rn �io B De "_c� ig U) LL CP ..■ : '4 W kineer To the best off Eh s•iinow , infprMation, an� belief, the structural plarA and socifica"As co(� ed �t within these dra�Lings comly.with the �TIpN a \� Building Code - ResidM ial 6tME#fitfggp ii%er' signature and seal is on%/fogfhe structural gng portions of the drawing pages'life0ylPgta$ s signature and seal. 1f O ON Z oil. I/ -I LO t.0 0 M QU#)'0Ln d .L d" N U_ CL ^ z fa- oc v a CO <( z � Z � Uj JoP t0 z za Ia- W �CQ' OU $z0: z �jw 0128,8 0�y0� 8� W aW �z 0 O U 7 z a W �g _ _ W oLL a. Q u, 95 cc g of N LjL z of �o Z W ^ o Lr) di Q LLI Zg z N k N ZLU O SCALE : AS NOTED DATE : 3/18/2018 TECH: FFLORES VERSION No. 10 SHEET NO. S6 FLAT STRAP NAILED TO RISER AND THEN WRAPPED AROUND STUD PLAN VIEW SCALE: " = 1'-0" E: THESE DETAILS ARE NOT PLAN SPECIFIC. THEY ARE PROVIDED TO YOU AS A STANDARD TO CONSTRUCT STAIRS. REFER TO PLAN DETAILS FOR RISE AND RUN INFORMATION. 2x4 SPF NOSING GLUED AND NAILED MATCH NOSING ON OTHER TREADS 3/4" RISER CUT TO FIT 2x4 SYP BLOCKING MAINTAIN BETWEEN 1/4" FOR STRAP (SIMPSON AND 1/2" GAP TOP AND MTS12 w/ (14) 10d x 1 BOTTOM, GLUED AND 1/2" NAILS) NAILED TO STRINGER 2x12 TREAD GLUED AND NAILED 2x4 PT NOTCHED INTO STRINGER AND TAPCO2x8 SYP DRYWALL STOP MUST INTO FLOOR WITH GLUNED NOT TOUCH STRINGERS STRINGER CONTACT 2x4 BLOCK IN KNEEWALL FOR 2x12 NAILING POINTS 1x4 GLUED AND NAILED TO STRINGER E FOR DRYWALL SPACING H SECTION VIEW SCALE: 4" = 1'-0" STRINGER MUST MAKE F1 CONTACT WITH LANDING 2x4 CUT ON BEVEL DOES NOT BEAR IN WALL GLUED TO 2x8 F STRINGER MUST MAKE FULL CONTACT WITH LANDING 2x4 CUT ON BEVEL DOES NOT BEAR IN •-LI IL WALL SECTIO FILLER STRIPS ADDED GLUED & SCREWED TO PLYWOOD DECKING '1' 12 2x SYP CUT TO FIT BEARS IN WALL --2x12 SYP BEARS IN WALL '--2x6 SYP B-� 2x12 SYP SCAB 2x4 GLUED AND NAILED (EACH SIDE) TO BOTTOM EDGE OF 2x12 ALIGN THIS STUD WITH 3/4" RISER CUT TO FIT STRINGER STRINGER FACE OF 2ND RISER MAINTAIN BETWEEN" AND J" GAP TOP AND BOTTOM, GLUED AND NAILED TO STRINGER 2x4 BEHIND RISER BLOCKING FOR 1x4 GLUED AND NAILED TO STRINGER STRAP GLUED TO 2x4 DRAFT RISER AND TREAD STOP /X/ FA 2x8 SYP DRYWALL STOP MUST NOT TOUCH STRINGERS '- 2x4 SYP BLOCKING ` /2x4 PT NOTCHED INTO STRINGER FOR STRAP AND NAILED TO FLOOR WITH GLUE (SIMPSON MTS12 w/ AT STRINGER CONTACT POINTS \ (14) 10d x 1 1/2" NAILS) ECTION VIEW "A" SECTION VIEW "B" SCALE: 1" = 1'-0" SCALE: 1" = V-0" ALIGN THIS STUD WITH FACE OF 2nd RISER Ga -2x4 BLOCKING FOR 2x12 2x4 PT UNDER 2x12 C ROVIDE MOISTURE PROTECTION LATTACH ALL COMPONENTS STAIR TO CONC. W/4"X TAPCONS @ MAX. 32" O.C.ATTACH ALL COMPONENTS 1x4 GLUED AND OF STAIR TO CONC. W/j" X NAILED TO STRINGER 2 4" TAPCONS @ MAX. 32" O.C. / SECTION VIEW "C" SCALE: 1" = V-0" 1x4 GLUED AND NAILED TO STRINGER x4 DRAFT 2P STOP 2x8 SYP DRYWALL STOP 2x SYP CUT TO FIT MUST NOT TOUCH STRINGERS BEARS IN WALL 2x12 SYP BEARS E IN WALL 2x4 BLOCKING FOR 2x12 2x4 PT UNDER 2x12 — 2x6 SYP 2x4 SYP BLOCKING FOR STRAP (SIMPSON MTS12 w/ /2x4 PT NOTCHED INTO STRINGER (14) 10d x 1 1/2" NAILS) AND NAILED TO FLOOR WITH GLUE AT STRINGER CONTACT POINTS \ N VIEW "D" SCALE: 1" = V-0" PLYWOOD 2x SYP CUT TO FIT BEARS IN WALL ---2x12 SYP BEARS IN WALL BULLNOSE DETAIL SCALE: 1" = V-0" 2x4 GLUED AND NAILED SECTION D-D -3/4 PLYWOOD ON DECK --2x8 SYP GLUED AND NAILED TO FRAMING 2x4 DRAFT 2x12 STOP TREAD GLUED AND 2x4 PT NOTCHED INTO I STRINGER AND TAPCONED INTO FLOOR WITH GLUE -AT - STRINGER CONTACT POINTS SCALE: 1" = V-0" SECTION VIEW "E" L2x8 SYP DRYWALL STOP MUST NOT TOUCH STRINGERS GLUED AND NAILED TO STRINGER FOR DRYWALL SPACING H E SECTION VIEW SCALE: i" = 1'-0" SCALE: 1" = V-0" -3/4 PLYWC ON DECK `-2x8 SYP AND NAI FRAMIN( 2x4 DRAFT STOP 2x4 BLOCKI C- I NOTE: 2x8 DRYWALL STOP NOT SHOWN TOP OF �- STRINGER CONN. TO BOTTi OF NEWEL POST PER CONTRACT, :L POST LET INTO ILOCK I DE KING I - MF-1 2X8 BLOCKING FOR NEWEL POST TO ANCHOR TO. FLOOR GIRDER PROVIDE SOLID BLOCKING (GLUED AND NAILED) 2X4 CUT ON OR 1 x 16" VL BELOW ALL NEWEL POST BEVEL GLUED FROM JOIST TO JOIST. USE AND NAILED TO 2 X 12 BLOCKS, GLUED AND FLOOR LVL NAILED TO JOIST. TRUSSES NEWEL POST SECTION VIEW "G" BLOCKING SCALE: 1" = T-0" F SECTION VIEW SCALE: 4" = 1'-0" SCALE: 1" = V-0" STAIR CONSTRUCTION DETAILS (IF 11 X1 7 REDUCE SCALE .5) SCALE: AS NOTED JOINT -TO )ISTS) NAILED AND )TOP PLATE NTO RIM BAND, JD NAILED TO WALL BELOW JOINT -TO )ISTS) H 2X STRI I 2X B OCKING PSON MTS 2 w/ 10d x 1 1/2" NAILS V2XBLOC D OR 3 RIS R VARIES ECTION VIEW "H" SCALE: 1" = V-0" ` 0 0 - Z M — o co Z Z Q a V) (D w �U — O� ISO � o �� f- U —8 ) rn M M 000 _ U� " w Nno Q cmA Qo B D. m� N z f Z4�r�✓ �r+�' �``� - rpm•'•... C w�P,r 2 ,;' oo l9a -0 To the best of CAS of meer kno d , infprmation, an� we e belief, the strueRutaJ plai,, and'sbeeifiptiCds co(�ViWred within these drawiYrgs corny-�aI>•,h the Oj��ffIpFiFJa Building Code - Resld'antial th"EFlid r�,. gineer' signature and seal is only for the structurall, e,t�. ing portions of the drawing pages'b,4#(4pK,4 jjItil�r's signature and seal. O Z C4 0 W r, a I> U-) M CD Q U-) M Ln °' n uNi H � Ln - CL .-. oC U aM-a < 00 E Z g W J � d- �z z d �a wQ�o: vzOp 00W Z w W gZI !z T v j w J W & 8 � 1 00 ® ONO � z z .� Q X Lr) w c z m fu z LU Ou r4 Q Q��o Zo W rl L n f W J r-1 LLJ Q LLJ � z a z o U Wa~ N Z � z m g q SCALE : AS NOTED DATE: 3/18/2018 TECH: FFLORES VERSION NO' 10 SHEET NO. ST 1X4 1/2" DRYWALL 1/2" DRYWALL DOOR JAMB REFER DOOR JAMB (REFER 1 X 4 ( 1 X 4 1/2" DRYWALL UNACCEPTABLE INSTALLTION , DOOR JAMB (REFER TO SHT. SDW2-K1 P.T. TO SHT. SDW2-K1 TO SHT. SDW2-K1 FOR CONN. DETAILS PROPER INSTALLATION MAX, 8 DO NOT DO THIS 2"x BOT. PLATE W/ (2)10d @ 6" O.C. FOR CONN. DETAILS FOR CONN. DETAILS 1 X 4 1 X 4 ` (TYR) ' #5 REPAR 3/4" PLYWOOD DECKING GLUED ATTACHED WALL SHEATHING TO 1 X 4 3-1/4" LONG X 3116"0 FURRING 3/16"� X 3" LONG FURRING 3116"0 X 3-1/2" LONG FURRING #5 REBAR AND NAILED W/ 8d COMMON @ 6 O.C. EDGES AND 12" Q.C. 2X BOTTOM PLATE W/ 8d @ 4" O.C., 2 ROWS STAGGERED TAPCON. INTO TAPCONS TAPCONS STAGGERED STAGGERED @ 16° 2X8 m'P.) ` FIELD BLOCK@ SPACING " 1 DETAIL 1X8 P.T. STAGGERED @ 16" O.C. O.C. 2-ROWS INTO 2-ROWS INTO 1X8 PER MANUFACTURE MASONRY THROUGH 1-1 /2" DETAIL MASONRY THROUGH 1� 3 DETAIL `STD. 90° HOOK (TYP.) STD. 90" ` 2x BAND JOIST W/ FACE NAIL 10d @ TOP & BTTM CHORD, AND (8) 1x4 P.T. & 1x8 P.T. 1x8 P.T. & 2x8 P.T. FILL SOLID BOTH CELLS HOOK (TYP.) FACE NAILS 10d @ TRUSS VERT. WEB 3/16" x 3 -1/2" TAPCON @ 16" 1X4 P.T. EILJI� METAL SEAT PLATE O.C. & 4" FROM 3/16" x 3 -1/2" DOOR JAMB (REFER 1 X 4 1/2" DRYWALL NOTE: DOOR JAMB REFER EACH END W! MIN ( DOOR JAMB (REFER TAPCON TO SHT. SDW2-K1 LAP SHEATHING TO TO SHT. SDW2-K1 2" EDGE DIST. TO SHT. SDW2-K1 CONN. DETAIL BOTTOM OF BAND JOIST TYPICAL FOR CONN. DETAILS IFOR FOR CONN. DETAILS 10d @ 12" O 1 X 4 FURRING 2X8 P.T. WITH 3/1 +2a NOTC @ FIRST COURSE SIMPSON HGAM10KTA @ 12" O.C. LONG TAPCONS 2X8 P.T. ' w/ (4) 1/4x1 1/2" SDS SCREWS 2x P.T. AS REQ'D " STAGGERED @ 16 O.C. ' EURSES ` INTO BAND JOIST & (4)1/4"x2 3/4" 2x DETAIL 2 1/4" DETAIL 2-ROWS INTO MASONRY 3-1/4" DETAIL ±5^ FIRST 2 COURSES TITEN INTO K.O. BLOCK BUILDOUT OVER SIZE DOOR -WINDOW ROUGH OPENINGS CC FILLED CELL PER SCALE: N.T.S. FOUNDATION PLAN FILLED CELL INSTALLATION H RETROFIT FOR MISSING EMBEDDED STRAP SS SCALE: N.T.S. SS SEE TYP. 2-STORY WALL SECTION FOR ADDL. INFO SCALE: N.T.S. 2x8 P.T. BUCK -CONNECT TO BLOCK SECTION UPLIFT CAPACITY = 805 # FOR 1 STRAP W/ 1/4" x 31/4" TAPCON (1 1/4"MIN. A -A =1610 # FOR 2 STRAPS FILL tst4 COURSES t4GROUT EMBEDMENT INTO BLK.) 1/4" MAX Z'-O" 8" .e SOLID 1 1 X 4 FURRING SOLID BLKG. AT TOP BTWN. 1/4" x 31/4" TAPCONS 1 PLY PRE-ENGINEERED TRUSS BLOCK HEADER ARCH BLKG. &BUCK SIMPSON HM9KT w/ (4)1/4"xi 1/2" SDS ° 1/2" DRYWALL * SCREWS & (5)1/4" x 21/4" TITEN (IF TRUSS IS 2 PLY INSTALL SIMPSON LGT2 w/ (16)16d 8d NAILS AT 8" O.C. AT BUCK SINKERS AND (7) 1/4"x2 1/4" TITEN = 2150 #) 2 x 8 45A DIAGONAL (4)10d NAILS INTO LEAVE A CUT OUT IN O.S.B. ON THE BRACE(S) 2 x 8 BRACE/ BLKG. INSIDE TO ALLOW FOR INSULATION 7/16" OSB 70 BE INSTALLED BOND BEAM OR CAST IN PLACE BEAM FOR OVERHANGS BETWEEN OVER 1 BUILT UP PLWD. BUCK ARCH PANEL CUT HOLE IN O.S.B. FOR CONTACT ENGINEER OF RECORD FOR OR POLY -CELL IN THIS AREA SCRIBE (NOTCH) 2 x 8 45 DIAGONAL BRACE AT EA. FURTHER INSTRUCTIONS. °. . FACE OF ARCH W/ (3)10d NAILS.� BACKSIDE TO FIT ARCH (4)10d NAILS INTO 2 x 8 AT EA. END RETROFIT TRUSS DETAIL OVERHAN CONNECT W/ 8d NAILS BRACE/ BLKG. •' °' N.T.S. INSTALL WDW. SCREW ANCHOR---' 2 x 4 SOLID BLKG. (FULL WIDTH OF WALL) BTWN. OSB PROVIDE TAPCON WITHIN INTO ARCH BLKG. PER ARCH FACES W (4)10d NAILS THRU OSB INTO 2 x 8 RETROFIT WALL OVERHANG DETAIL (NTS) 4" MIN. OF BRACE INSTALLATION DETAILS A 2 X 4 #2 SYP SCAB TO SIDE OF -A PROVIDE TAPCON PER WDW. INSTALLATION DETAILS OR THRU TRUSS AS SHOWN FOR O.H. UP TO 2'-6" FOR OVERHANGS BETWEEN 3/4" TO 1 1/2" 1-1/2" THK. OR MORE BUCK WITHIN 6" MIN. OF START OF ARCH 2X6 SYP #2 CONT. (MATCH TRUSS DEPTH * DOUBLE 2x4 SCAB FOR 2'-6" TO 4'-0" O.H. START OF ARC IF TRUSSES USED) W/ (3) #6 X 4Y2" WOOD NOTE: FOR OVERHANGS LESS THAN 314" - NO REPAIR READ. 4' MAX. RAD. SCREWS @ 16" O.C. MAX. OR IF MASONRY k0� (2)10d NAILS @ 8" O.C. FRygN ARCH DETAIL i WALL USE (3)1/4" X 31/2" TAPCONS AT 16" TO TRUSS TOP CHORD SCALE: N.T.S. SS O.C. 12 + �'T/y PLYWOOD SHEATHING 1—O�� 5�—Ole JACK TRUSS PROVIDED BY SEE + + TRUSS COMPANY OR PLAN 2x6 #2 SYP @ 24" O.C. + + + + INISH FLO 2 x 8 BUCK - CONNECT TO BLOCK SECTION + + BLOCKING AS ° WITH 1/4" x 31/4" TAPCON (1 1/4" MIN. B-B ROOF SHEATHING ATTACHED + REQUIRED > ° > EMBEDMENT INTO ) PER NAILING SCHEDULE ALL TO SUPPORT ° '. 14" MAX 2 -0n 8 TRUSS + SOFFIT + ° • • � s ' ' '' > �' #5 BAR �. BLOCK HEADER SOLID BLKG. AT TOP BTWN. ARCH () SIMPSON 5 12d NAILS + • 1'On ° D' ° e ° CENTERED W/ � 1 X 4 FURRING BLKG. & BUCK 2X6 TO 2X4 H2.5A w/ (10) 2X4 SYP ► , . o ° IN TOP 0 Sd NAILS EACH TRUSS > KNOCKOUT / Z14 8d NAILS @ 8" O.C. AT BUCK —� CHAIR BLOCK ° PROVIDE 2 x 8 DIAG. BRACE B 2 x 8 VERT. W/ (2)10d NAILS AT EA. END PROVIDE (2) MIN. PROVIDE 2x CONT. W/ (3) .� CONNECTOR - 01 MONO FOOTING _ .A •e.. .,° TAPCON AT EA. SIDE SIZE AND REINF. PER PLAN VERT. BRACES WHEN HGT. OF 12d NAILS SEE LINTEL -I BRACE EXCEEDS 24" BUCK- (1) WITHIN 4"DETAILS JACK TRUSS PROVIDED BY SCHED. AND SECTION DETAI LEAVE A CUT OUT IN O.S.B. ON T MIN. OF START OF TRUSS COMPANY OR 2x4 -I s 2 x 8 VERT. BRACES () INSIDE TO ALLOW FOR INSULATION ARCH #2 SYP @ 24" O.C. tENTER SO IT CLEAN FILL .► °. ! 6 z TO BE INSTALLED DIRT BUILT UP PLWD. BUCK- 4'-0' MAX SEE PLAN PRECAST LINTEL °. ° STANDARD o 9 SCRIBE (NOTCH) BACKSIDE 7/16" OSB ARCH PANEL 2X4 SYP #2 CONT. (MATCH TRUSS DEPTH SEE ELEVATION > 90' HOOK #5 BAR IN TO FIT ARCH CONNECT W/ START OF ARC IF TRUSSES USED W/ 2 #6 X 4tY." WOOD ) () FOR OVER HANG FILLED CELL, -. �. • � - � , 8d NAILSqN"2 x 4 SOLID BLKG. (FULL WIDTH OF WALLS) 4' MAX. RAD. SCREWS @ 16" O.C. MAX. OR IF MASONRY (MAX. 4 -0) ' T , �j . �� , BTWN. OSB ARCH FACES W/ (4)10d NAILS EQUAL EQUAL WALL USE (2) 1/4" X 31/2" TAPCONS AT 16" '` INSTALL WDW, SCREW THRU OSB INTO 2 x 8 O.C.sk �'� •� ,� ' 'r e� ' , s , •� ,� ANCHOR INTO ARCH BLKG, PER INSTALLATION DETAILS ARCH DETAIL K e-g SECTION @ENTRY L SECTION @ROOF EXTENSION M STEMWALL FOOTING SIZE AND REINF. PERLAN AND STEMWALL SCALE: N.T.S. MONO TO STEMWALL FOOTING SS SCALE: 3/4" =1'-0" SS SCALE: 3/4" =1'-0" SS SECTION DETAILS SCALE: 3!4" =1'-0" GLASS BLOCK INSTALLATION NOTES NOTE: IF RETROFIT FILLED CELL CONDITIONS EXCEED (3) PER PROJECT, A) COVER SILL AREA WITH A HEAVY COAT OF ASPHALT EMULSION. ALLOW EMULSION TO DRY AT LEAST 2 HOURS BEFORE PLACING MORTAR. CONTACT ENGINEER OF RECORD FOR ADDITIONAL INSTRUCTION. B) ADHERE EXPANSION STRIPS TO JAMBS AND HEAD. MAKE CERTAIN EXPANSION STRIP EXTENDS TO SILL. EXISTING BOND BEAM. C) SET A FULL MORTAR BED JOINT, APPLIED TO SILL. MASONRY WALL. SEE PLAN FOR D) SET LOWER COURSE OF BLOCK. MAINTAIN A UNIFORM JOINT WIDTH OF 3/8" PLUS OR MINUS REINFORCING. PROVIDE LOWER HOOKED DOWEL DRILL 3/4"x5" MIN. HOLE SET BAR IN 1/8". ALL MORTAR JOINTS MUST BE FULL AND NOT FURROWED. ALL MORTAR SHALL BE SEE SHEET D2 AND EPDXY CAP TO PREVENT LEAKAGE TYPE "S" OR "N". STEEL TOOLS MUST NOT BE USED TO TAP BLOCKS INTO POSITION. (PLACE EXPANSION STRIP FLOOR PLAN FOR A RUBBER CRUTCH TIP ON END OF TROWEL TO TAP BLOCK INTO POSITION.) DO NOT 20 ga. PANEL MORE INFO TOP SPACE BETWEEN EXISTING GROUT & NEW GROUT REALIGN, TAP, OR OTHERWISE MOVE BLOCK AFTER INITIAL PLACEMENT. FOR SOLID GLASS BLOCK IT MAY BE NECESSARY TO USE WEDGES IN THE MORTAR JOINTS OF THE LOWER ANCHOR W.W.M. AT PERIMETER SIMPSON SIMPSON HTT4 w/ (18)10d x 1 MUST BE PACKED WITH NON -SHRINK GROUT (USUALLY ± 2") COURSES TO PREVENT THE MORTAR FROM BEING "SQUEEZED" OUT. 1/4" EXPANSION BOLT (2 WHERE THIS CONDITION 1/2"NAILS TO STUDS & (1) - E) INSTALL PANEL REINFORCING IN EVERY OTHER MORTAR BED HORIZONTALLY AND IN JOINTS PER ANCHOR 9 ga. PANEL ) (1) #5 BARS CONT. OCCURS TOP WITH MIN. 3" 5/8" DIA. ALL THREAD ROD "SET" >- #5x6' EMBEDDED INTO EXISTING BOND BEAM cr Z IMMEDIATELY ABOVE AND BELOW ALL OPENINGS WITHIN PANELS. THE SAME SPACING ( REINFORCING EPDXIED w! SIMPSON a � 0 SHALL APPLY TO PANEL ANCHORS WHEN USED AT JAMBS AND HEADS IN LIEU OF CHANNEL (EVERY OTHER COVER 6'-0" F F EPDXY MIN. 6" EMBEDMENT & ` < FILL CELL FULL HEIGHT W/ OR CHASE SURROUNDS.) RUN REINFORCING CONTINUOUSLY FROM END TO END OF PANELS. COURSE) EXPANSION STRIP 3" MIN. EDGE DISTANCE LAP REINFORCING NOT LESS THAN 6 INCHES WHENEVER IT IS NECESSARY TO USE MORE °. o NON SHRINK GROUT. THAN ONE LENGTH. DO NOT BRIDGE EXPANSION JOINTS WITH REINFORCING. INSTALL n n LU A REINFORCING AS FOLLOWS: — v¢ U 1 * PLACE LOWER HALF OF MORTAR IN BED JOINT. DO NOT FURROW. SEALANT o e r P a g * PRESS PANEL REINFORCING INTO PLACE. _ - v #5x6, EMBEDDED INTO z * COVER PANEL REINFORCING WITH UPPER HALF OF MORTAR BED AND TROWEL 6 MIN. LAP SPLICE W/ REINFORCING PANEL > ° p EXISTING FOOTING 2 #5x6' IN CONC. a ( ) N FURROW. SMOOTH. DO 0 co N FILLED CELL ° IIII DRILL 3/4"x5"MIN. HOLE F PLACE FULL MORTAR B F R JOINTS NOT REQUIRING PANEL REINFORCING - DO NOT LAC U BED 0 QU �¢ GRADE o, ' o ` . SET BAR IN EPDXY FURROW. MAINTAIN UNIFORM JOINT WIDTH. 6 IN. LAP p g ° G) SET SUCCEEDING COURSE OF BLOCKS. SPACE AT HEAD OF PANEL AND JAMBS MUST SPLICE REMAIN FREE OF MORTAR. NOTE: z \ ` H) STRIKE JOINTS SMOOTH WHILE MORTAR IS STILL PLASTIC AND BEFORE FINAL SET, AT THIS SEE GLASS BLOCK INSTALLATION NOTES. r TIME RAKE OUT ALL SPACES REQUIRING SEALANT TO A DEPTH EQUAL TO THE WIDTH OF THE SEALANT ° ° � a 4" SAW CUT SPACES. REMOVE SURPLUS MORTAR FROM FACES OF GLASS BLOCKS AND WIPE DRY. GLASS BLOCK DETAIL \ ' (2) #5 RE BAR, MIN. 3" TOOL JOINTS SMOOTH AND CONCAVE, BEFORE MORTAR TAKES FINAL SET. (REMOVE WEDGES FROM LOWER COURSES OF SOLID BLOCKS AND POINT THE VOIDS WITH MORTAR.) GLASS BLOCK SHALL BE INSTALLED PER THE FLORIDA BUILDING CODE RESIDENTIAL SECTION R160 16" MIN. of COVER EA. WAY A SECTION 1) AFTER FINAL MORTAR SET (APPROX. 24 HOURS), INSTALL PACKING TIGHTLY BETWEEN EXISTING FOOTING GLASS BLOCK PANEL AND JAMB AND HEAD CONSTRUCTION. LEAVE SPACE FOR SEALING. 1 SCALE: N.T.S. J) APPLY SEALANT EVENLY TO THE FULL DEPTH OF RECESSES IN ACCORDANCE WITH THE SECTION AT DEEP MONO FOUNDATION RETROFIT FOR MISSING MSTAM STRAP MANUFACTURER'S APPLICATION MANUAL AND INSTRUCTIONS. „_ , " RETROFIT FILLED CELL DETAIL K) A MAXIMUM OF 60 SQUARE FEET OF GLASS BLOCK MAY BE INSTALLED IN ANY OPENING. �_ SCALE: 3/4 -1-0 - SCALE: 3/4 1-0 FOR WIND SPEEDS UP TO 110 MPH*, PER PITTSBURG CORNING RECOMMENDATIONS FOR SCALE: N.T.S. INSTALLATION OF GLASS BLOCK. U' _zo SIB z Q a t� z C9 a--+ ,.. O LUc1l �o v w m I� a M cM � o �o 2_0 4 Al g u7pv B D.- " �m A 'zoH � ,. ilot /yam LJ 4 v 1' c d- J UEp?g� ( ci .6N Zvi,— Ca To the best of tht7cng eer's "p�vl dg , irlfp�thatio�,and belief, the structuP rtplanso d specifithMns co d ♦, within these drawlA m t tla Building Code - Resi 6th ibw. fv ih a, signature and seal is on'lyucturgl,,44gsstng portions of the drawing pages"ki6dd�� 'Y eF B signature and seal. i O z N Ocur-, > M O M a� 0Ln V) za Q N LLn �M U vo ' _4 Q 00 z § E z w J� J �z W� za c�400 ZwW, � z� Z 0 z 0*1 oRS 00 " F- L ^, W 00 �_ z V > ZZ z C OLn L E L O LU _fu - o� ZO J a Q iU UQpQ x0 O U 0 Lo Z w di ;Q5 8 W M N Q Z z t m O 06 5 = <9 ,--i a In SCALE : AS NOTED DATE : 3/18/2018 TECH: FFLORES VERSION NO. 10 SHEET NO. SS CROSS BRACING DETAIL (TYP.) SCALE: 1/2" = 1'-0" TRUSS NOTES: CONV. FRAMED RIDGE 1. WOOD TRUSS ERECTOR SHALL PROVIDE BRACING ACCORDING TO ANSI/TP1-2014 MAY BE NAILED (TRUSS PLATE INSTITUTE) NOTE THAT THE COMBINED WIND AREA IS GREATER w/ MIN. (4) 12d WHEN BEFORE THE ROOF SHEATHING IS APPLIED, AND BRACING SHALL THEREFORE BE IT LANDS NEXT TO INSTALLED AS THE TRUSSES ARE ERECTED. INADEQUATE BRACING IS THE MOST PRE-ENG. TRUSSi COMMON CAUSE OF ACCIDENT IN WOOD TRUSS CONSTRUCTION. FULL BUNDLES OF PLYWOOD SHALL NOT BE PLACED ON TRUSSES. THIS CONSTRUCTION LOAD SHOULD BE LIMITED TO 8 SHEETS OF PLYWOOD ON ANY PAIR OF TRUSSES & SHALL BE LOCATED ADJACENT TO THE SUPPORTS. NO EXCESS CONCENTRATION OF ANY CONSTRUCTION MATERIAL (SUCH AS GRAVEL OR SHINGLES) SHALL BE PLACED ON THE TRUSSES IN ANY ONE AREA THEY SHALL BE SPREAD OUT EVENLY OVER A LARGE AREA SO AS TO AVOID OVERLOADING ANY ONE TRUSS. 2. ALL BRACING (DB,CB,BB) SHOWN ABOVE SHALL BE IN ADDITION TO CONTINUOUS LATERAL BRACING SPECIFIED BY THE TRUSS MANUFACTER ALL LATERAL BRACING SPECIFIED BY TRUSS MANUF. SHALL HAVE ADDITIONAL DIAGONAL BRACES AT 20'-0" O.C. MAXIMUM. 3. ALL BRACES SHALL BE 2X4 NOMINAL DIMENSION LUMBER & SHALL BE ATTACHED w/ (3) 12d NAILS AT EACH TRUSS INTERSECTION. 4. ADDITIONAL BOTTOM CHORD BRACING SHALL BE INSTALLED AS REQUIRED BY TRUSS DESIGN WHEREVER ADEQUATE STRUCTURAL CEILING ARE NOT ATTACHED DIRECTLY TO THE BOTTOM CHORD OF THE TRUSS. 5. PROVIDE TRUSS BLOCKING AT ALL TRUSS BEARING SUPPORTS WHERE TRUSS DEPTH EXCEEDS STANDARD HEEL HEIGHT. SEE TYP. TRUSS BLOCKING DETAILS 2X4 DIAGONAL AT 8'-0" O.C. 2X4 BLOCKING MAX & EACH END ALTERNATE BETWEEN EA. TRUSS DIRECTION TYP. —, -----/—WOOD TRUSS J A TYP. WOOD TRUSS BLOCKING DETAIL SCALE: 1 /2"=V-0" WOOD WALL OR TRUSS. SEE PLAN STRUCTURAL SHEATHING ATTACHED PER NAILING SCHEDULE VARIES W/ ROOF SLOPE 2X4 CONT. W/ (2) 16d COMMONS NAILS EACH STUD TYP. T&B —TRUSS OR ROOF SYSTEM SHEAR TRANSFER EXTERIOR. WALL SCALE: 3/4" = 1'-0" CB 1 TYP. HAND FRAMING ABOVE TRUSS 2X4 STUDS & PLATES AT 2'-0" O.C. EACH DIRECTION TYP. U.N.O. 2x8 BLOCKING NAILED @ -EACH SIDE w/ (3) 12d NAILS WHEN REQUIRED w/ (2) SIMPSON HTS20 w/ (24) 10d x 1 1/2" NAILS EACH `3 TB I PRE-ENG. TRUSS CONT. ROOF SHEATHING AT TRUSS TOP — CHORD AT ALL HAND FRAMED AREAS TYP. DIAGONAL - AT 8'-0" MAX 2X4 CONT. AT T & B CHORD TRUSS SEE ROOF PLAN SHEATHING 2X4 BLOCKING BETWEEN TRUSSES SECT. A -A PROVIDE 2X4 MIN. BLOCKING AT OF HIP/RIDGE, TYP.BETWEEN TRUSSES W/ (2) 12D NAILS EACH END TO TRUSS TOP CHORD TYP. �A TRUSS G.T. ADD 2X4 ALONGSIDE TOP CHORD WHEN REQ'D TO PREVENT PLYWOOD SPAN FROM EXCEEDING PACK MAX 24" SPAN (EITHER USSES HIP SIDE OR BOTH IF REQ'D) lei X G.T (2) 12D NAILS AT 12" O.C. MAX HIP/RIDGE BLOCKING DETAIL SCALE: 1 /2"=V-0" VERTICAL SCAB 2 x 6 #2 SPF 48" O.C. W/ (4) 10d TOP & BOTTOM OR SIMPSON H2.5A w/ (10) 8d NAILS COLLAR TIE EVERY 3rd RAFTER 2x4 SPF 2 (2) #7 x 3-1/2" WOOD SCREW EACH TRUSS OR SIMPSON H2.5A w/ (10) 8d NAILS AT 48" O.C. BEVEL CUTS (OPTIONAL) "k 2x8 #2 SPF RIDGE BEAM 2x6 #2 SYP RAFTERS FOR SPANS 4FT TO 8FT 2X4 RAFTERS FOR SPANS LESS THAN 4FT @ 2'-0"0.C. MAX. w/ (3) 10d COMMON TOENAILS TO RIDE BEAM CONC. MASONRY STEEL OR WOOD BEARING SUPPORT A -A ALTERNATE BLOCKING DETAIL @ INTERIOR BEARING 3 SCALE: 1/2" = V-0" PROVIDE BLOCKING AT ALL TRUSS BEARING SUPPORT WHERE TRUSS DEPTH EXCEEDS STANDARD HEEL HEIGHT OIL VARIES 2x4 #2 SPF BRACING @ 16" O.C. W/ (4) 12d TOENAILS TO TOP PLATE & (2) 12d END — NAILS TO TRUSS BOTTOM CHORD MIN. (2) 2x4 SPF TOP PLATE ROOF SHEATHING ATTACHED PER NAILING SCHEDULE COMMON TRUSSES. SEE TRUSS PLAN FOR CONNECTION INFORMATION. VARIES SEE PLAN FOR WALL LOCATION �— MIN. 2x4 #2 SPF STUDS @ 16" O.C. W/ EXTERIOR SHEATHING ATTACHED PER NAILING SCHEDULE & (3) 12d TOENAILS TO SEE PLAN FOR PLATE BELOW TOP OF WALL o MIN. 2x4 #2 SYP P.T. PLATE °. W/ 1/2"X8" EPDXY ANCHOR MASONRY WALL SEE @ 3" FROM EACH END & PLAN FOR MORE p 16" O.C. MAX. INFO. ° SECTION @ ENTRY 8 SCALE: 3/4" = V-0" SIMPSON LSTA18 W/ (12) 10d NAILS CENTERED AT SPLIT TO TIE BEAMS TOGETHER SEE FLOOR PLAN FOR COLUMN SIZE & ADDITIONAL INF( (2) 2x8 #2 SYP w O.S.B. FLITCH PI TOP @ TRUSS E U.N.O. ON ROOF PLAN TYPIC WALL NOTE: PENDING BEAM BEARING LOCATION, THE BEAM CAN SIT ON TOP OF COLUMN w/ (2) SIMPSON HTS20 w/ (24) 10d x 1 1/2" NAILS EACH SIMPSON HU46/HUC46 w/ (8) 16d NAILS TO POST & (4)10d NAILS TO BEAM SUPPORT COLUMN BUILT-UP (2) 2x4's OR 4x4 w/ (2) 10d NAILS @ 8" O.C. EACH PLY (SHOWN AS 4 x 4) (2) SIMPSON HETA20 w/ (8) 10d x 1 1/2" NAILS EACH - OR (2) SIMPSON MSTAM36 w/ (7) 10d & (4) 1/4"x2 1/4" TITENS EACH TIE BEAM BEAM @ RAISED ENTRY 2 MASONRY WALL 4 SCALE: 1/2" = V-0" )IMPSON HUC410 w/ 6d INTO HEADER & ( Od INTO BEAM - SEE tOOF PLAN FOR MOI VFO SEE FLOOR PLAN FOR SEE PLAN FOR CANT. COLUMN SIZE & BASE �7/16" OSB FLITCH PLATE CONNECTION INFO REQ'D ONLY WHEN INDICATED ON BM. 7/16" OSB FLITCH PLATE SEE FLOOR PLAN FOR SCHEDULE/PLAN REQ'D ONLY WHEN COLUMN SIZE & BASE OPTION A INDICATED ON SC EDULE/PLANM OPTION B CONNECTION INFO OPTION C. COMMON BM._ TO POST ATTACHMENT KA SEE ROOF PLAN FOR BEAM SIZE & CONNECTION INFO. SIMPSON MTS18 w/ (14) 10d NAILS TYP. U.N.O. SEE FLOOR PLAN FOR — COLUMN SIZE & ADDITIONAL INFO. (WOOD COLUMN SHOWN) A A SEE PLAN FOR SEE PLAN FOR CANT. IF INDICATED CORNER SEE FOUNDATION PLAN FOR MORE INFO 5" COMMON BM. ATTACHMENT 2x4 STUDS w/ SIMPSON SP1 w/ (10)10d NAILS AT BASE SEE J/S6 FOR MORE INFO. SCALE: 3/4"=V-0" EXTERIOR SHEATHING ATTACHED PER NAILING SCHEDULE 2x4 BASE PLATE W/ SIMPSON LSTA30 w/ (22) 10d NAILS OR SIMPSON MTS12 w/ (14) 10d x 1 1/2" NAILS TO FLOOR GIRDER BELOW @ 16" O.C. 16" FLOOR SYSTEM —' FLOOR GIRDER SEE PLAN FOR SEE PLAN FOR DIRECTION CONNECTION SECTION @ FLOOR CONNECTION 22 SCALE: 3/4" = 1'-0" SCALE: 3/4"=1'-0" SEE VS5 FOR ADDITIONAL OUTLOOKER INFO. 1/2" PLYWOOD (2) 16d NAILS TO EACH COMMON TRUSS/ FRAMING TYP TOP & BOTTOM \../ BM. SPLICE OVER �� CENTER OF POST MIDDLE [— SEE PLAN FOR 8d NAILS AT VALLEY TRUSS 4" O.C. INFO. �• MASONRY WALL BELOW: SIMPSON °.. HETA16 w/ (9) 10d x 1 1/2" NAILS @ MASONRY WALL 4'-0" O.C. TO GABLE TRUSS OR BEAM z . BEAM BELOW: SIMPSON HTS20 w/ SEE TRUSS PLAN a (24) 10d x 1 1/2" NAILS @ 4'-0" O.C. TO GABLE TRUSS a COMMON TRUSS ° SEE ROOF PLAN FOR CONNECTION SECTION AT HIP GABLE 12 SCALE: 3/4" = V-0" EXTERIOR ATTACHED SCHEDULE JACK TRUSS (AS SHOWN) OR GABLE END SEE TRUSS LAYOUT CLIP EACH TRUSS (SEE ROOF PLAN FOR TYPE) FRAME OUT TO BLOCK EDGE SEE DETAIL 4/D1 FOR BEAM SIZE 2x SPF #2 AT 16" O.C. BUILDER FRAME RADIUS AS REQUIRED KNEEWALL ENTRY FRONT WALL s SCALE: 1/2" = V-0" 2X4 #2 SYP NAILER. NAIL TO STUDS w/ (3)16d AT EACH STUD - TOENAIL EACH TRUSS TO NAILER w/ (3)10d ROOF AND EXTERIOR SHEATHING ATTACHED PER NAILING SCHEDULE SEE 2ND FLOOR WALL SECTION FOR ADDITIONAL INFORMATION SIMPSON LUS26 w/ (8)10d NAILS OR IF 2 PLY TRUSS SIMPSON LUS26-2 w/ (8)16d NAILS TO v SEE FLOOR FRAMING PLAN LEDGER AND J/S6 FOR MORE INFO, 2X10 #2 SYP CONT. LEDGER w/ (3) VERIFY WITH PLAN FOR LOCATION AND DIRECTION 1/2" X 41/2" LAG SCREWS ATTACH (IF PARALLE SEE 202 FOR LAG SCREWS INTO END OF EACH BLOCKING INFO) FLOOR TRUSS, 24" O.C. MAX. (AT EACH SIDE OF G.T. INSTALL (4) LAG MASONRY WALL SCREWS EACH SIDE) (TYPICAL) SECTION AT LOW ROOF 9 SCALE: 1/2" = V-0" LOW ROOF/WALL SHEATHING ATTACHED PER NAILING SCHEDULE 2x STUDS @ 16" O.C. w/ SIMPSON SP1 w/ (10) 10d NAILS AT BASE & SIMPSON SP2 w/ (12) 10d NAILS AT TOP 2x BLOCKING BETWEEN STUDS TO TRUSS W/ (2) 12d TOENAILS EACH END ( BETWEEN TRUSSES (2) 12d NAILS TO EACH VERTICAL STUD) 2x BASE PLATE W/ (2) 12d NAILS @ 16" O.C. ALONG W/ SIMPSON MTS12 w/ (14) 10d x 1 112" NAILS TO BLOCKING BELOW @ 16" O.C. PLYWOOD FLOORING LOW ROOF TRUSS W/—' L (2) 2x6 BLOCKING UNDER FLOOR G.T. RAISED BOTTOM CHORD 2nd FLOOR WALL w/ SEE PLAN EXTENSION SEE TRUSS SIMPSON LUS24-2 w/ (16) MANUF. SPEC'S FOR 16d NAILS AT EACH END CONNECTIONS TO G.T. SECTION @ BUMP OUT 39 SCALE: 3/4"=1'-0" INI'_� DETAILS &SECTIONS (D z_o z�z a V) C9 c a--+ W 0 c -a)t�) E t!) ~ U o 0 m N M ly M C N C! O o n' _ U §"co in'�.o at ��LO ¢� Sao B Do = J{ N_ M .�pt fiMfg9 . 41 �1 •`C ®�� 'ice ���`. LJ `9L1 To the best o Engineer's Aowledg$, infgr i�1 d belief, the stru MY. pla� d.s�.etifica�il?-Ron within thesedram(R 7F�( 0m j+witb.'ttie"20 Building Code - Resid Edition. €n�jl�� F s signature and seal is only fd tl}A iti9' ura `engineering portions of the drawing pages bearing Engineer's signature and seal. 1f O Z N N 0 .a+ F 4 H M O M V) '41-11 gyp Q Ln a •L N H1 �En fl- .-S z � �3a00 Q � z E W J d' Z W za f F �?OU �BZ� z �°8 O1 00 cn �® o (V 00Z �o C W p U ;� = o� 0 V / QW Lu Q M �O�a0- d:l iz <W� 6L. Z 1 V' ` I j J r-1 UJI Q EJJ g Z Q 8 Z $az N co N Z rn O 06 .-E g a = U) W 11 SCALE : AS NOTED DATE : 3/18/2018 TECH: FFLORES VERSION NO. 10 SHEET NO. D1 (1) SIMPSON LSTA30 w/ (22) (2)-12d GABLE END FLOOR SEE SS FOR RETROFIT 10d NAILS BENT OVER TOP SIMPSON SP4 w/ (6) 10d x 1 1/2" TOENAILS 2x4 TRUSS SEE R/S6 FOR CONNECTION IF MSTAM36 1 OR 2 PLY GIRDER PLATE THEN DOWN THE (USE SP6 FOR 2x6 WALL, USE SP8 TO TRUSS TOP CONNECTION INFO TO CAN NOT BE INSTALLED / TRUSS. SEE PLAN FOR FACE OF HEADER/STUDS FOR 2x8 WALL) MASONRY WALL CONNECTION. @ 24" O.C. NJ EXT. SHEATHING QA BELOW AND ALT. SEE PLAN FOR CONN. 2x 2x CRIPPLES 16" O.C. PP (2) 2x SPF TOP PLATE FLUSH W/ TOP 2 BLOCKING INFO 2 TOENAILS T/B ( ) (2) 2x HEADER SEE PLAN SEE FOR ° BLOCKING OF MASNORY & 8d NAILS T/B FLANGE zo 1. APPLY SUB (3) 2x # SPF (2) 10d TOENAILS AT EA. INTERIOR HEADER DETAILS FLOOR + STUDS w/ 10d @ 2 2x SPF TOP PLATE () END OF SILL. MAX. (1) 2x SILL PLATE W/ (2) 12d TOENAILS. 2x STUDS © ADHESIVE TO 8 O.C. EACH SIDE OPENING WIDTH 4 FEET. EXTERIOR HEADERS • 2x4 CONTACT U.N.O. ON PLAN IF OPENING IS GREATER (1) 2x SILL PLATE W/ (2) 12d TOENAILS. • • ;o SURFACE OA 2x4 #2 BLOCKING THAN 4 FEET BUT NOT OPENING LARGER THAN 4 ft (2) 2x FLOOR SYSTEM SEE PLAN NOTE: VERIFY WITH FLOOR FRAMING PLAN FOR I -JOIST B 2x4 SIDE BRACE AT 48 O.C. EXCEEDING 6 FEET. A SIMPSON LS30 w/ 6 10d x 1 1/2" CLIP IS TO BE SILL PLATE w/ SIMPSON LS30 w/ (6) 10d x 1 1/2 CLIP EACH SIDE =74 OR FLOOR TRUSS FOR BETWEEN JOISTS 2X CONT. RIBBON INSTALLED AT EA. END MIN (3) 2x #2 SPF STUDS @ END OF ; ; G.C. VERIFY INTERIOR CORRECT BLOCKING REQUIREMENTS wl (3) 12d EA. END TO HORIZ. FLOOR DECK HEADER SEE Q/S4 FOR REQ'D JAMB INF 1/2" GYP. BOARD OR BLOCKING TYPICAL BLOCK WALL 2x CRIPPLE AT EA. SIMPSON LSTA30 w/ (11) 10d (2) SIMPSON MSTAM36 STRAPS w/ (7) 10d NAILS & (4) 1/4" x 2 1/4" TITENS CENTERED EXTERIOR STRUCTURAL SHEATHING 7/16") 1-1/8" RIM BOARD FLOOR TRUSS/ END OF OPENING TO STUDS ABOVE PLATE (MIN. NAILED TO STUD • ON FLOOR SYSTEM TO MASONRY WALL •°•°• VERIFY W/ PLAN 8d NAILS @ 3" O.C. JOIST SEE PLAN (2) SIMPSON MSTAM36 w/ I -JOIST SEE PLAN PACK w/10d NAILS FLOOR DECK BELOW, IF WOOD WALL IS BELOW USE (2) SIMPSON MSTA36 STRAPS w/ (26) 10d WALL SHEATHING (2) 12d TOE NAILS TOP (7) 10d NAILS & (4) 1/4"x2 TIE BEAM @ 8"o.c. FLOOR TRUSS/ WOIST SEE PLAN NAILS (G.C. TO INSURE SOLID BLOCKING TO RIM BOARD & BOTT. CHORD 1/4" TITENS SIMPSON LSTA30 FROM WIN W IS INSTALLED). SCALE: 1 1/2" =1'4' AJS BLOCKING PANEL @ 24" JAMB TO FLOOR TRUSS/ SOLID O.C. (MAX) AND @ EACH PROVIDE BLOCKING BLOCKING BELOW. SCALE:3/4" =1' - 0" SEE SS FOR RETROFIT GABLE END RIM JOIST END OF WALL UNDER BELOW JAMBS SEE 8/D-2 FOR ALT. CONDITION. DETAIL TO BE CONNECTION IF MSTAM36 SEE R/S6 FOR CONNECTION INFO TO CORNERS FOLLOWED IF DOWN SET OR BOX HEADER IS USED SECTION CORNER CAN NOT BE INSTALLED MASONRY WALL (2) - 10d TOE NAILS EACH SIDE OTHERWISE DETAIL CAN BE IGNORED FRAMING ATTACHMENT 1 BLOCKING DETAIL 2 GIRDER/COL. CONN. @ 2nd FLOOR HEADER CONN. @ 2nd FLOOR 3 4 SCALE: 1/2" = 1'-0" AS NOTED SCALE: 3/4" = V-0" SCALE: 1/2" = 1'-0" SEE Q/S4 FOR SIMPSONSEE SP4 w/ (6) 10d x 1 1/2 SP6 FOR AO SIMPSON SP2 w/ (12) 10d NAILS JAMB STUD SS FOR RETROFIT SEE 8/D-2 FOR ALT. CONDITION. DETAIL TO BE CONNECTION IF MSTAM36 FOLLOWED IF DOWN SET OR BOX HEADER IS USED 2x6 / 2x8 CRIPPLES @ 16" O.C. (2) 2x8 OR (2) 2x6 TOP 2x6 WALL, USE SP8 FOR 2x8 WALL)@ 24" O.C. REQ'D TYP4 .C. BO SIMPSON LSTA24 w/(18) 10d NAILS CAN NOT BE INSTALLED OTHERWISE DETAIL CAN BE IGNORED NOTCHED AT HEADER LOCATION SEE INFO BELOW ON CONNECTION PLATE SEE PLAN o•.oo•. o.o• o.o OF CRIPPLES IF LONGER THAN 8" P. 2 - 2 x 4 SPF O SIMPSON CS16 w/MIN. 12" END SIMPSON SP4 w/ (6) 10d x 1 1/2" (USE SP6 FOR 2x6 WALL, USE SP8 FOR 2x8 WALL) 24" O.C. SEE PLAN FOR CONN. TALL. CONTRACTOR MAY USE RTT ( A TOP PLATES LENGTH ON STUDS W/ (11) 10d (1) SIMPSON LSTA30 w/ (22) 10 @ CLIPS) NAIL BACK LEG OF CIPPLE TO (2) 2x HEADER TO SIT NAILS TO STUDS ABOVE & (11) 10d NAILS BENT OVER TOP PLATE (2) - 2X SPF TOP PLATE HEADER w/ (2) 12 TONEAILS FLUSH w/ THE OUTSIDE NAILS TO STUDS BELOW. THEN DOWN THE FACE OF SEE PLAN FOR SIZE 2 x 4 #2 SPF STUDS C„ AT 16 O.C. U.N.O. OD SIMPSON SP1 w/ (10) 10d NAILS HEADER/ STUDS (2) 2x HEADER SEE PLAN HEADER FLUSH TO OUTSIDE 2x6 / 2x8 WALL BEYOND SEE o INTERIOR HEADER NAILING AREA (TYP.) FLOOR PLAN FOR HEADER G (2) 2x HEADER SEE PLAN OE 5/8" A.B. 24" O.C. AND 6" FROM MIN (3) 2x #2 SPF STUDS @ (1) 2x SILL PLATE W/ (2) 12dTOENAILS. EXTERIOR HEADERS SEE PLAN FOR COL. SIZE CONNECTION j` @ END OF HEADER SEE Q/S4 FOR (2) SIMPSON MSTA36 STRAPS w/ SEE STANDARD HEADER EACH END W/ 7" EMBEDMENT. IF REQ'D JAMB INFO (1) 2x SILL PLATE W/ (2) 12d TOENAILS. (26) 10d NAILS DOUBLE 2x6 OR 2x8 TOP CONNECTION DETAILS FOR AT STEP DOWN LOCATION, MIN 7 2 x SPF EMBEDMENT PAST STEP. OPENING LARGER THAN 4 ft (2) 2x SILL PLATE SIMPSON LS30 PLATE SEE PLAN MORE INFORMATION .j BASE PLATE w/ w/ 6 O FLOOR SYSTEM OR 12d NAILS AT 6" SIMPSON SP4 w/ (6) 10d x 1 1/2 PRE-ENGINEERED O " (USE 2x CRIPPLES @ 16" O.C. W/ 12d TOENAILS T/B 10d x 1 1/2" EACH SIDE 10d TOENAILS AT EACH END OF 2-STY. FRAMING O.C. TYP T & B SIMPSON SP6 w/ (6) 10d x 1 1/2" SP8 FOR 2x8 C B H B C FLOOR SYSTEM SP6 FOR 2x6 WALL, USE SP8 FOR 2x8 (2) (2) BAND JOIST & BLKG. (2) 2 x #2 (USE SILL (MAX. OPENING WIDTH 4 FEET). WALL) @ 24" O.C. EWALL OR BEAM WALL) AT EACH STUD AT HEADER / IF OPENING IS GREATER THAN 4, OR LVL GIRDER SYP U.N.O. JAMB CONDITION OR IF BUILT-UP (2) - 2 x 4 SPF STUDS ARE WIN WALL SYSTEM A.B. TO 2X CRIPPLE AT EACH END OF FEET BUT NOT EXCEEDING 6 FEET, BLOCK SOLID ( ) TOP PLATES BE SPACED W/IN 6 FROM OPENINGS OPENING NAILED TO STUDW___ A SIMPSON LS30 w/ (6) 10d x 1 1/2" IS BE INSTALLED AT EACH END. SEE PLAN FOR 2 x CONT. T & B AND MULTIPLE STUD PACKS PACK W/ 10d NAILS @ 8"O.C.O COL. SIZE 2 x 4 #2 SPF STUDS B G INTERIOR HEADER O TYPICAL BLOCK WALL PLYWOOD ATTACHED PER NAILING SCHEDULE SIMPSON HTT4 w/ (18) AT 16" O.C. U.N.O. (2) 2x HEADER G (1) 2x SILL PLATE W/ (2) 12dTOENAILS. EXTERIOR HEADERS FLOOR TRUSS/ I -JOIST SEE PLAN 16d NAILS & 5/8 „ ANCHOR BOLT w/ BOX HEADER SEE PLAN E F TYp F F D (1) 2x SILL PLATE W/ (2) 12d TOENAILS. 2 x 4 P.T. OPENING LARGER THAN 4 ft (2) 2x SILL PLATE PLATE SIMPSON MSTAM36 W/ (7)�� 10d NAILS & (4) 1/4"x2 1/4" TAPCONS IE BEAM MIN. 6 EMBEDMENT (2) SIMPSON LSTA12 w/ (10) 10d NAILS WRAPPED UP AND (2) 2x TOP PLATE 2x CRIPPLES @ 16" O.C. w/ .BASE W/ SIMPSON LS30 w/ (6) 10d x 1 1/2" EACH SIDE PROVIDE BLOCKING OVER TOP PLATE SIMPSON SP2 w/ (12) 10d NAILS AT SEE FOUND. PLAN FOR FTG. REQ, H STUDS UNDER 2nd FLOOR HEADER ARE O BELOW JAMBS tl NAILS AT BASE ON SP1 w/ (10) 10d NOT REQ'D TO HAVE CONNECTIONS. • < •' • *PROVIDE (2) CRIPPLES BELOW ATTACH STUDS w/ (3) 12d TOENAILS T&B SEE FOUNDATION PLAN TO ANY GIRDER TRUSS IN THIS 2 ST. I NT. BEARING WALL FOR FTG. REQ. 2x CRIPPLES TO SITUATION. CONNECT G.T. TO PROVIDE EXTERIOR SHEATHING MATCH JACK STUDS w/ (2) SIMPSON HTS20 w/ AND EXTERIOR ATTACHED PER NAILING SCHEDULE FOR EXTERIOR 2 STORY WALLS ONLY. HEADER CONN. @ 2nd FLOOR STUDS BELOW (24) 10d x 1 1/2" NAILS AT TOP AND 5 SHEATHING CAN STOP ONCE UNDER s 2 STORYBOTTOM COL. aC� GIRDER TO HEADER 7 (IF CRIPPLES ARE LESS THAN 8 SCALE: 1/2" = 1'-0" LOWER ROOF. SYSTEM 42 SCALE: 1/2" = V-0" LONG NO STRAPS ARE REQ'D) SCALE: 1/2" = 1'-0" o.°.o. o.°.o ADDITIONAL STRAPS SEE STANDARD HEADER REQUIRED AT TOP PLATE SEE SS FOR RETROFIT SEE 8/D-2 FOR ALT. CONDITION. DETAIL TO BE CONNECTION DETAILS FOR X TO STUDS TO MATCH CONNECTION IF MSTAM36 FOLLOWED IF DOWN SET OR BOX HEADER IS USED MORE INFORMATION HEADER STRAPS CAN NOT BE INSTALLED OTHERWISE DETAIL CAN BE IGNORED (2) SIMPSON LSTA24 w/ (18) 10d NAIL (2) 2x HEADER SEE PLAN SEE 8/D-2 FOR ALT. CONDITION. DETAIL TO BE FOLLOWED IF DOWN SET OR BOX HEADER IS USED (2) SIMPSON LSTA30 w/ (22) SIMPSON SP4 w/ (6) 10d x 1 1/2" (USE SP6 FOR 2x4 STUDS MIN (3) 2x #2 SPF STUDS @ END OF HEADER OTHERWISE DETAIL CAN BE IGNORED 10d NAILS BENT OVER TOP 2x6 WALL, USE SP8 FOR 2x8 WALL) @ 24" O.C. PER PLAN SEE Q/S4 FOR REQ'D JAMB INFO PLATE THEN DOWN THE 2) 2x HEADER SEE PLAN SIMPSON LS30 w/ 6 10d x 1 *FOR 1/2" NAILS AT EACH END TYP. FACE OF HEADER/STUDS DOUBLE 2x4 OPENINGS LESS THAN 4'-0" WIDE, SILL MAY BE SIMPSON LSTA30 w/ (22) 10d SIMPSON SP4 w/ (6) 10d x 1 1/2" (USE SP6 FOR 2x CRIPPLES @ 16" O.C. • TOP PLATE ATTACHED w/ (2) 16d TOENAILS AT EACH END NAILS BENT OVER TOP PLATE 2x6 WALL, USE SP8 FOR 2x8 WALL) @ 24" O.C. W/ (2) 12d TOENAILS T/B THEN DOWN THE FACE OF INTERIOR HEADER 2 WS 10d @ (2) 2x SILL PLATE HEADER/ STUDS (2) 2X SPF TOP PLATE MIN (3) 2x #2 SPF STUDS (1) 2x SILL PLATE W/ (2) 12dTOENAILS. 30/ " FAT 2x CRIPPLES @ 16" O.C. (2) 2x HEADER SEE PLAN @ END OF HEADER. SEE EXTERIOR HEADERS Fib L9T��82�Q W/ (2) 12d TOENAILS T/B INTERIOR HEADER Q/S4 FOR REQ'D JAMB (1) 2x SILL PLATE W/ (2) 12d TOENAILS. r0 TOP SPLICE 2x STUDS @ 16" O.C. (1) 2x SILL PLATE W/ (2) 12dTOENAILS. INFO. OPENING LARGER THAN 4 ft (2) 2x iGjjN A (2) 10d TOENAILS AT EACH EXTERIOR HEADERS SILL PLATE w/ SIMPSON LS30 w/ (6) END OF SILL (MAX. OPENING (1) 2x SILL PLATE W/ (2) 12d TOENAILS. OPENING 2x CRIPPLE AT EACH END OF 10d x 1 1/2" EACH SIDE WIDTH 4 FEET). IF OPENING LARGER THAN 4 ft (2) 2x SILL PLATE W/ SIMPSON OPENING NAILED TO STUD ALT. HEADER ANCHOR IS GREATER THAN 4 FEET LS30 w/ (6) 10d x 1 1/2" EACH SIDE PACK W/ 10d NAILS (2) 10d TOENAILS AT EACH END OF 8 BUT NOT EXCEEDING 6 FEET, SILL (MAX. OPENING WIDTH 4 FEET).15- A SIMPSON LS30 w/ (6) 10d x 1 MIN (3) 2x #2 SPF STUDS @ END TYPICAL BLOCK WALL IF OPENING IS GREATER THAN 4, PROVIDE 2x4 ON • SCALE: N.T.S. 1/2" IS TO BE INSTALLED AT OF HEADER SEE Q/S4 FOR FEET BUT NOT EXCEEDING 6 FEET, EACH END REQ'D JAMB INFO A SIMPSON LS30 w/ (6) 10d x 1 1/2" IS TOP OF 2x8 TO 2x CRIPPLE AT EACH SIMPSON LSTA30 w/ (22)10d NAILS SIMPSON (2) MSTAM36 w/ (7) 10d NAILS & (4) 1/4"x2 1/4" TO BE INSTALLED AT EACH END • BLOCK OUT TOP. PLATE ATTACH Ile END OF OPENING 1 CENTERED TAPCONS W/ (2) 10d NAILS NAILED TO STUD PACK FLOOR DECK FLOOR DECK @ 3" O.C. 2x4 BEYOND DOUBLE W/ 10d NAILS @ 8"o.c. - AGAINST 2x8 ol 2x8 TOP FLOOR TRUSS/ I -JOIST SEE PLAN PROVIDE BLOCKING FLOOR TRUSS/ I -JOIST SEE PLAN STUDS PLATE SEE PLAN FOR BEAM SIZE & CONNECTIONS BELOW JAMBS2x8 TIE BEAM 2X CONT. RIBBON STUDS PER PLAN 2x4 W/ 2 ROWS NOTE: OF 10d NAILS PLATE LENGTHS MUST BE @ 3" O.C. HEADER CONN. @ 2nd FLOOR HEADER CONN. @ 2nd AT LEAST 4'-0" LONG. TYPICAL W/ HIGH BM FLOOR [DOUBLE STRAP] TOP PLATE SPLICE DETAIL 9 10 11 SCALE: 1/2" = 1'-0" SYSTEM 42 SCALE: 1/2" = 1'-0" SCALE: 3/4" = 1'-0" (D U]m zo —� z� z a U) z LU O u-' c e om U ll! �� TO M C N N U Ltj tl- � tn C, o 0 ¢ ao BDO N -C� ,01 - , Iltctt� UF o Z �1` <, Ord' a O LL$ N tlO• Q �P �S - -Z. To the best of the ee ����QQ•wledge, info ,{r[I ar�S, belief, the structural antltjijpi� i6p� kdrftein t within these drawings plI��,,wit,�hy t e 0 7 Flo 5`' Building Code - Residential 6ttiMpjtjlp�[q�i� signature and seal is only for the s{rUt ,Y�I ngineering portions of the drawing pages bearing Engineer's signature and seal. O Z CO OWN OO F!—I M M QU-)'gypLn zz � vNi•�n Q C U_ Ln V fl-00 < a E `-0 Z W J� d' �R W� za z r�=w �tY�J E8 0*1 o 00 � ` • L > 00 Z O go Fz Z Grz U z 'a 1 a W (> U f J o 9 CL Quo 9 N ILL] Z V W 0 ON ,^-i Fy u J Ln Q LLJ Z� a o z N N Z Z m o g W f SCALE : AS NOTED DATE : 3/18/2018 TECH: FFLORES VERSION NO. 10 SHEET N0. D2 FOLD UP WEATHER RESISTIVE BARRIER & TEMPORARILY SECURE WEATHER RESISITIVE BARRIER TAPE EXTERIOR 3 SHEATHING (RSREMBLED NANDOW) z' WOOD FRAME CONSTR. SELF -ADHERED FLASHIh BY LAPPING DOWN - OVER RIM JOIST AND UP WALL BY 6 IN. CE WEATHER Z ' RESISITIVE BARRIER SEAL TOPS OF JOI; UNDER DECKING SELF -ADHERED FLASHING (SEE DETAIL WP07) HEAD FLASHING TIE-IN INSTRUXTIONS: 1. Cut, fold up & temporarily secure weather resistive THESE DETAILS ARE GENERIC AND barrier above header to allow for flashing installation MEANT TO SHOW GENERAL FLASHING 2. Self -adhered flashing plus head flashing under AND WATERPROOFING METHODS TO weather resistive barrier BE USED. 3. Fold weather resistive barrier back over head flashing and seal with tape SELF -ADHERED FLASHING Scale: NTS FLANGED WINDOW FLASHING INSTALLATION AFTER WEATHER RESISTIVE BARRIER EXTERIOR SHEATHING REFER TO TECHNICAL LETTER ON CHEMICAL COMPATIBILITY SELF -ADHERED FLASHING -i DO NOT FLASH OVER BOTTOM NAILING FLANGE NAILING FLANGE SELF -ADHERED FLASHING HALF ROUND WINDOW 1-LI.1V1111\V 1 Lr1V1 Itl\V 1� SELF -ADHERED FLASHING WEATHER RESISTIVE BARRIER DOOR ROUGH OPENING 3/4"-l" BEAD OF CONSTR. ADHESIVE TO BE APPLIED UNDER THRESHOLD OF DOOR AND RETURN UP JAMB 6". USE LIQUID NAIL BRAND OR EQUAL WEATHER PROOF CAULKING T SELF -ADHERED FLASHING SUBFLOOR SELF -ADHERED FLASHING EXTERIOR DOOR WITH DECK - SECTION A EXTERIOR SHEATHING 3/4"A" BEAD OF CONSTR. ADHESIVE TO BE APPLIED UNDER THRESHOLD OF DOOR AND RETURN UP JAMB 6". USE LIQUID NAIL BRAND OR EQUAL WEATHER PROOF CAULKING SECTION -A (SEE DETAIL SELF -ADHERED FLASHING SEAL TOPS OF JOISTS UNDER DECKING (SEE DETAIL WP07) O SELF -ADHERED FLASHING EXTERIOR DOOR WITH DECK SHEATHING E Q3 1 AM SELF -ADHERED FLASHING 3" MIN O RIM JOIST INSTALL SELF -ADHERED FLASHING JAMB & HEAD FLASHING, SEE FLANGED WINDOW (SEE DETAIL WP01) SELF -ADHERED FLASHING, EXTEND A MINIMUM 6" VERTICALLY FROM BOTTOM OF THRESHOLD SELF -ADHERED FLASHING PATCH SELF -ADHERED FLASHING 8 2 1 2 4 5 WINDOW UNIT SLOPE 0.3 in: 12.0 in (0.6 cm : 30.5 cm) SELF -ADHERED FLASHING EXTERIOR CEMT. FIN. BUILDING PAPER WIRE LATH O SELF -ADHERED FLASHING CEMT. FINISH SILL/ POTSHELF/ CHIMNEY SHOULDER MECHANICALLY FASTEN IF RUBBERIZED ASPHALT RUBBERIZED NEEDED IN CORNERS / ASPHALT ADHESIVE ADHESIVE THROUGH SELF -ADHERED FLASHING SELF -ADHERED FLASHING �I 0 SELF ADHERED FLASHING INSIDE CORNER SCORED RELEASE PAPER (BEFORE FOLDING, SCORE RELEASE PAPER TO EXPOSE ADHESIVE AS SHOWN) -(Ground (� SELF -ADHERED FLASHING SELF -ADHERED FLASHING Me, FOUNDATION WEEP SCREED DECK JOIST OUTSIDE CORNER 0 0 0 Water Resistant Barrier Lath Sheathing Stucco FLASHING REQUIREMENTS R609.1 Flashing, Sealants and Weatherstripping. Flashing and sealants for exterior windows shall comply with Section R703.8. R703.2 Weather -resistant sheathing paper. One layer of No.15 asphalt felt, free from holes and breaks, complying with ASTM D 226 for Type 1 felt or other approved water -resistive barrier shall be applied over studs or sheathing of all exterior walls. Such felt or material shall be applied horizontally, with the upper layer lapped over the lower layer not less than 2 inches (51 mm). Where joints occur, felt shall be lapped not less than 6 inches (152 mm). The felt or other approved material shall be continuous to the top of walls and terminated at penetrations and building appendages in a manner to meet the requirements of the exterior wall envelope as described in Section R703.4 Exception: Omission of the water -resistive barrier is permitted in the following situations: 1. In detached accessory buildings. 2. Under exterior wall finish materials as permitted in Table R703.4 3. Under Paperbacked stucco lath when the paper backing is an approved water -resistive barrier. R703.4 Flashing. Approved corrosion -resistant flashing shall be applied shingle -fashion in a manner to prevent entry of water into thewall cavity or Penetration of water to the building structural framing components. Self -adhered membranes used as flashing shall comply with AAMA 711. The flashing shall extend to the surface of the exterior wall finish. Approved corrosion -resistant flashings shall be installed at all of the following locations: 1. Exterior window and door openings. Flashing at exterior window and door openings shall extend to the surface of he exterior wall finish or to the water -resistive barrier for subsequent drainage. Flashing at exterior window and door openings shall be installed in accordance with one or more of the following or other approved method: 1.1 The fenestration manufacturer's written flashing instructions. 1.2 The flashing manufacturer's written installation instructions. 1.3 In accordance with FMA/AAMA 100, FMA/AAMA 200, or FMA/WDMA 250. 1.4 In accordance with the flashing method of a registered design professional. 2. At the intersection of chimneys or other masonry construction with frame or stucco walls, with projecting lips on both sides under stucco copings. 3. Under and at the ends of masonry, wood or metal copings and sills. 4. Continuously above all projecting wood trim. 5. Where exterior porches, decks or stairs attach to a wall or floor assembly of wood -frame construction. 6. At wall and roof intersections. 7. At built-in gutters. R703.6.2.1 Weep Screeds A Minimum 0.019-inch (No. 26 Galy. sheet gage), corrosion -resistant weep screed or plastic weep screed, with a minimum vertical attachment flange of 3 1/2" shall be provided at or below the foundation plate line on exterior stud walls in accordance with ASTM C 926. SELF -ADHERED FLASHING PRODUCTS DETAILS TWO LAYERS OF FELT OR ONE LAYER OF HOUSE WRAP AND ONE LAYER OF FELT ARE REQUIRED BEHIND STUCCO. FBC R703.2.1 Detail Instructions Refer to the number marked as ## in each detail that corresponds to the numbered items in the list of instructions below: 1. Install self -adhered flashing in order as shown by numbers 2. Install flashing and weather resistive barrier to form water shedding laps 3. Self -adhered flashing can be substituted for building paper 4. Split the release paper using the ripcord (Split release on demand, embedded in the adhesive layer) - for ease of installation and to minimize scoring cuts 5. Remove all release paper per standard installation instructions and adhere to substrate using a square piece of flashing material (6" x 6" Minimum) 6. Fold as shown by arrows 7. Angle of corner may vary, adjust folding of the flashing accordingly to fit tight to comer 8. Mechanically fasten as necessary Cement Plaster in accordance with ASTMC926 over wood 2nd floor Cement Plaster over block 1 st floor - 7/8" Cement Plaster in accordance With ASTMC926 - Felt backed metal lathe in accordance With ASTMC1063 Building Paper -7/16" O.S.B. sheathing Metal Flashing Weep Screed Installed As Per Manufact. Specs. Maintain Bottom of Weep Screed 1 1/2" to 2" Above Roof Sheathing Note: The building paper and metal lath must be installed over the top of the weep screed. WEEP SCREED DETAIL NOT USED NOT USED NOT USED SCALE: NOT TO SCALE 7/8" Cement Plaster in accordance with ASTMC926 Felt backed metal lathe in accordance with ASTMC1063 Building Paper 7/16" O.S.B. sheathing Stampede or similar cauk bottom joint only Weep Screed Installed As Per Manufact. Specs. 1/2" Cementitious Decorative Finish All inside and outside corner will need to be miter cut and caulked all butt joints need to becaulked using Stampede or sim. caulk for all UI Z Z z a t) iD v, w -V - Oclof ITU 3 W W C t6 Cl) Cn o oN U� L LLco 00 �ni; ¢A Age Al B DO N µC� N N op� c o p O N p M M Z O c rA Z _J ? Z W c � F. to LL N E LU L� a 6- W -� a U_ ii W U a&- g z rn W 'S Z 0 m°¢ O O LLZE cp 01 Q � o __J W � A % 0 O U U 1,- 0 0 To the best of the Engineer's knowledge, Information, and belief, the structural plans and specifications contained within these drawings comply with the 2017 Florida Building Code - Residential 6th Edition. Engineer's signature and seal is only for the structural engineering portions of the drawing pages bearing Engineer's signature and seal. 0 0 Z N Opt\ Z I> Ul „ M Q � M Ln a cn•�� 0 Q " LL oC U fu tQ E Z WJ C:) d- za f< $ O U u, Z �lW Cl) OJ 0 m ¢ �o® L N LU o � oc Z X (V LL O v, 3 o "d 'a L n O CC X g Q �,. a LIJyob ~YP 86 ¢ O Q � of a�Wo Z ,� ,o W Lli LJ.j tQ � 23 J �-{ 8 N Q Z~ N Z 0 G0 06 15_ J 0 ¢ 9 ui rn ,-1 a cn 2: SCALE : AS NOTED DATE : 3/18/2018 TECH: FFLORES VERSION N0. 10 SHEET NO. W P O O '40 �X 3AW CO A3 FL17244.1 ESR-3455 A23 FL10448.2 ESR-2506 .4., Cn HD210-2 FL17232.3 ESR-3445 HU210-2 FL10856.4 ESR-2549 CU - C-) M cn -2 HD212-2 FL17232.3 ESR-3445 HU212-2 F1.10856A ESR-2549 C) 0 HD216 FL17232,3 ESR-3445 HU216 FI-108515.5 ESR-2549 L- • 0 CL C March 20, 2018 HD216-3 FL17232.3 ESR-305 HU216-3 FL10858.1 ESR-2549 PRODUCT APPROVAL SPECIFICATION SHEET (2018) March 28, 2018 .0 U- H026 FL17232.2 ESR-3445 HU26 F1.101155.3 ESR-2549 C) CU 16+- HD28-2 FL17232.3 ESR-3445 HU20-2 FL10856.4 ESR-2549 As required by Florida Statute 553.842 and Florida Administrative Code 9B-72, please provide the information and approval numbers on the building components listed below if they will be utilized on the C) > Re: Wood Construction Connector Compliance for 20iS International Codes & 2017 Florida Codes construction project for which you are applying for a building permit. We recommend you contact your local product supplier should you not know the product approval number for any of the applicable listed -0 E ci) 0 HD410 FL17232.4 ESR-3445 HU410 FL10856.9 ESR-2549 products. L- L- -6-d Q. To Whom It May Concern: HD412 FL17232.4 ESR-3445 HU412 FL10856.9 ESR-2549 Category/Subcategory Manufacturer Product Description Approval Number(a) '.0 CU Test Pressures CU -4- Section 2303.5 of the 2015 International Building Code (IBC) and 2017 Florida Building Code (FI3C) specifies that HD610 FL17232.4 ESR-3445 HU810 FL10856.10 ESR-2549 U) < joist hangers shall be tested per ASTM D7147 Testing and Establishing Loads of Joist Hangers. Previous versions of HDO410 FL17241.7 ESR-3444 HUC0410 FL1 1468.11 SIM200804 1. EXTERIOR DOORS 01 the IBC and F9C required testing to comply with ASTM D1 761 Test Method for Mechanical Fasteners in Wood. Both A. SWINGING ThermaTru Firber-Classic and Smooth- -Star (NON -IMPACT) FL20481.1 +67,0/-87.0 psf 0 CO methods determine a connector's allowable load as the lowest of the following: HGA10 FL17699.1 Evaluation Report HGA10KT FL11470+4 SIM200803 ThermaTru Firber-Classic and Smooth -Sty (NON -IMPACT) FL20461.6 +07.0/-67.0 psf 1 Lowest ultimate at three tests (or average of 6) with a safety factor of 3 HGAM10 FL17699.1 Evaluation Report HGAM10KT FL1 1470.4 SIM200803 2 Average load at 1/8-inch deflection ThermaTru Firber-Classic and Smooth -Star (NON -IMPACT) FL20461.9 +67.0/-67.0 psf 3. Calculations per American Wood Council National Design Specification for Wood Construction (NDS) HHCP2 FL17236.7 ESR-3448 HCP2 FL10447.2 ESR-2551 The primary changes in ASTM D7147 are requirements to measure properties of the tested materials, such as steel HTA16 FL17680.4 Evaluation Report HETA18 FL1 1473.5 SIM200802 ThermaTru Firber-Classic and Smooth -Star (NON -IMPACT) FL20461.14 +67.0/-87.0 psf strength, fastener strength, and wood specific gravity. The tested ultimate loads must be adjusted when tested HTA20-18 FL1768D.4 Evaluation Report HETA20 FL11473.5 SIM200802 ThermaTru Classir-Craft and Benchmark FL15225.1 +67.0/-67.0 psf material properties exceed the specified properties. HTT16 FL17324.2 Evaluation Report HTTle FL1 1496.1 ES-0130 ThermsTru Smooth -Star and Benchmark FL15225.5 +87.0/-e7.0 psf ]CC Evaluation Services OCC-ES) revised AC13 Acceptance Criteria for Joist Hangers and Similar Devices in HTT45 FL17324.2 Evaluation Report HTT22 I'Ll 1495.1 ES-0130 ThermaTru FiberClassic, Smoothstar, ClassicCraft, Rustic FL7640.1 +67.0/-67.0 psf October 2016 to incorporate a methodology to evaluate products to the 2015 I -Codes, Simpson Strong -Tie is worldrig on re-evaluating wood construction connector loads to the now standard to update our product evaluation reports to HTW18 FL17244.8 ESR-3455 HTS16 FL10456.22 ESR-2613 the 2015 I -Coder. As soon as the updated evaluation reports are completed, we will apply for Florida Product Approvals. HTW20 FL17244.8 ESR-3455 HTS20 FL10456.23 ESR-2613 B. SLIDING MI Windows and Doors Series 420 FL15332.1 - FL15332.5 +40.0/-40-0 psf However, reevaluating a large number at products will take time. While manufacturers work with product certification HTVV24 FL17244.8 ESR-3455 HTS24 FL10456.24 ESR-2613 PGT Series 5570 FL251.10 agencies to update their wood connector evaluation reports, we recommend that building departments under the HTW30 FL17244.8 ESR-3455 HTS30 FL10456.28 ESR-2613 C. SECTIONAL Clopay Building Products Residential WridCods Doors WS (SX7) FL15279.37 +30.0/-32.0 psf 2015 I -Codes and 2017 Florida Codes continue to accept code reports showing compliance to the 2012 and 2014 editions, respectively, until July 2018. HTWM16 FU5223.2 Evaluation Report HTSM16 FL11473.11 SIM200802 Clopay Building Products Residential WndCode Doors W5 (16X7) FL15279.53 +30.0/-30.0 psf The information in this letter is valid until 6130f2018 when it will be re-evaluated by Simpson Strong -Tie. Please visit HTWM20 FL6223.2 Evaluation Report HTSM20 FL11473.11 SIM200802 Clopay Building Products Residential VAridCode Doors W6 (8X7) FL15279.85 +38.0/-42.0 psf www.stronatie.com for additional pertinent information. It you have questions or need further assistance regarding this matter, please contact the Simpson Strong -Tie Engineering Departrnent at 600.9W.5099. HUGT2 FL6223.3 Evaluation Report HGT2 FL10456,18 ESR-2613 Clopay Building Products Residential WndCode Doors VM (16X7) FILl 5279.102 +37.0/-41.0 psf Sincerely, HUGT3 FL6223.3 Evaluation Report HGT3 FL10456.19 ESR-2613 D. METAL LOUVERED DRS Curries Division of AADG, Inc 607,707,727,747,arid 847 Single & Pairs of Doors FL1 1537.1 N/A (see inst sht) SIMPSON STRONG -TIE COMPANY INC. HUS210-2 FL17232.6 ESR-3445 HUS210-2 FL10856-R4 ESR-2549 HUS212-2 FL17232.6 ESR-3445 HUS212-2 FL10858.11 ESR-2549 2. WINDOWS N Florida DeputrNeM of Business A Probslionnsi Re(pAWW Building Codas said Standards Product Approval Application Delia pop I 1AVJO1e Florlde Deparkrant of Business A Professional Regulation Buift Codes and Standards Product Approval Application Dow Pap I 1AW140 Floods Deprtrnlad of Business A Professional Regulation Building Codes and stonderds Product Approval Application DoWI Pawl AWIS FIOfKlB Building Codes and Standrds I Ragulatioll Product Approval Application Dold am1e 'C _ > 0 V � � O t._ O Q O 1` C �!1 ♦/1 V/ U t� y, ^1 �A1'��t W U O O 0 0 � � 0 1 ' O � � �— ♦ V Q � W (n 0 � -6-0 � O CU i CU 4— -F� I ce � v, �'�e ♦•• �nn1 _ ICU 0 O Q �- m S10 fOleLa[ Ore lilt altPaoit Gals mil lawn ttmiMam aglW 1MtoMCALM.s laadrWML Yridred am red aGA®la AREMN anon RMNan 2017 7hanM•TN OerPeneeo Risk Wrlpllt Lyndon F. BdaMe, P.E. Ryan J. King, P.E. iW1NN17 O7n2Gu17 1W1arJ017 12n2R01T Approved c.rgery: 6a.br Coen (4,a12s5-,74o PE,94og ro,9>Tara555 w)acdegem:awk, aE1dedaDOWAM01rIAN dewowb�wn•ularM. oe.adaa. knad"evokmgon Rsw*oma Core FMrtoa RepMlend Ardracl«p Lkwwaed FMMa PratNtlaul E W Am 9YIgCAetllesM Auaa�le[YM Aaoowedfo<Set 0" limn slat LmetmstmllM GaWtmai tsI00a AYIWmaQ Blom E� 1 a. ThanM•TN FbaCiseab and 8moo8b4r Naatnat a8W;6 agrrotltaMkrpsae0uok Op*gr 12312020 NO Vme No WA Conpoeb Edge FbargMM ekgb DOOf gam; X owdourawn) B glae awkm no art golEft no Mae !born t1tOlene[ Smmdm LMIdWlibdrd NOON& mosm NOI ®2ARDMO AMmnY mom RavMbn 2M7 TherrntTN CapaaYon RIdi vWiphl Lyndon F. Sweats, P.E. RyN A lung, P.E. 12H912017 12NL2017 12/211JM7 Papas FBC CeMeory:. E dalaDoop (419)2Bb1740 PE43409 (819) 767-0656 SubCd,OW. 8wrhae9 Blanton DoorAwrrasu kkwewbwgowmkft (:oegasnNe Manisa flratuedonRppl tome epos FbAme Rp Rue Ar emk o t Passed M a PnoMaatoml Engkaa eaed Sea Am" are Gme gm.Errr arts has Nadi mmmud < Gmtsm Aomrr.AUl YdMd" Ydi" Mtlralla EOGAWMW Anroen lose RWMW 2017 Themes -TN COMMON RJok VAplB Lyndon F. SdWft P.E Ryen J. mil, P.E. 1«+54017 07112=7 iomaw7 1YVR017 Approved c0am: �WDo= (418)2M-1740 PE•48W8 (919)797fi566 cor"Poe a5 EdaWDoorrt* na oonw vrbtogoowltsma CanperogMeno Anchledoar Rapattma am FbAme RepMWpd ArNNa p p Licensed rbrtoa ProMu*W Engkna godkAruere Aoom�gM Aso dANAR seem ➢Wed ova! E in HVHZ 201112>Q admmm Eamn B I. Therme-TN POerCiwb and Smoof o1w NaNne188Y�06protNonanpWSquot Opaque /2131rAW No Yen No WA Coreposke Edpe Fbaglsr Skits Doer gam; x oadpualWO FLOAM 4U Gael �r am gets 2MLboka gilts MOM YmIM finfea4e[ fattsm AodoM[AlerM 3mum" )NNW baww FWAwff W Alamo am Ramebn 2017 ourrm•T:E ww oor (N&WAOM419)n8.1 Lyndon F. Bd)oNdL P.E. Rya)767-Mtong, P.E. 12n972M7 12n9/20t7 12211J017 Pardkg FBC Approve Category: Ededor 0em µto) lr•1740 PE-0940p (819) 767-0586 SamaMe gym. C«.paorae YNhoe Evakretlar WpoAeoma can ComplsaoeI Bawd:SwingingOLION Report FbrUa A a] I Arched a ■ Licensed FIMWK Profasb)al EreMasr FLarr,a SM gnaw go arts OoLbel5e Gab to ME N= umdu led 211M IMMrLALM M ididi lL VmWmW AWadM lr&Aoom l N�sl leas Revision 2017 Thma-TN OOry«Na: RiCkW IM Lyndon F. SOnK PA. Ryan J. W4 P.E. 10HOQW7 07A2J2017 IOMWM17 12I+NI017 Approved s**V LSMrWDow Anrnh®w µ+inµlW 2r-1�. PEIMOn ro13)T87-0656 coerparw kklwtw a3nNaced RapoAtom a can FkWIM ItegMMred AodJMa «aLbemed Bald. Pro/meeloft Engineer AadtsCamaMr melee Anmedlzad tenet amM �M! faoeWamodraats In Kvw gmlrtmmi Blown Eo 9 L Thonm•TN FbwCMrie and 8 NankW 68/�;8 dgwCNor4Mga60uok Gkaed 12/31001) No YN No N/A ConVooas Edee"AagWe SkgM Door (MaMpfbatMNq; x oonrou ) aareM4M Sea Awkm no ate DOLBO" gee in bow rmkow room ArlarLLUe YMOdWML mwmm OateMed ®GAIMM AMMO Ira Ra4dna 2M7 Thanm-r.EdKWrpo Risk 2WI Lyndon,PE434 0Sa*adL PE RyeJ. m-e P.E. 17n9GM7 12n3GM7 12/211JM7 CMagay:I9daW Doan (419) 2861740 PE•43M09 (819) 767� �� �C APOr4vr IubCoranry:aMpkg Edanla Door,'- 1, namreab. CaarpBarae klathod: EvaMredN wpaeem■ Core FWW Regbtewd Ardeed or a LWeraW Am Prosresb)ral asommaLboom Bait Sala mookac arts are amLEMOM ale i � mdoda a Revlalen 2M7 TlremwTou Corporwon RkA Wright LpWon F. SohnrYdL P.E Ryan J. Do, P.E 1WiOMT 07n2OM7 10118R617 12M21J077 Approval Ca4wery� Elaerbr Door µ1oJ 298-774o PE•4s4a9 (819) 7e7-0656 d,oCaMgay albachgExkKWak"M ROWSar)Odr Adabruf>topConrealM. M a FO'Iwtoe RepYaned ArtArd a • Licensed Flodde OOnnl B Aaab.A� A�ilmllr Aeomnaka ! YeW ad& aril IONIC GWIWt.1a0li MONO ets 14 n. Theme -TN Fb«Clsb and BrraalMSlu NomkW B8i39;08grotlMMmpaet6quot Olwd 12/3t1J020 No Yes No WA Coorpeft Edge Farm Col SMple Door (Mawkigiadwwg; x caalpaeda0 8 i Salts asaY3m arts are 20LBMOR gale '� � l G00� :0 �" � ao0� ��o At�d !I� 7 F. P.E. J, Kip, P.E. 12113rJ017 12/13/N17 t2lJ!1JJ017 dig RISC Appn Catsgay: 6daW Deal N1%2aB-17/0 PE•43MOe ro19j 78T-06r SubC*Mea4: awkVft ENWWDOW ASOWdO a Florida RpMMsedArdNMa a a Lkwad FWIW sere PM%"W lEnOktsv list 1 a Tna ru -TN RraClrle atl & ootts r Sts1aLAmM1M Needed SIMS pgwtNaH quot Ope" 1201I2021 Conoosas Edge Fb qWw Stogie Door owsko OuMwkro; x Cordpunsnon) AMmnM.latlae aalmWtstLM emmi SLMWLItlIR No tiMei aelmeSt Yes No adlM ErMM WA seat 6 t 7lrmrrTN FBrer•CMMM and Snnatlr&a AWELAmmM fad Nomina!Corrow a Edam 6Mra;Non•Yrpa.aBgMt opaque 12/St12021 Careoab Edna Ftregfw 8wn Door gnwaryouvwxg; x Corgpuatlon) AOeeedhwLIM aemuluffim a In HVM A No emW atr Jew Ew1Q VM No WA list 8 k TMrma-TN FberCMeMc and amoM3tx AeaLAmortr PMteAardrM N ff*os pfadge bo%b SkVle D quot Olaed 12g1f1001 C wouirg a Edge SkVts Door gnwYglOuh.vkg; x ranllplaaaon) alum wkjm anomdhLYM kHwm RdW= No Yes 1MMei Grlr Besoan Earrm No WA g 14 n. lharM-TN FbpCMMb and SMOOM- ar 9MWLAeMeon �am W th "do" agratNon•M,paww"t OMMd 1931=1 Csrgesae Edge FbaryMr BegN Dog AMmaLidLgr 8aame0lrdid � No ItnW a� Yes No gddal � NSA Wr.gdma LeffiSrdlWe oweak rouepeft x oonapurawn) Florida DepaAnsnt of Business A Professional Rpuition Papa l a, Florida DepeNnent of Buairxa A Professional Regulation Pape t a l Building Codes and Standards tamla Building Codes and Sterbards uesbla ProductApprovol Application Mall Product Approval Application Dotal) Florida DepaMteM of Susklea6 A Professional Regulation Building Codes and Standards P.w t a, 1ayJols Florida Dspellfnent of Business A Professional Regulation Building Codas and Standards Pap.l d1 I50018 noil2mmm Product Approval Application Dehll Product Approval Application Doha Sol End& or art art gooLholm art SmCe snow at arts gets 2MLEMMM arts Moo Ywea IrmraMsaL famm aM NKAMMOM kdkk WML )bid#" ABhoa d EIGAo®el &Mond alas Bret ME" ibwbom Golan A akmL&U era xdwd at xdd" LioYW arLAMMM Ahmed Mda RWMMn 2017 Tbame-TN CtrpenN® Rick WbbM NWorWAconatstlCoI Ryan J. Keg, P.E. 12204017 0021=17 12/22/2017 Approved Revision 201T TbWRWTN Cooperation Rkk WApM NaBaulAcaeWabond Ryan J. Kh&P.E 1241002017 Oe IFAI7 12FD=17 Approved !3t>WA� Btlaif� convory: ExbAp Dom µle 2MI740 Mtnapanaa kWWts (819)7674M cabw)y: Ecderior Dope (410)Ue•1740 MampwmnkMaAe (a73)787.6II66 Sete ate Got Guts ode aaaaaL Gre Oaf atLhD�e sots $00de al,:11 'a' EnOaAarDwArerrews a�+MaaNl: BwinpYe EdabrOnarAwratrar rWaroraldoaa, law lawn BaraanoL zwoo SemW Aommldeeede YIIeOMLm EDCAMlat YlOdeed allmrW EIGdMmal Anmad Mon MOM lawn Sfrdrar Gram mmeeaLtstuM NaMdatWtst Ydldtet MaeWW EaGAogrmla Aasama! amr CoapnMM Msavew CoMbOm Mok or Wing Coro CNgaatN llswed: corrWon Mork orUWg eain Review 2017 Mvo. and Dose Eminence, We Roberta Lance Stswn lit LAldk PE 021130017 06 IWI? 00/16QM7 Iomaw17 Approved Review 2017 W Wkr001va and goon Brent Blasco LUIS I" Loma Sewn M. LYW PE 06113=7 06r1112017 Oa150017 IOMW2M7 Approved Catsgay: water Doe (717) PE-02514 (717)317.OW Calawry: swatter opens (717)3811w= PE4W14 (FM 317-UP W8r.sllnay: Sderg Edaior DoorArrMMe .0001 ta6Cewo Yy:YdkpEaMrb ar)bMes BDOaAseMrrr M npaAvd.om AmMtsam Answered Mtrlaffi Use ate! � how ➢Wed AID Asa@O for Aar rmm arm a leew ownplowee ab Ewbeuon ROW earn a ce.)parno.ered: MMadat Report Sma ant ermetardrr 9e000LEN lOa nmk IomAQ gmukkn i aMmm Eomn ant LUM EMSELDEMON ankm&twboNL2 le tsSla¢ A AMWA r FARNM Eratn Parton Registered Amhftd or a Uveroed RWM FbrW@ A - I Amhbd a a Lbraed FbAda 1 L &gUO40 rNo4CrdOONt and 8quote4flaMurk by 66 and SA OpagN and GMMd Fbw*u Dow vith 1213IR02I No Yen No WA 5 9. mu"Mca -s ar6quot aid apuoteenelmak by ore and W Opaque and GMMd Fbrgiw Door VM 12/311=1 No Yea No WA Prob selomi Engineer Pnbrbnat E"Snew Theme-TRAQU ; aedwI19PASWORN kMwilp and0uWAV ThermFTrubwAt adwthad Swam" krwkq and OWwbn gmdkAlMooM ADW&AWI GUM anwAntatsat Imo amid gvAUAmnsr AnrrLtxft aim dhLUM bMrl 219M ant AMomalmlatlmAM I HVHZ guwdLkllt Brehm Pregnant, ant tmomLgmgdlm googRalffAyAleam ISHWIM oni" " arWtr Efr11a! 3 �VE8420ALW8W INGUREINFORCED SERES420ALUIdINaASWREINFOROEDG(O 12131PMO No Yoe No WA 4 00=420AMMNJMSWRENFORCED SEpIE842DALUMOMWO EINFORCEDOX, 12/31=11 No Yen NO WA 146.3NSquotw9Bdguot XO, XX 9811auco 6quot Florida DeperUneM of Business A ProrW Regulation Pep. + a l Florida Deparknent of Business A Professional Regulation Florida Depa rtnei t of Business A Professional Regulation Pv 1 a, Florida Departnwd of Business A Professional Regulatim Pap + ef I Building Codes and Standards 1lsrmla Building Codes and Standards ,a Gee Building Codes and Standards 116018 Building Codes and Sfrldards iffiWie Product Approval Application Dohll Product Approval Application Datall Product Approval Application Datall Product Approval Application Dchg Etttl2ro i E E8153104M Amu ENrILm arts 2i t 2MLBMMM gist ELF Slade Wake at ore gets 29LBMMM Gets Sim MM Ydmr Modotsm Lift or 200M AMYrtALkm= mwwm m 21M gale Ydlddld Isolated DoLbeft Or S&Anmdd &=mud AN" Ants Mat lour umdu4oc l9RMor Good Yd W m gets gi fddad tetraW adLBKON 21k PIDC Anmla Assmad amid Coon Venda ReWda) 2017 lrMliaOnL cbm ftom Proares cwtwy fasem Aooedrl.Ledrd yddomm Manwapwkm Waarow Tom" Services NA, Gary now YMM" aub a fwLhEmm IM29 17 aeno1m17 Accused 12100=7 Mate Approved MOM Norm RavMtan 2017 MadmOz CMpay edtokg Producis ftnWW so" t,aaeKAUM MdommL Mark YWdw6atd Iatrlak TrWg savbme KA. oarymnew immmad 2000 1112WMT rIGM17 0G.aMmnit Ao 1245=7 Mate Approved Cn Review 2017 M Wndowe and Doss Cak,Wy:EkMbrDom NaCslagery: neNV Edenfa DWAmeorrdllme Conoften Wkmh ENkatOen Raped tm a WA« Flatot Re91 Arda Licensed FAdb ante emmm Luis Anew to Lama Steven M. UrIcK PE (717)9N-9300 PE42514 (TM 317-0454 .«an 0111130017 Oen V2017 01IRSWIT 10FIDG617 Approved R"Ww 2017 M Vi ndoas and Doan Cawomr. yOMla Dawn SabOweSaY Sadkg ScimitarDwAaas Carnpaeame Mewed: Ealuadon Regal tan • Fbrtot Rea' Arched or a Unarmed FbAOS Sreve s4iga LWe Robert LCoas Steven It Uftk PE (717)365-M PE462514 (I'M 317-UM bakigwounAcom vd. 0111130D17 0anU2017 06n641017 1 W1W2017 Approved FLSIEUBMpmkmb CaYDay: Edabr Dope subCaftW SaabrW DWWDwAaNnE1M CeapNarme abaad: CartlSeatlCo teaks LMlMp (513) 7704M Ins (5,3)5,96586 rmeembrAMadopey.can Bit CeMnory: EvMAp Done SWCabgW Endeared Ibdodor Door OoWaar)op ebsarodCwd6cedorn Mora«�L �q (513) 7704M bar. (03) 5196558 Loom � m amp CU PrdMsbni EnpYM« Probaaonsi Enplane AalaCAu1 hownibLum AMlala for kmd gWM AWklAtl AMrandbrUse Approved for twtd gadM Let EMOWgaMnnM SodMMZMlalmale in WOE avmmLk ag: arms torten ant EMONLERdOLM emamulnown ralkoL MkdWL a Isms¢ 9deMLt= sum m 2s art 1 SERIES 420 ALWNUMOD S a bLamnm EMAELR Ekft 2mmialubloReam SLYIEB420ALL&W MSMOKO 12I31/2Ma aMm.d jor Ur AYommttsLUr In l me Iowa ublift aQ &WAN Yee No awn PW WA Let 2 SERIES420 ALUUMM OW AsaLArrmd S Ete SERIES 420 ALUMINUM 800 OX. XO,xX 12131/2016 AnomOitsrUm Approved ILIOdIt No far LIM eMW Omkw N m Snider YN No am ERrMd NM 97 OST W649 PAN42F+51; MA, 94, 73. 75, 1600, 190, 76, 7OV. MIT. 4RSF, WW8 SM, VW. 46.42. ad, 40, �6 IM GDW. GS, ORSW ARM MW, Sloe Pan Orin. 25 W) 81ngbCar (up to 90• wide) 050212M W V4)00DEaH74; W6 flange Door No Van No +30 PSFht2 PSF 53 Oat W6.16 PAN,2F15S I & M, 73, 75. 1500. I90.4R8T, 4RSF, MIT, ORSF, 46.42, W 4M, 421L ME, GD53, GDW, GASS, GR65V. ARSE, ARSSV. EDW, ED888V Seat PM (mid. 25ge.) Dabb4w (Wr to 16V 050210020 Wde) VSHD000EWI74; War Garage Door No Yea NO +JO PSFAW P8F +4s3Magw0maquot NON• ERIFORCED seSquotwaquot O Florida Deper6rant of Business A Professional Regulation Building Codes and Standards Pnw I a 1 141014 Florida Department of Business A Professional Regulation Building Codas and SWWrds Pap t a I +aao,e Florida DepeMant of Business A Professional Regulation Building Codes and Standards POP 1 or 1 tavmte Florida Deporkrlarlt of Business A Professional Regulation Building Coda and Standards 111=14 Product Approval Application Defall Product Approval Application Dshg Product Approval Application Datall Product Approval Application Mho MASU24U 2111111 MIN MEWO RarMion 2017 MuNkaaa Ili ywdo*B and Dope cia ow.. Edow Dore suboidn y: BMMs- I Dow Awnawe OoarPlle)rme Moon* Evskaedorn Raw sore a law= 210M IWMMALImt YmWdMM earnBM)wr Lola Rebenb Lars leaven IL LkWA PE (717) 3r-3900 PE4 2514 p17) 317-n454 bW*Wlomiwd•awn Rmt glue YWWad Auks W ON79r1M7 OBn11J017 OdLEMmg Ort EaQArnW Anumd OSn6r�i7 10nOrJMT Mtge Approved Goa nag go" Review 2017 M Nhoom POT kd)ratisp CaMgaLc Edabr Dees sukc.rgay: Snag ExIodor DowAseaMMa ComperepMAnot CaNnptlon Mark ofLMag Boom glow MmdmKAM( ydwdm Mt DaanReaAr MWri4Dede 8000-CER MismFDame BCCO•VAL (941) 404100 (79M 3,5•M00 d�.eom Got Got Yatdad john1W 12rJOrJM7 11r18r1077 adLEMan art F W2Mmla aomod 12R62M7 awn Approved Iaa11ta7417 S o& b °°Samoa=2a RwWcn 2017 CURRESOMMMnaAAW.Ine Collor.SioryMda Door COMPSwry:F�da COMMIan Marked CeorPaeoao ILaanow Caabatbn lark a LMtlnp I ng" isioNK.i1rI0 ldmmmm Oedb Dave uL LLC Ted Do r,PE µ ve dodi 2844 (306) 8M4707 dmewtle0b@reNbbym m arts Lit RWJW n Moo &AMON 9Glaa®al 114100017 100=7 gets Aaa®ed 12A61201T am& Approved PLM74l4 Slat MM N EWN Rewidix 2017 mmwmkm MWNdwx and Doom C+tsaory s,nbC+Ygay: tWgts Hung CarePeMN Ilea)ed: Ceralaeden) teak aLWtap anwer 22" CMIMrilbm Yetdm" Ibent I10kga Aomemn Atchaecarnl Sbwn U. Wok PE p17)sK3900 IyoxdoWrras AseooNtlea (717)s77$IW DaMnpaQrread.Com am go MOM a*MIM 12rAM17 1W3aot7 RWJ!EM 20 ffieAMLmla AwAmd tour Vaddowd M — Fb da RagI AmW W or a Ucerwed PbAM dClllaa Btlilat PrebssbrW Engineer 9mdkAommma AMONSfor Use Approved par Lin bow atln graL AgemameG{ed Apgrldfor Um loseed grr AeaLAm mid AoW,,d IN Use AMmmtbLuM eMW GMIM ova! EM60LOOldow SaokmLLumdamb U, Aum A11001�gO� e.11M 2Wa.1M cam Blab m Grew Emram led! to SOD4570 garce Minoan boom wo soGMr Door 04/141J021 Is WAR YN AhWemmi sneer Yea Yoe bases WA rat I OUT, 707. 727, 747, NO B47 Single and Pak* of Dews EMOwglrmr L FIN, faced, and Layered aMgia and paka of 1213112MG hdbw meWwCre. emrl>i AMWLIM Yen Yes somio YN 2e WA mu 2 iss SN Emolaardmr Seromall 6204 FWVFWpe Frame IGW Skg1a Hug tomome a in WIM AWdammi No a&" Yen No Edmn +eWa0 5 SERIES 420ALUMINUM SOD REINFORCED SEAMS 420 AUMIIIM SOD REINFORCED UX 12/31=8 No Yen No WA UNdL� 1436qug966quot IS ♦^D' Florida Deparbrant of Business A Professional Regulation Papa 1 oft Florida Deporinpont of Business A Professional Regulation Pap. 1 a 1 O Building Codes and Standards laws Building Coda End Standards IRMIS Florida Deparkrrnt of Business A Professional Regulation Building Codes and Standards Pa / a pop laaole of Florida Dopertrnrrt Backless A Professional Regulation Building Codes and Standards Papa, a, taino,e Product Approval Application Dehll Product Approval Application Deng W c— Product Approval Application Datall Product Approval Application Delia v g g Sedt LM Voodoo, ltsMeMar erects[ SemW AmiNKAlkvm kdddm Md Gre ale atstsrla N lwad Ambmd d FOCAMmla ant hmmnd aide Sede Men Nacres mwwbomr aaaL9[ lettsm lMeattAU M M X M daik ore Gres NdlO W AMIM W grtEMOM arts FWA=mvW ammam ar. CU "orya4ag 290 lalaM RwAdw 2M7 agiombuzmkmawmamaLem6m ! Cbpry&"VpnaWiConeeny, Cmeegay: EdaW Dom SubCaMwryr SeaaorW Bonder Door AlWYON COWuNrw-, OwtobNM Mork or LWkg fOWLr 2090 bduKALMM 1aa1dEm MaiftebrMd InWlekTesagSWAM HA, Day Ph~ (513) 770410I too. (513) 5194M •Corr gW arts NdWdd alomW 11rJawl? 01110=1 adLemiag arts akRAnmla Moon 12MGWT Ann Approved as MM MOM RevMbn 2017 Wmomm adder, suaMgproducts oivapeny atsepy: Edsda Dons Subostswry: Sedbnel D,1-r DoorAswiN6 CoKipaeaceMoore* Coldamen Mark arLMINp FdlEw or 20= aObOL&Lkm Ydddmft Mor VAmtmkd ItMM TMkgserviwNA, GaryPknhbr (513) 770-0062 fec. (513) S1smes yam 20 gr NdWOd AdOW 11R/R017 MIWA17 2a 21t MAnmla AnoM I2IO=7 Aral Approved Revision 2017 Ht1adltillaWode Ito! IIVA ,,e andDoore CABOWmml S.InCer' y:FixerAW" SrdK:sYnay:F6tsd CaapsaWN radrod: Ced6atlon teak a LWtg EmaoLoswabooKALUM BtNtBMger AraAnan AncMYctsrel SMwn M. WAN PE (717)3wenlov85-33M YrvlmeorrorsAredatlen (7,7)9178454 � AraLAmaMn emadLomadim Stsdtardiledrats 120 2017 12O1r2M7 aaomoikae agamatllgWe ill= AWdL= (HAMU01S ensure arimW Approved adM Everts RerYlen 2017 B sat POT kduekiss SubCacameany rr,FbwSudoa warQdnnonMWrd Coagamoe Years Qd6naWn MaleorListing Dow Ruwk mmmmede SWO-CER INerflOade BCCO-VAL (gWkopg W (7ema1625ao d�.Com AraLAmmM EmOWamdOn fdMmWAWotlMate 12202077 12ft) Mi7 Agelae4Melee Aonottsr.Iie tsmAQ 20MLIM 1211d2017 ism Bohm Approved Orr [Conn O L Q Approved ft Use Approved forUr UW RIM AatravadforIes Ammovad to Uns saw a" 1 too PW Tbx 72 Iradded Glw 04AZWO No VN No +80f-00 t PWF5620 gape Heads "Poo VW Feed Window 0980IZ020 Yes Yes Yes WA Let rZAMiMbiVJbEbKALOM Eno boLono m m Sam tared¢ AMWamGm Bohm Email AaLt EMSELOOkLmosbRAUUM PrmlagelalaM Sealomgubd aao IaHwHZ a maim tiWmm Ere Q an Or We-09 PAN-VIft 73.75.54A, K 42.48.42B, 4M, 4R3T, SM. GOSS, GR68. AWLS, EM wed Pan (mid. 2590 Sft*Cw (up M 9V Wide) o5wrA2n VANDCOOEMI74; WB Gorge Door No Yes No r38 PSFPC Par tO2 102 vv616 PAN-2Fi53: 73, 75, 64A, 94.42.49, 428, 4N, MUST, GMT. OOPS. GR59, ARS8, ED68 SW Pon(mh ts 25 gar) DpaCar (97 to 167 On021MOW wJda) VY N)CCOEM74; WN Gasps Door No Yoe No •37 PSFF41 Per C ♦—f O Lem Florida DepgMark of Business A Professional Regulation Papa, a t Building Codes and Standards taaola /11 Product Approval Application Detall Florida Deperkr entRegulation Professionalwards P.9. t d, Florkta Departmond of Business A PiOtassi nal Regulation Pape let 1 CU g Codes a d Building Codes and Standards 1/armle Buildilg Codes and StrWards 1I6rJd1e BIIIa1:at M _ gnaw or go RIM 2OLbass go I 1 Product Approval Application Datall Product Approval Application Dana MOM YdodM RNisbn Mir an da nz TWm►nu Cownm CaYgow. Bandar Dons aotm AMerLAlemr VAIME ML Ride Wright Lyndon F.$OWAA P.E. Ryan J. Keg, P.E (419)2r•1740 PE434M (813) 7674 M mildim aOoWW PDCAMmW WSW? 1WISr2017 lora=17 Aardrd 12H2r2M7 arm Approved W E limb I1mt lawn RWA" 2017 aMM sting POT Ind ume, Caftow. vadows Know K gam AMOUL LYMM miudum Dean Read: IwlamWede 9=-CER MWnWade 8000-VAL gr4t)49MOO go 315-2r0 got arts mm mo lMlaad 12f2mi? 12CM17 gre.PMmss gmt 9GAoMmm1 ANCEM 12R5=7 Mate Approved E Slant M1t Naar R"Ww 2017 mmadkg M Ml VAdowe and Dom CmOorrr. Vandme PIILr SmtIW lBdUKkUe YdldmaMt DowdeMnwr ArmAw Ard*9dmW SIMea M. UAN, PE (117)3050W M*mmedurera AssodWon (717)317-8464 arts am Ydow aMMaW 0 AMR0fa 01MMI8 gtleffiNd act aGAMmw aMmod ire Va1MMd Ei 6i '1 errk)I E 6derbr ReportDo"Aowm a me CtapaeameE*how vakrtlenRepontma FWtoa RmgkWW Aedarf or a Lba)wd FWtoo Probesbrnl ErnpY)ser paMOnadpeaaJpats. gam Q wobCaYg.ry: BkgY Hong Caegaatrme kledrd: OsntllloMien) Mark a LMag cam CoWgaraa Maaad: Carutlm Mora «LWNp axn set AMOLAdrgMr 220maAWmomam Annailmlee AoeOa�gM lamas oubmmvmz ford BWrW ama Etmeln Z PL*ta I a. 6quaf6aCkv*S*wk. aquotw.eowkw&*wt, 6asl;846TWMg801800t Gtamed Fbooda 12131I2=1 No Yes Yes NM Q AmIMGar AMrevedforlet Anmndforat bYW Was gooLa ®r! Arrla,ri gat aporaved.ior es, nett grr W)a mM wt or8gmrtCWw@WA R RI+sagak M%WDos-(X)' - 'p«dXNatng ConlPnatlor J ratAL 7 8146600 (Loge Week' i [monanodio f IWmgr Wry, BkgW Hung VAdm 07Aoam kLk= SIIO Yes N.= BMW" Yea Yme Emma WA rat I HE US Flo and FMrgp Frain EmdmLONeddm 7302 ksuMked Omer anewe InHVHZ No AMWLt= Berm Yes No Emma +a51-06 a SHEET NO. PA 1.1 RxWo D9pa hLwr of Bohm & Pm1welwwl R9puNMon Bd&V Coda old B164elaMd6 fhodLwt App-W AppaaMa DAM halal IIMNd 11 fA moms AWN J201 ashoon Me m rna m.�Lu.L 9Nmr mMNMMeLAMWa ]MMAaMa MMAaMA A a J AMWM Awe Rnwom MIST nNMwl..npo. em omaw LAURLma.PN awana Usk PA 1a97m17 lmtaml7 10NOm17 tamas t7 APPOW VIAL R17)M um=wuwM ps4M4 ("7)$174w1 a4.Mswwawlere lwkoelw RIPwt9wa. F9wdd. a1PNNMMNArerla w. Letm.M FMMMt PMwldwwNaa uNdww 8 OwlAwwww /domino N AmmoLft a lbw own am bmmsawllrw ao mmium slim Maim arwamla Mann Mann 2 wM VMIWAkimomk%mn 1141M016 No Ym Vol iW Pbdda DpMMRw1t M &rlww AM PwofOaNbwla R9MdMNa1 poplars BWdiq Coda w1d sMtldwd6 „BIM. PladudAWWM AppM9allon Date an ]morAa Monads anMN NNL LMMMM momdum MmmiLrA Nano IrLanow ALGA Mow Rw1dn 2PI7 MTAMd amooma awAormaw LM.RLMN..PN Swan IL WIN PN 10404017 101160017 10a 17 UMaa6lT AwPOM DatotMi•vomon Q1 3naw P'64m4 (717)31744M 1aMOr»Pan Moor bdW40@MkU= Rwdwl a19Nw1Id AnAMa a. LhwMed Raw. Frew.N.a NwOkNN OMNmAMNMMw ANbmaLYw AmrsdaLaM laNNr Nona MINA insoLailm Laaw voom MMMmaMAMrMAIm IM Ma IAMOMmMa MMMYrr Los 2 sw Vor1, 'AkwwwMMwon 124140PI11 No Ym Vm MA Flora. Dooff"W of a Mltls 3 P4oft" RaaLAalgn pry.,., Bel" Cod" Nd tNNw4dNwda tawwd Re" Apprw d AppNoabll Dow allow 9Ma IeoMlr ma ao !glared a* Min MNnn hem[ aim N&AMmi AMMMA MmM Rwara 20T7 FWNMKNNIR DOWN m wmmmo=.Om MMMM)9 o900O-"L 1M 7 IVIW 7 1YIO = 7 AIPORMI QatawyrIkIPNI t MOV400 M awItiaw W dLM�1yM INM.MM. �elwM a.IMPaww abaft cooko0 o Lewes or U*4 6AMlMtlmaMm Ina! LraNMmanioNN HOUR I M� b 1 kedm fmAADwl wpMa'NmP Ak..lwmfiwu 00NMe1 TOO, TO Y.a Na ftddN DOPOWwr Of ftAh as & PpORalft M Rspblon pawl rl Bu11 q Codw w1d MMLMdrd6 Imam Prodod AppWd Appka ca Dow nAlnsn m Nano MM 16I Ned 9mm mrNmAiMMm Mw9MsaL ]w�iar Nto !=Anna .eMOM, notam� ms NN am IiPidla 2017 POfIdiddo D.IMPIN* m.atO.Ot Noon -are lOmdaad.NO0O-VAL immn 7 IVIVA17 t omy Appmof amewr.Vaw..o , (M1)M6O w p"""am aMea4uannMoguls &Uwhopobkoft.am omMPmmo rlawe C.MwIAu. NdMM a LaAMa !l1L�Lsalm aemLAMalOM WrtoLMM WrAaLIYe IrNrat AMMYM aN! bNawmrbn arMmaorMam olMMa mmaAma amMmw been 1 mrwtlwA6Dsmooll lima AkmdMwlmiem awaaml Tm Tm Y.t wA MrrL9mi F1mWsDspwMwm4ofBuWaw&ProgswmWR gk* Of1 hpla1 B1"* Coda wld 8M4tdwds MINIM. RodlntAW&W AppMNwon Die Bfi!12111:16 gob MLMN tr Ore Moo aoLmmN ar m rio w molarmL Over a bmLAAMlm ]mlwwaM swam and IWAn hM Mow MAIM 2M7 am- -1 sla"PosalK dY. PIMMIwo an R.wa.Lftim AND h.Nrw. PJL 0e0160017 ODOM0? 0w6m17 INnaaM7 AIPIww ad" .POMwas pOq M6aw PMIIMam" low pm}agAM1 QooMPa.t.oroe 9oodoMw Rwpat.aa. d pl..w.IL.IMItId AM,eMMaa. hared Paw. F,N.pwNeN NNaaw 8 MNMtAMIMNMMM ANMmAttloN AsmtfMJoa freer 21" am AmooLoid6mmuLumm blooLamodw Mod" ftN 1 CwolMa Lap Milo fwawoaIMPad.p 'mum Vol Ym NR M RaWa DOpwMwwnl of BLMNl6w i ProNs" Rllgawon &"V coda ww swwwd6 P4OdMlotAppmval AppNm*- Dde a MINIM m 1di n gmdW s 9wor bmklwiiows FwAdw 2w Ana NwlN.9oft Pl.dtl.. klk PIM Imo LM. Rn.M L OP.. or1NNr.Pwavam 009494W P544121 wecPes.MP also PMgMtwMwoIN o.IwPNwaroeM.e 9wMw6w Ropwtwm. d6AW Flaws PAjmMArdYpl or 0 horde row Pnll ONO Milan BMmRbdYm IMAM toolLowl I Oo.P- L4Pwdo exponn llV moo hplrl lawn xdhkm MBA Yir N O A �N mum JNw iotlmw. PJL 11a6No17 0MM1m17 a'aM7 Ima017 App nd Coll I, owl gooLAmrrw amemL LMm AnuwdbLm low now amemumm ouLowe MINIM MAda MDMMMMM bms 12614M Vol Y4t NR NR FIM DL1palM of BmMww A P/obs"I t R"Www WMV Cadss a l d BIwldNwda Pmdvd AW-d APPNOFA- D91e 5111111111 9ok Manta m ]Morn SEdENK amm amsAUe R.Ndm 7wT7 Alva IdMdI NoweM,Pwod.aR tot FYMamwa »w RmM1 L OPM OwltallU.Pwal mina 00•30aw7 1960A1Y1 a.MMrPNIMnro alkwltwROPa9.w. MadkewwN FYdwt AMpmwwlAoWdaa lhrwed FNdw. P.lA.dma 9AOdwr 6MM�belMt am 2 IlwaoPlWM Los" 1O.nwama MP awq wrpirl MINne OLr ar BOLb9mN as Nebo& MUdMnm Into ift 9wINMwd. PAL ma6aa17 /1I61017 COMMIT, tOMWT APPtwd MM t67ffi9 aN1aINMNwMN WedAMOw ANbmMNJY o!m a6r OnIrOOMNlsredOrt Wei add&= @OWN a m 72AIMw0 1M Ym NR NR PaMkM D6pwMRNr d BIrMIns M PwobaloLlaP Rdlau'MMw pry., rl 111111 1p coda and eMMwwdNMds uNm. PSMIMwd Appwara AppNNa a Date LMMMMNaMI go INIBLE m IIIIN111 bards moor wwmmLAL .w 19mimal mr w MM��pr A • Mrr. FbV MM m17 Ana MwMPaIYNAMPwN.w IR Rodo"nr rmwL OPaa JNr swNwld. PAL Og67A17 ONOmM7 o6ww17 IWM W7 Qdp144wd ON16ar-PWWVlrm am$411027 P600121 p6aYNAM20 o.�wprwa4w.aai.w.w.R.r.1amM. d*AM FMd0. ROWMNAM4kMata. thla.ed PMMt P.MdwNwd Naawwl 6 Aft Wmkga Ahem MOON lnM LlOOma aLWtiMMrMAOMe olma owmk a mom am 2 IIaalPawLgaY4 6lon4ow tupo wP /fo/gM0 VON YIN om NR FW tN DspwWw* of BwMww 6 PicftWwwl R6p 1 1141 &"* CMw ad Maww& PepMwt AppaovM Appftsftn D" F.P la l Rat D6p9wMnwr l f BuWww & P Ruud ReWAwwl 1� Codw ad BWwldud6 III Appr-d Appfto" DUN pop l rl ImmN FlorM1N a a� co" Rodlwt AppFW M AppMaMOn DAMP papiGgi RolMDpwawwM of awhnw M ProUaaMROdww BLraN,s coda Ala saelawa9 III App d AppMood- Done pop, r, 51111112 m MMMLU so as babe" a& OIMQMIi m MINA mo am areblmM as LMMM Lea MINA MIN Mat segm MOM edtfM11M1 9Na MINIM Yoe m ambom so no arlM mains 9MMr ■ ARW A: ]MdmdMM aLAAr,A A A MMAIMO NI hNMm owe an ]Mono mNiMea New ammL&AAmw DMI Aa ]mMmM bdaA aCA� AMMO Mat m Noon tors km Stew ammLLLMM aamdaL MMIbI Nonni ands AwMm mar m amM asMms amm M sELAkh A ]mILMIAo AANaA ft M WAMW AMMN Mar PaWdn 2017 AMU NMk Tbmwm Lp"F. fthwa PAL norm.. Poe. PA, 12014017 tOem? 1,0O1A017 171talm Appww &own SUIT AMOK N*TMEWM Lp.ww F. adow10. PA. ""avail Px 1004411017 IGUM7J17 1O1141617 tww12w7 Appowed Rwadm 3017 cm L-, Mid, FAbldNalaNp JonK KNorM9. FE ONa7l01117 O1apw17 002M7 12M20W Appwww 141011" 2017 TAMlOVANA PIMdo. InL Kawwm aw"Rpod Leftsood. tal=7 10NmMT loom"? Ivur 17 APPwted awagam "VAN wMatAamo P543M dn191704= O94W.Fwwlwlw (lfOJvx J P6 WI wM wJlan I'Mod" p0.7wONi Mama pN4)7fY�m24 a.h/wy: R.tee (4l1)a91lM. P674an1 CesQ 2o61an M.,Lye,/I,p SAM Mmmwmrma.mw aM+LYLrwr soft MNMmo.miwrN..Iww UtwwYMot lowt}wtwoptwko.mn o«wperwrMaM.e 9MtkMaw R.r.d Lorne o.ama.w.rl61e [M.ka4r.RlPow9aw. o.a�6wM.. el.rwe lMokM.ew. NlPtw Sow . FIIMIdt MidlanddAQfeor a hw*W FMd PI.wlwNaa LIAOIn r PlolaWaMwl NnOkM4tr FililNMtlN.Mta.ILlwwFMMid. pwhwama Wome IMIm1m isloww a.Lhwwed FMMww RMWNA Nnwl WmlLft AMMmAtla Wr a" gmdkAw AMmmLk" WMAMLWM W Mwln afYNdnsM INfNNiIMJYN AmasiMtJYN o.m Nola awrMM/nlffM I MMI&U w AMM MLkft omw anon aMu LaaaamomN atwwwWYowart MAea aowum Manor Lars arM LaasarrosM amMtaNMMMam M=ff aNrlamMa MLosA bran aa! LrasamiMM IMemLookwML w k= amm l aarmM bows aaN assoLmmammlhKzjknbLmtaLMMiaA smawLerYIMIm omMa ONIMLleMi aNMMA am t waprt2TO6MIt eon VMdw9ow NalNf 12414010 N. YIN NO NR Y R6WMaylawMm T46wok Neat iWerOWI.WWS tywl7Jm, No TWO a ww t OAPAoptNlRo4fawwOlw *4*l wed. 640im 1fIM01M19 N. Vol NA AIR 6 N sal. A.p1rRmmkl" M,mbta 01A1wme Vol Tw NR IIe1 Roww Dpaw1 of ou*wn • P1aNwbna Rpl"On B A ft Cadw a w aM1ww* PwodleotAppwova AppweWm Die WHIM102 m loin Aonolles Lear MobELLL&M Roollta 2017 LV. Temwm, ors doo Tbo"M* bon" Tmy addkw b ftwk mw moacon""CE4 m p"24"M Pa.74w1 OotMawp No" 1wMw0,wwYloeeM wMt 6NIErd9wp wLwa6M9 Aot000wdo aM w w Im6aPaRNarlYwaM, dyer. OwlpotwwrtNdds d.dwlta RtPa9wM. Frat Roarr.MdMma a.lewrwa FYIMP P.Me.arwa ■Moan B Meet bLaMwMrdLIM 7 7AkID0 PUT" aseft.1AawMNabaw7na 26P.wwdowtivwMiNwwM lee. halal ,Aam Boo ON &aim" ON mmadm lAdlmt so" gwLh r AMmm Maw Lo4mewam lame ? 10100017 WrIA017 12112M117 APPWW ONA MN.two araasrn WNaft" UMslataw M" ]MOM M mnMY:aNMMMam am moWMMa now" E m avmm9 V46 Twa IW Not Fbft Dspwonwr d BLI*wn & P7MswbwW R9MMaNmI B11aa1M cods. and s- " , PLodlmtAppwvW ApploodwL D" pya l a/l ,AImMt OYlOMBt m mom tmiiws Owarm w�MaLLLUM ]rlawML ]wmrnLA a1M��d � �A mom RIM!" MIT FMdm Mh4apr.mmku OMMMJmm AM=L wldw. PA.O wimnPl..wr, loom? loom? 1O11741117 12012ow APpwwd a wlaNlr. Awep 04710,4411) OR" dMPYowd, P.E. stsLytl6wP RWNPAm ossOrwatwm dukoh- P541M2 p911414.7107 wyQanarrRwMlpMPrm owlaMMw. rare Mv.Irra Reed 9.w. FWAs Ro111wd Awalma a a {hosed FM W MMrLAMms InmmMLMMM WrLoms lmm now Mae eraMaaNMNMen m ooLom dMMm alma awoalma son m Lm9m a- FLAMM aq..klRI lampWa4awk AM.6wn1 Rk4.YmreNPMW/wddlMrald 12%IAM Ned 11w NO WA Iwa0am'AkMawm F4DIMl6 D6pwNN9d M Bualron 6 P *bee* R6pdaloe Buf fit c0Ow wW BlwMdar I PLodMd ApprovM Applud- D" Paplrl lm mt furldi ! afts m aeon a oldi= an" MONELL ass )IIOmMN MMr n/ MMrd MOAM0 w A M d a" RKUM MIT No 1111 H I e lumbdow lb n unwm wwo usowm awkwa o y w. wd w I&MM 7 IOAwM7 IO21a0'17 PANWN Qa1eNP•fn9p pauses 6 MnNrLLO. OWN4- la eeowl6twyrftn" sw P "Evsk0fto& r fwwIMMM. N ammomniNmak mosum sr ammulam IM®maLPoL warm IMAM but assoLoidLomeNAMMdaMaaeabM O� Ism aaeamMA m ft M is arrw.mN PIS Plow -Falk 4a 10MIMMs No Tad an UP, immLaMM Fbwk19 D9pwal6a of BwMww 3 PlofwMwwl R9a4a1aon ww, r, BI/rl g coda and a wldMwde ,sans Rodod Appoval Aw atim Dde lioLK Da so RdL&o� so m ]wain MmikwmL sear adarAAAMM SAMO N good how" la9Awl111•r AM MIt was RWdm 30f7 LV. "MOM In doThowpo lAawwlwM AwyOww" hal"stRN1 LPtl1 BOOM t06=7 tO Mom 16117011117 tYla7o17 AOPw1 McWb Onpwy(TAMUM (044545an PE*W MOMI.7w0 Cwd9wFM fro op ilwi6wwYkserq.loMM SWXWNM ry,llo.eaAawwwwitdmwm dlaa P.Laer rbs" bow. alwPsmwtMne EwkaewltMPw1 MM. Ple"R.Ii Aeddwaa.lJMMMFrey poem ma r4ow aANtIALbINM armAMwww aM wmLwmm WNdaNn Amm OWN aru Lsas mmawoe 9rlsaaNMdMam omMa 9mrLm MMnar bM 2 TAMWOOO NWrVw. fat m,OM= No YN MR 4w4" FbddM D6paAILlwIt of Badness b ProisabwW RSIdaMon MVp t r, BWana Cads* neon StwkMwds 10113" ihodMd Appel" APPICWJ- DoaN lalk minx narMYet m soft Want a mr IrmruW swum ]M�r MA b� aMAMM AMO A Iwo Rwrre 2117 LOMMM ow ANdWOrM Jw sLW~.PA. WAwILU kPa 12Naa017 rA APPM QiNweRwN4 p01)Omae11 1115mi 2 MM3174M addesno7oN I SAmtwaweawm "Wbmom wmmw wwapedalrfwolyawdw condom rlwede EIwIWImR+aOwn ■ Freo RMpYNw Pj~oraUo maFIMd plaw"a ag000r amaimmomosm MtN11umM a meauLm WMMLMLMM !•want YMAM Lae ZMMMU19LRAINKffM=bnaMotanwrm amooLoo.m LI rota 9mmlma dram bMMs 1 QaduAk. DA4 law PMft WNPtoP"' Pd16k ROaVAN O111,011O19 me YIN No ,97AM97A MadmwlNrAllNw w Fywmd0m. Fim Dapawh - of Bu*ww & Prcfssft d R6MuWm pep l al DWdkV Coda old MMwylW* 111OdLwtApprw4d AppkaMNn Donal IRMw BAMBOOS 910 Milks Om NOW a LbNdm NOW an MINIM modgks aeAm mmsalamM aWm Mari Nan" MriANmew among Mar Rwesa 3w LV.Il%W W Mat des ilwwi m AnwdawN 40"CMpw4 tldwl ft Pea l.Wr loom 10RmM7 INIGN917 t011 M7 IYI2MPI'7 Appw.d Mdoomw"CL4m= 011,0246414111 PE-740t1 0"304n0 C01pr rr4om9 ionWgwMwoaYq.mw 6m0oWW, P4drq Aowwdmta w w ampNPaar Room ""mM dFIona 101tIYok wofAaM4Maa loR 9oamw ammmALftwim alikAmsew AMMOAM MM ANNENuk MM am MINIM MOM LrawareoeoM aoodANW Mown amid modk m anar bms s TAM0OO6RNwawawwo oNNw 16PLaedar.aewawblorwMkdor.rwWho oaMoa7Jon Y4. V46 Ned NA PbwMr Dpwblwwd of BmMwt & PMA Mawwl Rap AaNM Pow Ian &"V codes W4 a wldowms 1401109 PMdM ANMVa AWkWA L4 DMe aAmPMau now me*A� BNLEM� MOM m MliM MNNMYLNML aoNMNr i mmAlkm unailm ] aNAMMw hEMN awn RPdda MIN aoaRooe4lNIMYMLwM. 7MNwJmmw RApUdMNiwMldlm 6"w.Nyeo 191laDly IOAMM7 1921AnlT APplwd Qa.PlI AwmM plw2mame atwltlt LLM 01112644111111 1aMfhtowyr RaoeMyTNr ewmtjlMaa1a�01am OMr6erowraaMOelwroemRopedlala ■ PawNa Wkr6w.l.ILY goollAw aw a huam I6m otaLPMM warm son Mat bwmmmA aLm1M6aNmo6MMat MARK arrwlma anlrt bms n wNn IMiwapwlft.11 r 10*VA111 Id Vol NR MR avmkod b Flo DepwU wr a Bu*w** & Pmftukw1M R6MLAea1 p p Marl FmidlM Depo rkw4 of B1rMMw 6 Pwchisdala R6puoYoR now, rl BWdYq Coda old ew daft MIaON 0 ",-A C so ewM 011MMASId6 tlnal ProaeatAp MYM AppM9aMOn D" PMdMd AWwwd AXADsV N D9nM t�mPMMtA 9Aot MINIM MIN Mrt BNLbmm m fiADlaMti a& Alan Yol Moo m non am In Mims Moans on" a kuLau N rdaota ]maLw MmraA llummo AMmd wawa m )NNON a doom Mary ■mwwAAiMMa )iMleldaL 7PMnLMA AdmMA MMQA MmM AMEN Iwo Rwldwe Mtn NaNRoaRM/tdeMMrMLMMN. TA.arsJ.NwMoM IAAIOthom.eoww9m Qoyv WAW 1011O01117 10Aw717 locum" Appwla Roldw 3W sea R.dolebMNaIMIMt 1Mrwm JMNaed wwwoww9d.YMm any weft wr 101moiy 10011017 1 KIMT Applied we, Amon pop2etaar sPl.rrUA 0NMm4JNM aMrnnnRwallo pomn"Mm awPrmLLO. Om N"M sMeLyMM9t9, AQIMpTar fwwoojwnw16aboNw sMwywwP Rwee7am Mnajaamaabo.'m RaPafaw. .M fwdllaaM. w Il.dtaelwMMtewetep p4odMMdr,..IIMAw. L4rgr � aa! mawaNMrlMa a6dNw ao � a i bM a" laaMMMMoIMA a amalma for Mans 17 arrll9n-awdaarr.lmllw EMlR waMR oak PARaft -M,amk CA 1O04=8 NO YAP NR Na 16 0WM2M1-omay8rd. Mrlr&EW 00 Fat Prdb-NwadlNWMl IaWMI orb Tm NOR IW bMoreoNalTwww Aiwa*& FbwkM D6 WWW of B WkWft M PwdawMNwl WPMplwwl mdm1M Coda wd BOandr'ds P4odMd Applold Applood- Dote pryrlrl loom afiUMUMM gob MINIM am Not m ]MNIn amino= anew aaMrALMMw ]Prima" riWLA mood 91¢A1ed ALmnd MMNN Roadm 2617 LV. TIMmwwM, IMt m.Tlrwpw AQanwwa T.w oommM AowMyRP" Lear Now" 1O14302117 M900,17 10117ao17 *IiIJ017 Appr1.. WNNOMWW(TAMCM (11146411-s" M74M7 (1143e.100 OtdanP Reap beyawnoY.mnwpgwM 6NMOaoNwys R.tea A4wNwdat e4i w tw kI16w1 M MM Mast, aFdaaM ceniammNMo snowwwwnowUa0 Fred RtPlwtudANAlwaa.lJewlred FWM. Pr.dW0laaaa.w araLAMmMt WrAataM /MmmaLWt am goo aaE EMadamlmn a Om BLOOM mamlma emMow born 4 TAw0ftvud TM,OR'fwI►Vidwm N.MP6wI% 20atr.wo.Nw,wrll.r r befit O9M9aNM V44 Ta Mok IW Fb DspwVmd of Bu* w M Proba)m1M R6Mdwoi Bw*ft Coda wld sholdawlb ProaMa ApP-vd APPNNd= Doal halo+ I ,AYewl. r M ImJMI BM ] do tr.aLrwL mew M vlamN )bloom ]M �M A w AMOw MINE 111011" MY NORw1@11koaAYM. TIwm.Awwed RFMOLwI-- MOON oww.waaNr unawy 1ena017 102WMT Akvmd oa.PMy Amin, (an 28111 6 4KOWN LLCL 0003644111111 adW+aMywP 0 1 07M ewaa.NamPtl�taam wv.a�id otmlMM.�6Rq°'trow. Mu 9ldMLAwMsew AENW&kMn ANNNIUM W IMAM Am alma a� MAMA b6Mn m mom IwedkwIPIMP-L.ItawwrklL low=@ ND Vet NOR Mel amL kaI awnsm m gift m mbdm Isola 2017 mom ooeM/MwdlMLI eaYD.rPMycMe1M0T6m ampaorand we MW.wdM fad Iwt. hMMdMMo Evskwewmdy aAmmmumogm AKA I6 Nmmy/n-Oa- ywak6l.M.nr•SOMON Ara FWW DopMRlant of Busilsw 3 P/aNwlwMA RspdNMm1 BIAS " coda old Spndrrds P6odlee! AMovd AppoaMoll Dde pop fail tgkww gum Mm�oerAMl anm m Iddu arm � &Eno wawa 7k0aMed Jmnw9 IAPLDUMonbdmw awyw.wmww Imam? l0Man17 tamum 1100, d O0'OAl9a?a1 mentor LLO. omm$*M �m w gooLa MM AMwwliaat ammockno warm met bwslsmMM arara.r,MMar MARK aaaaleMa arrm ENms Pr1Pne.-I.IwYYN..,R loolwl9 N. Its SIR MR N 0 cn N N Q C O .( cu -p N N U O c C 0 O Ca U_ O .cn -� 0 W O s ca '�^ C/) cu O M cu O (3) u) cu 0 CL CU CL C/) -6--o < L V V `M� W W Q Z Z Q J a_ SHEET NO. PA 1,2. Florida Dspariniend of &=*a & Prof•noW Reguaton Pap f of 1 Building Coles and Standards +Maws Product Approval Application Detail Florida Depwbywvt of Business & Prod Regulation Buikirg Coda snd Standards Product Approval Application DoWI Pace 1 a i Florida DepaRnrnt of Butner & Pmf mwwW Regulation Pep I a l 111=8 Building Coda and Standards items Product Approval Appllf-don Detail Bpi gut Wti9la gut 20 21kJ9W■ 911e !lam gem goats gut 21k grtemmt gilt Bed 92& almdLa 2di gut WkeMdm gut lumnom 2M MUM xemma N m hat= solo IkokuLLU vat )1aa01 o me VAY Armand BQAmmW AMO M9 Arend nut )mt. n MMudw 2200 PadmKAlJdmu )hpddill HIM" Ambme EWiAomd ARNE d t■Ya mute Anon Emmk ill■ aging Co1111r a1L1■1a gm dadlet xdm" a mbme lwLamm.l A■SE d hire but vw b. um dodo[ Review 20/7 B"" Roo" l ManAYN" Thm"s JoMra WMO Union Ev*kNibn oeryW. v"trr 10NAMIT tomato? 10212M7 Approved Revision 2017 Over Prolsram produda, U.C. Tim Robhron Wal TI M Jr., P.E. Jahn W. KnacrvkA, PE Os0812017 0&312M7 M1t12M7 1212M017 Approved Revision 2017 olow Probdrn ProGrd&, LLC. Tor RabMeon WAIW A TM Jr., P.E. JOIn W. Knstavick, PE oW082017 oBM12M7 oW112M7 17022017 Approved Ro-Wor 2017 AlAmorkn & U2 M slid 4imn Consider. R- - I X4 2M)-Z 8 $"visa LLC. (208) ""IGO Compeer. owsm (71e� 0 0-75 0 PE-44107 (954) 772-0721 ceeeeelY: (964) 1•WeOefY: mumn pmbhreesey: Roofing Tim ftnoL ov WASbaM.m eebcre"y: dam Pander lid. eY9Calbsidey: 8. Pad dn.ro6Meammpppenemm subCabday: etolm Paned CeepanM. dotlred: Erakrtlm Report hen a m caeyYamee Wtivad: Evaluation Report from a . CoeyOoree War* Ewoitlon Regal from a Cmpd"rOe MW"d: Evelatlon Report fran s P, Evousbart Edifi, Fbrlda RasiiMeied ArdthoJ or a Lkwteed Flaiea FlorMs Ro$rWW AmhW or a Licensed F1olkf Florida RoV"W Ardaer3 or a Licensed Fkei" Produces ProbablmW Efl91 r Pnebnbcel EnOW Praftak nW Ell~ Junamr dfLthe adm'.WjWImt coma grit BC mt aMl Jm W f In Hem WON.= ANAMS emIMM g■eLAW homughLum AmmidbLum food 2mm 9r11LA1mor ammmdJaJM AtmrdlarWt loud gel■ 20 8arory900- Olivetti &Mnp;Oft FM Proms-LWAV,CA t010VMs No Y" NM WA All Bubm lRdul6 Ami S m.IlAi OWWALIQ RMkud e� aukElkin 1 20 GW gloomiest SW Storm Pocei Corrugated Overrated a "sbrm Pear removal 12A12019 Y" Yee Ya WA 2 24 Gape OeMnred SMW $Wm Pa mMMVHi CMWW Galvanized Ras" mom Port maned 121J12MB No Ya Yes Kim / 2299 damp; 24p GarmWe ore" Storm pervab or nd by treks b pno'/Me hurrkw* PMWdm. or flat by batlM to provMo hunr"va probation. moNLOOM Malaita am mm Vwd- rrrwme Review 2017 rrW owm" cmyaw" Gray MG CatesioeI, abuse" Componw m eabca4ee"Y: Taw Pbla coayee+r'e WOvad Evaluation Report from a Prodrd evokOW Endir FLOI� Fredonia aMa 1 r1wECOMI$krsHWWMemo (NAssix6) Florida DepeMient of Business & Professional Reot"m Poe 1 a I Building g Cade and Standards laws Product Approval Application Detail PLE"01 At gadW mdarcaudMr vdlWret )faWdkrm alfd EWLMMeat hmmmnd Mom mme )mom 11101111d MI Sbvert Lws ICC evakvatlan service, LLC VMN aL MWL PE ORMOM17 OW7MM7 0011211120117 Approved Revision 2017 rrw slowing Carpprres Dray Ina. (1117) 9188473 (407) 681-1917 Calnsipry: Structural COmpornn sevoillikefignewcom vateco gory: Trw PIMA CaeyeOavaa M*A& EvaNWlon Report Dom a Pmdud evailMbn Ell* lil1M� � 910GAIY■et AYommlfLUM Adm udhLvu laws 21Wt in mum gemdi9fmQ dmmkr e9mms! atal W W Com wdw Rio 12/312M2 Y" Ya WA Ni 2 ff W 111MAWA Rasp Pisa Florida Departinent of Business & Pm%$Wonal Regulation Building Code and Standards Product Approval Applleatlon Detail pep7di II Items EeMLa an an 2MLEMdM 21e gedW lkdtrLAJlmom vldddnml ritddW AMMON fACAMM1t Ae®md Mom Stuart to" MC Evanson am", LLC WNW AL MWL PE 09N92o17 OW0r2M7 WI2i2M7 Approved (847) glwn (407) 681-1917 Wwseelp, Isom 20dk A1md■m ammmlacm ANMMUWgr fumt ➢Wu PmbtWadma9e Sat InH" 20dk= Ifd■d emWm mom Comment Peas IV312M2 Yes Yee WA WA Florida Department of Bummer & PmfenwW Regulation Budding Codes and Standards Product Approval Application Detail PL*HMN t go 2NLboft 20 Min mm mB amwkdert gmkd mamaaLmsM )mlklldiml xud�ddm awn" emgaasom AMEMM awn Rov%bn MY ITW Bridle OMVO "Group In. $had Lew% ICC Evakmdon Serew, LLC Warm M. RanWL PE ONISM17 09107/211117 O9Gi/!M7 Approved camew. ahwbww cages-n (647) 9184473 (407) OM-1M7 9voCab "y: The PMef "e"edNpeneew.oem Comply nos Weed Evaluation Report from a prodxd E.Wn§M Eedy 6P� lYlmmuKHE am1eNJ meld gilt Mad Wastes EmaML20now In grtWtmP BONN ers■n 3 rrW W"Atko Trdnx mom Cmacbr Pim 121312022 Ya Yes NIA WA Florida Departnent of Bummer & Professional Regulatim Building Coda and Stwxlm* Product Approval Application Detail Edmta gum EnkdailmeeM ri9mYimG Mgr Nrolem Fro* L BorMaido, P.E Toy MOM, PE (561) 7124 M PE404NO (064) 947-0WN Moan P.p+pri laws 2111 Wk grLeed u grit Yaldlmd IIWmYW EKANU W Mood Mod 1020=7 R~ 91m®LaW 61RUMLftmt ArmMLbLum low two S'deWdatmltmHgda 16Jmli 41lWt.IlaQ auk" b+ 22p ANW. 24p GWaNsed ae" &mn Fors% 112012Ms No Yes Yes NA Florida DepsRmerd of Business & Proksaonal Regulation Palatal Building Codes and Standards laws Product Approval Application Detil RAISMM gm ifdar Wk Wk 2ILhot gut Ave ximmo rleafliNK gMkd mmmrLaJmtmt )■0lfrml vmddd lvkmmm eagemMA a®md Aktd Rav%sn W17 rrw Baldry CaeporWib glrpnlp kea Skald Lew% ICC EVMYaon$enleo, LLC WOW M.MWL PE Usti 017 ONOT D17 092IMIT Approved Camsiar sMwaM Components (647)9184473 "Meet-1917 StmCobpq: Truce PWa Wleeomokwkw.A CompgW Mal hodEvWetlonRapoafroms Product enkOM Efft HlJ WWL ammMJ'a9m AMmmuKim! Idmd grit and ages bmaddm hlmli gHwiLlmlt mulct presents 4 Rise BCOtaigra was mew Coenaw Pero 112131111411102 Yes Yes Nm WA aldmtiidilmt Fluids Department of Buenas & Pm%nWW Regulation Bu k&V Codes and Standards Product Approval Application Detail Pep 1 of I 115201e Flonlds Depwbr*M of Busi Gen & Pro%smolel RegulWion Bu ili ft Coda and Standards Product Approval Appilcafion D*WI Pese f ect 1aso+s FlorideDepartment of Suskwn & Professional RegListlon Building Codes and Standards Product Approval Application D@MN Paps i a / +saws Florida Department of Bltwwo & Profamo W Regulation Building Codes and Sfendarde Product Approval Application Detail Pep i a+ 11520,18 PLMKAN gadk ANN" Wm Wilt glkb odm gut guts lmid[ gee gale 00*Pwrr gut lLMktffim gm lolmLa 2a 20 2wiNd a 20 alninJM loot liomts[ gee 21b RoKb m gate Min vltm arrweer g1rW Pad mmAINM xd 9mgk ydim AMMON FOCADMVM A■ Nat arms iet votn aaeraaet gRwm LdmrisimtrI lmmmu h. lwmM lWmmWA MCdees9W Ao um Arm not vommB amdMlk■ good ladrt[AL1r I lurid* el WON AMMON PBCAOWAml ammm aura mt version Wmdtrt[ 2209 lkdl■cAJJmsr kdiltdax Mdi and Alikka and 17gaMmml AB1mmd am& Rsv%w W17 MITI Industries, Mo. Dev%VVM ICC Ev"uMbn serves, LLC ICC Baked m $"vbe, tons=7 7aIWM17 f 0/J2/J017 Approved Revie%m 2017 WTok In' ' , In. Dad VIM ICC Ev"rtiorn toot, LLC ICC E"koW service, fellow? 7afi9m7 1p221J017 App vod revision 2017 Mrrok M ftWI , Ma DWM woo ICC Evaluation service, LLC ICC evaluation Servlae, lQflo=17 I(VIS 017 10222017 Approved Revlon 2017 Wrok rdwla, Mc. owed WM MCC EvpMpnan Sorvloe, LLC ICC Evaluation Servo, 1011W2017 10/192077 10r=17 Approved CAOWr. ONWAVM CotrywWl% (3i4)Wi-7480 LLC. Copper. exime "comyoarrb (314)WI-7400 LLC. comfiliel Compounds Tea (314) Ni-7480 U.C.heesierr: 8trumdw ComponMb q 1-7 LLC. $ibCWpryI True PM" dwai4�rraam Pool, 699N800 arbareey: Truce PAN dvaidas va.cem rat" 599aw SubCWAM: Phil dwwlpnaomn (205) 690.9e00 e+*Cerpoy: Taw P%1" ewaLmneemm (206) 6B9.98W tlaeyarra mearoe evokmw Raw from ■ t aoydere MWu* EvaMedonn Revd from • leaPBenee McMad [wWUMbrr tom• co.ya.rw. word nvakrmn Rapat stem • ProdiM EVMu"bie EiMy Product EV-koom Eay Pmdrot Evaluation Emily Product Evok~ Easy gldimr.66mooe AsERULiLM Ammmi Wr Imo at guars Aum dhLvm aemmdJm[Ifl a" Risks SweLatmoor atm uKil t AMmmdbLum bow 2k t 91dadLMmnOm AMmoftJYO atlkadJMJmt how 20 t Wl 2almdAaddY�t fJma Getrlma 8ttl■r Poison Ma! a lmrtWJlWmdMgllt in NM oumma in ANON Pmwn A" ProdkoMadeLNmbwwNmemariWMmlt InHM aid" HIM homer Passing,Mal hmAi memo passing, 1 M768Re 19 pL super Mph fines Miss mnrleal4t Ph" 01ANZM3 Yes Ya WA WA 2 Mat 18 Is go. mla mMrda pbb MA712M3 Yes Y" WA WA 3 Mrfelm 16p. Mobetreryel uma rAftrpmb wA112M3 Yoe YN WA WA 4 Mr20 20 sis. MMs mmedw pisle 01N1/2M3 Yes Yes WA WA armdSma LWal�rl AM LSia M1m6Srmft Florida Depsrtirdnt of Buenas & Profeaialel Regulation Budding Codes and Standards Product Approval Application Detail Page i a i laws Florida Deperbreord of Busine" & Professional Regulation Building Codes and Standards Product Approval Application Detail Pape f a I +tabu Flodis Department of &mrwn & Profas a Regukdon Building Codas and Standards Product Approval Application D4ahil Pape let I ifeaole 6filliffm 220 mom 21k grit 2INLEMdrd grit We EBLW W 20 21k. gdtPedt WIt Jill 2m aotiec9t am Oak 2MLEMOM Wk ! gar Min xtolm amtitml gaol andouLa m m mdoom mil riaddm AMMON! ENCAMMO ammma are. mmd vnma reams somm JkomreiJJmmt )migilu mL mt AMMON I = Assumed AMmmd Mrs MUM riot nwkbo LMn 2009 lfddrLilmt 1 rigdo mt idd" imb9m ErLa dm ed Ammad AMR me vwom elmda k= Rev%%n 2017 karek mawW, Mo. DwM WM ICC evaluation Sane, LLC M EvabW M Serv%s, lomwiDI7 1OM 2017 1017AM17 Approved Revision 20`17 YVwyMroelrs" nob s.etwin ICC Evokadon S"ew LLC Jame A Rod - asi , P.E 00222017 OW1111 17 0711113120117 Approved RWMM 2017 Nryamarr" Rob BOMab ICC &soutd on server, LLC Jew A Rosen, PE. 08222017 011112w 17 07109/m17 Approved RWANon 2017 NMyadrauw icee•8, ekuaeM cmyo"Ib (314) $51-7400 I.I.C. Co spow. &redrw" comporWn (253) 92445470 MM OO.1344 aK-13M Catesi"y: tuOCoba"y: Taw PbW (20 dwer�rnLam 6) 504M OubCa%Wr. EnpMeered Lumber ree Lumber SubCWeO"y: FunpkwLumber RgOMgeMahnmwoyprir Lumber caaepOoaalleOvad Eabrtlal PAW a CoeyMedmed Evokobw Report glom a Complains OUW.mm CelopOerw ErM"tlm $ors • Ceaeearlea Wtlmod Evakbtlorm Repo from a Prodrd evakoeWn Eedy Product EvshWo Endly ProdW ENKWN Ell* 13W lam" e4MWm Entlpf BtllII$lIDdrk PL82tirm PredatespJ and kAWmee b W Watt Jao9La M Am m2abLlm$ as mmLka o OW 211m gmdkh m AmMrkUKYM &WnUdAKJIU lima Rift eau AL EmMoUNuddm do InNNM 41Mfe = Boom Pm Lea EmgwAWrddlm aekltlMWtI InNVIE gem&= Sam" Pmwn a■! em lecas6genera gulmWE>tm�Wk In HVHZ gukvLk Ai aemkr programsaMl 5 NT20le 20 Ms. 100 WensiM Muss 6roeruckr pbb MAfrJM3 Yes Yes WA WA 1 Mbml mLVL Lerr*vabd Vervesr Lumber M912M9 No Yes WA WA 2 Postern Pal Para1N ftow Mmtw =I wo No Yes WA NIA 3 TMWermrmw I& elA■iL11 Woo nit xuWM arrnrarame PA Men 2017 Wayednaorrr CakeOee3, 84u*NW Cde1mPa+tera .U401 , , Lumber thnmaprrw darted Evaluation Repo Ban a Pioliid EWANWM En* aMa 4 TJ Poo eserd Florida DepsrtrneM of Business A, ProfaaiorW Regulation or of ood pap 1 a i Florida DepaMlent of Business & ft%*Wonal Regulation Pap i a+ Florida Department of Business & Professional Regulation Pap I of Bucking Codes and Standards ramie Bufi ft Codes and Star i:Mwds +"awe Building Codes and Standards Product Approval Application Detail Product Approval Appkntkm DafNl Product Approval Application Detail addLa Wk Wet 2m.e129M Wk gamlT4m gut Elms[ go gut 2MLENd u Wk 9991 ErsdxsL Wits 21U Dee Pandm gd1 gtmd EodmMlJmmM vrWNm[ Y1n1kd Am ZWLAOMtm Atoms Oda mu rite owNbom[ gtmfd asamuarlJlrer rifdlklmt 3NEW Aubmad eaaAmmml hmemo am& I191 version Mamdaclln[ S endrvaerAueervae vMleatedev YWIdMedSubeliffild FBCAmroval Anse$ Ant$ Rob. ICC Evakmkn Servlw LLC Jam" A Rclhmn, P.E. odrA=l7 Oe/J04017 07ALT2017 Approved R"WN 2017 wwod u"r Rob Model IM Evskedi n esev%s, LLC James A. Reason, PE. 06422M7 0920=7 07/03I2017 Approved Revision 2017 Gulf Coast Supply & Mmufadurtng, LLC. Eng David Daniel S. Kuhn Looks Bowden P.E. I OM 22017 10tiO/2017 10/172017 12/122017 Approved ( 111"?a (MMOW1344 Ada d 0, 1: abuse" CmyorWn atrstella ooY: ErnpMaMd Lumber (M024-0470 OWSWI344 Category: Roofing subcategory: Metal Roofinglua (352) 498-0778 PE-75519 (334) 3041800 Inloogulfcaa"supp y.com eaendarn iceaylflnpe Wtlnod Eakrdbn Repedfrom a "vasrcan Corrpllarrc. Mahod: Evaluation Ripon from a PMW EvakWbn Eedy Florida Registered Architect or a Licensed Florida Praessim" Engineer MdMLd111■■d A,,mud*,U- ABENMU JM mtW Walt 9reLdMoto asmmuffAn aladmdm[Imt mom Watt gmimagabonaw In NM 2MMAtk L make 1'�ern tare kmAL g1mi6im Bad" Pole Quark. Assrraso s Aoprovad for Use Amr-cl for Un Impact Dodge StruekeM Cmyab Lunlba or Oriented dbend 111=1I2019 No Yes WA NSA s wwiadwKmw arm Bard 0done d Strand Born Rim Bard 031312M9 No Ya WA WA Ant Product Mode. Number a Name PredigtDescription Contract Expiration Data In HvKZ Diastole HVHZ gyddeul p board Ri" Beard 1 0.032&qud; Aluminum 5V Crimp Mn 0.032&qud: 5 V Crimp Aluminum Roof Panel 04/12/2024 No Yea NIA -NIA! ever 15/32&qud; Plywood -108.5PSF 2 0.032&quct; Aluminum Gulf Lok ern 0.032&qud; Aluminum Gum Lok l Uqud; Wide 04/11=24 Roof Panes over 15/32&qud; Plywood No Yes N/A +N/Al -116.OPSF 3 1&qud; 24ga. Gum Snap 1&qua; Gulf Snap 24 Ga. 17&qud; wide Rod Panel 04172(2024 over 15/32&qud; Plywood Yes Yes N/A +N/AA-131.0PS 4 1 &qud; 24p. V-Loe 1&qud; VevsaLa 24ga 16.5&qud; Wide Rod Panel 04/11=024 omr 15/32&qud; Plywood Yes Yes N/A +N/Al -138.5PSF 5 %qud; VasaLoc .032&qud; Aluminum 1&qud; Vaasloo min .032&qud; Aluminum over 04/12/2024 Yes Yes N/A +N/Al 15/328,qud; Plywood -101.OPSF 6 1.5&qud; 24ga. Gum Snap 1:5&qud; Gum Snap 24p. 16&quol; Wide Roof 04112a024 Yes Vas N/A +N/A/ Pen" ever 15/32&Wrcl; Plywood -116.OPSF 7 1.5&qud; 24ga. VersaLoc 1.5&qud; Vere.Loc min 249a. 16&qud; wide Roof 04/122024 Yes Yes N/A +N/Al Panel ever IM2&qud; Plywood -123.5PSF 8 2&qud; 2490. Megal-oe ern 24 Ga. 2&qud; MagaLm 18&Wot; wide Roof 04/122024 P 15132& P No Yea N/A +N/Al 1085PSF Florida Deparmllsnt of Business & Profeseionmll R"Lidw Pegs i a t Buddng Codes and Standards laws Product Approval Application Detail ISaI■Jtta WM Dam Wilt Wb 2*2m M Pup Min rite keainMe gmkd CoesdaaLemt xrWdlQbC )Me AMMON FMA- al aM M nit me bb 2017 cw-cv mUSA Ma Got pal Rondonia 91000-CER AmerstiosesleCCO-VAL 11/1420f7 10I1p2017 11212017 Approved calsorr. sabl%l CmydeWn (813)0214641 (78%315.2590 eubcobeeoy. Product Introduced n a Ramp of am Now TO&MObW Ceoyaerne MWwe. CwWmdm Mod oruaaq PLAME14no leaned. AMENOUK.Yr Arm suwjim mud gWt Aeaa EmaoLoda EMANUNN&ft inmom gwdaj a ftokm ersr+n 1 High MMO Coaaam Lion% 4, B, 8, and 12 vim *00 demob wm irAls Yes Ya WA WA lookafto 114.111,17744112 2a Paola get An WkEMMM ab MUM )Noma mmmmrmm Gomm EWeeciJlmoe )mmdmJm 3MEW armor eaged®,,M AM M" M Roewh 2M7 Commercial Conroe Produob,Me. Robert Gar imm H. HUYNH Jahn Hoy 101142017 101132017 iWASM? 12/1212/117 App Consider. Bowed Companies (613) 869- M PE-0M22 (352) 5e&6311 SubCsOwt. PnldKts seesawed a a Revue of Pnen%PVM yWum ache Now Tnimoo y 1, ptrmpe hatred L%vAmWm Rwwi*orra Flow@ Re91 Ambled or a licensed F%rlds PmpbnWW EnpMr Wdohr armlolitgr andmMOfcgr mma tat Dal Product C Number, Mean, EmasumEdow 221kidgmaloRLOO hIlQ9 20AML ¢ Boors Pawn 1 Garay Wend or COmraichil Cora" Produces Pf*OW aed PM$&*"" Cono"o Loeb ON252M4 m Yes WA MIA rye 9 24 Ge, Gulf Ldr an ever qu Mn 24 Ga. Gum Lok 16&qud; Wide ova 15/32&qud; 04/122024 No Yes N/A +N/AA98.7PSF Plywood 10 24 Ga. Gum Seem Min 24 Ga. Gulf Seam 18&qud; Wide Root Panel 04/122024 No Year N/A +N/AA93.5PSF over lx4 Wood Purlins over 15/32&qua; Plywood 11 24 Ga. Gulf Seam Mn 24 Ga. Gulf Sam, 1 3/48qud; Snap Lock, 04/122024 No Yes NIA +NIAl 18&qud; Wide Rod Panel ova 1M2&qud; Plywood -108SPSF 12 28 Ga. 5V Crimp Min 28 Ga. 5V Crimp Rod Panel over 15/32&qud; 04/122024 Yes Yes N/A +NlA/ Plywood d56.5PSF 13 26 Ga. 5V Crimp Mn 26 Ga. 5V Crimp over 15/32&qud; Plywood 04/122024 No Yes NIA NW 131.PSF 14 28 Ga. 5V Crimp Mn 26 Ga. 5V Crimp Rod Pand war lx4 Wood 04/122024 No Yes N/A +N/Al Punns ever iti=quol; Plywood -156.5PSF 15 26 Ga. Calf Lok Mn 26 Ga. Gulf Lk 16&qud; Wide Roof Panel ever 04/122024 Yes Yes NIA +N/Al 15/32&qud; Plywood -181.0PSF 16 28 Ge. Gum Lok Mn 26 Ga. Gulf Lok 18&qud; Wide Rod Panel over 04/12=24 No Yes NIA +N/A/-63.5PSF 15/32&qud; Plywood 17 26 Ga. GulfPBR Mn 26 Ga. Gulf PBR Rod Panel over 15152&qud; 04FI22024 No Yes NIA -NM/ Plywood -154.7PSF Floral Department of Business & Rohmonal Regulation pap i a i Building Coda and Standards inmis Product Approval Application Detail aft 20 2MLbomm ak 220M EoararaJmMM VANOOL l idiom ldlm" EIMANO mil amo and Into Rob BaNieM lee eisamen service, LLC Mass A. Redm"m, P.E. 092=17 011029 017 07A Mil Approved (2$3) 924.6476 M08) BW1344 RobwLBaWwk4 w ioft sawer 9eaoledoMm ammtttdgM "mom mtkt m moat grit e)eampom ■t gl■■tlemtltga InHyls ouftdemAi smiad Pawn Lwr*ww $bow Lumber 03131=19 No Yes WA WA Florida Department of Business & Professional Regulation Building Codes and Standards Product Approval Application Detail Pape d2 3rAwle tear Product Nod". Numbera Name Quality CantraN Assurance HmIMNm [hoe Aderoved for Uss In HVHZ Approved for the oumid. HVHZ knwm Residents:p DMlm 18 26 Ge. GutiPBR Min 26 Ga. Gu11PBR Rod Panel over 1x4 Wood 0411211024 Yes Yes N/A -NIA/ Purlins aver 15132&qud: Plywood -151.7PSF 19 26 Ge, GulfPSR Mn 26 Ga. GuI1PBR war 1542&qud; Plywood 00=024 Yes Yes N/A +N/AI -154.7PSF 20 26 Ga. GINPSR Ion 28 Ga. GVIIPBR wer ix4 Wood Pudins over 04/1=024 No Yes N/A +N/Al 15/32&qud; Plywood -151.7PSF 21 26 Gal. G.I1Rlb Min 26 Ga. GuIMRrb over lx4 Wood Punlns over 04/12/2024 No Yes N/A -NIA/ 15132&qud; Plywood -I64.3PSF 22 26 Ga. GuffRib Mn 26 Ga. GORR, over 15/32&qud; Plywood 04/122024 No Yes N/A +N/Al 23 26 Ga. GuIBiiib Mn 26 Ga. Gu11Rib ever 15/32&qud; Plywood 04/12/2024 Yes Yes N/A +159.2PSF N/A/ 24 26 Ga. Gu11Rib Mn 26 Ga. Gu11Rib oar Us Wooed Punns over 04/122024 Yes Yes N/A -1159.2PSF N/Af 15132&qud; Plywood -164.2PSF 25 29 Ga. GumRib Mrs 29 Ge. GuMUb over Us Wood Pudins over 04/122024 No Yes N/A -NIA] 15f32&qud; Plywood -123.5PSF 26 29 Ga. GulBilb Min 29 Ga. GuRRib over 151J2&qud; Plywood 04/122024 No Yes N/A +N/Al -146.DPSF 27 29 Ga. GumUb ern 29 Ga. GuNRlb over ix4 Wood Purlins over 04/122M4 No Yes N/A +N/A( 7/16&qud; O.S.B. -101.OPSF 28 29 Ga, Gul04ib Mn 29 Ga. Gefiflb over 7/16&qud; O.S.B. 04/122024 No Yes N/A +N/A( -116.OPSF search Criteria Code Verslm: 2017 FL e: 11651 Application Type: ALL Product Manufazmrer. ALL Category: ALL subcategory: ALL Applic"lon status: ALL Compliance Masnod: ALL Quality Assura+ce entity Contract Expired: ALL Product Model, Number or Name: ALL Product Descmption: ALL Approved for us. In HVHZ: ALL Approved far use outside HVHZ: ALL Impact Resistant: ALL De"gen Rsssure: ALL Dam From: ALL Dee To: ALL N U CL Q 0 O C .� ICU U �- f 0 0 0 o Qi ICU OCU CU LL O .� E ^` W Q `V e0 0 .- `/�^'� vJ Q u FFA FFA r ■ eeee� (D C: O -4--1 CU ■ e� Cn O CD O L CU a- C U O V ICU V/ V cW G Q Z Z Q J SHEET NO. PA 1.3 ( vj-� v N �(V)r y